ORTEC U L INDUSTRIAL WATER SAVER & PUMPING STATIONS. Compressed Air, Gas & Fluid Technologies. 3-way Thermostatic Valve. State-of-the-art Controller
|
|
- Angelina Lester
- 5 years ago
- Views:
Transcription
1 OR ompressed ir, as & luid echnologies nvironment riendly NUSR WR SVR & UMN SONS igh fficiency rim ooler 3way hermostatic Valve U Stateoftheart ontroller hoice of NM nclosures entrifugal umps R
2 Why Water Saver? he new Water Saver from Nortec is your most efficient combatant against the rising energy costs. his closedloop cooling system is self contained and is designed to remove heat from water cooled machinery. t can very efficiently cool the fluid to temperatures slightly above the ambient. Operating rinciple dvantages Quick and easy installation and commissioning esigned and manufactured to suit your application losedloop system eliminates the possibility of corrosion and contamination Requires little or no maintenance onsistent temperatures enhances process efficiency Saves $$ no more city water/sewer recurring costs ypical process cooling fluid (water with varying proportions of glycol) is circulated through the closed loop system by using pumps. mbient air is sucked from the bottom of the Water Saver. his results in a steady flow of air around the tubes carrying the cooling fluid. With the use of thermally activated valve (optional) and an additional trimcooler, temperatures very close to ambient and below can be achieved. ool Water Out ot Water n qua ool ypass (Optional) irooled Water Saver ity Water nlet Optional rim ooler and ontrols ity Water Outlet xpansion ank ump djustable igh ressure ypass Valve ypical Water Saver with Optional umping station and rim cooler Standard eatures: Vertical/orizontal ir ischarge onfiguration alvanized Steel rame and asing urable luminum asing luminum ins Mechanically xpanded into opper ubes 6 pole, 30/4V, Single/hree hase, O an Motors ully affled an Sections NM 3R Suitable for Outdoor nstallation an Motor Starter an Motor using lose oupled entrifugal ump (Optional) repiped, actory ssembled and ested ll Nortec Water Saver are designed for vertical airflow. (orizontal airflow is available as an option). ll units are U & U and M listed. ll units are constructed of heavygauge, corrosion resistant galvanized steel for maximum casing rigidity. Multiple fan units are separated by full width baffles to prevent air bypass. his provides additional casing reinforcement. o enhance the tube life, all end panels, center supports and partitions have collared tube holes. he fluid coils are constructed using seamless copper tubing on a staggered pattern. ubes are mechanically expanded into continuous full collared platetype aluminum (or optional copper) fins for permanent metaltometal contact. eaders come equipped with vents and drains. ll coils are factory pressure and leak tested at 0 S. he aluminum fans with painted steel hubs are dynamically balanced and factory tested before shipping to ensure quiet operation. an guards are designed from heavygauge, closemeshed steel wire with vinyl coating for maximum rigidity, long life and attractive appearance. an motors are heavy duty S or three phase open dripproof type with permanently lubricated ball bearings and builtin overload protection. ll motors are factory wired with leads terminating in a weather tight enclosure located opposite the header end of the unit.
3 Optional eatures: Specially oated ins (opper, olyester, henoliccoated oils) an Motors asy ccess oil leaning anels an ycling ontrol System NM 4 ontrols orrosion Resistant eavy auge mbossed luminum. Special opper oils ypass luid ontrol Valves emperature ontrolled an Speed Water Saver Specifications MO NO: MNMUM RORMN M M 0 MXMUM RORMN M M 0 VO 30/4/3/ N NO: O NS R (M) N OU (M) W (S) OMRSSOR W R OOR () 100WSS 00WSS 300WSS 0WSS 0WS 500WSS 0WSS 0WS 800WS 1000WS 100WS /6 1/15 3/15 7/15 8/16 35/18 41/1 41/8 /8 67/34 80/ ½ ½ bove performance is based on mbient emperature 1 0 ntering luid emperature % thylene lycol concentration M = U / 1000 erformance range is provided to suggest approximate capacity. or final selections, contact Nortec. ntering fluid temperature 0 eaving fluid temperature 0 luid low rate M luid oncentration (Water/lycol) % mbient temperature 0 Option for dditional Modules Water ooled ompressor ate Valve K low Meter emperature ontrol fter ooler ity Water nlet ity Water Outlet Optional rim ooler K Over ressure ontrol ump xpansion ank M M Water Saver emperature auge ressure auge
4 ow to size the Water Saver apacity = eat oad lycol orrection actor lycol oncentration % actor xample: Which Water Saver is suitable for the following conditions? ompressor = 00 U/ = 0 Motor Service actor = 1.15 lycol content = 30% apacity = = = apacity in M = ompressor x U/ x Motor Service actor lycol orrection actor 00x 0 x U apacity in M = U 1000 Referring to the specification table, Model No. 500WSS is selected. umping Station Specifications umping Station Nortec provides the choice of either a Single (SS Series) or a ouble (S series) pumping station. he typical pumping station package includes the pump, the starter, your choice of NM enclosure along with monitoring lights and ON/O switch. he entire unit is prepiped and mounted on a skid. he S series comes with pumps and separate control valves. hese units come with standard of 30/4 voltage. Optional voltages are also available upon request. utodual controller he universal pump controller incorporates the latest in electronic technology in a compact and userfriendly enclosure. he controller is independent of the pump size. he failsize design ensures that the pumping station will operate at the maximum level of efficiency. With its monitoring capability, it enables equal running time of the pumps. his makes it convenient to schedule maintenance activities. MO# 75SS/S UM SS S 0.75 () 0.75 M@. 30@ N/ OU 1 N VO 110/081 MNSONS N NS SMX SS UX S 36x30x48 48x3x48 W (S) 100SS/S 1 () 1 46@ 1 N /43 36x30x48 48x3x SS/S () 55@ 1 N 30/43 36x30x48 48x3x SS/S () 75@70 N 30/43 36x30x48 48x3x SS/S 3 () 3 80@70 N 30/43 X3X48 X36X SS/S 5 () 5 10@90 N 30/43 X3X48 X36X SS/S 7.5 () @100 1/ N 30/43 48X36X48 X48X SS/S 10 () 10 30@100 1/ N 30/43 48X36X48 X48X SS/S 15 () 15 80@ /43 XX 70XX SS/S 0 () 0 30@ /43 XX 70XX SS/S 5 () 5 40@ /43 XX 70XX SS/S 30 () @ /43 70X48X80 80X70X SS/S () 0@ /43 70X48X80 80X70X SS/S 50 () @ /43 80XX90 90X80X * SS umping Station Single * S umping Station ouble
5 umping Station Single (SS) umping Station ouble (S) NM lectrical nclosure Nortec closed coupled and base mounted centrifugal pumps provide economical performance for a wide range of applications of varying flow rate and head pressure. (low rates up to 500 M and head pressure up to 1 feet). he double pump setup is mounted on a heavy skid with a separate regulating valve for each pump. he pump setup come with an isolation valve and maintenance activities can be carried out without shutting down the system. Nortec umping stations are equipped with your choice of NM enclosures. Optional control and monitoring indicators can be added along with state of the art controllers. ontroller igh fficiency rim ooler 3 way hermostatic Valve Optional state of the art controllers are used for optimizing the performance of the pumping stations. he s (rogrammable ogic ontrollers) are designed with easeofuse in mind. heir modular and versatile features make it suitable for your applications including local and remote display. Optional connections are also available. he trim coolers are mounted inline with counter flow and are typically shell and tube or plate type. t monitors the outlet temperature and with its optional autoregulating feature and ensures consistent inlet temperature to the heat source. dditionally it has bleed and drain valves for maintenance purposes. hese modulating thermal valves are designed to bypass around coolers during startup and then provide accurate temperature control for cooling systems during normal operation. hey do not require any outside control to operate.
6 Water Saver imensional ata 100WSS 00WSS 300WSS 0WSS 500WSS 0WSS SN N W W N OU / / /4 411/4 411/4 411/4 411/4 411/4 ½ ½ OU N W W N OU 0WS / 861/ 0WS 800WS 1000WS 100WS / 901/ 901/ 901/ / 861/ 861/ 861/ ½ ½ lectrical ox lectrical ox R R W W lectrical ox lectrical ox 64 lectrical ox lectrical ox 64 NOR ORORON ompressed ir, as & luid echnologies 1713 enry. ane, Maryville N el: ax: Water Saver and umping Stations igh apacity ryers luid hillers Refrigerated ryers esiccant ryers eatless & eated Specifications subject to change without notice 11/09
TABLE OF CONTENTS. FCV Nomenclature 3. FCV Features & Construction 4. FCV Engineering Specifications 5. FCV Fan/Coil Data 6
TABLE OF CONTENTS Page FCV Nomenclature 3 FCV Features & Construction 4 FCV Engineering Specifications 5 FCV Fan/Coil Data 6 FCV Unit Weights and Volumes 7 FCV Fan and Motor Data 8-9 Dimensions 10-14 Standard
More informationRefrigerated Air Dryer
T.S30-8 Refrigerated ir ryer Series IF/IU ir flow capacity Power consumption Refrigerant Increased up to the max. 40% ecreased up to the max. 40% F34a oefficient of destruction for ozone is zero. Improved
More informationUtility and Centrifugal
Utility and entrifugal Utility and entrifugal reenheck s tiered centrifugal product offering reenheck s tiered model approach gives you flexibility in size, performance and construction, matching the appropriate
More informationIDU22C, 22C1, 37C, 37C1, 55C, 75C
Refrigerated ir ryer Series IU edium IU, 1, 7, 71, 55, 75 () () () () () Run light Operation (ftercooler) Stop (ftercooler) Outlet air pressure gauge vaporation () (I) () Terminal block () () P rain port
More informationRefrigerated Air Dryers
Refrigerated ir ryers Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment
More informationRefrigerated Air Dryers
Refrigerated ir ryers /IU Series Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic
More informationORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.
ORTEC Compressed Air, Gas & Fluid Technologies t a l r o n m e n i l y E n v F r i e n d t r a n l y R e i g e f r INDUSTRIAL FLUID CHILLERS FC SERIES (0-00 TONS) Application Flexibility Nortec Industrial
More information120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V
Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, 70 0 90 R7 Size 70 7 9 0 90 Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V
More informationCubic unit cooler. MUC/LUC commercial range
F W Glycol ubic unit cooler MU/LU commercial range eatcraft reserves itself the right to make changes at any time without preliminary notice - Photos non-contractual The MU-LU range meets the requirements
More informationOutstanding Performance; Application Flexibility
PORTLE HILLER4EP2 SERIES Outstanding Performance; pplication Flexibility EP2 Series Portable hillers are designed for 4 to 43 ton applications. Units are available in air-cooled, water-cooled and remote
More informationORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS
ORTEC Compressed Air, Gas & Fluid Technologies HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS Energy Lean Planet Green Cycling and Non-Cycling Design Energy Efficient s Fluctuating and Intermittent Loads Capacity,0
More informationFan coil units with centrifugal fan
an coil O an coil units with centrifugal fan O 1-11 kw O upervision lus -pipe system -pipe system Vertical installation orizontal installation 3 or 6-speed motors centrifugal fans Can be integrated into
More informationAir Cooled Scroll Chiller
ir ooled Scroll hiller Midea chillers use V shape heat exchanger and single unit s capacity from 30kW to 250kW.They are divided to PS, PS-L,PS-HM and PS-HML series according to their operation ambient
More informationMODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS
MOUEL 80-10 KW OWNFLOW OOLING RU RU T ROOM UNITS T ROOM UNITS The Moducel range of high efficiency ata Room Units, are designed for high density load areas where a large cooling duty is required from a
More informationINDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)
Refrigerated ir ryer Series IF For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,
More informationRefrigerated Air Dryer
Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and
More informationRefrigerated Air Dryer
Refrigerated ir ryer E/F Series For use in Europe, sia and Oceania Standard/ E Series H HW Power supply voltage: Single-phase 230 V (50Hz) 3E 4E 6E 8E 11E 15E1 22E 37E 55E 75E ir flow capacity (m3/h [NR])
More informationULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S
ULTRA-SAFE EXP U N I T E X P L O S I O N - P R O O F S Applications Aircraft Hangars/Service Areas hemical Storage/Handling Areas oal Preparation Plants ompressor Stations Grain Elevators Oil Refineries
More informationPersonalized comfort for offices and shopping malls RANGE OPERATING LIMITS
R-c Personalized comfort for offices and shopping malls iscreet solution in centralized facilities with closed water loop asy installation in false ceiling T-XH-5-I-I SRIPTION Heat Pumps and ooling Units
More informationUltra-Safe EXP Unit Heater
INDEEO s ULTRA-SAFE EXP explosion-proof unit heater is designed with both safety and versatility in mind. Unique ULTRA-SAFE EXP features include: Industry s Lowest Ignition Temperature ode Rating: T3,
More informationNC SeriesTM. Multi-Module TMSeries NON-CYCLING REFRIGERATED COMPRESSED AIR DRYERS. Independently Verified Performance ( scfm models)
INNOVATIVE COMPRESSE AIR SOLUTIONS COMPRESSE AIR SOLUTIONS NC SeriesTM 75 2,400 scfm Models Multi-Module TMSeries 3,250 19,200 scfm Models NON-CYCLING REFRIGERATE COMPRESSE AIR RYERS Independently Verified
More informationAHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe
HU N : 07.09.356 Range: VERSO Heat Recovery ir Handling Units VERSO Plug & Play Energy Saving Smart esign Reliable & Safe VERSO ir Handling Units VERSO-S air supply units VERSO-R air handling units with
More informationAIR-COOLED SCROLL MODULAR CHILLER
M--6 IR-OOL SROLL MOULR ILLR R4 (5-5) 5z oercial ir onditioner usiness Units Midea ir onditioning and Refrigeration Sector dd: West region of Midea coercial air conditioner department, Industry venue,
More informationB. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).
Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage
More informationPURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr)
PURIFITION SOLUTIONS R-Series R cycling refrigeration compressed air dryers flow capacity: 20-2000 scfm (34-3400 Nm 3 /hr) R-Series cycling refrigeration compressed air dryers flow capacity: 20-2000 scfm
More informationCF-10A shown CF- 2A Shown
TALE LIQUID HILLE apacities rom / - Tons Air-ooled and Water-ooled 0 to Non-zone Depleting efrigerants -A EIE AI-LED -W EIE WATE-LED -0W shown -0A shown - A hown -A hown Temptek eries air-cooled and water-cooled
More informationBrute Elite Volume Water Heaters Indoor 150, ,000 BTU/Hr. Up to 97% Thermal Efficiency
rute lite Volume ater eaters Indoor 1,000 -,000 TU/r. Up to % Thermal fficiency The unit will be designed and constructed in accordance with the S oiler and Pressure Vessel ode Section IV requirements
More information.2 Section Waste Management and Disposal.
Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationMicrochannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.
Microchannel REMOTE AIR COOLED CONDENSER Technical Bulletin: MXCC_004_030817 Products that provide lasting solutions. Krack s new Microchannel Remote Air Cooled Condenser incorporates a new patented modular
More informationNC Series. Multi-ModuleSeries. Non-Cycling Refrigerated Compressed Air Dryers INNOVATIVE COMPRESSED AIR SOLUTIONS
INNOVATIVE COMPRESSE AIR SOLUTIONS NC Series 75-2,400 SCFM Models Multi-ModuleSeries 3,250-19,200 SCFM Models Non-Cycling Refrigerated Compressed Air ryers TM TM Independently Verified Performance (200-1000
More informationMicrochannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.
Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS Technical Bulletin Products that provide lasting solutions. Krack Corporation has a long tradition of leadership and
More informationPathfinder Air-Cooled Single-Screw Chiller/Heat Pump
Engineered for flexibility and performance. TM MHS-R134a-2012 Pathfinder ir-ooled Single-Screw hiller/heat Pump Super-high-efficiency series : MHS105-MHS348 ooling capacity: 393 kw 1334 kw Heating capacity:
More informationSECTION PACKAGED COMPRESSOR AND CONDENSER UNITS
SECTION 236200 - PACKAGED COMPRESSOR AND CONDENSER UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions apply
More informationDOMEKT. Residential ventilation units
OMEKT Residential ventilation units OMEKT Komfovent OMEKT OMEKT air handling units (HU) are designed for the ventilation of residential premises. OMEKT is a standardized series of the air handling units
More informationLow Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional
Now available with optional ECM Motors High Efficiency / High Reliability Low rofile Unit Cooler ublication No. 100.14 January, 2008 MEA Air Defrost - 3,900 to 39,000 BTUH Electric Defrost - 3,600 to 28,000
More informationDUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES
DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES Range 3.6 To 36.5 Tons 50Hz R22 TABLE OF CONTENT General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators
More informationCoolPro. Compressed air and gas aftercoolers (air and water-cooled configurations) Purifying your compressed air, increasing your efficiency.
oolpro ompressed air and gas aftercoolers (air and water-cooled configurations) Purifying your compressed air, increasing your efficiency. The ftercooler market has gone through a profound change in recent
More informationSECTION COMPUTER ROOM AIR CONDITIONING SYSTEMS
PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Specification Sections, apply to this Section. B. Related
More informationDUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C
DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C CONTENTS General features Page 3 Components features Pages 3 to 5 Compressors Condensers Condenser fans Evaporators Evaporator fan and drive Casing-Structure
More informationPITTSBURG STATE UNIVERSITY. HVAC and BUILDING AUTOMATION SYSTEM STANDARDS
PITTSBURG STATE UNIVERSITY HVAC and BUILDING AUTOMATION SYSTEM STANDARDS CHILLERS In new construction, liquid-cooled models are preferred for systems larger than 100 ton. o Trane, York and McQuay brands
More informationFan coil units with centrifugal fan and BLDC motor
an coil O i an coil units with centrifugal fan and C motor O i - 9 kw nergy savings and comfort in a single solution rushless motor -pipe system -pipe system Vertical installation orizontal installation
More information60 Hz. Catalogue_2016 REFRIGERATION UNITS. - Commercial Range -
60 Hz atalogue_2016 - ommercial Range - RERIGERTION UNITS ommercial monoblocks Tropicalized design for high ambient temperature up to 45º Thermostatic expansion valve Hot gas defrosting Refrigerant load
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More informationReceptacles. Wiring Devices Receptacles. Receptacle Families. Receptacle Colors. Standard Grade. Academy Series Outlets. Decorator Standard Grade
STION Wiring evices Receptacles Receptacles From decorator and standard styles to Tamper Resistant receptacles, our broad line covers virtually any need throughout a house. ll of our receptacles are designed
More informationTechnical data DHP-R. A brine-to-water building heat pump in power outputs
brine-to-water building heat pump in power outputs from to 42 kw. illed with R47 (6 ) or 134a (7 ) refrigerant dvanced control with integrated web monitoring Main components...2 Space requirements...3
More informationUNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013
SECTION 15800 - AIR HANDLING EQUIPMENT 1.1 GENERAL A. All air handlers installed shall conform to the University of Rochester specification Guideline for Semi-Custom and Pre-Engineered Air Handling Units.
More informationRefrigerated Air Dryer Large Size Series
ourtesy of M/Flodyne/Hydradyne Motion ontrol Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com Refrigerated ir Dryer Large Size Series IDF25F/50F are added! New Model IDF00F- IDF00F--W
More informationAIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)
AIR HANDLERS Central Station (CS3) (Modular AL Frame AHU) Roof Mounted (RT) CONTENTS 1. CS3 Modular Aluminium Frame AHU : Unit Types 2. Casing Structure 3. Blowers and Drives 4. Coils 5. Options and Accessory
More informationCENTRAL SPLIT UNIT UNIC
CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products
More informationLZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES
High efficiency air to water heat pumps with E.V.I. compressors -15 +63 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems
More informationPrecise Temperature Control; Compact Footprint
Precise Temperature Control; Compact Footprint The Conair EP1 Series Portable Chillers are designed for 1 to 3 ton applications. Available as air-cooled or water-cooled, with pump sizes from 1/4 to 3 Hp
More informationRapid Fault Finding Icarus 8000 series
Fault finding has become more difficult as technology has become ever more sophisticated; increased component complexity, densely populated PB's, temperature sensitive devices and mixed technology have
More informationIndustrial cooling solutions
Industrial cooling solutions Protect the Environment and your Investments The use of chilled water is essential in many industrial production and transformation processes. The range of needs varies from
More informationRefrigerated Air Dryers
Refrigerated ir Dryers Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment
More informationDryer for semi-commercial laundry applications
ryer for semi-commercial laundry applications 10 eatures alvanized steel cylinder Top, front and side panels standard available in white oor opens 180 for easy loading and unloading Oversized lint filter
More informationKnight & Charger Water Heaters
Knight & harger Water eaters rom 127-1853 l/h recovery rate Storage capacities from 109-357 litres ast recovery water heater 3 Year Storage Vessel warranty onventional flued appliance as fired storage
More informationService Information. Arcadia Electronics Introduction Supplement for Vented & Condenser Dryers. Whirlpool UK Appliances Ltd
077 ssue Nov. 0 00966 SM0068 rcadia lectronics ntroduction Supplement for Vented & ondenser ryers Service nformation including information on models fitted with the BPM Motor Whirlpool U ppliances td 0
More informationELSTON. Nosemount Cargo Heaters. Parts List ELSTON MANUFACTURING INC. Please Contact Us for Parts and Service: Another Quality Product of:
LSTON Nosemount argo Heaters Parts List nother Quality Product of: Please ontact Us for Parts and Service: LSTON MNUFTURING IN. 0 N Weber Sioux Falls, S 0 www.elstonmfg.com -00-- Version Updated 0 Table
More informationMAC-120HE-03 Air-Cooled Chiller
MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03
More informationWith air temperature adjustment function. Application example. with constant conditions to air bearings mounted on the tool. Compressed.
Thermo-dryer With air temperature adjustment function New RoHS Stable supply of temperature and pressure controlled dry clean air! Possible to supply compressed air with the same conditions and quality
More informationDEG: TWO DRYERS IN ONE, HIGHEST ENERGY ERGY SAVINGS AND MAXIMUM RELIABILITY
: TWO RYRS IN ON, HIHST NRY RY SVINS N MXIMUM RLIILITY The patented lobal Transfer System (TS) technology of MT s line of refrigeration compressed air dryers offers 2 dryers in 1, with the dual advantages
More information30GT FLOTRONIC AIR-COOLED CHILLERS
30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed
More informationConstruction Standards Page
Construction Standards Page 236313-1 SECTION 236313 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationVERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System
VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically
More informationWZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors
High Efficiency ir to Water Split System Heat Pumps With E.V.I. ompressors -20 +43 +65 HP E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor
More informationOUH Suspended Oil Unit Heater
OUH Suspended Oil Unit Heater Industrial & ommercial Heating Systems. www.powrmatic.co.uk HATIN // VNTILATION // AIR ONDITIONIN // O PRODUTS OUH Overview odels Available OUH - reeblowing Oil Unit Heater
More informationCirculation Heaters - EX
pplication irculation Heaters - RMOVL LN HTR SKT aloritech circulation heaters are suitable for use in forced flow and natural flow heating loops where a safe, lean, reliable, and efficient heating source
More informationProduct Specifications. Vertical Floor Consoles By First Co.
NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series
More informationEVAPORATIVE COOLING, a natural occurrence
EVAPORATIVE OOLING, a natural occurrence W-Tech designs and manufactures heat dissipation systems by using adiabatic technology: cooling towers, coolers and evaporative condensers. Mission Sustainable,
More informationLZT High efficiency air to water heat pumps with E.V.I. compressors
High efficiency air to water heat pumps with E.V.I. compressors -20 +43 +65 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems
More informationManual Desiccant Dryer Numbering System
atalog 9M-TK-90-3 esiccant ryer ing System Manual esiccant ryer ing System Unit Thread Pipe unction amily Type Size Options Options Options X 0 6 0 2 0 0 0 Unit unction amily Thread Type Options X Manual
More informationD. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationEC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons
E & Split Systems Water Source Heat Pump 6 to 30 tons The E, including Split Systems, provides the best combination of performance, comfort and one-of-a-kind features that satisfy the high demands of any
More information100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION
100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest
More informationResidential Geothermal Heat Pumps Geo 3000 WA
Residential Geothermal Heat Pumps Geo 3000 W Geothermal Heating & ooling 1 Residential Geothermal Heat Pumps bout the osch Group The osch Group has been a leading global supplier of technology and services
More informationProduct information. Ultrasonic air velocity meter. Continuous air flow measurement for mining applications
roduct information Ultrasonic air velocity meter ontinuous air flow measurement for mining applications ontinuous air flow measurement in mining safe and reliable resh air is of crucial importance in mining.
More informationCoolPro Compressed air and gas aftercoolers (air and water-cooled configurations)
oolpro ompressed air and gas aftercoolers (air and water-cooled configurations Purifying your compressed air, increasing your efficiency. ooling, conditioning, purifying. oolpro The ftercooler market has
More informationPrinted 2000, replaces all previous editions PAK.5231 PAK.5232 COOLING UNITS FOR CLIMATE CONTROL, COMMERCIAL REFRIGERATION AND INDUSTRIAL APPLICATIONS
Printed 2000, replaces all previous editions Kyl M (98) PK.523 PK.5231 PK.5232 OOLIN UNITS OR LIMT ONTROL, OMMRIL RRIRTION N INUSTRIL PPLITIONS Swedish cooling units. Mini, Mid The rigadon range of commercial
More information... RTU. Packaged Air to Air Heat Pump...
... RU Packaged ir to ir Heat Pump... RU... Packaged ir to ir Heat Pump... Reznor's RU range is composed of air to air heat pumps in packaged rooftop configurations, with various heat recovery options
More informationHeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 75 2,400 SCFM. Independently Verified Performance ( scfm models)
INNOVATIVE COMPRESSE AIR SOLUTIONS TRUE-CYCLING REFRIGERATE COMPRESSE AIR RYERS 75 2,400 SCFM Independently Verified Performance (200-1000 scfm models) Stainless Steel eat Exchangers www.zeks.com True-Cycling
More informationSSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL
SO TOUGH, WE GUARANTEE IT. SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL SSL SBS www.superiorrex.com SSL / SBS Series: BIG ON FEATURES; SMALL IN SIZE Contractors All SSL/SBS model blower-coil
More informationA. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.
SECTION 23 70 00- CENTRAL HVAC EQUIPMENT PART 1: GENERAL 1.1 PURPOSE: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationInfiniti Tankless Water Heater Series Featuring SRT (Scale Reduction Technology) The Infiniti Tankless Exclusive Technologies and Features
The Infiniti Tankless Exclusive Technologies and Features Standard Features SRT Scale Reduction Technology Significantly reduces the scale build-up known to result in poor performance, additional maintenance,
More informationPACKAGED AIR COOLED Product Data Catalog
PACKAGED AIR COOLED Product Data Catalog MODELS ASP-10A ASP-15A ASP-20A ASP-00P ASP-00F ASP-00G A MEMBER OF MARDUK HOLDING COMPANY, LLC The Leader in Modular Chillers ETL and CSA Approved CHILLER MODULES
More informationWIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax
WIBR SERIES Unit Coolers - Technical Catalog 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Features/Applications Century Refrigeration s WIBR Series Unit
More information30GN FLOTRONIC II AIR-COOLED CHILLERS
30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed
More informationHeatSink TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS 150 2,400 SCFM. Independently Verified Performance ( scfm models)
INNOVATIVE COMPRESSE AIR SOLUTIONS eatsink TRUE-CYCLING REFRIGERATE COMPRESSE AIR RYERS 150 2,400 SCFM Independently Verified Performance (200-1000 scfm models) Stainless Steel eat Exchangers www.zeks.com
More informationExhaust Gas Heat Exchangers
Exhaust Gas eat Exchangers eat Transfer Technology from owman eat Exchanger Technology by World Leader in eat Exchanger Technology Turning waste heat owman Exhaust Gas eat Exchangers Recovering valuable
More informationpyxis pyxisa NEW rcgroupairconditioning
Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning
More information940ESO Tankless Water Heater
ngineering Submittal Sheet Overview and ertifications LOW-L U P US Massachusetts Plumbing oard pproved ngineering Specifications Water heater shall be a Model Therm 940 SO for outdoor installation. Plant
More informationBrute Elite Hydronic Boilers Indoor 285, ,000 BTU/Hr. 95+% Thermal Efficiency
rute lite Hydronic oilers Indoor 285,000-850,000 TU/Hr. 95+% Thermal fficiency The unit will be designed and constructed in accordance with the SM oiler and Pressure Vessel ode Section IV requirements
More informationDouble Effect Exhaust Gas Driven Absorption Machine
For Future Energy & Environment erformance Data Double Effect Gas Driven Absorption Machine Double Effect Gas Driven ype (50~R) Unit CH005 CH006 CH007 CH008 CH010 CH012 CH015 CH018 CH021 CH024 CH028 CH032
More informationWITH HOT WATER HEAT 2 THRU 5 TONS SPLIT SYSTEM AHXW Series
aicoils AIR HANDLERS WITH HOT WATER HEAT 2 THRU 5 TONS SPLIT SYSTEM AHXW Series FEATURES o Air C onditioning or Heat P ump ready o P repainted galvanized steel cabinet o Internally lined with R 4.2, 1"
More informationREFRIGERATED COMPRESSED AIR DRYERS TRUE-CYCLING TM OPERATION
INNOVATIVE COMPRESSE AIR SOLUTIONS COMPRESSE AIR SOLUTIONS REFRIGERATE COMPRESSE AIR RYERS IT TRUE-CYCLING OPERATION 75-2,400 scfm Capacity Models STAINLESS STEEL EAT EXCANGERS www.zeks.com eatsink True-Cycling
More informationThreaded Venturi Vacuum Cartridges for OEM Equipment & Applications
Threaded Venturi Vacuum artridges for O quipment & pplications 200-T threaded cartridge shown in manifold block - assembled/unassembled. id & ax eries Threaded artridges with removable silencers Ideal
More information30RB /30RQ
AIR-OOLE LIQUI HILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-IALOG PLUS * Unit with low noise option 30RB9-80/30RQ0-46 Refrigerant HF-40A Nominal cooling capacity 93-78 kw Nominal heating capacity 7-0 kw
More informationRotary Screw Compressors BSD/CSD/CSDX T SFC Series
Rotary Screw ompressors SD/SD/SDX T SF Series With the world-renowned SIGM PROFILE ir deliveries from 0.87 to 5.85 m /min, Pressures 5.5 to 5 What do you look for in a compressor with variable frequency
More informationkw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit
Flexair ir cooled rooftop packaged unit 85 0 kw Main applications Large and light commercial buildings inemas, theatres Industrial buildings and logistic centers Why this choice? Energy efficient solution
More informationB. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationKELVIN Clim F497. Kelvin air conditioning
KELVIN Clim F497 Cooling Capacity: 400 ~ 1260 kw Free-Cooling Capacity: 497 ~ 1492 kw Packaged air cooled liquid chillers with free-cooling system in A class energy efficiency for outdoor installation,
More information