1 - 71 CFI -71 VERTICAL WATER RECESSED DUCTABLE TERMINAL UNIT CFI - 71 (---) Size Cooling Heating [kw] [kw] 8,7, ,7 29,3 41,2 33,4 51,7 43, ,6 5, REPLACE: B27AC-5-95 G4 The CFI series fan-coils are the air handling terminal units in air-conditioning systems that use water as the cooling and/or heating fluid. Sizes -71, designed for installation behind false walls, and feature very compact dimensions and extremely low noise levels, thanks to the internal and external insulation. Sizes 91 and 121 can be installed either on the ceiling or the floor. Large panels allow access to all the components. Generous internal insulation means that noise levels have been reduced significantly. In addition, the units feature a large number of accessories that simplify installation and respond to a variety of different system needs. BT7L8GB-1 CERTIFIED QUALITY SYSTEM UNI EN ISO 91:8

2 - 71 STANDARD UNIT SPECIFICATIONS STRUCTURE «ALUZINK» cabinet complete with anchoring brackets. Internal open cell polyurethane soundproofing, external closed cell polyurethane anti-condensate lining and heat insulation. INTERNAL EXCHANGER finned exchanger, made from copper pipes arranged in staggered rows and mechanically expanded for better adherence to the collar of the fins. The fins are made from aluminium with a special corrugated surface, set a suitable distance apart to ensure maximum heat exchange efficiency. FAN Centrifugal double screw 3-speed fan, statically and dynamically balanced (2/1/5 single-phase). ACCESSORIES - hot water heating coil (2R) - electric heaters. - Discharge plenum for circular ducts Electronic version with 3-speed board for the fan CLIVET TALK TERMINAL electronic for HID-T2 or HID-T3 thermostats (ELFOControl) - HID-E1 Three-speed selector + ON/OFF for wall mounting - HID-E2 Simplified room control S/W+3V+on/off for wall mounting - HID-E3 Multi-function room control for wall mounting - HID-T2 electronic ambient control - HID-TI2 flush-mounted electronic ambient control - HID-T3 electronic ambient control FILTRATION Flat filter, made up of a galvanized plate frame with galvanized and electricwelded protective mesh, and regenerable filtering media made from polyester fibre sized with synthetic resins. G4 efficiency according to CEN-EN 779 standard (Eurovent class EU4/5 - average efficiency 9.1% ASHRAE Atm). Self-extinguishing (resistance to fire class 1 - DIN 53438). TRAY Thermoformed ABS condensate collection tray fitted with drain pipe. ELECTRICAL PANEL terminal block for connection to room thermostat; CONNECTIONS Water coil fittings 3/4 () - 1 (31-71) CONFIGURATION CODE (1) (2) (3) (5) CFI 23M RF M (Std) RF (Std) - (Std) - (Std) 31 4TN R3 CV3FS SP1 41 CTS SPZB (1) VOLTAGE Supply voltage 4/3/5+N (4TN) The voltage 4/3/5+N is furnished only to people who install the electric heaters. Supply voltage 23/1/5 (23M) standard This voltage does not allow the possibility to install the electric heaters. (2) INTAKE Floor air inlet (R3) Front air inlet (RF) standard (4) REMOTE COMMUNICATION SERIAL PORT Remote communication serial port: not required (-) standard RS485 remote communication serial port (SP1) serial port with MODBUS (RS 485) output for remote communication Wireless serial for wireless remote control (SPZB) Wireless connection to supervisor (3) ELECTRONIC VERSION Electric version: not required (-) standard terminal block for connection to room thermostat; Electronic version with 3-speed board for the fan (CV3FS) CLIVET TALK TERMINAL electronic for HID-T2 or HID-T3 thermostats (ELFOControl) (CTS) 2

3 - 71 GENERAL TECHNICAL SPECIFICATIONS Size COOLING Cooling capacity 1 kw 8,7 12,7,2,7,7 Sensible capacity 1 kw 6,69 9,71 11,2 14,3,3 Total power input 1 kw,47,61,61,75 1,43 HEATING Heat output 2 kw,2 29,3 33,4 43,1 5 INTERNAL EXCHANGER Front surface m2,,29,37,43,53 Number of rows Nr Water content l 3,2 4 4,8 5,6 6,4 Water flow-rate l/s,42,61,73,9 1,3 AIR HANDLING SECTION FANS (OUTLET) Type of fans 3 CFG CFG CFG CFG CFG Air flow 4 l/s Max outside static pressure 5 Pa CONNECTIONS Water fittings 3/4' 1' 1' 1' 1' Condensate discharge POWER SUPPLY Standard power supply V 23/1/5 23/1/5 23/1/5 23/1/5 23/1/5 DIMENSIONS Length mm Depth mm Height mm STANDARD UNIT WEIGHTS Shipping weight kg (1) nominal air flow ambient air 26 C DB / 19.5 C WB water inlet 7 C and outlet 12 C (2) nominal air flow ambient temperature C water inlet 7 C and outlet 6 C (3) CFG = centrifugal fan (4) Max outside static pressure (5) rated flow, maximum speed, including the air filter Voltage: 23/1/5 ELECTRICAL DATA Size F.L.A. - FULL LOAD CURRENT AT MAX ADMISSIBLE CONDITIONS F.L.A. - Total A F.L.I. FULL LOAD POWER INPUT AT MAX ADMISSIBLE CONDITION F.L.I. - Total kw M.I.C. MAXIMUM INRUSH CURRENT M.I.C. - Value A OPERATING RANGE Size Max. water inlet temperature C Min. air temperature inlet (D.B.) C Max. air temperature inlet (D.B.) C Min. water inlet temperature C Maximum water side pressure bar DB = dry bulb WB = wet bulb 3

4 - 71 SOUND LEVELS FAN SPEED: Low speed (L) Size Sound Power Level (db) Octave band (Hz) Sound pressure level Sound power level The sound levels refer to the unit with standard installation, ducted outlet and intake for 1,5 m, air not going to the test ambient and fans at min, medium and max speed. Sound pressure level measured at distance 1 m from the external unit surface db(a) db(a) FAN SPEED: Medium speed (M) Size Sound Power Level (db) Octave band (Hz) Sound pressure level Sound power level db(a) db(a) FAN SPEED: High speed (H) Size Sound Power Level (db) Octave band (Hz) Sound pressure level Sound power level db(a) db(a) INTERNAL EXCHANGER PRESSURE DROP DP (KPa) 24 Q = WATER FLOW DP = PRESSURE DROP Q (l/s) 4

5 - 71 PERFORMANCE CORRECTION COEFFICIENTS (AIR STANDARD FLOW-RATE ASSUMED AS 1) CFI V H M L H M L H M L H M L H M L KF KS KT NOMINAL AIR FLOW REFERRED TO MAX DECLARED EXTERNAL STATIC PRESSURE HIGH SPEED (H) MEDIUM SPEED (M) LOW SPEED (L) KF = COOLING PERFORMANCE MULTIPLICATION COEFFICIENT KS= SENSIBLE OUTPUT MULTIPLICATION COEFFICIENT KT = HEATING PERFORMANCE MULTIPLICATION COEFFICIENT CF CFI CFI 31 DP (Pa) L M H Q (m³/h) DP (Pa) L M H Q (m³/h) CF 41 CF 51 CFI 41 CFI 51 DP (Pa) L M H Q (m³/h) DP (Pa) L M H Q (m³/h) HIGH SPEED (H) MEDIUM SPEED (M) LOW SPEED (L) Q = AIR FLOW DP = PRESSURE DROP DP(Pa) CFI CF L M H Q (m³/h) 5

6 - 71 COOLING PERFORMANCE Size Ta ( C) DB/WB EXTERNAL EXCHANGER WATER INLET / OUTLET TEMPERATURE (ºC) 6 / 11 7 / 12 9 / 14 / 13 / kwf kws kwf kws kwf kws kwf kws kwf kws /,4 24 / /,6 27 / 19,5 28 /,3 3 / 21,9 /,4 24 / /,6 27 / 19,5 28 /,3 3 / 21,9 /,4 24 / /,6 27 / 19,5 28 /,3 3 / 21,9 /,4 24 / /,6 27 / 19,5 28 /,3 3 / 21,9 /,4 24 / /,6 27 / 19,5 28 /,3 3 / 21,9 5,5 5,21 4,98 4,8 3,98 3,97 3,51 3,51 2,19 2,19 6,93 6,2 6, 5,62 4,92 4,81 4,37 4,37 3,7 3,7 8,59 6,75 7,72 6,35 6, 5,56 5,53 5,16 4,3 3,97 9,64 7,9 8,7 6,69 7,4 5,91 6,32 5,52 4,6 4,34,6 7,44 9,65 7,5 7,89 6,27 7, 5,88 5,13 4,71 12,8 8,16 11,8 7,78 9,83 7,1 8,89 6,63 6,24 5,47 8,5 7,58 7,31 6,99 5,87 5,8 5,19 5,19 3,23 3,23,1 8,75 9,7 8,16 7,21 7, 6,41 6,41 4,5 4,5 12,5 9,79 11,3 9, 9,3 8,8 8,8 7,51 5,88 5,79 14,,3 12,7 9,71,3 8,58 9,21 8,1 6,72 6,31,5,8 14,1,2 11,5 9,9,3 8,53 7,49 6,85,6 11,8 17,1 11,3 14,3,2 12,9 9,6 9,13 7,94 9,63 8,84 8,7 8,16 6,95 6,8 6,13 6,12 3,9 3,9 12,2,2,8 9,49 8,56 8,14 7,58 7,47 5,28 5,28, 11,3 13,5,7,8 9,34 9,6 8,67 6,9 6,67 16,8 11,9,2 11,2 12,3 9,9 11, 9,24 7,91 7,,5 12,5 16,8 11,8 13,7,5 12,4 9,82 8,87 7,84,1 13,6,4 13, 17,1 11,7,5 11, 11, 9,7 11,9 11,2,7,3 8,6 8,55 7,59 7,59 4,79 4,79 14,9 12,9 13,4 12,,6,3 9,43 9,43 6,63 6,63,5 14,4 16,6 13,6 13,3 11,9 11,9 11, 8,66 8,52,7,1,7 14,3,2 12,6 13,6 11,8 9,9 9,29,9,8,8, 17, 13,4,3 12,5 11,,1 27,5 17,4,3 16,5 21,2 14,9 19,2 14,1 13,5 11,7,1 14,3 13,7 13,1 11,,9 9,75 9,75 6,9 6,9 19, 16,4 17,,3 13,5 13,2 12, 12, 8,46 8,46 23,5,4 21,1 17,3 16,9,2,2 14,1 11,,9 26,3 19,3 23,7,3 19,2 16,1 17,3,1 12,6 11,9 29,,2 26,3 19,2 21,5 17,1 19,3 16,1 14, 12,9 34,8,2 32, 21,1 26,7 19,1 24,1,1 17,1, Ta = air intake temperature DB = dry bulb WB = wet bulb kwf = Cooling capacity in kw kws = sensible cooling capacity (kw) 6

7 - 71 HEATING PERFORMANCE Size Ta ( C) DB/WB EXTERNAL EXCHANGER WATER INLET / OUTLET TEMPERATURE (ºC) kwt kwt kwt kwt kwt,7,6,4,3 3,2 8,24 13,1 17,9,8 27, ,77 11,6 16,4 21,2 26, 5,79,6,5,2, 4,8 9,68 14,5 19,3 24, 3,32 8, 13, 17,8,5,5,6 29,6 36,7 43,7 12, 19, 26, 32,9 39,9 9,9 16,9 23,8 3,8 37,6 8,48,5,4 29,3 36,1 7,5 14,1 21, 27,9 34,7 4,89 12,,9,8 32,5,,9 33,8 41,7 49,5 14,1 21,9 29,7 37,5 45,2 11,6 19,5 27,3 35, 42,7, 17,9,7 33,4 41, 8,4 16,3 24,1 31,8 39,3 5,94 13,9 21,7 29,4 36,9,9 33,3 43,6 53,9 64,2 17,7 28, 38,2 48,4 58,6 14,6 24,9 35,1 45,2 55,3 12,5,8 33, 43,1 53,1,4,7 3,9 41, 5,9 7, 17,6 27,8 37,9 47,7 29,2 42,5 55,7 68,9 82,1,6 35,7 48,8 61,9 74,9,6 31,7 44,8 57,8 7,7,9 29,1 42,1 55, 67,9 13,2 26,4 39,4 52,3 65,1 9,,5 35,5 48,3 61, DB = dry bulb WB = wet bulb Ta = air intake temperature kwt = Heating capacity (kw) difference between inlet / outlet water temperature = C 7

8 - 71 accessories (A)standard unit (1)Air discharge plenum for circular ducts (2)Electric heating coil (3)water heating coil (4)return air plenum with fresh air intake A (MCRX)Air discharge plenum for circular ducts 2 This section makes easy the unit connections when is request the air distribution throw the circular ducts. It can be fixed directly to the discharge flange or after the heating coil section, when installed. It is made of galvanized steel casing with 3 flanges ø (4 flanges for unit size 41 and 51). They are sized to obtain an air speed of about 4-6 m/s in the circular ducts (with nominal air flow and using all the collars). CF A B C (EH )Electric heating coil Whenever hot water is not available, the electric heating elements can be used for the purposes previously described. It is supplied with the circuit breaker, electronic control card and safety thermostat against overheating. It has a galvanized sheet housing and finned aluminium heating elements, giving a fast and uniform heat diffusion. Please see the available capacities in the following table. Air side pressure drop, depending from capacity, is variable between minimum 5 Pa to maximum Pa. N.B. the electric heating elemets need tension of 4/3/5Hz +/- %. GRANDEZZE kw X X kw - - X X X 9 kw X X kw - - X X X 8

9 - 71 (CHW2X)water heating coil This section is necessary when heat pump is not a feasible solution. In fact in extreme winter conditions the ambient temperature may fall below the minimum operating range of the unit or the unit may not operate at an economically viable conditions. The hot water coil is designed to be fitted to the ductwork or directly to the discharge flange. This section may be fitted with right or left side connections. N.B. For headers with connections ont he right side the units front section increase. This section is mabe of a galvanized steel frame and the coil is made of copper tubes and aluminium fins. Performances of hot water coil (2 rows) CF Ta ( C) DB/WB Ti/To 4 / 3 5 / 4 55 / 45 6 / 5 kwt kwt kwt kwt 7 / 6 8 / 7 kwt kwt rated flow, maximum speed, including the air filter Ti/To = water temperature inlet/outlet ( C) Pa (Kpa) HOT WATER COIL PRESSURE DROP: WATER SIDE Q = WATER FLOW DP = PRESSURE DROP Q (l/s) DP (Pa) HOT WATER COIL PRESSURE DROP: AIR SIDE Q = WATER FLOW DP = PRESSURE DROP Q (l/s)

10 - 71 (CV3FS)Electronic version with 3-speed board for the fan The version with the three-relay card, indispensable for the use of the unit with the thermostats of the series HID-E2, HID-E3, HID-E4, makes it possible to isolate the voltage to the electric fan, thus preventing it from passing directly to the thermostat. This solution has been implemented to prevent voltage overloads at the thermostat, which would occur with connection directly to the electric fan. The card also prevents return current from the motors, allowing the control of several units connected in parallel to a single electro-mechanical thermostat of the series HID-E_ optional accessory (HID-E1)HID-E1 Three-speed selector + ON/OFF for wall mounting electromechanical room thermostat HID-E1 for wall installation. It allows:-the selection of 3 speeds (MIN-MED-MAX)-the manual change Summer/Winter (HID-E2)HID-E2 Simplified room control S/W+3V+on/off for wall mounting HID-E2 electromechanical room thermostat for wall installation It allows: -setting of the desidered temperature (-3 C) -selection of the 3 speeds (MIN - MED - MAX) -on/off -manual mode switching Summer / Winter -unbroken ventilation or controlled by a thermostat It can be connected to the remote air probe (HID-E3)HID-E3 Multi-function room control for wall mounting electro-mechanical ambient thermostat HID-E3 for wall mounting It enables: - automatic fan speed adjustment (MIN - MED - MAX) -silent operation (fan min. speed) -on/off -ambient temperature control through control knob: the knob central position corresponds to the comfort setting ( C in heating, 24 C in cooling), the temperature can be changed by +/- 5 C from the comfort condition by turning the knob -automatic selection of Summer/Winter season: the choice between heating and cooling is automatically made detecting the temperature of the outlet water at the fancoil (water temperature lower than 17 C=cooling operation, water temperature higher than 21 C=heating operation) -Hot start function: while heating the fan does not start unless the thermal coil is sufficiently hot -destratification cycle -dirty filter signal -water min. temperature probe (supplied separately)-on/off control for hot/cool water valve coil for 2 and 4 tube system controlled by a termostat (HID-E4)HID-E4 Multi-function room control for -V valves electro-mechanical room thermostat HID-E4 for wall mounting with proportional outlets for 2 or 4 pipe systems Allows: - 24 V power supply -setting of desired temperature (-3 C) -Summer/winter manual changeover -fan speed selection (MIN - MED - MAX) -control - V coil valves for hot/cold water for thermostat-controlled 2 or 4 pipe systems with adjustable working range and neutral zone (respectively 1-5 C and 1-4 C) Set up for connection of remote air probe Dimensions:4 x 82 x 27 mm (PTABX)Remote probe for ambient air temperature for electromechanical thermostats. Ambient air probe applicable to thermostat, cable lenght 1m The remote room air sensor can be connected to the HID-E_ room thermostats complete with sensor input (HID-E1 excepted).

11 - 71 (CTS)CLIVET TALK TERMINAL electronic for HID-T2 or HID-T3 thermostats(elfocontrol) This is a card for control of the unit which, in addition to basic functions, allows it to be connected to a network of similar units managed centrally by ELFOControl, which in turn can be connected to a supervisor, moreover it can also manage a linked mini-net,of maximum 8 units, by RS485 or Wireless serial ports, with a Master-Slave system. This type of electronic card is suited for communicating via RS485 or wireless if connected to SP1 or SPZB devices. The microprocessor control installed in the unit receives operating settings from one of the following devices: HID-T2 - room control for wall installation HID-T3 - room control for wall installation with humidity probe ELFOControl Its functions are: - control of minimum temperature of system water temperature - manual or automatic control of fan speed - control of ON-OFF water valve - digital input for remote on/off function or winter/summer - control of fan / actuator of external air shutter - on/off control of electrical heating element or cumulative alarm relay. The room temperature probe includes the ClivetTalkTerminalSpace electronics. The plug-in card is provided standard on this unit. It provides the modulating -v signal for the management of proportional water valves or electrical heating elements optional accessory (HID-T2)HID-T2 electronic ambient control The HID-T2 room thermostat makes it possible to interface with the regulation module of units equipped with Clivet- TalkTerminal Space electronics and to manage one or more thermostat units. The room thermostat allows the following functions: -Setting of desired temperature - Selection of the three speeds (MIN - MED - MAX) manually or automatically -On/off _ Change Summer/winter automatically or manually with digital input - Selection of economic operation -Setting of unit operation parameters -Setting of fan-only mode -Control of external air shutter and control of motorized air outlet grille, if present -Management of diagnostics with specific code for type of error (HID-TI3)HID-TI2 flush-mounted electronic ambient control The built-in room control HID-TI2 allows direct link with the regulation module ClivetTalkTerminal Space and allows managing of one or more units. The room thermostat handles the following functions: - temperature selection; - 3 speeds selection (MIN - MED - MAX) manual or automatic mode; - on/ff; - change over Summer/Winter that can be automatic or remote (by digital input); - Economy mode selection; - unit parameters set; - single ventilation mode; - driving of external air shutter and motorized inlet grill; - diagnostic management with code for any type of error. The thermostat is linked to the unit through a shielded wire at the maximum distance of mt. The supplied fixing hangs allow mounting the thermostat to the plastic boxes (not supplied) normally used in the houses. For any question about ELFOControl net, please consult the specific sections. (HID-T3)HID-T3 electronic ambient control The HID-T3 room climate control makes it possible to interface with the regulation module of units equipped with ClivetTalkTerminal Space electronics and to manage one or more thermostat units. The room thermostat allows the following functions:-setting of desired temperature - Selection of the three speeds (MIN - MED - MAX) manually or automatically-on/off _ Change Summer/winter automatically or manually with digital input- Selection of economic operation-setting of unit operation parameters-setting of fan-only mode-control of external air shutter and control of motorized air outlet grille, if present-management of humidity probe-humidity display-management of diagnostics with specific code for type of error Dimensions: 4X82X27 mmthe thermostat is connected to the unit by means of a shielded twisted pair at a distance of up to m. For connections to the ELFOControl network, refer to the specific sections. (SP1X)RS485 remote communication serial port The serial port with MODBUS protocol allows the cable connection between the units and the ELFOControl system, allowing the operation parameters control and modification optional accessory 11

12 - 71 DIMENSIONAL DRAWING (1) OUTLET CENTRIFUGAL FAN (3) POWER INPUT (4) DRAIN STUB (5) EXCHANGER WATER INLET (6) EXCHANGER WATER OUTLET (7) ELECTRICAL PANEL (8) ACCESS TO THE ELECTRICAL PANEL (8) FAN ACCESS PANEL (9) HOLE TO HANG UNIT Size Dimensional dwg. no A mm B mm C mm D mm E mm F mm G mm H mm I mm L mm M mm Length mm Depth mm Height mm

13 FUNCTIONAL CLEARANCES TERMINALS - 71 FRONTAL RETURN AIR INLET (FR) BOTTOM INTAKE (R3) FR R3 13

14 - 71 CLIVET SPA Feltre (BL) ITALY Tel Fax info@clivet.it CLIVET ESPAÑA S.A. Madrid - SPAIN Tel Fax info@clivet.es CLIVET UK LTD Fareham (Hampshire) U.K. Tel () Fax + 44 () info@clivet-uk.co.uk CLIVET NEDERLAND B.V. Amersfoort - Netherlands Tel () Fax + 31 () info@clivet.nl CLIVET SPA BUREAU DE LIAISON EN FRANCE Verrierès le Buisson - FRANCE Tel () Fax + 33 () info.fr@clivet.com CLIVET GmbH Norderstedt - GERMANY Tel. +49 () Fax +49 () info.de@clivet.com CLIVET TFAIR SYSTEMS (P)LTD. Malur - INDIA Tel /5 Fax info@clivettfa.com The data contained in this bulletin is not binding and may be changed by the manufacturer without prior notice. All reproduction, even partial, is prohibited. Copyright - CLIVET S.p.A. - Feltre (BL) - Italy

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP EVH R-407C WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP Size Cooling Heating [kw] [kw] 7 2.0 1.9 11 2.6 2.5 15 3.9 3.3 5.2 5.5 25 7.3 6.7 31 8.9 8.4 41 10.7 9.8 REPLACE: BT02E009GB-01 The Versatemp

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

VERTICAL WATER RECESSED TERMINAL UNIT

VERTICAL WATER RECESSED TERMINAL UNIT ELFOROOM IN 5-15 VERTICAL WATER RECESSED TERMINAL UNIT ELFOROOM IN (ACQUA) Size Cooling Heating [kw] [kw] 5 1.47 2.85 11 2.81 5.51 15 3.49 6.76 The ELFO terminal unit is fitted with a motor offering a

More information

ELFOSPACE BOX "CASSETTE" TYPE TERMINAL UNIT

ELFOSPACE BOX CASSETTE TYPE TERMINAL UNIT ELFOSPCE OX "CSSETTE" TYPE TERMINL UNIT ELFOSPCEOX (CQU) Size Cooling Heating [kw] [kw]. 4.0 9.09. 11.4.4..1 1...9 1. 1 8.11 1.8 41 9. 1.4 REPLCE: T00G-00 The Elfo Space ox water-cooled terminal unit is

More information

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems Technical Bulletin BT13F002GB-00 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR

More information

AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION. Size

AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION. Size BT0B00GB-04 ELFO ENERGY COMPACT AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION Ultra-compact. Top noiselessness. Variable flow-rate circulator. Reduced energy consumption. WSAN-EE (R-4A) Size Cooling

More information

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems Technical Bulletin BT13F002GB-04 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR

More information

ELFOFresh Large. Technical Bulletin. Make-up unit, full fresh air, reversible heat pump. Series CPAN-U 17-51

ELFOFresh Large. Technical Bulletin. Make-up unit, full fresh air, reversible heat pump. Series CPAN-U 17-51 Technical Bulletin BT05L001GB-12 ELFOFresh Large Make-up unit, full fresh air, reversible heat pump Series CPAN-U 17-51 Ideal air exchange rates in shops and offices Cooling,heating and humidification

More information

WSAT-EE AIR COOLED WATER CHILLER FOR OUTDOOR INSTALLATION

WSAT-EE AIR COOLED WATER CHILLER FOR OUTDOOR INSTALLATION BT0B00GB-02 - WSAT-EE - AIR COOLED WATER CHILLER FOR OUTDOOR INSTALLATION Ultra-compact. Top noiselessness. Variable flow-rate circulator. Reduced energy consumption. WSAT-EE - (R-4A) Size Cooling [kw]

More information

VERSATEMP EQV-X TECHNICAL BULLETIN DIRECT EXPANSION HIGH EFFICIENCY PACKAGED AIR CONDITIONER EQV-X 3-21 SERIES WATER-AIR HEAT PUMP

VERSATEMP EQV-X TECHNICAL BULLETIN DIRECT EXPANSION HIGH EFFICIENCY PACKAGED AIR CONDITIONER EQV-X 3-21 SERIES WATER-AIR HEAT PUMP TECHNICAL BULLETIN VERSATEMP EQV-X DIRECT EXPANSION HIGH EFFICIENCY PACKAGED AIR CONDITIONER EQV-X 3-21 SERIES WATER-AIR HEAT PUMP Nominal cooling capacity from 1,4 to 4,1 kw Nominal heating capacity from

More information

VULCAN AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION

VULCAN AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION VULCAN AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION Operation only in heating Operation up to -18 C Reduced energy consumption Water production from 60 C to -10 C external air *Due to its high efficiency,

More information

WSAN-XEE AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION

WSAN-XEE AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION A WSAN-XEE 2-02 AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION CLASS ENERGY EFFICIENCY IN CLASS A Reduced energy consumption Optimised operation at partial loads Complete hydronic assembly supplied as

More information

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system

More information

Blower-YEFB-020-3R-1maxVel

Blower-YEFB-020-3R-1maxVel YEFB DUCTED UNIT GENERAL FEATURES Structure It is made of 1,0 mm thick galvanised steel. Despite this thickness, a special tool for production allowed to keep a good stiffness, in order to reduce the risk

More information

ELFOEnergy Duct Inverter

ELFOEnergy Duct Inverter Technical Bulletin BT14E002GB-02(EC1) ELFOEnergy Duct Inverter Air-water ductable liquid chiller for indoor or outdoor installation SERIES WSA-XIN 21-141 Nominal cooling capacity (A35/W7) da 4 a 31 kw

More information

ELFORoom 2 TECHNICAL BULLETIN WATER TERMINAL FOR VERTICAL AND HORIZONTAL CASED OR UNCASED INSTALLATION

ELFORoom 2 TECHNICAL BULLETIN WATER TERMINAL FOR VERTICAL AND HORIZONTAL CASED OR UNCASED INSTALLATION TECHNICAL BULLETIN WATER TERMINAL FOR VERTICAL AND HORIZONTAL CASED OR UNCASED INSTALLATION HOMOGENOUS TEMPERATURES AT ALL TIMES Eliminates the stratifications of the air temperature thanks to the continuous

More information

Conditioning your ambient, maximising your comfort.

Conditioning your ambient, maximising your comfort. Centrifugal fancoils for surface mounting or recessed installation. Cooling capacity from 0,6 to 7,6 kw and heating capacity from 0,8 to 9 kw. Air flow from 100 to 1500 m3/h. Cassette with radial fan.

More information

AQX Air handling units. Air flow 1, ,000 m 3 /h (350-44,400 l/s)

AQX Air handling units. Air flow 1, ,000 m 3 /h (350-44,400 l/s) AQX Air handling units Air flow 1,300-160,000 m 3 /h (350-44,400 l/s) Applications Commercial and Industrial New projects and renovation Suitable for new projects and renovations, Clivet AQX air handling

More information

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy

More information

Fan Coil Range HYDRONIC TERMINALS

Fan Coil Range HYDRONIC TERMINALS Fan Coil Range HYDRONIC TERMINALS This document can be subjected to variations. Descriptions, performance data, images and diagrams are indicative only. For further information contact Climaveneta Comunications/Marketing

More information

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9

More information

Conditioning your ambient, maximising your comfort.

Conditioning your ambient, maximising your comfort. Centrifugal fan coils for surface mounting or recessed installation. Cooling capacities from 0,6 to 7,6 kw and heating capacity from 0,8 to 9 kw. Air flow from 100 to 1500 m 3 /h. Cassette with radial

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

ELFOEnergy Extended Inverter

ELFOEnergy Extended Inverter Technical Bulletin BT14F009GB-03 ELFOEnergy Extended Inverter AIR-COOLED INVERTER CHILLER FOR OUTDOOR INSTALLATION WSAT-XIN 21-171 RANGE PREMIUM Version Nominal cooling capacity (A35/W7) from 4 to 30 kw

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT 1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»

More information

ELFOEnergy Ground. Technical Bulletin. Water cooled heat pump for indoors installation WSHN-EE RANGE

ELFOEnergy Ground. Technical Bulletin. Water cooled heat pump for indoors installation WSHN-EE RANGE Technical Bulletin BT06C002GB-11 ELFOEnergy Ground Water cooled heat pump for indoors installation WSHN-EE 17-121 RANGE Nominal heating capacity (W10/W45) from 6,68 kw to 38,7 kw Nominal cooling capacity

More information

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT. Made in Italy Air Conditioning Wall-mounted Fan Coil QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction Version

More information

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor SkyStar SK Cassette Fan Coil Unit with Asynchronous Motor Innovating and beautiful design, seven different sizes, high control flexibility, easy maintenance: the SkyStar chilled water Cassette is the result

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry System System Simple and flexible direct expansion solutions for the commercial sector and industry System is the autonomous solution for climate control in small and medium shops. The cooling or thermal

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly

More information

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT TECHNICAL INSTRUCTIONS CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 6 2 pipes 6.00 kw 7.70 kw CWX 8 2 pipes 8.00 kw 10.50 kw CWX 10 2 pipes 9.92 kw 13.00 kw November 2008 10 12

More information

AHU N Range AQX. AQX Air handling units. Air flow 1, ,000 m3/h (350-44,400 l/s)

AHU N Range AQX. AQX Air handling units. Air flow 1, ,000 m3/h (350-44,400 l/s) AHU N 13.05.001 Range AQX AQX Air handling units Air flow 1,300-160,000 m3/h (350-44,400 l/s) Applications Commercial and Industrial New projects and renovation Suitable for new projects and renovations,

More information

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D REKO HEAT RECOVERY UNITS The heat recovery units making up the series REKO have been designed and built to solve the problems tied to the high energy consumption of systems that use outdoor air. A high-efficiency

More information

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax: Biddle Air Systems Limited St. Mary s Road, Nuneaton,Warwickshire CV AU. Tel: + 0 78 Fax: + 0 77 Email: sales@biddle-air.co.uk http://www.biddle-air.co.uk F.H. Biddle B.V. P. O. Box, NL-988 ZG Kootstertille,The

More information

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling TECHNICAL INSTRUCTIONS CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 3 pipes.60 3.9 pipes + electric heating.08.96 +.5 pipes.08.5 CWX 5 pipes.70 5.70 pipes + electric heating.3 5.3 +.50

More information

QTS SELECTION TECHNICAL BOOKLET

QTS SELECTION TECHNICAL BOOKLET EN QTS SELECTION TECHNICAL BOOKLET Bi2 FAN RADIATORS AND FAN COILS Italian company established in 1956 2 Bi2 Bi2 TABLE OF CONTENTS 1 Range of system terminals... 6 1.1 Cabinet system terminals... 6 1.2

More information

Air Conditioning Carisma CRS High Pressure Fan Coil Units.

Air Conditioning Carisma CRS High Pressure Fan Coil Units. Air Conditioning Carisma CRS High Pressure Fan Coil Units Quality management systems ISO 900 Cert. n 0/ www.euroventcertification.com www.certiflash.com INTRODUCTION In line with innovative trends and

More information

LOW STATIC HYDRONIC DUCTED UNIT

LOW STATIC HYDRONIC DUCTED UNIT LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity

More information

ELFOENERGY LARGE 2 TECHNICAL BULLETIN HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES

ELFOENERGY LARGE 2 TECHNICAL BULLETIN HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES TECHNICAL BULLETIN ELFOENERGY LARGE HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES Nominal cooling capacity from to kw ELFOEnergy LARGE is a highly energy efficient

More information

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...

More information

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT Made in Italy Air Conditioning High Wall Fan Coil -ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction

More information

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative

More information

technical data Fan coil unit FWB small duct unit

technical data Fan coil unit FWB small duct unit technical data Fan coil unit FWB small duct unit TABLE OF CONTENTS FWB 1. Nomenclature ---------------------------------------------------------------------- 2 2. Features -----------------------------------------------------------------------------

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE

More information

UniTrane Ductable Units D-line and B-Line

UniTrane Ductable Units D-line and B-Line UniTrane Ductable Units D-line and B-Line Discover the new UniTrane Ductable Units The ideal air-conditioning solutions for your building Air-conditioning plays an important role in the comfort level in

More information

- CONTROL - ESC HOME. 10: Display STEP: 00/00. ON Unit on OFF Unit off 15/02/03 08:03:51 SETUP 10: 12: 13: MODE MODE: no significant

- CONTROL - ESC HOME. 10: Display STEP: 00/00. ON Unit on OFF Unit off 15/02/03 08:03:51 SETUP 10: 12: 13: MODE MODE: no significant - CONTROL - MAIN CONTROL MODULE KEYPAD 1: 2: I Led = alight when unit is ON Led = extinguished when unit is OFF ON/OFF key: when pressed and held for at least 3 seconds, switches the unit on or off 3:

More information

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS

More information

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM Air Conditioning Fan Coil Units ICIM ISO 900 - Cert. n 0545/2 Unit heaters Radiant panels Fan coils Air handling units Flues SABIANA ENVIRONMENTAL COMFORT Sabiana is the fan coil that continues the Sabiana

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant Air Conditioning Ceiling Air Conditioning Elegant ISO 00 - Cert. n 0/ Unit heaters Radiant panels Fan coils Air handling units Flues SABIANA ENVIRONMENTAL COMFORT Air Conditioning SABIANA ENVIRONMENTAL

More information

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units YORK YPRE RTR/RTP SERIES Air to air packaged rooftop units Cooling

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings 0932EN October 2017 CHARACTERISTIC DATA Air flow rate [m 3 /h] 200 Pressure available (factory configuration) [Pa] 15 Moisture removed (26 C - 65% R.H. - inlet water 15 C) [l/24h] 24,7 Max. absorbed electric

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil Ducted Three Phase Packaged Air Conditioner Technical Data, 0, 180 Extra Long Life Epoxy Coated Outdoor Coil Nominal Cooling Capacity 10.0 kw 18.5 kw JUNE 5 , 0, 180 DUCTED PACKAGED ROOF TOP AIR CONDITIONERS

More information

NEW. MB control board. communication protocol. for Modbus. Air Conditioning Carisma CRSO High Pressure Fan Coil Units

NEW. MB control board. communication protocol. for Modbus. Air Conditioning Carisma CRSO High Pressure Fan Coil Units NEW MB control board for Modbus communication protocol Compliant with ERP 0 Regulation (EU) No. 7/0 Quality management systems ISO 900 Cert. n 0/ www.eurovent-certification.com www.certiflash.com Air Conditioning

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL

More information

The Sabiana. of Fan Coil

The Sabiana. of Fan Coil The Sabiana family of Fan Coil Range Basics A complete range of fan coils for use with Hot water for heating and chilled water for cooling Eurovent Certified Typical Applications Schools Hotels Commercial

More information

COMFORT HYDRONIC TERMINALS

COMFORT HYDRONIC TERMINALS COMFORT HYDRONIC TERMINALS i i-chd NEW GENERATION CASSETTE WITH EC HIGH EFFICIENCY MOTOR. CENTRIFUGAL FAN WITH CONTINUOUS AIR FLOW REGULATION AND SPEED MODULATION. ENERGY CONSUMPTION REDUCED BY MORE THAN

More information

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK NEW energy consumption ECM motors ECM Cassette Fan Coil Units www.eurovent-certification.com www.certiflash.com CONTENTS Introduction Page 3 Main components Page 4 EUROVENT Certifications Page 5 Emissions

More information

ELFOEnergy SHEEN. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XSi RANGE HIGH SEASONAL EFFICIENCY

ELFOEnergy SHEEN. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XSi RANGE HIGH SEASONAL EFFICIENCY Technical Bulletin BT17I022GB-00 ELFOEnergy SHEEN Air source inverter heat pump for outdoor installation WSAN-XSi 10.1 22.2 RANGE Nominal heating capacity (A7/W45) from 23,3 to 61 kw Nominal cooling capacity

More information

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue High wall fan coils Climmy FHW/FHW-ECM Technical Catalogue Versions and Main components MODELS WITHOUT ELECTRIC HEATER All versions are available without valves, with 2 way valve or with 3 way valve fitted

More information

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL COOLING CAPACITY FROM 20,8 TO 93,3 kw ED.X 1462 F U Kc 72 FC The range of direct expansion close

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

NEW. SkyStar SkyStar ECM. Cassette Fan Coil Units. consumption ECM motors. Low energy. Air Conditioning ENVIRONMENTAL COMFORT

NEW. SkyStar SkyStar ECM. Cassette Fan Coil Units. consumption ECM motors. Low energy. Air Conditioning ENVIRONMENTAL COMFORT NEW energy consumption ECM motors Air Conditioning ECM Cassette Fan Coil Units ISO 9001 - Cert. n 0545/4 Unit heaters Radiant panels Fan coils Air handling units Flues ENVIRONMENTAL COMFORT CONTENTS Introduction

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center Uniflair LE TDER-TUER Energy-saving units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDER) > Upflow (TUER)

More information

ELFOEnergy Extended Inverter

ELFOEnergy Extended Inverter Technical Bulletin BT14F008GB-00 ELFOEnergy Extended Inverter Air cooled inverter heat pump for outdoor installation WSAN-XIN 21-171 RANGE PREMIUM Version Nominal heating capacity (A7/W45) from 5 to 32

More information

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Quality Management Systems 30RBY/RQY 017-033 Nominal cooling capacity 15-33 kw Nominal heating capacity 17-31 kw The new

More information

SPECIFICATIONS CWC - 2P / 4P CWC 020 CWC 030 CWC 040 CWC 050 CWC 070 CWC

SPECIFICATIONS CWC - 2P / 4P CWC 020 CWC 030 CWC 040 CWC 050 CWC 070 CWC APPLICATION GUIDE CHILLED WATER CASSETTE CWC - P/4P English/03-005 INDEX Index AGU CWC-P/4P General Description Specifications Performances tables Sound levels Options Dimensions Unit installation Electrical

More information

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board SkyStar SK-ECM Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board The SkyStar SK-ECM series, available in 5 models, uses an innovative brushless synchronous permanent magnet electronic

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive,

More information

EVH SPACE TECHNICAL BULLETIN BT05L002GB-04 WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

EVH SPACE TECHNICAL BULLETIN BT05L002GB-04 WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP TECHNICL BULLETIN EVH SPCE - 1 WTER TO IR DUCTBLE INDOOR HORIZONTL HET PUMP The EVH SPCE single-compressor units are available in sizes, with a complete series of accessories and feature very high efficiency

More information

Technical. Catalogue. NA Version PDWL AECM. LSTAT Series Hydronic EC Ducted Fan Coil

Technical. Catalogue. NA Version PDWL AECM. LSTAT Series Hydronic EC Ducted Fan Coil MDL SOLUTIONS Technical Catalogue NA Version PDWL AECM LSTAT Series Hydronic EC Ducted Fan Coil Hydronic Fan Coil Platform Introduction Company Introduction HVAC Solutions Sonkor Global MDL SOLUTIONS Technical

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

CHAPTER 6 CONDENSING UNITS

CHAPTER 6 CONDENSING UNITS CHAPTER CONDENSING UNITS Unit Page MHA/K - MHA/K 8 0 - MRA/K 8-9 MRA/K 8 0 0 - FROM, KW TO KW. MHA/K AIRCOOLED CONDENSING UNITS AND REVERSIBLE CONDENSING UNITS WITH AXIAL FANS AND ROTARY/SCROLL COMPRESSOR.

More information

SIGMA PRISMA LOW BODY CONCEALED

SIGMA PRISMA LOW BODY CONCEALED EN SIGMA PRISMA LOW BODY CONCEALED EST EST (Energy Saving Technology) is applied to the EURAPO fan coil units and cassette units. It permits to obtain extremely low electrical absorption and a continuous

More information

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT EEDEN08-424 technical data Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT EEDEN08-424 technical data Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT Fan coil units 1 Hydronic Systems Fan coil units 1 F

More information

Energy. The Energy ducted units have been designed. Heat Recovery Unit

Energy. The Energy ducted units have been designed. Heat Recovery Unit Energy Heat Recovery Unit The Energy ducted units have been designed to allow energy savings in the ventilation systems of public and private environments, such as bars, restaurants, offices, shops, etc.,

More information

GHE Dehumidifiers for radiant cooling systems with heat recovery

GHE Dehumidifiers for radiant cooling systems with heat recovery Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

Application guide Installation, operating and maintenance manual AIRCUBE - KSCM/KSHM. Providing indoor climate comfort

Application guide Installation, operating and maintenance manual AIRCUBE - KSCM/KSHM. Providing indoor climate comfort Application guide Installation, operating and maintenance manual AIRCUBE - Providing indoor climate comfort MIL84E-0607 07-2007 Congratulations you have made a wise choice and we feel sure that it will

More information

FAN COIL UNITS LASER / LOW BODY / CONCEALED

FAN COIL UNITS LASER / LOW BODY / CONCEALED SAPHIR TECHNICAL LITERATURE FAN COIL UNITS LASER / LOW BODY / CONCEALED Energy Saving Technology EST (Energy Saving Technology) is applied to the Johnson Controls fan coil units and cassette units. It

More information

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SERIES: WCHZ MODELS: 201, 251, 271, 351, 401, 501, 701, 721, 751 COOLING CAPACITIES OF: 6,4

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding

More information