DUCTWORK FITTINGS DAMPERS AND CONTROLS AD ACCESS DOOR

Size: px
Start display at page:

Download "DUCTWORK FITTINGS DAMPERS AND CONTROLS AD ACCESS DOOR"

Transcription

1

2

3

4

5 MECHANICAL SYMBOLS AN ABBREVIATIONS NOTE: NOT ALL SYMBOLS AN ABBREVIATIONS INICATE HERE ARE USE IN THE RAWINGS AN MAY NOT APPLY TO THIS PROJECT. AITIONAL SYMBOLS MAY BE INICATE IN THE RAWINGS. MECHANICAL ABBREVIATIONS PIPING SYSTEMS AN FITTINGS UCTWORK FITTINGS AMPERS AN CONTROLS A ACCESS OOR MAX MAXIMUM AJ AJUSTABLE MBH THOUSANS OF BTU PER HOUR AFF ABOVE FINISHE FLOOR MC MECHANICAL CONTRACTOR AL ALUMINUM MCA MINIMUM CIRCUIT AMPACITY ALT ALTERNATE MCC MOTOR CONTROL CENTER AP ACCESS PANEL MEP MECHANICAL, ELECTRICAL AN PLUMBING AP AIR PRESSURE ROP MER MECHANICAL EQUIPMENT ROOM APPROX APPROXIMATE MEZZ MEZZANINE ARCH ARCHITECTURAL MFR MANUFACTURER AVG AVERAGE MIN. MINIMUM MISC MISCELLANEOUS BAS BUILING AUTOMATION SYSTEM BOB BOTTOM OF BEAM NA NOT APPLICABLE BO BOTTOM OF UCT NC NORMALLY CLOSE BOP BOTTOM OF PIPE NIC NOT IN CONTRACT BTU BRITISH THERMAL UNITS NO NORMALLY OPEN BTUH BRITISH THERMAL UNITS PER HOUR NPS NPSH NOMINAL PIPE SIZE NET POSITIVE SUCTION HEA NPT NATIONAL PIPE THREA CAV CONSTANT AIR VOLUME NR NEAR CFH CUBIC FEET PER HOUR NTS NOT TO SCALE CFM CUBIC FEET PER MINUTE CL CENTERLINE OA OUTSIE AIR CLG CEILING OC ON CENTER CON CONENSATE OE OPEN EN UCT CONTR CONTRACTOR OLP OVERLOA PROTECTION COP COEFFICIENT OF PERFORMANCE OV OUTLET VELOCITY CU COPPER PC PLUMBING CONTRACTOR AP UCT ACCESS PANEL PCF POUNS PER CUBIC FOOT B RY BULB P PRESSURE ROP C IRECT IGITAL CONTROL PH PHASE EG EGREES PLBG PLUMBING IA IAMETER POC POINT OF CONNECTION IM IMENSION PPH POUNS PER HOUR N OWN PRV PRESSURE RELIEF VALVE WG RAWING PSF POUNS PER SQUARE FOOT X IRECT EXPANSION PSI POUNS PER SQUARE INCH PSIA EA EXHAUST AIR PSIG POUNS PER SQUARE INCH GAUGE EAT ENTERING AIR TEMPERATURE PVC POLYVINYL CHLORIE EC ELECTRICAL CONTRACTOR ER EQUIVALENT IRECT RAIATION RA RETURN AIR EFF EFFICIENCY REQ REQUIRE ELEC ELECTRICAL RF ROOF ELEV ELEVATION RH RELATIVE HUMIITY EM EMERGENCY RPM REVOLUTIONS PER MINUTE ESP EXTERNAL STATIC PRESSURE ETR TO REMAIN SA SUPPLY AIR EWT ENTERING WATER TEMPERATURE SCH SCHEULE EXH EXHAUST SHT SHEET EXP EXPANSION SP STATIC PRESSURE EXIST SPEC SPECIFICATION SQ SQUARE F FAHRENHEIT S/S STAINLESS STEEL FC FORWAR CURVE ST STANAR FLA FULL LOA AMPS STRUCT STRUCTURAL FLR FLOOR FM FACTORY MUTUAL T&P TEMPERATURE AN PRESSURE FP FLUI PRESSURE ROP TA TRANSFER AIR FPI FINS PER INCH TBR TO BE REMOVE FPM FEET PER MINUTE TC TEMPERATURE CONTROL FPS FEET PER SECON TEMP TEMPERATURE F&T FLOAT AN THERMOSTATIC TOB TOP OF BEAM FT FEET TO TOP OF UCT FTG FOOTING TOP TOP OF PIPE TOS TOP OF SLAB GA GAUGE TSP TOTAL STATIC PRESSURE GAL GALLON T STAT THERMOSTAT GALV GALVANIZE TYP TYPICAL GB GRAVITY BACKRAFT AMPER UC UNERCUT OOR " (BY GENERAL GC GENERAL CONTRACTOR CONTRACTOR) GPM GALLONS PER MINUTE UNO UNLESS OTHERWISE NOTE GPH GALLONS PER HOUR V VOLTS HP HORSEPOWER VA VALVE VAV VARIABLE AIR VOLUME I INSIE IAMETER VEL VELOCITY IE INVERT ELEVATION VP VELOCITY PRESSURE IN INCHES VTR VENT THRU ROOF LAT LEAVING AIR TEMPERATURE LB/HR POUNS PER HOUR LF LINEAR FEET LTG LIGHTING LWT LEAVING WATER TEMPERATURE MECHANICAL EQUIPMENT ABBREVIATIONS AC AIR CONITIONING UNIT/AIR COMPRESSOR ACC AIR COOLE CONENSER ACCU AIR COOLE CONENSING UNIT ACU AIR CONITIONING UNIT AHU AIR HANLING UNIT AM AIR MIXING EVICE ARU AIR ROTATION UNIT AS AIR SEPARATOR AT AIR TERMINAL EVICE B BOILER BBS BOILER BLOWOWN SEPARATOR BC BOOSTER COIL BFS BOILER FEEWATER SYSTEM W/ WITH W/O WITHOUT WB WET BULB WC WATER COLUMN WG WATER GAUGE X GF GV GAS FURNACE GRAVITY VENTILATOR H HUMIIFIER HC HEATING COIL HP HEAT PUMP HRC HEAT RECOVERY COIL HR HEAT RECLAIM EVICE HX HEAT EXCHANGER IAH INTAKE AIR HOO IF INLINE FAN IFH INFRARE HEATER LP LOUVERE PENTHOUSE BOILER BLOW OWN BOILER FEE BREATHABLE AIR CHILLE WATER SUPPLY CHILLE WATER RETURN COMPRESSE AIR CONENSER WATER SUPPLY CONENSER WATER RETURN RAIN LINE FUEL OIL FILL FUEL OIL SUPPLY FUEL OIL RETURN FUEL OIL VENT GLYCOL CHILLE WATER SUPPLY GLYCOL CHILLE WATER RETURN HEAT PUMP WATER SUPPLY HEAT PUMP WATER RETURN HIGH PRESSURE STEAM HIGH PRESSURE CONENSATE HOT WATER SUPPLY HOT WATER RETURN HUMIIFICATION LIQUEFIE PETROLEUM GAS MAKE-UP WATER MEIUM PRESSURE STEAM MEIUM PRESSURE CONENSATE NATURAL GAS NITROGEN VENT LINE PUMPE CONENSATE REFRIGERANT HOT GAS REFRIGERANT LIQUI REFRIGERANT SUCTION REFRIGERANT VENT VACUUM (AIR) PIPE VALVES AN SPECIALTIES C.S. LOW PRESSURE STEAM (0 PSIG) LOW PRESSURE CONENSATE ANGLE VALVE BALANCING VALVE (CIRCUIT SETTER) BALL VALVE BUTTERFLY VALVE BUTTERFLY VALVE WITH ACTUATOR CHECK VALVE (ARROW INICATES FLOW IRECTION) IAPHRAGM VALVE RAIN VALVE WITH CAPPE OUTLET FLOAT OPERATE VALVE GATE VALVE GLOBE VALVE PLUG VALVE PRESSURE REUCING VALVE PRESSURE RELIEF VALVE SHUTOFF VALVE (SEE SPECIFICATION FOR TYPE) SOLENOI VALVE THERMAL EXPANSION VALVE TRIPLE UTY VALVE 2-WAY CONTROL VALVE FLANGE UNION ANCHOR PIPE GUIE ECCENTRIC REUCER CONCENTRIC REUCER LINE CONTINUATION BREAK PIPELINE STRAINER ELBOW OWN ELBOW UP TEE OWN TEE UP PIPE CAP VALVE IN VERTICAL NOTE: (X) PRIOR TO SYSTEM TYPE ENOTES PIPING (i.e. XHWS - HOT WATER SUPPLY) (XX) = SYSTEM PRESSURE IN PSIG (i.e. (5 PSIG)G) R AUTOMATIC AIR VENT MANUAL AIR VENT BALL JOINT EXPANSION JOINT FLEXIBLE CONNECTION FLOW SWITCH FLOW METER PETE'S PLUG PRESSURE GAUGE PRESSURE SWITCH STEAM TRAP (INICATE TYPE: T - THERMOSTATIC TRAP F&T - FLOAT AN THERMOSTATIC TRAP IB - INVERTE BUCKET TRAP) THERMOMETER IRECTION OF FLOW IRECTION OF PITCH RISE (R) OR ROP () SINGLE LINE UCTWORK 45 THIS UCT RUNS UNERNEATH RECTANGULAR/ROUN BRANCH TAKE OFF (SA, RA, AN EA) /4 BUT NOT NOT LESS 6" IFFUSER, GRILLE, AN REGISTER NOTATION UCT SIZE IN INCHES (NET INSIE IMENSIONS) FIRST FIGURE: SIE SHOWN SECON FIGURE: SIE NOT SHOWN 2X2 OUBLE LINE UCTWORK W W R=.5W RAIUS ELBOW /4 W BUT NOT NOT LESS 6" TEE (FOR LOW PRESSURE SUPPLY AIR UCTWORK ONLY) 5 MAX. FOR IVERGING TRANSITION, 25 MAX. FOR CONVERGING TRANSITION - ECCENTRIC 5 MAX. FOR IVERGING TRANSITION, 25 MAX. FOR CONVERGING TRANSITION - CONCENTRIC UCT WITH FLOW IRECTION ARROW LINE CONTINUATION BREAK (RECTANGULAR, ROUN) SUPPLY AIR (SA) OR OUTOOR AIR (OA) UCT UP SUPPLY AIR (SA) OR OUTOOR AIR (OA) UCT OWN RETURN AIR (RA), RELIEF AIR OR TRANSFER AIR (TA) UCT UP RETURN AIR (RA), RELIEF AIR OR TRANSFER AIR (TA) UCT OWN EXHAUST AIR (EA) UCT UP EXHAUST AIR (EA) UCT OWN UCT RISE/ROP W/ 90 ELBOWS (SUPPLY RECTANGULAR UCT SHOWN) SQUARE ELBOW WITH TURNING VANES EITHER RAIUS OR SQUARE ELBOW (REFER TO SPECIFICATION FOR AITIONAL REQUIREMENTS) UCT RISE (R) OR ROP () W/ 30 ELBOWS (RECTANGULAR UCTS) UCT CROSS OVER A 000 0"Ø (TYP.2) 2"Ø INICATES ROUN UCTWORK 2X2 INICATES OVAL ROUN UCTWORK IFFUSER/GRILLE MARK CFM NECK SIZE TYPICAL OF QUANTITY B M MANUAL VOLUME AMPER FIRE AMPER SMOKE AMPER COMBINATION FIRE/ SMOKE AMPER BACKRAFT AMPER MOTORIZE AMPER UCTWORK SPECIALTIES NEW A UCT REHEAT COIL TEST HOLE ACCESS OOR GENERAL NOTES NEW TO UCT CONNECTION REMOVE UCTWORK SPACE THERMOSTAT SPACE HUMIISTAT NIGHT CYCLE CONTROL THERMOSTAT TEMPERATURE SENSOR HUMIITY SENSOR PRESSURE SENSOR UCT SMOKE ETECTOR STARTER SPEE SWITCH 3 2 FLEXIBLE UCT POINT OF CHANGE IN UCT CONSTRUCTION BY PRESSURE CLASS LINE UCTWORK. ALL WORK SHALL BE PERFORME IN A NEAT AN WORKMANLIKE MANNER AN AN SHALL COMPLY WITH ALL AOPTE LOCAL, STATE, AN NATIONAL COES. 2. O NOT SCALE THE RAWINGS. 3. RAWINGS ARE IAGRAMMATIC. CONTRACTOR TO INSTALL PIPE AN UCTWORK IN A MANNER ACCORING TO GOO PRACTICE. ANY MAJOR EVIATIONS REQUIRE FROM THE ESIGN RAWINGS SHALL BE VERIFIE WITH THE ENGINEER/ARCHITECT. 4. FINAL ELECTRICAL CONNECTIONS AT OR ABOVE 20V SHALL BE MAE BY THE ELECTRICAL CONTRACTOR. 5. INSTALL BALANCING AMPERS AN SPLITTER AMPERS AS SHOWN AN AS REQUIRE FOR PROPER BALANCING OF THE MECHANICAL SYSTEM. PROVIE TO THE ENGINEER/OWNER A BALANCING REPORT SHOWING RESULTS OF BALANCE TESTING. ALL BALANCE TESTING SHALL MEET THE CURRENT NEBB STANARS. 6. O NOT LOCATE FCU'S, VAV'S, OR FPT'S ABOVE LIGHTS OR CONFERENCE ROOMS. 7. REFER TO STRUCTURAL RAWINGS AN OTHER ISCIPLINES FOR COORINATING UCT ROUTING IN CEILING PLENUM SPACE. 8. PROVIE A SET OF RECOR RAWINGS OF THE ACTUAL INSTALLATION. RECOR RAWINGS SHALL INCLUE AS A MINIMUM, THE LOCATION AN PERFORMANCE ATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF UCT & PIPE ISTRIBUTION SYSTEM INCLUING SIZES AN THE TERMINAL AIR ESIGN FLOW RATES. 9. AVOI ROUTING OF PIPING OR UCTWORK ABOVE IT, ELECTRICAL OR FIRE EQUIPMENT ROOMS. 0. PROVIE APPROPRIATELY RATE FIRE STOPPING FOR PENETRATIONS THROUGH FIRE-RATE WALLS. REFER TO ARCHITECTURAL RAWINGS FOR LOCATIONS OF FIRE RATE STRUCTURES.. COORINATE THERMOSTAT, SENSOR AN SWITCH LOCATIONS WITH ARCHITECT/OWNER PRIOR TO INSTALLATION. 2. PROVIE UCT TRANSITIONS FROM EQUIPMENT CONNECTIONS TO UCT SIZES SHOWN. 3. FLEXIBLE UCT SHALL BE INSULATE AN SHALL BE THE SAME SIZE OF THE NECK OF THE AIR EVICE. FLEXIBLE UCTWORK SHALL NOT EXCEE 8'-0" IN LENGTH, PROVIE WRAPPE RIGI ROUN UCTWORK FOR TAKE-OFFS IN EXCESS OF 8'-0". 4. MAINTAIN A MINIMUM 0'-0" SEPARATION FROM OUTSIE AIR INTAKES TO EXHAUST TERMINATIONS AN VENTS. 5. MAINTAIN A MINIMUM 5'-0" SEPARATION FROM EXHAUST TERMINATIONS TO OPERABLE WINOWS. 6. ALL UNLINE UCTWORK VISIBLE THOUGH THE AIR EVICE SHALL BE PAINTE FLAT BLACK. 7. CEILING TILES USE TO ACCESS FAN COIL UNITS TO BE LABELE. C CONVECTOR CC COOLING COIL CH CHILLER CP CONENSATE PUMP CRU CONENSATE RETURN UNIT CT COOLING TOWER CUH CABINET UNIT HEATER C UST COLLECTOR H EHUMIIFIER EBB ELECTRIC BASEBOAR EF EXHAUST FAN EH EXHAUST HOO EJ EXPANSION JOINT ET EXPANSION TANK EUH ELECTRIC UNIT HEATER F FILTER FCU FAN COIL UNIT F FLOOR RAIN FOP FUEL OIL PUMP FOT FUEL OIL TANK FTR FIN TUBE RAIATION MAU MAKE-UP AIR UNIT MCC MOTOR CONTROL CENTER P PUMP RAHU ROOFTOP AIR HANLING UNIT RCP RAIANT CEILING PANEL REF ROOF EXHAUST FAN RF RETURN FAN RH RELIEF HOO RTU ROOFTOP UNIT RV ROOF VENTILATOR SA SOUN ATTENUATOR SF SUPPLY FAN T TANK TXV THERMAL EXPANSION VALVE UH UNIT HEATER UST UNERGROUN STORAGE TANK UV UNIT VENTILATOR V VALVE VF VARIABLE FREQUENCY RIVE VP VACUUM PUMP 3-WAY CONTROL VALVE SQUARE/RECTANGULAR SUPPLY IFFUSER, GRILLE OR REGISTER ROUN IFFUSER RETURN REGISTER OR GRILLE (HORIZONTAL MOUNT) EXHAUST REGISTER OR GRILLE (HORIZONTAL MOUNT) SIEWALL REGISTER OR GRILLE WITH AMPER (UCT MOUNT) SUPPLY REGISTER OR GRILLE (VERTICAL MOUNT) EXHAUST OR RETURN REGISTER OR GRILLE (VERTICAL MOUNT) MECHANICAL SYMBOLS & ABBREVIATIONS M0.0

6 NO SCOPE OF MECHANICAL WORK A 90 6"Ø NEW UCTWORK B 90 6"Ø A 200 8"Ø (TYP.2) C RA 24X24 (TYP.2) 8X2 6X8 2X8 8X2 UCTWORK TO REMAIN. CONTRACTOR TO FIEL VERIFY. (TYPICAL) AIR EVICE SCHEULE FLOOR PLAN - MECHANICAL SCALE /8"= '0" MARK ESCRIPTION RAIATION AMPER OB AMPER MANUFACTURER A CEILING IFF NO NO TO REMAIN B CEILING IFF NO NO NEW - MATCH C RETURN AIR NO NO TO REMAIN. VERIFY ALL CEILING TYPES WITH ARCHITECTURAL RAWINGS. 2. ALL AIR EVICES SHALL BE ALUMINUM, UNLESS NOTE. A 000 0"Ø (TYP.2) IFFUSER/GRILLE MARK CFM NECK SIZE TYPICAL OF QUANTITY. ALL SUPPLY / RETURN AIR GRILLES ARE TO REMAIN UNLESS INICTE OTHERWISE. ALL GRILLES TO BE WIPE OWN CLEAN AN RE-INSTALLE WHERE PLAN INICATES. CONTRACTOR TO FIEL VERIFY ALL GRILLES. RE-BALANCE TO CFM INICATE. RE-CONNECT UCTWORK AS REQUIRE. 2. ALL NEW SUPPLY AIR GRILLES TO TAP TO SUPPLY UCT ABOVE CEILING. PATCH AN SEAL AIR TIGHT. RE-INSULATE TO MATCH AN BALANCE TO CFM AS INICATE. CONTRACTOR TO FIEL VERIFY EXACT LOCATION OF SUPPLY UCTS. REFER TO SCHEULE. M.0

7 ELECTRICAL SYMBOLS AN ABBREVIATIONS NOTE: NOT ALL SYMBOLS AN ABBREVIATIONS INICATE HERE ARE USE IN THE RAWINGS AN MAY NOT APPLY TO THIS PROJECT. AITIONAL SYMBOLS MAY BE INICATE IN THE RAWINGS. ELECTRICAL ABBREVIATIONS LIGHTING AN CONTROLS POWER AN COMMUNICATIONS GENERAL NOTES P 2P 3P 4P PW P2W 2P2W 2P3W 3P2W 3P3W 3P4W 4P4W A AC AF AFF AFG AIC AL AS AT ARCH ATS A/V B BF BLG C CAT CATV CB CKT CLG CT CU CL C ISC WG E EC EMT EWC EX FLA GC GFCI GFPE GN GRC HP HVAC Hz JB KVA KVAR KW LP LS LTG LV MCC MP MISC MLO MT MTG MTS N/A NC NEC NIC NO # NTS OH P PB PC PH PNL PR PRI PVC R REC RSC SEC SN SP SS ST STP SUSP SW SWB T TC TCI TEL/ATA TEL TYP UG UTP V UOI Y W WP XFMR ZAM +72 ONE POLE TWO POLE THREE POLE FOUR POLE ONE POLE, ONE WIRE ONE POLE, TWO WIRE TWO POLE, TWO WIRE TWO POLE, THREE WIRE THREE POLE, TWO WIRE THREE POLE, THREE WIRE THREE POLE, FOUR WIRE FOUR POLE, FOUR WIRE AMPERE ALTERNATING CURRENT AMP FRAME ABOVE FINISHE FLOOR ABOVE FINISHE GRAE AMPERE INTERRUPTING CAPACITY ALUMINUM AMP SWITCH AMP TRIP ARCHITECT AUTOMATIC TRANSFER SWITCH AUIO VISUAL PEESTAL MOUNTE ON BENCH TOP BELOW FLOOR BUILING CONUIT CATALOG CABLE TELEVISION CIRCUIT BREAKER CIRCUIT CEILING MOUNTE CURRENT TRANSFORMER COPPER CENTERLINE EICATE EVICE IRECT CURRENT ELTA ISCONNECT RAWING EMERGENCY ELECTRICAL CONTRACTOR ELECTRIC METALLIC TUBING ELECTRIC WATER COOLER FULL LOA AMPS GENERAL CONTRACTOR GROUN FAULT CIRCUIT INTERRUPTER GROUN FAULT PROTECTION EQUIPMENT GROUN GALVANIZE RIGI CONUIT HORSEPOWER HEATING, VENTILATING AN AIR CONITIONING HERTZ (cycle) PER SECON JUNCTION BOX KILOVOLT AMPERE KILOVOLT AMPERE REACTIVE KILOWATT LIGHTING PANELBOAR LIMIT SWITCH LIGHTING LOW VOLTAGE MOTOR CONTROL CENTER MAIN ISTRIBUTION PANEL MISCELLANEOUS MAIN LUGS ONLY MOUNTE MOUNTING MANUAL TRANSFER SWITCH NOT APPLICABLE NORMALLY CLOSE NATIONAL ELECTRIC COE NOT IN CONTRACT NORMALLY OPEN NUMBER NOT TO SCALE OH POLE PULL BOX PLUMBING SYSTEM CONTRACTOR PHASE PANELBOAR PAIR PRIMARY POLYVINYL CHLORIE CONUIT RELAY RECESSE RIGI STEEL CONUIT SECONARY SOLI NEUTRAL SPARE STAINLESS STEEL SHUNT TRIP SHIELE TWISTE PAIR SUSPENE SWITCH SWITCHBOAR TAMPER RESISTANT SAFETY RECEPTACLE TELEPHONE CABINET TELECOMMUNICATIONS CABLING INSTALLER TELEPHONE/ATA TELEPHONE TYPICAL UNERGROUN UNSHIELE TWISTE PAIR VOLT UNLESS OTHERWISE INICATE WYE WATT WEATHERPROOF TRANSFORMER ZONE AAPTER MOULE MOUNTING UNITS TO CENTERLINE ABOVE FINISHE FLOOR OR GRAE HT S K R VC T C PC LCP SURFACE MOUNTE LIGHT FIXTURES RECESS MOUNTE LIGHT FIXTURES WALL MOUNTE LIGHT FIXTURES SUSPENE, PENENT, CHAIN STEM, OR CABLE HUNG LIGHT FIXTURES SHAING INICATES FIXTURE FULLY WIRE TO EMERGENCY OR NIGHT LIGHTING CIRCUIT PARTIAL SHAING INICATES FIXTURE PARTIALLY WIRE TO EMERGENCY OR NIGHT LIGHTING CIRCUIT. REFER TO GENERAL NOTE #7. STRIP OR UNER CABINET LIGHT FIXTURE SINGLE HEA SPOT LIGHT OR FLOO LIGHT FIXTURE OUBLE HEA SPOT LIGHT OR FLOO LIGHT FIXTURE EXIT LIGHT FIXTURE - ARROWS AN FACE AS INICATE ON RAWINGS LIGHTING TRACK - LENGTH AS INICATE ON RAWING NUMBER OF FIXTURES AS INICATE ON RAWING AN/OR LIGHT FIXTURE SCHEULE EMERGENCY BATTERY REMOTE LIGHTING HEAS EMERGENCY BATTERY UNIT WITH LIGHTING HEAS SURFACE MOUNTE ACCENT LIGHT RECESS MOUNTE ACCENT LIGHT SINGLE POLE SWITCH - MOUNT 44" AFF UNLESS OTHERWISE NOTE SWITCH ESIGNATION SWITCH TYPE (2) OUBLE POLE (3) 3 WAY (4) 4 WAY (K) KEY OPERATE (P) WITH PILOT LIGHT INICATION (L) UAL LEVEL SWITCH (VC) VACANCY SENSOR LUTRON MS-OPS6M2-V-WH () LUTRON MAESTRO WIRELESS IMMER LOW VOLTAGE SWITCH OVERIE RELAY ESIGNATION LIGHTING CONTROL VACANCY SENSOR-CEILING MOUNTE LUTRON LRF2-OCR2B-P-WH TIME CLOCK - SEE SCHEULE ON SHEET# CONTACTOR - SEE SCHEULE ON SHEET# PHOTO CELL LIGHTING CONTROLLER PANEL LCP/ ESIGNATION G H N HA-,3,5/R X 2 PB J EPO PNL CIRCUIT HOME RUN WITH GROUN, HOT, NEUTRAL CIRCUIT TO BE PULLE THROUGH ESIGNATE RELAY IN LIGHTING CONTROL PANEL (IF APPLICABLE) CIRCUITING INFORMATION FOR GROUPING PURPOSES ONLY. CONTRACTOR SHALL SELECT ACTUAL CIRCUIT BREAKERS AN BALANCE LOAS IN PANELBOAR. PANELBOAR INFORMATION. SEE SCHEULING SHEETS FOR MORE INFORMATION. UPLEX RECEPTACLE - MOUNTE 8" AFF UNLESS OTHERWISE NOTE TAMPER PROOF UPLEX RECEPTACLE - MOUNTE 8" AFF UNLESS OTHERWISE NOTE GFCI UPLEX RECEPTACLE - MOUNTE 8" AFF UNLESS OTHERWISE NOTE UPLEX RECEPTACLE - MOUNTE 6" ABOVE COUNTER BACKSPLASH UNLESS OTHERWISE NOTE QUA RECEPTACLE - MOUNTE 8" AFF UNLESS OTHERWISE NOTE UPLEX RECEPTACLE - MOUNTE FLUSH IN CEILING FLOOR MOUNTE ELECTRICAL BOX SEE RAWINGS FOR TYPES OF OUTLETS REQUIRE AT EACH BOX (F) FLUSH TYPE (P) POKE THRU TYPE PUSHBUTTON SPECIAL PURPOSE OUTLET - THIS ELECTRICAL CONNECTION REQUIRES ONSITE COORINATION WITH OTHER CONTRACTORS AN/OR VENORS PRIOR TO INSTALLATION. PROVIE ALL CONNECTIONS, MOTOR STARTERS, AN ISCONNECTS REQUIRE BY COE AN FINAL SUGGESTE MANUFACTURER REQUIREMENTS. CONTACT ENGINEER WITH ANY REQUIRE CHANGES TO ELECTRICAL ESIGN. MOTOR CONNECTION (2) MOTOR IENTIFICATION PANELBOAR - FLUSH MOUNTE PANELBOAR - SURFACE MOUNTE TRANSFORMER - MOUNT ON 4" PA UNLESS OTHERWISE NOTE IN-GRAE PULLBOX ISCONNECT SWITCH FUSE ISCONNECT SWITCH COMBINATION MOTOR STARTER MOTOR RATE SWITCH JUNCTION BOX OUBLE ACTION MUSHROOM HEA EMERGENCY POWER OFF BUTTON. THIS BUTTON SHALL PROVIE A SIGNAL TO SHUNT TRIP ALL CIRCUIT BREAKERS WHICH FEE POWER TO THIS ROOM. ALL CIRCUIT BREAKERS FEEING THIS ROOM SHALL BE SHUNT TRIP TYPE. TELEPHONE/ATA OUTLET - PROVIE SINGLE GANG BOX AN " CONUIT WITH PULL STRING TO NEAREST ACCESSIBLE CEILING. PANELBOAR ESIGNATION. ALL WORK SHALL BE PERFORME IN A NEAT AN WORKMANLIKE MANNER AN SHALL COMPLY WITH ALL AOPTE LOCAL, STATE, AN NATIONAL COES. 2. ALL ELECTRICAL WORK REQUIRES CITY INSPECTION. ELECTRICAL WORK COVERE OR ENCLOSE PRIOR TO CITY INSPECTION SHALL BE UNCOVERE FOR INSPECTION AN REPLACE AT NO EXPENSE TO THE OWNER. 3. ALL CONUITS MUST CONTAIN A GROUN WIRE. USE OF THE CONUIT BOY AS A GROUNING METHO IS PROHIBITE. 4. ALL CONUITS SHALL BE INSTALLE PARALLEL AN/OR PERPENICULAR TO BUILING LINES. 5. ALL CONUCTORS SHALL BE COPPER UNLESS SPECIFIE OTHERWISE. 6. O NOT SCALE THE RAWINGS. 7. ELECTRICAL CONUITS AN/OR CIRCUITS PENETRATING FIRE RATE CEILING AN WALLS TO BE SEALE FIRE AN SMOKE TIGHT AT THE PENETRATION. 8. THE CONTRACTOR SHALL REPLACE AN/OR REPAIR ALL WALLS, CEILINGS, OORS, EQUIPMENT, WIRING, CONUIT, ETC, WHICH ARE AMAGE OR REMOVE BY CONTRACTOR TO THE SATISFACTIONS OF THE ARCHITECT/ENGINEER. 9. ALL MATERIALS SHALL BE NEW AN UNUSE, AN OF THE BEST QUALITY. ALL MATERIAL INSTALLE SHALL BE IL LISTE OR AS REQUIRE BY LOCAL BUILING COES. 0. VERIFY VOLTAGE, CURRENT AN PHASES FOR ALL EQUIPMENT TO BE INSTALLE INCLUING BY OWNER.. THE CONTRACTOR SHALL PROVIE ALL FUSES AN CIRCUIT BREAKERS WHERE REQUIRE BY THE NEW CONSTRUCTION OCUMENTS. 2. ALL ELECTRICAL CABINETS, PANELS, ISCONNECTS, TRANSFORMERS, CONTROLS, RECEPTACLES, J-BOXES, ETC., SHALL BE MARKE, TAGGE AN IENTIFIE. NOTE FEEER SOURCE WHERE APPLICABLE. 3. CONTRACTOR SHALL PROVIE ALL MATERIALS EXCEPT AS NOTE AN MAKE ALL NECESSARY CONNECTIONS TO NEWLY INSTALLE EQUIPMENT. 4. UPON COMPLETION OF THE PROJECT, ALL CHANGES SHALL BE OCUMENTE, AN RELINE. AS-BUILT RAWINGS SHALL BE TURNE OVER TO THE OWNER BY THE CONTRACTOR. 5. 4" HOUSEKEEPING CONCRETE PAS SHALL BE FURNISHE FOR ALL FLOOR MOUNTE EQUIPMENT, BY OTHERS. 6. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING A BI TO VERIFY CONITIONS. BY SUBMITTING A BI THE CONTRACTOR ACKNOWLEGES THAT HE HAS VISITE THE SITE AN THE BI IS AEQUATE TO PERFORM WORK NECESSARY TO MAKE THE SYSTEMS COMPLETE AN OPERATIONAL. IF THE CONITIONS AT THE SITE ARE NOT SUCH THAT THE WORK CAN BE INSTALLE AS SHOWN, CONTRACTOR'S BI SHALL INCLUE COST, TO COVER NECESSARY AJUSTMENTS AN AITIONS, (BASE ON SITE CONITIONS) TO MAKE THE SYSTEMS COMPLETE AN OPERATIONAL. CONTRACTOR TO CONTACT ARCHITECT/ENGINEER WITH ANY FIEL ISCREPANCIES. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH IBC BY HAVING SELECTE LIGHTING MANUFACTURER SUBMIT EMERGENCY PHOTOMETRIC PLAN WITH LIGHTING SUBMITTAL SHOWING COMPLIANCE, AN AING AITIONAL FIXTURES WHERE REQUIRE AT NO COST TO THE OWNER. ELECTRICAL SYMBOLS & ABBREVIATIONS E0.0

8 3 A C C S S S S 2 SS S 3 A S B KEYE NOTES 2 3 WIRE WITH LIGHTING CIRCUIT IN THIS AREA. LIGHTS SWITCHES MOUNTE ON ESKTOP (FLUSH MOUNTE). FIEL COORINATE EXACT MOUNTING LOCATION BEFORE ROUGH-IN. INSTALL LIGHT-TO-ESK CONTROL WIRING IN OVERFLOOR RACEWAY. (REFERENCE POWER PLAN) LIGHTING IN THIS ROOM IS TO REMAIN. FLOOR PLAN - LIGHTING SCALE /8"= '0" E.0

9 NOTE: CIRCUITING SHOWN IS FOR GROUPING PURPOSES ONLY. CONTRACTOR SHALL VERIFY SPARE CIRCUITS AFTER EMOLITION. REUSE CIRCUITS AN CONUCTORS WHERE AVAILABLE. VERIFY CONITION OF CONUCTORS. 3 6 L2CC- L2CC TV 6 5 H2A L2CC XFMR XFMR T4 T3 3 L2A L2B 7 L2CC-5 TV L2CC- 4 EX L2CC-7 L2CC-9 2 KEYE NOTES MOUNT 20A TWIST LOCK OUTLETS FOR UPS EQUIPMENT. LOCATE ABOVE TMC RACK UNER LAER TRAY. THE FOLLOWING IS A LIST OF MATERIALS TO BE PROVIE AN INSTALLE BY THE ELECTRICAL CONTRACTOR: 2 PROVIE WALL MOUNTE RECEPTACLE WITH A/V OPENING. MOUNT 5'-5" ABOVE FINISH FLOOR TO CENTER OF OUTLET.. () OVERFLOOR BOX - 4 GANG BOX 2. () OVERFLOOOR UPLEX SERVICE EVICE PLATE + ELECTRICAL OUTLET (LIVE AN WIRE) 3 4 ALL ELECTRICAL PANELS ARE TO REMAIN. PROVIE (4) ATA ROPS AT THIS LOCATION. 3. (3) OVERFLOOR COMMUNICATIONS EVICE PLATE (WITH AAPTOR INSERTS EFINE BELOW) 5 PROVIE LEGRAN WIREMOL WALK OVER COVER FOR PROTECTION OF CABLE RUN TO ESK. PROVIE LEGRAN OFR SERIES IN WALL ENTRANCE EN FITTING #OFR0IW. EXTEN FROM UPPER LEFT HAN CORNER OF ESK TO NORTH WALL. COORINATE FINAL LOCATION WITH FURNITURE BEFORE ROUGH-IN. WIREMOL COMMUNICATIONS MOULES (OR EQUAL) - ATA SHEETS ATTACHE. (5) CM2-U2TJ - WIREMOL CM SERIES UAL FLUSHMOUNT INSERT 2. () CM2-BL - WIREMOL CM SERIES BLANK INSERT 3. (8) CAT6 RJ45 MOULAR NETWORK JACK CONNECTORS FLOOR PLAN - POWER/ATA SCALE /8"= '0" 6 7 PROVIE COOPER B-LINE BCH2 CABLE HOOK EVERY 4' TO 5' TO SUPPORT COMMUNICATION CABLING. MONITORS ARE MOUNTE HIGH ON THE WALL AN RESPECTIVE POWER AN ATA BOX IS MOUNTE BEHIN MIRROR. PROVIE LOW VOLTAGE MEIA PLATE (ATACOMM ELECTRONICS # SB). COORINATE WITH ARCHITECT FOR EXACT MOUNTING HEIGHT. 4. () 3.5MM ANALOG MOULAR AUIO JACK 5. () MOULAR JACK BLANK ELECTRICAL CONTRACTOR TO WIRE ALL CAT 6 CABLES. REFER TO E3.0 FOR CUT SHEETS. E.

10 PANEL H2A /2"C WITH 4 - #4, - #8 GN THWN COPPER Δ Y XFMR T 45KVA 480V, 3PH, 3W PRI 208Y / 20V, 3PH, 4W SEC AVAIL. AIC: "C WITH 4 - /0, - #6 GN THWN COPPER PANEL L2A NOTE: CIRCUITING SHOWN IS FOR GROUPING PURPOSES ONLY. CONTRACTOR SHALL VERIFY SPARE CIRCUITS AFTER EMOLITION. REUSE CIRCUITS AN CONUCTORS WHERE AVAILABLE. VERIFY CONITION OF CONUCTORS. AVAIL. AIC: 3503 PANEL L2B "C WITH 4 - #6, - #0 GN THWN COPPER ELECTRICAL SCHEULES & ETAILS E2.0

11 E3.0

AGORA PALM UNIT TYPE A2, A2A, A2B, A2C, A2D, A2F, A2G, A2H, A2J UNIT TYPE A1 & A1-A UNIT TYPE A3-A, A3B, A3C, A3E, A3F, A3H UNIT TYPE A4, A4A

AGORA PALM UNIT TYPE A2, A2A, A2B, A2C, A2D, A2F, A2G, A2H, A2J UNIT TYPE A1 & A1-A UNIT TYPE A3-A, A3B, A3C, A3E, A3F, A3H UNIT TYPE A4, A4A F- RF 0 Winding Way Round Rock Texas 7-970-97 Ph UNIT TYPE A & A-A BEROOM /" = '-0" LIVING UNIT TYPE A, AA, AB, AC, A, AF, AG, AH, A BEROOM /" = '-0" UNIT TYPE A-A, AB, AC, AE, AF, AH LIVING PROVIE SECURITY

More information

Ho-Chunk Gaming THUNDERBIRD ENGINEERING, INC. MILWAUKEE: (414) MADISON: (608)

Ho-Chunk Gaming THUNDERBIRD ENGINEERING, INC. MILWAUKEE: (414) MADISON: (608) Ho-Chunk Gaming POWER SYMBOLS X ELECTRICAL PANEL - REFER TO DRAWINGS FOR WIDTH AND PANEL SCHEDULES PANEL NAMING: XXP-#X: DENOTES PANEL FUNCTION: L = LIGHTING P = GENERAL POWER E = EMERGENCY S = OPTIONAL

More information

Technical Assignment 3 11/15/04. Executive Summary

Technical Assignment 3 11/15/04. Executive Summary Executive Summary This report is an analysis of the existing systems within the Outreach Innovation Building in University Park, PA. One significant design criteria was a lower than average noise criteria

More information

TOKISTAR LIGHTING INSTRUCTION MANUAL. Advantage Series. Xenon Lamp. Socket. Side View. 2.4 O.C. (60 mm) 3 O.C. (75 mm) 4 O.C. (100 mm) 6 O.C.

TOKISTAR LIGHTING INSTRUCTION MANUAL. Advantage Series. Xenon Lamp. Socket. Side View. 2.4 O.C. (60 mm) 3 O.C. (75 mm) 4 O.C. (100 mm) 6 O.C. TOKISTAR LIGHTING INSTRUCTION MANUAL Avantage Series General escription Tokistar s Avantage Series is a 24 VAC lighting system using LE moules or rigi-loop xenon lamps. LEs are 0.72 watts. Xenon lamps

More information

GRILLE, REGISTER AND DIFFUSER SCHEDULE

GRILLE, REGISTER AND DIFFUSER SCHEDULE ROOFTOP UNIT SCHEDULE (NATURAL GAS HEAT) MARK MANUFACTURER MODEL SUPPLY FAN COOLING COIL HEAT EXCHANGER MIN. MIN. MCA MOCP V/PH WEIGHT NOTES FAN CFM MIN ESP REFR. TH SH EAT LAT MIN. OUTPUT MIN. EFF. NOM.

More information

CT CABINET AND UTILITY METERING WELL AND BOOSTER PUMP CONTROL 12"x12" WIREWAY 200A MCB 200A, 120/208V, 3Ø, 4W BOARD TVSS CIA ALARM 400A, DOUBLE-THROW SWITCH PORTABLE GENERATOR CONNECTION ENCLOSURE EXISTING

More information

FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED. x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. CAPITAL LETTER DENOTES TYPE, LOWER CASE LETTER DENOTES SWITCH LEG. FLUORESCENT STRIP LIGHT FIXTURE,

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

AIR HANDLER DESIGN WORK SHEET

AIR HANDLER DESIGN WORK SHEET AIR HANDLER DESIGN WORK SHEET JOB Project: Date Representative Unit Model No. of Units Unit Tag(s) UNIT CONSTRUCTION UNIT ARRANGEMENT: [ HORIZ VERT] [ INDOOR OUTDOOR] [ BASE MTD CEILING HUNG CURB MTD]

More information

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 7 Rosemex Products 97 VENTILATION CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS 2 INTRODUCTION Rosemex "Penthouse" units are essentially outdoor mechanical rooms. They group in one compact weather proof outdoor

More information

FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED. x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. FLUORESCENT STRIP LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. WALL BRACKET FLUORESCENT

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

Submittal Summary Page

Submittal Summary Page ate 05/24/2011 Project Name ouglas Middle School Project Number Client / Purchaser Submittal Summary Page Qty Tag # Model # escription 1 RTU- Cafeteria 15 Ton, Johnson Controls Series 20 Single Packaged

More information

Steam Trap. Assist Trap Radiator Trap Radiator Valve

Steam Trap. Assist Trap Radiator Trap Radiator Valve Assist Trap Raiator Trap Raiator Valve /Assist Trap Selection 0.3 0.5 0.7 1.0 150 160 170 220 231 232 231 233 TF-1 TFA-2000 TF-2 TB-5 1.0 2.0 4.2 183 220 425 228 228 229 229 227 227 226 TSD-7 TSD-7F TS-7

More information

MONROE MIDDLE SCHOOL SCHOOL

MONROE MIDDLE SCHOOL SCHOOL MONROE MIDDLE SCHOOL SCHOOL MONOE MIDDLE SCHOOL EUGENE, OR 97401 C001 COVER SHEET M001 MECHANICAL NOTES, SYMBOLS & ABBREVIATIONS M100 MECHANICAL PARTIAL PLANS DEMOLITION M101 MECHANICAL PARTIAL PLANS NEW

More information

City of Duluth Festival Center 04/25

City of Duluth Festival Center 04/25 SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

TABLE LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS ASHRAE Uncovered Parking Areas. Building Grounds. Walkways 10 feet wide or greater

TABLE LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS ASHRAE Uncovered Parking Areas. Building Grounds. Walkways 10 feet wide or greater TABLE 9.4.5 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS ASHRAE 90.1 Uncovered Parking Areas Parking Lots and drives Building Grounds Walkways less that 10 feet wide Walkways 10 feet wide or greater

More information

EXHAUST FAN SCHEDULE

EXHAUST FAN SCHEDULE DUCTWORK SCHEDULE CONCEALED SUPPLY AIR RECTANGULAR, RTU CONCEALED SUPPLY AIR RECTANGULAR, ERV CONCEALED SUPPLY AIR ROUND, RTU CONCEALED SUPPLY AIR ROUND, ERV EXPOSED SUPPLY AIR ROUND RUNOUTS RETURN AIR

More information

Coastal Carolina University Brooks Stadium Additions - Phase 2

Coastal Carolina University Brooks Stadium Additions - Phase 2 FOO SERVICE EQUIPMENT, NOT IN CONTRACT. INFORMATION PROVIE TO ASSIST THE ROUGH IN OF WORK INICATE UNER OTHER IVISIONS COPYRIGHT 07 STUBBS MULROW HERIN ARCHITECTS, inc. 400 HIBBEN STREET MOUNT PLEASANT

More information

COMMERCIAL AIR HANDLER

COMMERCIAL AIR HANDLER COMMERCIAL AIR HANDLER FORM NO. H11-532 Featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant RHGM- 090 & 120 SERIES NOMINAL SIZES 7.5 & 10, TONS [26 & 35 kw] TABLE OF CONTENTS Unit Features...3

More information

COMMERCIAL AIR HANDLER

COMMERCIAL AIR HANDLER COMMERCIAL AIR HANDLER FORM NO. H11-529 REV. 6 Supersedes Form No. H11-529 Rev. 5 Featuring Industry Standard R-410A Refrigerant RHGL- 090, 120, 180 & 240 SERIES NOMINAL SIZES 7.5, 10, & 20 TONS [26, 35,

More information

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Greenheck Coils. A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs 3/8, 1/2 and 5/8 inch OD Tubing March 2010 Custom Coils Custom Coils Configured to Meet Your Needs Greenheck is proud to offer a complete

More information

GEZE DOOR TECHNOLOGY GEZE TS 1500 / TS 2000 / SYSTEM TS 4000 OVERHEAD DOOR CLOSERS WITH LINK ARM BEWEGUNG MIT SYSTEM

GEZE DOOR TECHNOLOGY GEZE TS 1500 / TS 2000 / SYSTEM TS 4000 OVERHEAD DOOR CLOSERS WITH LINK ARM BEWEGUNG MIT SYSTEM GEZE DOOR TECHNOLOGY OVERHEAD DOOR CLOSERS WITH LINK ARM BEWEGUNG MIT SYSTEM Cover photo: Robert Les, photo on page 2: GEZE GmbH Overhea oor closers with link arm CONTENTS Overview table 4 Technics 6 Prouct

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs 5/16, 3/8, 1/2, 5/8 and 1 inch OD Tubing April 2016 Custom Coils Custom Coils Configured to Meet Your Needs Greenheck is proud to offer

More information

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series 1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series Rated in accordance with ARI Standard 210. Certification applies only when used with proper components as listed with ARI. FEATURES Designed as an upflow indoor

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES LIGHT LEVEL REQUIREMENTS LOCATION Classrooms and instrumental areas- Study Halls, Lecture Rooms, Art Rooms, Offices, Libraries, Conference Rooms, Work Rooms, Shops, Laboratories and Secondary School Cafeterias.

More information

Appendix B. Symbols for Drawings. Table B.1. Air moving devices and ductwork symbols. Air Movement. Fans. Axial flow fan.

Appendix B. Symbols for Drawings. Table B.1. Air moving devices and ductwork symbols. Air Movement. Fans. Axial flow fan. Appendix B Symbols for Drawings Table B.1 Air moving devices and ductwork symbols Air Movement Fans Axial flow fan Centrifugal fan Propeller fan Intake roof ventilator (supply) Exhaust roof ventilator

More information

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing

Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs. 3/8, 1/2 and 5/8 inch OD Tubing Greenheck Coils A Complete Line of Custom Coils to Meet Your Needs 3/8, 1/2 and 5/8 inch OD Tubing April 2012 Custom Coils Custom Coils Configured to Meet Your Needs Greenheck is proud to offer a complete

More information

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

GEZE DOOR TECHNOLOGY GEZE TS 1500 / TS 2000 / SYSTEM TS 4000 OVERHEAD DOOR CLOSERS WITH LINK ARM BEWEGUNG MIT SYSTEM

GEZE DOOR TECHNOLOGY GEZE TS 1500 / TS 2000 / SYSTEM TS 4000 OVERHEAD DOOR CLOSERS WITH LINK ARM BEWEGUNG MIT SYSTEM GEZE DOOR TECHNOLOGY OVERHEAD DOOR CLOSERS WITH LINK ARM BEWEGUNG MIT SYSTEM Cover photo: Robert Les, photo on page 2: GEZE GmbH Overhea oor closers with link arm CONTENTS Overview table GEZE System TS

More information

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION

HVAC LEGEND HVAC ABBREVIATIONS PLUMBING LEGEND PLUMBING ABBREVIATIONS PRELIMINARY NOT FOR CONSTRUCTION GENERAL NOTES SPECIFICATIONS LEGEND SYMBOL DESCRIPTION ABBREV. SYMBOL DESCRIPTION ABBREV. SYMBOL DESCRIPTION ABBREV. ABBREVIATIONS PLUMBING LEGEND SYMBOL DESCRIPTION ABB. SYMBOL DESCRIPTION ABB. SYMBOL

More information

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED SYMBOLS AND ABBREVIATIONS ABBREVIATIONS GENERAL NOTES LINE TYPE LEGEND CIRCUITS TELECOMMUNICATION SYSTEM ING EQUIPMENT POWER DEVICES FIRE ALARM SYSTEM NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

More information

TYPICAL PLUMBING SYMBOLS SAN SAN GARAGE DRAIN COLD WATER HOT WATER WATER METER GAS METER GAS BALL VALVE CHECK VALVE VENT BFP BFP EXP EXP

TYPICAL PLUMBING SYMBOLS SAN SAN GARAGE DRAIN COLD WATER HOT WATER WATER METER GAS METER GAS BALL VALVE CHECK VALVE VENT BFP BFP EXP EXP NO2 9 ENERAL MECHANICAL-ELECTRICAL SPECIFICATIONS: 1. ALL WORK SHALL BE ONE IN STRICT CONFORMANCE WITH THE LOCAL BUILIN COES. 2. ALL MATERIALS SHALL BE NEW, FIRST CLASS, AN INSTALLE TO MANUFACTURER'S WRITTEN

More information

SAS Steadyair Make-Up Air Units Technical Guide

SAS Steadyair Make-Up Air Units Technical Guide TGSAS-3 SAS Steadyair Make-Up Air Units Technical Guide A COMPLETE AIR TEMPERING PACKAGE FOR COMMERCIAL, INSTITUTIONAL, AND INDUSTRIAL APPLICATIONS S ince 1875, the L.J. Wing Company has been a leader

More information

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings 1 T Consultant: NOTES, SYMBOLS & ABBREVIATIONS - MECHANICAL Number Description M001 Vestibule 117 LAN/IT Coffee 115 116 Mail Room 118 114 113 112 Scanning 119 Open Office 101 FIRST FLOOR PLAN - MECHANICAL

More information

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1. MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient

More information

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 Product Data A10097 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 60,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-019 TABLE OF CONTENTS DESIGN & SPECIFICATIONS...3 APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL DATA... 5 SPECIFICATIONS...

More information

1.1 This section applies to air handling units for HVAC Systems.

1.1 This section applies to air handling units for HVAC Systems. AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling

More information

Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A

More information

SHOE PALACE HUNTINGTON PARK M.200

SHOE PALACE HUNTINGTON PARK M.200 M.200 SPLIT SYSTEM CONDENSING UNIT SCHEDULE MARK SERVICE MODEL NO. COOLING DIMENSIONS ELECTRICAL REMARKS CAPACITY AMBIENT DB REFRIGERANT LENGTH WIDTH HEIGHT WEIGHT VOLT/PHASE MCA MOP (MBH) (DEG F) (IN)

More information

JH Series Installation

JH Series Installation JH Series Installation Space Heating / Fresh Air Make-Up From the Manufacturers of Hi-Velocity Systems TM Includes: JH-15 JH-30 Module-JH-Series-Installation-Manual-010118 Installation JH fan coils by

More information

Heat Recovery Units. EXTERNAL STATIC REQUIRED (in.h2o) (Pa) MOTOR (Bhp/Hp) (bkw/kw) SPEED (rpm)

Heat Recovery Units. EXTERNAL STATIC REQUIRED (in.h2o) (Pa) MOTOR (Bhp/Hp) (bkw/kw) SPEED (rpm) Heat Recovery Units AIR HANDLING UNIT No. SERVICE AREA MANUFACTURER MODEL HRU-3 & HRU-4 B-Section Low Rate Ventilation Tempeff RG 16000 (9500) SUPPLY FAN - SIZE/TYPE AIRFLOW RATE (cfm) (l/s) TOTAL STATIC

More information

Liebert PDX and PCW Thermal Management Systems

Liebert PDX and PCW Thermal Management Systems Liebert PDX and PCW Thermal Management Systems 3 to 8 Ton (11 to 29 kw) Nominal Capacity, Upflow and Downflow, 60 Hz, Air-, Water-, Glycoland Chilled-water-cooled Models System Design Catalog Technical

More information

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit, 1.5 to 5.0 ton unit ELECTRICAL RANGE: 40 -va, 208/230

More information

Technical Development Program

Technical Development Program Technical Development Program PRESENTED BY: James Parker Insert your logo here AIR HANDLERS Coils: Direct Expansion Chilled Water and Heating Menu Section 1 Introduction Section 2 Typical Coil Applications

More information

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 Product Data FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE: 40 -va, 208/230 -v transformer, 60 Hz, 1 Phase. FAN MOTOR: 2 -speed

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

KIC Air Curtains. Technical Guide

KIC Air Curtains. Technical Guide TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS Product Data FF1DNA, FF1DNE Fan Coil Units Sizes 018 thru 030 FF1D FEATURES/BENEFITS The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air

More information

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat) ENGINEERING DATA COILS BLOWER COIL UNITS B24/C22/24 B24 SERIES ADD-ON BLOWER UNITS UP-FLO DOWN-FLO HORIZONTAL WITH C22FC/CR22/CH22 & C24FC/CH24 COILS 1-1/2 Thru 5 Ton (5.3 thru 17.6 kw) Capacity 6,400

More information

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS

COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER UNITS, 6 20 TONS Product Specifications COMMERCIAL PACKAGED HEAT PUMP AIR HANDLER S, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without modification.

More information

Digital Inverter 4 series 8 & 10HP

Digital Inverter 4 series 8 & 10HP E6-H Digital Inverter 4 series 8 & 0HP High static duct type Indoor unit RAV-SM2244DTP-E RAV-SM2804DTP-E Outdoor unit RAV-SM2244AT8-E RAV-SM2804AT8-E Contents. Line up... 2. Indoor unit (High static duct

More information

COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY. Convectors STEAM AND HOT WATER RADIATION CC-13

COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY. Convectors STEAM AND HOT WATER RADIATION CC-13 COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY Convectors STEAM AND HOT WATER RADIATION CC-13 Sterling Convectors are engineered for both forced hot water and two-pipe steam heating system installation

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

MAC N-407 Air-Cooled Chiller

MAC N-407 Air-Cooled Chiller MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=

More information

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

TCV-1. Convector Steam and Hot Water Unit Heaters

TCV-1. Convector Steam and Hot Water Unit Heaters TCV-1 Convector Steam and Hot Water Unit Heaters Convector Radiation Turbonics Convectors are engineered for both forced hot water and two-pipe steam heating system installation with heating elements of

More information

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 18,000

More information

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil MHCFC4W-16-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.1 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 48,000 BTUH Multiaqua

More information

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil MHCFC4W-04-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 12,000 BTUH Multiaqua

More information

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil MHCFC4W-08-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.1 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER PROJECT NO. CWA 2013-04 SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER BIDS RECEIVED: CITY HALL, CITY OF BESSEMER TIME: 2:00pm DATE: October 2, 2014 City of Bessemer --------------------------------------------------------------------------------------------------------------------------------------------

More information

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

General Description. Operation

General Description. Operation ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication

More information

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2 Service Literature Corp. 0527 L10 Revised May 2011 CB26UH and CBX26UH Series Table of Contents CB26UH CBX26UH Model Number Information................... 2 Specifications / Electrical Data................

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

Architectural Alliance Incorporated MDP CONSULTING ENGINEERS, INC N 11th Street Beaumont, TX 77702

Architectural Alliance Incorporated MDP CONSULTING ENGINEERS, INC N 11th Street Beaumont, TX 77702 04/08/2013 last saved: TRENT plotted: DRAWN BY: TLH CHECKED BY: DWD 04/08/2013 last saved: DMCPHERSON plotted: DRAWN BY: TLH CHECKED BY: DWD 04/08/2013 last saved: DMCPHERSON plotted: DRAWN BY: TLH CHECKED

More information

NEW CHILLER SCHEDULE

NEW CHILLER SCHEDULE TITLE: REPLACE CHILLER MACC MAXIMO # 4542690 PROJECT # 14M108CN MACC # 14-0459 ATTACHMENTS: 1. MAXIMO Equipment update form SCOPE OF WORK: The contractor shall provide all material, labor, equipment, and

More information

CUH-11 CABINET UNIT HEATERS

CUH-11 CABINET UNIT HEATERS CUH- CABINET UNIT HEATERS Steam and Hot Water CABINET UNIT HEATERS SELECTION AND "ROUGH IN" MADE EASY - ONLY THE LENGTHS VARY The Beacon-Morris Cabinet Unit Heater is the industry s most recent design.

More information

MACH N-407 Heat Pump Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type

More information

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT

More information

Concealed Ducted Split Series R-407C MBH

Concealed Ducted Split Series R-407C MBH Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY

More information

Please refer to the drawing and notes for each particular plan view. Site Plan S1-1 Site Drawing. Electrical E1-1 Main Electrical Drawing

Please refer to the drawing and notes for each particular plan view. Site Plan S1-1 Site Drawing. Electrical E1-1 Main Electrical Drawing The property that I discuss is an actual property that I helped to build. My position was as the Facility/Project Manager while the building was under construction. I worked very closely with the Senior

More information

HVAC HEATING PRODUCTS

HVAC HEATING PRODUCTS GTFC-7 HVAC HEATING PRODUCTS Application Manual SF/SC Series TF/TC Series GG Series TUBULAR GAS-FIRED UNIT HEATERS Contents PAGE GENERAL INFORMATION All Series 2 GG SERIES Standard/Optional Features 3

More information

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN Introduction to HVAC Agenda Psychrometrics Human Comfort Heat Transfer Refrigeration Cycle HVAC Terminology HVAC Systems Introduction to HVAC Psychrometrics 2000 TRG-TRC002-EN Properties of Air Dry-bulb

More information

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS 230500 HVAC BASIC MATERIAL AND METHODS PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 230000 Basic HVAC Requirements B. Section 230523 Valves C. Section 230510 Chilled

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

CADDY CORPORATION. Utility Distribution Systems

CADDY CORPORATION. Utility Distribution Systems Food Service Equipment Air Systems Utility Distribution Systems page 1 of 2 Equipment Specifications General Specifications Caddy Corporation of America Energy Distribution and Management System, which

More information

G101 SCHOOL AIR CONDITIONING UPGRADE - PROJECT #3 SUNSET ELEMENTARY COOLING UPGRADE 2014 NORTH 250 WEST SUNSET, UTAH 84015

G101 SCHOOL AIR CONDITIONING UPGRADE - PROJECT #3 SUNSET ELEMENTARY COOLING UPGRADE 2014 NORTH 250 WEST SUNSET, UTAH 84015 DRAWING INDEX GENERAL G0 PLUMBING P00 P0A P0B P0C P0A P0A P0B COVER SHEET PLUMBING LEGEND AND GENERAL NOTES PLUMBING PLAN PLUMBING PLAN PLUMBING PLAN PLUMBING ROOF DEMOLITION PLAN PLUMBING ROOF REMODEL

More information

Call us today! (800)

Call us today! (800) 500 TON AIR-COOLED CHILLER PA-ACCTR-500 Call us today! (800)341-4297 The 500-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

DRAWING SCHEDULE TAB REQUIREMENTS BY EQUIPMENT TYPE TYPE OF EQUIPMENT DESCRIPTION COMPONENT TAB REQUIREMENTS

DRAWING SCHEDULE TAB REQUIREMENTS BY EQUIPMENT TYPE TYPE OF EQUIPMENT DESCRIPTION COMPONENT TAB REQUIREMENTS DRAWING SCHEDULE NUMBER TITLE M0-1 MECHANICAL NOTES AND LEGEND M1-0 MECHANICAL FLOOR PLAN M4-0 MECHANICAL SCHEDULES M4-1 MECHANICAL LOAD CALCULATIONS M5-0 MECHANICAL DETAILS M8-0 TCS BASYS CONTROLS DRAWINGS

More information

I. Introduction and Arrangement

I. Introduction and Arrangement Joseph Firrantello - Mechanical Option Primary Faculty Consultant: Freihaut Laboratory Facility, Eastern Pennsylvania Mechanical Assignment 3 Existing Conditions Report 11.14.03 Executive Summary The purpose

More information

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings. SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.

More information

technical guide Water-Cooled Self-Contained Units

technical guide Water-Cooled Self-Contained Units technical guide Water-Cooled Self-Contained Units C-Series, Vertical Technical Guide: YK145.00-EG3 (710) TABLE OF CONTENTS Water-Cooled Self-Contained Units Introduction...............................................................................

More information

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE COMMERCIAL SPLIT SYSTEMS HT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, SY TO INSTALL AND SERVICE Single stage cooling capacity control on all models All models utilize round copper tube, aluminum plate

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Entire document - mgl44 PART 1 - INTRODUCTION 1.1 PURPOSE A. This section is intended to define the general installation and minimum product

More information

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation. Brochure# 228E 122011 TYPE VSA SEWAGE PUMP Capacities to 100 gpm, Heads to 120, Horsepower range 3/ thru 0, 3 thru discharge, 1750 and 1150 operation. HIGHLIGHTS Wet-Pit Installations Pumps Suspend From

More information

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC PART 1 GENERAL 1.01 RELATED REQUIREMENTS SECTION 23 0913 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC A. Section 26 2717 - Equipment Wiring: Electrical characteristics and wiring connections. 1.02 ADMINISTRATIVE

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information