Air Conditioning & Refrigeration Master Catalog. Catalog CIC /USA April 2003

Size: px
Start display at page:

Download "Air Conditioning & Refrigeration Master Catalog. Catalog CIC /USA April 2003"

Transcription

1 ir onditioning & Refrigeration Master atalog atalog I /US pril 2003

2 Table of ontents Table of ontents Introduction to Parker... page 77 System 5400 Series Self-Sealing Steel... page Series Self-Sealing rass... page Series One-Shot rass... page 93 R04 Series ual-line onnectire... page 100 Process R01 Series utomotive (R134a)... page 103 R05 Multi-Purpose Process... page 105 F57 Series Stub Kit... page

3 Notes 76

4 Introduction Introduction to Parker Introduction to Parker Parker Hannifin has the broadest oupling Product offering in the market. Whether it's Quick onnect, Self-Sealing upon disconnection, rass or Steel Material, Parker has what you need. With applications ranging from room air-conditioners to cryogenic pumps, Parker has the product you are looking for. This complete line approach allows Parker to develop Value-dded ssemblies that will reduce SKUs and decrease overall tack time. ombine this with the outstanding services Parker offers and anything is possible. The Parker dvantage roadest product line Technology leader Value-dded ssembly E-ommerce Supply chain management 5500 Series Self-Sealing rass R05 Series Multi-Purpose Process 5700 Series One-Shot rass oupling Female oupling Half R01 Series utomotive R134 Process Male oupling Half oupling ssembly 77

5 Technical Information 5400 Series Self-Sealing Steel 5400 Series Self-Sealing Steel Parker s 5400 Self-Sealing Steel are used in fluid-transfer applications for easy maintenance on refrigeration and air conditioning systems. pplications can also include marine refrigeration and air conditioning systems, along with cryogenic units. pplications General fluid-transfer applications Marine refrigerant and air conditioning systems ryogenic systems ase Product 5400-S2 Male coupling half 5400-S5 Female coupling half Features and enefits Self-sealing upon disconnection maintains minimum inclusion of air and loss of fluid. Field repairable allowing an internal valve to be replaced, if needed. Steel coupling provides durability. variety of mechanical end connections available, along with sweat connections, to provide options for installation. Multiple sizes available, along with bulkhead mounting options, to match a coupling to a unique application. gency pprovals U.L. listed; File No: S2709 Specifications See hart below. ll sizes are field repairable. Standard Material: Final seal Neoprene Seal Neoprene ody Zinc-plated steel dapter Steel or rass Specifications ash Size Part escription Operating Pressure (psi) Minimum urst Pressure (psi) ir Inclusion /onnect Maximum Fluid Loss /isconnect Static onnect (psig) oupled (oz./yr) Uncoupled Without ap/plug (oz./yr) Uncoupled With ap/plug (oz./yr) Vacuum (in. Hg.) -4 Male half < 0.25 < 0.5 < Female half < 0.25 < 0.5 < Whole coupling < 0.25 < 0.5 < Male half < 0.25 < 0.5 < Female half < 0.25 < 0.5 < Whole coupling < 0.25 < 0.5 < Male half < 0.25 < 0.5 < Female half < 0.25 < 0.5 < Whole coupling < 0.25 < 0.5 < Male half < 0.25 < 0.5 < Female half < 0.25 < 0.5 < Whole coupling < 0.25 < 0.5 < Rated Flow (gpm) 78

6 Performance ata 5400 Series Self-Sealing Steel Liquid Line Pressure rop vs. Mass Flow Refrigerant R22 Pressure rop (PSI) Refrigerant Mass Flow (Kg/Hr) Refrigerant Mass Flow (Lbs/Hr) /8" oupling ody (-06) with 1/4" (-04) opper onnection, R /8" oupling ody (-06) with 1/2" (-08) opper onnection, R /2" oupling ody (-08) with 1/2" (-08) opper onnection, R22 Pressure rop (kpa) Pressure rop (psi) Press rop Versus Flow Gallons Per Minute Flow (Test Fluid MIL-H-5606 Hydraulic Oil at 100 F) Suction Line Pressure rop vs. Mass Flow Refrigerant R22 Refrigerant Mass Flow (Kg/Hr) Pressure rop (PSI) Refrigerant Mass Flow (Lbs/Hr) /2" oupling ody (-08) with ½" (-08) opper onnection, R /4" oupling ody (-12) with 3/4" (-12 opper onnection, R22 Pressure rop (kpa) 79

7 imension ata 5400 Series Self-Sealing Steel 5400-S2 Male Half No dapter 5400-S5 Female Half No dapter Neoprene oupling Size T1 T2 H1 H T2 T S /8-18UNF / S UNEF / S /16-16UN / S /4-16UN /32-20NS oupling Size T1 H1 T2 H2 H1 T2-4 1/ / / / / /32-20NS /4-16UN T1 H S14 Female Half raze Tubing dapter 5401-S17 Male Half raze Tubing dapter H1 H1 H3 H2 Neoprene oupling Size opper Size H S / S / S / S / S / S / S / S / S / S S / Neoprene oupling Size opper Size H1 H2 H S / S / S / S / S / S / S / S / S / S S / omplete oupling raze Tubing dapter H1 H2 H1 Neoprene oupling Size opper Size H1 H / / / / / / / / / / /

8 imension ata 5400 Series Self-Sealing Steel 5410-S17-No-No Male Half SE 37 (JI) Neoprene oupling Size T1 H1 H2 T S /8-18UNF /16-20UNF 5410-S /8-18UNF /16-18UNF 5410-S UNEF /16-18UNF 5410-S UNEF /4-16UNF 5410-S /16-16UN /8-14UNF 5410-S /16-16UN /16-12UN 5410-S /4-16UN /16-12UN T2 H2 H1 T S14-No-No Female Half SE 37 (JI) T2 Neoprene oupling Size T1 H1 H2 H3 T S /8-18UNF /16-20UNF 5410-S /8-18UNF /16-18UNF 5410-S UNEF /16-18UNF 5410-S UNEF /4-16UNF 5410-S /16-16UN /8-14UNF 5410-S /16-16UN /16-12UN 5410-S /4-16UN /16-12UN T1 H1 H2 H No-No (No S ) omplete oupling SE 37 (JI) Neoprene oupling Size T1 H /16-20UNF /16-18UNF /16-18UNF /4-16UNF /8-14UNF /16-12UN /16-12UN T1 H1 H1 T1 81

9 omponents 5400 Series Self-Sealing Steel Typical Male oupling Half (S2) Typical Female oupling Half (S5) Item ash Size > No. Tube O.. Size> 1/4" - 3/8" 1/4" - 5/8" 5/8" - 7/8" 7/8" - 1-3/8" Typical Male Half 1 Tubing dapter * * * *-16 2 O-Ring ssembly 5400-S S S S ody Gasket Seal Lock Washer Jam Nut Typical Female Half 8 Union Nut and ody ssembly 5400-S S S S O-Ring Valve and Sleeve ssembly 5400-S S S S O-Ring Tubing dapter * * * * ust cap (S2 half) ust cap (S5 half) *Specify O.. Tubing size of adapter required in 16th of an inch. Example: -4 coupling with 3/8" O.. tubing = 6/16 or -6. Part number is then Recommended Torque Values Recommended torque values in ft. lbs., are listed below. Maximum ulkhead Thickness oupling Size Lock Washer Installed Lock Washer Not Used ash Size raze Type or luminum dapter to ody Non-raze Type Steel or rass S2 Half to S5 Half S S S S S S S S

10 ssembly Instructions and ccessories 5400 Series Self-Sealing Steel ssembly Instructions Step 1 fter tubing or hose has been connected to adapters (1) and (12), install adapter O-rings (2) and (11)* on adapters. e sure O-rings are not twisted. Step 2 Generously lubricate adapter O-rings (2) and (11) with the system lubricant to prevent them from scuffing and tearing when coupling body is threaded on adapter. Step 3 dapter to S2 male coupling half connection.. Lubricate poppet face with system lubricant. Insert poppet valve assembly (3) into body (4). Tighten body (4) on adapter (1).. fter body and adapter make metal-to-metal contact, tighten by rotating body (4) 1/8" with respect to adapter (1) or torque to the value shown in the Torque Values table. Step 4 dapter to S5 female coupling half connection.. Lubricate O-ring (9) liberally with system lubricant. Insert valve and sleeve assembly (10) into body (8). Tighten body (8) on adapter (12).. fter body and adapter make metal-to-metal contact, tighten by rotating body (8) 1/8" with respect to adapter (12) or torque to the value shown in the Torque Values table. Step 5 oupling connection.. Generously lubricate the gasket seal (5) on the 5400-S2 male coupling half with the system lubricant.. the union nut (8) onto the S2 male coupling half. Tighten union nut to torque values shown in the Torque Values table. IMPORTNT - O NOT rotate the S5 female coupling half body during connection.. fter the coupling halves are seated, keep the bodies of the S2 male coupling half (4) and that of the S5 female coupling half (8) from rotating and tighten the union nut to the torque values shown in the Torque Values table. IMPORTNT - O NOT rotate the S2 or S5 coupling half body during connection. ulkhead Mounting S2 Half Step 1 Install lock washer (6) on S2 half, insert S2 male coupling half through bulkhead, and tighten jam-nut (7) so that lock-washer teeth are fully compressed. Note: Lock washer (6) must be between hex of S2 male half and bulkhead. *IMPORTNT: Generous lubrication is required for all gaskets and O-rings. Lubrication should match system oil and be compatible with refrigerant system ccessories ust ap and ust Plug ust ap ust Plug dapter raze oupling Size ust ap with Gasket s ust Plug with Gasket S S S S S S S S8-16 O-Ring Required oupling s Size Tube O.. Size O-Ring rass P Size /2-20 1/ /8-20 1/ /4-18 5/ / /8 dapter SE 37 (JI) O-Ring Required Tube oupling s Size O.. Size O-Ring rass Steel P Size S 7/ / S 9/ / S 9/ / S 3/4-16 1/ S 7/8-14 5/ S 1-1/ / S 1-3/

11 Technical Information 5500 Series Self-Sealing rass oupling 5500 Series Self-Sealing rass oupling Parker s 5500 Self-Sealing rass are used in fluid-transfer applications for easy maintenance on refrigeration and air conditioning systems. pplications can also include marine refrigeration and air conditioning systems, along with split refrigeration and split beverage systems. pplication Portable split-system air conditioners Split refrigeration systems Marine refrigeration systems Refrigerated dry cleaning systems everage systems ase Product 5502 Male coupling half 5505 Female coupling half Features and enefits Self-sealing upon disconnection maintains minimum inclusion of air and loss of fluid. rass coupling provides corrosion resistance. Final metal-to-metal seal provides low leakage. opper-sweat connections provide basic ends for brazing and eliminate the need for flux, simplifying the installation process. Panel mounting options are available for the unique needs of a unit. gency pprovals UL listed; File No: S2709 orrosion Resistant rass body and copper connections make corrosionrelated problems almost nonexistent. Efficient Full flow/low pressure drop design helps improve equipment efficiencies. Easy to onnect/ isconnect -together design allows easy connection and disconnection while under system pressure. Simplified Installation opper sweat connections simplify the factory installation process (eliminating the need for flux and flux residue clean up), saving you time and money. Low ir Inclusion and Refrigerant Loss Valving is designed for low air inclusion and minimal refrigerant loss during connection and disconnection. Superior Sealing Unique self-sealing valving prevents refrigerant loss when disconnected. Metal-to-metal final seal virtually eliminates refrigerant loss when connected. Reliable Stringent design standards, backed by years of experience, a wide range of existing coupling applications, and extensive testing under extreme operating conditions, provide you with the assurance that the product will perform as specified. 84

12 Technical Information 5500 Series Self-Sealing rass oupling How it Operates isconnected When disconnected, spring-loaded valve assemblies in the male and female coupling halves are sealed to prevent refrigerant loss and the inclusion of air or foreign materials. spring in the male coupling half presses the bonded poppet against sealing surface of the coupling body. Likewise, a spring in the female coupling half presses the sleeve against sealing surface of the stem valve head. n O-ring on the female sleeve prevents leakage between the sleeve and coupling body. Female oupling Half Sealing Surface Male oupling Half Sealing Surface Partially onnected s the two coupling halves are threaded together, sealing surface of the male coupling body contacts the bonded seal of the female coupling s sleeve assembly. t the same time, the stem valve head in the female coupling assembly contacts the male coupling s bonded poppet, forcing air out of the coupling. uring this stage, both coupling halves are sealed, preventing leakage of refrigerant. Female oupling Half Male oupling Half Sealing Surface Fully onnected ontinued tightening of the union nut (female coupling) draws the couplings together, and opens the fluid passage by forcing the male coupling s poppet assembly and the female coupling s sleeve assembly open. When fully coupled a metal ring located in the front of the male coupling, forms a leak-tight seal between the two coupling halves. Female oupling Half Metal Sealing Ring Male oupling Half 85

13 Technical Information 5500 Series Self-Sealing rass oupling Specifications PROUT 5500 Series Self-Sealing rass Operating Temperature Range -40 F to 250 F (-40 to +121 ) Operating Pressure Range, onnected Male & Female oupling -06, -08, -12 & -16 ody Sizes Vacuum to 750 psi (52 bar) Operating Pressure Range, isconnected Male oupling Half -06, -08, -12 & -16 ody Sizes Vacuum to 750 psi (52 bar) Female oupling Half -06 & -08 ody Sizes Vacuum to 600 psi (41 bar) -12 ody Size Vacuum to 550 psi (40 bar) -16 ody Size Vacuum to 333 psi (23 bar) Minimum urst Pressure, onnected Male & Female oupling -06, -08, -12 & -16 ody Sizes 2,700 psi (186 bar) Minimum urst Pressure, isconnected Male oupling Half -06, -08, -12 & -16 ody Sizes 2,700 psi (186 bar) Female oupling Half -06 & -08 ody Size 1,800 psi (124 bar) -12 ody Size 1,650 psi (114 bar) -16 ody Size 1,000 psi (70 bar) Maximum ir Inclusion (uring onnection) Male & Female oupling Halves -06 ody Size 0.15 cc per connection -08 ody Size 0.10 cc per connection -12 ody Size 0.20 cc per connection -16 ody Size 0.40 cc per connection Maximum Fluid Loss (uring isconnection) Male & Female oupling Halves -06 & -08 ody Sizes 0.10 cc per disconnection -12 ody Size 0.30 cc per disconnection -16 ody Size 0.20 cc per disconnection MTERILS oupling ody rass ar per STM-16, lloy 3600 onnections Refrigeration Grade opper, per STM-75, lloy Valve Stem ssembly (Female oupling) hromate Plated Steel onded Poppet (Male oupling) Neoprene onded Sleeve (Female oupling) Neoprene MTERIL OMPTIILITY + ll components, bonded poppet and sleeve, and valve stem O-Ring seal are compatible with these refrigerants and refrigerant oils: R22 & mineral oil, alkylbenzene oil, or polyolester oil R134a, R404a, R407c, R410a, or R507 & polyolester oil Vibration Resistance omplies with UL 109 External Leak Rate, onnected < 0.1 ounce (2.96 ml) of R22 refrigerant per year at -06, -08, -12 & -16 ody Sizes Operating Pressure Range External Leak Rate, isconnected -06, -08, -12 & -16 ody Sizes < 0.50 ounce (14.79 ml) of R22 refrigerant per year Without Protective Metal ap or Plug Installed -08, -12 & -16 ody Sizes < 0.25 ounce (7.39 ml) of R22 refrigerant per year With Protective Metal ap or Plug Installed* * Protective metal cap/plug not available for -06 oupling ody Size + ue to the numerous manufacturers of refrigerant oils and continuous changes of additives, compatibility cannot be guaranteed. ontact Parker for compatibility of refrigerant oils not listed. 86

14 Technical Information 5500 Series Self-Sealing rass oupling Flow ata Liquid Line Pressure rop vs. Mass Flow Refrigerant R22 and R410a Refrigerant Mass Flow (Kg/Hr) Pressure rop (PSI) (R410a) (R22) Pressure rop (kpa) (R410a) Refrigerant Mass Flow (Lbs/Hr) (R410a) (R22a) (R22) /2" oupling ody (-08) with 1/4" (-04) opper onnection, R /2" oupling ody (-08) with 1/4" (-04) opper onnection, R410a /8" oupling ody (-06) with 3/8" (-06) opper onnection, R /8" oupling ody (-06) with 3/8" (-06) opper onnection, R410a /2" oupling ody (-08) with 1/2" (-08) opper onnection, R /2" oupling ody (-08) with 1/2" (-08) opper onnection, R410a Suction Line Pressure rop vs. Mass Flow Refrigerant R22 and R410a Refrigerant Mass Flow (Kg/Hr) Pressure rop (PSI) (R22) (R410a) (R22) (R410a) (R22) (R410a) Refrigerant Mass Flow (Lbs/Hr) (R22) (R410a) /8" oupling ody (-06) with 3/8" (-06) opper onnection, R /8" oupling ody (-06) with 3/8" (-06) opper onnection, R410a /2" oupling ody (-08) with 1/2" (-08) opper onnection, R /2" oupling ody (-08) with 1/2" (-08) opper onnection, R410a /4" oupling ody (-12) with 3/4" (-12) opper onnection, R /4" oupling ody (-12) with 3/4" (-12) opper onnection, R410a " oupling ody (-16) with 1" (16) opper onnection, R " oupling ody (-16) with 1" (16) opper onnection, R410a

15 imensions 5500 Series Self-Sealing rass oupling oupling ssembly opper onnection oupling ody Inch Inch Flange to onnection onnection onnection (ash (ash Tube End epth I.. O.. Size*) mm Size*) mm E F 1/4 OS 3/ N/ OS 9.5 N/ (-04) (-06) (128.5) (121.2) (8.1) (6.4) (8.6) (18.0) (5.8) (118.45) 3/8 OS 3/ N/ OS 9.5 N/ (-06) (-06) (128.5) (121.2) (8.1) (9.7) (11.7) (18.0) (5.8) (118.45) 1/4 OS 1/ OS 12.7 (-04) (-08) (176.5 (166.6) (67.1) (7.9) (6.4) (9.7) (23.4) (5.8) (239.27) (225.54) 3/8 OS 1/ OS 12.7 (-06) (-08) (174.2) (165.4) (66.5) (7.9) (9.7) (12.0) (23.4) (5.8) (239.27) (225.54) 1/2 OS 1/ OS 12.7 (-08) (-08) (172.2) (164.3) (65.5) (9.7) (12.7) (14.9) (23.4) (5.8) (239.27) (225.54) 5/8 OS 1/ OS 12.7 (-10) (-08) (172.2) (162.3) (65.0) (9.7) (16.0) (17.9) (23.4) (5.8) (239.27) (225.54) 5/8 OS 3/ OS 19.1 (-10) (-12) (197.9) (183.9) (68.8) (12.7) (16.0) (19.1) (33.5) (5.8) (527.50) (507.34) 3/4 OS 3/ OS 19.1 (-12) (-12) (199.4) (185.4) (67.8) (15.7) (19.1) (21.7) (33.5) (5.8) (527.50) (507.34) 7/8 OS 3/ OS 19.1 (-14) (-12) (199.4) (185.4) (67.8) (19.1) (22.4) (24.6) (33.5) (5.8) (527.50) (507.34) 7/8 OS OS 25.4 (-14) (-16) (237.0) (221.7) (84.8) (19.1) (22.4) (25.8) (42.7) (5.8) (846.72) (826.35) 1 OS OS 25.4 (-16) (-16) (240.3) (225.0) (86.9) (22.4) (25.4) (28.4) (42.7) (5.8) (846.72) (826.35) 1-1/8 OS OS 25.4 (-18) (-16) (240.0) (224.8) (86.9) (22.4) (28.7) (31.4) (42.7) (5.8) (846.72) (826.35) ll dimensions in inches (mm) * ash size = copper connection size x 16 Overall isconnected Length Overall onnected Length imensions oupling ody O.. G Mounting Flange (Width) H With Mounting Flange Ounces (Grams) Weight Without Mounting Flange Ounces (Grams) 88

16 imensions 5500 Series Self-Sealing rass oupling Female oupling Half opper onnection oupling ody imensions oupling Length onnection oupling ody Inch Inch With Retaining Weight (ash (ash Plug epth I.. O.. O.. + Nut + Ounces Size*) mm Size*) mm Less Plug With Plug** E F G H J (grams) 1/4 OS 3/ OS 9.5 N/ (-04) (-06) (79.8) (69.1) (8.1) (6.4) (8.6) (18.0) (19.1) (23.9) (71.73) 3/8 OS 3/ OS 9.5 N/ (-06) (-06) (79.8) (69.1) (8.1) (9.7) (11.7) (18.0) (19.1) (23.9) (71.73) 1/4 OS 1/ OS (-04) (-08) (98.6) (93.7) (7.9) (6.4) (9.7) (23.4) (25.4) (30.2) (137.46) 1/4 OS 1/ OS S-08 (-04) (-08) (102.86) (93.7) (7.9) (6.4) (9.7) (23.4) (25.4) (30.2) (137.46) 3/8 OS 1/ OS (-06) (-08) (97.8) (93.0) (7.9) (9.7) (12.0) (23.4) (25.4) (30.2) (137.46) 3/8 OS 1/ OS S-08 (-06) (-08) (101.9) (93.0) (7.9) (9.7) (12.0) (23.4) (25.4) (30.2) (137.46) 12 OS 1/ OS (-08) (-08) (97.8) (93.0) (9.7) (12.7) (14.9) (23.4) (25.4) (30.2) (137.46) 12 OS 1/ OS S-08 (-08) (-08) (101.9) (93.0) (9.7) (12.7) (14.9) (23.4) (25.4) (30.2) (137.46) 5/8 OS 1/ OS (-10) (-08) (96.3) (91.4) (12.7) (16.0) (17.9) (23.4) (25.4) (30.2) (137.46) 5/8 OS 1/ OS S-08 (-10) (-08) (100.3) (91.4) (12.7) (16.0) (17.9) (23.4) (25.4) (30.2) (137.46) 5/8 OS 3/ OS S-12 (-10) (-12) (117.9) (103.9) (12.7) (16.0) (19.1) (33.5) (35.1) (30.2) (299.98) 3/4 OS 3/ OS S-12 (-12) (-12) (121.2) (106.4) (15.7) (19.1) (21.7) (33.5) (35.1) (41.4) (299.98) 7/8 OS 3/ OS S-12 (-14) (-12) (121.2) (106.4) (19.1) (22.4) (24.6) (33.5) (35.1) (41.4) (299.98) 7/8 OS OS S-16 (-14) (-16) (139.2) (126.0) (19.1) (22.4) (25.8) (42.7) (42.9) (50.8) (519.91) 1 OS OS S-16 (-16) (-16) (142.7) (127.3) (22.4) (25.4) (28.4) (42.7) (42.9) (50.8) (519.91) 1-1/8 OS OS S-16 (-18) (-16) (140.2) (127.0) (22.4) (28.7) (31.4) (42.7) (42.9) (50.8) (519.91) ll dimensions in inches (mm) * ash size = copper connection size x 16 ** "" in the part number denotes a plastic plug. "S" in the part number denotes a steel plug. + imension is across hex flats. 89

17 imensions 5500 Series Self-Sealing rass oupling Male oupling Half opper onnection oupling ody ** imensions oupling Length epth oupling ody Inch Inch (with Weight (ash (ash cap) epth I.. O.. O.. Length iameter + Size Ounces Size*) mm Size*) mm Less ap With ap** E F G H J K (Grams) 1/4 OS 3/ OS 9.5 N/ M (-04) (-06) (65.5) (61.0) (8.1) (6.4) (8.6) (18.0) (12.4) (21.1) (6.72) 3/8 OS 3/ OS 9.5 N/ M (-06) (-06) (65.5) (61.0) (8.1) (9.7) (11.7) (18.0) (12.4) (21.1) (6.72) 1/4 OS 1/ OS (-04) (-08) (84.1) (82.8) (7.9) (6.4) (9.7) (23.4) (15.7) (28.7) (88.08) 1/4 OS 1/ OS S (-04) (-08) (88.1) (82.8) (7.9) (6.4) (9.7) (23.4) (15.7) (28.7) (88.08) 3/8 OS 1/ OS (-06) (-08) (83.6) (82.3) (7.9) (9.7) (12.0) (23.4) (15.7) (28.7) (88.08) 3/8 OS 1/ OS S (-06) (-08) (87.6) (82.3) (7.9) (9.7) (12.0) (23.4) (15.7) (28.7) (88.08) 1/2 OS 1/ OS (-08) (-08) (82.6) (81.3) (9.7) (12.7) (14.9) (23.4) (15.7) (28.7) (88.08) 1/2 OS 1/ OS S (-08) (-08) (86.6) (81.3) (9.7) (12.7) (14.9) (23.4) (15.7) (28.7) (88.08) 5/8 OS 1/ OS (-10) (-08) (82.0 (80.8) (12.7) (16.0) (17.9) (23.4) (15.7) (28.7) (88.08) 5/8 OS 1/ OS S (-10) (-08) (99.3) (80.8) (12.7) (16.0) (17.9) (23.4) (15.7) (28.7) (88.08) 5/8 OS 3/ OS S /16-16 (-10) (-12) (117.9) (103.9) (12.7) (16.0) (19.1) (33.5) (25.1) (41.4) (207.36) 3/4 OS 3/ OS S /16-16 (-12) (-12) (100.6) (95.3) (15.7) (19.1) (21.7) (33.5) (25.1) (41.4) (207.36) 7/8 OS 3/ OS S /16-16 (-14) (-12) (100.6) (95.3) (19.1) (22.4) (24.6) (33.5) (25.1) (41.4) (207.36) 7/8 OS OS S /4-16 (-14) (-16) (118.9) (111.0) (19.1) (22.4) (25.8) (42.7) (26.2) (47.8) (306.44) 1 OS OS S /4-16 (-16) (-16) (120.9) (113.0) (22.4) (25.4) (28.4) (42.7) (26.2) (47.8) (306.44) 1-1/8 OS OS S /4-16 (-18) (-16) (120.9) (113.0) (22.4) (28.7) (31.4) (42.7) (26.2) (47.8) (306.44) ll dimensions in inches (mm) * ash size = copper connection size x 16 ** "" in the part number denotes a plastic plug. "S" in the part number denotes a steel plug. + imension is across hex flats. 90

18 ccessories Protective Plugs (ulk package, 25/package) Protective aps (ulk package, 25/package) 5500 Series Self-Sealing rass oupling oupling ody Size (ash Size*) Plastic mm Part Number ll dimensions in inches (mm) * ash size = copper connection size x 16 Length iameter Weight Ounces (Grams) 3/ ULK (-06) (18.3) (26.4) (2.68) 1/ ULK (-08) (9.9) (30.5) (1.90) Steel imensions 1/ S8-08-ULK (-08) (18.3) (25.4) (41.92) 3/ S8-12-ULK (-12) (28.7) (36.6) (137.34) S8-16-ULK (-16) (31.8) (44.5) (224.76) oupling ody Size (ash Size*) Plastic mm Part Number ll dimensions in inches (mm) * ash size = copper connection size x 16 Length iameter Weight Ounces (Grams) 3/ ULK (-06) (14.0) (23.6) (1.12) 1/ ULK (-08) (12.7) (25.7) (1.70) Steel imensions 1/ S6-08-ULK (-08) (14.2) (28.7) (30.58) 3/ S6-12-ULK (-12) (14.2) (41.4) (67.48) S6-16-ULK (-16) (19.1) (50.8) (141.20) Mounting Flange (Steel) oupling ody Size (ash Size*) mm 3/8 9.5 (-06) Part Number N/ iameter N/ imensions ircle iameter iameter Weight Ounces (Grams) 1/ (-08) (28.7) (42.9) (50.8) (13.73) 3/ (-12) (41.4) (53.9) (63.5) (20.16) (-16) (47.8) (60.5) (69.9) (20.37) N/ N/ N/ ll dimensions in inches (mm) * ash size = copper connection size x 16 91

19 Ordering Information 5500 Series Self-Sealing rass oupling How to Order 5502 oupling Type 04 opper onnection Size ap Requirements 06 oupling ody Size Product Type 5502 = Male oupling Half 5505 = Female oupling Half opper onnection (enoted xx/16) -04 = 1/4" (6.4 mm) -06 = 3/8" (9.5 mm) -08 = 1/2" (12.7 mm) -10 = 5/8" (15.9 mm) -12 = 3/4" (19.1 mm) -14 = 7/8" (22.2 mm) -16 = 1" (25.4 mm) -18 = 1-1/8" (28.6 mm) ap 0 = No ap = Includes Plastic Protective ap or Plug S = Includes Steel Protective ap or Plug oupling ody Size (enoted xx/16) -06 = 3/8" (9.5 mm) -08 = 1/2" (12.7 mm) -12 = 3/4" (19.1 mm) -16 = 1" (25.4 mm) 92

20 Technical Information 5700 Series One-Shot rass 5700 Series One-Shot rass Parker s 5700 One-Shot rass are used in fluidtransfer applications for easy installation on refrigeration and air conditioning systems. pplications typically include split air conditioning systems, split heat pumps, and manufactured homes. Specifications PROUT: 5700 Series One Shot rass oupling Operating Temperature Range -40 F to 250 F (-40 to +121 ) Operating Pressure Range, onnected Male & Female oupling -06, -08, -12 & -16 ody Sizes Vacuum to 750 psi (52 bar) Operating Pressure Range, isconnected Male oupling Half -06, -08, -12 & -16 ody Sizes Vacuum to 750 psi (52 bar) Female oupling Half -06 & -08 ody Sizes Vacuum to 600 psi (41 bar) -12 ody Size Vacuum to 550 psi (40 bar) -16 ody Size Vacuum to 333 psi (23 bar) Minimum urst Pressure, onnected Male & Female oupling -06, -08, -12 & -16 ody Sizes 2,700 psi (186 bar) Minimum urst Pressure, isconnected Male oupling Half -06, -08, -12 & -16 ody Sizes 2,700 psi (186 bar) Female oupling Half -06 & -08 ody Size 1,800 psi (124 bar) -12 ody Size 1,650 psi (114 bar) -16 ody Size 1,000 psi (70 bar) Maximum ir Inclusion (uring onnection) Male & Female oupling Halves -06 ody Size 0.15 cc per connection -08 ody Size 0.10 cc per connection -12 ody Size 0.20 cc per connection -16 ody Size 0.40 cc per connection Maximum Fluid Loss (uring isconnection) Male & Female oupling Halves -06 & -08 ody Sizes 0.10 cc per disconnection -12 ody Size 0.30 cc per disconnection -16 ody Size 0.20 cc per disconnection MTERILS oupling ody rass ar per STM-16, lloy 3600 Refrigeration Grade opper, onnections per STM-75, lloy Valve Stem ssembly (Female oupling) hromate Plated Steel onded Poppet (Male oupling) Neoprene onded Sleeve (Female oupling) Neoprene MTERIL OMPTIILITY + ll components, bonded poppet and sleeve, and valve stem O-Ring seal are compatible with these refrigerants and refrigerant oils: R22 & mineral oil, alkylbenzene oil, or polyolester oil R134a, R404a, R407c, R410a, or R507 & polyolester oil Vibration Resistance omplies with UL 109 External Leak Rate, onnected -06, -08, -12 & -16 ody Sizes < 0.1 ounce (2.96 ml) of R22 refrigerant per year at Operating Pressure Range External Leak Rate, isconnected -06, -08, -12 & -16 ody Sizes < 0.50 ounce (14.79 ml) of R22 Without Protective Metal ap or Plug Installed refrigerant per year -08, -12 & -16 ody Sizes With Protective Metal ap or Plug Installed* < 0.25 ounce (7.39 ml) of R22 refrigerant per year pplication Split air conditioning systems Split heat pumps Manufactured homes ase Product 5780 Female coupling half without charge port 5781 Female coupling half with charge port 5782 Male coupling half without charge port 5783 Male coupling half with charge port Features and enefits Single-use coupling contains a diaphragm that is pierced upon connection and folded back into the coupling to provide a high flow path and low pressure drop. Final metal-to-metal seal keeps air inclusion to a minimum. rass coupling provides corrosion resistance. opper-sweat connections provide basic ends for brazing and eliminate the need for flux, simplifying the installation process. rass sweat connections and panelmounting options are available for the unique needs of a unit. Male/female charge ports can be included for easy system diagnostics. Stub kits (F57) are also available with copper connections. gency pprovals UL listed; File No: S2709 Specifications Notes: * Protective metal cap/plug not available for -06 oupling ody Size + ue to the numerous manufacturers of refrigerant oils and continuous changes of additives, compatibility cannot be guaranteed. ontact Parker for compatibility of refrigerant oils not listed. 93

21 Technical Information 5700 Series One-Shot rass Pressure rop omparison The graphs below show significant reduction in pressure drop and associated efficiency gains utilizing Parker 5700 Series vs. standard base valves Key: Pressure rop vs. Mass Flow -8 Suction Line, Refrigerant Straight opper Tube -8 Typical ase Valve Parker oupling Key: Pressure rop vs. Mass Flow -10 Suction Line, Refrigerant Straight opper Tube -10 Typical ase Valve Parker oupling Pressure rop (psi) Pressure rop (psi) Refrigerant Mass Flow (Lbs/Hr) Refrigerant Mass Flow (Lbs/Hr) Key: Pressure rop vs. Mass Flow -12 Suction Line, Refrigerant Straight opper Tube -12 Typical ase Valve Parker oupling Key: Pressure rop vs. Mass Flow -14 Suction Line, Refrigerant Straight opper Tube -14 Typical ase Valve Parker oupling Pressure rop (psi) Pressure rop (psi) Refrigerant Mass Flow (Lbs/Hr) Refrigerant Mass Flow (Lbs/Hr) 94

22 Technical Information 5700 Series One-Shot rass esign and Operation complete 5780 Series oupling consists of the combination of male and female coupling halves. Either coupling half is available with or without a charging port, depending on the particular application. oupling Halves efore onnection iaphragms in the coupling halves provide a seal that prevents refrigerant loss before connection. The male half (right unit) contains a cutter blade, the metal refrigerant sealing diaphragm and intermediate synthetic rubber seal which prevent loss of refrigerant while the coupling is being connected. The female half (left unit) contains a metal diaphragm which is a leakproof metal closure. oupling Halves onnected Tightening the union nut draws the coupling halves together, piercing and folding both metal diaphragms back and opening the fluid passage, thereby providing minimal restriction to flow. When fully coupled, a parent metal seal forms a permanent leakproof joint between the two coupling halves preventing the loss of refrigerant to the atmosphere. The cutaway views below show male and female coupling halves joined at 20%, 50%, and 100% connection. Note the way the cutter blades pierce the diaphragms and fold them back out of the flow path. lso note the difference in the final sealing area before and after torquing. 20% connected 50% connected Final sealing area connected prior to torquing Final sealing area connected after torquing 100% connected 95

23 imensions 5700 Series One-Shot rass 5780-Size Female Half without harge Port 5781-Size Female Half with harge Port 5782-Size Male Half without harge Port 5783-Size Male Half with harge Port 96

24 Installation Instructions 5700 Series One-Shot rass Factory razing Instructions Step 1 Sparingly apply paste flux to Step 2 Step 3 the copper tube. Note: Liquid flux or excessive flux can run inside the coupling and cause corrosion. Immerse the coupling (diaphragm end) into a flowing cool water bath and female halves: Water level should be halfway up the nut and the nut hex fully immersed and 5783 male halves: Water level should fully cover the threads. Use a double tip torch to promote even heating and reduce braze time. Step 4 fter the alloy solidifies, Step 5 The couplings can be Step 6 Protector caps and plugs quench the tubing and coupling to subjected to unit test pressures up to should be installed finger tight. Overtightening reduce the temperature below 400 F. 300 psig. If pressures in excess of 300 can damage the diaphragm. Make sure the water does not enter psig are used, the protector caps and The diaphragm and O-ring can be the open charge port in the 5781 or plugs should be installed lubricated with refrigerant oil prior to 5783 half. installing the protector caps or plugs as added assurance of proper lubrication when connected at unit installation. Male-Half Installation Procedure Male half (5782) should be mounted with the hex on the inside of the unit held in place with the appropriate mounting flange. Sheet metal opening, screw hole diameter, and mounting bolt circle dimensions are included in the chart below. Recommended oupling oupling Sheet Metal Flange Mounting olt Screw Hole Size Opening ircle iameter 5782-Size-6 3/4" Size-6 3/4" Size-8 15/16" F Size /16" F Size /16" F Size /8" Size /8" Size /16" F Size /16" F ll dimensions in inches. 97

25 Installation and Reconnection Instructions 5700 Series One-Shot rass Installation Instructions Step 1 Step 2 raze coupling to clean copper tubing. Install plastic dust plug. Step 3 pply refrigeration oil to the diaphragm and threads of the couplings on the indoor unit. Step 4 onnect the line set couplings finger tight. o not use a wrench. The O-ring will seal. Step 5 Repeat steps 3 and 4 on the outdoor unit. Step 6 Evacuate and charge the line set per the manufacturer's instructions. Retighten the charge port cap. Step 7 Tighten all four coupling connections with a wrench until seated or a definite resistance is felt. Mark a line on the swivel nut and unit. Using the line as a guide, tighten an additional 1/4 turn. Step 8 Leak check the braze and coupling joints. Follow the manufacturer's instructions for start up. Reconnection Instructions Note: The O-ring is only an intermediate seal during the initial connection of a precharged unit/line set combination. The O-ring is only used for sealing between the time the diaphragm is pierced and the final metal-to-metal seal is made. The final leak-proof seal is a metal-to-metal connection made between the male and female coupling bodies. Step 1 Upon disconnection, remove O-ring. Step 2 If O-ring is missing from groove, insure O-ring is not lodged inside coupling halves and reconnect without O-ring. Step 3 Route the suction line and liquid line between the indoor and outdoor unit. Step 4 Remove protector caps and plugs. Step 5 arefully wipe coupling seats and threaded surfaces with a clean cloth, to prevent the inclusion of dirt or any foreign material in the system. Step 6 Lubricate male half diaphragm and synthetic rubber seal with system-compatible refrigerant oil. coupling halves together by hand to insure proper mating of threads. Use proper size wrenches (on coupling body hex and on union nut) and tighten until coupling bodies sea" or a definite resistance is felt. Step 7 Using a marker, mark a line lengthwise from the coupling union nut to the bulkhead. Then tighten an additional 1/4 turn; the misalignment of the line will show the amount the coupling has been tightened. This final 1/4 turn is necessary to insure the formation of a leakproof joint. If a torque wrench is used, the following torque values are recommended: oupling Size Ft/Lbs

26 ccessories and Ordering Information 5700 Series One-Shot rass Order Options harging Port ap Mounting Flange Female oupling Half Male oupling Half asic oupling Size O.. Tube Size Female oupling Half without harging Port (Includes Plug) Female oupling Half with harging Valve Port less ap and ore (Includes Plug) Male oupling Half with Protector ap less Mounting Flange Male oupling Half with harging Valve Port less ap and ore (Includes Plug) Mounting Flanges for 5782 Only olt Hole ia (#10 Screw) olt Hole Port (#14 Screw) harging Port ap harging Valve ore -6 1/ / / / F / F / F / F F / F F / F F / / / / / F F / F F / F F

27 Technical Information R04 Series ual-line onnectire R04 Series ual-line onnectire Parker s R04 ual-line onnectire are used in fluid-transfer applications for easy maintenance on refrigeration and air conditioning systems. pplications can also include portable air conditioners, split refrigeration systems, and mini-split air conditioning & heat pump systems up to 2-tons. pplication Split refrigeration systems Mini-split air conditioning and heat pump systems up to 2-tons Portable air conditioners ase Product R & Male oupling R , , & Female oupling Features and enefits Simultaneously and quickly connects both liquid and vapor lines without the use of tools. Self-sealing upon disconnection maintains minimum inclusion of air and loss of fluid. rass coupling provides corrosion resistance. opper-sweat connections provide basic ends for brazing and eliminate the need for flux, simplifying the installation process. Panel mounting options are available for the unique needs of a unit. Specifications oupling Size -6 Maximum Operating Pressure bar (psi) Minimum urst Pressure bar (psi) Vacuum Microns 50 ir Inclusion Per. Valve (cc. max.) Operating Temperature Range ( F) R22 onnected Leakage/Effusion Rating 27.6 (400) (2000) to +121 (-40 F to +250 F) <0.1 oz./yr. Reusable onnections >1000 How it Works E Liquid Line (High Pressure) Liquid or capillary lines. Vapor Line (Low Pressure) Flexible, stainless steel line withcopper tube end for easy factory installation. over Flexible protective sleeve. ondensate Flexible condensate line for water drainage. E Electrical Wiring harnesses custom-made to your exact specifications. Twin PV chamber houses flexible liquid line(s), vapor line, electrical line, and water lines for easy routing and line installation. 100

28 imensions & Installation Instructions R04 Series ual-line onnectire imension ata Installation Instructions To onnect: Step 1 Ensure that the handle on the female coupling is in a reclined position away from the mating male coupling Step 2 Retract the Release Sleeve on Female oupling and insert the mating male coupling, located on the outside unit. Step 3 Release the Release Sleeve to the lock the male coupling into places To isconnect: Step 1 Shut down the / unit and unplug the electrical power cord from the wall outlet. Step 2 Wait five minutes for the line pressure between the indoor compressor unit and outdoor condensing unit to equalize. Step 3 Pull the female coupling handle up and toward the female coupling to the full back position. Step 4 Fold the female coupling handle towards the male coupling half and push until the handle seals behind the Release Sleeve and flat against the entire coupling assembly. Step 5 lines. onnect the auxiliary electrical and condenser Step 6 onnect the electrical power cord from the / unit into the appropriate electrical wall outlet and start the / unit. Step 4 Retract the Release Sleeve on the Female oupling to release the male coupling half from the female half. Step 5 lines. isconnect the auxiliary electrical and condenser Step 6 The indoor compressor unit can now be moved to another location. 101

29 Options R04 Series ual-line onnectire Female Mounting Option Protective Transition oot Male Half Protective ap for Male Half Female Half Protective Plug for Female Half 102

30 Technical Information R01 Series utomotive R134 Process oupling R01 Series utomotive R134 Process oupling Parker s R01 utomotive Process oupling provides easy evacuating and charging of HF-134a mobile air conditioning systems. pplication Evacuating and charging of HF-134a air conditioning systems ase Product R Lowside field service coupling R Highside field service coupling *See the following page for brass and plated part numbers and configurations. Features and enefits Safety feature prevents coupling from flowing unless connected to service port. rass coupling, with or without plating, provides corrosion resistance. Red anodized knob on the high side and blue anodized knob on the low side, along with distinct sizes, assist in preventing cross-contamination between sections of the system. gency pprovals R01 UL recognized; File No. S2709 U.S. Patent No. RE34,781 Vacuum ompression Micron Level Parker Process oupling Vacuum ompression 2-1/2 Ton Split System Service Port with ore Time (Minutes) With flow equal to a 3/8" tube, Parker process couplings evacuate refrigerant in one-sixth of the time of current service ports. onnection and ctuation R01002 & R isconnected System Side Part No. Low Side R High Side R = Flow Path 2. onnected 3. Service Port Open 4. Service Port losed 103

31 imensions R01 Series utomotive R134 Process oupling R Service oupling ssembly Low Side, R134a 1.75 Open Position M14X1.5 6H 1.08 Ref 1.23 Ø 1.31 Ref Ø 1.25 Ref R Service oupling ssembly High Side, R134a 1.71 Ref Open Position 1.05 Ref M14X1.5 6H 1.23 Ø 1.31 Ref Ø 1.25 Ref Finish Side Port System Side Plated 14 mm Female Low Side R Plated 14 mm Female High Side R Plated 5/8" - 18 Male Low Side R Plated 5/8" - 18 Male High Side R Plated 7/16" - 20 Male Low Side R Plated 7/16" - 20 Male High Side R Finish Side Port System Side rass 14 mm Female Low Side R rass 14 mm Female High Side R rass 7/16" - 20 Male Low Side R rass 7/16" - 20 Male High Side R

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE

DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE DUAL VOLTAGE ICE BOX CONVERSION SYSTEM 120 VOLTS A.C. & 12/24 VOLTS D.C. MODELS: SCQT-4408F-U1-L SCQT-4408F-U1-I OWNER'S GUIDE SAWAFUJI ELECTRIC CO., LTD. GENERAL: This appliance is designed to convert

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and

More information

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C) Refrigerated ir ryer Series IF For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,

More information

Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit

Cased Aluminum Coils Dedicated Upflow / Downflow Convertible to horizontal with separately purchased kit 18-AD32D1-3 Cased Aluminum Coils "Dedicated Upflow / Downflow" Convertible to horizontal with separately purchased kit Upflow models: 4PXCAU24BS3HAA 4PXCBU24BS3HAA 4PXCBU30BS3HAA 4PXCCU30BS3HAA 4PXCBU36BS3HAA

More information

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

Cased Aluminum Convertible Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC** 18- AH44D1-4 Cased Aluminum "Convertible" Coils 4TXCB003CC3HC 4TXCB004CC3HC 4TXCC005CC3HC 4TXCC006CC3HC 4TXCC007CC3HC 4TXCC008CC3HC 4TXCD009CC3HC 4TXCD010CC3HC May be "A" or "B" ALL phases of this installation

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS SPLIT AIR CONDITIONER OUTDOOR SECTION Models: HAC481-B HAC602-B For Use With: Matching Indoor Blower Coil Units and Matching Add On Coil Units Only Bard Manufacturing Company,

More information

Technical Data. to the physical properties of

Technical Data. to the physical properties of Worldwide ontacts www.tyco-fire.com G-FIRE Figure 579 d Rigid oupling 2 Inch to 8 Inch (N50 to N200) General escription he GRINNELL G-FIRE Figure 579 d Rigid ouplings provide a rigid joint by firmly gripping

More information

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, 70 0 90 R7 Size 70 7 9 0 90 Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V

More information

Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system

Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system Bulletin ACH-GB The Air Conditioning / Refrigeration System The domestic and industrial Air Conditioning / Refrigeration

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ,t_2007 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR 505,264M (65484504) 10/07 Supersedes 09/06 COILS n _putech blications ical Litho U.S.A. RETAIN THESE

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer E/F Series For use in Europe, sia and Oceania Standard/ E Series H HW Power supply voltage: Single-phase 230 V (50Hz) 3E 4E 6E 8E 11E 15E1 22E 37E 55E 75E ir flow capacity (m3/h [NR])

More information

HEATING AND AIR CONDITIONING

HEATING AND AIR CONDITIONING WJ HEATING AND AIR CONDITIONING 24-1 HEATING AND AIR CONDITIONING TABLE OF CONTENTS page SERVICE PROCEDURES REFRIGERANT OIL LEVEL...1 REFRIGERANT RECOVERY....1 REFRIGERANT SYSTEM CHARGE...1 REFRIGERANT

More information

Technical Data. to the physical properties of

Technical Data. to the physical properties of Worldwide ontacts www.tyco-fire.com G-FIRE Figure 579 d Rigid oupling 2 Inch to 8 Inch (N50 to N200) General escription he GRINNELL G-FIRE Figure 579 d Rigid ouplings provide a rigid joint by firmly gripping

More information

TECHNICAL DATA. Wet 26a. February 22, 2009

TECHNICAL DATA. Wet 26a. February 22, 2009 February 22, 2009 Wet 26a 1. DESCRIPTION The Viking Alarm Check Valve serves as a check valve by trapping pressurized water above the clapper and preventing reverse flow from sprinkler piping. The valve

More information

UPDATED 10/24/18 CUP ACCESSORIES

UPDATED 10/24/18 CUP ACCESSORIES UPDTED 0/24/8 UP ESSORIES UPDTED 0/24/8 4:2 Dual-Flow Valves Tri-Flow Valves Flow-Sensor-Valves heck Valves one Valves Mechanical Valves Swivel Joints Tee dapters Level ompensators Dual-Flow Valves 3 Tri-Flow

More information

Function. Pressure Vessel Inspector; CRN registered Sizes 2 4

Function. Pressure Vessel Inspector; CRN registered Sizes 2 4 ISLIRT air and dirt separator series and N RISTR SI N ISO 900:000 ert. n M UNI N ISO 900:000 ert. n 000 LI 0/. N Replaces 0/ N unction ir and dirt separators are used to continuously remove the air and

More information

Refrigerated Air Dryer

Refrigerated Air Dryer T.S30-8 Refrigerated ir ryer Series IF/IU ir flow capacity Power consumption Refrigerant Increased up to the max. 40% ecreased up to the max. 40% F34a oefficient of destruction for ozone is zero. Improved

More information

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X

INSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X Installation Truck Refrigeration & Commissioning Manual: INSTALLATION AND COMMISSIONING MANUAL for Neos 100S Integra 20X, 30S, 35X, 40X, 50X Direct Drive Refrigeration Units 2017 Carrier Corporation Printed

More information

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA 18- AH39D1-4 Cased Aluminum "Convertible" Coils 2/4TXCA018BC3HCA 2/4TXCA024BC3HCA 2/4TXCB025BC3HCA 2/4TXCB031BC3HCA 4TXCB032BC3HCA 2/4TXCB036BC3HCA ALL phases of this installation must comply with NATIONAL,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2008 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR COILS 505,264M (65484504) 05/08 Supersedes 10/07 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE

More information

Manual Desiccant Dryer Numbering System

Manual Desiccant Dryer Numbering System atalog 9M-TK-90-3 esiccant ryer ing System Manual esiccant ryer ing System Unit Thread Pipe unction amily Type Size Options Options Options X 0 6 0 2 0 0 0 Unit unction amily Thread Type Options X Manual

More information

VACUUM VALVES AND HOSES

VACUUM VALVES AND HOSES VACUUM VALVES AND HOSES 5046 Vacuum Valve Two-piece 500 F (260 C) industry standard 5255 Vacuum Valve Three-piece 500 F (260 C) industry standard SS5700 Stainless Steel Vacuum Valve Three-piece 1000 F

More information

User s Information and Installation Instructions

User s Information and Installation Instructions Outdoor Air Conditioner User s Information and Installation Instructions 10 SEER Standard Efficiency Split System These units have been designed and tested for capacity and efficiency in accordance with

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Series Units RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Improper installation, adjustment, alteration, service or maintenance can cause personal injury, loss of life,

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH TXV Horizontal Slab Coils WLSH These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

Excalibur Manual. Parts Diagram - 210H. About Us. Cold Cutting Model 210

Excalibur Manual. Parts Diagram - 210H. About Us. Cold Cutting Model 210 About Us We appreciate your business! ongratulations on your new SAWYER product. We are proud to have you as our customer and will strive to provide you with the best service and reliability in the industry.

More information

Waterproof Circular Connectors

Waterproof Circular Connectors Waterproof ircular onnectors JR-W Series Product Specifications Ratings Ratings Ratings urrent rating Voltage rating Operating temperature range Storage temperature range Shell size urrent rating 13 16

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers /IU Series Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic

More information

Spare parts list. Hydraulic compactor RC

Spare parts list. Hydraulic compactor RC Spare parts list Hydraulic compactor RC 150 RC 150 Valid from serial number BGF0102397 Valid to serial number www.cp.com RC 150 Spare parts list General information This spare parts list applies to the

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Proper isposal of Your Old Refrigerator efore You Throw way Your Old Refrigerator or Freezer: Take off the doors. Leave the shelves in place so that children may not easily climb inside. Suffocation Hazard

More information

CS1000. Single Pole Plugs & Connectors up to 400A, 1000VAC Featuring: Silver-Nickel, Butt-Style Contacts. Locking Pin. Finger Guard (IP2X)

CS1000. Single Pole Plugs & Connectors up to 400A, 1000VAC Featuring: Silver-Nickel, Butt-Style Contacts. Locking Pin. Finger Guard (IP2X) New Product Announcement Issue date: 14 June 2012 CS1000 new product description Single Pole Plugs & Connectors up to 400A, 1000VAC Featuring: Silver-Nickel, Butt-Style Contacts Locking Pin Removable Unlocking

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment

More information

2016 Ideal Vacuum (505) V 1.1

2016 Ideal Vacuum (505) V 1.1 Doc. Ref. IdealCUBE-6x121416 pg. 1 User Manual Table of Contents 6x6x6 Vacuum Cube Specification Sheet...3 Assembling a Vacuum Cube system...3 Vacuum Cube Frame...3 Plate Installation...4 Mounting for

More information

V46 2-way Pressure Actuated Water Valves - Commercial Applications

V46 2-way Pressure Actuated Water Valves - Commercial Applications Pressure ctuated Water Valves V46 2-way Pressure ctuated Water Valves - ommercial pplications These pressure actuated modulating valves control the quantity of water to a condenser by directly sensing

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2016 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS Elite Series XC16 Units AIR CONDITIONER 507161-01 8/2016 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE General This

More information

Boss Fittings KORD INDUSTRIAL INC

Boss Fittings KORD INDUSTRIAL INC UFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTURING QUALITY SERVICE MANUFACTU Boss Fittings KORD INDUSTRIAL INC. 866.874.5673 Products Recommended for Steam Service Quick Disconnect

More information

HEATING AND AIR CONDITIONING

HEATING AND AIR CONDITIONING XJ HEATING AND AIR CONDITIONING 24-1 HEATING AND AIR CONDITIONING TABLE OF CONTENTS page DESCRIPTION AND OPERATION SERVICE WARNINGS AND PRECAUTIONS...1 COMPRESSOR - 2.5L VM DIESEL....3 COMPRESSOR CLUTCH

More information

Audi-Larm Audible Alarm

Audi-Larm Audible Alarm Audi-Larm Audible Alarm MAINTENANCE AND REPAIR TAL 1706 (L) Rev. 7 MSA 2017 Prnt. Spec. 10000005389(I) Mat. 10093084 Doc. 10093084 REPLACEMENT KITS AND PARTS LIST TAL 1706 (L) Rev. 7-10093084 2 Exploded

More information

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve

SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve 372 ROUTE 4 BARRINGTON, NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com SEA FROST BAITFREEZER 110-VOLT AIR-WATER Twin Valve Operation and Installation

More information

Installation Manual Mopar Engine Compartment Upgrade Kit

Installation Manual Mopar Engine Compartment Upgrade Kit Installation Manual 64-75 Mopar Engine Compartment Upgrade Kit Congratulations... You have just purchased the highest quality, best performing A/C system upgrade ever designed for your Classic Vehicle.

More information

Thermostatic mixing valves with replaceable cartridge for centralized systems

Thermostatic mixing valves with replaceable cartridge for centralized systems Thermostatic mixing valves with replaceable cartridge for centralized systems series REGISTERED BS EN ISO 9: Cert. n FM UNI EN ISO 9: Cert. n / N Replaces /9 N Function The thermostatic mixing valve is

More information

DAD-500 (130026) DESICCANT AIR DRYING SYSTEM

DAD-500 (130026) DESICCANT AIR DRYING SYSTEM SERVICE BULLETIN SB---O Replaces SB---N DAD-00 (00) DESICCANT AIR DRYING SYSTEM Air In 0 The CFM DAD-00 Desiccant Air Drying System is designed to be a point of use system. It is capable of removing dirt,

More information

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS Classification: Reference: Date: HA94-005 NTB94-091 September 26, 1994 SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS APPLIED VEHICLE(S): All models except Quest equipped with a retrofitted A/C system SERVICE

More information

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant

More information

Ductless Split Air Conditioner

Ductless Split Air Conditioner Ductless Split Air Conditioner Installation Manual Indoor HSU09VHG(DB)-W HSU12VHG(DB)-W HSU18VHH(DB)-W HSU24VHG(DB)-W Outdoor HSU09VHG(DB)-G HSU12VHG(DB)-G HSU18VHH(DB)-G HSU24VHG(DB)-G Table of Contents

More information

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

INSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES 11-AC11D2-5 INSTALLER'S GUIDE ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES Models: Condensing Units 2A7A5024-048, 2A7A4018-060, 2A7A2018-060 & 2A7A1018-060 IMPORTANT

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 06-060 KMS0772-2472 ENG 3/17/06 2:50 PM Page a INSTLLTION INSTRUTIONS Inverter Multi Split System ir onditioner OOL/ RY Model This air conditioner uses the new refrigerant R410. For Outdoor Unit ontents

More information

Series 20 Dual Check Backflow Preventers

Series 20 Dual Check Backflow Preventers Series 20 Dual Check Backflow Preventers Excellence Matters Specify It! A Division of Watts Regulator Company 427 North Market Blvd Suite #9 Sacramento, CA 9584 Phone: 96-928-02 Fax: 96-928-9 www.amesfirewater.com

More information

INSTALLATION INSTRUCTIONS 30" (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN

INSTALLATION INSTRUCTIONS 30 (76.2 CM) ELECTRIC SINGLE AND DOUBLE BUILT-IN OVEN INSTLLTION INSTRUTIONS 30" (76.2 M) LTRI SINGL N OUL UILT-IN OVN Table of ontents UILT-IN OVN SFTY...2 INSTLLTION RQUIRMNTS...3 Tools and Parts...3 uilt-in Oven Location Requirements...3 Water Filtration

More information

HS25 SERVICE UNIT INFORMATION

HS25 SERVICE UNIT INFORMATION SERVICE UNIT INFORMATION HS25 Corp. 9327-L3 Litho U.S.A. HS25 SERIES UNITS The HS25 is a high efficiency residential split system condensing unit which features a scroll compressor. It operates much like

More information

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA TXV Coils for Manufactured Housing EMA NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance,

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir Dryers Series F/U Standard/High Temperature ir Inlet Type Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,

More information

Technical Review. Remote Condenser Cuber. Enhanced Refrigeration and Water Systems. CM 3 Technology. of a. with. using. models included are:

Technical Review. Remote Condenser Cuber. Enhanced Refrigeration and Water Systems. CM 3 Technology. of a. with. using. models included are: Technical Review of a Remote Condenser Cuber with Enhanced Refrigeration and Water Systems using CM 3 Technology models included are: CME1356 shown on BH900 CME456, CME1056, CME1356, CME1656 and CME2006

More information

16. Hose Replacement. Disconnect power supply to the AR400.

16. Hose Replacement. Disconnect power supply to the AR400. 16. Hose Replacement The AR400 is equipment with external hoses such as R-12 Low and High Service hoses, R-134 Low and High Service hoses, Tank hoses and vacuum pump hose. The unit also utilizes internal

More information

EVAPORATOR COILS Installation Manual CCG, VCG, MCG M Series Coils

EVAPORATOR COILS Installation Manual CCG, VCG, MCG M Series Coils EVAPORATOR COILS Installation Manual CCG, VCG, MCG M Series Coils www.marsdelivers.com INSTALLATION GUIDE CCG Series - Uncased Upflow/Downflow Coils VCG Series - Cased Upflow/Downflow Coils MCG Series

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Modular Crescent Cuber Models KM-900MAH50 KM-900MRH50 A Superior Degree of Reliability INSTRUCTION MANUAL www.hoshizaki.com Issued: 6-25-2008 IMPORTANT Only qualified service technicians

More information

Hose. Propane Hose. 1 X-treme Low Temp Bobtail Hose. Large Transfer Hose. Construction Tube: Cover: Reinforcement: Temp. Range:

Hose. Propane Hose. 1 X-treme Low Temp Bobtail Hose. Large Transfer Hose. Construction Tube: Cover: Reinforcement: Temp. Range: Propane For liquid or gaseous transfer of propane. 350 lb working pressure. All sizes are UL21 and CGA Type 1 approved. Cover is pin pricked for gas dissipation. I.D O.D Spirals Lbs per ft..610.15.760.22

More information

REFRIGERANT PIPING SYSTEM

REFRIGERANT PIPING SYSTEM PART 1 GENERAL 1.01 DESCRIPTION A. The requirements of this section apply to the refrigerant piping system connecting refrigeration and HVAC equipment specified in other sections of these specifications.

More information

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F

OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F OPERATING AND MAINTENANCE MANUAL FOR INSTANTANEOUS STEAM FIRED WATER HEATER ELECTRIC HEATER COMPANY BASE MODEL F Edition 2013 HUBBELL ELECTRIC HEATER COMPANY P.O. BOX 288 STRATFORD, CT 06615 PHONE: (203)

More information

BALANCED PORT Q-VALVE

BALANCED PORT Q-VALVE March 2001 / BULLETIN 10-10-6 ELEMENT BALANED PORT Q-VALVE ARTRIDGE BODY Page 2 / BULLETIN 10-10-6 Introducing the Balanced Port -Valve The BQ combines the flexibility of the replaceable cartridge style

More information

The Next Generation of Greenfield Connectors. Our flex System is Your Solution for Electrical Runs

The Next Generation of Greenfield Connectors. Our flex System is Your Solution for Electrical Runs 1/2 to 4 Solid Steel or luminum The Next Generation of Greenfield onnectors SPE-flex Our flex System is Your Solution for Electrical Runs connectors GURNTEED to Save Time On Every onnection You Make. Patent

More information

Powers TM Controls TH 188 Unit Mounted Thermostat

Powers TM Controls TH 188 Unit Mounted Thermostat Powers TM Controls Technical Instructions Document No. 155-064P25 TH 188-2 Description The is a remote bulb, gradual acting pneumatic instrument which maintains a pre-selected temperature by positioning

More information

50 Disassembly and assembly Cab and its attachments

50 Disassembly and assembly Cab and its attachments When adjustment is needed after performing check in step 8; 3) Close front window assembly (1). 4) Loosen locknuts (26) of right and left rubber stoppers (24) and move the stoppers backward so that front

More information

PRELIMINARY INSTALLATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento - Installation/Rev- #1/56

PRELIMINARY INSTALLATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento - Installation/Rev- #1/56 INSTALLATION Carrier Transicold Europe 03/09/07 Viento - Installation/Rev- #1/56 INSTALLATION Table of content Introduction...4 Preparation before installation...5 Vehicle partition... 6 Box preparation...7

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

WHEELED STORED PRESSURE

WHEELED STORED PRESSURE OWNERS SERVICE MANUAL NO. 19795 INSTALLATION, OPERATING & SERVICING INSTRUCTIONS All fire extinguishers should be installed, inspected and maintained in accordance with the National Fire Protection Association

More information

REFRIGERATION PARTS SOLUTION

REFRIGERATION PARTS SOLUTION REFRIGERATION PARTS SOLUTION Do It Yourself Kit Assembly and Installation Manual Danfoss Retrofit Compressor BD2.0F, BD2.5F, or BD3.0F to BD50F Part Number 011-1010 Manual Version 1.0 - December 2008 TABLE

More information

CIRRUS AIRPLANE MAINTENANCE MANUAL

CIRRUS AIRPLANE MAINTENANCE MANUAL COOLING 1. DESCRIPTION On aircraft serials 183 and subsequent, an optional air condition system is available. This section contains the maintenance practices pertinent to this system. Cabin ventilation

More information

Horizontal Scroll (Fixed speed)

Horizontal Scroll (Fixed speed) Horizontal Scroll () ZS S Rated Output: W~,W Low Height due to Horizontal Type. % Lower ompared to Rotary Type, 55% Lower ompared to Reciprocating Type (7W) pplications: ommercial Refrigeration, Show ase

More information

USER MANUAL UN-200V / UN-200VH

USER MANUAL UN-200V / UN-200VH USER MANUAL UN-200V / UN-200VH CONTACT US PHONE/FAX Toll Free: 800.465.1004 Phone: 801.486.1004 Fax: 801.486.1007 ADDRESS LACO Technologies, Inc. 3085 West Directors Row Salt Lake City, UT 84104 WEB www.lacotech.com

More information

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for T-333 Manual INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for Rooftop Energy Storage Systems (ESS) AIR COOLING UNIT 77-62186-00 THRU -04 & 77-62203-00 T-333 REV. 03/2012 2012 Mobile Climate Control

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS 2008 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS Merit Series 13ACX Units RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Improper installation, adjustment, alteration, service

More information

Aerospace Linear Variable Differential Transformers Single Channel, Dual Parallel, & Dual Tandem Series Issue 1. Datasheet

Aerospace Linear Variable Differential Transformers Single Channel, Dual Parallel, & Dual Tandem Series Issue 1. Datasheet erospace Linear Variable ifferential Transformers Single hannel, ual Parallel, & ual Tandem Series ESRIPTION erospace esign Engineers working on flight controls, engines, nose wheel steering and pilot

More information

DRYAIRE DESICCANT SYSTEM MODEL 6760

DRYAIRE DESICCANT SYSTEM MODEL 6760 MODEL 6760 THE SPRAY GUN PEOPLE FOR PRODUCT INFORMATION CALL: 1-800-742-7731 System Description Sharpe s DRYAIRE Desiccant Air Drying System is the painter s insurance for removing dirt, water, oil, and

More information

Liebert Prop Fan Condensing Unit

Liebert Prop Fan Condensing Unit Liebert Prop Fan Condensing Unit 50 Hz and 60 Hz Installer/User Guide Technical Support Site If you encounter any installation or operational issues with your product, check the pertinent section of this

More information

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS

Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS INTRODUCTION Please note that HUD Manufactured Home Construction and Safety Standard Section 3280.714, paragraph (a) and subparagraph

More information

Sealed Type Liquid Line and Suction Line Specifications

Sealed Type Liquid Line and Suction Line Specifications CATALOG 0 Page,, 4a, 404A, 407C, 40A, 0, 07 Also Compatible with Refrigerants, 4,, 40A & B, 40A & B, 408A, 409A The universal acceptance of the Catch-All Filter-Drier is due to its unique molded porous

More information

an ISO 9001:2015 Registered Company

an ISO 9001:2015 Registered Company an ISO 9001:2015 Registered Company Mark IV (672001-VHY) 18865 Goll St. San Antonio, TX 78266 Phone: 800-862-6658 Sales: sales@vintageair.com Tech Support: tech@vintageair.com www.vintageair.com 902001-VHY

More information

Ductless S plit Air Conditioner

Ductless S plit Air Conditioner Ductless S plit Air Conditioner Installation M anual Indoor AW09ES2VH* AW12ES2VH* AW18ES2VH* AW24ES2VH* AW09TE1VH* AW12TE1VH* AW18TE2VH* AW24TE2VH* Outdoor 1U09ES2VHA 1U12ES2VHA 1U18ES2VHA 1U24ES2VHA 1U09TE1VHA

More information

Orbit ArizonaMist. Installation ra

Orbit ArizonaMist. Installation ra Orbit rizonamist Installation Guide 53251-26 r WELOME Thank you for choosing Orbit rizona mist. In the following pages you will find: Step-by-Step Installation Guidelines ssembly and Installation rawings

More information

Catalog No. 108-C. Steam Traps

Catalog No. 108-C. Steam Traps atalog No. 8- Steam Traps Inverted bucket, float and thermostatic, thermostatic and controlled disc steam traps in carbon steel, stainless steel, forged steel and cast iron. ringing Energy own to Earth

More information

568X, 587X, 588X Series

568X, 587X, 588X Series Please read and save this Repair Parts Manual. Read this manual and the General Operating Instructions carefully before attempting to assemble, install, operate or maintain the product described. Protect

More information

ICE MAKER. Use & Care Guide B. Table of Contents... 2

ICE MAKER. Use & Care Guide B. Table of Contents... 2 IE MKER Use & are Guide Table of ontents... 2 2313687 TLE OF ONTENTS IE MKER SFETY...2 INSTLLTION INSTRUTIONS...3 Unpack the Ice Maker...3 Location Requirements...3 Electrical Requirements...3 Water Supply

More information

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO

ISO9001:2008 Cert Certified FIRE HYDRANTS. since SFFECO ISO9001:2008 Cert. 403 Certified FIRE HYDRANTS SFFECO since www.sffeco.com DRY BARREL FIRE HYDRANT Meets all applicable parts of ANSI/AWWA C502 standard UL Listed (EX16453) and FM Approved (FM1510) 250

More information

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT Refrigerating Desiccant High polymer membrane dryer VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT JIS symbol Air filter Auto. drain (Module unit) (Separate) Compact Precise (Related

More information

HDLV 55-Gallon Powder Drum Unloader

HDLV 55-Gallon Powder Drum Unloader Instruction Sheet P/N 07333 0 HDLV -Gallon Powder Drum Unloader Description See Figure. The HDLV -gallon powder drum unloader uses a Prodigy HDLV High Capacity pump to supply virgin powder to a powder

More information

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS TABLE OF CONTENTS 1. Warnings & Component Match-Up............................................ 2 2. Unit Specifications..........................................................

More information

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description Worldwide Contacts www.tyco-fire.com Model AV--00 Alarm Valve With and Without Model RC- Retard Chamber European Conformity Valve Trim General Description The TYCO Model AV--00 Alarm Valves DN, DN0, DN0,

More information

13-1. Temperature Regulator

13-1. Temperature Regulator -1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details

More information

M7100 Pressure Transducer

M7100 Pressure Transducer SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces

More information

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings. DIVISION 21 21 05 00 COMMON WORK RESULTS FOR FIRE SUPPRESSION PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe, fittings, sleeves, escutcheons, seals, and connections for sprinkler systems. 1.2 RELATED REQUIREMENTS

More information

SERVICE MANUAL FOR MODEL RM-10

SERVICE MANUAL FOR MODEL RM-10 SERVICE MANUAL FOR MODEL RM-10 REQUIRED TOOLS CORDLESS DRILL COPPER CUTTING TUBE 1/2 OPEN WRENCH SOLDERING IRON SCREWDRIVER SET WITH 9/32 SOCKET VISE GRIP PIERCING VALVE PRECISION FLAT BLADE SLOTTED SCREWDRIVER

More information

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS English Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Instruction Manual

More information

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems

More information

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M 2004 Lennox Industries Inc. Dallas, Texas KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04 Supersedes 503,249M Litho U.S.A. COMPRESSOR REPLACEMENT KIT INSTALLATION INSTRUCTIONS FOR COMPRESSOR

More information

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description Technical Services 800-381-9312 +1-401-781-8220 www.tyco-fire.com Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description The TYCO Model ESFR-17 Dry

More information

Operations and Maintenance Manual

Operations and Maintenance Manual IMPORTANT: READ THIS MANUAL THOROUGHLY BEFORE INSTALLING AND OPERATING UNIT. INSURE THERE IS ALWAYS LUBRICATING OIL IN THE FRONT FILTER LUBRICATOR FOR THE FLUID PUMP AIR MOTOR. CHECK OIL LEVEL REGULARLY

More information

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings. SECTION 15481 COMPRESSED AIR SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Pipe and pipe fittings, including valves, unions and couplings. B. Air compressor. C. After cooler. D. Refrigerated air dryer.

More information