Vulcanised rubber products for cold and hot drinking water applications
|
|
- Abel Gaines
- 5 years ago
- Views:
Transcription
1 Product certificate K43802/06 Issued Replaces K43802/05 Page 1 of 6 Vulcanised rubber products for cold and hot drinking water applications STATEMENT BY KIWA With this product certificate, issued in accordance with the Kiwa Regulations for Certification, Kiwa declares that legitimate confidence exists that the products supplied by LOPIGOM S.r.l. as specified in this product certificate and marked with the Kiwa -mark in the manner as indicated in this product certificate may, on delivery, be relied upon to comply with Kiwa evaluation guideline BRL- dated inclusive amendment sheet dated Luc Leroy Kiwa 287/ Publication of this certificate is allowed. Advice: consult in order to ensure that this certificate is still valid. Kiwa Nederland B.V. Sir Winston Churchill-laan 273 Postbus AB RIJSWIJK The Netherlands Tel Fax info@kiwa.nl Company LOPIGOM S.r.l. Via Rossini CREDARO Italy Tel Certification process consists of initial and regular assessment of: quality system product
2 page 2 of 6 PRODUCT SPECIFICATION The products as specified in the table below fulfil the requirements of BRL-K BRL-K17504 covers the requirements of EN 681-1, - Materials requirements for pipe joint seals used in water and drainage applications - TECHNICAL SPECIFICATION OF THE PRODUCT Rubber Compound: EPDM Lopi 50 Ozone Class 1 : 50 IRHD I Seal type Cross sections application 2 : O-ring 2-10 mm II WB Rubber Compound: EPDM Lopi IRHD Ozone Class 1 : I Seal type Cross sections application 2 : O-ring 2-10 mm II WB Rubber Compound: EPDM Lopi IRHD application 2 II WB : Ozone Class 1 : I Seal type O-ring Seal type Seal with Stainless Steel reinforcement mm Cross sections 2-10 mm Height 5,6 7,8 mm Rubber Compound: EPDM Lopi 80 Ozone Class 1 : 80 IRHD I Seal type Cross sections application 2 : O-ring 2-10 mm II WB Width Technical Seals, membranes and flat rounds produced with EPDM Lopi 50, Lopi 60, Lopi 70 and Lopi 80 Product codes Cross Sections [mm] [mm] 9380-I 3, I 2, , I 3,8-8 65, I 3,8-8 89, I 4, , I 5, I 6, I 7, I, 9669-I, 9577-I, 9578-I, 9579-I, 9580-I,9581-I, 9582-I 9583-I, 9682-I, 9684-I 2,4 4, Profiles
3 page 3 of I, 9660-I, 9661-I, 9662-I 9663-I, 9664-I, 9713-I 2,3 4, I, 9757-I 9758-I 1,3 4, I 2-2, I 1 2, , I 1,8 3, , P 1,8 12, I 3,5 10, I 1,8 9, ,6 23, I 2,5 7, I I 2,5-4 20, I 6 22, I I 2 2, I I I 4 8, I 4 15, I 1,7 2,7 119, I 1,5 4, I 1,4 2,8 15, I 2,6-2,7 16, I 1, I 3,8-4 9, I 3 3, I 2 4, I 1,5 3, LC8 3 10,3 8, LC8 3 14, LC8 2,5 5, I I 4,7 9, I 2, I 2,7 16, I I I 4 6, I , P 7, I 3, I 3, I 3, I 1,9-5 5, I 0, I 1,2 3, I 1, I 1, I 1,8 2, I 2 6, I 2, I I I 0,5 0, P 1,2 1, P 1-4
4 page 4 of I 3, P 2,5 5, I 3,4 3,5 37, I 2,3 3,8 54, I 1,5 2,5 3, I 2,7-4 5, P 0,6 1,8 5, I 2 2,5 4, I 1,4-7 13, P 0,8 1,2 13, I 1, I I 2 5, I 1 11, I 1 5, I 1, I I 1 3,8 2, I , I 0,5 2, I 0,4 2, P 0,3 1, P 0,2 1,6 32, I 0,6 2,2 23, I 2,5 7, I 1,5-2 16, I 10,3-25 0,7 1, I 8, I 0,9 1,5 12,3 36, P 1-2 6,5 7, P 1,1 2, I 1, I 1 3,5 6,2
5 page 5 of I 4,8-8 20, I 3,3 3,5 10, I 9, I 1,5 5,5 12, I 15, I 1,2 3, I 5,7 5,9 7, P 1,1 3, I-SOSPESO 4,8 7,3 103, I-SOSPESO 5,5 8, P , I 4,8 5, I 9,1 12,7 68, I 3, I 3 4,5 7, I , I 1 3,6 1, I 8 15, I I I 2 3, I 1,3-4,5-1 Ozone resistance class according to BRL-2013: I For products with a high risk of attack by ozone, for instance in case of separately supplied products without sufficient packaging or in case of connections with preinstalled rubbers under strain; II For products for which a normal resistance to ozone is required; III For rubbers which are never (partly) exposed to the open air when they are in tension. Transport shall always take place in sealed packages. 2 application class according to BRL 2013 class: I Cold water supply at temperatures continuously up to 45 C and intermittently up to 95 C; II Hot water supply at temperatures intermittently up to 110 C, or water supply up to 110 C in serviceable piping systems; III Hot water circulation systems based on the classification class 2 in ISO 10508; IV District heating, secondary systems with hot water circulation between 75 C and 95 C. application class according to EN 681-1: WC As in BRL-2013 class I; WD As in BRL-2013 class II; WF As in BRL-2013 class II, for IIR-copolymer; WG As in BRL-2013 class I, oil resistance. Details of the products are included in the drawing list, which forms a part of the IQC schedule. Kiwa authenticates this list. A copy of this list can be obtained from the producer.
6 page 6 of 6 Fitness for contact with drinking water This product is approved on the basis of the requirements for hygienic aspects set in the "Regeling materialen en chemicaliën drink- en warm Gazette). These hygienic aspects are based on two main criteria. The product shall permanently comply with: The product recipe approved during the assessment procedure. This recipe is not to be changed without prior approval by Kiwa according to the Kiwa approval procedure for the hygienic aspects; Specific product requirements for the hygienic aspects. certificate. MARKING The following marks and indications must be provided on each product # and product packaging in a clear, legible and indelible way: the name of manufacturer or the deposited trade mark; Kiwa (or Kiwa word mark) and additionally the Kiwa watermark ; the nominal dimension or dimensions; the nominal hardness; the year of manufacturing and preferably the quarter; type of rubber applied by means of the letter codes of the nomenclature according to ISO 1629; the application class (I, II or III); lass is valid. # If the dimensions of the products are such that the indications applied to them may impair the product, the products may be marked per package in consultation with the manufacturer, the buyer and Kiwa. Products produced by cutting or die cutting out of sheets may be marked per package. APPLICATION AND USE RECOMMENDATIONS FOR CUSTOMERS Check at the time of delivery whether: the supplier has delivered in accordance with the agreement; the mark and the marking method are correct; the products show no visible defects as a result of transport etc. If you should reject a product on the basis of the above, please contact: LOPIGOM S.r.l. and, if necessary, Kiwa Nederland B.V.
Check valves, family E, type B
287/170315 Product certificate K6322/20 Issued 2017-08-01 Replaces K6322/19 Page 1 of 5 STATEMENT BY KIWA With this product certificate, issued in accordance with the Kiwa Regulations for Product Certification,
More informationSanitary tapware: mechanical mixers
Product certificate K55366/30 Issued 2018-09-01 Replaces K55366/29 Page 1 of 6 STATEMENT BY KIWA With this product certificate, issued in accordance with the Kiwa Regulations for Certification, Kiwa declares
More informationLeadax B.V. Covenant K93792/02. Leadax
561/170522 Covenant K93792/02 Uitgegeven 2017-12-01 Vervangt K93792/01 Pagina 1 of 5 VERKLARING VAN KIWA With this Covenant, issued in accordance with the Kiwa Regulations for Product Certification, Kiwa
More informationVilleroy & Boch AG. the Kiwa evaluation guideline BRL-KK621/06 Close coupled suites. EN 997: 2003 WC pans with integral trap.
130212 Product certificate K14654/06 Issued 2014-04-01 Replaces K14654/05 Page 1 of 5 STATEMENT BY KIWA With this product certificate, issued in accordance with the Kiwa Regulations for Product Certification,
More informationCPVC solvent cements for CPVC pipes and fittings
289/150609 Kiwa Covenant K93663/01 Issued 2017-01-01 Replaces Page 1 of 8 CPVC solvent cements for CPVC pipes and fittings STATEMENT BY KIWA With this Kiwa Covenant, issued in accordance with the Kiwa
More informationNumber K4126/06 Replaces K4126/05. Issued Dated Valid until Indefinite Page 1 of 6
KOMO product certificate Number K4126/06 eplaces K4126/05 Issued 2013-11-01 Dated 2013-10-01 Valid until Indefinite Page 1 of 6 DYKA B.V. STATEMENT BY KIWA This product certificate is issued on the basis
More informationDSPA DSPA B.V. Product Certificate K86591/07 UK. Non-Pressurized Condensed Aerosol Generators and Components K86591/06 UK
Product Certificate Issued 2018-07-11 Valid until 2019-07-10 Replaces Page 1 of 6 K86591/06 UK DSPA Non-Pressurized Condensed Aerosol Generators and Components STATEMENT BY KIWA With this product certificate,
More informationBRL-K14026/ Evaluation Guideline. for the Kiwa product certificate for Extractable shower hoses for sanitary tapware
2017-05-12 for the Kiwa product certificate for Extractable shower hoses for sanitary tapware Preface This evaluation guideline has been accepted by the Kiwa Board of Experts Watercycle (CWK), in which
More informationBRL-K14008/ Evaluation guideline. for the Kiwa product certificate for Cartridges to be used for sanitary tapware: Mechanical mixers
01-02-2012 Evaluation guideline for the Kiwa product certificate for Cartridges to be used for sanitary tapware: Mechanical mixers Preface This evaluation guideline has been accepted by the board of experts
More informationGASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment
KE 192 - A1 March 2012 GASTEC QA Evaluation Guideline KE 192 Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment Foreword and introduction These GASTEC QA Approval
More informationBRL-K629/03. Date Evaluation Guideline. for the Kiwa product certificate for. Backflow protection devices. Family E, Types A, B, C and D
BRL-K629/03 Date 01-02-2012 Evaluation Guideline for the Kiwa product certificate for Backflow protection devices Family E, Types A, B, C and D Preface Kiwa This (BRL) has been drawn up by Kiwa's Board
More informationBRL-K602. Datum Evaluation Guideline
Datum 2018-09-04 for the Kiwa product certificate for valves, control valves and non-return valves for drinking water transport and drinking water distribution systems Preface This evaluation guideline
More informationGASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012
KE 191 - A1 March 2012 GASTEC QA Evaluation Guideline KE 191 Amendment A1 Excess flow valves Foreword and introduction These GASTEC QA Approval requirements amendment have been accepted by the Board of
More informationBRL-K762. Datum Concept design. Evaluation Guideline. for the Kiwa product certificate for steel pipes for the transport of drinking water
BRL-K762 Datum 2017-07-03 Concept design for the Kiwa product certificate for steel pipes for the transport of drinking water 478/160822 Preface This evaluation guideline has been accepted by the Kiwa
More informationBRL-K774/ Evaluation guideline. for the Kiwa product certificate for Compression fittings to tighten with matching clamping device
01-02-2012 Evaluation guideline for the Kiwa product certificate for Compression fittings to tighten with matching clamping device Preface This evaluation guideline has been accepted by the board of experts
More informationKQ July 1, Evaluation Guideline
KQ 17602 July 1, 2011 Evaluation Guideline for the KiwaQuality product certificate for vulcanised rubber seals in plastic transport and storage systems for chemical liquids and gaseous fluids for industrial
More informationGASTEC QA. Approval Requirements 6
KE 6 March 2012 GASTEC QA Approval Requirements 6 for the GASTEC QA product certificate for Plumbing fittings with ends for capillar soldering and/or thread connections Foreword These GASTEC QA Approval
More informationEvaluation Guideline
BRL K14022 Date 2018-01-12 for the Kiwa product certificate for equipment for conditioning drinking water and/or hot tap water 478/160822 Preface This evaluation guideline has been accepted by the Kiwa
More informationGASTEC QA. Approval Requirements 31-1
KE 31-1 March 2012 GASTEC QA Approval Requirements 31-1 for the GASTEC QA product certificate for Sealing materials for metallic threaded joints in contact with 2nd and 3rd family gases and hot water Part
More informationGASTEC QA. Approval Requirements 31-2
KE 31-2 March 2012 GASTEC QA Approval Requirements 31-2 for the GASTEC QA product certificate for Sealing materials for metallic threaded joints in contact with 2nd and 3rd family gases and hot water Part
More informationGASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE)
KE 200 March 2012 GASTEC QA Approval Requirements 200 for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE) Foreword These GASTEC QA Approval requirements have
More informationBRL-K618/ Evaluation Guideline. for the Kiwa product certificate for Water meters
/08 2018-01-15 for the Kiwa product certificate for Water meters Preface This evaluation guideline has been accepted by the Kiwa Board of Experts Watercycle (CWK), in which all relevant parties in the
More informationEvaluation guideline. for the Kiwa product certificate for external Polyurethane Coatings on ductile iron pipes for underground installation
01-02-2012 Evaluation guideline for the Kiwa product certificate for external Polyurethane Coatings on ductile iron pipes for underground installation Preface This evaluation guideline has been accepted
More informationBRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems
5 August 2014 Certification of Alarm Communication Certification (ATS) Kiwa N.V. - 1-5 Augustus 2014 Preface This Evaluation Guideline (Certification Scheme) has been accepted by the Kiwa Board of Experts
More informationGASTEC QA. Approval Requirements 136
KE 136 January 2012 GASTEC QA Approval Requirements 136 for the GASTEC QA product certificate for Polyethylene (PE) valves for plastic piping systems for the supply of gaseous fuels Foreword These GASTEC
More informationBRL-K Evaluation Guideline. for the Kiwa product certificate for products used for treatment and / or production of drinking water
25-10-2016 for the Kiwa product certificate for products used for treatment and / or production of drinking water Preface This evaluation guideline has been accepted by the Kiwa Board of Experts CWK, in
More informationBRL-K Evaluation Guideline
2016-10-06 for the Kiwa technical approval with product certificate for plastics piping systems for water supply with or without pressure Glass-reinforced thermosetting plastics (GRP) based on unsaturated
More informationGASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012
KE 15 January 2012 GASTEC QA Approval Requirements 15 for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas Foreword These GASTEC QA Approval requirements have been
More informationBRL-K656/ Evaluation guideline. for the Kiwa product certificate for heat exchangers intended for the indirect heating of drinking water
2012-02-01 Evaluation guideline for the Kiwa product certificate for heat exchangers intended for the indirect heating of drinking water Preface This evaluation guideline has been accepted by the board
More informationEvaluation Guideline. for the Kiwa product certificate for plastics piping systems of polyethylene for the transport of drinking water and raw water
BRL-K17105 2017-10-03 for the Kiwa product certificate for plastics piping systems of polyethylene for the transport of drinking water and raw water Preface Kiwa This evaluation guideline has been prepared
More informationGASTEC QA. Approval Requirements 201. Amendment A1. for the GASTEC QA product certificate for Gas service lines to residences and buildings
KE 201-A1 June 2014 GASTEC QA Approval Requirements 201 Amendment A1 for the GASTEC QA product certificate for Gas service lines to residences and buildings Foreword and introduction These GASTEC QA Approval
More informationGASTEC QA. Approval Requirements 69-1
KE 69-1 May 2014 GASTEC QA Approval Requirements 69-1 for the GASTEC QA product certificate for Manually operated ball valves and closed bottom taper plug valves for gas installations for buildings Foreword
More informationBRL-K17401 Comments before.. Replaces BRL-K17401 d.d. 16 April Evaluation guideline
Comments before.. Replaces d.d. 16 April 2004 Evaluation guideline For the Kiwa (technical approval-with-) product certificate for District heating: flexible piping systems with plastic medium pipe for
More informationBRL-K619/ Evaluation Guideline. for the Kiwa product certificate for WC-pans
2015-11-10 for the Kiwa product certificate for WC-pans V20141215 Preface This evaluation guideline has been accepted by the Kiwa Board of Experts Watercycle (CWK), in which all relevant parties in the
More informationViega Technology GmbH & Co. KG
KIWA Covenant K90465/02 Issued: 01-01-2017 STATEMENT BY KIWA This Covenant of Kiwa ascertains that the: Raxinox multilayer piping system of stainless steel pipes with plastic covering and stainless steel/plastic
More informationEvaluation Guideline. for the KOMO (technical approval-with-) product certificate for
6 January 2014 for the KOMO (technical approval-with-) product certificate for Pre-insulated flexible plastics piping systems for warm water distribution outside buildings Validated by the Board of Experts
More informationGASTEC QA. Approval Requirements 7. for the GASTEC QA product certificate for bendable gas meter connection pipes. KE 7 March 2012
KE 7 March 2012 GASTEC QA Approval Requirements 7 for the GASTEC QA product certificate for bendable gas meter connection pipes Foreword These GASTEC QA Approval requirements have been accepted by the
More informationEvaluation Guideline. regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances
1st February 2011 regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances Foreword This has been adopted by the Kiwa Board of Experts of Energy
More informationKiwa Nederland B.V. Unit Appliances & Controls, Unit Automotive, Unit Gasdistribution Materials and Unit ExVision
of Kiwa Nederland B.V. Sir Winston Churchill-laan 273 2288 EA Rijswijk The Netherlands Location(s) where activities are performed under accreditation Head Office Location Abbreviation/ location code Main
More informationISO INTERNATIONAL STANDARD. Fluid power systems O-rings Part 5: Suitability of elastomeric materials for industrial applications
INTERNATIONAL STANDARD ISO 3601-5 First edition 2002-07-01 Fluid power systems O-rings Part 5: Suitability of elastomeric materials for industrial applications Transmissions hydrauliques et pneumatiques
More informationKiwa Regulations for Certification in accordance with the CPR
1 May 2014 Kiwa Regulations for Certification in accordance with the CPR EC Regulation No. 305/2011 (CPR) 1 May 2014 Kiwa Regulations for Certification in accordance with the CPR EC Regulation No. 305/2011
More informationCE MARKING OF WOOD-BASED PANELS
28 Market Place Grantham Lincolnshire NG31 6LR Tel: 00 44 (0) 1476 563707 Fax: 0044 (0) 1476 579314 e-mail: wpif.panelboards@virgin.net WOOD PANEL INDUSTRIES FEDERATION CE MARKING OF WOOD-BASED PANELS
More informationSCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF PORTABLE FIRE EXTINGUISHER- PERFORMANCE AND CONSTRUCTION AS PER IS 15683: 2006
SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF PORTABLE FIRE EXTINGUISHER- PERFORMANCE AND CONSTRUCTION AS PER IS 15683: 2006 1. LABORATORY 1.1 A Laboratory shall be maintained which shall be suitably
More informationCoatings for protection of FRP structures with heavy rain erosion loads
CLASS PROGRAMME Type approval DNVGL-CP-0424 Edition May 2016 Coatings for protection of FRP structures with heavy rain erosion loads The content of this service document is the subject of intellectual
More informationRubber seals for industrial applications
12 May 2011 Partner for progress Rubber seals for industrial applications Hans Naus, Senior Consultant Rubber Outline Introduction Certification: why, what? Kiwa certification schemes for seals New certification
More information0014-L-16/1 2 March Test report. EPDM Quickgoot system
0014-L-16/1 2 March 2016 Test report EPDM Quickgoot system 0014-L-16/1 2 March 2016 Test report EPDM Quickgoot system 2016 Kiwa N.V. All rights reserved. No part of this report may be reproduced, stored
More informationfixed dry aerosol fire extinguishing components FirePro Systems Ltd.
product certificate Issued 2013-01-11 Valid untill 2013-11-19 Replaces K21477/11 Page 1 of 22 FirePro fixed dry aerosol fire extinguishing components STATEMENT BY KIWA With this product certificate, issued
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationSHOP PRIMERS FOR CORROSION PROTECTION OF STEEL PLATES AND SECTIONS
STANDARD FOR CERTIFICATION No. 2.9 SHOP PRIMERS FOR CORROSION PROTECTION OF STEEL PLATES AND SECTIONS OCTOBER 2009 Veritasveien 1, NO-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD
More informationRULEBOOK ON ELECTROMAGNETIC COMPATIBILITY
RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY ("Official Gazette of RS, issue No. 13/2010) I INTRODUCTION Scope Article 1 This Rulebook stipulates the essential requirements that shall be met with regard to
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Sponsor Prepared by P.O. Box 70 NL-5750 AB DEURNE Efectis Nederland BV Lange Kleiweg 5 P.O. Box 1090 NL-2280 CB
More informationKiwa Nederland B.V. Unit Appliances & Controls, Unit Automotive, Unit Gasdistribution Materials and Unit ExVision
nnex to declaration accreditation (scope accreditation) Unit ppliances & Controls, Unit utomotive, Unit Gasdistribution Materials and Unit This annex is valid from: 15-11-2017 to 01-10-2018 Replaces annex
More informationISO 1403 INTERNATIONAL STANDARD. Rubber hoses, textile-reinforced, for general-purpose water applications Specification
INTERNATIONAL STANDARD ISO 1403 Fourth edition 2005-02-15 Rubber hoses, textile-reinforced, for general-purpose water applications Specification Tuyaux en caoutchouc à armature textile d'usage général
More informationBUREAU OF INDIAN STANDARDS ( CENTRAL MARKS DEPARTMENT-III ) Our Ref: CMD-III/16:
BUREAU OF INDIAN STANDARDS ( CENTRAL MARKS DEPARTMENT-III ) Our Ref: CMD-III/16:2878 03-12-2007 Subject: Implementation of Amendment No 4 August 2007 to IS 2878:2004 For Fire Extinguishers, Carbon Dioxide
More informationFire Protection Scover
November 2nd, 2011 2e version Fire Protection Scover Testing Fire Protection of a small storage facility for vehicles for handicapped transport based on certification scheme BRL-K23003. Fire Protection
More informationGLASS FIBRE REINFORCEMENTS
STANDARD FOR CERTIFICATION No. 2.9 GLASS FIBRE REINFORCEMENTS OCTOBER 2009 Veritasveien 1, NO-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD (DNV) is an autonomous and independent
More informationAIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND SINGLE-SPLIT
SAUDI ARABIAN STANDARD SASO 2663/2017 والجودة الھيئة السعودية للمواصفات والمقاييس Saudi Standards, Metrology and Quality Org (SASO) SASO 2663:2017 (Draft) AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61518 First edition 2000-11 Mating dimensions between differential pressure (type) measuring instruments and flanged-on shut-off devices up to 413 bar (41,3 MPa) Dimensions des
More informationISO INTERNATIONAL STANDARD. Fire-fighting hoses Rubber and plastics suction hoses and hose assemblies
INTERNATIONAL STANDARD ISO 14557 First edition 2002-12-01 Fire-fighting hoses Rubber and plastics suction hoses and hose assemblies Tuyaux de lutte contre l incendie Tuyaux d aspiration et flexibles en
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationdesign BRL-K Evaluation Guideline
design BRL-K17605 2016-06-09 for the Kiwa technical approval with product certificate for plastics piping systems for water supply with or without pressure Glass-reinforced thermosetting plastics (GRP)
More informationThis annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation
nnex to declaration accreditation (scope accreditation) egistration number: L 015 This annex is valid from: 01-08-2018 to 01-09-2020 eplaces annex dated: 21-03-2018 Location(s) where activities are performed
More informationUNECE standard FFV-04 (CODEX STAN )
C0MPARISON STANDARD OF ASPARAGUS CODEX STANDARD FOR ASPARAGUS Concerning the marketing and commercial quality control asparagus I. Definition of produce This standard applies to shoots of asparagus of
More informationWelcome to the world of EPDM roofing systems
Welcome to the world of EPDM roofing systems WWW.HERTALAN.CO.UK 2 3 50 YEARS PRACTICAL EXPERIENCE ON THE ROOF PLEASED TO MEET YOU ROOFING SYSTEMS CARLISLE Construction Materials has been producing EPDM
More informationDate of Start and downloading the tender 12 sep 2018
INDRAPRASTHA INSTITUTE OF INFORMATION TECHNOLOGY-DELHI (IIIT-DELHI) Okhla Industrial Estate, Phase III New Delhi 110020 (Tel No 011-26907400, Website: www.iiitd.ac.in) Notice Inviting Tender for Non Comprehensive
More informationRecord of Amendments. Version Date Amendment Section/page affected
Industry support for effective compliance BTHA Guidance - The Low Voltage Directive (LVD) Directive 2014/35/EU On the harmonisation of the laws of the Member States relating to the making available on
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationMembership Application
REGISTERED BUSINESS NAME TRADING NAME (if different) BUSINESS ADDRESS POSTAL ADDRESS (if different) REGISTERED BUSINESS ADDRESS Same as physical address ABN YEAR BUSINESS REGISTERED (certificate to be
More informationSELF PRESERVATION SOCIETY By Jim Creak
SELF PRESERVATION SOCIETY By Editor of the Means of Escape Magazine and Chairman of The Health & Safety Signs Association. w w w. m e a n s - of- e s c a p e. c o m Agenda Regulatory Reform Fire Safety
More informationQuality Control Acceptance Sampling Systems
Quality Control Acceptance Sampling Systems Lot-by-Lot Acceptance Sampling Plans for Attributes Devised in 1942 at Bell Labs Later became MIL-STD-105E ISO-2859 ANSI/ASQ Z1.4 Wording & terminology changes
More informationBUREAU OF INDIAN STANDARDS CENTRAL MARKS DEPARTMENT-III
BUREAU OF INDIAN STANDARDS CENTRAL MARKS DEPARTMENT-III Our Ref: CMD-III/16:15683 02/04/2013 Subject: Implementation of Modified Scheme of Testing and Inspection Doc: STI/15683/2, as per :2006 for the
More informationUN/ECE STANDARD H-2 concerning the marketing and commercial quality control of
STANDARD FOR CUT FOLIAGE (H-2) REVISED 1994 UN/ECE STANDARD H-2 concerning the marketing and commercial quality control of CUT FOLIAGE moving in international trade between and to UN/ECE member countries
More informationWet alarm valve stations
VdS Guidelines for water extinguishing systems VdS 2100-01en Requirements and test methods VdS 2100-01en : 2011-05 (02) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
More informationKiwa in 2016 Trust Quality Progress
We create trust Kiwa in 2016 Trust Quality Progress Kiwa in brief Kiwa Annual Report 2016 We are Kiwa, a global leader in Testing, Inspection and Certification (TIC). With our certification, inspection,
More informationTEST REPORT No
Istituto Giordano S.p.A. Via Rossini, 2-47814 Bellaria-Igea Marina (RN) - Italia Tel. +39 0541 343030 - Fax +39 0541 345540 istitutogiordano@giordano.it - www.giordano.it PEC: ist-giordano@legalmail.it
More informationYour Key to achieving C.E Marking Compliance
Your Key to achieving C.E Marking Compliance As of the 1 st July 2013 The Construction Products Regulation 2011 contains clauses relating to C E marking of products. This will therefore mean that a CE
More informationTechnical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme:
Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme: Solar products and components Accreditation Kiwa Italia S.p.A. Via Treviso 32/34 31020 San Vendemiano (TV) Italia Tel: +39
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification
More informationConformity assessment procedures for the Alarm Components Scheme
Conformity assessment procedures for the Alarm RD_070, Issue 20 This guide describes the conformity assessment procedures for Alarm Components. This Alarm certifies that Alarm Components comply with technical
More informationHygienic Instruction. EHEDG, Installation and Cleaning Instructions. VEGAVIB VB61, VB63 Hygienic process fittings. Document ID: 35483
Hygienic Instruction EHEDG, Installation and Cleaning Instructions VEGAVIB VB61, VB63 Hygienic process fittings Document ID: 35483 Contents Contents 1 About this document... 3 1.1 Function... 3 1.2 Scope...
More informationAustralian/New Zealand Standard
AS/NZS 3809:1998 Australian/New Zealand Standard Safes and strongrooms AS/NZS 3809:1998 This Joint Australian/New Zealand Standard was prepared by Joint Technical Committee MS/58, Prefabricated Safes and
More informationPART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...
CONTENTS Schedule of amendments for this part of the scheme document Page 1 of 14 3-O Introduction...3 3-O.1 Scope of Maintenance and Supervision...3 3-O.2 Certification conditions...5 3-O.3 LPS 1233 Service
More informationGlass fibre rovings - Non-metallic materials
CLASS PROGRAMME Type approval DNVGL-CP-0082 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationEFFISUS BRAZE MEMBRANE
Effisus Braze Membrane EFFISUS BRAZE MEMBRANE Elastomer sheets for facade sealing from Ethylen-Propylen-Dien-Terpolymer (EPDM), homogeneous, cured without fleece-backing. Elastomer sheets for facade waterproofing.
More informationdhf General Information Automated Gates Guidance for enforcement bodies
Automated Gates Guidance for enforcement bodies www.dhfonline.org.uk Contents About dhf 1 Applicable legislation & standards 2 Annex A 4 Useful links 5 About dhf dhf represents the key manufacturers and
More informationMembership Application
REGISTERED BUSINESS NAME TRADING NAME (if different) BUSINESS ADDRESS POSTAL ADDRESS (if different) REGISTERED BUSINESS ADDRESS Same as physical address ABN YEAR BUSINESS REGISTERED (certificate to be
More informationFOR ENGCON STONE AND SCRAP HANDLING GRAB SK05ST-SK30ST THE WIDEST RANGE ON THE MARKET
Instruction manual Stone and scrap handling grab SK05ST-SK30ST English FOR ENGCON STONE AND SCRAP HANDLING GRAB SK05ST-SK30ST THE WIDEST RANGE ON THE MARKET Increase your excavator s efficiency and precision
More informationCODEX STANDARD FOR ASPARAGUS CODEX STAN
CODEX STAN 225-2001 Page 1 of 6 1. DEFINITION OF PRODUCE CODEX STANDARD FOR ASPARAGUS CODEX STAN 225-2001 This Standard applies to shoots of commercial varieties of asparagus grown from Asparagus officinalis
More informationAudible warning devices for external alarm
VdS SCHADENVERHÜTUNG VdS Publisher: Gesamtverband der Deutschen Versicherungswirtschaft e.v. (GDV) Büro Schadenverhütung Publishing house: VdS Schadenverhütung Rules for Intruder Alarm Systems Audible
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-626-23127-9 SOUTH AFRICAN NATIONAL STANDARD Portable refillable fire extinguishers Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001 Tel: +27 12
More informationScheme for Recognition of Heritage Irrigation Structures (HIS)
Scheme for Recognition of Heritage Irrigation Structures (HIS) Scheme for Recognition of Heritage Irrigation Structures (HIS) 1. Background 1.1 At the 63 rd meeting of International Executive Council (IEC)
More informationProduct manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands
Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein 15 3214 VP Zuidland Netherlands T. +31(0)181 452120 http/www.indexelektro.nl email info@indexelektro.nl Purpose of these instructions
More informationNotification of a Body pursuant to article 10 of the Construction Products Directive 89/106/EEC
Notification of a Body pursuant to article 10 of the Construction Products Directive 89/106/EEC From : Ministry of VROM - Cluster Bouwkwaliteit Rijnstraat 8 P.O. Box 30941 2500 GX Den Haag Netherlands
More informationTrade Practices (Consumer Product Safety Standard Corded Internal Window Coverings) Regulations
Trade Practices (Consumer Product Safety Standard Corded Internal Window Coverings) Regulations 2010 1 Select Legislative Instrument 2010 No. 212 I, QUENTIN BRYCE, Governor-General of the Commonwealth
More informationISO INTERNATIONAL STANDARD. Fire-resistance tests Elements of building construction Part 1: General requirements
INTERNATIONAL STANDARD ISO 834-1 First edition 1999-09-15 Fire-resistance tests Elements of building construction Part 1: General requirements Essai de résistance au feu Éléments de construction Partie
More informationMultipoint Technical Data
Multipoint Technical Data Multipoint 10 / 15 Specification DIMENSIONS AND PERFORMANCE Model Multipoint 10 vertical Multipoint 15 vertical Multipoint 10 4.5kW vertical Multipoint 15 4.5kW vertical A - Height
More informationCLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009
P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com CLASSIFICATION CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Bucknalls Lane Garston Watford Hertfordshire WD25 9BA Contact: Alvaro Enquita-Gonzalez Tel: +44 (0)1923-665350 Fax: +44 (0)1923-665452 E-Mail:
More informationReview Fire Test Report
Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Review Fire Test Report Determination of
More information