SWITCH VIDEO, AUDIO & CONTROLS MANUALLY OR IN SYNCHRONIZED SEQUENCE

Size: px
Start display at page:

Download "SWITCH VIDEO, AUDIO & CONTROLS MANUALLY OR IN SYNCHRONIZED SEQUENCE"

Transcription

1

2 SWITCH, & CONTROLS MANUALLY OR SYNCHRONIZED SEQUENCE THE AUTO/MANUAL SWITCHERS EXS123 & EXS143 Incorporating cascadable ext. sync. generator the EXS123 and EXS143 can be connected to a large system and lock its ext. sync. generator to a master generator or become a master generator through its in-out cascade connectors. Having separate monitor outputs and separate input selectors, the 8 channel switcher EXS123 and 4 channel switcher EXS143 provide separate selection for manual and sequential channels. The incorporated alarm homing and the VCR playback are routed through the sequential monitor output. Common Manual Auto/Manual With the sequential set to off both outputs provide common manual selection. The two selectors provide separate manual and sequential outputs. THE AUTO/MANUAL SWITCHER/CONTROLLERS EXS125 & EXS145 The EXS125 and EXS145 auto switchers offer user friendly by-pass setting keys, indicated by multi color LEDs and sequence time setting of 4 sec. ~ 45 sec. through a rotary control. Both the 8 channels EXS125 and the 4 channels EXS145 auto/manual switchers provide selective controls for pan, pan speed, tilt, zoom and focus. Selecting any of the camera s manual selector keys will divert the control keys to the selected camera, the auxiliary lines however are common to all camera auxiliary lines. REMOTE ON OFF ILIARY REMOTE ON-OFF Remote auto on switching of camera auxiliary equipment is provided to all four or eight cameras in parallel through the cameras D connectors. Similar to the motor control, the auxiliary on-off employs +12V DC level to switch the camera s auxiliary equipment on. Separately from the cameras auxiliary line which is switched on along with the power switch, the front panel mounted auxiliary key offers other auxiliary controls. It is designed to activate a related auxiliary equipment through the convenience of auxiliary key at the switcher s front panel. The auxiliary key s dry contacts are connected through the monitor s A/V D connector and are limited to 30mA current level.

3 THE ALARM CIRCUIT Auto switcher models EXS123, EXS125, EXS143 and EXS145 incorporate auto homing alarm inputs and dry relay contacts alarm output, while EXS123 & EXS125 offer in addition a sequencing display of multi alarms at 4 sec. interval. 8P D FOUR OR EIGHT ALARM PUTS AND AUTO HOMG The alarm is activated by contact closure, grounding any of the alarm input lines activates the alarm. 8 pin D jack provides four or eight alarm input connections. When alarm is triggered, the auto homing circuit stops the sequencing process and automatically diverts the alarmed channel input and locks it to the sequential output. If multiple alarms are triggered simultaneously the nearest camera in sequence will be locked to the output (EXS143 & EXS145), or sequencing alarms at 4 sec. interval will commence (EXS123 & EXS125). Relay contacts activate time lapse VCR recording or other auxiliary alarm equipment during the alarm and during the 60 sec. alarm holding time. Front panel mounted LED flashes to indicate alarm. OPTIONAL ALARM BUZZER EBZ900 Optional alarm buzzer EBZ900 is provided with plug and adhesive base for simple installation inside the switcher. The EXS120/EXS140 series switchers rear panel uses standard connectors as shown; 8P D BNC ALARM PUT CONTACTS AND LED DICATORS SIMPLIFIED CONNECTION WITH CHOICE OF CABLES, PLUGS AND ASSEMBLIES A/V & CONTROL - 8 pin D ALARM PUT - 8 pin D / - 8 pin D A/V - 8 pin D VCR & ALARM - 8 pin D VCR / ALARM VCR - A/V & CONTROL A/V & VCR / ALARM VCR - A/V & CONTROL A/V & Elbex offers D connectors, Pigtail (EC7) terminated with D connector at one end and terminals at the other and multi core cables for connecting motorized cameras with audio. 8 pin D plug EDM900 Pigtail (EC7) with D plug, terminals and cover assy. EDM900TML EC4 Shield Multi core cables EC Shield DESK TOP STALLATION THROUGH STACKG Coax Control wires 2 Coax Control wires EC7 Shield 2 Coax Control wires Elbex switchers and camera controllers EXS120 or EXS140 series can be stacked like HiFi components one on top of the other and under Elbex B/W 9, 12 and 14 monitors. Indentations to accomodate rubber feet are provided on the switcher cover, to neatly stack several units high as shown; OPTIONAL 19 RACK MOUNTG KITS ERM920 single rackmount For use with EXS120 series. ERM940 single/dual rackmount For use with EXS140 series. All the necessary panels and hardware for mounting single or dual units are included. SGLE DUAL

4 SELECT SELECT AUTO SEQ SPEED / THE MANUAL SWITCHERS EXS120 & EXS140 The EXS120 and EXS140 uses mechanical passive switch to switch over video, audio and control s. Mechanical switching requires no power and both the 8 inputs EXS120 and the 4 inputs EXS140 switchers do not use power, therefore in order to generate s to the control and auxiliary lines from a separate power source, access is provided through the A/V monitor 8 pin D connector. The manual models EXS120 and EXS140 switch 4 control lines in addition to the audio and video, thereby providing switched connections for custom controls of pan, tilt, zoom, focus and auxiliary. Alternatively, two control lines for example, can be used for switching of telemetry control transmission via twisted pair to reduce the numbers of transmitters in telemetry system as shown: RX RX RX RX TOTAL FLEXIBILITY WITH FOUR CONTROL AND ILIARY LES Telemetry receivers Telemetry TX Motorized cameras SWITCHER EXS120. SWITCHER EXS140 LEFT UP DOWN RIGHT THE MANUAL SWITCHER/CONTROLLERS EXS122 & EXS142 Both the 8 channels EXS122 and the 4 channels EXS142 manual switchers provide selectable controls for pan, pan speed, tilt zoom and focus. Selecting any of the camera s selector keys will divert the control keys to the selected camera. The auxiliary lines however are common to all camera auxiliary lines (+12V via 680 resistor) and the auxiliary key output to the A/V monitor 8 pin D connector. + 12V GND or VCC etc. VCR PLAYBACK RG KEY Unlike other manual switchers which provide for connection to the monitor through the VCR in-out terminals the EXS122 and EXS142 incorporate a buffered video output to the VCR. Such arrangement permits a simplified playback of the VCR through a playback selector key which reroutes the monitor to display the VCR. VCR Common Systems The monitor and VCR are connected to same output. EXS120/EXS140 series The VCR and the monitor are connected to a separate buffered output. VCR Video out REC. P.B. Switcher Monitor Switcher Video out Monitor

5 AUTO SEQ SPEED / PLA, SIMPLE AND EXPENSIVE CONTROLS WITH SGLE WIRE FOR EACH MOTORIZED FUNCTION, ALONG WITH VIA THE COAX CABLE - AN ADVANCED CONCEPT FROM ELBEX TO YOUR ADVANTAGE. EXT SYNC PUT LE +12V LEFT DOWN The motor control circuits require only single control wire for each motorized function. Applying high or low logic levels to the control wires will operate the motors in reciprocal directions, wherein; high is +12V and low is ground. The simplicity of high- open-low control system to operate the motors permits flexibility in custom making control panels by using three position lever switches as shown: TRUTH TABLE RIGHT UP SIMPLIFIED MOTOR CONTROL CIRCUIT WIRG OPEN Current: 10mA max THE +12V LE LE LE NG LE The ext. sync generator transmits 25Hz (CCIR/PAL) or Hz (EIA/NTAC) vertical sync pulses via the video coax cable in reverse direction to the video propagation. The positive 5V-8Vp-p pulses are detected by the camera s video line sensor, which resets the camera s SSG to its first field. The second field is generated by the camera s SSG for perfect 2:1 interlace. To transmit ext. sync pulses through the video coax cable and through line amplifiers such as distributors and boosters in reverse direction to the video propagation, the consists of full range of boosters/cable compensators and distributors incorporating ext. sync by-pass circuit. The by-pass circuit positioned across the line equipment transfers the ext. sync pulses from the amplifier output side to its input side as shown: Ext. sync pulses UP DOWN PRCIPLE OF OPERATION By-pass By-pass EXM990 The motors are controlled by standard 3 position lever switchers. RIGHT LEFT EX420 Dome camera EXDT30/35/40 & 300 series Distributors EXBR30/35 sries Cable compensators EXS125 MODEL NO. AND EASY SELECTION CHART FUNCTION 8P D 8P D EXT SYNC REMOTE ON OFF MODELS BNC 4 PUTS BNC 8 PUTS EXT. SYNC MANUAL SEQUENTIAL DUAL PUTS ILIARY SPEED AUTO HOMG ALARM ALARM BUZZER EXS120 EXS122 EXS123 EXS125 EXS140 EXS142 EXS143 EXS145 Controls lines are switched, allowing control via separate equipment.

6 SELECT SELECT AUTO SEQ / EXS123 EXS122 EXS SELECT SEQ SPEED / EXS140 EXS142 EXS120 & EXS140 SWITCHERS AND CONTROLS MAJOR OPERATG COMPONENTS (FRONT VIEW) {EXS125} (FRONT VIEW) {EXS145} P.B. DICATOR P.B. KEY AUTO/ALARM DICATOR AUTO KEY / KEYS / KEYS AUTO/ALARM DICATOR AUTO KEY P.B. DICATOR P.B. KEY / KEYS / KEYS SEQ./ALARM DICATORS 1-8 SEQ. SELECTOR KEYS 1-8 MANUAL DICATORS 1-8 ORS 1-8 AUTO SEQ SPEED / DICATOR SWITCH SEQ./ALARM DICATORS 1-4 SEQ. SELECTOR KEYS 1-4 MANUAL DICATORS 1-4 ORS SEQ SPEED / DICATOR SWITCH SEQ. CONTROL SPEED CONTROL ILIARY KEY SEQ. CONTROL SPEED CONTROL ILIARY KEY SEQUENTIAL / (REAR VIEW) {EXS125} (REAR VIEW) {EXS145} MANUAL MANUAL A/V &. SEQUENTIAL / MANUAL MANUAL A/V &. EXT. SYNC / EXT. SYNC ON-OFF SWITCH EXS EXT. SYNC / EXT. SYNC ON-OFF SWITCH ALARM 1-8 (FRONT VIEW) SEQ. A/V --REMOTE ALARM 1-4 SEQ. A/V --REMOTE (REAR VIEW) (FRONT VIEW) (REAR VIEW) SWITCHER EXS123 SWITCHER EXS143 {EXS123} {EXS143} SEQ SWITCHER EXS122 SWITCHER EXS142 {EXS122} {EXS142} SWITCHER EXS120 SWITCHER EXS140 {EXS120} Specifications and dimensions subject to change without notice. COMMON* SPECIFICATIONS ALARM ILIARY & CONTROLS Single level : 0.5V~2.0V p-p composite Input : Contact closure to ground Camera controls : Pan, tilt, zoom & focus via Input impedance : 75 (auto)/hi.z (manual) Inputs : 8/4 into 8 pin D cameras 8 pin D Camera inputs : 8/4 x BNC and 8 pin D Alarm output : Relay contacts closure (DC 24V/1A) Control s : +12V, ground or open(hi.z) Output level : 1.0V p-p composite through VCR 8 pin D Pan speed control : 3 /sec. ~ 11 /sec. (approx.) Output impedance : 75 (auto)/hi.z (manual) Alarm homing : Into 1st alarm or sequencing Auxiliary control : Tact switch contacts closure rated Monitor outputs : 1/2 x 8 pin D and multi alarms at 4 sec. intervals at 12V/30mA max. through manual 1/2 x BNC (EXS123-/125) monitor's 8 pin D input-output : 8 pin D and 2 x BNC Alarm holding : 60 sec. after alarm is cleared Aux. (on-off) line : +12V protected via 680 resistor video output : 1.0V p-p/75 Alarm reset : Automatic SWITCHER & EXT. SYNC GENERAL Input : 0.7V Video bandwidth : 8MHz 3dB (auto); Power supply : 100V, 120V, 220V, 240V AC50/60Hz Input impedance : 47 10MHz 3dB (manual) Power consumption : 10W Gain : 0dB Cross talk at 1KHz : Better than 60dB Cross talk at 5MHz : Better than 45dB Switching time : Less than 1.0 sec. Ambient temperature : 0 C ~ 50 C operating range Dimensions : 318 (W) x 67 (H) x 270 (D)mm (EXS120 series) Output impedance : 1K (auto)/hi.z (manual) Sequence time : 4 sec. ~ 45 sec. 221 (W) x 64 (H) x 243 (D)mm (EXS140 series) Inputs : 8/4 through camera 8 pin D Ext. sync. : +8V p-p via video coax cable Approx. weight : 2.2kg (EXS140 series); 3.5kg (EXS120 series) Outputs : Via A/V monitors & Ext. sync. rate : CCIR 25Hz; EIA 29.97Hz VCR 8 pin D to model selection chart for the incorporated number of channels, functions and features. {EXS140} OPTIONAL ACCESSORIES Alarm buzzer EBZ900 19" Rackmount kit ERM920 or ERM940 LTD. Elbex Bldg. 1-11, Nishi-Gotanda 8-Chome, Shinagawa-ku Tokyo , Japan Tel:(03) Fax:(03) ELBEX AMERICA C Noel Street, Los Alamitos, CA 90720, U.S.A. Tel:(714) /(800) FOR-CCTV, Fax:(714) NORTHWEST OFFICE: th Ave South Federal Way, WA Tel:(253) Fax:(253) ELBEX AMERICA (N.Y.) C. 300, Corporate Dr., Suite 5, Blauvelt, NY 10913, U.S.A. Tel:(845) /(800) Fax:(845) ELBEX (DEUTSCHLAND) GMBH Arzberger Str. 2, D Regensburg, Germany Tel:(0941) Fax:(0941) ELBEX (UK) PLC ELBEX House, Phoenix Business Park Avenue Road, Birmingham, B7 4NU, U.K. Tel:(121) Fax:(121) LONDON OFFICE: The Pavillions, Kiln Lane, Epsom, Surrey KT17 1JG Tel:(0137) Fax:(0137) ELBEX BENELUX N.V. Katwilgweg 11, 2050 Antwerpen, Belgium Tel:(03) Fax:(03) ELBEX NEDERLAND De Maas 13, 5684 PL Best, Holland Tel: Fax: ELBEX FRANCE 17 rue Casimir Perier, Bezons Cedex, France Tel: Fax: ELBEX LTD. (ISRAEL) 8, Kehilat Venezia St. Tel Aviv 69010, Israel Tel: Fax: ELBEX SCANDAVIA A/S Damhus Boulevard 98, DK-2610 Roedovre Denmark Tel:(36) Fax:(36) ELBEX SWEDEN Datavagen 6, S Askim, Sweden Tel:(031) Fax:(031) ELBEX (H.K.) LTD. ELBEX AUSTRALIA PTY. LTD. ELBEX SGAPORE PTE. LTD. Unit A, 1/F. On Fat Industrial Building, Kwai Wing Road, Kwai Chung, N.T., Hong Kong Tel: Fax: SYDNEY: Unit 15, Stubbs Street, Silverwater, NSW 2128, Australia Tel:(02) Fax:(02) MELBOURNE: Unit 2, 15, Shearson Crescent, Mentone, Vic. 3194, Australia Tel:(03) Fax:(03) BRISBANE: Unit 1, 121 Newmarket Street, Windsor, Qld. 4030, Australia Tel:(07) Fax:(07) Kampong Ampat #05-03, Junjie Industrial Bldg., Singapore Tel: Fax:

EverPlex 4BQ USER'S MANUAL. Real time B/W quad processor. High resolution picture quality. 4 Alarm input with buzzer

EverPlex 4BQ USER'S MANUAL. Real time B/W quad processor. High resolution picture quality. 4 Alarm input with buzzer EverPlex 4BQ USER'S MANUAL Real time B/W quad processor High resolution picture quality 4 Alarm input with buzzer Notice This manual is presented to the users of EverPlex 4BQ by EverFocus Electronics Corp.

More information

EverPlex 8BQ USER'S MANUAL. Real time B/W quad processor. Selectable single or dual quad display. High resolution picture quality

EverPlex 8BQ USER'S MANUAL. Real time B/W quad processor. Selectable single or dual quad display. High resolution picture quality EverPlex 8BQ USER'S MANUAL Real time B/W quad processor Selectable single or dual quad display High resolution picture quality 8 Alarm input with buzzer Table of Content Notice... 1 Safety Warning... 2

More information

VQCM4 Colour Quad Installation & Instruction Manual

VQCM4 Colour Quad Installation & Instruction Manual Thank you for purchasing our product. Please read this User s Manual before using the product. Change without Notice. VQCM4 Colour Quad Installation & Instruction Manual Table of Contents Safety Precautions...3

More information

.2 Section Waste Management and Disposal..4 Section Electrical General Requirements.

.2 Section Waste Management and Disposal..4 Section Electrical General Requirements. Issued 2005/06/01 Section 13704 Video Surveillance Page 1 of 10 PART 1 GENERAL 1.1 SECTION INCLUDES.1 Video cameras..2 Video handling..3 Recording devices..4 Transmission methods. 1.2 RELATED SECTIONS.1

More information

EVM4S/EVM4S+ The EIP4+ is an optional handset, in a matching design for extending the system to a kitchen or bedroom. White Pearl white Silver

EVM4S/EVM4S+ The EIP4+ is an optional handset, in a matching design for extending the system to a kitchen or bedroom. White Pearl white Silver 2 EVP4-4 COLOR VIDEO INTERPHONE STATION The EVP4 color video interphone system comes with alarms, emergencies, concierge system and much more. EVP4 SURFE MOUNTED COLOR SYSTEM MONITOR SIMPLE MAINTENANCE

More information

Matrix System150 Version 2.03

Matrix System150 Version 2.03 Matrix System150 Version 2.03 Matrix Switcher Controls up to 64 * cameras and 4 monitors. The Matrix System150 is compact, high in quality and cost effective. The new Panasonic Matrix System150 is ideal

More information

VPS3 Installation Manual

VPS3 Installation Manual 1-512-756-1678 VPS3 Installation Manual VPS3 Viewer (Local Unit) VPS3 Sender (Remote Unit) Content Introduction...2 Features...2 Packing Checklist...2 Patents...2 Limited Warranty...2 Overall Certificate...3

More information

Colour Observation System

Colour Observation System FAR < > NEAR Colour Observation system talk action menu _ + auto next FAR < > NEAR Colour Observation Monitor Colour Observation Monitor English Colour Observation System Table of contents Page Introduction...3

More information

System Controller WV-CU151. Before attempting to connect or operate this product, please read these instructions completely

System Controller WV-CU151. Before attempting to connect or operate this product, please read these instructions completely System Controller WV-CU5 Before attempting to connect or operate this product, please read these instructions completely CONTENTS PREFACE... FEATURES... PRECAUTIONS... MAJOR OPERATING CONTROL AND THEIR

More information

VDS2510 Installation Manual

VDS2510 Installation Manual Video Signal Output No. 1 C N.C Output VDS2510 Installation Manual C N.C Output Viewer 2510-L (Local Unit) Video Signal Output OUTPUT Connections There are two VIDEO OUT connectors. Please connect each

More information

Single Channel Video Receive Unit with two Bi-directional Data Channels and one Bi-directional Alarm Channel for a Multimode Fibre Link

Single Channel Video Receive Unit with two Bi-directional Data Channels and one Bi-directional Alarm Channel for a Multimode Fibre Link AMG5614A3 Instruction Manual Single Channel Video Receive Unit with two Bi-directional Data Channels and one Bi-directional Alarm Channel for a Multimode Fibre Link The AMG5614A3 is a standalone one channel

More information

USER'S MANUAL. Real Time Color Quad Processor. High Resolution, Broadcast Quality. Playback Zoom Function. RS232 Remote Control

USER'S MANUAL. Real Time Color Quad Processor. High Resolution, Broadcast Quality. Playback Zoom Function. RS232 Remote Control EverPlex 4CQ USER'S MANUAL EverPlex 4CQ + Freeze Seq NEXT P. DEFAULT Set Real Time Color Quad Processor High Resolution, Broadcast Quality Playback Zoom Function RS232 Remote Control Connect Up To 4 Cameras

More information

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS

TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS TECHNICAL MANUAL EDITION 1.0 VANDAL RESISTANT AUDIO AND VIDEO DOOR ENTRY SYSTEMS PAGE 2 of 24 AUDIO/VIDEO VANDAL RESISTANT TECHNICAL MANUAL VER1.0 CONTENTS PAGE Manual introduction 4 System introduction

More information

Videomatrix SIMATRIX 648

Videomatrix SIMATRIX 648 Videomatrix SIMATRIX 648 SIMATRIX 648 video matrix System characteristics Matrix unit Minimum configuration: 16/4 Maximum configuration: 64/8 Video inputs can be expanded in steps of 16, and video outputs

More information

Intelligent Security & Fire

Intelligent Security & Fire AV Disc Recorder WJ-DR200 ENGLISH FRANÇAIS Before attempting to connect or operate this product, please read these instructions carefully. ENGLISH VERSION PREFACE... 1 FEATURES... 1 PRECAUTIONS... 2 MAJOR

More information

9 camera. 16 camera. 9 camera. range. System Sprite video multiplex range and accessories. mono SYSTEM SX9 SYSTEM SX16 SYSTEM SX9C.

9 camera. 16 camera. 9 camera. range. System Sprite video multiplex range and accessories. mono SYSTEM SX9 SYSTEM SX16 SYSTEM SX9C. System Sprite video multiplex range and accessories range 9 camera mono colour mono colour simplex duplex optional remote keyboard 9 camera SYSTEM SX9 SYSTEM SX16 SYSTEM SX9C SYSTEM SX16C SYSTEM DX9 16

More information

CAUTIONS ON INSTALLATION

CAUTIONS ON INSTALLATION 2 CAUTIONS ON INSTALLATION 1) DO'S AND DON'T'S 2) Protection distance Do not install the unit at places where it may be interrupted by obstacles such as trees. Avoid strong light from the sun, automobile

More information

Part Number REV B. MV16i Multivision Plus Installation and Operation Manual

Part Number REV B. MV16i Multivision Plus Installation and Operation Manual Part Number 92-10088 REV B MV16i Multivision Plus Installation and Operation Manual MV16i Multivision Plus Notice Copyright The information in this manual was current when published. The manufacturer reserves

More information

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION 968 AFMS AFMS TECHNICAL SPECIFICATION 08/07 Ref B ATV-ELEKTRONIK GMBH WIENER STRASSE 228 A-4030 LINZ +43 732 301600 FAX. +43 732 301600 21 Page 2 Table of contents General Introduction...3 Overview...3

More information

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL A WIRELESS PASSIVE INFRARED DETECTOR AND THREE CHANNEL RECEIVER THAT SIMULTANEOUSLY OR INDIVIDUALLY CONTROLS CCTV SWITCHERS, VIDEO RECORDERS

More information

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623 MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623 PHONE 585-321-5800 FAX 585-321-5218 REVISIONS, IF ANY,

More information

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM Integrated Voice Evacuation System VM-3000 series Emergency Voice Alarm System Incorporating Digital Audio PA, Paging and BGM High-quality, compact public

More information

Dual System with 2x Independent Channels each of :

Dual System with 2x Independent Channels each of : AMG5723 Instruction Manual Dual System with 2x Independent Channels each of : [Single Transmit Unit with one Bi-directional Data Channel plus one Bi-directional Alarm for a Singlemode Fibre Link] The AMG5723

More information

MW9070B Optical Time Domain Reflectometer

MW9070B Optical Time Domain Reflectometer MW9070B Optical Time Domain Reflectometer Option 02 Monitoring Function Monitors Optical Fibers for Faults and Sends Alarm at Abnormality Automatic Fault Monitoring of Optical Fiber Cables More optical

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

PHOTOELECTRIC BEAM SENSOR PB- 50HFA-KH PB-100HFA-KH PB-200HFA-KH

PHOTOELECTRIC BEAM SENSOR PB- 50HFA-KH PB-100HFA-KH PB-200HFA-KH PHOTOELECIC BEAM SENSOR PB- 50HFA-KH PB-100HFA-KH PB-200HFA-KH PRODUCT DESCRIPTION 1 This product is a photoelectric beam sensor designed to be installed in a beam tower (sold separately). Please Note

More information

N-8000 SERIES IP INTERCOM SYSTEM

N-8000 SERIES IP INTERCOM SYSTEM N-8000 SERIES IP INTERCOM SYSTEM IP Network-Compatible Intercom System with Packet Audio Technology developed with cutting-edge TOA technological strengths for greater versatility and improved sound quality

More information

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts Emergency power automatics Type EPOMATIC MS-2, EC-2 4921240002D MS-2 EC-2 DEIF A/S All necessary functions: - mains supervision - start/supervision/stop of diesel engine - control of circuit breakers and

More information

SIMATRIX NEO Modular Video Matrix

SIMATRIX NEO Modular Video Matrix SIMATRIX NEO Modular Video Matrix SIMNEO-168 Modular Design Expandable up to 224 Video-Inputs, 32 Video-Outputs Up to 8 keyboards can be connected for control Multiple protocol driver for the direct control

More information

Alarm Tone Generator Model AG17

Alarm Tone Generator Model AG17 Alarm Tone Generator Installation & Operation P005089 Rev. C 150930 9/30/2015 12:25 PM Ph: 403.258.3100 \ email:info@guardiantelecom.com \ www.guardiantelecom.com Table of Contents Package Contents...

More information

Single Channel Video Transmit Unit with one Bi-directional Data Channel and two Uni-directional Alarms for a Multimode Fibre Link

Single Channel Video Transmit Unit with one Bi-directional Data Channel and two Uni-directional Alarms for a Multimode Fibre Link AMG5615 Instruction Manual Single Channel Video Transmit Unit with one Bi-directional Data Channel and two Uni-directional Alarms for a Multimode Fibre Link The AMG5615 is a compact standalone one channel

More information

APPLICATION NOTES. Stone Technologies Corporation Westrock Dr. #4 Austin, Texas OUT + + IN - + IN - + IN - + IN -

APPLICATION NOTES. Stone Technologies Corporation Westrock Dr. #4 Austin, Texas OUT + + IN - + IN - + IN - + IN - ISOFACE APPLICATION NO CUTS = 6V 12V 18V BOTH = 24V + - + - + - + - + - + - + - + - + - + - Stone Technologies Corporation 1-800-440-1234 2311 Westrock Dr. #4 Austin, Texas 78704 TWO WIRE LOOP FOR ED DEVICES

More information

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual RC802/804-240B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

SPEAKER SYSTEM SYSTÈME D ENCEINTES LAUTSPRECHERANLAGE OWNER S MANUAL MODE D EMPLOI BEDIENUNGSANLEITUNG

SPEAKER SYSTEM SYSTÈME D ENCEINTES LAUTSPRECHERANLAGE OWNER S MANUAL MODE D EMPLOI BEDIENUNGSANLEITUNG GT NS-300 NS-200 SPEAKER SYSTEM SYSTÈME D ENCEINTES LAUTSPRECHERANLAGE OWNER S MANUAL MODE D EMPLOI BEDIENUNGSANLEITUNG Thank you for selecting this YAMAHA NS-300/NS-200 speaker system. PRECAUTIONS Read

More information

Model AD2150 Video Matrix Switcher/Controller System

Model AD2150 Video Matrix Switcher/Controller System Model AD2150 Video Matrix Switcher/Controller System Installation and Operation Instructions This manual describes the installation and operating procedures for the American Dynamics model AD2150 Video

More information

Model AD C AD RS-422 Distributor

Model AD C AD RS-422 Distributor Model C AD RS-422 Distributor Installation and Operation Instructions Speed LT, Speed, Speed Ultra, Speed Optima, and Speed Optima LT The C Distributor is used to interface American Dynamics Switching

More information

VIDEO CONTROLS LIMITED

VIDEO CONTROLS LIMITED VIDEO CONTROLS LIMITED MAXCOM PRO SERIES TELEMETRY CONTROL SYSTEMS Operation Guide for use with MaxCom 3V, MaxCom 3VE, MaxCom 4V and MaxCom4VE Document Code number - CI431V2 Table of Contents Safety Instructions

More information

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual Technical Manual Type EC-2 Engine Control Unit 4189340232D DEIF A/S Technical Manual DEIF A/S Tel.: (+45) 9614 9614 Frisenborgvej 33, DK-7800 Skive Fax: (+45) 9614 9615 Denmark E-mail: deif@deif.com Contents

More information

PUBLIC ADDRESS SYSTEM

PUBLIC ADDRESS SYSTEM EUROPE & USA Norden Communication UK Ltd 20-22 Wenlock Road London N17GU United Kingdom Tel: +44 [0] 2077887663 Fax: +44 [0] 2032921987 E-mail: sales@nordencommunication.com ASIA A Norden Communication

More information

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5

VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5 Page 1 of 5 No entry if additional Model Code / Additional Spec. Code ( spec. code is not specified. ) VM-702B /ALY /NB1 /CS1 /CS2 /TRP /TB Analysis Function Non-incendive * 1 Monitor Function Analysis

More information

SMALL SCALE SOLUTIONS

SMALL SCALE SOLUTIONS SMALL SCALE SOLUTIONS THE FIREWARDEN SERIES STATE-OF-THE-ART SIMPLICITY NOTIFIER s FireWarden 50 and 100-2 intelligent fire alarm control systems are perfect for facilities requiring simple, yet, state-of-the-art

More information

Printed on recycled paper Copyright reserved Subject to modification Colour Observation Quad

Printed on recycled paper Copyright reserved Subject to modification Colour Observation Quad Printed on recycled paper Copyright reserved Subject to modification 3122 165 21323 Colour Observation Quad Important notes for users in the U.K. Warning: to prevent fire or shock hazard, do not expose

More information

Dräger QuadGard Control System

Dräger QuadGard Control System Dräger QuadGard Control System The Dräger QuadGard is a standalone, self contained control system for the detection of Toxic, Oxygen and Ex hazards The system can be configured for up to four independent

More information

MD12-2 Vehicle Loop Detector

MD12-2 Vehicle Loop Detector MD12-2 Vehicle Loop Detector Features Supply 12VDC Adjustable sensitivity (8 levels via dip switch) 2 x Relay outputs (each can be configured individually) Power up and loop activation LED indicator. Industry

More information

Four channel video link For low cost video transmission

Four channel video link For low cost video transmission User Manual Four channel video link For low cost video transmission CFO First Mile series consist of fi bre optic modems which provide a high quality and losless video transmission for variety of CCTV

More information

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL GS100-ATEX Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL The GS100 beam set is a detection device only, and is designed to be used in

More information

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus LD-64 Profibus INSTALLATISANVISNING INSTALLATI MANUAL INSTALLATIS ANLEITUNG Galvanic Isolation 6073-2031 Transient Protection Balanced Transmission CE Approved Westermo Teleindustri AB 2001 REV. B Fiberoptiskt

More information

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL GS100-ATEX Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL The GS100 beam set is a detection device only, and is designed to be used in

More information

IWAKI HI-CERA PUMPS V

IWAKI HI-CERA PUMPS V IWAKI HI-CERA PUMPS Ultra-high precision valveless plunger pump Fine ceramic plunger highly resistant to corrosion and abrasion Ultra-high precision mechanism Drive joint Pin Special bearing Plunger Pumping

More information

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504 Remote Monitor PTE0700 SECURITY ELECTRONICS User Manual PTE0700 V2 Series Remote Monitor Pakton Technologies Pty Ltd ABN 66 405 694 842 16 Ferrier Road, Narangba Qld 4504 PO Box 408, Narangba QLD 4504

More information

6 5 0 E X WJ-SX650 WJ-SX650U

6 5 0 E X WJ-SX650 WJ-SX650U Matrix System50EX Matrix System 50EX. Enhancg Large-System Surveillance. cameras and 4 monitors, plus up to 4-doma Satellite capability The new Panasonic Matrix System50EX redefes "advanced" large-system

More information

USER MANUAL. Tavor 5-O (SPK-WA511) On-Wall Active Speakers MODEL: P/N: Rev 4

USER MANUAL. Tavor 5-O (SPK-WA511) On-Wall Active Speakers MODEL: P/N: Rev 4 KRAMER ELECTRONICS LTD. USER MANUAL MODEL: Tavor 5-O (SPK-WA511) On-Wall Active Speakers P/N: 2900-300366 Rev 4 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Recycling

More information

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005) RC801/803/805-480B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,

More information

USER MANUAL. Galil 8-C Closed-back Ceiling Speakers MODEL: P/N: Rev 2

USER MANUAL. Galil 8-C Closed-back Ceiling Speakers MODEL: P/N: Rev 2 KRAMER ELECTRONICS LTD. USER MANUAL MODEL: Galil 8-C Closed-back Ceiling Speakers P/N: 2900-300345 Rev 2 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Recycling

More information

Intrusion Outdoor Protection Perimeter

Intrusion Outdoor Protection Perimeter Intrusion Outdoor Protection Perimeter Borders Commercial industrial Military base Correctional institution VIP Estates/Residences Communication Airports Warehouses Perimeter Sensors: the ideal solution

More information

14 B&W OBSERVATION SYSTEM MODEL: HD14S1042-A

14 B&W OBSERVATION SYSTEM MODEL: HD14S1042-A 14 B&W OBSERVATION SYSTEM MODEL: HD14S1042-A FOR MORE INFORMATION WWW.STRATEGICVISTA.COM/ADT Before operating this system, please read this Manual thoroughly and retain it for future reference!!! Thank

More information

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008 TCD Telemetry Communications Device Installation Guide Interface for the Emizon managed network Issue 1: February 2008 This guide sets out a simple check list together with a step-by-step guide to the

More information

VMD-2008 Operation Manual

VMD-2008 Operation Manual Operation Manual CORPORATION Digi-Spec Corporation 16118 Runnymede Street Van Nuys, CA 91406 CORPORATION A new way of looking at things... RAC011192 Operation Manual Digital Video Motion Detector Version

More information

21-light Remote Annunciator. Owner s Manual

21-light Remote Annunciator. Owner s Manual 21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With

More information

Dräger VVP 1000 System Components

Dräger VVP 1000 System Components Dräger VVP 1000 System Components The Dräger VVP 1000 is a 10" touch panel that provides a clear and simple display of all data from your Dräger VarioGard gas detector. The touch panel visualises all relevant

More information

System-X offers a variety of alarm interfaces suitable for different applications. The possibilities are:

System-X offers a variety of alarm interfaces suitable for different applications. The possibilities are: System-X offers a variety of alarm interfaces suitable for different applications. The possibilities are: Product I141DX I121DX I151SX-ALARM Description Alarm interface with 8 alarm inputs and 8 AUX outputs,

More information

Intercom Systems Video Intercoms

Intercom Systems Video Intercoms 8.0 International Offices CHINA Clipsal China Ltd Tel: +86 755 8237 5577 Fax: +86 755 8237 5576 sales@c-bus.com.cn GEORGIA Clipsal Contact Tel: +995 32 65 5599 Fax: +995 32 65 6699 clipsalcontact@gol.ge

More information

OPERATION MANUAL MODEL & ACCELEROMETER

OPERATION MANUAL MODEL & ACCELEROMETER OPERATION MANUAL MODEL 8011-01 & 8021-01 ACCELEROMETER TE CONNECTIVITY SENSORS///MODEL 8011-01 & 8021-01 ACCELEROMETER 05/2016 Page 1 WARRANTY Measurement Specialties, Inc. accelerometers are warranted

More information

Instruction Manual. Digital Recorder. Model SDR-304. Make sure all the accessories are supplied together. Introduction Connection. Operation.

Instruction Manual. Digital Recorder. Model SDR-304. Make sure all the accessories are supplied together. Introduction Connection. Operation. Digital Recorder Instruction Manual Model SDR-304 Function r - ACCESS ALARM REMOTE WARNING TIMER MENU ENTER SHIFT Setting Others Make sure all the accessories are supplied together. AC120V NTSC CAUTION

More information

USER MANUAL. Tavor 6-O On-Wall Active Speakers MODEL: P/N: Rev 1.

USER MANUAL. Tavor 6-O On-Wall Active Speakers MODEL: P/N: Rev 1. USER MANUAL MODEL: Tavor 6-O On-Wall Active Speakers P/N: 2900-300516 Rev 1 www.kramerav.com Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Recycling Kramer Products

More information

3 T828 Initial Adjustment

3 T828 Initial Adjustment M820-00 T828 Initial Adjustment D3.1 3 T828 Initial Adjustment Caution: This equipment contains CMOS devices which are susceptible to damage from static charges. Refer to Section 1.2 in Part A for more

More information

PRECAUTIONS WHEN POSITIONING

PRECAUTIONS WHEN POSITIONING English OWNER S MANUAL NS-8HX Speaker System G R Thank you for selecting this YAMAHA NS-8HX speaker system. PRECAUTIONS Read this before using the speakers. To assure the finest performance, please read

More information

VACIE REFERENCE GUIDE REVISION 1.2.6

VACIE REFERENCE GUIDE REVISION 1.2.6 VACIE REFERENCE GUIDE REVISION 1.2.6 November 2016 INTRODUCTION... 3 SECTION 1... 4 VACIE CONFIGURATION... 4 Communications... 4 Vocia VACIE Devices... 4 Vocia Support devices:... 5 Power Supply and Network

More information

Dräger Flame 5000 Flame Detection

Dräger Flame 5000 Flame Detection Dräger Flame 5000 Flame Detection The Dräger Flame 5000 is an imaging based explosion proof flame detector This visual flame detection system uses digital image processing and advanced algorithms to process

More information

Line Isolation Monitor (LIM) LIM2000plus

Line Isolation Monitor (LIM) LIM2000plus Line Isolation Monitor (LIM) LIM2000plus for Single and Three Phase Systems TDB207005usa/10.2008 BENDER Group Line Isolation Monitor LIM2000plus for Single and Three Phase Systems LIM2000plus Device features

More information

ADDENDUM. xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION GENERAL APPLICATION INFORMATION

ADDENDUM. xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION GENERAL APPLICATION INFORMATION ADDENDUM xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION The xwatch Explosion-Proof Camera is available as a factory installed option with any of the Det Tronics X Series line of

More information

Call stations and extensions

Call stations and extensions Novigo Call stations and extensions PT2001-A1, PT2002-A1, PT2008-A1, PT2009-A1, PTO2001-A1, PTO2002-A1, PTO2003-A1, PTO2004-A1, PTO2005-A1, PTO2006-A1, PTO2008-A1 EN 54-16-certified alarm and business

More information

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS DCA4 Digitally controlled Audio Matrix Product Specification March 2002 Current Thinking Document Number DDC DCA 7001 01 ACS Introduction Voice Alarm (VA) systems are the quickest way to evacuate the public

More information

Return loss measurement of fiber optic components

Return loss measurement of fiber optic components Return loss measurement of fiber optic components Solutions Brief 815-1 How the HP 8153A/HP 81534A measure return loss of fiber optic components? The significance of return loss The introduction of new

More information

RVRC Training Manual Fast Trace Installer Menu

RVRC Training Manual Fast Trace Installer Menu RVRC Training Manual Fast Trace Installer Menu Advanced Independent Monitoring Introduction The following guide is explain how to set up a Fast Trace or Fast TX and common areas to look out for and check

More information

OPERATION / INSTALLATION

OPERATION / INSTALLATION OPERATION / INSTALLATION & PROGRAMMING MANUAL AFP-2800 LCD-80 Fire Alarm Panel Revision 1.01 November 16, 2004 NSW (Head Office) 7 Columbia Court Norwest Business Park Baulkham Hills NSW 2153 Ph: (02)

More information

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data Elite GJD022 /GJD023 35m External PIR Multi Beam Lens Data The GJD multifunction lens fitted to the GJD Elite detector produces 9 long range beams and 9 medium to short range curtain beams. Movement across

More information

1.6. Installation instructions for Bridge Navigation Watch Alarm System (BNWAS 3000)

1.6. Installation instructions for Bridge Navigation Watch Alarm System (BNWAS 3000) Technical Documentation BNWAS 000.. Installation instructions for Brid Navigation Watch Alarm System (BNWAS 000) WATCH ALARM MAIN UNIT REATER UNIT SELECTOR UNIT RESET UNIT Revisions Version Date Author

More information

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933 Two-hand Safety Control Module FF-SR Series FEATURES Complies with the Machinery Directive 98/37/EC and UL 508 Type III C per EN 574, Category 4 per EN 954-1 Inputs for two dual-contact pushbuttons 0,5

More information

Movement Detector GJD 300

Movement Detector GJD 300 Movement Detector GJD 300 Installation & Set Up Guide Introduction A CCTV event trigger utilising two independent passive infrared detectors combined in a T05 package. Both sensors have to trigger before

More information

WH EN IGH T T C LO SED

WH EN IGH T T C LO SED AR EA kajdfkjl; lkjdflkjal; ldkfj;alk alskjdf ;lsdkf 7079 ph/orp Transmitter 70-82-03-08 1/97 Page 1 of 5 Specification Overview The 7079 ph/orp Transmitter is designed for chemical process industry applications

More information

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System DIVA8MG2 Public Address - Voice Alarm Audio Distribution over IP Commercial Audio Intelligent Acoustic Solutions Intercommunication Loudspeakers Compact PAVA System Master Unit DIVA8 System DIVA8 system

More information

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET Instruction Manual Model 1582-125L 1:1 Switch February 2017, Rev. 0 CH1 HISTORY LINE HISTORY RESET AUTO MANUAL SELECT CH2 HISTORY LINE RESET MANUAL REMOTE AUTO PS1 PS2 MODEL 1582 CROSS TECHNOLOGIES INC.

More information

Installation and ZONES: Operation Manual. Model: ON STI-34108

Installation and ZONES: Operation Manual. Model: ON STI-34108 N.O. COM N.C. + 12 V - IN + 12 V - OUT 500 ma 300 ma PLUG IN ADAPTER 12 V 500mA Trigger Output 12 V 75mA N.O. COM N.C. + 12 V - IN + 12 V - OUT 500 ma 300 ma PLUG IN ADAPTER 12 V 500mA Trigger Output 12

More information

Pyroelectric Infrared PIR Motion Sensor Detector ADJ User s Guide

Pyroelectric Infrared PIR Motion Sensor Detector ADJ User s Guide Pyroelectric Infrared PIR Motion Sensor Detector ADJ User s Guide 2004-2009 Sure Electronics Inc. DC-SS502_Ver1.0 Table of Contents Chapter 1. Overview...1 1.1 Preface... 1 1.2 Functions... 1 Chapter 2.

More information

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer Product Brochure & Data Sheet Headquarters: Phoenix, Arizona 20100, N 51st Ave, Suite

More information

USER MANUAL. Tavor 8-Sub Powered Subwoofer MODEL: P/N: Rev 4

USER MANUAL. Tavor 8-Sub Powered Subwoofer MODEL: P/N: Rev 4 KRAMER ELECTRONICS LTD. USER MANUAL MODEL: Tavor 8-Sub Powered Subwoofer P/N: 2900-300397 Rev 4 Contents 1 Introduction 2 2 Getting Started 3 2.1 Achieving the Best Performance 3 2.2 Recycling Kramer

More information

EVID FM-Series Loudspeaker User Manual

EVID FM-Series Loudspeaker User Manual EVID FM-Series Loudspeaker User Manual Table of Contents Table of Contents...2 Welcome...3 Important Features...3 Model Summary...4 Packing List...6 Product Feature Identification...7 Installation and

More information

DOLKPS1KB Programming & Installation Manual

DOLKPS1KB Programming & Installation Manual VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD WITH WIEGAND OUTPUT & DATA I/O DOLKPS1KB Programming & Installation Manual FOR ELECTRIC LOCK, INTER-LOCK AND SECURITY SYSTEM INSTALLATIONS DOLKPS1KB

More information

STT 3000 Series STT250 /150 Surge Protection Device Specifications

STT 3000 Series STT250 /150 Surge Protection Device Specifications STT 3000 Series STT250 /150 Surge Protection Device Specifications Part Number: 46188660-501 EN2I-6061 June 2011 Introduction This device is designed to give the Smart Temperature Transmitter maximum protection

More information

The First Name in Digital Audio. A/V Amplifier

The First Name in Digital Audio. A/V Amplifier The First Name in Digital Audio A/V Amplifier A/V Amplifier The World's First A/V Amplifier with THX Surround EX Denon s tradition of excellence and innovation in audio and home theater continues with

More information

Dräger Polytron 8310 Stationary gas detector (DSIR)

Dräger Polytron 8310 Stationary gas detector (DSIR) Stationary gas detector (DSIR) SIMPLE INSTRUMENT MANAGEMENT POISON-RESISTANT AND FAIL-SAFE THANKS TO DIGITAL COMMUNICATION The DrägerSensor IR offers several benefits: technological advantages such as

More information

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: Yarden 5-O On-Wall Speakers. P/N: Rev 3

KRAMER ELECTRONICS LTD. USER MANUAL MODEL: Yarden 5-O On-Wall Speakers. P/N: Rev 3 KRAMER ELECTRONICS LTD. USER MANUAL MODEL: Yarden 5-O On-Wall Speakers P/N: 2900-300352 Rev 3 Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Recycling Kramer Products

More information

IF-L/RF Protection Switch

IF-L/RF Protection Switch Instruction Manual Model 1582-1152 IF-L/RF Protection Switch August 2014, Rev. 0 CH1 HISTORY ALARM LINE HISTORY RESET AUTO MANUAL SELECT CH2 HISTORY ALARM LINE RESET MANUAL REMOTE AUTO ALARM PS1 PS2 MODEL

More information

WM3000 WIRELESS MODULES

WM3000 WIRELESS MODULES WM3000 WIRELESS MODULES $$:05 $$:07 INSTALLATION INSTRUCTIONS Table of Contents Installation... 3 Mounting Instructions & Connections... 3 Setting the Dip Switches... 4 Setting the Recognition Time...

More information

MTL1000 Series Signal Conditioners. For reliable, high quality process communications

MTL1000 Series Signal Conditioners. For reliable, high quality process communications MTL1000 Series Signal Conditioners For reliable, high quality process communications The new MTL1000 Series of signal conditioning isolators complement our Intrinsic Safety products to provide a complete

More information

DOLKPL1KB DOLKPS1KB DOLKSF1KB

DOLKPL1KB DOLKPS1KB DOLKSF1KB DOLKPL1KB DOLKPS1KB DOLKSF1KB USER MANUAL INSTRUCTIONAL VIDEO 1] Connection Terminals 2] Basic Wiring Example 3] Quick Start Guide 4] Programming Guide 5] Specifications 1 Connection Terminals The DOLKPS1KB/DOLKPS1KB/DOLKSF1KB

More information

MTL1000 range of signal conditioners. For reliable, high quality process communications

MTL1000 range of signal conditioners. For reliable, high quality process communications MTL1000 range of signal conditioners For reliable, high quality process communications The new MTL1000 range of signal conditioning isolators complement our intrinsic safety products to provide a complete

More information

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001 ISO-14001 ISO-9001 SPECIFICATION SHEET ORGANIC POLLUTION MONITOR Model: OPM-410A The Model OPM-410A monitors organic pollution in water from industrial effluent, rivers etc.. The design and construction

More information

Technical Manual. Level Alarm Unit CARLA & WIDS

Technical Manual. Level Alarm Unit CARLA & WIDS CARLA & WIDS Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CARLA for Tankers Cargo Tanks

More information