1 MEMORANDUM To: From: Attendees/Absentees Derek Gallagher DG Date: June 14, 2016 Comm. No: Subject: Independent School District #879 Delano Secondary School Additions and Renovations June 6, 2016 Technology User Group Meeting Minutes Attendees: Paul Ludwig, Independent School District #879 Jon Moen, Independent School District #879 Barry Voight, Independent School District #879 Nick Main, Independent School District #879 Mary Reeder, Independent School District #879 Steve Heil, Independent School District #879 Matt Schoen, Independent School District #879 Bob Prell, ICS Consulting Karl Bohnsack, Paulson and Clark Engineering Kaitlin Schalow, Wold Architects and Engineers Patrick Triggs, Wold Architects and Engineers Derek Gallagher, Wold Architects and Engineers consult.com The Group met to discuss the preliminary User Group drawing. The drawings presented in the meeting are for diagrammatic purposes only, intended to facilitate discussion and visualize spatial adjacencies. The following is a brief summary of topics discussed. Discussion Topics: A. New Intermediate School: 1. Karl Bohnsack from Paulson and Clark Engineering gave general information about the network systems in the New Intermediate School. This information is attached to these minutes. 2. The group reviewed the technology needs of a typical classroom. a. The District is not yet sure what kind of technology will be in the classroom; teaching walls should provide electrical outlets and blank data boxes for wiring of whatever technology is chosen. b. It was noted that electrical outlets in the lockers would be ideal; however, the project was not budgeted for this. Electrical outlets should be maximized at all open wall locations.
2 MEMORANDUM Page 2 of 3 c. Classrooms should accommodate charging stations for chrome book carts. d. Ideally all data rooms should be equipped with electrical outlets and telephone connections. e. IT staff would like networked projectors at conference rooms. f. IT staff is comfortable with the size and location of data and electrical rooms in the building. g. Display TVs (as in the flex spaces) should have a hardwired network connection. h. The District wants PA alert lights in noisy locations. i. The District and Staff would like to consolidate as much of the building s technology as possible into one system. B. Secondary School: 1. Ideally the clock and PA systems at the Secondary School would be replaced. IT staff would prefer an all inclusive system running PA, Clocks, Doors, cameras, fire alarm, etc; however, this would add a considerable amount of scope to the electrical package and would likely limit the number of bidders. The district will coordinate with Bob Prell to establish a short list of potential vendors. 2. Existing info monitors use Google Digital Signage system. Hardwire data connections should be included at all new info monitor locations to accommodate this system. 3. It was noted that no intrusion detection system is currently in place at the Secondary School. Ideally, doors would be equipped to add intrusion detection in the future. 4. There will be one new data room to replace the one demolished at the Media Center. 5. If a new clock and PA system are installed, space will be required for the control equipment. It was noted that there is space in the storage room adjacent to the main data room. Partition walls between these two spaces could potentially be demolished if necessary. 6. Cooling will be required at the existing Data Room near the entry to the Media Center. 7. Ventilation required at the Data Room adjacent to the Middle School Courtyard. 8. The technology at new teaching walls in the Secondary School should match those outlined for the New Intermediate School as much as possible given existing conditions. 9. Any new lights in the project will be LED. Existing light fixtures will remain in areas untouched by major renovations. 10. Extra data and power outlets should be added at the Main Office to power specialty equipment. 11. It would be ideal to install parking lot surveillance. This would require additional power and data lines which would add to the square footage of parking lot renovation. This will be balanced against cost estimates for site work. 12. Data at the Sports Arena would be ideal, though rough ins for future data would be sufficient.
3 MEMORANDUM Page 3 of 3 C. General technology requirements: 1. It was noted that there is currently a fiber connection between the Secondary and Elementary schools. While a direct connection to the New Intermediate School would be ideal, the site for the Intermediate and the overall budget will determine whether this connection is feasible. 2. While wireless technology is planned throughout the buildings, it would be ideal to provide hardwire connections for planned equipment wherever possible to lighten the load on the wireless network. 3. CAT 6E is planned for new data cables. 4. The current security vendor for the District is Trans Alarm, but the District is ready to look for a new provider when their current contract expires. 5. The Design Team needs technology decisions from the District as soon as possible so that architectural impacts can be accommodated. 6. Wold will coordinate locations of security cameras and card reader box locations with the respective principals of the two schools. D. Next Steps: 1. The Staff will consider what equipment will require hardwired network connections and share this information with the Design Team. 2. Locations for card reader rough in will need to be determined for the Intermediate School once the building has a definite site on the campus. 3. Desired locations for security cameras will be chosen by the Principal and IT. 4. The District and Engineer will meet with vendors to explore options for the systems. Attachment cc: Traci Lawman, ISD #879 Eric Linner, Wold Vaughn Dierks, Wold Lynae Schoen, Wold MH/ISD_879/152235/min/6.6.16
4 Delano 4-6 Intermediate School Status of the following Technology Items: Paging System Clocks Fiber Cable, Telephone Network Phone Systems (VoIP) Wireless Access Points The paging system is furnished and installed under the building project. There are speakers in all classroom, offices and other student/staff areas. One (1) Zone for entire school, including exterior speakers. Allows connection with a phone system. *Blue notification strobes will be provided at several areas to give visual indication of an ongoing broadcast. Clocks are furnished and installed under the building project. Battery clocks connect to central Radio Frequency (RF) time server, Primex or American Time. Time server can schedule class changes and interface with the PA system for notification (if required) The building project will furnish and install 24 pair fiber optics (FO) from Demarcation near Electrical Room to the Main Server Room. 12 pair fiber optics from Main Server Room to the other IDF Room. FO will be terminated and tested (no electronic converters or switches are included) The Owner shall contact the utilities for installation into the building. This includes Electrical utility (local power company is aware of our project), Cable TV (if required in the school), telephone (copper analog lines are required for elevator and fire alarm) & Network/Internet (this can be done through a Telephone Utility or a private Fiber Optic connection). Empty conduits will be installed into the building to facilitate utility cabling. The building project will furnish and install network (data &Voip) Cat 6e cabling from all outlet locations to patch panels in the IDF or Main Server Room. The cabling will be tested and labeled to district standards. Network Switches to be furnished and installed by the Owner or separate Vendor. Owner to patch to the Switches. The purchase of the phone and the phone system will be by the Owner. Installation by the Owner or separate Vendor. WAP connection points are located throughout the public spaces every 100, near conference rooms, office areas, 2 in the cafeteria and gymnasium and in every classroom. They include an outlet located above the ceiling with 2 data cables to each location (next generation access point can utilize 2 cables for greater coverage). The Wireless Access Point device is to be furnish and installed by the Owner or separate Vendor.
5 Voice Enhancement Systems Document Cameras Door Access Control Building Intrusion Security Cameras Duress/Panic System The building project to furnish and install the Voice Enhancement System for the Gymnasium and the Cafeteria. If Voice Enhancement Systems for the Classroom areas is required, it shall be furnished and installed by the Owner or separate Vendor. Classrooms have empty boxes and conduits that can be used for these types of devices if they are not connected to the Teachers computers. If specific requirements are needed in each classroom, please provide requirements and locations. The building project will furnish and install rough-in (conduit and j-box) for Card Readers at the Main Entry and other doors as required. The building project will furnish and install electronic door hardware, and power supplies. Card Reader devices and door access computer system to be furnished and installed by the Owner or separate Vendor. Exterior door intrusion contacts shall be furnished and installed by the Owner or separate Vendor. The Building project to provide conduit from top door frames to accessible ceilings above. The Security Camera System to be furnished and installed by the Owner or separate Vendor. The building project will furnish and install one (1) lockdown button at the receptionist desk; this will include buttons for local door control. The system will provide connections to release doors that are held open by magnetic hold opens connected to the fire alarm system. The building project will furnish and install the connections from the lockdown button to the fire alarm panel to release the doors. The building project will furnish the buttons and wiring to locally control the new entry doors. Any door Access Computer system can be furnished and installed by the Owner or separate Vendor in the future.
6 Fixture Type : Volumetric Troffer, 4800 Lumen 4100 color Temp, Fully Dimmable LED. OS N1 LD1 Low voltage switch with On/Off and Dimmable levels. Dimming levels include all fixtures. Lighting in manual on to 75% and can be turned up for testing or as needed. Ceiling Occupancy Sensor turns off power to all room lighting after 30 min unoccupied 1 Classroom Lighting 1/8" = 1'-0" BLT Series LED 2BLT 2' x 4' LED Specifications Length: 47-3/4 (121.2) Width: 23-3/4 (60.3) Depth: 2-3/8 (6.0) All dimensions are inches (centimeters) unless otherwise specified.
7 Teacher Station Low: Receptacle, 3Data & SB Box Above Desk: Receptacle & SB Box SB box and conduit to ceiling can be used for wired enhanced audio systems if installed (SB) locations are rough-in of 2 gang deep box for classroom technology input and video connections. Smartboard / TV / Wall Projector Low: Receptacle & Data Jack High: Receptacle & J-Box for LV cable SB J SB J 36" 36" 84" 84" Receptacle flush in ceiling for projector Receptacle & empty box for future cabling S Fire Alarm Notification Device F WAP S Buildings Public Address system speaker (Typ 2) 2 data jacks terminated above ceiling for Wireless Access Point C Duplex Receptacle AB AB Duplex Receptacle & 2 Data Jacks If classroom has countertop: GFI Duplex Receptacle mounted Above Backsplash of the counter Wireless Clock 1 Classroom Coordination 1/8" = 1'-0"
Electrical Inspection Special Electrical
0941 Fire Alarm System Devices, panels, wiring, conduit, etc. The present fire alarm system manufactured by Gamewell was installed with the 1982 renovation. It is a non addressable, zoned system. It includes
More informationPLATTEVILLE MIDDLE SCHOOL
Architectural The building has aluminum clad wood awning windows in combination with aluminum fixed glass units. They appear to be exterior glazed with insulated glazing. See photo 2. Platteville Middle
More informationPROPOSED SCOPE OF WORK
WATERTOWN CITY SCHOOL DISTRICT SCHOOL AND COMMUNITY WORKING TOGETHER SMART SCHOOLS PROJECT PROPOSED SCOPE OF WORK BCA PROJECT NO. 2017-100 NOVEMBER 2, 2017 Prepared By: & 327 Mullin Street 2136 Five Mile
More informationGARCIA GALUSKA DESOUSA Consulting Engineers
L#57297 /Page 1/July 21, 2017 ELECTRICAL SYSTEMS NARRATIVE REPORT The following is the Electrical Systems narrative, which defines the scope of work and capacities of the Power and Lighting systems, as
More informationDIVISION 28 ELECTRONIC SAFETY AND SECURITY
DESIGN CONSIDERATIONS DIVISION 28 ELECTRONIC SAFETY AND SECURITY The Consultant shall provide a written description of how the entire system is designed to operate. This Basis of Design (BOD) narrative
More informationElectrical Inspection Special Electrical
0941 Fire Alarm System Devices, panels, wiring, conduit, etc. Description of the building system The school is equipped with a hard wired fire alarm control panel, and automatic dialer. The fire alarm
More informationTAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE
TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE The University of Arizona has implemented a Keyless Access and Security System program to provide a cost effective, efficient, and maintainable means
More informationElectronic Safety and Security
28 Electronic Safety and Security NOTE: This is a new section, which includes content from previous sections of the KU Design Standards, along with appropriate revisions and updates. Significant revisions
More informationMEDIA CENTER September 30, 2010
MEDIA CENTER September 30, 2010 I. PROGRAM REQUIREMENTS Refer to the project-specific Schedule of Spaces for student stations, square footage, and for any requirements that may differ from the prototype
More informationHOLUM EDUCATION CENTER. Architectural. January 13, 2014 DeForest Area School District
HOLUM EDUCATION CENTER Architectural The existing building has approximately 41,823 square feet and sets on a lot about 4.14 acres in size. Parking lots are located along the east and west sides of the
More informationF. GENERAL REQUIREMENTS Electrical Design Criteria 2006 Edition 4/3/06 School District Palm Beach County Page-1 of 15
ELECTRICAL DESIGN CRITERIA TABLE OF CONTENTS I GENERAL...2 II CRITERIA...2 A. POWER DISTRIBUTION SYSTEMS...2 1. NORMAL POWER:...2 2. EMERGENCY POWER...3 B. LIGHTING...4 1. GENERAL...4 2. AVERAGE MAINTAINED
More informationF. GENERAL REQUIREMENTS Electrical Design Criteria 2009 Edition 11/23/2009 School District Palm Beach County Page-1 of 17
ELECTRICAL DESIGN CRITERIA TABLE OF CONTENTS I GENERAL...2 II CRITERIA...2 A. POWER DISTRIBUTION SYSTEMS...2 1. NORMAL POWER:... 2 2. EMERGENCY POWER... 3 B. LIGHTING...4 1. GENERAL... 4 2. AVERAGE MAINTAINED
More informationWold Architects and Engineers. 332 Minnesota Street Suite W2000 Saint Paul, MN
Wold Architects and Engineers 332 Minnesota Street Suite W2000 Saint Paul, MN 55101 651 227 7773 PLANNERS ARCHITECTS ENGINEERS ISD #15 St. Francis Area Schools East Bethel Elementary School Additions and
More informationGarfield Elementary School Feasibility Study for New Library Building Project Number A C
Larry Teixeira Selma Unified School District 3036 Thompson Avenue Selma, CA 93662 Subject: Feasibility Study for New Library Building Project Number A 12-8581.00 C Dear Mr. Teixeira: At your request, we
More informationCLEVELAND HEIGHTS UNIVERSITY HEIGHTS CITY SCHOOL DISTRICT MONTICELLO & ROXBORO MIDDLE SCHOOLS INTERIOR DESIGN
CLEVELAND HEIGHTS UNIVERSITY HEIGHTS CITY SCHOOL DISTRICT MONTICELLO & ROXBORO MIDDLE SCHOOLS INTERIOR DESIGN 04.13.2017 1 MONTICELLO INTERIOR FINISHES PAINT MOULDING WALLS ACCENT DOORS DOOR TRIM/STAIRS
More informationCRESTRON MEDIAMANAGER INTELLICLASS
CRESTRON MEDIAMANAGER INTELLICLASS Crestron IntelliClass systems provide educators with a simplified yet comprehensive classroom presentation solution that saves time and money. Designed to deliver the
More informationSECTION PUBLIC ADDRESS SYSTEMS
PART 1 GENERAL 1.1 SECTION INCLUDES A. Amplifier and control equipment B. Input equipment C. Raceways and communications cable D. List of equipment for gym PA system E. List of equipment for cafeteria
More informationRenovate MCRC Facilities Great Lakes, IL
6. ENGINEERING SYSTEMS REQUIREMENTS D50 ELECTRICAL SYSTEM DESCRIPTION The electrical repair work includes the design and construction of the electrical distribution system for the B3200 Marine Corps Reserve
More informationArlington Public Schools Purchasing Office
Arlington Public Schools Purchasing Office NOTICE OF ADDENDUM NO. 1 Issued on March 30, 2018 TITLE: ITB NO.: YORKTOWN HIGH SCHOOL INTERIOR MODIFICATIONS PROJECT 57FY18 ITB CLOSING DATE PRIOR TO 2:00 P.
More informationLIGHTING CONTROLS
260923 LIGHTING CONTROLS PART 1: GENERAL 1.01 SUMMARY COMMENTS A. CU has developed this lighting control guideline to direct design professionals toward standard solutions that meet the University s performance
More informationPROJ. NO SECTION PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS
SECTION 26 92 50 PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More information2017 UPDATE AUDIO/ VIDEO &SMART HOME PREWIRE. QUICK GUIDE A reference for low voltage wiring.
2017 UPDATE AUDIO/ VIDEO &SMART HOME PREWIRE QUICK GUIDE A reference for low voltage wiring. INTRODUCTION Thanks for downloading our Prewire Quick Guide. We created it to be a helpful resource for our
More information2015 Building Condition Survey Summary Mosaic Associates Architects 02/19/16
1. General: This summary is offered as a supplement to the 2015 Building Condition Survey being filed with SED on behalf of the District. All cost estimates are preliminary, and should be re-evaluated
More informationWPUMC Capital Report Existing Facilities February 19, Maintenance Coordinator George Smit
WPUMC Capital Report Existing Facilities February 19, 2017 Maintenance Coordinator George Smit Facility Overview Buildings Sanctuary Building (SB) Sanctuary, Narthex, Lobby Choir Room. Dr. Lee s Office,
More information7/14/2016 CITY HALL ADA ENHANCEMENT/REMODEL ACTION PLAN 1978 Construction
CITY HALL ADA ENHANCEMENT/REMODEL 2016 ACTION PLAN 1978 Construction 1 HISTORY At the February 2, 2016 Council Workshop Council Motions included: The direction to staff to move forward with the City Hall
More informationSimple Security Improvements Can Go A Long Way
Simple Security Improvements Can Go A Long Way James Henderson, AIA and William Laughlin, AIA, REFP As communities across our nation seek to understand the tragedies that have struck schools, the safety
More informationDIGITAL HOME TECHNOLOGIES
LIFESTYLE QUESTIONNAIRE We would appreciate you taking the time to review and complete our Lifestyle Questionnaire. Our intent is to make you aware of the many options available when considering the purchase
More informationFlorence High School / Middle School Page 1 of 3 Florence, WI
Florence High School / Middle School Page 1 of 3 Florence, WI Plumbing Systems Review: The following report is the result of a site visit by Tim Kehoe of Muermann Engineering, LLC that occurred on October
More informationCity of La Puente REQUEST FOR PROPOSAL ADDENDUM NO. 1
City of La Puente REQUEST FOR PROPOSAL ADDENDUM NO. 1 BID TITLE: Facility Access Control and Security System REQUESTING DEPARTMENT: Development Services RELEASE DATE: July 12, 2016 DUE DATE: August 4,
More informationSpringpoint Architects, pc SECTION Childcare Center Architect s Project No TABLE OF CONTENTS Monroe County Comm. Sch. Corp.
Volume 1 Bidding Requirements, Contract Forms, Conditions of the Contract, Division 1, Architectural and Site Specifications 000107 Certification Page 000110 Table of Contents DIV00 PROCUREMENT AND CONTRACTING
More informationBSD Technical Standard. Division 28: Electronic Safety & Security
Division 28: Electronic Safety & Security I. PURPOSE This Technical Standard is a narrative describing Beaverton School District s (BSD s) basis of design for electronic safety and security in BSD facilities.
More informationTelecommunications Survey
Victor Valley College Telecommunications Survey Victor Valley College 18422 Bear Valley Road Victorville, CA 92395 November 30, 2010 Submitted by P2S Engineering, Inc. Executive Summary Background and
More informationFIRE ALARM: BY OTHERS, IF REQUIRED.
x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. CAPITAL LETTER DENOTES TYPE, LOWER CASE LETTER DENOTES SWITCH LEG. FLUORESCENT STRIP LIGHT FIXTURE,
More informationSTATEMENT OF WORK. System Description:
STATEMENT OF WORK Scope of Work: To install a paging/sound system throughout the Rapid City Swim Center (RCSC). This work shall includes all labor, material equipment and related services necessary to
More informationOmniPro II. Technical Sheet. DESCRIPTION
OmniPro II Technical Sheet DESCRIPTION The OmniPro II is HAI s flagship home control and security system. It is designed for large residences and commercial installations. The system provides enhanced
More informationMOUNT PLEASANT MIDDLE SCHOOL HVAC. M-01 Heating Plant: M-02 Heating & Ventilating Systems: Livingston School District Mount Pleasant Middle School
MOUNT PLEASANT MIDDLE SCHOOL HVAC M-01 Heating Plant: The existing boilers have recently been upgraded. (3) steam boilers (8660 mbh each) manufactured by Weil- McLain have been installed. Newer hot water
More informationCharleston excellence is our standard County SCHOOL DISTRICT
Charleston excellence is our standard County SCHOOL DISTRICT FACILITY SECURITY ACCESS CONTROL, INTRUSION DETECTION, AND SURVEILLANCE DESIGN SPECIFICATIONS FOR NEW CONSTRUCTION, ADDITIONS, AND MAJOR RENOVATIONS
More informationFIRE ALARM: BY OTHERS, IF REQUIRED.
x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. FLUORESCENT STRIP LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. WALL BRACKET FLUORESCENT
More informationSECTION INTRUSION DETECTION
(NOTE TO DESIGNER: These Specifications are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer.) SECTION 28 16 00 INTRUSION
More informationPrinceton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors
Princeton Joint Unified School District Invitation for Bid Installation of District-Wide Lighting Occupancy Sensors 1. SUMMARY AND BACKGROUND: Princeton Joint Unified School District located in Princeton
More information2014 Bond Project Guide
2014 Bond Project Guide Bush Elementary School Page 1 Instructional Technology Computers, Projectors, Mobile Carts, Document Cameras and Printers Wireless Connectivity New Construction New Tech Center
More informationThe WAVE Plus Instant Notification System for Schools and Colleges
Instant Notification System for Schools and Colleges Duress alarm has been activated in the School of Engineering! Schools strive to provide a safe environment for students and teachers. In an emergency,
More informationThe Leaders in Security and Life Safety Communications
The Leaders in Security and Life Safety Communications K 12 SECURITY & LIFE SAFETY COMMUNICATIONS SOLUTIONS SAFETY FOR YOUR SCHOOL INSIDE AND OUT When it comes to school facilities and campuses, nothing
More informationCONSTRUCTION MANUAL PART 4
CONSTRUCTION MANUAL PART 4 Technical Specifications and Standards Revised June 21, 2016 Original Issue Date: February 9, 1990 Revisions January 16, 2019 November 8, 2018 August 10, 2017 August 4, 2016
More informationDIVISION 13 - SPECIAL CONSTRUCTION
DIVISION 13 - SPECIAL CONSTRUCTION I. GENERAL A. This division contains the following elements: 1. Relocatable Buildings. 2. Telephone and Data Systems. 3. Intercom and Clock/Bell System. 4. Wiring and
More informationAlertWave Smart Wireless Solutions for Today s Campus Whether you are a large university
Introduction AlertWave Smart Wireless Solutions for Today s Campus Whether you are a large university seeking a comprehensive packaged solution or a community college looking for a detailed solution on
More informationAbout IntraLogic. In Business since 2004 Over 55 Full time employees
Security Services In Business since 2004 Over 55 Full time employees About IntraLogic National & State Contracts including OGS / GSA Our sales & system design team all have security backgrounds Clients
More informationHome Automation. Product info. Marketed By: BlueSilica Technologies For further details write to
Home Automation Product info Marketed By: BlueSilica Technologies www.bluesilica.com For further details write to bluesilica@gmail.com Home Automation Home automation is the latest in a high-tech world
More informationMAZAGON DOCK SHIPBUILDERS LIMITED
MAZAGON DOCK SHIPBUILDERS LIMITED (Formerly known as Mazagon Dock Ltd.) CIN : U35100MH1934GOI002079 (A Government of India Undertaking) Shipbuilders to the Nation Dockyard Road, Mazagon, Mumbai 400 010.
More informationSECTION INTERCOMMUNICATION SYSTEM 1. GENERAL 1.1 DESCRIPTION
SECTION 27 51 23 INTERCOMMUNICATION SYSTEM 1. GENERAL 1.1 DESCRIPTION A. The requirements of the contract documents, including the General and Supplementary General Conditions and Division 1 - General
More informationSCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL
SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm
More informationMaster Facility Planning Update School Board Meeting May 26, 2016
Master Facility Planning Update School Board Meeting May 26, 2016 Master Facilities Committee Overview Reflection of Committee Work Review of District Wide Facility Issues Identified District Wide Facility
More informationDraft. Security Study. Germantown School District Germantown, WI. PRA Project # February 2014
Draft Security Study Germantown School District Germantown, WI PRA Project # 114440 February 2014 February 2014 Germantown School District Facilities Security Study Page 1 Facilities Security Study Page
More informationDEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and
DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and equipment), and discussions with maintenance personnel
More informationM001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings
1 T Consultant: NOTES, SYMBOLS & ABBREVIATIONS - MECHANICAL Number Description M001 Vestibule 117 LAN/IT Coffee 115 116 Mail Room 118 114 113 112 Scanning 119 Open Office 101 FIRST FLOOR PLAN - MECHANICAL
More informationRFP Addendum 2 March 31, 2016
RFP Addendum 2 March 31, 2016 For Best Value Procurement Option Three Security Upgrades Ph 1 UT Health Science Center SBC No. 540/013-04-2015 This Addendum forms a part of the Request for Proposals (RFP)
More informationLibrary stacks and records storage 150 LB/SF live load
SPACE TYPE: LIBRARY Construction Criteria The unit costs for Library space types are based on the construction quality and design features in the following table. This information has been generally organized
More informationAMENDMENT NO.: III INVITATION FOR BID NO.: GPA FOR
January 26, 2018 AMENDMENT NO.: III TO INVITATION FOR BID NO.: GPA-022-18 FOR PHYSICAL SECURITY AND ACCESS CONTROL SYSTEM (ACS) REPAIR AND UPGRADE AT VARIOUS GPA LOCATIONS Prospective Bidders are hereby
More informationMAZAGON DOCK SHIPBUILDERS LIMITED
MAZAGON DOCK SHIPBUILDERS LIMITED (Formerly known as Mazagon Dock Ltd.) CIN : U35100MH1934GOI002079 (A Government of India Undertaking) Shipbuilders to the Nation Dockyard Road, Mazagon, Mumbai 400 010.
More informationFor Dealers / Integrators / Architects. IS Series. Video Intercom. Building Communication. Controlling Security.
For Dealers / Integrators / Architects IS Series Video Intercom Building Communication. Controlling Security. IS Series helps save money Control multiple functions from any location to help reduce overall
More informationSPECIFICATION SUBMITTAL
SPECIFICATION SUBMITTAL The dimmer with remote control One tap on to selected light level/off; two taps full bright;press & hold for 10-second fade-tooff Press rocker to adjust light level Front accessible
More informationElement C Interiors Interior Construction
Fittings and Interior PART 1 - GENERAL 1.01 OVERVIEW A. Includes marker and tack boards, lockers, storage shelving, handrails and wall protection, access doors, aquariums, fire extinguishers, and signage.
More informationAttachment F. Campus Capital Needs Sales Surtax Funded Detail Report
Facility Attachment F Campus Capital Needs Sales Surtax Funded Detail Report Facilities Services 2700 Judge Fran Jamieson Way Viera, Florida 32940-6601 Condition Code Estimate Longleaf Elementary 1.78
More informationThe OmniPro II EN50131 and PD6662 Compliant Controller
The OmniPro II EN50131 and PD6662 Compliant Controller omni APPLICATION The OmniPro II is the flagship security & automation controller. Designed for large residential and commercial installations, the
More informationThe Omni LTe EN50131 and PD6662 Compliant Controller
The Omni LTe EN50131 and PD6662 Compliant Controller omni APPLICATION The Omni LTe is a full sized security and automation system with flash memory and five serial ports, as well as an Ethernet port for
More informationL04 X01 X03 X01 R21A R21A F09 L27 R18 R16A R18 R21A KING 107 F09 F09 L27 D03A Z-38 KING 109 R21A R18 R16A R18 R21A F09 F09 X03 L27 F09 R21A R18 R18
REFERENCE NOTES A. SEE 0 SERIES DRAWINGS FOR CEILING & LIGHTING IN GUESTROOMS. B. SEE 00 SERIES DRAWINGS FOR CEILING & LIGHTING INFORMATION & DETAILS IN PUBLIC SPACE. C. PROVIDE EMERGENCY LIGHTING AND
More information2015 List of Exempt Machinery and Equipment Steel Products The Department of General Services (DGS) has reviewed all comments and supporting documentation received prior to the end of the thirty-day (30)
More informationMichigan State University DESIGN GUIDELINES. ELECTRICAL DESIGN Page 1 TABLE OF CONTENTS 1
Page 1 TABLE OF CONTENTS 1 ELECTRICAL 2 Summary Sustainability Electrical Distribution Lighting Detection and Alarm Communication Systems Lightning Protection Clock Systems Access Control Housekeeping
More informationTechnical Report 2: Electrical Systems Criteria and Existing Conditions
Technical Report 2: Electrical Systems Criteria and Existing Conditions Princeton Theological Seminary Library Princeton, NJ Stephanie Deckard Lighting Electrical Faculty Advisor Dr. Kevin Houser 10/12/2012
More informationAlertWave. visiplex. From a Public Address System to an Emergency Communication System... The AlertWave system advantages:
AlertWave From a Public Address System to an Emergency Communication System... The AlertWave offers facility managers an easy way to implement an on-site wireless public address, emergency control and
More informationH107 Video Conference Room
Capacity: 20 persons White Board (1) Document Camera (1) Door (1) Network connections possible Layout: Seminar style with chairs and tables (moveable) Podium (1) Media Cart (1) Windows (4) Meets all ADA
More informationGENERAL ASSIGNMENT CLASSROOM DESIGN STANDARDS
University of Iowa FSG - Design & Construction Services Design Reference Manual 2 Design Standards 2.02 Classroom Design Standards Classroom Design Standards GENERAL ASSIGNMENT CLASSROOM DESIGN STANDARDS
More informationALBUQUERQUE PUBLIC SCHOOLS Facility Design & Construction / Maintenance & Operations ELECTRICAL STANDARDS DESIGN CHECKLIST
ALBUQUERQUE PUBLIC SCHOOLS Facility Design & Construction / Maintenance & Operations ELECTRICAL STANDARDS DESIGN CHECKLIST February 01, 2006 2 Project Name: Architect: Electrical Engineer: Completed By:
More informationEducation. Life Safety and Security Door Hardware. Integrated Door Security Systems. Safety, Security and Risk Management
Education Life Safety and Security Door Hardware Integrated Door Security Systems Safety, Security and Risk Management Door hardware made for A+ reliability More than just for main doors, Detex hardware
More informationHMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California ADDENDUM NO. 3
HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California 95833 September 15, 2016 Woodland Joint Unified School District Spring Lake Area Elementary School HMC No. 3535003.000 DSA Appl.
More informationWhite Bear Lake Area Schools District 624 ENERGY GUIDELINES
White Bear Lake Area Schools District 624 ENERGY GUIDELINES Developed by: White Bear Lake Area Schools Energy Steering Committee as part of the Schools for Energy Efficiency (SEE) Program ISD 624 Energy
More informationANNEXURE-III BUILDING MANAGEMENT SYSTEM (BMS) BMS Total ANNEXURE-III. SL DESCRIPTION OF ITEM UNIT QTY Rate in figures Rate in words AMOUNT
PRICE BID Name of the Project : Supply, Installation, Testing and Commissioning of BMS, PA, CCTV, AVS, Access Control System for Construction of Partially completed Building at Centre for Development of
More informationDIVISION 28 ELECTRONIC SAFETY AND SECURITY
281300 - ACCESS CONTROL A. General DIVISION 28 ELECTRONIC SAFETY AND SECURITY At the beginning of the project, schedule a meeting with the Facilities Access/Maintenance Coordinator with questions and concerns.
More informationState College Area School District Office of Physical Plant Ed Poprik, Director
State College Area School District Office of Physical Plant Ed Poprik, Director VI-B To: From: RE: Board of School Directors Ed Poprik High School project 30% document review Date: October 13, 2014 Attached
More informationDUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD
DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD LIGHTING FIXTURES AND CIRCUITRY & SWITCHING SECONDARY SCHOOLS 1. GENERAL 1.1.1. Consultants MUST prepare a Summary of Fixtures which will include catalogue
More informationThe Omni IIe EN50131 and PD6662 Compliant Controller
The Omni IIe EN50131 and PD6662 Compliant Controller omni APPLICATION Omni IIe is an ideal and economical choice for homes and small businesses. The system provides enhanced comfort, safety, convenience
More informationBusiness Owner s Security Buyers Guide
Business Owner s Security Buyers Guide You re a business owner. That means you wear a lot of hats including that of the security manager. One of your many jobs is to protect your customers, employees,
More informationSafety & Security. Plainview-Old Bethpage Central School District
Safety & Security Plainview-Old Bethpage Central School District Agenda Security Enhancements 2017/2018 School Year Emergency Drill Requirements, Training & Expectations In-Progress Security Enhancements
More informationUK Police. University Senate Council 2/10/2016. Authorized by KRS Now considered the 11 th largest police department in Kentucky.
University Senate Council Update on Campus Security 2/8/20156 1 UK Police Authorized by KRS 164.950 Now considered the 11 th largest police department in Kentucky. Largest University Police in Kentucky
More informationCOSMETOLOGY September 30, 2010
COSMETOLOGY September 30, 2010 I. PROGRAM REQUIREMENTS Refer to the project-specific Schedule of Spaces for student stations, square footage, and for any requirements that may differ from the prototype
More informationEmergency Management Resource Guide. Appendix A: Crime Prevention Through Environmental Design CPTED Principles Checklist for Kentucky Public Schools
Appendix A: Crime Prevention Through Environmental Design CPTED Principles Checklist for Kentucky Public Schools 143 Crime Prevention Through Environmental Design CPTED Principles Checklist for Kentucky
More informationDIXON UNIFIED SCHOOL DISTRICT DIGITAL INTERCOM / CLOCK & BELL SYSTEM
DIXON UNIFIED SCHOOL DISTRICT DIGITAL INTERCOM / CLOCK & BELL SYSTEM PART 1 GENERAL 1. SECTION INCLUDES a. Furnish and install a complete computer based and controlled voice communications system with
More informationThe Omni IIe Controller
The omni APPLICATION Omni IIe is an ideal and economical choice for homes and small businesses. The system provides enhanced comfort, safety, convenience and energy savings by coordinating audio, lighting,
More informationELECTRICAL SYSTEMS ASSESSMENT Hanover High School
ELECTRICAL SYSTEMS ASSESSMENT Hanover High School ELECTRICAL DISTRIBUTION SYSTEM:?? The existing electrical service consists of an underground primary service originating at a utility pole on Cedar Street,
More informationBrighton Area Fire Authority
615 W. Grand River Ave. Brighton, MI 48116 o: 810-229-6640 f: 810-229-1619 January 14, 2019 Fire Alarm Contractors RE: Fire Alarm Credential & Submittal Requirements To Whom It May Concern: The following
More informationState College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT
State College Area School District High School South Building Prepared by CenterPoint Engineering 08 February 2013 FACILITY ASSESSMENT SUMMARY PHYSICAL PLANT General HVAC This report is a snapshot of the
More informationTelecommunications Addendum APPLICATION FOR CLASSIFICATION/TELECOMMUNICATIONS
Telecommunications Addendum State of New Jersey Department of the Treasury Division of Property Management & Construction Contractor Classification Unit P.O. Box 034 33 West State Street 9th Floor Trenton,
More informationLONG-RANGE PLANNING COMMITTEE
2018-2019 Improvements of Campus Facilities Current/In Progress: Improvements began with the 2014 Bond Program: Security vestibules at front entries with video cameras and buzzer door releases Reinforced/bullet-resistant
More informationState College Area School District High School North Building EXISTING CONDITIONS ASSESSMENT
State College Area School District High School North Building Prepared by CenterPoint Engineering 08 February 2013 FACILITY ASSESSMENT SUMMARY PHYSICAL PLANT General HVAC This report is a snapshot of the
More informationDIVISION 28 ELECTRONIC SAFETY AND SECURITY
DIVISION 28 ELECTRONIC SAFETY AND SECURITY CENTRALLY MANAGED ELECTRONIC ACCESS CONTROL, VIDEO SURVEILLANCE, AND INTRUSION ALARM SYSTEMS 1. All questions on equipment approvals in this section shall be
More informationCRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1
GREEN LIGHT ARCHITECTURAL DIMMING CONTROLS (GLPD) Crestron Green Light and Green Light Express Network Dimming Control Systems are web accessible, network connected dimming control systems that receive
More informationDIVISION 13 SPECIAL CONSTRUCTION
DIVISION 13 SPECIAL CONSTRUCTION This division contains the following elements: 1.1 General. 1.2 Utility Provisions for Future Expansions. 1.3 Telecommunications Systems. 1.4 Intercom and Clock/Bell System.
More informationLincoln Public Schools
Lincoln Public Schools School Building Committee Meeting February 13, 2019 Today s Agenda 1. Review Updated Site Plan 2. Review and Approve OPR 3. Review MEP Systems 4. Review Progress Energy Model Review
More informationSPACE TYPE: JUDICIAL CHAMBER
SPACE TYPE: JUDICIAL CHAMBER Construction Criteria The unit costs for Judicial Chamber space types are based on the construction quality and design features in the following table. This information has
More informationSchool Paging. IP/SIP Intercom and Paging. Prepared by: John Vellone
School Paging IP/SIP Intercom and Paging OVERVIEW Perform point to point or campus wide communication with controlled evacuation via pre-recorded messages and/or via emergency microphones using the Fonica
More information