1 KOMO product certificate Number K4126/06 eplaces K4126/05 Issued Dated Valid until Indefinite Page 1 of 6 DYKA B.V. STATEMENT BY KIWA This product certificate is issued on the basis of B "Plastic piping systems for nonpressure sewerage inside buildings" issued on 24 May 2012 by Kiwa, in accordance with the Kiwa egulations for Product Certification. Kiwa declares that legitimate confidence exists that the by the producer manufactured PVC Fittings sewerage comply with the technical specifications as laid down in this product certificate, provided that PVC Fittings sewerage have been marked with the KOMO -mark in the manner as indicated in this product certificate. Bouke Meekma Kiwa Kiwa Nederland B.V. Sir Winston Churchilllaan 273 Postbus AB IJSWIJK The Netherlands Tel Fax info@kiwa.nl The certificate is listed in the overview on the website of Stichting KOMO: Advice: consult in order to ensure that this certificate is still valid. Holder of Certificate DYKA B.V. Produktieweg J STEENWIJK Postbus AA STEENWIJK T F I Evaluated is: quality system product Periodic inspection

2 PODUCT SPECIFICATION Fittings of PVC intended for non-pressure plastics piping systems sewerage outside buildings according to B The products mentioned in the tables below are part of this certificate. Table 1 odding Pieces, Class 41 Screw Diameter in mm Table 2 - Bends, Class ' ' 90 * 90 (Elbow) * 90 can be zijn Table 3 - Double sockets, Class 41 (incl. slip couplers) M M M = rubber sealing joint = adhesive-/ sealing joint = socket-socket Page 2 of 6

3 Table 4 Single tees, Class /32 40/32 40/40 50/32 50/40 50/50 50/50 Y-piece 75/40 75/50 75/75 90/90 110/40 110/50 M M 110/75 M M * 110/110/75/75 ** 110/90 110/ /50 125/75 125/ / / / / / / / /200 * Also as short version ** crossing piece Table 5 - educers, Class 41 educer piece educer ring C E C E 40/32 40/40 50/32 50/40 50/50 75/40 75/50 75/75 90/40 90/50 90/75 90/90 110/40 110/40/40 110/50 110/50/50 110/75 110/90 110/ /40 125/50 Page 3 of 6

4 Continuation Table 5 educers, Class 41 educer piece educer ring C E C E 125/75 125/90 125/ / / / /160 * Also as short version ** crossing piece M de C E = rubber sealing ring joint = adhesive-/ sealing joint = socket-socket = centric = eccentric Table 6 Flow tees, Class /40 50/40 50/50 75/40 75/50 75/75 90/40 90/50 90/75 90/90 110/40 110/50 110/75 110/90 110/ / / /160 Table 7 - Double sockets, Class 34 (incl. Slip Couplers) M Page 4 of 6

5 Continuation Table 7 - Double sockets, Class 34 (incl. Slip Couplers) Table 8 - Bends, Class ' ' Table 9 odding pieces, Class 34 Screw 110 * = as well with flat- as flow cover = rubber sealing ring joint = socket- socket Table 10 Single tees, Class / /110 cross piece 125/ / / / / / / /160 Table 11 - Expansion piece, Class 34 d educer C E 125/ / / / /160 Page 5 of 6

6 = rubber sealing ring joint = socket- socket MAKING The products are marked with the KOMO -mark. This marking is implemented in the following way: KOMO word mark; manufacturers name of trademark; material indication: PVC ; class; product standard: B 52100; fitting angle (if applicable); nominal diameter based on the outer middle line; production period. ocation of the marking: on every fitting. ECOENDATIONS FO CUSTOMES Check at the time of delivery whether: the supplier has delivered in accordance with the agreement; the mark and the marking method are correct; the products show no visible defects as a result of transport etc. If you should reject a product on the basis of the above, please contact: DYKA B.V. and, if necessary, Kiwa Nederland B.V. Consult the supplier s processing guidelines for the proper storage and transport methods. CONSTUCTION PODUCTS EGUATIONS If a construction product is subject to a European harmonised technical specification, the statements in this KOMO product certificate must not be used as a replacement for the CE marking on such construction product and/or for the associated obligatory Declaration of Performance. Page 6 of 6

Villeroy & Boch AG. the Kiwa evaluation guideline BRL-KK621/06 Close coupled suites. EN 997: 2003 WC pans with integral trap.

Villeroy & Boch AG. the Kiwa evaluation guideline BRL-KK621/06 Close coupled suites. EN 997: 2003 WC pans with integral trap. 130212 Product certificate K14654/06 Issued 2014-04-01 Replaces K14654/05 Page 1 of 5 STATEMENT BY KIWA With this product certificate, issued in accordance with the Kiwa Regulations for Product Certification,

More information

Vulcanised rubber products for cold and hot drinking water applications

Vulcanised rubber products for cold and hot drinking water applications Product certificate K43802/06 Issued 2017-11-01 Replaces K43802/05 Page 1 of 6 Vulcanised rubber products for cold and hot drinking water applications STATEMENT BY KIWA With this product certificate, issued

More information

CPVC solvent cements for CPVC pipes and fittings

CPVC solvent cements for CPVC pipes and fittings 289/150609 Kiwa Covenant K93663/01 Issued 2017-01-01 Replaces Page 1 of 8 CPVC solvent cements for CPVC pipes and fittings STATEMENT BY KIWA With this Kiwa Covenant, issued in accordance with the Kiwa

More information

Check valves, family E, type B

Check valves, family E, type B 287/170315 Product certificate K6322/20 Issued 2017-08-01 Replaces K6322/19 Page 1 of 5 STATEMENT BY KIWA With this product certificate, issued in accordance with the Kiwa Regulations for Product Certification,

More information

Leadax B.V. Covenant K93792/02. Leadax

Leadax B.V. Covenant K93792/02. Leadax 561/170522 Covenant K93792/02 Uitgegeven 2017-12-01 Vervangt K93792/01 Pagina 1 of 5 VERKLARING VAN KIWA With this Covenant, issued in accordance with the Kiwa Regulations for Product Certification, Kiwa

More information

Sanitary tapware: mechanical mixers

Sanitary tapware: mechanical mixers Product certificate K55366/30 Issued 2018-09-01 Replaces K55366/29 Page 1 of 6 STATEMENT BY KIWA With this product certificate, issued in accordance with the Kiwa Regulations for Certification, Kiwa declares

More information

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012 KE 191 - A1 March 2012 GASTEC QA Evaluation Guideline KE 191 Amendment A1 Excess flow valves Foreword and introduction These GASTEC QA Approval requirements amendment have been accepted by the Board of

More information

BRL-K629/03. Date Evaluation Guideline. for the Kiwa product certificate for. Backflow protection devices. Family E, Types A, B, C and D

BRL-K629/03. Date Evaluation Guideline. for the Kiwa product certificate for. Backflow protection devices. Family E, Types A, B, C and D BRL-K629/03 Date 01-02-2012 Evaluation Guideline for the Kiwa product certificate for Backflow protection devices Family E, Types A, B, C and D Preface Kiwa This (BRL) has been drawn up by Kiwa's Board

More information

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment KE 192 - A1 March 2012 GASTEC QA Evaluation Guideline KE 192 Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment Foreword and introduction These GASTEC QA Approval

More information

GASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE)

GASTEC QA. Approval Requirements 200. for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE) KE 200 March 2012 GASTEC QA Approval Requirements 200 for the GASTEC QA product certificate for fusion fittings and saddles made from Polyethylene (PE) Foreword These GASTEC QA Approval requirements have

More information

DSPA DSPA B.V. Product Certificate K86591/07 UK. Non-Pressurized Condensed Aerosol Generators and Components K86591/06 UK

DSPA DSPA B.V. Product Certificate K86591/07 UK. Non-Pressurized Condensed Aerosol Generators and Components K86591/06 UK Product Certificate Issued 2018-07-11 Valid until 2019-07-10 Replaces Page 1 of 6 K86591/06 UK DSPA Non-Pressurized Condensed Aerosol Generators and Components STATEMENT BY KIWA With this product certificate,

More information

GASTEC QA. Approval Requirements 136

GASTEC QA. Approval Requirements 136 KE 136 January 2012 GASTEC QA Approval Requirements 136 for the GASTEC QA product certificate for Polyethylene (PE) valves for plastic piping systems for the supply of gaseous fuels Foreword These GASTEC

More information

GASTEC QA. Approval Requirements 6

GASTEC QA. Approval Requirements 6 KE 6 March 2012 GASTEC QA Approval Requirements 6 for the GASTEC QA product certificate for Plumbing fittings with ends for capillar soldering and/or thread connections Foreword These GASTEC QA Approval

More information

GASTEC QA. Approval Requirements 69-1

GASTEC QA. Approval Requirements 69-1 KE 69-1 May 2014 GASTEC QA Approval Requirements 69-1 for the GASTEC QA product certificate for Manually operated ball valves and closed bottom taper plug valves for gas installations for buildings Foreword

More information

BRL-K774/ Evaluation guideline. for the Kiwa product certificate for Compression fittings to tighten with matching clamping device

BRL-K774/ Evaluation guideline. for the Kiwa product certificate for Compression fittings to tighten with matching clamping device 01-02-2012 Evaluation guideline for the Kiwa product certificate for Compression fittings to tighten with matching clamping device Preface This evaluation guideline has been accepted by the board of experts

More information

GASTEC QA. Approval Requirements 31-1

GASTEC QA. Approval Requirements 31-1 KE 31-1 March 2012 GASTEC QA Approval Requirements 31-1 for the GASTEC QA product certificate for Sealing materials for metallic threaded joints in contact with 2nd and 3rd family gases and hot water Part

More information

GASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012

GASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012 KE 15 January 2012 GASTEC QA Approval Requirements 15 for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas Foreword These GASTEC QA Approval requirements have been

More information

BRL-K602. Datum Evaluation Guideline

BRL-K602. Datum Evaluation Guideline Datum 2018-09-04 for the Kiwa product certificate for valves, control valves and non-return valves for drinking water transport and drinking water distribution systems Preface This evaluation guideline

More information

BRL-K14008/ Evaluation guideline. for the Kiwa product certificate for Cartridges to be used for sanitary tapware: Mechanical mixers

BRL-K14008/ Evaluation guideline. for the Kiwa product certificate for Cartridges to be used for sanitary tapware: Mechanical mixers 01-02-2012 Evaluation guideline for the Kiwa product certificate for Cartridges to be used for sanitary tapware: Mechanical mixers Preface This evaluation guideline has been accepted by the board of experts

More information

GASTEC QA. Approval Requirements 31-2

GASTEC QA. Approval Requirements 31-2 KE 31-2 March 2012 GASTEC QA Approval Requirements 31-2 for the GASTEC QA product certificate for Sealing materials for metallic threaded joints in contact with 2nd and 3rd family gases and hot water Part

More information

BRL-K14026/ Evaluation Guideline. for the Kiwa product certificate for Extractable shower hoses for sanitary tapware

BRL-K14026/ Evaluation Guideline. for the Kiwa product certificate for Extractable shower hoses for sanitary tapware 2017-05-12 for the Kiwa product certificate for Extractable shower hoses for sanitary tapware Preface This evaluation guideline has been accepted by the Kiwa Board of Experts Watercycle (CWK), in which

More information

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems

BRL-K21030/02 5 August Certification of Alarm Communication. Certification Alarm Transmission Systems (ATS) Alarm Transmission Systems 5 August 2014 Certification of Alarm Communication Certification (ATS) Kiwa N.V. - 1-5 Augustus 2014 Preface This Evaluation Guideline (Certification Scheme) has been accepted by the Kiwa Board of Experts

More information

Kiwa Regulations for Certification in accordance with the CPR

Kiwa Regulations for Certification in accordance with the CPR 1 May 2014 Kiwa Regulations for Certification in accordance with the CPR EC Regulation No. 305/2011 (CPR) 1 May 2014 Kiwa Regulations for Certification in accordance with the CPR EC Regulation No. 305/2011

More information

Evaluation guideline. for the Kiwa product certificate for external Polyurethane Coatings on ductile iron pipes for underground installation

Evaluation guideline. for the Kiwa product certificate for external Polyurethane Coatings on ductile iron pipes for underground installation 01-02-2012 Evaluation guideline for the Kiwa product certificate for external Polyurethane Coatings on ductile iron pipes for underground installation Preface This evaluation guideline has been accepted

More information

GASTEC QA. Approval Requirements 201. Amendment A1. for the GASTEC QA product certificate for Gas service lines to residences and buildings

GASTEC QA. Approval Requirements 201. Amendment A1. for the GASTEC QA product certificate for Gas service lines to residences and buildings KE 201-A1 June 2014 GASTEC QA Approval Requirements 201 Amendment A1 for the GASTEC QA product certificate for Gas service lines to residences and buildings Foreword and introduction These GASTEC QA Approval

More information

GASTEC QA. Approval Requirements 7. for the GASTEC QA product certificate for bendable gas meter connection pipes. KE 7 March 2012

GASTEC QA. Approval Requirements 7. for the GASTEC QA product certificate for bendable gas meter connection pipes. KE 7 March 2012 KE 7 March 2012 GASTEC QA Approval Requirements 7 for the GASTEC QA product certificate for bendable gas meter connection pipes Foreword These GASTEC QA Approval requirements have been accepted by the

More information

Evaluation Guideline. for the KOMO (technical approval-with-) product certificate for

Evaluation Guideline. for the KOMO (technical approval-with-) product certificate for 6 January 2014 for the KOMO (technical approval-with-) product certificate for Pre-insulated flexible plastics piping systems for warm water distribution outside buildings Validated by the Board of Experts

More information

BRL-K Evaluation Guideline

BRL-K Evaluation Guideline 2016-10-06 for the Kiwa technical approval with product certificate for plastics piping systems for water supply with or without pressure Glass-reinforced thermosetting plastics (GRP) based on unsaturated

More information

BRL-K656/ Evaluation guideline. for the Kiwa product certificate for heat exchangers intended for the indirect heating of drinking water

BRL-K656/ Evaluation guideline. for the Kiwa product certificate for heat exchangers intended for the indirect heating of drinking water 2012-02-01 Evaluation guideline for the Kiwa product certificate for heat exchangers intended for the indirect heating of drinking water Preface This evaluation guideline has been accepted by the board

More information

BRL-K762. Datum Concept design. Evaluation Guideline. for the Kiwa product certificate for steel pipes for the transport of drinking water

BRL-K762. Datum Concept design. Evaluation Guideline. for the Kiwa product certificate for steel pipes for the transport of drinking water BRL-K762 Datum 2017-07-03 Concept design for the Kiwa product certificate for steel pipes for the transport of drinking water 478/160822 Preface This evaluation guideline has been accepted by the Kiwa

More information

BRL-K618/ Evaluation Guideline. for the Kiwa product certificate for Water meters

BRL-K618/ Evaluation Guideline. for the Kiwa product certificate for Water meters /08 2018-01-15 for the Kiwa product certificate for Water meters Preface This evaluation guideline has been accepted by the Kiwa Board of Experts Watercycle (CWK), in which all relevant parties in the

More information

Evaluation Guideline

Evaluation Guideline BRL K14022 Date 2018-01-12 for the Kiwa product certificate for equipment for conditioning drinking water and/or hot tap water 478/160822 Preface This evaluation guideline has been accepted by the Kiwa

More information

Evaluation Guideline. regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances

Evaluation Guideline. regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances 1st February 2011 regarding the Product Certificate GASKEUR Label HR (High Efficiency, Heating):2010 for Central Heating Appliances Foreword This has been adopted by the Kiwa Board of Experts of Energy

More information

0014-L-16/1 2 March Test report. EPDM Quickgoot system

0014-L-16/1 2 March Test report. EPDM Quickgoot system 0014-L-16/1 2 March 2016 Test report EPDM Quickgoot system 0014-L-16/1 2 March 2016 Test report EPDM Quickgoot system 2016 Kiwa N.V. All rights reserved. No part of this report may be reproduced, stored

More information

KQ July 1, Evaluation Guideline

KQ July 1, Evaluation Guideline KQ 17602 July 1, 2011 Evaluation Guideline for the KiwaQuality product certificate for vulcanised rubber seals in plastic transport and storage systems for chemical liquids and gaseous fluids for industrial

More information

CE TYPE EXAMINATION CERTIFICATE

CE TYPE EXAMINATION CERTIFICATE In application of the directive 89/686/EEG of 21 December 1989 concerning the harmonisation of the Member States legislation relative to personal protective equipment, Centexbel Notified body 0493 authorised

More information

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

PowerVent. Installation manual (GB) English. Store this document in a safe place UK PowerVent Installation manual (GB) Store this document in a safe place 959.034.03.UK GB Contents Blz Foreword 3 1. Introduction 3 2. CE declaration 4 3. SAFETY 4 3.1 General 4 3.2 Regulations 4 3.3 Precautions

More information

Evaluation Guideline. for the Kiwa product certificate for plastics piping systems of polyethylene for the transport of drinking water and raw water

Evaluation Guideline. for the Kiwa product certificate for plastics piping systems of polyethylene for the transport of drinking water and raw water BRL-K17105 2017-10-03 for the Kiwa product certificate for plastics piping systems of polyethylene for the transport of drinking water and raw water Preface Kiwa This evaluation guideline has been prepared

More information

fixed dry aerosol fire extinguishing components FirePro Systems Ltd.

fixed dry aerosol fire extinguishing components FirePro Systems Ltd. product certificate Issued 2013-01-11 Valid untill 2013-11-19 Replaces K21477/11 Page 1 of 22 FirePro fixed dry aerosol fire extinguishing components STATEMENT BY KIWA With this product certificate, issued

More information

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

PowerVent. Installation manual (GB) English. Store this document in a safe place UK PowerVent Installation manual (GB) Store this document in a safe place 959.078.00.UK GB Contents page Foreword 3 1. Introduction 3 2. CE declaration 4 3. SAFETY 4 3.1 General 4 3.2 Regulations 4 3.3 Precautions

More information

Viega Technology GmbH & Co. KG

Viega Technology GmbH & Co. KG KIWA Covenant K90465/02 Issued: 01-01-2017 STATEMENT BY KIWA This Covenant of Kiwa ascertains that the: Raxinox multilayer piping system of stainless steel pipes with plastic covering and stainless steel/plastic

More information

SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions)

SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions) In compliance with Regulation 305/2011/EU of the European Parliament and of the Council of 9 March 2011 (the Construction Products Regulation), this certificate applies to the construction product(s).

More information

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation nnex to declaration accreditation (scope accreditation) egistration number: L 015 This annex is valid from: 01-08-2018 to 01-09-2020 eplaces annex dated: 21-03-2018 Location(s) where activities are performed

More information

Vent and air piped through a side wall (concentric termination)

Vent and air piped through a side wall (concentric termination) Vent and air piped through a side wall (concentric termination) Read before proceeding The vent piping operates with positive pressure. The vent piping must be completely sealed and securely supported.

More information

Operating and Maintenance Instructions

Operating and Maintenance Instructions EATON Germany GmbH Werk Lohmar D-53797 Lohmar Operating and Maintenance Instructions WALFORM Machine Electronically controlled - Conforms to CE MEG-WF385X Status: Sept 2011 MEG-WF385X_Stand Sept 2011 SUITABILITY

More information

BRL-K17401 Comments before.. Replaces BRL-K17401 d.d. 16 April Evaluation guideline

BRL-K17401 Comments before.. Replaces BRL-K17401 d.d. 16 April Evaluation guideline Comments before.. Replaces d.d. 16 April 2004 Evaluation guideline For the Kiwa (technical approval-with-) product certificate for District heating: flexible piping systems with plastic medium pipe for

More information

TDS 20 R / TDS 30 R / TDS 50 R

TDS 20 R / TDS 30 R / TDS 50 R TDS 20 R / TDS 30 R / TDS 50 R EN OPERATING MANUAL ELECTRICAL FAN HEATER TRT-BA-TDS20R-30R-50R-TC-001-EN Table of contents Notes regarding the operating manual... 1 Safety... 1 Information about the device...

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification

More information

BRL-K619/ Evaluation Guideline. for the Kiwa product certificate for WC-pans

BRL-K619/ Evaluation Guideline. for the Kiwa product certificate for WC-pans 2015-11-10 for the Kiwa product certificate for WC-pans V20141215 Preface This evaluation guideline has been accepted by the Kiwa Board of Experts Watercycle (CWK), in which all relevant parties in the

More information

Your roof is waiting for it PRODUCT CATALOGUE Podsufitki

Your roof is waiting for it PRODUCT CATALOGUE Podsufitki www.pdprofil.pl Your roof is waiting for it PRODUCT CATALOGUE Podsufitki The Assa gutter system is a complete system for draining rainwater from the roof, it is designed for new and renovated buildings,

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Sponsor Prepared by P.O. Box 70 NL-5750 AB DEURNE Efectis Nederland BV Lange Kleiweg 5 P.O. Box 1090 NL-2280 CB

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification

More information

SF When ordering parts please specify your model number. Sunroc

SF When ordering parts please specify your model number. Sunroc SF-7000 1 SF-1881 Valve 3 SFP-564 Drain Strainer 3 SFP-573 Drain Screw 3 SFP-566 Drain Nut 4 SF-1735 SLT Head 5 SFP-570 Lock Washer 5 SFP-500 Rubber Washer 5 SFP-526 Fiber Washer 6 SFP-574 Rubber Washer

More information

+91-8045326082 Tulsi Agriculture Products https://www.indiamart.com/tulshiagriculture/pdf1.html We Tulsi Agriculture Products, are the Manufacturer, Wholesaler, Trader of Sprinkler Nozzle, Sprinkler Tee,

More information

Greenleaf 600 Macerator Toilet Waste Pump

Greenleaf 600 Macerator Toilet Waste Pump Greenleaf 600 Macerator Toilet Waste Pump Website: Contact: www. greenleaftrade.co.nz Introduction The Greenleaf 600 toilet macerator waste pump is suitable for use in domestic waste / sewerage installations.

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification

More information

VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" THERMAL CUT-OUT THERMAL TRIP PLUG

VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4-20 x 1 THERMAL CUT-OUT THERMAL TRIP PLUG VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" 700300-013 2. THERMAL CUT-OUT 409560-001 THERMAL TRIP PLUG 409210-010 3. HEATER TERMINAL COVER VM99 2-4 HEATER TERMINAL

More information

BRL-K Evaluation Guideline. for the Kiwa product certificate for products used for treatment and / or production of drinking water

BRL-K Evaluation Guideline. for the Kiwa product certificate for products used for treatment and / or production of drinking water 25-10-2016 for the Kiwa product certificate for products used for treatment and / or production of drinking water Preface This evaluation guideline has been accepted by the Kiwa Board of Experts CWK, in

More information

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company Overview The DEMA Easy Dose is a simple and reliable chemical delivery system. Easy Dose features an electronic control system

More information

Your Key to achieving C.E Marking Compliance

Your Key to achieving C.E Marking Compliance Your Key to achieving C.E Marking Compliance As of the 1 st July 2013 The Construction Products Regulation 2011 contains clauses relating to C E marking of products. This will therefore mean that a CE

More information

HeatMaster. Assembling and installation instructions. 201 Booster. HeatMaster. HeatMaster. 200N (Gas) Booster ENGLISH FRANCAIS NEDERLANDS ESPAÑOL

HeatMaster. Assembling and installation instructions. 201 Booster. HeatMaster. HeatMaster. 200N (Gas) Booster ENGLISH FRANCAIS NEDERLANDS ESPAÑOL Heataster Assembling and installation instructions Heataster 201 Booster Heataster 200N (Gas) Booster EN 1 WANINGS 3 Who should read these instructions 3 Symbols 2 Applicable standards 2 ecommendations

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification

More information

Installation Instructions

Installation Instructions Installation Instructions 6 KW and 11.5KW Basic Circulation Water Heater and Pump Application: The Basic Circulation Water Heater has been in use for nearly 50 years, and it is the most prevalent model

More information

PowerVent Installation manual. English. Store this document in a safe place EN

PowerVent Installation manual. English. Store this document in a safe place EN PowerVent - 02 Installation manual Store this document in a safe place 959.114.01.EN en Contents Page Foreword 3 1. Introduction 3 2. CE declaration 4 3. SAFETY 4 3.1 General 4 3.2 Regulations 4 3.3 Precautions

More information

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm Safety instructions The washing machine is heavy - take care when lifting. Caution: frozen hoses may rip/burst. Do not install the washing machine in areas exposed to frost or outdoors. The washing machine

More information

Evap WTW INSTALLATION INSTRUCTIONS D

Evap WTW INSTALLATION INSTRUCTIONS D Evap WTW INSTALLATION INSTRUCTIONS (English) WWW.BRINKAIRFORLIFE.NL 614796-D English (EN) Installation instructions Humidifier for central ventilation with heat recovery KEEP WITH THE PRODUCT This product

More information

Reaction to fire classification report No C-rev.1

Reaction to fire classification report No C-rev.1 Reaction to fire classification report. 17241C-rev.1 Owner of the classification report Distributor: Vescom bv Churchilllaan 10 Sint Jozefstraat 20 5705 BK Helmond 5750 AB Deurne The Netherlands The Netherlands

More information

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual M2i-VAM-2 Cast iron condensing boiler 200i Vent/air manual Installation instructions for vent and air piping Also read and follow: 200i Boiler manual 200i Control manual This manual is intended only for

More information

Technical Guidance CE Marking of Metal Chimneys and Flues

Technical Guidance CE Marking of Metal Chimneys and Flues CE Marking of Metal Chimneys and Flues Steel Chimney Programme Schiedel is the leading producer of ceramic chimney systems in Europe, and are now regarded as the market leaders in prefabricated stainless

More information

C e r t i f i c a t e Of Conformity No.: 0560-CPD /AA/05

C e r t i f i c a t e Of Conformity No.: 0560-CPD /AA/05 C e r t i f i c a t e Of Conformity No.: 0560-CPD-10219002/AA/05 In compliance with the procedure specified in RD_090, Telefication declares as designated Notified Body for the European Construction Products

More information

User Guide Compact-7 series

User Guide Compact-7 series User Guide Compact-7 series Boiler-CH Calorifier Combi Introductory remarks Congratulations on the purchase of your Kabola Compact 7. Kabola has been a manufacturer of oil-fired heating systems since 1947.

More information

Reaction to fire classification report No C

Reaction to fire classification report No C Reaction to fire classification report. 17911C Owner of the classification report Tapetex B.V. Distributor: Vescom bv Churchilllaan 10 Sint Jozefstraat 20 5705 BK Helmond 5750 AB Deurne The Netherlands

More information

Under Water LED Universal Pool Light

Under Water LED Universal Pool Light Under Water LED Universal Pool Light 2 3 Installation Instructions for LED lights This equipment is to be installed by a person qualified in electrical and plumbing systems Technical Data LED lights Dimensions

More information

DELIVERY PROGRAMME KITCHEN BOWLS (sinks) & BATHROOM BOWLS (basins)

DELIVERY PROGRAMME KITCHEN BOWLS (sinks) & BATHROOM BOWLS (basins) DELIVERY PROGRAMME KITCHEN BOWLS (sinks) & BATHROOM BOWLS (basins) CONTENTS p 4: GENERAL NOTES: CE-label; decors p 5: GENERAL NOTES: Tolerances p 6: KITCHEN BOWLS (sinks): FULL SOLID SURFACE GETACORE BOWLS:

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification

More information

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller INSTRUCTIONS OJ-DV-Relay-Module 67439B 10/16 (OSH) 016 OJ Electronics A/S Optional module for OJ-DV motor controller OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS Contents 1. Product

More information

Installation guide VAQ E. Before installing read this guide first

Installation guide VAQ E. Before installing read this guide first Installation guide VAQ E Before installing read this guide first Introduction The operation of the Quooker VAQ E The Quooker system consists of a small tank under the sink which is connected to the Nordic

More information

HG-2000E HEAT GUN WATTS

HG-2000E HEAT GUN WATTS HG-2000E HEAT GUN 2.000 WATTS EN - INSTRUCTIONS Carefully read the instructions for use before you start using the machine. drivenbycare www.orfit.com 1 2 6 8 7 2 8 450 C 300 C 6 A E FE 550 C PVC (hard)

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com CLASSIFICATION CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE

More information

NF MARK THERMOPLASTIC MATERIAL DRAIN OR SEWER SYSTEM OPERATING WITHOUT PRESSURE

NF MARK THERMOPLASTIC MATERIAL DRAIN OR SEWER SYSTEM OPERATING WITHOUT PRESSURE Mandated by CENTRE SCIENTIFIQUE ET TECHNIQUE DU BATIMENT Certifying Body 84 avenue Jean Jaurès Champs sur Marne F 77442 MARNE-LA-VALLEE Cedex 2 rue Francis de Pressensé F 9357 LA PLAINE SAINT DENIS Cedex

More information

Guideline Construction Products Regulation (EU) 305/20122

Guideline Construction Products Regulation (EU) 305/20122 Guideline Construction Products Regulation (EU) 305/20122 Guideline: CPR 1 Table of contents Common Abbreviations... 4 Executive Summary... 5 Purpose of this guidance document... 5 Summary Requirements

More information

INSTRUCTION. Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors. Danfoss heating cable mat type 100/150

INSTRUCTION. Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors. Danfoss heating cable mat type 100/150 INSTRUCTION GB Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors NB! Read page 2 before installing the product if you intend to connect 2 mats to the same thermostat Danfoss

More information

Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual

Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual Website: Contact: www. greenleaftrade.co.nz greenleaftraders@gmail.com Greenleaf 400 Macerator Toilet Waste Pump Introduction The Greenleaf

More information

Installation guide COMBI E. Before installing read this guide first

Installation guide COMBI E. Before installing read this guide first Installation guide COMBI E Before installing read this guide first Introduction The operation of the Quooker COMBI E The Quooker COMBI E supplies boiling water and hot water. The tank is vacuuminsulated

More information

Userguide HR/HRE series Eng HRE-CH HR-CH HR Calorifier HR-Combi

Userguide HR/HRE series Eng HRE-CH HR-CH HR Calorifier HR-Combi Userguide HR/HRE series Eng HRE-CH HR-CH HR Calorifier HR-Combi ~ 1 ~ Introductory remarks Congratulations on the purchase of your Kabola HR or HRE Boiler. Kabola has been a manufacturer of oil-fired heating

More information

Test Lamp for 210 series flame detectors Non EX

Test Lamp for 210 series flame detectors Non EX Manual TC-169/1 Test Lamp for 210 series flame detectors Non EX http://sense-ware.com Check the website www.sense-ware.com for the latest information and latest version of this manual as well as the applicable

More information

Conformity assessment procedures for the Alarm Components Scheme

Conformity assessment procedures for the Alarm Components Scheme Conformity assessment procedures for the Alarm RD_070, Issue 20 This guide describes the conformity assessment procedures for Alarm Components. This Alarm certifies that Alarm Components comply with technical

More information

HRU ECO 4. user manual

HRU ECO 4. user manual HRU ECO 4 user manual 2 Safety WARNING - Do not use this appliance for functions other than those described in the booklet. - After removing the appliance from its packaging, ensure that it is complete

More information

EQ Joint High performance & Economical Price Stainless Steel welded Pipes & Tubes

EQ Joint High performance & Economical Price Stainless Steel welded Pipes & Tubes www.eqjiont.com EQ Joint High performance & Economical Price Stainless Steel welded Pipes & Tubes EQ Jointech introduce EQ joint system is based on the introduction of technology from Germany and Japan,

More information

OPERATING MANUAL CDP 115 Peltier cooling unit for waterbaths

OPERATING MANUAL CDP 115 Peltier cooling unit for waterbaths OPERATING MANUAL CDP 115 Peltier cooling unit for waterbaths Manufacturer and customer service Memmert GmbH + Co. KG Willi-Memmert-Straße 90 96 D-91186 Büchenbach Deutschland Phone: +49 (0)9122 925-0 Fax:

More information

INSTALLATION OF CENTROTHERM INNOFLUE SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

INSTALLATION OF CENTROTHERM INNOFLUE SINGLE WALL POLYPROPYLENE VENTING SYSTEMS SUPPLEMENT VENTING INSTRUCTIONS FOR INSTALLATION AND OPERATING INSTRUCTION MANUALS 238 48384 00, 238 44727 00, 238 44445 00, 238 48144 00, 238 47936 00, 238 45917 00, 238 45637 00, 238 47448 00, 238 48071

More information

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN

TTK 75 ECO OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN TTK 75 ECO EN OPERATING MANUAL DEHUMIDIFIER TRT-BA-TTK75ECO-TC-002-EN Table of contents Notes regarding the operating manual... 01 Information about the device... 02 Safety... 04 Transport...05 Start-up...05

More information

THE WIDTH AND HEIGHT OF THE LIGHT HOLE IN THE WINDOW WING IS MEASURED IN THE FOLLOWING WAY:

THE WIDTH AND HEIGHT OF THE LIGHT HOLE IN THE WINDOW WING IS MEASURED IN THE FOLLOWING WAY: V-LITE ROOF BLIND 1. MEASUREMENT OF THE WINDOW: Take measurements as indicated in the picture. Measurements are taken at the top of the frame of the window wing, not at the glazed area. The minimum depth

More information

Vaska Logburner. voorbeeld Installation guide

Vaska Logburner. voorbeeld Installation guide Vaska ogburner voorbeeld 40010627-2103 ENG Installation guide ENG 1.1 1.2 1.3 1.4 1.5 1 < < < < 1 Introduction The appliance can only be installed by a competent person in accordance with the Gas Safety.

More information

Installation Guide COMBI. Before installing read this guide first

Installation Guide COMBI. Before installing read this guide first Installation Guide COMBI Before installing read this guide first Introduction The operation of the Quooker COMBI The Quooker COMBI supplies boiling water via the Quooker tap and warm water via the existing

More information

AVS Series Air Handlers Installation Manual for CLASSIC SERIES SYSTEMS Models SC, SD, and SDH

AVS Series Air Handlers Installation Manual for CLASSIC SERIES SYSTEMS Models SC, SD, and SDH AVS Series Air Handlers Installation Manual for CLASSIC SERIES SYSTEMS Models SC, SD, and SDH AVS-ACL-IM (08/15) Copyright 2015 Earthlinked Technologies, Inc. Table of Contents Model Nomenclature... 4

More information

Technical documentation: S1 S2 S3 S4

Technical documentation: S1 S2 S3 S4 Technical documentation: S1 S2 S3 S4 1 Table of contents: 2 1. Introduction 3 1.1 Precautions 3 1.2 Transport 3 1.3 Package content 4 1.4 Use and principle of operation 4 2. Schematic diagram 4 2.1 Construction

More information

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide P/N 1072921 REV A ISS 10FEB15 Contents Product overview 2 Camera description 3 Installation 4 Programming 6 Specifications 7 Setup menu

More information

Kitchen Appliance Lift INSTRUCTION MANUAL

Kitchen Appliance Lift INSTRUCTION MANUAL Kitchen Appliance Lift INSTRUCTION MANUAL Contents Section: Headline: Page: 1. Introduction...4 2. Declaration of Conformity...4 3. Intended use - Technical data...4 Installation instructions: 4.1 Mechanical

More information

EN transition from BS 1387 Structural & Conveyance Business

EN transition from BS 1387 Structural & Conveyance Business Corus Tubes EN 10255 transition from BS 1387 Structural & Conveyance Business EN 10255 A smooth transition with Corus Install Contents 1 Introduction 2 The new standard 4 Detailed comparison 7 Comparison

More information