INDUSTRIAL WARM AIR HEATERS

Size: px
Start display at page:

Download "INDUSTRIAL WARM AIR HEATERS"

Transcription

1 IDUSTRIAL WARM HEATERS IH/AR (PLUS) EXCHAGER WORKIG CHARACTERISTICS THERMIC (FURACE: Hi) kcal/h THERMIC (USEFUL) kcal/h COMBUSTIO CHAMBER COUTERPRESSURE mbar VOLUME 581,4 494, ,0 457, , IH/AR ,7 593, ,9 549, , IH/AR ,0 741, ,0 686, ,8-2, IH/AR , , ,5-4, (dm³) VETILATIO WORKIG CHARACTERISTICS IH/AR GEERAL DIRECT THROW DUCTIG S TPE OF RPM Conn. Motor / Fan t THROW HEADS OISE AT (note 2) AVAILABLE STATIC PRESSURE t OISE AT IH/AR IH/AR 500 (PLUS) 2 IH/AR IH/AR IH/AR AD 500 AD 500 AD 500 AD 560 AD 560 (rpm) (m 3 /h) (C) (m) (db) (m 3 /h) (Pa) (C) (db) 665 Ind Ind Ind Belt Belt ELECTRICAL S AD DRIVE WORKIG CHARACTERISTICS IH/AR S OF POLES ISTALLED ELECTRICAL START ELECTRICAL SUPPL PULLE PULLES PULLE PULLES (KW) (V/f/Hz) Ø (mm) Ø (mm) IH/AR ,5 COTROL 400/3/50 132/4B 1 280/2B 2 IH/AR 500 (PLUS) 1 4 9,2 IH/AR ,2 IH/AR ,5 X 2 COTROL 400/3/50 132/4B 1 250/2B 2 COTROL 400/3/50 132/4B 1 250/2B 2 COTRO L 400/3/50 150/3B 1 280/3B 2 140/3B 1 IH/AR ,5 X 3 COTRO L 400/3/50 150/3B 1 280/3B 3 140/3B 2 12

2 IDUSTRIAL WARM HEATERS IH/AR DIMESIOS (mm) A B C D E F L M G H I P Q R S Ø WEIGHT (kg) IH/AR IH/AR 500 (PLUS) IH/AR IH/AR IH/AR (*) The technical data reported is valid for mod. IH/AR 500 heaters that were manufactured after April 3, For heaters that were produced before then, the possible attached tables are valid. 11

3 IDUSTRIAL WARM HEATERS EXCHAGER WORKIG CHARACTERISTICS IH/AR THERMIC THERMIC COMBUSTIO CHAMBER (FURACE: Hi) (USEFUL) COUTERPRESSURE VOLUME kcal/h kcal/h mbar (dm³) IH/AR (PLUS) 290,7 247, ,5 228, , IH/AR (PLUS) 348,8 296, ,4 274, , IH/AR ,7 345, ,0 320, , IH/AR ,1 395, ,2 366, , VETILATIO WORKIG CHARACTERISTICS IH/AR GEERAL DIRECT THROW DUCTIG OF S. TPE OF S RPM Conn. Motor/ Fan t Max - min (nota 1) THROW HEADS OISE AT (note 2) AVAILABLE STATIC PRESSURE t Max - min (note 1) OI SE AT 1.5m (rpm) (m 3 /h) (C) (m) (db) (m 3 /h) (Pa) (C) (db) IH/AR AT 15/ Ind IH/AR 250 (PLUS) 2 AT 15/ Ind IH/AR AT 15/ Ind IH/AR 300 (PLUS) 2 AT 15/ Ind IH/AR AT 18/ Ind IH/AR AT 18/ Ind ELECTRICAL S AD DRIVE WORKIG CHARACTERISTICS IH/AR S POLES ISTALLED ELECTRICAL START ELECTRICAL SUPPL PULLE PULLES PULLE () ( V/f/Hz) Ø (mm) Ø (mm) PULLES. IH/AR ,0 IH/AR 250 (PLUS) 1 4 5,5 IH/AR ,5 IH/AR 300 (PLUS) IH/AR ,5 IH/AR ,5 SWITCH 400/3/50 125/4B 1 200/2B 2 COTROL 400/3/50 132/4B 1 200/2B 2 COTROL 400/3/50 132/4B 1 200/2B 2 COTROL 400/3/50 140/4B 1 200/2B 2 COTROL 400/3/50 112/4B 1 225/2B 2 COTROL 400/3/50 112/4B 1 200/2B 2 10

4 IDUSTRIAL WARM HEATERS IH/AR DIMESIOS (mm) A B C D E F L M G H I P Q R Ø WEIG HT (kg) IH/AR IH/AR 250 (PLUS) IH/AR IH/AR 300 (PLUS) IH/AR IH/AR ote 1: The two T values report the maximum and minimum thermic capacity. ote 2: the air capacity was measured with a load loss equal to the static pressure available for the system. 9

5 IDUSTRIAL WARM HEATERS EXCHAGER WORKIG CHARACTERISTICS IH/AR THERMIC (FURACE: Hi) THERMIC (USEFUL) COMBUSTIO CHAMBER COUTERPRESSURE VOLUME kcal/h kcal/h mbar (dm³) IH/AR 40 46,5-39, , , IH/AR 50 60,7-49, , , IH/AR 75 92,0-74, , , IH/AR ,2-98, , , IH/AR ,4-123, , , IH/AR ,8-148, , , IH/AR ,5-173, , , IH/AR ,6-197, , , OF S VETILATIO WORKIG CHARACTERISTICS IH/AR TPE OF GEERAL DIRECT THROW DUCTIG Conn. RPM Motor/ THROW Fan. t Max - min (note 1 HEADS OISE AT (note 2) AVAILABLE STATIC PRESSURE t Max - min (note 1) (rpm) (m 3 /h) (C) (m) (db) (m 3 /h) (Pa) (C) (db) IH/AR 40 1 DD 12/9 900 Dir IH/AR 50 1 DD 12/9 925 Dir IH/AR 75 1 AT 15/ Ind IH/AR AT 15/ Ind IH/AR AT 15/ Ind IH/AR AT 15/ Ind IH/AR AT 18/ Ind IH/AR AT 18/ Ind OISE AT ELECTRICAL S AD DRIVE WORKIG CHARACTERISTICS IH/AR MOT. OF POLES ISTALLED ELECTRICA L DECLARED MECHAI CAL START 8 ELECTRICAL SUPPL PULLE PULLES PULLE () () (V/f/Hz) Ø(mm) Ø (mm) IH/AR ,91 0,515 DIRECT 230/1/ IH/AR ,3 0,736 DIRECT 230/1/ IH/AR ,1 / IH/AR ,5 / IH/AR ,2 / IH/AR ,0 / IH/AR ,0 / IH/AR ,0 / SWITCH SWITCH SWITCH SWITCH SWITCH SWITCH PULLES 400/3/50 118/1B 1 225/1B 1 400/3/50 118/1B 1 200/1B 1 400/3/50 112/2B 1 200/2B 1 400/3/50 125/2B 1 200/2B 1 400/3/50 112/2B 1 225/2B 1 400/3/50 112/2B 1 200/2B 1

6 IDUSTRIAL WARM HEATERS IH/AR DIMESIOS (mm) A B C D E F G H I L M P Ø WEIG HT (Kg) IH/AR IH/AR IH/AR IH/AR IH/AR IH/AR IH/AR IH/AR

7 IDUSTRIAL WARM HEATERS EXCHAGER WORKIG CHARACTERISTICS IH/AR C -U THERMIC (FURACE: Hi) Kcal/h THERMIC (USEFUL) Kcal/h COMBUSTIO CHAMBER COUTERPRESSURE VOLUME mbar (dm³) 20 31,4-21, ,3-20, ,2 0, ,8-31, ,5-28, ,3 0, ,3-34, ,2-31, ,4 0,3 35 VETILATIO WORKIG CHARACTERISTICS IH/AR C -U GEERAL DIRECT THROW DUCTIG S TPE DD 9/9 DD 9/9 DD 9/9 RPM CO. Mot/Fan t Max - min (note 1) THROW HEADS OISE AT (note 2) t Max - min (note 1) AVAILABLE STATIC PRESSURE (rpm) (m 3 /h) (C) (m) (db) (m 3 /h) (C) (Pa) (db) 900 Direct Direct Direct OISE AT ELECTRICAL S AD DRIVE CHARACTERISTICS IH/AR C -U OF MOTO RS OF POLES ISTALLED ELECTRICAL DECLARED MECHAICAL START ELECTRICAL SUPPL PULLE PULLES PULLE PULLES () () (V/f/Hz) Ø (mm) Ø (mm) DIRECT 230/1/ DIRECT 230/1/ DIRECT 230/1/

8 IDUSTRIAL WARM HEATERS IH/AR U (UIT: GAS OIL OL ) Q C D Ø F I E H G M A B L DIMESIOS (mm) A B C D E F G H I L M Q Ø WEIG HT (kg) Tank capacity IH/AR 20 UIT IH/AR 30 UIT IH/AR 35 UIT

9 IDUSTRIAL WARM HEATERS IH/AR C (COMPACT) Q D Ø I E C F H G M A B L DIMESIOS (mm) A B C D E F G H I L M Q Ø WEIGHT (kg) IH/AR 20 COMPACT IH/AR 30 COMPACT IH/AR 35 COMPACT

10 IDUSTRIAL WARM HEATERS 1.2 TECHICAL DATA AD DIMESIOS IH/AR DIMESIOS (mm) A B C D E F G H I L M P Ø WEIGHT (Kg) IH/AR IH/AR IH/AR

11 IDUSTRIAL WARM HEATERS 1.5 WORKIG CHARACTERISTICS AD SAFET DEVICES Working characteristics Counterpressure in the combustion chamber in conformity with European standard values. Turbulation of the combustion products in the exchange pipes through stainless steel turbulators supplying a continuous and progressive action. Structure of the monoblock type heater (Mod ) including : - ventilation unit (with easy access) - thermic exchange unit (self-supporting, with easy access for periodic inspection and cleaning). Structure of the two-block type heater (Mod ) including : - ventilation unit (with easy access) - thermic exchange unit (self-supporting, with easy access for periodic inspection and cleaning). Air intake through the heater sides (for Mod also through the rear side upon request). Minimum loss of pressure relative to the air capacity when flowing through the heater; this means that there is a high available pressure for the possibile air ductings. Cover insulation made of a glass wool jacket externally covered by a galvanized sheet(sandwich type panel) in order to guarantee that the temperature difference between the external surface of the cover and the room air complies with the regulations in force. Safety and regulation thermostat devices including : - 40C fixed calibration thermostat with automatic reset. - 90C LIMIT thermostat with automatic reset C safety SICUR thermostat with manual reset. Revolving type multiple discharge heads (upon request) complete with movable fins. Filter box (upon request) made of precoated steel plate containing the extractible filtration unit and protected by a metal grill. Safety devices The device that guarantees the safety of the machine is the Safety thermostat: when it intervenes it causes the heater to shutdown completely (fan and burner) before the exiting air temperature can reach 100 C. This allows: Limiting the exiting air temperautre to values in conformity with the regulations in force. Avoiding the overheating of the exchanger and other heater parts due to system, fan or thermoregulation failures. The cause of it s intervention may be a heater malfunction: A fan malfunction A malfunction in the limit thermostat that should intervene before the safety thermostat Or a system malfunction: Increase in heat loss Decrease in the fan air capacity. Once the malfunction is removed and the heater cools down, the safety thermostat reset is done manually by pressing the reset button: Inside the electrical panel for mod Directly on the thermostat located on the outside for mod after removing the release button protection cover 18

12 IDUSTRIAL WARM HEATERS 1.4 MAUFACTURIG CHARACTERISTICS Heat exchanger entirely made of aluminized steel, resistant to high temperatures including : o Cylindrical combustion chamber with total flame return. o Flat-shape tubes with a large exchange surface. o Flue chamber with inspection for easy access cleaning. Flue turbulators made of AISI 430 stainless steel with high thermic resistance. Double suction centrifugal fans with forward inclined blades made of galvanized steel plate with dynamically balanced wheel and mounted on elastic supports. Pipe plates in aluminized steel, welded to the exchange pipes and the combustion chamber; continuous wire welding process in controlled atmosphere. Cover consisting of press-bent panels of precoated and PVC-film protected plate. Monoblock type frame supporting structure consisting of galvanized elements screwed together without welding (Mod ). Two-block type frame supporting structure; consisting of galvanized elements screwed together without welding (Mod ). Sealing gasket made of fibers in conformity with CE directives. Electrical panel built with an IP40 protection degree (IP44 for models ) containing : o main switch. o Summer-winter commutator. o Power lamp. o Working lamp. o Magneto-thermic electrical protection: Mod o Electrical protection inside motor: Mod o Fan solenoid switches: Mod o Delta-star start: Mod. 250 PLUS o Single-phase power supply 230/1/50: Mod o Triple-phase power supply 400/3/50: Mod o Upon request: triple-phase power supply 230/3/50 from model 75 to 1000 o Terminal board for connection to electrical panel 17

IH/HR IH/HR 200 IH/HR IH/HR IH/HR 600

IH/HR IH/HR 200 IH/HR IH/HR IH/HR 600 INSTRUCTIONS MANUAL FOR HIGH PERFORMANCES HIGH AIRFLOW AND HIGH AIR PRESSURE INDUSTRIAL WARM AIR HEATERS MODELS: IH/HR 100 - IH/HR 200 IH/HR 330 - IH/HR 480 - IH/HR 600 nº 6660149EN Updated 06/2008 0 CONTENTS

More information

Wall-mounted air heaters for outdoor installation MEC EX C

Wall-mounted air heaters for outdoor installation MEC EX C all-mounted air heaters for outdoor installation for ducted outdoor installation wall-mounted air heaters have been specifically designed and certified for outdoor installation. he units are equipped with

More information

PK-N Floor Standing Heater

PK-N Floor Standing Heater PK-N Floor Standing Heater The experience is mixed with technology A solution for any necessity High efficiency Heat exchanger in inox steel 55 PK-N: the heat that lasts in time Apen Group has redesigned

More information

www.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION

More information

INSTALLATION AND OPERATION MANUAL

INSTALLATION AND OPERATION MANUAL INSTALLATION AND OPERATION MANUAL PRESSURISED STEEL BOILERS AR 30 AR 1000 RADIALAND - BOILER's INSTALLATION MANUAL version 1.0 / 15-02-2008 The company E. is outstanding in the field of central heating

More information

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23 Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B Type B 23 on the wall Ø 80 duct, available in the following lengths: 1000,

More information

Roof top SPACE RPC 315Z R407C MA00

Roof top SPACE RPC 315Z R407C MA00 Client : TIHE SERV Contact : Romeo Staicu Your reference : Your contact : Phone : E-mail : Page : 1 / 6 Roof top SPACE RPC 315Z R407C MA00 Independant roof mounted unit, cooling only, ready to be installed,

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY FRAL SRL via dell industria e dell artigianato, 22/C - 35010 Carmignano di Brenta - PADOVA - ITALY TELPHONE: +39 049 9455839 FAX: +39 049 5991129 E-MAIL: info@fral.it WEB: www.fral.it DEHUMIDIFIERS FD

More information

E U R O V E N T CERTIFIED PERFORMANCE

E U R O V E N T CERTIFIED PERFORMANCE Compact Horizontal Air-Air Heat Pump Model RTH-7K to 3K Ref.: Y-R719 7 Technical information E U R O V E N T CERTIFIED PERFORMANCE I S O 9 1 ER-8/1991 Clima Roca York S.L. is participating in the EUROVENT

More information

Light oil - kerosene burner

Light oil - kerosene burner Installation, use and maintenance instructions Light oil - kerosene burner One stage operation CODE MODEL TYPE 374374 G3B 437T 90 (4) - 05/0 TECHNICAL FEATURES TYPE 437T Thermal power output 9 35 kw.6

More information

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods

More information

ZOOM STEAM PIPES DECKS OVEN

ZOOM STEAM PIPES DECKS OVEN ZOOM STEAM PIPES DECKS OVEN 01 ZOOM ZOOM IS A STEAM PIPE OVEN WITH FOUR OVERLAPPING BAKING CHAMBERS. IT IS DESIGNED TO SATISFY THE BEST RATIO BETWEEN CAPACITY, POWER AND COSTS. THE CHIEF CHARACTERISTIC

More information

ENERGY TOP. Condensing boiler solutions

ENERGY TOP. Condensing boiler solutions ENERGY TOP Condensing boiler solutions 1 ENERGY TOP > ENERGY TOP RANGE A wide array of flexible solutions both for centralised residential application and big commercial plants The increasing need for

More information

CP+ Gas & Oil Cabinet Heater Range

CP+ Gas & Oil Cabinet Heater Range CP+ Gas & Oil Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk CP+ CP+EA External Heater HEATING // VENTILATION // AIR CONDITIONING // OEM PRODUCTS CP+ Overview Designed

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

W - WR - WD. Technical information W- WR - WD. Gas-fired convection heaters with fan

W - WR - WD. Technical information W- WR - WD. Gas-fired convection heaters with fan Gas-fired convection heaters with fan W - WR - WD Technical information A2B srl - Via d Ancona, 37-60027 Osimo (An) Tel. 071.723991 - Fax 071.7133153 - Web Site: www.accorroni.it - E-mail: a2b@a-2-b.it

More information

Oil burners Brûleurs fioul Stookoliebranders

Oil burners Brûleurs fioul Stookoliebranders Installation, use and maintenance instructions Manuel d entretien Installatie-, gebruiks- en onderhoudsvoorschriften GB F NL Oil burners Brûleurs fioul Stookoliebranders One stage operation Fonctionnement

More information

Gas-fired unit heaters for indoor installation

Gas-fired unit heaters for indoor installation UDSA & UDSBD model Gas-fired unit heaters for indoor installation Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new heat

More information

TECHNICAL SPECIFICATIONS ASSEMBLY, USE AND MAINTENANCE INSTRUCTIONS VERTICAL WARM AIR HEATERS WITH CABINET RANGE BA-S

TECHNICAL SPECIFICATIONS ASSEMBLY, USE AND MAINTENANCE INSTRUCTIONS VERTICAL WARM AIR HEATERS WITH CABINET RANGE BA-S TECHNICAL SPECIFICATIONS ASSEMBLY, USE AND MAINTENANCE INSTRUCTIONS VERTICAL WARM AIR HEATERS WITH CABINET RANGE BA-S 1 Dear Customer, Thank you for choosing a our WARM AIR HEATER, BA-S series an innovative

More information

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R Packaged air conditioning unit condensed by air model RTC 07L to 30L Ref.: Y-R70167 0707 Technical information I S O 9 0 0 1 ER-0028/1991 Johnson Controls Manufacturing España, S.L. is participating in

More information

CONDOR RAPID CONDOR RAPID/V STEAM FORCED CIRCULATION. Design pressure 11,76 bar Steam production from 45 to Kg/h

CONDOR RAPID CONDOR RAPID/V STEAM FORCED CIRCULATION. Design pressure 11,76 bar Steam production from 45 to Kg/h FORCED CIRCULATION Design pressure 11,76 bar Steam production from 45 to 4.000 Kg/h /V Design pressure 11,76 bar Steam production from 45 to 2.000 Kg/h INDUSTRIAL BOILER ITALY S.R.L. Offices and Production

More information

Light oil burners. One stage operation

Light oil burners. One stage operation Installation, use and maintenance instructions Light oil burners One stage operation CODE MODEL TYPE 3505 RDB CF 38 50 T3 350050 RDBR CF 6 50 TR 35050 RDBR CF 33 50 TR 35050 RDBR CF 38 50 T3R 350650 RDBR

More information

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59 SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery

More information

E U R O V E N T CERTIFIED PERFORMANCE

E U R O V E N T CERTIFIED PERFORMANCE Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L Ref.: Y-R70171 0707 Technical information E U R O V E N T CERTIFIED PERFORMANCE I S O 9 0 0 1 ER-0028/1991 Johnson Controls Manufacturing España,

More information

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control PRODUCT selection data Wide range of chilled water cabinets Compact and attractive design EC motor for energy savings Auto-adaptive control Easy to install Close Control Unit 50CO Translation of the original

More information

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model Calder Plus High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing Outputs 70-3500 kw Calder Plus Model 70-1300 Calder Plus Model 1400-3500 Calder Plus - High Efficiency

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Parts Available from

Parts Available from Montage und Bedienungsanleitung Manuel d entretien Installation, use and maintenance instructions Installatie-, gebruiks- en onderhoudsvoorschriften Oδηγίες εγκατάστασης, χρήσης και συντήρησης D F GB NL

More information

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42 SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING

More information

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: N Packaged air conditioning unit condensed by air model RTC 07L to 30L Ref.: N-27656 0608 Technical information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

RIELLO 40 GS/M SERIES

RIELLO 40 GS/M SERIES The Riello 40 GS/M series of two stage progressive or modulating gas burners, is a complete range of products developed to respond to any request of gas burners for hot air generator according to EN 1020.

More information

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10 Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index

More information

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L Ref.: N-27661 0608 Technical information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification Program. Products

More information

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT 1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»

More information

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC DB Suspended heat recovery air handling units 2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.

More information

Industrial Chiller s construction Chiller s description: Class WecoSpar EcoSpar - Spar

Industrial Chiller s construction Chiller s description: Class WecoSpar EcoSpar - Spar 2017/2018 Industrial Chiller s construction Chiller s description: Class WecoSpar EcoSpar - Spar Chiller with or without inverter in the compressors 1 The construction A chiller forever concept Economizer,

More information

ROOFTOP PACKAGED AIR CONDITIONERS

ROOFTOP PACKAGED AIR CONDITIONERS ROOFTOP PACKAGED AIR CONDITIONERS Rooftop Packaged Air Conditioners Hitachi has long been a world leader in the design and manufacture of quality air conditioning systems. With models ranging from room

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment! OnePlus Packaged Air Handling Units for Ducted Installations Caring for the environment! A New Concept New packaged air handling units OnePlus series are the latest offspring of Apen Group s experience.

More information

... UDSA - UDSBD Gas fired unit heaters...

... UDSA - UDSBD Gas fired unit heaters... UDSA - UDSBD Gas fired unit heaters UDSA with axial fan Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new horizontal heat

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

GAS AIR HEATER RANGE

GAS AIR HEATER RANGE GAS AIR HEATER RANGE ATH Horizontal gas air heater ATC Centrifugal gas air heater ATV Vertical gas air heater Address : Yahtec - 6 rue Pascal 7700 Meaux - France Phone number :+ (0) 60 4 4 86 Multiple

More information

RODI DUAL RODI DUAL HR

RODI DUAL RODI DUAL HR IST 03 C 320-04 RODI DUAL RODI DUAL HR PRESSURISED STEEL BOILER EN INSTALLATION USE AND MAINTENANCE Dear Customer, Thank you selecting our company and choosing to purchase our products. We invite you to

More information

GAS-FIRED AIR HEATERS MEC - MEC C SERIES Models Technical information

GAS-FIRED AIR HEATERS MEC - MEC C SERIES Models Technical information This manual is divided into three sections: GAS-FIRED AIR HEATERS MEC - MEC C SERIES Models 25-30 - 35-50 - 57-85 - SECTION 1 - GENERAL INFORMATION Technical information It contains all the information

More information

Roof top SPACE RPC 450Z R407C M011

Roof top SPACE RPC 450Z R407C M011 Roof top SPACE RPC 450Z R407C M011 Page : 1 / 5 Independant roof mounted unit, cooling only, ready to be installed, designed for air conditioning of large volumes for industrial or commercial use. As per

More information

Light oil / kerosene burner

Light oil / kerosene burner Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h

More information

GAS SERIES HOT AIR GENERATORS (FLOOR) HANDBOOK MODELS : GAS 20 GAS 25 GAS 29 GAS 40

GAS SERIES HOT AIR GENERATORS (FLOOR) HANDBOOK MODELS : GAS 20 GAS 25 GAS 29 GAS 40 HEAD OFFICE : VIA BIBAN 56 ( Z.I. ) 31030 CARBONERA TREVISO - ITALIA TEL. ++39 0422 445363 FAX ++39 0422 398646 EMAIL = info@bpstecnologie.com 1312 GAS SERIES HOT AIR GENERATORS (FLOOR) HANDBOOK MODELS

More information

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER AIR HEATING TECHNOLOGY AND INNOVATION AXIAL FANS AND CENTRIFUGAL FANS HEATING COOLING GREEN ENERGY EOLO VIP: NEW! VERY IMPORTANT PERFORMANCE The

More information

HEATING HEATING EQUIPMENT FOR AGRICULTURAL AND INDUSTRIAL APPLICATIONS. since

HEATING HEATING EQUIPMENT FOR AGRICULTURAL AND INDUSTRIAL APPLICATIONS. since HETING HETING EQUIPMENT FOR GRICULTURL ND INDUSTRIL PPLICTIONS since 1967 DIRECT GS-FIRED IR HETER The air heater agriterm was developed for livestock buildings. It is entirely made of stainless steel

More information

Gas heaters and convectors ROBUR

Gas heaters and convectors ROBUR Gas heaters and convectors ROBUR Table of Contents Robur M general characteristic...3 Robur M dimensions...3 Robur M construction...4 Robur M technical data...5 Robur M installation...6 Robur M accessories...7

More information

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted All Heaters Part L2B Compliant Technical Data External Oil and Gas Cabinet Heaters For Models EVD Vertical Ducted EHD Hortizontal Ducted Range & Configuration Vertical Forced Draught Oil and Gas 29 kw

More information

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range PRODUCT SELECTION DATA Plug & play unit (built-in control) Class A+ across entire range Classic/Vertical/ceiling-mounted dualflow units High-efficiency heat recovery unit High performance plug fan High-efficiency

More information

VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range VPC Gas Cabinet Heater Range Industrial & Commercial Heating Systems. www.powrmatic.co.uk HEATING // VENTIATION // AIR CONDITIONING // OEM PRODUCTS VPC Overview Models Available VPC UF - Upright Freeblowing

More information

SECTION ROOFTOP REPLACEMENT AIR UNITS

SECTION ROOFTOP REPLACEMENT AIR UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Specification Sections, apply to this Section. B. Related

More information

RFA TECHNICAL MANUAL SINGLE PACKAGED ROOFTOP UNITS ROOF-TOP. Mod

RFA TECHNICAL MANUAL SINGLE PACKAGED ROOFTOP UNITS ROOF-TOP. Mod RFA SINGLE PACKAGED ROOFTOP UNITS ROOF-TOP 34.4 9.8 kw in cooling mode 38.6 117.8 kw in heating mode DOZONE SAVE Mod. 35.1 45.1 55.1 70.2 90.2 1.2 TECHNICAL MANUAL TABLE OF CONTENTS GENERAL FEATURES................................................................................

More information

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions Dehumidifiers for radiant cooling systems FH GH 138 The dehumidifiers FH and GH series are high performance units, equipped with robust galvanised steel frame, properly designed to operate in combination

More information

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof

More information

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A smoke pipes VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 OUTPUT RANGE from 115 to 600 kw OPERATION TEMPERATURE no limit on the return temperature SUPPLY Natural Gas or LPG MODELS 150 230 300 348

More information

Installation and operating instructions B1FUV Classic

Installation and operating instructions B1FUV Classic Installation and operating instructions B1FUV Classic 1 171 135 10 05-02 178 033 31 Contents 01. GENERAL... 5 Description... 5 Declaration of conformity... 6 Safety directions... 7 02. TECHNICAL DATA...

More information

MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION

MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION Do Žlábku 733, 514 01 Jilemnice Subject: MTP (MTPAL) Technical Documentation Page 1 of 13 MTP (MTPAL) AIR HEATERS TECHNICAL DOCUMENTATION Table of Contents: Page: 2 Warranty Certificate 3 Quality and Completeness

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

Prextherm Rsw High efficiency steel pressurised boilers

Prextherm Rsw High efficiency steel pressurised boilers Prextherm Rsw High efficiency steel pressurised boilers > PREXTHERM RSW TOP RELIABILITY AND PERFORMANCES Prextherm RSW range consists in pressurised boilers with reversal flame technology. The historical

More information

GAS FIRED AIR HEATERS

GAS FIRED AIR HEATERS Installation and maintenance manual GAS FIRED AIR HEATERS FHAR..H/V/C DTC ARM 17-299 EN 1312BO3933 1 TABLE OF CONTENTS Section N Sections Pages 1 GENERAL INFORMATIONS 4 à 5 1.1 General recommendations

More information

The technical and dimensional data reported in this manual may be modified in view of any product improvement.

The technical and dimensional data reported in this manual may be modified in view of any product improvement. fan coils technical manual GB E U R O V E T CERTIFIED PERFORMACE IDEX MAI FEATURES... VERSIOS AD MAI COMPOETS... 3-3 AVAILABLE ACCESSORIES... 5 RATED TECHICAL FEATURES... 6-7. Fan coils with heat exchanger

More information

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range is an efficient and low-noise product designed for medium to big applications. The water chillers are suitable for water outlet temperatures

More information

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems Technical Bulletin BT13F002GB-04 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR

More information

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw The RL/1 burners series covers a firing range from 107 to 398 kw, and it has been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil boilers. Optimisation

More information

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit MODEL: ACW200D ACW300D ACW400D ACW500D ACW600D ACW800D ACW900D ACW1000D ACW1200D ACW1400D ACWD-2006 ACWD_2006_Cover.indd 1 CEILING CONCEALED Chilled Water Fan Coils Unit 2006-5-25 17:24:07 Contents Main

More information

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat C 146-02 made in Italy Elba Dual Cast-iron, floor-standing boiler High quality Italian product Life-enhancing heat GB Cast-iron, floor-standing boiler Elba Dual RELIABILITY SAFETY QUALITY EASY TO OPERATE

More information

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model Calder Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing Outputs 70-3500 kw Calder Model 70-1300 Calder Model 1400-3500 Calder - Steel Hot Water Boiler The Calder

More information

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat

C Bali R. Cast-iron boilers with atmospheric gas-fired burner. Life-enhancing heat C 083-03 Bali R Cast-iron boilers with atmospheric gas-fired burner Life-enhancing heat GB Cast-iron boilers with atmospheric gas-fired burner Bali R Easy installation Silent operation Long life Wide range

More information

K X V and K X O WALL SERIES HOT AIR GENERATORS USE & MAINTENANCE HANDBOOK

K X V and K X O WALL SERIES HOT AIR GENERATORS USE & MAINTENANCE HANDBOOK HEAD OFFICE : VIA BIBAN 56 ( Z.I. ) 31030 CARBONERA TREVISO - ITALIA TEL. ++39 0422 445363 FAX ++39 0422 398646 EMAIL = info@bpstecnologie.com K X V and K X O WALL SERIES HOT AIR GENERATORS USE & MAINTENANCE

More information

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO .Technical specifications Boiler power DESCRIPTION Water content in a boiler Required draft Supply

More information

white blue cobalt bordeaux light oak (rovere)

white blue cobalt bordeaux light oak (rovere) KON1 is the newest addition in the line of décor boilers produced by Unical in synergy with ArtÙ Design Studio. Soft lines, with an elegant front panel available in different colours, enclosing a state-of-the-art

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T is characterized by having no additional moisture added

More information

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SERIES: WCHZ MODELS: 201, 251, 271, 351, 401, 501, 701, 721, 751 COOLING CAPACITIES OF: 6,4

More information

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS INSTRUCTION MANUAL FOR OIL BURNER MODELS X400 Bio B10 E90-803-001-001-03 Rev 13-1 - Contents Technical specifications Technical data... 3 Working field... 3 Dimensions... 4 Head and electrode settings...

More information

LOW STATIC HYDRONIC DUCTED UNIT

LOW STATIC HYDRONIC DUCTED UNIT LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity

More information

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS MCF 00 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS MCF 00 CENTRIFUGAL FAN FOR COMBUSTIBLE GASES MCF 00 centrifugal fan for biogas, natural gas or combustible gases, in conformity to the

More information

OPUS PLUS TWINFANS COMPACT & POWERFUL, IDEAL FOR LARGER ROOM APPLICATIONS WHILST MAINTAINING LOW NOISE LEVELS.

OPUS PLUS TWINFANS COMPACT & POWERFUL, IDEAL FOR LARGER ROOM APPLICATIONS WHILST MAINTAINING LOW NOISE LEVELS. TWIFAS COMPACT & POWERFU, IDEA FOR ARGER ROOM APPICATIOS WHIST MAITAIIG OW OISE EVES. 9 85 8 5 Speed Control TWI FAS BEEFITS COMPACT & POWERFU Small design, high performance up to 5I/s - ideal for larger

More information

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning VPC Gas Cabinet Heater Range Architects of your environment heating ventilation air conditioning 1 Product Overview Benefits Installer Friendly ow evel Flue Discharge Option (No Roof Work) Room Sealed

More information

en Direct oil-fired space heaters HD... Operator's manual

en Direct oil-fired space heaters HD... Operator's manual 0211670en 002 12.2007 Direct oil-fired space heaters HD... Operator's manual Table of contents 1. Foreword 5 2. Safety information 6 2.1 General recommendations... 6 2.2 Safety devices... 7 2.3 Labels...

More information

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THIS BOOKLET FOR REFERENCE Please use this product according to the installation and operating instructions.

More information

manual addendum DELPHI Ex

manual addendum DELPHI Ex manual addendum DELPHI Ex II 2G Ex eb IIC T4 Gb II 2D Ex tb IIIC T135 C IP65 Db Tamb=-20 +40 C Reference list: Norm (last issue) Title Dir. 2014/34/UE EN 60079-31 EN60079-0 EN60079-7 Equipment and Protective

More information

Easyfire Standalone biomass pellet boiler

Easyfire Standalone biomass pellet boiler Easyfire Standalone biomass pellet boiler DESIGN Essential and pleasant AESTETIC, small size If the humanity is in balance with the resources of nature, the respect for the environment will be possible.

More information

BIX B-One 100 kw INSTALLATION GUIDE

BIX B-One 100 kw INSTALLATION GUIDE BIX B-One 100 kw INSTALLATION GUIDE Dear Customer, We thank you for choosing our product. The Bix B-One 100 Kw is a burner of advanced concept and technology, with a high reliability and construction quality.

More information

Rapid. Suspended Warm Air Heater. Caring for the environment!

Rapid. Suspended Warm Air Heater. Caring for the environment! Rapid Suspended Warm Air Heater Caring for the environment! RAPID The QUICK and ECOLOGICAL Suspended Heater Our RAPID heaters were conceived and designed for the heating of industrial and commercial buildings.

More information

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system

More information

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...

More information

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired Form No. 8700 Bryan Flexible Water Tube TM Triple-Flex Series Ultra-High Efficiency Condensing Hot Water Boilers 3,000,000 BTUH Natural Gas Fired Minimum 90% Thermal Efficiency at 160 F Return with 20

More information

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK GENERAL Climate Wizard coolers operate with a high ratio of energy efficiency and deliver cool fresh air at extremely low energy cost. The CW-80T-TWIN is characterized by having no additional moisture

More information

Centrifugal air heaters hot water or electrical supply

Centrifugal air heaters hot water or electrical supply The economical solution with centralised production Individual adjustment in each room The most silent electric air heater to protect against frost or to heat large spaces A wide range of accessories Range:

More information

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

BENSON LINEAR RADIANT TUBE

BENSON LINEAR RADIANT TUBE BENSON LINEAR RADIANT TUBE Natural or Propane (Gas fired) I N S T A L L A T I O N C O M M I S S I O N I N G S E R V I C I N G U S E R I N S T R U C T I O N S September 2001 CONTENTS Page Compliance Notices

More information