Preconfigured heat interface unit with compact installation depth for preparation of domestic hot water and apartment heating.

Size: px
Start display at page:

Download "Preconfigured heat interface unit with compact installation depth for preparation of domestic hot water and apartment heating."

Transcription

1 T T TACOTHERM DUAL PIKO HEAT INTERFACE UNIT ADVANTAGES Compact installation depth Large number of variants Preconfigured for simple installation On-demand, hygienic preparation of domestic hot water Demand-driven calculation of energy costs Preconfigured heat interface unit with compact installation depth for preparation of domestic hot water and apartment heating. DESCRIPTION The heat interface unit in the Piko series suits practically any installation situation thanks to its compact installation depth and versatile constructions. The stations are available as individual fresh hot water modules or heating modules as well as combination stations. Various selectable hydraulic components ensure on-demand preparation of domestic hot water, distribution of heat energy as well as calculation of energy costs. SYSTEM/BASIC DIAGRAM INSTALLATION The heat interface units can be installed as a compact station or in a split design. For ease of transport, the compact version can be dismantled conveniently into two parts and reassembled using the available plug connection. Ideally the station should be placed next to the outlets for the apartments. The individual modules can be assembled horizontally as well as installed at separate locations in the split design. OPERATION The heat interface units in the Piko series are designed for preparation of domestic hot water and distribution of heat energy in multistory residential buildings. The primary energy supply is by means of a centralized storage tank, while the drinking water is heated on demand in the fresh hot water module in accordance with the continuous flow principle. In the case of combination stations, the heating surfaces in living areas are connected with the underfloor heating manifolds of the heating module or the radiator connections. The heating flow temperature in the living area is regulated on a fixed-value or weather-controlled basis. Adjusting pieces are provided in the modules for on-site installation of heat meters and cold water meters. BUILDING CATEGORIES Apartment blocks Hotels and residential homes

2 TACOTHERM DUAL PIKO OVERVIEW OF VARIANTS KEY Available for this type Selectable components (either / or) Not available for this type TacoTherm Dual Piko Version of fresh hot water module PF control Connect Pages in datasheet 7 Variant A B C D A B C D FRESH HOT WATER MODULE HEATING MODULE Heat exchanger Control type Connections Installation options Regulation Underfloor heating circuit manifold Distributor accessories Primary pipe system Standard heat source Suitable for Operation with heat pumps Copper-soldered Materials Nickel-soldered Stainless steel solder Proportional flow Type Electronic regulator Static (TacoSetter Inline) Balancing Dynamic Mixer Secondary Circulation Comfort Keeping warm Bottom Top Heating / Radiator Left Right Sanitary distributor Bottom Base plate Flush-mounted frame with door Installation methods Flush-mounted frame without door Surface-mounted cabinet with door Surface-mounted cabinet without door Spagnolet lock Door accessories (optional) Locking cylinder Fixed value Type Weather-controlled Dynamic Balancing Static - Number of heating circuits - Manual adjustment Distributor valve with TacoDrive actuator Connector module for Actuators NovaMaster -pipe See next page for explanation -pipe 4-pipe NOTE REQUIREMENTS FOR FLOW MEDIA The stations heat interface units use a copper-soldered stainless steel plate heat exchanger as standard. It must be checked prior to use in the framework of system planning whether the issues of corrosion protection and scale formation have been sufficiently taken into account in accordance with DIN 988 and current drinking water analyses according to DIN EN 85. See datasheet Plate Heat Exchanger Requirements - Limit Values for Drinking Water Quality.

3 TACOTHERM DUAL PIKO PROPORTIONAL FLOW CONTROL SPECIFICATION TEXT See GENERAL TECHNICAL DATA Max. operating pressure P O max : Primary: bar Secondary: bar Overall dimensions of combination station: W 874 mm H - mm D mm Weight of combination station (empty): 7 kg Materials Galvanized or varnished sheet steel housing according to model Pipes: DN stainless steel.44 Pumps: cast iron Valve housing: brass Seals: AFM4 (flat sealing) Performance data See design diagram Electrical connection data Mains voltage: VAC ± % Mains frequency:... Hz Power consumption: max. 4 - W Protection type: IP EEI. Flow media Heating water (VDI ; SWKI BT -; ÖNORM H 595 ) Cold water as per DIN 988- and DIN EN 8-5 TECHNICAL DATA FRESH HOT WATER MODULE Max. operating temperature T O max : 95 C Weight (empty): kg Dimensions: W 874 mm H mm D mm Material Plate heat exchanger (plates and connector pieces): Stainless steel.4 Copper-soldered / nickel-soldered / stainless steel-soldered TECHNICAL DATA HEATING MODULE Max. operating temperature T O max : 7 C Weight (empty): kg Dimensions: W 874 mm H mm D mm High-efficiency circulating pump: Laing Ecofloor -/ ( V) underfloor heating circuit -way mixing valve (fixed value- controlled) or PICV valve with actuator (weather-controlled) TYPE OVERVIEW TacoTherm Dual Piko Combination station with heating circuits * ) Order no. DN Rp Dispensing range * ) Heat exchanger 7..9 " OT up to l/min copper-soldered TacoTherm Fresh Piko Fresh hot water station Order no. DN Rp Dispensing range * ) Heat exchanger 7.. " OT up to l/min copper-soldered * ) Any matching accessories required and variants can be individually selected * ) Performance data for primary = flow 7 C / secondary = hot water C; p

4 TACOTHERM DUAL PIKO PROPORTIONAL FLOW CONTROL DIMENSIONAL DRAWING Primary connection for heat supply on return side Primary connection for heat supply on supply side Connection for hot water distribution 4 Connection for cold water distribution 5 Connection for main supply line for cold water Radiator connection in supply and return circuit

5 TACOTHERM DUAL PIKO PROPORTIONAL FLOW CONTROL FLOW DIAGRAM Heating control: Fixed value Static hydronic balancing Heating control: Weather-controlled Dynamic hydronic balancing Fresh hot water module G F Fresh hot water module G F Heating module E D 8 H C B A I Heating module E D 8 C B A I H Key Plate heat exchanger Proportional flow controller Dirt trap with filter 4 Shut-off valve for heating 5 Shut-off valve with domestic hot water certification Heating pump 7 Fixed-value three-way mixer (NovaMix Value) 8 Thermometer - C 9 Cold water meter adjusting piece Heat meter adjusting piece Connection of optional temperature storage module Automatic air vent valve Weather-controlled regulation 4 Dynamic balancing valve with drive motor Flow sensor weather-controlled regulation Differential pressure controller Connections A Connection for main supply line for cold water B Connection for cold water distribution C Connection for hot water distribution D Primary connection for heat supply on supply side E Primary connection for heat supply on return side F Radiator connection in supply circuit G Radiator connection in return circuit H Connection for underfloor heating on supply side I Connection for underfloor heating on return side 5

6 TACOTHERM DUAL PIKO PROPORTIONAL FLOW CONTROL ckverlust Druc Druc ckverlust Druc eratur C eratur Zapftempe C Zapftempe Zapftemperatur Zapftemperatur C C Zapftemp Zapftemp peratur Zapftemp peratur C peratur C C TTD- Dual TTD- GBSH- Dual GBSH- TNG PM-Regler TNG PM-Regler A) Secondary pressure loss E) Hot water demand for Heizwasserbedarf/ / Heizwasserbedarf/ / Zapfmenge Zapfmenge Druckverlustsekundär Druckverlustsekundär TTD- Dual TTD- GBSH- Dual GBSH- TNG PM-Regler TNG PM-Regler Druckverlustsekundär deltap 9 9 deltap TTD- Dual GBSH- TNG PM-Regler Heizwasserbedarf/ Heizwasserbedarf/ Zapfmenge Zapfmenge 8 8 Druckverlustsekundär Druckverlustsekundär deltap deltap Heizwasserbedarf/ Zapfmenge Druckverlustsekundär deltap deltap deltap 7 deltap deltap 9 deltap 7 9 deltap Zapftemperatur primär delta p,, b / 7 C primär delta p,, / 5 C Zapftemperatur primär Dispensing 4 delta p volume 8,, (l/min) b / 7 C Zapftemperatur primär delta volume p, (l/min), / 5 C Zapfmenge l/min 7 B) Hot Zapfmenge delta p l/min water temperature = 7 C 8 F) Hot water temperature = 5 C 4 8 delta p 5 5 delta p delta p 7 Zapftemperatur primär delta p,, b / 7 C 5 primär delta 4 p, 8, / 5 C Zapftemperatur primär delta p 4,, 8 b / 7 C primär delta p,, / 5 C 55 5 delta p 55 delta p delta p delta p 7 7 Zapftemperatur primär delta p,, b / 7 C 5 5 primär delta p,, / 5 C delta 55 delta p 47 delta delta p 47 5 delta p delta p 5 delta p delta p delta p 5 delta p delta p delta delta p delta p delta 9 delta p delta p delta p delta p delta p 47 7 delta p delta p Zapfmenge l/min Zapfmenge 9 l/min Zapftemperatur delta primär p, delta, p,, / C / C Zapftemperatur delta primär p, delta, p,, / 55 C / 55 C Zapfmenge Dispensing 4 8 volume (l/min) Dispensing volume 4 (l/min) 8 l/min C) 55 Zapftemperatur Hot water Zapftemperatur delta primär p, = delta C, p,, / C / C G) Hot water Zapftemperatur temperature primär delta 55 C primär p, delta, p,, / 55 C / 55 C.. primär delta p,, / C primär delta p,, / 55 C Zapftemperatur delta primär p, delta, p,, / C / C Zapfmenge 9.9 l/min 4 8 primär Dispensing delta p, volume 4, (l/min) 8 / C 4 8 Dispensing volume (l/min) Zapftemperatur delta primär p, delta, p,, / C / C.. D) Hot water temperature = C primär delta p,, / C Dispensing temperature * for Dispensing temperature * for Dispensing temperature * for Return temperature for p Return temperature for p Return temperature for p * Temperature value without additional NovaMix mixing valve Zapfmenge l/min 4 8 Zapfmenge 4 l/min ckverlust Druc Druc ckverlust Pressure loss () Druc Zapftempe Zapftempe eratur eratur Zapftempe C C eratur C Dispensing temperature ( C) FLOW, TEMPERATURE AND PRESSURE LOSS DIAGRAMS Dispensing Zapftemperatur temperature Zapftemperatur C C ( C) C Dispensing Zapftemp Zapftemp temperature Zapftemp C C ( peratur C) C Dispensing volume (l/min) Heating water (l/h) Dispensing Zapftempe temperature eratur Zapftempe C eratur ( C) C Dispensing Zapftemperatur temperature Zapftemperatur C ( C) C eratur C Zapftempe Zapftempe eratur eratur Zapftempe C C Zapftemperatur Zapftemperatur C C C ngswasser Heizun ngswasser l/h l/h Heizun Heizun Heizun ngswasser ngswasser Heizun l/h ngswasser l/h l/h EXAMPLE OF INTERPRETING THE FLOW RATE AND PRESSURE LOSS DIAGRAMS Given Hot water dispensing volume: l/min Primary heating flow temperature: 7 C Available primary differential pressure at the station of Sought Hot water demand in l/h Pressure loss on secondary side Dispensing temperature Primary heating return temperature in C Secondary pressure loss in Approach In Diagram B) a hot water dispensing temperature of 47 ºC can be read for the given hot water dispensing volume of l/min at the intersection point with the differential pressure of, and the associated return temperature can be read at the intersection point with the return temperature line at. Diagram A) shows the pressure loss in the system on the secondary side and Diagram E) shows a hot water demand of l/h at the intersection point between the dispensing volume and the differential pressure.

7 TACOTHERM DUAL PIKO CONNECT SPECIFICATION TEXT See GENERAL TECHNICAL DATA Max. operating pressure P O max : Primary: bar Secondary: bar Overall dimensions of combination station: W 874 mm H - mm D mm Weight of combination station (empty): 7 kg Materials Galvanized or varnished sheet steel housing according to model Pipes: DN stainless steel.44 Primary pump fresh hot water module: PPS Pump heating module: cast iron Valve housing: brass Seals: AFM4 (flat sealing) Performance data See design diagram Electrical connection data Mains voltage: VAC ± % Mains frequency:... Hz Power consumption fresh hot water module: max. W Power consumption combination station incl. actuators: W Protection type: IP EEI. Flow media Heating water (VDI ; SWKI BT -; ÖNORM H 595 ) Cold water as per DIN 988- and DIN EN 8-5 TECHNICAL DATA FRESH HOT WATER MODULE Max. operating temperature T O max : 9 C Weight (empty): kg Dimensions: W 874 mm H mm D mm Primary pump: Grundfos Alpha FWM incl. Wireless Connect Materials Plate heat exchanger (plates and connector pieces): Stainless steel.4 Copper-soldered / nickel-soldered / stainless steel-soldered TECHNICAL DATA HEATING MODULE Max. operating temperature T O max : 7 C Weight (empty): kg Dimensions: W 874 mm H mm D mm High-efficiency circulating pump: Grundfos UPM Hybrid ( V) underfloor heating manifold -way mixing valve (fixed value- controlled) or PICV valve with actuator (weather-controlled) TYPE OVERVIEW TacoTherm Dual Piko Connect Combination station with heating circuits * ) Order no. DN Rp Dispensing range * ) Heat exchanger 7..9 " OT up to l/min copper-soldered TacoTherm Fresh Piko Connect Fresh hot water station Order no. DN Rp Dispensing range * ) Heat exchanger 7.. " OT up to l/min copper-soldered * ) Any matching accessories required and variants can be individually selected * ) Performance data for primary = flow C / secondary = hot water C 7

8 TACOTHERM DUAL PIKO CONNECT DIMENSIONAL DRAWING Primary connection for heat supply on return side Primary connection for heat supply on supply side Connection for hot water distribution 4 Connection for cold water distribution 5 Connection for main supply line for cold water Radiator connection in supply and return circuit

9 TACOTHERM DUAL PIKO CONNECT FLOW DIAGRAM Heating control: Fixed value Static hydronic balancing Heating control: Weather-controlled Dynamic hydronic balancing Fresh hot water module 8 G F 7 9 G F Fresh hot water module I I Heating module E D C B A H Heating module E D C B A H Key Plate heat exchanger Primary pump for fresh hot water Dirt trap with filter 4 Shut-off valve for heating 5 Shut-off valve with domestic hot water certification Optional temperature maintaining module 7 Cold water meter adjusting piece 8 Heat meter adjusting piece 9 Pressure/temperature sensor Vortex Flow Sensor Grundfos controller Drive with stepper motor Flow sensor weather-controlled regulation 4 Dynamic balancing valve with drive motor Weather-controlled regulation Optional circulation pump 7 Automatic air vent valve 8 Fixed-value three-way mixer (NovaMix Value) 9 High-efficiency pump UPM Thermometer - C Connections A Connection for main supply line for cold water B Connection for cold water distribution C Connection for hot water distribution D Primary connection for heat supply on supply side E Primary connection for heat supply on return side F Radiator connection in supply circuit G Radiator connection in return circuit H Connection for underfloor heating on supply side I Connection for underfloor heating on return side 9

10 TACOTHERM DUAL PIKO CONNECT FLOW AND PRESSURE LOSS DIAGRAMS COLD WATER HEATING BY K (... C) D) Secondary pressure loss Pressure loss () 4 5 Dispensing volume (l/min) A) Primary flow temperatures B) Primary pressure loss Hot water demand (l/h) Return temperature ( C) C 55 C C 8 5 C 9 Output Dispensing volume (l/min) C) Return temperatures on primary side C 55 C.5 C 9 5 C Dispensing volume (l/min) Outpput (kw) Hot water demand (l/h) 8 8 ( p) Pressure loss () EXAMPLE OF INTERPRETING THE FLOW RATE AND PRESSURE LOSS DIAGRAMS Given Hot water dispensing volume: l/min Primary heating flow temperature: 55 C Sought Hot water demand in l/h Primary pressure loss in Primary heating return temperature in C Secondary pressure loss in Approach In Diagram A) the hot water volume for the given hot water dispensing volume and the available primary flow temperature is,8 l/min at the point of intersection; in Diagram B) the primary pressure loss for the station is. The pump delivery head of the FWM pump is for this volume of hot water. The required primary pressure p at the station is. In Diagram C) the primary return temperature for the given dispensing volume and the selected flow temperature of C is then.5 C. In Diagram D) the secondary pressure loss for the given data is

11 TACOTHERM DUAL PIKO CONNECT FLOW AND PRESSURE LOSS DIAGRAMS COLD WATER HEATING BY K ( C) D) Secondary pressure loss 4 Pressure loss () 5 5 Dispensing volume (l/min) C) Return temperatures on primary side Hot water demand (l/h) C 5 C 7 C 8 Output Dispensing volume (l/min) Outpput (kw) B) Primary pressure loss Hot water demand (l/h) Pressure loss () A) Primary flow temperatures Return temperature ( C) C C 7 C 5 Dispensing volume (l/min)

12 TACOSYS PIKO FIXED VALUE-CONTROLLED HEATING MODULE SPECIFICATION TEXT See TECHNICAL DATA Max. operating pressure P O max : bar Max. operating temperature T O max : 7 C Dimensions: W 874 mm H mm D mm Weight (empty): kg Materials Galvanized or varnished sheet steel housing according to model Pipes: DN stainless steel.44 Pumps: cast iron Valve housing: brass Seals: AFM4 (flat sealing) Performance data See design diagram Electrical connection data Mains voltage: VAC ± % Mains frequency:... Hz Power consumption: max. 4 W Protection type: IP EEI. Flow media Heating water (VDI ; SWKI BT -; ÖNORM H 595 ) Cold water as per DIN 988- and DIN EN 8-5 Fittings dependent on model High-efficiency circulating pump: Laing Ecofloor -/ ( V) or Grundfos UPM -7 Hybrid -way mixing valve with fixed-value control Underfloor heating circuit manifold TacoSys - heating circuits Electro-thermal actuators NovaMaster connector module Electronic controller with display PICV valve TYPE OVERVIEW TacoSys Piko Heating module with heating circuits Order no. DN Rp Heating circuit connections Measuring range Supply TopMeter 7..9 " OT ¾" OT 5 l/min DIMENSIONAL DRAWING FLOW AND PRESSURE LOSS DIAGRAMS For heating module with mixing station and fixed-value control and with open TopMeters and valves Pump characteristic: Proportional flow-controlled Pressure loss () I -5 9 II III Hot water flow rate (l/h) Heating circuits 4 Heating circuits Heating circuits 4 8 Heating circuits 5 Heating circuits Laing Ecofloor Pump characteristic Pump characteristic Pump characteristic 4 Pump characteristic 4 5 Pump characteristic 5 Pump characteristic 7 Pump characteristic 7 Grundfos UPM I Pump characteristic II Pump characteristic III Pump characteristic

13 TACOSYS PIKO WEATHER-CONTROLLED HEATING MODULE SPECIFICATION TEXT See TECHNICAL DATA Max. operating pressure P O max : bar Max. operating temperature T O max : 7 C Dimensions: W 874 mm H mm D mm Weight (empty): kg Materials Galvanized or varnished sheet steel housing according to model Pipes: DN stainless steel.44 Pumps: cast iron Valve housing: brass Seals: AFM4 (flat sealing) Performance data See design diagram Electrical connection data Mains voltage: VAC ± % Mains frequency:... Hz Power consumption: max. 4 - W Protection type: IP EEI. Flow media Heating water (VDI ; SWKI BT -; ÖNORM H 595 ) Cold water as per DIN 988- and DIN EN 8-5 Fittings dependent on model High-efficiency circulating pump: Laing Ecofloor -/ ( V) or Grundfos UPM -7 Hybrid -way mixing valve with fixed-value control Underfloor heating circuit manifold TacoSys - heating circuits Electro-thermal actuators NovaMaster connector module Electronic controller with display PICV valve TYPE OVERVIEW TacoSys Piko Heating module with heating circuits Order no. DN Rp Heating circuit connections Measuring range Supply TopMeter 7..9 " OT ¾" OT 5 l/min DIMENSIONAL DRAWING FLOW AND PRESSURE LOSS DIAGRAMS For heating module with mixing station and fixed-value control and with open TopMeters and valves Pump characteristic: Constantly-controlled Pressure loss () - 9 I II III Hot water flow rate (l/h) Heating circuits 4 Heating circuits Heating circuits 4 8 Heating circuits 5 Heating circuits Heating circuits Laing Ecofloor Pump characteristic Pump characteristic Pump characteristic 4 Pump characteristic 4 5 Pump characteristic 5 Pump characteristic 7 Pump characteristic 7 Grundfos UPM I Pump characteristic II Pump characteristic III Pump characteristic

14 TACOSYS PIKO -PIPE SYSTEM HEATING MODULE SPECIFICATION TEXT See TECHNICAL DATA Max. operating pressure P O max : bar Max. operating temperature T O max : 7 C Dimensions: W 874 mm H mm D mm Weight (empty): approx. kg Materials Galvanized or varnished sheet steel housing according to model Pipes: DN stainless steel.44 Pumps: cast iron Valve housing: brass seals: AFM4 (flat sealing) Performance data See design diagram Electrical connection data Actuator Protection type: IP Electrical protection class II Rated voltage (AC or DC): 4 V or V Permitted ambient temperature: ± % Operating efficiency:.8 W Inrush current: 4 V:. A for max. min V:. A for max. ms Recommended fuse:.a slowacting, as per DIN 4 Connecting cable length: m Flow media Heating water (VDI ; SWKI BT -; ÖNORM H 595 ) Cold water as per DIN 988- and DIN EN 8-5 Fittings dependent on model Underfloor heating circuit manifold TacoSys - heating circuits Electro-thermal actuators NovaMaster connector module Electronic controller with display PICV valve TYPE OVERVIEW TacoSys Piko Heating module with heating circuits (-pipe system) Order no. DN Rp Heating circuit connections Measuring range Supply TopMeter 7..9 " OT ¾" OT 5 l/min DIMENSIONAL DRAWING PRESSURE LOSS-DIAGRAMM 8.5 For TacoSys HighEnd heating circuit manifold with TopMeter Supply ( 5 l/min; k VS =.97) Pressure loss with maximum valve opening (). Flow (l/min) CONTACT AND FURTHER INFORMATION TACONOVA.COM Taconova Group AG Neunbrunnenstrasse CH-8 Zurich T F group@taconova.com Subject to modification. /7 4

TACOTHERM DUAL PIKO MODULAR AND HIGHLY FLEXIBLE HEAT INTERFACE UNITS

TACOTHERM DUAL PIKO MODULAR AND HIGHLY FLEXIBLE HEAT INTERFACE UNITS TACOTHERM DUAL PIKO MODULAR AND HIGHLY FLEXIBLE HEAT INTERFACE UNITS CUSTOMIZE YOUR INDIVIDUAL STATION The heat interface units in the TacoTherm Dual Piko range adapt perfectly to local conditions. Whether

More information

TACOTHERM FRESH PETA (C/CL)

TACOTHERM FRESH PETA (C/CL) ACOHERM FRESH PEA (C/CL) FRESH HO WAER SAION WIH HIGH-EFFICIENCY PUMPS Fresh hot water station for hygienically heating drinking water in accordance with the continuous flow principle with and without

More information

TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY

TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY TACOTHERM DUAL DECENTRALISED DOMESTIC HOT WATER TECHNOLOGY WHAT DOES TACONOVA STAND FOR? Taconova Group AG is a well-established Swiss company with over years of experience in providing intelligent building

More information

TACOTHERM FRESH PETA X (C/CL)

TACOTHERM FRESH PETA X (C/CL) ACOHERM FRESH PEA X (C/CL) FRESH HO WAER SAION WIH HIGH-EFFICIENCY PUMPS Fresh hot water station for hygienically heating drinking water in accordance with the continuous flow principle with and without

More information

Thermowatt Sistemas Técnicos. Piso radiante.

Thermowatt Sistemas Técnicos. Piso radiante. Thermowatt Sistemas Técnicos Piso radiante www.thermowatt.pt UNDERFLOOR HEATING SYSTEMS The targeted heating of individual rooms increases the comfort level, reduces energy consumption and allows economical

More information

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance HIGH EFFICIENCY CIRCULATORS Represented by Taconova Group AG CATALOGUE 218 EN easyuse greatperformance CONTENTS WELCOME...3 HEATING SYSTEMS ES2 6...4 ES2 7...6 ES2 C A 6...8 ES2 ADAPT 6...1 ES2 ADAPT 7...12

More information

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Prefabricated units / TA-COMFORT-S TA-COMFORT-S All in one design with differential pressure

More information

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application: Data Sheet Compact Mixing Shunt for Floor Heating, FHM-Cx Application: FHM-C1 Mixing shunt FHM-C/ FHM-C Mixing shunt FHM-C Mixing shunt FHM-C The Danfoss floor heating compact mixing shunts are used for

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS data sheet Danfoss prefabricated floorheatingunit Type FH-G/FH-GS//S Application The Danfoss prefabricated underfloorheating (UFH) unit for distribution of heating and domestic water is primarily designed

More information

magnetite separator New: Dirt and TACOVENT RANGE AIR, DIRT AND MAGNETITE SEPARATOR

magnetite separator New: Dirt and TACOVENT RANGE AIR, DIRT AND MAGNETITE SEPARATOR New: Dirt and magnetite separator TACOVENT RANGE AIR, DIRT AND MAGNETITE SEPARATOR AIR, GASES AND CONTAMINANTS IN HYDRONIC PLANT SYSTEMS The energy wasted as a result of trapped particles in flow systems

More information

FHM-Cx Mixing Shunts for Floor Heating

FHM-Cx Mixing Shunts for Floor Heating FHM-Cx Mixing Shunts for Floor Heating Application Mixing shunt FHM-C5/C6 (UPS pump) The Danfoss compact mixing shunts are used for regulation of flow and supply temperature in hydronic floor heating systems.

More information

FHM-Cx Mixing Shunts for Floor Heating

FHM-Cx Mixing Shunts for Floor Heating Data Sheet FHM-Cx Mixing Shunts for Floor Heating Application A self-acting proportional regulator is used to regulate the supply temperature. The regulator ensures that the desired supply temperature

More information

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Control valves / TA-COMFORT-S TA-COMFORT-S All in one design with STAP differential pressure

More information

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold Dynalux Floor Heating Manifolds Underfl oor heating circuit manifold IMI HEIMEIER / Floor Heating Control / Dynalux Dynalux Dynalux adjusts the flow rate in the individual heating circuits directly in

More information

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface

More information

Smart temperature control solutions

Smart temperature control solutions Smart temperature control solutions State-of-the-art heating and cooling solutions, expertise & know-how combined with top quality and superior customer service. 1 1 8 7 5 9 6 10 4 3 2 www.vexve.com Contents

More information

T. +44 (0) E.

T. +44 (0) E. Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution for hot

More information

Technical information for installation and operation

Technical information for installation and operation Technical information for installation and operation PR 24002.65 12-04-2016 Subject to technical modifications LogoFresh 100 & 120 fresh water station Electronically controlled GB Meibes System-Technik

More information

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB 4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units

More information

ModuSat TP. Energy. Heat Interface Units

ModuSat TP. Energy. Heat Interface Units Energy Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution

More information

HEAT INTERFACE UNITS (Sanitary Hot Water Only)

HEAT INTERFACE UNITS (Sanitary Hot Water Only) HEAT INTERFACE UNITS (Sanitary Hot Water Only) T-FAST i20 (Sanitary Hot Water Only) 20 The T-Fast i20 is an instantaneous domestic hot water production module that produces a flow rate of 20L per/min at

More information

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS INSTALLATION INSTRUCTIONS FOR CONTROL BOXES Pay attention to the total pressure loss when connecting UV4- to the control boxes for heating areas > 16 m²!

More information

ModuSat TP. Energy. Heat Interface Units

ModuSat TP. Energy. Heat Interface Units Energy Twin Plate Heat interface unit for indirect heating and instantaneous domestic hot water with electronic thermostatic control. Designed for wall-mounting. Application The is the complete solution

More information

Solar heating systems

Solar heating systems 03 energy efficiency Compact, "ALL-IN-ONE" solar system Solar panel for swimming pools Hydraulic components Drain-Unit: dual hydraulic unit with drain back system Drain-Unit: hydraulic unit with drain-back

More information

Roth fixed-value control set with high-efficiency pump

Roth fixed-value control set with high-efficiency pump Energy Systems Roth fixed-value control set with high-efficiency pump Assembly Instructions Living full of energy Contents General information Intended use 3 Benefits 3 Layout/Components 3 Installation/Electrical

More information

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE SPECIFICATIONS... 1 OVERVIEW... 2 PRECAUTIONS... 2 MOUNTING LOCATION... 2 CONNECTION TO BOILER PRIMARY PIPING:... 3 ELECTRICAL CONNECTION... 4 FLUSHING THE

More information

TS RD 7761 RD, 7761 RD

TS RD 7761 RD, 7761 RD 1/2 HERZ Calis TS RD three way valve HERZ Calis TS RD 100% three-way valve for heating and cooling Datasheet for 1 7761 RD, Issue 0716 Dimensions in mm Order number Dimension R A B C kvs dp (bar) maximum

More information

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional. Page 1 of 5 Application The Single Plate heat interface unit (HIU) for the generation of instantaneous domestic hot water and the direct supply of space heating. This HIU provides hydraulic separation

More information

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15 PAW GmbH & Co.KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions Domestic hot water module

More information

TopVent Design Handbook

TopVent Design Handbook TopVent Design Handbook Recirculation Units and Supply Air Units for Heating and Cooling High Spaces TopVent Content TopVent DHV Recirculation unit for heating high spaces TopVent NHV Recirculation unit

More information

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB Set point thermostatic regulating unit 8 series FM 65 00 CALEFFI 090/8 GB replaces dp 090/5 GB Function The thermostatic regulating unit is made to be used in radiant panel systems, in combination with

More information

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that

More information

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation OPERATING RANGE Flow rate of up to m /h Manometric head of up to m Max. operating pressure bar Min. intake pressure, bar at 9 C Water temperature range + at + C * EEI-Part, * for a ambient temperature

More information

Metering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM. Overview. Application PRODUCT DATA

Metering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM. Overview. Application PRODUCT DATA Metering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM Overview PRODUCT DATA The Honeywell Substations series consist of the following products: Metering Box (this datasheet) Heat Interface Unit,

More information

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER Yarra s Edge Apartments, Docklands Melbourne RAYPAK Mechanical Heating and Hot Water Green s General Foods, Glendenning. ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER The use of direct fired pure copper

More information

HIGH EFFICIENCY CIRCULATORS

HIGH EFFICIENCY CIRCULATORS HIGH EFFICIENCY CIRCULATORS Heating, Cooling, Solar Thermal and Domestic Hot Water SAVINGS Up to 80% less than traditional pumps TECHNOLOGY Best available technology - PM Motor ENVIRONMENT Environment

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved. Innovation + Quality Valves, controls + systems Local and district heating technology for improved energy efficiency Product range Local and district heating technology The term Local and district heating

More information

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise. Flush Individual Room Control for Floor Heating Systems To be precise. Contents Page Multibox K, Multibox RTL and Multibox K-RTL Description Construction Application 4 Temperature Setting 4 Function Article

More information

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system

More information

Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating

Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating Product code A2RXE Founded in 1975 by Jan Aalberts. The enterprise has grown to an organisational structure in which group

More information

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS OPERATING RANGE Flow rate of up to 7 m /h* Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9C Temperature range -C at 9C Max. ambient temperature +C EEI-Part Priux

More information

Balancing & Control. Frese OPTIMIZER 6-way. Pressure Independent Control Group

Balancing & Control. Frese OPTIMIZER 6-way. Pressure Independent Control Group Balancing & Control Frese OPTIMIZER 6-way Pressure Independent Control Group Balancing & Control Frese OPTIMIZER 6-way Frese Innovative solutions from Frese balance global HVAC systems accurately and efficiently.

More information

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit series cert. n ISO / GB Function The modulating temperature regulating unit with high temperature distribution

More information

Thermostatic valve bodies

Thermostatic valve bodies Thermostatic valve bodies for single pipe heating systems Thermostatic valves with radiator connection systems IMI HEIMEIER / Thermostatic heads and Radiator valves / Thermostatic valve bodies for single

More information

LK Heat Exchanger Pack 10 -n

LK Heat Exchanger Pack 10 -n LK Heat Exchanger ack 10 -n 6 9 14 2 5 15 7 4 12 11 13 10 3 14 1 Design The LK Heat Exchanger ack -10 is primarily designed for glycol based under floor heating systems that must be isolated from other

More information

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Multibox. Floor Heating Controller Flush individual room control for floor heating systems Multibox Floor Heating Controller Flush individual room control for floor heating systems IMI HEIMEIER / Floor Heating Control / Multibox Multibox K, RTL and K-RTL Multibox K, RTL and K-RTL is used for

More information

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system New TERMOVAR Loading Unit The link between bio-energy boiler and storage tank system New TERMOVAR Loading Unit The link between bio-energy boiler and storage tank system TERMOVAR LOADING UNIT is a pre-fabricated,

More information

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17 VIESMANN VITOCELL 300-V Vertical DHW cylinder 130to500litrecapacity Datasheet Part numbers and prices: see pricelist File in: Vitotec folder, register 17 VITOCELL 300-V Type EVA and EVI Vertical DHW cylinder

More information

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility Regulux Return Lockshield Radiator lockshield with consistent presetting and drain-off facility IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regulux Regulux The Regulux is used in warm water pump

More information

Trade Product List 2013 BIOMASS ACCESSORIES

Trade Product List 2013 BIOMASS ACCESSORIES Trade Product List 2013 BIOMASS ACCESSORIES BIOMASS SYSTEM COMPONENTS Constant Temperature Control Accessories CONSTANT TEMPERATURE CONTROL PRODUCTS Order Code Description of Package and Contents Pictures

More information

Installation instructions

Installation instructions 2Power storage tank Installation instructions This installation construction contains important advice for handling, installing and starting up a 2Power solar plant. Read these advice carefully before

More information

WOLF GAS CONDENSING BOILERS COMFORTLINE

WOLF GAS CONDENSING BOILERS COMFORTLINE WOLF GAS CONDENSING BOILERS COMFORTLINE CGB-35/50 / CGB-75/100 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build

More information

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT DOC1066 GB STOKVIS ENERGY SYSTEMS 96R WALTON ROAD EAST MOLESEY SURREY KT8 0DL TEL: 08707 707 747 FAX: 08707 707 767 E-MAIL:info@stokvisboilers.com

More information

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge Regulux Description Separate presetting cone for consistent

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

TECHNICAL DATA SHEET Member of Uponor Group

TECHNICAL DATA SHEET Member of Uponor Group THNIAL ATA SHT Member of Uponor roup Home station WS-1000 WS-1000-10 WS-1000-14 WS-1000-20 WS-1000-30 WS-1000-40 asic unit Hydraulic diagram 25 2 24 3 7 10 omestic. TWW hot Wohnung water home. TW vom Strang

More information

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 0 l capacity Datasheet Part no. and prices: see pricelist VITOCELL 300-V Type EVA and EVI Vertical DHW cylinder made from stainless steel 5/2012 Product

More information

RAYPAK HOT WATER & HEATING

RAYPAK HOT WATER & HEATING All copper & bronze construction On/Off & modulating models High temperature applications RAYPAK HOT WATER & HEATING Raypak is a compact, efficient heating design which is the ideal way to heat large quantities

More information

RAYPAK HOT WATER & HEATING

RAYPAK HOT WATER & HEATING All copper & bronze construction On/Off & modulating models High temperature applications RAYPAK HOT WATER & HEATING Raypak is a compact, efficient heating design which is the ideal way to heat large quantities

More information

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off Multibox 4 Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off IMI HEIMEIER / Floor Heating Control / Multibox 4 Multibox 4 RTL and K-RTL and K-RTL is

More information

Systems for central heating

Systems for central heating www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering

More information

T. +44 (0) E.

T. +44 (0) E. ModuSat Single Plate-Double Circuit (SPDC) Heating Interface Units The Evinox ModuSat satellite heating system has been designed to provide apartments and communal housing developments with independent

More information

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems.

1 valve needed instead of 3 for pressure, flow and zone control of water-based heating systems. AB-PM Consistent hydronic control Continuous energy savings AB-PM automatic balancing valve for a reliable and energy-saving heating system. 1 valve needed instead of 3 for pressure, flow and zone control

More information

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function Thermostatic regulating unit for heating systems 66 series ACCREDITED ISO 9 FM 6 8/7 GB replaces dp 8/ GB Function The thermostatic regulating unit performs the function of keeping the flow temperature

More information

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET Circulator pumps 50/60 Hz 2 Product range 2. Product range UP(S) COMFORT, 50/60 Hz Pump type 24-hour timer Supplied with Dimensions Accessories Data sheet Thermostat Isolating valve

More information

WOLF VENTILATION SYSTEM PRICE LIST

WOLF VENTILATION SYSTEM PRICE LIST VENTILATION SYSTEM PRICE LIST JANUARY 2018 30m 3 /h THE EXTENSIVE EQUIPMENT RANGE from system supplier WOLF offers the ideal solution for commercial and industrial buildings, new build and modernisation

More information

Flush individual room control for floor heating systems

Flush individual room control for floor heating systems Multibox Flush individual room control for floor heating systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGiNEERiNG ADVANTAGE Multibox is used for decentralized control

More information

7002K. art.7002k/2. art.7002k/1 DESCRIPTION. Complete mixing kit with circulation pump (ErP Ready 641/2009/EC - 622/2012/EC), thermostatic valve with

7002K. art.7002k/2. art.7002k/1 DESCRIPTION. Complete mixing kit with circulation pump (ErP Ready 641/2009/EC - 622/2012/EC), thermostatic valve with TCHNICAL SPCIFICATION 7002K/1 & 7002K/2 DSCRIPTION 7002K Complete mixing kit with circulation pump (rp Ready 641/2009/C - 622/2012/C), thermostatic valve with remote sensor, non-return valve and balancing

More information

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Catalog. Self-operated Regulators Volume 2 Temperature Regulators Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure

More information

TACOTHERM FRESH PETA / PETA X

TACOTHERM FRESH PETA / PETA X TACOTHERM FRESH PETA / PETA X FRESH WATER STATION V01.2017 01/2017 Item no. 212515 EA no. 1226 OPERATING INSTRUCTIONS CONTACT AND ADDITIONAL INFORMATION WWW.TACONOVA.COM Taconova Group AG 2016 Neubrunnenstrasse

More information

RA 2000 Series RA 15/6T & TB Conversion Valve

RA 2000 Series RA 15/6T & TB Conversion Valve RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water

More information

MIX2 - MIX3 MIX2 MIX3 COMPONENTS DESCRIPTION DIMENSIONS

MIX2 - MIX3 MIX2 MIX3 COMPONENTS DESCRIPTION DIMENSIONS TCHNICAL SPCIFICATION DSCRIPTION Thermostatic mixing kit with micrometric valve with thermostatic option, circulation pump (rp Ready 641/2009/C - 622/2012/C), balancing lockshield and couple of manifolds

More information

Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy

Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy Contact person RISE Daniel Månsson 2018-08-07 8P04823 1 (13) Energy and circular economy +46 10 516 53 28 daniel.mansson@ri.se Flamco LTD Washway Lane, St. Helens Merseyside WA10 6PB Great Britain Testing

More information

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing Water Heater Supplement STOKVIS ENERGY SYSTEMS 96R Walton Road East Molesey Surrey KT8 0DL Tel: 020 8783 3050 / 0870 7707747 Fax: 020

More information

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1 HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1 INSTALLATION, COMMISSIONING AND OPERATING INSTRUCTIONS Contents Unit as delivered

More information

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation Standard C Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard C Standard C The Standard C thermostatic

More information

Technical Data Manual

Technical Data Manual VITOTRONIC 300 Weather-responsive indoor/outdoor, digital boiler control for heating systems with one or more heating circuits Technical Data Manual Vitotronic 300 Model KW3, Part No. Z001 231 For operation

More information

ULTRAFLOW 54 DN

ULTRAFLOW 54 DN Data sheet ULTRAFLOW 54 DN150-300 For flow from 150 m³/h up to 1000 m³/h Ultrasonic flow sensor Compact design Static meter, no moving parts Large dynamic range No wear High accuracy Longevity MID-2004/22/EC

More information

High-efficiency circulating pumps Heating Air conditioning 50 Hz

High-efficiency circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE Flow rate of up to m /h Manometric head of up to 8 mwc Max. operating pressure bar Min. suction pressure, bar at 9 C Temperature range - C at 9 C Max. ambient temperature + C EEI-Part,

More information

ThermoDual Domestic hot water charging system

ThermoDual Domestic hot water charging system ThermoDual Domestic hot water charging system Description/Application ThermoDual is the compact and effective domestic hot water (DHW) charging system. Due to the consistent use of carefully selected components

More information

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan Installation plan Washing machine PW 5064 MOPSTAR 60 To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation and commissioning

More information

Components for solar heating systems

Components for solar heating systems solarorkli Components for solar heating systems Components for heating and plumbing Components for solar heating systems Manifolds and distribution equipment Thermostatic valves Manual valves Motorised

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan Installation plan Washing machine PW 6055 AV/LP PW 6065 AV/LP To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation

More information

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems E-Z Valve Thermostatic valves with radiator connection systems For single and two-pipe heating systems IMI HEIMEIER / Thermostatic heads and Radiator valves / E-Z Valve E-Z Valve E-Z Valve with immersion

More information

heat interface units A BOILER WITHOUT A FLAME

heat interface units A BOILER WITHOUT A FLAME A BOILER WITHOUT A FLAME heat interface units Communal Heat Networks A central boiler house will generate heat which is distributed through a network of pipe to each home or apartment in the building.

More information

Say heating. Say Herz. HERZ-Supply Engineering

Say heating. Say Herz. HERZ-Supply Engineering HERZ-Supply Engineering Medium Temperature Control Pressure Control Fittings Control Fittings Lock Shields and Isolators Accessories Spare Parts Say heating. Say Herz. HERZ Valves UK Progress House [ Moorfield

More information

GRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION

GRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION GRUNDFOS ALLDOS DISINFECTION ALLDOS DISINFECTION SYSTEMS with Chlorine Gas 1 GRUNDFOS ALLDOS DISINFECTION Content Applications 4-5 Page Geco 103-100 compact dosing unit 1 Vacuum regulator and dosing unit

More information

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET UPS2 Circulator pumps 50/60 Hz UPS2 Table of contents 1. Product introduction 3 Type key.................................................................................... 3 Performance

More information

Kitchen Water Dispenser

Kitchen Water Dispenser HOT & COLD WATER DISPENSER Article number: 17861875 Max. flow 2 l/min at 3 bar flow ready-to-use control unit for wall mounting (135 mm x 160 mm x 60 mm) electronic magnetic valve 100-230 V, 50-60 Hz,

More information

HERZ Differential Pressure Control Valve 4002

HERZ Differential Pressure Control Valve 4002 HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002

More information

Contact person Date Reference Page Daniel Månsson P07886B-rev2 1 (14) Energy and bioeconomy

Contact person Date Reference Page Daniel Månsson P07886B-rev2 1 (14) Energy and bioeconomy Contact person Daniel Månsson 2016-04-15 5P07886B-rev2 1 (14) Energy and bioeconomy +46 10 516 53 28 Daniel.Mansson@sp.se FairHeat Ltd, 10 Stoney Street, London SE1 9AD16 United Kingdom Testing of heat

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,

More information

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min Heat on Air heaters from 400 Watt to 17 400 Watt Blowers from 1,45 m 3 /min to 16,5 m 3 /min BAK Thermoplastic Need-to-know Calculation of air heaters 1. Heat requirement calculation Formula: Q = m * c

More information

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY Hot Water Energy Storage HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY THE HOT WATER PEOPLE Hot Water Energy Storage THE HOT WATER PEOPLE Providing premium hot

More information

WZS 82(H)(K)3M 20 I B0W I I I (263) (288) 7.0

WZS 82(H)(K)3M 20 I B0W I I I (263) (288) 7.0 WZS 4(H)(K)M WZS 6(H)(K)M WZS 8(H)(K)M WZS (H)(K)M WZS 1(H)(K)M 0 I 60-5 5 B0W65 1 4 I I I -1 50 (58) 178 58 65 50 60 0 I 60-5 5 B0W65 1 4 I I I -1 55 (6) 178 58 65 50 60 0 I 60-5 5 B0W65 1 4 I I I -1

More information

Data sheet: Wilo-RainSystem AF Comfort MC 304

Data sheet: Wilo-RainSystem AF Comfort MC 304 Data sheet: Wilo-RainSystem AF Comfort MC 304 Pump curves Wilo-RainSystem AF Comfort H/m 50 Wilo-RainSystem AF Comfort Approved fluids (other fluids on request) Pure water without settling sediment Rainwater

More information

Circulation pumps. Wet rotor circulators and accessories. Heating Potable water Solar Geothermy Condensate

Circulation pumps. Wet rotor circulators and accessories. Heating Potable water Solar Geothermy Condensate Circulation pumps Wet rotor circulators and accessories eating Potable water Solar Geothermy Condensate CATALOGUE / alm produces highly-efficient heating circulation pumps alm has been successfully developing

More information