V46 2-way Pressure Actuated Water Valves - Commercial Applications

Size: px
Start display at page:

Download "V46 2-way Pressure Actuated Water Valves - Commercial Applications"

Transcription

1 Pressure ctuated Water Valves V46 2-way Pressure ctuated Water Valves - ommercial pplications These pressure actuated modulating valves control the quantity of water to a condenser by directly sensing pressure changes in a refrigerant circuit. The valves can be used in non-corrosive refrigerant systems. mmonia power elements and valves designed for salt-water applications are available. The valves have a quick opening characteristic and open on pressure increase (direct acting). Reverse acting (close on pressure increase) is possible. eatures zpressure balanced valve design zpressure actuated z3/8, 1/2, 3/4 are angled body type valves with high Kv value z3/8 up to 2 pressure valves all range types zquick opening valve characteristics zno close fitting or sliding parts in water passages zasy to disassemble. ll parts can be replaced zspecial bronze bodies and monel parts zpower elements with stainless steel bellows available zwide range of pressure connection styles znickel plated seats available for 3/8, 1/2, and 3/4 valves zirect/reverse action imensions in mm Valve Size 3/ / / a (excl. valve depressor) 1: cm capillary 2: 7/16-20 UN flare nut 34 1: cm capillary 2: 1/4 tube for braze connection (incl. valve depressor mounted into machined flare) 1: cm capillary 2: 1/4 tube for braze connection 3: copper sealring 15 1/4-18NPT (female) 5 7/16-20 UN 207

2 Pressure ctuated Water Valves V46 Ordering odes V V (bar) ody 5 18 ngled Size Thread according to ISO 228 apillary Length (cm) dditional eatures It is possible to change 13 into 45 by ordering KIT031N600 V /8 100 Nickel plated seat/longer capillary V46 99 V V V /2 34 Solder connection/ 062 id.cap With special washer to prevent waterhammer at low flow capacity Nickel plated seat/solder connection.040 i.d.cap./solder connection V /4 V Solder connection V V V V V High range V ngled 5 3/ Nickel plated seat, high range. With washer to prevent waterhammer at low flow capacity Nickel plated seat, high range Nickel plated seat, high range. With washer to prevent waterhammer at low flow capacity V Nickel plated seat, high range 1/2 V Solder connection, high range V High range V V /4 13 Nickel plated seat, high range V High range 208

3 Pressure ctuated Water Valves V46 imension in mm Valve Size ¼ Ordering odes V (bar) ody Size Thread according to ISO 7-Rc apillary Length 5 V V V Straight V ¼ V V V ¼ dditional eatures It is possible to change 13 into 45 by ordering KIT031N600 High range 209

4 Pressure ctuated Water Valves V46 G H J I imensions in mm Valve Size G H I J 1½ ½ Ordering odes (bar) ody Size IN2533 lang onnections apillary Length V46R V46R ½ 13 V46S V46S V46T V46T Straight 2 2½ dditional eatures It is possible to change 13 into 45 by ordering KIT031N

5 Pressure ctuated Water Valves V46 imension in mm Valve Size 3/ / / ¼ Ordering odes V (bar) ody Size thread according to ISO 228 3/8 V /2 V / V V ¼ V Straight V /8 13 apillary Length V / V V /4 140 Longer capillary V V ¼ 1 Longer capillary dditional eatures It is possible to change 13 into 45 by ordering KIT031N

6 Pressure ctuated Water Valves V46 G H J I imensions in mm Valve Size G H I J 1½ ½ (bar) ody Size IN flange connections Ordering odes V46R-9510 V46R ½ 13 V46S V46S V46T V46T Straight 2 2½ apillary Length 5 212

7 Pressure ctuated Water Valves V46S Pressure ctuated Water Valves, Low low refrigeration components The V46S is a direct acting, all range, pressure actuated modulating valve, used to control the waterflow to a condenser by directly sensing pressure changes in a non-corrosive refrigerant circuit. The V46S is specially designed for use on equipment requiring a low condenser waterflow such as icemakers, small heatpumps and watercoolers. The springhousing and power element are rolled to the valve body. Rubber diaphragms seal the water away from the range spring and bellows part so these are not submerged in water where they would be subject to sedimentation and corrosion. The valve can be ordered style 5 (without capillary), style 13, style 34 and style (incl. cm capillary). The capillary part will be delivered separated from the valve. eatures zvalve designed for low flow z ll range power element and spring housing zsmall dimensions zpressure actuated zvarious pressure connection style zhigh refrigerant pressure resistant bellows imensions in mm (bar) ody SizeThread according to ISO 228 apillary Length Ordering odes V46S V46S-9110 apillary separate V46S Straight 3/8 V46S apillary separate V46S-99 V46S dditional eatures It is possible to change 13 into 45 by ordering KIT031N600 apillary soldered to power element apillary soldered to power element 213

8 Pressure ctuated Water Valves V48 3-way Pressure ctuated Water Valves refrigeration components These watervalves are especially designed for condensing units cooled either by atmospheric or forced draft cooling towers. They may be used on single, or multiple condenser hook-ups to the tower. The type V48 valve senses the compressor head pressure and allows cooling water to flow to the condenser, to by-pass the condenser, or to allow waterflow to both condenser and by-pass line in order to maintain correct refrigerant head pressure. further advantage of this system is that the 3-way valve permits a continuous water flow to the tower so the tower can operate efficiently with a minimum of maintenance on nozzles and wetting surfaces. The valves can be used in non-corrosive refrigerant systems. mmonia power elements and valves designed for salt-water applications are available. The valves have a quick opening characteristic. eatures zpressure balanced design zree movement of all parts zasy manual flushing zhigh Kv values zpressure actuated zan be used as mixing or diverting valve Port 1 imensions in mm Valve Size G H I J ommercial type 1/ / ¼ Maritime type 3/ G H I J Port 2 Port 3 Plugged Ordering odes (bar) ody Size Thread ommercial type V /2 V according to ISO 7-Rc 13 Straight V /4 V according to ISO 7-Rc apillary Length dditional eatures It is possible to change 13 into 45 by ordering KIT031N600 V V according to ISO 7-Rc 13 V Straight odies in line (port 3 below port 2) V ¼ V according to ISO 7-Rc 13 V Straight Maritime types 3/4 according to ISO Seawater resistant

9 Pressure ctuated Water Valves V Port 3 Port 2 Port ommercial types Ordering odes (bar) ody Size Thread according to ISO 7-Rc dditional eatures It is possible to change 13 into 45 by ordering KIT031N600 V Straight 1 1/

10 Pressure ctuated Water Valves V246 and V248 Water Regulating Valves for High Pressure Refrigerants refrigeration components The V246 & V248 Series 2-way and 3-Way Pressure-ctuated Water-Regulating Valves for High-Pressure Refrigerants regulate water flow and control refrigerant head pressure in systems with single or multiple watercooled condensers. These valves have an adjustable opening point in a refrigerant pressure range of 200 to 400 psig (13.8 to 27.6 bar). These Series valves are designed specifically for condensing units cooled either by atmospheric or forced draft cooling towers. They are used on single or multiple condenser hook-ups to the tower to provide the most economical and efficient use of the tower. V246 & V248 valves may be used with standard non-corrosive or ammonia refrigerants. or applications where the coolant may be corrosive to the internal parts, maritime models are available, which have nickel copper (Monel ) internal parts. eatures zno lose itting or Sliding Parts in Water Passages zccessible Spring ztake-part onstruction zpressure-alanced esign zorrosion-resistant Material for Internal Parts Standard Production Models to 27.6 bar Product odes onstruction Valve Size and onnection lement Shipping Weight (kg) V246G1001 3/8 in. SPP Screw, ISO V246G1001 1/2 in. SPP Screw, ISO V246G1001 3/4 in. SPP Screw, ISO V246G1001 irect cting, ommercial 1 in. SPT Screw, ISO V246G /4 in. SPT Screw, ISO V246GR /2 in. lange, IN V246GS in. lange, IN V246H1001 3/8 in. SPP Screw, ISO V246H1001 1/2 in. SPP Screw, ISO V246H1001 3/4 in. SPP Screw, ISO V246H1001 irect cting, Maritime 1 in. SPT Screw, ISO V246H /4 in. SPT Screw, ISO V246HR /2 in. lange, IN V246HS in. lange, IN /16-20 UN 216

11 Pressure ctuated Water Valves V246 V246 Screw onnection Valves ommercial Service - imensions imension in mm Valve Size 3/ / / V246 Screw onnection Valves ommercial Service - imensions imension in mm Valve Size / V246 Screw onnection Valves Maritime Service - imensions Port 1 Port 2 imension in mm Valve Size 3/ / / /

12 Pressure ctuated Water Valves V248 Standard Production Models to 27.8 bar Product odes onstruction Valve Size and onnection lement Shipping Weight (kg) V248G1001 1/2 in. SPT Screw, ISO V248G1001 3/4 in. SPT Screw, ISO V248G1001 irect cting, ommercial 1 in. SPT Screw, ISO V248G /4 in. SPT Screw, ISO V248G /2 in. SPT Screw, ISO V248H1001 irect cting, Maritime 3/4 in. SPP Screw, ISO /16-20 UN Port 1 Port 2 Port 3 Plugged 1/2 in. through 1-1/4 in. - imensions imensions in mm Valve Size 1/2 in /4 in in /4 in / 2 in. - imensions Port Port 3 Port 1 INLT imensions in mm Valve Size 1-1/2 in

V46. Pressure actuated water valves. Refrigeration components Modulating water valves. Catalogue page

V46. Pressure actuated water valves. Refrigeration components Modulating water valves. Catalogue page 2-way pressure actuated water valves - ommercial applications These pressure actuated modulating valves control the quantity of water to a condenser by directly sensing pressure changes in a refrigerant

More information

V246 Series Two-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

V246 Series Two-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants V246 Series Two-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants Description The V246 Series Two-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

More information

V48 Series 3-Way Water Regulating Valves For Cooling Tower Systems

V48 Series 3-Way Water Regulating Valves For Cooling Tower Systems Product/Technical Bulletin V48 Issue Date 0512 V48 Series 3-Way Water Regulating Valves For Cooling Tower Systems Application IMPORTANT: The V48 Series Water Regulating Valve is intended to control water

More information

Opening Point Adjustment Range psig (kpa) Commercial Type Non-Corrosive RefrigerantsS (R) 160 to 260 (1103 to 1793) 70 to 150 (483 to 1034)

Opening Point Adjustment Range psig (kpa) Commercial Type Non-Corrosive RefrigerantsS (R) 160 to 260 (1103 to 1793) 70 to 150 (483 to 1034) Repair Parts V43 Series Description The V43 is a pilot pressure actuated modulating valve for use on water cooled condensers that require a large flow capacity. Valves open on pilot pressure increase.

More information

Dynamic thermostatic radiator valves DYNAMICAL

Dynamic thermostatic radiator valves DYNAMICAL ynamic thermostatic radiator valves YNMIL -----7 series RIT ISO 9 M 6 /7 G unction The YNMIL valve allows the automatic dynamic balancing and pressure-independent adjustment of the thermal medium in the

More information

V246 Series 2-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

V246 Series 2-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants Code No. LIT-1900575 Issued June 19, 2009 V246 Series 2-Way ressure-actuated Water-Regulating Valves for High-ressure Refrigerants Description The V246 Series 2-Way ressure-actuated Water-Regulating Valves

More information

IDU22C, 22C1, 37C, 37C1, 55C, 75C

IDU22C, 22C1, 37C, 37C1, 55C, 75C Refrigerated ir ryer Series IU edium IU, 1, 7, 71, 55, 75 () () () () () Run light Operation (ftercooler) Stop (ftercooler) Outlet air pressure gauge vaporation () (I) () Terminal block () () P rain port

More information

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, 70 0 90 R7 Size 70 7 9 0 90 Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V

More information

Water Jet Exhausters and Compressors

Water Jet Exhausters and Compressors s and ompressors Single and Multi-Nozzle Types For vacuum pumping and mixing operations Schutte & Koerting water jet exhausters are simple, efficient and versatile devices for vacuum pumping or mixing

More information

Manual Desiccant Dryer Numbering System

Manual Desiccant Dryer Numbering System atalog 9M-TK-90-3 esiccant ryer ing System Manual esiccant ryer ing System Unit Thread Pipe unction amily Type Size Options Options Options X 0 6 0 2 0 0 0 Unit unction amily Thread Type Options X Manual

More information

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

SOLENOID VALVES FOR REFRIGERATING SYSTEMS SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97/23/EC, Article

More information

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant

More information

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C) Refrigerated ir ryer Series IF For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,

More information

Quality Heat Exchangers

Quality Heat Exchangers Quality Heat Exchangers Brazed Plate Heat Exchangers Universal solutions for industrial and domestic applications With partnership into the future FUNKE is a leader in the development and production of

More information

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT Refrigerating Desiccant High polymer membrane dryer VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT JIS symbol Air filter Auto. drain (Module unit) (Separate) Compact Precise (Related

More information

49 Danfoss Thermostat Kits Ranco Varifix Kits

49 Danfoss Thermostat Kits Ranco Varifix Kits Danfoss Thermostat Kits Code Type To Suit E005 NO-1 Kit Refrigerator E006 NO-2 Refrigerator Push/Defrost E007 NO-3 Fridge Freezer/Larder Fridge E008 NO-4 Absorption Refrigerator E009 NO-5 Freezer E010

More information

Air Conditioning & Refrigeration Master Catalog. Catalog CIC /USA April 2003

Air Conditioning & Refrigeration Master Catalog. Catalog CIC /USA April 2003 ir onditioning & Refrigeration Master atalog atalog I-2003-1/US pril 2003 Table of ontents Table of ontents Introduction to Parker... page 77 System 5400 Series Self-Sealing Steel... page 78 5500 Series

More information

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Catalog. Self-operated Regulators Volume 2 Temperature Regulators Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure

More information

64 66 Electronic Expansion Valve. 68 Q Series. 70 S Series T Series O Series R Series Four-Way Reversing Valve

64 66 Electronic Expansion Valve. 68 Q Series. 70 S Series T Series O Series R Series Four-Way Reversing Valve Catalog bout Sanhua Solutions HVC&R Components 0 04 Thermal Expansion Valve Series Series 64 66 Electronic Expansion Valve C Series Q Series 06 Series 70 S Series T Series O Series R Series 09 8 Filter

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and

More information

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter) PSC9713 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression

More information

Quality Heat Exchangers

Quality Heat Exchangers Quality Heat Exchangers Brazed Plate Heat Exchangers Universal solutions for industrial and domestic applications With partnership into the future FUNKE is a leader in the development and production of

More information

RA 2000 Series RA 15/6T & TB Conversion Valve

RA 2000 Series RA 15/6T & TB Conversion Valve RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water

More information

Sporlan Valve Division Parker Hannifan/CIC Group

Sporlan Valve Division Parker Hannifan/CIC Group www.parker.com/cic Sporlan Valve Division Parker Hannifan/CIC Group Matt McGrath, SW Regional Sales Manager Bob Dolan, Sales Engineer - Atlanta www.parker.com/cic Why Discuss TEVs Today? Expansion Valves

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

13-1. Temperature Regulator

13-1. Temperature Regulator -1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details

More information

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications Series P77 Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications Product bulletin These pressure controls are designed for use in a variety of applications involving refrigeration

More information

AlfaNova the first fusion-bonded plate heat exchanger. A product brochure for AlfaNova within Industrial Refrigeration

AlfaNova the first fusion-bonded plate heat exchanger. A product brochure for AlfaNova within Industrial Refrigeration AlfaNova the first fusion-bonded plate heat exchanger A product brochure for AlfaNova within Industrial Refrigeration AlfaNova A new concept for plate heat exchangers Out of the extreme heat in our furnaces

More information

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit FSW Product guide E SECTION Thermostats, Pressure Switches & Fan Speed Controls. 63 64 Head Office 01543 437 010 Danfoss Service Thermostat Kits TYPE TO SUIT E005 NO-1 Refrigerator E006 NO-2 Refrigerator

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Thermostatic Control Valves

Thermostatic Control Valves Thermostatic ontrol Valves Model Typical applications Lubricating oil temperature control Jacket temperature (HT) Secondary water low temperature (LT) Heat recovery Water saving applications oiler inlet

More information

SECTION REFRIGERANT PIPING

SECTION REFRIGERANT PIPING SECTION 23783 REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

PTG series valves 0490EN June 2018 Valves with thermostatic option for radiators, with presetting

PTG series valves 0490EN June 2018 Valves with thermostatic option for radiators, with presetting PT series valves 090E une 08 R0PT R0PT RPT RPT R0PT RPT escription The PT valves with thermostatic option and presetting are used to slice the delivery water flow rate in a radiator. hen the special worksite

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer E/F Series For use in Europe, sia and Oceania Standard/ E Series H HW Power supply voltage: Single-phase 230 V (50Hz) 3E 4E 6E 8E 11E 15E1 22E 37E 55E 75E ir flow capacity (m3/h [NR])

More information

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION DOMESTIC WATER PIPING SPECIALTIES SECTION 22 11 19 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82 ASTM A 216 WBC.

DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA TRIM DESCRIPTION DESCRIPTION VALVE OPERATION. 82  ASTM A 216 WBC. DELUGE VALVE MODEL: SD-DVH2 TECHNICAL DATA NORMAL SIZE MATERIAL SEVICE PRESSURE THREADED OPENING MOUNTING FACTORY HYDOSTATIC TEST PRESSURE FLANGE CONNECTION WET PILOT SPRINKLER HEIGHT LIMITATION NET WEIGHT

More information

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133. Main Steam How to Select Steam For Steam Vent selection information, please refer to Selection Guidelines on page 133. Model Radiator Convector Unit Thermostatlic Number (Angle Type) (Bottom Inlet) Heater

More information

Function. Pressure Vessel Inspector; CRN registered Sizes 2 4

Function. Pressure Vessel Inspector; CRN registered Sizes 2 4 ISLIRT air and dirt separator series and N RISTR SI N ISO 900:000 ert. n M UNI N ISO 900:000 ert. n 000 LI 0/. N Replaces 0/ N unction ir and dirt separators are used to continuously remove the air and

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ,1,_2008 Lennox Industries Inc, Dallas, Texas, USA INSTALLATION INSTRUCTIONS CR33 Series Coils EVAPORATOR COILS _ Technical 505,056M LL.L[ Publications 04108 Litho U.S.A. Supersedes 05/05 CR33 Series Coils...

More information

THE THERMOSTATIC STEAM TRAP

THE THERMOSTATIC STEAM TRAP THE THERMOSTATIC STEAM TRAP The purpose of any steam trap is to discharge, promptly, all condensate (as well as air and other non-condensible gases) without discharging live steam. Since steam is a vapor

More information

Water Piping and Pumps

Water Piping and Pumps Technical Development Program DISTRIBUTION SYSTEMS Water Piping and Pumps PRESENTED BY: Michael Ho carriertdp@gmail.com 424-262-2144 Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section

More information

Radiator Trap Radiator Valve

Radiator Trap Radiator Valve Radiator Trap Radiator Valve -1 Step 0 Type/Structure/Features Please refer to this for structure and features of Radiator Trap, Radiator Valve, and Cold & Hot Water Valve. Oventrop GmbH & Co. KG For products

More information

PLEXUS. Marine HVAC Components for Boats and Yachts CATALOGUE

PLEXUS. Marine HVAC Components for Boats and Yachts CATALOGUE PLEXUS Marine HVAC Components for Boats and Yachts CATALOGUE 08/2017 1 PLEXUS CATALOGUE 08/2017 Self Contained ASC MAP Series...2 Split ASP System ASP Series... 4 Water Chiller AWC Series - Single Chiller...

More information

M7100 Pressure Transducer

M7100 Pressure Transducer SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces

More information

PF Series. Piston Actuated Valves

PF Series. Piston Actuated Valves PF Series Piston Actuated Valves PF Series Piston actuated valves About The PF Series The Spirax Sarco PF Range of Piston Actuated Valves (PAVs) provides a competitive solution for on/off applications

More information

ProRadiant Controls, Valves and Actuators

ProRadiant Controls, Valves and Actuators 214 Controls, Valves and Actuators Stock Controls, Valves and Actuators BASIC HEATING CONTROL Features: Modulating mixing valve control Supply temperature high limit Seasonal pump activation Boiler activation

More information

BALANCED PORT Q-VALVE

BALANCED PORT Q-VALVE March 2001 / BULLETIN 10-10-6 ELEMENT BALANED PORT Q-VALVE ARTRIDGE BODY Page 2 / BULLETIN 10-10-6 Introducing the Balanced Port -Valve The BQ combines the flexibility of the replaceable cartridge style

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH

INSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH TXV Horizontal Slab Coils WLSH These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

Sealed Type Liquid Line and Suction Line Specifications

Sealed Type Liquid Line and Suction Line Specifications CATALOG 0 Page,, 4a, 404A, 407C, 40A, 0, 07 Also Compatible with Refrigerants, 4,, 40A & B, 40A & B, 408A, 409A The universal acceptance of the Catch-All Filter-Drier is due to its unique molded porous

More information

Owner s Manual Therma-Stor II Heat Recovery System

Owner s Manual Therma-Stor II Heat Recovery System PO Box 8680 Madison, WI 53708 TS-138C Revised 8/08 Owner s Manual Therma-Stor II Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents 1.

More information

Flameless Electric Air Heaters: Heater Style Application & Selection Guide

Flameless Electric Air Heaters: Heater Style Application & Selection Guide High Temperature Air Heater Flameless Electric Air Heaters: Heater Style Application & Selection Guide Repeatable Adaptable Stable Reliable Precise Accurate ontrollable lean Sturdy Responsive Economical

More information

y Small dimensions. Easy to install in refrigerated counters or cold rooms

y Small dimensions. Easy to install in refrigerated counters or cold rooms MAKING MODERN LIVING POSSIBLE Data sheet Thermostat Type KP The KP Thermostats are temperaturecontrolled electrical switches. All KP Thermostats have a single pole double throw (SPDT) changeover switch.

More information

Heating Controls Thermostatic and Manual Radiator Valve range

Heating Controls Thermostatic and Manual Radiator Valve range Heating ontrols Thermostatic and Manual Radiator Valve range Heating ontrols New thermostatic and manual radiator valves with built-in energy saving solutions With increasing demands on specifiers and

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ,t_2007 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR 505,264M (65484504) 10/07 Supersedes 09/06 COILS n _putech blications ical Litho U.S.A. RETAIN THESE

More information

Circulation Heaters - EX

Circulation Heaters - EX pplication irculation Heaters - RMOVL LN HTR SKT aloritech circulation heaters are suitable for use in forced flow and natural flow heating loops where a safe, lean, reliable, and efficient heating source

More information

DESIGN STANDARDS SECTION 15600

DESIGN STANDARDS SECTION 15600 PART 1 - GENERAL 1.1 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.2 General requirements: A. Reciprocating

More information

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers GUIDE SPECIFICATIONS WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers WW024-072 Reverse Cycle Chillers / Low Temperature Boilers GENERAL Units shall be Underwriter Laboratories (UL) listed

More information

Temperature controller for steam (PN 25) AVT / VGS - external thread

Temperature controller for steam (PN 25) AVT / VGS - external thread Data sheet Temperature controller for steam (PN 25) AVT / VGS - external thread Description The controller has a control valve VGS, thermostatic actuator and handle for temperature setting. Thermostatic

More information

Series F61. Liquid Flow Switches. Feature and Benefits. T-body and Pipe-insert types available

Series F61. Liquid Flow Switches. Feature and Benefits. T-body and Pipe-insert types available PSC9720 European Refrigeration Controls Catalogue Catalog Section 3 Product Bulletin F61 Series F61 Liquid Flow Switches I ntroduction The F61 liquid flow switches can be used in liquid lines carrying

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE October 10, 2008 Deluge Devices 281a 1. PRODUCT DESCRIPTION The Viking Model C-1 is a rate-of-rise releasing device for use on hydraulic and pneumatic release systems controlling operation of Viking deluge

More information

EC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons

EC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons E & Split Systems Water Source Heat Pump 6 to 30 tons The E, including Split Systems, provides the best combination of performance, comfort and one-of-a-kind features that satisfy the high demands of any

More information

pyxis pyxisa NEW rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning

More information

water to water heat pumps

water to water heat pumps AQUARIUS WW SERIES water to water heat pumps O ur Aquarius WW Series water-cooled modular reverse cycle chillers are designed to meet all your replacement or new construction chiller requirements. Specifically

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Connection set. Radiator connection set for thermostatic and manual operation Ø 12 Connection set Radiator connection set for thermostatic and manual operation Data sheet for 1 7650 00 Issue 0405 Control valves Connection pipe Ø 12 L L = 600 1 7650 00 L = 1000 1 7650 01 Bypass bodies

More information

PureFlow. PureFlow. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 61 Annex G Standards.

PureFlow. PureFlow. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 61 Annex G Standards. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 1 Annex G Standards. 11 PEX Manifold Plumbing Systems # of Outlets: Dimension (hot,cold) MANABLOC -BRONZE PEX PRESS

More information

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system

More information

Air-Cooled Condenser. Installation Instructions. Revision Date: 12/21/98

Air-Cooled Condenser. Installation Instructions. Revision Date: 12/21/98 Air-Cooled Condenser Installation Instructions Revision Date: 12/21/98 ! WARNING! These installation guidelines must be followed to obtain reliable operation from air-cooled ice machines. If these guidelines

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers /IU Series Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic

More information

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc) onvertible radiator valve for one-pipe and two-pipe systems series ARIT 0/ G ISO 0 M ISO 0 No. 000 unction The series convertible radiator valve can be used both on one-pipe and two-pipe radiator systems.

More information

COMPANY PROFILE. F ounded in 1970, Kaori's goal is the pursuit of modernization of heat-treating

COMPANY PROFILE. F ounded in 1970, Kaori's goal is the pursuit of modernization of heat-treating COMPANY PROFILE F ounded in 197, Kaori's goal is the pursuit of modernization of heat-treating technology. Our staff has made every effort to improve on hardware and software, research & development, and

More information

Dual Pressure Controls

Dual Pressure Controls PRESSURE CONTROLS Dual Pressure Reset Hp/Lp Range Differential kpa kpa Ranco Dual Pressure G0048 017-8711* -30 to 700 700 to 3000 62 to 393 350 bar fixed G0056 017-8701 -30 to 700 700 to 3000 62 to 393

More information

RA2000 Thermostatic Radiator Valves

RA2000 Thermostatic Radiator Valves Data Sheet RA2000 Thermostatic Radiator Valves Application regulate the flow of hot water or steam through free-standing radiators, baseboards or convectors in hot water and two-pipe low pressure steam

More information

Instruction Manual. Crescent Cuber Models WME-2500SRH. hoshizakiamerica.com

Instruction Manual. Crescent Cuber Models WME-2500SRH. hoshizakiamerica.com Instruction Manual Crescent Cuber Models WME-2500SRH hoshizakiamerica.com Issued: 10-7-2009 Revised: 8-10-2017 IMPORTANT Only qualified service technicians should install, service, or maintain this icemaker.

More information

Brazed Plate Heat Exchanger

Brazed Plate Heat Exchanger Brazed Plate Heat Exchanger Certificate.UL.ISO9001:2008.CE/PED.JAPAN KHK Patent.High Pressure Brazed Plate Heat Exchanger Patents in Taiwan, China, Japan and Germany.Air Dryer Brazed Plate Heat Exchanger

More information

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions 4201 Lien Rd Madison, WI 53704 TS-140F Revised 09-10 Owner s Manual Therma-Stor III Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents

More information

Thermostatic Radiator Valves (Caleffi)

Thermostatic Radiator Valves (Caleffi) 02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled

More information

Hoshizaki America, Inc.

Hoshizaki America, Inc. Hoshizaki America, Inc. Modular Crescent Cuber Models KM-901MAH50 KM-901MRH50 A Superior Degree of Reliability INSTRUCTION MANUAL www.hoshizaki.com Issued: 6-21-2010 IMPORTANT Only qualified service technicians

More information

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning Industrial PYXIS CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with scroll compressor and microchannel condensing coils Cooling Capacity: 108 876

More information

MAKING MODERN LIVING POSSIBLE. One valve for all purposes. TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION

MAKING MODERN LIVING POSSIBLE. One valve for all purposes. TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION MAKING MODERN LIVING POSSIBLE One valve for all purposes TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION TGE: reliable, environmentally -friendly and easy to use Danfoss Refrigeration

More information

TECHNICAL DATA. model c-2

TECHNICAL DATA. model c-2 Page 1 of 6 1. PRODUCT DESCRIPTION The Viking Model C-2 is a rate-of-rise releasing device for use on hydraulic and pneumatic release systems controlling operation of Viking deluge valves on deluge or

More information

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT

More information

Product catalogue 2012/13. Electromechanical controllers

Product catalogue 2012/13. Electromechanical controllers Product catalogue 2012/13 Electromechanical controllers Electromechanical controllers Contents The controllers and components included in this catalogue, well-known on the market for their reliability

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

General information on refrigerant controllers

General information on refrigerant controllers General information on refrigerant controllers Condensing pressure controller The condensing or condenser pressure controller is a back pressure controller and its task is to maintain the condensing pressure

More information

P2050B005, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

P2050B005, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends P2050005, 1/2, Pressure Independent Valve hrome Plated rass all and rass Stem, NPT emale nds pplication The Pressure Independent haracterized ontrol Valve is typically used in air handling units on heating

More information

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA TankMixer water heater tank mixing valve 520 series CLEFFI 01267/17 N CCREDITED ISO 9001 FM 21654 ISO 9001 No. 000 Function The Caleffi TankMixer 520_X series kit combines a three-way thermostatic mixing

More information

SECTION AIR COILS

SECTION AIR COILS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 23 82 16 AIR COILS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in the section

More information

Technical Specification

Technical Specification Technical Specification 3 Series Pulse Jet Valves FS3 Series T3 Series DD3 Series Description Superior performance, easy maintenance diaphragm valve available with threaded ports (T3), dresser nut ports

More information

Three-way reversing valve

Three-way reversing valve Three-way reversing valve For heating and cooling systems Pressurisation & Water Quality Balancing & Control thermostatic Control engineering avantage Three-way reversing valve for the distribution of

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Series Units RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING Improper installation, adjustment, alteration, service or maintenance can cause personal injury, loss of life,

More information

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION.   71 FSW Product guide F SECTION Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches For more information visit www.fsw.uk.com 71 Danfoss Expansion Valves T* Range - Order valve and orifice

More information

Flow Control for Fire Protection

Flow Control for Fire Protection Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality

More information

Series 1140 and 1141 Temperature Regulators

Series 1140 and 1141 Temperature Regulators Hoffman Specialty Installation & Maintenance Instructions HS-504(E) Series 1140 and 1141 Temperature Regulators! CAUTION FOLLOW ALL INSTALLATION AND OPERATING INSTRUCTIONS. TURN OFF WATER OR STEAM BEFORE

More information

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE Application Thermostatic flowshare valves control the output of radiators in vertical one-pipe heating systems. Heating water not required

More information

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE

TECHNICAL DATA DELUGE SYSTEM CONTROLLED BY ELECTRIC RELEASE Page 1 of 8 1. DESCRIPTION Viking Deluge Systems utilize a Viking Deluge Valve to control the water supply to system piping equipped with open sprinklers and/or spray nozzles. The system piping remains

More information

Brazed Plate Heat Exchanger

Brazed Plate Heat Exchanger Brazed Plate Heat Exchanger Certificate.UL.ISO9001:2008.CE/PED.JAPAN KHK Patent.High Pressure Brazed Plate Heat Exchanger Patents in Taiwan, China, Japan and Germany.Air Dryer Brazed Plate Heat Exchanger

More information

97105 Namur direct pneumatically actuated 3/2 and 5/2 spool valves

97105 Namur direct pneumatically actuated 3/2 and 5/2 spool valves direct pneumatically actuated / and / spool valves flanged with NAMUR Interface For single and double operated actuators Valves for safety systems up to SIL (IEC 108) Crossover-free switching, switch-over

More information

SB Series Brazed Plate Heat Exchanger Installation Manual

SB Series Brazed Plate Heat Exchanger Installation Manual SB Series Brazed Plate Heat Exchanger Installation Manual HOT COLD Exploded view of Schmidt SB Brazed Plate Heat Exchanger. WARNING Before proceeding with installation and operation read entire manual

More information

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation Standard C Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard C Standard C The Standard C thermostatic

More information