WSAN-XEE AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION

Size: px
Start display at page:

Download "WSAN-XEE AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION"

Transcription

1 A WSAN-XEE 2-02 AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION CLASS ENERGY EFFICIENCY IN CLASS A Reduced energy consumption Optimised operation at partial loads Complete hydronic assembly supplied as standard WSAN-XEE (R-4A) Size Cooling Heating [kw] [kw] REPLACE: BT0F009GB-04 The ELFOENERGY series chillers represent an important stage in the development of this type of unit. They feature the most up-to-date advances in technology, standing out for: EFFICIENCY thanks to its special construction, the ELFOENERGY ensures high energy efficiency, in particular during operation at partial loads; SELF-ADAPTING the evolved electronics implemented adapt the operating parameters of the chiller to the load conditions of the system it is installed in, optimising consumption, efficiency and the working life of the components; EASE OF INSTALLATION each unit is supplied as standard with a complete hydronic assembly and is completely tested in the factory; installation is consequently quick and easy. BT0F009GB-05 Clivet is partecipating in the EUROVENT Certification Programme "Liquid Chilling Packages". Products are listed in the EUROVENT Directory of Certified Products and in the site Eurovent Chillers Certification Programme covers air cooled packaged chillers up to 600 kw and water cooled packaged chillers up to 1500 kw. CERTIFIED QUALITY SYSTEM UNI EN ISO 9001:200

2 Percentage of operating time BT0F009GB-05 Load requested to the unit COMFORT IS A HUMAN RIGHT. CARE FOR THE ENVIRONMENT IS A HUMAN DUTY. The ELFOENERGY is an appliance of new conception, designed especially to operate with increasing efficiency as thermal load reduces, yet able to handle the maximum load demand whenever necessary. Because of significant diurnal and seasonal variations in load, chillers must operate for prolonged periods under partial load conditions. A ELFOENERGY unit always ensures conditions of maximum comfort coupled with ultra high efficiency for most of the system s working life, which means a big saving in electrical energy. This reflects the corporate policy of CLIVET, namely: offering fundamental and concrete solutions to help safeguard the well -being of people and their environment. By way of example, here is a seasonal thermal load graph relating to a multi-use building (shops, offices and apartments) located in the Milan area. SEASONAL THERMAL LOAD March April May June July August September October MULTIPLE HIGH EFFICIENCY SCROLL COMPRESSORS IN THE SAME COOLING CIRCUIT compressor Single coil A key aspect of the approach adopted in designing the ELFOENERGY is the notion of equipping a single cooling circuit with a battery of SCROLL compressors, rather than the conventional separated circuit. Moreover the use of compressors with different capacities allows a rise of the capacity step number and in this way a better capacity-control flexibility. This enables the unit to adapt perfectly to the system load. The evolved control equipment used with ELFOENERGY units will optimize the activation sequence and balance the operating cycles of the compressors to maximum advantage compressor Evaporator EUROVENT ENERGY EFFICIENCY CLASSIFICATON CLASS A IN HEATING MODE ELFOENERGY XEE units have been studied to obtain the highest ENERGY EFFICIENCY also in full load condition. For the heating operation, the ELFOENERGY R-4A is in Eurovent energy efficiency classification class "A" A CLASS HIGH EFFICIENCY AT PARTIAL LOADS The unit in an air-conditioning system is selected on the basis of the maximum load the system is designed to handle. In practice however, maximum load conditions account only for a small percentage of the overall operating time, whereas the partial load operation is the true condition in which the unit had to operate. Simulation tests conducted in different buildings have shown that systems operate on average for 90% of total operating time with thermal load lower than 60%. Accordingly, operating efficiency under partial load conditions is a key consideration when selecting a chiller. For 60% of the time, load is less than 0% For 90% of the time, load is less than 60% 2 Load percentage

3 Electrical energy (kwh) ELFOEnergy - medium EER EER monthly comparison Standard Unit - medium EER The electronic controller and the specific constructional configuration highlight the thermodynamic efficiency of ELFOENERGY. To achieve maximum efficiency, the electronic controller starts the compressors according to the most favourable ratio between the exchange surfaces, so that the condensing and evaporation temperature are always the most advantageous. The diagram to the side shows the trend in efficiency (EER) of an ELFOENERGY unit and of a traditional unit on a typical summer day. It is clear how the efficiency of the ELFOENERGY is practically always higher, reaching values that are even more than twice as high at some times of the day, when the load thermal is lower. October September August July June May April March LOW OPERATING COSTS Thanks to the characteristics described previously, ELFOEnergy ensures much higher efficiency than a traditional chiller for most of the operating time. Comparing, in the same system, the power consumption of the ELFOENERGY against the power consumption of a traditional chiller with the same capacity, the seasonal savings can reach around 5%. These data, combined with the intrinsic reliability of the unit, make the ELFOENERGY an essential option in both terms of pay back time and peace of mind. Electrical energy weekly consumptions (for a office building in Milan) Traditional unit March April May June July August September October In a system with a 4 kw unit installed, the annual energy saving obtained with a ELFOENERGY is in the region of.000 kwh, which signifies a cost saving of 500 and 590 kg less fuel to transport and burn. NOISE TOO IS LOAD-DEPENDENT The condenser electronic controller, fitted as standard on all the ELFOENERGY units, automatically adjusts the fan speed as the thermal load decreases. As the fans are the greatest source of noise for this type of unit, it is clear how this feature brings important benefits, in particular at night, when the load is reduced but noise sensitivity is heightened.

4 SLIDING TEMPERATURE The elctronic adjustment of ELFOENERGY enables to suit the temperature of the water generated by the unit to the load conditions detected by system according to a SLIDING TEMPERATURE concept that searches for the best balance between power to be supplied and energy spent to produce it. A special measure in the refrigerating circuit prevents ice from forming in the base of the air exchanger. ALL-IN-ONE PHILOSOPHY ELFOEnergy is a unit "ready for use", including not only the components of the refrigerant circuit, but also a water circuit complete with pump (optional double pump), expansion vessel, safety valve, filling assembly and filter. As a result, the only requirement is to connect the unit to the water inlet and outlet pipes; in this way, the commissioning times and the possible problems during installation are reduced to the minimum. Controls keyboard WATER FILTER Water filter (external installation) steel mesh mechanical filter positioned at the exchanger inlet. Suitable for filtering water and trapping the impurities present in the water circuit. Mechanic steal-mesh filter is supplied standard on units with hydronic kit N 1 PUMP with standard, reduced or larger discharge head DOUBLE PUMP (otional) with standard, reduced or larger discharge head Expansion vessel 4

5 STANDARD UNIT SPECIFICATIONS COMPRESSOR Hermetic orbiting scroll compressor complete with motor over-temperature and over-current devices and protection against excessive gas discharge temperature. Fitted on rubber antivibration mounts and complete with oil charge A oil heater is automatically switched on at the compressor shut-down to prevent oil dilution by the refrigerant. STRUCTURE Structure made from "aluzink" plate, providing excellent mechanical characteristics and extensive corrosion strength PANELLING External panels in prepainted aluminium especially indicated in outdoor installation due to its superior resistance to corrosion avoiding periodic painting. Side panels are easily removable and allow complete access to unit components. Internal sound proof lining reduces sound pressure levels. INTERNAL EXCHANGER Direct expansion heat exchanger, braze-welded AISI 16 stainless steel plates with large exchange surface and complete with external heat and anticondensate insulation. The exchanger comes complete with: - differential pressure switch, water side - antifreeze heater to protect the water side exchanger, preventing the formation of frost if the water temperature falls below a set value. EXTERNAL EXCHANGER Heat exchange coil with aluminium fins and copper tubes in staggered rows. The coils are complete with integral subcooling circuit which assures the correct refrigerant feeding of the expansion valve. Available in different options as per optional list. FAN Low speed axial fan directly driven by single phase external rotor motor with incorporated thermal overload. Housed in aerodynamically shaped enclosures to increase the efficiency and reduce the noise level. Complete with fan guard in order to help against fortuitous contact with the blades. REFRIGERANT CIRCUIT The circuit is complete with: - filter dryer - Ice Protection System: system to prevent ice on the bottom of air coil - sight glass with moisture indicator - high pressure switch - low pressure switch - liquid receiver - compressor suction shut-off valve - compressor discharge shut-off valve - high pressure safety - thermostatic expansion valve with equalizer - 4-way reverse cycle valve - non-return valve - pressure probes - antifreeze protection - Compressor timer / operation signal LED - possibility of communication with ZONE MASTER system (optional) - proportional + integral water temperature control - set point compensation with outside temperature probe - relay for remote cumulative fault signal - self-diagnosis system with immediate display of the error code - ON/OFF and alarm reset buttons - UP and DOWN buttons to increase and decrease the values - display of the set values, the error codes and the parameter index - compressor operating hour display - remote ON/OFF control - water pump control - function and command buttons - set point compensation with 4-20 ma signal HYDRAULIC CIRCUIT - water side safety valve - diaphragm expansion vessel - impurity trap with filter - Centrifugal pump - antifreeze heater protection to pumping station - drain valve - Closed couple pumps with high efficiency impellers. Maximum operating pressure 00 kpa. Temperature range from - to +0 C. Maximum glycol concentration 40%. Motor: closed type. External ventilation. Protection IP55. Insulation class F. Clockwise rotation looking at the pump from the motor side. ACCESSORIES - copper / aluminium condenser coils with Fin Guard (Silver) treatment - copper / aluminium condenser coils with acrylic lining - copper / copper condenser coils - stainless steel mesh mechanical filter (to be used, if required, with unit configured without hydronic group) - finned coil protection grill. - Storage tank - pump for useful heads other than standard - unit without hydraulic circuit components - double chilled water pump - serial communication module to supervisor (MODBUS) - set point compensation according to the outside enthalpy - daily and weekly programming clock - high and low pressure gauges - control keypad for remote installation that repeats all the functions already present on the onboard microprocessor control. - phase monitor to check the presence and correct sequence of the power supply phases - humidity probe for summer set point compensation according to the outside enthalpy and defrosting optimization in winter operation - rubber antivibration mounts ELECTRICAL PANEL The Power Section includes: - isolating transformer for auxiliary circuit power supply - main line isolator switch - compressor overload cutout switch - fan fuses - centrifugal pump motor protector - compressor control contactor - pump control contactor - phase cutting fan speed controller (pressure) The control section includes: - display of the set values and the error codes - H2o antifreeze and high refrigerant gas pressure pre-alarm function that reduces cooling capacity to avoid unit shut-down - compressor overload protection and timer 5

6 Size CONFIGURATION CODE ( 1 ) ( 2 ) ( ) ( 4 ) ( 5 ) ( 6 ) ( ) ( ) ( 9 ) ( ) WSAN-XEE S 2 400TN 1PUS S (Standard) 2 400TN 1PUS (Standard) - (Standard) OHP (Standard) - (Standard) - (Standard) - (Standard) - (Standard) - (Standard) B 2 1PUR D OHO CCCC SFSTR4N CLS PFCP ACC1 DSPB 2 1PUM CCCA 162 2PUS CCCA1 12 2PUR 222 2PUM (1) Standard Version(S) Standard (ST) (1) LOW TEMPERATURE Water low temperature(b) this version allows unit operation in the range of water and glycol mix temperatures between +4 and - C Low temperature: not required(-) (1) DOUBLE SET POINT Double set point: not required(-) Double set point for water low temperature(dspb) double set point with units in "Brine" version (2) VOLTAGE Supply voltage 400//50+N(400TN) () GROUP UTILITY SIDE Standard pump(1pus) single-pump with reduced available head(1pur) single-pump with larger available head(1pum) standard double pump(2pus) double pump with reduced available head(2pur) double pump with larger available head(2pum) Hydronic group utility side: not required(-) (4) ENERGY RECOVERY Energy recovery: not required(-) Partial energy recovery(d) made using plate exchangers to recover the desuperheating heat, up to 25% of the total heat of the unit. (5) OPERATION Operation in heat pump (OHP) Unit with heating and cooling mode standard Heat-only function (OHO) Unità in solo riscaldamento (6) CONDENSING COIL Standard condenser coil(ccs) Copper /copper condenser coil(cccc) Copper / aluminium condenser coil with acrylic lining(ccca) Copper / aluminium condenser coil with Fin Guard treatment (Silver) (CCCA1) () SOFT STARTER Disposal for inrush current reduction: not required(-) disposal for inrush current reduction, for unit 400//50+N(SFSTR4N) disposal for inrush current reduction, for unit 400//50+N () FREE CONTACTS HEATING EXTERNAL SIGNAL Additional free contacts: not required(-) free contacts for alarm(clse) free contacts for alarm (9) POWER FACTOR CORRECTION CAPACITORS (COSFI > 0.9) Power factor correction capacitors: not required(-) power factor correction capacitors (cosfi > 0.9)(PFCP) power factor correction capacitors (cosfi > 0.9) () STORAGE TANK Storage tank: not required(-) Teflon steel storage device(acc1) SOUND LEVELS Sound Power Level (db) Octave band (Hz) Sound pressure level Sound power level db(a) db(a) Measures according to ISO 44 regulations, with respect to the EUROVENT /1 certification. the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refers to a distance of 1m from the external surface of the units operating in an open field. data referred to the following conditions : internal exchanger water = / C 6

7 DP (kpa) INTERNAL EXCHANGER PRESSURE DROP EXCHANGER PRESSURE DROP LIMIT. WARNING: DON'T USE OVER THIS LIMIT UNIT WITHOUT HYDRAULIC CIRCUIT COMPONENTS Q[L/S]= WATER-FLOW RATE DP = PRESSURE DROP ,0 1,5 2,0 2,5,0,5 4,0 4,5 5,0 Q (l/s) EXCHAMGER PRESSURE DROP LIMIT. WARNING: DON'T USE BELOW THIS LIMIT. Size Minimum flow [l/s] Maximum flow [l/s] CORRECTION FACTOR FOR ANTIFREEZE SOLUTIONS % ethylene glycol by weight 5% % 15% 20% 25% 0% 5% 40% Freezing temperature C Safety temperature C Cooling Capacity Factor Nr Compressor input Factor Nr Internal exchanger Glycol solution flow Factor Nr Pressure drop Factor Nr The correction factors shown refer to water and glycol ethylene mixes used to prevent the formation of frost on the exchangers in the water circuit during inactivity in winter. FOULING CORRECTION FACTOR INTERNAL EXCHANGER m² C/W F1 FK x ^(-4) x ^(-4) x ^(-4) The cooling performance values provided in the tables are based on the external exchanger having clean plates (fouling factor 1). For different fouling factor values, multiply the performance by the coefficients shown in the table. F1 = Cooling capacity correction factors FK1 = Compressor power input correction factor INTEGRATED HEATING CAPACITIES Anternal exchanger inlet air temperature C ( D.B.) -5 / / /.9 OTHERS Heating capacity multiplication coefficient To obtain the integrated heating capacities (the real heating capacity considering the defrost cycles too), multiply the kwt value in the heating performance tables by the following coefficient.

8 DP (kpa) DP (kpa) DP (kpa) PUMP PERFORMANCE curve of discharge head with standard pump (pump + water filter) THE HEADS ARE INTENDED AS AVAILABLE AT THE UNIT CONNECTIONS Q[L/S]= WATER-FLOW RATE DP[KPA]=USEFUL DISCHARGE HEAD Q (l/s) curve of discharge head with larger pump (pump + water filter) HEAD - FLOW DIAGRAM DP = AVAILABLE HEAD Q = WATER FLOW Q (l/s) pressure drop curves double pump Q (l/s) PRESSURE DROP TO REMOVE IN THE ACCES- SORY SELECTION: DOUBLE PUMP. BOTH PUMPS CAN HAVE A STANDARD, REDU- CED OR LARGER AVAILABLE HEAD. THE SECOND PUMP STARTS UP AUTOMATICALLY IN CASE OF THE FIRST PUMP FAILURE. THE UNIT CONTROL ALLOWS AN OPERATION ROTATION OF BOTH PUMPS. THE AVAILABLE HEAD, IN CASE OF THE DOUBLE PUMP USE, IS THE AVAILABLE HEAD OF THE SINGLE CHOOSEN PUMP (STANDARD, REDUCED OR LARGER) LESS THE PRESSURE DROPS AS YOU CAN SEE FROM THE GRAPH.

9 Application: Terminal units GENERAL TECHNICAL SPECIFICATIONS Size COOLING Cooling capacity 1 kw Compressor power input 1 kw Total power input 2 kw EER EER EER EER ESEER HEATING Heat output kw Compressor power input kw Total power input 2 kw COP COMPRESSOR Type of compressors SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL No. of Compressors Nr Std Capacity control steps Nr 2 2 Oil charge (C1) l Refrigerant circuits Nr INTERNAL EXCHANGER Type of internal exchanger PHE PHE PHE PHE PHE PHE PHE PHE No. of internal exchangers Nr Water flow rate (Internal Exchanger) 1 l/s Max water flow-rate l/s internal exchanger pressure drop kpa Useful pump discharge head 1 kpa EXTERNAL SECTION FANS Type of fans 9 AX AX AX AX AX AX AX AX Number of fans Nr Standard air flow l/s Installed unit power kw CONNECTIONS Water fittings 1" 1/4 1" 1/4 1" 1/4 2" 2" 2" 2" 2" HYDRAULIC CIRCUIT Max water side pressure kpa Safety valve calibration kpa EXPANSION VESSEL Expansion vessel capacity l Maximum water side pressure kpa No. of expansion vessels Nr POWER SUPPLY Standard power supply V 400//50+N 400//50+N 400//50+N 400//50+N 400//50+N 400//50+N 400//50+N 400//50+N NOISE LEVELS Sound pressure level (1 m) db(a) DIMENSIONS Length mm Depth mm Height mm Packing volume m STANDARD UNIT WEIGHTS Shipping weight kg Operating weight kg (1) data referred to the following conditions : internal exchanger water = / C external exchanger air intake 5 C (2) Total absorbed power is given by the compressor absorbed power + fan absorbed power + auxiliary circuit absorbed power. () 0% EER internal exchanger water outlet temperature = C room temperature = 5 C (4) EER 40% data referred to the following conditions : internal exchanger water outlet temperature = 1 C room temperature = 25 C (5) 50% EER data referred to the following conditions : internal exchanger water outlet temperature = C room temperature = 2 C (6) EER 60% data referred to the following conditions : internal exchanger water outlet temperature = C room temperature = 2 C () data referred to the following conditions : outlet water internal exchanger 45 C room temperature = C (RH = 5%) () PHE = plates (9) AX = axial-flow fan 9

10 GENERAL TECHNICAL SPECIFICATIONS Application: Unit for underfloor heating Size COOLING Cooling capacity 1 kw Compressor power input 1 kw Total power input 2 kw EER HEATING Heat output kw Compressor power input kw Total power input kw COP COMPRESSOR Type of compressors SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL SCROLL No. of Compressors Nr Std Capacity control steps Nr 2 2 Oil charge (C1) l Refrigerant circuits Nr INTERNAL EXCHANGER Type of internal exchanger 4 PHE PHE PHE PHE PHE PHE PHE PHE Water flow rate (Internal Exchanger) l/s Max water flow-rate l/s internal exchanger pressure drop 1 kpa Useful pump discharge head 1 kpa EXTERNAL SECTION FANS Type of fans 5 AX AX AX AX AX AX AX AX Number of fans Nr Standard air flow l/s Installed unit power kw CONNECTIONS Water fittings 1" 1/4 1" 1/4 1" 1/4 2" 2" 2" 2" 2" HYDRAULIC CIRCUIT Max water side pressure kpa Safety valve calibration kpa EXPANSION VESSEL Expansion vessel capacity l Maximum water side pressure kpa No. of expansion vessels Nr POWER SUPPLY Standard power supply V 400//50+N 400//50+N 400//50+N 400//50+N 400//50+N 400//50+N 400//50+N 400//50+N NOISE LEVELS Sound pressure level (1 m) db(a) DIMENSIONS Length mm Depth mm Height mm Packing volume m STANDARD UNIT WEIGHTS Shipping weight kg Operating weight kg (1) data referred to the following conditions : internal exchanger water = 2/1 C external exchanger air intake 5 C (2) Total absorbed power is given by the compressor absorbed power + fan absorbed power + auxiliary circuit absorbed power. () data referred to the following conditions : water to internal exchanger 0/5 C outdoor air temperature C DB - 6 C WB (4) PHE = plates (5) AX = axial-flow fan Voltage: 400//50+N ELECTRICAL DATA Size F.L.A. - FULL LOAD CURRENT AT MAX ADMISSIBLE CONDITIONS F.L.A. - Pump A F.L.A. - Total A F.L.I. FULL LOAD POWER INPUT AT MAX ADMISSIBLE CONDITION F.L.I. - Pump kw F.L.I. - Total kw M.I.C. MAXIMUM INRUSH CURRENT M.I.C. - Value A voltage unbalance: max 2 % power supply 400//50 (+ NEUTRAL) +/- 6% The pump is included in the total values calculation for non standard voltage please contact Clivet technical office

11 Application: Terminal units OPERATING LIMITS (COOLING) Size EXTERNAL EXCHANGER Max air intake temperature 1 C Max air intake temperature 2 C Min. air intake temperature C INTERNAL EXCHANGER Max water inlet temperature 4 C Min. water outlet temperature 5 C Min. water outlet temperature 6 C OPERATING LIMITS (HEATING) EXTERNAL EXCHANGER Max air temperature inlet (WB) C Min air inlet temperature (W.B.) C INTERNAL EXCHANGER Min. water outlet temperature C Max water outlet temperature 9 C Warning: the still air condition is meant as absence of air flow to the unit. Any wind condition can let air pass through the condenser coil thus worsening the operating limits of the unit (see limits with air speed at 0,5 m/s & 1 m/s). ATTENTION: IN CASE OF PREDOMINANT WINDS, WINDBREAK BARRIERS ARE NECESSARY. Water thermal head (min / max) are indicated in the section INTERNAL EXCHANGER PRESSURE DROP (1) unit at full load: internal exchanger water / C (2) internal exchanger water = / C capacity-controlled unit (automatic capacity control) () external exchanger air in quiet (4) this limit can be exceeded for brief and transitory periods with automatic capacity control of the unit: the maximum limit is 0 C. (5) standard unit outdoor air temperature 5 C (6) B = Low Temperature outdoor air temperature 5 C Fluid with ethylene glycol of 40% () unit at full load outlet water internal exchanger 45 C () outlet water internal exchanger 45 C (9) room temperature = C (RH = 5%) Application: Unit for underfloor heating OPERATING LIMITS (COOLING) Size EXTERNAL EXCHANGER Max air intake temperature 1 C Max air intake temperature 2 C Min. air intake temperature C INTERNAL EXCHANGER Max water inlet temperature 4 C Min. water outlet temperature 5 C Min. water outlet temperature 6 C OPERATING LIMITS (HEATING) EXTERNAL EXCHANGER Max air temperature inlet (WB) C Min air inlet temperature (W.B.) C INTERNAL EXCHANGER Min. water outlet temperature C Max water outlet temperature C (1) unit at full load internal exchanger water = 2/1 C (2) internal exchanger water = 2/1 C capacity-controlled unit (automatic capacity control) () external exchanger air in quiet (4) this limit can be exceeded for brief and transitory periods with automatic capacity control of the unit: the maximum limit is 0 C. (5) standard unit outdoor air temperature 5 C (6) B = Low Temperature outdoor air temperature 5 C Fluid with ethylene glycol of 40% () unit at full load exchanger water outlet 5 C () exchanger water outlet 5 C 11

12 APPLICATION: TERMINAL UNITS COOLING PERFORMANCE Size To (ºC) EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe To = Internal exchanger water outlet temperature in C kwf = Cooling capacity in kw kwe = Compressor power input in kw Performances in function of the inlet/outlet water temperature differential = 5 C

13 APPLICATION: TERMINAL UNITS COOLING PERFORMANCE Size To (ºC) EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe To = Internal exchanger water outlet temperature in C kwf = Cooling capacity in kw kwe = Compressor power input in kw Performances in function of the inlet/outlet water temperature differential = 5 C 1

14 APPLICATION: TERMINAL UNITS APPLICATION: UNIT FOR UNDERFLOOR HEATING HEATING PERFORMANCE Size Ta ( C) DB/WB EXTERNAL EXCHANGER WATER OUTLET TEMPERATURE ( C) kwt kwe kwt kwe kwt kwe kwt kwe kwt kwe kwt kwe / / / /.9 / 6 /.2 15 / 1 - / / / /.9 / 6 /.2 15 / 1 - / / / /.9 / 6 /.2 15 / 1 - / / / /.9 / 6 /.2 15 / 1 - / / / /.9 / 6 /.2 15 / 1 - / / / /.9 / 6 /.2 15 / Ta = internal exchanger inlet air temperature kwt = Heating capacity (kw) kwe = Compressor power input in kw 14

15 APPLICATION: TERMINAL UNITS APPLICATION: UNIT FOR UNDERFLOOR HEATING HEATING PERFORMANCE Size Ta ( C) DB/WB EXTERNAL EXCHANGER WATER OUTLET TEMPERATURE ( C) kwt kwe kwt kwe kwt kwe kwt kwe kwt kwe kwt kwe / / / /.9 / 6 /.2 15 / 1 - / / / /.9 / 6 /.2 15 / Ta = internal exchanger inlet air temperature kwt = Heating capacity (kw) kwe = Compressor power input in kw 15

16 APPLICATION: UNIT FOR UNDERFLOOR HEATING COOLING PERFORMANCE Size To (ºC) EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe To = Internal exchanger water outlet temperature in C kwf = Cooling capacity in kw kwe = Compressor power input in kw Performances in function of the inlet/outlet water temperature differential = 5 C 16

17 APPLICATION: UNIT FOR UNDERFLOOR HEATING COOLING PERFORMANCE Size To (ºC) EXTERNAL EXCHANGER AIR INTAKE TEMPERATURE (ºC) kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe kwf kwe To = Internal exchanger water outlet temperature in C kwf = Cooling capacity in kw kwe = Compressor power input in kw Performances in function of the inlet/outlet water temperature differential = 5 C 1

18 (OHP)Unit with heating and cooling mode Standard configuration of unit with heating and cooling mode (OHO)Heat-only function Unit configuration in heating-only mode (CCCA1)copper / aluminium condenser coils with Fin Guard (Silver) treatment The Fin Guard Silver, for finned exchanger, is a polyurethane vernish waterproof (for waterworks, see and discharge water). It is also resistant to oil products and other different solvents. It hasn't any effects on the air side pressure drops. (CCCC)copper / copper condenser coils The copper/copper condensing coil allows a better resistence to the natural agent like salt and sulphureous vapours. (CCCA)copper / aluminium condenser coils with acrylic lining The copper/aluminium evaporator coils with acrylic lining can be used in the room where the ambient air contains a concentration of salt and other not very aggressive agents. (-)unit without hydronic assembly The unit can be requested without circulating pump, expansion vessel, safety valve water side and filling assembly. (1PUR)Single pump with reduced working head (1PUM)Single pump with increased working head (2PUS)standard double pump (2PUR)Double pump with reduced working head (2PUM)Double pump with increased working head 1

19 +5V CN2 16 gnd CN1 CN CN1 gnd + - V AC (PMX)phase monitor phase monitor to check the presence and correct sequence of the power supply phases separately supplied accessories (SFSTR4N)disposal for inrush current reduction, for unit 400//50+N Starting up a motor directly can overload the electricity network, with start-up currents up to times the nominal current. Thanks to the breakaway current reduction device, start-up takes place gradually, with the start-up current being limited during this period of time. The start-up current can therefore be reduced to.5-4 times the nominal current, meaning that the power systems and protection devices can be sized with lower parameters. (CMMBX)serial communication module to supervisor (MODBUS) The serial communication module to supervisor (MODBUS) is connected with the principal module through a comb connection (see lay-out on electrical panel). In this way the remote assistance and supervision are available through standard MODBUS protocol.it is possible to connect to a single supervisor system up to units. The connection to PC must be obtained through a converter RS45/22; the serial port RS22 admits as maximum a m length.the serial communication module to supervisor (MODBUS) is necessary when the unit is connected to ELFOCONTROL. SERIALE TTL / RS45 Vac - + gnd Supervisore TTL / RS45 gnd V AC RS-22 gnd RS-45 TTL / RS45 gnd V AC ALLE ALTRE UNITA separately supplied accessories (SCPX)Set point compensation with according to outdoor enthalpy It allows to modulate unit set-point according to the external enthalpy. In this way an higher comfort and continuous energy saving are guaranteed. It optimizes unit energy efficiency, through a set point automatic modulation, according to the external conditions (temperature + humidity). It optimiezs also the defrosting time during winter operation. separately supplied accessories 19

20 (AMRX)Rubber antivibration mounts The rubber antivibration mounts reduce the vibrations of compressor during its operation and they are installed at the base toe. separately supplied accessories (CLS)free contacts for alarm Free contacts for compressor state (PFCP)power factor correction capacitors (cosfi > 0.9) the power factor correction capacitors increase the cosf value, reducing the apparent current on the supply line to the chiller assembly (RCMRX)Remote control with remote microprocessor control the remote control allows the remote display and operation of functions of the microprocessor on the unit separately supplied accessories (ACC1)Storage Inertial storage tank of 0 litres, for applications where the system has limited water content. (sizes 2-2-2) Inertial storage tank of 0 litres, for applications where the system has limited water content. (sizes ) (IFWX)Steel mesh filter on the water side stainless steel mesh mechanical filter (to be used, if required, with unit configured without hydronic group) steel mesh mechanical filter positioned at the exchanger inlet. Suitable for filtering water and trapping the impurities present in the water circuit. separately supplied accessories (D)Energy recovery partial recovery of condensing heat, up to 25% 20

21 (14) 60 O P (14) 1 09 DIMENSIONAL DRAWING DIMENSIONALES AND WEIGHT DISTRIBUTION WSAN-XEE (15) W1 W "G" 1 2 W W4 00 (15) M N Size M mm N mm O mm P mm Length mm Depth mm Height mm W1 kg W2 kg W kg 90 4 W4 kg 66 6 Operating weight kg Shipping weight kg (1) COMPRESSOR (2) FINNED EXCHANGER () HELICAL FANS (4) PLATE EXCHANGER (5) EXCHANGER WATER OUTLET (6) EXCHANGER WATER INLET () PUMP () POWER INPUT (9) LIFTING HOLES () ELECTRICAL PANEL (11) MICROPROCESSOR KEYBOARD () MAIN ISOLATOR SWITCH (1) VIBRATION MOUNTS POSITION (14) MINIMUM DIMENSION FOR A PROPER AIR FLOW TO THE CONDENSER COIL. (15) MINIMUM DIMENSION FOR A SAFE PASSAGE. (G) BARYCENTRE VICTAULIC CONNECTION JOINTS 21

22 (14) O P 00 (14) DIMENSIONAL DRAWING DIMENSIONALS AND WEIGHT DISTRIBUTION WSAN-XEE (15) W1 W "G" 1 2 W W4 00 (15) M N Size M mm 92 9 N mm O mm P mm Length mm Depth mm Height mm W1 kg W2 kg W kg W4 kg Operating weight kg Shipping weight kg (1) COMPRESSOR (2) FINNED EXCHANGER () HELICAL FANS (4) PLATE EXCHANGER (5) EXCHANGER WATER INLET (6) EXCHANGER WATER OUTLET () PUMP () POWER INPUT (9) LIFTING HOLES () ELECTRICAL PANEL (11) MICROPROCESSOR KEYBOARD () MAIN ISOLATOR SWITCH (1) VIBRATION MOUNTS POSITION (14) MINIMUM DIMENSION FOR A PROPER AIR FLOW TO THE CONDENSER COIL. (15) MINIMUM DIMENSION FOR A SAFE PASSAGE. (G) BARYCENTRE VICTAULIC CONNECTION JOINTS 22

23 (14) O P 00 (14) DIMENSIONAL DRAWING DIMENSIONALS AND WEIGHT DISTRIBUTION WSAN-XEE (15) W1 W "G" 1 2 W W4 00 (15) M N Size M mm N mm 2 2 O mm P mm 55 5 Length mm Depth mm Height mm W1 kg W2 kg 11 W kg W4 kg Operating weight kg Shipping weight kg (1) COMPRESSOR (2) FINNED EXCHANGER () HELICAL FANS (4) PLATE EXCHANGER (5) EXCHANGER WATER INLET (6) EXCHANGER WATER OUTLET () PUMP () POWER INPUT (9) LIFTING HOLES () ELECTRICAL PANEL (11) MICROPROCESSOR KEYBOARD () MAIN ISOLATOR SWITCH (1) VIBRATION MOUNTS POSITION (14) MINIMUM DIMENSION FOR A PROPER AIR FLOW TO THE CONDENSER COIL. (15) MINIMUM DIMENSION FOR A SAFE PASSAGE. (G) BARYCENTRE VICTAULIC CONNECTION JOINTS 2

24 CLIVET SPA Feltre (BL) ITALY Tel Fax info@clivet.it CLIVET ESPAÑA S.A. Madrid - SPAIN Tel Fax info@clivet.es CLIVET UK LTD Fareham (Hampshire) U.K. Tel (0) Fax + 44 (0) info@clivet-uk.co.uk CLIVET NEDERLAND B.V. Amersfoort - Netherlands Tel. + 1 (0) Fax + 1 (0) info@clivet.nl CLIVET SPA BUREAU DE LIAISON EN FRANCE Verrierès le Buisson - FRANCE Tel. + (0) Fax + (0) info.fr@clivet.com CLIVET GmbH Norderstedt - GERMANY Tel. +49 (0) Fax +49 (0) info.de@clivet.com CLIVET TFAIR SYSTEMS (P)LTD. Malur - INDIA Tel /5 Fax info@clivettfa.com The data contained in this bulletin is not binding and may be changed by the manufacturer without prior notice. All reproduction, even partial, is prohibited. Copyright - CLIVET S.p.A. - Feltre (BL) - Italy

AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION. Size

AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION. Size BT0B00GB-04 ELFO ENERGY COMPACT AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION Ultra-compact. Top noiselessness. Variable flow-rate circulator. Reduced energy consumption. WSAN-EE (R-4A) Size Cooling

More information

WSAT-EE AIR COOLED WATER CHILLER FOR OUTDOOR INSTALLATION

WSAT-EE AIR COOLED WATER CHILLER FOR OUTDOOR INSTALLATION BT0B00GB-02 - WSAT-EE - AIR COOLED WATER CHILLER FOR OUTDOOR INSTALLATION Ultra-compact. Top noiselessness. Variable flow-rate circulator. Reduced energy consumption. WSAT-EE - (R-4A) Size Cooling [kw]

More information

VULCAN AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION

VULCAN AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION VULCAN AIR TO WATER HEAT PUMP FOR OUTDOOR INSTALLATION Operation only in heating Operation up to -18 C Reduced energy consumption Water production from 60 C to -10 C external air *Due to its high efficiency,

More information

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP EVH R-407C WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP Size Cooling Heating [kw] [kw] 7 2.0 1.9 11 2.6 2.5 15 3.9 3.3 5.2 5.5 25 7.3 6.7 31 8.9 8.4 41 10.7 9.8 REPLACE: BT02E009GB-01 The Versatemp

More information

ELFOEnergy Ground. Technical Bulletin. Water cooled heat pump for indoors installation WSHN-EE RANGE

ELFOEnergy Ground. Technical Bulletin. Water cooled heat pump for indoors installation WSHN-EE RANGE Technical Bulletin BT06C002GB-11 ELFOEnergy Ground Water cooled heat pump for indoors installation WSHN-EE 17-121 RANGE Nominal heating capacity (W10/W45) from 6,68 kw to 38,7 kw Nominal cooling capacity

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

ELFOENERGY LARGE 2 TECHNICAL BULLETIN HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES

ELFOENERGY LARGE 2 TECHNICAL BULLETIN HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES TECHNICAL BULLETIN ELFOENERGY LARGE HIGH EFFICIENCY AIR-COOLED LIQUID CHILLER FOR OUTDOOR INSTALLATION WSAT-XEE SERIES Nominal cooling capacity from to kw ELFOEnergy LARGE is a highly energy efficient

More information

ELFOEnergy Extended Inverter

ELFOEnergy Extended Inverter Technical Bulletin BT14F009GB-03 ELFOEnergy Extended Inverter AIR-COOLED INVERTER CHILLER FOR OUTDOOR INSTALLATION WSAT-XIN 21-171 RANGE PREMIUM Version Nominal cooling capacity (A35/W7) from 4 to 30 kw

More information

ELFOEnergy Duct Inverter

ELFOEnergy Duct Inverter Technical Bulletin BT14E002GB-02(EC1) ELFOEnergy Duct Inverter Air-water ductable liquid chiller for indoor or outdoor installation SERIES WSA-XIN 21-141 Nominal cooling capacity (A35/W7) da 4 a 31 kw

More information

CFI VERTICAL WATER RECESSED DUCTABLE TERMINAL UNIT

CFI VERTICAL WATER RECESSED DUCTABLE TERMINAL UNIT - 71 CFI -71 VERTICAL WATER RECESSED DUCTABLE TERMINAL UNIT CFI - 71 (---) Size Cooling Heating [kw] [kw] 8,7,2 31 12,7 29,3 41,2 33,4 51,7 43,1 71 21,6 5, REPLACE: B27AC-5-95 G4 The CFI series fan-coils

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

ELFOEnergy Extended Inverter

ELFOEnergy Extended Inverter Technical Bulletin BT14F008GB-00 ELFOEnergy Extended Inverter Air cooled inverter heat pump for outdoor installation WSAN-XIN 21-171 RANGE PREMIUM Version Nominal heating capacity (A7/W45) from 5 to 32

More information

ELFOEnergy SHEEN. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XSi RANGE HIGH SEASONAL EFFICIENCY

ELFOEnergy SHEEN. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XSi RANGE HIGH SEASONAL EFFICIENCY Technical Bulletin BT17I022GB-00 ELFOEnergy SHEEN Air source inverter heat pump for outdoor installation WSAN-XSi 10.1 22.2 RANGE Nominal heating capacity (A7/W45) from 23,3 to 61 kw Nominal cooling capacity

More information

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB Packaged air cooled liquid chillers for outdoor installation 42 574 kw technicalcatalogue T_EGL_1012_GB INDEX EUROVENT CERTIFICATION... 3 GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION...

More information

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

ELFOEnergy Magnum - Heat pump

ELFOEnergy Magnum - Heat pump Technical Bulletin BT14E008GB-03 ELFOEnergy Magnum - Heat pump Air-cooled heat pump for outdoor installation WSAN-XIN 18.2-30.2 RANGE Nominal heating capacity (A7/W45) from 56 kw to 93 kw Nominal cooling

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10 Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index

More information

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and

More information

kw COOLING kw HEATING

kw COOLING kw HEATING Heat pump water/water liquid chillers for indoor installation. Inversion on hydraulic circuit. 394 1505 kw COOLING 477 1976 kw HEATING technicalcatalogue T_FRGSCRWP_0913_GB INDEX GENERAL CHARACTERISTICS...

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 01/16 Supersedes: 12/13 Identification code Index Index... pag. 2 Identification code...»

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 04/11 Supersedes: 12/10 Identification code Index Index... pag. 2 Identification code...»

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

VERTICAL WATER RECESSED TERMINAL UNIT

VERTICAL WATER RECESSED TERMINAL UNIT ELFOROOM IN 5-15 VERTICAL WATER RECESSED TERMINAL UNIT ELFOROOM IN (ACQUA) Size Cooling Heating [kw] [kw] 5 1.47 2.85 11 2.81 5.51 15 3.49 6.76 The ELFO terminal unit is fitted with a motor offering a

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

Blue Box Epsilon Echos +

Blue Box Epsilon Echos + Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating

More information

Water chillers water/water type SIGMA Technical information manual

Water chillers water/water type SIGMA Technical information manual Water chillers water/water type SIGMA Technical information manual 2 INDEX Technical features 1 Versions 3 Accessory versions 4 Technical data 7 Electrical data 11 Cooling capacity 12 Heating capacity

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable

More information

Air-to-water scroll chillers

Air-to-water scroll chillers Air-to-water scroll chillers Model CGA 040 to 115 Cooling capacity: 14-40 kw CG-PRC031B-GB Table of Contents Technical specifications...4 Standard configuration... 4 Hydraulic version... 4 Casing... 4

More information

kw. technicalcatalogue

kw. technicalcatalogue Packaged air cooled liquid chillers in A class energy efficiency for outdoor installation equipped with scroll compressor and microchannel condensing coils 108 876 kw technicalcatalogue T_PYXCLA_0413_GB

More information

44,9 202,0 kw. technicalcatalogue

44,9 202,0 kw. technicalcatalogue Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressor and microchannel condensing coils 44,9 202,0 kw technicalcatalogue T_PYXU_0413_GB INDEX EUROVENT CERTIFICATION...

More information

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose

More information

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Air/water cooled chillers and heat pumps 41 303 kw General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Configurations HP: Reversible heat pump LE: For connection to remote evaporator

More information

RTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N

RTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N A RE F S E -FRIEND Y R E IG RA N T G AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L RTA C TECHNICAL MANUAL 1 2 SUMMARY THIS MANUAL IS DIVIDED INTO SECTIONS. THEIR NAMES APPEAR IN THE HEADING

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

ELFOFresh Large. Technical Bulletin. Make-up unit, full fresh air, reversible heat pump. Series CPAN-U 17-51

ELFOFresh Large. Technical Bulletin. Make-up unit, full fresh air, reversible heat pump. Series CPAN-U 17-51 Technical Bulletin BT05L001GB-12 ELFOFresh Large Make-up unit, full fresh air, reversible heat pump Series CPAN-U 17-51 Ideal air exchange rates in shops and offices Cooling,heating and humidification

More information

O L R E RGA ST RA N AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL

O L R E RGA ST RA N AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL -FRIEND A R E IG RA N T G RGA ST RE F S Y E O L C AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL 1 2 SUMMARY THIS MANUAL IS DIVIDED INTO SECTIONS. THEIR NAMES APPEAR IN THE

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata

More information

VERSATEMP EQV-X TECHNICAL BULLETIN DIRECT EXPANSION HIGH EFFICIENCY PACKAGED AIR CONDITIONER EQV-X 3-21 SERIES WATER-AIR HEAT PUMP

VERSATEMP EQV-X TECHNICAL BULLETIN DIRECT EXPANSION HIGH EFFICIENCY PACKAGED AIR CONDITIONER EQV-X 3-21 SERIES WATER-AIR HEAT PUMP TECHNICAL BULLETIN VERSATEMP EQV-X DIRECT EXPANSION HIGH EFFICIENCY PACKAGED AIR CONDITIONER EQV-X 3-21 SERIES WATER-AIR HEAT PUMP Nominal cooling capacity from 1,4 to 4,1 kw Nominal heating capacity from

More information

AQUASNAP JUNIOR 30RHV

AQUASNAP JUNIOR 30RHV High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11

More information

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

ELFOEnergy Ground Medium 2 - Multifunction

ELFOEnergy Ground Medium 2 - Multifunction Technical Bulletin BT15A008GB-06 ELFOEnergy Ground Medium 2 - Multifunction Water cooled heat pump with simultaneous hot / cold water production for indoor installation WSHN-XEE2 MF 10.2-120.2 RANGE Nominal

More information

30RH B Nominal cooling capacity kw Nominal heating capacity kw

30RH B Nominal cooling capacity kw Nominal heating capacity kw Air-to-Water Heat Pumps with Integrated Hydronic Module AQUASNAP Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products.

More information

Conditioning your ambient, maximising your comfort.

Conditioning your ambient, maximising your comfort. High efficiency water cooled chillers, heat pumps and evaporating units with screw compressors and R134a refrigerant gas. Cooling capacity 378 1554 kw Heating capacity 425 1744 kw Cooling capacity evaporating

More information

RLA kw TECHNICAL MANUAL AIR COOLED WATER CHILLERS WITH HELICAL FANS

RLA kw TECHNICAL MANUAL AIR COOLED WATER CHILLERS WITH HELICAL FANS RLA AIR COOLED WATER CHILLERS WITH HELICAL FANS FERROLI adheres to the EUROVENT certification programme. The products concerned appear in the products guide to www.eurovent-certification.com 150.4 165.4

More information

HYDRONIC RESIDENTIAL

HYDRONIC RESIDENTIAL HYDRONIC RESIDENTIAL Chillers, reversible heat pumps and modular units for small and medium applications. Climaveneta. brand of Mitsubishi Electric Hydronics & IT Cooling Systems, presents the mini chiller

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running Climaveneta Technical Bulletin BRH_0011_0121_201211_EN BRH r HFC R-410A 0011-0121 5,5-35,1 kw Water-cooled liquid chillers (The photo of the unit is indicative and may change depending on the model) Versatile

More information

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...

More information

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM TECHNICAL CATALOGUE EQEF Water Chillers with Free Cooling System Models:60.1 60.2 70.1 70.2 90.1 90.2 120.1 120.2 135.1 150.1 190.2 200.1 200.2 240.2 270.2 300.2 Cooling capacities: 69,7 to 331 KW 02.16

More information

KELVIN Clim F497. Kelvin air conditioning

KELVIN Clim F497. Kelvin air conditioning KELVIN Clim F497 Cooling Capacity: 400 ~ 1260 kw Free-Cooling Capacity: 497 ~ 1492 kw Packaged air cooled liquid chillers with free-cooling system in A class energy efficiency for outdoor installation,

More information

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme

More information

PRODUCT GUIDE

PRODUCT GUIDE PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency

More information

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range is an efficient and low-noise product designed for medium to big applications. The water chillers are suitable for water outlet temperatures

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

HYDRONIC System. HYDRONIC System. The complete range of chillers, heat pumps and air handling units in large installations

HYDRONIC System. HYDRONIC System. The complete range of chillers, heat pumps and air handling units in large installations System System The complete range of chillers, heat pumps and air handling units in large installations System is the innovative evolution of the traditional hydronic system. The cooling or thermal energy

More information

Aquaflair TRAC-TRAF-TRAH

Aquaflair TRAC-TRAF-TRAH Aquaflair TRAC-TRAF-TRAH 110 400 kw Air-cooled chillers, free-cooling chillers and heat pumps for mission critical applications Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors

More information

pyxis u pyxis ua NEW rcgroupairconditioning

pyxis u pyxis ua NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44,9 200,0 rcgroupairconditioning R410 C PLTE

More information

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw Air cooled chillers with brushless oil-free compressors R-134a RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw External installation with very low sound level Cooling circuit with

More information

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures

More information

PYXIS U PYXIS U. rcgroupairconditioning

PYXIS U PYXIS U. rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44 284 rcgroupairconditioning MIN FETURES

More information

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Quality Management Systems 30RBY/RQY 017-033 Nominal cooling capacity 15-33 kw Nominal heating capacity 17-31 kw The new

More information

- CONTROL - ESC HOME. 10: Display STEP: 00/00. ON Unit on OFF Unit off 15/02/03 08:03:51 SETUP 10: 12: 13: MODE MODE: no significant

- CONTROL - ESC HOME. 10: Display STEP: 00/00. ON Unit on OFF Unit off 15/02/03 08:03:51 SETUP 10: 12: 13: MODE MODE: no significant - CONTROL - MAIN CONTROL MODULE KEYPAD 1: 2: I Led = alight when unit is ON Led = extinguished when unit is OFF ON/OFF key: when pressed and held for at least 3 seconds, switches the unit on or off 3:

More information

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive,

More information

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line) ERAH MC Ka AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line) Range 394-1220 kw Liquid chillers air condensing unit Package external installation Screw compressors

More information

LZA High efficiency air to water heat pumps with HP compressor

LZA High efficiency air to water heat pumps with HP compressor High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

ELFOEnergy Edge. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XMi RANGE HIGH SEASONAL EFFICIENCY

ELFOEnergy Edge. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XMi RANGE HIGH SEASONAL EFFICIENCY Technical Bulletin BT16N009GB-00 ELFOEnergy Edge Air source inverter heat pump for outdoor installation WSAN-XMi 21 81 RANGE Nominal heating capacity (A7/W45) from 5 to 16 kw Nominal cooling capacity (A35/W7)

More information

pyxis pyxisa NEW rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning

More information

Air Cooled Chillers & Heat Pumps WinPACK HE-A

Air Cooled Chillers & Heat Pumps WinPACK HE-A Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 1 Air Cooled Chillers & Heat Pumps WinPACK HE-A TCAEY-THAEY 2110-4340 Cooling capacity: 91,6-345 kw Heating capacity: 110,5-357 kw Class

More information

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW TECHNICAL CATALOGUE EQSL Air Cooled Water Chillers Models: 300 V2 F06 1310 V2 F16 Cooling capacity: 299 to 1310 KW 02.16 ref. 207598 Rev.100 Thank you for trusting in Hitecsa Products. Our company has

More information

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning Industrial PYXIS CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with scroll compressor and microchannel condensing coils Cooling Capacity: 108 876

More information

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

pyxis hp u pyxis hp u IDEA NEW rcgroupairconditioning Comfort PYXIS HP U : ir / water reversible heat pumps for outdoor installation, equipped with scroll compressors and axial fans Cooling Capacity: 42,3 195,0 Heating Capacity: 47,1 222,0 NEW IDE R410 rcgroupairconditioning

More information

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning : Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 314 1343 Free-Cooling Capacity: 308 938 GLYCOL

More information

CRIMSON & CRIMSON MAX

CRIMSON & CRIMSON MAX High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial

More information

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential

More information

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base

More information

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw

More information

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL RMA ECO-FRIENDLY REFRIGERANT GAS AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the

More information

Kälte Klima. Water cooled water chillers Not Reversible heat pumps from 18 kw to 75 kw. Series:

Kälte Klima. Water cooled water chillers Not Reversible heat pumps from 18 kw to 75 kw. Series: Water cooled water chillers Not eversible heat pumps from 18 kw to 75 kw Series: Issue: MCW N Leaflet: DE 59 03/13 Supersedes: --- Identification code Index MCWY 15/1 N PAC 1 2 3 4 5 6 7 8 1 M mini series

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

www.ecso-klimatechnik.de ECSO GMBH Wetterssteimstr. 53 D- 90471,.. Nurnberg, Deutschland e-mail: info@ecso-klimatechnik.de Tel/Fax: +49 (0) 911/818 9917 TABLE OF SYMBOLS OPERATING MODE OPTIONS VENTILATION

More information

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems Technical Bulletin BT13F002GB-00 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR

More information