VULCAN AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION

Size: px
Start display at page:

Download "VULCAN AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION"

Transcription

1 VULCAN AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION Operation only in heating Operation up to -18 C Reduced energy consumption Water production from 60 C to -10 C external air *Due to its high efficiency, "Vulcan'" may be eligible for heat pump subsidies in Your Country. Please contact Your tax office or utility. WBAN (R-407C) Size Heating [kw] 41 14, , ,3 REPLACE: BT05I016GB-09 The heating of the future respects the environment. The VULCAN heat pump series represent an important stage in the development of this type of unit. They feature the most up-to-date advances in technology, standing out for: EFFICIENCY thanks to its special construction, the WBAN series ensures high energy efficiency also in extreme working conditions; SELF-ADAPTING the evolved electronics implemented adapt the operating parameters of the chiller to the load conditions of the system it is installed in, optimising consumption, noise and the working life of the components; EASE OF INSTALLATION each unit is supplied as standard with a complete hydronic assembly and is completely tested in the factory; installation is consequently quick and easy. CERTIFIED QUALITY SYSTEM UNI EN ISO 9001:2008 According to the UNI EN 14511:2008

2 PERFECT FOR RESIDENTIAL EUROVENT ENERGY EFFICIENCY CLASSIFICATON CLASS A IN HEATING MODE PERFECT FOR HEATING AND UNDERFLOOR HEATING Thanks to its characteristics the unit can be used both in traditional systems with TERMINAL UNITS and in systems with EMBEDDED UNDERFLOOR PIPING with higher efficiency than traditional units. TOP NOISELESSNESS FOR A SUPERIOR COMFORT EUROVENT ENERGY EFFICIENCY CLASSES WATER: 30/35 C AIR 7 C D.B. / 6 C W.B. Noise is one of the most critical factors of this type of unit. The application of special regulation logic enables to adapt the fan operating speed to the system load and to the external air temperature. In this way you can optimize the energy efficiency and guarantee the lowest possible noise level, especially during evening and night hours, when the air temperature is lower and sensitivity to noise is greater. WATER FILTER - SUPPLIED AS STANDARD (external installation) Steel mesh mechanical filter positioned at the exchanger inlet. Suitable for filtering water and trapping the impurities present in the water circuit. ICE PROTECTION SYSTEM A special measure in the refrigerating circuit prevents ice from forming in the base of the air exchanger. STANDARD-SUPPLIED USER KEYPAD The remote keyboard allows unit start and stop, Summer/Winter setting, 2 selections of ambient temperature, one of "COMFORT" temperature where the set point is visualized only on board, an other of "ECO" temperature that decreases in winter mode and increases in summer mode the set point and the hidric /cooling/electric circuit alarm signal. The connection is done with a shielded cable 3 x 0.34mm2 max 100m which is connected with the unit. Thanks to its pleasant aspect it can be installed in ambient. Electric - refrigerating - water alarm signals Check comfort-economic-test control SUMMER-WINTER-OFF signals SUMMER-WINTER-OFF control 2

3 STANDARD UNIT SPECIFICATIONS COMPRESSOR Hermetic orbiting scroll compressor complete with motor over-temperature and over-current devices and protection against excessive gas discharge temperature. Fitted on rubber antivibration mounts and complete with oil charge. A oil heater is automatically switched on at the compressor shut-down to prevent oil dilution by the refrigerant. STRUCTURE Structure made from "aluzink" plate, providing excellent mechanical characteristics and extensive corrosion strength PANELLING External panels in prepainted aluminium especially indicated in outdoor installation due to its superior resistance to corrosion avoiding periodic painting. Side panels are easily removable and allow complete access to unit components. Internal sound proof lining reduces sound pressure levels. INTERNAL EXCHANGER Direct expansion heat exchanger, braze-welded AISI 316 stainless steel plates with large exchange surface and complete with external heat and anti-condensate insulation. The exchanger comes complete with: - antifreeze heater to protect the water side exchanger, preventing the formation of frost if the water temperature falls below a set value. EXTERNAL EXCHANGER Heat exchange coil with aluminium fins and copper tubes in staggered rows. The coils are complete with integral subcooling circuit which assures the correct refrigerant feeding of the expansion valve. Available in different options as per optional list. The unit is fitted as standard with coil protection grills. FAN Propeller fans with aluminium pressure die-cast blades, directly driven by single-phase external rotor electric motor complying with VDE 0530/12.84, complete with thermal protection, IP 54 class according to DIN norm. The impellers are housed in aerodynamically shaped nozzles to increase the efficiency and minimize the sound level, and protected by fan guards. REFRIGERANT CIRCUIT The circuit is complete with: - filter dryer - expansion device - high pressure switch - low pressure switch - liquid receiver - 4-way reverse cycle valve - Ice Protection System: system to prevent ice on the bottom of air coil TRAY Thermoformed ABS condensate collection tray fitted with drain pipe. ELECTRICAL PANEL The Power Section includes: - compressor and fan fuses only on unit 230/1/50 - compressor circuit breaker only on unit 400/3/50 - compressor control contactor - main door lock isolator switch - In sizes /1/50, the soft starter is included standard. The control section includes: - microprocessor control - variable fan speed control for operation at low ambient temperatures - automatic defrost control - set point compensation with outside temperature probe - set point compensation with 4-20 ma signal - high refrigerant gas pressure pre-alarm function that in many cases prevents the unit from being shut-down - compressor overload protection and timer - relay for remote cumulative fault signal - management of electrical heating elements - double temperature management - domestic water valve control - electronic for Elfo Control system (optional) REMOTE KEYPAD FOR USER remotable control keypad, including: - SLEEP button for optimised night-time operation - ON/OFF and alarm reset buttons - signal led electric circuit alarm - signal led refrigerant circuit alarm - hydraulic circuit alarm signal led The remote keypad connection for user to the unit is set using a 3 x 0.34 mm 2 screened cable. Maximum distance 100m. HYDRAULIC CIRCUIT - stainless steel mesh mechanical filter. - centrifugal pump - diaphragm expansion vessel - water side safety valve - water fill assembly with pressure gauge - drain valve - differential pressure switch, water side ACCESSORIES SYSTEM ACCESSORIES - 00 litres hydraulic breaker - hose kit for connection to chiller/heat pump. With connections of 1" - hose kit for connection to chiller/heat pump. With connections of 1 1/4" - radiant panels management kit with 1" connections - Kit for management of radiant panels with connections of 1 1/4" litres domestic hot water kit - boiler control kit - electronic wall-mounting room thermostat ACCESSORIES SEPARATELY PROVIDED: - rubber antivibration mounts - domestic hot water kit control - serial communication module to supervisor (MODBUS) - phase monitor - local control portable keypad with cable 1,5 metres CONFIGURATION CODE ( 1 ) ( 2 ) ( 3 ) ( 4 ) ( 5 ) ( 6 ) WBAN TN CCS - HYGU - - (1) VOLTAGE Supply voltage 400/3/50+N(400TN) 400TN = 400/3/50+N Supply voltage 230/1/50(230M) only size 41 (2) ENERGY EFFICIENCY High Energy efficiency TN CCS (Standard) - (Standard) HY GU (St andard) - (Standard) - (Standard) M CCCA EH246-3WV SFSTR4N 81 CCCA1 CCCC (3) CONDENSING COIL Standard condenser coil (CCS) standard Copper / aluminium condenser coil with acrylic lining (CCCA) Copper / aluminium condenser coil with Fin Guard treatment (Silver) (CCCA1) Copper /copper condenser coil (CCCC) (4) AUXILIARY ELECTRIC HEATING ELEMENTS Integration heating elements: not required (-) standard Modular integration electric heater 2-4 and 6kW (EH246) (5) HYDRONIC GROUP UTILITY SIDE Hydronic group utility side (HYGU) standard Hydronic group utility side: not required (-) (6) 3-WAY VALVE Three-way valve: not required(-) standard Three-way valve (3WV) for sanitary hot water (7) SOFT STARTER Disposal for inrush current reduction: not required (-) standard Disposal for inrush current reduction, for unit 400/3/50+N(SFSTR4N) Disposal for inrush current reduction, for unit 400/3/50+N In sizes 41, 230/1/50, the soft starter is included standard. 3

4 GENERAL TECHNICAL SPECIFICATIONS Size HEATING Heat output (40/45 C _ 7 C D.B. / 6 C W.B.) 1 kw 14,9 19,3 26,0 Compressor power input (40/45 C - 7 C D.B. / 6 C W.B.) 1 kw 3,99 5,37 7,27 Total power input 2 kw 4,51 5, COP(Eurovent 40/45 C_ 7 C D.B. / 6 C W.B.) 1 3,45 3,39 3,32 COP (UNI EN 14511:2008; 30/35 C _7 C D.B. / 6 C W.B.) HIGH EFFICIENCY 3 4,10 4,14 4,10 COMPRESSOR Type of compressors SCROLL SCROLL SCROLL No. of Compressors Nr Std Capacity control steps Nr Oil charge (C1) l 1,4 1,7 4 Refrigerant charge (C1) kg 4 4,2 5,5 Refrigerant circuits Nr INTERNAL EXCHANGER Type of internal exchanger 4 PHE PHE PHE No. of internal exchangers Nr Water flow rate (Internal Exchanger) 1 l/s 0,71 0,92 1,21 Useful pump discharge head 1 kpa Water content l 2 2,2 2,7 EXTERNAL SECTION FANS Type of fans 5 AX AX AX Number of fans Nr Standard air flow l/s Installed unit power kw 0,16 0,16 0,16 CONNECTIONS Water fittings 1"GAS F 1"GAS F 1"GAS F HYDRAULIC CIRCUIT Max water side pressure kpa Safety valve calibration kpa EXPANSION VESSEL Expansion vessel capacity l Maximum water side pressure kpa Nitrogen buffer pressure kpa No. of expansion vessels Nr POWER SUPPLY Standard power supply V 230/1/50 400/3/50+N 400/3/50+N NOISE LEVELS Sound pressure level (1 m) db(a) DIMENSIONS Length mm Depth mm Height mm Packing volume m3 0,9 0,9 1,4 STANDARD UNIT WEIGHTS Shipping weight kg Operating weight kg Shown data are referred to units working in perfect installation and exchangers' cleaning conditions. (1) Data referred to the following conditions : - outlet water internal exchanger 45 C - outdoor air temperature 7 C DB - 6 C WB DT=difference between inlet/outlet water temperature = 5 C (2) Total input is obtained from compressor input + fan input (3) The indicated COP values were calculated in compliance with the provisions of standard EN :2008. (4) PHE = plates (5) AX = axial-flow fan (6) The size 41 is available with supply voltage 400/3/50 + N 4

5 OPERATING LIMITS (HEATING) EXTERNAL EXCHANGER Max air temperature inlet (WB) 1 C Min air inlet temperature (W.B.) 2 C INTERNAL EXCHANGER Min. water outlet temperature 3 C Max water outlet temperature 4 C Water thermal head (min / max) C 3 / 8 3 / 8 3 / 8 ATTENTION: IN CASE OF PREDOMINANT WINDS, WINDBREAK BARRIERS ARE NECESSARY. Shown datas are referred to units working in perfect installation and exchangers' cleaning conditions. (1) water to internal exchanger 41/46 C summer operation, with fan speed control device (2) water to internal exchanger */55 C (3) outdoor air temperature 7 C DB - 6 C WB (4) Outdoor air temperature: -10 C D.B./ C W.B Tw [ C] = HEAT EXCHANGER OUTLET WATER TEMPERATURE Ta = OUTSIDE AIR TEMPERATURE ( C) W.B. (1) THE SHADED AREA SHOWS OPERATION WITH AIR FLOW RATE IN MODULATION Tw ( C) ( 1 ) Ta ( C) ELECTRICAL DATA VOLTAGE: 230/1/50 Size 41 F.L.A. - FULL LOAD CURRENT AT MAX ADMISSIBLE CONDITIONS F.L.A. - Circulator A 1,2 F.L.A. - Total A 30.5 F.L.I. FULL LOAD POWER INPUT AT MAX ADMISSIBLE CONDITION F.L.I. - Circulator kw 0,3 F.L.I. - Total kw 6.2 M.I.C. MAXIMUM INRUSH CURRENT M.I.C. - Value A 45 Power supply 230/1/50 Hz +/-6% Voltage unbalance: max 2 % The circulator is included in the total values calculation The units are compliant with the provisions of European standards CEI EN and CEI EN In case of abnormal conditions, the device does not limit the current, providing the torque necessary at the compressor starting.. ELECTRICAL DATA VOLTAGE: 400/3/50+N Size F.L.A. - FULL LOAD CURRENT AT MAX ADMISSIBLE CONDITIONS F.L.A. - Circulator A 1,2 2,1 3,2 F.L.A. - Total A 10,5 15,8 22,9 F.L.I. FULL LOAD POWER INPUT AT MAX ADMISSIBLE CONDITION F.L.I. - Circulator kw 0,3 0,4 0,7 F.L.I. - Total kw 5,3 7,5 11,1 M.I.C. MAXIMUM INRUSH CURRENT M.I.C. - Value A 66,5 104,4 104,8 Power supply 400/3/50 (+ NEUTRAL) +/- 6% Maximum Phase Unbalance: 2% The circulator is included in the total values calculation For non standard voltage please contact Clivet technical office The units are compliant with the provisions of European standards CEI EN and CEI EN

6 CORRECTION FACTOR FOR ANTIFREEZE SOLUTIONS % ethylene glycol by weight 5% 10% 15% 20% 25% 30% 35% 40% Freezing temperature C -2,0-3,9-6,5-8,9-11,8-15,6-19,0-23,4 Safety temperature C 3,0 1,0-1,0-4,0-6,0-10,0-14,0-19,0 Cooling Capacity Factor Nr 0,995 0,990 0,985 0,981 0,977 0,974 0,971 0,968 Compressor input Factor Nr 0,997 0,993 0,990 0,988 0,986 0,984 0,982 0,981 Internal exchanger Glycol solution flow Factor Nr 1,003 1,010 1,020 1,033 1,050 1,072 1,095 1,124 Pressure drop Factor Nr 1,029 1,060 1,090 1,118 1,149 1,182 1,211 1,243 The correction factors shown refer to water and glycol ethylene mixes used to prevent the formation of frost on the exchangers in the water circuit during inactivity in winter. FOULING CORRECTION FACTOR INTERNAL EXCHANGER m² C/W F1 FK x 10^(-4) 1,00 1, x 10^(-4) 0,97 0, x 10^(-4) 0,94 0,98 F1 = Heat power correction factor FK1 = Compressor power input correction factor PUMP PERFORMANCE Dp DP (kpa) ,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 Q (l/s) CURVE OF DISCHARGE HEAD WITH HYDRONIC ASSEMBLY DP[KPA]=USEFUL DISCHARGE HEAD Q[L/S]= WATER-FLOW RATE THE HEADS ARE INTENDED AS AVAILABLE AT THE UNIT CONNECTIONS EXCHANGER PRESSURE DROPS Dp DP (kpa) ,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 Q (l/s) Q (l/s) DP = PRESSURE DROP Q = WATER FLOW SIZE Minimal flow [l/s] 0,48 0,64 0,83 Maximum flow [l/s] 0,73 0,92 1,21 6

7 HEATING PERFORMANCE Size Ta ( C) DB/WB INTERNAL EXCHANGER WATER OUTLET TEMPERATURE ( C) kwt kwe kwt kwe kwt kwe kwt kwe kwt kwe kwt kwe / -15,4-10 / -10,5-7 / -8-5 / -5,4 2 / 1,1 7 / 6 10 / 8,2-15 / -15,4-10 / -10,5-7 / -8-5 / -5,4 2 / 1,1 7 / 6 10 / 8,2-15 / -15,4-10 / -10,5-7 / -8-5 / -5,4 2 / 1,1 7 / 6 10 / 8,2 7,15 2,83 7,46 3,12 7,76 3,40 8,06 3,68 8,36 3, ,94 2,89 9,15 3,20 9,36 3,52 9,57 3,83 9,78 4,14 9,98 4,45 10,0 2,94 10,2 3,27 10,3 3,59 10,5 3,92 10,7 4,24 10,8 4,57 10,7 2,97 10,8 3,31 11,0 3,64 11,1 3,98 11,3 4, ,1 3,12 13,2 3,48 13,3 3,84 13,4 4,20 13,5 4, ,7 3,24 14,8 3,62 14,9 3,99 15,0 4,37 15,2 4, ,7 3,32 15,8 3,70 15,9 4,09 16,1 4, ,36 3,45 9,63 3,94 10,9 4,44 12,2 4,94 13,4 5, ,2 3,60 11,9 4,07 12,6 4,55 13,3 5,02 13,9 5,49 14,6 5,97 12,8 3,70 13,2 4,17 13,7 4,64 14,1 5,11 14,5 5,58 14,9 6,05 13,9 3,77 14,1 4,24 14,4 4,71 14,7 5,19 14,9 5,66 15,2 6,13 17,3 4,03 17,2 4,54 17,2 5,05 17,1 5,57 17,1 6,08 17,1 6,59 19,4 4,23 19,4 4,80 19,3 5,37 19,3 5,94 19,2 6, ,7 4,36 20,7 4,97 20,7 5,59 20,7 6, ,43 4,58 10,6 5,24 11,7 5,91 12,8 6,57 13,9 7, ,2 4,77 14,9 5,47 15,5 6,17 16,2 6,87 16,9 7,57 17,6 8,26 16,7 4,89 17,2 5,62 17,7 6,34 18,2 7,07 18,7 7,79 19,1 8,52 18,3 4,97 18,7 5,71 19,1 6,46 19,5 7,20 19,9 7,95 20,2 8,69 23,0 5,25 23,3 6,08 23,5 6,91 23,8 7,74 24,0 8, ,6 5,47 25,9 6,37 26,3 7,27 26,7 8,17 27,1 9, ,8 5,59 27,3 6,55 27,8 7,50 28,3 8, Ta = External exchanger air intake temperature kwt = Heating capacity (kw) kwe = Compressor power input in kw Performances in function of the inlet/outlet water temperature differential = 5 C Data listed in the tables are based on plate exchangers without fouling and clean coils. For different situation it is necessary to use adeguate correction factors. INTEGRATED HEATING CAPACITIES Air temperature external exchanger inlet C (D.B. / W.B.) -5 / / -0.6 OTHERS 5 /3.9 Heating capacity multiplication coefficient 0, To obtain the integrated heating capacities (the real heating capacity considering the defrost cycles too), multiply the kwt value in the heating performance tables by the following coefficient. SOUND LEVELS Size Sound Power Level (db) Octave band (Hz) Sound pressure level Sound power level db(a) db(a) Measures according to ISO 3744 regulations, with respect to the EUROVENT 8/1 certification. The sound pressure is measured at 1 m from the external surface of the unit in open field conditions. Data referred to the following conditions : - unit at full load - outlet water internal exchanger 45 C External air temperature : 7 C D.B./6.0 C W.B. 7

8 ACCESSORIES Each accessory is marked by a configuration code, e.g. CMMBX. If the last letter is X, it means that the accessory is provided sepaseparately. If the code does not contain the letter X, the accessory is installed at the factory. HEOH - HIGH EFFICIENCY ONLY IN HEATING Option for energy optimization of the units, including the circulating pump use in direct current. This option is available only with the full optional version. WBAN (R-407C) COP 230/1/50 EN :2004 COP 400/3/50 EN : , ,14 4,14 4,10 The table summarizes the values of COP calculated in accordance with the law UNI EN14511:2008 * Due to its high efficiency, "Vulcan'" may be eligible for heat pump subsidies in Your Country. Please contact Your tax office or utility. AVAILABLE HEAD TO THE SYSTEM [kpa] DP (kpa) ,4 0,5 0,6 0,7 0,8 0,9 1,0 1,1 1,2 1,3 Q (l/s) Q [L/S] = WATER FLOW RATE DP [KPA] = USEFUL STATIC PRESSURE SYSTEM CIRCULATOR ABSORPTION CURVE Pcirc [kw] 0, ,27 0,26 0,25 0,24 0,23 0,22 0,21 0,20 0, ,18 0,17 0,16 0,15 0, ,13 0,12 0,11 0,10 0,09 0,08 0,07 0,06 0,05 0,04 0,1 0,2 0,3 0,4 0,5 0,6 0,7 0,8 0,9 Q [l/s] PCIRC [KPA] = ELECTRIC POWER ABSORBED Q [L/S] = WATER FLOW RATE 8

9 CCCA - Copper / aluminium condenser coils with acrylic lining The copper/aluminium evaporator coils with acrylic lining can be used in the room where the ambient air contains a concentration of salt and other not very aggressive agents. Configuration Detail CCCA1 - Copper / aluminium condenser coils with Fin Guard (Silver) treatment The Fin Guard Silver, for finned exchanger, is a polyurethane vernish waterproof (for waterworks, see and discharge water). It is also resistant to oil products and other different solvents. It hasn't any effects on the air side pressure drops. Configuration Detail CCCC - Copper / copper condenser coils The copper/copper condensing coil allows a better resistence to the natural agent like salt and sulphureous vapours. Configuration Detail EH246 - Modular integration electric heater 2-4 and 6kW HEATING ELEMENT WATER-SIDE PRESSURE DROP On request the unit can be provided with integration heating elements. Different powers can be selected based on needs. The electrical heating elements are immersed in a small 1-litre tank equipped with a safety thermostat The heating elements are activated by means of an on/off button as a main or additional component based on a temperature threshold, based on parameters defined at first start up. DP (kpa) Q (l/s) Q = WATER FLOW DP = PRESSURE DROP THE PRESSURE DROPS SHOWN IN THE GRAPH ARE TO BE SUBTRACTED, WITH PARITY OF FLOW RATE, FROM THE USEFUL STATIC PRESSURE. IF THE RESULT IS LESS THAN THE PRESSURE DROPS OF THE SYSTEM, IT IS ADVISABLE TO INSTALL AN EXTERNAL PUMP THAT ENSURES THE NECESSARY STATIC PRESSURE. Configuration Detail 9

10 3WV - Three-way valve Built-in 3-way valve for domestic hot water The unit is provided with a 3-way on/off valve to divert the flow of water to a hot water storage tank. Activation of the 3-way valve takes place by means of closure of a dry contact on the electrical board of the unit. As soon as this function is enabled, the set point of the unit is placed at the value established by the appropriate parameter in the electronic control. Pressure drop three-way valve (1) UNIT ELECTRIC PANEL (2) EXPANSION VESSEL (3) WATER SIDE SAFETY VALVE (4) PUMP (5) THREE-WAY VALVE (6) TERMINAL UNITS (7) UNDERFLOOR HEATING (8) WATERWORKS WATER INLET (9) SANITARY WATER Dp (kpa) ,5 0,7 0,9 1,1 1,3 1,5 1,7 1,9 2,1 2,3 2,5 2,7 2,9 3,1 Q (l/s) PRESSURE DROP THREE-WAY VALVE Q = WATER FLOW DP = PRESSURE DROP THE PRESSURE DROPS SHOWN IN THE GRAPH ARE TO BE SUBTRACTED, WITH PARITY OF FLOW RATE, FROM THE USEFUL STATIC PRESSURE. IF THE RESULT IS LESS THAN THE PRESSURE DROPS OF THE SYSTEM, IT IS ADVISABLE TO INSTALL AN EXTERNAL PUMP THAT ENSURES THE NECESSARY STATIC PRESSURE. Configuration Detail (-) Unit without hydronic assembly The unit can be requested without circulating pump, expansion vessel, safety valve water side and filling assembly. Configuration Detail PMX - Phase monitor The phase monitor allows to check the right presence of electric supply phases for 400/3/50 units. 10

11 SFSTR4N - Disposal for inrush current reduction HYDRONIC Disposal for inrush current reduction, for unit 400/3/50+N Starting up a motor directly can overload the electricity network, with start-up currents up to 8 times the nominal current. Thanks to the breakaway current reduction device, start-up takes place gradually, with the start-up current being limited during this period of time. The start-up current can therefore be reduced to times the nominal current, meaning that the power systems and protection devices can be sized with lower parameters. In sizes /1/50, the soft starter is included standard. Configuration Detail PBLC1X - Service handset for local control with 1.5-metre cable The service keyboard is necessary for the unit programming and setting. These operations must be done by qualified personnel without compromising the operation of the whole unit. The service keyboard is supplied with a connection cable of 1,5 m lenght. CMMBX - Serial communication module to supervisor (MODBUS) The serial communication module to supervisor (MODBUS) is connected with the principal module through a comb connection (see lay-out on electrical panel). In this way the remote assistance and supervision are available through standard MODBUS protocol. It is possible to connect to a single supervisor system up to 127 units. The connection to PC must be obtained through a converter RS485/232; the serial port RS232 admits as maximum a 10 m length. The serial communication module to supervisor (MODBUS) is necessary when the unit is connected to ELFOCONTROL. AMRX - Rubber antivibration mounts The rubber antivibration mounts reduce the vibrations of compressor during its operation and they are installed at the base toe. 11

12 SYSTEM ACCESSORIES KTFL1X - Hose kit for connection to chiller/heat pump. With connections of 1" The kit is composed of: Two hoses, length 300 and diameter 1, required for connection of the machine to the system. This kit can be used for heat pumps from 4 to 18kW KTFL2X - Hose kit for connection to chiller/heat pump. With connections of 1 1/4" The kit is composed of: Two hoses, length 300 and diameter 1 ¼, required for connection of the machine to the system. This kit can be used for heat pumps from 19 to 30kW KBQRE5X litres domestic hot water kit The kit is composed of: - Storage tank in Fe360b and internal vitrification treatment in accordance with DIN , external insulation in stiff polyurethane and exchange coil xx m2, maximum operating pressure 6 bar - Electrical heating element 4 kw for possible integration and anti-legionellosis cycle for boiler of 500 litres. - Electronic module for the management of the production of domestic hot water: DHW temperature setting, setting of time period for production of domestic hot water with priority based on a minimum temperature, management of anti-legionellosis cycle, control for three-way valve, management of the electrical heating element. The electronic module dialogues with the heat pump through the serial communication cable. - Three-way deviator valve 1 1/4 and non-return valve 1 1/4 to be installed in the system - Serial connection cable twisted and shielded for networks RS485 AGW22/24 with a length of 15 metres. - Serial communication card CMMBX to be connected in the heat pump Dimensions of boiler of 500 litres: 760 x 1690mm If this accessory is requested, the unit cannot be provided with the three-way valve installed on board. This is because it is to be installed on the system, near the hot water heater. KITERAX - Room thermostat Wall-mounted weekly electronic timer thermostat with summer, winter night adjustment. Range of adjustment +2 C/+35 C. Dimensions 123X88X23 mm. 12

13 KVMSP1X - Radiant panels management kit with 1" connections KVMSP2X - Kit for management of radiant panels with connections of 1 1/4" (KVMSP1X)The kit is made up of: 1 Mixer valve with three-point modulating actuator. Power box and modulating valve connection Temperature probe to be installed on the outlet of the radiator panels (l=20metres) Thermostat of maximum temperature 55 C Control for circulation pump to the radiator panel This kit may be used with 4-18kW heat pumps (KVMSP2X)The kit is made up of: 1 1/4 Mixer valve with three-point modulating actuator. Power box and modulating valve connection Temperature probe to be installed on the outlet of the radiator panels (l=20metres) Thermostat of maximum temperature 55 C Control for circulation pump to the radiator panel This kit may be used with 19-30kW heat pumps KVICX - Boiler control kit The kit is composed of: -Pair of two way motorized valves for boiler cut-off -Pair of two way motorized valves for heat pump cut-off Valve control electrical junction box KSAX litres hydraulic breaker Storage tank Fe360b and anti-corrosion treatment with organic enamelling, external insulation with polyurethane and polyethylene mat, thickness 50 mm maximum of operation 6 bar. Diameter 500 Height 900 N 8 connections CACSX - Domestic hot water kit control The module makes it possible to control the temperature of a domestic hot water tank, not provided by Clivet. The adjustment module comes with 2 temperature probes, 1 safety thermostat, power circuit and heating element control with protections against short circuits (the heating element is not provided by Clivet) and the installation box. As opposed to the control of domestic hot water performed directly by the machine electronics, the kit makes it possible to set re-fill time periods and anti-legionella cycles, and to manage a re-circulation pump on the storage tank. The storage tank must be suitably sized based on the combination with the selected heat pump. 13

14 PLUMBING DIAGRAM Heat pump + radiators + domestic hot water FAN COIL / RADIATORS HEAT PUMP SANITARY WATER PLUMBING DIAGRAM Heat pump + radiators + radiant panels + domestic hot water FAN COIL / RADIATORS HEAT PUMP RADIANT PANELS SANITARY WATER PLUMBING DIAGRAM Heat pump + radiators + radiant panels + domestic hot water + boiler BOILER FAN COIL / RADIATORS HEAT PUMP RADIANT PANELS SANITARY WATER 14

15 DIMENSIONAL DRAWING HYDRONIC M N W W4 (15) "G" O 476 P W1 4 W2 3 (15) 150 (1) COMPRESSOR (2) ELECTRICAL PANEL (3) INTERNAL EXCHANGER (4) EXTERNAL EXCHANGER (5) FAN (6) PUMP (7) EXPANSION VESSEL (8) WATER OUTLET 1" GAS (9) WATER INLET 1" GAS (10) ECONOMISER EXCHANGER (11) CONDENSATE DISCHARGE (12) AUXILIARY ELECTRIC HEATERS (OPTIONAL) (13) 3-WAY VALVE WATER LINE (OPTIONAL) (14) SANITARY WATER OUTLET 1"F GAS (OPTIONAL) (15) CLEARANCE ACCESS RECOMMENDED (G) BARYCENTRE Size M mm N mm O mm P mm Length mm Depth mm Height mm W1 kg W2 kg W3 kg W4 kg Operating weight kg Shipping weight kg

16 DIMENSIONAL DRAWING M N W W4 (15) 500 O 1 "G" P 508 W1 W2 3 (15) (1) COMPRESSOR (2) ELECTRICAL PANEL (3) INTERNAL EXCHANGER (4) EXTERNAL EXCHANGER (5) FAN (6) PUMP (7) EXPANSION VESSEL (8) WATER OUTLET 1" GAS (9) WATER INLET 1" GAS (10) ECONOMISER EXCHANGER (11) CONDENSATE DISCHARGE (12) AUXILIARY ELECTRIC HEATERS (OPTIONAL) (13) 3-WAY VALVE WATER LINE (OPTIONAL) (14) SANITARY WATER OUTLET 1"F GAS (OPTIONAL) (15) CLEARANCE ACCESS RECOMMENDED (G) BARYCENTRE Size 81 M mm 526 N mm 1017 O mm 266 P mm 242 Length mm 1526 Depth mm 557 Height mm 1224 W1 kg 92 W2 kg 48 W3 kg 83 W4 kg 43 Operating weight kg 266 Shipping weight kg 270 CLIVET SPA Feltre (BL) - Italy Tel Fax info@clivet.it CLIVET UK LTD Fareham, Hampshire - UK United Kingdom Tel (0) Fax + 44 (0) info@clivet-uk.co.uk CLIVET SAS France Tel (0) Fax + 33 (0) info.fr@clivet.com CLIVET ESPAÑA S.A. Madrid - España Tel Fax info@clivet.es CLIVET GmbH Norderstedt - Germany Tel (0) Fax + 49 (0) info.de@clivet.com CLIVET NEDERLAND B.V. Amersfoort - Netherlands Tel (0) Fax + 31 (0) info@clivet.nl CLIVET RUSSIA Moscow, Russia Tel Fax info.ru@clivet.com CLIVET MIDEAST FZC Dubai Silicon Oasis - Dubai,UAE Tel Fax info@clivetme.com CLIVET AIRCONDITIONING SYSTEMS (P) LTD Mumbai (INDIA) Tel Fax sales.india@clivet.com

AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION. Size

AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION. Size BT0B00GB-04 ELFO ENERGY COMPACT AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION Ultra-compact. Top noiselessness. Variable flow-rate circulator. Reduced energy consumption. WSAN-EE (R-4A) Size Cooling

More information

WSAT-EE AIR COOLED WATER CHILLER FOR OUTDOOR INSTALLATION

WSAT-EE AIR COOLED WATER CHILLER FOR OUTDOOR INSTALLATION BT0B00GB-02 - WSAT-EE - AIR COOLED WATER CHILLER FOR OUTDOOR INSTALLATION Ultra-compact. Top noiselessness. Variable flow-rate circulator. Reduced energy consumption. WSAT-EE - (R-4A) Size Cooling [kw]

More information

ELFOEnergy Ground. Technical Bulletin. Water cooled heat pump for indoors installation WSHN-EE RANGE

ELFOEnergy Ground. Technical Bulletin. Water cooled heat pump for indoors installation WSHN-EE RANGE Technical Bulletin BT06C002GB-11 ELFOEnergy Ground Water cooled heat pump for indoors installation WSHN-EE 17-121 RANGE Nominal heating capacity (W10/W45) from 6,68 kw to 38,7 kw Nominal cooling capacity

More information

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP EVH R-407C WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP Size Cooling Heating [kw] [kw] 7 2.0 1.9 11 2.6 2.5 15 3.9 3.3 5.2 5.5 25 7.3 6.7 31 8.9 8.4 41 10.7 9.8 REPLACE: BT02E009GB-01 The Versatemp

More information

WSAN-XEE AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION

WSAN-XEE AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION A WSAN-XEE 2-02 AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION CLASS ENERGY EFFICIENCY IN CLASS A Reduced energy consumption Optimised operation at partial loads Complete hydronic assembly supplied as

More information

ELFOEnergy Extended Inverter

ELFOEnergy Extended Inverter Technical Bulletin BT14F009GB-03 ELFOEnergy Extended Inverter AIR-COOLED INVERTER CHILLER FOR OUTDOOR INSTALLATION WSAT-XIN 21-171 RANGE PREMIUM Version Nominal cooling capacity (A35/W7) from 4 to 30 kw

More information

ELFOEnergy Duct Inverter

ELFOEnergy Duct Inverter Technical Bulletin BT14E002GB-02(EC1) ELFOEnergy Duct Inverter Air-water ductable liquid chiller for indoor or outdoor installation SERIES WSA-XIN 21-141 Nominal cooling capacity (A35/W7) da 4 a 31 kw

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

ELFOEnergy Extended Inverter

ELFOEnergy Extended Inverter Technical Bulletin BT14F008GB-00 ELFOEnergy Extended Inverter Air cooled inverter heat pump for outdoor installation WSAN-XIN 21-171 RANGE PREMIUM Version Nominal heating capacity (A7/W45) from 5 to 32

More information

CFI VERTICAL WATER RECESSED DUCTABLE TERMINAL UNIT

CFI VERTICAL WATER RECESSED DUCTABLE TERMINAL UNIT - 71 CFI -71 VERTICAL WATER RECESSED DUCTABLE TERMINAL UNIT CFI - 71 (---) Size Cooling Heating [kw] [kw] 8,7,2 31 12,7 29,3 41,2 33,4 51,7 43,1 71 21,6 5, REPLACE: B27AC-5-95 G4 The CFI series fan-coils

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

VERTICAL WATER RECESSED TERMINAL UNIT

VERTICAL WATER RECESSED TERMINAL UNIT ELFOROOM IN 5-15 VERTICAL WATER RECESSED TERMINAL UNIT ELFOROOM IN (ACQUA) Size Cooling Heating [kw] [kw] 5 1.47 2.85 11 2.81 5.51 15 3.49 6.76 The ELFO terminal unit is fitted with a motor offering a

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

ELFOENERGY LARGE 2 TECHNICAL BULLETIN HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES

ELFOENERGY LARGE 2 TECHNICAL BULLETIN HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES TECHNICAL BULLETIN ELFOENERGY LARGE HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES Nominal cooling capacity from to kw ELFOEnergy LARGE is a highly energy efficient

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

LZA High efficiency air to water heat pumps with HP compressor

LZA High efficiency air to water heat pumps with HP compressor High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

ELFOEnergy SHEEN. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XSi RANGE HIGH SEASONAL EFFICIENCY

ELFOEnergy SHEEN. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XSi RANGE HIGH SEASONAL EFFICIENCY Technical Bulletin BT17I022GB-00 ELFOEnergy SHEEN Air source inverter heat pump for outdoor installation WSAN-XSi 10.1 22.2 RANGE Nominal heating capacity (A7/W45) from 23,3 to 61 kw Nominal cooling capacity

More information

ELFOFresh Large. Technical Bulletin. Make-up unit, full fresh air, reversible heat pump. Series CPAN-U 17-51

ELFOFresh Large. Technical Bulletin. Make-up unit, full fresh air, reversible heat pump. Series CPAN-U 17-51 Technical Bulletin BT05L001GB-12 ELFOFresh Large Make-up unit, full fresh air, reversible heat pump Series CPAN-U 17-51 Ideal air exchange rates in shops and offices Cooling,heating and humidification

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

Air-to-water scroll chillers

Air-to-water scroll chillers Air-to-water scroll chillers Model CGA 040 to 115 Cooling capacity: 14-40 kw CG-PRC031B-GB Table of Contents Technical specifications...4 Standard configuration... 4 Hydraulic version... 4 Casing... 4

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL

More information

ELFOEnergy Edge. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XMi RANGE HIGH SEASONAL EFFICIENCY

ELFOEnergy Edge. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XMi RANGE HIGH SEASONAL EFFICIENCY Technical Bulletin BT16N009GB-00 ELFOEnergy Edge Air source inverter heat pump for outdoor installation WSAN-XMi 21 81 RANGE Nominal heating capacity (A7/W45) from 5 to 16 kw Nominal cooling capacity (A35/W7)

More information

VERSATEMP EQV-X TECHNICAL BULLETIN DIRECT EXPANSION HIGH EFFICIENCY PACKAGED AIR CONDITIONER EQV-X 3-21 SERIES WATER-AIR HEAT PUMP

VERSATEMP EQV-X TECHNICAL BULLETIN DIRECT EXPANSION HIGH EFFICIENCY PACKAGED AIR CONDITIONER EQV-X 3-21 SERIES WATER-AIR HEAT PUMP TECHNICAL BULLETIN VERSATEMP EQV-X DIRECT EXPANSION HIGH EFFICIENCY PACKAGED AIR CONDITIONER EQV-X 3-21 SERIES WATER-AIR HEAT PUMP Nominal cooling capacity from 1,4 to 4,1 kw Nominal heating capacity from

More information

CRIMSON & CRIMSON MAX

CRIMSON & CRIMSON MAX High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 +43 +65 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water

More information

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and

More information

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10 Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index

More information

ELFOEnergy Magnum - Heat pump

ELFOEnergy Magnum - Heat pump Technical Bulletin BT14E008GB-03 ELFOEnergy Magnum - Heat pump Air-cooled heat pump for outdoor installation WSAN-XIN 18.2-30.2 RANGE Nominal heating capacity (A7/W45) from 56 kw to 93 kw Nominal cooling

More information

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range is an efficient and low-noise product designed for medium to big applications. The water chillers are suitable for water outlet temperatures

More information

AQX Air handling units. Air flow 1, ,000 m 3 /h (350-44,400 l/s)

AQX Air handling units. Air flow 1, ,000 m 3 /h (350-44,400 l/s) AQX Air handling units Air flow 1,300-160,000 m 3 /h (350-44,400 l/s) Applications Commercial and Industrial New projects and renovation Suitable for new projects and renovations, Clivet AQX air handling

More information

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly

More information

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 +63 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,

More information

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Air/water cooled chillers and heat pumps 41 303 kw General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Configurations HP: Reversible heat pump LE: For connection to remote evaporator

More information

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors High Efficiency ir to Water Split System Heat Pumps With E.V.I. ompressors -20 +43 +65 HP E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata

More information

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures

More information

Water chillers water/water type SIGMA Technical information manual

Water chillers water/water type SIGMA Technical information manual Water chillers water/water type SIGMA Technical information manual 2 INDEX Technical features 1 Versions 3 Accessory versions 4 Technical data 7 Electrical data 11 Cooling capacity 12 Heating capacity

More information

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base

More information

ELFOSPACE BOX "CASSETTE" TYPE TERMINAL UNIT

ELFOSPACE BOX CASSETTE TYPE TERMINAL UNIT ELFOSPCE OX "CSSETTE" TYPE TERMINL UNIT ELFOSPCEOX (CQU) Size Cooling Heating [kw] [kw]. 4.0 9.09. 11.4.4..1 1...9 1. 1 8.11 1.8 41 9. 1.4 REPLCE: T00G-00 The Elfo Space ox water-cooled terminal unit is

More information

black Thermal power (A7:W45) kw Cooling power (A35;W7) kw

black Thermal power (A7:W45) kw Cooling power (A35;W7) kw black Thermal power (A7:W45) 35 60 kw Cooling power (A35;W7) 32 56 kw High efficiency and high temperature air/water heat pump with axial fans and scroll compressors 134a H 2 O 80 CONTROL MINIBOSS black

More information

Advance Split

Advance Split Engineering Data Manual Aqu@Scop Advance Split Air-to-Water DC Inverter Split Heat Pumps Models 005, 008, 012 & 014 2 to 16 kw Strength Points Most efficient heating technology with variable speed compressor.

More information

HT V2 HT Split

HT V2 HT Split Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single

More information

WZH Ground source heat pumps

WZH Ground source heat pumps Ground source heat pumps infolinia: +48 691 262 691 +60 C C.O.P. 5,1 HP heat pumps are particularly suitable for applications that utilise well water or ground source probes. These units have been designed

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL RMA ECO-FRIENDLY REFRIGERANT GAS AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the

More information

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems Technical Bulletin BT13F002GB-04 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems Technical Bulletin BT13F002GB-00 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR

More information

RTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N

RTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N A RE F S E -FRIEND Y R E IG RA N T G AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L RTA C TECHNICAL MANUAL 1 2 SUMMARY THIS MANUAL IS DIVIDED INTO SECTIONS. THEIR NAMES APPEAR IN THE HEADING

More information

Blue Box Epsilon Echos +

Blue Box Epsilon Echos + Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating

More information

30RH B Nominal cooling capacity kw Nominal heating capacity kw

30RH B Nominal cooling capacity kw Nominal heating capacity kw Air-to-Water Heat Pumps with Integrated Hydronic Module AQUASNAP Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products.

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 01/16 Supersedes: 12/13 Identification code Index Index... pag. 2 Identification code...»

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 04/11 Supersedes: 12/10 Identification code Index Index... pag. 2 Identification code...»

More information

AWR MTD2 XE. Versions

AWR MTD2 XE. Versions Versions ETING COOLING OT WTER ETING COOLING OT WTER ir/water reversible heat pump for water heating up to 58 C and operating limits down to -15 C external air temperature and domestic hot water production.

More information

HYDRONIC RESIDENTIAL

HYDRONIC RESIDENTIAL HYDRONIC RESIDENTIAL Chillers, reversible heat pumps and modular units for small and medium applications. Climaveneta. brand of Mitsubishi Electric Hydronics & IT Cooling Systems, presents the mini chiller

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

High temperature air-to-water heat pumps

High temperature air-to-water heat pumps Designed to replace conventional boilers and produce domestic hot water 4 High temperature hot water (+65 C) 4 Winter operation (-20 C) 4 High energy efficiency (CP) 4 Compact and quiet 4 Scroll compressors

More information

ELFOEnergy Ground Medium 2 - Multifunction

ELFOEnergy Ground Medium 2 - Multifunction Technical Bulletin BT15A008GB-06 ELFOEnergy Ground Medium 2 - Multifunction Water cooled heat pump with simultaneous hot / cold water production for indoor installation WSHN-XEE2 MF 10.2-120.2 RANGE Nominal

More information

Air Cooled Chillers & Heat Pumps WinPACK HE-A

Air Cooled Chillers & Heat Pumps WinPACK HE-A Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 1 Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 Cooling capacity: 91,6-345 kw Heating capacity: 110,5-357 kw Class

More information

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry System System Simple and flexible direct expansion solutions for the commercial sector and industry System is the autonomous solution for climate control in small and medium shops. The cooling or thermal

More information

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140

More information

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES Ground source heat pumps +60 C C.O.P. 5,1 heat pumps are particularly suitable for applications that utilise ground source probes.these units have been designed for use with radiant floor heating systems

More information

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential

More information

PRODUCT GUIDE

PRODUCT GUIDE PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive,

More information

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable

More information

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation

More information

TCHE-THHE TCEE

TCHE-THHE TCEE K11206-GB ed. 6 TCHE-THHE 155 2130 TCEE 155 2130 Q-Flow range Macrosystem 50,2 124,5 kw TCHE-THHE - Water cooled water chillers and heat pumps units with environmentally friendly refrigerant. Range with

More information

AQUASNAP JUNIOR 30RHV

AQUASNAP JUNIOR 30RHV High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11

More information

O L R E RGA ST RA N AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL

O L R E RGA ST RA N AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL -FRIEND A R E IG RA N T G RGA ST RE F S Y E O L C AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL 1 2 SUMMARY THIS MANUAL IS DIVIDED INTO SECTIONS. THEIR NAMES APPEAR IN THE

More information

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water Designed to replace a conventional boiler and produce domestic hot water Heating capacity : 16 to 25 Heating Hydraulic module ENVIRONMENTALLY HFC R4A PROTECTION DE FRIENDLY L'ENVIRONNEMENT USE CIAT is

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw. 1 Компрессорно-конденсаторные агрегаты Chiller AQH DCI 20 to 30 Air Cooled Water Inverter Heat ump Engineering Data Manual 20 to 30 kw 20 to 30 kw Specifications 3 AQH DCI Finned coil optimized in ing

More information

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor

More information

Neosys Product catalogue

Neosys Product catalogue 00/0 Neosys Product catalogue Providing indoor climate comfort NEOSYS 00 0 kw Air cooled chiller/heat pump YEAR WARRANTY* Quality makes the difference* Introduction to the range NEOSYS is providing chilled

More information