V46. Pressure actuated water valves. Refrigeration components Modulating water valves. Catalogue page

Size: px
Start display at page:

Download "V46. Pressure actuated water valves. Refrigeration components Modulating water valves. Catalogue page"

Transcription

1 2-way pressure actuated water valves - ommercial applications These pressure actuated modulating valves control the quantity of water to a condenser by directly sensing pressure changes in a refrigerant circuit. The valves can be used in non-corrosive refrigerant systems. mmonia power elements and valves designed for salt-water applications are available. The valves have a quick opening characteristic and open on pressure increase (direct acting). Reverse acting (close on pressure increase) is possible. eatures ffpressure balanced valve design ffpressure actuated ff3/8, 1/2, 3/4 are angled body type valves with high Kv value ff3/8 up to 2 pressure valves all range types ffquick opening valve characteristics ffno close fitting or sliding parts in water passages ffasy to disassemble. ll parts can be replaced ffspecial bronze bodies and monel parts ffpower elements with stainless steel bellows available ffwide range of pressure connection s ffnickel plated seats available for 3/8, 1/2, and 3/4 valves ffirect/reverse action imensions in mm Valve size 3/ / / a (excl. valve depressor) 1: cm capillary 2: 7/16-20 UN flare nut 34 1: cm capillary 2: 1/4 tube for braze connection (incl. valve depressor mounted into machined flare) 1: cm capillary 2: 7/16-20 UN flare nut 3: copper sealring 15 1/4-18NPT (female) 5 7/16-20 UN

2 ngled Size thread according to ISO 228 apillary (cm) dditional features It is possible to change into /8 100 Nickel plated seat/longer capillary With special washer to prevent waterhammer at low flow capacity Nickel plated seat/solder connection.040 i.d.cap./solder connection / Solder connection/ 062 id.cap / Solder connection ngled 3/8 Nickel plated seat, high range. With washer to prevent waterhammer at low flow capacity Nickel plated seat, high range Nickel plated seat, high range. With washer to prevent waterhammer at low flow capacity 9510 High range /2 Nickel plated seat, high range Solder connection, high range High range /4 Nickel plated seat, high range High range

3 imension in mm Valve size ¼ Size thread according to ISO 7-Rc apillary ¼ ¼ dditional features It is possible to change into 45 High range

4 G H J I imensions in mm Valve size G H I J 1½ ½ Size IN2533 flang connections apillary R ½ R-9600 S-9300 S T-9300 T ½ 18 dditional features It is possible to change into 45

5 imension in mm Valve size 3/ / / ¼ Size thread according to ISO 228 3/ / / ¼ /8 apillary dditional features It is possible to change into / / Longer capillary ¼ 1 Longer capillary

6 G H J I imensions in mm Valve size G H I J 1½ ½ Size IN flange connections R ½ R-9600 S-9300 S T-9300 T ½ apillary 18

V46 2-way Pressure Actuated Water Valves - Commercial Applications

V46 2-way Pressure Actuated Water Valves - Commercial Applications Pressure ctuated Water Valves V46 2-way Pressure ctuated Water Valves - ommercial pplications These pressure actuated modulating valves control the quantity of water to a condenser by directly sensing

More information

Opening Point Adjustment Range psig (kpa) Commercial Type Non-Corrosive RefrigerantsS (R) 160 to 260 (1103 to 1793) 70 to 150 (483 to 1034)

Opening Point Adjustment Range psig (kpa) Commercial Type Non-Corrosive RefrigerantsS (R) 160 to 260 (1103 to 1793) 70 to 150 (483 to 1034) Repair Parts V43 Series Description The V43 is a pilot pressure actuated modulating valve for use on water cooled condensers that require a large flow capacity. Valves open on pilot pressure increase.

More information

13-1. Temperature Regulator

13-1. Temperature Regulator -1 Step 0 Type/Structure/Features Please refer to this for type, structure and features of. Step 1 Selection Please look at the ID chart to choose the right products depending on the intended uses. Details

More information

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter) PSC9713 European Refrigeration Controls Catalogue Catalog Section 4 Product Bulletin Series Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression

More information

V246 Series Two-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

V246 Series Two-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants V246 Series Two-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants Description The V246 Series Two-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

More information

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

SOLENOID VALVES FOR REFRIGERATING SYSTEMS SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97/23/EC, Article

More information

ProRadiant Controls, Valves and Actuators

ProRadiant Controls, Valves and Actuators 214 Controls, Valves and Actuators Stock Controls, Valves and Actuators BASIC HEATING CONTROL Features: Modulating mixing valve control Supply temperature high limit Seasonal pump activation Boiler activation

More information

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant

More information

Radiator Valve Program

Radiator Valve Program Radiator Valve Program Heat seeks cold faster when the temperature difference is greater. Lowering the temperature of a room reduces the amount of heat leaving the room (heat loss). Installing thermostats

More information

Three-way reversing valve

Three-way reversing valve Three-way reversing valve For heating and cooling systems Pressurisation & Water Quality Balancing & Control thermostatic Control engineering avantage Three-way reversing valve for the distribution of

More information

V2, V4 and V8 Thermostats Self-acting Temperature Controls I GB-1. Characteristics. Applications. Function. Design

V2, V4 and V8 Thermostats Self-acting Temperature Controls I GB-1. Characteristics. Applications. Function. Design GB-1 Characteristics Closing force 200 N, 400 N and 800 N For heating or cooling valves Sturdy and reliable Temperature range 0 to 160ºC (-30 to 280ºC on request) Applications The temperature controller,

More information

SECTION REFRIGERANT PIPING

SECTION REFRIGERANT PIPING SECTION 23783 REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

PF Series. Piston Actuated Valves

PF Series. Piston Actuated Valves PF Series Piston Actuated Valves PF Series Piston actuated valves About The PF Series The Spirax Sarco PF Range of Piston Actuated Valves (PAVs) provides a competitive solution for on/off applications

More information

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation Standard C Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard C Standard C The Standard C thermostatic

More information

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Catalog. Self-operated Regulators Volume 2 Temperature Regulators Catalog Self-operated Regulators Volume 2 Temperature Regulators Self-operated Regulators Temperature Regulators Volume 2 Catalog 2012 Overview Self-operated Temperature Regulators 5 Self-operated Pressure

More information

THE THERMOSTATIC STEAM TRAP

THE THERMOSTATIC STEAM TRAP THE THERMOSTATIC STEAM TRAP The purpose of any steam trap is to discharge, promptly, all condensate (as well as air and other non-condensible gases) without discharging live steam. Since steam is a vapor

More information

RA 2000 Series RA 15/6T & TB Conversion Valve

RA 2000 Series RA 15/6T & TB Conversion Valve RA 2000 Series RA 15/6T & TB Conversion Valve Applications: RA15/6T Internal bypass allowing for series piping to the radiators/baseboards. This series piping provides continuous flow but the supply water

More information

Sealed Type Liquid Line and Suction Line Specifications

Sealed Type Liquid Line and Suction Line Specifications CATALOG 0 Page,, 4a, 404A, 407C, 40A, 0, 07 Also Compatible with Refrigerants, 4,, 40A & B, 40A & B, 408A, 409A The universal acceptance of the Catch-All Filter-Drier is due to its unique molded porous

More information

Radiator Trap Radiator Valve

Radiator Trap Radiator Valve Radiator Trap Radiator Valve -1 Step 0 Type/Structure/Features Please refer to this for structure and features of Radiator Trap, Radiator Valve, and Cold & Hot Water Valve. Oventrop GmbH & Co. KG For products

More information

RA15/6T & TB Conversion Valve

RA15/6T & TB Conversion Valve Applications: continue on. This provides continuous flow, but inherent to series piping the supply water temperature will decrease as it flows through the system and when it mixes with return water from

More information

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C)

INDEX. Air flow capacity SCFM (m 3 /h [ANR]) Model Outlet air pressure dew point Note) 37 F (2.8 C) 45 F (7.2 C) 50 F (10 C) Refrigerated ir ryer Series IF For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor,

More information

y Small dimensions. Easy to install in refrigerated counters or cold rooms

y Small dimensions. Easy to install in refrigerated counters or cold rooms MAKING MODERN LIVING POSSIBLE Data sheet Thermostat Type KP The KP Thermostats are temperaturecontrolled electrical switches. All KP Thermostats have a single pole double throw (SPDT) changeover switch.

More information

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler UL Quick Response FM Standard Response ½ (13mm) Cover plate Adjustment Features 1. Flat cover plate with threaded attachment. 2. Solid or perforated cover plate available in chrome and white as Standard

More information

Quality Heat Exchangers

Quality Heat Exchangers Quality Heat Exchangers Brazed Plate Heat Exchangers Universal solutions for industrial and domestic applications With partnership into the future FUNKE is a leader in the development and production of

More information

Dynamic thermostatic radiator valves DYNAMICAL

Dynamic thermostatic radiator valves DYNAMICAL ynamic thermostatic radiator valves YNMIL -----7 series RIT ISO 9 M 6 /7 G unction The YNMIL valve allows the automatic dynamic balancing and pressure-independent adjustment of the thermal medium in the

More information

Temperature controller for steam (PN 25) AVT / VGS - external thread

Temperature controller for steam (PN 25) AVT / VGS - external thread Data sheet Temperature controller for steam (PN 25) AVT / VGS - external thread Description The controller has a control valve VGS, thermostatic actuator and handle for temperature setting. Thermostatic

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE October 10, 2008 Deluge Devices 281a 1. PRODUCT DESCRIPTION The Viking Model C-1 is a rate-of-rise releasing device for use on hydraulic and pneumatic release systems controlling operation of Viking deluge

More information

Thermostatic Radiator Valves (Caleffi)

Thermostatic Radiator Valves (Caleffi) 02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled

More information

TA-Compact-P. Giving you MORE by giving you LESS

TA-Compact-P. Giving you MORE by giving you LESS TA-Compact-P Giving you MORE by giving you LESS control valve balancing valve 5 in 1 full measurement TA-Compact-P The new two-way pressure independent balancing and control valve for terminal units in

More information

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION DOMESTIC WATER PIPING SPECIALTIES SECTION 22 11 19 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

STRAIGHT AND ANGLED THERMOSTATIC VALVES

STRAIGHT AND ANGLED THERMOSTATIC VALVES ST.07.01.00 STRIGHT ND NGLED THERMOSTTIC VLVES 1. DESCRIPTION FR thermostatic valves are preset for assembly of thermostatic and thermo-electric actuators, which control opening and closure. rt. 16 Chrome-plated

More information

Pressure switch KPU. Data sheet

Pressure switch KPU. Data sheet Data sheet Pressure switch KPU The KPU switches are designed for use in refrigeration and air-conditioning systems to protect the systems from excessively low suction or too high discharge. They can also

More information

TECHNICAL DATA. model c-2

TECHNICAL DATA. model c-2 Page 1 of 6 1. PRODUCT DESCRIPTION The Viking Model C-2 is a rate-of-rise releasing device for use on hydraulic and pneumatic release systems controlling operation of Viking deluge valves on deluge or

More information

Quality Heat Exchangers

Quality Heat Exchangers Quality Heat Exchangers Brazed Plate Heat Exchangers Universal solutions for industrial and domestic applications With partnership into the future FUNKE is a leader in the development and production of

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 The XB is a brazed plate heat exchanger designed for use with district heating systems (i.e. air conditioning,

More information

Disc Type Steam Trap TSD-42

Disc Type Steam Trap TSD-42 Disc Type TSD-42 TSD-42 is disc type steam trap for high pressure (maximum pressure: 4.2 MPa). It is compact and lightweight, and can be installed horizontally or vertically. Disc Ring By-Metal Valve seat

More information

PTG series valves 0490EN June 2018 Valves with thermostatic option for radiators, with presetting

PTG series valves 0490EN June 2018 Valves with thermostatic option for radiators, with presetting PT series valves 090E une 08 R0PT R0PT RPT RPT R0PT RPT escription The PT valves with thermostatic option and presetting are used to slice the delivery water flow rate in a radiator. hen the special worksite

More information

Series F61. Liquid Flow Switches. Feature and Benefits. T-body and Pipe-insert types available

Series F61. Liquid Flow Switches. Feature and Benefits. T-body and Pipe-insert types available PSC9720 European Refrigeration Controls Catalogue Catalog Section 3 Product Bulletin F61 Series F61 Liquid Flow Switches I ntroduction The F61 liquid flow switches can be used in liquid lines carrying

More information

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications Series P77 Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications Product bulletin These pressure controls are designed for use in a variety of applications involving refrigeration

More information

M7100 Pressure Transducer

M7100 Pressure Transducer SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces

More information

PureFlow. PureFlow. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 61 Annex G Standards.

PureFlow. PureFlow. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 61 Annex G Standards. Fittings system This section doesn t meet California AB1953, Vermont ACT 193 and NSF 1 Annex G Standards. 11 PEX Manifold Plumbing Systems # of Outlets: Dimension (hot,cold) MANABLOC -BRONZE PEX PRESS

More information

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Data sheet Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25) Description STW871 The controllers are: - Type-tested acc. to EN 14597 and protect against exceeding temperatures:

More information

THERMODYNAMIC STEAM TRAP

THERMODYNAMIC STEAM TRAP THERMODYNAMIC STEAM TRAP Model 041 Model 043 041 043 For the extraction of steam condensates. For use in: steam piping, irons, laundries, tanks and vessels with condensate discharge, multiple plate presses,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ,t_2007 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS CH33 Series Units EVAPORATOR 505,264M (65484504) 10/07 Supersedes 09/06 COILS n _putech blications ical Litho U.S.A. RETAIN THESE

More information

Dehydrators and Filters

Dehydrators and Filters Dehydrators and Filters DEHYDRATION OF REFRIGERANTS Among contaminating agents causing serious damages to refrigerating systems, moisture plays a major role. Its presence, even possible in the refrigerating

More information

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Pipe and Pipe Fittings. B. Air compressor. C. Air receiver and accessories. D. Aftercooler. E. Refrigerated air dryer. F. Pressure reducing station. 1.02 RELATED

More information

pyxis u pyxis ua NEW rcgroupairconditioning

pyxis u pyxis ua NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44,9 200,0 rcgroupairconditioning R410 C PLTE

More information

VALVES SECTION 15100

VALVES SECTION 15100 VALVES SECTION 15100 PART 1 GENERAL 1.1 DESCRIPTION A. The requirements of this SECTION apply to all Work of this DIVISION where applicable. The valves, materials, and methods herein are generally common

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

Brazed Plate Heat Exchanger

Brazed Plate Heat Exchanger Brazed Plate Heat Exchanger Certificate.UL.ISO9001:2008.CE/PED.JAPAN KHK Patent.High Pressure Brazed Plate Heat Exchanger Patents in Taiwan, China, Japan and Germany.Air Dryer Brazed Plate Heat Exchanger

More information

Control valves for floor heating systems. Floor Heating Manifolds

Control valves for floor heating systems. Floor Heating Manifolds Control valves for floor heating systems Floor Heating Manifolds IMI HEIMEIER / Floor Heating Control / Control valves for floor heating systems Control valves for floor heating systems Supply control

More information

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT Technical Data SD 4511A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE T14 & T14D TEMPERATURE PILOT PRINTED IN U.S.A. SD 4511A/9811 5 13 /16 D 4 7 /8 1 13 /16 T14 PILOT

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and

More information

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION.   71 FSW Product guide F SECTION Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches For more information visit www.fsw.uk.com 71 Danfoss Expansion Valves T* Range - Order valve and orifice

More information

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA TankMixer water heater tank mixing valve 520 series CLEFFI 01267/17 N CCREDITED ISO 9001 FM 21654 ISO 9001 No. 000 Function The Caleffi TankMixer 520_X series kit combines a three-way thermostatic mixing

More information

Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits

Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits Manufacturer of Medical Gas Pipeline Equipment Installation Instructions for Med-Touch Series LCD Medical Gas Area, Master & Combination Alarms Conversion Kits Master Alarm Conversion Combination Alarm

More information

Installation Instructions

Installation Instructions IMPORTANT Installation and final temperature adjustment are the responsibility of the installer. Installation Instructions Thermostatic Mixing Valve for Sinks/Faucets Inlet Outlet Model Connection Connection

More information

610 AC3 CONTROL KNOB (OFF, PILOT, ON) TEMPERATURE SELECTION KNOB ON-OFF REGULATING THERMOSTAT THERMOELECTRIC SAFETY DEVICE.

610 AC3 CONTROL KNOB (OFF, PILOT, ON) TEMPERATURE SELECTION KNOB ON-OFF REGULATING THERMOSTAT THERMOELECTRIC SAFETY DEVICE. SIT Group 610 AC3 MULTIFUNCTIONAL GAS CONTROL CONTROL KNOB (OFF, PILOT, ON) TEMPERATURE SELECTION KNOB ON-OFF REGULATING THERMOSTAT THERMOELECTRIC SAFETY DEVICE PIN 0085AO0252 THERMOSTATIC MULTIFUNCTIONAL

More information

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design Fire Protection Div. Dorot Fire Protection Division Deluge Valves Model 68 DE\ EL Electrically Actuated Remote-Reset Deluge Valve Certification & compliance by design 1 ANSI FCI 70-2 Class VI seat leakage

More information

Flow Control for Fire Protection

Flow Control for Fire Protection Flow Control for Fire Protection Valve Solutions From An Industry Leader AmesFireWater.com Count on the Fire Protection Leader for Reliable Flow Control Solutions Ames provides a range of high-quality

More information

Flexible. Upgrade and service with ease Extend lifetime with modular design. Thermostatic expansion valves Type TE5-55

Flexible. Upgrade and service with ease Extend lifetime with modular design.   Thermostatic expansion valves Type TE5-55 MAKING MODERN LIVING POSSIBLE Upgrade and service with ease Extend lifetime with modular design Thermostatic expansion valves Type TE5-55 Flexible Upgrade with backward compatible valve technology. Mix

More information

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services TA-COMFORT-S Prefabricated units Heating interface unit for surface heating and hot water services IMI TA / Prefabricated units / TA-COMFORT-S TA-COMFORT-S All in one design with differential pressure

More information

I ntroduction. Series F61. Liquid Flow Switches. Feature and Benefits

I ntroduction. Series F61. Liquid Flow Switches. Feature and Benefits PSC9720 European Refrigeration Controls Catalogue Catalog Section 3 Product Bulletin F61 Series F61 Liquid Flow Switches I ntroduction The F61 liquid flow switches can be used in liquid lines carrying

More information

pyxis pyxisa NEW rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning

More information

Systems for central heating

Systems for central heating www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering

More information

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Connection set. Radiator connection set for thermostatic and manual operation Ø 12 Connection set Radiator connection set for thermostatic and manual operation Data sheet for 1 7650 00 Issue 0405 Control valves Connection pipe Ø 12 L L = 600 1 7650 00 L = 1000 1 7650 01 Bypass bodies

More information

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation Standard Sheet for 6823/ 6824 Edition 1000 (0999) 6823 6824 Special Models 1

More information

Thermostatic expansion valves for ammonia Type TEA

Thermostatic expansion valves for ammonia Type TEA Data sheet Thermostatic expansion valves for ammonia Type TEA Thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. Injection is controlled by the refrigerant superheat.

More information

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold Dynalux Floor Heating Manifolds Underfl oor heating circuit manifold IMI HEIMEIER / Floor Heating Control / Dynalux Dynalux Dynalux adjusts the flow rate in the individual heating circuits directly in

More information

Brazed Plate Heat Exchanger

Brazed Plate Heat Exchanger Brazed Plate Heat Exchanger Certificate.UL.ISO9001:2008.CE/PED.JAPAN KHK Patent.High Pressure Brazed Plate Heat Exchanger Patents in Taiwan, China, Japan and Germany.Air Dryer Brazed Plate Heat Exchanger

More information

LIQUIDATOR 450 SERIES

LIQUIDATOR 450 SERIES LIQUIDATOR 450 UMT SERIES TRAP AND UMTC CONNECTOR APPLICATIONS Unit Heaters Steam Tracing Drip Legs Tire Presses Cooking Equipment Laundry Equipment Plating Tanks Platen Presses Air Vents OPTIONS SLR -

More information

Thermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment

Thermo-Platens. Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment Cast-In Aluminum and Bronze Platen Die Heaters for Plastics Processing Equipment Cast-In Platen Heaters are widely accepted as the industry standard for heating critical, temperaturesensitive plastics

More information

V246 Series 2-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

V246 Series 2-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants Code No. LIT-1900575 Issued June 19, 2009 V246 Series 2-Way ressure-actuated Water-Regulating Valves for High-ressure Refrigerants Description The V246 Series 2-Way ressure-actuated Water-Regulating Valves

More information

Technical Specification

Technical Specification Technical Specification 3 Series Pulse Jet Valves FS3 Series T3 Series DD3 Series Description Superior performance, easy maintenance diaphragm valve available with threaded ports (T3), dresser nut ports

More information

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning Industrial PYXIS CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with scroll compressor and microchannel condensing coils Cooling Capacity: 108 876

More information

Fuel Manager Diesel Fuel Filtration. FM1, FM10, FM100 and FM1000 Complete Systems, Elements and Service Parts

Fuel Manager Diesel Fuel Filtration. FM1, FM10, FM100 and FM1000 Complete Systems, Elements and Service Parts uel Manager Diesel uel iltration M1, M10, M100 and M1000 Complete Systems, s and Service Parts uel Manager diesel fuel filter/water separator systems are used globally in a wide variety of diesel engine

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

Thermostatic valve bodies

Thermostatic valve bodies Thermostatic valve bodies for single pipe heating systems Thermostatic valves with radiator connection systems IMI HEIMEIER / Thermostatic heads and Radiator valves / Thermostatic valve bodies for single

More information

HERZ Regulating valve 4002

HERZ Regulating valve 4002 HERZ Regulating valve 4002 Data sheet 4002, Issue 0214 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 42 1 4002 62 1 4002 43 1 4002 63 1 4002 44 1 4002 64 1 4002 45 1 4002 65 1 4002 46 1 4002 66 DN

More information

49 Danfoss Thermostat Kits Ranco Varifix Kits

49 Danfoss Thermostat Kits Ranco Varifix Kits Danfoss Thermostat Kits Code Type To Suit E005 NO-1 Kit Refrigerator E006 NO-2 Refrigerator Push/Defrost E007 NO-3 Fridge Freezer/Larder Fridge E008 NO-4 Absorption Refrigerator E009 NO-5 Freezer E010

More information

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25)

FLOAT AND THERMOSTATIC STEAM TRAPS FLT17 (DN 1/2 to 1 ; DN15 to DN25) LOAT AND THERMOSTATIC STEAM TRAPS LT17 (DN 1/2 to 1 ; DN15 to DN25) DESCRIPTION LT17 float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam

More information

TECHNICAL DATA OBSOLETE

TECHNICAL DATA OBSOLETE June 1, 2007 1. DESCRIPTION Viking Quick Response Fusible Element Pendent Sprinklers VK330, VK332, VK353 and HP Sprinklers VK318 and VK343 are small, thermosensitive, solder link spray sprinklers available

More information

SOLUTIONS GUIDE. For total efficiency

SOLUTIONS GUIDE. For total efficiency 2014-2015 SOLUTIONS GUIDE For total efficiency THERMOSTATIC RADIATOR HEADS Comap Thermostatic heads have been counted amongst the best sellers in Europe for decades, thanks to their high manufacturing

More information

GASTEC QA. Approval Requirements 6

GASTEC QA. Approval Requirements 6 KE 6 March 2012 GASTEC QA Approval Requirements 6 for the GASTEC QA product certificate for Plumbing fittings with ends for capillar soldering and/or thread connections Foreword These GASTEC QA Approval

More information

Series 20 Dual Check Backflow Preventers

Series 20 Dual Check Backflow Preventers Series 20 Dual Check Backflow Preventers Excellence Matters Specify It! A Division of Watts Regulator Company 427 North Market Blvd Suite #9 Sacramento, CA 9584 Phone: 96-928-02 Fax: 96-928-9 www.amesfirewater.com

More information

F4060 RESILIENT SEATED GATE VALVES

F4060 RESILIENT SEATED GATE VALVES F4060 RESILIENT SEATED GATE VALVES BS 5163 AS 2638 EN 1074 FM UL EN 1171 ISO 7259 The Keystone Figure 4060 series is a Tyco manufactured resilient seated gate valve available in a wide variety of configurations

More information

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, 70 0 90 R7 Size 70 7 9 0 90 Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

REFRIGERANT PIPING SYSTEM

REFRIGERANT PIPING SYSTEM PART 1 GENERAL 1.01 DESCRIPTION A. The requirements of this section apply to the refrigerant piping system connecting refrigeration and HVAC equipment specified in other sections of these specifications.

More information

Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system

Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system Thermoplastic K-LINK hoses and accessories for refrigeration and air conditioning system Bulletin ACH-GB The Air Conditioning / Refrigeration System The domestic and industrial Air Conditioning / Refrigeration

More information

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Data sheet Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16) Description XB06 IHPT The XB is a brazed plate heat exchanger designed for use with district heating systems

More information

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description Worldwide Contacts www.tyco-fire.com Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRL,

More information

Water Piping and Pumps

Water Piping and Pumps Technical Development Program DISTRIBUTION SYSTEMS Water Piping and Pumps PRESENTED BY: Michael Ho carriertdp@gmail.com 424-262-2144 Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section

More information

General Characteristics SM185S3QC. Dimensions. Terminal box. Electrical Characteristics. Recommended Installation torques

General Characteristics SM185S3QC. Dimensions. Terminal box. Electrical Characteristics. Recommended Installation torques Datasheet, technical data Performer scroll compressor, SM185-3 General Characteristics Model number (on compressor nameplate) Code number for Singlepack* Code number for Industrial pack** Drawing number

More information

IDU22C, 22C1, 37C, 37C1, 55C, 75C

IDU22C, 22C1, 37C, 37C1, 55C, 75C Refrigerated ir ryer Series IU edium IU, 1, 7, 71, 55, 75 () () () () () Run light Operation (ftercooler) Stop (ftercooler) Outlet air pressure gauge vaporation () (I) () Terminal block () () P rain port

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

General information on refrigerant controllers

General information on refrigerant controllers General information on refrigerant controllers Condensing pressure controller The condensing or condenser pressure controller is a back pressure controller and its task is to maintain the condensing pressure

More information

Honeywell Control Valve. HFP Asia Pacific

Honeywell Control Valve. HFP Asia Pacific Honeywell Control Valve HFP Asia Pacific Sep 25, 2014 CONTENTS 1. Products Range Valve Body 2. Products Linear Valve Type Specification Feature Rotary Valve Type Specification Feature Pneumatic Actuator

More information

CTC EcoZenith i550 Pro All-in-one tank with built-in, intelligent control.

CTC EcoZenith i550 Pro All-in-one tank with built-in, intelligent control. CTC EcoZenith i550 Pro ll-in-one tank with built-in, intelligent control. CTC EcoZenith i550 Pro can control all components in one or more heating systems: solar heating, pool, extra hot water, buffer

More information

Battery Interconnects

Battery Interconnects Battery Interconnects Product Facts Total interface solution Current capacity 7 Amps/ single contact at 30 C T-Rise Choice of right-angle or vertical mount headers with left, right or keyless polarization

More information