Electronic Control HPH-HPR-HPS User Manual

Size: px
Start display at page:

Download "Electronic Control HPH-HPR-HPS User Manual"

Transcription

1 True life inside Electronic Control HPH-HPR-HPS User Manual HP Firmware 3.1 EN air and water handling for a confortable life MC00005_04-EN - 01/2016

2 firmware 3.1 Rev.04 IT 2/ 51

3 Summary 1 Control Features Wiring the remote terminal User terminal MENU DESCRIPTION PGD Menu A. On/Off Unit B. Setpoint C. Clock/Scheduler D. Input/Output E. Data logger G. Service G.a. Change Language G.b. Information G.c. Summer/Winter G.d. Working hours G.e. BMS config G.f. Service setting G.f.a. Working hours set G.f.b. Probe adjustment G.f.c. Thermoregulation G.f.d. User DEV/Change PW G.g.Manual management H. Manufacturer H.a. Configuration H.b.I/O Configuration H.c. Factory settings H.d. Initialization H.e. Input/Output Test BMS USER VARIABLES ALARMS NOTE firmware 3.1 Rev.04 IT 3/ 51

4 1 Control Features Automatic selection EC fans management Management of the cooling circuit with inverter compressor Management of the cooling circuit with inverter compressor Reading pressure and temperature of the cooling circuit Management of cooling unit defrost Management of summer dehumidification Manual ON-OFF Cool/change over valve management Defrost recovery management Water coil anti-freeze management ON-OFF electric heater management Filter pressure switch management Management of ventilation with CO2 probe Management of ventilation with one or two pressure sensors Free-cooling modulating management Free-heating modulating management Management of mixing chamber Management of motorized dampers Alarms management Post ventilation Weekly programming Remote ON-OFF Mode change (hot/cold) from digital input Display on board machine Remote display Fixed point adjustment at flow Adjustment of temperature and ambient humidity BMS Modbus RS485 protocol firmware 3.1 Rev.04 IT 4/ 51

5 2 Wiring the remote terminal The remote terminal can be installed at max 50m using a 6 poles phone type cable. Connect the terminal into the A connector of TCONN6J000 TCONN6J000 board Wiring diagram for a distance up to 50 meters + _ alimentatore power supply 20 30Vdc 150mA address 21 max 50 m address 32 Remote terminal J14 and J15 on 2-3 TCONN6J000 Local terminal Only size MASTER address 1 SLAVE address 2 plan setting with remote controller When the display is ON press together the indicated buttons Display address Setting...: 21 I/O Board address: 01 Set Display address setting to 31 and press When the display is ON press together the indicated buttons Terminal config Press ENTER to continue Press Set as shown the following screen P:01 Adr Priv/Shared Trm1 32 Sh Trm2 21 Sh Trm3 None -- Ok?No twice Then select Ok?, set Yes and press. Now the matster board is configured firmware 3.1 Rev.04 IT 5/ 51

6 3 User terminal Display PGD The PGD1 is semi-graphic type with 8 rows per 22 columns with a 132x64 pixel resolution. There are 6 buttons used to set the system: PDG1 BUTTON ALARM See the active alarm list. BUTTON PRG Enter in main menu root. BUTTON ESC Back. + + BUTTON UP BUTTON DOWN BUTTON ENTER BUTTON ESC + BUTTON UP BUTTON ESC + BUTTON DOWN Scroll up or value increase. On main screen, direct access to set-point menu. Scroll down or value decrease. Enter in the selected submenu or confirm setting. On main screen turn ON-OFF the unit. Switch visualisation parameters circuit 1 or 2. Display contrast setting Press simultaneously + + and with the arrows set the contrast firmware 3.1 Rev.04 IT 6/ 51

7 Home page In the following image you can see the first page, showing mosto f the necessary information sto see the unit working mode. Date Clock State Unit On this windows you can see the working mode : STATE UNIT Unit off by Unit off by Unit off by Unit off by Unit off by State mode unit Alarm Supervision Scheduler Digital input keyboard Manual Cold Manual Hot Auto Cold Auto Hot Defrost State Heat recovery Defrost Heat pump defrost firmware 3.1 Rev.04 IT 7/ 51

8 Pressing down button you ll access the the following page. Compressor State Electric Pre Heater State Electric Post Heater State firmware 3.1 Rev.04 IT 8/ 51

9 Pressing up button you ll access the the following page. This page is active when regulation probe is the supply air sensor his page is active when regulation probe is the return air sensor. firmware 3.1 Rev.04 IT 9/ 51

10 To access these parameters, you must enter the password PW2 To access these parameters, you must enter the password PW1= 0010 HP User Manual 4 MENU DESCRIPTION PGD Menu A. On/Off Unit B. Setpoint C. Clock/Scheduler D. Input/Output E. Data logger G. Service a. Change Language b. Information c. Summer / Winter d. Working hours e. BMS config. f. Service settings g. Manual management a. Working hour set b. Probe adjustment c. Thermoregulation d. User DEV/Change PW1 H. Manufacturer a. Configuration Compressor/Inverter Driver EVD EVO o EVO OnBoard a. Configuration b. Regolation c. Custom b. I/O Configuration c. Factory settings d. Initialization e. Input/Output Test a. Configuration b. Regolation c. Custom firmware 3.1 Rev.04 IT 10/ 51

11 4.1. A. On/Off Unit On the main menu (A.) you can set the unit state. Or pressing the buttons Esc+UP from every first level menu. + TASTO ESC + TASTO SU Premere contemporaneamente i tasti Esc+UP per accendere/spegnere l unità B. Setpoint The following figures shows the set-point screens. Page active with regulation on return air sensor, automatic mode Page active with regulation on return air sensor, manual mode Page active with dehumidification active Page active with air quality sensor active active firmware 3.1 Rev.04 IT 11/ 51

12 4.3. C. Clock/Scheduler Working mode: The controller has an internal clock with a battery that preserve the clock operation. Time and date setting and scheduler setting can be done on C.Clock/Scheduler menu. The related screen are: Time and date setting; Summer time enabling and setting; Scheduler enabling; Profile 1; Profile 2; Profile 3; Profile enabling. See the following screens: Time and date setting Summer time enabling and setting Scheduler must be enable on the following screen: Scheduler enabling You can set on this screen 3 different set-points called profiles Each profile includes the automatic and manual unit set-points and enabling of night fan speed reducing. Once profiles have been defined you can set every half hour the required profile. firmware 3.1 Rev.04 IT 12/ 51

13 On the screen you can: select the day of the week move on the timer ange and set the profile copy the day schedule on an other day None rectangle: Status = OFF Low rectangle: Profile 1 Medium rectangle: Profile 2 High rectagle: Profile D. Input/Output On this menu you can see the analog and digital input and output status. In case of not used I/O you ll see ---. B00 = Number of analog input and description ID00 = Number of digital input and description firmware 3.1 Rev.04 IT 13/ 51

14 NO00 = Number of digital output and description Compressor data screen Heat pump data screen Heat pump data screen firmware 3.1 Rev.04 IT 14/ 51

15 Compressor data screen EEV data screen Compressor data screen Compressor data screen Compressor data screen Compressor data screen firmware 3.1 Rev.04 IT 15/ 51

16 Compressor data screen Compressor data screen firmware 3.1 Rev.04 IT 16/ 51

17 firmware 3.1 Rev.04 IT 17/ 51

18 4.5. E. Data logger On this menu you can see the alarm history; to reset them you need to enter on service menu (password is needed). Pressing the alarm button you can mute the buzzer, and see the active alarms and reset them (of course the alarm log will not be reset) and then directly enter in the alarm history menu. alarm date alarm clock alarm sequence number firmware 3.1 Rev.04 IT 18/ 51

19 4.6. G. Service This menu is divided inn sub-menu, the first four (a,b,c,d) are not password protected and allos you to set the following: 4.7. G.a. Change Language Language set-up: To exit press button 4.8. G.b. Information you can find information about software code and version, and installed electronic board. firmware 3.1 Rev.04 IT 19/ 51

20 4.9. G.c. Summer/Winter Automatic or manual season changeover G.d. Working hours You can see the working hours of the main components installed on the unit. firmware 3.1 Rev.04 IT 20/ 51

21 Note: to access to the following sub-menu you need to enter the service password (PW1 ) G.e. BMS config. BMS setting: all the parameters necessary to set a BMS communication G.f. Service setting G.f.a. Working hours set Working hour setting: it allows to set the maximum working hour of unit main components that need a periodic maintenance. On the same screen you can reset the worked hours of each component. firmware 3.1 Rev.04 IT 21/ 51

22 G.f.b. Probe adjustment Sensors calibration: you can set an offset to add or remove on each sensor reading. Once confirmed the sensor value is automatically updated (reported on side). firmware 3.1 Rev.04 IT 22/ 51

23 firmware 3.1 Rev.04 IT 23/ 51

24 G.f.c. Thermoregulation Setting of thermoregulation. Screen active with free-cooling active firmware 3.1 Rev.04 IT 24/ 51

25 Screen active with free-cooling active Screen active with free-heating active Screen active with free-heating active firmware 3.1 Rev.04 IT 25/ 51

26 R1 R2 R3 HP User Manual QPM2100 remove jumper R3 remove jumper QPM2100 Q R3 jumper open= 0-5V R3 jumper close= 0-10V firmware 3.1 Rev.04 IT 26/ 51

27 Set (%)costant flow pressur sensor: Taglia k Taglia k firmware 3.1 Rev.04 IT 27/ 51

28 G.f.d. User DEV/Change PW1 User DEV/Change PW1: you can reset the alarm history and change the password PW G.g.Manual management firmware 3.1 Rev.04 IT 28/ 51

29 4.14. H. Manufacturer To access to this menu you need the manufacturer password (PW2 ): HP User Manual H.a. Configuration Configuration: you can select the main features of the unit and the operation of each component. On the following screens you can see the features of the installed components and the hardware seting. You can also see the EEV driver setting (a.configuration, b.regolation, c.custom ) and of the compressor / driver (a.configuration, b.regolation, c.custom). These parameters are related to the serial port of the compressor driver. firmware 3.1 Rev.04 IT 29/ 51

30 These parameters are related to the serial port of the compressor driver. firmware 3.1 Rev.04 IT 30/ 51

31 4.16. H.b.I/O Configuration I/O Configuration On this menu you can activate and set each I/O. firmware 3.1 Rev.04 IT 31/ 51

32 firmware 3.1 Rev.04 IT 32/ 51

33 4.17. H.c. Factory settings Factory setting: the following screens allows the set all the manufacturer reserved parameter. firmware 3.1 Rev.04 IT 33/ 51

34 firmware 3.1 Rev.04 IT 34/ 51

35 firmware 3.1 Rev.04 IT 35/ 51

36 firmware 3.1 Rev.04 IT 36/ 51

37 4.18. H.d. Initialization Default installation: complete reset of the default value. On this screen you can change the manufacture value H.e. Input/Output Test firmware 3.1 Rev.04 IT 37/ 51

38 GND RX/TX + RX/TX - HP User Manual 5 BMS USER VARIABLES The unit can be connected the several supervision system, in particular the following BMS protocols can be used: Carel and Modbus. The connection is made by a BMS serial port. The connetion protocol is managed by the following optional board: Modbus RS485: cod. PCOS (see Fig. 8.a) On the following figure you can see the connection diagram between BMS and upc. MASTER Fig. 8.a Note: Suggested cable for data line with ohm impedance type BELDEN 3105A EIA Industrial RS-485 PLTC/CM The following table shows the variables shared with supervisor. Nota: On the first column shows the Carel address, the second one the ModBus address (packet), in case of register communication mode, the address of the ModBus column must be increased of 1, both for digital variable (coil) and for analog variable (register). Nota: (*) nome indica il nome della variabile utilizzato internamente per il programma di commissionino firmware 3.1 Rev.04 IT 38/ 51

39 CAREL MODBUS COIL (1)-Digital/MODBUS TAG NAME TAG DESCRIPTION 1 2 DIGITAL INPUT 1 din1_msk 2 3 DIGITAL INPUT 2 din2_msk 3 4 DIGITAL INPUT 3 din3_msk 4 5 DIGITAL INPUT 4 din4_msk 5 6 DIGITAL INPUT 5 din5_msk 6 7 DIGITAL INPUT 6 din6_msk 7 8 DIGITAL INPUT 7 din7_msk 8 9 DIGITAL INPUT 8 Din8_msk 9 10 DIGITAL INPUT 9 Din9_msk DIGITAL INPUT 10 Din10_msk Status of digital input (0=Closed; 1=Open) Status of digital input (0=Closed; 1=Open) Status of digital input (0=Closed; 1=Open) Status of digital input (0=Closed; 1=Open) Status of digital input (0=Closed; 1=Open) Status of digital input (0=Closed; 1=Open) Status of digital input (0=Closed; 1=Open) Status of digital input (0=Closed; 1=Open) Status of digital input (0=Closed; 1=Open) Status of digital input (0=Closed; 1=Open) DIGITAL OUTPUT 1 Dout1_Value (0-Open;1-Close) DIGITAL OUTPUT 2 Dout2_Value (0-Open;1-Close) DIGITAL OUTPUT 3 Dout3_Value (0-Open;1-Close) DIGITAL OUTPUT 4 Dout4_Value (0-Open;1-Close) DIGITAL OUTPUT 5 Dout5_Value (0-Open;1-Close) DIGITAL OUTPUT 6 Dout6_Value (0-Open;1-Close) DIGITAL OUTPUT 7 Dout7_Value (0-Open;1-Close) DIGITAL OUTPUT 8 Dout8_Value (0-Open;1-Close) DIGITAL OUTPUT 9 Dout9_Value (0-Open;1-Close) DIGITAL OUTPUT 10 Dout10_Value (0-Open;1-Close) DIGITAL OUTPUT 11 Dout11_Value (0-Open;1-Close) DIGITAL OUTPUT 12 Dout12_Value (0-Open;1-Close) Summer-winter working mode Summer -Winter Status (0: Summer; 1: Winter) BMS On/Off Off-On Status (0: Off; 1: On) A001 Clock board error firmware 3.1 Rev.04 IT 39/ 51

40 A002 Extend memory error A003 Compressor start-up failed A004 Envelope zone alarm: A005 High compressor discharging temperature A006 Low pressure difference A007 Inverter type not compatible A008 Power+ Device Offline A009 Power+ see Inverter erros list A010 S1 sensor failure Low pressure A011 S2 sensor failure Compressor Suction Temp A012 S3 sensor failure High pressure A013 S4 sensor failure Compressor discharge Temp A014 (LowSH) Low overhetaing A015 (LowSH) Low overheting A016 (LOP) Low evaporation temperature A017 (LOP) Low evaporation temperature A018 (MOP) High evaporation temperature A019 (MOP) High evaporation temperature A020 High condensing temperature A021 Low condensing temperature A022 Low suction temperature A023 Autotune Valve A A024 Autotune Valve B NOT USED NOT USED NOT USED NOT USED A027 High Pressure Alarm Compressor A028 Low Pressure Allarm Compressor A029 Disabled Compressor Start DP A030 Air Flow Switch (ID) A031 Fan Alarm (ID) A032 Filter Pressure Switch Supply/Return (ID) A033 High Pressure Alarm Compressor 1 (ID) A034 Mix room alarm A035 B1 sensor failure Exhaust temp A036 B2 sensor failure Fresh air temp A037 B12 sensor failure Air quality sensor A038 NOT USED NOT USED A039 NOT USED NOT USED A040 Door Micro switch Alarm A041 High Pressure Prevention Function A042 B8 sensor failure Saturation Temp A043 B9 sensor failure Return Temp A044 B10 sensor failure Return humidity A045 Circuit 2 Offline A046 Circuit 1 Offline A047 Circuit 1 Alarm A048 Circuit 2 Alarm A049 B3 sensor failure Supply temp. firmware 3.1 Rev.04 IT 40/ 51

41 A050 Electric Heating Thermal protection Comp_On_1 Compressor power on Request to switch on/off compressor Comp_Request_Env from envelope En_Inverter EnablePower + Inverter CAREL MODBUS INPUT (2)- Analog/MODBUS TAG NAME TAG DESCRIPTION 1 2 ANALOG INPUT VALUE 1 Ain1_Std_UM Exhaust temp. 2 3 ANALOG INPUT VALUE 2 Ain2_Std_UM Fresh air temp. 3 4 ANALOG INPUT VALUE 3 Ain3_Std_UM Supply air temp. 4 5 ANALOG INPUT VALUE 4 Ain4_Std_UM Compressor 1 suction temp. 5 6 ANALOG INPUT VALUE 5 Ain5_Std_UM Compressor 1 discharge temp. 6 7 ANALOG INPUT VALUE 6 Ain6_Std_UM C1 high pressure transducer 7 8 ANALOG INPUT VALUE 7 Ain7_Std_UM C1 low pressure transducer 8 9 ANALOG INPUT VALUE 8 Ain8_Std_UM Saturation temp ANALOG INPUT VALUE 9 Ain9_Std_UM Return air temp ANALOG INPUT VALUE 10 Ain10_Std_UM Return air humidity ANALOG INPUT VALUE 11 Ain11_Std_UM ANALOG INPUT VALUE 12 Ain12_Std_UM Air quality sensor ANALOG OUTPUT Y1 Supply fan ANALOG OUTPUT Y2 Return fan ANALOG OUTPUT Y3 Water valve ANALOG OUTPUT Y4 By-pass modulating damper RoomSet_Heat Room PI regulheatig setpoint RoomSet_Cool Room PI regul cooling setpoint RoomSetP_Operative Calculated Set point DelivAirSetP_Temp Delivery air setpoint (calculated) firmware 3.1 Rev.04 IT 41/ 51

42 ANALOG INPUT VALUE 4 SLAVE Compressor 2 suction temp ANALOG INPUT VALUE 5 SLAVE Compressor 2 discharge temp ANALOG INPUT VALUE 6 SLAVE C2 high pressure transducer ANALOG INPUT VALUE 7 SLAVE C2 low pressure transducer Return air Set-point (automatic mode) RoomSetP Room setpoint Return air Set-point (summer) RoomSetP_Summer Return air set-point (winter) RoomSetP_Winter Neutral zone RoomDeadBand Rotor_Speed_Hz Rotor_Speed_rps_1 Compressor rotor speed rps [1/10rps] Maximum_output_freq uency_rps Maximum power+ output frequency set (Rps) Minimum_output_freq uency_rps Minimum drive output frequency (rps) Motor_Current Motor current [1/10 A] Inverter_Req_0_1000 Speed request to inverter (filtered by envelop) [1/10%] A100_DISCHARGE_SH_ SET_1 SetPoint of Discharge SH (EE Valve subregulation) [1/10 C] A101_DISCHARGE_TEM P_SET_1 SetPoint of Discharge Temp (EE Valve subregulation) [1/10 C] MOP_Inhibition_Thr_1 to EVD Pin of MOP inhibition threshold A107_MOP_THRESHOL D_FAST_CHANGE_ A106_S4_NTC_THERM AL_TIME_K_ Evap_Reg_Setpt_T_1 Evaporating temp. limit Setpoint (Fan regul. in Pdc) [1/10 C] Evap_Reg_Setpt_P_1 Evaporating press.limit Setpoint (Fan regul. in Pdc) (1/10bar] Cond_Reg_Setpt_P_1 Condensing press. limit Setpoint (Fan regul. in chiller) [1/10bar] Cond_Reg_Setpt_T_1 Condensing temp. limit Setpoint (Fan regul. in chiller) [1/10 C] Suction_Temp_A1 Suction temperature - EE valve [1/10 C] firmware 3.1 Rev.04 IT 42/ 51

43 Evaporation_Temp_A1 Evaporation temperature - EE valve [1/10 C] Evaporation_Press_A1 Evaporation pressure valve A Superheat_A1 Superheat - EE valve [1/10 C] Condensing_Press1 Condensing pressure Condensing temperature - EE Valve Condensing_Temp1 [1/10 C] A104_DISCHARGE_SH Tdischarge_Gas_EVO A10_SH_SH Superheat valve A Discharge gas temperature with EVD [1/10 C] A5_SH_SUCT_TEMP Suction temperature valve A A17_EEV_POSITION_PE RCENT_SHOW A7_SH_EVAP_PRES Evaporation pressure valve A A6_SH_EVAP_TEMP Evaporation temperature valve A CAREL MODBUS INTEGER (3)- INTEGER/MODBUS TAG NAME TAG DESCRIPTION Unit_Status {;Unit'ON;OFFbyALR;OFFbyNET;OFFbyBMS;OFFbyFSC;OF FbyDIN;OFFbyKEY;;OFF_CST1;OFF_CST2;OFF_CST3;OFF_ CST4;} SetSpeedExhaustFan Set Speed of exhaust fan (FAN1) SetSpeedSupplyFan Set speed of supply fan (FAN2) AOut3 ( Valvola Acqua ) Analogic Output Y3 value firmware 3.1 Rev.04 IT 43/ 51

44 Envelope_Zone_ Envelopeworking zone: 0=Null;1=OK;2=Max.comp.R.;3=Max.disch.P.;4=HCurr.;5 =Max.suct.P.;6=Min.comp.R.;7=LowDP;8=Min.disch.P.;9= Min.suct.P Inv_PowerPlus_Device_Number Progressive device nr. in the system Current_error_code_1 Inverter error code: 0: No fault;1: Overcurrent;2: Motor overload;3: Overvoltage;4: Undervoltage;5: Drive overt.;6: Drive undert;7: Overcurrent HW;8: Motor overtemp.;9: Reserved;10: Cpu error;11: Param. default;12: DC bus ripple;13: Data comms fault;14: Drive thermistor;15: Autotune fault;16: Drive disabled;17: Motor phase;18: Fan fault;19: Speed fault Alarm_Code_EBM Alarm_Code_EBM firmware 3.1 Rev.04 IT 44/ 51

45 Rotor_Speed_0_1000 Compressorrotorspeed Rotor_Speed_rpm Compressorrotorspeed [rpm] Drive_Status Show the inverter status: 0 = Stopped 1= run 2 = alarm Motor_Voltage Motor Voltage [V- Integer] Drive_Temp Inverter Temperature [ C] DC_Bus_Voltage DC Bus Voltage [V] Current_error_code_1 Inverter error code: 0: No fault;1: Overcurrent;2: Motor overload;3: Overvoltage;4: Undervoltage;5: Drive overt.;6: Drive undert;7: Overcurrent HW;8: Motor overtemp.;9: Reserved;10: Cpu error;11: Param. default;12: DC bus ripple;13: Data comms fault;14: Drive thermistor;15: Autotune fault;16: Drive disabled;17: Motor phase;18: Fan fault;19: Speed fault Refrigerant_1 Gas type - Valve A Actual circuit cooling capacity for EVD valve from Circuit_Cooling_Capacity_Env_A envelope I89_REGULATION_SUB_TYPE_1 regulationsubtipe Env_Countdown_1 Countdown of out of envelop alarm [s] Envelope_Zone_ Disch_Temp_Zone_ Motor_Type Envelopeworking zone: 0=Null; 1=OK; 2=Max.comp.R.; 3=Max.disch.P.; 4=HCurr.; 5=Max.suct.P.; 6=Min.comp.R.; 7=LowDP; 8=Min.disch.P.; 9=Min.suct.P. Discharge temperature zone: 0 = null; 1= OK; 2 = Controlled; 3 = Limited 0=Custom; 1=Siam ANB33F-400V; 2=Siam ANB42F- 400V;3=Siam ANB52F-400V;4=Samsung UG5T520F-400V LP_cents_EVO_high_precision Low pressure: cents of Bar HP_cents_EVO_high_precision High pressure cents of Bar I4_EEV_POSITION_STEPS Position valve A I8_REG_STATUS EVD Evolution OnBoard regulation status valve A firmware 3.1 Rev.04 IT 45/ 51

46 firmware 3.1 Rev.04 IT 46/ 51

47 6 ALARMS When Alarm button is blinking an alarm is active. Pressing the button you directly acces to the active alarm list. Note: Two alarm need to be manually reset (inverter and doors micro switch), to reset them keep pressed the Alarm button, once done the system automatically switches to the home page. N ALARM end DESCRIPTION CHECK TO BE DONE A001 Clock board error Replace the button battery (CR2430 3V type) A002 Extend memory error Replace main PCB A003 Compressor start-up failed (Check motor connection)(tent.: / max.: ) Check compressor motor wiring (follow the electric wiring diagram supplied with the unit) A004 Envelope alarm Zone:1,2,3,4,5,6,7,8,9 see Envelope Alarm Contact service dept list A005 High compressor discharging temperature Contact service dept A006 Low pressure difference (poor lubrication.) Contact service dept A007 Inverter type not compatible (only type Power+) Contact service dept A008 Power+ n Device Offline Check compressor driver power supply and wiring A009 Power+ n see Inverter error list Contact service dept A010 S1 sensor failure (Low pressure) A011 S2 sensor failure (Compressor Suction Temp.) A012 S3 sensor failure (High pressure) A013 S4 sensor failure (Compressor discharge Temp.) A014 (LowSH) Low overheating valve A- A015 (LowSH) Low overheating valve B- A016 (LOP) Low evaporation temperature valve A- A017 (LOP) Low evaporation temperature valve B- A018 (MOP) High evaporation temperature valve A- A019(MOP) High evaporation temperature valve B- A020 High condensing temperature (HiTCond) A021 Low suction temperature valve A- A022 Low suction temperature valve B- A023 Autotune Valve A- A024 Autotune Valve B- A025 NOT USED A026 NOT USED A027 High Pressure Alarm Compressor 1 Check wiring and sensor type (SPKT0043R0 0-17,3bar) Check wiring and sensor type (NTC030WF00) Check wiring and sensor type (SPKT00B6R0 0-44,8bar) Check wiring and sensor type (NTC030HTF00) Contact service dept NOT USED Contact service dept NOT USED Contact service dept NOT USED Contact service dept Contact service dept NOT USED Contact service dept NOT USED NOT USED NOT USED 1) Summer mode: exhaust airflow too low a. exhaust fan speed too low b. dirty filters or clogged ductwork c. air conditions over limit 2) Winter mode: supply airflow rate too low a. supply fan speed too low b. dirty filters or clogged ductwork 3) Freon filling too high A028 Low Pressure Alarm Compressor 1 1) Summer mode: supply airflow too low a. supply fan speed too low b. dirty filters or clogged ductwork firmware 3.1 Rev.04 IT 47/ 51

48 c. outside air conditions over limit 2) Winter mode: exhaust airflow too low a. exhaust fan speed too low b. dirty filters or clogged ductwork c. air conditions over limit 3) Freon filling insufficient A029 Disabled Compressor Start DP A030 Air Flow Switch (DI) A031 Fan Alarm (DI) A032 Filter Pressure Switch Supply/Return (DI) A033 High Pressure Alarm Compressor 1 (DI) A034 Mix box alarm A035 B1 sensor failure (Exhaust temp.) A036 B2 sensor failure (Fresh air temp.) A037 B12 sensor failure (Air quality sensor) A038 NOT USED A039 NOT USED A040 Door Micro switch Alarm A041 High Pressure Prevention Function Contact service dept Check digital input DI4 Check fan fuses or replace fans Clean or replace air filter Check digital input DI6 Additional PCB SMD4500 failure (managing mixing box and modulating electric pre-heater) Check sensor wiring or replace it (NTC10k 25 C) Check sensor wiring or replace it (NTC10k 25 C) Check sensor wiring or replace it (2000ppm 0-5V) NOT USED NOT USED Check digital input DI5 Reduced operation mode warning. 1) Summer mode: bassa exhaust airflow too low a. exhaust airflow too low b. dirty filters or clogged ductwork c. air conditions over limit 2) Winter mode: supply airflow too low a. supply fan speed too low b. dirty filters or clogged ductwork c. air conditions over limit 4) Freon filling too high A042 B8 sensor failure (Saturation Temp.) Check sensor wiring or replace it (NTC10k 25 C) A043 B9 sensor failure (Return Temp.) Check sensor wiring or replace it (NTC10k 25 C) A044 B10 sensor failure (Return humidity) Check sensor wiring or replace it (0-100% 4-20mA) A045 Circuit 2 Offline Check compressor driver & main PCB Modbus connection A046 Circuit 1 Offline Check compressor driver & main PCB Modbus connection A047 Circuit 1 Alarm Alarm conditions on circuit 1 while visualizing circuit 2.. Select circuit 1 by keys + A048 Circuit 2 Alarm Alarm conditions on circuit 2 while visualizing circuit 1. Select circuit 2 by keys + A049 B3 sensor failure (Supply temp.) Check sensor wiring or replace it (NTC10k 25 C) A050 Electric Heating Thermal protection Insufficient airflow rate firmware 3.1 Rev.04 IT 48/ 51

49 ENVELOPE ERROR 1: Inside envelope 2: High compression ratio 3: High condensing pressure 4: High current 5: High evaporation pressure 6: Low compression ratio 7: Low pressure difference 8: Low condensing pressure 9: Low evaporating pressure ENVELOPE ERROR 1: Over current 2: Motor over current 3: High voltage 4: Low voltage 5: High temperature 6: Low temperature 7: HW overcurrent 8: Motor High temperature 9: Drive fault 10: Cpu error 11: Default parameters 12: DC bus ondulation 13: timeout com.ser. 14: Thermistor error 15: Autotuning error 16: Drive disabled 17: Motor missing phase 18: Fan fault 19: Motor stalemate 20: PFC module fault 21: Alarm code 21 22: PFC low voltage 23: STO reading error 24: STO reading error 25: Alarm code 25 26: Alarm code 26 27: Alarm code 27 28: Alarm code 28 29: Alarm code 29 30: Alarm code : Unexpected inverter stop firmware 3.1 Rev.04 IT 49/ 51

50 HPR-H-S k x Fan N Fan RH25C RH31C GR35C GR40C GR45C Air flow m³/h (V) MAX HPR-H HPR-H Air flow m³/h (V) MAX HPS HPS Air flow m³/h (V) Min HPR-H HPR-H Air flow m³/h (V) Min HPS HPS Set DP (Pa) MAX HPR-H Set DP (Pa) MAX HPS DP (Pa)= (V/k)² Set DP (Pa) Min HPR-H Set DP (Pa) Min HPS DP (Pa)= (V/k)² FSS Pressure sensor range (Pa) Signal % 0-10V MAX HPR-H Signal % 0-10V MAX HPS %= (Set/FSS)*100 Signal % 0-10V Min HPR-H All Signal % 0-10V Min HPS Set= 10% (1.0V) Signal % 0 10V = Set DP (Pa ) FSS 100 firmware 3.1 Rev.04 IT 50/ 51

51 NOTE firmware 3.1 Rev.04 IT 51/ 51

Service control manual Smart HP. Application FLBB0mHPGU

Service control manual Smart HP. Application FLBB0mHPGU Service control manual Smart HP Application FLBB0mHPGU 1 Summary 1. INTRODUCTION...3 1.1 Purpose of the manual...3 2. SYSTEM ARCHITECTURE...4 2.1 Main control components...4 3. USER INTERFACE...5 3.1 Terminal...5

More information

Operation manual. Rooftop Packaged Unit

Operation manual. Rooftop Packaged Unit Operation manual Rooftop Packaged Unit odels: UATYQ20ABAY1 UATYQ25ABAY1 UATYQ30ABAY1 UATYQ45ABAY1 UATYQ50ABAY1 UATYQ55ABAY1 UATYQ65ABAY1 UATYQ75ABAY1 UATYQ90ABAY1 UATYQ110ABAY1 UATYQ115ABAY1 UATYQ20AFC2Y1

More information

DC 60 & DM 60 displays

DC 60 & DM 60 displays USER MANUAL DC 60 & DM 60 displays BALTIC FLEXAIR ENERGY AIRCOOLAIR COMPACTAIR FLATAIR (& Inverter) AQUALEAN DC60-DM60-IOM-1310-E www.lennoxemea.com Summaries 1 Display DC60 1.1 Introduction... 2 1.2

More information

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Modular Standard HP Chiller 1/4 screw compressor with Carel driver Program for pco¹ pco 2 and pcoc Modular Standard HP Chiller 1/4 screw compressor with Carel driver Manual version 1.0 25 September 2003 Program code: FLSTDmMSDE Do we want you to save you time and money?

More information

REMOTE CONTROL FOR CHILLER MYCHILLER

REMOTE CONTROL FOR CHILLER MYCHILLER REMOTE CONTROL FOR CHILLER MYCHILLER GENERAL FEATURES... 3 MAIN FUNCTIONS AND EQUIPMENT:... 3 LCD DISPLAY... 4 KEYBOARD... 5 BOARD CONFIGURATION... 7 LIST OF MAIN PARAMETERS... 7 CONFIGURATION OF MAIN

More information

MLCFC HMI NAVIGATION MANUAL

MLCFC HMI NAVIGATION MANUAL MLCFC HMI NAVIGATION MANUAL MOTIVAIR CORPORATION 85 WOODRIDGE DRIVE AMHERST, NY 14228 Phone# 716-691-9222 Fax# 716-691-9229 www.motivaircorp.com MAIN MENU 20:55 10/09/12 M0 Water inlet 12,0 C Water outlet

More information

Standard Chiller Modular HP 1/4 Generic/Bitzer screw compressor and CAREL valve

Standard Chiller Modular HP 1/4 Generic/Bitzer screw compressor and CAREL valve Application program for pco¹ pco² pco 3 Standard Chiller Modular HP 1/4 Generic/Bitzer screw compressor and CAREL valve 1.1 09 / 11 / 2006 version of manual Program code: FLSTDmMSBE We wish to save you

More information

User Manual Ichill 200 L/D (Firmware version 1.7)

User Manual Ichill 200 L/D (Firmware version 1.7) User Manual Ichill 2 L/D (Firmware version 1.7) Pag. 1 of 142 INDEX 1. GENERAL FEATURES...8 1.1 Main Function... 8 2. ICHILL 2L/D TABLE OF THE FEATURES...1 3. USER INTERFACE...11 4. REMOTE KEYBOARD...15

More information

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products Document 475595 Microprocessor Controller for Tempered Air Products Reference Guide for the Microprocessor Controller Please read and save these instructions. Read carefully before attempting to operate

More information

N M AirControl AHU. Control manual

N M AirControl AHU. Control manual N 10.63 M 03-2016 AirControl AHU Control manual EN CONTENTS PAGE 1 - MONITORING AND CONTROL 2 1.1 The program 2 1.2 The HMI terminal 2 1.3 The controller 4 1.4 Description of the air handling units 4

More information

Products no longer available

Products no longer available Technical data sheet MONICO-.. Turnkey automation station MONICO-.. Forms an efficient fire protection system together with the motorisation sets BF(G)24MP Completely wired controller in matching control

More information

User manual for reversible heat pump

User manual for reversible heat pump User manual for reversible heat pump Heat pump system integrated in Geniox, DV or TIME air handling unit Manual version 1.01.14 Part number of this manual 90925374 Contents DECLARATION OF CONFORMITY EXAMPLE...2

More information

C5-12 OPERATION MANUAL

C5-12 OPERATION MANUAL C5-12 OPERATION MANUAL C5-12 Controls 1 Overview... 3 1.1 Introduction... 3 1.2 Model numbers explained... 3 1.3 Product series overview... 4 1.4 Hardware Controller... 4 1.5 Controller Inputs and Outputs...

More information

CONTROLS MANUAL. CARRIERrtc basic & medium electronic control 48/50 EN/EH 50 HB/HF/NZ/NF. Original document

CONTROLS MANUAL. CARRIERrtc basic & medium electronic control 48/50 EN/EH 50 HB/HF/NZ/NF. Original document CONTROLS MANUAL CARRIERrtc basic & medium electronic control 48/50 EN/EH 50 HB/HF/NZ/NF Original document Contents 1. General description....5 2. Set-up... 6 2.1. micropc control board... 6 2.2. TCO user

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE MANUAL Prg Sel line alarm on on/off alarm enter Clear EMIpro MICROPROCESSOR CONTENTS 1 GENERAL CHARACTERISTICS Page 2 1.1 General description Page 2 2 EMIPRO USER INTERFACE Page

More information

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE Release January 2001 CONTENTS 1.0 GENERAL CHARACTERISTICS... 4 1.1 MAIN CHARACTERIS TICS... 4 2.0 USER INTERFACE (CODE C5121230)... 5 2.1 DISPLAY... 5 2.2 MEANING OF THE LEDS...

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

Reference Guide for Microprocessor Controller

Reference Guide for Microprocessor Controller Document 483232 Microprocessor Controller for Energy Recovery Reference Guide for Microprocessor Controller Please read and save these instructions for future reference. Read carefully before attempting

More information

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV CyCLO User Guide Version 2.00 19 th December 2017 REV 2.00 1 Contents 1. Hardware... 3 1.1. Introduction... 3 1.2. Electrical Specification... 3 1.3. Board Overview... 4 1.4. Electrical Installation...

More information

Multi-zone Standard air-conditioning units

Multi-zone Standard air-conditioning units Application program for pco¹ and pco 2 Multi-zone Manual version 1.1 15 April 2004 Program code: FLSTDEMARE To save time and money! The thorough reading of this manual will ensure proper installation

More information

1.0 Digital Controller

1.0 Digital Controller 1.0 Digital Controller...1 1.1 Display Function Keys...1 1.2 Thermostat Display...2 1.3 Controller hardware input output points... 4 2.0 Sequence of Operation...5 2.1 States of Operation...5 2.2 Modes

More information

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB Summary 1 CONNECTIONS... 8 1.1 TEMPERATURE PROBES...8 1.2 PRESSURE PROBES...9 1.3 LOW VOLTAGE DIGITAL INPUTS...10 1.4 LIVE DIGITAL INPUTS...11 1.5 RELAY OUTPUTS...12 2 VOLTAGE/FREQUENCY INPUT...13 3 POWER

More information

Product Features Technical Training 2007

Product Features Technical Training 2007 Product Features Product Features Less foot print occupied Less space required. Product Features Made of AISI 316 Stainless Steel High heat exchange efficiency Product Features New Technology BPHE True

More information

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C 1. General The hand-held micro terminal is used for setting the motor parameters of the SILVER C. 2. Installation

More information

Technicians Manual Single Compressor

Technicians Manual Single Compressor Technicians Manual Single Compressor HAC-FF-D WALL PAD Operating Manual Version PCB Version V2.3.5 Version wall pad Version Manual Page 1 Contents 1. Main features 2. Main technical data 3. Wall pad 4.

More information

Reference Guide for Microprocessor Controller

Reference Guide for Microprocessor Controller Document 482641 Microprocessor Controller for Make-Up Air Products Reference Guide for Microprocessor Controller Please read and save these instructions for future reference. Read carefully before attempting

More information

UNIT CONTROLLER 8 (UC8) Troubleshooting guide

UNIT CONTROLLER 8 (UC8) Troubleshooting guide UNIT CONTROLLER 8 (UC8) Troubleshooting guide Date: 27 July 2015 Issue: 2 Page 1 of 18 Contents 1. Cautions... 3 2. Recommended service tool set... 3 3. Recommended set of spare parts... 3 4. Items to

More information

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB Summary 1 CONNECTIONS... 3 1.1 TEMPERATURE PROBES...3 1.2 LOW VOLTAGE DIGITAL INPUTS...3 1.3 LIVE DIGITAL INPUTS...4 1.4 RELAY OUTPUTS...5 2 POWER SUPPLY... 6 3 SERIAL CONNECTIONS... 6 4 SOFTWARE... 7

More information

CONTENTS SAFETY SYMBOLS... 1 GENERAL WARNINGS... 1 MAIN FEATURES... 2 MAIN FUNCTIONS... 2 USER UNIT... 3

CONTENTS SAFETY SYMBOLS... 1 GENERAL WARNINGS... 1 MAIN FEATURES... 2 MAIN FUNCTIONS... 2 USER UNIT... 3 CONTENTS SAFETY SYMBOLS... 1 GENERAL WARNINGS... 1 MAIN FEATURES... 2 MAIN FUNCTIONS... 2 USER UNIT... 3 KEYBOARD...3 ACTIVE KEY COMBINATIONS...4 TURNING THE UNIT ON/OFF...4 CHANGING TEMPERATURE AND FAN

More information

Index. 1. General description of the application Types of units controlled Types of regulation Condensation...

Index. 1. General description of the application Types of units controlled Types of regulation Condensation... LCS pco ADVANCED MICROPROCESSOR USER MANUAL GB Index 1. General description of the application... 4 1.1. Types of units controlled...4 1.2. Types of regulation...4 1.3. Condensation...4 1.4. Safety devices

More information

User manual CLIMATIC 50 - CHILLERS

User manual CLIMATIC 50 - CHILLERS User manual CLIMATIC 50 - CHILLERS Providing indoor climate comfort CL50-CHILLERS-IOM_0808-E INTERNAL USE LENNOX TECHNICIANS VERSION Climatic 50 CHILLER & HEAT PUMP INCLUDING NEOSYS RANGE USER MANUAL Ref:

More information

WRL AFTER SALES SERVICE - REGULATION MANUAL. SOFTWARE UPDATE CAREL μpc vers. up to 2.6.3

WRL AFTER SALES SERVICE - REGULATION MANUAL. SOFTWARE UPDATE CAREL μpc vers. up to 2.6.3 AFTER SALES SERVICE - REGULATION MANUAL WATER / WATER CHILLER WATER COOLED REVERSIBLE CHILLER WATER/WATER HEAT PUMP WRL SOFTWARE UPDATE CAREL μpc vers. up 2.2.2 to 2.6.3 EN edition February 2013 Pag. 2/76

More information

OPERATING INSTRUCTIONS. G214 Software - Version 4

OPERATING INSTRUCTIONS. G214 Software - Version 4 OPERATING INSTRUCTIONS G214 Software - Version 4 Control Panel (G-214 Controller) 1 2 3 4 5 6 7 8 19 9 10 11 12 13 14 15 16 17 18 Control Panel Description 1. Probe shown in Main screen 2. Probe temperature

More information

USER MANUAL. CARRIERrtc electronic control 48/50 EN/EH 38 SZ/SF/NZ/NF

USER MANUAL. CARRIERrtc electronic control 48/50 EN/EH 38 SZ/SF/NZ/NF USER MANUAL CARRIERrtc electronic control 48/50 EN/EH 38 SZ/SF/NZ/NF Translation of the original document 80154, 01.2016 Contents 1. General description....3 1.1. Comunications... 4 1.2. Supervision solutions...

More information

CLIMATIC 60 User manual

CLIMATIC 60 User manual CLIMATIC 60 User manual ECOLEAN NEOSYS Air cooled chiller CL60 AC-CHILLER-IOM-0512-E TABLE OF CONTENTS CLIMATIC 60 AIR COOLED CHILLER CONTROL MANUAL Ref : INTRODUCTION CLIMATIC 60 controller Compatibility

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

Blue Box Epsilon Echos +

Blue Box Epsilon Echos + Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating

More information

C-TRAC3 COMMUNICATION MANUAL FOR. BACnet NOVEMBER 2010 TO JANUARY 2014 USA HEAD OFFICE AND FACTORY

C-TRAC3 COMMUNICATION MANUAL FOR. BACnet NOVEMBER 2010 TO JANUARY 2014 USA HEAD OFFICE AND FACTORY A C-TRAC3 COMMUNICATION MANUAL FOR BACnet NOVEMBER 2010 TO JANUARY 2014 UNIT MODEL NO. UNIT SERIAL NO. SERVICED BY: TEL. NO: CANADIAN HEAD OFFICE AND FACTORY 1401 HASTINGS CRES. SE CALGARY, ALBERTA T2G

More information

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA 99336 www.jmcvr.com 1-509-586-9893 Table of Contents TABLE OF FIGURES...1 OVERVIEW OF THE HRC CAPABILITIES...2 INSTALLATION AND

More information

EasyTronic III MANUAL SERVICE

EasyTronic III MANUAL SERVICE rev.6 EasyTronic III MANUAL SERVICE General characteristics: Power supply 24 Vac ±15% Max consumption at 24Vac 300mA Relay outputs 6 Maximum relay current 8 A res. Serial standard RS232 2 Serial standard

More information

ROOFTOP - HEAT PUMP UNIT

ROOFTOP - HEAT PUMP UNIT ROOFTOP - HEAT PUMP UNIT Operation Manual Applies to Model YNRA R410A WARNINGS This bookles includes operation and maintenance information. Before beginning any procedure, carefully review this information.

More information

Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis

Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis Unit Controller (UC8) Quick Reference Operation and Fault Diagnosis (To be read in conjunction with labels TZ243 (Air-to-Air) & TZ245 (Water-to-Air) Date: 20 October 2015 Issue: 1 Index 1. Introduction...

More information

MCX ELECTRONIC CONTROLLER

MCX ELECTRONIC CONTROLLER WATER - AIR UNITS: CHILLERS y HEAT PUMPS Installer Manual Thank you for trusting the Hitecsa Products. Our company has been offering the market an extended range of specialized units for air conditioning

More information

Reference Guide for Microprocessor Controller

Reference Guide for Microprocessor Controller Document 483586 Microprocessor Controller for Dedicated Outdoor Air System Reference Guide for Microprocessor Controller Please read and save these instructions for future reference. Read carefully before

More information

Air-condensed water chillers and heat pumps YLCA / YLHA 100, 120 and 150

Air-condensed water chillers and heat pumps YLCA / YLHA 100, 120 and 150 Air-condensed water chillers and heat pumps YLCA / YLHA 100, 120 and 150 User manual Ref.: N-40291_EN 1110 Index Index 1 User manual...1 1.1 General description of the unit...2 1.1.1 Models available and

More information

<IMG INFO> 339,95 195, ,35 14,15-1. ENERGY 400 Four Steps Chiller Heat Pump Controller

<IMG INFO> 339,95 195, ,35 14,15-1. ENERGY 400 Four Steps Chiller Heat Pump Controller 339,95 195,85 0 2 89,35 14,15-1 Four Steps Chiller Heat Pump Controller 1 CONTENTS 1 Contents...2 2 How to use this manual...4 3 Introduction...5 3.1 Components...5 3.1.1 Basic Module...5 3.1.2

More information

FINAL USER S INSTRUCTION MANUAL

FINAL USER S INSTRUCTION MANUAL Catalog: AM, AQ, BA, EM Documentation: PGD1 MANUAL Edition: 11 FINAL USER S INSTRUCTION MANUAL pco 5 /pgd DIGITAL CONTROLLER HEAT PUMPS AirMaster, AquaMaster, EasyMaster, BoxAir MASTERTHERM CZ s.r.o. Václavské

More information

NA G µair CONNECT 2

NA G µair CONNECT 2 NA 9.41 G 7-216 µair CONNECT 2 Control manual EN CONTENTS PAGE 1. GENERAL INFORMATION 2 2. COMPONENTS 3 2.1 On the front: 3 2.2 On the rear: 4 3. MENU TREE 7 4. ACCESS LEVEL (menu 8) 1 5. CONFIGURING

More information

RSMV Technical Guide

RSMV Technical Guide RSMV Technical Guide TABLE OF CONTENTS OVERVIEW... 4 Features and Applications... 4 Module Dimensions... 5 INSTALLATION & WIRING... 6 Input Wiring... 6 Suction Pressure Sensor...6 Head Pressure Sensor...6

More information

Networkable Fan Coil Controller Specification and Installation Instructions

Networkable Fan Coil Controller Specification and Installation Instructions Controller Models EFCB10T-OE1 (24Vac / 0 relays) EFCB12T-OE1 (240Vac / 0 relays) EFCB10TU4-OE1 (24Vac / 4 relays) EFCB12TU2-OE1 (240Vac / 2 relays) EFCB12TU4-OE1 (240Vac / 4 relays) TFL Series Thermostat

More information

IC200L Series User manual

IC200L Series User manual IC2L Series User manual DIXELL INDEX 1 GENERAL ADVICE 7 2 GENERAL FEATURES 8 2.1 MAIN FUNCTION 8 3 IC2 L TABLE OF THE FEATURES 1 4 USER INTERFACE 11 4.1 FUNCTION OF THE LEDS OF THE KEY BUTTONS 11 4.2 USE

More information

Standard Instructions For MC-2000/3000/4000 Controllers

Standard Instructions For MC-2000/3000/4000 Controllers Standard Instructions For MC-2000/3000/4000 Controllers Manual Update: 09/12/11 Version: 3.10 1 1 QUICK REFERENCE GUIDE 1.1 NAVIGATING THE DISPLAY Interacting with the AboveAir Technologies unit is accomplished

More information

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort User manual CLIMATIC 2/4 - Controller Providing indoor climate comfort MUL35E-56 9-26 INDEX CONTENTS PAGE INDEX 1 GENERAL DESCRIPTION 2 THE KEYPAD, Climatic 2 3 THE KEYPAD, Climatic 4 4 THE KEYPAD REMOTE

More information

CONTROLS MANUAL For all Innovent and Valent air handling products

CONTROLS MANUAL For all Innovent and Valent air handling products CONTROLS MANUAL For all Innovent and Valent air handling products TABLE OF CONTENTS TABLE OF CONTENTS IMPORTANT INFORMATION Safety information...................................................................................

More information

Simple Self-Diagnosis by Malfunction Code

Simple Self-Diagnosis by Malfunction Code Detail Division 0 Indoor Unit System Others A C E F H J L P U M 7 8 9 External device activated (unified) Protection devices activated (unified) of Miswiring of Shortage of amount ( unit) Shortage of External

More information

Model SRCM Operation

Model SRCM Operation Model SRCM Operation 1 Contents OPERATION... 4 Condition Banner... 6 Condition Banner Touch Screen... 7 Operation... 7 Alarms Cause Condition Banner to Turn Red... 7 Condition Banner Functions... 7 Operating

More information

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408 997-060180-5 Installation Instructions / User s Manual TSTAT0406 and TSTAT0408 4 HEAT 2 COOL DUAL FUEL TSTAT0406 & TSTAT0408-4 WIRE CAPABLE THERMOSTAT (NAXA00201DB Daughter Board sold separately) LEFT

More information

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode R0A (kw-0kw) 0Hz KJR-0B/BE is a human-machine interaction(hmi) used for the communication between chiller operator and main board on the chiller itself. The setting and operation order can be send to the

More information

Power Flame Incorporated

Power Flame Incorporated Power Flame Incorporated SUGGESTED SPECIFICATION FOR MODEL NVC ULTRA LOW NOx GAS BURNERS SUB 9 PPM NOx THE POWER TO MANAGE ENERGY 2001 South 21st Street, Parsons, Kansas 67357 Telephone: 620-421-0480,

More information

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS SCADA INTERFACE INSTRUCTIONS - OPTION 21S - FOR A36D/TPSD SYSTEMS with option 500 and 550. A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE OPTION 21S INSTRUCTIONS This manual is valid for A36D/TPSD Chargers

More information

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422 ºF / º C Rooftop Thermostat Controller Model TRT2422 Description The TRT2422 is a combination controller and thermostat with a built-in scheduler, which is designed for simple and accurate control of single

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit AS* A09LEC AS* A12LEC AO* R09LECN AO* R12LECN R410A CONTENTS 1. DESCRIPTION OF EACH CONTROL

More information

MicroTech Series 200 Centrifugal Chiller

MicroTech Series 200 Centrifugal Chiller Protocol Data Information Packet Version 2.2 Group: Controls Date: March 1999 MicroTech Series 200 Centrifugal Chiller Data Communications Packet for Protocol 2002 McQuay International Revision History

More information

Carbon Monoxide Transmitter

Carbon Monoxide Transmitter Introduction The CO Transmitter uses an electrochemical sensor to monitor the carbon monoxide level and outputs a field-selectable 4-20 ma or voltage signal. The voltage signal may also be set to 0-5 or

More information

Accent User. Version. Rheem. PO Box 146, ABN:

Accent User. Version. Rheem. PO Box 146, ABN: Accent Heat Pump Tariff Controller User Manual Version 1.0 21 Atkinson Street, Liverpool NSW 2170 PO Box 146, Moorebank NSW 1875 ABN: 28 062 383 224 ACN: 062 383 224 Rheem Pool Heating Advisory: 1300 132

More information

EasyTech.One Temperature Controller for Pellet Burner

EasyTech.One Temperature Controller for Pellet Burner EasyTech.One Temperature Controller for Pellet Burner Burner 1 INTRODUCTION... 3 2 ELECTRICAL CONNECTIONS... 3 3 CONTROL PANEL: USE AND FUNCTIONS... 5 3.1 LED... 5 3.2 BUTTONS... 5 3.3 ALARMS... 5 3.1

More information

ReCOOLER HP INSTALLATION AND COMMISSIONING

ReCOOLER HP INSTALLATION AND COMMISSIONING ReCOOLER HP INSTALLATION AND COMMISSIONING Content Page 1. Safety 2 2. Product description 3 Generell information 3 Overview 3 ErP 2016/2218 compliance 4 3. Lifting and transport 7 4. Installation and

More information

DAP III Zone Master User s Guide

DAP III Zone Master User s Guide DAP III Zone Master User s Guide Data Aire, Inc. 230 West BlueRidge Avenue Orange, California 92865 Document Number 600-000-788 March 2010 Revision 1.0 Document # 600-000-788 1 Overview The Data Aire DAP

More information

CLEVER CONTROL Version: V3

CLEVER CONTROL Version: V3 CLEVER CONTROL Version: V3 INSTALLATION AND FUNCTIONING MANUAL USER AND BASIC VERSION Please, read these instructions carefully before attempting installation SECURITY ADVISE SIMBOLS Attention, Danger,

More information

CRIMSON & CRIMSON MAX

CRIMSON & CRIMSON MAX High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial

More information

RSMSD Technical Guide

RSMSD Technical Guide RSMSD Technical Guide www.aaon.com AAON/WattMaster Controls Inc. 8500 NW River Park Drive Parkville, MO 64152 Toll Free Phone: 866-918-1100 PH: (816) 505-1100 FAX: (816) 505-1101 E-mail: mail@wattmaster.com

More information

Siemens RDY2000BN. Start Up Guide

Siemens RDY2000BN. Start Up Guide Siemens RDY2000BN Start Up Guide Answers for infrastructure and cities. What this slide set is about This is a start up guide for the RDY2000BN BACnet Commercial Thermostat. This procedure show how to

More information

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER This manual must be left with owner and should be hung on or adjacent to the boiler for reference. US HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER MODELS CHS-85 through CHS-399 APPENDIX A CONTROLLER

More information

IPC108D - IPC108E (V.2.0)

IPC108D - IPC108E (V.2.0) IPC108D - IPC108E (V.2.0) APPLICATION GUIDE INDEX 1. IMPORTANT RECOMMENDATIONS 6 1.1 PRODUCT DISPOSAL (WEEE) 7 2. GENERALITIES 8 3. AVAILABLE APPLICATION CONFIGURATIONS 8 3.1 MAIN FUNCTIONS 9 4. SUPERVISION

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

I/O ZONE 560/583 USERS GUIDE

I/O ZONE 560/583 USERS GUIDE I/O ZONE 560/583 USERS GUIDE 641-224 641-242 641-237 1 Table of Contents Hot Gas Re-Heat Valve On/Off:... 15 THE ZONE CONTROLLER...4 Modulating Re-Heat Valve:... 16 SPECIFICATIONS...5 CONTROLLER COMPONENTS...6

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information

MCX ELECTRONIC CONTROLLER

MCX ELECTRONIC CONTROLLER WATER - AIR UNITS: CHILLERS y HEAT PUMPS User Manual Thank you for trusting the Hitecsa Products. Our company has been offering the market an extended range of specialized units for air conditioning and

More information

User manual DATALogic2 technical specifications for precision conditioner unit with integrated humidifier

User manual DATALogic2 technical specifications for precision conditioner unit with integrated humidifier DATALogic2 DAT AIR CONTROLLER Manual 201716A02 Issue 09.00 Replaces --.-- User manual DATALogic2 technical specifications for precision conditioner unit with integrated humidifier 1370 Program code: FLAIRMCDZC

More information

ECO N DATE DESCRIPTION OF CHANGE CHG

ECO N DATE DESCRIPTION OF CHANGE CHG Model Number: M21E-24-DIN Description: The product is a loop powered device which controls an unsupervised dual pole output channel suitable to manage 24VAC loads. The M21E-24-DIN is micro-controller operated,

More information

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System Technical Bulletin AD-1272 Code No. LIT-12012477 Issued December 2017 Refer to the QuickLIT website for the most up-to-date version of

More information

Bacnet Room Setpoint & Temp Display. Descriptions. Specifications

Bacnet Room Setpoint & Temp Display. Descriptions. Specifications Descriptions Bacnet Room Setpoint & Temp Display is designed for environment monitoring and controlling in industrial, commercial and other buildings. These transmitters can be used to monitor air temperature

More information

CAREL IR33+ CONTROLLER

CAREL IR33+ CONTROLLER CAREL IR33+ CONTROLLER Programming Instructions The Carel IR33+ controller has a two-level menu system for programming the operation of the case; Level 1 and Level 2 program settings. Unlike IR33, the

More information

GeneSys Air-Cooled Screw Compressor Chiller

GeneSys Air-Cooled Screw Compressor Chiller Operation Manual OM AGSB-5 Group: Chiller Part Number: 331373201 Date: June 2005 Supersedes: OM AGSB-4 GeneSys Air-Cooled Screw Compressor Chiller AGS 230A/B through AGS 475A/B, 60 Hertz AGS 206A/B through

More information

Digital Precise Air Control - DPAC

Digital Precise Air Control - DPAC Digital Precise Air Control - DPAC Mode Enable Sensor Options The temperature of this sensor will determine if the unit is in heating, cooling or vent mode during Occupied operation. The following options

More information

Micro-VPAC IIT LSC - Lift Station Controller. User Manual. Version 1.0.2

Micro-VPAC IIT LSC - Lift Station Controller. User Manual. Version 1.0.2 Micro-VPAC IIT LSC Micro-VPAC IIT LSC - Lift Station Controller User Manual Version 1.0.2 Table of Contents ii CHAPTER: Table of Contents Contents Introduction 5 General 6 Control Description 6 Manual

More information

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1) SY325 Janfire Pellet Burner Boiler for single / double burner management (Version 1.1) TECHNICAL DATA SHEET V1.1 rev.12/2007 Contents INTRODUCTION...3 1 THE CONTROL PANEL...4 2 THE KEYS...4 3 THE LEDS...4

More information

OPERATING MANUAL Enertronic Control System 2

OPERATING MANUAL Enertronic Control System 2 OPERATING MANUAL Enertronic Control System 2 The integrated control system for Lennox chillers in the Ecologic range Manufacturer: Lennox Benelux B.V. Postbus 1028, 3860 BA NIJKERK Watergoorweg 87, 3861

More information

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A900-22007), 120/208/240/1/60, R404A, LT/MT APPS Introduction The superheat controller is designed

More information

Chiller Organizer 2/3

Chiller Organizer 2/3 Chiller Organizer 2/3 OPERATOR S MANUAL Introduction The Chiller Organizer 2/3, is a further evolution of the basic model Chiller Organizer, and it is a microprocessor-based device, which translates with

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

BLAUAIR AUTOMATIC CONTROL SYSTEM

BLAUAIR AUTOMATIC CONTROL SYSTEM BLAUAIR AUTOMATIC CONTROL SYSTEM S30 (KVENT, TH-TUNE) S31 (KVENT) S32 (KVENT, PGDE) EN USER S MANUAL CONTENTS Safety requirements... 3 Purpose... 4 Technical data... 5 Installation and set-up... 6 Control...

More information

1.0 Digital Controller

1.0 Digital Controller Form CP-AHU D19_D21_D22 (11-17) D303072-A Obsoletes Forms CP-Preeva-D21 (1-16) Doc No 303072, CP-Preeva-D19 (1-16) Doc No 303071 Applies to: Preeva, MAPS, MAPS II, RPB, RPBL & SSCBL Series For Air Handler

More information

MicroTech Series-200 Flooded Screw Chiller

MicroTech Series-200 Flooded Screw Chiller Open Protocol Data Infomation Packet Version 1.0 Group: Controls Date: February 1997 MicroTech Series-200 Flooded Screw Chiller Open Protocol Data Communications 2002 McQuay International - C O N F I D

More information

INSTALLATION & USER MANUAL

INSTALLATION & USER MANUAL INSTALLATION & USER MANUAL HC Digital Automatic Humidistat (Y3760) CONTROLS 506808-01 3/2016 Supersedes 6/2011 picture goes here THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE NOTICE

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS CAREL CONTROLLER Programming Instructions The Carel controller has a two-level menu system for programming the operation of the case. Level 1 program settings are the most frequently accessed parameters.

More information

MODBUS RS485 TECHNICAL INSTRUCTIONS

MODBUS RS485 TECHNICAL INSTRUCTIONS MODBUS RS485 TECHNICAL INSTRUCTIONS 2 Modbus RS485 - Technical instruction DESCRIPTION, CONNECTIONS, PRESENTATION, DECIMALS DESCRIPTION RS485 has two connections, A and B. Often there is also a protective

More information

MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: CUSTOMER ORDER NO: PHONE: JCI CONTRACT NO: JOB NAME:

MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: CUSTOMER ORDER NO: PHONE: JCI CONTRACT NO: JOB NAME: Supersedes: 201.28-CL2 (817) Form 201.28-CL2 (1017) MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: PHONE: JOB NAME: CUSTOMER ORDER NO: JCI CONTRACT NO: CHILLER MODEL

More information

High efficiency condensing unit. Installer manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT! High Efficiency Solutions

High efficiency condensing unit. Installer manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT! High Efficiency Solutions High efficiency condensing unit Installer manual NO POWER & SIGNAL CABLES TOGETHER READ CAREFULLY IN THE TEXT! High Efficiency Solutions Content 1. INTRODUCTION 5 2. INITIAL SYSTEM CONFIGURATION 6 2.1

More information