Section - III SYSTEMS DESCRIPTION

Size: px
Start display at page:

Download "Section - III SYSTEMS DESCRIPTION"

Transcription

1 Section - III SYSTEMS DESCRIPTION Pro Line 21 Table of Contents Page GENERAL SYSTEM LOGIC CONTROLS and ANNUNCIATIONS OPERATION STALL WARNING SYSTEM STALL IDENTIFICATION SYSTEM Figure 1 - Stall Valve Annunciators Figure 2 - Variation of Stall Identification Angle With Rate of Increase of Vane Angle THIRD STALL IDENTIFICATION CHANNEL Figure 3 - Stall Warning and Identification Figure 4 - Stall System Pitot Static Block Diagram SYSTEM FAULTS and ANNUNCIATIONS Figure 5 - System Fault Annunciators FLAP ASYMMETRY WEIGHT-ON-WHEELS ASYMMETRY SSU SELF TEST SYSTEM ANNUNCIATORS Table 1: Summary of Annunciators SYSTEM POWER SUPPLIES Table 2: Power Supplies STALL WARNING and IDENTIFICATION LOGIC Figure 6 - Stall System Flow Logic Page 7-1

2 Intentionally left blank Page 7-2

3 GENERAL Hawker 800XP Pro Line 21 NOTE: This section applies to 800XP Pro Line 21 airplanes prior to Serial No For airplanes Serial Nos and subsequent, refer to Section VIII SUPPLEMENTS for Supplement P/N A stall warning and identification system is provided to emphasize the airplane s natural cues available at the point of stall. The system functions are Stick shaker (warning) Stick pusher (identification) The system consists of Two sensing channels, each utilizing an airflow angle sensor vane. Two Signal Summing Units (SSUs). Two stick shaker motors. A hydraulic operated actuator with two electro-hydraulic valves. A third sensing channel, which utilizes pitot pressure from the right pitot head, static pressure from the forward static plates and stall vent pressure from the left and right stall vents. A stall identification sensor. Annunciators and test switches. SYSTEM LOGIC 1. It is impossible for a stick push to occur before a stall warning (stick shake). 2. No single active fault of an SSU or relay can cause the operation of a stall valve or the associated red STALL VALVE annunciator. 3. The autopilot is disengaged when a stall warning signal is initiated. This prevents the autopilot from attempting to counteract the resulting stick shake operation or a subsequent stick push. CONTROLS and ANNUNCIATIONS System faults are indicated on two groups of amber annunciators, one per pilot. Three STALL switches are located in the TEST section of the overhead roof panel. Anti-icing heating of the airflow sensor vanes is controlled from the PITOT/VANE HEAT switches. Indication of failure of the vane heaters is provided by the two amber L and R VANE HTR FAIL annunciators also located on the overhead roof panel and by the ICE PROT repeat annunciator on the MWS panel. There are no control switches, the stall warning part of the system becomes armed on takeoff (no weight-on-wheels), while the stall identification part of the system becomes armed 6 seconds after takeoff. Page 7-3

4 OPERATION STALL WARNING SYSTEM The stall warning system uses an electrically driven stick shaker on each control column to provide a physical warning of an approaching stall to the pilots. Angle of attack is derived from two electrically heated airflow angle sensor vanes mounted one on each side of the forward fuselage. Electrical signals proportional to vane angle are sensed in the associated Signal Sensor Unit which also receives inputs relating to flap angle. From the flap angle signal, the SSU calculates the point of stall warning. When the vane angle corresponds to that point the SSU provides an output to operate the stick shaker motor on each control column. The stall warning system is inhibited while the airplane is on the ground with weight-on-wheels to prevent wind gusts triggering false stick shaker operations. At takeoff, the system is armed and begins monitoring the pitch attitude of the airplane. STALL IDENTIFICATION SYSTEM The stall identification system uses a hydraulic stick pusher to force the control column forward (pitch down) at the calculated point of stall. The stick pusher is powered by main hydraulic system pressure (backed by the main accumulator), the rate of operation being controlled by a fluid restrictor. Control of the hydraulic pressure to the stick pusher is via two independent stall valves (A and B), connected in series and mounted integral with the stick pusher. Both stall valves must be open to activate the unit. STALL VLV A OPEN STALL VLV B OPEN M6950_0 HA00C AA.AI Figure 1 Stall Valve Annunciators The output from one SSU energizes one stall valve, and an associated red STALL VLV (A or B) OPEN annunciator is illuminated to indicate that the valve is being signalled to open (reference Figure 1). The SSU uses the vane sensor and flap angle inputs to calculate the point of stall. The rate of increase of vane angle may also modify the calculation, i.e. the point of stall being advanced when the rate of increase is high dynamic stall (reference Figure 2). When the vane angle agrees with the calculated point of stall, the SSU produces an output (stall identification) to energize the associated stall valve and annunciator. When a SSU produces a stall warning output, which is then followed by an identification signal, the warning signal latches the stall identification relay for the same channel (reference Figure 3). A warning signal from either channel will disconnect the autopilot and operate the stick shaker. The latch is removed when the warning output ceases. This makes sure the stick push is maintained until the airplane has reached a nose-down attitude well below the stall point. Page 7-4

5 28 VANE ANGLE to HFD (Degrees) FLAP 0 IDENT FLAP > 0 IDENT FLAP 0 WARN FLAP 15/25 WARN FLAP 45 WARN VANE RATE - DEGREES/SECOND NOTE: HFD is the Horizontal Fuselage Datum. Figure 2 Variation of Stall Identification Angle with Rate of Increase of Vane Angle Page 7-5

6 THIRD STALL IDENTIFICATION CHANNEL A third channel for stall identification is provided by a pitot/static system which uses pitot pressure (P2) from the right pitot head, static pressure (S6) from the forward static vents and a vent pressure (V) from left and right stall vents. The stall vents are located on the under-side of the left and right wings (reference Figure 4). These pressures are sensed by a capsule operated stall detector, which is set to produce an output at a point between the settings for the stall warning and identification signals from the SSUs. The output from the third channel sensor energizes a relay which connects the stall identification output from one channel s SSU to the stall valve of the other channel. Thus, with the third channel output activated, both stall valves A and B will open following a stall identification output from only one SSU, thereby ensuring system integrity should a SSU fail. VANE ANGLE SENSOR I N P U T SSU WARN IDENT 3rd CHANNEL STALL VENT PITOT PRESSURE HYDRAULIC PRESSURE STALL VALVE A FLAP ANGLE LEFT and RIGHT STICK - SHAKER MOTORS 3rd CHANNEL VANE ANGLE SENSOR I N P U T IDENT WARN SSU 3rd CHANNEL STALL VENT STATIC PRESSURE STALL VALVE B STICK PUSHER Page 7-6 Figure 3 Stall Warning and Identification

7 Left Forward Static Vent Plate S6 Right Forward Static Vent Plate 6 6 Stall Ident (Autopilot Disconnected) V Stall Detector P S Pitot Isolation Valve Right Pitot Head P2 Stall Ident 3rd Channel V Stall Detector S P P2 Left Stall Vent V1 S6 Right Stall Vent V2 LEGEND = Pitot Pressure = Pitot Drain = Static Pressure = Static Drain = Stall Vent Pressure = Stall Vent Drain Figure 4 Stall System Pitot Static Block Diagram Page 7-7

8 SYSTEM FAULTS and ANNUNCIATIONS The duplication of the stall warning system makes sure a single passive fault cannot prevent a stick shake occurring. Should an active fault develop, the faulty system can be isolated via the appropriate circuit breaker. The remaining good system will still operate both stick shaker motors. The stall identification system is designed that a single active fault cannot give an inadvertent stick push, while making sure a single passive fault would not prevent a push operation occurring, when required. All annunciator warnings in the stall warning and identification system will also cause a repeater STALL IDENT annunciator on the MWS panel to illuminate (reference Figure 5). The power to energize a stall valve is routed via the identification relay of one channel and the warning relay of the other channel. A monitoring circuit will cause an IDENT 1 or IDENT 2 annunciator (depending on the channel at fault) to be illuminated after a 4 second time delay, if an identification signal from one SSU has been triggered without a warning signal from the other SSU. The IDENT 1 or IDENT 2 annunciators are part of the IDENT/INHIB switches provided for both pilots. When an IDENT annunciator illuminates, either pilot can push the associated switch to inhibit the faulty channel. The INHIB annunciator part of the switch will then illuminate. The third channel sensor, together with the remaining SSU would provide a stick push operation when required. MWS Panel M6949_0 HA00C AA.AI Figure 5 System Fault Annunciators The pilots may attempt to reset the failed channel by operating an INHIBIT RESET switch located on the stall diagnostic panel (forward side of the Pilot s bulkhead). Should the channel fail again after reset, it should be inhibited and left in that condition for the remainder of the flight. Page 7-8

9 FLAP ASYMMETRY If asymmetry between the left and right flap positions exists for more than 2 seconds, then the FLAP annunciator (Pilot s group only) will illuminate. WEIGHT-ON-WHEELS ASYMMETRY If asymmetry between the positions of the left and right weight-on-wheels relays exists for more than 4 seconds, then a SQUAT annunciator (Copilot s group only) will illuminate. SSU SELF TEST A built-in test within the SSU detects the following faults: Loss of 26 VDC supply Loss of internal power or short circuit Loss of airflow angle sensor excitation Loss of flap position input Airflow angle sensor transformer winding open or short circuit If any of the above occur, an external relay causes a SSU annunciator to illuminate. If the weight-onwheels switch is in the flight condition, a magnetic indicator associated with the faulty SSU will display white. The magnetic indicators are located on the stall identification diagnostic panel. Page 7-9

10 SYSTEM ANNUNCIATORS Table 1: Summary of Annunciators Function Annunciator MWS Panel Airflow angle sensor left or right vane heating malfunction VANE HTR FAIL L (R) # VANE HTR FAIL ICE PROT Flap position asymmetry FLAP FLAP Stall identification channel 1 (2) (3) fault IDENT 1 (2) (3) IDENT # Signal Summing Unit fault SSU SSU STALL IDENT Weight-On-Wheels asymmetry SQUAT SQUAT Stall valve A (B) operating STALL VLV A (B) OPEN STALL VLV # OPEN SYSTEM POWER SUPPLIES Table 2: Power Supplies Panel Location Row/Column B/1 B/4 B/6 B/2 B/5 B/7 B/3 Circuit Breaker Circuit or Equipment Busbar STALL IDENT 1 26 VAC input to SSU 1 XS 1 STALL VLV A STALL WARN MOTOR 1 (LH) 28 VDC to stall valve 1 and annunciators PS1(a) 28 VDC to stick shaker motor 1 PS1(a) STALL IDENT 2 26 VAC input to SSU 2 XS 2 STALL VLV B STALL WARN MOTOR 2 (RH) 28 VDC to stall valve 2 and annunciators PS2(a) 28 VDC to stick shaker motor 2 PS2(a) STALL IDENT 3 28 VDC to SSU 3 PE Page 7-10

11 STALL WARNING and IDENTIFICATION LOGIC (Figure 6) START ANGLE OF ATTACK CONTINUES TO INCREASE ANGLE OF ATTACK MONITORED BY AIRFLOW ANGLE SENSOR STALL WARNING TRIGGER POINT & STALL IDENTIFICATION TRIGGER POINT MODIFIED BY FLAP ANGLE ANGLE OF ATTACK INCREASING? NO STALL IDENTIFICATION TRIGGER POINT MODIFIED BY RATE OF INCREASE OF ANGLE OF ATTACK. SSU 1 AND/OR SSU 2 INITIATE IDENTIFICATION SIGNAL WHEN THE AIRPLANE IS AT POINT OF STALL Channel 3 APPROACHING STALL SENSED AT UNDER-WING PRESSURE VENTS 3rd CHANNEL SENSOR IS ACTIVATED YES BOTH SSU IDENT SIGNALS OPERATED ONLY ONE SSU IDENT SIGNAL OPERATED NEAR TO STALL? NO Channel 1 SSU 1 CALCULATES APPROACHING STALL AND INITIATES A WARNING SIGNAL Channel 2 SSU 2 CALCULATES APPROACHING STALL AND INITIATES A WARNING SIGNAL 3rd CHANNEL RELAY ENERGIZES TO CONNECT ACTIVE SSU OUTPUT TO BOTH STALL VALVES YES WARNING SIGNAL FROM EITHER CHANNEL DISCONNECTS AUTOPILOT AND OPERATES THE STICK SHAKER OR ANGLE OF ATTACK INCREASING? YES NO PREVENTIVE ACTION TAKEN BY PILOT STALL VALVE A OPEN AND STALL VALVE B OPEN STICK PUSHER ACTIVATED Figure 6 Stall System Flow Logic Page 7-11

12 Intentionally left blank Page 7-12

SD3-60 AIRCRAFT MAINTENANCE MANUAL SYSTEM - DESCRIPTION & OPERATION (PRE MOD A8005)

SD3-60 AIRCRAFT MAINTENANCE MANUAL SYSTEM - DESCRIPTION & OPERATION (PRE MOD A8005) SD3-60 AIRCRAFT MAINTENANCE MANUAL z AMM 22.0.0.0STALL WARNING SYSTEM - DESCRIPTION & OPERATION (PRE MOD A8005) 1. Description A. General Physical and aural warning of an incipient stall condition is respectively

More information

Section - III SYSTEMS DESCRIPTION

Section - III SYSTEMS DESCRIPTION Section - III SYSTEMS DESCRIPTION Pro Line 21 Table of Contents Page GENERAL...1-3 ANNUNCIATOR TYPES...1-3 ARRANGEMENT...1-3 REPEATER ANNUNCIATORS...1-3 Figure 1 - Master Warning Annunciations and Controls...1-4

More information

Kelly Aerospace Willoughby, OH NC , Rev. A FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT FOR LC40-550FG AIRFRAME DE-ICING SYSTEM

Kelly Aerospace Willoughby, OH NC , Rev. A FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT FOR LC40-550FG AIRFRAME DE-ICING SYSTEM Aircraft SN: Aircraft Registration Number: This supplement must be attached to the FAA approved flight manual when the Kelly Aerospace airframe de-icing system is installed in accordance with STC SA02660CH.

More information

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS The Warning and Caution systems are discussed here in conjunction with the Warning and Test Systems, primarily to cover the procedures for testing

More information

Section - III SYSTEMS DESCRIPTION

Section - III SYSTEMS DESCRIPTION Section - III SYSTEMS DESCRIPTION Table of Contents Hawker 800XP Pro Line Page GENERAL...4-3 Figure - Engine Fire Detection and Warning System Component Locations...4-3 CONTROLS and INDICATIONS...4-4 ENGINE

More information

Fokker 50 - Integrated Alerting Unit

Fokker 50 - Integrated Alerting Unit GENERAL Failure conditions are processed by an Integrated Alerting Unit (IAU) for visual and aural presentation to the pilots. Pre-stall warning and ground proximity warning are not integrated. The IAU

More information

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS

WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS MODEL 680 WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS The Warning and Caution systems are discussed here in conjunction with the Warning and Test Systems, primarily to cover the procedures

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL MODEL SR INDICATING/RECORDING SYSTEMS 1. DESCRIPTION This section describes the Indicating/Recording Systems which consists of an Annunciator Panel and related sensors and switches. The annunciator assembly

More information

DASSAULT AVIATION Proprietary Data

DASSAULT AVIATION Proprietary Data F2000EX EASY 02-38-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-38 02-38-00 TABLE OF CONTENTS 02-38-05 GENERAL Introduction Sources Equipment location 02-38-10 DESCRIPTION General 02-38-15 CONTROL AND INDICATION

More information

DASSAULT AVIATION Proprietary Data

DASSAULT AVIATION Proprietary Data F900EX EASY 02-38-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-38 02-38-00 TABLE OF CONTENTS 02-38-05 GENERAL Introduction Sources Equipment location 02-38-10 DESCRIPTION General 02-38-15 CONTROL AND INDICATION

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL INDICATING/RECORDING SYSTEMS 1. DESCRIPTION This section describes the Indicating/Recording Systems which consists of an Annunciator Panel and related sensors and switches. A. Annunciator Panel - Serials

More information

A D U ANNUNCIATOR DIM / TEST UNIT INSTALLATION MANUAL DESCRIPTION AND THEORY OF OPERATION

A D U ANNUNCIATOR DIM / TEST UNIT INSTALLATION MANUAL DESCRIPTION AND THEORY OF OPERATION AVIONICS ENGINEERING SERVICES A D U ANNUNCIATOR DIM / TEST UNIT INSTALLATION MANUAL DESCRIPTION AND THEORY OF OPERATION Document No. 92-0003-06 REV C May 31, 2000 INSTALLATION MANUAL DESCRIPTION AND THEORY

More information

CO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr.

CO Guardian LLC Document No E. AIRPORT DRIVE Date: TUCSON, AZ CO Guardian LLC 1951 E. Airport Dr. 1951 E. AIRPORT DRIVE Date: 8-20-2004 CO Guardian LLC 1951 E. Airport Dr. Tucson, AZ 85706 OWNERS MANUAL CARBON MONOXIDE DETECTOR MODEL 452-201 REMOTE UNIT MODEL 452-201 OWNERS MANUAL Page 1 of 22 INTENTIONALLY

More information

CHAPTER - 30 HIGHLIGHTS (Summary of Changes) Revision No. TR30-6 Dec 21/18 TO: HOLDERS OF THE AIRCRAFT MAINTENANCE MANUAL ( )

CHAPTER - 30 HIGHLIGHTS (Summary of Changes) Revision No. TR30-6 Dec 21/18 TO: HOLDERS OF THE AIRCRAFT MAINTENANCE MANUAL ( ) CHAPTER - 30 HIGHLIGHTS (Summary of Changes) Revision No. TR30-6 TO: HOLDERS OF THE AIRCRAFT MAINTENANCE MANUAL (06-117751) Pages that have been added or revised are summarized below. Remove and insert

More information

REFERENCE ONLY FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT

REFERENCE ONLY FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT SUPPLEMENTAL TYPE CERTIFICATE NUMBER SA11103SC INSTALLATION OF SAFETY SYSTEMS FOR BEECHCRAFT B200GT AND B200CGT AIRPLANES IN THE KING AIR 250 CONFIGURATION (PRO LINE 21 AND PRO LINE FUSION AVIONICS) FAA

More information

Pressurization System

Pressurization System Pressurization System FILTER N.O. PRESET SOLENOID MOISTURE DRAIN ALTITUDE LIMIT CONTROLLER ALTITUDE LIMIT CONTROLLER MOISTURE DRAIN OUTFLOW SAFETY STATIC AIR Environmental Systems RATE ALTITUDE VACUUM

More information

71717 SERIES FLAMMABLE MATERIAL LOCATIONS

71717 SERIES FLAMMABLE MATERIAL LOCATIONS 71 FLAMMABLE MATERIAL LOCATIONS (tab) CAUTION: Rescue crews wearing full PPE to include SCBA s must use caution when moving across sections of aircraft that have been exposed to fatigue or fire as the

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL COOLING 1. DESCRIPTION On aircraft serials 183 and subsequent, an optional air condition system is available. This section contains the maintenance practices pertinent to this system. Cabin ventilation

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL All HEATING 1. DESCRIPTION The cabin air heating system is covered in this section. Serials 1005 thru 138: Heated air is available at floor level for all occupants. Positive pressure inside the engine

More information

Dornier 328Jet - Lights

Dornier 328Jet - Lights LIGHT and ENGINE START Control Panel (Sheet 1 of 5) Page 1 Light and ENGINE START Control Panel (Sheet 2 of 5) Page 2 LIGHT and ENGINE START Control Panel (Sheet 3 of 5) Page 3 LIGHT and ENGINE START Control

More information

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL OWNERS MANUAL CARBON MONOXIDE DETECTOR MODELS Panel mount and Remote Detectors (R) (353 and 353R) 353 FAMILY MODEL OWNERS/INSTALLATION MANUAL Page 1 of 22 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION

More information

Canadair Regional Jet 100/200 - Water & Waste

Canadair Regional Jet 100/200 - Water & Waste INTRODUCTION The water and waste systems include potable water, lavatory waste equipment and system controls. Two potable water systems store and supply potable water to the galley and lavatory. The forward

More information

Engine Fire Protection System

Engine Fire Protection System Engine Fire Protection System 1 1 LEFT FEED BUS LEFT CB PANEL CROSSOVER RIGHT FEED LEFT CB PANEL Fire Protection ARM UNLOCK DEPLOY S T EMER O W S NORM W BOTTLE 1 ARMED PUSH LH ENG FIRE PUSH RH ENG FIRE

More information

Liberty XL2 Emergency Procedures Checklist

Liberty XL2 Emergency Procedures Checklist EMERGENCY PROCEDURES XL2 GENERAL This section provides the recommended procedures for coping with various emergency or critical situations. All of the emergency procedures required by the FAA, as well

More information

C I R R U S HEATING DESCRIPTION A. Cabin Air Heating System - Serials thru

C I R R U S HEATING DESCRIPTION A. Cabin Air Heating System - Serials thru HEATING 1. DESCRIPTION This section covers those systems and components used to supply heated air. Includes items such as heater panels and other units, indicating systems related to heater operation,

More information

Instrument and Control Panels

Instrument and Control Panels GENERAL Instrument and Control Panels 31-10: INSTRUMENT AND CONTROL PANELS 1. General A. Instrument Panel A Garmin Primary Flight Display (PFD) is mounted in the instrument panel. The Engine Start Controls

More information

FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT

FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT SUPPLEMENTAL TYPE CERTIFICATE NUMBER SA11103SC INSTALLATION OF SAFETY SYSTEMS FOR BEECHCRAFT B200GT AND B200CGT AIRPLANES IN THE KING AIR 250 CONFIGURATION (PRO LINE 21 AND PRO LINE FUSION AVIONICS) FAA

More information

OWNERS MANUAL MODEL 451 (-101 & -201)

OWNERS MANUAL MODEL 451 (-101 & -201) OWNERS MANUAL MODEL 451 (-101 & -201) Guardian Avionics CO Guardian, LLC. 1951 E Airport Drive Tucson, AZ 85756 Phone: 520-889-1177 8:00 am - 5:00 pm MST support@guardianavionics.com 2 Table of Contents

More information

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 16 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

Fokker 50 - Fire Protection

Fokker 50 - Fire Protection ENGINE General The engines are each equipped with a fire detection and a fire extinguishing system. The systems are controlled from the ENGINE FIRE panel, which is located at the overhead panel. Fire and

More information

DASSAULT AVIATION Proprietary Data

DASSAULT AVIATION Proprietary Data FALCON 7X 02-33-05 CODDE 1 PAGE 1 / 4 GENERAL ACRONYMS LIST BATT CB EPS LED LH MAU OP PPDB RH SSPC Battery Circuit Breaker Emergency Power Supply Light Emitting Diode Left Hand Modular Avionic Unit Overhead

More information

DASSAULT AVIATION Proprietary Data

DASSAULT AVIATION Proprietary Data F2000EX EASY 02-26-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-26 02-26-00 TABLE OF CONTENTS 02-26-05 GENERAL Introduction Sources 02-26-10 DESCRIPTION Introduction Fire detection Fire extinguishing Portable

More information

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.

OWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ. OWNERS MANUAL CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) (353-101 and 353-201) 353 FAMILY MODEL OWNERS/INSTALLATION MANUAL Page 1 of 22 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION

More information

EMERGENCY PROCEDURES XL2

EMERGENCY PROCEDURES XL2 ENGINE FAILURE DURING FLIGHT GENERAL EMERGENCY PROCEDURES XL2 This section provides the recommended procedures for coping with various emergency or critical situations. All of the emergency procedures

More information

MANUAL SPEED SENSOR MSPEED

MANUAL SPEED SENSOR MSPEED MANUAL SPEED SENSOR MSPEED 1. INTRODUCTION... 2 2. DESCRIPTION... 2 3. CONNECTING MSPEED... 2 3.1 CONNECTING MSPEED TO THE JETI BOX... 3 3.1 CONNECTING MSPEED TO THE DUPLEX RECEIVER... 3 3.2 CONNECTING

More information

SECTION 6-15 FIRE PROTECTION

SECTION 6-15 FIRE PROTECTION SECTION 6-15 SYSTEMS DESCRIPTION Index Page General Description... 6-15-2 Engine Fire Protection... 6-15-2 Engine Fire Detection... 6-15-2 Engine Extinguishing... 6-15-3 Engine/Wheelwell and Pipe Zone

More information

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

La Marche Manufacturing Company   Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual La Marche Manufacturing Company www.lamarchemfg.com Option 46 Series Digital Combined Accessory Package Installation and Operation Manual This manual is subject to change without notice. You may obtain

More information

DC3Training.com N28AA DC-3 Pilot s Handbook

DC3Training.com N28AA DC-3 Pilot s Handbook SECTION 7 FIRE PROTECTION Index General page 2 Operation page 4 Limitations page 4 Troubleshooting page 5 4/19/2012 crew@dc3training.com 1 GENERAL The fire protection system consists of an Edison fire

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

Memory Items 2

Memory Items 2 Flash Cards 1 Memory Items 2 Memory Items ENGINE FAILURE/EMERGENCY ENGINE SHUTDOWN 3 Memory Items ENGINE FAILURE/EMERGENCY ENGINE SHUTDOWN 1. Condition lever FUEL CUTOFF 2. Propeller lever FEATHER 3. Firewall

More information

BERMAD Fire Protection

BERMAD Fire Protection Model: 400E-3M Bermad Electro-Pneumatically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Safety First BERMAD believes that the safety of personnel working with

More information

generic moving map with bezel removed Avidyne Entegra MFD for Piper or Cirrus aircraft Avidyne Entegra PFD for Piper or Cirrus aircraft

generic moving map with bezel removed Avidyne Entegra MFD for Piper or Cirrus aircraft Avidyne Entegra PFD for Piper or Cirrus aircraft AvSimMap_II.ac Avidyne map generic moving map AvSimMap_II_nobezel.ac Avidyne map generic moving map with bezel removed AvSimMFD_all.ac Avidyne MFD Avidyne Entegra MFD for Piper or Cirrus aircraft AvSimPFD_all.ac

More information

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts Figure 1Document: SPEC-112 Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts construction requirements of UL approved Class H (180 C) insulation system. Transformers

More information

, ,

, , 796-2028, 796-2021, 796-2025 Batten mount PIR detectors Overview This series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual control

More information

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/ Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/08 Table Of Contents Section I Installation and Startup.................. 1 INSTALLATION............................................

More information

HAWKER 800XP AND 850XP ILLUSTRATED PARTS CATALOG LOCATION FILAMENT/BULB VENDOR COCKPIT LIGHTING

HAWKER 800XP AND 850XP ILLUSTRATED PARTS CATALOG LOCATION FILAMENT/BULB VENDOR COCKPIT LIGHTING 000 COCKPIT LIGHTING ENGINE START AND IGNITION DA PANEL L1338/736 /VITALITY SIDE CONSOLE SIDEWALL FLOOD LIGHTS 1820 VITALITY STORM LAMPS 12015N-13 PHILIPS BA PEDESTAL L1338/736 /VITALITY WINDSCREEN TOP

More information

SCAN200E USER S MANUAL

SCAN200E USER S MANUAL SCAN200E USER S MANUAL Code No. 2071 1052 rev. 1.4 Code No. 2071 1052 Rev. 1.4 Page 2/16 SCAN200E User s Manual Foreword This manual is for SCAN200E Controller running software version 2.03 or later. We

More information

Chapter 26 FIRE PROTECTION

Chapter 26 FIRE PROTECTION Chapter 26 FIRE PROTECTION 26-Title Page 1 INTENTIONALLY LEFT BLANK 26-Title Page 2 LIST OF EFFECTIVE PAGES Chapter Section Page No. Date 26 26-Title 1 2 26-LOEP 1 2 26-TOC 1 2 26-20 1 July 28, 2008 2

More information

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER PNEUMERCATOR Liquid Level Control Systems Electronic Systems Excluding LC2000 And TMS Series MAINTENANCE & TROUBLESHOOTING GUIDE 400 300 500 FUEL LEVEL LEAK MONITOR 1 200 600 OIL/GAS NORMAL WATER PNEUMERCATOR

More information

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual Instruction manual MTL process alarm equipment October 2016 CSM 725B rev 2 MTL RTK 725B Configuration Software Manual SECTION 1 - INTRODUCTION... 5 Basic Requirements... 5 SECTION 2 - SOFTWARE INSTALLATION...

More information

LD1000 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev

LD1000 ARCHITECT AND ENGINEER SPECIFICATIONS. RLE TECHNOLOGIES Rev LD1000 ARCHITECT AND ENGINEER SPECIFICATIONS RLE TECHNOLOGIES Rev. 1.0 110063 1. GENERAL SPECIFICATION 1.1 The contractor shall provide RLE Technologies SeaHawk LD1000 Alarm Panel (hereinafter referred

More information

Ammonia Detection System Codes and Design Specifications

Ammonia Detection System Codes and Design Specifications Ammonia Detection System Codes and Design Specifications January 15, 2018 Revision 6 Ammonia detection system codes and design specifications Following is a discussion of ammonia detection system design

More information

UNI-TROL TM GAS CONTROLLER

UNI-TROL TM GAS CONTROLLER MODELS: R1G, R2G and R4G UNI-TROL TM GAS CONTROLLER One, Two and Four-Channel Rack-Mount Controller ISO 9001 Certified Company Part Number: MAN-0004 Rev. 1 Copyright 2002 Net Safety Monitoring Inc. Printed

More information

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide PIR/INT & PIR/INT-D Batten mount PIR detectors Overview The PIR/INT & PIR/INT-D miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional

More information

EBDSPIR-PRM-LV Product Guide

EBDSPIR-PRM-LV Product Guide EBDSPIR-PRM-LV Product Guide Ceiling PIR presence/absence detector 12-24V AC/DC Overview The EBDSPIR-PRM-LV PIR (passive infrared) presence detector provides automatic control of low voltage loads including

More information

APC APPLICATION NOTE #119

APC APPLICATION NOTE #119 #119 InRow RP-CW and InRow RP-DX Environmental Control By Henry Jespersen Abstract The primary function of the InRow RP product is to cool air from the hot aisle and deliver it to the cold aisle at the

More information

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4 HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4 INTRODUCTION Thank you for purchasing the Hokkim Integrated Automatic Mains Failure Control Board model HAMF- 8 or HAMF-4. We shall

More information

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES USER INSTRUCTIONS FOR THE CHEMGARD INFRARED GAS MONITOR SERIES To completely customize the specification to your exact application, modification to the

More information

MODEL 5100 VOTING LOGIC MODULE

MODEL 5100 VOTING LOGIC MODULE DESCRIPTION DESCRIPTION The SST Model 5100 Multi-Input Voting Logic Module is used to monitor the status of up to 14 different points in a hazard zone, and report when a selectable number of these points

More information

United States Army Warfighting Center Fort Rucker, Alabama SEPTEMBER 2006

United States Army Warfighting Center Fort Rucker, Alabama SEPTEMBER 2006 United States Army Warfighting Center Fort Rucker, Alabama SEPTEMBER 2006 STUDENT HANDOUT TITLE: CH 47D ENVIRONMENTAL SYSTEMS FILE NUMBER: 011 2111-1 PROPONENT FOR THIS STUDENT HANDOUT IS: 110 th Aviation

More information

Control Panel User Guide

Control Panel User Guide Fire Detection & Alarm System Control Panel V4.14 Control Panel User Guide (TO BE RETAINED BY USER) 26-0397 Issue 6 Fike s policy is one of continual improvement and the right to change a specification

More information

Ice*Meister Model 9732-PLASTIC*

Ice*Meister Model 9732-PLASTIC* 1 Ice*Meister Model 9732-PLASTIC* Ice Detecting Sensor for Aircraft Technical Data Sheet Figure 1 Model 9732-PLASTIC aviation ice detector is a commercial, off-the-shelf, in-flight ice sensor that monitors

More information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features Product Guide EBMPIR-MB Batten mount PIR detectors Overview The EBMPIR-MB series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual

More information

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

ZX1e ZX2e ZX5e. Document No Issue 01 user manual ZX1e ZX2e ZX5e Document No. 996-130 Issue 01 user manual MORLEY-IAS ZX2E/ZX5E Fire Alarm Control Panels Table of Contents 1 INTRODUCTION... 4 1.1 NOTICE... 4 1.2 WARNINGS AND CAUTIONS... 4 1.3 NATIONAL

More information

SEC 2000 Millenium Infrared Gas Detector

SEC 2000 Millenium Infrared Gas Detector SEC 2000 Millenium Infrared Gas Detector Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952) 938-9486 Fax (952) 938-9617 Email: sales@sensorelectronic.com

More information

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117 Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel Revision E 61117 CAUTION: (Read This First) This panel has been designed to make it nearly bullet proof to mistakes made when wiring

More information

Public Safety DAS Annunciator Panel

Public Safety DAS Annunciator Panel Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

EXTINGUISHING AGENT RELEASE MODULE

EXTINGUISHING AGENT RELEASE MODULE EXTINGUISHING AGENT RELEASE MODULE Operation, Installation & Programming Manual Revision 3.00 Distributors For: 18-20 Brookhollow Ave telephone 02 8850 2888 www.firesense.com.au Baulkham Hills NSW 2153

More information

Dual Column Dehydrating Breather Manual

Dual Column Dehydrating Breather Manual Dual Column Dehydrating Breather Manual DCB-MANUAL 1.6 Read and understand this manual prior to operating or servicing the products. SPX Transformer Solutions, Inc., Service & Components Division U.S.

More information

APU FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION

APU FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION 1.General APU FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION A.The APU fire extinguishing system has controls in two locations that release one application of fire extinguishing agent to a fire

More information

CO Guardian LLC Document No E. AIRPORT DRIVE Date: 08/25/10 OWNERS MANUAL

CO Guardian LLC Document No E. AIRPORT DRIVE Date: 08/25/10 OWNERS MANUAL OWNERS MANUAL PULSE OXIMETER AND CARBON MONOXIDE DETECTOR MODEL AERO-455 Rev. B 455 MODEL OWNERS/INSTALLATION MANUAL Page 1 of 21 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION APPROVED A 1 thru 20

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 36 23 This section specifies the furnishing, complete installation, and connection of automatic transfer switches. 1.2 RELATED WORK A. Section 14 21 00, ELECTRIC

More information

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

THE SS90 SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL S S S S S S S S 90 OLID TATE ECURITIES, INC SOLID STATE FAIL-SAFE UNIT * PATENT PENDING LISTED U 99Y9 RESET L RELEASING DEVICE SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE

More information

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features Product Guide PPAD-C-230V Ceiling PIR presence/absence detector Overview The PPAD-C-230V passive infrared presence detector provides automatic control of lighting loads with optional manual control. The

More information

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL MADE IN THE U.S.A. U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION SERIAL NUMBER The Cookson Company FIREFLY II PLUS Time Delay Release

More information

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC Product Guide EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC Ceiling PIR presence/absence detector Overview The EBDSPIR-PRM-VFC PIR (passive infrared) presence detector provides automatic control of lighting loads

More information

MODEL B2 INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL RELEASE DEVICES GENERAL DESCRIPTION MODEL B2 INSTALLATION MANUAL S/N: The B2 Series Time Delay Release Devices are UL Listed, Canadian Listed, and CSFM Listed for use on rolling doors, single-slide and

More information

Be sure DC power is applied safely to terminals 3-4. Use caution during testing.

Be sure DC power is applied safely to terminals 3-4. Use caution during testing. BE1-46N SCOPE This test procedure covers the testing of the Basler BE1-46N negative sequence current relay. Refer to IM 9170000990 Rev. L (12/12) for testing support information and component level identification.

More information

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual We manage heat MANUAL Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239

More information

SmartAlarm Annunciator

SmartAlarm Annunciator Annunciator Specification/Features The Annunciator offers a modern compact DIN package that includes state of the art critical alarm capture in an industry standard footprint 1. High Intensity LED s 2.

More information

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps TT-1023 1/97 INSTALLATION INSTRUCTIONS Original Issue Date: 2/94 Model: 6-2000 kw Market: Industrial Subject: Flush- or Surface-Mount Remote Annunciator Kits PA-293991 and PA-293991-SD The remote annunciator

More information

Carey Automatic Door, LLC 1 - PNEUMATIC OPERATOR FOR SINGLE SWINGING DOOR

Carey Automatic Door, LLC 1 - PNEUMATIC OPERATOR FOR SINGLE SWINGING DOOR Carey Automatic Door, LLC 1 - PNEUMATIC OPERATOR FOR SINGLE SWINGING DOOR IN for Doors Swinging under Operator OUT for Doors Swinging away from Operator Packages 1, 2 & 3 Packages 4, 5 & 6 FACTORS TO CONSIDER

More information

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview

Water Leak Detector - Four Zone with open/short-circuit detection. Product overview Water Leak Detector - Four Zone with open/short-circuit detection Product overview The AX-WLDF is a four zone water leak detection module with open or short circuit sensor cable detection. The module must

More information

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features Product Guide VITMR-EBDSPIR-PRM PIR Presence/Absence Detector IR with Ceiling Rose Overview The VITMR-EBDSPIR-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads.

More information

Emergency Procedures Training

Emergency Procedures Training Emergency Procedures Training Agenda (classroom) Aeroplane fire in the air and on the ground Hijacking, bomb threat and other security procedures Passenger on board medical emergency Agenda (Aircraft)

More information

PURGE/PRESSURIZATION SYSTEM

PURGE/PRESSURIZATION SYSTEM PROCESS AUTOMATION PURGE/PRESSURIZATION SYSTEM DATA SHEETS Systems ( Series) 2001A: Class I Volumes 2 ft 3 and Class II Volumes 10 ft 3...3 2001B: Class II Volumes 50 ft 3...7 2001C: Class II Volumes 250

More information

DS160/161 Request To Exit PIR sensors Installation Instructions

DS160/161 Request To Exit PIR sensors Installation Instructions DS160/161 Request To Exit PIR sensors Installation Instructions 1.0 Description The DS160/161 is a passive-infrared (PIR) detector designed for request to exit (REX) interior applications. It is UL Listed

More information

Document No

Document No CO Guardian LLC 1951 E. Airport Dr. Tucson, AZ 85706 CARBON MONOXIDE DETECTOR MODEL 452 INSTALLATION AND OPERATIONAL MANUAL Document No. 01-2510-02 MODEL 452 INSTALLATION AND OPERATIONAL MANUAL Page 1

More information

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55 96239823 SWITCHLITE MRE SLD MAN 96239821 SWITCHLITE MRE SLD IP55 Overview The SWITCHLITE MRE SLD PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual

More information

FlameGard 5 MSIR HART

FlameGard 5 MSIR HART FlameGard 5 MSIR HART Multi-Spectral Infrared Flame Detector HART Communication with the FlameGard 5 Multi-spectral Infrared Detector The information and technical data disclosed in this document may be

More information

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS OWNER S MANUAL High-Wall Fan Coil Unit Page GENERAL 2,3 OPERATING MODES 2 REMOTE CONTROL 2 OPERATION 3-9 REMOTE CONTROL OPERATION 3 INDOOR UNIT DISPLAY 5 EMERGENCY OPERATION 5 PRESSING THE ON/OFF BUTTON

More information

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards Touchpoint 4 The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards Touchpoint 4 Controller User Friendly Self-contained, wall mounted enclosure

More information

Electrofilm Manufacturing Company, LLC Repair Station Part Number Capability Iist

Electrofilm Manufacturing Company, LLC Repair Station Part Number Capability Iist Electrofilm Manufacturing Company, LLC Repair Station Part Number Capability Iist FAR-125: EFKR738K & EASA 145.5242 4/26/2012 Uncontrolled Copy, Reference Only Customer Part No. Electrofilm Part No. Description

More information

Construction Electrical

Construction Electrical INDEECO offers a broad range of electrical components for temperature, safety, and power control. For most applications, the Control Option system, described in the previous section, makes it easy to specify

More information

METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS METEOROLOGICAL INSTRUMENTS INSTRUCTIONS WIND TRACKER MODEL 06206 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com

More information

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features Product Guide MWS6-PRM Ceiling microwave presence/absence detector Overview The MWS6-PRM microwave presence detector provides automatic control of lighting loads with optional manual control. The MWS6-PRM

More information

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS INSTALLATION MANUAL AND OPERATING INSTRUCTIONS MD41-1200 SERIES TERRAIN AWARENESS ANNUNCIATION CONTROL UNIT for SANDEL ST3400 TAWS MD41-1248 28vdc Horizontal Mount MD41-1258 28vdc Vertical Mount (shown

More information

Environmental Systems

Environmental Systems Environmental Systems 21-00: ENVIRONMENTAL SYSTEMS 1. General This section covers those systems and components used to furnish a means of heating, cooling, and treating the air used to ventilate the areas

More information