1.6. Installation instructions for Bridge Navigation Watch Alarm System (BNWAS 3000)
|
|
- Ada Townsend
- 5 years ago
- Views:
Transcription
1 Technical Documentation BNWAS Installation instructions for Brid Navigation Watch Alarm System (BNWAS 000) WATCH ALARM MAIN UNIT REATER UNIT SELECTOR UNIT RESET UNIT Revisions Version Date Author Checked Remark.0 0/0/ JB TM Derived from draft 0. Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa of
2 Technical Documentation BNWAS 000 Table of contents. General.... Cable requirements.... Connection of the various units.... Setting the address (REATER UNIT) Accumulator charging Pin assiments WATCH ALARM MAIN UNIT REATER UNIT..... SELECTOR UNIT..... RESET UNIT..... BOOSTER UNIT Current Accumulator Installation Audible sial nerator Reset sensor Location Compass safe distance Commissioning... Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa of
3 Technical Documentation BNWAS 000. General These installation instructions supplement the documentation of the BNWAS (system description, operating instructions, technical documentation...). For further information, see the relevant documentation. The currently applicable standards must be consulted prior to installation of the BNWAS and observed.. Cable requirements For safe operation of the entire system, the cables shown in the table are recommended. Connector Cable type Core diameter Cable diameter Power supply 00-0 Unshielded cable min. x. mm² V AC (JM) Power supply V DC Unshielded cable min. x. mm² (JM) Accumulator V Shielded cable x. mm² (JB) REATER UNIT Shielded twisted-pair cable x x 0.7 mm² (JR, JR) RESET UNIT (JQ) Shielded twisted-pair cable min. x x 0.7 mm² -0mm SERIAL OUT (JV) Shielded twisted-pair cable x 0.7 mm² SERIAL OUT (JV) Shielded standard serial cable SERIAL IN (JG) Shielded twisted-pair cable x 0.7 mm² SERIAL IN (JA) Shielded twisted-pair cable x 0.7 mm² RESET SENSOR Unshielded cable min. x 0.7 mm² (JE) Relay output (JK) Unshielded cable min. 9 x.0 mm² AUTO MODE ON/OFF; ext. sial nerator (JPI) Unshielded cable x 0.7 mm² Cable diameter depends on cable length and number of UNITS. Cable diameter depends on current and volta. Cable diameter depends on connected siren, current and volta. Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa of
4 Technical Documentation BNWAS 000. Connection of the various units /0 - V mains-control Accu-control V - V RTC RS8 RS8 x out-control In ext. reset REATER UNIT SERIAL OUT / SERIAL IN RESET SENSOR RESET UNIT Power supply 00-0 V AC Power supply V DC Accumulator V JM JM JB WACHT ALARM MAIN UNIT BNWAS000 M U-E V - V Beeper DECKMA GMBH Status-LED Mikrocontro ller Mikrocontroller V - V Auto on/off Ext. Beeper V - V V - V V - V V - V RS8 RS8 JR JV JR JV JP JG JA JE JK JQ WATCH ALARM MAIN UNIT AUTO MODE ON/OFF; ext. Sial nerator WATCH ALARM MAIN UNIT SERIAL IN Power supply V DC REATER UNITS WATCH ALARM MAIN UNIT Relay output WATCH ALARM MAIN UNIT REATER UNIT BNWAS000 RPU-E DECKMA GMBH JR DECKMA GMBH JR JM JQ DECKMA GMBH RESET UNIT JQ BOOSTER UNIT BNW AS000 BU-E JR Beeper V - V JR JR Mikrocontroller RS8 JR SELECTOR UNIT BNWAS000 SU-E BNWAS000 RSU-E RESET UNITS JQ0 Power supply V DC JM Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa of
5 Technical Documentation BNWAS 000 Wiring diagram BNWAS 000 without SELECTOR UNIT SERIAL RS8-A RS8-B JV SERIAL OUT SERIAL TXD RXD 7 8 JV 9 SERIAL OUT PC, VDR, Gerneralalarm... V DC power supply rt sw gr/ V in JM Power supply V DC Netz bl gr/ N in L in JM Power supply 00-0 V AC Akku V V 7Ah V 7Ah ,A rt sw BP BM SC A SC B R JB Accumulator V General alarm, Sial nerator... K NO K CM K NC K NO K CM K NC K NO K CM K NC JK Relay output Time/date in, Reset, Emerncy Alarm Via RS or RS8 RXD TXD RS8-A RS8-B JG SERIAL IN Time/date in, Reset, Emerncy Alarm Via RS or RS8 RXD TXD RS8-A RS8-B JA SERIAL IN Überarbeitet MP / 0.0. Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa of
6 Technical Documentation BNWAS 000 V in LED in RESET out optional JQ JQ0 MU RSU V out LED out RESET in V in LED in RESET out JQ MU RESET UNIT 0x max BOOSTER UNIT JM Power supply V DC V ext. JQ RESET UNIT V out LED out RESET in V in LED in RESET out JQ MU RESET UNIT x max RS8-A RS8-B V in ADR 0 ADR AS WAP 7 8 REATER UNIT WATCH ALARM MAIN UNIT JR JR REATER UNIT RS8-A RS8-B V out RS8-A RS8-B V in ADR 0 ADR AS WAP 7 8 REATER UNIT WATCH ALARM MAIN UNIT JPI AUTO MODE ON/OFF; ext. Sial nerator V out SIGNAL out AUTO in V PZ Sial RS8-A RS8-B V in ADR 0 ADR AS WAP 7 8 REATER UNIT WATCH ALARM MAIN UNIT RS8-A RS8-B V in ADR 0 ADR AS WAP 7 8 REATER UNIT WATCH ALARM MAIN UNIT JE RESET SENSOR SABOT in RESET in V out Sabota Reset Sensorik Reset Reset Sensorik WATCH ALARM MAIN UNIT Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa of
7 Technical Documentation BNWAS 000 Wiring diagram BNWAS 000 with SELECTOR UNIT SERIAL RS8-A RS8-B JV SERIAL OUT SERIAL TXD RXD 7 8 JV 9 SERIAL OUT PC, VDR, Gerneral alarm... V DC power supply rt sw gr/ V in JM Power supply V DC Netz bl gr/ N in L in JM Power supply 00-0 V AC Akku V V 7Ah V 7Ah ,A rt sw BP BM SC A SC B R JB Accumulator V General alarm, Sial nerator... K NO K CM K NC K NO K CM K NC K NO K CM K NC JK Relay output Time/date in, Reset, Emerncy Alarm Via RS or RS8 RXD TXD RS8-A RS8-B JG SERIAL IN Time/date in, Reset, Emerncy Alarm Via RS or RS8 RXD TXD RS8-A RS8-B JA SERIAL IN Überarbeitet MP / 0.0. Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa 7 of
8 Technical Documentation BNWAS 000 V in LED in RESET out optional JQ JQ0 MU RSU V out LED out RESET in V in LED in RESET out JQ MU RESET UNIT 0x max BOOSTER UNIT JM Power supply V DC V ext. JQ RESET UNIT V out LED out RESET in V in LED in RESET out JQ MU RESET UNIT x max optional RS8-A RS8-B V in ADR 0 ADR 7 AS WAP 8 REATER UNIT WATCH ALARM MAIN UNIT JR JR REATER UNIT RS8-A RS8-B V out RS8-A RS8-B V in JR WATCH ALARM MAIN UNIT JR RPU JR RPU RS8-A RS8-B V out RS8-A RS8-B V out RS8-A RS8-B V in ADR 0 ADR 7 AS WAP 8 REATER UNIT WATCH ALARM MAIN UNIT JPI AUTO MODE ON/OFF; ext. Sial nerator V out SIGNAL out AUTO in V PZ Sial V in optional power supply JM Power supply V DC JR RPU JR RPU RS8-A RS8-B V out RS8-A RS8-B V out RS8-A RS8-B V in ADR 0 ADR 7 AS WAP 8 REATER UNIT WATCH ALARM MAIN UNIT JE RESET SENSOR SABOT in RESET in V out Sabota Reset Sensorik Reset Reset Sensorik SELECTOR UNIT max. ciruits each with maximum Repeater Units RS8-A RS8-B V in ADR 0 ADR 7 AS WAP 8 REATER UNIT WATCH ALARM MAIN UNIT WATCH ALARM MAIN UNIT Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa 8 of
9 Technical Documentation BNWAS 000. Setting the address (REATER UNIT) The REATER UNIT functions as a slave within a bus system from where it receives all system relevant data. Since up to four REATER UNITS can be connected to the BNWAS, each UNIT requires its own address on the bus. The address can be set by connecting Pins and/or 7 of connector JR to ground. Pin Pin 7 Address - - Gnd - - Gnd Gnd Gnd If the system is only configured for one REATER UNIT, only address must be used. If the system has been configured for two UNITS, address must be added for three UNITS, and for the maximum number (four),. If the address no lonr corresponds to the system configuration, an error is nerated.. Accumulator charging The accumulator is chard via current control. The current can be adjusted with a resistor connected between PINS and on the V accumulator connector (JB). Resistor 0-00 Ω 00 ma KΩ 0 ma.00 - KΩ 00 ma No resistor open 0 ma Current. Pin assiments.. WATCH ALARM MAIN UNIT Pin assiments Power supply V DC -pin Weidmüller RM.08 JM V in Power supply V DC in Shield Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa 9 of
10 Technical Documentation BNWAS 000 Pin assiments Power supply 00-0 V AC -pin Phoenix RM.08 JM N in V AC L in Neutral Shield Pin assiments Accumulator V -pin Weidmüller RM.08 JB BP V BM SC A Charging current selection SC B Charging current selection Shield Charging current selection Resistor Charging current Suitable for accumulators 0R max. 00 ma > A/h k max. 0 ma >. A/h k max. 00 ma > A/h None max. 0 ma > 00 ma/h Pin assiments RESET UNIT -pin Weidmüller RM.08 JQ V out Power supply V out LED out LED ightness/on/off RESET in Reset Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa 0 of
11 Technical Documentation BNWAS 000 Pin assiments REATER UNIT -pin Weidmüller RM. JR JR Shield RS8-A RS8-A connection to REATER UNIT RS8-B RS8-B connection to REATER UNIT V out Power supply V out Pin assiments AUTO MODE ON/OFF; -pin Phoenix RM.08 JPI External sial nerator V out Power supply V for sial nerator SIGNAL out External sial nerator NC Not connection AUTO in AUTO MODE ON/OFF Pin assiments SERIAL OUT -pin Weidmüller RM. JV RS8-A RS8-A event and alarm out RS8-B RS8-B event and alarm out Shield Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa of
12 Technical Documentation BNWAS 000 Pin assiments SERIAL OUT 9-pin Sub-D female connector JV TXD RS TxD service out RXD RS RxD service out Pin assiments SERIAL IN -pin Weidmüller RM. JG Shield RXD RS RxD serial reset/time and date in TXD RS TxD serial reset/time and date in RS8-A RS8-A serial reset/time and date in RS8-B RS8-B serial reset/time and date in Pin assiments SERIAL IN -pin Weidmüller RM. JA Shield RXD RS RxD serial reset/time and date in TXD RS TxD serial reset/time and date in RS8-A RS8-A serial reset/time and date in RS8-B RS8-B serial reset/time and date in Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa of
13 Technical Documentation BNWAS 000 Pin assiments RESET SENSOR -pin Phoenix RM.08 JE SABOT in Sabota RESET in Reset sensor V out Power supply reset sensor V (max. 00 ma) Pin assiments Relay output 9-pin Weidmüller RM. JK K NO. Alarm relay Normally Open K CM. Alarm relay Com K NC. Alarm relay Normally Closed K NO. Alarm relay Normally Open K CM. Alarm relay Com K NC. Alarm relay Normally Closed 7 K NO Fault relay Normally Open 8 K CM Fault relay Com 9 K NC Fault relay Normally Closed Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa of
14 Technical Documentation BNWAS REATER UNIT Pin assiments WATCH ALARM MAIN UNIT -pin Weidmüller RM. JR Shield RS8-A RS8-A connection to WATCH ALARM MAIN UNIT RS8-B RS8-B connection to WATCH ALARM MAIN UNIT V in Power supply V in ADR 0 Address 0 7 ADR Address 8 N.C. N.C. Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa of
15 Technical Documentation BNWAS SELECTOR UNIT Pin assiments Power supply V DC -pin Weidmüller RM.08 JM V in Power supply V (optional) Shield Pin assiments WATCH ALARM MAIN UNIT -pin Weidmüller RM. JR Shield RS8-A in RS8-A connection to REATER UNIT in RS8-B in RS8-B connection to REATER UNIT in V in Power supply V in Pin assiments REATER UNIT -pin Weidmüller RM. JR...JR Shield RS8-A out RS8-A connection to REATER UNIT out RS8-B out RS8-B connection to REATER UNIT out V out Power supply V out Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa of
16 Technical Documentation BNWAS RESET UNIT Pin assiments Watch ALARM MAIN UNIT -pin Weidmüller RM. JQ V in Power supply V LED in LED ightness/on/off RESET out Reset Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa of
17 Technical Documentation BNWAS BOOSTER UNIT Pin assiments Power supply V DC -pin Weidmüller RM.08 JM V ext. Power supply V external Pin assiments WATCH ALARM MAIN UNIT -pin Weidmüller RM. JQ V int. Power supply V internal LED in LED ightness/on/off RESET out Reset Pin assiments RESET UNIT -pin Weidmüller RM.08 JQ0 V out Power supply V out LED out LED ightness/on/off RESET in Reset Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa 7 of
18 Technical Documentation BNWAS Current The WATCH ALARM MAIN UNIT supplies the BNWAS (entire system with all associated UNITS) with power. For this reason, the BNWAS must be configured so that the maximum current of the WATCH ALARM MAIN UNIT is not exceeded. Note: Several UNITS can be connected to their own power source and supply other UNITS with power. An EXCEL table for precise calculation of the system configuration is available (Consumption BNWAS xxxxx.xls). 8. Accumulator The accumulator must be dimensioned to supply the BNWAS with power for at least hours. 9. Installation All WATCH ALARM MAIN UNITS, REATER UNIT and SELECTOR UNIT must be installed in a mounting panel (dimensions for cutouts: width = 7 mm, height = mm). The BOOSTER UNIT must be mounted on a top-hat rail in a panel or control cabinet. The RESET UNIT (open frame) must be panel or wall mounted and protected against manipulation with special scre. The RESET UNIT (watertight) must be panel or wall mounted and protected against manipulation with special scre. It should be noted that connectors, cables and housing openings are not accessible and the system is tamper-proof. All components except for the RESET UNIT (watertight) must be installed in closed areas and protected from moisture. 0. Audible sial nerator The tone sequence (characteristic beeping) can be configured via the Service menu. The default setting is a long tone and long interval. The volume should be between 7 db and 8 db. If the internal sial nerator is insufficient, an external audible sial nerator must be connected to JE. The sial nerators for the second and third alarm must be dimensioned and installed according to the applicable standards. Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa 8 of
19 Technical Documentation BNWAS 000. Reset sensor The reset sensor can be supplied from a V power supply. The current must be less than 00 ma and must not exceed the total current (see Current). A reset may only be performed by persons on the id.. Location The RESET UNITS or WATCH ALARM MAIN UNIT must be clearly visible and easy to reach from the conning position, workstation for navigation, manoeuvring position, workstation for monitoring and id wing. The RESET UNIT and WATCH ALARM MAIN UNIT must be installed to allow easy access. Flashing mushroom buttons (WATCH ALARM MAIN UNIT, RESET UNIT) must be clearly visible to the OOW from any point on the id. The alarm of the WATCH ALARM MAIN UNIT (st alarm) must be clearly audible to the OOW from any point on the id. If external areas are to be included, the external sial nerator output must be used. Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa 9 of
20 Technical Documentation BNWAS 000. Compass safe distance Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa 0 of
21 Technical Documentation BNWAS 000 Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa of
22 Technical Documentation BNWAS 000. Commissioning The BNWAS must be configured as described in the operating instructions (accumulator charging current, REATER UNIT address, configuration menu) followed by a functional test. It must be ensured that no error messas are nerated and all functions work correctly as described. Any faults must be cleared. All standards and specifications relevant for installation must be observed! Following commissioning and acceptance, the configuration must be documented as a basic setting in the Service menu on the connected computer. For this purpose, a "C" for setting the UTC (GMT) time must be sent first, followed by an "s" for the Status/ Configuration menu, and after at least five minutes, an "e" for error messas and finally an "m" for the module list. The stored data must be handed to the customer in the form of a log sheet with date and siature tother with the delivery documents. The configuration data stored on the service computer is archived with the customer order. Tel.: +9 (0)0 / 0 0 * DECKMA GmbH * Fax: +9 (0)0 / 0. Installation instructions Version Pa of
1.5. System description of Bridge Navigation Watch Alarm System (BNWAS 3000)
1.5. System description of Bridge Navigation Watch Alarm System (BNWAS 3000) WATCH ALARM MAIN UNIT REPEATER UNIT SELECTOR UNIT RESET UNIT Revisions Version Date Author Checked Remark 1.0 10/01/13 JB TM
More information21-light Remote Annunciator. Owner s Manual
21-light Remote Annunciator Owner s Manual Annunciator Description... Inside Font Cover Detailed Specifications... 1 Environmental Specifications... 1 Power Supply Requirements... 1 Communication With
More informationFire Alarm System FMS3000 Installation Instructions
Fire Alarm System FMS3000 Installation Instructions Version history Version Date Author Checked Note 0.1 16/09/13 JB TK Produced based on the old operating instructions 0.2 27/09/16 TK STO Configuration
More informationRS485 MODBUS Module 8AI
Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationUser manual. KNXgal. version
User manual version 1.3 gal Management alarm control panels Galaxy from bus powered from bus Communication indication on and with Galaxy control panel DIN rail mount (1 modul) Adjustable address on with
More informationM2500 Engine Controller Installation Manual
M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...
More informationSCR100 User Manual. Version:1.1 Date:Dec 2009
SCR100 User Manual Version:1.1 Date:Dec 2009 Introduction: This document mainly introduces the installations and connections of SCR100 products, and the brief operations about attendance software. Important
More informationInstructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C
Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C 1. General The hand-held micro terminal is used for setting the motor parameters of the SILVER C. 2. Installation
More informationHEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING
-961212-0004 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. ( 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2) Connect
More informationRC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)
RC801/803/805-480B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,
More informationP2267 NETWORK INTERFACE
P2267 NETWORK INTERFACE USER MANUAL FOR OPERATING SYSTEMS: 22031-03 23636-01 October 2009 Associated Controls (Australia) Pty. Limited 2-4 Norfolk Road Greenacre, NSW, 2190. PH +61 2 9642 4922, FAX +61
More informationUSER MANUAL FOR OPERATING SYSTEM
P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177
More informationHRX Technical Manual. Version 1.2
HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire
More informationFX FIRE DETECTION SYSTEM
FX FIRE DETECTION SYSTEM Installation and commissioning manual Read this manual carefully before installation and commissioning! Installation and commissioning must be performed according to this manual.
More informationVAP304 PRO INSTALLATION & OPERATION MANUAL
VAP304 PRO INSTALLATION & OPERATION MANUAL Panic Fire Duress Program Bypass Report Chime Test Memory B A D C Program Chime Panic Duress Exit Fire Report Bypass Memory Test Reset Password Exit Reset Password
More informationSOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)
-961112-0003 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3
More informationUser Manual. Security Systems Security System L208
User Manual Security Systems Security System L208 a Contents This hand book is a technical instruction document for the installation, commissioning and operation of the L208 intrusion alarm security system.
More informationRTD-10 Installation Instructions
LED3 SW1 LED4 LED5 LED6 RTD-10 Installation Instructions +V S5 S6 POWER 15-24VDC English RTD-10 Installation Instructions 100.00 RTD-10 Control Interface realtime Control Systems 24VAC/3DC, 1A REMC P1
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS The SensorNet I/O Module provides attachment for up to 32 alarms and up to 16 switched devices. An RS-232 or RS-422 communications port is also provided for receiving serial alarms.
More informationISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE
Insulation monitoring device with integrated load and temperature monitoring and locating current injector for insulation fault location systems for medical IT systems _D00043_02_D_XXEN/09.2016 Insulation
More informationINSTALLATION INSTRUCTIONS. Anti Knocking System, AKR 3. Document no.: A SW version:
INSTALLATION INSTRUCTIONS Anti Knocking System, AKR 3 DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel: +45 9614 9614 Fax: +45 9614 9615 info@deifcom wwwdeifcom Document no: 4189340792A SW version: 1 General
More informationCarbon Monoxide Transmitter
Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or
More informationSOFTWARE VERSION 2.20 CONTROL PANEL RESET:
-961112-0002 SOFTWARE VERSI 2.20 CTROL PANEL RESET: Installer lock must be unlocked. ( 255: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (4) Wait 3
More informationRMS/RPX Reader. User Manual
RMS/RPX Reader User Manual Copyright Disclaimer Trademarks and patents Intended use FCC compliance Copyright 2005, GE Security Inc. All rights reserved. This document may not be copied or otherwise reproduced,
More informationLine Isolation Monitor (LIM) LIM2000plus
Line Isolation Monitor (LIM) LIM2000plus for Single and Three Phase Systems TDB207005usa/10.2008 BENDER Group Line Isolation Monitor LIM2000plus for Single and Three Phase Systems LIM2000plus Device features
More informationDigiplex System V2.14 / V2.2ACC. Control Panel Programming Guide
Digiplex System V2.14 / V2.2ACC Control Panel Programming Guide Table of Contents Getting Started...2 What Do I Do First?...2 How Do I Program the Control Panel?...2 Single Digit Entry Method...2 Multiple
More informationLifeAlarm Fire Alarm Control Panels
LifeAlarm Fire Alarm Control Panels UL, ULC Approved* Features Control panel operator convenience features: Wide viewing angle 2 x 20 (40 character) alphanumeric LCD and dedicated LEDs provide convenient
More informationR A D I O N I C S. READYKEY K2015A Alarm Event Manager. Installation Data Sheet. Description
R A D I O N I C S READYKEY K2015A Alarm Event Manager Installation Data Sheet READER CONTROLLER INPUTS INPUTS RLY 8 RLY 7 RLY 6 RLY 5 RLY 4 RLY 3 RLY 2 RLY 1 8 Supervised Inputs (Normally Open or Normally
More informationHEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING
48ESEP-01 SOFTWARE VERSION 3.10 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)
More informationUSER'S MANUAL. Real Time Color Quad Processor. High Resolution, Broadcast Quality. Playback Zoom Function. RS232 Remote Control
EverPlex 4CQ USER'S MANUAL EverPlex 4CQ + Freeze Seq NEXT P. DEFAULT Set Real Time Color Quad Processor High Resolution, Broadcast Quality Playback Zoom Function RS232 Remote Control Connect Up To 4 Cameras
More informationACCURATE ELECTRONICS INC
ACCURATE ELECTRONICS INC Page 1 of 7 Model 108078 2 Sept 09 WWW.ACCURATE.ORG PO BOX 1654 97075-1654 8687 SW Hall Blvd 97008 BEAVERTON OR USA 503.641.0118 FAX 503.646.3903 Practice Section 108078 Rev A
More informationProducts no longer available
Technical data sheet MONICO-.. Turnkey automation station MONICO-.. Forms an efficient fire protection system together with the motorisation sets BF(G)24MP Completely wired controller in matching control
More informationGas Detection System TOX ALARM DG2000-Garage
Gas Detection System TOX ALARM DG2000-Garage Gas Detection System 32 independent programmable channels 2 programmable alarm levels for each gas = up to 6 for each channel LCD alphanumeric display of gas
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint
More informationFire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63
Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.
More informationReplaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge
Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays
More informationType 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B
PRODUCT BULLETIN SB 8001B Type 8001 ALARM ANNUNCIATOR TYPE8001 FEATURES 16 or 32 alarm points per flush mount enclosure Displays are backlit with long life LEDs and engraved to suit Dimmer controls built
More informationParameterisable compact fault annunciator with permanent display
Parameterisable compact fault annunciator with permanent display FSM 10 Drop-flap fault annunciator 31.08.2010 Permanent display even on power failure Compact module for 10 alarms Supply and alarm signal
More informationWD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.
Data Sheet Ref: 90501085 WD-CS Water leak detection cable Technical Overview The WD-CS range of cable sensors are typically used to detect water leaks usually under floors, and are used in conjunction
More informationCAN bus-based I/O module, CIO relays Mounting Terminals and wiring Commissioning, using the utility software
INSTALLATION AND COMMISSIONING GUIDE CAN bus-based I/O module, CIO 208 8 relays Mounting Terminals and wiring Commissioning, using the utility software DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45
More informationoperating device LOD , 144x72mm designed for retrofit
BNWAS le guardian 225 sm electrics operating device LOD 2.24.., 44x72mm designed for retrofit connecting module LCM 2.24.. over 5 installations easy and comfortable use simple connections to all peripheral
More informationREPEATER FS5200R INSTRUCTION MANUAL
REPEATER FS5200R INSTRUCTION MANUAL Instruction Manual Page1 CONTENTS 1. Introduction... 3 2. Function... 3 3. Technical data... 3 4. Contents of delivery... 4 5. General information... 5 6. Duty Mode...
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationGeneral Purpose IO Technical Manual
General Purpose IO Technical Manual Revision 1.06 8 November 2013 Pakton Technologies PAE222 GPIO Manual.docx Page 1 of 21 Revision 1.06 Last updated 8/11/2013 Table of Contents INTRODUCTION...3 Scope
More informationRCS Residential Control Systems Inc.
RCS Residential Control Systems Inc. Model TZ16 Z-Wave Communicating Thermostat with Rev P HVAC Control Unit INSTALLATION AND OPERATION MANUAL DCN: 141-00882 Rev 02 5/18/06 This manual applies to the following
More informationInstructions for the fan motor control system with integrated wiring terminals SILVER C
Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.
More informationModBus DE-1 INSTALLATION AND USER MANUAL
ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN
More informationUser manual. KNXpar. version
User manual version 1.3 KNXpar Management alarm control panels Paradox from KNX bus Powered from KNX bus Communication indication on KNX and with Paradox control panel DIN rail mount (1 module) Adjustable
More informationOPERATION / INSTALLATION
OPERATION / INSTALLATION & PROGRAMMING MANUAL AFP-2800 LCD-80 Fire Alarm Panel Revision 1.01 November 16, 2004 NSW (Head Office) 7 Columbia Court Norwest Business Park Baulkham Hills NSW 2153 Ph: (02)
More informationINSTALLATION AND PROGRAMMING MANUAL
INSTALLATION AND PROGRAMMING MANUAL Contents Section 0. Section 1. Section 2. Section 3. Section 4. Section 5. Section 6. Section 7. Section 8. Section 9. Section 10. Section 11. Section 12. Section 13.
More informationHEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING
-961212-0004 SOFTWARE VERSI 3.10 CTROL PANEL RESET: Installer lock must be unlocked. (Address 058: enter any value other than 147) Power down reset (1) Remove battery and AC to power down the unit. (2)
More informationGLOBAL. InstallatIon & operation manual
InstallatIon & operation manual INDEX 1. INTRODUCTION... 5 2. FEATURES AND FUNCTIONS 2.1 Reporting Options... 2.2 Interfaces... 2.3 Programming... 2.4 Indicators and Controls...... 6 6 6 6 6 3. INSTALLATION...
More informationCONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.
CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse
More informationMulti-Gas-Controller MGC2
Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants
More informationTwo-Channel Gas Controller
Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously
More information20 Light Remote Annunciator
Light Remote Annunciator Owner s Manual Surface Mount Flush Mount 94-95- Standard Annunciator 94-, 94-95-, 95-4- 4- Annunciator w/remote Relay Panel 4-, 4-4-, 4-49-, 49-49-, 49- Time Multiplexed Annunciator
More informationInstallation and Operation Instructions
Smoke and Heat Ventilation Pneumatic - Electronic Control Systems Installation and Operation Instructions Version / SHEVS Control Centre RWZ d K + G Pneumatik GmbH In der Krause 8 9 Eschweiler Deutschland
More informationCentaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE
Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment
More informationRemote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number
Innovation In and Out of Parlour Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual Version - 1.0 Date - June 2016 Part Number - 39-0038 Index Manual Version... 3 About the Remote Vacuum
More informationPROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX
PROGRAMMING GUIDE SPECTRA CONTROL PANELS V1.2 1725, 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX TABLE OF CONTENTS HOW DO I PROGRAM THE SYSTEM?... 4 Single Digit Data Entry Method (Hexadecimal
More informationNGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3
NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic
More informationGeneral Routing Interface
General Routing Interface Features The General Routing Interface Card is an optional module to provide Fire and Fault Routing Outputs compliant with BSEN54-2: 1998 Clauses 7.9 and 8.9 and BS5839-1: 2002.
More informationAIS750 Series Alarm Annunciator User Manual (Ver. 2.3 / JUNE. 2014)
AIS750 Series Alarm Annunciator User Manual (Ver 23 / JUNE 2014) 3-350 John Street, Thornhill, tario L3T 5W6 Phone: 289 597 APEX (2739) Fax: 289 597 2200 Toll Free: 1 866 776 2943 Email: mail@annunciatorca
More informationDWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670
Bulletin AV-670 Series 670 Hood Monitor Specifications - Installation and Operating Instructions DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Phone: 219/879-8000 Fax: 219/872-9057
More informationME 3011C / Alarm Indication / Quick Reference Guide
Tables of Contents Page Application 1 Features 1 Important Safety Information! 2 Note to this Guide 2 Further Information 2 Device Variants 2 General Functions 3 Annunciator Sequences - ISA 18.1 3 Plan
More informationAnalog Room Pressure Monitor RPC Series
Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the
More informationisopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)
T M 1 isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012670 / 08.2013 isopv425
More informationEthernet General Purpose
Ethernet General Purpose Technical Manual Revision 1.03 8 November 2013 Pakton Technologies IO PAE224 Ethernet GPIO Manual.docx Page 1 of 22 Revision 1.03 Last updated 8/11/2013 Table of Contents INTRODUCTION...3
More informationDipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 505 Grünberg Tel.: 00 807-0 Fax: 00 807-259 Insulation monitoring device for unearthed AC/DC systems (IT systems for the supply of operating theatre
More informationSECTION 1 (Page 2) Introduction, standard accessories and mounting specifications.
HGM300 / RDM800 Refrigerant Monitoring System Instruction 3015-4149 Installation & Operation Mini Manual Rev. 5 November 2004 SECTION 1 (Page 2) Introduction, standard accessories and mounting specifications.
More informationOperating Manual MS220DA
ZIEHL industrie elektronik GmbH + Co KG Daimlerstraße 13, D 74523 Schwäbisch Hall + 49 791 504-0, info@ziehl.de, www.ziehl.de Temperature Relays and MINIKA Mains Monitoring Digital Panel Meters MINIPAN
More informationRevision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual
Revision 1.03 8 November 2013 JVA Technologies Ethernet General Purpose IO Technical Manual www.jva-fence.com.au Table of Contents INTRODUCTION...3 Scope and Purpose...3 Glossary...3 SPECIFICATIONS...4
More informationBooster Power Supply Manual
Supply Manual DEVELOPED BY COPYRIGHT NOTICE General Signal Building Systems Corporation 6411 Parkland Drive Sarasota, FL 34243 (941) 739-4300 Copyright 1999 General Signal Building Systems Corporation
More information1.7. Insulation fault evaluators EDS460/490 EDS461/491
Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-59 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control
More informationRC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual
RC802/804-240B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual Raisecom Technology Co., Ltd. (04/2005) 1. Cautions Please read the following notices carefully before installing and using the device,
More informationAFA 500 FUME HOOD ALARMS
AFA 500 FUME HOOD ALARMS Operating and Instruction Manual 19/7/03 Model AFA 500 Built-in or Remote sensor 2 Relay inputs 1 Relay output Com port Used for alarm indication and monitoring on Fume Cupboards
More informationErbium-Doped Fiber Amplifier (EDFA) - MW Series
Nanovation s MW series of EDFA products is designed for applications in advanced dense wave division multiplexing (DWDM) systems where high performance and reliability are critical. They are available
More informationHalton SAFE / 7.14 user guide and installation instructions
Halton SAFE / 7.14 user guide and installation instructions VERIFIED SOLUTIONS BY H A LTO N Enabling Wellbeing Table of contents 1 System description 3 2 User Accounts 4 3 Main menu 7 3.1 Main menu - Change
More informationSafety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device
Safety Instructions Used symbols Important Comments Before starting with installation of the MS 10B Alarm Unit, we recommend you to read the important information beneath. Qualification The installation
More informationUser manual for CPR32-NET network controller
Roger Access Control System User manual for CPR32-NET network controller Firmware version: 1.0.14 or newer Hardware version: 1.0 Document version: Rev. E 2016 ROGER sp. z o.o. sp.k. All rights reserved.
More informationColour Observation System
FAR < > NEAR Colour Observation system talk action menu _ + auto next FAR < > NEAR Colour Observation Monitor Colour Observation Monitor English Colour Observation System Table of contents Page Introduction...3
More informationDIVA8MG2. Compact PAVA System Master Unit. DIVA8 System
DIVA8MG2 Public Address - Voice Alarm Audio Distribution over IP Commercial Audio Intelligent Acoustic Solutions Intercommunication Loudspeakers Compact PAVA System Master Unit DIVA8 System DIVA8 system
More informationVM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM
VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM Integrated Voice Evacuation System VM-3000 series Emergency Voice Alarm System Incorporating Digital Audio PA, Paging and BGM High-quality, compact public
More informationJA-82KRC OASiS Control panel installation manual
JA-82KRC OASiS Control panel installation manual Installation manual: OASiS security system JA-82KRC 1 / 21 MKH51100 Contents: 1. Control panel architecture...3 1.1. Main features...3 1.1.1. Modes...4
More informationATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet
ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet EN 1 2 1 3 2 4 1 5 12V 6 2 0V D+ D- CON3 7 CON1 ON 3 1 2 3 4 1234 8 3 4 1 0 ON 1 2 3 4 METAL METAL Address 1 1 0 ON 1 2 3 4 Address 2 2011
More informationLEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL
LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL The LeakMonitor alarm panel is a microprocessor controlled fully adjustable alarm system suitable for multizone
More informationRS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL. USER MANUAL Read carefully before use
RS 0021 DIGITAL GAS DETECTION CONTROL UNIT FOR SENSORS WITH S-BUS PROTOCOL USER MANUAL Read carefully before use GENERAL INFORMATION This device is a gas control unit with RS485 serial communication, based
More informationDanfoss gas detection units
Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning
More informationInsulation fault evaluator EDS460-DG
Insulation fault evaluator for localising insulation faults in DC IT systems with a number of branch circuits where high system leakage capacitances are involved Preliminary data sheet TDB108021en/09.2008
More informationTri-Stack Smart System
Tri-Stack Smart System TM Notes & Warnings - The protection provided by this equipment may be impaired if it is not used in the manner specified herein. - Ensure all wiring meets applicable national and
More informationKT-100 Door Controller
WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully
More informationVPS3 Installation Manual
1-512-756-1678 VPS3 Installation Manual VPS3 Viewer (Local Unit) VPS3 Sender (Remote Unit) Content Introduction...2 Features...2 Packing Checklist...2 Patents...2 Limited Warranty...2 Overall Certificate...3
More informationSM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option
SM3000 Videographic Recorder User Guide (RTU) Communications Option ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow
More informationWIO200 Water In Oil measuring instrument
WIO200 Water In Oil measuring instrument You have made the right decision by choosing a measuring instrument from PAJ Systemteknik. Many customers buy our high standard products every year. There are at
More informationClassNK Technical Information No. TEC-0838 (iii) The dormant period, visual indication, first stage audible alarm, second stage remote audible alarm a
Subject Implementation of Bridge Navigational Watch Alarm System (BNWAS) (Excluding Japanese-flagged ships) To whom it may concern Technical Information No. TEC-0838 Date 8 December 2010 Paragraphs 2.2.3
More information1.7. Insulation fault evaluators EDS460/490 EDS461/491
Bender Incorporated 700 Fox Chase, Coatesville PA 1930 Tel.: (800) 356-466 Fax: (610) 383-7100 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control function
More informationCU 300. Installation and operating instructions GRUNDFOS INSTRUCTIONS
GRUNDFOS STRUCTIONS CU 300 Installation and operating instructions No contact Overvoltage Undervoltage Dry running Speed reduction Overtemperature Overload Sensor alarm Other languages www.grundfos.com/cu300-manual
More informationSystem Introduction. 1.1 Specifications S E C T I O N 1
System Introduction S E C T I O N 1 1.1 Specifications Control Panel Specifications Flexible Zone Configuration: 8 Fully Programmable Zones 37 Access Codes: 32 User, 1 System Master, 2 Partition Master
More informationFIRERAY 5000 range USER GUIDE
FIRERAY 5000 range USER GUIDE 0044-003-04 IMPORTANT PLEASE NOTE: The beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal.
More informationELT-KLED EliteSuite LED Keypad Installation Manual
ELT-KLED EliteSuite LED Keypad Installation Manual ELT-KLED EliteSuite Installation Manual PUBLICATION INFORMATION First Publication Draft Document Release Only Updated fire zone information Second Publication
More information