1 SECTION SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section. 1.2 SUMMARY A. Provide labor, materials, and equipment necessary for the complete installation of identifying devices as indicated on the Drawings and specified herein. B. This Section includes the following types of signs: 1. Interior/exterior room name signage. 2. Engraved signs: a. Symbol signage. C. Signage shall be provided to conform to ADA requirements. ADA requirements supersede Technical Specifications in this Section. Manufacturer shall conform to tactile, braille, letter size, and other requirements as may be required by ADA Accessibility Guidelines for Buildings and Facilities, Section 4.30, Signage, and other applicable sections; and State and Local Codes and Regulations. 1.3 SUBMITTALS A. Furnish required shop drawings and other submittals as required for SBBC Facilities selection in accordance with Division 1 requirements (Section ). B. Manufacturer s color charts consisting of actual units or section of units showing the full range of colors available for the following: 1. Magnesium sheet. C. Contractor shall provide a comprehensive list of all room names and numbers for each building space as well as quantities and locations for all other signs specified. D. The Owner shall conduct an in-house review of the signage shop drawings for room numbering and space name allocation for each space to be applied to the signage. E. Indicate location of each sign on shop drawing. Use same designations indicated on drawings. SIGNAGE

2 1.4 QUALITY ASSURANCE A. Design Criteria: The specifications indicate size, type, and dimensional requirements of signs and are based on the specific type and model indicated. Signs by other manufacturers may be considered provided that deviations in dimensions and profiles are minor and do not change the design concept as judged by the Owner. The burden of proof of equality is on the proposer. PART 2 - PRODUCTS 2.1 MANUFACTURERS A. Room Identification Signs 1. Andco Industries Corporation; (800) ; PME 1000 Series 2. APCO Graphics; (404) ; Plaque Series 3. ASI Sign Systems; (214) ; ASI Intouch 4. Best Sign Systems; (800) ; HC300R ADA System Series 2.2 MATERIALS A. Magnesium: Provide magnesium sheet engraving stock with face and core plies in contrasting colors, in finishes and color combinations as selected from the manufacturer's full range of colors. 2.3 COMPONENT CHARACTERISTICS IDENTIFICATION SIGNAGE A. Panel signs shall be 1/8-inch thick, matte acrylic plastic, unframed with eased edges. B. Unless otherwise specified, all room name and number signs shall be as indicated on the Drawings with 3/8 radiused corners. C. Characters 1. Characters shall be upper case sans serif or simple serif typeface and shall have a widthto-height ratio between 3:5 and 1:1. Character stroke-to-width ratio shall be between 1:5 and 1: Characters shall be raised 1/32 and be accompanied by grade 2 Braille transcription in recessed rectangle. 3. Raised characters shall be a minimum of 5/8 in height to a maximum of 2. 1 Paragraph Florida Accessibility Code SIGNAGE

3 D. Pictograms and graphic symbols shall be accompanied by written description placed directly below symbol. E. Characters and background shall be eggshell, matte or other non-glare finish; characters shall adequately contrast with background.2 PART 3 - EXECUTION 3.1 INSTALLATION A. General: Locate sign units and accessories where indicated, using mounting methods of the type described and in compliance with the manufacturer's instructions. 1. Install signs level, plumb, and at the height indicated, with sign surfaces free from distortion or other defects in appearance. B. Wall Mounted Signs: Attach panel signs to wall surfaces using the methods indicated below: 1. Mechanical Fasteners: Use tamperproof stainless steel screws with square head shape placed through predrilled holes. Attach signs with fasteners and anchors suitable for secure attachment to substrate as recommended in writing by sign manufacturer. 2. Signs containing room name and number on one sign shall be installed on the wall adjacent to the latch side of the door and centered 60 AFF (above finished floor). Where there is no wall space to the latch side of the door, signs shall be placed on the nearest adjacent wall The following permanently affixed signs shall be centered at 60 AFF on nearest adjacent wall and printed with raised letters and in Braille. a. Where fire extinguishers are located inside student-occupied spaces, a sign of white raised letters on a red background reading FIRE EXTINGUISHER INSIDE shall be located outside the space. 4 b. Toilet room signs shall contain appropriate symbol depicting International Men/Women Symbol at each toilet room. 2 Paragraph Florida Accessibility Code 3 Paragraph Florida Accessibility Code 4 Paragraph (13) (b) Section 423 FBC SIGNAGE

4 3.2 CLEANING AND PROTECTION A. At completion of the installation, clean soiled sign surfaces in accordance with the manufacturer's instructions. Protect units from damage until acceptance by the Owner. INTERIOR SIGNAGE SCHEDULE INTERIOR SIGANGE # ROOM SIGN TYPE COMMENTS 100 LOBBY COMMUNITY ROOM A 101A A/V CL PUBLIC RR C 103 ALCOVE ADMIN SEC B 105 COPY/PRINT FIRE CHIEF OFFICE B 106A CL ADMIN CONFERENCE A 108 DEP CHIEF OFFICE B 108A CL FLEX OFFICE B 110 DIST. CHIEF OFFICE B 111 D CHIEF BUNK LT OFFICE B 113 WATCH OFFICE B 114 HALL RR/SHR C 116 RR/SHR C 117 BUNK BUNK BUNK BUNK BUNK BUNK BUNK BUNK HALL LAUNDRY D 127 COMMAND STORAGE D 128 JANITOR D 129 PLANS REVIEW/ STORAGE FIRE INSPECTOR B 131 OFFICE SUPPLY D 132 RESTROOM C 133 CENTRAL FILE STORAGE D 134 ADMIN BREAK HALL LOGISTICS/EQMT SUPPLY D 137 HVAC D 138 TELE D 139 ELEC D 140 PHYS AGILITY D SIGNAGE

5 140A MECH D 141 HALL KITCHEN D 143 P1-144 P2-145 P3-146 EMS SUPPLY D 147 DINING DAYROOM HALL APPARATUS BAY MAINT SHOP D 152 LOGISTICS/EQMT SUPPLY D 153 SCBA TANK STORAGE D 154 DECON D 155 BUNKER GEAR STORAGE D 156 HALL HALL RESTROOM C END OF SECTION SIGNAGE

6 DRAWN BY: SAGE, LYNDZEE ADA SIGN PLAN DATE: 08 JULY 2016

7 SECTION CORNER GUARDS PART 1- GENERAL 1.1 SECTION INCLUDES A. Corner Guard, Stainless Steel B. Corner Guard End Wall, Stainless Steel 1.2 SUBMITTALS A. Comply with requirements of Section Submittals. B. Product data: Submit manufacturer s product data. C. Shop drawing: Submit shop drawings showing components, dimensions, anchorage details. D. Samples: Submit for approval 12 (304.8mm) long sample for each model and color specified, including end caps and corner units. E. Test reports: Submit manufacturer s test reports and certification indicating compliance with applicable ADA and building code requirements 1.3 QUALITY ASSURANCE A. Single Source Responsibility: Furnish all wall protection system components from a single source. B. Manufacturer: A firm regularly engaged in the manufacture of wall protection system components similar to those specified. C. Installer: A firm with at least 3 years of successful experience in the installation of wall protection systems similar to those specified. 1.4 DELIVERY, STORAGE AND HANDLING A. Delivery: Deliver materials to site in manufacturer s original, unopened containers and packaging with labels clearly indicating manufacturer and material. B. Storage: Store materials indoors in a clean, dry area protected from damage and in accordance with manufacturer s instructions. C. Handling: Protect materials during handling and installation to prevent damage PART 2- PRODUCTS 2.1 MANUFACTURER Basis of Design: Nystrom Inc rd Ave North Minneapolis, MN PH: FX: A. Alternate manufacturers: 1. C/S Group, 2. Korogard B. Products are subject to comply with requirements specified. Provide either the named product or a comparable product by another manufacturer. See performance spec section Substitution Procedures. CORNER GUARDS

8 2.2 CORNER GUARD, STAINLESS STEEL, SURFACE MOUNT A. Nystrom model CGSS Surface mount stainless steel corner guard with variable wings 1. Dimensions a. Wing size: 1 minimum to customer specified maximum b. Corner angle type: 90 degree standard 2. Material 1. Specify other (135 degree) 3- EXECUTION 3. Mounting: 3.1 EXAMINATION a. Stainless Steel Type #304, 16 Gauge Stainless Steel, Satin #4 Finish with rounded edged and protective coating a. Mechanically fastened with screws PART A. Verify by examination that wall surface is acceptable to receive the specified bumper guard. Notify the Architect in writing if wall surfaces are not acceptable. Do not begin installation until unacceptable conditions have been corrected. 3.2 INSTALLATION A. Install corner guards to wall securely in accordance with manufacturer s written instructions. B. Install corner guards accurately in location, alignment, and elevation. C. Provide horizontal steel stud back up in drywall stud cavity to accept fasteners. END OF SECTION CORNER GUARDS

9 SECTION FIRE PROTECTION CABINETS PART 1 - GENERAL 1.1 SUMMARY A. Section includes fire-protection cabinets for portable fire extinguishers. 1.2 ACTION SUBMITTALS A. Product Data: For each type of product. B. Shop Drawings: For fire-protection cabinets. 1.3 CLOSEOUT SUBMITTALS A. Maintenance data. 1.4 COORDINATION A. Coordinate size of fire-protection cabinets to ensure that type and capacity of fire extinguishers indicated are accommodated. B. Coordinate sizes and locations of fire-protection cabinets with wall depths. 1.5 SEQUENCING A. Apply vinyl lettering on field-painted fire-protection cabinets after painting is complete. PART 2 - PRODUCTS 2.1 PERFORMANCE REQUIREMENTS A. Fire-Rated Fire-Protection Cabinets: Listed and labeled to comply with requirements in ASTM E 814 for fire-resistance rating of walls where they are installed. FIRE PROTECTION CABINETS

10 2.2 FIRE-PROTECTION CABINET A. Cabinet Type: Suitable for fire extinguisher, Semi recessed. 1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to the following: a. JL Industries, Inc.; a division of the Activar Construction Products Group. b. Larsens Manufacturing Company. c. Modern Metal Products, Division of Technico Inc. d. Potter Roemer LLC. B. Cabinet Construction: Rate cabinet per wall rating. 1. Fire-Rated Cabinets: Construct fire-rated cabinets with double walls fabricated from inch- thick cold-rolled steel sheet lined with minimum 5/8-inch- thick fire-barrier material. Provide factory-drilled mounting holes. C. Cabinet Material: stainless steel sheet D. Semi-recessed Cabinet: One-piece combination trim and perimeter door frame overlapping surrounding wall surface with exposed trim face and wall return at outer edge (backbend). 1. Rolled-Edge Trim: 2-1/2-inch backbend depth. E. Cabinet Trim Material: stainless steel sheet F. Door Material: stainless steel sheet G. Door Style: center glass panel with frame H. Door Glazing: Tempered float glass (clear). I. Door Hardware: Manufacturer's standard door-operating hardware of proper type for cabinet type, trim style, and door material and style indicated. J. Accessories: 1. Break-Glass Strike: Manufacturer's standard metal strike, complete with chain and mounting clip, secured to cabinet. 2. Door Lock: Cam lock that allows door to be opened during emergency by pulling sharply on door handle. 3. Identification: Lettering complying with authorities having jurisdiction for letter style, size, spacing, and location. Locate as indicated. FIRE PROTECTION CABINETS

11 K. Materials: a. Identify fire extinguisher in fire-protection cabinet with the words "FIRE EXTINGUISHER." 1) Location: Applied to door. 2) Application Process: Silk Screen. 3) Lettering Color: White. 4) Orientation: Horizontal. 1. Stainless Steel: ASTM A 666, Type 304. a. Finish: No. 4 directional satin finish. 2. Tempered Float Glass: ASTM C 1048, Kind FT, Condition A, Type I, Quality q3, 3 mm thick, Class 1 (clear). 3. Tempered Break Glass: ASTM C 1048, Kind FT, Condition A, Type I, Quality q3, 1.5 mm thick. 2.3 FABRICATION A. Fire-Protection Cabinets: Provide manufacturer's standard box (tub) with trim, frame, door, and hardware to suit cabinet type, trim style, and door style indicated.execution 2.4 INSTALLATION A. Prepare recesses for semi-recessed fire-protection cabinets as required by type and size of cabinet and trim style. B. Install fire-protection cabinets in locations and at mounting heights indicated or, if not indicated, at heights acceptable to authorities having jurisdiction. C. Fire-Protection Cabinets: Fasten cabinets to structure, square and plumb. D. Identification: Apply vinyl lettering at locations indicated. E. Adjust fire-protection cabinet doors to operate easily without binding. Verify that integral locking devices operate properly. END OF SECTION FIRE PROTECTION CABINETS

12 SECTION FIRE EXTINGUISHERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes portable, hand-carried fire extinguishers and mounting brackets for fire extinguishers. 1.2 ACTION SUBMITTALS A. Product Data: For each type of product. 1.3 INFORMATIONAL SUBMITTALS A. Warranty: Sample of special warranty. 1.4 CLOSEOUT SUBMITTALS A. Operation and maintenance data. 1.5 COORDINATION A. Coordinate type and capacity of fire extinguishers with fire-protection cabinets to ensure fit and function. PART 2 - PRODUCTS General: Provide fire extinguishers for each cabinet and other locations indicat- ed, in colors and finishes selected by Architect from manufacturer's standard, that comply with authorities having jurisdiction. A. Multipurpose Dry Chemical Type: UL-rated 2-A:10:B:C, 5-lb nominal capacity, in enameled steel container. B. Wet Chemical K Class Type: UL-rated 2A:1B:K, 6 liter nominal capacity, in enabled steel container. FIRE EXTINGUISHERS

13 2.1 PERFORMANCE REQUIREMENTS A. NFPA Compliance: Fabricate and label fire extinguishers to comply with NFPA 10, "Portable Fire Extinguishers." B. Fire Extinguishers: Listed and labeled for type, rating, and classification by an independent testing agency acceptable to authorities having jurisdiction. 2.2 PORTABLE, HAND-CARRIED FIRE EXTINGUISHERS A. Fire Extinguishers: Type, size, and capacity for each fire-protection cabinet and mounting bracket indicated. B. Manufacturers: 1. J.L. Industries. 2. Larsen's Manufacturing Co. 3. Modern Metal Products by Muckle. 4. Potter-Roemer, Inc. 5. Samson Metal Products, Inc. 1. Instruction Labels: Include pictorial marking system complying with NFPA 10, Appendix B, and bar coding for documenting fire-extinguisher location, inspections, maintenance, and recharging. A. Multipurpose Dry Chemical Type: UL-rated 2-A:10:B:C, 5-lb nominal capacity, in enameled steel container. B. Wet Chemical K Class Type: UL-rated 2A:1B:K, 6 liter nominal capacity, in enabled steel container. 2.3 MOUNTING BRACKETS 2.4 Retain this article if mounting brackets separate from fire-protection cabinets are required. A. Mounting Brackets: Manufacturer's standard galvanized steel, designed to secure fire extinguisher to wall or structure, of sizes required for types and capacities of fire extinguishers indicated, with plated or White baked-enamel finish. B. Identification: Lettering complying with authorities having jurisdiction for letter style, size, spacing, and location. Locate as indicated by Architect. 1. Identify bracket-mounted fire extinguishers with the words "FIRE EXTINGUISHER" in red letter decals applied to mounting surface. a. Orientation: Vertical FIRE EXTINGUISHERS

14 PART 3 - EXECUTION 3.1 INSTALLATION A. Examine fire extinguishers for proper charging and tagging. 1. Remove and replace damaged, defective, or undercharged fire extinguishers. B. Install fire extinguishers and mounting brackets in locations indicated and in compliance with requirements of authorities having jurisdiction. 1. Mounting Brackets: 54 inches above finished floor to top of fire extinguisher. C. Mounting Brackets: Fasten mounting brackets to surfaces, square and plumb, at locations indicated. END OF SECTION FIRE EXTINGUISHERS

15 SECTION RANGE HOOD FIRE EXTINGUISHER PART 1 - GENERAL A. GUARDIAN MODEL #G300A AUTOMATIC FIRE EXTINGUISHING SYSTEM FOR RESIDENTIAL RANGE TOP PROTECTION B. SCOPE: This specification includes minimum requirements for fire extinguishing systems which discharge chemical from fixed nozzles by means of expellant gas. It contains essentials necessary to ensure compliance with the National Fire Protection Association (NFPA) standards and Underwriters Laboratories Incorporated (U.L.). C. PURPOSE: This specification is prepared for the use and guidance of those charged with the purchasing, designing, and approving fire extinguishing systems pre-engineered for residential kitchen range top protection. D. DEFINITIONS: For the purpose of clarification, the following general terms used with special technical meanings in this specification are defined: 1. WET CHEMICAL: Normally a solution of water and potassium carbonate-based chemical, potassium acetate-based chemical or a combination thereof, which forms an extinguishing agent. 2. LISTED: Equipment or materials included in a list published by Underwriters Laboratories Incorporated (U.L.) 3. SHALL: Indicates a mandatory requirement. 4. SHOULD: Indicates a recommendation or that which is advised but not required. 5. APPLIANCE: For the purpose of this specification, appliance means a residential type kitchen range supplied by gas or electricity to power and heat range top burners. E. GENERAL DESCRIPTION: The fire extinguishing system shall be capable of detecting a cooking grease fire originating on the range top, extinguish the fire, and prevent reignition, while at the same time, shut-off the gas or electric supply to surface elements on the kitchen range top. Each system shall be provided with a means to distribute the chemical agent, fire detection components, container for storing the chemical, valve assembly with pressure gauge, enclosure assembly for container, and appliance shut-off device. These components shall be provided factory assembled and ready for installation and installed in accordance with an approved owner's manual. F. CERTIFICATION: The fire extinguishing systems shall have a current U.L. listing under the category "Residential Range Top Fire Protection" in the most recent Fire Protection Equipment Directory (FPED). G. CHEMICAL AGENT: 1. WET CHEMICAL: Shall conform to the requirements of National Fire Protection Association (NFPA) Standard No. 17A for Wet Chemical Fire Extinguishing Systems. RANGE HOOD FIRE EXTINGUISHER

16 PART 2 - SYSTEM COMPONENTS: A. SYSTEM ENCLOSURE: The system enclosure shall consist of the pressurized extinguisher cylinder with wet chemical fire suppressant, central processing unit control board with terminal block connections, electronic release valve, cylinder pressure gauge, enclosure base, and enclosure cover. Operation of the extinguisher unit is controlled by the supervised electronic control panel, which is battery powered. Detection is initiated through the heat sensors, activating the alarm and the extinguisher. The electric or gas shutdown devices can either be sonically operated by the control panel, or hardwired to the central processing unit control board. B. CYLINDER AND VALVE ASSEMBLY: The extinguisher cylinder and valve assembly shall be provided fully charged with chemical and pressurized with dry nitrogen in accordance with listed requirements. A pressure gauge attached to the valve assembly shall be positioned to allow visual inspection when installed within a kitchen cabinet. Maximum allowable height of container (including the enclosure assembly) shall not exceed 12 inches. The container and valve assembly shall be of the serviceable type and provide maintenance requirements synonymous with that required for portable hand-held fire extinguishers, according to National Fire Protection Association (NFPA) Standard 10. The container and valve assembly shall be provided factory assembled to the enclosure. Assembly shall include a pre-mounted CPU control board for the appliance shut-off device and necessary attachment for the Fire Detection Unit. The complete extinguisher cylinder and valve assembly shall be installed in a protected area above the range hood (normally, kitchen cabinets). Installations which expose extinguisher cylinder and valve assembly to direct cooking heat and grease will not be accepted. C. CENTRAL PROCESSING UNIT CONTROL BOARD: The CPU control board is housed/attached inside the system enclosure. The control board's circuitry is powered by a 9V DC battery and has the following features: D. SUPERVISED CIRCUITRY: The audible 106DB alarm on the CPU control board will "alarm" to warn of possible trouble in the electronic circuitry including the heat sensors, if there is an open circuit. E. SYSTEM OPERATION LIGHT: The red "power" light will blink approximately every 45 seconds to confirm the system is operating. F. AUDIBLE ALARM: The system 106DB alarm is designed to continuously sound once the system has been activated by a stovetop fire. G. LOW BATTERY WARNING: The audible alarm on the CPU control board will "chirp" approximately every 45 seconds when a low battery condition exits. If this condition exists, 9V DC battery must be replaced immediately to insure proper system operation. H. AUXILIARY OUTPUTS: Can be connected to automatic telephone dialers, monitored security alarm systems or other warning/protective equipment. Auxiliary outputs provide one (1) second impulses to activate above items. These connections are rated at 5 AMP at 250V AC. I. TEMPERATURE ACTIVATED SENSOR ASSEMBLY: The sensor assembly shall consist of two (2) metal housed detector assemblies containing diode-type heat sensors, affixed to the side of the magnetic nozzle bases, and connected to the CPU control board with two (2) different wire lengths. RANGE HOOD FIRE EXTINGUISHER

17 J. DISTRIBUTION ASSEMBLY: The distribution assembly shall consist of two (2) Teflonlined stainless steel braided hoses and two (2) magnetic based adjustable nozzle assemblies. The use of copper tubing shall not be accepted. Hose and nozzles shall comply with NFPA Standard No. 17A for Wet Chemical Extinguishing Systems and shall have been investigated by Underwriters Laboratories, Inc. (U.L.) and listed for this service. K. APPLIANCE NOZZLES: Wet System: Appliance nozzles shall be constructed of brass. Appliance nozzles with painted surfaces shall not be accepted. Appliance nozzles shall not extend below the lowest component of the range hood. Design shall provide equal distribution of chemical agent and allow chemical to flow effectively with low velocity to avoid splattering of burning grease. L. APPLIANCE SHUTDOWN DEVICE: Each system shall be provided with a listed device to automatically shut-off the gas or electric supply to surface burners on the kitchen range top upon activation of the alarm from the fire detection unit. The gas or electric supply shall remain "off" until manually reset. Electrical power cut-off to kitchen range hood exhaust fan shall not be required for Underwriters Laboratories Incorporated (U.L.) listed extinguishing systems. M. SONIC ACTIVATED ELECTRIC RANGE SHUT-OFF: All wiring, fittings, and connections shall comply with NFPA Standard 70 and local codes and ordinances. Each electrically supplied kitchen range appliance shall be provided with a U.L. Listed wireless sonic activated shut-off. The electric stove sonic shut-off unit continuously monitors for an alarm from the central processing unit control board. The alarm sounds to activate the sonic shut-off unit. Once activated, all electrical power to the stove is shut off, and must be reset. N. SONIC ACTIVATED GAS RANGE SHUT-OFF: Each gas supplied kitchen range appliance shall be provided with a U.L. Listed or U.L. Recognized Components as follows: 1. VALVE: Coil rated 9V DC, 1.4W 2. PRINTED WIRING BOARD: The sonic gas shut-off unit continuously monitors for an alarm from the central processing unit control board. The alarm sounds to activate the sonic gas shut-off unit. Once activated, the gas valve shall remain in the closed position and shall require manual reset by depressing the reset button located on the bottom of the valve. 3. The sonic gas shut-off unit is powered with a 9V DC battery. Internal circuitry monitors the condition of the battery and will cause the alarm to "chirp" approximately every 45 seconds when a low battery condition exists. PART 3 - OWNER'S MANUAL: A. Each system shall be provided with a comprehensive owner's manual that shall contain procedures for post clean-up, parts identification, complete wiring diagram, system installation with pictorials for step-by-step procedures, system limitation, inspection and maintenance requirements. Servicing/recharging procedures shall also be contained in the owner's manual. RANGE HOOD FIRE EXTINGUISHER

18 PART 4 - OPTIONAL EQUIPMENT: A. MANUAL REMOTE PULL STATION: Device shall be U.L. Listed or Recognized Component supplied complete with wire leads and listed with the residential system. B. REMOTE AUDIBLE ALARM: Where a cabinet design or material thickness prohibits the DB (loudness) level from activating the shut-off a remote 106 DB alarm shall be installed under the range hood. Only a remote alarm listed and compatible with the central processing unit control board shall be used. C. AC/DC WALL PLUG IN POWER SUPPLY: Where a constant 9-volt power source is required an AC/DC wall plug in transformer can be supplied. Only a U.L. Listed AC/DC wall plug in power supply that has been tested and listed with the central processing control board shall be used. END OF SECTION RANGE HOOD FIRE EXTINGUISHER

19 SECTION ALUMINUM WALKWAY COVERS PART 1 GENERAL DESCRIPTION OF WORK: Furnish and install the aluminum walkway covers where shown and detailed on the drawings. SUBMITTALS: In accordance with Division 1, Submittals, of this specification provide shop drawings prepared for this work, material samples, color samples and product data. QUALITY ASSURANCE: Shop drawings shall identify all materials and components with details for installation for this work. Live and dead loads affecting this structure shall be clearly shown. All product members shall be sized to meet ASCE 7-02, 125 mph min. wind speed, 1.15 importance factor and other code requirements for lateral, dead and live loads per Florida Building Code. All drawings submitted by the manufacturer shall be signed and sealed by a Florida registered structural engineer. Manufacturer and installer shall submit evidence that for 5 years minimum they have been in business to manufacturer and install fixed aluminum walkway covers. PART 2 - PRODUCTS APPROVED MANUFACTURER: The drawings and specifications are based on products manufactured by DITTMER Architectural Aluminum of Winter Springs, Florida. Similar or better products of another manufacturer will be considered prior to bid date. Other manufacturers shall submit a letter of request for consideration and product literature in accordance with Section 01600, Products and Substitutions. GENERAL: Aluminum Walkway Cover or Canopy shall be entirely of anodized aluminum extrusions. Understructure shall consist of heli-arc welded one-piece rigid bents and the deck of interlocking anodized aluminum extrusions. The structure shall be capable of sustaining severe icing, hail, hurricane winds and being walked upon for inspections. MATERIALS: All sections shall be 6063 alloy heat-treated to a T-6 temper. Deck screws shall be type 18-8 stainless steel, sealed with neoprene "O" ring beneath stainless steel; trim rivets may be aluminum. A dip-coat of clear acrylic enamel shall insulate column ends from electrolytic reaction with grout. Grout shall be 3:1 Portland cement to masonry sand, 2000# compressive strength. INTERNAL DRAINAGE: Water flow is directed from deck to beams and columns for discharge out at ground level. BENT CONSTRUCTION: Anodized beams and columns shall be heli-arc welded into rigid, one-piece units in the manufacturer's plant. Column ends shall be pierced to "key" grout to bent for maximum uplift protection. ALUMINUM WALKWAY COVERS

20 ROOF DECK: Extruded, self-flashing deck sections interlock into a composite unit, spanning double-bays for superior loading. Deck shall be staked into a camber sufficient to off-set deadload deflection and to cause positive drainage on spans over 15'0". Staking shall consist of an abrupt local deformation of deck-lock metal, each stake having a shear value in excess of 350# and shall occur as detailed. FINISH: Shall be equal to a Kynar 500 on exposed components. Concealed areas may be baked enamel. All colors shall be selected by the Architect from the full range of colors available, standard and premium grades. PRODUCTS: Top deck shall be equal to DITTMERS "Standard 60". Fascia shall be equal to DITTMERS, F-5 Fascia, 5" with tie-backs. Beam and column: "U" BENT model. GENERAL: PART 3 - EXECUTION The manufacturer/installer shall visit the site to confirm the contractors schedule and readiness to undertake installation of this work. Once the manufacturer/installer commences with the work, it shall be understood that he accepts the conditions of the site. The manufacturer/installer shall verify all dimensions for the installation in the field. ERECTION: Sleeves or block-outs shall be furnished by the manufacturer/installer and set by General Contractor. Bents shall be aligned prior to grouting; downspout column interiors shall be grouted to lower edge of "weephole"; deflectors shall be installed after grouting. All deck ends at beam joints shall be capped. Butt and miter joints shall be executed in a workman like manner. CLEAN-UP: Manufacturer/installer shall clean-up the installation and work site on a daily basis. END OF SECTION ALUMINUM WALKWAY COVERS

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers. SECTION 10 44 13 - FIRE-PROTECTION SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES SECTION 105200 - FIRE-PROTECTION SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SECTION FIRE EXTINGUISHER CABINETS

SECTION FIRE EXTINGUISHER CABINETS SECTION 104413 FIRE EXTINGUISHER CABINETS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II SECTION 104413 FIRE EXTINGUISHER CABINETS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017 SECTION 104413 - FIRE PROTECTION CABINETS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work.

B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work. PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information

ADDENDUM #1: MODIFICATIONS AND ADDITIONS TO CONTRACT DOCUMENTS

ADDENDUM #1: MODIFICATIONS AND ADDITIONS TO CONTRACT DOCUMENTS Annex Laundry and Shower Alterations ADDENDUM #1 March 7, 2019 ADDENDUM #1: MODIFICATIONS AND ADDITIONS TO CONTRACT DOCUMENTS A. Invitation to Bid - Call for Bids has been modified as follows: 1. Notice

More information

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials. B B11.0 DIVISION 08 - OPENINGS SECTION 08 17 00 INTEGRATED DOOR OPENING ASSEMBLIES Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements. Add section numbers and

More information

A. Provide products and workmanship in accordance to: (Where applicable)

A. Provide products and workmanship in accordance to: (Where applicable) SECTION 10 00 00 SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section includes: 1. Fire Extinguishers, Cabinets, and brackets. 2. Wire Shelving. 3. Coat Racks. B. Related Sections: Documents relating to the

More information

ARCHITECTURAL SPECIFICATIONS

ARCHITECTURAL SPECIFICATIONS 1 B9.1 In Ground Page 1 of 6, Aug 12 DIVISION 08 - OPENINGS SECTION 08 71 13 POWER DOOR OPERATORS Specifier Note: Coordinate and edit articles and paragraphs below to suit project requirements. Add section

More information

DIVISION 10 SPECIALTIES

DIVISION 10 SPECIALTIES DIVISION 10 SPECIALTIES 11/11 SECTION 10 21 13.16 PLASTIC LAMINATE TOILET COMPARTMENTS PART 1 - GENERAL 1.01 SECTION INCLUDES Plastic laminate toilet compartments, urinal screens, head rail braced. 1.02

More information

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings. DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS

More information

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening. DIVISION 8 OPENINGS SECTION 08 33 23 PART 1 GENERAL 1.1 SECTION INCLUDES A. Overhead coiling counter fire doors. 1.2 RELATED SECTIONS A. Section 05500 - Metal Fabrications: Support framing and framed opening.

More information

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES SECTION 10 00 00 - SPECIALTIES 10 28 12 - TOILET PARTITIONS: Owner Preferences: Solid core phenolic, polymer based solid surfacing, and solid plastic toilet compartment and screen systems. No Stainless

More information

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC SECTION 08 35 13.23 ACCORDION FOLDING FIRE DOORS PART 1 GENERAL 1.01 SUMMARY OF WORK A. Division 0 and 1, as indexed, apply to this section. B. Furnish and install

More information

Shop Drawings: For fire protection cabiaets, lnclode plans, elevations, sections, details, and attachments to other work.

Shop Drawings: For fire protection cabiaets, lnclode plans, elevations, sections, details, and attachments to other work. SECTION 104413 - PART 1 - GENERAL 1,1 RELATED DOCUMENTS Drawings and general provisions of the Contract, inclnding General and Snpplementary Conditions and Division 01 Specification Sections, apply to

More information

SECTION COMMERCIAL-KITCHEN HOODS

SECTION COMMERCIAL-KITCHEN HOODS SECTION 23 38 13 COMMERCIAL-KITCHEN HOODS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Delete other items or paragraphs in the section that are not applicable and renumber

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-21 21 03.00 10 February 2009) ---------------------------------- Preparing Activity: USACE Superseding UFGS-21 21 03.00 10 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

A. Section Includes: Fire extinguishers and cabinets including necessary accessories.

A. Section Includes: Fire extinguishers and cabinets including necessary accessories. SECTION 10522 FIRE EXTINGUISHERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Fire extinguishers and cabinets including necessary accessories. B. Related Sections: 1. 09900 - Painting 2. 10400 - Identifying

More information

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL SECTION 21 13 16 DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR SECTION 08734 COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Overhead

More information

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant. SECTION 218800 - FIRE PROTECTION 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 230000, MECHANICAL GENERAL CONDITIONS, and Section 230050, SEISMIC PROTECTION are a part of this

More information

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER SECTION 08 3493 AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Smoke detector-activated, vertical closing fire barrier conveyor system closure.

More information

Linear Floor Heaters

Linear Floor Heaters Linear Floor Heaters The Price Linear Floor Heater family provides ultimate flexibility in terms of style, performance, and ease of installation. Using room-side heat virtually eliminates the requirement

More information

SECTION AIR DUCT ACCESSORIES

SECTION AIR DUCT ACCESSORIES SECTION 23 33 00 AIR DUCT ACCESSORIES PART 1 - GENERAL 1.1 SUMMARY A. Section includes back-draft dampers, combination fire-and-smoke dampers, duct access doors, fire dampers, smoke dampers, volume control

More information

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System. SMOKE GUARD SYSTEM MODEL 600 REV. 3 SPECIFICATION Smoke Guard, Inc 287 Maple Grove Boise, ID 83704 Toll Free: 800.574.0330 Fax: 208.639.7851 e-mail: info@smokeguard.com website: http://www.smokeguard.com/

More information

FIRE & LIFE SAFTEY STANDARD

FIRE & LIFE SAFTEY STANDARD Title: Effective Date: 01/01/14 Revised Date: 1/1/14 Code References: Title 16, Chapter 16.16 of the Roseville Municipal Code, NFPA 72 Note: This standard is a summary of Fire Department clarifications

More information

B. Section Identification for Fire Suppression Piping and Equipment.

B. Section Identification for Fire Suppression Piping and Equipment. SECTION 211300 - FIRE SUPPRESSION SPRINKLERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.2 RELATED

More information

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete wet chemical automatic fire suppression system for the exhaust hood, including necessary

More information

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION WET-PIPE SPRINKLER SYSTEMS SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SCOPE OF WORK A. Design, installation and testing shall be in accordance with NFPA 13 except for specified exceptions. B. The demolition

More information

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System. SMOKE GUARD SYSTEM MODEL 400 SPECIFICATION Smoke Guard, Inc. 287 N. Maple Grove Boise, ID 83704 Toll Free: 800.574.0330 Fax: 208.376.1600 e-mail: info@smokeguard.com website: http://www.smokeguard.com/

More information

1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for detention furniture.

1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for detention furniture. SECTION 125500-WALL BED SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS SECTION 08331 OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft

More information

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM PART 1 GENERAL 1.01 SUMMARY SECTION 15371 KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM A. Section Includes: A complete automatic fire suppression system for the exhaust hood, including necessary accessories.

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

SECTION Overhead Coiling Doors

SECTION Overhead Coiling Doors SECTION 08 33 00 Overhead Coiling Doors To display hidden notes to specifier, select tools/ options/ view/ hidden text. GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract,

More information

SECTION AIR DOORS

SECTION AIR DOORS SECTION 23 34 33 AIR DOORS Berner Series VSA air doors are designed for openings up to 12 ft for environmental separation and up to 10 ft for insect control. Berner Series VSB air doors are designed for

More information

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses PART 1 - GENERAL 1.1 SCOPE A. Through Class III Commodity Classification, up to 12.2m of single, double or multiple row rack storage, up to 14.6m building height (VanQuish Fire Sprinkler System). Cartoned

More information

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System. SMOKE GUARD SYSTEM MODEL 200 SPECIFICATION Smoke Guard inc. 287 N. Maple Grove Boise, ID 83704 Toll Free: 800.574.0330 Fax: 208.639.7851 e-mail: info@smokeguard.com website: http://www.smokeguard.com/

More information

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR SECTION 08 71 13 LOW ENERGY AUTOMATIC OPERATORS Specifier Note: Coordinate and edit articles

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-23 83 00.00 20 (April 2006) -------------------------------- Preparing Activity: NAVFAC Replacing without change UFGS-15768N (September 1999) UNIFIED FACILITIES GUIDE

More information

Consult the manufacturer for assistance in editing this guide specification for specific Project applications where necessary.

Consult the manufacturer for assistance in editing this guide specification for specific Project applications where necessary. This guide specification was prepared utilizing 3-part format recommended by the Construction Specifications Institute (CSI), and generally incorporates recommendations from their SectionFormat /Page Format,

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2017 SECTION 10 2800 - TOILET, BATH, AND LAUNDRY ACCESSORIES GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

FIRE SUPPRESSION SPRINKLER SYSTEM

FIRE SUPPRESSION SPRINKLER SYSTEM PART 1 GENERAL 1.01 DESCRIPTION A. The provisions of the General Requirements, Supplementary Requirements, and Division 1 apply to the plumbing work specified in this Division. B. The requirements of this

More information

Architectural Specification Sheet

Architectural Specification Sheet Architectural Specification Sheet 1. General 1.01 Summary A. commercial low energy automatic swing door operator that consists of: -Aluminum housing -Electro-mechanical motor -Operator control assembly

More information

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions: SECTION 21 13 13 WET-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

Design & Construction Standards, Revised January

Design & Construction Standards, Revised January PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of The University of Texas at Austin for fire-extinguishing systems other than water-based fire suppression systems.

More information

SECTION INCLINE WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION INCLINE WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text. SECTION 14 42 13 INCLINE WHEELCHAIR LIFTS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Indoor inclined platform wheelchair lifts.

More information

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

A U TO S M O K E. Model AUTO SMOKE FIRE SHUT Flat Slats Fire Shut Rolling Doors

A U TO S M O K E. Model AUTO SMOKE FIRE SHUT Flat Slats Fire Shut Rolling Doors Model AUTO SMOKE Flat Slats Fire Shut Rolling Doors NOTE: For specifications, architects must choose from a variety of options. The standard choice will be shown first in plain text followed by the options

More information

SECTION OVERHEAD COILING FIRE DOORS

SECTION OVERHEAD COILING FIRE DOORS SECTION 08331 OVERHEAD COILING FIRE DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click on round Windows logo in top left corner,

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018 SECTION 10 2800 - TOILET, BATH, AND LAUNDRY ACCESSORIES GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01

More information

SECTION GYPSUM PLASTER

SECTION GYPSUM PLASTER SECTION 09210 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation for support of gypsum plaster used as a finish for partitions and ceilings

More information

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No. SECTION 22 63 13 GAS PIPING FOR LABORATORY AND HEALTHCARE FACILITIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL SECTION 1 - GENERAL CONDITIONS I. SCOPE: This specification outlines the requirements for a Fike Micromist Water Mist Fire Suppression System with automatic detection and control. The work described in

More information

D. Reference Standards (Utilize latest editions available):

D. Reference Standards (Utilize latest editions available): 1.01 Scope of Standard A. This standard provides general requirements of The Sam Houston State University for fireextinguishing systems other than water-based fire suppression systems. This document is

More information

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

SECTION (13900) - FIRE SUPPRESSION SYSTEMS PART 1 GENERAL 1.01 SUMMARY SECTION 21 10 00 (13900) - FIRE SUPPRESSION SYSTEMS A. Section Includes: 1. Pipe and Fittings. 2. Sprinklers. B. Related Documents: 1. Marriott s Fire Protection and Life Safety

More information

SECTION (15767) - UNIT HEATERS

SECTION (15767) - UNIT HEATERS SECTION 23 82 39 (15767) - UNIT HEATERS PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Unit Heaters. 2. Cabinet Unit Heaters. 3. Duct Heaters. 4. Baseboard Heaters. B. Related Sections: 1. Section

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

THE GUARDIAN III OWNER S MANUAL. Stops Rangetop Fires Instantly. For Installation, Operation and Maintenance

THE GUARDIAN III OWNER S MANUAL. Stops Rangetop Fires Instantly. For Installation, Operation and Maintenance THE GUARDIAN III Stops Rangetop Fires Instantly OWNER S MANUAL For Installation, Operation and Maintenance MODEL G300-A Wet Chemical Extinguisher Unit UL FILE NO. EX 3940 PATENTED 8701 John Carpenter Freeway

More information

A. Standards: Except where modified or exceeded by the requirements of this Specification, conform to the following standards:

A. Standards: Except where modified or exceeded by the requirements of this Specification, conform to the following standards: SECTION 11 53 53 BIOLOGICAL SAFETY CABINETS PART 1 - GENERAL 1.1 QUALITY ASSURANCE A. Standards: Except where modified or exceeded by the requirements of this Specification, conform to the following standards:

More information

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS (By authority conferred on the director of the department of licensing and regulatory affairs by sections

More information

Gas Station & C Store SECTION CWM Job No

Gas Station & C Store SECTION CWM Job No SECTION 21 1300 - PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in Contract

More information

University of Rochester October 17, 2008 Brooks Landing Business Center

University of Rochester October 17, 2008 Brooks Landing Business Center SECTION 087100 - DOOR HARDWARE PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Commercial door hardware. 2. Cylinders for doors specified in other Sections. 1.2 SUBMITTALS A. Product

More information

APPENDIX H (DESIGN SUBMISSION CRITERIA)

APPENDIX H (DESIGN SUBMISSION CRITERIA) APPENDIX H (DESIGN SUBMISSION CRITERIA) FIRE ALARM SYSTEM As per ACCORD standard Part 5, section 5.7 Fire Alarm System Design to be verified by ACCORD Chief Safety Inspector. Testing of the installation

More information

SECTION XPRESS II INCLINED WHEELCHAIR PLATFORM LIFT. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION XPRESS II INCLINED WHEELCHAIR PLATFORM LIFT. Display hidden notes to specifier by using Tools / Options / View / Hidden Text. SECTION 14 42 13 XPRESS II INCLINED WHEELCHAIR PLATFORM LIFT Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Indoor inclined platform

More information

SECTION DOMESTIC WATER HEATERS

SECTION DOMESTIC WATER HEATERS SECTION 223500 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

SECTION IDENTIFYING DEVICES

SECTION IDENTIFYING DEVICES PRT 1 -GENERL 1.01 RELTED DOCUMENTS SECTION 10 1425 IDENTIFYING DEVICES. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM

SECTION WET PIPE FIRE PROTECTION SPRINKLER SYSTEM SECTION 213100 WET PIPE FIRE PROTECTION SPRINKLER SYSTEM PART 1 - GENERAL 1.01 GENERAL REQUIREMENTS A. The requirements of the General Conditions and Supplementary Conditions apply to all work herein.

More information

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 635

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 635 SECTION 08331 OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 635 Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click

More information

SECTION DRY-PIPE SPRINKLER SYSTEMS

SECTION DRY-PIPE SPRINKLER SYSTEMS SECTION 21 1300 S PART 1 -GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint. (816) 373-4878 U1208-01/FAI29-029 (573) 751-2624 SECTION 2 105 17 - SLEEVES AND SLEEVE SEALS FOR FIRE-SUPPRESSION PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the

More information

SECTION ISOLATED POWER SYSTEMS

SECTION ISOLATED POWER SYSTEMS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 20 11 ISOLATED POWER SYSTEMS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE SECTION 21 1313 WET-PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Wet-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.02 RELATED

More information

SECTION AIR COILS

SECTION AIR COILS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

SECTION PLUMBING EQUIPMENT

SECTION PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Water heaters B. Packaged water heating systems C. Water storage tanks D. Water softeners E. Pumps F. Circulators 1.2 REFERENCES SECTION 22 30 00 PLUMBING EQUIPMENT

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-10 44 16 (May 2015) ------------------------ Preparing Activity: NASA Superseding UFGS-10 44 16 (May 2012) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement

More information

WALLCOVERINGS WALLCOVERINGS

WALLCOVERINGS WALLCOVERINGS 09950 - WALLCOVERINGS 09950-1 PART ONE: GENERAL 1.1 Description WALLCOVERINGS 1.1.1 Work of this Section, as shown or specified, shall be provided by the Interior Contractor and shall be in accordance

More information

A. Section Masonry Assemblies: Anchor placement in masonry.

A. Section Masonry Assemblies: Anchor placement in masonry. SECTION 14420 WHEEL CHAIR LIFT PART 1 - GENERAL 1.1 RELATED DOCUMENTS PART 1 GENERAL 1.1 SECTION INCLUDES A. Indoor inclined platform wheelchair lifts. 1.2 RELATED SECTIONS A. Section 04800 - Masonry Assemblies:

More information

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code Part 1 - GENERAL 1.1 DESCRIPTION OF WORK A. Design and installation of an engineered Kidde ECS Advanced Delivery Systems (ADS), clean agent/waterless fire suppression system employing 3M Novec 1230 waterless

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

SECTION SPRINKLER SYSTEMS

SECTION SPRINKLER SYSTEMS SECTION 15325 SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Wet-pipe sprinkler systems. B. Preaction sprinkler systems. C. System design, installation, and certification. D. Fire department

More information

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7

2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7 WET SPRINKLER Monthly Wet Sprinkler 2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7 VISUALS [per NFPA 25-1998 ed] 1. Gauge (Ck for Condition, Normal Pressure) [per 2-2.4.1] 2. Valves

More information

SECTION WATER BASED FIRE SUPPRESSION SYSTEMS

SECTION WATER BASED FIRE SUPPRESSION SYSTEMS PART 1: GENERAL 1.01 Scope of Standard A. This standard provides general guidance concerning the specific preferences of Texas State University-San Marcos for automatic fire sprinkler and standpipe systems.

More information

15900 HVAC INSTRUMENTATION AND CONTROLS

15900 HVAC INSTRUMENTATION AND CONTROLS 15900 HVAC INSTRUMENTATION AND CONTROLS PART 1 GENERAL - Andover Controls BAS system is the standard for the University, and may be specified as a proprietary item. 1.0 RELATED DOCUMENTS A. Drawings and

More information

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS SECTION 238126 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u PROPRIETARY ITEM: SMOKESHIELD S AUTOMATIC OVERHEAD PERIMETER TYPE FABRIC SMOKE CURTAIN PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Fire alarm or smoke detector-activated, overhead coiling fabric

More information

SECTION AIR OUTLETS AND INLETS

SECTION AIR OUTLETS AND INLETS SECTION 23 37 00 AIR OUTLETS AND INLETS PART 1 - GENERAL 1.1 SUMMARY A. Section includes diffusers, light troffer diffusers, registers/grilles, door grilles, louvers, louvered penthouses, roof hoods, goosenecks.

More information

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings. SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.

More information

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for

More information

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN DIVISION 21 - FIRE SUPPRESSION (REFER TO SECTION 23 05 00 FOR BASIC FIRE SUPPRESSION REQUIREMENTS) 21 05 00 Common Work Results for Fire Suppression 21 13 13 Wet-Pipe Sprinkler Systems END OF SECTION FIRE

More information

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM PART 1 - GENERAL 1.01 SUMMARY SECTION 08 34 84 ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM A. Section Includes: Fire protective elevator smoke containment curtain system designed to provide a tight-fitting,

More information

CONTENTS AUTOMATIC TRANSFER SWITCHES

CONTENTS AUTOMATIC TRANSFER SWITCHES CONTENTS AUTOMATIC TRANSFER SWITCHES PART 1 GENERAL 1.1 Related Documents 1.2 Summary 1.3 References 1.4 Quality Assurance 1.5 Submittals 1.6 Delivery, Storage and Handling 1.7 Instructions And Training

More information

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 634

SECTION OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 634 SECTION 08 33 23 OVERHEAD COILING FIRE DOORS FIREKING FIRE DOOR SERIES, MODEL 634 Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word click

More information

1. Vinyl wall covering. 2. Woven glass-fiber wall covering. 3. Textile wall covering. 4. Wallpaper. 5. Heavy-duty, synthetic, textile wall covering.

1. Vinyl wall covering. 2. Woven glass-fiber wall covering. 3. Textile wall covering. 4. Wallpaper. 5. Heavy-duty, synthetic, textile wall covering. SECTION 09950 - WALL COVERINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections,

More information

Richmond Hill Primary Renovation SECTION STAGE CURTAINS

Richmond Hill Primary Renovation SECTION STAGE CURTAINS PART 1 - GENERAL 1.01 RELATED DOCUMENTS SECTION 11 0640 STAGE CURTAINS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections,

More information

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u PROPRIETARY ITEM: FIBERHSIELD S AUTOMATIC OVERHEAD PERIMETER TYPE FABRIC FIRE CURTAIN This master specification should be read in conjunction with How to specify fire curtains technical guide to be published

More information

SECTION OVERHEAD COILING FIRE DOORS 640 SERIES OVERHEAD COILING COUNTER FIRE DOORS

SECTION OVERHEAD COILING FIRE DOORS 640 SERIES OVERHEAD COILING COUNTER FIRE DOORS SECTION 08 33 23 OVERHEAD COILING FIRE DOORS 640 SERIES OVERHEAD COILING COUNTER FIRE DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft

More information