Quality Control Acceptance Sampling Systems

Size: px
Start display at page:

Download "Quality Control Acceptance Sampling Systems"

Transcription

1 Quality Control Acceptance Sampling Systems

2 Lot-by-Lot Acceptance Sampling Plans for Attributes Devised in 1942 at Bell Labs Later became MIL-STD-105E ISO-2859 ANSI/ASQ Z1.4 Wording & terminology changes Additional tables added

3 ANSI/ASQ Z1.4 This standard is applicable to: End items Components and raw materials Operations Materials in process Supplies in storage Maintenance operations Data or records

4 ANSI/ASQ Z1.4 Intended to be used for a continuing series of lots, but may be designed for isolated lots. Standard provides for single, double, and multiple sampling plans. Provision is also provided for normal, tightened, or reduced inspection. Plan is specified by the AQL, and samplesize code.

5 ANSI/ASQ Z1.4 Normal inspection is used at the start of inspection with changes being a function of recent quality history. Tightened inspection: Generally used when producer s recent quality history has deteriorated.

6 ANSI/ASQ Z1.4 Reduced inspection: Used when the producer s recent quality history has been exceptionally good. Decision concerning what type of plan to use is left to the responsible authority. Nonconformities are classified such as critical, major

7 ANSI/ASQ Z1.4

8 Sample Size Code Letters

9 Comparison of Inspection levels = Percent of Lots Accepted (100Pa) III II I = 1/2 n II = n III = 2n I = Percent Nonconforming (100P a )

10 ANSI/ASQ Z1.4 AQL The AQL is the most important part of the standard since the AQL and sample size dictate the plan used. AQL is defined as the maximum percent nonconforming that can be considered satisfactory as a process average. Satisfactory = Producer s risk, α Usually 0.05

11 ANSI/ASQ Z1.4 AQL AQL is specified by contract or responsible authority. AQL may be determine from historical data, empirical judgment, engineering information, experimentation, producer s capability, consumer s requirements.

12 ANSI/ASQ Z1.4 AQL AQL is specified by contract or responsible authority. AQL may be determine from historical data, empirical judgment, engineering information, experimentation, producer s capability, consumer s requirements.

13 Sample Size ANSI/ASQ Z1.4 Determined by lot size and inspection level Use of sample-size code Inspection level is determined by the responsible authority.

14 Sample Size ANSI/ASQ Z1.4 Different levels of inspection provide approximately the same protection to the producer, but different protections to the consumer. Plan provides for special levels to be used where relatively small sample sizes are necessary and large sampling risks must be tolerated. (S-1, S-2, S-3, S-4)

15 Implementation ANSI/ASQ Z1.4 Determine lot size Determine inspection level Find sample-size code letter in table Determine AQL

16 Implementation cont d. ANSI/ASQ Z1.4 Determine type of sampling plan Find sampling plan in appropriate table Start with normal inspection and change to tightened or reduced based on switching rules

17 AQL What an AQL means is that as long as a supplier maintains his/her process average (% defective) at the assigned AQL or lower, there is a very high probability that shipments from that supplier, when inspected using ASQ Z1.4 sampling plans, will be accepted.

18 AQL By the same token, there is a very high probability that shipments, when inspected using ASQ Z1.4 sampling plans, will be rejected if a supplier's process average (% defective) remains higher than the assigned AQL.

19 ANSI/ASQ Z1.4 Single sampling plans Start by identification of AQL, lot size, inspection level, and type of sampling plan. Locate appropriate plan parameters in tables. Double and Multiple Sampling Similar procedures as single sampling

20 ANSI/ASQ Z1.4 Normal, Tightened, and Reduced Inspection Start with normal inspection Switching Procedures Normal to tightened Institute when 2 out of 5 consecutive lots not accepted on original inspection Tightened to normal Institute when 5 consecutive lots accepted If not, then discontinue inspection under this plan

21 ANSI/ASQ Z1.4 Switching Procedures Normal to reduced Institute when: (all of the following) Preceding 10 lots on normal inspection have been accepted Total nonconforming in preceding 10 samples is less than number identified in Table Production is at a steady rate Reduced inspection is considered desirable by responsible authority

22 ANSI/ASQ Z1.4 Switching Procedures Reduced to normal Institute when: (any of the following) A lot is not accepted Sampling procedure terminates with neither acceptance or rejection criteria have been met Production is irregular or delayed Other conditions

23 ANSI/ASQ Z1.4 Standard is designed for use where units of product are produced in a continuing series of lots or batches. If a sampling plan is desirable for a lot or batch of an isolated nature, it should be chosen based on the Limiting Quality (LQ) and consumer s risk, b. These tables are included in the standard, but not the textbook. Or use ANSI/ASQ Standard Q3

24 ANSI/ASQ Standard Q3 Standard is used for inspection of isolated lots by attributes. Provides indexed tables by Limiting Quality, LQ.

25 ANSI/ASQ Standard Q3 Two Schemes: 1. Used for lots that are isolated or mixed or that have an unknown history as far as all parties know. Lot size and LQ must be known. Nominal values of the LQ are based on b=0.10

26 ANSI/ASQ Standard Q3 Two Schemes: 2. Used when a vendor is producing a continuous stream of lots and sends one or a few to a customer who will consider them as isolated lots. Occurs frequently when purchasing small quantities of raw materials.

Statistical Testing of Electric Meters

Statistical Testing of Electric Meters Statistical Testing of Electric Meters A Presentation for the North Carolina Meter School & Conference June 25, 2003 Presented by Peter Yarger, P.E. Project Manager, Advent Design Corp. 1 What is Statistical

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60410 First edition 1973 Sampling plans and procedures for inspection by attributes This English-language version is derived from the original bilingual publication by leaving

More information

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS API MANUAL OF PETROLEUM MEASUREMENT STANDARDS Chapter 22 Testing Protocols Section 1 General Guidelines for Developing Testing Protocols for Devices Used in the Measurement of Hydrocarbon Fluids Type Testing

More information

FEDERAL SPECIFICATION LOCK EXTENSIONS (PEDESTRIAN DOOR LOCK ASSEMBLY PREASSEMBLED, PANIC AND AUXILIARY DEADBOLT)

FEDERAL SPECIFICATION LOCK EXTENSIONS (PEDESTRIAN DOOR LOCK ASSEMBLY PREASSEMBLED, PANIC AND AUXILIARY DEADBOLT) [INCH-POUND] FF-L-2890B April 17, 2012 Superseding FF-L-2890A August 1, 2004 FEDERAL SPECIFICATION LOCK EXTENSIONS (PEDESTRIAN DOOR LOCK ASSEMBLY PREASSEMBLED, PANIC AND AUXILIARY DEADBOLT) The General

More information

UNECE standard FFV-04 (CODEX STAN )

UNECE standard FFV-04 (CODEX STAN ) C0MPARISON STANDARD OF ASPARAGUS CODEX STANDARD FOR ASPARAGUS Concerning the marketing and commercial quality control asparagus I. Definition of produce This standard applies to shoots of asparagus of

More information

Supplier Handbook. InSinkErator st Street Racine, WI

Supplier Handbook. InSinkErator st Street Racine, WI Supplier Handbook InSinkErator 4700 21st Street Racine, WI 53406 262-554-5432 Table of Contents SECTION 1: Introduction... 2 1.1 InSinkErator... 2 1.2 InSinkErator Expectations for a Suppliers Quality

More information

UNITED STATES DEPARTMENT OF AGRICULTURE FOREST SERVICE SPECIFICATION FOR LED HEADLAMP, FIREFIGHTER

UNITED STATES DEPARTMENT OF AGRICULTURE FOREST SERVICE SPECIFICATION FOR LED HEADLAMP, FIREFIGHTER Specification 5100-451 April 2012 UNITED STATES DEPARTMENT OF AGRICULTURE FOREST SERVICE SPECIFICATION FOR LED HEADLAMP, FIREFIGHTER Comments and suggestions related to this standard should be addressed

More information

CODEX STANDARD FOR ASPARAGUS CODEX STAN

CODEX STANDARD FOR ASPARAGUS CODEX STAN CODEX STAN 225-2001 Page 1 of 6 1. DEFINITION OF PRODUCE CODEX STANDARD FOR ASPARAGUS CODEX STAN 225-2001 This Standard applies to shoots of commercial varieties of asparagus grown from Asparagus officinalis

More information

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products 1.0 Scope This specification covers the design, performance and qualification requirements for Raychem Side Entry Insulation Damage Repair Sleeve. 1.1 Description. Raychem SEIDRS covered by this specification

More information

Code of Practice Version 2 Metal Detection and X-Ray Systems

Code of Practice Version 2 Metal Detection and X-Ray Systems Code of Practice Version 2 Metal Detection and X-Ray Systems Contents Page No. 1. Introduction & Objective 3 2. Risk Assessment & General Requirements 4 3. Location 5 4. Sensitivity 6 5. Detection Operation

More information

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies

GR-326-CORE Singlemode Optical Connectors and Jumper Assemblies Preface...Preface 1 1. Introduction... 1 1 1.1 Purpose and Scope... 1 1 1.2 Target Audience... 1 2 1.3 Structure and Use of This Document...1 2 1.4 Changes from Issue 2 of GR-326-CORE... 1 3 1.5 Requirements

More information

UNECE STANDARD FFV-04 concerning the marketing and commercial quality control of ASPARAGUS

UNECE STANDARD FFV-04 concerning the marketing and commercial quality control of ASPARAGUS UNITED NATIONS ECONOMIC COMMISSION FOR EUROPE INF. 16 UNECE STANDARD FFV-04 concerning the marketing and commercial quality control of ASPARAGUS 2010 EDITION UNITED NATIONS New York and Geneva, 2010 Page

More information

FORM ACCL-PC1 ACCL WITNESS TEST PROCEDURE AND CHECKLIST

FORM ACCL-PC1 ACCL WITNESS TEST PROCEDURE AND CHECKLIST FORM ACCL-PC1 ACCL WITNESS TEST PROCEDURE AND CHECKLIST AHRI CERTIFICATION PROGRAM FOR AIR-COOLED WATER-CHILLING PACKAGES USING THE VAPOR COMPRESSION CYCLE ACCL Participant: Date of Test: Witness Test

More information

Overview of Emerging Safety Standards Machinery Sector By Phill Carroll Business Development Manager Topics Historical Situation Introduction of New Standards Terminology Safety Integrity identification

More information

DETAIL SPECIFICATION. EXTINGUISHER, FIRE, HALOCARBON (HFC-236fa), PORTABLE, WITH MOUNTING BRACKET, FOR AVIATION USE

DETAIL SPECIFICATION. EXTINGUISHER, FIRE, HALOCARBON (HFC-236fa), PORTABLE, WITH MOUNTING BRACKET, FOR AVIATION USE INCH-POUND 15 March 2007 DETAIL SPECIFICATION EXTINGUISHER, FIRE, HALOCARBON (HFC-236fa), PORTABLE, WITH MOUNTING BRACKET, FOR AVIATION USE This specification is approved for use by the Naval Air Systems

More information

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 PPE-R/00.017 Version 2 RECOMMENDATION FOR USE Number of pages: 5 Approval stage : Approved on : Origin : Horizontal Committee, C2D Ad hoc group

More information

CERTIFICATION SAFETY & BEYOND

CERTIFICATION SAFETY & BEYOND CERTIFICATION SAFETY & BEYOND Ferhun Emeksiz & R.M ( Max) Bradbury Client Manager & Fire Products Program Manager Global-Mark Pty Ltd Content Product Certification Understanding the framework Fundamental

More information

Microgrid Fault Protection Based on Symmetrical and Differential Current Components

Microgrid Fault Protection Based on Symmetrical and Differential Current Components Microgrid Fault Protection Based on Symmetrical and Differential Current Components Prepared for Public Interest Energy Research California Energy Commission Prepared by Hassan Nikkhajoei and Robert H.

More information

Supplier Handbook. InSinkErator st Street Racine, WI

Supplier Handbook. InSinkErator st Street Racine, WI Supplier Handbook InSinkErator 4700 21st Street Racine, WI 53406 262-554-5432 Table of Contents SECTION 1: Introduction... 2 1.1 InSinkErator... 2 1.2 InSinkErator Expectations for a Suppliers Quality

More information

GASTEC QA. Approval Requirements 6

GASTEC QA. Approval Requirements 6 KE 6 March 2012 GASTEC QA Approval Requirements 6 for the GASTEC QA product certificate for Plumbing fittings with ends for capillar soldering and/or thread connections Foreword These GASTEC QA Approval

More information

SolderSleeve Insulated Electrical Termination Devices

SolderSleeve Insulated Electrical Termination Devices Tyco Electronics Corporation 300 Constitutional Drive Menlo Park, CA 94025 USA Specification This Issue: Date: Replaces: RT-1404 ISSUE 9 April 20, 2000 ISSUE 8 1.0 INTRODUCTION SolderSleeve Insulated Electrical

More information

PQS Quality Assurance protocol. TITLE: Cold Room/Freezer Room:

PQS Quality Assurance protocol. TITLE: Cold Room/Freezer Room: PQS Quality Assurance protocol WHO/XXX Original: English Distribution: General TITLE: Cold Room/Freezer Room: Note that this protocol is intended to form part of the contract documentation for a new cold

More information

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA

Paul Kotrappa, Ph.D. and Carolyn Allen. Rad Elec Inc., 5714-C Industry Lane, Frederick, MD USA 177 REVIEW OF QA\QC ASPECTS OF ELECTRET ION CHAMBERS- MANUFACTURING PRACTICES AND PERFORMANCE IN WORLDWIDE INTER-COMPARISON EXERCISES IN THE PAST EIGHT YEARS Paul Kotrappa, Ph.D. and Carolyn Allen Rad

More information

GASTEC QA. Approval Requirements 69-1

GASTEC QA. Approval Requirements 69-1 KE 69-1 May 2014 GASTEC QA Approval Requirements 69-1 for the GASTEC QA product certificate for Manually operated ball valves and closed bottom taper plug valves for gas installations for buildings Foreword

More information

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION DET-TRONICS SPECIFICATION DATA Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION The EQ2200UVHT UV Flame Detector is used with the Eagle Quantum

More information

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF PORTABLE FIRE EXTINGUISHER- PERFORMANCE AND CONSTRUCTION AS PER IS 15683: 2006

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF PORTABLE FIRE EXTINGUISHER- PERFORMANCE AND CONSTRUCTION AS PER IS 15683: 2006 SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF PORTABLE FIRE EXTINGUISHER- PERFORMANCE AND CONSTRUCTION AS PER IS 15683: 2006 1. LABORATORY 1.1 A Laboratory shall be maintained which shall be suitably

More information

GASTEC QA. Approval Requirements 31-2

GASTEC QA. Approval Requirements 31-2 KE 31-2 March 2012 GASTEC QA Approval Requirements 31-2 for the GASTEC QA product certificate for Sealing materials for metallic threaded joints in contact with 2nd and 3rd family gases and hot water Part

More information

GASTEC QA. Approval Requirements 31-1

GASTEC QA. Approval Requirements 31-1 KE 31-1 March 2012 GASTEC QA Approval Requirements 31-1 for the GASTEC QA product certificate for Sealing materials for metallic threaded joints in contact with 2nd and 3rd family gases and hot water Part

More information

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Rancho Cucamonga Fire Protection District Prevention Bureau Standard Rancho Cucamonga Fire Protection District Prevention Bureau Standard Title: Fire Alarm and Monitoring Systems Standard # 9-3 Effective: May 2002 Number of Pages: 7 Updated: December 2016 for consistency

More information

IGS-M-SF-01(0) IGS. Iranian Gas Standards. CO2 Fire Extinguisher, Portable Type

IGS-M-SF-01(0) IGS. Iranian Gas Standards. CO2 Fire Extinguisher, Portable Type APPROVED 1388 IGS Iranian Gas Standards!" CO2 Fire Extinguisher, Portable Type. Fax:(9821)-8131-5679 3 4567 89:;?@8>: A;BC=D7 4EF< G@H 4I JKL 89:;M A8N=> OI http://igs.nigc.ir/igs igs@nigc.ir Table

More information

Fire alarm provisions for alerting the Fire Service

Fire alarm provisions for alerting the Fire Service Determination No. 2005/64 Fire alarm provisions for alerting the Fire Service 1 THE MATTER TO BE DETERMINED 1.1 This is a determination under section 17 of the Building Act 1991 ( the Act ) as amended

More information

Agenda Item 4. European Union Mixed Competence Member States Vote. Original text Proposed text Reason for the change / inclusion

Agenda Item 4. European Union Mixed Competence Member States Vote. Original text Proposed text Reason for the change / inclusion Agenda Item 4 CRD3 Paragraph and section number JOINT FAO/WHO FOOD STANDARDS PROGRAMME CODEX COMMITTEE ON FRESH FRUITS AND VEGETABLES 20 th Session Kampala, Uganda, 2 6 October, 2017 COMMENTS ON DRAFT

More information

Performance Rating of Heat Pump Pool Heaters

Performance Rating of Heat Pump Pool Heaters ANSI/AHRI Standard 1160 (formerly ARI Standard 1160) 2008 Standard for Performance Rating of Heat Pump Pool Heaters IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not certify or

More information

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012 KE 191 - A1 March 2012 GASTEC QA Evaluation Guideline KE 191 Amendment A1 Excess flow valves Foreword and introduction These GASTEC QA Approval requirements amendment have been accepted by the Board of

More information

Dated 15-Dec-2000; J. Schilz, subject to change

Dated 15-Dec-2000; J. Schilz, subject to change product data infrared sources preliminary! Infrared source 5 V, 115 ma, 3.17 mm diameter Features: - Incandescent infrared source up to 4.4 µm, - high reliability, - stable output, - short time constant.

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli 620014, TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT ENQUIRY NOTICE INVITING TENDER Phone:

More information

DTW Master Specification Section EMCS: Start Up, Verification and Commissioning

DTW Master Specification Section EMCS: Start Up, Verification and Commissioning Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Related Sections..1 The contractor is to ensure that all related work is co ordinated among all specification sections, as well as between Division 11,

More information

UNECE STANDARD FFV-22 concerning the marketing and commercial quality control of LETTUCES, CURLED-LEAVED ENDIVES AND BROAD-LEAVED (BATAVIAN) ENDIVES

UNECE STANDARD FFV-22 concerning the marketing and commercial quality control of LETTUCES, CURLED-LEAVED ENDIVES AND BROAD-LEAVED (BATAVIAN) ENDIVES UNECE STANDARD FFV-22 concerning the marketing and commercial quality control of LETTUCES, CURLED-LEAVED ENDIVES AND BROAD-LEAVED (BATAVIAN) ENDIVES 2012 EDITION UNITED NATIONS New York and Geneva, 2012

More information

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information UL 2360 Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction General Information UL 2360 - Test Methods for Determining the Combustibility

More information

Performance Rating of Active Chilled Beams

Performance Rating of Active Chilled Beams AHRI Standard 1241 (SI) 2016 Standard for Performance Rating of Active Chilled Beams IMPORTANT SAFETY RECOMMENDATIONS AHRI does not set safety standards and does not certify or guarantee the safety of

More information

Performance Rating of Heat Pump Pool Heaters

Performance Rating of Heat Pump Pool Heaters ANSI/AHRI Standard 1161 (SI) 2014 Standard for Performance Rating of Heat Pump Pool Heaters Approved by ANSI on 20 November 2014 IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does

More information

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment KE 192 - A1 March 2012 GASTEC QA Evaluation Guideline KE 192 Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment Foreword and introduction These GASTEC QA Approval

More information

Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units

Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units ANSI/AHRI Standard 366 (SI) 2009 Standard for Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units Approved by ANSI on 4 January 2011 IMPORTANT SAFETY DISCLAIMER AHRI

More information

Summer Works Scheme 2010

Summer Works Scheme 2010 WCMS 01/2009 TO: PRIMARY AND POST PRIMARY SCHOOL AUTHORITIES Summer Works Scheme 2010 Devolved Capital Grants for Water Conservation Measures in Primary and Post Primary School Buildings Guide for School

More information

GASTEC QA. Approval Requirements 136

GASTEC QA. Approval Requirements 136 KE 136 January 2012 GASTEC QA Approval Requirements 136 for the GASTEC QA product certificate for Polyethylene (PE) valves for plastic piping systems for the supply of gaseous fuels Foreword These GASTEC

More information

PIP PCTPA001 Testing of Process Analyzer Systems

PIP PCTPA001 Testing of Process Analyzer Systems January 2016 Process Control PIP PCTPA001 Testing of Process Analyzer Systems PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice

More information

GASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE)

GASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE) KE 200 March 2012 GASTEC QA Approval Requirements 200 for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE) Foreword These GASTEC QA Approval requirements have

More information

ANSI/AHRI Standard 911 (SI) 2014 Standard for Performance Rating of Indoor Pool Dehumidifiers

ANSI/AHRI Standard 911 (SI) 2014 Standard for Performance Rating of Indoor Pool Dehumidifiers ANSI/AHRI Standard 911 (SI) 2014 Standard for Performance Rating of Indoor Pool Dehumidifiers Approved by ANSI on July 8, 2016 IMPORTANT SAFETY DISCLAIMER AHRI does not set safety standards and does not

More information

TESTS OF ADSIL COATING

TESTS OF ADSIL COATING TESTS OF ADSIL COATING Test B - Long Term Test FSEC-CR-1259-01 July 11, 2001 Prepared for: Bob Suggs Florida Power & Light Company 9250 W. Flagler Street Miami, Florida 33174 Principal Investigator Dr.

More information

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units PAGE 1/32 Summary This document (_r2) updates the previous one (_r1) issued on Mar 08. Revised items are identified by using: 2 (1 Location). This Advanced Products News introduces the new line-up of KPI-(502~2002)E1E

More information

BUREAU OF INDIAN STANDARDS ( CENTRAL MARKS DEPARTMENT-III ) Our Ref: CMD-III/16:

BUREAU OF INDIAN STANDARDS ( CENTRAL MARKS DEPARTMENT-III ) Our Ref: CMD-III/16: BUREAU OF INDIAN STANDARDS ( CENTRAL MARKS DEPARTMENT-III ) Our Ref: CMD-III/16:2878 03-12-2007 Subject: Implementation of Amendment No 4 August 2007 to IS 2878:2004 For Fire Extinguishers, Carbon Dioxide

More information

POTENTIAL FAILURE MODE AND EFFECTS ANALYSIS (PROCESS PFMEA) Page 1 of 1

POTENTIAL FAILURE MODE AND EFFECTS ANALYSIS (PROCESS PFMEA) Page 1 of 1 POTENTIAL FAILURE MODE AND EFFECTS ANALYSIS (PROCESS PFMEA) P/N or Item: Eng. Revision: FMEA Number: Part Name: Process Responsibility Prepared by: Model Year(s)/Vehicle(s) Key Date Date (Orig.) Core Team:

More information

PLANT VARIETY (POTATO SEED) REGULATIONS [ARRANGEMENT OF REGULATIONS]

PLANT VARIETY (POTATO SEED) REGULATIONS [ARRANGEMENT OF REGULATIONS] SUBSIDIARY LEGISLATION PLANT VARIETY (POTATO SEED) REGULATIONS [ARRANGEMENT OF REGULATIONS] Regulation 1. Title 2. Interpretation 3. Act to apply to potato seed 4. Certification ofpotato seed 5. Registration

More information

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3. Rev. 1 03/05/2015 ANNEX A to the Yokogawa Corporation of America Quality Assurance Manual For Additional Requirements selectively applied to ATEX and IECEx certified products CONTENTS 1. Scope 2. Purpose

More information

Standard For Acceptance Ansi Neta Ats 2017

Standard For Acceptance Ansi Neta Ats 2017 STANDARD FOR ACCEPTANCE ANSI NETA ATS 2017 PDF - Are you looking for standard for acceptance ansi neta ats 2017 Books? Now, you will be happy that at this time standard for acceptance ansi neta ats 2017

More information

GASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012

GASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012 KE 15 January 2012 GASTEC QA Approval Requirements 15 for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas Foreword These GASTEC QA Approval requirements have been

More information

SKAPS GEOTEXTILE SUBSURFACE DRAINAGE

SKAPS GEOTEXTILE SUBSURFACE DRAINAGE SKAPS INDUSTRIES 335 Athena Drive, Athens, GA 30601 Ph: (706)-354-3700 Fax: (706)-354-3737 Email: contact@skaps.com DROP-IN SPECIFICATIONS SKAPS GEOTEXTILE SUBSURFACE DRAINAGE The following drop-in specification

More information

ASHRAE Standard 62 Ventilation Report Technical Assignment #1. Calvert Memorial Hospital Prince Frederick, MD

ASHRAE Standard 62 Ventilation Report Technical Assignment #1. Calvert Memorial Hospital Prince Frederick, MD ASHRAE Standard 62 Ventilation Report Technical Assignment #1 Prepared By: Holly Mawritz October 6, 2004 Table Of Contents: Executive Summary 2 Assumptions 3 Procedure 4 Sample Calculations 5 System and

More information

Standard Specification for Hardened Steel Washers [Metric] 1

Standard Specification for Hardened Steel Washers [Metric] 1 Designation: F 436M 93 (Reapproved 2000) METRIC Standard Specification for Hardened Steel Washers [Metric] 1 This standard is issued under the fixed designation F 436M; the number immediately following

More information

SEC 2000 Millenium Infrared Gas Detector

SEC 2000 Millenium Infrared Gas Detector SEC 2000 Millenium Infrared Gas Detector Instruction and Operation Manual Sensor Electronics Corporation 5500 Lincoln Drive Minneapolis, Minnesota 55436 USA (952) 938-9486 Fax (952) 938-9617 Email: sales@sensorelectronic.com

More information

Standard Specification for Hardened Steel Washers [Metric] 1

Standard Specification for Hardened Steel Washers [Metric] 1 Designation: F 436M 03 METRIC Standard Specification for Hardened Steel Washers [Metric] 1 This standard is issued under the fixed designation F 436M; the number immediately following the designation indicates

More information

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD ISBN 978-0-626-34241-8 SOUTH AFRICAN NATIONAL STANDARD Industrial body belts Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001 Tel: +27 12 428 7911 Fax: +27

More information

INSPECTION REPORT Nr IDD/S-09/922

INSPECTION REPORT Nr IDD/S-09/922 Page: 1/7 PROJECT: TPI For Sheet Pile BV Client: Manufacturer: Nanjing Grand Steel Piling Co., Ltd. Inspection requested by: Ref: P/o nr: (client to BV) P/o nr: GP09111101 (client to Manufacturer) SUPPLY

More information

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015?

How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015? Plumis White Paper April 2017 How to know if a residential or domestic water mist system is performance compliant to BS 8458:2015? As with the introduction of every new formal product category through

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 1555-7 April 2003 ICS 23.040.01; 91.140.40 English version Plastics piping systems for the supply of gaseous fuels - Polyethylene

More information

AASHTO s National Transportation Product Evaluation Program (NTPEP) Evaluation Program for Plants Producing Geotextiles. Pre-Audit Application Form

AASHTO s National Transportation Product Evaluation Program (NTPEP) Evaluation Program for Plants Producing Geotextiles. Pre-Audit Application Form Please provide the following information and return responses to AASHTO. Provide all applicable supporting documentation requested. Plant Name: Physical Address: Mailing Address: (if different from above)

More information

PRIVATE FIRE SERVICE INSTALLATION PACKET

PRIVATE FIRE SERVICE INSTALLATION PACKET PRIVATE FIRE SERVICE INSTALLATION PACKET The 2017 Edition supersedes all previous versions for Private Fire Service Installation To Whom It May Concern: SUBJECT: PRIVATE FIRE SERVICE INSTALLATION Illinois

More information

Conformity assessment procedures for the Alarm Components Scheme

Conformity assessment procedures for the Alarm Components Scheme Conformity assessment procedures for the Alarm RD_070, Issue 20 This guide describes the conformity assessment procedures for Alarm Components. This Alarm certifies that Alarm Components comply with technical

More information

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY Seville, 31.03.2016 Pedro Martin, RadLab Radiation Facility Supervisor TÜV NORD GROUP QUALITY ASSURANCE AND SAFETY «Anything that can go

More information

FLUID POWER ENERGY, INC. W229 N591 Foster Court Waukesha, WI THERMOSTATIC VALVES. Instruction and Application Guidelines

FLUID POWER ENERGY, INC. W229 N591 Foster Court Waukesha, WI THERMOSTATIC VALVES. Instruction and Application Guidelines THERMOSTATIC VALVES Instruction and Application Guidelines Your FPE Thermostatic Valve has been manufactured with extreme care and tested to insure that it had no detectable defects at the time it left

More information

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015 International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015 ISSN: 2289-4152 Performance Evaluation of Vapour Compression Refrigeration System Using Double Effect Condensing

More information

When Precision is not good enough

When Precision is not good enough When Precision is not good enough Andrew Kelley XACT PCB Ltd North Shields, UK Abstract As PCB designs become ever more complex with more sequential build up layers, tighter annular ring designs and broader

More information

SELF PRESERVATION SOCIETY By Jim Creak

SELF PRESERVATION SOCIETY By Jim Creak SELF PRESERVATION SOCIETY By Editor of the Means of Escape Magazine and Chairman of The Health & Safety Signs Association. w w w. m e a n s - of- e s c a p e. c o m Agenda Regulatory Reform Fire Safety

More information

PERFORMANCE EVALUATION OF DIFFERENT GREEN ROOF DESIGNS CHENGDU, CHINA

PERFORMANCE EVALUATION OF DIFFERENT GREEN ROOF DESIGNS CHENGDU, CHINA PERFORMANCE EVALUATION OF DIFFERENT GREEN ROOF DESIGNS CHENGDU, CHINA Richard L. Stanford, P.E., Dr. Shaw L. Yu, Liu Ruifen, Richard Field, PE, D. WRE, DEE, Anthony N. Tafuri, Lin Luo and Yun Deng Layout

More information

ISO INTERNATIONAL STANDARD. Fire-resistance tests Elements of building construction Part 1: General requirements

ISO INTERNATIONAL STANDARD. Fire-resistance tests Elements of building construction Part 1: General requirements INTERNATIONAL STANDARD ISO 834-1 First edition 1999-09-15 Fire-resistance tests Elements of building construction Part 1: General requirements Essai de résistance au feu Éléments de construction Partie

More information

ME 354 THERMODYNAMICS LAB THE REFRIGERATION CYCLE

ME 354 THERMODYNAMICS LAB THE REFRIGERATION CYCLE Due date for write-up: March 2, 2012 1 ME 354 THERMODYNAMICS LAB THE REFRIGERATION CYCLE INTRODUCTION: The attached figure shows schematically the refrigeration unit located in the Heat Transfer Lab, E3-2108.

More information

ISO/TS TECHNICAL SPECIFICATION

ISO/TS TECHNICAL SPECIFICATION Provläsningsexemplar / Preview TECHNICAL SPECIFICATION ISO/TS 22391-7 First edition 2011-11-15 Plastics piping systems for hot and cold water installations Polyethylene of raised temperature resistance

More information

SECURIT 700L USER MANUAL

SECURIT 700L USER MANUAL SECURIT 700L USER MANUAL C & K Systems Ltd 6/12/95 Securit 700L User instructions This manual will give you all the information you need to operate and control the Securit 700L Control Panel. This manual

More information

CONNECTION, ENERGISING, COMMISSIONING AND PERMANENT DISCONNECTION OF HIGH VOLTAGE APPARATUS

CONNECTION, ENERGISING, COMMISSIONING AND PERMANENT DISCONNECTION OF HIGH VOLTAGE APPARATUS 1. SCOPE This document details the procedures to be followed when HV Apparatus is to be connected, energised and commissioned to the System, or Permanently Disconnected from the System and when the Safety

More information

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase General Specification 550 VA/Watts 1300 VA/Watts 1.0 GENERAL This specification defines the electrical and mechanical characteristics

More information

Vulcanised rubber products for cold and hot drinking water applications

Vulcanised rubber products for cold and hot drinking water applications Product certificate K43802/06 Issued 2017-11-01 Replaces K43802/05 Page 1 of 6 Vulcanised rubber products for cold and hot drinking water applications STATEMENT BY KIWA With this product certificate, issued

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61479 Edition 1.1 2002-06 Edition 1:2001 consolidated with amendment 1:2002 Live working Flexible conductor covers (line hoses) of insulating material IEC 2002 Copyright - all

More information

PROJ. NO SECTION PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS

PROJ. NO SECTION PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS SECTION 26 92 50 PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM) Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay 905-0005-01 (100/25 PPM) 905-0005-02 (200/35 PPM) 1. INTRODUCTION Your COSTAR VC carbon monoxide detecting ventilation

More information

Alarms Updated 03/26/2018

Alarms Updated 03/26/2018 Updated 03/26/2018 Table of Contents Alarms Alarms in OneView...1 Types of Alarms...1 Setting up Alarms...2 Alarm Configuration...4 Customize Alarm Parameters...5 List of Configured Alarms...7 Acknowledging

More information

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS... TITLE SPECIFICATION FOR PHOTOELECTRIC CONTROL UNITS (PECUs) REFERENCE REV DATE: JUNE 2017 PAGE: 1 OF 16 REVISION DATE: Table of Contents FOREWORD... 3 INTRODUCTION... 4 1 SCOPE... 4 2 NORMATIVE REFERENCES...

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60903 Second edition 2002-08 Live working Gloves of insulating material This English-language version is derived from the original bilingual publication by leaving out all French-language

More information

The requirements of BS Watermist Fire System standard and how to demonstrate compliance

The requirements of BS Watermist Fire System standard and how to demonstrate compliance The requirements of BS8489-1 Watermist Fire System standard and how to demonstrate compliance Bob Whiteley C. Eng.; F.I.Mech.E.; M.I.Fire E.; B.Tech(Hons) Chair: BSI Watermist Working Group Overview What

More information

Standard ECMA th Edition - December Declared Noise Emission Values of Information Technology and Telecommunications Equipment

Standard ECMA th Edition - December Declared Noise Emission Values of Information Technology and Telecommunications Equipment Standard ECMA-109 4 th Edition - December 1996 Standardizing Information and Communication Systems Declared Noise Emission Values of Information Technology and Telecommunications Equipment Phone: +41 22

More information

A Study on Process Capability on Connecting Rod in Assembly Line

A Study on Process Capability on Connecting Rod in Assembly Line International Journal of Industrial Engineering and Technology. ISSN 0974-3146 Volume 8, Number 1 (2016), pp. 1-16 International Research Publication House http://www.irphouse.com A Study on Process Capability

More information

Drexan Energy Systems Inc.

Drexan Energy Systems Inc. Drexan Energy Systems Inc. SPECIFICATION Self-Regulating Heating Cable PipeGuard Warm Page 1 of 8 CONTENTS 1. SCOPE 2. PRODUCTS 3. TESTING 4. MARKINGS 5. PACKING 6. GENERAL 7. INSTALLATION AND COMMISSIONING

More information

BUREAU OF INDIAN STANDARDS CENTRAL MARKS DEPARTMENT-III

BUREAU OF INDIAN STANDARDS CENTRAL MARKS DEPARTMENT-III BUREAU OF INDIAN STANDARDS CENTRAL MARKS DEPARTMENT-III Our Ref: CMD-III/16:15683 02/04/2013 Subject: Implementation of Modified Scheme of Testing and Inspection Doc: STI/15683/2, as per :2006 for the

More information

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL FIRE CONTROL PANEL MAG2/4 USER MANUAL AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 READ THIS MANUAL BEFORE CONNECTING THE EQUIPMENT AND KEEP IT SAFE FOR FUTURE REFERENCE. To call our technical support

More information

Revision Date Responsible Person Description of Change

Revision Date Responsible Person Description of Change Fraser, MI 48026 Date: 12/13/16 Page 2 of 18 Revision History Revision Date Responsible Person Description of Change Original 01/25/01 Randle E. Borieo A 11/05/01 Randle E. Borieo B 10/14/03 Randle E.

More information

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions Joint 18th IHPC and 12th IHPS, Jeju, Korea, June 12-16, 2016 Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions Jens Weyant

More information

Performance Rating of Unit Ventilators

Performance Rating of Unit Ventilators AHRI Standard 840 (I-P) 1 2015 Standard for Performance Rating of Unit Ventilators Price $10.00 (M) $20.00 (NM) Printed in U.S.A. Office Copyright 2009, by Air-Conditioning and Refrigeration Institute

More information

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING Page 1 of 10 CONTENTS 1 SCOPE 2 DEFINITIONS 2.1 SURGE ARRESTER 2.2 GAPLESS METAL-OXIDE SURGE ARRESTERS 2.3

More information

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax TC-324B Manual, Rev. 05.01.31 Single Channel Heater Controller Model TC-324B 1125 Dixwell Avenue, Hamden, CT 06514 (800) 599-4203 / (203) 776-0664 (203) 776-1278 - fax TC-324B Manual, Rev. 05.01.31 TC-324B

More information

Leadax B.V. Covenant K93792/02. Leadax

Leadax B.V. Covenant K93792/02. Leadax 561/170522 Covenant K93792/02 Uitgegeven 2017-12-01 Vervangt K93792/01 Pagina 1 of 5 VERKLARING VAN KIWA With this Covenant, issued in accordance with the Kiwa Regulations for Product Certification, Kiwa

More information

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU GNB-CPR AG Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU NB-CPR/AG/03/002r3 Issued: 24 May 2013 APPROVED GUIDANCE GNB-CPR AG position paper Guidance to

More information