Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Size: px
Start display at page:

Download "Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed."

Transcription

1 THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models W7A to W7A Right-ide Control Panel Models W7L to W7L Left-ide Control Panel. to Ton (, to, Btuh) The Bard Wall-Mount Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities. Factory or field installed accessories are available to meet specific job requirements. Green Refrigerant R-A Engineered Features Aluminum Finned Copper s: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. Twin Blowers: Move air quietly. Most models feature multispeed blower motors providing airflow adjustment for high and low static operation. Motor overload protection is standard on all models. Air Conditioner Compressor: croll Compressors eliminate need for crankcase heater. tandard on all models. R-A Refrigerant: Designed with R-A (HFC) non-ozone depleting refrigerant in compliance with the Montreal protocol and EPA requirements. Phase Rotation Monitor: tandard on all 3 phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Galvanized Gauge Zinc Coated teel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand hours of salt spray tests per ATM B7-3. Foil Faced Insulation: tandard on all units. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Electrical Components: Are easily accessible for routine inspection and maintenance through a right side, service panel opening. Features a lockable, hinged access cover to the circuit breaker or toggle disconnect switch. Electric Heat trips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. Filter ervice Door: eparate service door provides easy access for filter change. One Inch, Disposable Air Filters: Are standard equipment. Optional one inch washable filters available and filter racks permit the addition of " pleated filter. Factory or field installed. Condenser Fan and Motor hroud Assembly: lides out for easy access. Barometric Fresh Air Damper: tandard on all units. Allows up to % outside fresh air. Optional ventilation packages available. Built-in Circuit Breakers: tandard on all electric heat versions of single (3/ volt) and three phase (3/ volt) equipment. Toggle disconnects are standard on all electric heat versions of three phase ( volt) equipment. lope Top: tandard feature for water run-off. Top Rain Flashing: tandard feature on all models. Liquid Line Filter Drier: tandard on all units. Protects system against moisture. Compressor Control Module: tandard on all units. Built-in off-delay timer adjustable from 3 seconds to minutes. -minute on-delay if power interrupt. -second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay. High & Low Pressure witches are Auto-Reset: tandard on all units. Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Complies with efficiency requirements of AHRAE/IENA.-. Certified to ANI/ARI tandard 3-3 for PVU (ingle Package Vertical Units). Intertek ETL Listed to tandard for afety Heating and Cooling Equipment ANI/UL /CA. No. 3-, Fourth Edition. Commercial Product - Not intended for Residential application. Form No. 3-3 upersedes 3-3 Page of

2 Capacity and Efficiency Ratings Models W7A / WA W7L / WL WA WL W3A W3L W3A W3L Capacity is certified in accordance with ANI/ARI tandard 3-3. EER = Energy Efficiency Ratio and is certified in accordance with ANI/ARI tandard 3-3. All ratings based on fresh air intake being % closed (no outside air introduction). WA WL WA WL WA WL W7A W7L Cooling Capacity BTUH, 3,,,,,,, EER pecifications -/ Ton through 3 Ton MODEL W7A-A W7L-A WA-A WL-A WA-A WL-A WA-B WL-B WA-C WL-C W3A-A W3L-A W3A-B W3L-B W3A-C W3L-C W3A-A W3L-A W3A-B W3L-B W3A-C W3L-C Electrical Rating Hz 3/ - 3/ - 3/ - 3/ / - 3/ / - 3/ Operating Voltage Range Compressor--Circuit A Voltage 3/ 3/ 3/ 3/ 3/ 3/ 3/ 3/ Rated Load Amps./7..3/7../..3/7.3../3. 7./...3/7..3/.7. Branch Circuit election Current Lock Rotor Amps / / / / 77/77 7/7 3 / / Compressor Type croll croll croll croll croll croll croll croll croll croll croll Fan Motor & Condenser Fan Motor--HP--RPM / - / - / - / - / - / - / - / - / - / - / - Fan Motor--Amps Fan--DIA/CFM " - 7 " - 7 " - 7 " - 7 " - 7 " - " - " - " - " - " - Blower Motor & Evap. Blower Motor--HP-RPM-PD /-- /-- /-- /-- /-- /3-- /3-- /3-- /3-- /3-- /3-- Blower Motor--Amps CFM Cooling & E..P. w/filter (Rated- ) Filter izes (inches) TD. xx xx xx xx xx x3x x3x x3x x3x x3x x3x hipping Weight --LB pecifications 3-/ Ton through Ton MODEL WA-A WL-A WA-B WL-B WA-C WL-C WA-A WL-A WA-B WL-B WA-C WL-C WA-A WL-A WA-B WL-B WA-C WL-C W7A-A W7L-A W7A-B W7L-B W7A-C W7L-C Electrical Rating Hz 3/ - 3/ / - 3/ / - 3/ / - 3/ Operating Voltage Range Compressor--Circuit A Voltage 3/ 3/ 3/ 3/ 3/ 3/ 3/ 3/ Rated Load Amps./7../.. /3. 3./.7./. 3/. 7. / /.3. Branch Circuit election Current Lock Rotor Amps / 3./3. 3/3 / 3/3 / / / Compressor Type croll croll croll croll croll croll croll croll croll croll croll croll Fan Motor & Condenser Fan Motor--HP--RPM-PD /3-- /3-- /3-- /3-- /3-- /3-- /3-- /3-- /3-- /-- /-- 3/-- Fan Motor--Amps Fan--DIA/CFM " - 7 " - 7 " - 7 " - 7 " - 7 " - 7 " - " - " - " - " - " - Blower Motor & Evap. Blower Motor--HP-RPM-PD /3-- /3-- /3-- /3-- /3-- /3-- /-7- /-7- /-7- /-7- /-7- /-7- Blower Motor--Amps CFM Cooling & E..P. w/filter (Rated- ) Filter izes (inches) TD. x3x x3x x3x x3x x3x x3x x3x x3x x3x x3x x3x x3x hipping Weight --LB. Form No. 3-3 upersedes 3-3 Page of

3 Ventilation ystem Packages Bard Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a barometric fresh air damper as the standard ventilation package. All ventilation packages can be built-in at the factory or fieldinstalled at a later date. BAROMETRIC FREH AIR DAMPER - BFAD TANDARD The barometric fresh air damper is a standard feature on all models. It is installed on the inside of the service door and allows outside ventilation air, up to % of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The damper opens during blower operation and closes when the blower is off. Adjustable blade stops allow different amounts of outside air to be introduced into the building and can be easily locked closed if required. Barometric Fresh Air Damper Motorized Fresh Air Damper BLANK OFF PLATE - BOP OPTIONAL A blank off plate is installed on the inside of the service door. It covers the air inlet openings, which restricts any outside air from entering the unit. The blank off plate should be utilized in applications where outside air is not required to be mixed with the conditioned air. MOTORIZED FREH AIR DAMPER - MFAD OPTIONAL The motorized fresh air damper is internally mounted behind the service door and allows outside ventilation air, up to % of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The two position damper can be fully open or closed. The damper blade is powered open by a VAC motor with spring return on power loss. The damper can be controlled by indoor blower operation or can be field connected to be managed based on building occupancy. NOTE: The above vent systems are intake only without built-in exhaust capability. Building will likely require separate field installed barometric relief or mechanical exhaust elsewhere within the conditioned space. Balancing dampers in the return air grille may be required to achieve specified amount of outdoor air intake. COMMERCIAL ROOM VENTILATOR - CRV OPTIONAL The built-in commercial room ventilator is internally mounted behind the service door and allows outside ventilation air, up to % of the total airflow rating of the unit, to be introduced through the air inlet openings. It includes a built-in exhaust air damper. Commercial Room Ventilator Economizer The commercial room ventilator (CRV) is a simple and innovative approach to improving the indoor air quality by providing fresh air intake and exhaust capability through the CRV. The damper can be easily adjusted to control the amount of fresh air supplied into the building. The CRV can be controlled by indoor blower operation or field controlled based on room occupancy. Two versions available (except on. and -Ton models). The CRV and CRV are power open - spring return on power loss, and CRVP is power open and power close. Complies with ANI/AHRAE tandard. Ventilation for Acceptable Indoor Air Quality. ECONOMIZER ECONWM-eries OPTIONAL The built-in economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. ECONWMT Equipment Building versions have extended " air intake hood to deliver up to % of cooling rated airflow. ECONWM tandard versions have 3" air intake hood to deliver up to % of cooling rated airflow. tandard Features: Fully modulating Honeywell Direct Drive Hi-Torque Actuator No linkage required imple single blade design Positive shut-off with non-stick gaskets Electronic DB and/or Enthalpy sensors depending upon version Honeywell JADE electronic economizer module with precision settings and diagnostics DB or Enthalpy economizer versions available WALL-MOUNT ENERGY RECOVERY VENTILATOR - ERVF OPTIONAL The wall-mount energy recovery ventilator (ERV) is a highly innovative approach to meeting indoor air quality ventilation requirements as established by ANI/AHRAE tandard.. The ERV allows from to CFM (depending upon model) of fresh air and exhaust through the unit while maintaining superior indoor comfort and humidity levels. In most cases this can be accomplished without increasing equipment sizing or operating costs. Heat transfer efficiency is up to 7% during summer and % during winter conditions. Energy Recovery Ventilator The ERV consists of a unique rotary energy recovery cassette that provides effective sensible and latent heat transfer capabilities during summer and winter conditions. Various control schemes are addressed including limiting ventilation during building occupancy only. The ERV is designed to be internally mounted behind the service door in the W**A or W**L model wall-mount units. It can be built-in at the factory (W**A only) or field installed as an option. ERVF-*3 and ERVF-* can be independently adjusted for intake and exhaust rates. Form No. 3-3 upersedes 3-3 Page 3 of

4 Commercial Room Ventilator Performance Data - CRV- W7/W & W TOTAL AND VENTILATION AIRFLOW 7 Total Air EP Total Air. EP Total Air.3 EP Vent Air EP Vent Air. EP Vent Air.3 EP 3 A B C D E F Vent Position Commercial Room Ventilator Performance Data - CRV-3 and CRVP-3 W3 & W3 HIGH PEED TOTAL AND VENTILATION AIRFLOW W3 & W3 LOW PEED TOTAL AND VENTILATION AIRFLOW 7 7 Total Air EP Total Air. EP Total Air.3 EP Vent Air EP Vent Air. EP Vent Air.3 EP Total Air EP Total Air. EP Total Air.3 EP Vent Air EP Vent Air. EP Vent Air.3 EP 3 3 A B C D E F Vent Position A B C D E F Vent Position Airflow (cfm) Airflow (cfm) Airflow (cfm) Form No. 3-3 upersedes 3-3 Page of

5 Commercial Room Ventilator Performance Data - CRV- and CRVP- Commercial Room Ventilator Performance Data - CRV- and CRVP W & W HIGH PEED TOTAL AND VENTILATION AIRFLOW W & W7 HIGH PEED TOTAL AND VENTILATION AIRFLOW Total Air EP Total Air. EP Total Air. EP Vent Air EP Vent Air. EP Vent Air. EP Total Air EP Total Air. EP Total Air. EP Vent Air EP Vent Air. EP Vent Air. EP Airflow (cfm) A B C D E F A B C D E F Vent Position W & W LOW PEED TOTAL AND VENTILATION AIRFLOW W & W7 LOW PEED TOTAL AND VENTILATION AIRFLOW Total Air EP Total Air. EP Total Air. EP Vent Air EP Vent Air. EP Vent Air. EP Airflow (cfm) Airflow (cfm) Vent Position 3 7 Total Air EP Total Air. EP Total Air. EP Vent Air EP Vent Air. EP Vent Air. EP Airflow (cfm) 3 3 A B C D E F A B C D E F Vent Position Vent Position Form No. 3-3 upersedes 3-3 Page of

6 Performance and Application Data- ERVF-A DB/ WB Ambient O.D. VENTILATION RATE -- CFM % EFFICIENCY UMMER COOLING PERFORMANCE (INDOOR DEIGN CONDITION DB/ WB) VENTILATION RATE -- CFM 3% EFFICIENCY VENTILATION RATE -- CFM 3% EFFICIENCY F VLT VL VLL HRT HR HRL VLT VL VLL HRT HR HRL VLT VL VLL HRT HR HRL Ambient O.D. ERVF-A WINTER HEATING PERFORMANCE (INDOOR DEIGN CONDITION 7 F DB) CFM 7% EFF. VENTILATION RATE CFM % EFF. CFM % EFF. DB/ F WVL WHR WVL WHR WVL WHR NOTE: ensible performance only is shown for winter application. LEGEND: VLT = Ventilation Load - Total VL = Ventilation Load - ensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HR = Heat Recovery - ensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery Form No. 3-3 upersedes 3-3 Page of

7 Performance and Application Data- ERVF-*3 Performance and Application Data- ERVF-* UMMER COOLING PERFORMANCE (INDOOR DEIGN CONDITION DB/ WB) UMMER COOLING PERFORMANCE (INDOOR DEIGN CONDITION DB/ WB) VENTILATION RATE -- CFM % EFFICIENCY VENTILATION RATE -- 3 CFM % EFFICIENCY VENTILATION RATE -- CFM 3% EFFICIENCY Ambient O.D. VENTILATION RATE -- CFM % EFFICIENCY VENTILATION RATE -- 3 CFM % EFFICIENCY VENTILATION RATE -- CFM 3% EFFICIENCY Ambient O.D. F VLT VL VLL HRT HR HRL VLT VL VLL HRT HR HRL VLT VL VLL HRT HR HRL DB/ WB F VLT VL VLL HRT HR HRL VLT VL VLL HRT HR HRL VLT VL VLL HRT HR HRL DB/ WB ERVF-* WINTER HEATING PERFORMANCE (INDOOR DEIGN CONDITION 7 F DB) ERVF-*3 WINTER HEATING PERFORMANCE (INDOOR DEIGN CONDITION 7 F DB) VENTILATION RATE VENTILATION RATE 3 CFM % EFFICIENCY 3 CFM % EFFICIENCY CFM % EFFICIENCY Ambient O.D. CFM 77% EFFICIENCY 3 CFM 7% EFFICIENCY CFM % EFFICIENCY Ambient O.D. DB/ F WVL WHR WVL WHR WVL WHR LEGEND: DB/ F WVL WHR WVL WHR WVL WHR 3 3 VLT = Ventilation Load - Total VL = Ventilation Load - ensible VLL = Ventilation Load - Latent HRT = Heat Recovery - Total HR = Heat Recovery - ensible HRL = Heat Recovery - Latent WVL = Winter Ventilation Load WHR = Winter Heat Recovery NOTE: ensible performance only is shown for winter application. NOTE: ensible performance only is shown for winter application. Form No. 3-3 upersedes 3-3 Page 7 of

8 Electrical pecifications W**A eries MODEL W7, A-A,AZ A A A WA-A, AZ A A A A WA-B, BZ B WA-C, CZ C W3A-A*, AZ* A* A A* A W3A-B*, BZ* B B* B W3A-C*, CZ* C C* C W3A-A*, AZ* A* A A* A W3A-B*, BZ* B* B* B W3A-C*, CZ* C* C* C WA-A, AZ A A A A WA-B, BZ B B B WA-C, CZ C C WA-A, AZ A A A A WA-B, BZ B B B WA-C, CZ C C WA-A, AZ A A A A WA-B, BZ B B B WA-C, CZ C C W7A-A, AZ A A A A W7A-B, BZ B B B W7A-C, CZ C C Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on C copper wire. All wiring must conform to the National Electrical Code and all local codes. These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. * Top outlet supply option is available only factory installed and only on the selected models. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor wires in accordance with the National Electrical Code and all local codes. Form No. 3-3 upersedes 3-3 Page of Rated Volts & Phase 3/- 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 No. Field Power Circuits or or or or or or or or or or Minimum Circuit Ampacity ingle Circuit Maximum External Fuse or Ckt. Brkr Field Power Wire ize 3 Ground Wire Minimum Circuit Ampacity Maximum External Fuse or Ckt. Breaker Dual Circuit Field Power Wire ize Ground Wire ize Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B

9 Electrical pecifications W**L eries MODEL W7, L-A,AZ A A A WL-A, AZ A A A WL-B, BZ B WL-C, CZ C W3L-A*, AZ* A* A A* A W3L-B*, BZ* B* B W3L-C*, CZ* C* C W3L-A*, AZ* A* A* A W3L-B*, BZ* B* B W3L-C*, CZ* C* C WL-A, AZ A A A WL-B, BZ B B WL-C, CZ C C WL-A, AZ A A A WL-B, BZ B B WL-C, CZ C C WL-A, AZ A A A WL-B, BZ B B WL-C, CZ C C W7L-AZ A A A W7L-BZ B B W7L-CZ C C Rated Volts & Phase 3/- 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 3/- 3/-3-3 No. Field Power Circuits or or or or or or Minimum Circuit Ampacity ingle Circuit Maximum External Fuse or Ckt. Brkr Field Power Wire ize 3 Ground Wire Minimum Circuit Ampacity Maximum External Fuse or Ckt. Breaker Dual Circuit Field Power Wire ize Maximum size of the time delay fuse or HACR type circuit breaker for protection of field wiring conductors. Based on C copper wire. All wiring must conform to the National Electrical Code and all local codes. These Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 3 for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table 3 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors are in a raceway. * Top outlet supply option is available only factory installed and only on the selected models. IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor wires in accordance with the National Electrical Code and all local codes. Ground Wire ize Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Ckt. A Ckt. B Form No. 3-3 upersedes 3-3 Page of

10 Indoor Blower Performance ( Hz) - CFM at Rated Volts peed W7/W W W3 W3 W/W W W7 High Low ingle High Low High Low High Low High Low High Low EP (Inch H) Above data is with " standard throwaway filter and " washable filter. For optional " pleated filter - reduce EP by. in. ee installation instructions for maximum EP information on various KW application. Factory Connected peed. Electric Heat Table - Refer to Electrical pecifications for Availability by Unit Model Nominal KW Kw At V () At V () At V () At V () -Ph Amps 3-Ph Amps Btuh Kw -Ph Amps 3-Ph Amps Btuh... 7, 3..,7...,7..,. 7.,7.., ,3.., , ,3.. 3,77..,...7 3, ,... 3., ,3.., ,.. 3.3, ,7..7,3..,.. 3.3,. 7., () These electric heaters are available in 3/V units only. () These electric heaters are available in V units only. Kw 3-Ph Amps Btuh Kw 3-Ph Amps Btuh Form No. 3-3 upersedes 3-3 Page of

11 Heater Packages - Field Installed "A" eries Right-Hand Units Designed for adding Electric Heat to KW Units Circuit Breaker tandard on 3/V Models Air Conditioner Models -A Models 3/- ETL U & Canada Listed Toggle Disconnect tandard on V Models -B Models 3/-3 -C Models -3 Heater Model # KW Heater Model # KW Heater Model # KW W7A WA EHWA-A EHWA-A EHWAA-A WA EHWAA-A EHWA-A EHWA-A EHWAA-A EHWA-B EHWHB-C W3A EHWA3-A EHWA3-A EHWA3-A EHWA3-A EHWA3-B EHWA3-B EHWA37-B EHWC3A-C EHWC3A-C EHWA3A-C EHWA3A-C W3A EHWA3-A EHWA3-A EHWA3-A EHWA3-A EHW3A-B EHWA3-B EHWA37-B EHWC3A-C EHWC3A-C EHWA3A-C EHWA3A-C WA WA EHWA-A EHWA-A EHWA-A EHWA-A EHWA-B EHWA-B EHWA-B EHWAA-C EHWAA-C WA EHWA-A EHWA-A EHWA-A EHWA-A EHWA-B EHWA-B EHWA-B EHWAA-C EHWAA-C W7A EHWA-A EHWA-A EHWA-A EHWA-A EHW7A-B EHWA-B EHW7A-B EHWAA-C EHWAA-C NOTE: Field installed Heater Packages are not approved for use with top supply opening models. Field installed Heater Package not available for W7L models. These heater packages approved for use in dehumidification versions with hot gas reheat. Heater Packages - Field Installed "L" eries Left-Hand Units Air Conditioner Models -A Models 3/- -B Models 3/-3 -C Models -3 Heater Model # KW Heater Model # KW Heater Model # KW W7L WL EHWAA-AL EHWA-AL EHWA-AL WL EHWAA-AL EHWA-AL EHWA-AL EHWA-BL W3L EHWA3-AL EHWA3-AL EHWA3-AL EHWA3-AL EHWA3-BL EHWA37-BL EHWC3-CL EHWA3-CL W3L EHWA3-AL EHWA3-AL EHWA3-AL EHWA3-BL EHWA37-BL EHWC3-CL EHWA3-CL WL WL EHWA-AL EHWA-AL EHWA-AL EHWA-BL EHWA-BL EHWAA-CL EHWAA-CL WL EHWA-AL EHWA-AL EHWA-AL EHWA-BL EHWA-BL EHWAA-CL EHWAA-CL W7L EHWA7-A EHWA-AL EHWA-AL EHW7A-BL EHWA-BL EHWAA-CL EHWAA-CL Form No. 3-3 upersedes 3-3 Page of

12 Clearances Required for ervice Access and Adequate Condenser Inlet Airflow MODEL LEFT IDE RIGHT IDE W7A, WA, WA, W3A, W3A " " WA, WA, WA, W7A " " NOTE: For side-by-side installation of two () WA models, there must be " between units. This can be reduced to " by using a WL model (left side compressor and controls) for the left unit and WA (right side compressor and controls) for right unit. Minimum Clearances Required to Combustible Materials MODEL UPPLY AIR DUCT FIRT THREE FEET CABINET W7A, WA, WA " " W3A, W3A /" " WA, WA, WA, W7A /" " Refer to the Installation Manual for more detailed information. Dimensions of W7-7A Basic Unit for Architectural & Installation Requirements (Nominal) MODEL W7A WA WA W3A W3A WA WA WA W7A WIDTH (W) DEPTH (D) HEIGHT (H) UPPLY RETURN A B C B E F G I J K L M N O P Q R T W Built In Rain Hood Pitch Heater Access Panel Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) Hood for ERV and ECONWM models only D A I ide Wall Mounting Brackets (Built In) Top Rain Flashing hipping Location E O 3. upply Air Opening B. R. F G Filter Access Panel Ventilation Air Condenser Air Outlet tandard flush vent door for non-erv/ Econ. models 3" " Low Voltage Hood for Electrical ECONWMT Entrance models. High Voltage Electrical Entrance Cond. Air Inlet J C H K Optional Electrical Entrances L M P Return Air Opening T Front View ide View Drain N Q Back View Bottom Installation Bracket MI-7 F Not used when ECONWMT Economizers installed. Filter access is through the ECONWMT hood. k Optional top outlet (factory installed only) for W3A and W3A models only. Form No. 3-3 upersedes 3-3 Page of

13 Clearances Required for ervice Access and Adequate Condenser Inlet Airflow MODEL LEFT IDE RIGHT IDE W7L, WL, WL, W3L, W3L " " WL, WL, WL, W7L " " NOTE: For side-by-side installation of two () WL models, there must be " between units. This can be reduced to " by using a WL model (left side compressor and controls) for the left unit and WA (right side compressor and controls) for right unit. Minimum Clearances Required to Combustible Materials MODEL UPPLY AIR DUCT FIRT THREE FEET CABINET W7L, WL, WL " " W3L, W3L /" " WL, WL, WL, W7L /" " Refer to the Installation Manual for more detailed information. Dimensions of W7-7A Basic Unit for Architectural & Installation Requirements (Nominal) MODEL W7L WL WL W3L W3L WL WL WL W7L WIDTH (W) DEPTH (D) HEIGHT (H) UPPLY RETURN A B C B E F G I J K L M N O P Q R T R Built In Electric E Rain Hood Heat Heater O Pitch Access. Panel D C. Breaker/ W.3 Disconnect upply Air Opening B ide Wall Mounting Brackets (Built In) Top Rain Flashing hipping Location A I Access Panel (Lockable) tandard flush vent door for non-erv/econ. models Hood used on ERV and ECONWM only Return Air Opening Optional Electrical Entrances C 3" Filter Access Panel Ventilation Air. F T Drain Bottom Installation Bracket Back View Q P M N L H K J Cond. Air Inlet ide View " Hood for ECONWMT models. Low Voltage Electrical Entrance High Voltage Electrical Entrance Condenser Air Outlet Front View G MI-3 A Not used when ECONWMT Economizers installed. Filter access is through the ECONWMT hood. Form No. 3-3 upersedes 3-3 Page 3 of

14 Cooling Application Data - Outdoor Temperature Model W7A W7L WA WL WA WL W3A W3L W3A W3L WA WL WA WL WA WL W7A W7L Return Air (DB/WB) / /7 /7 / /7 /7 / /7 /7 / /7 /7 / /7 /7 / /7 /7 / /7 /7 / /7 /7 / /7 /7 Cooling Capacity F F F F F F F F F F Below F (.3C), unit requires a factory or field installed low ambient control. Return air temperature Capacity Multiplier Factors % of Rated Airflow - Rated + Total BTUH... ensible BTUH... Form No. 3-3 upersedes 3-3 Page of

15 Air Conditioning Wall-Mount Model Nomenclature W 3 A A X X X X X X ERIE NOMINAL CAPACITY 7 - ½ Ton - ½ Ton - Ton 3 - ½ Ton 3-3 Ton - 3½ Ton - Ton - Ton 7 - Ton A = Compressor & Controls - Right ide L = Compressor & Controls - Left ide Ventilation Options REVIION VOLT & PHAE A - 3/// B - 3///3 C - //3 KW VENTILATION OPTION (ee Table Below) FILTER OPTION X - -inch Throwaway (tandard) W - -inch Washable P - -inch Pleated (MERV ) COLOR OPTION X - Beige (tandard) - White - Buckeye Gray - Desert Brown - Dark Bronze A - Aluminum - tainless teel For KW and circuit breakers (3/ Volt) or toggle disconnects ( Volt) applications, insert Z in the KW field of the model number. ee Pages & for available Factory Installed KW options and Page for Field Installed Heater Packages. Models W7A, WA, WA W3A, W3A WA, WA, WA, W7A W7L, WL, WL W3L, W3L WL, WL, WL, W7L Description Factory Installed Field Installed Factory Installed Field Installed Factory Installed Field Installed Code No. Part No. Code No. Part No. Code No. Part No. Barometric Fresh Air Damper - tandard X BFAD- X BFAD-3 X BFAD- Blank-Off Plate B BOP- B BOP-3 B BOP- Motorized Fresh Air Damper M MFAD- M MFAD-3 M MFAD- Commercial Ventilator - pring Return w/exhaust V CRV- V CRV-3 V CRV- Commercial Ventilator - Power Return w/exhaust P CRVP-3 P CRVP- Economizer - tandard Versions, Enthalpy m ECONWM-EB k ECONWM-E3B k ECONWM-EB k Economizer - Equipment Bldg., Enthalpy n W ECONWMT-EB k W ECONWMT-E3B k W ECONWMT-EB k Economizer - Equipment Bldg., DB Temp n T ECONWMT-TB k T ECONWMT-T3B k T ECONWMT-TB k Energy Recovery Ventilator - 3 Volt l R ERVF-A R ERVF-A3 j R ERVF-A j Energy Recovery Ventilator - Volt l ERVF-C o R ERVF-C3 j R ERVF-C j Door Kit for ERVF (Required) WMDK- l WMDK3- l WMDK- l Intake and exhaust can be independently adjusted. Insert color to match unit ("X" = Beige; "" = Buckeye Gray; etc.) WMDK Door Kit must be ordered in addition to ERVF Assembly & color matched to unit ("X" = Beige; "" = Buckeye Gray; etc.) Partial Full Flow (% of Rated Cooling CFM). All ECONWM versions have 3" deep intake hood. Full Flow (% of Rated Cooling CFM). All ECONWMT versions have " deep intake hood. Model WA-C & WL-C only. Energy Recovery Ventilator must be field-installed on W**L models. Also see Note. Air Conditioning Control Modules All Models Except As Noted W7A HPC LPC CCM LAC ALR K K ODT DDC Factory Installed Code Field Installed Part W7L Factory Only TD TD TD X TD TD TD E CMA- TD TD TD J Factory Only J TD TD TD K CMC- and CMA- TD TD TD M Factory Only M TD TD TD N, WA Only TD TD TD Field Installed Only CMC- CMC- TD TD TD Field Installed Only CMA- CONTROL MODULE (ee Chart Below) COIL OPTION X - tandard - Phenolic Coated Evaporator - Phenolic Coated Condenser 3 - Phenolic Coated Evaporator and Condenser UPPLY AIR OUTLET X - Front (tandard) T - Top (on W3A and W3A Models) TD TD TD V s Factory Only CMA-3 for W7-3 TD TD TD Field Installed Only CMA- for W-7 K Except W7 TD TD TD Field Installed Only K K W7 Only TD = tandard equipment for these specified models. HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. ee note. LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. ee note. CCM. Compressor control module has adjustable 3-second to -minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay-on-make will be - minutes plus % of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with retry) for high and/or low-pressure controls, and a -minute timed bypass for low-pressure control. LAC. Low ambient control permits cooling operation down to F. LAC is fan-cycling control for outdoor fan motor on all models except W/W Dehumidification units, which have modulating control. ALR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls. K. PTCR start kit can be used with all -A single phase models. Increases starting torque -3x. Not used for -B or -C three phase models. Do not use if K or K is used. K. tart capacitor and potential relay start kit can be used with all -A single phase models. Increases starting torque x. Not used for -B or -C three phase models. Do not use if CMC- is used. ODT. Outdoor thermostat is adjustable from to F. It is suitable for use as a compressor cut-off thermostat. DDC. Incorporates additional sensors: discharge air temperature, indoor blower airflow, compressor current, and dirty filter. These sensing devices function to input analog data such as temperature, as well as digital data such as airflow, compressor status or filter status. pecial economizer required; consult factory. V control module should be ordered in conjunction with direct digital controller (DDC) model TC. Refer to DDC specification sheet 3 for more information. Option not available for Model WA. Use option N for Alarm Relay on Model WA only. Form No. 3-3 upersedes 3-3 Page of

16 NOTE Bard Manufacturing Company, Inc. Bryan, Ohio ince... Moving ahead, just as planned. Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. 3 April, 3 upersedes: 3-3 Form No. 3-3 upersedes 3-3 Page of

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER - 9. EER, (HZ) Model W7A2 Right-ide Control Panel Model W7L2 Left-ide Control Panel Ton (, Btuh) For Export Only The Bard Wall-Mount Air Conditioner is a self contained energy

More information

THE WALL-MOUNT AIR CONDITIONERS (50HZ)

THE WALL-MOUNT AIR CONDITIONERS (50HZ) THE WALL-MOUNT AIR CONDITIONER (50HZ) Models W24A2 to W70A2 Right ide Control Panel Models W24L2 to W70L2 Left ide Control Panel 2,600 Btuh (6.33 KW) 62,000 Btuh (8.6 KW) For Export Only The Bard Wall-Mount

More information

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed. THE WALL-MOUNT AIR CONDITIONER -. EER, (HZ) Models WAA to W72AA Right-ide Control Panel Models WLA to W72LA Left-ide Control Panel. to Ton (7, to 7, Btuh) Green Refrigerant R-A The Bard Wall-Mount Air

More information

THE WALL-MOUNT Quiet Climate A/C 10.0 EER

THE WALL-MOUNT Quiet Climate A/C 10.0 EER THE WALL-MOUNT Quiet Climate A/C. EER Models WA, W9A, WA to Ton (, to, Btuh) Right Side Control Panel Hz GREEN REFRIGERANT R-A The Bard Wall-Mount Air Conditioner is a self contained energy efficient system,

More information

WALL-MOUNT HEAT PUMPS - (60HZ)

WALL-MOUNT HEAT PUMPS - (60HZ) WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to 5,000 Cooling Capacities:,00 to 5,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling

More information

THE WALL-MOUNT TM SIX TON AIR CONDITIONER

THE WALL-MOUNT TM SIX TON AIR CONDITIONER The Bard Wall-Mount Six Ton Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features THE WALL-MOUNT ONE TON AIR CONDITIONER W2AAA 2,000 Btuh.00 EER Right Side Control Panel 60Hz Green Refrigerant R-4A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A WALL-MOUNT HEAT PUMPS - (0HZ) Models: JH to J0H 0Hz Heating Capacities:,000 to,000 Capacities:,00 to,000 Solair Wall-Mount Heat Pump is a self-contained energy efficient heating and cooling system, which

More information

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS

THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS THE WALL-MOUNT QUIET CLIMATE HEAT PUMPS Models: SH to SH Up to.5 EER Heating Capacities: 2, to, BTUH Cooling Capacities: 2, to 55, BTUH Green Refrigerant R-A The Bard Wall-Mount Heat Pump is a self-contained

More information

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features

Green Refrigerant. THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 15.3 BTU/WATT. Engineered Features THE WALL-MOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To 5.3 BTU/WATT WA3S WA5S Right Side Control Panel WL3S WL5S Left Side Control Panel 3 to 5 Ton (35,2 to 5,5

More information

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models

THE WALL-MOUNT GAS/ELECTRIC Low NOx Certified Models Models: W24G3 to WG3 Up to 1.5 EER 26, to 57,5 BTUH Cooling Capacity 37, to 74, BTUH Heating Capacity The Bard Wall-Mount Electric Air Conditioner with gas fired heating is a self contained energy efficient

More information

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models

Green Refrigerant. MULTI-TEC WALL-MOUNT Features All Models. Standard Features All Models The MULTI-TEC Wall-Mount Air Conditioner utilizes PLC (Programmable Logic Control) technology to allow multiple units to operate connected to a single LC00 controller. When installed with an optional 0%

More information

THE WALL-MOUNT 6-TON AIR CONDITIONERS

THE WALL-MOUNT 6-TON AIR CONDITIONERS THE WLL-MOUNT -TON IR CONDITIONERS Model W7 - Right Side Control Panel Model W7L - Left Side Control Panel, Btuh 9.5 EER Hz The Bard Wall-Mount ir Conditioner is a self contained energy efficient system,

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WLL-MOUNT IR CONDITIONERS -. EER, (HZ) Models W7 to W. to Ton (, to, Btuh) Right Side Control Panel Hz The Bard Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed

More information

THE WALL-MOUNT HEAT PUMPS EER, (60HZ)

THE WALL-MOUNT HEAT PUMPS EER, (60HZ) THE WALL-MOUNT HEAT PUMPS -. EER, (HZ) Models: Heating Capacities: Cooling Capacities: Engineered Features WHA to WHA Hz (,5 to 5,5 Btuh) (7, to 5, Btuh) The Bard Wall-Mount Heat Pump is a self contained

More information

Q-TEC QC-Series Chilled Water Air Conditioner

Q-TEC QC-Series Chilled Water Air Conditioner Cooling Capacities: 13,3 to 49,3 BTUH (Based on EWT, GPM & CFM) Q-TEC QC-Series Chilled Water Air Conditioner The Q-TEC Series self-contained packaged chilled water air conditioner is designed to be installed

More information

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT NOx Certified Models WG3S2, WG4S2, WG5S2 6HZ 24, to 56,5 BTUH Cooling Capacity 37,

More information

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit D35A/L 1-tage Right & Left-Hand Control Panel The Bard DUAL-TEC Wall Mount Air Conditioners with -48VDC Blower

More information

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit

DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit DUAL-TEC WALL-MOUNT Air Conditioners with -48VDC Blower Motor DC Voltage 100% Free Cooling Unit D36A/L 1-tage Right & Left-Hand Control Panel Green Refrigerant R-410A The Bard DUAL-TEC Wall Mount Air Conditioners

More information

Q-Tec TM QC-Series Chilled Water Air Conditioner

Q-Tec TM QC-Series Chilled Water Air Conditioner Q-Tec TM QC-Series Chilled Water Air Conditioner Cooling Capacities:, to, BTUH (Based on EWT, GPM and ) The Q-Tec Series self-contained packaged chilled water air conditioner is designed to be installed

More information

THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD

THE MULTI-TEC WALL-MOUNT AIR CONDITIONERS 10 EER (50 HZ) WITH LOGIC BOARD The MULTI-TEC Wall-Mount Air Conditioner utilizes PLC (Programmable Logic Control) technology to allow multiple units to operate connected to a single LC6000 controller. When installed with an optional

More information

Q-TEC Q24A-Q60A Air Conditioners

Q-TEC Q24A-Q60A Air Conditioners The Q-TEC Series self contained packaged air conditioner is designed to be installed inside a building structure against an exterior exposed wall. Q-TEC s design provides whisper quiet operation with total

More information

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units

Q-TEC Q24H3-Q60H3 Air-to-Air Heat Pump 10 EER Units Heating Capacities: Cooling Capacities: Q-TEC Q2H3-QH3 Air-to-Air Heat Pump 0 EER Units 23,0 to,000 Btuh,000 to 5,0 Btuh The Q-TEC Series self contained packaged heat pump is designed to be installed inside

More information

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant

The Wall-Mount Variable Capacity Environmental Control Units. Green Refrigerant The Wall-Mount Variable Environmental Control Units Bard is an ISO 00:200 Certified Manufacturer, 5 and -Ton Variable ECU Dual /50 Hz Frequency Cooling Op Range -40F to +F ODT The Bard Variable ECU design

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A THE WALLMOUNT STEP CAPACITY AIR CONDITIONERS Integrated Part Load Value (IPLV) Efficiency Up To. BTU/WATT WAS, WAS, WAS to Ton (,0 to,00 Btuh) Right Side Control Panel 0Hz GREEN REFRIGERANT RA The Bard

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGED AIR CONDITIONER Models: W7A2-A WA2-A W24A2-A W24A2-B W24A2-C W24A2-D W24A2-F WA2-A WA2-B WA2-C WA2-D WA2-F WA2-A WA2-B WA2-C WA2-D WA2-E WA2-F W42A2-A W42A2-B

More information

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps

Q/Tec TM QH-Series 2 Air-to-Air Heat Pumps Heating Capacities: 2, to 7, BTUH Capacities:, to 2, BTUH The Q/Tec Series self-contained packaged heat pump is designed to be installed inside a building structure against an exterior exposed wall. Q/Tec

More information

Q/Tec TM QA-Series Air Conditioners

Q/Tec TM QA-Series Air Conditioners Q/Tec TM QASeries Air Conditioners The Q/Tec series self contained packaged air conditioner is designed to be installed inside a building structure against an exterior exposed wall. Q/Tec s design provides

More information

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB

BARD MANUFACTURING COMPANY, INC. W18AA-W72AB BARD MANUFACTURING COMPANY, INC. W18AA-W72AB Series Right-Side Access Air Conditioner W18LA-W72LB Series Left-Side Access Air Conditioner Engineering Specification Guide 1.0 GENERAL Furnish and install

More information

GREEN REFRIGERANT R-410A

GREEN REFRIGERANT R-410A PH-SERIES PCKGED HET PUMPS Cooling Capacities: 2, to 6, Heating Capacities:, to 2, SEER:. HSPF: GREEN REFRIGERNT R-4 FRONT (INDOOR IRFLOW) END OF UNIT CK (OUTDOOR IRFLOW) END OF UNIT Standard Engineered

More information

1.5 to 3 Ton 208V to 460V 60hz Air Conditioner Specifications

1.5 to 3 Ton 208V to 460V 60hz Air Conditioner Specifications .5 to 3 Ton 2V to 4V hz Air Conditioner Specifications EER WA Series WALL-MOUNT.5 to 3 Ton V to 4V EER hz AirWA Conditioner Specifications. TM Series WALL-MOUNT Wall-Mount Air Conditioner is a self nergy

More information

Installation Instructions

Installation Instructions Installation Instructions Wall Mounted Packaged Air Conditioner Models: WA8, WA24 MIS-656 Bard Manufacturing Company Bryan, Ohio 43506 Since 94...Moving ahead, just as planned. Manual No.: 20-200K Supersedes:

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS WA3 WA43 WA44 WA49 WA Bard Manufacturing Company Bryan, Ohio 4350 Since 94...Moving ahead just as planned. Manual : 0-39 Supersedes:

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS WA3 WA42 WA42 WA49 WA2 Bard Manufacturing Company Bryan, Ohio 4350 Since 94...Moving ahead just as planned. Manual : 20-2J Supersedes:

More information

Q/Tec TM QW-Series Water-to-Air Heat Pumps

Q/Tec TM QW-Series Water-to-Air Heat Pumps Heating Capacities: 6,4 to 45,5 BTUH Capacities:, to 53,5 BTUH : 3. to 3.5 : 3.4 to 6.6 Q/Tec TM QW-Series Water-to-Air Heat Pumps The Q/Tec series self contained packaged water-to-air heat pump is designed

More information

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS J7A2 J7L2 J24A2 J24L2 JA2 JL2 J3A2 J3L2 J42A2 J42L2 J4A2 J4L2 JA2 JL2 J70A2 J70L2 Manual : 0-5A Supersedes: 0-5 File: Volume III Tab

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: WA121 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-234 G Supersedes: 2100-234

More information

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide 1.0 GENERAL Furnish and install a self-contained, vertical, exterior wall mount, electric air conditioner

More information

Product Guide. Wallmount. Air Conditioners & Heat Pumps

Product Guide. Wallmount. Air Conditioners & Heat Pumps Product Guide Wallmount Air Conditioners & Heat Pumps Standard Features page 2 All Major Components can be Accessed from the Front 00 Hour Salt Spray rated powder coated baked paint finish AHRI certified

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS W18H1 W24H1 W30H1 W36H1 W42H1 W48H1 W60H1

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS W18H1 W24H1 W30H1 W36H1 W42H1 W48H1 W60H1 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS WH W24H WH W3H W42H W4H W0H Bard Manufacturing Company, Inc. Bryan, Ohio 43 Since 94...Moving ahead just as planned. Manual : 20-5B Supersedes:

More information

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Wall Mounted Air Conditioners with Gas Heat Models AVGA PRODUCT DATA SHEET Wall Mounted Air Conditioners with Gas Heat Models AVGA24-30-36-42-48-60 General Description The Marvair GPac wall mounted air conditioner with gas heat is designed for use on a variety

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS W12A2-A W12A1-K INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: W12A2-A W12A1-K Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual: 2100-509E Supersedes:

More information

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES 180-300 INGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNIT 15-25 NOMINAL TON ubmittal Data DECRIPTION The units are one -piece electric cooling/optional electric heating units, prewired and precharged.

More information

I-TEC I30A1D-I60A1D 2-Stage Compressor High Efficiency Air Source Air Conditioners w/dehumidification

I-TEC I30A1D-I60A1D 2-Stage Compressor High Efficiency Air Source Air Conditioners w/dehumidification I-TEC I30AD-IAD 2-Stage Compressor High Efficiency Air Source Air Conditioners w/dehumidification Cooling Capacities: 20,0 to 54,000 Btuh The Bard I-TEC Air Conditioner system is designed for classrooms

More information

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3 WGERV-C3 WGERV-A5 WGERV-C5 BARD MANUFACTURING COMPANY Bryan, Ohio 4356 Since 1914...Moving ahead, just as planned. Manual:

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP Models WH84 WH242 Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 94...Moving ahead just as planned. Manual : 200-423C Supersedes: 200-423B

More information

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA PRODUCT DATA SHEET 1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac air conditioner is a cost-effective vertical, wall mounted air

More information

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners PRODUCT DATA SHEET 9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Eubank WalPac A/C 9 air conditioner is a cost-effective vertical,

More information

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR INSTALLATION INSTRUCTIONS Models: ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR For Use with Bard 2 Thru 5 Ton "P" Series Air Conditioners and Heat Pumps Bard Manufacturing Company, Inc. Bryan,

More information

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA24-30-36-42-49-60 and HVPSA36-42-49-60 General Description HIGH EFFICIENCY - The Marvair Classic 13 High Efficiency Series

More information

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: 90-007 QWSERV 90-08 QWSERV with Intelligent Defrost For Use With Bard Through 5 Ton QW*S Series Bard Manufacturing Company, Inc. Bryan,

More information

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: 90-09 QWSERV with Occupied Air Capabilities For Use With Bard Through Ton QW*S Series Bard Manufacturing Company, Inc. Bryan, Ohio

More information

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP

ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS ComPac I & ComPac II 1 to 6 Ton Vertical Wall Mount Air Conditioners Models AVP12-20-24-30-36-42-48-60-72 General

More information

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH R EQUIPMENT ARI STANDARD 210 ARI STANDARDS GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP24-30-36-42-48-60 General Description The Marvair

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH421 WH483 WH602

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH421 WH483 WH602 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS: WH42 WH43 WH2 BARD MANUFACTURING COMPANY Bryan, Ohio 4350 Since 94...Moving ahead, just as planned. Manual: 20-399 Supersedes: File: Volume

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP WH184 WH242 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMP Models WH184 WH242 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-423A Supersedes: 2100-423

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL-MOUNTED PACKAGED AIR CONDITIONER HA-A HL-A Models: H6A-A H6L-A Description Page Cabinet Components HA-A, H6A-A Exploded View... Usage List HA-A... Usage List H6A-A... Cabinet

More information

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Fig. 1 - Unit 50VR -A 50VR---A Performancet 15 SEER 2---Stage Packaged Heat Pump tem with PuronR (R---410A) Refrigerant Single and Three Phase 2to5NominalTons(Sizes24---60) Product Data Fig. 1 - Unit 50VR -A A09033 Single-Packaged

More information

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5 INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5 Bard Manufacturing Company, Inc. Bryan, Ohio 4356 Since 1914...Moving

More information

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: WERV-A5 WERV-C5 For Use with Bard 3-1/2 Through 5 Ton Wall Mount Air Conditioners and Heat Pumps Bard Manufacturing

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS MODELS: WH422D WH44D WH3D Bard Manufacturing Company Bryan, Ohio 43506 Since 94...Moving ahead just as planned. Manual : 20-443 Supersedes: File:

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH381 WH431 WH491

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS WH381 WH431 WH491 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS Models WH3 WH43 WH49 Bard Manufacturing Company, Inc. Bryan, Ohio 436 Since 94...Moving ahead just as planned. Manual : 20-342I Supersedes: 20-342H

More information

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: WERV-A2B WERV-A3C WERV-C2B WERV-C3C For Use With Bard 1-1/2 Through 3 Ton Wall Mount Air Conditioners and Heat Pumps

More information

BARD FUSION-TEC TM WALL-MOUNT TM Free Cooling Economizer and Air Conditioner

BARD FUSION-TEC TM WALL-MOUNT TM Free Cooling Economizer and Air Conditioner BARD FUSION-TEC TM WALL-MOUNT TM Free Cooling Economizer and Air Conditioner Bard High Sensible Cooling Systems HR36 Series 12.5 EER 2 to 3 Ton HR58 Series 11.0 EER 3.5 to 5 Ton The FUSION-TEC TM has been

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV. Bard Manufacturing Company, Inc.

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV. Bard Manufacturing Company, Inc. INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV Bard Manufacturing Company, Inc. Bryan, Ohio 4356 Since 1914...Moving ahead, just as planned. Manual: 21-495 Supersedes:

More information

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons Product Data 50HS Single-Package Heat Pumps 1 1 2 to 5 Nominal Tons Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece heat pumps with optional

More information

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: ERVF-A2 ERVF-C2 For Use With Bard 1-1/2 Through 2 Ton Wall Mount Air Conditioners and Heat Pumps Bard Manufacturing

More information

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: ERVF-A3 ERVF-C3 For Use With Bard 2-1/2 through 3 Ton Wall Mount Air Conditioners and Heat Pumps Bard Manufacturing

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WALL-MOUNTED VARIABLE CAPACITY ENVIRONMENTAL CONTROL UNIT Models: W3RV2-R W3RV2-S W3RV2-T W3LV2-R W3LV2-S W3LV2-T W5RV2-R W5RV2-S W5RV2-T W5LV2-R W5LV2-S W5LV2-T W6RV2-S W6RV2-T

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS & LOW VOLTAGE CONTROL CIRCUIT WIRING MODELS J18H2 J24H2 J30H2 J36H2 J42H2 J48H2 J60H2

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS & LOW VOLTAGE CONTROL CIRCUIT WIRING MODELS J18H2 J24H2 J30H2 J36H2 J42H2 J48H2 J60H2 INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE HEAT PUMPS & LOW VOLTAGE CONTROL CIRCUIT WIRING MODELS JH2 J24H2 JH2 J3H2 J42H2 J4H2 JH2 Manual: 200- Supersedes: NEW File: Volume III, Tab 7 Date: -25-3

More information

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST Models: WERV-A5 WERV-C5 For Use With Bard 3-1/2 through 5 Ton Wall Mount Air Conditioners and Heat Pumps Bard Manufacturing

More information

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS MODELS W3A W49A WA Bard Manufacturing Company, Inc. Bryan, Ohio 4350 Since 94...Moving ahead just as planned. Manual : 20-530A Supersedes:

More information

PAR5. Product Specifications

PAR5. Product Specifications TM PAR5 Product Specifications UP to 16 SEER, UP to 12.5 EER, PACKAGE AIR CONDITIONING UNITS, 2 5 TONS 208/230 Volt, 1 phase, 60 Hz 208/230 Volt, 3 phase, 60 Hz REFRIGERATION CIRCUIT Environmentally balanced

More information

Models: Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel. Blower Assembly

Models: Contents. Cabinet Components. Functional Components  Exploded View... 3  Usage List Control Panel. Blower Assembly REPLACEMENT PART MANUAL WALL MOUNTED PACKAGE AIR CONDITIONER Models: WA0, WA7 General Notes! Revised and/or additional pages may be issued from time to time.! A complete and current manual consists of

More information

48PGD/E/F/L/M/N PG20-28

48PGD/E/F/L/M/N PG20-28 48/50PG-10SB 48PGD/E/F/L/M/N20-28 50PG20-28 SINGLE-PACKAGE COOLING UNITS WITH FACTORY-INSTALLED GAS HEAT SINGLE-PACKAGE COOLING UNITS WITH OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving Product Data ROOMTOP 50AH024-096 Standard Efficiency Horizontal Indoor Single-Package Cooling Units with PURON Refrigerant (R-410A) 2 to 8 Nominal Tons The 50AH single-package cooling units feature: ASHRAE

More information

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER DCC Series Submittal Data Form Job Name Purchaser Order No. Engineer Unit No. Model No. Unit Designation Performance Data Certified By: 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

More information

RGE 13 A T - 1 A

RGE 13 A T - 1 A PRODUCT SPECIFICATIONS PACKAGED GAS / ELECTRIC 3GEP / RGE3 Rooftop Units 60HZ Bulletin No. 2063 December 202 Supersedes October 202 MODEL NUMBER IDENTIFICATION -PHASE MODELS SEER - 3.00 (3GEP Shown) AFUE

More information

General Description. Operation

General Description. Operation ECUA12ACA & ECUA18ACA SlimPac (1 & 1.5 Ton) Environmental Control Units General Description The Industrial Climate Engineering SlimPac line of Environmental Control Units (ECU) are designed for the telecommunication

More information

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A GEOTEC GV Series High Efficiency Geothermal/Water Source Packaged Step- Heat Pump R-410A Ground Water Application: Water Temp 45 to 75 Ground Loop Application: Temp Range to 110 The Bard GEOTEC Geothermal/Water

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGED AIR CONDITIONER Models: WAA-A W2AA-A W2AA-B W2AA-C W2AA-D W2AA-F WAA-A WAA-B WAA-C WAA-D WAA-F W3AA-A W3AA-B W3AA-C W3AA-D W3AA-E W3AA-F W2AA-A W2AA-B W2AA-C

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

62DA,DB,DC,DD,DE,DF07-38

62DA,DB,DC,DD,DE,DF07-38 62D-3SB 62DA,DB,DC,DD,DE,DF07-38 DEDICATED VERTICAL OR HORIZONTAL 100% OUTDOOR AIR UNIT PERFORMANCE DATA UNIT DIMENSION PRINTS ACCESSORY DIMENSION PRINTS Copyright 2011 Carrier Corporation Syracuse, New

More information

PAJ3. Product Specifications

PAJ3. Product Specifications 13 SEER, R 410A PACKAGE AIR CONDITIONER FOR MANUFACTURED HOUSING, RESIDENTIAL, AND LIGHT COMMERCIAL APPLICATIONS 2 5 TONS Single Phase, 208/230 V, 60 Hz BUILT TO LAST, EASY TO INSTALL AND SERVICE Compact,

More information

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL REPLACEMENT PARTS MANUAL WALL-MOUNTED PACKAGE AIR CONDITIONER Models: W7A W8A WA General Notes Revised and/or additional pages may be issued from time to time. A complete and current manual consists of

More information

General Description. Safety Listed

General Description. Safety Listed ECUA90/120/150/180/240 & ECUDA180/240/300/360 (7.5, 10, 12.5, 15, 20, 25 & 30 Ton) Vertical Wall Mount Air Conditioners General Description Industrial Climate Engineering s air conditioners are used primarily

More information

General Description. Safety Listed

General Description. Safety Listed ECUA90/120/150/180/240 & ECUDA180/240/300/360 (7.5, 10, 12.5, 15, 20, 25 & 30 Ton) Vertical Wall Mount Air Conditioners General Description Industrial Climate Engineering s air conditioners are used primarily

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners

MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners MEGA-TEC TM 10EER 10 Ton Capacity Air Conditioners Bard Manufacturing's revolutionary MEGA-TEC WALL-MOUNT sets the industry standard for flexibility. Engineered to cool virtually any equipment building

More information

THE WALL-MOUNT TM QUIET CLIMATE HEAT PUMPS

THE WALL-MOUNT TM QUIET CLIMATE HEAT PUMPS THE WLL-MOUNT TM QUIET LIMTE HET PUMPS Models: S26H to S6H EER Heating apacities: 2, to, TUH ooling apacities: 2, to, TUH GREEN REFRIGERNT R-4 The ard Wall-Mount Heat Pump is a self-contained energy efficient

More information

GreenPac & GreenPac HGR Air Conditioners Single stage models AVPA and HVEA and 2-stage models HVESA

GreenPac & GreenPac HGR Air Conditioners Single stage models AVPA and HVEA and 2-stage models HVESA General Description The Marvair GreenPac and GreenPac HGR (Hot Gas Reheat) air conditioners are complete, factory assembled wall-mounted systems designed to provide total comfort while meeting ventilation

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION

More information

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT PGF SERIES 7-1/2 Ton C Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT SINGLE PACKAGE Combination gas heating and electric cooling, self contained for year-round comfort. Systems can be installed

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-193 REV. 3 Supersedes Form No. A22-193 Rev. 2 Commercial High-Efficiency Condensing Units 15 & 20 TON MODEL [52.8 & 70.3 kw] 10 & 12.5 TON MODEL [35.2 & 44.0 kw] 10 THROUGH 20 NOMINAL TON

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information