1 LaserRobot Controller s User Manual Hotline: sales@empower.cn Add: 1500xinfei Road No.72, Shanghai, China
2 Version: V1.0 Date: 2017/12/22 Historical Version: Historical Version Date of Relase V /12/22 Brief description of alteration Establish LaserRobot Controller s User Manual Editor Date of Edit Reviewer Date of Review Luyuan 2017/12/13 Alex LI 2017/12/22 V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 1 19
3 Index Explanation of schematic diagram of various parts...3 Explanation of operating handle...4 Explanation of connector of controller...5 Bright dipping sequential control...7 Setting of frequency and duty ratio...8 Explanation of signal lamp of controller...9 HMI Direction for use Introduction Main interface Control interface Parameter setting interface Digital signal monitoring interface Analog signal monitoring interface Historical alarm interface Troubleshooting of Laser V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 2 19
4 Explanation of schematic diagram of various parts Emergency stop Main switch Touch screen Fig Schematic diagram of panel of Laser controller Emergency-stop signal: When pressing the button of the panel of the controller emergency stop, the Laser and water-cooled machine are power off. When loosing the emergency stop button, if the buttons of the Laser and water-cooled machine are not turned off, then the Laser and water-cooled machine will be powered on once again. Rotary switch of the main switch: open/close the power source of controller. HMI interface: operation interface of Laser-Robot system. V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 3 19
5 Explanation of operating handle The operating handle is composed of 3 signals: emergency-stop signal, starting signal (green), suspension signal (red). Emergency-stop signal: consistent with the role of emergency-stop signal of the panel. Starting signal: After pressing the starting button, the system will output the starting signal. The time of duration is 2 seconds and then it is turned off. Suspension signal: After pressing the suspension button, the system will output the suspension signal. The time of duration is 2 seconds and then it is turned off. Note: The starting button and the suspension button are both triggered type. V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 4 19
6 Explanation of connector of controller V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 5 19
7 V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 6 19
8 Bright dipping sequential control When FREQUENCY_OUT and DUTY_OUT are output at the same time, the Laser will emit light at this time. The sequence figure is shown in Figure 4.1. Fig Bright dipping sequence of the Laser V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 7 19
9 Setting of frequency and duty ratio The setting of frequency and duty ratio of the Laser is controlled by the robot's analog output voltage. The voltage range of the robot s output analog is 0 ~ 10V. According to the calculation formula of analog quantity of board card, get the corresponding frequency and duty ratio of input analog voltage. The specific algorithm is as follows: Frequency: =20000* (Set frequency analog quantity of robot/2200); Duty ratio: =(Set frequency analog quantity of robot//2200)*100 Note: the setting number of analog quantity of Fanuc robot is 2200, the voltage of the corresponding analog quantity is 10V. V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 8 19
10 Explanation of signal lamp of controller The controller is equipped with three color lamps: yellow, green, red. Yellow lamp: When the rotary switch of the main switch is set to ON, the lamp will be on when the system is powered on normally. Red lamp: When the Laser emits light, the red light will be on. Rd lamp: when the Laser reports an error, the lamp will be flash, and the time interval is 1 second. If it does not report an error, the lamp will be off. V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 9 19
11 HMI Direction for use 7.1 Introduction HMI consists of 6 basic interfaces: main interface, control interface, parameter interface, digital quantity monitoring interface, analog quantity monitoring interface, historical alarm interface. Note: there are 6 buttons at the bottom of each interface. The functions of the keys are to switch the interfaces. For example, when the "Parameter" button is pressed, it goes into the parameter setting interface at this time. 7.2 Main interface Main interface is the default interface for the system to boot up, as shown in Figure 7.2.1: Fig Main interface V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 10 19
12 7.3 Control interface Control interface is composed of 4 parts, respectively: System Status Monitor Status Power Supply and Control Panel, as shown in Figure 7.3.1: The Laser-Robot system has three states: system readiness, system operation, and system error. When the Laser-Robot system does not report any errors, the Ready indicator light will be lit up, indicating that the system is in a ready state. On the contrary, if the system has any alarm, the Ready indicator light will go out. When the Laser-Robot system is in the state of light extraction cutting, the Run indicator light will be lit up; conversely, it goes out. Note: When the Laser-Robot system has an abnormal alarm, the Error indicator is lit up. When the system alarm disappears, the Error indicator goes out. Monitor Status mainly monitors the water flow of the water-cooling machine and the light-out power, frequency and duty ratio of the Laser. Note: when the Laser-Robot system starts the function of water flow monitoring, it is able to monitor the water flow of the water-cooling machine in the Control interface. When the monitoring function of water flow is not started, the feedback value is 0V. The power supply of water-cooling machine, Laser and red light power supply all have Laser- Robot system control, respectively corresponding to the Chiller, Laser, and GuideLight buttons in the PowerSupply options. That is: Chiller: power-on switch of water-cooling machine; Laser: power-on switch of Laser; GuideLight: power-on switch of red light power supply. Laser-Robot system can conduct internal control and external I/O signal control. It is the internal control key in Control Panel of Control interface. Laser Enable: control the Enable of the Laser ON/OFF Laser On: control the light-out of the Laser ON/OFF Gas On: control the magnetic valve in the controller ON/OFF Reset: clear the system alarm. V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 11 19
13 Note: 1. if the system is in the external I/O signal control state, then it is invalid to press "Laser Enable" and other keys; 2. except that the "Reset" button is triggered type, all the other buttons are maintained type. Fig Control interface 7.4 Parameter setting interface The parameter interface is composed of the laser parameter and system parameter, as shown in Figure as below: V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 12 19
14 Fig Parameter setting interface Laser Prameters includes the frequency of the laser, the Duty ratio and the setting of the lightout time, and the specific setting range is as follows: Laser Frequency: the range is between 0~20000, unit: Hz Laser Duty: the range is between 0~100,unit: % Laser Time: the range is between 0~60000, unit: ms Note: The laser parameters set are invalid under the external I/O signal control mode and are effective only under internal control. System Prameters include system control mode, traffic monitoring function, buzzer function and anti-collision function setting. External Control: external I/O signal control. Water Flow Control: flow monitoring function of water-cooling machine, when this function is enabled, the Laser-Robot system will monitor the water flow in the water-cooling machine. V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 13 19
15 Buzzer Control: Alarm buzzing function. When the function is enabled, the buzzer is sounded when the Laser-Robot system is in an abnormal alarm state. Collision Control: Cutting head anti-collision function. When the function is enabled, the cutting head is disconnected after the transverse collision, the alarm signal is output to the robot to stop the robot. Note: After setting the parameters well, you must click the "Save" button. Otherwise, the data will not be sent to the system. 7.5 Digital signal monitoring interface Fig Digital quantity monitoring interface Digital quantity monitoring interface can monitor all the input and output statuses of digital quantity in the current system, as shown in Figure The detailed introduction of signal is seen in the following table. V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 14 19
16 Signal Name Handle Emergency Handle Start Handle Stop Laser Enable Laser On Gas On Reset Collision Digital Input Instruction Emergency-stop signal input of operating handle Starting signal input of operating handle Suspension signal input of operating handle Enable signal input of external laser External light-opening signal input External gas-opening signal input External reset signal input Input of the laser head collides the signal. When the signal is high level, it suggests the collision of the laser head; when the signal is low level, it suggests the collision of the laser head. If the anti-collision function is not enabled, the signal is low level. Digital Monitor Signal Name Red Light Green Light Laser Inter Lock Solenoid Valve Open Chiller Power Laser Power System Alarm Emergency Stop V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right Digital Output Instruction When the Laser-Robot system gives an alarm, output the high level signal every 1S When the Laser-Robot system is in the state of light-out, output the high level signal When inputting the laser enable signal under the control of external I/O signal or pressing the laser enable button under internal control, output the high level signal. When inputting the gas-opening signal under the control of external I/O signal or pressing the gas-opening button under internal control, output the high level signal. After the water-cooling machine is powered on, output the high level signal After the laser is powered on, output the high level signal When the Laser-Robot system is in the state of abnormal alarm, output the high level signal When pressing the emergencystop signal externally, output the high level signal Laser Signal input of too high Start When the operating handling
17 TempOver temperature of the laser presses the starting button, output the high level signal, lasting 2 seconds Laser Fault Safety Door Signal input of errorreporting signal of the laser Signal input of switches of controller Stop Buzzer Reserved Not used yet Reserved Not used yet Reserved Not used yet Reserved Not used yet Reserved Not used yet Reserved Not used yet Reserved Not used yet Reserved Not used yet Reserved Not used yet Reserved Not used yet When the operating handling presses the stop button, output the high level signal, lasting 2 seconds When starting the buzzing function and the Laser-Robot system is in the state of abnormal alarm, output the high level signal 7.6 Analog signal monitoring interface Analog signal monitoring interface can monitor the input and output voltage values of all analog quantity in the current system, as shown in Fig Analog quantity monitoring interface V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 16 19
18 Laser Frequency: refers to the output voltage set by the robot. Laser Duty: refers to the output Duty ratio voltage set by the robot. Water Flow: refers to the analog voltage value reflected by the water-cooling machine. Guide Light Power: When the red light power is turned on in the Control interface, the 5V voltage is output at this time, and vice versa is 0V. FolwMeter Power: When the flow feedback function is started, the 10V power is output at this time, and vice versa is 0V. 7.7 Historical alarm interface The alarm interface is mainly to display the historical alarm. When the Laser-Robot system gives an alarm, the alarm number, alarm time, alarm information, current alarm value as well as other information will be displayed. The "Up" and "Down" in the interface are to review the historical alarms before and after the time; Refresh is to refresh the historical alarm, as shown in Figure 7.7.1: Fig Alarm interface V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 17 19
19 Troubleshooting of Laser Alarm 1: Laser non-enable alarm Reasons: 1. system input of laser non-enable under the external control mode; 2. not press the laser enable button Processing method: 1. it is OK by externally inputting enable signal. 2. it is OK by pressing the "Laser Enable" button in the control interface. Alarm 2: emergency stop alarm Reasons: pressed the emergency stop button of the panel of the controller of the emergency stop button of operating handle. Processing method: Loosen the emergency stop buttons of control penal and operating handle. Alarm 3: Setting errors of laser parameters Reasons: Emit laser light when the light-out time under the internal control is set to be 0. Processing method: Reset the laser light-out time, and it is OK when the time is more than 0. Alarm 4: flow alarm of water-cooling machine. Reasons: 1. the flow of water-cooling machine is insufficient or exceeds the maximum value of the laser flow; 2. not connect the flow meter cable of the water-cooling machine and the flow feedback function is enabled. Processing method: 1. Manually adjust the outlet valve and adjust the flow of water to the specified range of the laser. When the flow is in the specified range, the alarm indicator is extinguished at this time. (red light is extinguished); 2. close the function of flow monitoring. Note: The range of water flow between L/min is reasonable. Alarm 5: the temperature of the laser is too high. Reasons: when the air pressure of the internal pressurized gas of the laser is insufficient, the V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 18 19
20 laser will give an alarm. Processing method: check whether the internal pressurized protective gas is connected and whether the air pressure meets the requirements of the laser. The normal range is between : 0.1bar- 0.3bar. Alarm 6: the laser reports an error Reasons: when the flow of the water-cooling machine is insufficient or too large Solution: Manually adjust the outlet valve and adjust the flow of water to the specified range of the laser. Alarm 7: The security door is not closed Reasons: the controller is in an open state. Solution: it is OK by closing the board in front of the controller. Note: 1. In case any kind of alarm occurs, the red light of the controller will flicker and be lit up; 2. For security consideration, when any kind of alarm occurs, the laser will not give out light. V1.0 Shanghai Empower Technologies Co., Ltd. Copy Right 19 19
Sequence of operation
Sequence of operation IPS 4000 secondary variable speed control File No: 90.96 Date: february 21, 2013 Supersedes: new Date: new sequence of operation ips 4000 2 list of abbreviations: adj: Field Adjustable
More informationCódigo de Erros Split Piso Teto
Código de Erros Split Piso Teto No. Type Description Flash Blink Code Note 1 Failure Indoor temp. sensor testing port warning Timer led blinks on 1Hz frequency E2 2 Failure 3 Failure 4 Failure Evap. temp.
More informationSERVICE MANUAL REFRIGERATION
SERVICE MANUAL REFRIGERATION Electrolux Home Products S.p.A. Spares Operations Italy Corso lino Zanussi, 30 I - 33080 Porcia (PN) Fax +39 0434 394096 S.O.I. Edition: 10.2006 Publication no. 599 38 38-50
More informationGas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1
Gas Safety Products Merlin CT1650+ Gas Interlock System Installation, operating and maintenance 09/05/2016 S&S Northern Ltd 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel
More informationE-16 Main Engine Remote Control System
Guideline No.E-16 (201510) E-16 Main Engine Remote Control System Issued date: 20 October, 2015 China Classification Society Foreword This Guide is a part of CCS Rules, which contains technical requirements,
More informationbeyond 260VAC, then LED shows. In these two kinds of situation, the system will not go into normal operation.
Ⅰ. Overview of the Panel The Manual of KL8500 Fig. 1.The panel plan of 9 buttons AUX O3 3 4 1 2 1 2 Fig. 2.The installation plan of 9 buttons (200*100mm) Ⅱ.The function summary 1. Plug-and-play mode is
More informationInstallation & Operating Instructions
FH-RT Wireless Room Thermostat FH-BU Wireless Base Unit Installation & Operating Instructions Specification Base unit (230 V) Order Code: Primary voltage: Secondary voltage: Outputs 1-6: Outputs 7-8: 088H011901
More informationSERVICE MANUAL REFRIGERATION
SERVICE MANUAL REFRIGERATION ELECTROLUX HOME PRODUCTS S.p.A. Publication no. Spares Operations Italy 599 37 75-07 Corso Lino Zanussi, 30 060824 I - 33080 PORCIA / PN (ITALY) ITZ/SERVICE/AA Fax +39 0434
More informationPF1000 CONTROLLER. for the. Heateflex Corporation 405 E. Santa Clara St. Arcadia, CA TEL: (626) ; FAX: (626)
PF1000 CONTROLLER for the AQUARIUS I/II DEIONIZED WATER HEATING SYSTEM Heateflex Corporation 405 E. Santa Clara St. TEL: (626)599-8566; FAX: (626)599-9567 Rev. 07 10/19/10, (PF1000) 1 2 TABLE OF CONTENTS
More informationOperation & Maintenance Manual
Operation & Maintenance Manual for Model 2100 Fire+Smoke systems from Smoke Guard, Inc. 287 N. Maple Grove - Boise, ID 83704 Phone: (800) 574-0330 Fax: (208) 639-7851 E-Mail: info@smokeguard.com Website:
More informationM2500 Engine Controller Installation Manual
M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...
More informationCT2211 Aerosol Leak Detection System
User Manual QCL-MAN -CT2211-Aerosol-Leak-Detection-System, Rev F October 2015 CT2211 Aerosol Leak Detection System Preface All possible care has been taken in the preparation of this publication, but Cascade
More informationINSTRUCTION MANUAL FOR
INSTRUCTION MANUAL FOR Cool Block The 1st Edition Yamato Scientific Co.,, Ltd. 2-1-6, Nihonbashi Honcho, Chuo-ku Tokyo 103-8432 JAPAN Congratulations on your selection of Yamato Scientific s Cool Block
More informationHOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4
HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4 INTRODUCTION Thank you for purchasing the Hokkim Integrated Automatic Mains Failure Control Board model HAMF- 8 or HAMF-4. We shall
More informationClock Radio AJ100. User manual
Clock Radio AJ100 User manual 1 1 2 5 6 3 4 7 8 9! @ # $ % 0 ^ 2 3 4 English SUPPLIED ACCESSORIES 1 X AC 7.5V adapter (Input: 220-230V ~ 50Hz 30mA, Output: 7.5V 250mA) TOP AND FRONT PANEL (See 1) 1 REPEAT
More informationQD-ENG-68 Controller for Thermoelectric Thermal Management
INSTALLING THE CONTROLLER QD-ENG-68 Controller for Thermoelectric Thermal Management The Ice Qube TMS controller is shipped complete with mounting hardware and electrical cables for easy installation.
More informationUseful Notes: TDM Type S2
Useful Notes: TDM Type S2 Copyright F. M. Spowart These notes are uncontrolled and NOT Network Rail endorsed, they are for information and guidance ONLY, NOT for testing or commissioning purposes. TDM
More informationGas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016
Gas Safety Products Installation, operating and maintenance 05/10/2016 American Gas Safety LLC 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting.... 3 2.2 Mains Supply...
More informationTechnical Manual. Level Alarm Unit CARLA & WIDS
CARLA & WIDS Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CARLA for Tankers Cargo Tanks
More informationReplaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge
Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays
More informationDIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)
DIESEL ENGINE CONTROL UNIT DCU 205 - USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) 64 84 52 00 Fax: (+47) 64 84 52 12 office@auto-maskin.no - 1 - TABLE OF CONTENTS 1. INTRODUCTION TO THE DCU 205...4
More informationSECURIT 700L USER MANUAL
SECURIT 700L USER MANUAL C & K Systems Ltd 6/12/95 Securit 700L User instructions This manual will give you all the information you need to operate and control the Securit 700L Control Panel. This manual
More informationWestken information manuals and technical assistance General Manual for Masterweld 15 Timer control system.
Instruction and programming/setup manual for the resistance welding "Masterweld 15" welding control timer systems. ( 08C Seam welding control) (02E Spot / Proj with Highlift welding control). ***Important
More informationHYDROPONICS AND GREEN HOUSE CONTROLLER MODEL HGC-003 OWNER'S MANUAL FAN MAX TEMPERATURE LAMP DURATION FAN MAX HUMIDITY PUMP INTERVAL DECREASE
HYDROPONICS AND GREEN HOUSE CONTROLLER MODEL HGC-003 OWNER'S MANUAL REMOTE FLOOD AM PM PHOTO F rh PPM TEMPERATURE HUMIDITY SELECT RUN LAMP START FAN MAX TEMPERATURE LAMP DURATION FAN MAX HUMIDITY PUMP
More informationKNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )
Product definition KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no 2343 00) Art. no 2343 00 Page 1 of 22 Product definition Table of contents 1 Product definition... 3 1.1 Product catalogue...
More informationUsing the Dome On/Off Plug-In Switch with SmartThings. Table of Contents
+ Using the Dome On/Off Plug-In Switch with SmartThings 773-794-1300 support@domeha.com www.domeha.com Table of Contents Installing the Device Handler 2 Main Page 3 Settings Page 4 Turn on a Lamp When
More informationHennecke description of day tanks and metering equipment used in conjunction with Rotamats supplied to Trane (Vidalia, GA)
Hennecke description of day tanks and metering equipment used in conjunction with Rotamats supplied to Trane (Vidalia, GA) 2013-09-16 Tank Station for Coil and Fan Door Production Item B ITEM NO. DESCRIPTION
More informationREPAIR INSTRUCTIONS. TUMBLE DRYER Vented WTA34.. / WTA35..
REPAIR INSTRUCTIONS TUMLE DRYER Vented WTA34.. / WTA35.. I. SAFETY INFORMATION Page 1 II. OPERATION Page 1 III. DESCRIPTION OF FUNCTION / TECHNICAL INFORMATION Page 2 IV. CONSUMPTION RATES / ENERGY REQUIREMENT
More informationSERVICE MANUAL COOKERS
SERVICE MANUAL COOKERS Electrolux Distriparts Muggenhofer Straße 135 D-90429 Nürnberg Germany Publ.-Nr.: 599 522 770 685 EN Ovens Compact Range Steam Fax +49 (0)911 323 1022 DGS-TDS-N Edition: 03.08 Table
More informationService Documentation
After Sales Service International Service Manual No. 16/2010 Service Documentation LWL/KDT-baj/30.06.10 Appliance Documentation GKv 4310 / 4360 from Index 20 Commercial refrigerator, ventilated GKv 5730
More informationrecord.group User manual record FlipFlow Triple automatic door systems this is record! record your global partner for entrance solutions
record your global partner for entrance solutions User manual record FlipFlow Triple your global partner for entrance solutions record.group automatic door systems this is record! Table of contents Table
More informationGreat Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO
Great Britain en Installation, user and service manual Control panel HMI Gas 310/610 ECO PRO Dear Customer, Thank you very much for buying this appliance. Please read through the manual carefully before
More informationColour Observation System
FAR < > NEAR Colour Observation system talk action menu _ + auto next FAR < > NEAR Colour Observation Monitor Colour Observation Monitor English Colour Observation System Table of contents Page Introduction...3
More informationFB10000 Error Messages Troubleshooting
Error ID: 66300 - UV UV System Active Alarm (UV will shut down). 66300 UV System Active Alarm (UV will shut down). Tap Get Ready. For more details open the Troubleshooting guide This UV error
More informationSingle Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual
We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More information3. Proper use. 4. Function. 1. Product characteristics. 2. Safety. Function description. Channel A light. Motion detector
307021 3. Proper use EN Motion detector themova P360-100 UP WH 1030600 themova P360-100 UP GR 1030601 The motion detector is intended for interior. The motion detector is eclusively intended for the use
More informationService Manual NRC83 (-DV, -OD) NRC98 (-DV, -OD) NRC1111/NCC1991(-DV,-OD) NR981/NC1991(-DVC,-OD,-SV) NR83-DVC. Rev: October, 2012.
NC8 (-DV, -OD) NC98 (-DV, -OD) NC/NCC99(-DV,-OD) N98/NC99(-DVC,-OD,-SV) N8-DVC Service Manual efer to this manual whenever performing service or maintenance on this appliance. This manual will be used
More informationUsing the Dome Motion Detector with SmartThings. Table of Contents
+ Using the Dome Motion Detector with SmartThings 773-794-1300 support@domeha.com www.domeha.com Table of Contents Installing the Device Handler 2 Main Page 3 Settings Page 4 Get a Notification When Motion
More information7. ON/OFF Controller (CZ-ANC2)
Control of WAY SYSTEM. / Controller (CZ-ANC). How to Use the / Controller Functions of buttons A : / button C : All button B : All button A: / button Press this to start up or stop an individual air conditioner.
More informationParts introduction FRONT BACK
Lando Industrial Water Chillers installation instructions Thank you for using the machine from Shenzhen Lando Technology Industrial Co.,Ltd.. Please read the installation instructions carefully before
More informationProduct Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1
Gas Safety Products Merlin GDP2 Installation, operating and maintenance 23/08/2016 S&S Northern Ltd 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting..... 3 2.2 Mains
More informationWith Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.
MatiGard User Guide 02 Menu Feature-------------------------------------------------------------- 05 Overviews---------------------------------------------------------- 07 Read Before Using-----------------------------------------------
More informationIMR 5000 IMR 400. CEMS Operating Manual IMR USA S/N: Sample IMR Sensors Inside IMR 400. Gas Dryer Inside. IMR Environmental Equipment Inc.
CEMS Operating Manual IMR USA S/N: Sample IMR 5000 IMR 400 IMR 400 IMR 5000 Measure MESURE PURGE Purge CALIBRATE Calibrate OFF OFF RESET Measure ON ON Calibrate RESET PUMP Gas Dryer Inside PUMP Sensors
More informationProStar 325 UV-Vis Detector
Varian, Inc. 2700 Mitchell Drive Walnut Creek, CA 94598-1675/USA Star Chromatography Workstation Version 6 ProStar 325 UV-Vis Detector Control Software Varian, Inc. 2004 Printed in U.S.A. 03-914732-01:Rev.
More informationDUAL MONITORED INPUT/OUTPUT UNIT BN-305
DUAL MONITORED INPUT/OUTPUT UNIT BN-30 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection
More informationMillennium Xtra. Millennium ATMA setup and configuration guide. May Millennium Group, Inc.
Millennium Xtra Millennium ATMA setup and configuration guide May 16 2017 Millennium Group, Inc. 16 Tech Circle Natick, MA 01760 P: 508-655-1340 F: 508-651-2902 Millennium ATMA setup and configuration
More informationHalton SAFE / 7.14 user guide and installation instructions
Halton SAFE / 7.14 user guide and installation instructions VERIFIED SOLUTIONS BY H A LTO N Enabling Wellbeing Table of contents 1 System description 3 2 User Accounts 4 3 Main menu 7 3.1 Main menu - Change
More informationSigma XT. Extinguishant Control Panel. User Manual Man-1091 Issue 03 October 2009 (K11031M2, K11031F2)
Sigma XT Extinguishant Control Panel (K11031M2, K11031F2) User Manual Man-1091 Issue 03 October 2009 Fire alarm condition General fire indicator lights and zonal fire indicators flash. Buzzer sounds urgently.
More informationOriginal operating instructions Safety switch with guard locking AC901S AC902S
Original operating instructions Safety switch with guard locking AC901S AC902S 7390914/03 01/2017 Contents 1 Preliminary note...4 1.1 Explanation of symbols...4 2 Safety instructions...4 3 Items supplied...5
More informationPart. Test System Weekly See Watch ~Test. Points
Part 1. Test System Weekly See Watch ~Test Points 2. 3. 4. 5. 6. 7. 8. Turn System Off Enter your passcode to turn the system off and silence alarms. Turn System All On Press 9 Exit Delay begins If Error
More informationDual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual
We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More information3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector
EN Motion detector themova S360-101 DE WH 1030565 themova S360-101 DE GR 1030566 themova S360-101 AP WH 1030555 themova S360-101 AP GR 1030556 1. Product characteristics 307067 Passive infra-red motion
More informationGas Safety Products. Installation, operating and maintenance 28/10/2015. Merlin CT1250 Gas Interlock System. S&S Northern Ltd 1
Gas Safety Products Merlin CT1250 Gas Interlock System Installation, operating and maintenance 28/10/2015 S&S Northern Ltd 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting.....
More informationSimplex Panel Interface Guide
Simplex Panel Interface Guide February 2016 SATEON Software Integrations Simplex Panel Interface Guide Issue 1.0, released February 2016 Disclaimer Copyright 2016, Grosvenor Technology. All rights reserved.
More information900mm Island Canopy Manual
900mm Island Canopy Manual MODEL ICF9BLS Installation and Operation CANOPY INSTALLATION AND OPERATION MANUAL Dear Customer, We thank you for choosing this quality appliance and hope you enjoy many years
More informationMounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller
TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller Mounting and Operating Instructions Electronics from SAMSON EB 5610 EN Firmware version 1.40 Edition December 2014 Controller
More informationContents. Glossary
Contents Glossary ------------------------------------------------------------------------------------------------------ 6 1. Introduction to the IDS 1632 -------------------------------------------------------------
More informationAS DIGITAL FIRE PUMP CONTROLLER
AS 2941-2013 DIGITAL FIRE PUMP CONTROLLER COMPLIANT WITH AS2941-2013 CLAUSES 9.4.1 9.4.22 OPERATION INSTRUCTIONS New South Wales Unit 2/1040 Canley Vale Road Wetherill Park NSW 2164 Ph: +61 2 9757 5800
More informationUsing the Dome Leak Sensor with SmartThings. Table of Contents
+ Using the Dome Leak Sensor with SmartThings 773-794-1300 support@domeha.com www.domeha.com Table of Contents Installing the Device Handler 2 Main Page 3 Settings Page 4 Get a Notification When A Leak
More informationMANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX
MANUAL OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX 1) Technical Specifications: (100VA, 200VA, 300VA) 2) Introduction 3) Construction 4) Operation and maintenance a) Operating Procedure b)
More informationIntelligent cascading kit
Technical Service Instruction Intelligent cascading kit Kit components: Cascading cable (2X) 6720811759 / 238-51036-00A (2014/05) Table of contents Table of contents 1 Key to symbols and safety instructions............
More information1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6
307214 1103107701 EN Presence detector theronda S360-101 DE WH 2080565 theronda S360-101 DE GR 2080566 theronda S360-101 AP WH 2080555 theronda S360-101 AP GR 2080556 1. Product characteristics 4 2. Safety
More informationIntelligent Swing Gate Turnstile Operating Manual CPW-322CS
Intelligent Swing Gate Turnstile Operating Manual CPW-322CS C O N T E N T S 1. General Descriptions...1 2. Definitions... 1 2.1 Swing Gate Turnstile... 1 2.2 Passing Modes... 2 3. Safety Precautions...3
More informationMotion detector themova P360 KNX UP WH themova P360 KNX UP GR
307079 EN Motion detector themova P360 KNX UP WH 1039600 themova P360 KNX UP GR 1039601 1. Product characteristics 4 2. Safety 5 3. Proper use 6 4. Function 6 5. Detection area 10 6. Installation 13 7.
More informationIDS816 User Manual H Issued January 2009
1 Contents Glossary-------------------------------------------------------------------------------------------------------------------6 1. Introduction to the IDS 816---------------------------------------------------------------------------7
More informationInstallation and Operation Guide EXTERNAL SIREN
EXTERNAL SIREN CTENTS 01. INTRODUCTI 03 02. INSTALLATI ATI 04 2.1. Installing the External Siren on the Active SmartHome 04 2.2. Power Supply 07 2.3. Mounting the External Siren 08 03. OPERATI 11 3.1.
More informationSmoke Detector and Siren. Manual
Smoke Detector and Siren Manual 004001 Smoke Detector and Siren Manual Quick Start... 2 Product Description... 2 Installation Guidelines... 3 Behavior within the Z-Wave Network... 3 Operating the Device...
More informationWatchguard WGAP864 User Manual
Watchguard WGAP864 User Manual v1.0 Issued September 2016 1 2 Table of Contents Glossary... 5 1. Introduction to your Watchguard WGAP864... 6 2. Before Operating your Alarm System... 6 3. Understanding
More informationMonitor Alarms and Events
This chapter contains the following topics: What Are Alarms and Events?, page 1 How are Alarms and Events Created and Updated?, page 2 Find and View Alarms, page 3 Set Alarm and Event Management Preferences,
More informationPremier Hazard STC Instructions
PREMIER HAZARD Ltd Bessingby Industrial Estate Bridlington YO16 4SJ Tel: +44 (0) 113 239 1111 Fax: +44 (0) 113 239 1131 www.premierhazard.co.uk info@premierhazard.co.uk Premier Hazard STC Instructions
More informationUSER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel
USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel PU SENS 01 CONTENTS Safety requirements... 3 Purpose... 4 Technical data... 4 Overall dimensions [mm]... 4 Mounting and set-up... 5
More informationDual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual
We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationExercise 8. Controlling a Batch Mixing Process EXERCISE OBJECTIVE
Exercise 8 Controlling a Batch Mixing Process EXERCISE OBJECTIVE To create a ladder program for controlling a batch mixing process. To test program operation through the completion of verification steps.
More informationI/A Series 716C 1/16 DIN Temperature Controller
Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of
More informationCONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3
CONTENTS Installation Precautions... 1 Chapter 1 Product Introduction... 2 Chapter 2 Technical Specifications... 3 2.1 Electrical Specifications... 3 2.2 Communication Loop Parameters... 3 2.3 Dimensions...
More informationBRS Mechanically-Agitated BioReactor MA 100. Quick Reference Guide Ver2.0
BRS Mechanically-Agitated BioReactor MA 100 Quick Reference Guide Ver2.0 Manufacturer: BioReactor Sciences 1150 Home Place Drive Lawrenceville, GA 30043 USA Phone: 404.307.7100 Email: info@bioreactorsciences.com
More informationGas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:
Gas Safety Products Merlin 1500S Gas Interlock System Installation, operating and maintenance Rev: 03 Date: 08-01-18 1 Table of contents 1 General information... 3 2 Installation... 3 2.1 Panel Mounting....
More informationUser Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.
User Manual for model FLOWMAX-90 Condensing water heater 85,000 BTU WARNING If the information in these instructions is not followed exactly, a fire or explosion may result, causing property damage, personal
More informationSC-500 ENGINEER S MANUAL
R SC-500 ENGINEER S MANUAL 4009500 No.E359-00 PREFACE This Engineer s Manual is written for the technical personnel who are responsible for the service and maintenance of the machine. The Instruction Manual
More informationOzonated Water System
Ozonated Water System AirTreee Ozone Technology Co. Http: //www.airtree.com E-mail: market@airtree.com Tel: 886-2-2693-2663 1. Ozonated water system The Ozonated water system is a skid-mounted and plug-
More informationEC300W. Evaporative Air Cooler OWNERS MANUAL. Read and save these instructions.
EC300W Evaporative Air Cooler OWNERS MANUAL Read and save these instructions. 2 Trust should be earned and we will earn yours. Customer happiness is the focus of our business. From the factory to the warehouse,
More informationElectronic timeswitch
Electronic timeswitch RWB1007 To control combination boilers and single zone applications together with the appropriate thermostat. Easy-to-read backlit display Time programming 7-day 2/3 ON/OFFs Advance
More informationFL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com
FL500 Modbus Communication Operating Manual Order No.: 10193214/00 MSAsafety.com 1000 Cranberry Woods Drive Cranberry Township, PA 16066 A Phone 1-800-MSA-2222 Fax 1-800-967-0398 For your local MSA contacts
More informationFLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING
FLAME115 INFRARED HEATER SERVICE MANUAL INDEX 1. CONTROLS AND COMPONENTS 2. FLAME CONTROL CYCLES 3. MAINTENANCE SCHEDULE 4. TROUBLESHOOTING GUIDE 5. REPAIR PROCEDURES 1. FAN MOTOR ASSEMBLY 2. FUEL FILTER
More informationDigital Electronic Thermostat With RF
Digital Electronic Thermostat With RF Instruction Manual Model No RT300RF PRODUCT COMPLIANCE This product complies with the essential requirements of the following EC Directives: Electro-Magnetic Compatibility
More informationTri-Stack Smart System
Tri-Stack Smart System TM Notes & Warnings - The protection provided by this equipment may be impaired if it is not used in the manner specified herein. - Ensure all wiring meets applicable national and
More informationMODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL
TRACON MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL TABLE OF CONTENTS FPT 130 Overview... 2 Installation... 3 Power Source and Load Connections... 4 Temperature Sensor... 5 External
More informationHR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor
Section 1 General Description The is a microwave motion sensor for activating automatic industrial doors. Features include a speed selectable switch that makes the unit capable of detecting pedestrians
More informationMR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack
Master Catalog 125 Temperature Controls Section A Product/Technical Bulletin Issue Date 1098 MR4PMUHV Electronic Temperature/Defrost Control with Relay Pack The MR series temperature controls are designed
More informationCat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE
Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product
More informationMOBILE CALL GSM Alarm System User s Manual
MOBILE CALL GSM Alarm System User s Manual Profile For a better understanding of this product, please read this user manual thoroughly before using it. Contents Function Introduction (3) Alarm Host Diagram
More informationCaterSense 03 & ATSC-02-xx
CaterSense 03 & ATSC-02-xx GAS SUPPLY INTER-LOCK STATION with INBUILT FAN SPEED CONTROL & CO 2 MONITORING (Optional Gas Pressure Proving) INSTALLATION and COMMISSIONING INSTRUCTIONS CS-ATSC-INST-CO2 Page
More informationEGE Manisa 70 cm BIR Carinaro 55 cm. Fabriano June Presenter Francesco Nieli
EGE Manisa 70 cm BIR Carinaro 55 cm Fabriano June 2012 Presenter Francesco Nieli Keys and Interfaces Manisa EGE key Carnaro BIR key Tiny Full interface (SQG_CL_??) Tiny SD interface (SQG_CL_??) New LED
More informationOPERATION MANUAL. Daikin Altherma indoor unit EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1
OPERATION MANUAL EKHVMRD50ABV1 EKHVMRD80ABV1 EKHVMYD50ABV1 EKHVMYD80ABV1 EKHVMRD50+80ABV1 EKHVMYD50+80ABV1 CONTENTS Page 1. Definitions... 1 2. Introduction... 2 2.1. General information... 2 2.2. Scope
More informationResidential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...
70 80 99-00-O Residential Gas Condensing Boiler ZBR//8/35/4-3A... ZWB8/35/4-3A... 70 80 993 (03/03) CA/US Operating Instructions Contents Contents Key to symbols and safety instructions............................
More informationDIGITAL LIGHT CONTROLLER
DIGITAL LIGHT CONTROLLER Manual - Model UD 0900 Modular lighting controller for 20 HPS or MH lamps Reading this manual will help you better understand the functions of your device and its potential. Keep
More informationThe Kryos LN2 Liquid Level Control & Cryogenic Temperature Control
The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control Created for Taylor-Wharton Gas Equipment By Pacer Digital Systems, Inc. INTRODUCTION... 4 TEXT FORMAT NOTATION... 4 SYSTEM COMPONENTS...
More informationBENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.
BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice. via Florida Z.I. Valtesino - 63013 GROTTAMMARE (AP) - ITALY Installation and Quick guide: DUAL
More information2000 Series. Program Entry Guide. Control Panels
2000 Series EN Program Entry Guide Control Panels 2000 Series Program Entry Guide About This Manual EN 2 About This Manual This guide describes the programming parameters available to the 2000 Series Control
More informationDUAL MONITORED INPUT/OUTPUT UNIT BN-305-2
DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection
More information