GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

Size: px
Start display at page:

Download "GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h"

Transcription

1 Two-Stage onvertible, Multi-Speed EM Gas Furnace 80% AFUE Heating Input: 60, ,000 BTU/h ontents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagrams... 6 Accessories... 8 Minimum Filter Sizes... 8 Standard Features Energy-efficient, multi-speed EM blower motor Heavy-duty aluminized steel dualdiameter, tubular heat exchanger Two-stage convertible gas valve automatically adjust to high or low stage Durable Silicon Nitride igniter Quiet single speed draft inducer Self-diagnostic control board with constant memory fault code olor-coded low-voltage terminals with provisions for electronic air cleaner and humidifier Multi-speed blower motor Low continuous fan speed options offer quiet air circulation alifornia Low NOx emissions models available AHRI ertified; ETL Listed abinet Features Multi-position installation: upflow, horizontal left or right with kit abinet air leakage (QLeak) 2% onvenient left or right connection for gas and electrical service Heavy-gauge steel cabinet with durable baked-enamel finish Fully insulated heat exchanger and blower section * omplete warranty details available from your local dealer or at To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in alifornia or Québec. SS- 11/15 Supersedes 9/15

2 Nomenclature G M E B X A A ,6 7,8, Brand Minor Revision G - Goodman Brand A - Initial Release B - First Revision onfiguration - Downflow/Horizontal Major Revision D - Dedicated Downflow A - Initial Release M - Upflow/Horizontal B - First Revision Gas Valve NOx E - Multi- Speed EM N - Natural Gas H - onvertible Two- Stage, Single Phase X - Low NOx S - Single Stage, Single Speed abinet Width AFUE A - 14" - 21" 80-80% AFUE B - 17½" D - 24½" MBTU/h Maximum FM ,000 BTU/h ,000 BTU/h FM ,000 BTU/h ,000 BTU/h FM ,000 BTU/h ,000 BTU/h FM 2 SS-

3 Product Specifications 0603B*B 0805*B 0805D*A 1005*B Performance Data Input¹ 60,000 80,000 80, ,000 Output¹ 48,000 64,000 64,000 80,000 LP Output¹ 48,000 64,000 64,000 80,000 AFUE² Tons 0.5 ESP Temperature Rise Range ( F) irculator Blower Size (D x W) 10 X 8 10 X X X 10 HP 1/ Speed Vent Diameter³ No. of Burners Disposable Filter (in²) Electrical Data Min. ircuit Ampacity⁴ Max. Overcurrent Protection⁵ Ship Weight (lbs) ¹ Low-fire rate is 75% of high-fire rate. ² DOE AFUE based upon Isolated ombustion System (IS). ³ Vent diameter may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas ode NFPA 54/ANSI Z223.1 (in the USA) and the anada National Standard of anada, AN/SA B149.1 and AN/SA B142.2 (in anada). ⁴ Minimum ircuit Ampacity = (1.25 x irculator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical odes. Extensive wire runs will require larger wire sizes. ⁵ Refers to maximum recommended fuse or circuit breaker size; may use fuses or HAR-type circuit breakers of the same size as noted. Notes All furnaces are manufactured for use on 115 VA, 60 Hz, single phase electrical supply. Gas Service onnection ½ FPT Important: It is required to size overcurrent protection device and wires properly and make electrical connections in accordance with the National Electrical ode and/or all existing local codes. SS- 3

4 Dimensions Model A B 0603B** 17½ ** 21 19½ 0805D** 24½ 23" 1005** 21 19½ Minimum learances to ombustible Materials Sides Rear Front Bottom = If placed on combustible floor, the floor MUST be wood ONLY. Notes: For servicing or cleaning, a 24 front clearance is recommended. Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater. Refer to the appropriate USA and anadian codes: In the USA: the National Fuel Gas ode NFPA 54 / ANSI Z223.1 In anada: the anada National Standard of anada, AN/SA B149.1 and AN/SA B142.2 SW Vent B Top 4 SS-

5 Airflow Data Model 0603B*B 0805*B 0805D*A (Med-Hi) 1005*B 0.5 ESP Motor Speed Tons A¹ (FM & Temperature Rise vs. External Static Pressure) External Static Pressure, (Inches Water olumn) FM Rise FM Rise FM Rise FM Rise FM Rise FM FM FM T1 - Yellow T2 - Red 2.0 1, T3 - Orange 2.5 1, , , , , T4 - Blue 3.0 1, , , , , ,129 1,086 1,054 T5 - Black 3.5 1, , , , , ,350 1,305 1,268 T1 - Yellow 2.5 1, , , T2 - Red 3.0 1, , , , , , T3 - Orange 3.5 1, , , , , ,296 1,254 1,197 T4 - Blue 4.0 1, , , , , ,464 1,412 1,368 T5 - Black 5.0 1, , , , , ,679 1,642 1,608 T1 - Yellow 3.5 1, , , , , ,281 1,243 1,190 T2 - Red 4.0 1, , , , , ,488 1,441 1,395 T3 - Orange 4.0 1, , , , , ,692 1,661 1,626 T4 - Blue 4.0 1, , , , , ,768 1,734 1,687 T5 - Black 5.0 2, , , , , ,888 1,844 1,816 T1 - Yellow 3.0 1, , , , , , T2 - Red 3.5 1, , , , , ,193 1,134 1,084 T3 - Orange 4.0 1, , , , , ,320 1,282 1,223 T4 - Blue 4.0 1, , , , , ,482 1,443 1,396 T5 - Black 5.0 1, , , , , ,632 1,605 1,554 Notes FM in chart is without filter(s). Filters do not ship with this furnace, but must be provided by the installer. If the furnace requires two return filters, this chart assumes both filters are installed. All furnaces ship as high-speed cooling and medium-speed heating. Installer must adjust blower cooling and heating speed as needed. For most jobs, about FM per ton when cooling is desirable. INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPEIFIED ON THE RATING PLATE. This chart is for information only. For satisfactory operation, external static pressure should not exceed value shown on the rating plate. At higher altitudes, a properly derated unit will have approximately the same temperature rise at a particular FM, while ESP at the FM will be lower. Factory Motor Speed Setting: T1 = 1st Stage Ht, T2 = 2nd Stage Ht, T5 = ooling Temperature rise data is based on second-stage heat. First-stage heat is 75% of rise indicated above. SS- 5

6 Wiring Diagram WARNING:DISONNET POWER BEFORE SERVIING.WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. XFMR (6) HUMIDIFIER GND INTEGRATED ONTROL MODULE HOT SURFAE IGNITER GR STEADY ON =NORMAL OPERATION OFF 1FLASH = VA HUMIDIFIER LINE NEUTRAL =ONTROL FAILURE 4FLASHES =OPEN HIGH LIMIT G R W Y 7FLASHES =LOW FLAME SIGNAL 24V 115V XFMR PRIMARY LIMIT BR ROLLOUT LIMITS (SINGLE ONTROL ON SOME MODELS) RAPID FLASHES =REVERSED 115 VA POLARITY/VERIFY GND FLAME SENSOR SYSTEM LOKOUT (RETRIES/REYLES EXEEDED) 2FLASHES =PRESSURE SWITH STUK LOSED 3FLASHES =PRESSURE SWITH STUK OPEN FLASHES =FLAME SENSE WITHOUT GAS VALVE 6FLASHES = OPEN ROLLOUT OR OPEN FUSE 2 1 DOOR SWITH SWITH LOATED IN BLOWER OMPARTMENT ON SOME MODELS AUTO 1STG 150 SE XFMR-H LINE-H FUSE SEE NOTE 6 INTEGRATED ONTROL MODULE FS EA-H PM HI STAGE GAS VALVE (HONEY WELL) 5MIN 2STG MODE 100SE 8FLASHES =HEK IGNITER OR IMPROPER GROUND BL OR BR 2NDSTGDLY HTOFFDLY BL BL DIAGNOSTI LED HI HEAT-H OOL-H LO HEAT-H PARK OR BL BR (N) IRULATOR BLOWER AUXILIARY LIMITS BR BL (MED HI) OR(MED) (MED LOW) 15PIN PLUG ON SOME MODELS INDUED DRAFT (HI) BLOWER OMPARTMENT BURNER OMPARTMENT NO BLOWER 24VA HUMIDIFIER PRESSURE SWITH (LOW) 24V THERMOSTAT ONNETIONS INTEGRATED ONTROL MODULE G Y W R TO MIRO XFMR (3) XFMR-H FP LINE-H DOOR SWITH IGN IND LOW VOLTAGE (24V) LOW VOLTAGE FIELD HI VOLTAGE (115V) HI VOLTAGE FIELD JUNTION TERMINAL INTERNAL TO INTEGRATED ONTROL GND (8) MV (9) MVH (12) MVL (2) PS(10) PSO (4) HLI (7) HLO (1) RO2 (11) RO1 (5) AUXILIARY LIMIT ONTROLS 2 HI M1 GAS VALVE MANUAL RESET ROLLOUT LIMIT ONTROL(S) (SINGLE ONTROL ON SOME MODELS) 24 VA OOL-H HI HEAT-H WARNING: DISONNET POWER BEFORE SERVIING. WIRING TO UNIT MUST BE PROPERLY POLARIZED AND GROUNDED. L JUNTION BOX PLUG ONNETION EA-H 115 VA FLAME SENSOR HOT SURFAE IGNITER ID BLWR IRULATOR BLWR JUNTION BOX GND ID BLOWER PRESSURE SWITH NO 40 VA TRANSFORMER IR-N OVERURRENT PROTETION DEVIE LINE-N GND LINE H TO 115 VA/ 1/60HZ POWER SUPPLY WITH OVERURRENT PROTETION DEVIE LO HEAT-H ELETRONI AIR LEANER N IGN-N IND-N EA-N FIELD SPLIE SWITH (TEMP.) SWITH (PRESS.) XFMR-N LINE-N EQUIPMENT GND FIELD GND AUTO RESET PRIMARY LIMIT ONTROL DISONNET IGNITER OVERURRENT PROT. DEVIE INTEGRATED ONTROL MODULE High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. OLOR ODES: YELLOW OR ORANGE RPLE GR GREEN BLAK 0140F00658 REV. A PK PINK BR BROWN ITE BL BLUE GY GRAY RED NOTES: 1. SET HEAT ANTIIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS. 2. MANUFATURER'S SPEIFIED REPLAEMENT PARTS MUST BEUSED EN SERVIING. 3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNAE MUST BE REPLAED, IT MUST BEREPLAED WITH WIRING MATERIAL HAVING ATEMPERATURE RATING OF AT LEAST 105. USE OPPER ONDUTORS ONLY. 4. BLOWER SPEEDS SHOULD BE ADJUSTED BYINSTALLER TO MATH THE INSTALLATION REQUIREMENTS SO AS TO PROVIDE THE ORRET HEATING TEMPERATURE RISE AND THE ORRET OOLING FM. (SEE SPE SHEET FOR AIR FLOW HART) 5. UNIT MUST BE PERMANENTLY GROUNDED AND ONFORM TON.E.. AND LOAL ODES. 6. TO REALL THE LAST 5FAULTS, MOST REENT TOLEAST REENT, DEPRESS SWITH FOR MORE THAN 2SEONDS ILE IN STANDBY(NO THERMOSTAT INTS). 6 SS-

7 Wiring Diagram IRULATOR BLOWER ELETRONI AIR LEANER I NDUER HI HEAT LO HEAT OOL PARK IR NEU EA EA NEU IND K2 K2 K3 K3 K6 K M K4 FATORY JUMPER K5 FATORY JUMPER FP IGN GND MV MLV PS HLO HLI FLAME SENSOR PROBE IGNITOR HI OM PM HIGH LIMIT AUX LIMIT 2-STAGE GAS VALVE PRESSURE SWITH K7 PSO R RO2 RO1 TH XFMR HOT XFMR NEU TR Y G W ROLLOUT SWITH 24 VA OMPRESSOR ONTATOR OIL R Y G W THERMOSTAT Typical Schematic ** Model Furnaces WR 50M Integrated Ignition ontrol SS- 7

8 Accessories Model Description LPM-06 ¹ HANG20 AFE18-60A LP onversion Kit (Springs & Orifice) High-Altitude Natural Gas Kit (4500+ Ft.) Fossil Fuel Kit ¹ Honeywell or White-Rodgers valves Minimum Filter Sizes Model # 0603B** 0805** 0805D** 1005** Filter Size (in²) (1) 16 x 25 (Side) or (1) 14 x 24 (Bottom) (1) 16 x 25 (Side or Bottom) ¹ (2) 16 x 25 (Side) or (1) 20 x 25 (Bottom) Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located. ¹ Use 2-16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity. Goodman Manufacturing ompany, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations Goodman Manufacturing ompany, L.P. Houston, Texas Printed in the USA. 8 SS-

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE Heating Input: 60,000 100,000 BTU/h Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow Data... 5 Wiring Diagram...

More information

ComfortNet -Compatible

ComfortNet -Compatible GMV8 omfortnet -ompatible Two-Stage, Variable-Speed Gas Furnace 80% AFUE Heating Input: 60,000 00,000 BTU/h Standard Features Aluminized steel, dual-diameter tubular heat exchanger Two-stage gas valve

More information

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h ADSH8 Heating Input: 40,000 100,000 BTU/h Two-Stage Convertible Multi-Speed Gas Furnace 80% AFUE Standard Features Two-stage convertible gas valve automatically adjusts to high or low stage Durable SureStart

More information

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h Series 80% AFUE Multi-Position, Dual$aver Multi-Speed Gas Furnace Heating Input: 70,000 115,000 BTU/h Standard Features Dual-diameter tubular heat exchanger Two-stage gas valve that allows installer to

More information

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h (B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Specifications...5 Wiring

More information

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h (B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Specifications...5 Wiring

More information

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h (B) Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 9% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Data... Wiring Diagrams...

More information

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace Heating Input: 40,000 120,000 BTU/h / Single-Stage Multi-Speed Gas Furnace up to 96% AFUE Standard Features Heavy-duty aluminized-steel tubular heat exchanger Stainless-steel secondary heat exchanger Single-stage

More information

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h / Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Heating Input: 40,000 120,000 BTU/h Contents Nomenclature...2 Product Specifications...3 Dimensions...5 Airflow Specifications...7 Wiring Diagram...10

More information

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

GMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE

GMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE 95%/93% AFUE HEATING INPUT: 46,000 5,000 BTU/H Standard Features / MULTI-POSITION, DUAL$AVER ONVERTIBLE, MULTI-SPEED GAS FURNAE The Goodman / 95%/93% AFUE Dual$aver onvertible, Multi-Speed, Multi-Position

More information

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h / Heating Input: 40,000 120,000 BTU/h Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE Contents Nomenclature...2 Product Specifications...3 Dimensions...5 flow Specifications...7 Wiring Diagram...10

More information

AMVM97 (B) / ACVM97 (B)

AMVM97 (B) / ACVM97 (B) (B) / (B) Heating Input: 60,000 0,000 BTU/h Modulating, Variable-Speed EM Gas Furnace Up to 98% AFUE ontents Nomenclature... Product Specifications... Dimensions... 4 flow Specifications... 6 Wiring Diagram...

More information

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h 80% AFUE Multi-Position, TwinComfort Multi-Speed Gas Furnace Heating Input: 60,000 100,000 BTU/h Standard Features Patented dual-diameter tubular heat exchanger Two-stage gas valve that allows installer

More information

TECHNICAL MANUAL. GMH95 40" 95% Gas Furnace

TECHNICAL MANUAL. GMH95 40 95% Gas Furnace TEHNIAL MANUAL AL 40" 95% Gas Furnace Refer to Service Manual RS660004 for installation, operation, and troubleshooting information. All safety information must be followed as provided in the Service Manual.

More information

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. AMS8 33-3/8 Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal TECHNICAL MANUAL AL AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal Refer to Service Manual RS6612006 for troubleshooting information. Refer to the appropriate Parts

More information

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons ANF Series eiling-mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 heck flowrater for heat pump and cooling-only applications All-Aluminum tube/aluminum

More information

TECHNICAL MANUAL. GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. GMS8 33-3/8 Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal TECHNICAL MANUAL AL GMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal Refer to Service Manual RS6612006 for troubleshooting information. Refer to the appropriate Parts

More information

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units TEHNIAL MANUAL AL TM ADV8/AMV8 GMV8 80% Gas Furnace Units Refer to Service Manual RS600004 for installation, operation, and troubleshooting information. All safety information must be followed as provided

More information

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units

TECHNICAL MANUAL. ADVC8/AMVC8 GMVC8 80% Gas Furnace Units TEHNIAL MANUAL AL TM ADV8/AMV8 GMV8 80% Gas Furnace Units Refer to Service Manual RS660004 for installation, operation, and troubleshooting information. All safety information must be followed as provided

More information

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

TECHNICAL MANUAL. GMH8 39 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal TECHNICAL MANUAL AL GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal Refer to Service Manual RS660004 for installation, operation, and troubleshooting information.

More information

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h Heating Input: 0,000 0,000 BTU/h Two-Stage, Variable-Speed EM Gas Furnace Up to 96% AFUE ontents Nomenclature... Accessories... Product Specifications... Dimensions... flow Data... Wiring Diagrams... 0

More information

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH GMS95 GAS $AVER 95% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH 95% AFUE s Qualify for a $150 Tax Credit Standard Features Corrosion-resistant, aluminized-steel

More information

GMS9/GCS9 SERIES 93% AFUE

GMS9/GCS9 SERIES 93% AFUE GMS9/GCS9 SERIES 93% AFUE Multi-Position, Single-Stage/Multi-Speed Gas Furnace Heating Capacity: 46,000 115,000 BTUH The GMS9/GCS9 single-stage, multi-speed gas furnaces offer installation versatility.

More information

TECHNICAL MANUAL. GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

TECHNICAL MANUAL. GMS8 33-3/8 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal TECHNICAL MANUAL AL GMS8 33-3/8" 80% Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal Refer to Service Manual RS6612006for troubleshooting information. All safety information must

More information

TECHNICAL MANUAL. ACVC9/AMVC95 GCVC9/GMVC95 90% UP TO 96% Gas Furnace Units

TECHNICAL MANUAL. ACVC9/AMVC95 GCVC9/GMVC95 90% UP TO 96% Gas Furnace Units TEHNIAL MANUAL AL TM AV9/AMV95 GV9/GMV95 90% UP TO 96% Gas Furnace Units Refer to Service Manual RS6612002 for troubleshooting information. Refer to the appropriate Parts atalog for part number information.

More information

GKS9 40" 90% Gas Furnaces

GKS9 40 90% Gas Furnaces TECHNICAL MANUAL AL 40" 90% Gas Furnaces Refer to Service Manual RS6610004* for installation, operation, and troubleshooting information. All safety information must be followed as provided in the Service

More information

Technical Information

Technical Information A I R COMMA ND GAS FURNACE Technical Information 40" 80% Gas Furnaces GUIC EA/EX Refer to Service Manual RS660000 Rev. 2 for installation, operation, and troubleshooting information. All safety information

More information

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features ASUF Series Multi-Position, Multi-Speed EM-Based Air Handler ½ to Tons ontents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... Heat Kit Data... Wiring Diagram...

More information

GME8 33-3/8" 80% Gas Furnace Upflow/Horizontal

GME8 33-3/8 80% Gas Furnace Upflow/Horizontal TECHNICAL MANUAL AL GME8 33-3/8" 80% Gas Furnace Upflow/Horizontal Refer to current Service Manual RS6610004 for installation, operation, and troubleshooting information. All safety information must be

More information

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h MBV Variable-Speed, omfortnet - ompatible Modular Blowers ooling apacity: 8,000-60,000 BTU/h Standard Features ompatible with the omfortnet ommunication System family of products Variable-speed EM blower

More information

TECHNICAL INFORMATION MANUAL

TECHNICAL INFORMATION MANUAL TECHNICAL INFORMATION MANUAL GDS8, GMS8, GHS8 40" 80% Gas Furnace Units Models listed on page 3 Refer to Service Manual RS6610004 for installation, operation, and troubleshooting information. All safety

More information

AVPTC. Air Handlers 1½ to 5 Tons

AVPTC. Air Handlers 1½ to 5 Tons Multi-Position, Variable-Speed Air Handlers ½ to Tons Standard Features Compatible with the ComfortNet Communicating System family of products R-0A refrigerant-compatible Factory-installed thermal expansion

More information

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV DVPVC Multi-Position, Variable-Speed Air Handler Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications...3

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature...... Dimensions...4 Airflow Data...5 Heat

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature......3 Dimensions...4 Airflow Data...5

More information

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE TEHNIAL GUIDE Acclimate MODELS: FL9S GAS-FIRED ONDENSING / HIGH EFFIIENY UPFLOW SINGLE STAGE FURNAES 92% AFUE NATURAL GAS 40-135 MBH INPUT EFFIIENY RATING ERTIFIED ISO 9001 ertified Quality Management

More information

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Variable-speed ECM blower motor ComfortNet Communicating System compatible Auto configuration

More information

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible Contents MBVC Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data... Heat Kit Data...

More information

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D1ACV52A TUD2D140ACV52A TDD2B060ACV32A TDD2B080ACV32A TDD2C100ACV52A

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XL 95 TUH2B060A936VA, TUH2B080A92VA, TUH2C100A98VA, TUH2D1A960VA, TDH2B060A936VA, TDH2B080A92VA, TDH2C100A98VA, TDH2D1A960VA

More information

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7 Multi-Position, Variable-Speed Air Handlers 1½ to 5 Tons Standard Features Suitable for use with R-410A and R-22 refrigerants Check flowrater expansion device for cooling and heat pump applications Variable-speed

More information

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS Service Literature orp. 1501-L2 August 2016 Revised March 2017 LRP14HP/DF/A/GE LRP16GE/HP 2 to 5 Ton (7.0 to 17.6 kw) LRP14HP/LRP14DF/LRP14A/LRP14GE/LRP16GE/LRP16HP SERIES UNITS The LRP14/16 series packaged

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1RA Series M1010 Product Line High Efficiency / Upflow / Horizontal Gas Furnace Induced Draft - 80+ AFUEurnace 2 10 YEAR WARRANTY WORRY-FREE PERFORMANCE 5 YEAR DEPENDABILITY

More information

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV Upflow/Horizontal 2-Stage, Communicating Speed Gas Furnace Platinum SV AUD2B060ACV32A AUD2B080ACV32A AUD2C080ACV42A AUD2B100ACV32A AUD2C100ACV52A AUD2D120ACV52A AUD2D140ACV52A Two-Stage Fan Assisted Combustion

More information

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons DVPEC Multi-Position, Variable-Speed air handler Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow

More information

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features M Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow Data... 5 Heat

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TM TECHNICAL SPECIFICATIONS Model PGF1TE 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 95.1 AFUE Direct Vent or Non Direct Vent Condensing Furnace 10 YEAR WARRANTY WORRY-FREE PERFORMANCE

More information

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION

50M56U-843 INSTALLER MUST READ DESCRIPTION PRECAUTIONS WARNING CAUTION 50M56U-843 Universal Single Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS INSTALLER MUST READ PAGE 3 CONTAINS WIRING HARNESS AND BLOWER CONNECTION INSTRUCTIONS FOR ALL APPLICATIONS

More information

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... 3 Dimensions...

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 50V64-743 Integrated Furnace Control for Furnaces with Variable Fan Speed INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY

More information

FG7T (C and L Series)

FG7T (C and L Series) TECHNICAL SPECIFICATIONS FG7T (C and L Series) WARRANTY Smartlite Two Stage, Variable Speed, Condensing Upflow/Horizontal and Downflow Gas Furnaces Induced Draft - 95.1 AFUE Input 60,000-120,000 Btuh The

More information

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features MBVC Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data...

More information

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 Check flowrater for heat pump and cooling-only applications All-aluminun tube/aluminum

More information

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa) 80% Variable Speed, Two Stage Heating Furnace EASIER TO SELL 80% AFUE Series B approved for Twinning applications (0902116, 1002122, and 1352422) with accessory (order separately) Supports two stage cooling

More information

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. )

TZ96MDP SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 96% A.F.U.E. ) FORM NO. GTZ-539 REV. 2 Supersedes Form No. GTZ-503 Rev. 1 SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 96% A.F.U.E. ) TWO STAGE MULTI POSITION GAS FURNACES Features

More information

AVPTC. Air Handler 1½ to 5 Tons

AVPTC. Air Handler 1½ to 5 Tons Multi-Position, Variable-Speed Air Handler ½ to 5 Tons Standard Features Compatible with the ComfortNet Communicating System family of products Maximum four low-voltage wires required for operation in

More information

RG7D 1-Stage Heat Series

RG7D 1-Stage Heat Series TECHNICAL SPECIFICATIONS RG7D 1-Stage Heat Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace

More information

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL 25--21--65 Representative photo only, some models may vary in appearance. MANUFACTURED FOR NATURAL GAS CONVERTIBLE TO (LP) PROPANE GAS NOTE: These

More information

MBR. Multi-Position. Modular Blower

MBR. Multi-Position. Modular Blower M Product Features Direct drive, multi-speed PSC blower motor kw 1 kw electric heat kits Blower section usable as electric heater Horizontal or vertical configuration capabilities 1" depth for easier attic

More information

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS 50M56-743 Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD

More information

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price

Product Data. 58RAV High-Efficiency Downflow/Horizontal Induced-Combustion Gas Furnace. 80% AFUE At Budget Price Product Data 58RAV High-Efficiency Downflow/Horizontal Induced-ombustion Gas Furnace Input apacities: 50,000 thru 5,000 Btuh 80% AFUE At Budget Price DOWNFLOW HORIZONTAL arrier provides an 80% Annual Fuel

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGF1TA 2 Stage Series Upflow/Horizontal M1010 Product Line High Efficiency / 80+ Upflow/Horizontal 2 Stage Gas Furnace with Variable Speed Blower 2 10 YEAR WARRANTY WORRY-FREE

More information

MERIT SERIES Downflow

MERIT SERIES Downflow PRODUCT SPECIFICATIONS GAS FURNACES ML80DF MERIT SERIES Downflow Bulletin No. 20643 February 208 Supersedes November 207 AFUE - 80% Input - 44,000 to 0,000 Btuh Nominal Add-on Cooling -.5 to 5 Tons MODEL

More information

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS FG6T(C,L) Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 92+ Upflow/Horizontal 90+ Downflow The high effi ciency 2-Stage

More information

TECHNICAL INFORMATION MANUAL

TECHNICAL INFORMATION MANUAL TECHNICAL INFORMATION MANUAL AMS9/ACS9 40" 90% Gas Furnace Model and Manufacturing numbers listed on page 3. Refer to Service Manual RS660000x for installation, operation, and troubleshooting information.

More information

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33. Gas Furnaces Ruud Achiever Plus Series Two- Stage Multi-position Gas Furnaces - Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS KG6TE Series High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas with Variable Speed Blower 95.1 Upflow/Horizontal The high effi ciency 2-Stage gas furnace

More information

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor Contents Nomenclature... 2 Accessories... 2... 3 Dimensions... 4 Airflow Data... 5 Heat Kit Data... 6 Wiring Diagram... 8 Series Product Features Internal factory-installed thermal expansion valves for

More information

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS TECHNICAL SPECIFICATIONS KG6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency

More information

50A Integrated Furnace Control

50A Integrated Furnace Control 50A56-956 Integrated Furnace Control INSTALLATION INSTRUCTIONS FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY

More information

Technical Manual MAY 2008 Edition

Technical Manual MAY 2008 Edition SPECIFICATION - GMP SERIES MULTI POSITION INDUCED DRAFT GAS FURNACE EARLY MODELS WITH HOT SURFACE IGNITION AND LATER MODELS WITH DIRECT SPARK IGNITION A.G.A. Approval No. 5113 Technical Manual MAY 2008

More information

40 Residential Gas Furnace Operation

40 Residential Gas Furnace Operation 40 Residential Gas Furnace Operation Model Evolution/Nomenclature Heating Sequence of Operation Schematics Ignition Systems Service/Troubleshooting American Standard Inc. 999 Preface Air Conditioning and

More information

Wt. Lbs Model Number (BTUH) Hz

Wt. Lbs Model Number (BTUH) Hz Up to 96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL Up to 96% AFUE in upflow and horizontal positions F95% AFUE in downflow position California NOx approved Most models have earned the ENERGY STAR

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 21M51U-843 Universal Integrated Two-Stage 120Volt Hot Surface Ignition Control Kit INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS

More information

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. )

TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to kw] (All Models 95% A.F.U.E. ) FORM NO. GTZ-540 Supersedes Form No. GTZ-503 Rev. 1 TZ96MDV SERIES Model with Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] (All Models 95% A.F.U.E. ) TWO STAGE VARIABLE SPEED MULTI POSITION GAS

More information

50A Integrated Furnace Control

50A Integrated Furnace Control Goodman White-Rodgers 0130F00005 PCBBF110 PCBBF123 50A55-743 0130F00005S PCBBF110S PCBBF123S 50A55-289 B1809926 PCBBF112 50T55-289 B1809926S PCBBF112S 50A55-743 Integrated Furnace Control INSTALLATION

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 50A65-843 Universal Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING

More information

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace XR 95 TUHB00A92C, TUHB060A936C, TUHB080A92C, TUHC080A960C, TUHC00A98C, TUHD00A960C, TUHDA960C, TDHB00A92C, TDHB065A92C,

More information

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING DIRECT OR NON -DIRECT VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal FLEXIBILITY S Dual certified venting (1 or 2 pipes) Direct Vent furnace S

More information

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE AUXB00A92A, AUXB060A92A, AUXB060A936A, AUXB080A92A, AUXB080A92A, AUXC080A960A, AUXC00A936A,

More information

Ruud Achiever Plus Series Multi-position Gas Furnaces

Ruud Achiever Plus Series Multi-position Gas Furnaces Gas Furnaces Ruud Achiever Plus Series Multi-position Gas Furnaces R92T- Series 92% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated

More information

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. )

W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to kw] (92% A.F.U.E. ) FORM NO. G66-536 REV. 5 Supersedes Form No. G66-536 Rev. 3 W92P- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (92% A.F.U.E. ) MULTI POSITION GAS FURNACES Features 92% residential

More information

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. ) FORM NO. GTZ-538 Supersedes Form No. GTZ-503 Rev. 1 TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] (All Models 95% A.F.U.E. ) 95% A.F.U.E. MULTI POSITION GAS FURNACES Features

More information

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3 FORM NO. G66-538 REV. 4 Supersedes Form No. G66-536 Rev. 3 W95T- SERIES Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] MULTI-POSITION GAS FURNACES Features 95% residential gas furnace

More information

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006)

T9MPV. 2- Stage Variable Speed 90. Flexibility. Comfort. Efficiency. Quality. Service (05/2006) T9MPV 2- Stage Variable Speed 9 Flexibility Dual Certified venting (1 or 2 pipe), Direct Vent Furnace 4 high with wider cabinets, for ease of installation. Factory shipped as natural gas, with LP Gas conversion

More information

MULTI POSITION GAS FURNACE

MULTI POSITION GAS FURNACE FORM NO. GFJ-537 MULTI POSITION GAS FURNACE FF***PS95 Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] Features 95% residential gas furnace CSA certified 4 way multi-poise design

More information

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons Product Features Check flowrator for cooling and heat pump applications Direct drive, multi-speed ECM blower motor All-aluminum evaporator coil Coil mounting track for quick repositioning Optimized for

More information

G6RC Series TECHNICAL SPECIFICATIONS

G6RC Series TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS G6RC Series High Efficiency / Direct Vent or Non Direct Vent Condensing Upflow/ Horizontal Gas Furnace Induced Draft - 92+ AFUE Input 40,000-120,000 Btuh The high effi ciency upfl

More information

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES 036-1354-001 Rev. D (110) Heating TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE NATURAL GAS 37-111 MBH OUTPUT Air Conditioning EFFICIENCY RATING

More information

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 95%+ AFUE Input 45,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially

More information

Rheem Classic Series Multi-position Gas Furnaces

Rheem Classic Series Multi-position Gas Furnaces Gas Furnaces Rheem Classic Series Multi-position Gas Furnaces R95P- Series 95% A.F.U.E. Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! WHITE-RODGERS 50A55-286 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

Multi-Position Gas Furnaces

Multi-Position Gas Furnaces MODEL: Multi-Position Gas Furnaces FORM NO. GSC-552 Rev. 1 Sure Comfort 92% A.F.U.E. Multi-Position Gas Furnaces Models with Input Rates from 40 to 115 kbtu [11.72 to 33.71 kw] 92% residential gas furnace

More information

Operator: Save these instructions for future use!

Operator: Save these instructions for future use! 031-01284-000/50A55-241 Integrated Furnace Control INSTALLATION INSTRUCTIONS Operator: Save these instructions for future use! FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 TUC1B00A921A, TUC1B060A9361A TUC1B080A921A, TUC1C100A981A TUC1D100A9601A, TUC1D1A9601A Single-Stage Fan Assisted Combustion System PUB. NO. 22-1669-15

More information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Model PGC2T (C and L) Series SmartStart M1200 Product Line Two Stage, Variable Speed, High Efficiency Upflow/Horizontal and Downflow Gas Furnaces 95.1 AFUE Input 60,000-120,000

More information

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces Gas Furnaces Rheem Classic Plus Series Two Stage Multi position Gas Furnaces R96P- Series 96% A.F.U.E. * Input Rates from 60 to 100 kbtu [17.58 to 29.31 kw] A.F.U.E. (Annual Fuel Utilization Efficiency)

More information