1 (B) / (B) Heating Input: 60,000 0,000 BTU/h Modulating, Variable-Speed EM Gas Furnace Up to 98% AFUE ontents Nomenclature... Product Specifications... Dimensions... 4 flow Specifications... 6 Wiring Diagram... Accessories... Standard Features Integrated communicating omfortbridge Technology ommissioning and diagnostics via on board Bluetooth with the oolloud phone and tablet application Heavy-duty stainless-steel tubular heat exchanger Stainless-steel secondary heat exchanger Self-calibrating modulating gas valve auto-configure for each installation Durable Silicon Nitride igniter Quiet variable-speed induced draft blower Self-diagnostic control board with constant memory fault code history output to a dual 7-segment display olor-coded low-voltage terminals with provisions for electronic air cleaner Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand Multiple continuous fan speed options offer quiet air circulation Auto-omfort and enhanced dehumidification modes available All models comply with alifornia 40 ng/j Low x emissions standard For installation in alifornia s South oast Quality Management District (SAQMD) only: This furnace does not meet the SAQMD Rule 4 ng/j x emission limit, and thus is subject to a mitigation fee of up to $40. This furnace is not eligible for the SAQMD lean Furnace Rebate Program: abinet Features Designed for multi-position installation: : upflow, horizontal left or right : downflow, horizontal left or right ertified for direct vent (-pipe) or non-direct vent (-pipe) Easy-to-install top venting with optional side venting onvenient left or right connection for gas and electrical service abinet air leakage (QLeak) % Heavy-gauge steel cabinet with durable finish Fully insulated heat exchanger and blower section tight solid bottom or side return with easy-cut tabs for effortless removal in bottom air-inlet applications * omplete warranty details available from your local dealer or at To receive the Lifetime Heat Exchanger Limited Warranty, the Lifetime Unit Replacement Limited Warranty (in both cases good for as long as you own your home), and the 0-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in alifornia or Québec. SS- /8 Amana is a trademark of Maytag orporation or its related companies and used under license to Goodman ompany, L.P., Houston, Texas. Supersedes 9/8

2 Nomenclature A M V M B N ** 4,6 7,8,9 0,4 Brand A - Amana Brand Engineering Major / Minor Revisions * Not used for inventory control. onfiguration x M - Upflow/Horizontal N - Low x - Downflow/Horizontal abinet Width Motor B - 7½ - " V - Variable Speed EM/omfortBridge D - 4½" E - Multi-Speed EM S - Single Speed Maximum Gas Valve M - Modulating - Two- Stage MBTU/h S - Single Stage ,000 BTU/h ,000 BTU/h AFUE 00-00,000 BTU/h 97-97% AFUE 96-96% AFUE 0-0,000 BTU/h 9-9% AFUE SS-

3 Product Specifications 0804NB 00NB 0DNB 0804NB 00NB Heating Data High Fire Input¹ 60,000 80,000 80,000 00,000 0,000 60,000 80,000 80,000 00,000 High Fire Output¹ 8,800 77,600 78,400 97,000 6,400 8,00 77,600 77,600 97,000 Low-Fire Steady-State Input¹ 0,000 40,000 40,000 0,000 60,000 0,000 40,000 40,000 0,000 Low-Fire Steady-State Output¹ 9,400 8,800 9,00 48,00 8,00 9,00 8,800 8,800 48,00 AFUE² Temperature Rise Range ( F) Vent Diameter³ " - " " - " " - " " - " " - " " - " " - " " - " " - " No. of Burners irculator Blower Available 0." ESP Size (D x W) " x 8" " x 8" " x 0" " x 0" " x " " x 8" " x 8" " x 0" " x 0" 07 RPM ½ ½ ¾ ½ ½ ¾ Speed VS EM VS EM VS EM VS EM VS EM VS EM VS EM VS EM VS EM Electrical Data Min. ircuit Ampacity⁴ Max. Overcurrent Device (amps)⁵ Shipping Weight (lbs) ¹ Natural Gas BTU/h ² DOE AFUE based upon Isolated ombustion System (IS) ³ Installer must supply one or two PV pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either " or " in diameter, depending upon furnace input, number of elbows, length of run and installation ( or pipes). The optional ombustion Pipe is dependent on installation/code requirements and must be " or " diameter PV. ⁴ Minimum ircuit Ampacity = (. x irculator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ⁵ Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HAR-type circuit breakers of the same size as noted. Notes All furnaces are manufactured for use on VA, 60 Hz, single-phase electrical supply. Gas Service onnection ½" FPT Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical ode and/or all existing local codes. For bottom return: Failure to unfold flanges may reduce airflow by up to 8%. This could result in performance and noise issues. For servicing or cleaning, a 4" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. SS-

4 Dimensions 8¾ Intake " Pipe Left-Side Drain Trap Exterior Holes 6½ ¾ ⅝ enter Dimple For Alternate Intake Pipe " OD Hole High-Voltage Standard Gas Supply Location A B ⅞ ¾ ¾ Vent/ Flue Pipe " PV Right-Side Drain Trap Exterior Holes High-Voltage Alternate Gas Supply 6½ 9½ Alternate Vent/ Flue Location ¾ 4½ 4 ½ 9¼ 9⅝ 4⅞ ⅞ 6½ ⅛ 9⅝ 9¼ ⅜ LEFT SIDE VIEW Low-voltage ⅞ ⅜ ½ ondensate Drain Trap Exterior onnection (Right or Left Side) ¾ PV FRONT VIEW D Unfolded Flanges E Folded Flanges ⅞ Low-Voltage ⅞ ⅜ ½ RIGHT SIDE VIEW Unfolded Flanges ½ Folded Flanges Model W D H A B D E Return 7½" 8⅞" 4½" 7½" 6" ⅞" ⅛" ⅝" 7½" 8⅞" 4½" 7½" 6" ⅞" ⅛" ⅝" 0804NB " 8⅞" 4½" " 9½" 7⅞" 6" 7½" 00NB " 8⅞" 4½" " 9½" 7⅞" 6" 7½" 0DNB 4½" 8⅞" 4½" 4½" " 0⅞" 9⅜" 0⅞" Minimum learances to ombustible Materials Position Sides Rear Front Bottom Flue Top Upflow 0" 0" " 0" " Horizontal 6" 0" " 0" 6" = If placed on combustible floor, the floor MUST be wood ONLY. 4 SS-

5 Dimensions ½ 8¼ Vent/Flue Pipe " PV 6½ ½ B Return Intake Pipe PV ⅝ ⅜ Top View ⅝ ⅞ A B ⅝ ½ ⅞ 6½ 8¼ Alternate Vent/ ½ Low-Voltage 4 Low-Voltage Alternate Gas High-Voltage 4½ ⅛ Alternate Gas Supply 4¾ ⅛ 4⅞ 4¾ 4⅛ 6⅞ ⅜ ⅜ 6⅞ Drain Trap Holes Standard Drain Trap 8¾ ½ ½ D Unfolded Flanges E Folded Flanges Front View High-Voltage ⅝ Right Side Exterior Drain Trap Holes 8⅛ Unfolded Flanges 0⅛ Folded Flanges Right-Side View Return Model W D H A B D E 7½" 8⅞" 4½" 7½" 4⅝" 4" 4½" ⅝" 7½" 8⅞" 4½" 7½" 4⅝" 4" 4½" ⅝" 0804NB " 8⅞" 4½" " 8⅛" 7½" 8" 9½" 00NB " 8⅞" 4½" " 8⅛" 7½" 8" 9½" Minimum learances to ombustible Materials Position Sides Rear Front Bottom Flue Top Downflow 0" 0" " N 0" " Horizontal 6" 0" " 0" 6" = If placed on combustible floor, the floor MUST be wood ONLY. N = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring. SS-

6 flow Data MODEL/TEMP RISE RANGE (MID RISE) * -6 (40) * 0-60 (4) 0804NB* - (40) 00NB* -6 (0) 0DNB* -6 (0) RISE RISE RISE RISE RISE Recommended cfm for 00% firing rate & expected temperature rise Lowest recommended cfm for 00% firing rate & expected temperature rise Maximum cfm for 00% firing rate & expected temperature rise TE: Low Heat = High Heat X.7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise ± % 040F040-A * ooling Speed * ooling Speed MAX,400 MAX, NB* ooling Speed 00NB* ooling Speed MAX,760 MAX,00 0DNB* ooling Speed MAX,00 All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 per ton when cooling is desirable. Do not operate above. w.c. ESP in heating mode. Operating between. and.8 w.c. is tabulated for cooling purposes only. Minimum Filter Sizes 0804NB 00NB 0DNB Filter Sizes (in²) (Qty) () 6 x (side or bottom) () 0 x (bottom) or () 6 x (side) Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. 6 SS-

7 flow Data MODEL/TEMP RISE RANGE (MID RISE) * -6 (40) * -6 (0) 0804NB* -6 (0) 00NB* -6 (0) RISE RISE RISE RISE Recommended cfm for 00% firing rate & expected temperature rise Lowest recommended cfm for 00% firing rate & expected temperature rise Maximum cfm for00% firing rate & expected temperature rise TE: Low Heat = High Heat X.7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise ± % 040F040-A * ooling Speed * ooling Speed MAX,400 MAX, NB* ooling Speed 00NB* ooling Speed MAX,760 MAX,00 All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed. For most jobs, about 400 per ton when cooling is desirable. Do not operate above. w.c. ESP in heating mode. Operating between. and.8 w.c. is tabulated for cooling purposes only. Minimum Filter Sizes Filter Sizes (in²) (Qty) () 0 x 0 or () 6 x (top return) 0804NB 00NB () 4 x 0 or () 0 x (top return) Note: Other size filters of equal or greater dimensions may be used. Filters may also be centrally located. SS- 7

8 Temperature Rise Range hart BTU BTU/h OUTT Output vs TEMPERATURE Vs. Temperature RISE Rise hart HART FMULAS BTU BTU/h OUTT Output = = x.08 x x Rise RISE RISE Rise = = Formulas BTU BTU/H OUTT Output.08 x OUTT Output BTU/h BTU/HR x,000 x 000 TEMPERATURE Temperature Rise RISE 8 SS-

9 Wiring Diagram TES: YL HOT SURFAE IGNITER IRUIT ONNET MODULATING GAS VALVE (ITERODGERS) YL LOW FIRE PRESSUR E SWITH AUTO RESET AUXILIARY LIMIT ONTROL 4 8 FS 9 6 EA TWO-STAGE INTEGRATED ONTROL MODULE. SET HEAT ANTIIPAT ON ROOM THERMOSTAT AT 0.7 AMPS.. MANUFATURER'S SPEIFIED REPLAEMENT PARTS MUST BE USED EN SERVIING.. IF ANY OF THE IGINAL WIRE AS SUPPLIED WITH THE FURNAE MUST BE REPLAED, IT MUST BE REPLAED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 0$. USE OPPER ONDUTS ONLY. 4. UNIT MUST BE PERMANENTLY GROUNDED AND ONFM TO N.E.. AND LOAL ODES. 4 4 GR MANUAL RESET ROLLOUT LIMIT ONTROLS (SINGLE ONTROL ON 40 kbtu) AUTO RESET PRIMARY LIMIT ONTROL BURNER OMPARTMENT OWER OMPARTMENT EM MTR HARNESS AUX IN AUX OUT FUSE A 4 RR IRULAT OWER ID OWER TWO-STAGE PRESSURE SWITH ASSEMY HIGH FIRE PRESSURE SWITH FRONT OVER PRESSURE SWITH. TO REALL THE LAST 6 FAULTS, MOST REENT TO LEAST REENT, DEPRESS SWITH F ME THAN SEONDS ILE IN STANDBY ( THERMOSTAT INTS) U V W DATA A EAK OFF TABS 6. HUMIDIFIER INSTALLATION OPTIONS: USE HUM TERMINAL TO RUN HUMIDIFIER DURING HEAT ALL (OMMUNIATING LEGAY MODES). USE HUM-IN AND HUM-OUT TERMINALS TO RUN HUMIDIFIER DURING HEAT ALL ( OMMUNIATING MODE LEGAY MODE) INDEPENDENTLY FROM HEAT ALL (OMMUNIATING MODE ONLY - SETUP IS DONE WITHIN OMMUNIATING THERMOSTAT) TERM BIAS BIAS GN YL TX RX VDD R TX RX TR MV TH LINE R TERM BIAS INDUED DRAFT OWER GN T EAK OFF TABS BIAS YL MOB_PE IGN -N IND -N IND -LO IND -HI IGN LEFT ENTER RIGHT STATUS ODE RAT NA SAT R G W Y DH Y 40 VA INDUT OIL (ON SOME MODELS) YL TRANSFMER FLAME SENS 4 VA VA HASSIS GROUND GN JUNTION BOX OWER OMPARTMENT DO SWITH (OPEN EN DO OPEN) WARNING: DISONNET POWER BEFE SERVIING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. INTEGRATED ONTROL MODULE 4V THERMOSTAT ONNETIONS TO VA/ Ø /60 HZ POWER SUPPLY WITH OVERURRENT PROTETION DEVIE R Y W G TO R FUSE A TO MIRO TO MIRO DO SWITH INDUT OIL (ON SOME MODELS) LINE HUM-OUT LINE HUM EA TO +VD (6) HUM-IN IGN FS TH (4) AUTO RESET AUXILIARY LIMIT ONTROLS HLO (0) PSO (7) PS () PS () () TR () HIGH FIRE PRESS. SWTIH (4) + VD () RX () TX () INTEGRATED ONTROL MODULE OL ODES: LOW VOLTAGE (4V) PINK OWN LOW VOLTAGE FIELD ITE HI VOLTAGE (V) UE GRAY HI VOLTAGE FIELD RED YL YELLOW JUNTION ANGE TERMINAL RPLE INTERNAL TO GN GREEN INTEGRATED ONTROL AK PLUG ONNETION GR DISONNET () () L JUNTION BOX INDO AIR IRULAT WR ELETRONI AIR LEANER TO VA/ Ø /60 HZ POWER SUPPLY WITH OVERURRENT PROTETION DEVIE L N ID WR HOT SURFAE IGNITER FLAME SENS VA 4 VA WARNING:DISONNET POWER BEFE SERVIING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. INDO AIR IRULAT WR N 40 VA TRANSFMER MANUAL RESET ROLLOUT LIMIT ONTROLS FRONT OVER PRESSURE SWITH FIELD FIELD SPLIE DISONNET EQUIPMENT SWITH (TEMP.) IGNITER SWITH (PRESS.) OVERURRENT PROT. DEVIE AUTO RESET PRIMARY LIMIT ONTROL LOW FIRE PRESS. SWITH 4 GAS VALVE INTEGRATED ONTROL MODULE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. 040F048-A SS- 9

10 Accessories Model Description 0804NB 00NB VENT- oncentric Vent Kit (") VENT- oncentric Vent Kit (") RF0004 Drain Kit -Horizontal Left Vertical Flue EFR0 External Filter Rack with 6 x Permanent Filter 070K00000S Flush Mount Vent Kit - " or " 070K0000S Flush Mount Vent Kit - " AFE8-60A Fossil Fuel (Dual Fuel) Kit LPLP0 Low LP Gas Pressure Switch LPM-0 LP onversion Kits HAMFK-0 High Altitude Kit Notes Indicates available for this model For installation in anada, gas furnaces are certified only to 4,00'. 0DNB Model Description 0804NB VENT- oncentric Vent Kit (") VENT- oncentric Vent Kit (") FSB7 Downflow Sub-Base 7." FSB Downflow Sub-Base " K00000S Flush Mount Vent Kit - " or " 070K0000S Flush Mount Vent Kit - " AFE8-60A Fossil Fuel (Dual Fuel) Kit LPLP0 Low LP Gas Pressure Switch LPM-0 LP onversion Kits HAMFK-0 High Altitude Kit Notes Indicates available for this model For installation in anada, gas furnaces are certified only to 4,00'. 00NB Amana is a registered trademark of Maytag orporation or its related companies and used under license to Goodman ompany, L.P. All rights reserved. Our continuing commitment to quality products may mean a change in specifications without notice. 08 Goodman ompany, L.P. Houston, Texas 0 SS-

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h (B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Specifications...5 Wiring

More information

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h (B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Specifications...5 Wiring

More information

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h (B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Data... Wiring Diagrams...

More information

ComfortNet -Compatible

ComfortNet -Compatible GMV8 omfortnet -ompatible Two-Stage, Variable-Speed Gas Furnace 80% AFUE Heating Input: 60,000 00,000 BTU/h Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve

More information

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage

More information

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Heating Input: 40,000 120,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Specifications...7 Wiring Diagram...10

More information

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h Two-Stage onvertible, Multi-Speed EM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h ontents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagrams...

More information

GMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE

GMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE 95%/93% AFUE HEATING INPUT: 46,000 5,000 BTU/H Standard Features / MULTI-POSITION, DUAL$AVER ONVERTIBLE, MULTI-SPEED GAS FURNAE The Goodman / 95%/93% AFUE Dual$aver onvertible, Multi-Speed, Multi-Position

More information

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 96% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Data... Wiring Diagrams... 0

More information

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h ADSH8 Heating Input: 40,000 100,000 BTU/h Two-Stage Convertible Multi-Speed Gas Furnace 80% AFUE Standard Features Two-stage convertible gas valve automatically adjusts to high or low stage Durable SureStart

More information

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagram...

More information

TECHNICAL MANUAL. GMH95 40" 95% Gas Furnace

TECHNICAL MANUAL. GMH95 40 95% Gas Furnace TEHNIAL MANUAL AL 40" 95% Gas Furnace Refer to Service Manual RS660004 for installation, operation, and troubleshooting information. All safety information must be followed as provided in the Service Manual.

More information

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h 80% AFUE Multi-Position, TwinComfort Multi-Speed Gas Furnace Heating Input: 60,000 100,000 BTU/h Standard Features Patented dual-diameter tubular heat exchanger Two-stage gas valve that allows installer

More information

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h Series 80% AFUE Multi-Position, Dual$aver Multi-Speed Gas Furnace Heating Input: 70,000 115,000 BTU/h Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve that allows installer to

More information

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units TEHNIAL MANUAL AL TM ADV8/AMV8 GMV8 80% Gas Furnace Units Refer to Service Manual RS600004 for installation, operation, and troubleshooting information. All safety information must be followed as provided

More information

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units TEHNIAL MANUAL AL TM ADV8/AMV8 GMV8 80% Gas Furnace Units Refer to Service Manual RS660004 for installation, operation, and troubleshooting information. All safety information must be followed as provided

More information

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH GMS95 GAS $AVER 95% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH 95% AFUE s Qualify for a $150 Tax Credit Standard Features Corrosion-resistant, aluminized-steel

More information

GMS9/GCS9 SERIES 93% AFUE

GMS9/GCS9 SERIES 93% AFUE GMS9/GCS9 SERIES 93% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH The GMS9/GCS9 single-stage, multi-speed gas furnaces offer installation versatility.

More information

TECHNICAL MANUAL. ACVC9/AMVC95 GCVC9/GMVC95 90% UP TO 96% Gas Furnace Units

TECHNICAL MANUAL. ACVC9/AMVC95 GCVC9/GMVC95 90% UP TO 96% Gas Furnace Units TEHNIAL MANUAL AL TM AV9/AMV95 GV9/GMV95 90% UP TO 96% Gas Furnace Units Refer to Service Manual RS6612002 for troubleshooting information. Refer to the appropriate Parts atalog for part number information.

More information

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons ANF Series eiling-mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 heck flowrater for heat pump and cooling-only applications All-Aluminum tube/aluminum

More information

AVPTC. Air Handler 1½ to 5 Tons

AVPTC. Air Handler 1½ to 5 Tons Multi-Position, Variable-Speed Air Handler ½ to 5 Tons Standard Features Compatible with the ComfortNet Communicating System family of products Maximum four low-voltage wires required for operation in

More information

GKS9 40" 90% Gas Furnaces

GKS9 40 90% Gas Furnaces TECHNICAL MANUAL AL 40" 90% Gas Furnaces Refer to Service Manual RS6610004* for installation, operation, and troubleshooting information. All safety information must be followed as provided in the Service

More information

AVPTC. Air Handlers 1½ to 5 Tons

AVPTC. Air Handlers 1½ to 5 Tons Multi-Position, Variable-Speed Air Handlers ½ to Tons Standard Features Compatible with the ComfortNet Communicating System family of products R-0A refrigerant-compatible Factory-installed thermal expansion

More information

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. AMS8 33-3/8 Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal TECHNICAL MANUAL AL AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal Refer to Service Manual RS6612006 for troubleshooting information. Refer to the appropriate Parts

More information

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features ASUF Series Multi-Position, Multi-Speed EM-Based Air Handler ½ to Tons ontents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Heat Kit Data... Wiring Diagram...

More information

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... 3 Dimensions...

More information

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h MBV Variable-Speed, omfortnet - ompatible Modular Blowers ooling apacity: 8,000-60,000 BTU/h Standard Features ompatible with the omfortnet ommunication System family of products Variable-speed EM blower

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Variable-speed ECM blower motor ComfortNet Communicating System compatible Auto configuration

More information

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV DVPVC Multi-Position, Variable-Speed Air Handler Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications...3

More information

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004)

H9MPV. 2- Stage Variable Speed 90. Flexibility. Quality. Comfort. Efficiency. Service (7/2004) H9MPV 2- Stage Variable Speed 9 Flexibility Dual Certified venting (1 or 2 pipe). Direct Vent Furnace 4 high with wider cabinets, for noise reduction and ease of installation. Factory shipped as natural

More information

TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. GMS8 33-3/8 Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal TECHNICAL MANUAL AL GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal Refer to Service Manual RS6612006 for troubleshooting information. Refer to the appropriate Parts

More information

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006) T9MPV 2- Stage Variable Speed 9 Flexibility Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 4 high with wider cabinets, for ease of installation. Factory shipped as natural gas, with LP Gas conversion

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat

More information

FG7T (C and L Series)

FG7T (C and L Series) TECHNICAL SPECIFICATIONS FG7T (C and L Series) WARRANTY Smartlite Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The

More information

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible Contents MBVC Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data... Heat Kit Data...

More information

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat Kit Data...6 Wiring Diagram... Accessories... Product Features Internal factory-installed thermal

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGC2T (C and L) Series SmartStart M1200 Product Line Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces 95.1 AFUE Input 60,000-120,000

More information

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33. Gas Furnaces Ruud Achiever Plus Series Two- Stage Multi-position Gas Furnaces - Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature......3 Dimensions...4 Airflow Data...5

More information

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons ASUF Series Multi-Position Multi-Speed ECM Based Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting

More information

TECHNICAL MANUAL. GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. GMS8 33-3/8 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal TECHNICAL MANUAL AL GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal Refer to Service Manual RS6612006for troubleshooting information. All safety information must

More information

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons DVPEC Multi-Position, Variable-Speed air handler Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow

More information

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE TEHNIAL GUIDE Acclimate MODELS: FL9S GAS-FIRED ONDENSING / HIGH EFFIIENY UPFLOW SINGLE STAGE FURNAES 92% AFUE NATURAL GAS 40-135 MBH INPUT EFFIIENY RATING ERTIFIED ISO 9001 ertified Quality Management

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA

More information

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL 25--21--65 Representative photo only, some models may vary in appearance. MANUFACTURED FOR NATURAL GAS CONVERTIBLE TO (LP) PROPANE GAS NOTE: These

More information

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

TECHNICAL MANUAL. GMH8 39 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal TECHNICAL MANUAL AL GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal Refer to Service Manual RS660004 for installation, operation, and troubleshooting information.

More information

Technical Information

Technical Information A I R COMMA ND GAS FURNACE Technical Information 40" 80% Gas Furnaces GUIC EA/EX Refer to Service Manual RS660000 Rev. 2 for installation, operation, and troubleshooting information. All safety information

More information

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS Service Literature orp. 1501-L2 August 2016 Revised March 2017 LRP14HP/DF/A/GE LRP16GE/HP 2 to 5 Ton (7.0 to 17.6 kw) LRP14HP/LRP14DF/LRP14A/LRP14GE/LRP16GE/LRP16HP SERIES UNITS The LRP14/16 series packaged

More information

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7 Multi-Position, Variable-Speed Air Handlers 1½ to 5 Tons Standard Features Suitable for use with R-410A and R-22 refrigerants Check flowrater expansion device for cooling and heat pump applications Variable-speed

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1RA Series M1010 Product Line High Efficiency / Upflow / Horizontal Gas Furnace Induced Draft - 80+ AFUEurnace 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY

More information

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE AUXB00A92A, AUXB060A92A, AUXB060A936A, AUXB080A92A, AUXB080A92A, AUXC080A960A, AUXC00A936A,

More information

T9MPV SmartComfort VS90 Product Specifications

T9MPV SmartComfort VS90 Product Specifications 90+ Variable Speed Two -Stage Heating Furnace FLEXIBILITY Supports two--stage cooling units Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 40 high with wider cabinets, for ease of installation

More information

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. ) FORM NO. GTZ-539 REV. 2 Supersedes Form No. GTZ-503 Rev. 1 SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 96% A.F.U.E. ) TWO STAGE MULTI POSITION GAS FURNACES Features

More information

Wt. Lbs Model Number (BTUH) Hz

Wt. Lbs Model Number (BTUH) Hz Up to 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions F95% AFUE in downflow position California NOx approved Most models have earned the ENERGY STAR

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XR 95 TUHB00A92C, TUHB060A936C, TUHB080A92C, TUHC080A960C, TUHC00A98C, TUHD00A960C, TUHDA960C, TDHB00A92C, TDHB065A92C,

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower 2 10 YEAR WARRANTY WORRY-FREE

More information

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. ) FORM NO. GTZ-540 Supersedes Form No. GTZ-503 Rev. 1 TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] (All Models 95% A.F.U.E. ) TWO STAGE VARIABLE SPEED MULTI POSITION GAS

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U4PSAA Note: Graphics in this document are

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B040U3PSAA Note: Graphics in this document are

More information

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting track for quick repositioning Optimized for

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE FORM NO. GFJ-537 MULTI POSITION GAS FURNACE FF***PS95 Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 95% residential gas furnace CSA certified 4 way multi-poise design

More information

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 1029 L7 SLP98UHV SLP98UHV SERIES UNITS SLP98UHV series units are high efficiency upflow, horizontal right and left) gas furnaces equipped with variable capacity gas valve, variable

More information

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS KG6TE Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 95.1 Upflow/Horizontal The high effi ciency 2-Stage gas furnace

More information

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa) 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Series B approved for Twinning applications (0902116, 1002122, and 1352422) with accessory (order separately) Supports two stage cooling

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in

More information

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. ) FORM NO. G66-536 REV. 5 Supersedes Form No. G66-536 Rev. 3 W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (92% A.F.U.E. ) MULTI POSITION GAS FURNACES Features 92% residential

More information

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D1ACV52A TUD2D140ACV52A TDD2B060ACV32A TDD2B080ACV32A TDD2C100ACV52A

More information

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS FG6T(C,L) Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 92+ Upflow/Horizontal 90+ Downflow The high effi ciency 2-Stage

More information

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG: Submittal Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH Downflow Only S9V2C100D4PSAA Note: Graphics in this document are for representation only. Actual model may differ in appearance. SAFETY

More information

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG: Submittal Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH Upflow, Convertible to Horizontal Right or Horizontal Left S9V2B080U3PSAA Note: Graphics in this document are

More information

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa) 93% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL 93% AFUE, all models all positions F9MES 50 Hz Product Specifications Certified to leak 2% or less of nominal air conditioning CFM delivered when

More information

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. ) FORM NO. GTZ-538 Supersedes Form No. GTZ-503 Rev. 1 TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 95% A.F.U.E. ) 95% A.F.U.E. MULTI POSITION GAS FURNACES Features

More information

TECHNICAL INFORMATION MANUAL

TECHNICAL INFORMATION MANUAL TECHNICAL INFORMATION MANUAL AMS9/ACS9 40" 90% Gas Furnace Model and Manufacturing numbers listed on page 3. Refer to Service Manual RS660000x for installation, operation, and troubleshooting information.

More information

Rheem Classic Series Multi-position Gas Furnaces

Rheem Classic Series Multi-position Gas Furnaces Gas Furnaces Rheem Classic Series Multi-position Gas Furnaces R95P- Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor Contents Nomenclature... 2 Accessories... 2... 3 Dimensions... 4 Airflow Data... 5 Heat Kit Data... 6 Wiring Diagram... 8 Series Product Features Internal factory-installed thermal expansion valves for

More information

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons ACNF Series Ceiling-Mounted Air Handlers 1½ to 2½ Tons Contents Nomenclature...2 Heat Kit Data...2 Product Specifications...3 Dimensions...5 Airflow Data...5 Wiring Diagram...6 Accessories...8 Features

More information

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace Gas Furnaces Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace R802V- Upflow/Horizontal Series 80% A.F.U.E. Input Rates 50-125 kbtu A.F.U.E. (Annual Fuel Utilization

More information

Multi-Position Gas Furnaces

Multi-Position Gas Furnaces MODEL: Multi-Position Gas Furnaces FORM NO. GSC-552 Rev. 1 Sure Comfort 92% A.F.U.E. Multi-Position Gas Furnaces Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] 92% residential gas furnace

More information

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TDC1B040A9241A, TDC1B060A9361A TDC1B080A9421A, TDC1C100A9481A TDC1D120A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1670-10 General

More information

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TUC1B00A921A, TUC1B060A9361A TUC1B080A921A, TUC1C100A981A TUC1D100A9601A, TUC1D1A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1669-15

More information

TSTAT0101SC Recommended (order separately)

TSTAT0101SC Recommended (order separately) Up to 98% AFUE Communicating, Modulating Gas Furnace EASIER TO SELL 98% AFUE on G9MAC0602120, all positions 97% AFUE, all other models, all positions All Models have earned the ENERGY STAR Modulating heating

More information

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces Gas Furnaces Rheem Classic Plus Series Two Stage Multi position Gas Furnaces R96P- Series 96% A.F.U.E. * Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel Utilization Efficiency)

More information

Ruud Achiever Plus Series Multi-position Gas Furnaces

Ruud Achiever Plus Series Multi-position Gas Furnaces Gas Furnaces Ruud Achiever Plus Series Multi-position Gas Furnaces R92T- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE FORM NO. GFJ-552 MULTI POSITION GAS FURNACE 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 92% residential gas furnace CSA certified 4 way multi-poise design 7-Segment LED all

More information

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3 FORM NO. G66-538 REV. 4 Supersedes Form No. G66-536 Rev. 3 W95T- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] MULTI-POSITION GAS FURNACES Features 95% residential gas furnace

More information

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces Gas Furnaces Rheem Prestige Series Communicating Two Stage Variable Speed Multi position Gas Furnaces R96V- Series 96% A.F.U.E. Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel

More information

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80 Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80 TUDA00A92B, TUDA00A930B, TUDA060A92B, TUDA060A936B, TUDB060A936B, TUDB080A92B, TUDB080A936B, TUDB080A98B, TUDC080A960B,

More information

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature Service Literature Corp. 0804 L2 Revised 05 05 2008 G71MPP G71MPP SERIES UNITS G71MPP series units are high efficiency multi position (upflow, downflow, horizontal right and left) gas furnaces equipped

More information

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH FORM NO. G11-508 Supersedes Form No. G11-508 GAS FURNACES RGLE- SERIES ECM Equipped Models with Input Rates from 75,000 to 125,000 BTU/HR 115 Volts, 60 Hz, Single-Phase [22 to 37 kw] (U.S. & Canadian Models)

More information

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES 036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING

More information

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS KG6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency

More information

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace Platinum SV AUD2B060ACV32A AUD2B080ACV32A AUD2C080ACV42A AUD2B100ACV32A AUD2C100ACV52A AUD2D120ACV52A AUD2D140ACV52A Two-Stage Fan Assisted Combustion

More information

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C) TEHNIAL UIDE SINLE PIEE VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLIN & HEAT PUMPS MODELS: AV24 THRU 60*() DESRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa)

TSTAT0101SC Recommended. Cooling Capacity CFM in. w.c. (125 Pa) 96% AFUE, Two Stage, Variable Speed Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER variable speed ECM blower motor Supports two stage cooling units

More information