NEW VENTILATION AIR CONDITIONING AIR CLEANING HEATING SAP-Q APPENDIX Q ELIGIBLE

Size: px
Start display at page:

Download "NEW VENTILATION AIR CONDITIONING AIR CLEANING HEATING SAP-Q APPENDIX Q ELIGIBLE"

Transcription

1 NEW Vort PROMETEO PLUS HR400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING SAP-Q APPENDIX Q ELIGIBLE TM 1

2 TM VORT PROMETEO PLUS RANGE HEAT RECOVERY UNITS Product specifications: NEW 2 models: vort PROMETEO PLUS HR 400 vort PROMETEO PLUS hr 400 m. External Casing in polypropylene (PPE). Heat Exchanger Crossed Counter-Flow type, made of PS (Polystyrene). Extremely high heat recovery rate (up to 92%). Electronically controlled EC brushless motors independently adjustable. Max airflow 380 m 3 /h. 3 available speeds. Automatic frost protection. By-pass. Provided with 2 F5 filters (F7 optional). 0.5 m long silencer with nominal diameter of 150 mm supplied. Horizontal and Vertical installation. 2 mounting brackets for vertical installation and 4 feet for horizontal installation supplied. Protection rate: IPX2. Insulation class: Cl.II. BRE sap Q Vort PROMETEO PLUS HR 400: RF remote control supplied. 2 operating modes: automatic and manual. Automatic By-pass. Option of setting the temperature, humidity and CO 2 thresholds. Timer. Vort PROMETEO PLUS HR 400 M: Manually switched. Manual By-pass. Can be used in conjunction with Vortice ambient sensors. Requires RF remote controller and receiver (for commissioning only). 1 gang one way engraved switch. 2 gang two way engraved switch. Comply with the following European Directives: 2006/95/EC Low Voltage Directive (LVD) 2004/108/EC Electromagnetic Compatibility Directive (EMC) 2006/42/EC According to the following state-of-the-ar t Standards: Safety: EN , EN , EN , EN 62233, EN EMC: EN , EN , EN , EN PERFORMANCE: EN 308, EN

3 FUNCTIONS AND SUPPLIES VORT PROMETEO PLUS RANGE Normal operation mode By-pass mode Anti-Frost DIMENSIONS

4 REGULATION AND CONTROL VORT PROMETEO PLUS MODEL Each Vort Prometeo Plus feature is controlled by the radio frequency (RF) remote control. The RF remote control with LCD display featuring new integrated graphics can be used for the following purposes: Switching on/off. Selecting the appliance operating mode (Manual/Automatic). Easy initial setting of minimum and maximum speed (no need to directly operate the machine). Selecting one of the 3 speed settings. Selecting the By-pass function. Setting the Timer function (the product, working in Manual mode, will work at the maximum speed for: 10, 20, 30 or indefinitely, automatically slowing down to min speed). Configuring the automatic operating parameters: desired indoor temperature (for bypass management only) can be set by the user between +15 C and +30 C (each step 1 C); relative humidity can be set by the user between 40% and 90% (each step 5%); Max. CO 2 air concentration in the room can be set by the user between 500 ppm and ppm (at step of 50 ppm); CO 2 level can be disabled. Viewing machine malfunction information. An additional radio frequency (RF) antenna, part code (22479) including a connection cable, is available as an option, and allows control, of the Vort Prometeo Plus even if the position chosen for its installation is screened from radio waves. KEY FEATURES Offers continuous ventilation of the home. Energy saving thanks to brushless motors. Can be integrated into a residential home automation network (ModBus). Software can be easily updated through USB connection. The PCB is easily accessed by removing the bottom panel. Recommended application in residential buildings up to 200 m 2 and commercial buildings. Horizontal or vertical installation facilitated by the minimal weight of the appliance (just 25 kg). 4

5 filter specifications The air we breathe contains a huge number of potentially harmful particles, over 90% of them are smaller than 1 µm, for example: - Fine particles emitted by motor vehicles and heating systems. - Viruses. - Bacteria. it is very important to use air exchange systems with high-efficiency filters, which capture most of these toxic particles. Mechanically controlled ventilation systems such as VORT PROMETEO PLUS heat recovery units filters air as it enters the property, ensuring that in the occupied rooms it arrives at the ambient temperature, thus protecting the health and wellbeing of the occupants served by the appliance. Don t forget: Over time, filters become clogged, leading to a greater pressure loss in the air circuit; the filters therefore require regular maintenance and should be replaced when they are no longer effective. Filters can be split into 2 main categories, based on their filtering efficiency: - Type G: coarse filter - Type F: fine filter These categories are defined by European standard EN779. Within the two categories, a progressive number indicates the efficiency level of the filter: the higher the number, the more efficient the filter is at capturing particles, as you can see from the chart below. CERTIFICATIONS VORT PROMETEO PLUS HR 400 RANGE is constructed in compliance with the most recent standards which certify: The safety: EN : safety of electric appliances for domestic and similar use, part 1: General Standards; EN : safety of electric appliances for domestic and similar use, part 2: particular standards for fans; EN 50366: emissions potentially dangerous from electromagnetic fields (EMF); EN 60529: degrees of protection provided by enclosures (IP code). The electromagnetic compatibility (EMC): EN : electromagnetic emissions; EN : immunity to electromagnetic fields; EN : limits for harmonic current emissions; EN : limitation of voltage fluctuation and flickers. The performances: EN 308: heat exchangers performances; EN : fans performances; ADF (2010) System 4 - Continuous Mechanical Extract with Heat Recovery (MVHR) - applicable in England and Wales; Scottish Technical Handbook 2007; Section 3.14; TGD (2008) Part F-Ventilation-applicable in Ireland; BRE Digest 398-Continuous Mechanical Ventilation in dwellings. APPENDIX Q ELIGIBILITY The Prometeo PLUS HR 400 with its low energy DC motors and innovative design has been independently assessed by the Building Research Establishment (BRE) to the appropriate SAP Appendix Q test methodology and is Appendix Q eligible in all configurations from 1 to 8 additional wet rooms. 5

6 TECHNICAL DATA Max Airflow Max Pressure Models Code V ~ 50 Hz W A m3 /h l/s mmh 2 O Pa Kg Max C VORT PROMETEO PLUS HR VORT PROMETEO PLUS HR 400 M Sound levels* VORT PROMETEO PLUS RANGE RPM Lw db (A) 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Lw db (A) Supply to internal Extract from internal Lp db (A) 3m*** Breakout na** Supply to internal Extract from internal Breakout Supply to internal Extract from internal nd Breakout Supply to internal Extract from internal Breakout Supply to internal Extract from internal Breakout Supply to internal Extract from internal Breakout * Tests carried out using sound intensity measurement in a semi-anechoic chamber. ** Data not available. *** Free field condition. 6

7 SAP-Q DATA Standard Assessment Procedure - Appendix Q MVHR Product Data 01/06/2012 Result for SAP calculations (at minimum flow rate condition) This product has only benen tasted with rigid ductwork and the data are not applicablefor SAP calculations if installated with flexible ductwork. Table Q2 - Systems with rigid ductwork only Exhaust terminal configuration fan speed setting Specific fan power (W/l/s) Heat exchange efficiency (%) Energy Saving Trust Best Practice Performance Compliant 1 additional wet room Yes 2 additional wet rooms Yes 3 additional wet rooms Yes 4 additional wet rooms Yes 5 additional wet rooms Yes 6 additional wet rooms Yes 7 additional wet rooms Yes These figures are entered into either: (a) In the case of SAP software amended to SAP 2005 version 9.81 allowing direct entry of MVHR data, the SAP software, or (b) In the case of SAP software amended to SAP 2005 version 9.81 not allowing direct entry of MVHR data, the SAP Q MVHR Calculation Spreadsheet v9.81 and the results from the spreadsheet into the Special Features part of the SAP 9.81 software, or (c) In the case of SAP software to SAP 2005 version 9.80, the SAP Q MVHR Calculation Spreadsheet v9.80 and results from the spreadsheet into the Special Features part of the SAP 9.80 software. They must NOT be entered directly into SAP 2005 version 9.80 software. 7

8 performance curves VORT PROMETEO PLUS HR 400 M POWER CONSUMPTION CURVES VORT PROMETEO PLUS HR 400 M AIRFLOW/PRESSURE CURVES Power [W] p [mmh₂o] p [Pa] q [m³/h] q [l/s] q [m³/h] q [l/s] MAX-max (3350 RPM) MAX def (3070 RPM) MED def (2330 RPM) MIN def (1600 RPM) MIN-min (700 RPM) VORT PROMETEO PLUS HR 400 POWER CONSUMPTION CURVES VORT PROMETEO PLUS HR 400 AIRFLOW/PRESSURE CURVES Power [W] p [mmh₂o] p [Pa] q [m³/h] q [l/s] q [m³/h] q [l/s] 3350 RPM 3000 RPM 2650 RPM 2100 RPM 1600 RPM 700 RPM 8

9 ACCESSORIES VORT PROMETEO PLUS HR 400 M ONLY Description Code Models C TEMP-TEMPERATURE: Measures ambient room temperature, and starts the fan when the temperature exceeds the preset value. Once the temperature drops below the preset value, you can adjust the over-run timer from 3 to 20 minutes C SMOKE: Measures the air quality, detecting the presence of cigarette smoke, odours and other pollutants, and starts the fan when the concentration of pollutants exceeds the preset value. You can adjust the over-run timer from 3 to 20 minutes C HCS-HUMIDITY: Measures ambient relative humidity. It starts the fan when the R.H. It incorporates an over-run timer (adjustable between 3 and 20 minutes) c pir- movement detector: Detects the presence of a moving body within its sensor range, and starts the fan automatically. You can adjust the over-run timer from 3 to 20 minutes C TIMER: Adjustable over-run timer between 3 and 20 minutes A B C DIMENSIONS (mm) Code Model A B C C TEMP C SMOKE C HCS C PIR C TIMER Switch: 1 gang one way engraved switch switch: 2 gang two way engraved switch CONTROL: External RF Receiver Module CONTROL: RF Remote Controller White If external room sensors are connected, specific wiring is required. 9

10 Description Code Models EXTERNAL FILTER BOX F5 External Filter Box F5 FILTER (For external filter box) FILTERS F5 FILTER x F7 FILTER x HEAT EXCHANGER HEAT EXCHANGER screwdriver HEXAGONAL SCREWDRIVER FOR MAINTENANCE GREY FIXED GRILLE 125/150 mm Ø WHITE FIXED GRILLE 150 mm Ø 8224 BROWN FIXED GRILLE 150 mm Ø 8227 BEIGE FIXED GRILLE 150 mm Ø 8230 TERRACOTTA FIXED GRILLE 150 mm Ø 8233 WALL LINER 150 mm Ø 8180 SPIGOT PLATE 150 mm Ø 8136 EXTERNAL TERMINALS AND ASSOCIATED COMPONENTS FD 200 (204 x 60 mm) DOUBLE AIRBRICK ADAPTOR 8434 WHITE AIRBRICK INSERT (2 required for each Double Airbrick Adaptor) 8440 BROWN AIRBRICK INSERT (2 required for each Double Airbrick Adaptor) 8441 STONE AIRBRICK INSERT (2 required for each Double Airbrick Adaptor) 8442 TERRACOTTA AIRBRICK INSERT (2 required for each Double Airbrick Adaptor) FD 180 (180 x 90 mm) White Airbrick 9211 FD 180 (180 x 90 mm) Brown Airbrick 9212 FD 180 (180 x 90 mm) Stone Airbrick 9213 FD 180 (180 x 90 mm) Terracotta Airbrick 9214 ROOM TERMINAL duct valve 125 MM Ø - EXTRACT 9095 duct valve 125 MM Ø - SUPPLY 9096 y - piece 150 mm Ø 8683 ADDITIONAL DUCTING COMPONENTS reducer from 150 mm Ø to 125 mm Ø 9238 worm drive clip 125 mm Ø 8040 worm drive clip 150 mm Ø 8041 pvc tape 8020 thermally insulated flexible duct (only short off cts of flexible duct can be used) INSULATED FLEXIBLE DUCT 125 mm Ø - 4 m lengh 8342 INSULATED FLEXIBLE DUCT 125 mm Ø - 10 m lengh 8333 INSULATED FLEXIBLE DUCT 150 mm Ø - 4 m lengh 8341 INSULATED FLEXIBLE DUCT 150 mm Ø - 10 m lengh

11 Description Code Models FD200 (204 x 60 mm) 1 m Rigid Duct 8433 FD200 (204 x 60 mm) 1.5 m Rigid Duct 8430 FD200 (204 x 60 mm) Connector 8406 FD200 (204 x 60 mm) Horizontal T-Piece 8412 FD200 (204 x 60 mm) Round/Square 90 Bend 125 mm Ø 8417 FD200 (204 x 60 mm) Round/Square 90 Bend 150 mm Ø 8427 FD200 (204 x 60 mm) Round/Square Adaptor 125 mm Ø 8409 FD200 (204 x 60 mm) Horizontal 90 Bend 8414 flat ducting FD200 (204 x 60 mm) Horizontal 45 Bend 8420 FD200 (204 x 60 mm) Vertical 90 Bend 8408 FD200 (204 x 60 mm) Adjustable Bend 0.5 m lengh 8418 FD200 (204 x 60 mm) Mounting Stap 8419 FD180 (180 x90 mm) Duct 1 m lengh 9200 FD180 (180 x90 mm) Connector 9202 FD180 (180 x90 mm) Horizontal 90 Bend 9204 FD180 (180 x90 mm) Round/Square 90 Bend 150 mm Ø FD180 (180 x90 mm) Mounting Staps 9220 ROUND RIGID DUCT 125 mm Ø m lengh 9362 ROUND RIGID DUCT 150 mm Ø m lengh 9372 DUCT CONNECTOR 125 mm Ø 8415 DUCT CONNECTOR 150 mm Ø 9375 round rigid ducting 90 BEND 125 mm Ø BEND 150 mm Ø BEND 125 mm Ø 9363 T-PIECE 125 mm Ø 9360 ROUND RIGID DUCT SUPPORT CLIP 125 mm Ø 9364 ROUND RIGID DUCT SUPPORT CLIP 150 mm Ø 9374 ELECTRIC HEATER 500 W electric heater ELECTRIC HEATER 1200 W ELECTRIC HEATER 1800 W

12 Building Regulations Document F system 4 Continuous mechanical supply & extract ventilation with heat recovery A continuous balanced mechanical central supply and extract system to be positioned in loft or cupboard space. An integral heat exchanger recovers a large percentage of heat energy that would have otherwise been lost. In employing this type of system, there is no need to install background ventilators in the dwelling. 2 Calculate the whole dwelling extract rate at maximum operation by adding the individual room rates for minimum high rate from Table 5.1a. 3 The required air flow rates as as follows: Maximum Extract Rate (boost) is the greater step of 1 and 2 above. The Minimum individual room extract rates should be at least those given in Table 5.1a for minimum high rate. 4 No Background ventilators are required with System 4. Continuous supply and extract 1 For any design air permeability, determine the whole dwelling ventilation supply rate from Table 5.1b. As an alternative where the designed air permeability is intended to be leakier than (>) 5m 3 /(h.m 2 ) at 50 Pa, allow for infiltration for all dwelling types by subtracting from the whole dwelling ventilation supply rate from Table 5.1b: 0.04l/ (s.m 3 ) x gross internal volume of the dwelling heated space (m 3 ), but see the cautionary advice in Table 5.1a Table 5.1b Kitchen Room Minimum intermittent extract rate 30 l/s (adjacent to hob, 60 l/s elsewhere) Continuous rate Minimum high rate 13 l/s Utility room 30 l/s 8 l/s Bathroom 15 l/s 8 l/s Sanitary Accomodation 6 l/s 6 l/s Minimum low rate Total extract rate must be at least the whole building ventilation rate in Table 5.1b Whole building ventilation rate (l/s) Number of bedrooms in dwelling Minimum value in any dwelling of 0.3 l/s per m 2 floor area - In addition, the minimum ventilation rate should not be less than 0.3 l/s per m 2 internal floor area (this includes each floor, e.g. for a two-storey building, add the ground and first floor areas). - This is based on two occupants in the main bedroom and a single occupant in all other bedrooms. This should be used as the default value. If a greater level of occupance is expected, then add 4 l/s per occupant. Code /12 Vortice Elettrosociali S.p.A Strada Cerca, 2 Frazione di Zoate Tribiano (Milano) Tel. (+39) Fax (+39) Italia export@vortice-italy.com Vortice France 15-33, Rue Le Corbusier CS Créteil Cedex Tél. (+33) Fax (+33) France contact@vortice-france.com Vortice Limited Beeches House-Eastern Avenue Burton on Trent DE13 0BB Tel. (+44) Fax (+44) United Kingdom sales@vortice.ltd.uk The description and illustrations in this catalogue are understood to be indicative and are not binding. Vortice reserves the right, while not changing the essential characteristcs of the models described and illustred, to modify products whenever necessary and without warning.

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE NEW VORT PROMETEO HR 400 HEAT RECOVERY UNIT APPENDIX Q ELIGIBLE VENTILATION AIR CONDITIONING AIR CLEANING HEATING 2 VORT PROMETEO HR 400 (Code 11815) Quiet, Effective Ventilation in Full Compliance with

More information

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT

NEW VORT PROMETEO HR 400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING HEAT RECOVERY UNIT NEW VORT PROMETEO HR 400 HEAT RECOVERY UNIT VENTILATION AIR CONDITIONING AIR CLEANING HEATING 2 VORT PROMETEO HR 400 (Code 11815) Quiet, Effective with a Thermal Efficiency up to 92 % Energy Saving Lowers

More information

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

vortice.com RESIDENTIAL VENTILATION VORT HRW 20 MONO RANGE Decentralized heat recovery units NEW

vortice.com RESIDENTIAL VENTILATION VORT HRW 20 MONO RANGE Decentralized heat recovery units NEW vortice.com RESIDENTIAL VENTILATION VORT HRW 20 MONO RANGE Decentralized heat recovery units NEW A air is life We work to promote life quality and to contribute to the social evolution through eco-friendly

More information

AIR CONDITIONING AIR DOOR RANGE NEW

AIR CONDITIONING AIR DOOR RANGE NEW www.vortice.com AIR CONDITIONING AIR DOOR RANGE NEW www.vortice.com HEADQUARTERS VORTICE IN THE WORLD Founded in 1974, Vortice France is located at Crétail about 10 Km from Paris. Our current Vortice Headquarters

More information

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW NEW HRU ECO 3 RF ULTRA HIGH EFFICIENCY (95%) WHOLE HOUSE HEAT RECOVERY VENTILATION SYSTEM (MVHR) COMPLYING WITH SYSTEM 4 OF ADF2006 VENTILATION AIR CONDITIONING AIR CLEANING HEATING APPENDIX Q ELIGIBLE

More information

VORT PROMETEO PLUS HR400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING

VORT PROMETEO PLUS HR400 VENTILATION AIR CONDITIONING AIR CLEANING HEATING NEW VORT PROMETEO PLUS HR4 VENTILTION IR ONDITIONING IR LENING HETING TM 1 TM VORT PROMETEO PLUS RNGE HET REOVERY UNITS Product specifications: NEW 2 models: VORT PROMETEO PLUS HR 4 VORT PROMETEO PLUS

More information

vortice.com SUMMER VENTILATION NORDIK ECO RANGE Reversible ceiling fans NEW

vortice.com SUMMER VENTILATION NORDIK ECO RANGE Reversible ceiling fans NEW vortice.com SUMMER VENTILATION ECO RANGE Reversible ceiling fans NEW H ECO RANGE Reversible ceiling fans ECO range are reversible ceiling fans for residential and commercial applications. EC (brushless)

More information

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger WHHR150DC SAP Q Eligible WHOLE HOUSE HEAT RECOVERY UNIT FEATURES Highly efficient, low energy solution to condensation and pollutant control Continuous ventilation in kitchen plus up to 5 additional wet

More information

vortice.com RESIDENTIAL VENTILATION VORT HRW 20 MONO RANGE Decentralized heat recovery units NEW

vortice.com RESIDENTIAL VENTILATION VORT HRW 20 MONO RANGE Decentralized heat recovery units NEW vortice.com RESIDENTIAL VENTILATION VORT HRW 20 MONO RANGE Decentralized heat recovery units NEW A air is life We work to promote life quality and to contribute to the social evolution through eco-friendly

More information

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Kair VENTILATION LIMITED ieco 4 RANGE Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Weight As a result of the unique clamping construction in combination with

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) IMPROVING INDOOR AIR QUALITY IN NEW HOMES 1 NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and

More information

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation NUAIRE MVHR and Opposite Handed version ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due to its intelligent

More information

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO3 MRXBOX-ECO3 NUAIRE MVHR MRXBOX-ECO3 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

MRXBOXAB-ECO2 MRXBOX-ECO2

MRXBOXAB-ECO2 MRXBOX-ECO2 NUAIRE MVHR MRXBOX-ECO2 and Opposite Handed versions ACHIEVES 100% DUTY IN BYPASS MODE The has been designed with automatic 100% bypass as listed on the SAP Product Characteristics Database (PCDB). Due

More information

NEW VENTILATION AIR CONDITIONING AIR CLEANING HEATING

NEW VENTILATION AIR CONDITIONING AIR CLEANING HEATING NW Vort PROMTO PLUS HR4 VNTILTION IR ONITIONING IR LNING HTING TM 1 TM VORT PROMTO PLUS RNG HT ROVRY UNITS Product specifications: NW 2 models: vort PROMTO PLUS HR 4 vort PROMTO PLUS hr 4 m. xternal asing

More information

Building Regulations 2010: What it means to you.

Building Regulations 2010: What it means to you. Building Regulations 2010: What it means to you. Where are we going? Ongoing changes to the ADF (Approved Document F) will bring about several differences to the way in which we use Ventilation in both

More information

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions) NUAIRE MVHR (including opposite handed versions) ACHIEVES 100% DUTY IN BYPASS MODE and MRXBOXAB- ECO-LP1-OH are specically designed for apartment applications where space is a premium. The new MRXBOX95-LP1

More information

CVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible

CVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible CVE ECO 2 Range System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible CVE ECO 2 Applications The Itho extractor unit model CVE ECO 2 has been developed for use as a very quiet and

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1 (Standard Unit) MRXBOXAB-ECO-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The LP1

More information

Installation and Maintenance

Installation and Maintenance 1.0 INTRODUCTION MRXBOXAB-ECO-LP1SW (Standard Unit) MRXBOXAB-ECO-LP1-OHSW (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery for Ceiling Void Mounting Installation and Maintenance The

More information

Installation and Maintenance

Installation and Maintenance MRXBOX95B-LP1 (Standard Unit) MRXBOX95B-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Ceiling Void Mounting Installation and Maintenance The EMC Directive

More information

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE NEW ECO RANGE MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) Mechanical Ventilation with Heat Recovery Proud to Build British u Nuaire is a world leader in the design and manufacture of fans and ventilation

More information

ELECTRIC HEATING VORTICE

ELECTRIC HEATING VORTICE NEW NOVITÀ ELECTRIC HEATING VORTICE VENTILATION AIR CONDITIONING AIR CLEANING HEATING ELECTRIC HEATING Air is life We work to promote quality of life and to contribute to social evolution through eco-friendly

More information

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual 90000556/90000557 Issue 10 9/17 MODEL: DV72 R & L Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation:

More information

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket MRXBOX95-WH1 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT - WHOLE HOUSE HEAT RECOVERY UNIT 95% efficient, SAP Appendix Q compliant heat recovery unit.. 29 285 82 BENEFITS High efficiency 95% efficient, with DC motors using 5% less energy than traditional fans.

More information

Installation and Maintenance

Installation and Maintenance 38 70 = 100 410 = 60 1.0 INTRODUCTION MRXBOXAB-ECO4-AESW (Standard Unit) MRXBOXAB-ECO4-AEOHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting Installation and Maintenance

More information

HRV Enthalpy. Catalogue

HRV Enthalpy. Catalogue HRV Enthalpy Catalogue BM896 Iss 02 - Enthalpy MVHR Contents HRV1.35 Q Plus - Enthalpy...3 HRV2 Q Plus - Enthalpy...5 HRV3 Q Plus - Enthalpy...7 HRV10.25 Q Plus - Enthalpy...9 Heat Water vapour Gases and

More information

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

Apartment Ventilation. Microbox Continuous Mechanical Extract Units Apartment Ventilation "Microbox" Continuous Mechanical Extract Units v e n t i l a t i o n IPX4 Vectaire Ltd is a member of: ; Fan Manufacturers Association; Smoke Control Association; Residential Ventilation

More information

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation

More information

Short Form Catalogue & Price List 2018

Short Form Catalogue & Price List 2018 Short Form Catalogue & Price List 2018 DOMESTIC VENTILATION COMMERCIAL VENTILATION INDUSTRIAL VENTILATION HYGIENE UK Distribution Network See www.vortice.ltd.uk for the UK Distribution Network If you are

More information

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units CI/SfB (57.7) 1st Edition Vent-Axia MVHR Units Vent-Axia Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal MVHR Units Features & Benefits Manufactured in the UK Building Regulations

More information

MRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

MRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside MRXBOX95-WM2 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information

Installation and Maintenance

Installation and Maintenance 1.0 Introduction MRXBOX-ECO2 (Standard Unit) MRXBOX-ECO2-OH (Opposite hand Unit) MRXBOXAB-ECO2 (Standard Unit) MRXBOXAB-ECO2-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for

More information

MRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance

MRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance MRXBOX95AB-WH1 Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction

More information

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside MRXOX95-WH1 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The ow Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION 2 AERECO DX system DX SYSTEM A COMPLETELY NEW HEAT RECOVERY VENTILATION RANGE With the experience of a very innovative room-by-room demand

More information

Lo-Carbon Sentinel Kinetic Horizontal

Lo-Carbon Sentinel Kinetic Horizontal Lo-Carbon Sentinel Kinetic Horizontal MVHR Unit Features & Benefits Manufactured in the UK Building Regulations ADF compliant Recognised in SAP Appendix Q Energy Savings Trust best practice compliant Up

More information

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system Heat Recovery Ventilation Applicable to aircycle 1.1/1.2 (Ws - For Wall Mounting with In-built Control & Summer Bypass) Installation and Maintenance Instructions for the Installer. Please refer to the

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery for Wall Mounting

More information

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance MRXBOX95-WM2H Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0

More information

Building Regulations Approved Document F1 Means of Ventilation April 2006

Building Regulations Approved Document F1 Means of Ventilation April 2006 Building Regulations Approved Document F1 Means of Ventilation April 2006 BPD Structure BUILDING PRODUCT DESIGN LTD 4 trading divisions.. Natural ventilation products and systems Roofing products, flat

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4 (Standard Unit) MRXBOXAB-ECO4-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting Installation and Maintenance The EMC Directive

More information

Controlled mechanical ventilation GB 03

Controlled mechanical ventilation GB 03 RECUPER SLIM 2018 Controlled mechanical ventilation GB 03 ir conditioning Systems to install Recover... your wellbeing The home is a precious asset where we all spend a major time of your life. So it s

More information

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible HRU ECO 4 System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Weight As a result of the unique clamping construction in combination with the plastic/synthetic

More information

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside Installation and Maintenance MRXBOX95-WM1 (Standard Unit) MRXBOX95-WM1-OH (Opposite hand Unit) MRXBOX95AB-WM1 (Standard Unit) MRXBOX95AB-WM1-OH (Opposite hand Unit) Mechanical Ventilation Units with Heat

More information

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation Residential Carbon Friendly Ventilation SAP Q Eligible ventilation Whole House Mechanical Ventilation - MVHR, MEV, dmev SAP Q ELIGIBLE PRODUCTS Energy Efficient Ventilation About Appendix Q SAP is the

More information

InspirAIR Home RESIDENTIAL AIR PURIFICATION

InspirAIR Home RESIDENTIAL AIR PURIFICATION InspirAIR Home InspirAIR Home The fi rst Aldes connected solution for centralised air purifi cation which beats to the rhythm of your life. RESIDENTIAL AIR PURIFICATION CONTENTS Presentation........................................................

More information

Installation and Maintenance

Installation and Maintenance MRXBOXAB-ECO4-SW (Standard Unit) MRXBOXAB-ECO4-OHSW (Opposite hand Unit) Mechanical Ventilation Units with Heat Recovery and Heat Exchanger Bypass for Wall Mounting The EMC Directive 014/30/EU The Low

More information

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR) Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR) Contractors Requirements & Competency This section outlines the general Standards

More information

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Itho Advance heat recovery ventilation unit. comfortable. indoor climate Itho Advance heat recovery ventilation unit comfortable indoor climate Advance heat recovery ventilation unit In order to make modern dwellings more energy efficient the insulation and air tightness has

More information

HOTLINE:

HOTLINE: You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore

More information

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS

More information

Lo-Carbon Sentinel Kinetic Range Overview

Lo-Carbon Sentinel Kinetic Range Overview Lo-Carbon Sentinel Kinetic Range Overview Mechanical Ventilation with Heat Recovery Features & Benefits Manufactured in the UK Building Regulations ADF and ADL compliant Recognised in SAP Appendix Q Specific

More information

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System energisava 200 High Efficiency Whole House Heat Recovery System Joining the high efficiency energisava

More information

MODEL: BV400 Part No:

MODEL: BV400 Part No: MODEL: BV400 Part No: 90000312 Mechanical Ventilation with Heat Recovery Installation and Commissioning Manual PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT INDEX 1. Introduction... 3 2. General Instructions...

More information

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES The Range 1 HIGHEST INDOOR AIR QUALITY IN NEW HOMES NUAIRE S Q-AIRE Innovation at its best Since our inception in 1966, we have pioneered a number of new ventilation strategies and products now widely

More information

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR Whole House Mechanical Ventilation with Heat Recovery - MVHR WHHR125DC - Aera This MVHR - WHHR125DC - Aera - is an efficient, low energy solution to controlling condensation and pollution. It provides

More information

Small Room Heat Recovery Ventilation

Small Room Heat Recovery Ventilation Small Room Heat Recovery Ventilation Ideal for smaller spaces that would benefit from heat recovery, such as staff rooms or offices Version 3.1 2 Breathing Buildings Small Room Heat Recovery 3 Small Room

More information

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2 NUAIRE S MVHR Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2 Nuaire s First Fix and Acoustic Solution are designed to not only reduce noise but to improve the installation when wall or cupboard

More information

low energy environmentally friendly economical residential ventilation with EC motors June 2015 Issue 5

low energy environmentally friendly economical residential ventilation with EC motors June 2015 Issue 5 v e n t i l a t i o n low energy environmentally friendly economical residential ventilation with EC motors June 2015 Issue 5 low energy, environmentally friendly, economical, low carbon Whole House Mechanical

More information

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC DB Suspended heat recovery air handling units 2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.

More information

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG VORTICE PUNTO RANGE ➀ ➁ ➂ ➃ For intermittent or continuous ventilation of bathrooms, toilets, kitchens or utility rooms in domestic or commercial properties. 82 models available with or without the option

More information

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range. CI/SfB (57.7) 3rd Edition WINNER2011 Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range. Lo-Carbon Centra Allowing you to help the environment

More information

RESIDENTIAL VENTILATION DUCTING SOLUTIONS

RESIDENTIAL VENTILATION DUCTING SOLUTIONS RESIDENTIAL VENTILATION DUCTING SOLUTIONS NUAIRE S PEDIGREE ABOUT NUAIRE Nuaire have designed and manufactured innovative, quality products for home and overseas markets since 1963. The group has extensive

More information

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION 2 AERECO Room-by-room demand controlled heat recovery ventilation REVOLUTION IN THE WORLD OF HEAT RECOVERY VENTILATION Through its new ventilation

More information

Lo-Carbon Sentinel Kinetic Range Overview

Lo-Carbon Sentinel Kinetic Range Overview Lo-Carbon Sentinel Kinetic Range Overview Mechanical Ventilation with Heat Recovery Features & Benefits Manufactured in the UK Building Regulations ADF and ADL compliant Recognised in SAP Appendix Q. Specific

More information

HYGIENE RANGE HAND DRYERS AND HAIR DRYERS NEW

HYGIENE RANGE HAND DRYERS AND HAIR DRYERS NEW www.vortice.com HYGIENE RNGE HND DRYERS ND HIR DRYERS NE HEDQURTERS VORTICE IN THE ORLD Founded in 1974, Vortice France is located at Crétail about 10 Km from Paris. Our current Vortice Headquarters have

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent 01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed

More information

VENTILATION DESIGNED FOR CARE HOMES

VENTILATION DESIGNED FOR CARE HOMES CI/SfB (57) Uniclass Pr_65_67_29 October 2017................................ ............................................................................. Contents Ventilation designed for Care Homes

More information

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER Safety Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION

More information

The Sentinel Kinetic Horizontal Range

The Sentinel Kinetic Horizontal Range Lo-Carbon Sentinel Kinetic Horizontal Features & Benefits Manufactured in the UK Building Regulations DF compliant Recognised in SP PCDB Energy Savings Trust best practice compliant Up to 81% heat recovery

More information

SPECIFICATION GUIDE. Tel DOMUS VENTILATION

SPECIFICATION GUIDE. Tel DOMUS VENTILATION SPECIFICATION GUIDE Tel 3443 715 523 www.domusventilation.co.uk @DomusVent DOMUS VENTILATION Contents Introduction 3 Best Practice Guide 4 Indoor Air Quality 8 Mechanical Ventilation Products 9 DME Controls

More information

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent 01 Introduction Thank you for choosing EnviroVent The fastest growing ventilation company in the UK You are about to install a product that is designed to outlast the life-cycle of the building. Once installed

More information

Intelligent Air Solutions

Intelligent Air Solutions Uniclass L75 CI/SfB (57) X HRX-aQSB. May 06 Intelligent Air Solutions QUIET COMPACT EFFICIENT MANUFACTURED IN THE UK Applications Suitable applications Introducing Polypipe s new and highly efficient Silavent

More information

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h PRODUCT DATA COMFORT 40 BY NILAN Ventilation & passive heat recovery Domestic Passive heat recovery Ventilation < 40 m /h COMFORT 40 Product description The Comfort 40 is an energy-efficient ventilation

More information

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance MRXBOX95B-LOFT Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage directive 2006/95/EC 1.0 Introduction

More information

No Insulation Without Ventilation Peter Rickaby Rickaby Thompson Associates

No Insulation Without Ventilation Peter Rickaby Rickaby Thompson Associates Creating an Energy-Chic Home The Highgate Society, 8 February 2017 No Insulation Without Ventilation Peter Rickaby Rickaby Thompson Associates www.rickabythompson.com No Taxation Without Representation

More information

Domestic & Commercial Fans

Domestic & Commercial Fans Max. airflow l/s Axial Fan Centrifugal Fan Speed Controllable Reversible Airflow Page Number BF IF CF CBF BF 64 * 16 IF 64 * 16 EAF LV 23 * 169 ECF LV 31 * 169 CF 25 * 170 CBF 31 * 170 RVF 0 * * 171 BRAVO

More information

MRXBOX95-WH1 MECHANICAL VENTILATION WITH HEAT RECOVERY

MRXBOX95-WH1 MECHANICAL VENTILATION WITH HEAT RECOVERY MECHAICA VETIATIO WITH HEAT RECOVERY UP TO 95% EFFICIET, SAP APPEDIX Q RECOGISED. WA/CUPOARD MOUTIG DESIG FOR MEDIUM TO ARGE HOUSES & APARTMETS. 36 029 2085 8200 EEFITS is designed to provide optimised

More information

MRXBOX95AB-WH2 (with automatic summer bypass)

MRXBOX95AB-WH2 (with automatic summer bypass) MRXBOX95AB-WH (with automatic summer bypass) MRXBOX95AB-WH is designed to provide optimised balanced (supply and extract) mechanical ventilation with heat recovery. Tempered air is delivered into living

More information

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery. PRODUCT DATA COMBI 300 POLAR BY NILAN Ventilation with passive & active heat recovery Domestic Passive heat recovery Active heat recovery Ventilation < 350 m 3 /h Comfort heating Comfort cooling COMBI

More information

2013 innovation. Room-by-room demand controlled heat recovery ventilation

2013 innovation. Room-by-room demand controlled heat recovery ventilation 2013 innovation Room-by-room demand controlled heat recovery ventilation 2 Revolution in the world of heat recovery ventilation Through its new ventilation system, which combines heat recovery and room-by-room

More information

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans CI/SfB (57.7) 1st Edition A new generation of Lo-Carbon continuous running fans Lo-Carbon Response/SELV dmev Unit A new generation of Lo-Carbon continuous running fans Looking towards the future Vent-Axia

More information

COUNTER-FLOW, HIGH-EFFICIENCY HEAT RECOVERY UNIT IDEO ECOWATT

COUNTER-FLOW, HIGH-EFFICIENCY HEAT RECOVERY UNIT IDEO ECOWATT Whole house heat recovery unit with a high-efficiency heat exchanger up to 92% with constant airflow setting, very low consumption EC motor and low sound level. Provides a constant supply of fresh tempered

More information

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY Product Overview www.orcaenergy.eu MAXI Device for heat recovery MAXI is designed to provide permanent controlled air exchange by means of mechanical ventilation

More information

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 % Single-room heat recovery unit Air flow up to 59 CFM Heat recovery efficiency up to 96 % 2018 SINGLE-ROOM HEAT RECOVERY UNITS Features Efficient solution for supply and exhaust ventilation of enclosed

More information

CI/SfB (57.5) November 2008

CI/SfB (57.5) November 2008 CI/SfB (57.5) climate systems November 2008 High-comfort, low-energy ventilation An energy efficient, fresh, clean and healthy climate - all year round Ubbink Heat Recovery Ventilation (HRV) systems provide

More information

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV)

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV) CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV) NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and ventilation systems. We

More information

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning Sentinel Kinetic MVHR and Kinetic Plus MVHR Installation & Commissioning Stock Ref. N 438222 Kinetic B 443319 Kinetic BH 438342 Kinetic V 443028 Kinetic Plus B 443029 Kinetic Plus CV/CP PLEASE RETAIN THESE

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

Dee Fly Cube 300 and 370. Heat Recovery ventilation

Dee Fly Cube 300 and 370. Heat Recovery ventilation V E N T I L A T I O N Dee Fly Cube 300 and 370 Heat Recovery ventilation 2 Simple and streamlined design Perfect integration in dwelling The principle of heat recovery ventilation Heat recovery ventilation

More information

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions Commissioning Data: To be completed by the Commissioning Engineer. Refer to User / Homeowner Guide also supplied.

More information

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4. MRXBOX95-LH1/LH2 Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction Unit must

More information

IDEO 325 ECOWATT. Counter-flow, high-efficiency heat recovery unit IDEO 325 ECOWATT. Low noise. Heat recovery units. Wireless programmable control

IDEO 325 ECOWATT. Counter-flow, high-efficiency heat recovery unit IDEO 325 ECOWATT. Low noise. Heat recovery units. Wireless programmable control Counter-flow, high-efficiency heat recovery unit Whole house heat recovery unit with a high-efficiency heat exchanger up to 92% with constant flow, setting and very low consumption DC motor. Provides a

More information

BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION

BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION 2 ND EDITION 1 Contents 1. Purpose of this document 3 Page 2. Ventilation 4 3. Purpose provided ventilation 6 4. Natural ventilation- windows,

More information

Ventilation. Product Information

Ventilation. Product Information Ventilation Product Information Residential Lossnay Unit The Lossnay VL-220 Mechanical Ventilation with Heat Recovery (MVHR) unit is an energy efficient whole house ventilation solution which provides

More information

InspirAIR Home RESIDENTIAL AIR PURIFICATION

InspirAIR Home RESIDENTIAL AIR PURIFICATION InspirAIR Home InspirAIR Home The first Aldes connected solution for centralised air purification which beats to the rhythm of your life. RESIDENTIAL AIR PURIFICATION CONTENTS Presentation...P4 Contents

More information

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery. HRXD MVHR UNIT 2018 Mechanical Ventilation with Heat Recovery 1 All prices quoted exclude VAT and do not include trade discounts. www.domusventilation.co.uk HRXD Range HRXD MVHR Mounts onto a wall in either

More information