S F IT 6" / 8"HES. Quick Installation Guide. franklinwater.eu

Size: px
Start display at page:

Download "S F IT 6" / 8"HES. Quick Installation Guide. franklinwater.eu"

Transcription

1 GB D S F IT 6" / 8"HES Quick Installation Guide franklinwater.eu

2 Summary Page English 5-19 Deutsch Svenska French Italian

3 GB 6" / 8"HES Quick Installation Guide franklinwater.eu

4 Summary Page Control modes and necessary sensor technologies 5 Battery Installation Procedure IP66 / IP21 5 Connection Description 6"/ 8" HES Sytem Standard 6 System and Connection Description 6" HES solar 7 Connections Motor and Option cards 8 6"/8" System Performance Data 400V-50Hz 9 Keypad button Overview 10 Start-Up-Wizard 10 Basic Con guration 11 / 12 Con guration 13 / 14 Con guration h 15 Con guration P 16 Direct Mode (DM) 17 Manual Mode (MM) 17 Display Messages 18 Con guration S (Solar) 19 Additional safety instructions System can automatically restart (Solar) - the appropiate safety precautions should be taken. See page 19 DANGER 4

5 Control modes and necessary sensor technologies Process reference Control reference Flow meter Pressure sensor Level sensor PT100 sensor & Drive slot card Flow switch (digital) - Flow No (Optional) mandatory Optional P mandatory mandatory H mandatory mandatory P - pressure No (Optional) Yes* mandatory Optional Q mandatory mandatory H mandatory mandatory H - level No (Optional) Yes* mandatory Optional Q mandatory mandatory P mandatory mandatory Direct Mode No Yes** No No Optional No Manual Mode No Yes* Solar No Yes* mandatory *please consult Franklin Electric ** need to be evaluated to PLC Battery Installation Procedure IP Battery Installation Procedure IP21 5

6 Connections 6" / 8" HES Standard System Standard I/O Terminal Signal Vref Reference output Analogue input, 2 AI1+ voltage or current Control Reference: AI1, Terminals 2(+), 3(GND) 3 AI1- Analogue input (Connection depending Default setting [V] common on settings) Analogue input, 4 AI2+ voltage or current Analogue input 5 AI2- common 6 24V out 24V aux. voltage 7 GND I/O ground Fig. 1: Input/Output Terminals Process Reference: AI2, Terminals 4(+), 5(GND) Default setting [ma] 8 DI1 Digital input 1 Start/Stop: DI1, Terminals 6(+24V), 8(DI1) 9 DI2 Digital input 2 External Fault: DI2, Terminals 6(+24V), 9(DI2) 10 DI3 Digital input 3 Manual Operation: DI3, Terminals 6(+24V), 10(DI3) 11 CM Common for DI1 - DI6* 12 24V out 24V aux. voltage 13 GND I/O ground 14 DI4 Digital input 4 Set Point - : DI4, Terminals 6(+24V), 14(DI4) 15 DI5 Digital input 5 Set Point + : DI5, Terminals 6(+24V), 15(DI5) 16 DI6 Digital input 6 Reset: DI6, Terminals 6(+24V), 16(DI6) 17 CM Common for DI1 - DI6* Analogue output, 18 AO1+ voltage or current Analogue output 19 AO-/GND common V in 24V aux. input voltage A RS485 Serial bus, negative B RS485 Serial bus, positive * Can be isolated from ground, see chapter wire Sensor Supply + 24V (Terminal 6) Common - AI+ (Terminal 2/4*) 3- wire Sensor Common - Common(Terminal 7) AI- (Terminal 3/5*) 4- wire Sensor Fig. 1.1 : Sensor connection * depending on Reference AI - (Terminal 3/5*) Common(Terminal 7) Supply + 24V (Terminal 6) 0/4-20mA AI+ (Terminal 2/4*) Supply + 24V (Terminal 6) Common Common(Terminal 7) 0/4-20mA+ AI + (Terminal 2/4*) 0/4-20mA - AI- (Terminal 3/5*) Form standard I/O Relays From term. #6 RUN From term. #13 Terminal 21 RO1/1 22 RO1/2 23 RO1/3 24 RO2/1 25 RO2/2 26 RO2/3 Signal Relay output 1 Relay output 2 Operation: RO1, Terminals 22(+24V), 23 Warning/Fault: RO2, Terminals 25(+24V), 24 Fig. 2: Relais Output Connection IP21 IP66 AI1 AI2 A0 AI1 AI2 A0 Fig. 3: Analog Input/Output Signal Selection IP21 IP66 Fig. 4: Digital Input Selection 6

7 6" HES Solar System DC Power Solar PV Array G IP 66 HES Drive Solar B B Heat Sink Flow Switch (required for operation): D Filter C Derating 40 C - 100% 50 C - 75% 60 C - 50% DC Disconnect optional part A Control Switch Full F Pump/Motor Control Switch Empty E H Alternate AC Power (Optional) 2 Level Control Switch Operation optional parts: Connections 6" HES Solar System Standard I/O Terminal Signal Vref Reference output Analogue input, 2 AI1+ voltage or current Analogue input 3 AI1- common Analogue input, 4 AI2+ voltage or current Analogue input 5 AI2- common 6 24V out 24V aux. voltage 7 GND I/O ground 8 DI1 Digital input 1 Start/Stop: DI1, Terminals 6(+24V), 8(DI1) 9 DI2 Digital input 2 Flow Switch: DI2, Terminals 6(+24V), 9(DI2) 10 DI3 Digital input 3 Manual Operation: DI3, Terminals 6(+24V), 10(DI3) 11 CM Common for DI1 - DI6* 12 24V out 24V aux. voltage 13 GND I/O ground 14 DI4 Digital input 4 Control Switch Empty DI4, Terminals 6(+24V), 14(DI4) 15 DI5 Digital input 5 Control Switch Full DI5, Terminals 6(+24V), 15(DI5) 16 DI6 Digital input 6 Reset: DI6, Terminals 6(+24V), 16(DI6) 17 CM Common for DI1 - DI6* Analogue output, 18 AO1+ voltage or current Analogue output 19 AO-/GND common V in 24V aux. input voltage A RS485 Serial bus, negative B RS485 Serial bus, positive * Can be isolated from ground, see chapter Fig. 5: Input/Output Terminals 7

8 Connections Motor and Option cards L1 U/T1 U1 U2 U ~ _ du L2 V1 dt V/T2 V2 V M L3 W/T3 W1 W2 W 3~ PE PE PE PE PE ~ _ Color code FE Motor Short Lead: U - brown V - grey W - black Fig. 6: Supply and motor connection Color code FE PT100 Lead: black 2 - blue 3 - brown Fig. 7: PT100 card (left slot) Fig. 8: PT100 connection Jumper X2 Jumper X4 Fig. 9: OPTB1, 6 DI/DO card Fig. 10: OPT-B4, 1AI/2AO card Red Yellow Green X6 X1 Bus Connector Jumper Interface Board - Connector word 1: motor current word 2: process value word 3: control value word 4: PT100 temperature word 5: motor speed (RPM) word 6: process reference word 7: relay output word 8: output frequency Fig. 11: OPTE5, Pro bus card (right slot) 8

9 6" HES System Performance Data 400V-50Hz 400V/50Hz X16 P N [kw] Thrust F [kn] n N [min -1 ] I N [A] I A / I * N [A] [%] cos [%] T N [Nm] 4 15, ,95 12,9 1 5,5 15, ,95 17,5 1 T A / T N * [Nm] 7,5 15, ,5 0,95 23, X23 9,3 15, ,5 0,95 29, , , , ,5 0,95 41, X , ,5 0,95 46,1 1 18,5 15, , , , X , ,5 0,95 82, , ,5 0,95 95, X , ,95 117,8 1 8" HES System Performance Data 400V-50Hz 400V/50Hz X01 P [kw] Thrust F [kn] n N [min -1 ] I N [A] I A / I * N [A] [%] cos [%] T N [Nm] ,3 0, ,3 0, , T A / T N * [Nm] ,5 0, ,5 0, X ,3 0, , ,7 0, ,2 0, X ,2 0, , ,4 0, Performance data are based on measurements with Franklin Electric original equipment! 9

10 Keypad buttons Overview Move backward in menu Exit edit mode Reset faults with long press Scroll menu up Increase value Move cursor left Move cursor right Stop button Scroll menu down Decrease value Start button Enter active level/item Start-Up-Wizard RUN READY I / O Multimonitor 113 Nominal Amps Nominal Amps Amps Motor Speed 23.0A 20.0A 2300rpm Setpoint Feedback PT m3h 49.5m3h 23.7 C CtrlSetPnt Ctrl. Act. Ctrl. Max. 0.0[-] 0.0[-] 0.0[-] Monitor M 2.1 Multimonitor Trend Curve (12) Basic (12) Monitor M 2.1 Fieldbus Data (20) Trend Curve (4) Basic (1) WIZARD 1171 M Startup wizard Startup wizard M Activate Help Add to Favorites 10

11 Language Selection 802 English Daylight saving 2204 Russia US EU OFF Time :14:11 Min: Max: Year Min: Max: Date Min: Max: During the next steps please enter System Data. Output Filter 1810 du/dt Filter * * PT100 installed 1834 Yes No STOP Not RDY I / O Please note, a PT100 sensor has to be used to measure Motor- Temperature, connected to OPT- BH, terminals 1, 2 and 3. Refere to Quick Installation Guide. next steps please enter Motor Nameplate Data. Motor Nom. Voltage V 400 V 230 V 220 V Nominal Amps 113 Min: 0.26A Max: 5.20A 1.90 A Motor Nom. Frequency Hz 120 Hz During the next steps please enter Duty Point Data. Duty Point Flow 1828 Min: 1.0m³/h Max: 500.0m³/h 75.0 m³/h * for other languages please contact Franklin Electric Europa GmbH ** is only shown and selectable if PT100 Option card is installed 11

12 Basic Con guration Duty Point Head 1829 Pump Install. Depth 1815 Casing Diameter m 50.0 m mm Min: 1.0m Max: 1000m Min: 1.0m Max: m See Fig.12 Min: 100.0mm Max: mm Min. Water Colum 1818 Min: 0.5m Max: 200.0m 10.0 m See Fig.12 During the next steps please enter Process Data. Process Reference 1819 Q [m³/h] Page 13 h [m] P [bar] h P Page 14 Page 16 Direct Mode DM Page 17 Manual Mode MM Page 17 Solar S Page 19 Process Reference has to be connected to AI2, terminals 4(+) and 5(-). Control reference 1 has to be connected to AI1, terminals 2(+) and 3(-). Q, H Flow Inducer SLEEVE PUMP INSTALL. DEPTH Min. Water Column Level Probe Installation Depth Ø D Fig

13 Process Reference 1830 Voltage mA mA Voltage Proc. Ref. End Scale 1034 Min: 0.00m3h Max: 600.0m3h m3h ProcRefSetPntSource 332 Fieldbus Standard Please note, if AI2 is used as Voltage input, you have to set DIP- Switch AI2 to U. Refere to Quick Installation Guide. Control Reference V V ProcRefSetPntSource 332 Fieldbus Standard Proc. Ref. Set Point 167 Min: 31.12m3h Max: m3h 73.0 m3h Control Reference 1820 On Control Reference 1820 On Please note, an analog level meter or analog pressure sensor has to be used as Control Reference 1, connected to AI1, terminals 2(+) and 3(-). See Fig. 1, 1.1 without rotation will start. You can Stop-Button at any time. Having ready to start. RUN READY I / O Multimonitor 113 Nominal Amps Nominal Amps Amps Motor Speed 23.0A 20.0A 2300rpm Setpoint Feedback PT m3h 49.5m3h 23.7 C CtrlSetPnt Ctrl. Act. Ctrl. Max. 0.0[-] 0.0[-] 0.0 [-] 13

14 Con guration h[m] Ctrl. Ref. Signal 1822 h [m] P [bar] Control Reference V V Current LPP Install. Depht 1888 Min: 0.1 m Max: m 20.0m Current If Control Reference Signal is ma, you have to set. DIP- Switch AI1 to I. Refer to Quick Installation Guide. Control Reference mA mA Voltage See Fig. 3 LPP Max. Range 1887 Min: 0.1 m Max: m 10.0m Ctrl. Ref. Set Point 1823 Min: 0.0 m Max: m 0.0 m without rotating will start. You can Stop-Button at any time. Having ready to start. Multimonitor 113 Nominal Amps Nominal Amps Amps Motor Speed 23.0A 20.0A 2300rpm Setpoint Feedback PT m3h 49.5m3h 23.7 C CtrlSetPnt Ctrl. Act. Ctrl. Max. 10.0m 10.5m 25.0 m P[bar] Ctrl. Ref. Signal 1822 h [m] P [bar] Control Reference V V Current Ctrl. Ref. End Scale 1836 Min: 1.0bar Max: bar 25.0 bar Current If Control Reference Signal is ma, you have to set. DIP- Switch AI1 to I. Refer to Quick Installation Guide. Control Reference mA mA Voltage See Fig. 3 Ctrl. Ref. Set Point 1823 Min: 0.5bar Max: 100.0bar 6.0 bar without rotating will start. You can Stop-Button at any time. Having ready to start. Multimonitor 113 Nominal Amps Nominal Amps Amps Motor Speed 23.0A 20.0A 2300rpm Setpoint Feedback PT m3h 49.5m3h 23.7 C CtrlSetPnt Ctrl. Act. Ctrl. Max. 6.0bar 4.5bar 25.0bar 14

15 Con guration h Process Ref. Signal 1830 LPP Install. Depth 1888 LPP Max. Range 1887 ProcRefSetPntSource mA mA Voltage 20.0m Min: 0.1 m Max: m Min: 0.1 m Max: m 10.0m Fieldbus Standard Voltage Please note, if AI2 is used as Voltage input, you have to set DIP- Switch AI2 to U. Refere to Quick Installation Guide. Process Ref. Signal V V ProcRefSetPntSource 332 Fieldbus Standard See Fig. 3 Proc.Ref.Set Point 167 Min: 0.00m Max: 40.00m See Fig. 1, m be used as Control Reference, connected to AI1, terminals 2(+) and 3(-). Current Control Reference V V Current Ctrl. Ref. End Scale m3h Min: 1.0 m3h Max: m3h is ma, you have to set. DIP- Switch AI1 to I. Refer to Quick Installation Guide. Control Reference mA mA See Fig. 3 Ctrl. Ref. Set Point 1823 Min: 31.1m3h Max: 150.0m3h 31.1m3h without rotating will start. You can Stop-Button at any time. Having ready to start. RUN READY I / O Multimonitor 113 Nominal Amps Nominal Amps Amps Motor Speed 23.0A 20.0A 2100rpm Setpoint Feedback PT m 9.0m 23.5 C CtrlSetPnt Ctrl. Act. Ctrl. Max. 31.1m3h 45.0m3h 150.0m3h 15

16 Process Ref. Signal 1830 Proc. Ref. End Scale 1034 ProcRefSetPntSource mA mA Voltage Min: 0.0 bar Max: bar 16.0 bar Fieldbus Standard Voltage Please note, if AI2 is used as Voltage input, you have to set DIP- Switch AI2 to U. Refere to Quick Installation Guide. Process Ref. Signal V V ProcRefSetPntSource 332 Fieldbus Standard See Fig. 3 Proc.Ref.Set Point 167 Min: 0.0 bar Max: 40.0 bar 8.0 bar be used as Control Reference 1, connected to AI1, terminals 2(+) and 3(-). Control Reference V V Current Ctrl. Ref. End Scale m3h Min: 1.0 m3h Max: m3h See Fig. 1, 1.1 Current is ma, you have to set. DIP- Switch AI1 to C. Refer to Quick Installation Guide. Cotrol Reference mA mA See Fig. 3 Ctrl. Ref. Set Point 1823 Min: 31.1 m3h Max: m3h 31.1 m3h without rotating will start. You can Stop-Button at any time. Having ready to start. RUN READY I / O Multimonitor 113 Nominal Amps Nominal Amps Amps Motor Speed 23.0A 20.0A 2300rpm Setpoint Feedback PT bar 6.5bar 23.7 C CtrlSetPnt Ctrl. Act. Ctrl. Max. 31.1m3h 45.0m3h 100.0m3h 16

17 ProcRefSetPntSource 332 Fieldbus Standard without rotating will start. You can Stop-Button at any time. Having ready to start. RUN READY I / O Multimonitor 113 Nominal Amps Nominal Amps Amps Motor Speed 23.0A 20.0A 2300rpm Setpoint Feedback PT % 88.9 % 23.7 C CtrlSetPnt Ctrl. Act. Ctrl. Max. 0.0 [-] 0.0 [-] 0.0 [-] ProcRefSetPntSource 332 Fieldbus Standard If Process Reference has to be connected to AI2, terminals 4 (+) and 5(-). Process Ref. Signal mA mA Voltage Voltage Please note, if AI2 is used as Voltage input, you have to set DIP- Switch AI2 to U. Refere to Quick Installation Guide. Process Ref. Signal V V See Fig. 3 Start/Stop has to be connected to terminal 6 (24V+) and DI1, terminal 8 or can be used by keypad (green/red push buttom). during operation by using DI4 (frequency DOWN) and DI5 (frequency UP) without rotating will start. You can Stop-Button at any time. Having ready to start. Frequency 105 Nominal Amps Output frequency Hz Amps 23.0A 20.0A 89.80Hz PT C 17

18 Display Messages Failure Messages RUN READY ALARM I / O STOP READY ALARM I / O RUN READY ALARM I / O RUN READY ALARM I / O Sleep Alarm Active Code: 81 Alarm Hold Code: 57 PT100 Temperature Alarm Active Code: 70 PT100 Temperature Alarm Active Code: 70 Control Reference Signal out of range. Device is sleeping. Remedy: Check that motor is connected to frequency converter and Run command will not be removed befor completion of Motor temperature critical. Device sleep imminent. Motor temperature critical. Device is sleeping. STOP READY ALARM I / O READY ALARM I / O STOP READY ALARM I / O READY ALARM I / O Sleep Alarm Active Code: 81 Sleep Alarm Active Code: 81 Sleep Alarm Active Code: 81 Sleep Alarm Active Code: 81 Process Reference Signal too low. Device is sleeping. Process Reference Set Point not reached for a period of time. Device is sleeping. Process Reference Signal not reached during a period of time. Control Reference Signal out of range. Device is sleeping. STOP READY ALARM I / O READY ALARM I / O Sleep Alarm Active Code: 81 Sleep Alarm Active Code: 81 Control Reference Signal out of range for several times. Level switch Empty and Full have not plausible switch settings. Warning Faults READY I / O READY I / O Current Limit 1081 Fault: Hold Code: 82 Next Start-Delay active. Please wait, drive will start automatically. Too high Process Refence at low speed for a period of time. Motorcurrent reached Current-Limit. Check Setting and Pump. 18

19 (Attention: During the next steps please enter Solar Panel Data. Panel Voc 1870 Min: 10.0V Max: 100.0V 37.0V Panels per Row 1871 Min: 1 Max: During the next steps please enter control data. On Time : :00 ProcRefSetPntSource 332 Fieldbus Min: 00:00 Max: 20:00 Min: 09:00 Max: 23:59 Standard DI 3 Bypass Solar 1894 Automatic Restart 1896 Yes Yes No No DI 3 Bypass Solar 1894 Yes No Automatic Restart 1896 Yes No Warning: By setting Automatic Restart to yes the motor will start automatically after sun is coming back. Please refer QIG for safety information. Level Switch 1892 One Level Switch Two Level Switches No Level Switch Level Switch 1893 Normal Open (NO) Normal Closed (NC) The Level Switch (Full) has to be connected to terminal 6 (24V+) and DI 5, terminal 15. See Fig. 5, page 7 Level Switch 1892 One Level Switch Two Level Switches No Level Switch Level Switch 1893 Normal Open (NO) Normal Closed (NC) The Level Switch (Full) has to be connected to terminal 6 (24V+) and DI 5, terminal 15. The Level Switch (Empty) has to be connected to terminal 6 (24V+) and DI 4, terminal 14. See Fig. 5, page 7 Level Switch 1892 One Level Switch Two Level Switches No Level Switch Warning: Without Level Switch there is risk to over flood the tank! A Flow Switch has to be connected to DI 2, terminal 6(24V+) and terminal 9. Refer to Quick Installation Guide. See Fig. 5, page 7 without rotating will start. You can Stop-Button at any time. Having ready to start. Frequency 105 Nominal Amps Hz Amps 23.0A 21.9A Motor speed DC- link Voltage 2856 rpm 679 V 19

20 Notes 20

21 Notes 21

22 Franklin Electric Europa GmbH Rudolf-Diesel-Strasse Wittlich/Germany Tel.:+49 (0) 6571 / Fax:+49 (0) 6571 / info@franklinwater.eu 22

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING Manual Contents Introduction...3 Valve compatibility...3 Features...3 Application examples...3 Ordering...3 Operating the EKC 347...4-5

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system, SILVER C Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is

More information

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) IRDH375_D00124_01_D_XXEN/07.2018 Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Product

More information

GRUNDFOS INSTRUCTIONS. Dedicated Controls. Service instructions

GRUNDFOS INSTRUCTIONS. Dedicated Controls. Service instructions GRUNDFOS INSTRUCTIONS Dedicated Controls Service instructions Contents 1. Symbols used in this document... 3 2. Identification... 3 2.1 Dedicated Controls... 3 2.2 CU 361... 5 2.3 IO 351B... 6 2.4 Separate

More information

Intelligent Security & Fire Ltd

Intelligent Security & Fire Ltd full installation, commissioning and operating manuals can be downloaded from www.haes-systems.co.uk combined addressable / conventional fire alarm control panel User Guide Approved Document No. MFBU-04

More information

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv

More information

Sequence of operation

Sequence of operation Sequence of operation IPS 4000 secondary variable speed control File No: 90.96 Date: february 21, 2013 Supersedes: new Date: new sequence of operation ips 4000 2 list of abbreviations: adj: Field Adjustable

More information

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS

CU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS GRUNDFOS STRUCTIONS CU 300 Installation and operating instructions No contact Overvoltage Undervoltage Dry running Speed reduction Overtemperature Overload Sensor alarm Other languages www.grundfos.com/cu300-manual

More information

Insulation fault evaluator EDS460-DG

Insulation fault evaluator EDS460-DG Insulation fault evaluator for localising insulation faults in DC IT systems with a number of branch circuits where high system leakage capacitances are involved Preliminary data sheet TDB108021en/09.2008

More information

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors

More information

Tri-Stack Smart System

Tri-Stack Smart System Tri-Stack Smart System TM Notes & Warnings - The protection provided by this equipment may be impaired if it is not used in the manner specified herein. - Ensure all wiring meets applicable national and

More information

RES-210 (-211, -220, -221) / RES-420

RES-210 (-211, -220, -221) / RES-420 RESISTR GB Replacing RES-2xx/ Replacement Instructions The RESISTR temperature controller can be used as an alternative to the following controllers of the series 200 : RES-210: Analog temperature display,

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-59 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

FIL-SPL Flow-through heater for central heating USER MANUAL

FIL-SPL Flow-through heater for central heating USER MANUAL FIL-SPL Flow-through heater for central heating with 0-10 V EP 15-30 control unit USER MANUAL Kaukora LTD. D106159 r3.0 Contents 1. Important information... 5 Safety information... 5 General... 5 Marking...

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Bender Incorporated 700 Fox Chase, Coatesville PA 1930 Tel.: (800) 356-466 Fax: (610) 383-7100 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control function

More information

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS SCADA INTERFACE INSTRUCTIONS - OPTION 21S - FOR A36D/TPSD SYSTEMS with option 500 and 550. A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE OPTION 21S INSTRUCTIONS This manual is valid for A36D/TPSD Chargers

More information

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012670 / 08.2013 isopv425

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options Table 4 External Maintenance Switch Configuration Options External Maintenance Switch Options Installed with Interlock Option Option Auxiliary Contact Status open = On Test position or Maintenance position,

More information

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification February 11, 2019 Master Panel Product Description The Master Panel shall provide lead/lag control and time based, automatic rotation of up to eight (8) boilers, when used in conjunction with LMV3 or LMV5

More information

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances _D00108_00_D_XXEN/05.2015 ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances

More information

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH CONTROL PANEL INTERFACE USING THE AUTO/OFF/MANUAL SWITCH With the switch set to AUTO, the engine may crank and start at any time without warning. Such automatic starting occurs when utility power source

More information

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15 with coupling device AGH675-7 and AGH675-7MV15 Device combination for insulation monitoring in unearthed AC, AC/DC and DC power systems (IT systems) IRDH275BM-7_D00123_03_D_XXEN/01.2017 with coupling device

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

FC700A Fire detection control unit

FC700A Fire detection control unit FC700A Fire detection control unit Synova 4-16 Loop analogue addressable control panel 128 devices per loop (SynoLOOP) and up to 1000 devices per panel Up to 24 collective lines for Synova TM 600 serie

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems) ISOSCAN EDS460/490 EDS461/491 Insulation fault locators with control and display function for EDS systems (insulation fault location systems) EDS460-490_D00085_01_D_XXEN/01.2017 ISOSCAN EDS460/490 EDS461/491

More information

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL.

SIRA srl. Installation and user manual. Consolle/Digit Remote LCD Annunciator. Remote LCD Annunciator INSTALLATION & USERS MANUAL. Page 1 / 15 Installation and user manual Page 2 / 15 Sira s.r.l. reserves the right to make modifications to this manual and the product described herein without prior notice. Sira s.r.l. shall not be

More information

EasyTronic III MANUAL SERVICE

EasyTronic III MANUAL SERVICE rev.6 EasyTronic III MANUAL SERVICE General characteristics: Power supply 24 Vac ±15% Max consumption at 24Vac 300mA Relay outputs 6 Maximum relay current 8 A res. Serial standard RS232 2 Serial standard

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

PowerLogic ION Setup Meter Configuration Software Configuration Guide

PowerLogic ION Setup Meter Configuration Software Configuration Guide PowerLogic ION Setup Meter Configuration Software Configuration Guide 70002-0293-03 12/2010 Conventions Used in this Manual This section describes the symbols and terminology used in this guide. Symbols

More information

GLOBAL. InstallatIon & operation manual

GLOBAL. InstallatIon & operation manual InstallatIon & operation manual INDEX 1. INTRODUCTION... 5 2. FEATURES AND FUNCTIONS 2.1 Reporting Options... 2.2 Interfaces... 2.3 Programming... 2.4 Indicators and Controls...... 6 6 6 6 6 3. INSTALLATION...

More information

CU 300 GRUNDFOS INSTRUCTIONS. Installation and operating instructions

CU 300 GRUNDFOS INSTRUCTIONS. Installation and operating instructions GRUNDFOS STRUCTIONS CU 300 Installation and operating instructions No contact Overvoltage Undervoltage Dry running Speed reduction Overtemperature Overload Sensor alarm Declaration of Conformity We Grundfos

More information

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS Engineering Guideline pac-carriers Type 9195 for Yokogawa ProSafe-RS 2 Engineering Guideline / Yokogawa ProSafe-RS 06.06.2017 Integrated solutions for Yokogawa R. STAHL offers a wide range of customized

More information

Micro-VPAC IIT LSC - Lift Station Controller. User Manual. Version 1.0.2

Micro-VPAC IIT LSC - Lift Station Controller. User Manual. Version 1.0.2 Micro-VPAC IIT LSC Micro-VPAC IIT LSC - Lift Station Controller User Manual Version 1.0.2 Table of Contents ii CHAPTER: Table of Contents Contents Introduction 5 General 6 Control Description 6 Manual

More information

ACS-30-EU-VIA-DU-20-MOD

ACS-30-EU-VIA-DU-20-MOD Multi-application heat tracing Control & Monitoring in commercial and residential buildings Surface Snow melting sensor Module Description The Raychem ACS-30-EU-VIA-DU-20-MOD Module for the ACS-30 system

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL MYRIAD TPC VISIT OUR WEBSITE SIGMACONTROLS.COM MYRIADI&O062705 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING 7,8

More information

N M AirControl AHU. Control manual

N M AirControl AHU. Control manual N 10.63 M 03-2016 AirControl AHU Control manual EN CONTENTS PAGE 1 - MONITORING AND CONTROL 2 1.1 The program 2 1.2 The HMI terminal 2 1.3 The controller 4 1.4 Description of the air handling units 4

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

RESISTRON. Replacing RES-102/RES-420. Replacement Instructions. Comparison of RES-102 / RES-420. Dimensions. Temperature indication (actual value)

RESISTRON. Replacing RES-102/RES-420. Replacement Instructions. Comparison of RES-102 / RES-420. Dimensions. Temperature indication (actual value) RESISTRON GB Replacing / Replacement Instructions The RESISTRON temperature controller can be used as an alternative to the older controller type. The mechanical outlines are identical. The connection

More information

QS941A Controller User Interface

QS941A Controller User Interface Product Manual Select Code 167-792-184 Comcode CC848816612 Issue 3 November 2009 Notice: The information, specifications, and procedures in this manual are subject to change without notice. Lineage Power

More information

Operation Manual. Programmable Logic Controller

Operation Manual. Programmable Logic Controller Operation Manual Programmable Logic Controller Part No. 9983-0000-E01 / January 2018 OPERATION MANUAL TABLE OF CONTENTS CUSTOMER SERVICE 3 CONTACT INFORMATION 3 ORDER INFORMATION 3 INTRODUCTION 4 THE PROCESS

More information

Dryer Master DM510 Commissioning Guide

Dryer Master DM510 Commissioning Guide COMMISSIONING GUIDE Dryer Master DM510 Dryer Moisture Systems Inc. 640 Superior Drive Waterloo, Ontario Phone 519.725.4700 Fax 519.885.4300 USA & Canada Toll Free 1-888-318-0009 E-mail: info@dryermaster.com

More information

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS

ELECTROPROJECT GTV-A POWER SUPPLY FOR DOOR MAGNETS ELECTROPROJECT POWER SUPPLY FOR DOOR MAGNETS Innovative and carefully thought out Always the right drive ELECTROPROJECT AANDRIJFTECHNIEK ElectroProject has evolved over the last 75 years from a technical

More information

eed quality electronic design USER s MANUAL

eed quality electronic design USER s MANUAL eed quality electronic design www.dem-it.com eed www.qeed.it info@qeed.it ANALOG SIGNAL DISPLAY Q-DISP-T USER s MANUAL The displays Q-DISP-T, prepared for mounting on the back panel, 96x48mm, will allow

More information

S/601 Controller Installation Manual

S/601 Controller Installation Manual Checked Version Release date QA V4.6.5 PC1 EN 02.07.2012 2011 S/601 Controller Installation Manual FLOW CONTROL PC1 - Pump controller Introduction Thank you for using the S/601 flow, batch and pump control

More information

DC 60 & DM 60 displays

DC 60 & DM 60 displays USER MANUAL DC 60 & DM 60 displays BALTIC FLEXAIR ENERGY AIRCOOLAIR COMPACTAIR FLATAIR (& Inverter) AQUALEAN DC60-DM60-IOM-1310-E www.lennoxemea.com Summaries 1 Display DC60 1.1 Introduction... 2 1.2

More information

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V IR1575_D00116_00_D_XXEN/05.2015 Insulation monitoring device for unearthed AC/3(N)AC systems up to 480

More information

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training PowerWizard Level 1.0 & Level 2.0 Control Systems Training New Systems Current Systems Systems Comparison Level 1 Level 2 Level 3 Level 4 PowerWizard Level 3.0 PowerWizard Level 4.0 Overview Common parts

More information

PolyGard Digital Gas Controller DGC-05 RS-485 Bus

PolyGard Digital Gas Controller DGC-05 RS-485 Bus PolyGard Digital Gas Controller DGC05 RS485 DESCRIPTION Gas measuring controller series for continuous monitoring and warning of toxic, combustible and refrigerant gases and vapours. The gas controller

More information

PLW PLW TOP LOAD. PV Hot Water Controller. PV Solar Hot Water Controller PLASMATRONICS. Manual. Read this before installing. Rev. U3.

PLW PLW TOP LOAD. PV Hot Water Controller. PV Solar Hot Water Controller PLASMATRONICS. Manual. Read this before installing. Rev. U3. TOP LOAD PV Hot Water Controller oc PV Solar Hot Water Controller PLASMATRONICS PLASMATRONICS Manual Read this before installing Rev. U3. 27112017 PLASMATRONICS 2 User Guide LCD Display TOP LOAD PV Hot

More information

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual 026-1501 Rev 5 3-20-03 Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: (770) 425-2724 Fax: (770) 425-9319 ALL RIGHTS

More information

Gas Controller Module GC-06

Gas Controller Module GC-06 Page 1 Oct. 2015/2 Measuring, warning and controlling module for toxic, combustible and refrigerant gases and vapours. The gas controller series GC-06 is designed in accordance with the standard EN 50545-1.

More information

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TT-1343 5/06b INSTALLATION INSTRUCTIONS Original Issue Date: 8/03 Model: Automatic Transfer Switches Equipped with Series 1000 Programmable Controller Market: ATS Subject: Remote Annunciator Kits GM28938-KP1,

More information

Installation manual Washer extractor

Installation manual Washer extractor Installation manual Washer extractor W555H Type W.55.H Original instructions 438 9054-30/EN 2017.11.06 Contents Contents 1 Safety Precautions...5 1.1 General safety information...6 1.2 Commercial use

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

REPEATER FS5200R INSTRUCTION MANUAL

REPEATER FS5200R INSTRUCTION MANUAL REPEATER FS5200R INSTRUCTION MANUAL Instruction Manual Page1 CONTENTS 1. Introduction... 3 2. Function... 3 3. Technical data... 3 4. Contents of delivery... 4 5. General information... 5 6. Duty Mode...

More information

Danfoss gas detection Controller unit

Danfoss gas detection Controller unit Data sheet Danfoss gas detection Controller unit The gas detection Controller Unit is used for a centralized monitoring and warning of hazardous gas concentrations. The input signals for the controller

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Rev 7 06-APR MultiFlex Condensing Unit Board (CUB-II and CUB-TD) Installation and Operation Manual

Rev 7 06-APR MultiFlex Condensing Unit Board (CUB-II and CUB-TD) Installation and Operation Manual 026-1705 Rev 7 06-APR-2010 MultiFlex Condensing Unit Board (CUB-II and CUB-TD) Installation and Operation Manual 1640 Airport Road, Suite 104 Kennesaw, GA 31044 Phone: 770-425-2724 Fax: 770-425-9319 ALL

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007

User Manual. PolyGard Gas Controller MGC3. Two-Channel Analog Gas Controller Serial Number _E _0907. September 2007 PolyGard Gas Controller MGC3 Two-Channel Analog Gas Controller Serial Number _E _0907 User Manual September 2007 January 04, 2016 Revision Specifications subject to change without notice. USA 160104 Page

More information

UniPOS Wireless Fire Alarm Control Panel VIT 01 WIRELESS FIRE ALARM CONTROL PANEL VIT01 INSTRUCTION MANUAL

UniPOS Wireless Fire Alarm Control Panel VIT 01 WIRELESS FIRE ALARM CONTROL PANEL VIT01 INSTRUCTION MANUAL WIRELESS FIRE ALARM CONTROL PANEL VIT01 INSTRUCTION MANUAL Revision 8/10.13 Instruction manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.3. 4.4. 5. 5.1. 5.2. 5.3. 6. 6.1. 6.2. 6.3. 7. 7.1 7.2. 7.3. 8. 8.1. 8.2. 8.3.

More information

Humidity Controller Specification and Installation Instructions. Model HRO20

Humidity Controller Specification and Installation Instructions. Model HRO20 Model Description The Humidity Controller is an advanced application to control relative humidity for general purpose applications. They are specially designed to control humidifiers and dehumidification

More information

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software La Marche Manufacturing Company www.lamarchemfg.com DNP 3.0 Serial (RS232/RS485) and Ethernet (TCP/IP) SCADA Interface for A36D & TPSD Chargers with S2A-341S and S2A-383S communication cards. Option 21P,

More information

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel Synova TM Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches unnecessary Automatic

More information

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel Synova Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches, punch cards, etc. unnecessary

More information

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 9. Commissioning Checklist. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc. MISSION CRITICAL Air Conditioning Systems Series 9 Commissioning Checklist S9-CL2017.doc ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 2 S9-CL2017.doc Commissioning

More information

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63 Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.

More information

Inverter scroll compressors VZH

Inverter scroll compressors VZH Application guidelines Inverter scroll compressors VZH028-035-044 R410A http://cc.danfoss.com VZH028-035-044 - single compressors VZH scroll specificities...6 Inverter compressors...7 Compressor size...7

More information

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7 MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7 VISIT OUR WEBSITE SIGMACONTROLS.COM MYRIAD DPC MANUAL 013114 1 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features

More information

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note Product Overview: The Pertronic F4 Remote LED Mimic / Aux Relay Module F4-RMAX is an optional extra for the Pertronic F4 conventional 4-zone fire alarm panel. This board enables the fire alarm panel to

More information

Fire control panels FC360

Fire control panels FC360 Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses

More information

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products Document 475595 Microprocessor Controller for Tempered Air Products Reference Guide for the Microprocessor Controller Please read and save these instructions. Read carefully before attempting to operate

More information

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V 05/06/2018 DESCRIPTION Autodialer to be fitted behind the cop or on top of the car / retrofit. A Connector for Esse-ti power supply (12 Vdc) B Micro SD Card

More information

DEIF A/S. Operator s Manual. Multi-line 2/version 2-GS E (UK) SW version 2.4X.X. Display readings. Push-button functions.

DEIF A/S. Operator s Manual. Multi-line 2/version 2-GS E (UK) SW version 2.4X.X. Display readings. Push-button functions. Multi-line 2/version 2-GS 4189340253E (UK) SW version 2.4X.X Display readings Push-button functions DEIF A/S Alarm handling Service menu Log list DEIF A/S, Frisenborgvej 33 Tel.: +45 9614 9614, Fax: +45

More information

Fire control panels FC726 FC726-XA

Fire control panels FC726 FC726-XA Fire control panels FC726 FC726-XA Modular, pre-confectioned, microprocessor-controlled fire control panel for up to max. 1512 device addresses Integrated, user-friendly operating unit Detection and automatic

More information

Remote alarm indicator and test combination MK2430

Remote alarm indicator and test combination MK2430 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Tel.: 040 807-0 Fax: 040 807-259 Remote alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC

More information

Built-on speed controller for GMPM plug fan with permanent magnet motor

Built-on speed controller for GMPM plug fan with permanent magnet motor Air Comfort air comfort Centriflow 3D Plug fan GMPM Built-on speed controller» Installation and Operation Built-on speed controller for GMPM plug fan with permanent magnet motor Content Page 1. Introduction...

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

Compact Genset Controller, CGC 400 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

Compact Genset Controller, CGC 400 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list OPERATOR'S MANUAL Compact Genset Controller, CGC 400 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS QUICK USER GUIDE FOR, 2 & 4 ZONE PANELS INDICATORS COLOUR INDICATION MON FAULT Yellow On when a fault condition has occurred, or if no other fault Led is on, this indicates 24v auxiliary fuse failure.

More information

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice. BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice. via Florida Z.I. Valtesino - 63013 GROTTAMMARE (AP) - ITALY Installation and Quick guide: DUAL

More information

FLÄkT WOOdS BuILT-ON FrEQuENCY CONVErTEr CENTRIFLOW 3D PLUG FAN WITH PERMANENT MAGNET AND ASYNCHRONOUS MOTOR

FLÄkT WOOdS BuILT-ON FrEQuENCY CONVErTEr CENTRIFLOW 3D PLUG FAN WITH PERMANENT MAGNET AND ASYNCHRONOUS MOTOR AIR COMFORT AIR TREATMENT 9932 GB 2016.10.28 FLÄkT WOOdS BuILT-ON FrEQuENCY CONVErTEr CENTRIFLOW 3D PLUG FAN WITH PERMANENT MAGNET AND ASYNCHRONOUS MOTOR» INSTALLATION, MAINTENANCE AND COMMISSIONING INTrOduCTION

More information

M1000 Alarm Annunciator

M1000 Alarm Annunciator Data Sheet Alarm Annunciator Reliable Supervision and Control 10 inputs with LED indications Supports both NO/NC input contacts 10 open collector outputs Built-in siren relay Text label for alarm descriptions

More information

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION 968 AFMS AFMS TECHNICAL SPECIFICATION 08/07 Ref B ATV-ELEKTRONIK GMBH WIENER STRASSE 228 A-4030 LINZ +43 732 301600 FAX. +43 732 301600 21 Page 2 Table of contents General Introduction...3 Overview...3

More information

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen TS Touchscreen Kits for use with LMV3, LMV5 and RWF Controls June 25, 2018 Touchscreen Description Plate Kit Enclosure TS series touchscreen kits provide a human machine interface (HMI) with a Siemens

More information

Instructions OJ EC-Controller (Translation of the original) BA-ESR_OJ-EC /2013

Instructions OJ EC-Controller (Translation of the original) BA-ESR_OJ-EC /2013 Instructions OJ EC-Controller (Translation of the original) EN BA-ESR_OJ-EC 1.0 02/2013 Contents Contents... 2 1. Revision Index... 2 2. Introduction... 3 3. Features... 4 4. Installation... 4 5. Operation...

More information

Pioneer-R16 Gas Monitor Operator s Manual

Pioneer-R16 Gas Monitor Operator s Manual Pioneer-R16 Gas Monitor Operator s Manual Edition 7/2/97 RKI INSTRUMENTS, INC RKI Instruments, Inc. 33248 Central Ave, Union City, CA 94587 (510) 441-5656 Chapter 1: Description About the Pioneer-R16 Gas

More information

Manual & Technical Documentation V1.1

Manual & Technical Documentation V1.1 Manual & Technical Documentation V1.1 tado Smart Thermostat tado Extension Kit ENGLISH Content Product Packages Compatibility Intelligence & Security Functions Smart Thermostat Usage Menu Structure Special

More information

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Modular Standard HP Chiller 1/4 screw compressor with Carel driver Program for pco¹ pco 2 and pcoc Modular Standard HP Chiller 1/4 screw compressor with Carel driver Manual version 1.0 25 September 2003 Program code: FLSTDmMSDE Do we want you to save you time and money?

More information

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

DUAL MONITORED INPUT/OUTPUT UNIT BN-305 DUAL MONITORED INPUT/OUTPUT UNIT BN-30 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection

More information

XC1008D -XC1011D- XC1015D and VGC810

XC1008D -XC1011D- XC1015D and VGC810 Electronic Controller for Compressor Racks XC1008D -XC1011D- XC1015D and VGC810 Instructions Manual INDEX 1. GENERAL WARNING 4 1.1 PLEASE READ BEFORE USING THIS MANUAL 4 1.2 SAFETY PRECAUTIONS 4 2. WIRING

More information