esserbus -PLus maximum security, minimum costs
|
|
- Margaret Little
- 6 years ago
- Views:
Transcription
1 esserbus -PLus maximum security, minimum costs
2 The innovation The latest in ringbus technology: The esserbus -PLus supplies data, signals and power, too, for the direct operation of alarm devices on only 2 wires VdS certified. l For the first time in Germany, thanks to the esserbus -PLus, the certified and approved operation of addressable, loop-powered alarm devices on the ringbus together with fire detectors and other devices is possible. The esserbus -PLus enables alarm devices to be powered directly, tolerant of short circuits and wire breaks, from the 2-wire analog loop. In other words, all participants, including alarm devices, are connected directly to the bus. In an alarm situation, the ring loop increases the voltage to 42 volts and thus provides them with the necessary power. An alarm can therefore be signalled using completely new (wiring) paths: reliably, economically and in conformity with the relevant standards. An additional and unique quality characteristic of the esserbus -PLus is the synchronous alarm signalling function. All sweep and intermittent tones are therefore no longer distorted unrecognisably by the irregular emission of several tones in the fire compartment. For a building sector affected by fire esserbus -PLus means the alarm signal is not compromised until the device itself is destroyed by fire. Thanks to the loop technology, the warning devices in the unaffected fire compartments remain functional, even without fireproof wiring.
3 The status quo Ringbus technology has been used in modern alarm systems for a long time. However, separate power sources must be provided for high-current devices, such as alarm sounders. This means unnecessary costs are incurred for additional wiring, power supply units and longer installation times. l At present all internal alarm devices must be activated in conformity with various installation standards through monitored circuits. In addition, wiring that bridges more than one fire section, must satisfy the requirements for fire resilience. With conventional resources, this can only be achieved by the costly installation of a separate power unit for each fire compartment. The only exception: the wiring system is realised with powered loop technology and the alarm devices are short circuit and open circuit-tolerant. In this way it is possible to deliver sustained operation in a fire situation.
4 The advantages The esserbus -PLus enables versatile new system components to be used. A base sounder with an integrated fire detector base and a system sounder are available as alarm devices in conformity with EN Both have 4 programmable and approved sounds. The esserbus -PLus offers numerous advantages in terms of security and cost-effectiveness. l Maximum planning reliability l Permanent monitoring of the alarm device l No detailed consideration of fire sections for alarm devices and their wiring paths is needed l Measures to ensure continued functionality of wiring systems with alarm devices can be dispensed with in most cases l Maximum security in cases of alarm l Savings due to lower material costs and shorter installation time l No separate power supply units for fire compartments l Synchronous alarm signalling
5 System components The addressable base sounder has two functions. It serves as a fully functional alarm device, which generates a uniform 360 sound pressure, and also as a mounting base for Series 9200 fire detectors. Like the base sounder, the addressable system sounder in red and white contains an isolator. Both the base sounder and the system sounder are fully integrated bus devices. Technical data common features: 4 different tones, which can be programmed using the customer data editor Warning tone to DIN Part 3 Technical data base sounder: Conforms to DIN EN 54-3, VdSapproval G Sound pressure 93 db (A)/1 m Current: < 6 ma at ring voltage, 22 ma at battery voltage Flush-mount kit available for false ceilings Up to 48 signal bases can be accommodated on one ring loop Technical data system sounder: Conforms to DIN EN 54-3, VdSapproval Sound pressure 97 db (A)/1 m Current: < 10 ma at ring voltage, 55 ma at battery voltage The sound level in the warning device is adjustable Up to 16 warning devices can be accommodated on one ring loop
6 plenum stoll & fischbach Communication GmbH, Düsseldorf Novar GmbH Dieselstraße 2 D Neuss Tel.: +49 (0) Fax: +49 (0) Johannes-Mauthe-Straße 14 D Albstadt Tel.: +49 (0) Fax: +49 (0) Internet: info@novar.de Art. No /
IQ8Quad. The highlight of every fire detection scenario. Fire detection technology
IQ8Quad The highlight of every fire detection scenario Fire detection technology 2 3 Safety is the result of efficiency and innovation l This applies to fire alarm systems too, as especially in this case,
More informationIQ8Control C Fire Alarm Panel
IQ8Control C Fire Alarm Panel State-of-the-art processor technology Maximum cable length for esserbus: 3,500 m Graphics supported, high performance programming tool Innovative alarm signalling by means
More informationAll the security you need in one housing
IQ8Quad All the security you need in one housing IQ8Quad: The highlight of every fire detection scenario Fire detection technology 02 03 Safety is the result of efficiency and innovation This applies to
More information561-MB256 plus. Intruder alarm control panel. Performance features
561-MB256 plus Intruder alarm control panel The intruder alarm control panel 561-MB256 plus is designed for use in private and commercial zones and is highly suitable for setting up medium to large-sized
More informationNew dimensions in fire detection technology FlexES control: the dawning of a flexible, trendsetting system
New dimensions in fire detection technology FlexES control: the dawning of a flexible, trendsetting system Flexible: the concept One control panel many possibilities Fire protection solutions are as individual
More informationtools 8000 The perfect all-round tool: tools 8000 Programming and service software for alarm systems Fire detection technology
tools 8000 The perfect all-round tool: tools 8000 Programming and service software for alarm systems Fire detection technology 02 03 The circle is complete: programming from installation to maintenance
More informationTOOLS 8000 SOFTWARE FOR THE ENTIRE LIFE CYCLE OF YOUR FIRE DETECTION SYSTEMS
TOOLS 8000 SOFTWARE FOR THE ENTIRE LIFE CYCLE OF YOUR FIRE DETECTION SYSTEMS ONE SOFTWARE FOR ALL TASKS tools 8000 is the complete software tool for your fire detection systems. It accompanies you during
More informationIQ8Wireless. Radio technology: flexible functionality IQ8Wireless intelligent, wireless fire protection. Fire detection technology
IQ8 Radio technology: flexible functionality IQ8 intelligent, wireless fire protection Fire detection technology Starts where cables end: pioneering fire protection with IQ8Wire Also in the field of fire
More informationFlexES Control Flexible solutions with the modular fire detection system
Flexible solutions with the modular fire detection system APPROVAL REPORT Project No: 0003042587 Class: 3010 Product Name: Examination for Approval of FlexES and Peripherals Product Type: Fire Alarm System
More informationQuick Selection Guide Fire Systems LSN Periphery
Local SecurityNetwork Easy wiring Auto configuration capability (self-learning mode) Central programming of all device configurations from the panel Flexible network structure (Loop, stub, T-tap & mixed
More information13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba
Cerberus PRO Cerberus FIT Interbases DBS721, DBS728, DBS729 Sounder interbase, sounder beacon interbase, sounder interbase with supplementary optical indication for the automatically addressable detector
More informationDBS721, DBS729 Sounder interbase, Sounder beacon interbase
DBS721, DBS729 Sounder interbase, Sounder beacon interbase For the automatic addressable detector bus C-NET Cerberus PRO Sounder interbase DBS721 and sounder beacon interbase DBS729 11 selectable tones,
More informationIQ8Quad. The highlight of every fire detection scenario. Fire detection technology
The highlight of every fire detection scenario Fire detection technology 2 3 Safety is the result of efficiency and innovation four fire safety tasks, one device l This applies to fire alarm systems too,
More informationFDS229-R / FDS229-A Alarm sounder with supplementary optical indication
FDS229-R / FDS229-A Alarm sounder with supplementary optical indication For the automatic addressable detector bus C-NET and FDnet Cerberus PRO Sinteso Alarm sounder with 11 tonalities selectable, 2 activation
More informationInterbases. Sinteso FDSB221, FDSB228, FDSB229
Sinteso Interbases FDSB221, FDSB228, FDSB229 Sounder interbase, sounder beacon interbase, sounder interbase with supplementary optical indication for the automatically addressable detector bus FDnet Addressed
More informationThe EN54 Part 2 and 4 Fire System
Scope of work: To design, supply, install and commission a Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54 Part 2 and 4 Fire
More informationIntegrated security systems. The security spectrum Systems for comprehensive building security
Integrated security systems The security spectrum Systems for comprehensive building security Integrated security systems Security to the fourth power Contents 04 M24 integrated security panel 08 M48
More informationViewguard Motion detctors PIR and DUAL detectors
Motion detctors and DUAL detectors Passive infrared sensor Passive infrared and microwave sensor AM DUAL AM DUAL Variations detectors: - AM /BUS-1 VdS Class C EN 5131-1 and EN 5131-2-2, grade 3 - /BUS-1
More informationA Soft (R)evolution. For a flexible future: modular fire alarm technology by ESSER
A Soft (R)evolution For a flexible future: modular fire alarm technology by ESSER A new outlook for the future: F uture-oriented fire alarm systems need to fulfill a complex range of requirements, including
More informationPRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10
PRODUCT INFORMATION PI 38.43 Sounder SG 200 Page 1 of 10 Table of Contents 1. Product Description............................... 3 2. Features......................................... 3 3. Functional Description............................
More informationIDENTLOC. Intrusion Detection Systems. Performance Features
IDENTLOC Intrusion Detection Systems The crime statistics show that burglaries are among the crimes committed most frequently. A burglary usually proceeds in two stages, first the unauthorized breaking
More informationAvailability, Reliability, False Alarm Resistance Best Practice in Fire Alarm Systems. FIRE PROTECTION OF ROLLING STOCK 2 rd March 2017
Availability, Reliability, False Alarm Resistance Best Practice in Fire Alarm Systems FIRE PROTECTION OF ROLLING STOCK 2 rd March 2017 1. Introduction 1905 Compagnie des Wagons-Lits 2000 Rail Services
More informationFire Alarm Control Panel. System Maintenance and Log Book
Fire Alarm Control Panel System Maintenance and Log Book Fire Alarm System Maintenance A fire alarm system must provide early and reliable warning of the outbreak of fire. To achieve this, the system remains
More informationIDENTLOC. Intrusion Detection Systems. Performance Features
IDENTLOC Intrusion Detection Systems The crime statistics show that burglaries are among the crimes committed most frequently. A burglary usually proceeds in two stages, first the unauthorized breaking
More information561-MB48. Intruder Alarm Control Panel
561-MB48 Intruder Alarm Control Panel Maximum security for all eventualities The intruder alarm control panel 561-MB48 is designed for use in private and commercial buildings and is highly suitable for
More informationSignaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.
Signaling Devices Acoustic Signaling Devices 28 Optical Signaling Devices 30 26 Signaling Devices Acoustic Signaling Devices Acoustic Signaling Devices MSS300-SA SG 200 DS 10 LSN/GLT GLT GLT GLT Operating
More informationConcepts for the secure networking of large building complexes
Concepts for the secure networking of large building complexes Secure conditions: competence & responsibility Due to our extensive product portfolio, you can realize projects with us which, because of
More informationSita200plus. 200detectors. Single loop analogue addressable System
Single loop analogue addressable System Fast short circuit isolator in every device 15 combinations of smoke & heat detection modes Loop length up to 2km long with spurs INTELLIGENT FIRE TECHNOLOGY A D
More informationELECTRONIC SOUNDER STROBE Model : AVD-C407
ELECTRONIC SOUNDER STROBE Model : AVD-C407 MULTRON range of combination Electronic Sounders with Strobe Lights are designed to complement our Fire Alarm products both technically and aesthetically as an
More informationAuer - Signal tower ECO Ø70 mm modular
products Panel Signalling Signal Towers - Auer Auer - Signal tower ECO Ø70 mm modular Modular system with bayonet fitting for quick assembly LED or conventional filament lamp for cost sensitive applications
More informationIntelligent Security & Fire Ltd
Product Data Sheet Mx-4000 Series User Manual MX-4100, MX-4200, MX-4400, Mx-4400/LE & Mx-4800 Fire Alarm Control Panels The operation and functions described in the manual are available from Software Versions
More informationSolution F2. Fire Alarm Control Panels one step ahead.
Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution
More informationCerberus FIT conventional system
Cerberus FIT conventional system Combining intelligent signal processing and easy installation for reliable fire detection and alarming www.siemens.com/cerberus-fit Reliable, intelligent and cost-efficient
More informationFireClass. Introducing a new class of fire detection
FireClass Introducing a new class of fire detection Who and what is FireClass? FireClass is a revolutionary new class of commercial fire detection system. Comprising a comprehensive range of fully approved
More informationAP200 SERIES INTELLIGENT ALARM DEVICES
Tech Data Sheet D0170GB Fire Detection /01 AP00 SERIES INTELLIGENT ALARM DEVICES Intelligent AP00 series alarm devices for FX fire detection system The intelligent AP00 series alarm devices are used in
More informationAP200 SERIES INTELLIGENT ALARM DEVICES
Tech Data Sheet D017GB1 Fire Detection /01 AP00 SERIES INTELLIGENT ALARM DEVICES Intelligent AP00 series alarm devices for FX NET fire detection system The intelligent AP00 series alarm devices are used
More informationFC722 Fire control panel
FC722 Fire control panel Series FS720 (MPXS) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as
More informationThe complete conventional fire warning system
The complete conventional fire warning system www.espuk.com MAG2P 2 Zone Fire Panel 2 programmable zones Active end of line monitoring and head removal 30 fire detectors per zone Unlimited number of call
More informationThe EN54 Part 2 & 4 Fire System
Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54
More informationOperation Instruction. VARIODYN D1 Comprio HO.GB / AA. Technical changes reserved Honeywell International Inc.
Operation Instruction VARIODYN D1 Comprio 798666.HO.GB0 07.2013 / AA GB Technical changes reserved. 2013 Honeywell International Inc. Intended use This product may only be used for the applications outlined
More informationFC724 Fire control panel
FC724 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as
More informationFC722 Fire control panel
FC722 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as
More informationClino Guard. Safety without Compromise
Clino Guard Safety without Compromise Protection for disoriented persons Clino Guard, the disorientation care system from Ackermann, considerably simplifies the supervision of disoriented persons. If a
More informationX10 Mini, Midi & Maxi
Industrial Sounder, Sounder Beacon X0 Mini, Midi & Maxi Installation Manual EAT X0 Mini, Midi & Maxi Installation Manual (90F) Contents Overview and purpose... Product assembly... Select wiring method......
More informationVTG-32E Spatial Sounder 24Vdc EN54 part 3 approved
The VTG32E family of sounders have been designed to cover a wide spectrum of applications. The 24 volt EN543 approved version is for use with conventional fire alarm systems including SAVWIRE two wire
More informationZerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions
Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions EN54-3:2001+A1:2002+A2:2006 EN54-7:2000+A1:2002+A2:2006 EN54-25:2008 0359 Electro Detectors Ltd. Electro
More informationVIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm
VIMPEX Sounder Range Fire Alarms Banshee Electronic Sounders FlashDome EN 54-3 Evacuation Audible Alarm BS 5839-1 Beacons The range of sounders, beacons, sounder beacons and accessories represents the
More informationintelligent solutions
Alco is one of the leading intelligent solution providers of Fire Detection System. Security System and Public Addressing System in the United States of America. Based in California since 1992, we have
More informationVdS 5477en : (01) Key deposit boxes
VdS 5477en : 2004-03 (01) Key deposit boxes We wish to thank the Police, in particular the Kommission Polizeiliche Kriminalprävention der Länder und des Bundes - KPK (German Police commitee for crime prevention)
More informationTrueAlarm ES Analog Sensing
TrueAlarm ES Analog Sensing UL, ULC, CSFM Listed; FM Approved* Features TrueAlarm addressable sensor base with 520 Hz sounder TrueAlarm sensor bases with 520 Hz tone require a TrueAlarm photoelectric,
More informationAddressable Loop Powered Visual Alarm Devices
Addressable Loop Powered Visual Alarm Devices About Who is? has a long and proud tradition in fire detection. Founded in Munich in 1877 as Elektrotechnische Fabrik Alois it quickly became a recognized
More informationUSER MANUAL CEF AP28 CONTROL PANEL
USER MANUAL CEF AP28 CONTROL PANEL AP28 WARNINGS This product has mains voltage present within the housing. Please take the necessary precautions in not allowing any liquid to spill on or into the housing.
More informationSystem 800 Addressable Fire Detection & Alarm System
SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools
More informationFC724 Fire control panel
FC724 Fire control panel Series FS720 (IP5) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as
More informationIntelligent Security & Fire Ltd
full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04
More informationIntelligent addressable fire alarm control panel
Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity
More informationZerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions
Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions EN54-3:2001+A1:2002+A2:2006 EN54-5:2000+A1:2002 EN54-25:2008 0359 Electro Detectors Ltd. Electro House Edinburgh
More informationSOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon
SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon alarm devices For fire detector and extinguishing systems Loud alarm signal clearly recognizable as a danger signal even in noisy environments
More informationFire control panels FC360
Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses
More informationFire control panel detect 3004 plus and accessories
Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be
More informationMINERVA MX. 800 Series Ancillary Equipment
An extensive range of ancillary modules has been specifically designed for use with the MX range of Fire Controllers. The 800 range of ancillary modules provide the MX Fire Controller with a wide degree
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) BExS110D and BExS110D-R Sounder For use in Flammable Gas and Dust Atmospheres BExS110D BExS110D-R 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT
More informationThe EN54 Part 2, 4 and 13 Fire System
Scope of work: To design, supply, install and commission an Analogue Addressable Fire Alarm Control System in accordance with the details specified herein and in accordance with supplied drawings The EN54
More informationintelligent fire alarm ID60series panels
intelligent fire alarm ID60series panels features LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as
More informationICO ADDITIONAL ACCESSORIES CO 2 INCUBATOR ICO
ICO ADDITIONAL ACCESSORIES CO 2 INCUBATOR ICO Manufacturer and customer service MEMMERT GmbH + Co. KG Willi-Memmert Strasse 90-96 91186 Büchenbach Germany Phone: +49 (0)9122 925-0 Fax: +49 (0)9122 14585
More informationMETAL DETECTOR MODEL NO: MD1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: /08
METAL DETECTOR MODEL NO: MD1000 PART NO: 4501200 OPERATION & MAINTENANCE INSTRUCTIONS 05/08 INTRODUCTION Thank you for purchasing this CLARKE Metal Detector. Before you try to use this product, read this
More informationTouch Screen 1 loop Addressable Fire Alarm Panel
evolution 1 Touch Screen 1 loop Addressable Fire Alarm Panel The evolution 1 control panel offers complete compatibility with the award winning range of Nittan evolution detection and alarm devices and
More informationTrueAlert Addressable Notification Appliances
UL, ULC Approved* TrueAlert Addressable Notification Appliances Audible Notification Appliances; Multi-Tone Horns with 520 Hz Output Features Individually addressed and controlled TrueAlert ES multi-tone
More informationINSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder
INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder 1) Introduction The Appello tone and speech annunciation sounder has three different styles in AC and DC. A105NAPPX
More informationXP95 Sounder VAD Base
PP2478/2016/Issue 5 XP95 Sounder VAD Base FUNC TION The XP95 Sounder Visual Alarm Device (VAD) Bases incorporates a standard mouting base with a loop-powered sounder VAD. It is used to signal a fire alarm
More informationCEILING SPEAKER SYSTEMS F-2352C
INSTRUCTION MANUAL CEILING SPEAKER SYSTEMS F-2322C F-2352C F-2322C F-2352C TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 3 3. FEATURES... 3 4. NOMENCLATURE AND DIMENSIONS... 4
More informationEvolution Analogue Addressable Fire System
Addressable Fire System optimum fire safety systems solutions High speed FSK protocol, uniquely resistant to noise Up to 254 addresses per loop for flexible system design Built to exceptional marine standards
More informationEx Products Highest level of safety under the most difficult conditions
Ex Products Highest level of safety under the most difficult conditions Fire protection for potentially explosive areas The Ex Products Nuclear power Logical: The avoidance of flammable materials still
More informationSmoke Alarm FERION 1000 O
Smoke Alarm FERION 1000 O en Smoke Alarm Table of Contents en 3 Table of contents 1 Graphics 4 2 Introduction 6 3 Mounting 7 4 Maintenance 9 5 Technical data 10 6 Customer Service 11 Bosch Sicherheitssysteme
More informationInstallation and Operating Instruction
Installation and Operating Instruction Automatic Fire Detectors Series 900 Ex (i) 9893 0.00 GB Technical changes reserved! 0 Installation and Operating Instruction Automatic Fire Detectors Series 900 Ex
More informationADDITIONAL ACCESSORIES 100% ATMOSAFE. MADE IN GERMANY.
ADDITIONAL ACCESSORIES 100% ATMOSAFE. MADE IN GERMANY. www.memmert.com www.atmosafe.net Manufacturer and customer service Memmert GmbH + Co. KG Willi-Memmert-Straße 90 96 D-91186 Büchenbach Germany Phone:
More informationfour Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1
four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 ANALOGUE FIRE DETECTION VIGILON COMPACT FEATURES & BENEFITS four Keep it Simple All Vigilon devices connect onto the same 2
More informationAn introduction to... Sigma
An introduction to... Sigma XT+ Sigma XT+ Overview The Sigma XT+ 21000 series are the latest additions to the Sigma family of control equipment from Kentec Electronics Limited. The Sigma XT+ range combines
More informationGenesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet
Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet Table 1: Models Description Low frequency (520 Hz) horn, white housing, no FIRE marking, standard output clear strobe light Low frequency (520
More informationPATROL SOUNDERS 110/120 db(a) PA 10 / PA 20
PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.
More informationModular Fire Panel 5000 Series Just as flexible as your plans
Modular Fire Panel 5000 Series Just as flexible as your plans 2 One modular system does it all Unbeatable flexibility With the Modular Fire Panel 5000 Series, Bosch is again redefining the market: With
More informationInstruction Manual EVA-S6 Base
Instruction Manual EVA-S6 Base Sounder Base NITTAN COMPANY, LIMITED 1-54-5 SASAZUKA, SHIBUYA-KU, TOKYO 151-8535, JAPAN http://www.nittan.com Before Installation Please read these instructions carefully
More informationPATROL SOUNDERS 100/105 db(a) PA 1 / PA 5
PRODUCTS AUDIBLE SIGNALING DEVICES PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5 PATROL the new generation of sounders. Three dimensional innovation. Safe; an incorrect installation is virtually impossible.
More informationBasic Fire Alarm SystemTraining. Arman Alnasar
Basic Fire Alarm SystemTraining Arman Alnasar Agenda Introduction to Esser 10 min Product Overview 5 min Control Panels 30 min Detectors 20 min Field Devices Alarm Devices 20min 10 min Management & Interface
More informationTouchpoint Pro Flexible Gas Control System
Gas Detection Touchpoint Pro Flexible Gas Control System THE IDEAL SAFETY SYSTEM Honeywell s Touchpoint Pro makes gas control system design, installation, configuration and operation simple. Touchpoint
More informationMulti line separator module
Sinteso Cerberus PRO Multi line separator module FDCL221-M Multi line separator module, addressed (FDnet/C-NET) Automatic module with several separate line separators Formation of stub lines (T-branches)
More informationINPUT / OUTPUT MINI MODULES
INPUT / OUTPUT MINI MODULES APPLICATION The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors
More informationSolution F1. Fire Control Panels the new generation
Solution F1 Fire Control Panels the new generation Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F1 The Concept The Solution F1 Fire Control Panel range is a new
More informationHAWK 8000 CONNECTED BUILDING MANAGEMENT
HAWK 8000 CONNECTED BUILDING MANAGEMENT Benefit from a powerful unified platform that controls multiple systems and connects diverse devices utilised in modern building management applications. All systems
More informationNoby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book
Noby-448 User Operating Manual & Log Book Page 1 of 12 Fire Control Panel User Operating Manual & Log Book TABLE OF CONTENTS Page Introduction 1 Keypad Operation 2 LED Indications 3 What to do in the event
More informationFire control panel for modernization
Sinteso Fire control panel for modernization FC2030 Modular, pre-assembled fire control panel with integrated, user-friendly operating unit for gradual migration to Sinteso. Fire control panel for a maximum
More informationTECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:
Biddle Air Systems Limited St. Mary s Road, Nuneaton,Warwickshire CV AU. Tel: + 0 78 Fax: + 0 77 Email: sales@biddle-air.co.uk http://www.biddle-air.co.uk F.H. Biddle B.V. P. O. Box, NL-988 ZG Kootstertille,The
More informationTrueAlarm Analog Sensing
UL, ULC Approved* TrueAlarm Analog Sensing TrueAlarm Analog Sensors Photoelectric and Heat; Standard Bases and Accessories Features TrueAlarm analog sensing provides: Digital transmission of analog sensor
More informationCEILING SPEAKER SYSTEM F-122C INSTRUCTION MANUAL TABLE OF CONTENTS 7. REPAINTING THE SPEAKER SAFETY PRECAUTIONS... 2
INSTRUCTION MANUAL CEILING SPEAKER SYSTEM F-122C TABLE OF CONTENTS 1. SAFETY PRECAUTIONS... 2 2. GENERAL DESCRIPTION... 2 3. FEATURES... 3 4. NOMENCLATURE AND DIMENSIONS... 3 5. INSTALLATION... 4 6. REMOVING
More informationAddressable Detectors & Bases
Edwards Signaling Catalog u Intelligent Initiating Addressable Detectors & Bases Detectors: E-PD, E-PHD, E-HD Bases: B4U, RB4U, IB4U, SB4U Overview Edwards intelligent addressable detectors are meticulously
More informationL-Series, Indoor Strobes and Horn Strobes
Notification Appliances L-Series, Indoor Strobes and Horn Strobes Indoor Selectable-Output Strobes/Horn Strobes for Ceiling Applications General The L-Series audible visible notification products offer
More informationCeiling air diffuser INDULTHERM INDULTHERM-e
Technical Information Ceiling air diffuser INDULTHERM INDULTHERM-e Effective cooling and heating with a diffuser Thermomechanical or electrical switching Draught-free air distribution for cooling down
More information(68.52) X. June 2000 supersedes February vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS
(68.52) X June 2000 supersedes February 2000 vigilon ADVANCED FIRE DETECTION & ALARM SYSTEMS VIGILON SYSTEM ARCHITECTURE Repeat Panel Spur Manual Call Point T-breaker Alarm Sounder Max loop length 1000m
More informationIntellia Sounder Bases and Sounder Beacon Bases
Intellia Bases and Beacon Bases The Base and Beacon Base are a local-area alarm devices designed for indoor use. They can be connected only to detection systems using Intellia detectors and FX control
More informationFire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology
Fire-Cryer Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX Shaping Alarm Technology Fire-Cryer Plus The Fire-Cryer range of voice sounders was first introduced to the market by Vimpex in 1999.
More information