APU FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION
|
|
- Sharon Manning
- 5 years ago
- Views:
Transcription
1 1.General APU FIRE EXTINGUISHING SYSTEM - DESCRIPTION AND OPERATION A.The APU fire extinguishing system has controls in two locations that release one application of fire extinguishing agent to a fire in the APU compartment. The system has test capability. B.The APU fire extinguishing system includes the APU fire extinguisher bottle located forward of the APU firewall, the APU/CARGO fire control panel on pilots' aft control stand P8, the P62 APU shutdown remote control panel on the nosegear, and the squib test panel located on the P61 right side panel. C.The APU shutdown remote control panel P62 is located on the nose landing gear. P62 contains a red APU FIRE LIGHT, APU SHT DN switch, and APU BTL DISCH switch. When a fire is detected in the APU compartment, the APU FIRE LIGHT comes on, and a warning horn sounds. Pressing APU SHT DN shuts down the APU and arms the remote APU bottle discharge. Pressing APU BTL DISCH switch discharges the APU fire bottle. If APU SHT DN switch is pressed, the APU remote fire indication power must be recycled OFF and ON to reset the system, otherwise fire horn is disabled. D. E. F. G. 2.Component Details ( Ref. Figure 1) A.APU Fire Extinguisher Bottle(s) (1)One APU fire extinguisher bottle is found forward of the APU fire wall on the lower right side. The extinguisher bottle includes a squib cartridge, pressure switch, and the combined safety relief and filler port. (2)One APU fire extinguisher bottle is found forward of the APU fire wall on the lower right side. The extinguisher Page 1 of 20
2 (3) bottle includes an active squib cartridge, pressure switch, and the combined safety relief and filler port. (4)The squib cartridge located on the discharge valve, when detonated, ruptures a retaining disc in the valve releasing the extinguishing agent. (5)The APU fire extinguisher bottle (p/n ) has two discharge ports. The system only utilizes one of the discharge ports. The bottle has both squibs fitted. The inactive, unconnected squib (p/n ) is fitted with a protective cap to prevent inadvertent firing. (6)The safety relief is a thermal expansion overpressure rupture disc. If bottle pressure is too high, the safety relief ruptures, allowing the bottle to discharge. The filler port is for introducing the extinguishing agent and pressurizing gas into the bottle. (7)The extinguishing agent is bromotrifluoromethane (halon), and the pressurizing gas dry nitrogen. The agent leaves no residue when discharged. B.APU Fire Switch (1)The APU fire switch is located on the APU fire control panel at pilot's aft control stand P8. When a fire is detected in the APU compartment, the APU fire switch handle red warning light comes on. A solenoid energizes releasing a mechanical interlock on the fire switch handle shaft. When the mechanical interlock is released, the fire switch handle can be operated by pulling the handle out and rotating it. Rotating the handle releases the extinguishing agent. After rotation, the fire handle automatically returns to an off-center position. To push the handle back in it must be in the center horizontal position. The fire switch handle can be manually unlocked by pressing the button behind the handle. (2) C.APU Shutdown Remote Control Panel (1)The APU shutdown remote control panel P62 is located on the nose landing gear. P62 contains a red APU FIRE LIGHT, APU Page 2 of 20
3 (2) D.Squib Test Panel SHT DN switch, and APU BTL DISCH switch. When a fire is detected in the APU compartment, the APU FIRE LIGHT comes on, and a warning horn sounds. Pressing APU SHT DN switch shuts down the APU and arms the remote APU bottle discharge. Pressing APU BTL DISCH switch, discharges the APU fire bottle. If APU SHT DN switch is pressed, the APU remote fire indication power must be recycled OFF and ON to reset the system, otherwise fire horn is disabled. (1)The squib test panel is located on the P61 right side panel. The switches on the panel are used to check extinguisher bottle squib cartridges. When pressed, the TEST switch on the panel checks continuity of the squib cartridges. A green test light comes on for a successful test. (2) (3)The squib test panel is located on the P61 right side panel. The switches on the panel are used to check extinguisher bottlesquib cartridges. When pressed, the TEST 1 switch on the panel check circuit continuity between the APU discharge switches and squib cartridges. A green test light comes on for a successful test. Page 3 of 20
4 Figure 1. APU Fire Extinguishing System - Component Location (Sheet 1) Page 4 of 20
5 FED ALL Page 5 of 20
6 Figure 1. APU Fire Extinguishing System - Component Location (Sheet 2) FED ALL Page 6 of 20
7 Figure 1. APU Fire Extinguishing System - Component Location (Sheet 3) FED , , 928, 930, , , , 989, Page 7 of 20
8 Figure 1. APU Fire Extinguishing System - Component Location (Sheet 4) FED 964, , Page 8 of 20
9 Figure 1. APU Fire Extinguishing System - Component Location (Sheet 5) FED , , 928, 930, , , , 989, Page 9 of 20
10 Figure 1. APU Fire Extinguishing System - Component Location (Sheet 6) FED 964, Page 10 of 20
11 Figure 1. APU Fire Extinguishing System - Component Location (Sheet 7) FED , , 928, 930, , , , 989, Page 11 of 20
12 Figure 1. APU Fire Extinguishing System - Component Location (Sheet 8) FED 964, Page 12 of 20
13 Figure 1. APU Fire Extinguishing System - Component Location (Sheet 9) FED ALL WITH HEX KEY PRESSURE SWITCH - KIDDE Page 13 of 20
14 Figure 1. APU Fire Extinguishing System - Component Location (Sheet 10) FED ALL WITH PTT PRESSURE SWITCH - HTL Page 14 of 20
15 3.Operation ( Ref. Figure 2) A. Functional Description (1) When a fire is detected in the APU compartment, the APU fire switch handle red warning light comes on and the fire warning bell sounds through the aural warning speakers. The red APU FIRE light on the P62 APU shutdown remote control panel also comes on. (2) After a fire is detected in the APU compartment, a solenoid energizes releasing a mechanical interlock on the fire switch handle shaft. The handle is then operable. The mechanical interlock is manually released by pressing the button located behind the fire handle. (3) When the airplane is on the ground and a fire is detected, the APU will shut down and the fire extinguisher bottle will discharge automatically. When the airplane is in flight and a fire is detected, the APU will shut down automatically but the extinguisher bottle must be discharged manually. (4) When the APU fire switch handle is pulled out, the APU automatically shuts down and the extinguishing bottle is armed. The following also happens: the APU generator field relay and generator circuit breaker are tripped; the APU fuel shut-off valve closes; the APU air supply valve closes; the fire bell shuts off; the external fire warning horn and APU fire light on P62 shut off. (5) Decreasing bottle pressure, by discharge or leakage, activates the bottle pressure switch. The following occurs when a decrease in pressure is detected: the APU BTL DISCH light on APU/CARGO fire control panel P8 comes on, and a APU BTL DISCH message appears on the EICAS display. (6) Page 15 of 20
16 (7) (8) Extinguishing occurs when the APU fire handle is pulled out and rotated in either direction. After rotation of the handle, an electrical signal is applied to the squib cartridge of the extinguisher bottle. The electrical signal detonates the bottle squib producing a rupture in the retaining disc allowing the extinguishing agent to be released. The extinguishing agent runs to an outlet nozzle at the bottom of the APU fire wall and is discharged into the APU compartment. (9) (10) Decreasing bottle pressure, by discharge or leakage, activates the bottle pressure switch. The following occurs when a decrease in pressure is detected: the APU BTL DISCH light on APU/CARGO fire control panel P8 comes on, and a APU BTL DISCH light message appears on the EICAS display. (11) B. APU Extinguishing System Test (1) Squib Test (a) The squib test control panel checks the integrity of extinguisher bottle squibs. Pressing the TEST switch sends a signal to the squib discharge cartridge. If the squib and circuit continuity are good, the green APU light on the panel will come on. (b) The squib test control panel checks the integrity of extinguisher bottle squibs. Pressing the TEST 2 switch sends a signal to the squib discharge cartridge. If the squib and circuit continuity are good, the green APU light on the panel will come on. (c) Page 16 of 20
17 C. DELETED D. Control (2) Pressure Switch Test (a) (b) Manually activating the bottle pressure switch tests discharge light circuit continuity. When the ground test pushbutton is pressed and held, the appropriate amber APU BTL DISCH light comes on and an APU BTL message appears on the EICAS display indicating a successful test. (c) Manually activating the bottle pressure switch tests discharge light circuit continuity. When the manual override test hex key is turned 1/4 turn clockwise, the appropriate amber APU BTL DISCH light comes on and an APU BTL DISCH message appears on the EICAS display indicating a successful test. (d) (1) To place the system in operation; provide electrical power (PAGEBLOCK /201, Electrical Power Control) (2) Make sure that these circuit breakers are closed: Main Power Distribution Panel, P6 Row Col Number Name G 1 C00780 FIRE EXT APU H 1 C00778 BTL 1 ENG L FIRE EXTINGUISHING Overhead Circuit Breaker Panel, P11 Page 17 of 20
18 Row Col Number Name FED 916 B 23 C00776 FIRE DETECTION APU 1 FED , , , 928, 930, , , , 964, B 24 C00776 FIRE DETECTION APU 1 FED 916 B 24 C00785 FIRE DETECTION APU 2 FED , , , 928, 930, , , , 964, B 25 C00785 FIRE DETECTION APU 2 FED ALL B 33 C00796 APU REMOTE FIRE IND Page 18 of 20
19 Figure 2. APU Fire Extinguishing Schematic (Sheet 1) FED 964, Page 19 of 20
20 Figure 2. APU Fire Extinguishing Schematic (Sheet 2) FED , , 928, 930, , , , 989, Page 20 of 20
Engine Fire Protection System
Engine Fire Protection System 1 1 LEFT FEED BUS LEFT CB PANEL CROSSOVER RIGHT FEED LEFT CB PANEL Fire Protection ARM UNLOCK DEPLOY S T EMER O W S NORM W BOTTLE 1 ARMED PUSH LH ENG FIRE PUSH RH ENG FIRE
More informationBombardier Challenger Fire Protection
GENERAL The fire protection system is divided into two separate subsystems: Fire and overheat detection system; and Fire extinguishing system. The fire and overheat detection system includes components
More informationFokker 50 - Fire Protection
ENGINE General The engines are each equipped with a fire detection and a fire extinguishing system. The systems are controlled from the ENGINE FIRE panel, which is located at the overhead panel. Fire and
More informationSECTION 2-07 FIRE PROTECTION
SECTION 2-07 TABLE OF CONTENTS Block General... 2-07-05..01 Engine and APU Fire Protection System... 2-07-10..01 Fire/Overheat Detection... 2-07-10..01 Fire Extinguishing... 2-07-10..04 Controls and Indicators...
More informationDASSAULT AVIATION Proprietary Data
F2000EX EASY 02-26-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-26 02-26-00 TABLE OF CONTENTS 02-26-05 GENERAL Introduction Sources 02-26-10 DESCRIPTION Introduction Fire detection Fire extinguishing Portable
More informationTABLE OF CONTENTS FIRE PROTECTION. Page. 9-i
Chapter 9: Fire Protection TABLE OF CONTENTS Page Introduction...9-1 Flight Compartment Fire Warning...9-2 Fire Detecting System...9-2 Main Wheel Well Overheat Warning...9-2 Fire Agent Discharge Indication...9-2
More informationFire Extinguishing System
Fire Extinguishing System Fire Protection CAUTION CAUTION 1 EXTINGUISHER PUSH L ENGINE FIRE R FW VALVE CLOSED TO TEST R ENGINE FIRE R FW VALVE CLOSED EXTINGUISHER PUSH 2 TEST SWITCH 1 ANNUNCIATOR PANEL
More informationFIRE PROTECTION TABLE OF CONTENTS CHAPTER 9
TABLE OF CONTENTS CHAPTER 9 Page TABLE OF CONTENTS DESCRIPTION General Flight Compartment Fire Warning Fire Detecting System Wheel Well Overheat Warning Fire Agent Discharge Indication Smoke Detection
More informationSECTION 6-15 FIRE PROTECTION
SECTION 6-15 SYSTEMS DESCRIPTION Index Page General Description... 6-15-2 Engine Fire Protection... 6-15-2 Engine Fire Detection... 6-15-2 Engine Extinguishing... 6-15-3 Engine/Wheelwell and Pipe Zone
More informationWARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS
WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS The Warning and Caution systems are discussed here in conjunction with the Warning and Test Systems, primarily to cover the procedures for testing
More informationWARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS
MODEL 680 WARNING AND TEST MASTER WARNING AND MASTER CAUTION SYSTEMS The Warning and Caution systems are discussed here in conjunction with the Warning and Test Systems, primarily to cover the procedures
More informationSection - III SYSTEMS DESCRIPTION
Section - III SYSTEMS DESCRIPTION Table of Contents Hawker 800XP Pro Line Page GENERAL...4-3 Figure - Engine Fire Detection and Warning System Component Locations...4-3 CONTROLS and INDICATIONS...4-4 ENGINE
More information71717 SERIES FLAMMABLE MATERIAL LOCATIONS
71 FLAMMABLE MATERIAL LOCATIONS (tab) CAUTION: Rescue crews wearing full PPE to include SCBA s must use caution when moving across sections of aircraft that have been exposed to fatigue or fire as the
More informationDASSAULT AVIATION Proprietary Data
F2000EX EASY 02-38-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-38 02-38-00 TABLE OF CONTENTS 02-38-05 GENERAL Introduction Sources Equipment location 02-38-10 DESCRIPTION General 02-38-15 CONTROL AND INDICATION
More informationDASSAULT AVIATION Proprietary Data
F900EX EASY 02-38-00 CODDE 1 PAGE 1 / 2 TABLE OF CONTENTS 02-38 02-38-00 TABLE OF CONTENTS 02-38-05 GENERAL Introduction Sources Equipment location 02-38-10 DESCRIPTION General 02-38-15 CONTROL AND INDICATION
More informationService Bulletin No. 2930
Service Bulletin No. 2930 MODEL TYPE SECTION/GROUP DATE E / J Series Coaches Service Information 8--Engine Mar. 30, 2006 SUBJECT AMEREX FIRE SUPPRESSION SYSTEM CONDITIONS Service Information Only Description:
More informationInstrument and Control Panels
GENERAL Instrument and Control Panels 31-10: INSTRUMENT AND CONTROL PANELS 1. General A. Instrument Panel A Garmin Primary Flight Display (PFD) is mounted in the instrument panel. The Engine Start Controls
More informationFUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED
FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with
More informationDust caps, electrical connector DPM Commercially available Hoisting rope Ref. ITEL FX 572, 624, 625, 628, 631, FX ALL
FX ALL FX ALL CONTAINER, ENGINE/APU FIRE EXTINGUISHER - REMOVAL/INSTALLATION 1.General A.This procedure has the removal and installation instructions for the engine and auxiliary power unit fire extinguisher
More informationCanadair Regional Jet 100/200 - Water & Waste
INTRODUCTION The water and waste systems include potable water, lavatory waste equipment and system controls. Two potable water systems store and supply potable water to the galley and lavatory. The forward
More informationSPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM
SECTION 1 - GENERAL CONDITIONS SPECIFICATION FOR A TOTAL FLOOD I. SCOPE: This specification outlines the requirements for a Total Flood ECARO-25 TM clean agent fire suppression system utilizing HFC-125
More informationSECTION FM-200 FIRE SUPPRESSION SYSTEM
SECTION 15360 FM-200 FIRE SUPPRESSION SYSTEM 1. GENERAL SPECIFICATION 1.1 A total flooding, ADS FM-200 fire suppression system with separate nitrogen storage used for a propellant shall be installed to
More informationSPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE CHEETAH Xi 50 CONTROL PANEL SYSTEM
SECTION 1 - GENERAL CONDITIONS I. SCOPE: This specification outlines the requirements for a Total Flood ECARO-25 TM clean agent fire suppression system utilizing HFC-125 as the fire extinguishing agent
More informationPressurization System
Pressurization System FILTER N.O. PRESET SOLENOID MOISTURE DRAIN ALTITUDE LIMIT CONTROLLER ALTITUDE LIMIT CONTROLLER MOISTURE DRAIN OUTFLOW SAFETY STATIC AIR Environmental Systems RATE ALTITUDE VACUUM
More informationFokker 50 - Integrated Alerting Unit
GENERAL Failure conditions are processed by an Integrated Alerting Unit (IAU) for visual and aural presentation to the pilots. Pre-stall warning and ground proximity warning are not integrated. The IAU
More informationANSUL ANSUL AUTOMAN II-C RELEASING DEVICE
ANSUL INSTALLATION OPERATION AND MAINTENANCE MANUAL ANSUL AUTOMAN II-C RELEASING DEVICE 001799 This manual is intended for use with the ANSUL AUTOMAN II-C Releasing Device. Those who install, inspect,
More informationANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual
ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual 001799 This manual is intended for use with the ANSUL AUTOMAN Il-C Explosion-Proof Releasing Device.
More informationAUTOMATIC FIRE & EXPLOSION SUPPRESSION SYSTEM.
AUTOMATIC FIRE & EXPLOSION SUPPRESSION SYSTEM www.abdesign.org AFSS SYSTEM INACTIVE ACTIVE 12 ms 24 ms 60 ms 96 ms 120 ms 156 ms 200 ms As a result of their mission, military vehicles are exposed to hydrocarbon
More informationMODEL MW200 MODEL MW600 AIR DRYER
OPERATING MANUAL MODEL MW200 MODEL MW600 AIR DRYER Mail Address: 226A Commerce St. Tel: 303-465-3063 Broomfield, CO 80020 Fax: 303-465-9294 TABLE OF CONTENTS 1.0 GENERAL...3 2.0 SPECIFICATIONS...3 3.0
More informationDASSAULT AVIATION Proprietary Data
FALCON 7X 02-33-05 CODDE 1 PAGE 1 / 4 GENERAL ACRONYMS LIST BATT CB EPS LED LH MAU OP PPDB RH SSPC Battery Circuit Breaker Emergency Power Supply Light Emitting Diode Left Hand Modular Avionic Unit Overhead
More informationCIRRUS AIRPLANE MAINTENANCE MANUAL
EXTINGUISHING 1. DESCRIPTION The airplane is equipped with a liquefied-gas type fire extinguisher mounted within a quick-release bracket assembly. The extinguishing agent is Halon 1211/101 blend and is
More informationSAFETY INFORMATION NOTICE
No. 2854-S-00 SAFETY INFORMATION NOTICE SUBJECT: GENERAL For the attention of Ground Rescue Booklet AIRCRAFT CONCERNED Civil LP Version(s) Military EC225 Flight safety is the first priority for Airbus
More informationSPECIFICATION: ECS SERIES CLEAN AGENT FIRE SUPPRESSION SYSTEM
1. GENERAL SPECIFICATION 1.1. A total flooding, FM-200 fire suppression system, super-pressurized with dry nitrogen shall be installed to meet a minimum design concentration of %, by volume in all designated
More informationFM-200 In-Cabinet Series
1. GENERAL SPECIFICATION 1.1 A total flooding, In-Cabinet fire suppression system, employing FM-200 superpressurized with dry nitrogen shall be installed to meet a minimum design concentration of %, by
More informationSPECIFICATION: ARGONITE Engineered Fire Suppression System
1. GENERAL SPECIFICATION 1.1 A total flooding, clean agent, fire suppression system, filled with Argonite agent shall be installed to meet a minimum design concentration of %, by volume in all designated
More informationOWNERS MANUAL MODEL 451 (-101 & -201)
OWNERS MANUAL MODEL 451 (-101 & -201) Guardian Avionics CO Guardian, LLC. 1951 E Airport Drive Tucson, AZ 85756 Phone: 520-889-1177 8:00 am - 5:00 pm MST support@guardianavionics.com 2 Table of Contents
More informationSPECIFICATION: Kidde Engineered Fire Suppression System Designed for use with 3M Novec 1230 Fire Protection
1. GENERAL SPECIFICATION 1.1 A total flooding, Novec 1230 fluid, fire suppression system, super-pressurized with dry nitrogen shall be installed to meet a minimum design concentration of %, by volume in
More informationA. NFPA 2001 Standard for Clean Agent Fire Extinguishing Systems 2004 edition.
1. GENERAL SPECIFICATION 1.1 A total flooding, FM-200 fire suppression system, super-pressurized with dry nitrogen shall be installed to meet a minimum design concentration of %, by volume in all designated
More informationSD3-60 AIRCRAFT MAINTENANCE MANUAL SYSTEM - DESCRIPTION & OPERATION (PRE MOD A8005)
SD3-60 AIRCRAFT MAINTENANCE MANUAL z AMM 22.0.0.0STALL WARNING SYSTEM - DESCRIPTION & OPERATION (PRE MOD A8005) 1. Description A. General Physical and aural warning of an incipient stall condition is respectively
More informationSection - III SYSTEMS DESCRIPTION
Section - III SYSTEMS DESCRIPTION Pro Line 21 Table of Contents Page GENERAL... 7-3 SYSTEM LOGIC... 7-3 CONTROLS and ANNUNCIATIONS... 7-3 OPERATION... 7-4 STALL WARNING SYSTEM... 7-4 STALL IDENTIFICATION
More informationSECTION TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM
SECTION 13966 TOTAL FLOODING ECARO-25 CLEAN AGENT FIRE EXTINGUISHING SYSTEM Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Total
More informationSPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi 50 CONTROL PANEL
SECTION 1 - GENERAL CONDITIONS I. SCOPE: This specification outlines the requirements for a Fike Micromist Water Mist Fire Suppression System with a Cheetah Xi 50 addressable detection and control system.
More information24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY
24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 06/13/2011 Rev. 6 Pollution Control Unit PCU CORE CONNECTIONS, 3/8" NPT CONNECTION, ONE PER MODULE LINE FROM PACKAGE MUST BE BRANCHED TO EACH MODULE..
More informationDocument No
CO Guardian LLC 1951 E. Airport Dr. Tucson, AZ 85706 CARBON MONOXIDE DETECTOR MODEL 452 INSTALLATION AND OPERATIONAL MANUAL Document No. 01-2510-02 MODEL 452 INSTALLATION AND OPERATIONAL MANUAL Page 1
More informationKelly Aerospace Willoughby, OH NC , Rev. A FAA APPROVED AIRPLANE FLIGHT MANUAL SUPPLEMENT FOR LC40-550FG AIRFRAME DE-ICING SYSTEM
Aircraft SN: Aircraft Registration Number: This supplement must be attached to the FAA approved flight manual when the Kelly Aerospace airframe de-icing system is installed in accordance with STC SA02660CH.
More informationAgent Tanks PCL PCL PCL PCL - 600
Components Pg 2-1 Agent Tanks PCL - 160 PCL - 300 PCL - 460 PCL - 600 Model No. Diameter Height to top of valve Height with control head Height to valve outlet Weight PCL - 160 8.00 in. 17.65 in. 23.50
More information26 - EFFECTIVE PAGES. Beechcraft Corporation PAGE 1 HAWKER 900XP ILLUSTRATED PARTS CATALOG DATE CH-SECT-UNIT-FIG
CH-SECT-UNIT-FIG PAGE NO. DATE CH-SECT-UNIT-FIG PAGE NO. DATE 26 - CONTENTS 1 26-10-05-05 0 26-10-05-05 0A 26-10-05-05 1 26-10-05-10 0 26-10-05-10 1 26-10-05-15 0 26-10-05-15 1 26-10-05-35 0 26-10-05-35
More informationCRU-S Series Stainless Steel Condensate Recovery Unit
IM-UK-CRU-S UK Issue 1 CRU-S Series Stainless Steel Condensate Recovery Unit 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Storage, shutdown and equipment protection
More informationTJERNLUND PRODUCTS, INC.
TJERNLUND PRODUCTS, INC. 1601 Ninth Street White Bear Lake, MN 55110-6794 PHONE (800) 255-4208 (651) 426-2993 FAX (651) 426-9547 Visit our web site www.tjernlund.com PRESSURE SWITCH AND INSTALLATION WITH
More informationParts Manual. Gas Floor Type Convection Steamer. Series: SteamCraft Model 24CGA East 179 th Street Cleveland, Ohio 44110
Parts Manual Gas Floor Type Convection Steamer Series: SteamCraft Model 24CGA10 1333 East 179 th Street Cleveland, Ohio 44110 Phone: (216) 481-4900 1-800-338-2204 Fax: (216) 481-3782 www.clevelandrange.com
More informationParts and Service Manual
Section II Parts and Service Manual (70241A) CLARKE TECHNOLOGY Operator's Manual - MINI MAX Page -29- Frame and Front Cover Assembly Drawing 2/01 Page -30- CLARKE TECHNOLOGY Operator's Manual -MINI MAX
More informationSPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPUSLE VALVE, Fike FK AGENT & SHP PRO CONTROL PANEL
SECTION 1 GENERAL CONDITIONS I. SCOPE: This specification outlines the requirements for a Total Flood Clean Agent Fire Suppression System utilizing FK-5-1-12 as the fire extinguishing agent and with a
More information1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.
Issued 2006/08/01 Section 13920 Packaged Fire Pumps and Controllers Page 1 of 7 PART 1 GENERAL 1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1
More informationCanadair Regional Jet 100/200 - Lighting
1. INTRODUCTION The lighting system provides interior and exterior illumination of the aircraft and consists of: Flight Compartment Lighting Passenger Compartment Lighting Service and Maintenance Lighting
More informationT0158_ATRcouvDEF_SYSTEM42notPEC.indd COUV1 19/05/10 16:29
42-300 Introduction This Systems guide is an essential tool for all ATR flight crew and engineer to learn or review ATR systems operation. To make learning process easier, systems are introduced in a user-friendly
More informationHOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4
HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4 INTRODUCTION Thank you for purchasing the Hokkim Integrated Automatic Mains Failure Control Board model HAMF- 8 or HAMF-4. We shall
More informationIMAGE V. Parts and Service Manual
IMAGE 0V Section II Parts and Service Manual (88B) CLARKE TECHNOLOGY Image Operator's Manual Page AUTHORIZED PERSONNEL MAINTENANCE To Access Pump Motor. Remove brush housing from machine. See "Brush Motor
More informationFDF Foam Pump Controllers Features
FDF100 Diesel Engine Foam Pump Controllers 1-1 Product Description The FDF Series of Foam Pump Controllers are designed for use with foam concentrate injection, foam transfer and water mist systems for
More informationDeluge & Preac tion Systems
Deluge & Preaction Systems Deluge Systems are normally used in special hazard installations where water must be applied to an entire area for protection. They use open sprinklers or spray nozzles attached
More informationOWNERS MANUAL. CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) Guardian Avionics 1951 E. AIRPORT DRIVE TUCSON, AZ.
OWNERS MANUAL CARBON MONOXIDE DETECTOR MODELS Panel Mount & Remote Detectors (R) (353-101 and 353-201) 353 FAMILY MODEL OWNERS/INSTALLATION MANUAL Page 1 of 22 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION
More informationCSD-1 COMMERCIAL BOILER CONTROLS
SUPPLEMENTAL INSTALLATION AND OPERATING INSTRUCTIONS CSD- COMMERCIAL BOILER CONTROLS P/N 400043, Rev. A [/03] CSD- COMMERCIAL BOILER CONTROLS! WARNING Fire, explosion, asphyxiation and electrical shock
More informationsouthbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:
INSTALLATION AND OPERATION MANUAL GAS BOILERS MODELS: CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) southbend A MIDDLEBY COMPANY 1100 Old Honeycutt Road Fuquay-Varina, NC 27526 (919) 552-9161
More informationLMR Electric Fire Pump Controllers Features
1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status
More informationSPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi 50 CONTROL PANEL
SECTION 1 GENERAL CONDITIONS I. SCOPE: SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH This specification outlines the requirements for a Total Flood Clean Agent Fire Suppression System utilizing
More informationDV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts
Worldwide Contacts www.tyco-fire.com DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package General Description The TYCO DV-5 Red-E Cabinet is a pre-assembled fire protection valve package enclosed
More informationSPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM WITH IMPULSE VALVE, FK AGENT & CHEETAH Xi CONTROL PANEL
SECTION 1 GENERAL CONDITIONS I. SCOPE: SPECIFICATION FIKE CLEAN AGENT FIRE SUPPRESSION SYSTEM This specification outlines the requirements for a Total Flood Clean Agent Fire Suppression System utilizing
More informationTechnical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)
Worldwide Contacts www.tyco-fire.com DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package General Description The TYCO DV-5 Red-E Cabinet is a pre-assembled fire protection valve package enclosed
More informationChapter 26 FIRE PROTECTION
Chapter 26 FIRE PROTECTION 26-Title Page 1 INTENTIONALLY LEFT BLANK 26-Title Page 2 LIST OF EFFECTIVE PAGES Chapter Section Page No. Date 26 26-Title 1 2 26-LOEP 1 2 26-TOC 1 2 26-20 1 July 28, 2008 2
More informationLMR Electric Fire Pump Controllers Features
1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status
More informationWorldwide Contacts.
Worldwide Contacts www.tyco-fire.com DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package General Description The TYCO DV-5 Red-E Cabinet is a pre-assembled fire protection valve package enclosed
More informationUnited States Army Warfighting Center Fort Rucker, Alabama SEPTEMBER 2006
United States Army Warfighting Center Fort Rucker, Alabama SEPTEMBER 2006 STUDENT HANDOUT TITLE: CH 47D ENVIRONMENTAL SYSTEMS FILE NUMBER: 011 2111-1 PROPONENT FOR THIS STUDENT HANDOUT IS: 110 th Aviation
More informationENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS
ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS SECTION 1 GENERAL SPECIFICATIONS I. SCOPE This specification outlines the requirements for a pre-engineered
More information787 Lithium-ion Battery Events
787 Lithium-ion Battery Events A Guide for Fire Fighters 787 Battery Event 1 Discussion The 787 is equipped with two primary lithium-ion batteries, which are contained in a stainless steel enclosure with
More informationBid Specifications for Thermo-Lay model UD /4 yard truck mounted machine with hydraulic bins & roller DIMENSIONS: Body:
DIMENSIONS: Body: 142" long, 78" wide, 43" high Total Height above ground: 98" Cab to trunion required: 138" Wheel base required: 204" on Freightliner FL 70 Turning radius: 55' curb to curb on Freightliner
More informationCO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL
OWNERS MANUAL CARBON MONOXIDE DETECTOR MODELS Panel mount and Remote Detectors (R) (353 and 353R) 353 FAMILY MODEL OWNERS/INSTALLATION MANUAL Page 1 of 22 LOG OF REVISIONS REV NO. PAGE NO. DATE DESCRIPTION
More informationIEEE Transformer Committee PC Distribution Transformer Monitoring - User
IEEE Transformer Committee PC57.167 Distribution Transformer Monitoring - User Mark Scarborough Electrical Engineering Consultant DuPont January 9, 2019 Transformer Types in DuPont Control power Dry-type
More informationKEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters. Table of Contents FOR YOUR SAFETY.
KEES, INC. Installation & Maintenance Manual DFG Series Direct Gas Fired Make-up Air Heaters Table of Contents FOR YOUR SAFETY Page # Topic If you smell gas: 1 Description of Operation 1 Receiving the
More informationSPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL
SECTION 1 - GENERAL CONDITIONS I. SCOPE: This specification outlines the requirements for a Fike Micromist Water Mist Fire Suppression System with automatic detection and control. The work described in
More informationInert Gas Fire Extinguishing System
s & Equipment Manufact s & Equipment Manufact s & Equipment Manufact s & Equipment Manufact s & Equipment Manufact s & Equipment Manufact s & Equipment Manufact s & Equipment Manufact s & Equipment Manufact
More informationTT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps
TT-1023 1/97 INSTALLATION INSTRUCTIONS Original Issue Date: 2/94 Model: 6-2000 kw Market: Industrial Subject: Flush- or Surface-Mount Remote Annunciator Kits PA-293991 and PA-293991-SD The remote annunciator
More informationRANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL
RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL TABLE OF CONTENTS GENERAL DESCRIPTION... 2 STANDARD AND OPTIONAL PARTS LIST... 2 PARTS DIAGRAM... 3 TERMINAL DRAWING AND SPECIAL NOTES...
More informationDRI-AIR INDUSTRIES, INC. AHM-1C HOPPER MOUNT DRYER OPERATING MANUAL
AHM-1C HOPPER MOUNT DRYER OPERATING MANUAL Page 1 DRI-AIR INDUSTRIES, INC. 16 THOMPSON ROAD P.O. BOX 1020 EAST WINDSOR, CT 06088-1020 Tel. (860) 627-5110 FAX (860) 623-4477 Internet http://www.dri-air.com
More informationDC3Training.com N28AA DC-3 Pilot s Handbook
SECTION 7 FIRE PROTECTION Index General page 2 Operation page 4 Limitations page 4 Troubleshooting page 5 4/19/2012 crew@dc3training.com 1 GENERAL The fire protection system consists of an Edison fire
More informationFire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200
IMO fire control signs - according to IMO Resolution A.654 (16) Safety and operating instructions for trained personnel (SIS) - As per ISO 24409, SIS signs are safety-related signs that replicate the symbols
More informationCIRRUS AIRPLANE MAINTENANCE MANUAL
COOLING 1. DESCRIPTION On aircraft Serials 205 and subsequent w/ Perspective Avionics, an optional air-conditioning system is available. This section covers those systems and components used to supply
More informationCAUTION. No-Load Performance, Controls in Normal Position
Side-by-Side Refrigerator Technical Information JCD2292KT* JCD2292KT*2, JCD2295KE* JCD2295KE*2, JCD2297KE* JCD2297KE*2, JSD2695KES JSD2695KES2, JSD2695KG* JSD2695KG*0, JSD2697KE* JSD2697KE*2, MSD2660KEG*
More informationSection - III SYSTEMS DESCRIPTION
Section - III SYSTEMS DESCRIPTION Pro Line 21 Table of Contents Page GENERAL...1-3 ANNUNCIATOR TYPES...1-3 ARRANGEMENT...1-3 REPEATER ANNUNCIATORS...1-3 Figure 1 - Master Warning Annunciations and Controls...1-4
More informationTechnical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:
Worldwide Contacts www.tyco-fire.com DV-5 Red-E Cabinet Integrated Preaction Fire Protection Package General Description The TYCO DV-5 Red-E Cabinet is a pre-assembled fire protection valve package enclosed
More informationC I R R U S HEATING DESCRIPTION A. Cabin Air Heating System - Serials thru
HEATING 1. DESCRIPTION This section covers those systems and components used to supply heated air. Includes items such as heater panels and other units, indicating systems related to heater operation,
More informationSCN60 Residential Nugget Ice Machine
SCN60 Residential Nugget Ice Machine SCN60 Nugget Ice Nugget Ice What it isn t: Ice frozen in a mold What it is: A chewable ice, formed continuously by forcing soft ice thru tapered holes. Components Compared
More informationDatasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description
FIREFLEX VACTEC description This FIREFLEX VACTEC integrated fire protection system consists of a vacuum system trim totally pre-assembled, prewired and factory tested. All electrical and mechanical components
More informationCHAPTER 11 AIR CONDITIONING
CHAPER 11 AIR CONDIIONING INRODUCION his chapter describes the Citation Mustang air-conditioning systems. Information is provided on temperature-controlled pressurized air, vapor-cycle air conditioning,
More informationTechnical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:
Worldwide Contacts www.tyco-fire.com DV-5 Red-E Cabinet Integrated Preaction Fire Protection Package General Description The TYCO DV-5 Red-E Cabinet is a pre-assembled fire protection valve package enclosed
More information24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY
24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 11/12/2012 Rev. 10 Pollution Control Unit PCU CORE CONNECTIONS, 3/8" NPT CONNECTION, ONE PER MODULE LINE FROM PACKAGE MUST BE BRANCHED AND ADAPTED TO EACH
More informationTECHNICAL INFORMATION Touchtronic Clothes Dryers
TECHNICAL INFORMATION Touchtronic Clothes Dryers Includes: T1302, T1303, T1322, T1329ci T1403 & T1405 2004 Miele This page intentionally left blank. Table of Contents GENERAL INFORMATION A. Warning and
More informationINSTRUCTION MANUAL FOR DUTCHESS MODEL 260 BAGEL & BUN SLICER
INSTRUCTION MANUAL FOR DUTCHESS MODEL 260 BAGEL & BUN SLICER Table of Contents Safety Information I thru VII Uncrating Instructions 1 Introduction 2 Adjustment Instructions 3 Operating Instructions, Cleaning,
More informationCORE Protection Fire System Specification
CORE Protection Fire System Specification The CORE restaurant fire suppression system is a pre-engineered, duct and plenum water spray system in conjunction with a wet chemical, cartridge-operated, regulated
More informationM2500 Engine Controller Installation Manual
M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...
More informationTECHNICAL MANUAL TRAY DRYER
TECHNICAL MANUAL FOR TRAY DRYER MODEL TD321-3 TRAYDRYER MODEL: TD 321-3 Table of Contents Part 1 - Technical Information * Introduction * Catalogue Cut-sheet and Installation Drawing * Warranty Part 2
More informationControl Panel For Water Wash Hoods AM2
Control Panel For Water Wash Hoods AM2 For further information Call: (919) 554-1025 Or Fax: (919)554-1525 Aqua-Matic 117 Franklin Park Ave. Youngsville, NC 27506 TABLE OF CONTENTS AQUA-MATIC LIMITED WARRANTY
More information