LX-5 FIRE DAMPER. EI 120 (ve ho i o) S EN A1:2010. Damper tightness class: 4 EN 1751:2002. Casing tightness class: C. Fulfils requirements

Size: px
Start display at page:

Download "LX-5 FIRE DAMPER. EI 120 (ve ho i o) S EN A1:2010. Damper tightness class: 4 EN 1751:2002. Casing tightness class: C. Fulfils requirements"

Transcription

1 LX5 FIRE DAPER EI 120 (ve ho i o) EN +A1:20 Damper tightness class: 4 EN 1751:2002 Casing tightness class: C Fulfils requirements 88 EN 15650:20 GOLD EDAL TP 20 ARCH 20, 20 PATENT GRANT DECIION RELATING TO P.70 in libraries of parametric libraries FUNCTION The GRYFIT LX5 fire damper is designed for buildings outfitted with a onestage evacuation scenario based on the fire affected zone separation principle. The damper meets the requirements for buildings where in the event of a fire the affected zone should be isolated from the other zones by remotely closed fire dampers, while the ventilation system should operate normally in the other zones. APPLICATION The GRYFIT LX5 fire damper is used in ventilation or air conditioning ducts passing through fire resistant partitions. It allows separation of the affected zone in the event of a fire. After closing, the fire damper preservers resistance of the fire partition. This way it protects other zones against smoke and fumes, and allows normal operation of the rest of the ventilation or air conditioning system. At normal ambient temperatures the fire damper remains open (in the standby position). In the event of a fire the LX5 blade closes and separates the fire zone (the damper blade shifts to the safety postion) Closure of the fire damper: is activated automatically by the relase of fusible link when the air temperature in the duct rises above 72 C is activated remotely by a control signal from the fire detection unit. The fire damper is closed by a return spring mechanism. Reopening of the damper (returning it to the standby position in the event it has been remotely closed) is done manually by tensioning or remotely by an actuator. In the event that the fire damper was automatically closed by the fusible link relase, the fusible link must be replaced with a new one and then the previously described actions should be performed the open the damper. Fire damper blade positions monitoring is provided by electrical microswitsches. DECRIPTION The GRYFIT LX5 fire damper consists of: rectangular casing made of galvanized steel sheet and fire resistant board, movable damper blade of fire resistant board, fire and smoke proof damper blade seal, control mechanism Fax info@dampic.se Dampic ystem AB Box otala Tel 0 Försäljningskontor tockholm Norrköping GRYFIT air handling intelligence ul. Langiewicza Konstantynów Łódzki 33 POLAND tel.: +48 (91) 2 00 fax: +48 (91) contact@gryfit.com FIRE AFETY EN 1751:2002

2 ELECTION DIENION OF FIRE DAPER WITH FLANGE CONNECTION FOR RECTANGULAR DUCT H 200 L ,85 8 3,6 4, 11 4, 11 5, 5,85 7, 17 8, ,30, 23 11,85,,85 16, 17,85, 20,85 44, ,80 4, ,80 6, 6, , ,80 11,80 12, 24,80 15,80 17,80,80 21,80 23,80,80 27,80, , ,00 7, 7,63 8, ,75 12,,75 15,50 17,,75, 24,75 27,,75,,75, 5 5, ,36 7,69 8,08 9,01 16, 12,99 15, 16, 18, 20,94 23,59,24,89,54, 36,84 39, 0 6,65 8, 16,15 17, ,,65 17,15 20,65 21, 24,15 27,65,15,65,15,65 45,15 48,65, ,85 17,80,05 20, ,30 17,,05, 27,,05,,05 44,,05 53,,05 62,,05 600,45 20,20 15, , , 21,45,95,45,,95,45 48,95 54,45 59,95 65,45,95 76,45 81, ,02 23,92 16,82 17,69,72,62,42,,96,02 45,82 51,62 57,42 63, 69,02 74,82 80,62 86, , 15,60 18,85,83,,,85,,30 44,85 51, 57,85,,85 77, 83,85, 96,85 800, 18,00 21,75,88,50, 36,75 44,, ,75 59, 66,75 74, 81,75 89, 96,75 4, 111, ,15 20, 24,65,93, 33,15,65 50,15, 47,65,15 75,65 84,15 92,65 1,15 9, ,05,80 27,,98,30,05, 56,05, 50 65, 75,05 84, 94,05 3, 1,05 10,95,20 30,45,03,,95 51,45,95 65, 53 72,45 82,95 93,45 3, ,85 27,60 33, 44, , 44,85 56,,85 71, ,,85 2, 1,85 for dimensions not listed in this table assembly in multiple arrangement of fire dampers is provided not available effective area [dm 2 ] weight [kg] Dampic ystem AB Box otala Tel 0 85 Fax info@dampic.se Försäljningskontor tockholm Norrköping

3 ELECTION DIENION OF FIRE P C Table of dimensions for brick/concrete partition wall G=1 mm (F, A, P) and light weight partition wall G=1 mm (F*, A*, P*) H x L F A G 50 H x L Hr x Lr H F 0,5,5 50,5,0 85,5 0,5 150,5 200,5 215,5 0,5 300,5 0,5 0,5 450,5 500,5,5,5 5,5 1,5 1,5 2,5 2,5 3,5 3,5 A A* DIENION OF FIRE DAPER WITH LEEVE CONNECTION FOR ROUND DUCT A P C B 50 Ø D D L i H P A B C Weight [kg] K [ ] 0,66 0, 0,51 0,44 0, 0, 0,23 0, 0,20 0, 0, 0,18 [dm 2 ] 4,0 6,2 7,0 9,0 1 20,2 30,2 33,6 4 56,2 7,2 Dampic ystem AB Box otala Tel 0 85 Fax info@dampic.se Försäljningskontor tockholm Norrköping

4 A INTALLATION OF FIRE DAPER IN PARTITION WALL LX5 DIENION AND INTALLATION ETHOD Detail A 5 1 Installation of fire dampers in partition: horizontal vertical GRANICA WUROWANIA Lr x Hr=L + x H + ortaring border ORTARING BORDER 1 Partition wall 2 Cement lime mortar* 2 inimum installation opening: Concrete or brick walls Lr x Hr = (L + ) x (H + ) ortaring border: is clearly marked by the label on the casing, damper blade should align with the center line of the partition wall s thickness (for construction elements of 1 mm thickness) if mortaring in wall or ceiling, mortaring border marking on the fire damper must be strictly observed The GRYFIT fire damper can be installed with it s blade axis positioned horizontally as well as vertically. * Not delivered by CIAT INTALATION IN A LIGHTWEIGHT PARTITION WALL Lr x Hr = L = x H + Gypsum mortar L x H Installation of fire damper in partition: horizontal vertical inimum installation opening: Lr x Hr = (L + ) x (H + ) 1 5 ORTARING BORDER ortaring border ortaring border: is clearly marked by the label on the casing, damper blade should align with the center line of the partition wall s thickness if mortaring in wall or ceiling, mortaring border marking on the fire damper must be strictly observed The GRYFIT fire damper can be installed with it s blade axis positioned horizontally as well as vertically. FLOOR AND CEILING Floor ortaring border Ceiling Closing mechanism teel mounting brackets teel rawlplugs ORTARING BORDER ortar filing teel rawlplugs teel mounting brackets ortar filing teel mounting brackets ORTARING BORDER Closing mechanism ortaring border Dampic ystem AB Box otala Tel Fax info@dampic.se Försäljningskontor tockholm Norrköping

5 DIENION AND INTALLATION ETHOD ACCEORIE 1. Fire damper GRYFIT LX5 with fussible link: fussible link 72 C WT 72 fussible link 95 C WT Fire damper GRYFIT LX5 with microswitches icroswitch open icroswitch closed Fire damper GRYFIT LX5 with microswitches and electromagnet deenergized or impulse icroswitch open icroswitch closed 24V DC (+) 230V AC N () L1 upply voltage Power imput 24 or 48 V DC impulse 3,5 W CHARACTERITIC OF ELECTROAGNET 230 V AC impulse 5,5 VA 24 or 48 V DC deenergized 1,6 W 230 V AC deenergized 4 VA Dampic ystem AB Box otala Tel Fax info@dampic.se GRYFIT Försäljningskontor air handling intelligence tockholm ul. Langiewicza Norrköping Konstantynów 011 Łódzki 33 POLAND 00 tel.: +48 (91) 2 00 fax: +48 (91) contact@gryfit.com

6 4. Fire damper GRYFIT LX5 with actuator PARAETER FDGWT8230 FDGWT824 supply voltage [V] 230V AC 24V AC/DC power on move [W] 9,2VA 3,5W power on stand [W] 6,9VA 0,5W pening blade time actuator [s] 71s 71s close blade time spring [s] 21s 21s torque motor [Nm] 8Nm 8Nm degree of protection IP IP54 IP54 sound power level actuator db(a) 47dB(A) 47dB(A) sound power level spring db(a) db(a) db(a) 5. Fire damper GRYFIT LX5 with module E + tester TZ5 Easy aintenance ystem module guarantee quick and correct connection of the portable TZ tester that enables delivery of suitable control impulse or deenergizing of a selected voltage 24 V or 230 V, in purpose of functionality assessment during the installation work, commissioning process of the installation and during normal management of the building. Use of the E system together with the TZ tester speeds up commissioning of the installation considerably and leaves no doubt as regards to its correct performance. OPTION Rectangular flange connection Rectangular sleeve connection Round sleeve connection Detail A Detail "A" B Detail "B" H 30* H H ** R4,5 * avaiable option flange 20 mm ** flange 20 mm 2 mm Dampic ystem AB Box otala Tel 0 85 Fax info@dampic.se Försäljningskontor tockholm Norrköping

7 FOUR FIRE DAPER ARRANGED IN ULTIPLE AEBLY Installation opening THREE OR ORE FIRE DAPER ARRANGED IN VERTICAL OR HORIZONTAL ULTIPLE AEBLY Hr=Hbat. + Hbat.=(H1+H2+H3)+(iloÊç klap 1) x 65 H1 H2 H3 TWO FIRE DAPER ARRANGED IN VERTICAL OR HORIZONTAL ULTIPLE AEBLY Lr=Lbat.+ Lbat. Lr=Lbat.+ Lbat.=(L1+L2)+65 Hbat. Hr=Hbat.+ H1 H2 Hbat.=(H1+H2)+65 Hr=Hbat.+ Lbat. Lr=Lbat. + Installation opening Installation opening Installation opening Dampic ystem AB Box otala Tel Fax info@dampic.se GRYFIT Försäljningskontor air handling intelligence tockholm ul. Langiewicza Norrköping Konstantynów 011 Łódzki 33 POLAND 00 tel.: +48 (91) 2 00 fax: +48 (91) contact@gryfit.com

8 ELECTRICAL DIAGRA Electrical wiring diagram for actuator FDGWT824, FDGWT8230 ~ + N L a < 5 b < 80 Electrical wiring diagram for actuator FDGWT824 +E, FDGWT8230 +E ~ + N L E ORDER KEY Enquiry: Fire damper EI120 with rectangular flange 30 mm GRYFIT LX5 LxH=600x500 + Actuator 24/48V AC/DC FDGWT824 + odule E GRYFIT quotation: GRYFIT LX5, LxH=600x500, KP 30 + FDGWT824 + E a < 5 b < 80 L H Design changes reserved. All rights reserved. GRYFIT air handling intelligence LX5G 06. ENG Dampic ystem AB Box otala Tel 0 85 Fax info@dampic.se Försäljningskontor tockholm Norrköping

Bevent Rasch BSKC6. - Fire /06/17

Bevent Rasch BSKC6. - Fire /06/17 Bevent Rasch - Fire - BSKC6 19/06/17 Fire resistance class EI60/EI60S Sizes from 100 mm to 630 mm Prefitted safety actuator 24V or 230V Low weight Easy installation CE-marked building product according

More information

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU Type FK-EU FOR DIVERSE APPLICATIONS Rectangular fire damper for the isolation of duct penetrations between fire compartments,

More information

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES Small rectangular fire damper for the isolation of duct penetrations

More information

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016

Fire damper ETPR Instructions for Installation, Operation and Maintenance 10/2016 Instructions for Installation, Operation and aintenance 10/2016 Installation Fire damper ETPR must be installed according to this installation manual, see pages 2-5. Operation and function testing According

More information

Fire dampers. For diverse applications

Fire dampers. For diverse applications . X X testregistrierung Fire dampers Type with fusible link for 72 C or 95 C CE compliant according to European regulations With TROXNETCOM as an option ATEX certification For diverse applications Rectangular

More information

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU

Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKRS-EU Type FKRS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES Small circular fire damper for the isolation of duct penetrations

More information

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU Type FK-EU FOR DIVERSE APPLICATIONS Rectangular fire damper for the isolation of duct penetrations between fire compartments, for a variety of installation situations, available in many different sizes

More information

Bevent Rasch. FIDm. - Fire /11/2018

Bevent Rasch. FIDm. - Fire /11/2018 Bevent Rasch - Fire - FIDm 27/11/2018 Self-acting back draught damper for combustion gases, with actuator for boosting or control and metering socket for commissioning Sizes from Ø 100 to 20 mm Available

More information

Bevent Rasch RABC-VAV. - Fire /03/2018

Bevent Rasch RABC-VAV. - Fire /03/2018 Bevent Rasch - Fire - RABC-VAV 26/03/2018 Fire damper and VAV-damper combined RABC-VAV Fire resistance class E60 Sizes from 100 mm to 630 mm Prefitted safety actuator 24V Installation in ducts Available

More information

Circular Fire Damper Cartridge

Circular Fire Damper Cartridge Clapets coupe-feu et Volets de désenfumage D.A.S. Organisme Certificateur AFNOR Certification - www.marque-nf.com SC Rf-Technologies nv - Lange Ambachtstraat - 9860 Oosterzele - Belgium - Tel +32 9 362

More information

VL120. Multi blade smoke evacuation damper 120' C-NT-V24-A 01/2016

VL120. Multi blade smoke evacuation damper 120'   C-NT-V24-A 01/2016 VL120 Multi blade smoke evacuation damper 120' en Rf-Technologies nv Lange Ambachtstraat 40 9860 Oosterzele Belgium Tel +32 9 362 31 71 Fax +32 9 362 33 07 info@rft.be www.rft.be C-NT-V24-A 01/2016 2 Table

More information

BKA-EN Fire Damper. Additional operating instructions according to

BKA-EN Fire Damper. Additional operating instructions according to Additional operating instructions according to BKA-EN Fire Damper Contents GENERAL CONDITIONS... 1 DESCRIPTION... 3... 4 EC Certificate of Conformity 0761 CPD 0244 Declaration of Performance 09-19-DoP-BKA-EN-2013-07-01

More information

FIRE PROTECTION FIRE DAMPERS ISONE+

FIRE PROTECTION FIRE DAMPERS ISONE+ FIRE PROTECTION FIRE DAMPERS To achieve this objective, Aldes designs, qualifies, produces and sells, the most extensive, advanced range on the market. RFO, home of Overseas France TV and radio, Guadeloupe

More information

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE

ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE FIRE SAFETY AIR TREATMENT FIRE DAMPERS ESAR SMOKE CONTROL DAMPER» TECHNICAL CATALOGUE 2 ESAR Smoke control damper Technical catalogue Circular smoke control damper ESAR is specially designed to use in

More information

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15 with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017 with coupling device

More information

BSK-RPR Fire Damper. Additional operating instructions according to

BSK-RPR Fire Damper. Additional operating instructions according to Additional operating instructions according to BSK-RPR Fire Damper Contents GENERAL CONDITIONS... 1 DESCRIPTION... 3... 4 EC Certificate of Conformity 0761 CPD 0245 Declaration of Performance 09-22-DoP-BSK-RPR-2013-07-01

More information

SECTION AIR DUCT ACCESSORIES

SECTION AIR DUCT ACCESSORIES SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes back-draft dampers, combination fire-and-smoke dampers, duct access doors, fire dampers, smoke dampers, volume control

More information

Able to respond to smoke alarms for the protection of escape routes and areas with sleeping risk (ADB)

Able to respond to smoke alarms for the protection of escape routes and areas with sleeping risk (ADB) Fire and Smoke Dampers LPCB certificated fire dampers (LPS 1162) ES classified fire dampers with reduced smoke leakage characteristics (BS EN 13501-3) Tested installation methods in differing supporting

More information

Life Safety Dampers Selection and Application Manual

Life Safety Dampers Selection and Application Manual Life Safety Dampers Selection and Application Manual Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers August 2016 1 2 Table of Contents HOW TO USE THIS MANUAL DAMPER

More information

TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S

TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S Brandspjæld BFD-CS Rektangulært brandspjæld FIRE DAMPER Our Fire Damper (BFD-CS) with EN1366-2:1999 EIS120 certification and CE marklet. E Integrity: Integrity is the ability of a component of a fire damper

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES 180-300 INGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNIT 15-25 NOMINAL TON ubmittal Data DECRIPTION The units are one -piece electric cooling/optional electric heating units, prewired and precharged.

More information

FSD-TD Series. Fire and Smoke Dampers B RITAI N. LPCB certificated fire dampers (LPS 1162)

FSD-TD Series. Fire and Smoke Dampers B RITAI N. LPCB certificated fire dampers (LPS 1162) Fire and Smoke Dampers LPCB certificated fire dampers (LPS 1162) ES classified fire dampers with reduced smoke leakage characteristics (BS EN 13501-3) Tested installation methods in differing supporting

More information

Duct Smoke Detector - D4120

Duct Smoke Detector - D4120 Application The primary purpose of duct smoke detection is to prevent injury, panic, and property damage by reducing the spread (recirculation) of smoke. The detector samples air currents passing through

More information

ISIS SAFETY SYSTEM Installation guide

ISIS SAFETY SYSTEM Installation guide ISIS SAFETY SYSTEM Installation guide CAUTION This information is designed to help suitably qualified personnel install and operate Mechan Safety equipment. Before using this product, read this guide thoroughly

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION Vallox 50C FFCT.09.79b.8.009 Code 5 VALLOX Code 5 TCHNICAL PCIFICATION For dwelling-specific ventilation upply and extract air ventilation with heat recovery ilent operation nergy-efficient unit; high-efficiency

More information

INFRARED BUILDING HEATING BOARDS

INFRARED BUILDING HEATING BOARDS INFRARED BUILDING HEATING BOARDS INFRARED BUILDING HEATING BOARDS Electric cables at the back of the Heat Decor board Electric cables at the side of the Heat Decor board Heat Decor boards are infrared

More information

INSTALLATION OF ACCESS FLOOR SYSTEMS IN GENERAL OFFICE AREA AND COMPUTER ROOM

INSTALLATION OF ACCESS FLOOR SYSTEMS IN GENERAL OFFICE AREA AND COMPUTER ROOM INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: Mech Code 601 Effective: 2-07-79 DOCUMENT NO. P/BC 2002-018 Revised: 9-25-03 Previously Issued As: RGA 2-79, MGD101 INSTALLATION OF ACCESS FLOOR

More information

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today.

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today. FIRE & SMOKE DAMPERS Meeting tomorrow's requirements for fire and smoke protection today. LATEST TECHNOLOGY For more than 40 years Ruskin has led the HVAC industry in the manufacture of dampers and louvers.

More information

Technical documentation DTR

Technical documentation DTR Technical documentation DTR ENG TECHNICAL DOCUMENTATION Table of contents. INTRODUCTION. PRECAUTIONS. TRANSPORT. PACKAGE CONTENT. USE AND PRINCIPLE OF OPERATION. DEVICE CONSTRUCTION, DIMENSIONS, TECHNICAL

More information

HRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series

HRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series AKOR BP HR Series AKOR BP HR Energy recovery ventilation systems for single dwelling houses or multi-dwelling blocks, with crossflow heat exchanger. It guarantees continuous air replacement in single dwelling

More information

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES ENG Technical documentation Table of contents. INTRODUCTION. PRECAUTIONS. TRANSPORT.3 PACKAGE CONTENT.4 USE AND PRINCIPLE OF OPERATION.

More information

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES

TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES TECHNICAL DOCUMENTATION DTR AIR WATER HEATERS IN STEEL CASING S SERIES ENG Technical documentation Table of contents 1. INTRODUCTION 1.1 PRECAUTIONS 1.2 TRANSPORT 1.3 PACKAGE CONTENT 1.4 USE AND PRINCIPLE

More information

Ionisation single-tube smoke detector for duct mounting

Ionisation single-tube smoke detector for duct mounting Detectors Ionisation single-tube smoke detector for duct mounting 600 mm venturi tube is included., incl. end resistor (not RAC(M)) 9...33 V DC (via ABV control unit). 24 V AC ±15 % for RAC(M) models.

More information

Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-3S SERIES

Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-3S SERIES Technical documentation DTR AIR WATER HEATERS IN EPP CASING HC-S SERIES PL TECHNICAL DOCUMENTATION Table of contents Heating coil: made of aluminum and copper. The temperature of the heating factor is

More information

Thermostat Catalog 2004

Thermostat Catalog 2004 1 C 1 R 5 6 8 1 R R 6 1 k 5 C 4 1 0 0 p F 9 5 6 7 1 0 1 1 D I D I C D A E C + A E C - V E E V E E D O D O O E M 1 4 1 2 3 C 3 6 + - 5 2 Qo- 3 Q1+ Thermostat Catalog 2004 2 1 2 1 1 3 T1 2-1 - 6W 6 5 4 R

More information

GreenJet Transfer Fans

GreenJet Transfer Fans GreenJet Transfer Fans Model GJX High Performance Axial Transfer Fan April 2018 GreenJet As cars park in an underground parking structure, carbon monoxide (CO) and other noxious fumes are emitted into

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death

More information

Centrifugal air heaters hot water or electrical supply

Centrifugal air heaters hot water or electrical supply The economical solution with centralised production Individual adjustment in each room The most silent electric air heater to protect against frost or to heat large spaces A wide range of accessories Range:

More information

Bevent Rasch. FIDs. - Fire /05/18

Bevent Rasch. FIDs. - Fire /05/18 Bevent Rasch - - FIDs /0/8 Self-acting back draught damper for combustion gases, without commissioning function Sizes Ø 80 to 60 mm For mounting on manifold distribution box BRSL www.bevent-rasch.com Product

More information

Plug-in Base, Long Range Sensor E3B2

Plug-in Base, Long Range Sensor E3B2 Plug-in Base, Long Range Sensor Plug-in Terminal for Easy Maintenance and Installation Universal AC/DC supply voltage Replace sensing head without rewiring Detect shiny objects with polarized retroreflective

More information

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete wet chemical automatic fire suppression system for the exhaust hood, including necessary

More information

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete automatic fire suppression system for the exhaust hood, including necessary accessories.

More information

Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT

Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT 1. General The TBLZ-1-72-a optical smoke detector with built-in control unit is used for measuring

More information

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking Smoke Control Ducts and Dampers For Single Compartment Applications Fulfilling new requirements for EN product standards for CE Marking New Smoke Control Product Range Fläkt Woods Smoke Control Ducts and

More information

Installation Instructions for Honeywell ALL-SPEC Air Sampling Smoke Detection System

Installation Instructions for Honeywell ALL-SPEC Air Sampling Smoke Detection System Installation Instructions for Honeywell ALL-SPEC Air Sampling Smoke Detection System Operating indicator light Alarm indicator light for detector module II Alarm indicator light for detector module I Indicator

More information

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv

More information

LOVAG TEST INSTRUCTION IEC/EN

LOVAG TEST INSTRUCTION IEC/EN LOVAG TEST INSTRUCTION IEC/EN 60947-5-5 CONTROL CIRCUIT DEVICES AND SWITCHING ELEMENTS- ELECTRICAL EMERGENCY STOP DEVICE WITH MECHANICAL LATCHING FUNCTION This test instruction is based on the following

More information

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS

Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS Homepage > Products > Control systems > Demand-based room control with X-AIRCONTROL > Sensors > X-SENS X-SENS SENSORS FOR X-AIRCONTROL ZONE MODULES AND OTHER EQUIPMENT Components for the measurement and

More information

Line Smoke Detector LRMX

Line Smoke Detector LRMX Line Smoke Detector LRMX Motorized detector head User-friendly commissioning via automatic selfadjustment Disturbance-protected operation via automatic electromechanical tracking of the detector head during

More information

Fire/Smoke damper EKO-SRBG2

Fire/Smoke damper EKO-SRBG2 Fire/Smoke damper EKO-SRBG2 Instructions for installation, operation and maintenance 2014-04 Instructions for installation, operation and maintenance EKO-SRBG2 Contents Handling the product...3 General

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D2 MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D2 GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

VACUUM CONTACTOR TYPE SVC-T 32. 7,2 kv A MANUAL FOR MOUNTING, OPERATION AND MAINTENANCE

VACUUM CONTACTOR TYPE SVC-T 32. 7,2 kv A MANUAL FOR MOUNTING, OPERATION AND MAINTENANCE VACUUM CONTACTOR TYPE SVC-T 32 7,2 kv - 400 A MANUAL FOR MOUNTING, OPERATION AND MAINTENANCE CONTENTS PAGE 1. Introduction...2 1.1 Acceptance inspection on delivery...2 2. General...2 3. Standards and

More information

SmartShelter Room. Technical Description. Version 1.1 Jul. 2017

SmartShelter Room. Technical Description. Version 1.1 Jul. 2017 SmartShelter Room Technical Description Version 1.1 Jul. 2017 Introduction to SmartShelter Solution... 3 Main technical advantages... 3 Standards... 3 Applications... 4 SmartShelter Room... 5 Self-standing

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 619PB HIGH WALL DUCTLE YTE IZE 09 TO 36 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIIT, ENERGY AVING AND COFORT. The 619PB series ductless systems are a matched combination

More information

SECTION OVERHEAD COILING FIRE DOORS

SECTION OVERHEAD COILING FIRE DOORS SECTION 08331 OVERHEAD COILING FIRE DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on round Windows logo in top left corner,

More information

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS Compact heat recovery unit with high efficiency counter-flow heat exchanger in 5 sizes from 580 m3/h to 3.650 m3/h. The casing is made from aluminium profile

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS 40MB*D Ducted tyle Ductless ystem izes 09 to 48 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIMIT, ENERGY AVING AND COMFORT. The 40MB*D series ducted style ductless

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION VALLOX-product code: HVAC code: 358500 L 35850 R 79076 L 79077 R SOUND ATTENUATOR (OPTIONAL) IVALLOX 252 WATER OPERATED POST- HEATING UNIT (OPTIONAL) ELECTRICAL POST-HEATING UNIT (OPTIONAL) ELECTRICAL

More information

IRBB Inert gas damper

IRBB Inert gas damper AGAB PRODUT DATASEET Rectangular damper to prevent the spread of fire and fire gas for placement in structural elements with a fire resistance rating of EI 120 or EI 60. Additional fire insulation is required

More information

1.1 VTS: number 1 in the world pillars of success

1.1 VTS: number 1 in the world pillars of success Heating Unit 01 VTS GROUP 1.1 VTS: number 1 in the world 1.2 3 pillars of success 02 2.1 water hearers Modernity Innovativeness Energy efficiency 2.2 Assembly 2.3 VR-D destratifier 2.4 Automation 03 TECHNICAL

More information

Technical data lumina PM

Technical data lumina PM 1. Product description Technical data The presence detector is suitable for detecting the movement of humans and animals through their radiant heat. The sensitive 4-element-PIR sensor technology for presence

More information

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MAQ High Wall Ductless System Sizes 09 to 36

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 40MAQ High Wall Ductless System Sizes 09 to 36 40AQ High Wall Ductless ystem izes 09 to 36 Product Data INDUTRY LEADING FEATURE / BENEFIT A PERFECT BALANCE BETWEEN BUDGET LIIT, ENERGY AVING AND COFORT. The 40AQ series ductless split systems are a matched

More information

Technical documentation DTR. Farmer HCF in EPP casing

Technical documentation DTR. Farmer HCF in EPP casing Technical documentation DTR Farmer HCF in EPP casing ENG TECHNICAL DOCUMENTATION Table of contents. INTRODUCTION. PRECAUTIONS. TRANSPORT. PACKAGE CONTENT.4 USE AND PRINCIPLE OF OPERATION. DEVICE CONSTRUCTION,

More information

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE / 3 GM20 Digital Ground Continuity Relay For AC Systems Technical Bulletin NAE03230 / 0.20 GM20 Ground continuity monitor For AC systems Description The GM20 monitors the loop resistance of ground conductors

More information

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015 Peter McDonnell, PE, LEED AP BD+C McClure Engineering UL DAMPER TEST STANDARDS UL 555 - FIRE DAMPERS UL555S SMOKE DAMPERS UL555C CEILING

More information

Fire and Smoke Control Systems

Fire and Smoke Control Systems Control Systems Electrical Mechanical Standard Panel Modular design for control and monitoring Premier Panel Customised design for control and monitoring Fully Addressable Fully programmable data wired

More information

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product

More information

Chilled Water DOAS Fan Powered Terminal Units

Chilled Water DOAS Fan Powered Terminal Units Chilled Water DOAS Fan Powered Terminal Units CHILLED WATER DOAS FAN POWERED TERMINAL UNITS DOAS TERMINAL UNITS FEATURES AND BENEFITS MINIMUM VENTILATION CONTROL The DOAS unit provides the Designer, Owner

More information

TUNNEL FANS STANDARD AND HOT SMOKE

TUNNEL FANS STANDARD AND HOT SMOKE TUNNEL FANS STANDARD AND HOT SMOKE NovAx tunnel fans PRODUCT FACTS Product Novenco tunnel fans are produced with either round or rectangular outer dimensions. Both types are made in unidirectional (AUC

More information

COOLflow 4E PRODUCT RANGE

COOLflow 4E PRODUCT RANGE COOLflow 4E PRODUCT RANGE FREE AIR COOLING FROM THE FREE AIR SPECIALISTS GUARANTEED TO SIGNIFICANTLY REDUCE CARBON EMISSIONS & DELIVER ENERGY SPEND SAVINGS OF UP TO 95% The COOLflow 4E range has been developed

More information

INSTALLATION INSTRUCTION BOOKLET FOR SMOKE DAMPERS

INSTALLATION INSTRUCTION BOOKLET FOR SMOKE DAMPERS INSTALLATION INSTRUCTION BOOKLET FOR SMOKE DAMPERS Instructions included in this booklet: IOM # Description Page(s) 46133 SMD-XXX, SESMD-XXX, SSSMD-XXX, SMD-XXX Series - 46313 Smoke Detector (DH100ACDCLP)

More information

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V IR1575_D00116_00_D_XXEN/05.2015 Insulation monitoring device for unearthed AC/3(N)AC systems up to 480

More information

Lo-Carbon Quadra SELV

Lo-Carbon Quadra SELV Lo-Carbon Quadra SELV Installation and Wiring Instructions Stock Ref. N Quadra SVTP 442865 Quadra SVHTP 442866 Quadra SVTM 442867 Safety Extra Low Voltage IPX7 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH

More information

MANUAL RESET ALARM RELEASE

MANUAL RESET ALARM RELEASE Fire Door Release MODEL AR-D MANUAL RESET ALARM RELEASE INSTRUCTION MANUAL AR-D GENERAL INFORMATION 1. Review all installation instructions, procedures, cautions and warnings contained within this manual

More information

SECTION (15820) - AIR DUCT ACCESSORIES

SECTION (15820) - AIR DUCT ACCESSORIES PART 1 GENERAL 1.01 SUMMARY A. Section includes: SECTION 23 33 00 (15820) - AIR DUCT ACCESSORIES 1. Manual-Volume Dampers 2. Fire Dampers 3. Turning Vanes 4. Duct-Mounted Access Doors 5. Flexible Connectors

More information

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone

More information

Novenco jet fans. AUO / ARO / AUT / ART / CGF January 2010

Novenco jet fans. AUO / ARO / AUT / ART / CGF January 2010 Novenco jet fans AUO / ARO / AUT / ART / CGF January 2010 Product facts Product Novenco jet fans are produced in unidirectional (AU_ and CGF) and reversible (AR_) versions. AUT/ART circular Basic jet fans

More information

Technical documentation: S1 S2 S3 S4

Technical documentation: S1 S2 S3 S4 Technical documentation: S1 S2 S3 S4 1 Table of contents: 2 1. Introduction 3 1.1 Precautions 3 1.2 Transport 3 1.3 Package content 4 1.4 Use and principle of operation 4 2. Schematic diagram 4 2.1 Construction

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 42" WOODBURNING FIREBOX Model C42EC2 Circulating (Louvered) INSTALLATION INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance,

More information

Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure DN 32 DN 80

Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure DN 32 DN 80 Mounting and operating instructions KEMPER KTS temperature-controlled 3-directional reversing valve Figure 955 01 DN 32 DN 80 Figure 1: DN 32 - DN 50 Figure 2: DN 65 - DN 80 Table of Contents 1 General

More information

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product

More information

Technical documentation

Technical documentation Technical documentation AIR WATER HEATERS IN STEEL CASING S SERIES MODELS: REVENTON GROUP S1-3S REVENTON GROUP S2-3S REVENTON GROUP S3-3S REVENTON GROUP S4-3S ENG TECHNICAL DOCUMENTATION Table of contents

More information

Louvers & Dampers April Product Guide Specification SECTION COMBINATION FIRE SMOKE DAMPERS

Louvers & Dampers April Product Guide Specification SECTION COMBINATION FIRE SMOKE DAMPERS Louvers & Dampers April 2008 P.O. Box 606 7435 Industrial Road Florence, Kentucky, 41042 Phone: (859) 647-2299 Fax: (859) 647-7810 Web Site: www.louvers-dampers.com Product Guide Specification SECTION

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION The 2SD04700124 Smoke Detector Kit contains the parts and hardware to mount the smoke detector in the following applications: A. Supply Air Stream (Blower Compartment) B. Return Air Stream

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ELIMINATOR 36 Wood Burning Fireplace Models: 36E Non-Circulating (Smooth Face) I36E Non-Circulating (Smooth Face) Fully Insulated INSTALLATION INSTRUCTIONS SAVE THIS BOOK This book is valuable. In addition

More information

Küba SG commercial

Küba SG commercial GEA Küba 42 Küba Blue Line : Specific advantages High performance air cooler for commercial applications with a large scope and complete capacity spectrum. Draw-through fans guide the air flow evenly through

More information

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13.

AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR. Air Conditioner for Telecommunication Base Station. Cooling Capacity: 3.4~13. AIRSYS-P-SC-MOBILECOOL-INDOOR-E1507V01.2 MOBILECOOL-INDOOR Air Conditioner for Telecommunication Base Station Cooling Capacity: 3.4~13.4kW MOBILECOOL-INDOOR unit is one of the products of AIRSYS BTS air

More information

5, SE GÅNGHESTER,

5, SE GÅNGHESTER, KSUB Control and monitoring unit Valid from week of manufacture 48/2005 Description The KSUB is a control and monitoring unit designed to control various types of fire/smoke dampers and fans in a flexible

More information

Domestic & Commercial Fans

Domestic & Commercial Fans Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO

More information

CEILING DAMPER BASICS

CEILING DAMPER BASICS EILING DAMPER BASIS eiling Damper Basics Definition of a eiling Damper (quoted from NFPA Standard 90A): A device installed to limit radiant heat transfer through an air outlet or air inlet opening in the

More information

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits VentZone Zoned IAQ Kits with Heat Recovery combine a Standard Residential Heat Recovery Ventilator (HRV) with residential

More information

Schedule of Accreditation

Schedule of Accreditation Schedule of Accreditation Organisation Name Trading As INAB Reg No 6023 Contact Name Address BRE Global Assurance (Ireland) Ltd David Gall Contact Phone No +353 1 882 4344 Email Website Accreditation Standard

More information

Thermostat Catalog 2004

Thermostat Catalog 2004 1 C 1 R 5 8 1 R R 1 k 5 C 4 1 0 0 p F 9 5 7 1 0 1 1 D I D I C D A E C + A E C - V E E V E E D O D O O E M 1 4 1 2 3 C 3 + - 5 2 Qo- 3 Q1+ Thermostat Catalog 2004 2 1 2 1 1 3 T1 2-1 - W 5 4 R 3 1 0 0 R

More information

Replacement of pneumatic actuators on Ruskin negator spring dampers with Belimo FSxx Series

Replacement of pneumatic actuators on Ruskin negator spring dampers with Belimo FSxx Series WARNING! Before replacing actuator, damper must be inspected and determined to be fully functional. See NFPA checklists below. Contents Replacement of pneumatic actuators on Ruskin negator spring dampers

More information

Technology for life. Unit heater LH

Technology for life. Unit heater LH Technology for life. Unit heater 1 2 Contents Contents... Page Basic unit: casing, fan, motors... 4 Basic unit: heat exchanger... 5 Performance tables 25...6-7 Performance tables 40...8-9 Performance tables

More information

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Convertible radiator valve for one-pipe systems, centre distance 35 mm Convertible radiator valve for one-pipe systems, centre distance 35 mm 56 series ACCREDITED ISO 900 FM 65 033/6 GB Function 56 series convertible radiator valves are used on one-pipe radiator systems.

More information

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits RESIDENTIAL SYSTEM SOLUTIONS VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits VentZone Zoned IAQ Kits with Energy Recovery combine a Standard Residential Energy Recovery Ventilator (ERV) with

More information

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon alarm devices For fire detector and extinguishing systems Loud alarm signal clearly recognizable as a danger signal even in noisy environments

More information

Air distribution systems. Rectangular displacement outlet VA-RN... with adjustment device VA-RV...

Air distribution systems. Rectangular displacement outlet VA-RN... with adjustment device VA-RV... Air distribution systems Rectangular displacement outlet VA-RN... with adjustment device VA-RV... DS 4009 E 06.2012 Design and function Preliminary remarks Displacement air outlets are used in rooms with

More information