1 2017 NFPA Conference & Expo Effective Messaging on School Door Locking Ron Coté, P.E. NFPA At the conclusion of this program participants will be able to: 1. Understand the conflicting needs of security versus safety relative to classroom door locking 2. Recognize safe door locking procedures and the hardware for accomplishing such safety 3. Recognize hardware and procedures that fail to provide occupant safety in the guise of security 4. Tailor effective messaging to achieve safe classroom door locking 2 1
2 Sandy Hook (2012) Oikos Univ. (2012) Virginia Tech (2007) Red Lake HS (2005) Columbine (1999) The safest place to be is behind a locked classroom door 2
3 door jammers Chapter 14 New Educational Occupancies Chapter 15 Existing Educational Occupancies * [ *] Classroom Door Locking to Prevent Unwanted Entry 3
4 * [ *] Classroom Door Locking to Prevent Unwanted Entry * [ *] Classroom Door Locking to Prevent Unwanted Entry * advisory annex 4
5 A [A ] While [ ] establishes locking criteria for classroom doors only, a school s emergency action plan could identify situations where other areas need to be secured. The provisions of this subsection should be considered when evaluating those areas as well. Examples of such areas are administrative offices, gymnasiums, teacher lounges, libraries, auditoriums, and cafeterias * [ *] Classroom Door Locking to Prevent Unwanted Entry Classroom doors shall be permitted to be locked to prevent unwanted entry provided that the locking means is approved and all of the following conditions are met: 5
6 1of 10. The locking means shall be capable of being engaged without opening the door 2 of 10. The unlocking and unlatching from the classroom side of the door can be accomplished without the use of a key, tool, or special knowledge or effort 6
7 3 of 10. The releasing mechanism shall open the door leaf with not more than: one releasing operation [Chapter 14 for new] two releasing operations [Chapter 15 for existing] 4 of 10. The releasing mechanism for unlocking and unlatching shall be located at a height not less than 34 in. and not more than 48 in. above the finished floor 7
8 5 of 10. Locks, if remotely engaged, shall be unlockable from the classroom side of the door without the use of a key, tool, or special knowledge or effort 6 of 10. The door shall be capable of being unlocked and opened from outside the room with the necessary key or other credential 8
9 7 of 10. The locking means shall not modify the door closer, panic hardware, or fire exit hardware 8 of 10. Modifications to fire door assemblies, including door hardware, shall be in accordance with NFPA 80 9
10 9 of 10. The emergency action plan, required by [15.7.1], shall address the use of the locking and unlocking means from within and outside the room 10 of 10. Staff shall be drilled in the engagement and release of the locking means, from within and outside the room, as part of the required emergency egress drills 10
11 Traditional classroom lockset Security classroom lockset Entrance/office lockset Storeroom lockset Electronic access control lockset PRO Turning key in outside lever locks or unlocks the outside lever Only authorized personnel can lock Free egress CON Classroom occupant must open door in order to lock the outside lever Keys must be issued Process must be in place to ensure locks are locked when needed 11
12 PRO Outside lever can be locked by key from inside the room Indicator identifies door is locked/unlocked Only authorized personnel can lock Inside cylinder provides free egress CON Keys must be issued Process must be in place to ensure locks are locked when needed PRO Depressing button or rotating turn piece locks outside lever Outside lever locked from inside the room Indicator identifies door is locked/unlocked Inside cylinder provides free egress CON Door can be locked by anyone, including the intruder Process must be in place to ensure locks are locked when needed 12
13 PRO Outside lever is always locked, cannot be unlocked Free egress CON Door is always locked when closed, so might be inconvenient for classroom access once class has begun PRO Locking/unlocking controlled electrically Doors can be locked from central command station Door cannot be locked by unauthorized person Free egress CON High $$ cost 13
14 The classroom door must be capable of being unlocked and opened from outside the room with the necessary key or other credential 14
15 2017 NFPA Conference & Expo CEUs: To receive CEUs for this session, scan your badge at the back of the room before leaving Evaluation: Complete a session evaluation on the mobile app. (Search app store for NFPA 2017 C&E. ) Handouts: Handouts will be available via the mobile app and at nfpa.org/conference Recordings: Audio recordings of all sessions will be available free of charge via NFPA Xchange. 15
Health Care Facility Rehabilitation
2017 NFPA Conference & Expo Health Care Facility Rehabilitation Effective Application of NFPA 101 2012, Life Safety Code Chapter 43 Building Rehabilitation Ron Coté, P.E. NFPA Health Care Facility Rehabilitation
More information9/23/ :20 AM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification
of 4 9/23/2016 10:20 AM Second Revision No. 6501-NFPA 5000-2016 [ Section No. 17.2.2.2.4 ] 17.2.2.2.4* Classroom Door Locking to Prevent Unwanted Entry. Classroom doors shall be permitted to be locked
More information9/20/2016 2:53 PM. Second Revision No NFPA [ Section No ] Supplemental Information. Submitter Information Verification
Second Revision No. 2011-NFPA 101-2016 [ Section No. 14.2.2.2.4 ] 14.2.2.2.4* Classroom Door Locking to Prevent Unwanted Entry. Classroom doors shall be permitted to be locked to prevent unwanted entry
More informationDelayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.
9/20/2016 2:27 PM Second Revision No. 5006-NFPA 101-2016 [ Section No. 3.3.56 ] 3.3.56 Delayed Action Closer. Self-closing device that incorporates a delay prior to the initiation of closing. Mechanical
More informationChanges to NFPA 101A 2013 Edition for Health Care Facilities
2017 NFPA Conference & Expo Changes to NFPA 101A 2013 Edition for Health Care Facilities Presented by: William Koffel, P.E, FSFPE Lennon Peake, P.E. Koffel Associates Koffel Associates President Manager
More informationHands On Training for Fire Door Products and Fire Door Assemblies
2017 NFPA Conference & Expo Hands On Training for Fire Door Products and Fire Door Assemblies Presented by: Paul M. Goldense, FDAI Goldense Building Products, Inc. Jeffery S. Batick, FDAI Allegion Why
More informationSchool Security A Look at Classroom Door Locking Solutions Frank Rocky Rivas, AHC, FDAI, CSI, CDT, CAT, ASSOC. AIA.
Provider Name: Best Access Solutions, Inc. Provider Number: J109 SCHSEC15 Hours: 1.0 Hours HSW: Yes School Security A Look at Classroom Door Locking Solutions Frank Rocky Rivas, AHC, FDAI, CSI, CDT, CAT,
More informationLarge Airports Maintaining Fire Safety through the years
2017 NFPA Conference & Expo through the years Presented by: Panos Samaras Fire Safety Officer Athens International Airport Greece 1 Main Points Part 1 Identify Regulatory Environment Recent Fires in Airports
More informationThe Situation. Modeling Storage Occupancies Under Sloped Ceilings. Concerns (Elevation View) The Concerns 4/29/ NFPA Conference & Expo
2014 NFPA Conference & Expo Modeling Storage Occupancies Under Sloped Ceilings Presented by: Kenneth E. Isman NFSA Victoria B. Valentine NFSA Andre Marshal CSS NFPA 13 defines a sloped ceiling as one where
More informationDust Hazard Assessments
2017 NFPA Conference & Expo Dust Hazard Assessments The Importance of DHAs in Establishing Work Practices and Facilities Presented by: Jason Reason, CIH, CSP, CHMM Lewellyn Technology, LLC Learning Objectives
More informationFirst Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement
of 43 10/20/2015 4:02 PM First Revision No. 2035-NFPA 101-2015 [ Global Input ] To 14.3.4.4.1, add an item (4) to read: (4) Carbon monoxide detectors shall be installed centrally located within occupiable
More informationSecuring your school. Door hardware solutions for primary education
Securing your school Door hardware solutions for primary education Security at every layer Successful school operation combines a safe and secure environment with the freedom needed to focus on education.
More informationProtecting Special Industrial Hazards with NFPA Codes & Standards
2017 NFPA Conference & Expo Protecting Special Industrial Hazards with NFPA Codes & Standards Different Facilities & Similar Risks Presented by: Bruce H. Clarke, CFPS, UL- CRP Head of Global Property Engineering
More informationEnhancing K-12 Security
The official publication of ALOA SPAI, an international association of security professionals October 2016 SECURING YOUR SUCCESS Enhancing K-12 Security Recent code proposals may shake up safety practices
More information5/9/2017. Understanding Risk Analysis and Emergency Planning and How They Affect the Design of Emergency Communications Systems
Understanding Risk Analysis and Emergency Planning and How They Affect the Design of Emergency Communications Systems Wayne D. Moore, P.E., CFPS, CET Vice President, Corporate Strategy JENSEN HUGHES Understanding
More information2014 NFPA Conference & Expo
2014 NFPA Conference & Expo NFPA Wildland Standards Development: Where We ve Been and Where We re Going Presented by: Ryan Depew NFPA Emergency Services Spc. OVERVIEW NFPA Technical Committees NFPA Wildland
More informationArtificial Trees and Fire Performance
2017 NFPA Conference & Expo Artificial Trees and Fire Performance Presented by: Dwayne Sloan Manager, Principal Engineers Building Materials & Suppression UL LLC Learning Objectives Frame the Fire Problem
More informationProposed Changes to NFPA
2017 NFPA Conference & Expo Proposed Changes to NFPA 72-2019 Presented by: Manuelita David (SIG-FUN), Jensen Hughes Warren Olsen (SIG-SSS), Fire Safety Consultants, Inc. Merton Bunker (SIG-AAC), EYP Architecture
More informationMaintaining Building and Fire Safety During Active Assailant Events and Other Terrorist Events
Position Statement Maintaining Building and Fire Safety During Active Assailant Events and Other Terrorist Events Maintaining school safety in light of recent terrorist events is challenging for everyone,
More informationWelcome DISCLAIMER. Testing Electric Fire Pumps You Need to Understand the Arc Flash Hazard 5/1/ NFPA Conference & Expo
2017 NFPA Conference & Expo Testing Electric Fire Pumps You Need to Understand the Arc Flash Hazard Presented by: Tracey D. Bellamy, PE, CFPS Chief Engineering Officer Telgian Corporation Welcome Instructor
More informationCity of South Salt Lake Fire Code Training Exiting, Egress Systems and Egress Control
City of South Salt Lake Fire Code Training Exiting, Egress Systems and Egress Control 11-27-12 This document is designed as a summary guide using IFC requirements for the provisions associated with exiting,
More informationFire Dynamics Research Applied to. Fire Investigation. Overview
2017 NFPA Conference & Expo Fire Dynamics Research Applied to Fire Investigations Presented by: Daniel Madrzykowski Research Engineer UL Firefighter Safety Research Institute Fire Investigation What is
More informationINFORMATIONAL PUBLICATION SECURITY VS. EXITING... Door Locking Hardware in Schools
INFORMATIONAL PUBLICATION SECURITY VS. EXITING... Door Locking Hardware in Schools DSA Guidelines for Door Locking Hardware in Schools Egress doors shall be readily openable from the egress side without
More informationReport to Adhoc Health Code change proposal regarding locking arrangements From John Woestman, BMHA
Report to Adhoc Health Code change proposal regarding locking arrangements From John Woestman, BMHA This report is provided for information only. BMHA is not asking for Adhoc Health Care to sponser as
More informationDelayed Action Closer. Mechanical self-closing device that incorporates an adjustable delay prior to the initiation of closing.
Second Revision No. 5006-NFPA 101-2016 [ Section No. 3.3.56 ] 3.3.56 Delayed Action Closer. Self-closing device that incorporates a delay prior to the initiation of closing. Mechanical self-closing device
More informationDeputy Assistant Secretary Indian Affairs (Management)
Deputy Assistant Secretary (Management) Office of Facilities, Property and Safety Management Division of Safety and Risk Management Fire Drills Training Objectives Support Fire Safe Operations Guidance
More informationAbout the Instructor & Presenter:
About the Instructor & Presenter: Paul G. Baillargeon, AHC, FDAI Vice President, Technical Consulting Door Security & Safety Foundation A noted veteran in the door and hardware industry, Mr. Baillargeon
More informationDraft. Security Study. Germantown School District Germantown, WI. PRA Project # February 2014
Draft Security Study Germantown School District Germantown, WI PRA Project # 114440 February 2014 February 2014 Germantown School District Facilities Security Study Page 1 Facilities Security Study Page
More informationSafe and Secure. Introducing Responsive Lockdown
Safe and Secure Introducing Responsive Lockdown CHOOSE THE BEST RESPONSE BEST SHELTER SIMPLY SECURING SAFE SPACES A NEW RESPONSE TO SCHOOL SECURITY School security is one of the greatest responsibilities
More informationEducation. Life Safety and Security Door Hardware. Integrated Door Security Systems. Safety, Security and Risk Management
Education Life Safety and Security Door Hardware Integrated Door Security Systems Safety, Security and Risk Management Door hardware made for A+ reliability More than just for main doors, Detex hardware
More informationCodes and Standards FFP1510, BFST1510, ATCP1510
DEPARTMENT OF FINANCIAL SERVICES Division of State Fire Marshal Bureau of Fire Standards & Training Title: Master Syllabus Date: July, 2017 Codes and Standards FFP1510, BFST1510, CP1510 Course Title Codes
More informationSafe and Secure. Introducing Responsive Lockdown
Safe and Secure Introducing Responsive Lockdown CHOOSE THE BEST RESPONSE BEST SHELTER SIMPLY SECURING SAFE SPACES A NEW RESPONSE TO BUILDING SECURITY There was a time when an individual s safety in a public
More informationICC code change proposals are being reviewed, evaluated, prioritized, and desired results determined by the BHMA Task Group working on the proposals.
BHMA ICC Code Proposals John Woestman, March 23, 2015 ICC code change proposals are being reviewed, evaluated, prioritized, and desired results determined by the BHMA Task Group working on the proposals.
More informationOUR MISSION. OUR MISSION is to promote secure
OUR MISSION OUR MISSION is to promote secure and safe openings that enhance life safety through outreach efforts that include awareness and education within the building design, code authority and facility
More informationPage 1 of 5 1/29/2016 4:08 PM. First Correlating Revision No. 3-NFPA [ Section No ] Submitter Information Verification
First Correlating Revision No. 3-NFPA 101-2016 [ Section No. 6.1.8.1.1 ] 6.1.8.1.1* Definition One- and Two-Family Dwelling Unit. A building that contains not more than two dwelling units, with independent
More informationNFPA 101 Code Update from 2012 Edition to the 2015 Edition
NFPA 101 Code Update from 2012 Edition to the 2015 Edition Presented by: Gary Furdell AHCA Fire Protection Specialist 1 2 2012 Update to 2015 Chapter 18 New Health Care Occupancies 4 18.1.3.2 Atrium walls
More informationHEALTH/LIFE SAFETY ANNUAL INSPECTION CHECKLIST (ROE)
HEALTH/LIFE SAFETY ANNUAL INSPECTION CHECKLIST (ROE) Administrative and General Building Requirements Safety reference plans (1) Fire alarm audibility (10) Alcohol hand-rub-dispensers (19) School safety
More informationAPPENDIX F: LOCKSETS AND ACCESS CONTROL
APPENDIX F: LOCKSETS AND ACCESS CONTROL F.1 LOCKSETS The University, with the exception of the Housing Division which uses a Best 7-pin system, utilizes a Corbin Russwin 7-pin IC Core keying system. Locksets
More informationABLOY EFEND. New name for security
ABLOY EFEND New name for security SET SECURITY TO NEXT LEVEL ABLOY is now available in ANSI door environment. OPTIONS FOR EVERY NEED Inclusive product range includes both electric and mechanical locking
More informationRooftop Photovoltaic (PV) Systems Examining the Risks and Researching the Options
2016 NFPA Conference & Expo Rooftop Photovoltaic (PV) Systems Examining the Risks and Researching the Options Presented by: Joel Sipe Senior Managing Engineer Exponent Inc. Outline Project Background Fire
More informationThis regulation outlines procedures to be followed for fire drills and all school event decorations.
SUPPORT SERVICES September 14, 2016 SUPPORT SERVICES Fire Safety I. Purpose The purpose of this regulation is to establish guidelines for promoting fire safety awareness, practices, and policies to ensure
More informationAPPROVED: Dayroom: Space for activities that is situated immediately adjacent to the youth sleeping areas and separated from them by a wall.
GEORGIA DEPARTMENT OF JUVENILE JUSTICE Applicability: { } All DJJ Staff { } Administration { } Community Services {x} Secure Facilities (RYDCs & YDCs) Transmittal # 17-4 Chapter 7: PHYSICAL PLANT Effective
More informationSARGENT Beacon TM. A Technical and Informational Newsletter From Dugmore & Duncan. Summer 2009 Vol. VIII - Issue II L
A Technical and Informational Newsletter From Dugmore & Duncan Summer 2009 Vol. VIII - Issue II L Safe Egress You Can See, Hear & Trust SARGENT Beacon TM SARGENT introduces Beacon, a next generation exit
More informationAlternate Evacuation Route B: Secondary direction of egress considered safe with the information available.
SOG NUMBER: MC-ER-04 REVISION NO: 13 PAGE 1 OF 5 I. PURPOSE To identify and establish Emergency Action and Response plans for regulatory compliance and to provide an operational framework for emergency
More informationSAFETY DRILLS Lincoln County School District
SAFETY DRILLS Lincoln County School District Lincoln County School District understands the importance of drilling students and staff on emergency procedures in order to prepare them to respond safely
More informationTeachers. Updated / /20. Emergency Contacts 1. Evacuation 2. Lockdown 3. Exterior Lockdown 4. Clear the Halls 5. Reverse Evacuation 6
Topic Page Emergency Contacts 1 Evacuation 2 Lockdown 3 Exterior Lockdown 4 Clear the Halls 5 Reverse Evacuation 6 Off-Campus Evacuation 7 Shelter-In-Place 8 Teachers Updated / /20 5970 (4-13) EMERGENCY
More informationWhite Bear Lake Area Schools District 624 ENERGY GUIDELINES
White Bear Lake Area Schools District 624 ENERGY GUIDELINES Developed by: White Bear Lake Area Schools Energy Steering Committee as part of the Schools for Energy Efficiency (SEE) Program ISD 624 Energy
More information4/9/2015. Introductions. Introductions Scott Lord Executive Officer, All Systems. Mass Notification And Emergency Communications (MNEC)
Mass Notification And Emergency Communications (MNEC) Scott Lord, All Systems Chuck Wilson, National Systems Contractors Association 1 Chuck Wilson Executive Director, NSCA Introductions The National Systems
More informationNFPA Changes
Chapter 21, Emergency Control Functions and Interfaces Summary. Chapter 21 is new. These requirements were formerly found in Chapter 6, Protected Premises Fire Alarm Systems. The term fire safety function
More informationFire Rated Door Assemblies: Compliant Designs
Fire Rated Door Assemblies: Compliant Designs Steel Door Institute www.steeldoor.org AIA Provider #G389 Course #: SDIFIRE 1 HSW CE hour 1 Credit(s) earned on completion of this course will be reported
More informationEducational Programs for Architectural Door Openings. AIA/CES and GBCI/CMP
s for Architectural Door Openings AIA/CES and GBCI/CMP AIA/CES and GBCI/CMPC s... 3 6 Request for Continuing Education Programs.... 7 s Overview As an approved provider of AIA/CES (American Institute of
More informationLive Fire Training Instructor Program. Name: Dr. Barbara Klingensmith
DEPARTMENT OF FINANCIAL SERVICES Division of State Fire Marshal Bureau of Fire Standards & Training Title: Master Syllabus Date: October 20, 2016 Live Fire Training Instructor Program Course Title Live
More informationAGENDA. NFPA Correlating Committee on Safety to Life (SAF-AAC) NFPA 101 Second Draft Meeting. November 17, NFPA Headquarters, Quincy, MA
AGENDA NFPA Correlating Committee on Safety to Life (SAF-AAC) NFPA 101 Second Draft Meeting November 17, 2016 NFPA Headquarters, Quincy, MA 1. Call to order. Call meeting to order by Chair Bill Koffel
More informationKeys to an Effective School Lockdown
Keys to an Effective School Lockdown Door locks and hardware play an important role in a school lockdown and must be carefully considered to ensure the safety of students and faculty. The recommended safety
More informationAlternate Evacuation Route B: Secondary direction of egress considered safe with the information available.
SOG NUMBER: MC-ER-04 REVISION NO: 10 PAGE 1 OF 5 I. PURPOSE To identify and establish Emergency Action and Response plans for regulatory compliance and to provide an operational framework for emergency
More informationSP07: Coordinating New Door Assembly Installation with Access Control Systems
SP07: Coordinating New Door Assembly Installation with Access Control Systems Keith E. Pardoe, DAHC, CDC, CDT Door and Hardware Institute (DHI) Thursday, April 11, 2013 Provider #: K054 Learning Objectives
More informationEMC Company Background. Top 10 List (cont.) Top 10 List. Locked Door Policy. 1. Lack of a Security Culture
Larry Readout, CSP Senior Engineer EMC Company Background Founded in 1911 Property/casualty focus Des Moines, IA 17 branches (Wichita) 1500 school districts Security services since 1993 Top 10 List Top
More informationFirst Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement
of 47 10/21/2015 9:37 AM First Revision No. 5041-NFPA 101-2015 [ Global Input ] Throughout the document, change electrically controlled egress door assemblies to door hardware-release of electrically locked
More informationDelivering Security, Life-Safety & Convenience
A c c e s s C o n t r o l : Delivering Security, Life-Safety & Convenience An Overview of Door & Hardware Components B y T. J. G o t t w a l t, A H C / C D C, C S I, C D T Designing a building without
More informationCh. 54 GROUP B EDUCATIONAL 34 CHAPTER 54. GROUP B EDUCATIONAL OCCUPANCY GROUP
Ch. 54 GROUP B EDUCATIONAL 34 CHAPTER 54. GROUP B EDUCATIONAL OCCUPANCY GROUP Sec. 54.1. Group B occupancies. 54.2. Classification. 54.3. Nursery schools, day care centers and the like. 54.4. Separation
More informationTHE UNIVERSITY OF TEXAS AT SAN ANTONIO. Special Event Planning Considerations
Special Event Planning Considerations 2018 Contents UTSA OFFICE OF EMERGENCY MANAGEMENT... 3 OVERVIEW... 3 CONTACT INFORMATION... 3 SOCIAL MEDIA... 3 GENERAL EVACUATION PROCEDURES... 4 GUIDELINES FOR EVACUATING
More informationLIFE SAFETY CODE ESSENTIALS PRESENTED BY: LARRY VIGIL, RISK CONSULTANT
LIFE SAFETY CODE ESSENTIALS PRESENTED BY: LARRY VIGIL, RISK CONSULTANT INTRODUCTION 2007-11 5,690 Structure fires 75 Civilian Deaths $83 Million Direct Property Damage 71% in Nursery, Elementary, Middle
More informationFIRE SAFETY POLICY. 2.0 Under national, provincial and municipal fire regulations, the Board will ensure compliance with:
FIRE SAFETY POLICY 1.0 The Halifax Regional School Board recognizes the need for a planned program of fire safety to ensure a safe environment for all personnel and pupils. 2.0 Under national, provincial
More informationSafety & Security Checklist by Layers of Building and Grounds The Church Safety and Security Guidebook (Brotherhood Mutual Insurance)
Appendix D Safety & Security Checklist by Layers of Building and Grounds The Church Safety and Security Guidebook (Brotherhood Mutual Insurance) Assessing Specific Areas Look at each Layer of Security
More informationMINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY
MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division 444 Cedar Street, Suite 145, St. Paul, Minnesota 55101-5145 Phone: 651/201-7200 FAX: 651/215-0525 TTY: 651/282/6555 Internet: http://www.fire.state.mn.us
More informationProposed Changes to NFPA
2017 NFPA Conference & Expo Proposed Changes to NFPA 72-2019 Presented by: Daniel O Connor (SIG-IDS), Jensen Hughes Robert Schifiliti (SIG-NAS), R.P. Schifiliti Associates William Koffel (SIG-ECS), Koffel
More informationNFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES
NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES Sharon S. Gilyeat, P.E., Principal Koffel Associates, Inc. www.koffel.com sgilyeat@koffel.com Expertly Engineering Safety From Fire
More informationRichard B. Alpert, P.E. Senior FPE, Clark Nexsen
Richard B. Alpert, P.E. Senior FPE, Clark Nexsen Clark Nexsen is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of
More informationPuyallup School District Emergency Response Procedures Supported by Communities In Schools of Puyallup
Puyallup School District Emergency Response Procedures Supported by Communities In Schools of Puyallup Approved November 17, 2016 Table of Contents: Page 2: Fire Evacuation Procedure Page 4: Earthquake
More informationSMARTair SOLUTIONS GUIDE. Providing complete specifications utilising ABLOY SMARTair. Page 1
SMARTair SOLUTIONS GUIDE Providing complete specifications utilising ABLOY SMARTair Page 1 Table of Contents Solutions Standard Internal Applications - Standard Handle Set Page 4 - Standard Wall Reader
More informationDesign Presentation. Chief Operations Officer Willie Burroughs
Design Presentation Chief Operations Officer Willie Burroughs Agenda Introduction Community Feedback Project updates 2 Feedback Citizens Advisory Committee meetings Growth and Development meetings Community
More informationIntroduction Each adult working at the School will familiarise themselves with a copy of the detailed fire and evacuation procedure for the school.
Policy and Procedure: Fire and Evacuation Procedure Date of Board Approval: April 2018 Updated September 2018 Review date: September 2019 Introduction Each adult working at the School will familiarise
More informationEmergency Drills and Procedures. Central Bucks High School West
Emergency Drills and Procedures Central Bucks High School West By practicing emergency procedures and drills its helps to ensure student and staff safety. The more aware WE ALL ARE of the procedures in
More informationEmergency Buddy Program. Emergency Management.
Emergency Buddy Program Emergency Management https://www.ucalgary.ca/emergencyplan/ emergencymgmt.@ucalgary.ca Introduction... 1 Who may need an Emergency Buddy?... 1 Who would be a good Emergency Buddy?...
More informationFire Safety Evaluation of Existing Manufactured Educational Building Covered by Section 423 of the Florida Building Code
Walker Engineering, Inc. 833 Rockingham Road Birmingham Alabama 35235-2625 205-854-0160 205-854-0160 (Fax) Fire Safety Evaluation of Existing Manufactured Educational Building Covered by Section 423 of
More informationSecurity Considerations for Secure Workplaces
Security Considerations for Secure Workplaces Mitchell Factor HMA Consulting, Inc. USA Canada UK UAE Overview Security Risk Assessment The Process Security Design Process Technology Updates & Design Considerations
More informationOccupancy Classification and Layout Guidelines
Occupancy Classification and Layout Guidelines H3? S1? F1? B? U? H6? M? H7? A1? Presented to PIBA Seminar Group Todd LaBerge, P.E. Senior Fire Protection Engineer Presentation Overview Occupancy Groups
More informationEXISTING CONDITIONS SUMMARY
SITE Fire alarm system does meet current requirements Accessible path of travel lacking throughout campus Announcer s booth at Football Field booth not ADA compliant Covered and non covered outdoor eating
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK
2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK UK Test Laboratory School Street Willenhall WV13 3PW Contact: Mr I Bridge Tel: +44 (0) 1902 364600 Fax: +44 (0) 1902 364681 E-Mail: ian.bridge@assaabloy.com
More informationProcedure 3432P. Emergencies and Emergency Drills
Procedure 3432P Emergencies and Emergency Drills Pursuant to RCW 28A.320.125, schools are required to have site-specific safe schools plans (emergency operations plans) and procedures in place to mitigate,
More informationWhite Papers: Delayed Egress Hardware
www.sdcsecurity.com service@sdcsecurity.com [t] 800.413.8783 805.494.0622 [f] 805.494.8681 801 Avenida Acaso, C ox 3670, Camarillo CA 93011-3670 www.sdcsecurity.com White Papers: Delayed Egress Hardware
More informationSECTION DOOR HARDWARE
McClellan Blakemore Architects New Warehouse Facility for SECTION 08710 DOOR HARDWARE PART 1 GENERAL 1.01 SECTION INCLUDES A. Hardware for wood and hollow steel doors. B. Hardware for fire-rated doors.
More informationElectronic Locking Hardware Codes. Rodger Schmidt ASSA ABLOY EMSO Group HES/Folger Adams/Securitron/Adams Rite/Alarm Controls
Electronic Locking Hardware Codes Rodger Schmidt ASSA ABLOY EMSO Group HES/Folger Adams/Securitron/Adams Rite/Alarm Controls 2 Rodger Schmidt ASAA ABLOY Americas Welcome & Introductions 22+ years of Security,
More informationALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST
OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: ALARM SYSTEMS AND EVACUATION PLANS Guidelines: This checklist covers regulations issued
More informationALCORN STATE UNIVERSITY NATCHEZ CAMPUS. Emergency Procedures
ALCORN STATE UNIVERSITY NATCHEZ CAMPUS Emergency Procedures Students can be contacted regarding campus emergencies through Blackboard Connect. Please use the following link to register for Blackboard Connect.
More informationEmergency Evacuation Procedures
Emergency Evacuation Procedures Vaughn College of Aeronautics and Technology Residence Hall 22-40 90 th street When an alarm sounds, follow these fire alarm evacuation procedures: 1. Leave the building
More informationGROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES
[B] APPENDIX SR GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES The provisions contained in this appendix are adopted by the Building Codes Division of the State of Oregon. SECTION SR101 GENERAL
More informationMANUAL OF DESIGN CRITERIA AND SPECIFICATIONS FOR FIRE DETECTION AND ALARM SYSTEMS PUBLIC SCHOOLS IN NEW MEXICO
MANUAL OF DESIGN CRITERIA AND SPECIFICATIONS FOR FIRE DETECTION AND ALARM SYSTEMS PUBLIC SCHOOLS IN NEW MEXICO Prepared For: Public Schools Facilities Authority State of New Mexico 2019 Galisteo, Suite
More informationLaura Frye, AHC, CSI, CCS, FDAI Technical Director, DSSF Director of Certification, DHI
Laura Frye, AHC, CSI, CCS, FDAI Technical Director, DSSF Director of Certification, DHI Inspecting Swinging Fire Doors with Builders Hardware A Practical Guide for AHJs and Facility Management Personnel
More informationM E M O R A N D U M. All Licensed Assisted Living Facilities. Felicia Cooper, Deputy State Fire Marshal Administrator Don Zeringue, Chief Architect
M E M O R A N D U M To: From: Approved: All Licensed Assisted Living Facilities Felicia Cooper, Deputy State Fire Marshal Administrator Don Zeringue, Chief Architect Henry Fry, Deputy Assistant Secretary
More informationThe Physical Environment Portal: Module 5, LS Leadership
The Physical Environment Portal: Module 5, LS.02.01.10 - Leadership Fire Safety: Background Fire safety impacts both the lives of the occupants and the physical structures. In the early 1900 s many buildings
More informationPASS Security Plan Checklist
[School District Name] PASS Security Plan Checklist SCHOOL DISTRICT INFORMATION Address: Telephone Number: Fax Number: Number of Employees: Number of Students: School Resource Officer: TIER CONTINUUM:
More informationSchool Fire Safety Checklist
Community Risk Reduction The (SFSC) includes many of the most common fire prevention and life safety issues found in schools. The SFSC is not intended to be an all inclusive list, but rather highlights
More informationAre You Prepared? The impending impact of Code on Servicing Security Systems
Sam Docknevich, PSP, Security Service Portfolio Manager Are You Prepared? The impending impact of Code on Servicing Security Systems Siemens AG 2015 All rights reserved. usa.siemens.com/infrastructure-cities
More informationLIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE
California Society for Healthcare Engineering SOUTHERN CALIFORNIA SEMINAR LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE 1 PROGRAM AGENDA Adoption of 2012 LSC CMS Final Rule / Amendments
More informationEC EP 14 All other electrical K-920 equipment in patient care vicinity NFPA , Chapter 10
MSL Healthcare Partners, Inc. Wild Card EPs Paraphrase K-tag # EC.02.04.03 EP 14 All other electrical K-920 equipment in patient care vicinity NFPA 992012, Chapter 10 K-924 K-928 K-931 K-tag Description
More informationUniversity of Rochester October 17, 2008 Brooks Landing Business Center
SECTION 087100 - DOOR HARDWARE PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Commercial door hardware. 2. Cylinders for doors specified in other Sections. 1.2 SUBMITTALS A. Product
More informationUNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007
SECTION 08710 - DOOR HARDWARE 1.1 SUMMARY A. Door hardware required for swinging doors. No pocket or folding doors permitted at U of R. 1.2 SUBMITTALS A. Hardware Schedule: To be coordinated with doors,
More informationAddressing Sound Masking Requirements in the National Fire Alarm and Signaling Code and UL Standards
Addressing Sound Masking Requirements in the National Fire Alarm and Signaling Code and UL Standards Wayne D. Moore, P.E., CFPS, SET Vice President JENSEN HUGHES 117 Metro Center Boulevard, Suite 1002
More informationSECTION DOOR HARDWARE
PART 1 GENERAL 1.01 SUMMARY A. Section Includes SECTION 08 7100 DOOR HARDWARE The work in this section includes furnishing and installing all items of architectural hardware for aluminum, wood and hollow