CATALOG WATER SOURCE HEAT PUMPS

Size: px
Start display at page:

Download "CATALOG WATER SOURCE HEAT PUMPS"

Transcription

1 CATALOG Fan coil UNITS WATER SOURCE HEAT PUMPS DIRECT EXPANSION 2014

2 An InternatIonaL sales network NORD-PAS- DE-CALAIS PICARDIE HAUTE- NORMANDIE BASSE- NORMANDIE Tillières-sur-Avre ILE-DE-FRANCE Guyancourt CHAMPAGNE- ARDENNE LORRAINE BRETAGNE PAYS-DE- LOIRE CENTRE BOURGOGNE FRANCHE- COMTE POITOU- CHARENTE Pons LIMOUSIN AUVERGNE RHÔNES- ALPES AQUITAINE MIDI- PYRENEES PROVENCE-ALPES- CÔTE-D'AZUR LANGUEDOC- ROUSSILLON Commercial: Aftersales: 33 (0) Airwell France SAS 1 bis avenue du 8 mai Guyancourt - FRANCE Tel. +33 (0) Fax +33 (0)

3 Wesper quality innovation & QUalitY Innovation and Quality are one important parts of Wesper s philosophy. Spending all our energy to continuously develop innovative products for our customer will ensure our market position. More than 130 people are devoted to study products with a special are to the energy efficiency and acoustic emission issues for a better quality of life. Certifications The company plants are ISO 9001 certified by most recognised certification bodies and participates in the renowned Eurovent Certification program, a voluntary initiative which ensures that capacity ratings and design properties have been verified by independent laboratories according to international standards. technology & environment Wesper s primary objective is to design and offer air conditioning systems that meet both the highest standards of environmental protection and users legitimate expectations in terms of comfort and wellbeing. For Wesper, innovation has to be linked tightly to a respect for the environment and must include stringent requirements in terms of quality levels. This ongoing concern governs all our actions and involves all our human and technological resources. In accordance with this principle and with European Directives, in its appliances, Wesper uses ecological refrigerant fluids of the HFC type (R410A & R407C) that do not harm the planet s ozone layer. Moreover, with a constant care for participating in preserving the environment, Wesper designs and markets high efficiency products that reduce CO2 emissions into the atmosphere and minimize our contribution to global warming. environment ENERGY SAVING Spare Parts: the optimal reactivity Providing spare parts from Wesper origin is critical for good reliability and long life of our machines. That is why we have installed our European spare parts centre in France in Tillières (100 km West from Paris) on a factory site. With more than references in stock and very professional teams dedicated to customer service, we can deliver parts in Europe within 2 to 3 days after validating customer order (depending on the availability and specific constraints linked to the weight and size of the component). Spare parts department could be reached by: Fax: +33 (0) ; Letter at following address: AIRWELL France SAS, Spare Parts Department, Route de Verneuil, Tillières sur Avre, FRANCE. preairwell-group.com A technical support able to answer to all requests On the French territory Wesper CAC business has a network of more than 10 ASTS companies with a good knowledge of our products and trained on a regularly basis. They are able to provide service like start-up for all machines of our professional product range like chillers, rooftops, Heat pump In the meantime, we offer for our French and Export customers a technical phone support given by our Technical after sales experts for all questions relative to installation, commissioning or maintenance. For French customers they are available at following number: from 8.30 AM to PM and from 2 PM to 5 PM, from Monday to Friday. For Export customers, you have to dial For any specific question which requires a deeper expertise, we are able to arrange a travel on site by one of out technical expert in after sales in order to study with the installer the main causes of the request and the solution to be implemented. HEAT RECOVERY plug & play 4 5

4 Our History 1947 Paul Wallet founded L Air Conditionné Entreprise which later became the core of Airwell Group The Company developed and began the mass production of the first window unit, to offer exceptional climate conditions, mainly dedicated to European and African markets Airwell developed a split system unit by splitting its core window unit in two parts, and was the first to produce wall split systems in Europe Airwell entered the commercial and industrial markets with large cooling capacity for packaged air and water-cooled systems After the two oil crises in the 70s Airwell developed the first high-efficiency air to water heatpump to be connected to existing oil boilers in residential housing for oil energy saving Airwell designed and produced the first European wall split system range including electronic remote control, a high technology cross-flow fan for low noise levels, and rotary compressors. Founded in 1947, Airwell Group is one of the globally leading manufacturers and distributors of air conditioners and central air conditioning systems. The company has production facilities and marketing subsidiaries worldwide. Contents WATER TERMINAL UNITS Kw page Water terminal units selection guide 12 AquaFan II AWC/AHC STD Fan coil 1,9/9 14 AquaFan IIAWC/AHC EC Fan coil 1,9/5,7 16 AquaFan II AWN/AHN STD Fan coil 1,9/9 18 AquaFan II AWN/AHN EC Fan coil 1,9/5,7 20 AquaFan All Electrical Version Fan coil 1,1/7,2 22 Accessories AquaFan Fan coil 24 WKW LN STD 4 way chilled water cassette 2,3/10,2 28 WKW LN EC 4 way chilled water cassette 2,2/4,6 30 KCO2 1 way chilled water cassette 1,1/3,3 34 KCO2 EC 1 way chilled water cassette 0,8/3,8 36 Hawair High wall chilled water unit 2,2/4,7 38 DUCTYS Pressure ductable fan coil unit 1,2/3,3 40 VH STD High static pressure dectable fan 2,1/28,4 42 VH EC High static pressure dectable fan 5,5 44 Accessories DUCTYS and VH 5,5 46 VPN Fan coil unit 1,8/12, /1996 The Group grew with the acquisition of Spanish, Italian, German and French distribution companies, as well as the factory in Tillieres. 1998/2001 The Group strengthened its position by acquiring production facilities in China, France (Wesper) and Italy, and extended its distribution network in Argentina and Turkey. 2004/2006 In order to accentuate its position in the market, the Group opened an office in Russia and acquired Polenz Klimatechnik in Germany The Group reinforced its position in the American continent by acquiring the Fedders Residential Business (USA). WATER SOURCE HEAT PUMPS Water source heat pumps selection guide 54 STORM 2 Electronic control 56 EFTYS Water source heat pump 1,9/3 58 HRW Water source heat pump 5,3/30 62 EWH Water source heat pump 3,9/43 66 CW-AR Water source heat pump 1,9/2,7 68 DK DN Air-to-air split system 12/83 72 XAR UC Vertical air cabinet 9,7/55 76 XAO Vertical water cabinet 8/45,7 78 CDN Air-cooled condensing chiller 19/83 80 Generals TERMS 84 page 6 7

5 Water Terminal Units 8 9

6 A LARGE RANGE TO OFFER A SOLUTION FOR HEACH NEED Innovation AND EASY INSTALLATION WIDE RANGE OF CONTROL A large range of terminal units dedicated to energy saving and comfort: Low consumption solution with: High efficiency fan motor available on fan coil, ducted fan coil and cassette range High level of energy performance with mainly Energy class A or B Same thermal performance as with AC fan motor Blue fin coils on all terminal range for efficient and hygienic solution Silence Optimized fan speed staging for new low noise versions Reinforced acoustical insulation Profiled air diffuser Cost-optimized 3-speed setting for EC fan Control ready-to-install Play diffuser with grill on hinges FACTORY FACILITIES DEDICATED TO FLEXIBILITY AND QUALITY Many factory-mounted options or accessories: Control Valve Air diffuser Condensate drain pump Airwell Group is engaged in a permanent research of energy saving on and all around his product range. This logo is the witness of this voluntary gait in terms of: Engagement Efficiency Energy Products fully customized to satisfy your requirements: Choice of service side for hydraulic and electric connection Version with or without cabinet On-board control 100% units are tested electrically and acoustically. All Terminals Units are according to Eurovent standard

7 Water terminal units SElection GUIDE WATER terminal UNITS 0KW KW A20 1,9 kw NR 31 at HS m³/h LxHxW : 768x478x231 Chilled water cassette Fan coil Units KCO2 WKW AQUAFAN II TTE AQUAFAN II HOTEL HOTEL OFFICES OFFICES HOSPITAL HOSPITAL A30 A40 A50 A60 A70 A80 A20 E A40 E A60 E WKW LN WKW LN WKW LN WKW LN WKW LN KCO2 60 KCO2 90 KCO ,4 kw 3,5 kw 4,2 kw 5,2 kw 7,2 kw 9 kw 2,3 kw 4,5 kw 7,2 kw 0KW KW 2,3 kw 3,5 kw 4,6 kw 6,4 kw 10,2 kw 1,6 kw 3,2 kw 4,1 kw NR 36 at HS NR 29 at HS NR 33 at HS NR 39 at HS NR 41 at HS NR 44 at HS NR 29 at HS NR 30 at HS NR 42 at HS NR 27 at HS NR 27 at HS NR 28 at HS NR 37 at HS NR 40 at HS NR 28 at HS NR 23 at HS NR 23 at HS m³/h m³/h m³/h m³/h m³/h m³/h m³/h m³/h m³/h m³/h m³/h m³/h m³/h m³/h m³/h m³/h m³/h 0-30Pa EC 0-40Pa 0-Pa N/A N/A EC 0-Pa 0-Pa EC LxHxW : 935x478x231 LxHxW : 1138x478x231 LxHxW : 1323x478x231 LxHxW : 1508x478x231 LxHxW : 1323x578x231 LxHxW: 1508x478x231 LxHxW : 768x478x231 LxHxW : 1138x478x231 LxHxW : 1508x478x231 LxPxW : 625x625x287 LxPxW : 625x625x287 LxPxW : 625x625x287 LxPxW : 1225x625x287 LxPxW : 1225x625x287 LxPxW : 492x492x309 LxPxW : 970x492x309 LxPxW : 1192x492x309 0KW KW High wall chilled water unit HAWAIR HOTEL HAW 07 HAW 09 HAW 18 HAW 22 2,2 kw 2,9 kw 3,6 kw 4,7 kw NR 27 at HS NR 29 at HS NR 35 at HS NR 41 at HS m³/h m³/h m³/h m³/h 0-Pa N/A LxPxW : 845x275x180 LxPxW : 845x275x180 LxPxW : 940x298x200 LxPxW : 940x298x200 0KW KW LxHxP : 1138x478x231 High static pressure ductable fancoil unit DUCTYS VH OFFICES FACTORY DUCTYS 1500 DUCTYS 2000 DUCTYS 2500 VH07 VH15 VH18 VH21 VH24 2 kw 2,5 kw 3,3 kw 6,2 kw 14,8 kw 18,9 kw 21,9 kw 23,9 kw NR 30 at HS NR 31 at HS NR 31 at HS NR 34 at HS NR 40 at HS NR 40 at HS NR 40 at HS NR 44 at HS m³/h m³/h m³/h m³/h m³/h m³/h m³/h m³/h 0-80Pa 0-150Pa EC EC LxPxW : 581 x 640 x 223 LxPxW : 581 x 740 x 223 LxPxW : 581 x 840 x 223 LxPxW : 698x1200x250 LxPxW : 798x1380x375 LxPxW : 798x1380x375 LxPxW : 798x1380x375 LxPxW : 798x1500x450 VH27 28,4 kw NR 44 at HS m³/h LxPxW : 798x1500x450 Total cooling capacity at HS, Eurovent conditions

8 Fan coil units AquaFan II AWC/AHC STD FAN COIL UNIT COOLING AND HEATING AquaFan II AWC/AHC STD Size CAPACITIES - 2 Pipe V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 Total cooling capacity W 1040 / 1470 / / 2130 / / 2620 / / 2800 / / 4390 / / 5610 / / 6650 / 9040 Cooling (1) Sensible capacity W 750 / 1110 / / 1560 / / 1970 / / 1920 / / 2860 / / 4170 / / 4920 / 6890 Water flow l/h 178 / 215 / / 367 / / 450 / / 482 / / 753 / / 765 / / 1142 / 1548 Water pressure drop kpa 3 / 5 / 8 7 / 12 / / 20 / 33 8 / 14 / / 26 / 42 8 / 16 / / 23 / 39 Heating (2) Heating capacity W 1240 / 2020 / / 2610 / / 3500 / / 3710 / / 5250 / / 6900 / / 8360 / OFFICES CAPACITIES - 4 Pipe Total cooling capacity W 1080 / 1540 / / 2080 / / 2560 / / 3250 / / 4290 / / 5470 / / 6490 / 8830 Cooling (1) Sensible capacity W 760 / 1140 / / 1520 / / 1920 / / 2370 / / 280 / / 4060 / / 4780 / 6710 Water flow l/h 184 / 266 / / 356 / / 439 / / 558 / / 735 / / 940 / / 1113 / 1516 Cooling Capacity: from 1.9 to 9.0 kw Heating Capacity: from 2.3 to 11.6 kw Sizes: 7 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Vertical console with cabinet Ceiling exposed with cabinet Product Avantages HOTEL Ease of installation. Harmonuous and aesthetic RAL9003 painted cabinet design. Streamlined design and elaborate finish enabling harmonious integration. 5-speed AC fan motor. Very low operating acoustical levels. Airflow rate between 140 and 1400 m³/h. Selection of service side. Coil with hydrophilic fins to improve the condensate flow. Main Options 3-row coil for optimized cooling performances. Electrical heater with inserted heating rod - 4 heating capacity available per model. 2-stage heater available with Aqu@net control. AC motor. Selection of 3 speed. Large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus Communication interface board. 2-way or 3-way ON/OFF valve. G2 filter. Front or bottom air intake configuration. Motorized or manual fresh air damper. Auxiliary condensate drain pan. Condensate drain pump. Fuse holder. Main Accessories Valve. Control. Electrical heater. Drain pan. Condensate drain pump. Selection Software Select It. Water pressure drop kpa 14 / 27 / 42 7 / 12 / / 19 / 31 8 / 13 / / 25 / 40 8 / 15 / / 22 / 38 Heating (3) Water flow l/h 121 / 174 / / 246 / / 327 / / 428 / / 448 / / 461 / / 8280 / 1014 Heating capacity W 1390 / 1980 / / 2800 / / 3730 / / 4010 / / 5110 / / 5270 / / 9430 / Water pressure drop kpa 2 / 4 / 6 6 / 9 / 13 13/ 17 / / 32 / 50 8 / 11 / 15 9 / 15 / / 33 / 48 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 34/43/53 37/48/56 37/42/52 37/45/55 43/52/61 46/54/65 49/56/66 FANS (LS/MS/HS) Sound pressure level (4) db(a) 26/35/45 29/40/48 29/34/44 29/37/47 35/44/53 38/46/57 41/48/58 NR (4) db(a) 22/31/41 24/36/44 24/29/39 23/33/43 31/39/48 34/41/52 36/44/54 Number Airflow m³/h 132/223/ /290/ /385/ /471/ /650/ /799/ /934/1376 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230 / 1 / 50 Fan consumption W 5/12/27 10/20/33 7/15/35 8/19/45 18/30/72 92/110/150 90/112/188 Electrical heater (max) W WATER CONNECTIONS Type Gas female threaded DIMENSIONS WEIGHT Cooling coil inches 1/2" Heating coil inches 1/2" LxWxH mm 768 x 478 x x 478 x x 478 x x 478 x x 478 x x 578 x x 578 x 231 Unit weight kg (1) According to Eurovent standard: Air: 27 C DB/19 C WB, Water in: 7 C/12 C. (2) According to Eurovent standard: Air: 20 C, Water in: 50 C, same water flow as in cooling. (3) According to Eurovent standard: Air: 20 C, Water in: 70 C/60 C. (4) Sound pressure for console unit considering a local of 100 m ³, a reverberation time of 0,5 sec and a distance of 1 m. NEW: on stock! Configuration: 2 or 4-pipes, terminal block, without valve, left service side. Accessories for customization on site also available on stock - See page 26 and 27. Please consult us to get the last updated information on leadtime. Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) +5 C +90 C 17 bars 5 C/15% RH 32 C/70% RH AquaFan II Pipe Without valve AWC AHC 7OG OG OG OG OG Price Pipe Without valve AWC AHC 7OG OG OG OG OG Price On stock 14 15

9 Fan coil units AquaFan II AWC/AHC EC FAN COIL UNIT COOLING AND HEATING Cooling Capacity: from 1.9 to 5.7 kw Heating Capacity: from 2.3 to 7.4 kw Sizes: 5 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Vertical console with cabinet Ceiling exposed with cabinet Product Avantages OFFICES HOTEL Ease of installation. Harmonuous and aesthetic RAL9003 painted cabinet design. Streamlined design and elaborate finish enabling harmonious integration. Low consumption EC fan motor. Very low operating acoustical levels. Airflow rate between 140 and 900 m³/h. Selection of service side. Coil with hydrophilic fins to improve the condensate flow. Main Options 3-row coil for optimized cooling performances. Electrical heater with inserted heating rod 4 heating capacity available per model. 2-stage heater available with Aquanet control. EC motor. Selection of 3 speed with ECospeed3 board. Large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus Communication interface board. 2-way or 3-way ON/OFF valve. G2 filter. Front or bottom air intake configuration. Motorized or manual fresh air damper. Auxiliary condensate drain pan. Condensate drain pump. Main Accessories Valve. Control. Electrical heater. Drain pan. Condensate drain pump. Selection Software Select It. AquaFan II AWC/AHC EC Size CAPACITIES - 2 Pipe Total cooling capacity W 1040 / 1470 / / 2130 / / 2620 / / 2800 / / 4390 / 5730 Sensible capacity W 750 / 1110 / / 1560 / / 1970 / / 1920 / / 2860 / 3850 Cooling (1) Water flow l/h 178 / 215 / / 367 / / 450 / / 482 / / 753 / 983 Water pressure drop kpa 3 / 5 / 8 7 / 12 / / 20 / 33 8 / 14 / / 26 / 42 Heating (2) Heating capacity W 1240 / 2020 / / 2610 / / 3500 / / 3710 / / 5250 / 7360 CAPACITIES - 4 Pipe Total cooling capacity W 1080 / 1540 / / 2080 / / 2560 / / 3250 / / 4290 / 5610 Sensible capacity W 760 / 1140 / / 1520 / / 1920 / / 2370 / / 280 / 3770 Cooling (1) Water flow l/h 184 / 266 / / 356 / / 439 / / 558 / / 735 / 961 Water pressure drop kpa 14 / 27 / 42 7 / 12 / / 19 / 31 8 / 13 / / 25 / 40 Heating (3) Water flow l/h 121 / 174 / / 246 / / 327 / / 428 / / 448 / 531 Heating capacity W 1390 / 1980 / / 2800 / / 3730 / / 4010 / / 5110 / 6060 Water pressure drop kpa 2 / 4 / 6 6 / 9 / 13 13/ 17 / / 32 / 50 8 / 11 / 15 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 34/43/53 37/48/56 37/42/52 37/45/55 43/52/61 Sound pressure level (4) db(a) 26/35/45 29/40/48 29/34/44 29/37/47 35/44/53 NR (4) db(a) 22/31/41 24/36/44 24/29/39 23/33/43 31/39/48 FANS (LS/MS/HS) Number Airflow m³/h 132/223/ /290/ /385/ /471/ /650/917 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230 / 1 / 50 Fan consumption W 5/12/27 10/20/33 7/15/35 8/19/45 18/30/72 Set voltage V 1,7 / 3,3 / 5,5 3,1 / 4,9 / 8,2 2,4 / 3,9 / 6,2 2,8 / 4,9 / 7,5 4,5 / 6,0 / 8,9 Electrical heater (max) W WATER CONNECTIONS Type Gas female threaded Cooling coil inches 1/2" Heating coil inches 1/2" DIMENSIONS LxWx mm 768 x 478 x x 478 x x 478 x x 478 x x 478 x 231 WEIGHT Unit weight kg (1) According to Eurovent standard: Air: 27 C DB/19 C WB, Water in: 7 C/12 C. (2) According to Eurovent standard: Air: 20 C, Water in: 50 C, same water flow as in cooling. (3) According to Eurovent standard: Air: 20 C, Water in: 70 C/60 C. (4) Sound pressure for console unit considering a local of 100 m ³, a reverberation time of 0,5 sec and a distance of 1 m. Accessories for customization on site also available on stock - See page 26 and 27. Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +90 C 17 bars Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) 5 C/15% RH 32 C/70% RH 16 17

10 Fan coil units AquaFan II AWN/AHN STD FAN COIL UNIT COOLING AND HEATING AquaFan II AWN/AHN STD Size CAPACITIES - 2 Pipe V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 Cooling (1) Total cooling capacity W 1040 / 1470 / / 2130 / / 2620 / / 2800 / / 4390 / / 5610 / / 6650 / 9040 Sensible capacity W 750 / 1110 / / 1560 / / 1970 / / 1920 / / 2860 / / 4170 / / 4920 / 6890 Water flow l/h 178 / 215 / / 367 / / 450 / / 482 / / 753 / / 765 / / 1142 / 1548 Water pressure drop kpa 3 / 5 / 8 7 / 12 / / 20 / 33 8 / 14 / / 26 / 42 8 / 16 / / 23 / 39 OFFICES Heating (2) Heating capacity W 1240 / 2020 / / 2610 / / 3500 / / 3710 / / 5250 / / 6900 / 9180 CAPACITIES - 4 Pipe 5990 / 8360 / HOTEL Cooling (1) Total cooling capacity W 1080 / 1540 / / 2080 / / 2560 / / 3250 / / 4290 / / 5470 / / 6490 / 8830 Sensible capacity W 760 / 1140 / / 1520 / / 1920 / / 2370 / / 280 / / 4060 / / 4780 / 6710 Water flow l/h 184 / 266 / / 356 / / 439 / / 558 / / 735 / / 940 / / 1113 / 1516 Cooling Capacity: from 1.9 to 9.0 kw Heating Capacity: from 2.3 to 11.6 kw Sizes: 7 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Vertical concealed without cabinet Ceiling concealed without cabinet Product Avantages Ease of installation. 5-speed AC fan motor. Very low operating acoustical levels. Airflow rate between 140 and 1400 m³/h. Selection of service side. Coil with hydrophilic fins to improve the condensate flow. Main Options 3-row coil for optimized cooling performances. Electrical heater with inserted heating rod - 4 heating capacity available per model. 2-stage heater available with Aquanet control. AC motor. Selection of 3 speed. Large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus Communication interface board. 2-way or 3-way ON/OFF valve. G2 filter. Various air intake configuration. Ducted plenum for air intake or dischage. Motorized or manual fresh air damper. Auxiliary condensate drain pan. Condensate drain pump. Main Accessories Valve. Control. Electrical heater. Drain pan. Condensate drain pump. Choice of ducted plenum for air intake or dischage. Selection Software Select It. Water pressure drop kpa 14 / 27 / 42 7 / 12 / / 19 / 31 8 / 13 / / 25 / 40 8 / 15 / / 22 / 38 Heating capacity W 1390 / 1980 / / 2800 / / 3730 / / 4010 / / 5110 / / 5270 / / 9430 / Heating (3) Water flow l/h 121 / 174 / / 246 / / 327 / / 428 / / 448 / / 461 / / 8280 / 1014 Water pressure drop kpa 2 / 4 / 6 6 / 9 / 13 13/ 17 / / 32 / 50 8 / 11 / 15 9 / 15 / / 33 / 48 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 34/43/53 37/48/56 37/42/52 37/45/55 43/52/61 46/54/65 49/56/66 Sound pressure level (4) db(a) <15/24/32 16/27/35 16/21/31 16/24/34 22/31/40 27/35/44 28/35/45 NR (4) db(a) <15/19/28 <15/23/31 <15/16/26 <15/20/30 18/26/35 23/30/39 23/31/41 FANS (LS/MS/HS) Number Airflow m³/h 132/223/ /290/ /385/ /471/ /650/ /799/ /934/1376 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230/1/50 Fan consumption W 16/27/45 24/40/60 33/39/57 39/45/66 41/64/107 92/110/150 90/112/188 Electrical heater (max) W WATER CONNECTIONS Type Gas female threaded Cooling coil inches 1/2" Heating coil inches 1/2" DIMENSIONS LxWxH mm 510 x 430 x x 430 x x 430 x x 430 x x 430 x x 530 x x 530 x 220 WEIGHT Unit weight kg (1) According to Eurovent standard: Air: 27 C DB/19 C WB, Water in: 7 C/12 C. (2) According to Eurovent standard: Air: 20 C, Water in: 50 C, same water flow as in cooling. (3) According to Eurovent standard: Air: 20 C, Water in: 70 C/60 C. (4) Sound pressure for console unit considering a local of 100 m ³, a reverberation time of 0,5 sec and a distance of 1 m. NEW: on stock! Configuration: 2 or 4-pipes, terminal block, without valve, left service side. Accessories for customization on site also available on stock - See page 26 and 27. Please consult us to get the last updated information on leadline. Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +90 C 17 bars AquaFan II Pipe Without valve AWN AHN 7OG OG OG OG OG Price Pipe Without valve AWN AHN 7OG OG OG OG OG Price On stock Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) 5 C/15% RH 32 C/70% RH 18 19

11 Fan coil units AquaFan II AWN/AHN EC FAN COIL UNIT COOLING AND HEATING Cooling Capacity: from 1.9 to 5,7 kw Heating Capacity: from 2.3 to 7,4 kw Sizes: 5 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Vertical concealed without cabinet Ceiling concealed without cabinet Product Avantages Ease of installation. Low consumption EC fan motor. Very low operating acoustical levels. Airflow rate between 140 and 900 m³/h. Selection of service side. Coil with hydrophilic fins to improve the condensate flow. OFFICES HOTEL Main Options 3-row coil for optimized cooling performances. Electrical heater with inserted heating rod - 4 heating capacity available per model. 2-stage heater available with Aqu@net control. EC motor. Selection of 3 speed with ECospeed3 board. Large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus Communication interface board. 2-way or 3-way ON/OFF valve. G2 filter. Front or bottom air intake configuration. Ducted plenum for air intake or dischage. Motorized or manual fresh air damper. Auxiliary condensate drain pan. Condensate drain pump. Main Accessories Valve. Control. Electrical heater. Drain pan. Condensate drain pump. Choice of ducted plenum for air intake or dischage. Selection Software Select It. AquaFan II AWN/AHN EC Size CAPACITIES - 2 Pipe V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 V5 / V3 / V1 Total cooling capacity W 1040 / 1470 / / 2130 / / 2620 / / 2800 / / 4390 / 5730 Sensible capacity W 750 / 1110 / / 1560 / / 1970 / / 1920 / / 2860 / 3850 Cooling (1) Water flow l/h 178 / 215 / / 367 / / 450 / / 482 / / 753 / 983 Water pressure drop kpa 3 / 5 / 8 7 / 12 / / 20 / 33 8 / 14 / / 26 / 42 Heating (2) Heating capacity W 1240 / 2020 / / 2610 / / 3500 / / 3710 / / 5250 / 7360 CAPACITIES - 4 Pipe Total cooling capacity W 1080 / 1540 / / 2080 / / 2560 / / 3250 / / 4290 / 5610 Sensible capacity W 760 / 1140 / / 1520 / / 1920 / / 2370 / / 280 / 3770 Cooling (1) Water flow l/h 184 / 266 / / 356 / / 439 / / 558 / / 735 / 961 Water pressure drop kpa 14 / 27 / 42 7 / 12 / / 19 / 31 8 / 13 / / 25 / 40 Heating (3) Water flow l/h 121 / 174 / / 246 / / 327 / / 428 / / 448 / 531 Heating capacity W 1390 / 1980 / / 2800 / / 3730 / / 4010 / / 5110 / 6060 Water pressure drop kpa 2 / 4 / 6 6 / 9 / 13 13/ 17 / / 32 / 50 8 / 11 / 15 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 34 / 43 / / 48 / / 42 / / 45 / / 52 /61 Sound pressure level (4) db(a) <15 / 24 / / 27 /35 16 / 21 / / 24 / / 31 / 40 NR (4) db(a) <15 / 19 / 28 <15 / 23 / 31 <15 / 16 / 26 <15 / 20 / / 26 / 35 FANS (LS/MS/HS) Number Airflow m³/h 132 / 223 / / 290 / / 385 / / 471 / / 650 / 917 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230 / 1 / 50 Fan consumption W 5 / 12 / / 20 / 33 7 / 15 / 35 8 / 19 / / 30 / 72 Set voltage V 1,7 / 3,3 / 5,5 3,1 / 4,9 / 8,2 2,4 / 3,9 / 6,2 2,8 / 4,9 / 7,5 4,5 / 6,0 / 8,9 Electrical heater (max) W WATER CONNECTIONS Type Gas Female Threaded Cooling coil inches 1/2" Heating coil inches 1/2" DIMEN- SIONS LxWxH mm 510x430x x430x x430x x430x x430x220 WEIGHT Unit weight kg (1) According to Eurovent standard: Air: 27 C DB/19 C WB, Water in: 7 C/12 C. (2) According to Eurovent standard: Air: 20 C, Water in: 50 C, same water flow as in cooling. (3) According to Eurovent standard: Air: 20 C, Water in: 70 C/60 C. (4) Sound pressure for console unit considering a local of 100 m ³, a reverberation time of 0,5 sec and a distance of 1 m. List of accessories is available page 26 and 27. Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +90 C 17 bars Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) 5 C/15% RH 32 C/70% RH 20 21

12 Fan coil units AquaFan AWC/AHC AWN/AHN FAN COIL UNIT ALL ELECTRICAL VERSION OFFICES AquaFan A20E A40E A60E Air flow (m3/h) Electrical heating capacicty (W) Total electrical consumption (W) HS m³/h MS m³/h LS m³/h HS W MS W LS W HS W MS W LS W Cooling Capacity: from 1,1 to 7,2 kw Versions: 3 models: A20E-A40E-A60E Configurations: Vertical console with cabinet Ceiling exposed with cabinet Vertical concealed without cabinet Ceiling concealed without cabinet 230 V / 1Ph / 50 Hz 400 V / 3Ph / 50 Hz Absorbed intensity (A) HS W 9,98 19,78 MS W 9,9 19,73 LS W 4,96 9,93 Fuse (gg) (A) Absorbed intensity (A) HS W 3,31 6,57 10,55 MS W 3,29 6,55 10,5 LS W 1,65 3,3 5,26 Fuse (gg) (A) Accessories for customization on site available - See pages 24 and 25. Product Avantages Ease of installation Harmonuous and aesthetic RAL9003 painted cabinet design Streamlined design and elaborate finish enabling harmonious integration 5-speed AC fan motor Very low operating acoustical levels Airflow rate between 140 and 1400 m3/h Electrical Aquafan II A20E A40E A60E Unit delivered with Aquanet control and RCL remote control. Price 2250 W 4500 W 7200 W 7VE VE VE Main Options 2-stage heater available with Aquanet control AC motor with 3 speeds pre-wired Aquanet control delivered in standard with the unit Main Accessories ModBus Communication interface board UBMS Control Front or bottom air intake configuration Motorized or manual fresh air damper 22 23

13 Fan coil units AccessorieS AquaFan II ACCESSORiES (supplied loose) MP Support feet for AWC Support feet for AWN MPG External Grillle for TMT BAC Auxiliary drain pan for AWC/AWN Auxiliary drain pan for AHC/AHN PRC Drain pan pump FA RVCA-RT RVCA-RC RVCM-RT RVCM-RC Plénum APS Plénum APSA External filter section for AHN when ducted at suction side Air intake arrangement with motorized (non controlled) on/off damper (back or/and front intake) Air intake arrangement with motorized (non controlled) on/off damper (floor or/and front intake) Air intake arrangement with manual damper (back or/and front intake) Air intake arrangement with manual damper (floor or/and front intake) Discharge plenum with duct 1 x 200 mm for AWN/AHN Discharge plenum with duct 1 x 250 mm Ob for AWN/AHN Discharge plenum with duct 2 x 200 mm for AWN/AHN Discharge plenum with duct 3 x 200 mm for AWN/AHN Discharge plenum with duct 3 x 250 mm Ob for AWN/AHN Return & Discharge plenum with duct 1 x 200 mm Return & Discharge plenum with duct 1 x 250 mm Ob Return & Discharge plenum with duct 2 x 200 mm Return & Discharge plenum with duct 3 x 200 mm Return & Discharge plenum with duct 3 x 250 mm Ob Kit code 7ACTL0391 7ACTL0391 7ACTL0391 7ACTL0391 7ACTL0391 7ACTL0391 7ACTL0391 Price kit Kit code 7ACTL0415 7ACTL0415 7ACTL0415 7ACTL0415 7ACTL0415 7ACTL0415 7ACTL0415 Price kit Kit code 7ACVF0330 7ACVF0331 7ACVF0332 7ACVF0333 7ACVF0334 7ACVF0333 7ACVF0334 Price kit Kit code 7ACTL0394 Price kit G = 7ACTL0448 Kit code G=7ACTL0446 D=7ACTL0445 D = 7ACTL Price kit n.a. Kit code AWC AWN 7ACFH0603 Kit code AHC AHN 7ACFH0631 7ACFH0632 G=7ACFH0635 D=7ACFH0634 Price kit Kit code 7ACTL0486 Price kit 8 Right Kit code 7ACVF0360 7ACVF0361 7ACVF0362 7ACVF0363 7ACVF0364 7ACVF0363 7ACVF0364 Left Kit code 7ACVF0366 7ACVF0367 7ACVF0368 7ACVF0369 7ACVF0370 7ACVF0369 7ACVF0370 Price kit Right Kit code 7ACVF0372 7ACVF0373 7ACVF0374 7ACVF0375 7ACVF0376 7ACVF0375 7ACVF0376 Left Kit code 7ACVF0378 7ACVF0379 7ACVF0380 7ACVF0381 7ACVF0382 7ACVF0381 7ACVF0382 Price kit Right Kit code 7ACVF0384 7ACVF0385 7ACVF0386 7ACVF0387 7ACVF0388 7ACVF0387 7ACVF0388 Left Kit code 7ACVF0390 7ACVF0391 7ACVF0392 7ACVF0393 7ACVF0394 7ACVF0393 7ACVF0394 Price kit Right Kit code 7ACVF0396 7ACVF0397 7ACVF0398 7ACVF0399 7ACVF0400 7ACVF0399 7ACVF0400 Left Kit code 7ACVF0402 7ACVF0403 7ACVF0404 7ACVF0405 7ACVF0406 7ACVF0405 7ACVF0406 Price kit Kit code 7ACVF0486 7ACVF Price kit n.a. n.a. n.a. n.a. n.a. Kit code - 7ACVF0488 7ACVF0489 7ACVF0491-7ACVF Price kit n.a n.a. 162 n.a. Kit code - - 7ACVF0490 7ACVF0492-7ACVF Price kit n.a. n.a n.a. 166 n.a. Kit code ACVF0493 7ACVF0495 7ACVF0493 Price kit n.a. n.a. n.a. n.a Kit code ACVF0494-7ACVF0494 Price kit n.a. n.a. n.a. n.a. 181 n.a. 181 Kit code 7ACVF0496 7ACVF Price kit n.a. n.a. n.a. n.a. n.a. Kit code - 7ACVF0498 7ACVF0499 7ACVF0501-7ACVF Price kit n.a n.a. 249 n.a. Kit code - - 7ACVF0500 7ACVF0502-7ACVF Price kit n.a. n.a n.a. 256 n.a. Kit code ACVF0503 7ACVF0505 7ACVF0503 Price kit n.a. n.a. n.a. n.a Kit code ACVF0504-7ACVF0504 Price kit n.a. n.a. n.a. n.a. 282 n.a. 282 CONTROL ACCESSORiES (supplied loose) CMV TBMV TRM-VP TRM-FA PCO AQS AQS OB Fan speed selector for mounting on unit Bulb thermostat with summer/winter manual switch for mounting on unit - action on control valve and fan Remote thermostat with summer/winter manual switch - action on control valve Remote thermostat with summer/winter manual switch - action on control valve and fan Mechanical sensor for automatique change over Régulateur Aquasimp pour montage Aquasimp controller for wall mounting Aquasimp controller for AWC mounting WPT AQS Water probe for Aquasimp TAE20+SEH Electronic thermostat TAE20 + change over sensor EH Relay Electrical heater relay for terminal Kit AQN AQN ACC NIU ENIU FCC controller all configurations supplied loose for Aquafan Aquanet accessories - 6 plugs + 4 jumpers + RCL connector µbms compatible communication board NIU for Aquanet Modbus communication board eniu for Aquanet mbms µbms supervisor RCL RCL remote control (supplied loose) IR Rec Wall IR receiver for Aquanet (Aquanet not included) On stock Right Kit code Left Kit code 7ACEL1454 7ACEL1453 Price kit 27 Right Kit code Left Kit code 7ACEL1431 7ACEL1430 Price kit 62 Kit code 7ACEL1444 Price kit 72 Kit code 7ACEL1441 Price kit 61 Kit code 7ACEL1473 Price kit 72 Kit code 7ACEL1546 Price kit 87 Kit code 7ACEL1532 Price kit 100 Kit code 7ACEL1547 Price kit 17 Kit code 7ACEL1452 Price kit 234 Kit code 7ACEL1465 Price kit 36 Kit code 7ACEL1432 Price kit 148 Kit code 7ACEL1492 Price kit 26 Kit code 7ACEL1462 Price kit 27 Kit code 7ACEL1463 Price kit 35 Kit code 7ACEL1449 Price kit 260 Kit code 7ACEL1446 Price kit 43 Kit code 7ACEL1364 Price kit

14 Fan coil units 230 V Thermal Type ON/OFF Valve AWC AWN AHC AHN 2-way type, one valve for one coil - W2G1 2-way type, two valves for two coils - W2G2 2-way type, two valves for two coils - W2G2 4-way type, two valves for two coils - W4G2 2-way type, one valve for one coil - W2G1 2-way type, two valves for two coils - W2G2 4-way type, one valve for one coil - W4G1 4-way type, two valves for two coils - W4G2 Kit code 7ACFH0555 7ACFH0579 Price kit Kit code 7ACFH0558 7ACFH0582 Price kit Kit code 7ACFH0561 7ACFH0585 Price kit Kit code 7ACFH0564 7ACFH0588 Price kit Left kit code 7ACFH0556 7ACFH0580 Right kit code 7ACFH0557 7ACFH0581 Price kit Left kit code 7ACFH0559 7ACFH0583 Right kit code 7ACFH0560 7ACFH0584 Price kit Left kit code 7ACFH0562 7ACFH0586 Right kit code 7ACFH0563 7ACFH0587 Price kit Left kit code 7ACFH0565 7ACFH0589 Right kit code 7ACFH0566 7ACFH0590 Price kit ELECTRICAL HEATER (Supplied loose) Inserted into coil Configuration must to be defined in accordance with mounted fan coil 300w n.a. n.a. n.a. n.a. n.a. 500w n.a. n.a. 341 n.a. n.a. n.a. n.a. 600w n.a. 347 n.a. n.a. n.a. 750w n.a. n.a. n.a. n.a n.a. 900w n.a. n.a. n.a. n.a. n.a. 1000w n.a. n.a. 305 n.a. n.a. n.a. n.a. 1200w n.a. 336 n.a. 310 n.a. n.a. n.a. 1500w n.a. n.a. 383 n.a n.a. 1800w n.a. n.a. n.a. 392 n.a. n.a. n.a. 2000w n.a. n.a. 352 n.a. n.a. n.a. n.a. 2250w n.a. n.a. n.a. n.a n.a. 2400w n.a. n.a. n.a. 358 n.a. n.a. n.a. 3000w n.a. n.a. n.a. n.a n.a. On stock 26 27

15 Chilled water cassette WKW LN STD 4-way chilled water cassette cooling and heating WKW Size 09 LN 12 LN 18 LN 30 LN 45 LN CapacitIEs - 2 PIPE Nominal Total cooling capacity W 1600 / 1900 / / 2600 / / 3700 / /5740/ /7039/9298 Sensible capacity W 1250 / 1500 / / 2050 / / 2950 / /4394/ /5728/7650 Cooling (1) Water flow l/h 280 / 330 / / 450 / / 640 / /989/ /1212/1602 Water pressure drop kpa 6 / 9 / 12 8 / 11 / 18 8/11/16 7,5/13,5/19,6 8,0/12,5/20,0 Heating (2) Heating capacity W 2100 / 2500 / / 3200 / / 4600 / /7486/ /8842/11716 CapacitIEs - 4 PIPE Nominal Cooling Capacity: from 2,3 to 10,2 kw Heating Capacity: from 2,2 to 11,6 kw Sizes : 5 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Cassette Product Avantages designed for suspended ceiling integration. 600x600 (9, 12 and 18 models) and 600x1200 formats, (30 and 45 models). Low built-in height: 287 mm. direct access to electrical connection on sliding chassis. integrated valve and electrical connections. 3-speed AC fan motor. Very low operating acoustical levels with new low noise LN versions (9, 12 and 18 models). Coil with hydrophilic fins to improve the condensate flow. fresh air intake. Air distribution in adjacent room. integrated condensate drain lift pump up to 600 mm, (3-top for 9, 12 and 18 models). infra-red remote control version with valve and change-over. galvanized steel sheet with thermal and acoustical insulation, avoiding condensation on the casing and providing good sound attenuation. Possibility to close one or two discharge flaps. Cleanable synthetic-type air filter. Minimum water temperature Maximum water temperature Maximum operating pressure Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) HOTEL HOSPITAL Operating limit for Standard unit Main Options Electrical heater with inserted heating rod. 2-stage heater available with Aquanet control. AC motor. Selection of 3 speed. Large choice of control: Aquanet control or wall-mounted thermostat. 2-way or 3-way ON/OFF valve. G1 filter. Condensate drain pump. Relay. Fuse holder. ModBus Communication interface board. Design metallic panel with 192 colours and Coanda air diffusion ( models). Main Accessories Valve. Aquanet control. Solid ceiling frame. Condensate drain pump. Auxiliary condensate drain pan. Master and slaves control, up to 4 units max. Selection Software Select It. +5 C +70 C (size ) +60 C (size 30/45) 15 bars 13 C/15% RH 32 C/70% RH Total cooling capacity W 1600 / 1900 / / 2600 / / 3700 / /7925/9887 Sensible capacity W 1250 / 1500 / / 2050 / / 2950 / /6185/7655 Cooling (1) Water flow l/h 280 / 330 / / 450 / / 640 / /1365/1703 Water pressure drop kpa 6 / 9 / 12 8 / 11 / 18 8 / 11 / 16-10,5/18,5/28 Heating (3) Water flow l/h 160 / 180 / / 220 / / 340 / /658/788 Heating capacity W 1700 / 1900 / / 2500 / / 3950 / /7506/8980 Water pressure drop kpa ,0/6,0/8,0 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 34/40/50 34/40/50 41/49/57 37,5/46,4/55,2 46,3/53,7/61,6 Sound pressure level db(a) (4) 26/32/42 26/32/42 33/41/49 31,9/40,6/49,3 40,7/48,1/55,6 NR (4) db(a) 20/27/37 20/27/37 28/35/43 29/36/44 35/42/50 FANS (LS/MS/HS) Number Airflow m³/h 330/450/ /450/ /580/ /905/ /1080/1560 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230/1/50 Fan consumption - STD W 20/30/50 20/30/50 21/30/46/71 165/180/ /170/180 Electrical heater W WATER CONNECTIONS Type Gas male threaded Cooling coil inches 20/30/50 20/30/50 30/46/71 38/66/100 63/91/140 Heating coil inches DIMENSIONS Casing (LxWxH) mm 571 x 571 x x 571 x 287 Grille (LxWxH) mm 625 x 625 x x 625 x 40 WEIGHT Unit weight kg (1) According to Eurovent standard: Air: 27 C DB/19 C WB, Water in: 7 C/12 C. (2) According to Eurovent standard: Air: 20 C, Water in: 50 C, same water flow as in cooling. (3) Air: 20 C, Water in: 60 C/50 C. (4) Sound pressure considering a local of 100 m ³, a reverberation time of 0,5 sec and a distance of 1 m. NEW: on stock! Configuration: 2 or 4-pipes, terminal block or IR, with or without 3-way valve, no brand. PRODUCT CODEs 09 LN 12 LN 18 LN 30 LN 45 LN 2 Pipe without valve WKW 9 OG 2T SV WKW 12 OG 2T SV WKW 18 OG 2T SV WKW 30 OG 2T SV WKW 45 OG 2T SV 7OG OG OG SP SP Price WKW 9 OG 2T AV WKW 12 OG 2T AV WKW 18 OG 2T AV 2Pipe with 3-w valve 7OG OG OG Price WKW 9 OG 2T IR AV WKW 12 OG 2T IR AV WKW 18 OG 2T IR AV 2Pipe IR with 3-w valve 7OG OG OG Price WKW 9 OG 4T SV WKW 12 OG 4T SV WKW 18 OG 4T SV 4Pipe without valve 7OG OG OG Price WKW 9 OG 4T AV WKW 12 OG 4T AV WKW 18 OG 4T AV 4Pipe with 3-w valve 7OG OG OG Price On stock 28 29

16 Chilled water cassette WKW LN EC 4-way chilled water cassette cooling and heating Cooling Capacity: from 2,2 to 4,6 kw Heating Capacity: from 2,0 to 5,7 kw Sizes : 3 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Cassette Product Avantages HOTEL HOSPITAL designed for suspended ceiling integration 600x600 mm. Low built-in height: 287 mm. direct access to electrical connection on sliding chassis. integrated valve and electrical connections. Low consumption EC fan motor. Very low operating acoustical levels with new low noise LN versions. Coil with hydrophilic fins to improve the condensate flow. fresh air intake. Air distribution in adjacent room. integrated 3-top condensate drain lift pump up to 600 mm. infra-red remote control version with valve and change-over. galvanized steel sheet with thermal and acoustical insulation, avoiding condensation on the casing and providing good sound attenuation. Possibility to close one or two discharge flaps. Cleanable synthetic-type air filter. Main Options Electrical heater with inserted heating rod. 2-stage heater available with Aquanet control. EC motor. Selection of 3 speed with ECoSpeed3 board. Large choice of control: Aquanet control or wall-mounted thermostat. 2-way or 3-way ON/OFF valve. G1 filter. Condensate drain pump. Relay. Fuse holder. ModBus Communication interface board. Design metallic panel with 192 colours and Coanda air diffusion ( models). Main Accessories Valve. Aquanet control. Solid ceiling frame. Condensate drain pump. Auxiliary condensate drain pan. Selection Software Select It. WKW Size 09 LN 12 LN 18 LN Capacities - 2 PIPE NOMINAL Total cooling capacity W 1600 / 1900 / / 2600 / / 3700 / 4600 Sensible capacity W 1250 / 1500 / / 2050 / / 2950 / 3850 Cooling (1) Water flow l/h 280 / 330 / / 450 / / 640 / 790 Water pressure drop kpa 6 / 9 / 12 8 / 11 / Heating (2) Heating capacity W 2100 / 2500 / / 3200 / / 4600 / 5700 Capacities - 4 PIPE NOMINAL Total cooling capacity W 1600 / 1900 / / 2600 / / 3700 / 4600 Sensible capacity W 1250 / 1500 / / 2050 / / 2950 / 3850 Cooling (1) Water flow l/h 280 / 330 / / 450 / / 640 / 790 Water pressure drop kpa 6 / 9 / 12 8 / 11 / 18 8 / 11 / 16 Heating (3) Water flow l/h 160 / 180 / / 220 / / 340 / 380 Heating capacity W 1700 / 1900 / / 2500 / / 3950 / 4470 Water pressure drop kpa 3 / 4 / 5 7 / 9 / SOUND LEVELS (LS/MS/HS) Sound power level db(a) 34 / 40 / / 40 / 50 41/49/57 Sound pressure level (4) db(a) 26 / 32 / / 32 / 42 33/41/49 NR (4) db(a) 20 / 27 / / 27 / 37 28/35/43 FANS (LS/MS/HS) Number Airflow m³/h 330 / 450 / / 450 / / 580 / 830 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230 / 1 / 50 WATER CONNECTIONS DIMENSIONS WEIGHT Absorbed power W 8 / 11 / 26 8 / 11 / 26 9 / 23 / 41 Electrical heater (max) W Type Gas male threaded Cooling coil inches 1/2" 1/2" 3/4" Heating coil inches 1/2" 1/2" 1/2" Casing (LxWxH) mm 571x571x287 Grille (LxWxH) mm 625x625x40 Unit weight kg (1) According to Eurovent standard: Air: 27 C DB/19 C WB, Water in: 7 C/12 C. (2) According to Eurovent standard: Air: 20 C, Water in: 50 C, same water flow as in cooling. (3) Air: 20 C, Water in: 60 C/50 C. (4) Sound pressure considering a local of 100 m ³, a reverberation time of 0,5 sec and a distance of 1 m. Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +70 C (size ) +60 C (size 30/45) 15 bars Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) 13 C/15% RH 32 C/70% RH 30 31

17 Chilled water cassette AccessorIes WKW ACCESSORY CODE 09 LN 12 LN 18 LN 30 LN 45LN 3-w valve + condensate tray - 2P 3-w valve + condensate tray - 2P 3-w valve + condensate tray - 4P 3-w valve + condensate tray - 2P Drain Pan - 2P Aux drain pan Drain Pan - 4P Aux drain pan Special frame for solid ceiling Special frame for solid ceiling ACFH0051 7ACFH0052 Price ACFH0122 Price ACTL0083 7ACTL0005 7ACTL0005 Price ACTL0083-7ACTL0040 Price ACVF0091A - - Prix ACCESSORY REGULATION 09 LN 12 LN 18 LN 30 LN 45LN TRM-VP TRM-FA Remote thermostat with summer/winter manual switch - action on control valve Remote thermostat with summer/winter manual switch - action on control valve and fan Aquanet Aquanet control RCL NIU eniu RCL remote control (supplied loose) µbms compatible communication board NIU for Aquanet Modbus communication board eniu for Aquanet µbms µbms supervisor Aquasimp Aquasimp controller for wall mounting WPT pour Aquasimp Water probe for Aquasimp TAE20+SEH Electronic thermostat TAE20 + change over sensor Relay kit M/S relay kit 7ACEL1444 Price 72 7ACEL1441 Price 61 7ACEL1432 Price 148 7ACEL1446 Price 43 7ACEL1462 Price 27 7ACEL1463 Price 36 7ACEL1449 Price 260 7ACEL1546 Price 87 7ACEL1547 Price 16 7ACEL1452 Price 234 7ACEL1207 Price

18 Chilled water cassette KCO2 1-WAY CHILLED WATER CASSETTE COANDA effect Cooling Capacity: from 1,1 kw to 3,3 kw Heating Capacity: from 1,3 kw to 3,4 kw Sizes : 3 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Cassette Product Avantages Innovative technical solution for architectural installations Advance aesthetic and harmonious design Designed for suspended ceiling installation Possible gravity condensate evacuation Optimum coanda effect through uniform airflow Adjustable multidirectionnal diffusers with high induction 5 speed AC fan motor Very low acoustic levels Galvanized steel sheet with acoustical insulation Air filtration HOSPITAL NEW Main Options Electrical heater On-board electronic control Aquanet or terminal block for wall-mounted control ModBus Communication interface board 2-way or 3-way ON/OFF valve Fresh air intake Condensate drain pump Selection Software Select KCO2. KCO2 Size Capacities - 2 PIPE (LS/MS/HS) Total cooling capacity W 880 / 1060 / / 1620 / / 2840 / 3340 Sensible capacity W 660 / 810 / / 1190 / / 2110 / 2510 Cooling (1) Water flow l/h 163 / 196 / / 299 / / 525 / 617 Water pressure drop kpa 2,4 / 3,3 / 6,1 2,9 / 3,9 / 7,6 6,4 / 12,1 / 16,2 Heating (2) Heating capacity W 1080 / 1330 / / 1910 / / 3370 / 4020 Capacities - 4 PIPE (LS/MS/HS) Total cooling capacity W 880 / 1060 / / 1620 / / 2840 / 3340 Sensible capacity W 660 / 810 / / 1190 / / 2110 / 2510 Cooling (1) Water flow l/h 163 / 196 / / 299 / / 525 / 617 Water pressure drop kpa 2,4 / 3,3 / 6,1 2,9 / 3,9 / 7,6 6,4 / 12,1 / 16,2 Heating (3) Water flow l/h 79 / 93 / / 147 / / 247 / 284 Heating capacity W 920 / 1080 / / 1710 / / 2870 / 3300 Water pressure drop kpa 1,6 / 2,1 / 3,6 0,9 / 1,2 / 2,0 2,0 / 3,4 / 4,3 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 35/41/52 33/36/48 35/46/52 Sound pressure level (4) db(a) 26/32/43 24/27/39 26/37/43 NR (4) db(a) 22/28/39 20/23/35 22/33/39 FANS (LS/MS/HS) Airflow m³/h 140 / 180 / / 240 / / 440 / 540 ELECTRICAL (LS/MS/HS) Power supply V / Ph / Hz 230 / 1 / 50 Fan consumption - STD W 16/22/49 24/27/44 27/42/59 Electrical heater W WATER CONNECTIONS Type Gas male threaded Cooling coil inches 1/2" 1/2" 1/2" Heating coil inches 1/2" 1/2" 1/2" DIMENSIONS Casing (LxWxH) mm 592 x 592 x x 970 x x 1192 x 309 (1) According to Eurovent standard: Air : 27 C BS / 19 C BH, Eau : 7 C/12 C (2) According to Eurovent standard: Air : 20 C, Eau : 70 C/60 C. (3) Sound pressure considering a local attenuation of 9 db for a volume of 100m3 with a reverberation time of 0,5 sec. KCO2 KCO2 60 KCO2 90 KCO2 120 False ceiling integration Orientable diffusor with Coanda effect 7OG AW 7OG AW 7OG AW 2 Pipes Price OG AW 7OG AW 7OG AW 4 Pipes Price Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +80 C 10 bars 34 35

19 Chilled water cassette KCO2 EC 1-WAY CHILLED WATER CASSETTE COANDA effect Cooling Capacity: from 0,8 kw to 3,8 kw Heating Capacity: from 1 kw to 4,5 kw Sizes : 3 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Cassette Product Avantages EC motor with very low consumption Innovative technical solution for architectural installations Advance aesthetic and harmonious design Designed for suspended ceiling installation Possible gravity condensate evacuation Optimum coanda effect through uniform airflow Adjustable multidirectionnal diffusers High induction diffusion grille Very low acoustic levels Galvanized steel sheet with acoustical insulation HOSPITAL NEW Main Options EC motor Electrical heater On-board electronic control Aquanet or terminal block for wall-mounted control ModBus Communication interface board 2-way or 3-way ON/OFF valve Fresh air intake Condensate drain pump Selection Software Select KCO2. KCO2 EC Size Capacities - 2 PIPE Capacities - 4 PIPE Cooling (1) (LS/MS/HS) Total cooling capacity W 890 / 1180 / / 2310 / / 2780 / 3750 Sensible capacity W 620 / 910 / / 1730 / / 2060 / 2830 Water flow l/h 153 / 218 / / 428 / / 514 / 693 Water pressure drop kpa 2,1 / 4,0 / 6,5 3,2 / 7,3 / 12,6 5,8 / 11,7 / 19,8 Heating (2) Heating capacity W 1020 / 1500 / / 2790 / / 3300 / 4540 Cooling (1) (LS/MS/HS) Total cooling capacity W 8920 / 1180 / / 2310 / / 2780 / 3750 Sensible capacity W 620 / 910 / / 1730 / / 2060 / 2830 Water flow l/h 153 / 218 / / 428 / / 514 / 693 Water pressure drop kpa 2,1 / 4,0 / 6,5 3,2 / 7,3 / 12,6 5,8 / 11,7 / 19,8 Heating (3) Water flow l/h 75 / 101 / / 199 / / 243 / 313 Heating capacity W 870 / 1180 / / 2310 / / 2820 / 3640 SOUND LEVELS (LS/MS/HS) FANS (LS/MS/HS) ELECTRICAL WATER CONNECTIONS DIMENSIONS (LS/MS/HS) Water pressure drop kpa 1,4 / 2,5 / 3,8 1,0 / 2,0 / 3,1 1,8 / 3,3 / 5,1 Sound power level db(a) 35/46/55 34/46/56 36/48/58 Sound pressure level (4) db(a) 26/37/46 25/37/47 27/39/49 NR (4) db(a) 22/33/42 21/33/43 23/35/45 Airflow m³/h 130 / 205 / / 370 / / 430 / 620 Power supply V / Ph / Hz 230 / 1 / 50 Absorbed power W 8/14/29 34/46/56 36/48/58 Electrical heater W Type male pas gaz Cooling coil inches 1/2" 1/2" 1/2" Heating coil inches 1/2" 1/2" 1/2" Casing (LxWxH) mm 592 x 592 x x 970 x x 1192 x 309 1) According to Eurovent standard: Air : 27 C BS / 19 C BH, Eau : 7 C/12 C (2) According to Eurovent standard: Air : 20 C, Eau : 70 C/60 C. (3) Sound pressure considering a local attenuation of 9 db for a volume of 100m3 with a reverberation time of 0,5 sec. KCO2 KCO2 60 EC KCO2 90 EC KCO2 120 EC False ceiling integration Orientable diffusor with Coanda effect 7OG AW 7OG AW 7OG AW 2 Pipes Price OG AW 7OG AW 7OG AW 4 Pipes Price Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +80 C 10 bars 36 37

20 Hight wall chilled water units HaWair High wall chilled water unit Cooling and heating Cooling Capacity: from 2,2 to 4,7 kw Heating Capacity: from 2,0 to 5,9 kw Sizes : 4 Versions: 2-Pipes Configurations: High Wall Product Avantages Aesthetic design suitable for home and hotel applications. Silent unit for optimum customer comfort. Version with Integrated 3-way valve and IR control. Choice between IR or wall-mounted thermostat. Coil with hydrophilic fins to improve the condensate flow. Light unit for easy installation. Very easy servicing through removable front plate. Cleanable synthetic-type air filter. indoor unit compatible with all Airwell chilled water production units. Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) HOTEL +5 C +60 C 15 bars 6 C/15% RH 32 C/70% RH Main Options RC-08A IR control. Terminal block for wall-mounted thermostat. Version with 3-way ON/OFF valve. 3-speed tangential fan motor. Motorized flap. Electro-static anti-bacteria filter. Pipe connectors. Drilling template Main Accessories Valve. Aquanet control. Wall-mounted thermostat. HaWair Size HAW007 HAW009 HWA012 HAW022 CapacitIEs NOMINAL Total cooling capacity W 1650 / 1900 / / 2000 / / 3300 / / 4000 / 4700 Cooling (1) Sensible capacity W 1400 / 1640 / / 1700 / / 2650 / / 3300 / 3700 Water flow l/h 290 / 320 / / 360 / / 560 / / 690 / 810 Water pressure drop kpa 3 / 6 / 10 5 / 10 / / 27 / / 36 / 50 Heating (2) Heating capacity W 2000 / 2300 / / 2350 / / 4300 / / 4900 / 5850 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 36/40/44 38/42/48 45/48/52 50/54/58 Sound pressure level (4) db(a) 24/32/36 30/34/40 37/40/44 42/46/50 NR (4) db(a) 19/27/31 25/29/35 32/35/39/ 37/41/45 FANs (LS/MS/HS) Number Airflow m³/h 320/380/ /500/ /650/ /750/900 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230/1/50 Fan consumption W 22/26/28 22/26/28 25/28/31 43/47/58 WATER CONNECTIONS Type Femelle pas gaz Coil inches 1/2" 1/2" 1/2" 1/2" DIMENSIONS Casing (LxWxH) mm 845 x 275 x x 298 x 200 WEIGHT Unit weight (1) According to Eurovent standard: Air: 27 C DB/19 C WB, Water in: 7 C/12 C. (2) According to Eurovent standard: Air: 20 C, Water in: 50 C, same water flow as in cooling. (3) Sound pressure considering a local of 100m³, a reverberation time of 0,5 sec and a distance of 1 m. PRODUCT CODES HaWair 7 IR SV HaWair 9 IR SV HaWair 18 IR SV HaWair 22 IR SV 2 Pipes IR Without valve AWFC-HAW007-A AWFC-HAW009-A AWFC-HAW018-A AWFC-HAW022-A Price HaWair 9 IR AV - HaWair 22 IR AV 2 Pipes IR With valve - AWFC-HAW009-B - AWFC-HAW022-B Price HaWair 7 TB SV HaWair 9 TB SV HaWair 18 TB SV HaWair 22 TB SV 2 Pipes Without valve AWFC-HAW007-C AWFC-HAW009-C AWFC-HAW018-C AWFC-HAW022-C Price ACCESSORY CODES TRM-VP Remote thermostat with 7ACEL1444 summer/winter manual switch - action on control valve Price 72 TRM-FA Remote thermostat with summer/winter manual switch - 7ACEL1441 action on control valve and fan Price 61 PCO Mechanical sensor for automatique change over Aquanet Aquanet control - remote RCL NIU eniu µbms Aquasimp RCL remote control (supplied loose) µbms compatible communication board NIU for Aquanet Modbus communication board eniu for Aquanet µbms supervisor Aquasimp controller for wall mounting WPT pour Aquasimp Water probe for Aquasimp TAE20 TAE20+SEH SEH W261 W461 Electronic thermostat TAE20 Electronic thermostat TAE20 + change over sensor SChange over sensor for TAE 20 1 valve 2-Pipes 2V/TOR/2T 1 valve 3-Pipes 4V/TOR/2T 7ACEL1473 Price 71 7ACEL1432 Price HT 148 7ACEL1446 Price 43 7ACEL1462 Price 27 7ACEL1463 Price 36 7ACEL1449 Price 260 7ACEL1546 Price 87 7ACEL1547 Price 17 7ACEL1451 Price 193 7ACEL1452 Prix 234 7ACEL1233 Price 47 7ACFH0814 Prix 92 7ACFH0815 Price

21 Pressure ductable fan coil unit DUCTYS PRESSURE DUCTABLE FAN COIL UNIT COOLING AND HEATING Cooling Capacity: from 1,2 to 3,3 kw Heating Capacity: from 1,6 to 4,0 kw Sizes : 3 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Ceiling concealed Product Avantages Blue fin coil OFFICES EC fan motor with very low consumption. Very low height (223 mm). Ease of installation and maintenance. In-line or same side (U-type) airflow diffusion. Static pressure available up to 100 Pa. Very low operating acoustical levels. Selection of hydraulic and electric service side. Configuration flexibility thanks to modular conception. Various air intake and discharge configuration: rectangular or duct connections. Coil with hydrophilic fins to improve the condensate flow. Extended monobloc condensate drain pan. Pipe locking system. High outlet temperature for an optimal confort. Many aeraulic configurations Operating limit for Standard unit NEW Conçus & fabriqués en Designed & produced in depuis 1947 Main Options FRANCE Electrical heater with inserted heating rod On-board electronic control or terminal block for wall-mounted control ModBus Communication interface board 2-way or 3-way ON/OFF valve Ducted or rectangular plenum for air intake or dischage Fresh air intake Condensate drain pump G2 filter Fuse holder Main Accessories 2-way or 3-way ON/OFF valve Large choice of controls : Electro-mechanic, electronic, on-board or wall-mounted IR control Suspension kit Selection Software Select It. DUCTYS Size Ductys 1500 Ductys 2000 Ductys 2500 CAPACITIES - 2 PIPE CAPACITIES - 4 PIPE Cooling (1) (LS/MS/HS) Total cooling capacity W 1230 / 1700 / / 2230 / / 2810 / 3260 Sensible capacity W 1130 / 1540 / / 1950 / / 2280 / 2690 Available static pressure Pa 19 / 50 / / 50 / / 50 / 66 Water flow l/h 210 / 290 / / 380 / / 480 / 565 Water pressure drop kpa 4 / 7 / 9 8 / 13 / / 21 / 28 Heating (2) Heating capacity W 1600 / 2260 / / 2930 / / 3600 / 4020 Cooling (1) Heating (3) (LS/MS/HS) SOUND LEVELS (LS/MS/HS) FAN (LS/MS/HS) ELECTRICAL ELECTRICAL CLASS WATER CONNECTIONS DIMENSIONS POIDS Total cooling capacity W 1190 / 1610 / / 2190 / / 2730 / 3010 Sensible capacity W 1080 / 1470 / / 1930 / / 2200 / 2460 Available static pressure Pa 18 / 50 / / 50 / / 50 / 55 Water flow l/h 205 / 280 / / 380 / / 470 / 520 Water pressure drop kpa 4 / 7 / 9 8 / 13 / / 20 / 23 Heating capacity W 2230 / 2850 / / 3460 / / 4220 / 4540 Water flow l/h 190 / 250 / / 300 / / 365 / 390 Water pressure drop kpa 6 / 9 / / 16 / / 21 / 24 Sound power level Ret + Rad (4) db(a) 44 / 52 / / 57 / / 55 / 61 (LS/MS/HS) Sound power level Dis (4) db(a) 45 / 56 / / 57 / / 56 / 61 Sound pressure level (5) db(a) 26 / 35 / / 36 / / 36 / 43 NR (5) 21 / 30 / / 31 / / 31 / 38 Number Airflow 2-Pipes m³/h 270 / 400 / / 520 / / 550 / 640 Airflow 4-Pipes m³/h 265 / 380 / / 510 / / 525 / 595 Power supply V / Ph / Hz 230 / 1 / Fan consumption W 8 / 30 / / 47 / / 41 / 64 Fan setpoint V 3.8 / 6.0 / / 7.1 / / 3.9 / 4.9 Electrical heater W 600 / / / Pipes FCEER B B B FCCOP A A A 4-Pipes FCEER B B B FCCOP A A A Type Femelle pas Gaz Cooling coil inches 1/2" 1/2" 1/2" Heating coil inches 1/2" 1/2" 1/2" Casing (LxWxH) mm 581 x 640 x x 740 x x 840 x 223 kg Minimum water temperature Maximum water temperature Maximum operating pressure Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) +5 C +60 C 15 bars 5 C/15% RH 32 C/70% RH Performances based on: (1) According to Eurovent standard: Air: 27 C DB / 19 C WB, Water: 7 C/12 C, 50 Pa external static pressure in medium speed. (2) According to Eurovent standard: Air: 20 C, same water flow as in cooling, 50 Pa external static pressure in medium speed. (3) According to Eurovent standard: Air: 20 C, Water: 70 C/60 C, 50 Pa external static pressure in medium speed. (4) According Eurovent standard: Return + radiated / Discharge sound power level given for a unit with 50 Pa external static pressure in medium speed. (5) Sound pressure considering an hypothetical installation and local attenuation of 21 db. Configuration return / discharge: rectangular - rectangular According to Eurovent standard 6/9 (thermal), 6/10 (airflow) et 8/12 (acoustics) 40 41

22 Pressure ductable fan coil unit VH STD High static pressure ductable fan coil unit COOLING AND HEATING VH STD Size CapacitIEs - 2 PIPE - Nominal AT 50 Pa Cooling (1) Total cooling capacity W 4560/5500/ /11930/ /14430/ /16130/ /17240/ /19400/22640 Sensible capacity W 3270/4150/ /9610/ /10840/ /11690/ /12790/ /13780/16240 Water flow l/h 785/950/ /2055/ /2486/ /2778/ /2970/ /3342/3900 Water pressure drop kpa 27/39/45 8/20/26 7/20/28 8/29/43 13/17/21 14/18/23 Heating (2) Heating capacity W 5370/7060/ /14870/ /17050/ /18110/ /21620/ /22290/26370 CapacitIEs - 4 PIPE - Nominal AT 50 Pa Total cooling capacity W 4180/5020/ /10460/ /11570/ /14760/ /15790/ /17300/19790 Cooling (1) Sensible capacity W 2990/3740/ /8840/ /9540/ /10970/ /12160/ /12800/14910 Water flow l/h 720/865/ /1800/ /1993/ /2540/ /2720/ /2980/3410 Water pressure drop kpa 20/27/30 6/13/17 7/17/23 11/35/51 15/19/23 13/17/21 Heating (3) Water flow l/h 725/920/ /2360/ /2360/ /2360/ /2900/ /2900/3310 Heating capacity W 5890/7470/ /19190/ /19190/ /19190/ /23600/ /23590/26920 Water pressure drop kpa 9/14/16 39/109/156 24/66/95 24/66/95 74/93/118 46/58/75 FACTORY SOUND LEVELS (LS/MS/HS) Cooling Capacity: from 2,1 kw to 28,4 kw Heating Capacity: from 3,5 kw to 33,9 kw Sizes : 6 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Ceiling concealed Product Avantages Ease of installation and maintenance. High static pressure avaiable up to 200 Pa. Airflow rate up to 4650 m³/h. Energy saving EC fan motor. Very low operating acoustical levels in low speeds. Selection of hydraulic and electric service side. Configuration flexibility thanks to modular conception. Various air intake configuration: rectangular or duct connections. Coil with hydrophilic fins to improve the condensate flow. g3 filter as standard. Compliant with ERP directive. Main Options Electrical heater with inserted heating rod. 2-stage heater available with Aquanet control. Selection of 3 speed. Large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus Communication interface board. 2-way or 3-way ON/OFF valve. G4 filter in option. Ducted or rectangular plenum for air intake or dischage. Fresh air intake. Double skin insulation for ERP applications. Auxiliary condensate drain pan. Condensate drain pump. Relay. Fuse holder. Individual packaging. Main Accessories Valve. Control. IR control. Drain pan. Condensate drain pump. Choice of ducted plenum for air intake or dischage. Selection Software Select It. FANS ELECTRICAL Sound power level (4) db(a) 54/60/63 52/65/72 52/65/72 52/65/72 65/69/72 65/69/72 Sound pressure level (5) db(a) 53/59/61 52/64/71 52/64/71 52/64/71 63/67/71 63/67/71 Sound pressure level (5) db(a) 33/39/42 31/44/51 31/44/51 31/44/51 44/48/54 44/48/54 NR (5) db(a) 27/34/37 27/40/47 27/40/47 27/40/47 40/44/51 40/44/51 (LS/MS/HS) Number Static pressure kpa 30/50/70 15/50/90 15/50/90 15/50/90 35/50/75 35/50/75 Airflow at 50 Pa m³/h 703/977/ /2112/ /2112/ /2112/ /2413/ /2413/2925 (LS/MS/HS) Power supply V/Ph/Hz 230 / Fan consumption STD W 132/182/ /421/ /421/ /421/ /530/ /530/870 Electrical heater (max) W WATER CONNECTIONS DIMENSIONS Type Femelle pas gaz Mâle pas gaz Cooling coil 2-Pipes inches 1/2" 1" 1 1/4" 1 1/4" 1 1/4" 1 1/4" Cooling coil 4-Pipes inches 1/2" 1" 1" 1" 1 1/4" 1 1/4" Heating coil inches 1/2" 3/4" 3/4" 3/4" 3/4" 3/4" Rect-rect LxWxH mm 698 x 1200 x x 1380 x x 1380 x x 1380 x x 1500 x x 1500 x 450 Circ-Circ LxWxH mm 1014 x 1200 x WEIGHT Rect-rect Unit weight kg Circ-circ Unit weight kg (1) Air: 27 C DB/19 C WB, Water in: 7 C/12 C, 50 Pa external static pressure. (2) Air: 20 C, Water in: 50 C, same water flow as in cooling, 50 Pa external static pressure. (3) Air: 20 C, Water in: 70 C/60 C, 50 Pa external static pressure. (4) According Eurovent standard: Return + radiated sound power level given for a unit with 50 Pa external static pressure in medium speed. (5) Sound pressure considering an hypothetical installation and local attenuation of 21 db. Operating limit for Standard unit Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +60 C 15 bars Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) 5 C/15% RH 32 C/70% RH 42 43

23 Pressure ductable fan coil unit VH EC High static pressure ductable fan coil unit COOLING AND HEATING Cooling Capacity: 5,5 kw Heating Capacity: 4,2 kw Sizes : 1 Versions: 2-Pipes 2-Pipes/2-Wires 4-Pipes Configurations: Ceiling concealed Product Avantages FACTORY Ease of installation and maintenance. High static pressure avaiable up to 200 Pa. Airflow rate up to 4650 m³/h. Energy saving EC fan motor. Very low operating acoustical levels in low speeds. Selection of hydraulic and electric service side. Configuration flexibility thanks to modular conception. Various air intake configuration: rectangular or duct connections. Coil with hydrophilic fins to improve the condensate flow. g3 filter as standard. Compliant with ERP directive. Operating limit for Standard unit Conçus & fabriqués en Designed & produced in depuis 1947 Main Options Electrical heater with inserted heating rod. 2-stage heater available with Aquanet control. Selection of 3 speed. EC motor. Large choice of control: Electro-mechanic, electronic, on-board or wall-mounted. ModBus Communication interface board. 2-way or 3-way ON/OFF valve. G4 filter in option. Ducted or rectangular plenum for air intake or dischage. Fresh air intake. Double skin insulation for ERP applications. Auxiliary condensate drain pan. Condensate drain pump. Relay. Fuse holder. Individual packaging. Main Accessories Valve. Control. IR control. Drain pan. Condensate drain pump. Choice of ducted plenum for air intake or dischage.. Selection Software Select It. FRANCE VH EC Size 07 CapacitIEs - 2 PIPE Nominal AT 50 Pa Total cooling capacity W 4560 / 5500 / 5810 Cooling (1) Sensible capacity W 3270 / 4150 / 4470 Water flow l/h 785 / 950 / 1000 Water pressure drop kpa 27 / 39 / 45 Heating (2) Heating capacity W 5370 / 7060 / 7630 CapacitIEs - 4 PIPE Nominal AT 50 Pa Total cooling capacity W 4180 / 5020 / 5300 Cooling (1) Sensible capacity W 2990 / 3740 / 4020 Water flow l/h 720 / 865 / 913 Water pressure drop kpa 20 / 27 / 30 Heating (3) Water flow l/h 725 / 920 / 990 Heating capacity W 5890 / 7470 / 8050 Water pressure drop kpa 9 / 14 / 16 SOUND LEVELS (LS/MS/HS) Sound power acoustic Aspiration+Ray db(a) 54 / 60 / 63 Sound power level (4) db(a) 53 / 59 / 61 Sound pressure level (5) db(a) 33 / 39 / 42 NR (5) db(a) 27 / 34 / 37 FANS (LS/MS/HS) Number 2 Static pressure Pa 30 /50 / 70 Airflow at 50 Pa m³/h 703 /977 / 1125 ELECTRICAL (LS/MS/HS) Power supply V/Ph/Hz 230 / 1 / Fan consumption W 40 / 90 / 121 Set voltage V 3,5 / 6 / 8,9 Electrical heater (max) W 2000 WATER CONNECTIONS Type Gas female threaded Cooling coil inches 1/2" Heating coil inches 1/2" DIMENSIONS Rect-rect L x W x H mm 698 x 1200 x 250 Circ-Circ L x W x H mm 1014 x 1200 x 250 WEIGHT Rect-rect Unit weight kg 42 Circ-circ Unit weight kg 48 1) Air: 27 C DB/19 C WB, Water in: 7 C/12 C, 50 Pa external static pressure. (2) Air: 20 C, Water in: 50 C, same water flow as in cooling, 50 Pa external static pressure. (3) Air: 20 C, Water in: 70 C/60 C, 50 Pa external static pressure. (4) According Eurovent standard: Return + radiated sound power level given for a unit with 50 Pa external static pressure in medium speed. (5) Sound pressure considering an hypothetical installation and local attenuation of 21 db. Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +60 C 15 bars Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) 5 C/15% RH 32 C/70% RH 44 45

24 Pressure ductable fan coil unit AccessorIes DUCTYS AND VH AccessorIEs PRC KS BCA TRM-VP TRM-FA TAE20 TAE20+SEH Mechanical sensor for automatique change over Suspension Kit Bac Condensats Auxiliaire Remote thermostat with summer/winter manual switch - action on control valve Remote thermostat with summer/winter manual switch - action on control valve and fan Electronic thermostat TAE20 Electronic thermostat TAE20 + change over sensor SEH SChange over sensor for TAE 20 AQS WPT AQS RCL µbms NIU ENIU IR Rec Aquasimp control for ceiling concealed Water sond temperature for Aquasimp RCL remote control (supplied loose) µbms supervisor µbms compatible communication board NIU for Aquanet Modbus communication board eniu for Aquanet Ceiling concealed IR for Aquanet (Aquanet no included) DUCTYS 1500 DUCTYS 2000 DUCTYS 2500 VH07 VH15 VH18 VH21 VH24 VH27 7ACEL1346 Price 338 7ACFH0820 7ACTL0486 Price N/A N/A N/A 7ACTL0096 Price N/A N/A N/A 34 7ACEL1444 Price 72 7ACEL1442 Price 61 7ACEL1451 Price 194 7ACEL1452 Price 234 7ACEL1233 Price 47 7ACEL1546 Price 87 7ACEL1547 Price 17 7ACEL1547 Price 43 7ACEL1450 Price 260 7ACEL1462 Price 27 7ACEL1463 Price 36 7ACEL1364 Price 215 THERMIcs VALVES 230V DT15 DT20 DT25 VH7 VH15 VH18 VH21 VH24 VH27 2V/TOR/2T 2V/TOR/4T 4V/TOR/2T 4V/TOR/4T 2 Pipes - 1 valve for 1 coil 2V/TOR/2T 2 Pipes - 2 valves for 2 coil 2V/TOR/4T 1 Pipe -4 valves for 1 coil 4V/TOR/2T 2 Pipes -4 valves for 2 coil 4V/TOR/4T 7ACFH0816 7ACFH0816 7ACFH0816 7ACFH0621 7ACFH0623 7ACFH0623 7ACFH0624 7ACFH0624 NA Price NA 7ACFH0817 7ACFH0817 7ACFH0817 7ACFH0627 7ACFH0629 7ACFH0629 7ACFH0630 7ACFH0630 NA Price NA 7ACFH0818 7ACFH0818 7ACFH0818 7ACFH0609 7ACFH0611 7ACFH0611 7ACFH0612 7ACFH0612 NA Price NA 7ACFH0819 7ACFH0819 7ACFH0819 7ACFH0615 7ACFH0617 7ACFH0617 7ACFH0618 7ACFH0618 NA Price NA 46 47

25 Commercial Air conditioning VPN FAN COIL UNIT COOLING AND HEATING Cooling Capacity: from 1.8 to 12.6 kw Heating Capacity: from 3.5 to 20.0 kw Sizes: 9 Versions: 2-Pipes 2-Pipes/2-Wires Configurations: Horizontal concealed Product Avantages Ease of installation. 3-speed centifugal fan motor. Airflow rate between 170 and 2380 m³/h. 3-row coil for optimized cooling performances. Coil with hydrophilic fins to improve the condensate flow. Extended drain pan. Operating limit for Standard unit Main Options Electrical heater. Ducted plenum for air intake. Main Accessories Control. Cooling (1) VPN Size CAPACITIES Water flow l/h Total cooling capacity W Water pressure drop kpa Heating (2) Heating capacity W SOUND LEVELS - High Speed Sound pressure level - 12 Pa db(a) Sound pressure level - 30 Pa db(a) Sound pressure level - 50 Pa db(a) FANS (LS/MS/HS) Motor Number Blower Number Airflow m³/h 170/255/ /401/ /525/ /668/ /780/ /1050/ /1395/ /1530/ /1785/2380 ELECTRICAL - High Speed Power supply V/Ph/Hz 230 / 1 / 50 Power consumption - 12 Pa W Power consumption - 30 Pa W Power consumption - 50 Pa W WATER CONNECTIONS Water connection inches G3/4" Drain connection inches G3/4" DIMENSIONS L x W x H mm 665x565x x565x x565x x565x x565x x565x x565x x565x x565x248 WEIGHT Unit weight kg (1) Air: 27 C DB / 19,5 C WB, Water: 7 C/12 C (2) Air: 21 C, Water in: 60 C, same water flow as in cooling. product codes: on request OPTIONS Electrical Heater ACCESSORY CODE TRM-VP Remote thermostat withsummer/winter manual switch - action on control valve Kit code 7ACEL1444 TRM-FA Remote thermostat withsummer/winter manual switch - action on control valve and fan Kit code 7ACEL1441 PCO Mechanical sensor for automatique change over Kit code 7ACEL1473 AQS Aquasimp controller for wall mounting Kit code 7ACEL1546 AQS OB Aquasimp controller for AWC mounting Kit code 7ACEL1532 WPT AQS Water probe for Aquasimp Kit code 7ACEL1547 TAE20 Electronic thermostat TAE20 Kit code 7ACEL1451 TAE20+SEH Electronic thermostat TAE20 + change over sensor Kit code 7ACEL1452 SEH Change over sensor for TAE 20 Kit code 7ACEL1233 AQN FCC controller all configurations supplied loose for Aquafan Kit code 7ACEL1432 AQN ACC Aquanet accessories - 6 plugs + 4 jumpers + RCL connector Kit code 7ACEL1492 NIU µbms compatible communication board NIU for Aquanet Kit code 7ACEL1462 ENIU Modbus communication board eniu for Aquanet Kit code 7ACEL1463 mbms µbms supervisor Kit code 7ACEL1449 RCL RCL remote control (supplied loose) Kit code 7ACEL1446 IR Rec Wall IR receiver for Aquanet (Aquanet not included) Kit code 7ACEL1364 Minimum water temperature Maximum water temperature Maximum operating pressure +5 C +90 C 16 bars Minimum indoor air temperature (room/intake/around unit) Maximum indoor air temperature (room/intake/around unit) 5 C/15% RH 32 C/70% RH 48 49

26 Control system range for fan coil units A full range dedicated to your needs Electro-Mechanical Control Electronic Control CMV TBMV TRM-VP TRM-FA TAE 20 AQUASIMP AQUANET or RCL Wired remote control Advanced Control Performances. Temperature sensor included. display of temperature. Selection of the speed. LED - On/Off & Default. RC7 Infra red remote control Advanced Control Performances. display of temperature. Selection of the speed. LED - On/Off & Default. UMBS System CMV TBMV TRM-VP TRM-FA TAE 20 AQUASiMP AQUANET 2 Pipes Reversible + valves 2 Pipes / 2 Wires + valves 2 Pipes / 2 Wires reversible + valves 4 Pipes + valves Action No valves (Not recommended) Change over Manual Manual Manual Automatic Manual or automatic Manual or automatic Fan speed selection Manual Manual Manual Manual Manual Manual or automatic Fan action Continuous Fan (1) Cycling fan (2) Continuous fan (1) Cycling fan (2) Master/slaves Continuous (1) or cycling fan (2) Continuous (1) or cycling fan (2) Up to 10 slaves with no additional interface Continuous or cycling fan (2) Up to 15 slaves with only one control device. Mounted Wall mounted Factory fitted Factory fitted 7ACEL1444 7ACEL1441 7ACEL1452 on AWC 7ACEL1432 7ACEL1546 on Aquafan range on Aquafan range 7ACEL1532 Price E ((1) Continuous Fan: Fan runs continuously in cooling or heating mode. (2) Cycling Fan: Fan stops and starts with temperature demand. Carte NIU Managing up to 15 different zone, with a maximum of 80 units. Programming and control of the temperature indivdualized by zone. Weekly programmation. 2 daily ranges configurable by area. Carte e-niu - MODBUS This card allow the connection to a Modbus communication protocol. The NIU card gives an individual adress to each fan coil inside the communication bus system. manual programmation with DIP Switch

27 Water Source Heat Pumps 52 53

28 SElection GUIDE FOR WATER HEAT PUMPS 0KW KW EFTYS HOTEL OFFICES EFTYS 2000 EFTYS 2500 EFTYS kw 2,4 kw 3 kw NR 32 at MS NR 34 at MS NR 37 at MS 452-m³/h at HS 503-m³/h at HS 605-m³/h at HS 50Pa EC LxPxW : 900x530x239 LxPxW : 900x530x239 LxPxW : 900x530x239 CWAR ,9 kw NR 37 at MS 400-m³/h at HS LxPxW : 1138x251x821 CWAR HOTEL OFFICES CWAR 2500 CWAR ,1 kw 2,7 kw NR 38 at MS NR 40 at MS 460-m³/h at HS 510-m³/h at HS N/A EC* LxPxW : 1138x251x821 LxPxW : 1138x251x821 0KW KW HRW019 5,3 kw NR 42 at MS 1250 m³/h at HS >50Pa LxPxW : 900x600x439 HRW027 7,4 kw NR 44 at MS 1185 m³/h at HS >50Pa LxPxW : 1050x660x460 HRW030 8,7 kw NR 43 at MS 1490 m³/h at HS >100Pa LxPxW : 1050x660x460 HRW036 10,1 kw NR 44 at MS 1580 m³/h at HS >100Pa LxPxW : 1250x705x513 HRW SHOPPING HRW042 HRW048 11,4 kw 12,9 kw NR 44 at MS NR 47 at MS 2040 m³/h at HS 2750 m³/h at HS >100Pa >100Pa N/A LxPxW : 1250x705x513 LxPxW : 1250x705x513 HRW060 14,3 kw NR 47 at MS 2840 m³/h at HS >100Pa LxPxW : 1250x705x513 HRW072 17,1 kw NR 48 at MS 3570 m³/h at HS >100Pa LxPxW : 1250x705x513 HRW096 21,7 kw NR 56 at MS 4700 m³/h at HS >100Pa LxPxW : 1680x955x770 HRW kw NR 57 at MS 5600 m³/h at HS >200Pa LxPxW : 1680x955x770 *On request Total cooling capacity at HS, Eurovent conditions. ideal Solution FOR refurbishment, AND R22 UNITS replacement, AS WELL AS FOR NEW APPLICATIONS. Advance scroll technology REFRIGERANT OZONE FRIENDLY TECHNOLOGY AND RELIABILITY Santard protective devices: Flow switch/pressostat on hydraulic circuit HP pressure switch LP pressure switch Fuse holder Rotary or scroll hermetic compressor Energy saving EC fan motor 54 55

29 Water Source Heat Pump STORM 2 Electronic control system ADVANCED FUNCTIANILITIES: Modbus communication as a standard 0-10 V output to control EC motor, 100% modulated Fault reports of eight different possible machine faults Infra red remote control RC07 Four different operating modes for water source heat pumps by selecting the following systems : Thermodynamic cooling and heating operation (RC). Thermodynamic cooling and heating operation or heating operation with an additional electric heater (SH). Thermodynamic cooling operation and electrical heating operation (RH). Thermodynamic cooling operation only (ST). Product Avantages Measurement of the room air temperature Anti-short cycle to protect the compressor Variable sequential start-up function avoiding a power surge Emergency shut-down / stand-by / night setback Automatic HP reset pressure and/or lack of water flowrate Automatic BP reset pressure Défaut isotherme moteur ventilateur Anti-freeze safety function Low temperature limit in coolong/heating mode High temperature limit in coolong/heating mode Antifreeze default in cooling mode Managing of motorized water valves Managing of Master/slave Main functions: Advanced Control Performances. Temperature sensor included. display of temperature. Selection of the speed. LED - On/Off & Default. Remote control RCL Main functions: Digital display On/Off. Selection of the working mode. Display of the room temperature. Display of the room temperature. Selection of the speed of the fan. A keypad lock function is also available. Display LED which shows the operating status of the water source heat pump. Master/slaves control up to 10 units with only one remote control Mini central supervisor UMBS Main functions: Managing up to 15 different zone, with a maximum of 80 units. Programming and control of the temperature indivdualized by zone. Weekly programmation. 2 daily ranges configurable by area

30 Water Source Heat Pump EFTYS WATER SOURCE HEAT PUMP Cooling Capacity: from 1,9kW to 3,0kW Heating Capacity: from 2,7kW to 3,6kW Refrigerant : HFC 407C Sizes : 3 models, 1 casings Versions: RC : cooling and heating ST : cooling only SH : cooling and heating or electric heating RH : cooling and electric heating Configurations: Horizontal concealed installation Product Avantages OFFICES HOTEL NEW A coaxial heat exchanger robust in presence of loaded water. An extended working range +9 to +48. High energetical performances, with EC motor and high COP/EER. Coil at the oultet to avoid the installation of a siphon. Stand-alone STORM2 electronic control with ModBus Communication. Easy access to components through wide removable panels. Many aeraulic and hydraulic configuration to easily replace the unit alread on site. Extended working range through coaxial heat exchanger. Acoustical insulation and compressor isolated and mounted on spring to an optimal acoustical comfort. Anti-corrosion treated drain pan. Low height < 240mm. Conçus & fabriqués en Designed & produced in depuis 1947 Main Options G2/ M1 filter Electrical heater Quick connector General alarm dry contact Circuit breaker Front or lateral ducted plenum for air discharge Fresh air intake Individual packaging Main Accessories FRANCE Room sensor Flow switch for low waterflow protection Motorized water valve µbms mini-supervision station RCL remote control D E EFTYS Size CAPACITIES Total cooling capacity (1) W Sensible cooling capacity (1) W Heating capacity (1) W PERFORMANCES COP (1) 4,12 4,17 4,3 FANS WATER CONNECTIONS EER (1) 3,88 4,13 3,85 Nominal Airflow m³/h Air filter Number / Efficiency 1 / G2 1 / G2 1 / G2 Air filter Dimensions / Thickness mm 225 x 365 / x 365 / x 365 / 20 Nominal water flow l/s 0,116 0,127 0,173 Cutoff water flow vs nominal water flow (2) % WPD at nominal water flow kpa WPD at nominal water flow with valve kpa Hydraulic connections inches Male type ISO G 1/2" INT Condensate outlet - external ø mm ELECTRICAL Power supply V / Ph / Hz 230 / 1 / / 1 / / 1 / 50 Power input - cooling mode (3) W Power input - heating mode (3) W Electrical heater (4) W Fan maximum current (ESP=0Pa) A 0,85 0,85 1,4 Compressor nominal current A 2,8 3,0 4,0 Compressor starting current A ,9 SOUND LEVELS Sound power level intake+rad (5) db(a) 55/57/59 56/58/60 56/58/62 Sound power level Discharge (5) db(a) 53/55/56 54/56/58 58/61/65 Sound pressure level (6) db(a) 34/36/38 35/37/39 37/40/44 NR (6) db(a) 30/32/34 31/34/36 34/37/42 DIMENSIONS L x W x H mm 900x530x x530x x530x239 WEIGHT Unit weight kg (1) Performances given at nominal conditions. Cooling mode: Tair=27 C, Twater=30 C & Heating mode: Tair=20 C, Twater=20 C. (2) Protection by flow switch (accessory). - (3) Absorbed power (compressor + fan) at nominal conditions. (4) Electric heating coil is an optional feature available on SH & RH versions. - (5) Sound power level considering 50Pa available static pressure in high speed, in-line unit configuration with filter. - (6) Sound pressure considering an hypothetical installation and local attenuation of 21 db. Coaxial heat exchanger Compressor on springs FB FA SA F Operating limit for Standard unit Water inlet temperature Return Air temperature Maximum operating pressure Cooling Heating Cooling Heating Min 18 C Max 45 C Min 9 C Max 32 C Min 21 C db / 15 C wb Max 32 C db / 23 C wb Min 15 C Max 25 C 31 bars FC1 FC2 SB Flexibilty of configuration SC1 SC2 NEW : ON STOCK! DESCRIPTION PRICE EFTYS OG EFTYS OG EFTYS OG Configuration of the units on stock Brand Wesper Version Reversible Control Storm2 Remote control RCL Air filter G2/M1 Air inlet Front/ Rectangular: FA Air outlet Front 1 x ø 200 mm (E) Packaging Individual 58 59

31 Water Source Heat Pump AccessorIes - Supplied loose EFTYS 2000 EFTYS 2500 EFTYS 3000 Motorized water valve Water flow switch Inlet plenum kit 7ACFH0500 Price 236 7ACFH0821 Price 72 7ACFH0566 Price 236 AccessorIes regulation - Supplied loose EFTYS 2000 EFTYS 2500 EFTYS 3000 RCL remote control Supervisor - µbms 7ACEL1446 Price 43 7ACEL1449 Price

32 Water Source Heat Pump HRW WATER SOURCE HEAT PUMP Cooling Capacity: from 5,3 to 30 kw Heating Capacity: from 5,8 à 38,1 kw Refrigerant : HFC 407C Sizes : 10 models, 4 casings Versions: RC : cooling and heating ST : cooling only SH : cooling and heating or electric heating RH : cooling and electric heating Configurations: Horizontal concealed installation Product Avantages SHOPPING High efficiency horizontal units with high COP. 5 optimized compact casing. Easy access to components through wide removable panels. in-line or perpenducular air blowing. Brazed stainless steelplate heat exchanger for improved efficiency. flow switch for antifreeze protection as standard. Bi-flow thermostatic expansion valve as standard. Anti-corrosion treated drain pan. float-type safety system to protect agains condensate overflow. Stand-alone STORM electronic control with RCL remote control. Conçus & fabriqués en Designed & produced in depuis 1947 Main Options RCW-2 mini-supervision station. ModBus Communication interface board. 3-speed direct drive fan motor (up to 17 kw) or beltdriven fan with variable pitch pulley (above 17kW). G2 filter as standard, G3 in option*. 15 mm thick thermal and acoustical insulation. M1-class fire insulation. Electrical heater. Motorized water valve. General alarm dry contact. disconnect switch*. Front or lateral ducted plenum for air intake*. Fresh air intake. Individual packaging*. * Available on some models. Main Accessories Room sensor. FRANCE HRW Size CapacitIEs Total cooling capacity W Sensible cooling capacity W Heating capacity W FANS Nominal Airflow m³/h Motor power W Fan speeds Nbr Air filter Number/Efficiency 2/G2 2/G2 2/G2 2/G2 2/G2 2/G2 2/G2 2/G2 Air filter Dimensions/Thickness mm 365x300/25 365x300/25 385x350/25 385x350/25 450x440/25 450x440/25 450x440/25 450x440/25 WATER CONNECTIONS Plate heat exchanger Nbr Nominal water flow (1) l/s 0,256 0,428 0,49 0,564 0,72 0,784 0,93 1,09 Cutoff water flow vs nominal water flow % WPD at nominal water flow (1) kpa WPD at nominal water flow with valve (6) kpa Hydraulic connections inches ISO G 3/4" INT Condensate outlet - external ø mm REFRIGERANT CIRCUIT Number of circuit Compressor type Rotatif Scroll Scroll Scroll Scroll Scroll Scroll Scroll ELECTRICAL Power supply V/Ph/Hz 230/1/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 400/3+N/50 Power input - cooling mode (4) W Power input - heating mode (4) W Electrical heater W Fan maximum current (ESP=0Pa) (7) A 1,5 1,5 2,6 2,4 3,55 4,7 4,7 6,9 Compressor nominal current A 6,6 3,7 4,5 5,4 5,7 7 7,5 10,6 Compressor starting current A , ,5 101 SOUND LEVELS Sound power level (8) db(a) 51/54/58 54/56/57 53/54/57 53/56/58 54/56/58 55/59/63 55/59/63 57/60/63 Sound pressure level (9) db(a) 44/47/51 47/49/50 46/47/50 46/49/51 47/49/51 48/52/56 48/52/56 50/53/56 NR (9) db(a) 39/42/46 42/44/45 41/43/45 41/44/46 42/44/46 43/47/49 43/47/49 45/48/51 DIMENSIONS LxWxH mm 900x600x x660x x660x x660x x705x x705x x705x x705x513 WEIGHT Unit weight kg ACCESSORIES HRW 019 HRW 027 HRW 030 HRW 036 HRW 042 HRW 048 HRW 060 HRW 072 7ACEL1446 RCL remote controller** Price 51 µbms 7ACEL1449 Price 260 (1) Nominal cooling capacities based on: Air: 27 C DB/19 C WB, Entering water temperature: 30 C. (2) Nominal heating capacities based on: Air: 20 C DB/15 C WB, Entering water temperature: 20 C. (3) Protection by flow switch on units HRW 007, 009 & 012, and by differential pressure switch on units HRW 019 to 120. (4) Absorbed power (compressor + fan) at nominal conditions. (5) Electric heating coil is an optional feature available on SH & RH versions. (6) Total water pressure drop with optional water valve fitted. (7) fan power supply: 230V/1Ph for HRW 007 to 072, 400V/3Ph for HRW 096 & 120. (8) Sound power level considering 1,5 m return and discharge duct and unit suspended at 1m. (9) Sound pressure considering an hypothetical installation and local attenuation of 7 db. * Only with return air plenum. ** one RCL is delivery with unit as standard with size 19 to 120. Operating limit for Standard unit HRW HRW Water inlet temperature Cooling Min 18 C 20 C Max 44 C 48 C Heating Min 13 C Max 34 C Return Air temperature Cooling Min 21 C BS/15 C BH Max 38 C BS/28 C BH 38 C BS/28 C BH Heating Min 15 C Max 27 C 25 C Maximum operating pressure 31 bars NEW: en stock! Configuration : Reversibel, summer/winter on ligne, Wesper, Filter G2/M3, remote RCL CODES HRW 019 HRW 027 HRW 030 HRW 036 HRW 042 7OG OG OG OG OG Price CODES HRW 48 HRW 60 HRW 72 HRW 96 HRW 120 7OG OG OG OG OG Price

33 Water Source Heat Pump HRW Size CAPACITIES Total cooling capacity W Sensible cooling capacity W Heating capacity W FANS Nominal Airflow m³/h Motor power W Fan speeds Nbr - - Air filter Number/Efficiency 2/G2 2/G2 Air filter Dimensions/Thickness mm 620x650/25 620x650/25 WATER CONNECTIONS Plate heat exchanger Nbr 1 1 Nominal water flow (1) l/s 1,35 1,78 Cutoff water flow vs nominal water flow % WPD at nominal water flow (1) kpa 55 80,5 WPD at nominal water flow with valve (6) kpa Hydraulic connections inches ISO G 1 1/4" Condensate outlet - external ø mm REFRIGERANT CIRCUIT Number of circuit 1 1 Compressor type Scroll Scroll ELECTRICAL Power supply V/Ph/Hz 400/3+N/50 400/3+N/50 Power input - cooling mode (4) W Power input - heating mode (4) W Electrical heater W Fan maximum current (ESP=0Pa) (7) A 2,5 4,1 Compressor nominal current A 11,4 14,8 Compressor starting current A SOUND LEVELS Sound power level (8) db(a) Sound pressure level (9) db(a) NR (9) db(a) DIMENSIONS LxWxH mm 1680x955x x955x770 WEIGHT Unit weight kg ACCESSORIES HRW 96 HRW 120 RCL remote controller** 7ACEL1446 Price 51 µbms 7ACEL1449 Price 260 (1) Nominal cooling capacities based on: Air: 27 C DB/19 C WB, Entering water temperature: 30 C. (2) Nominal heating capacities based on: Air: 20 C DB/15 C WB, Entering water temperature: 20 C. (3) Protection by flow switch on units HRW 007, 009 & 012, and by differential pressure switch on units HRW 019 to 120. (4) Absorbed power (compressor + fan) at nominal conditions. (5) Electric heating coil is an optional feature available on SH & RH versions. (6) Total water pressure drop with optional water valve fitted. (7) fan power supply: 230V/1Ph for HRW 007 to 072, 400V/3Ph for HRW 096 & 120. (8) Sound power level considering 1,5 m return and discharge duct and unit suspended at 1m. (9) Sound pressure considering an hypothetical installation and local attenuation of 7 db

34 Commercial Air conditioning EWH WATER SOURCE HEAT PUMP Cooling Capacity: from 3.9 to 43 kw Heating Capacity: from 4.3 to 58 kw Refrigerant: R410A Size: 11 models, 7 casings Configurations: Horizontal concealed installation R410A EWH Size CAPACITIES Total cooling capacity kw Heating capacity kw VENTILATION Nominal Airflow m³/h External static pressure Pa HYDRAULIC CIRCUIT Water side heat exchanger type Coaxial Nominal water flow (1) m³/h WPD at nominal water flow (1) kpa Hydraulic connections inches Rc 3/4 R 1-1/4 Condensate outlet - external ø inches G3/4 G1 REFRIGERANT CIRCUIT Refrigerant type R410A Compressor type Rotary Scroll ELECTRICAL Power supply V/Ph/Hz 230/1/50 400/3N/50 Power input - cooling mode W Power input - heating mode W SOUND LEVELS Sound pressure level db(a) 39/40/41 41/42/43 42/43/44 43/44/45 45/46/47 46/47/48 47/48/ DIMENSIONS L x W x H mm 830x531x x592x x650x x747x x852x x1100x x1110x737 WEIGHT Unit weight kg Product Avantages High efficiency horizontal units with high COP. Environment-friendly R410A refrigerant. fitted with high and low pressure switches, refrigerant leakage and water temperature protections. Stand-alone, local or centralized control. Easy installation and servicing. Low sound level. Operating limit for Standard unit Main Accessories Wired remote control Wireless remote control Master control Network board 15m communication link 12V power supply RS485/RS422 adaptor board Data zone control PC monitoring tool (1) Nominal cooling capacities based on: Air: 27 C DB/19 C WB. water In/Out: 30/35 C (2) Nominal heating capacities based on: Air: 20 C DB/15 C WB. water In/Out: 20/35 C PRODUCT CODES: on request ACCESSORY CODE Wired Remote controller C C Wireless Remote controller Receiver Assembly C SYSTEM: GROUP CONTROL Network board C Master Controller C Wire communication 15 m C Power supply Box 12V C Wired Remote controller C C Wireless Remote controller Receiver Assembly C SYSTEM: CENTRAL CONTROL WITH PC Network board C Transfer Card adapter RS485/232 C Zone data collect controller C PC Monitor tool C Wired Remote controller C C Wireless Remote controller Receiver Assembly C Water inlet temperature Return Air temperature Maximum operating pressure Cooling Heating Cooling Heating Min 10 C Max 40 C Min 10 C Max 30 C Min 16 C Max 32 C db/23 C wb Min 15 C Max 27 C 35 bars 66 67

35 Water Source Heat Pump CW - AR WATER SOURCE HEAT PUMP COOLING AND HEATING Cooling Capacity: from 1,9 to 2,7 kw Heating Capacity: from 2,4 to 3,2 kw Refrigerant : HFC 407C Sizes : 3 models Versions: CAR: standard with cabinet CARB: low height with cabinet nu: standard without cabinet nub: low height without cabinet Configurations: Vertical console cabinet Vertical concealed without cabinet Product Avantages OFFICES HOTEL High efficiency vertical units with high COP. Harmonuous and aesthetic RAL9010 painted cabinet design. Streamlined design and elaborate finish enabling harmonious integration. Low consumption EC fan motor or 3-speed AC fan motor. Stand-alone STORM electronic control with RCL remote control. Brazed stainless steelplate heat exchanger for improved efficiency. Easy access to components through front panel. Ease of installation through selection of service side. direct access to Schrader valves (HP & BP). flow switch for antifreeze protection as standard. Anti-corrosion treated drain pan. Conçus & fabriqués en Designed & produced in depuis 1947 Main Options FRANCE RCW-2 mini-supervision station. ModBus Communication interface board. L/R Lateral, back or bottom hydrualic connections. L/R lateral electrical connection. G2 filter. 15 mm thick thermal and acoustical insulation. LONWorks control. bottom return air with feet or front air intake. HP & BP pressure switches. General alarm dry contact. Disconnect switch. Thermostat. CW-AR Size Capacities Total cooling capacity W Sensible cooling capacity W Heating capacity W VENTILATION Nominal Airflow m³/h Motor power W Fan speeds Nbr Air filter Number/Efficiency 1/G2 Air filter (Front) Dimensions/Thickness mm 660x205/6 Air filter (Bottom) Dimensions/Thickness mm 595x187/6 WATER CONNECTIONS Plate heat exchanger Nbr 1 Nominal water flow (1) l/s 0,119 0,133 0,171 Cutoff water flow vs nominal water flow % WPD at nominal water flow (1) kpa 5 3,4 12 Hydraulic connections inches ISO G 1/2" INT Condensate outlet - external ø mm 15x20 REFRIGERANT CIRCUIT Number of circuit 1 Compressor type Rotatif ELECTRICAL Power supply V/Ph/Hz 230/1/50 Power input - cooling mode (4) W Power input - heating mode (4) W Fan maximum current A 0,2 0,25 0,3 Compressor nominal current A 2,8 3 4 Compressor starting current A ,9 SOUND LEVELS (LS/MS/HS) Sound power level db(a) 49/50/51 50/51/53 51/53/54 Sound pressure level (5) db(a) 41/42/43 42/43/45 43/45/46 NR (5) db(a) 36/37/38 37/38/40 38/40/41 DIMENSIONS (LxWxH) Console (STD) (6) mm 1138x251x821 Concealed (STD) (6) mm 1086x229x769 WEIGHT Console (STD) kg Concealed (STD) kg (1) Nominal cooling capacities based on: Air: 27 C DB/19 C WB, Entering water temperature: 30 C. (2) Nominal heating capacities based on: Air: 20 C DB/15 C WB, Entering water temperature: 20 C. (3) Protection by flow switch on units HRW 007, 009 & 012, and by differential pressure switch on units HRW 019 to 120. (4) Absorbed power (compressor + fan) at nominal conditions. (5) Sound pressure considering a local of 100 m ³, a reverberation time of 0,5 sec and a distance of 1 m. (6) Feet included. Operating limit for Standard unit Water inlet temperature Return Air temperature Maximum operating pressure Cooling Heating Cooling Heating Min 23 C Max 42 C Min 12 C Max 34 C Min 21 C BS/15 C BH Max 32 C BS/23 C BH Min 15 C Max 27 C 3 bars 68 69

36 Direct Expansion Range POWER & robustness IN ALL conditions XAR + UC R407C Piston Electromecanical direct expansion range AIR COOLED CONDENSING UNIT 10/55 kw 19/83 kw 12/83 kw FACTORY R407C Scroll Regulation CAC FACTORY CDN R407C Scroll Regulation CAC FACTORY DK DN WATER COOLED CONDENSING UNIT R407C Piston Electromecanical 8/96 kw FACTORY XAO CDN REFRIGERANT OZONE FRIENDLY R410A A RANGE SPECIALLY DEVELOPED for ROBUSTNESS: Weather resistant casing made of heavy gauge galvanized steel coated with powder-based epoxy paint RAL Wide operating limits. High and low operating temperature with fan speed controller. Easy access to technical compartment and to main components. Compressor fitted with crankase heater and mounted on rubber pads. And flexibility with several versions to fit any of your requirements such as acoustical with: - Basic Low Noise version - Extra Low Noise version - Special Inverter Fan version Or refrigerant: - BAZ as standard version - BAC: BAZ with suction accumulator - BAL: BAC with liquid receiver Reliability with Proven TechnologY Standard protective devices: Flow switch/pressostat on hydraulic circuit HP pressure switch LP pressure switch Fuse holder Scroll hermetic compressor + crankcase heater Fan speed controller PRODUCTION SITES OPTIMIZED TO SATISFY YOUR NEEDS Lean Manufacturing Kaizen concept Built-to-order Fan with variable pitch pulley Remote controller Electro-mechanical controller 70 71

37 Direct Expansion DK DN AIR-AIR SPLIT SYSTEM COOLING AND HEATING Cooling Capacity: from 12 to 83 kw Heating Capacity: from 12,4 to 83,8 kw Réfrigérant : R407C Sizes : 12 Configurations: Packaged Split system Product Avantages Weather resistant casing with external panels coated with powder-based epoxy paint colour RAL Indoor centrifugal fan units for duct netwrok connection. High static pressure available. Multi-position architecture for horizontal or vertical mounting (acc. to models). Compact, top discharge outdoor fan units. Low noise axial fan. Scroll compressor with crankcase heater. Electrical, refrigeration and thermal protection devices. Phase controller. External HP and LP pressure taps. Frame and air filter supplied. COOLING MODE Minimum indoor air temperature Maximum indoor air temperature Minimum outdoor air temperature/with all-season kit Maximum outdoor air temperature HEATING MODE Minimum outdoor air temperature Maximum outdoor air temperature Température maxi de l air extérieur NEW: Conform with ERP directive FACTORY Operating limit for Standard unit 21 C BS/15 C BH 32 C BS/23 C BH 15 C BS/-10 C 46 C BS 27 C BS -10 C 24 C BS/18 C BH Conçus & fabriqués en Designed & produced in depuis 1947 Main Options Factory-fitted low ambient temperature control to ensure cooling operation down to -10 C outdoor temperature (All-season). Main Accessories FRANCE Electric heater. Programmable controlller RCW2 to control up to 15 units with independent set points and programming. DK-DN Size DK 155 DK-V 155 DK 205 DK 255 INDOOR UNIT Cool only DN 155 DN 155 DN 205 DN 255 Reversible DN 155RC DN 155RC DN 205RC DN 255RC CapacitIes Cooling capacity kw 14,5 14,5 19,1 21,0 Cooling Power input kw 5,8 5,8 7,3 8,6 EER 2,5 2,5 2,6 2,4 Heating capacity kw 15,7 15,7 18,3 21 Heating Power input kw 5,8 5,8 6,7 7 COP 2,7 2,8 3 2,9 INDOOR UNIT Available static pressure Pa Fan Nominal Airflow m³/h Airflow range (min/max) m³/h 2300/ / / /5100 Sound Levels Sound power level db(a) Dimensions LxWxH mm 1350x745x x972x x1060x x1060x400 Mounting H/V H H/V H H Weight Unit weight kg OUTDOOR UNIT Fan Number of fan Nominal Airflow m³/h Sound Levels Sound power level db(a) Dimensions LxWxH mm 900x800x x800x x800x x800x1060 Weight Unit weight kg POWER SUPPLY Power supply 400V/3P/50 Hz Power supply side Outdoor PIPE LINE Suction pipe diameter < 20m inches 7/8" 7/8" 1-1/8" 1-1/8" Suction pipe diameter > 20m inches 3/4" 3/4" 1-1/8" 1-1/8" Liquid pipe diameter < 20m inches 1/2" 1/2" 1/2" 1/2" Liquid pipe diameter > 20m inches 1/2" 1/2" 5/8" 5/8" Max lenght m Max height m PRODUCT CODE DK205 DK 255 Indoor Unit 7SP SP SP SP Small Fan Price High Fan Price AccessorIes Outdoor Unit - Cool only Outdoor Unit - Reversible Standard With all-season control Standard With all-season control Electric heater Remote control RCW2 Air filter 7SP SP SP SP Price SP SP SP SP Price SP SP SP SP Price SP SP SP SP Price kw 6 10, ACEL1096 7ACEL1209 7ACEL1186 7ACEL1189 Price kw 8, ACEL Price ACVF Price

38 Direct Expansion DK-DN Size DK 305 DK 405 M DK 405 INDOOR UNIT Cool only DN 305 DN 405 M DN 405 Reversible DN 305RC DN 405 mrc DN 405RC CapacitIes Cooling capacity kw 28,5 36,0 37,5 Cooling Power input kw 11,5 13,9 14,4 EER 2,5 2,6 2,6 Heating capacity kw 27,3 36,0 36,5 Heating Power input kw 9,3 13,3 11,9 COP 2,7 3 2,9 INDOOR UNIT Available static pressure Pa Fan Nominal Airflow m³/h Airflow range (min/max) m³/h 4600/ / /8200 Sound Levels Sound power level db(a) Dimensions LxWxH mm 1690x1005x x1005x x1078x676 Mounting H/V H H H Weight Unit weight kg OUTDOOR UNIT Fan Number of fan Nominal Airflow m³/h x9000 Sound Levels Sound power level db(a) Dimensions LxWxH mm 1003xx1003x x1004x x1123x972 Weight Unit weight kg POWER SUPPLY Power supply 400V/3P/50 Hz Power supply side Outdoor PIPE LINE Suction pipe diameter < 20m inches 7/8" 1-3/8" 7/8" Suction pipe diameter > 20m inches 1-1/8" 1-3/8" 7/8" Liquid pipe diameter < 20m inches 5/8" 5/8" 1/2" Liquid pipe diameter > 20m inches 5/8" 5/8" 5/8" Max lenght m Max height m PRODUCT CODE DK 305 DK 405M DK 405 Indoor Unit Small Fan 7SP SP SP Price High Fan 7SP SP Price Outdoor Unit - Cool only Outdoor Unit - Reversible AccessorIes Standard With all-season control Standard With all-season control 7SP SP SP Price SP SP Price SP SP SP Price SP Inclus 7SP Price kw Electric heater 7ACEL1176 7ACEL1177 7ACEL1177 Price kw Remote control RCW2 Price Air filter 7ACVF0125 7ACVF0125 7ACVF0125 Price DK-DN Size DK 505 DK 605 DK 755 DK 905 INDOOR UNIT Cool only DN 505 DN 605 DN 755 DN 905 Reversible DN 505RC DN 605RC DN 755RC DN 905RC CapacitIes Cooling capacity kw 44,0 56,0 69,1 83,0 Cooling Power input kw 16,7 22,5 26,9 33,0 EER 2,6 2,5 2,6 2,5 Heating capacity kw 42,0 57,5 71,0 83,8 Heating Power input kw 14,4 22,9 26,4 32,4 COP 2,5 2,7 2,6 2,5 INDOOR UNIT Available static pressure Pa Fan Nominal Airflow m³/h Airflow range (min/max) m³/h 7500/ / / /15730 Sound Levels Sound power level db(a) Dimensions LxWxH mm 2100x1078x x1078x x949x x949x945 Mounting H/V H H H H Weight Unit weight kg OUTDOOR UNIT Fan Number of fan Nominal Airflow m³/h 2x9000 2x9000 2x x16000 Sound Levels Sound power level db(a) Dimensions LxWxH mm 1708x1123x x1123x x1345x x1345x1459 Weight Unit weight kg POWER SUPPLY Power supply 400V/3P/50 Hz Power supply side Outdoor PIPE LINE Suction pipe diameter < 20m inches 7/8" 1-1/8" 1-1/8" 1-3/8" Suction pipe diameter > 20m inches 7/8" 1-1/8" 1-3/8" 1-3/8" Liquid pipe diameter < 20m inches 1/2" 1/2" 5/8" 5/8" Liquid pipe diameter > 20m inches 5/8" 5/8" 5/8" 5/8" Max lenght m Max height m PRODUCT CODE DK 505 DK 605 DK 755 DK 905 Indoor Unit Small Fan 7SP SP SP SP Price High Fan 7SP SP Price Accessories Outdoor Unit - Cool only Outdoor Unit - Reversible Standard With all-season control Standard With all-season control 7SP SP SP SP Price SP SP Inclus Inclus Price SP SP SP SP Price SP SP Inclus Inclus Price kw Electric heate 7ACEL1178 7ACEL1178 7ACEL1340 7ACEL1340 Price kw Remote control RCW2 Price Air filterr 7ACVF0126 7ACVF Price

39 Direct Expansion XAR UC VERTICAL AIR CABINET COOLING ONLY NEW: Conform with ERP directive X AR Indoor Unit X 1100 AR X 1900 AR-V X 2450 AR-V X 3250 AR-V X 4650 AR-V X 6450 AR-V CapacitIEs Cooling capacity kw 9,7 16,2 19,8 29,0 38,9 55,0 Cooling Power input kw 4,6 6,8 8,9 12,6 16,9 24,0 EER 2,13 2,38 2,22 2,3 2,3 2,3 Cooling circuit FANS Available static pressure Pa Nominal Airflow m³/h Airflow range (min/max) m³/h 1500/ / / / / /14500 SOUND LEVELS Sound power level db(a) DIMENSIONS LxWxH mm 890x430x x500x x600x x600x x790x x790x1970 Plenum height mm WEIGHT Unit weight kg Cooling Capacity: from 9,7 to 55 kw Refrigerant : R407C Size : 6 Configurations: Split system Product Avantages Easy installation and maintenance. Split system with outdoor condenser fan unit. Treated air distribution to premise by plenum or duct network. Adjustable available static pressure. Temperature control by thermostat. Electrical, refrigeration and thermal protection devices. Indoor unit Minimum air temperature (room/intake/around unit) Maximum air temperature (room/intake/around unit) Outdoor unit Minimum air temperature/with all-season kit Maximum air temperature FACTORY Operating limit for Standard unit 21 C BS/15 C BH 32 C BS/23 C BH 15 C BS/-10 C 46 C BS Conçus & fabriqués en Designed & produced in depuis 1947 Main Options FRANCE Room thermostat. Electric heater. Hot water heating coil. All season system (Cooling mode operation down to outdoor temperatuire of -10 C). Remote fault reporting. Plenum. Duct flange. Valves. Pipe link. FANS SOUND LEVELs DIMENSIONS WEIGHT POWER SUPPLY PIPE LINE PRODUCT CODE AccessorIes Outdoor Unit UC 33 UC 54 UC 74 UC 104 UC 74 UC104 Condenser unit Nominal Airflow m³/h Sound power level db(a) LxWxH mm 885x825x x825x x885x x885x x885x x885x893 Unit weight kg Power supply Power supply side 400V/3P/50 Hz Intérieur Suction pipe diameter inches 1/2" 1/2" 5/8" 3/4" 5/8" 3/4" Liquid pipe diameter inches 3/8" 3/8" 1/2" 5/8" 1/2" 5/8" Max lenght m Indoor Unit - XAR Outdoor Unit + UC Outdoor Unit + UC TTS System "All seasons" Set of female valves Pipe link Electric heater Hot water coil ON/OFF switch and room thermostat "High Fan" Kit report défauts à distance Air distribution duct frame Total rear air intake duct frame Front air distribution plenum Fresh air intake 7XU XU XU XU XU XU Price UC 33 UC 54 UC 74 UC x UC 74 2 x UC 104 7XU XU XU XU x 7XU x 7XU Price UC 54 TTS UC 74 TTS UC 104 TTS 2 x UC 74 TTS 2 x UC 104 TTS - 7XU XU XU x 7XU x 7XU Price ACFH Price ACFH0054 7ACFH0055 7ACFH0056 7ACFH0061 7ACFH0057 7ACFH0060 Price ACFH0210 7ACFH0211 7ACFH0212 7ACFH0213 7ACFH0214 7ACFH0215 Price kw ,5 37,5 45 7ACEL0042 7ACEL0043 7ACEL0057 7ACEL0058 7ACEL0116 7ACEL0119 Price kw 15,5 29,7 38, ACFH0062 7ACFH0063 7ACFH0064 7ACFH0118 7ACFH0180 7ACFH0170 Price ACEL0041 7ACEL0041 7ACEL0032 7ACEL0032 7ACEL0032 7ACEL0032 Price ACVF0023 7ACVF Price ACEL0072 7ACEL0072 7ACEL0071 7ACEL0071 Price ACVF0101 7ACVF0102 7ACVF0050 7ACVF0051 7ACVF0052 7ACVF0052 Price ACVF0041 7ACVF0104 7ACVF0043 7ACVF0044 7ACVF0045 7ACVF0046 Price ACVF0105 7ACVF0106 7ACVF0108 7ACVF0109 7ACVF0110 7ACVF0111 Price ACVF0047 7ACVF Price

40 Direct Expansion XAO VERTICAL WATER CABINET COOLING ONLY Cooling Capacity: from 8 to 45,7 kw Refrigerant : R407C Size : 6 Configurations: Monobloc system Product Avantages Easy installation and maintenance. monobloc system. Public or recycled water operation. Treated air distribution to premise by plenum or duct network. Adjustable available static pressure. Temperature control by thermostat. Electrical, refrigeration and thermal protection devices. INDOOR UNIT Minimum air temperature Maximum air temperature Minimum water temperature Maximum water temperature FACTORY Operating limit for Standard unit 21 C BS/15 C BH 32 C BS/23 C BH +10 C +30 C Conçus & fabriqués en Designed & produced in depuis 1947 Main Options Room thermostat. Electric heater. Hot water heating coil. Remote fault reporting. Plenum. Duct flange. FRANCE X AO Size CX 25 X 1100 AO X 1900 AO X 2450 AO X 3250 AO X 4650 AO CapacitIEs Cooling capacity kw 8,0 11,7 18,0 23,0 32,4 45,7 Cooling Power input kw 2,6 3,8 5,8 7,1 9,8 13,9 EER 3,14 3,08 3,1 3,24 3,31 3,29 Cooling circuit FANS Available static pressure Pa Nominal Airflow m³/h Airflow range (min/max) m³/h 1160/ / / / / /10800 WATER CONNECTIONS Wasted water Recycled water SOUND LEVELs POWER SUPPLY DIMENSIONS WEIGHT PRODUCT CODEs 230V/1P/50 Hz 400V/3P/50 Hz Water flow m³/h 0,34 0,58 0,92 1,45 2 2,8 Pressure drop kpa Water flow m³/h 1,17 2,1 3,4 4,3 5,8 8,3 Pressure drop kpa Sound power level db(a) Power supply 230/1P/50 Hz 400V/3P/50 Hz 400V/3P/50 Hz LxWxH mm 800x407x x430x x500x x600x x600x x790x1970 Plenum height mm Unit weight kg with valve without valve 7XU Price XU XU XU XU XU XU Price XU XU XU Price AccessorIes kw 5, ,5 37,5 7ACEL Electric 230V/1P/50 hz Price heater 400V/3P/50 Hz 7ACEL0018 7ACEL0042 7ACEL0043 7ACEL0057 7ACEL0058 7ACEL0116 Price kw - 15,5 29,7 38, Hot water coil - 7ACFH0062 7ACFH0063 7ACFH0064 7ACFH0118 7ACFH0180 Price ON/OFF switch and room thermostat 7ACEL0030 7ACEL0041 7ACEL0041 7ACEL0032 7ACEL0032 7ACEL0032 Price "High Fan" 7ACVF0025 7ACVF0023 7ACVF Price Sum heating resistance 7ACVF0027 7ACVF0029 inclus Price Remote fault reporting ACEL0072 7ACEL0072 7ACEL0071 Price Air distribution duct frame - 7ACVF0101 7ACVF0102 7ACVF0050 7ACVF0051 7ACVF0052 Price Total rear air intake duct frame - 7ACVF0041 7ACVF Price Front air distribution plenum 7ACVF0112 7ACVF0105 7ACVF0106 7ACVF0108 7ACVF0109 7ACVF0110 Price Fresh air intake - 7ACVF0047 7ACVF Price

41 Direct Expansion CDN AIR COOLED CONDENSING UNIT COOLING MODE Cooling Capacity: from 19 to 83 kw Refrigerant : R407C Size : 8 Configurations: Monobloc system Product Avantages Weather resistant casing with external panels coated with powder-based epoxy paint colour RAL Compatible with any indoor unit. Easy service acces to main components. Hermetic Scroll compressor with crankcase heater. Low noise fan. Phase controller. External HP and LP pressure taps. Electrical, refrigeration and thermal protection devices. FACTORY Conçus & fabriqués en Designed & produced in depuis 1947 Main Options FRANCE BAZ version: complete with standard component and fan speed controller. BAC version: BAZ version + suction accumulator. BAL version: BAZ version + suction accumulator + liquid receiver. CDN UNIT Size CDN 205 CDN 305 CDN 405 M CDN 405 CDN 505 CDN 605 CDN 755 CDN 905 CapacitIEs Cooling capacity kw 18,6 27,8 36,0 35,1 44,4 55,6 69,1 83,0 Power input kw 6,5 9,5 12,4 13,0 16,1 19,0 22,9 27,5 Number of refrigerant circuits FANS Number of fan Nominal Airflow m³/h x9000 2x9000 2x9000 2x x16000 Sound levels Sound power level db(a) POWER SUPPLY Power supply 400V/3P + N + Earth/50 Hz Max current A 16, Max starting current A REFRIGERANT CONNECTION Suction pipe diameter inches 1-1/8" 1-1/8" 1-3/8" 1-1/8" 1-1/8" 1-1/8" 1-3/8" 1-3/8" Liquid pipe diameter inches 1/2" 1/2" 5/8" 1/2" 1/2" 1/2" 5/8" 5/8" DIMENSIONS (LxWxH) mm 900x800x xx1003x xx1003x x1123x x1123x x1123x x1345x x1345x1454 WEIGHT Unit weight kg PRODUCT CODEs M BAC 7SP SP SP SP SP SP SP SP Price BAL 7SP SP SP SP SP SP SP SP Price BAZ 7SP SP SP112203S 7SP SP112204S 7SP112205S 7SP SP112206S Price Operating limit for Standard unit COOLING MODE Minimum outdoor air temperature (with fan speed controller) -10 C Maximum outdoor air temperature 46 C BS 80 81

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h KOG LN Low Noise Chilled Water Cassettes 09, 12 & 18 1.70 to 6.10kW 1.58 to 5.10kW 330 to 920 m3/h KOG LN 9 / KOG LN 12 / KOG LN 18 Design Features Introduction The new low noise chilled water cassettes

More information

SYSEFTYS - SYSHRW THE. Water Source Heat Pumps Range N E W. Water cooled. Refrigerant R407C. from 2.1 to 30.0 kw. from 2.7 to 38.1 kw. models.

SYSEFTYS - SYSHRW THE. Water Source Heat Pumps Range N E W. Water cooled. Refrigerant R407C. from 2.1 to 30.0 kw. from 2.7 to 38.1 kw. models. Air Conditionné Chillers & Heat Centrales Pumps de Water traitement terminals d air Ventilateurs Rooftops Close Sécurité control incendie Water Grilles source et heat Diffusion pumps Composants Direct

More information

KOG LN. Low Noise Chilled Water Cassettes Models 30 & 45

KOG LN. Low Noise Chilled Water Cassettes Models 30 & 45 KOG LN Low Noise Chilled Water Cassettes Models 30 & 45 Design Features Introduction Chilled Water units of the "Cassette" type offer comfortable air conditioning at a low cost of installation. They fit

More information

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW

Refrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW Refrigerant R407C CW-AR Water Source Heat Pumps - Vertical Mounting Version Models 07 to 12 2.4 to 3.1kW 1.9 to 2.7kW Some advantages... RAL 9010 painted cabinet 3-fan speeds G2 filter is supplied as

More information

System architecture. Air treatment Index

System architecture. Air treatment Index System architecture Air treatment Index 88 Index Chilled-water air treatment units Type Range Cooling capacity, kw Heating capacity, kw Air flow, l/s Chilled-water terminal units Cassette Cabinet Concealed

More information

CATALOG Chillers 2014

CATALOG Chillers 2014 CATALOG Chillers 2014 An InternatIonaL sales network 2 NORD-PAS- DE-CALAIS PICARDIE HAUTE- NORMANDIE BASSE- NORMANDIE Tillières-sur-Avre ILE-DE-FRANCE Guyancourt CHAMPAGNE- ARDENNE LORRAINE BRETAGNE PAYS-DE-

More information

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED Just feel well Renewable Energy MADE IN EUROPE A ++ + PRODUCTS High efficiency: ηs %. High flexibily due to DC Inverter compressor: operation optimised

More information

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT TECHNICAL INSTRUCTIONS CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 6 2 pipes 6.00 kw 7.70 kw CWX 8 2 pipes 8.00 kw 10.50 kw CWX 10 2 pipes 9.92 kw 13.00 kw November 2008 10 12

More information

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT 1. GENERAL INFORMATION 1.1 Applications page 2 1.2 Operation» 2 1.3 Performances» 2 1.4 Product range» 2 1.5 Selection software» 2 2. DIMENSIONS AND WEIGHTS» 3 3. COMPONENTS 3.1 Structure» 4 3.2 Coils»

More information

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT. Made in Italy Air Conditioning Wall-mounted Fan Coil QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction Version

More information

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V. Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture of high quality air conditioning equipment for industrial, commercial and residential use. Daikin Europe

More information

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE

More information

YFCN Fan Coil Unit centrifugal fan

YFCN Fan Coil Unit centrifugal fan YFCN Fan Coil Unit centrifugal fan 2 & 4 pipe system A complete range from 0.7 kw to 7.4 kw Wired controls JWC-3V Remote three speeds controller JWC-T JWC-3V + Electronic thermostat and Summer/Winter switch

More information

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling TECHNICAL INSTRUCTIONS CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT Cooling Heating CWX 3 pipes.60 3.9 pipes + electric heating.08.96 +.5 pipes.08.5 CWX 5 pipes.70 5.70 pipes + electric heating.3 5.3 +.50

More information

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT Made in Italy Air Conditioning High Wall Fan Coil -ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction

More information

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor SkyStar SK Cassette Fan Coil Unit with Asynchronous Motor Innovating and beautiful design, seven different sizes, high control flexibility, easy maintenance: the SkyStar chilled water Cassette is the result

More information

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy

More information

technical data Fan coil unit FWB small duct unit

technical data Fan coil unit FWB small duct unit technical data Fan coil unit FWB small duct unit TABLE OF CONTENTS FWB 1. Nomenclature ---------------------------------------------------------------------- 2 2. Features -----------------------------------------------------------------------------

More information

SIMPLICITY FULL MODULARITY?

SIMPLICITY FULL MODULARITY? D E S I G N I N G I N N O V A T I V E S O L U T I O N S AIR CONDITIONING & HEATING SOLUTIONS OR SIMPLICITY FULL MODULARITY? IDROFAN, BECAUSE YOU SHOULD NOT HAVE TO CHOOSE. Hydronic ducted fan coils Cooling

More information

UCS UCS/M UCS/H UCS900

UCS UCS/M UCS/H UCS900 EN UCS UCS/M UCS/H UCS900 EST EST (Energy Saving Technology) is applied to the EURAPO fan coil units and cassette units. It permits to obtain extremely low electrical absorption and a continuous modulation

More information

Conditioning your ambient, maximising your comfort.

Conditioning your ambient, maximising your comfort. Centrifugal fan coils for surface mounting or recessed installation. Cooling capacities from 0,6 to 7,6 kw and heating capacity from 0,8 to 9 kw. Air flow from 100 to 1500 m 3 /h. Cassette with radial

More information

X X Packaged Air Conditioners - Vertical Units Air Cooled Models (AR) Water Cooled Models (AO) Refrigerant R407C to 18.

X X Packaged Air Conditioners - Vertical Units Air Cooled Models (AR) Water Cooled Models (AO) Refrigerant R407C to 18. Refrigerant R407C X 1200 - X 1900 Packaged Air Conditioners - Vertical Units Air Cooled Models (AR) Water Cooled Models (AO) 12.3 to 18.0kW 1500 to 3800 m 3 /h X 1200 / X 1900 1 Product Codes Models AR

More information

Packaged air conditioners vertical units

Packaged air conditioners vertical units X 4650 - X 6450 Packaged air conditioners vertical units q Air cooled models (AC) q Water cooled models (WC) q Refrigerant R407C q Capacities from 38.9 to 55.0 kw X 4650 - X 6450 CONA 74 Version: July,

More information

Just feel well. 2017/2018 Air conditioning

Just feel well. 2017/2018 Air conditioning 1947-20 17 2017/2018 Air conditioning Unique solutions 40 Unique and advanced design for vertical or horizontal installation VERTICAL INSTALLATION q Vertical installation with compact dimensions, only

More information

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units AIR CONDITIONING An air conditioned environment is increasingly expected in retail, commercial and industrial premises. Whilst there will always be a demand for custom built air conditioning the standard

More information

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board SkyStar SK-ECM Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board The SkyStar SK-ECM series, available in 5 models, uses an innovative brushless synchronous permanent magnet electronic

More information

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems Technical Bulletin BT13F002GB-04 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR

More information

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM Air Conditioning Fan Coil Units ICIM ISO 900 - Cert. n 0545/2 Unit heaters Radiant panels Fan coils Air handling units Flues SABIANA ENVIRONMENTAL COMFORT Sabiana is the fan coil that continues the Sabiana

More information

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL Wall mounted fan coil units SYSWALL Wall mounted fan coil units With a tangential

More information

CATALOGUE EUROPE 2007

CATALOGUE EUROPE 2007 airwell.com RESIDENTIAL / TERTIARY / INDUSTRIAL CATALOGUE EUROPE 2007 AIR CONDITIONING & HEATING THE POWER OF A GROUP, THE STRENGTH OF A NETWORK Founded in 1947, Airwell is becoming a leader in air conditioning

More information

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK NEW energy consumption ECM motors ECM Cassette Fan Coil Units www.eurovent-certification.com www.certiflash.com CONTENTS Introduction Page 3 Main components Page 4 EUROVENT Certifications Page 5 Emissions

More information

QTS SELECTION TECHNICAL BOOKLET

QTS SELECTION TECHNICAL BOOKLET EN QTS SELECTION TECHNICAL BOOKLET Bi2 FAN RADIATORS AND FAN COILS Italian company established in 1956 2 Bi2 Bi2 TABLE OF CONTENTS 1 Range of system terminals... 6 1.1 Cabinet system terminals... 6 1.2

More information

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT 90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company

More information

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM 0,7 kw 5,2 kw 1,6 kw 10,2 kw 130 m 3 /h 830 m 3 /h SLIM SLIMxx0 vertical with cabinet bottom vertical Available also with feet SLIMxx8 SLIMxx5 SLIMxx4 SLIMxx9

More information

PRODUCTS GUIDE INTEGRATED COMFORT SYSTEMS

PRODUCTS GUIDE INTEGRATED COMFORT SYSTEMS PRODUCTS GUIDE INTEGRATED COMFORT SYSTEMS Founded in Pordenone in 1979, EURAPO has grown and developed as part of the state-of-the-art industrial scenario of North-East Italy. EURAPO is specialized in

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

SIMPLICITY OR FULL MODULARITY?

SIMPLICITY OR FULL MODULARITY? D E S I G N I N G I N N O V A T I V E S O L U T I O N S AIR CONDITIONING & HEATING SOLUTIONS SIMPLICITY OR FULL MODULARITY? IDROFAN, BECAUSE YOU SHOULD NOT HAVE TO CHOOSE. Hydronic ducted fan coils Cooling

More information

Air Conditioning. Air conditioning. Overview

Air Conditioning. Air conditioning. Overview Air Conditioning Air conditioning Overview Manufacturing around the world Skinnskatteberg, Sweden The Group headquarters, distribution center and largest production site. Production of compact air handling

More information

FAN COIL UNITS. The optimal solution for limited space

FAN COIL UNITS. The optimal solution for limited space FAN COIL UNITS The optimal solution for limited space CLEAN AIR SINCE 1963 Euroclima is a company with extensive international operations with four manufacturing facilities in Italy, Austria and India

More information

QZB "Standard" comfort fan coil

QZB Standard comfort fan coil Key features Vertical or horizontal installation Concealed installation or with decorative cabinet Cooling ( pipes) and heating ( pipes or electrical heating) ECM version for low energy consumption The

More information

AQUAHEAT ADVANCE SPLIT

AQUAHEAT ADVANCE SPLIT AQUAHEAT ADVANCE SPLIT HEAT PUMP INVERTER SPLIT SYSTEM AN AIRWELL GROUP COMPANY Indoor unit Outdoor unit 005 PRODUCT ADVANTAGES INVERTER technology R4A refrigerant 2 versions available: heating only /

More information

Blower-YEFB-020-3R-1maxVel

Blower-YEFB-020-3R-1maxVel YEFB DUCTED UNIT GENERAL FEATURES Structure It is made of 1,0 mm thick galvanised steel. Despite this thickness, a special tool for production allowed to keep a good stiffness, in order to reduce the risk

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

QZHW Fan Coil Unit. Key features. Specifications

QZHW Fan Coil Unit. Key features. Specifications Key features High wall installation Cooling ( pipes) Low noise level Electrical heating coil ECM version for low energy consumption QZHW is a high wall fan coil unit available in sizes and many different

More information

FAN COIL UNITS LASER / LOW BODY / CONCEALED

FAN COIL UNITS LASER / LOW BODY / CONCEALED SAPHIR TECHNICAL LITERATURE FAN COIL UNITS LASER / LOW BODY / CONCEALED Energy Saving Technology EST (Energy Saving Technology) is applied to the Johnson Controls fan coil units and cassette units. It

More information

KPSW CONSOLE TERMINAL UNIT

KPSW CONSOLE TERMINAL UNIT TECHNICAL INSTRUCTIONS KPSW CONSOLE TERMINAL UNIT Cooling Heating KPSW.40 kw.75 kw KPSW.9 kw 4.07 kw KPSW 4.60 kw 5.0 kw November 008 0 7 - GB - 0 MARKING This product marked conforms to the essential

More information

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT EEDEN08-424 technical data Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT EEDEN08-424 technical data Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT Fan coil units 1 Hydronic Systems Fan coil units 1 F

More information

LOW STATIC HYDRONIC DUCTED UNIT

LOW STATIC HYDRONIC DUCTED UNIT LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity

More information

Conditioning your ambient, maximising your comfort.

Conditioning your ambient, maximising your comfort. Centrifugal fancoils for surface mounting or recessed installation. Cooling capacity from 0,6 to 7,6 kw and heating capacity from 0,8 to 9 kw. Air flow from 100 to 1500 m3/h. Cassette with radial fan.

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

E U R O V E N T CERTIFIED PERFORMANCE

E U R O V E N T CERTIFIED PERFORMANCE Compact Horizontal Air-Air Heat Pump Model RTH-7K to 3K Ref.: Y-R719 7 Technical information E U R O V E N T CERTIFIED PERFORMANCE I S O 9 1 ER-8/1991 Clima Roca York S.L. is participating in the EUROVENT

More information

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units Premium Efficiency Heat Recovery Unit D-AHU Modular L Air Handling Units About Daikin Our promise is to ensure that customers can depend on Daikin for the ultimate in comfort, so that they are free to

More information

SysAer. An efficient rooftop unit. Chillers & Heat Pumps Water terminals Rooftops Close control Water source heat pumps Direct expansion.

SysAer. An efficient rooftop unit. Chillers & Heat Pumps Water terminals Rooftops Close control Water source heat pumps Direct expansion. Air Conditionné Centrales de traitement d air Ventilateurs Sécurité incendie Grilles et Diffusion Composants de réseaux Chillers & Heat Pumps Water terminals Rooftops Close control Water source heat pumps

More information

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016 UniTrane Terminals High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line Product Presentation September 2016 Agenda Product overview Key features Product range Controls Emissions Accessories

More information

SIGMA PRISMA LOW BODY CONCEALED

SIGMA PRISMA LOW BODY CONCEALED EN SIGMA PRISMA LOW BODY CONCEALED EST EST (Energy Saving Technology) is applied to the EURAPO fan coil units and cassette units. It permits to obtain extremely low electrical absorption and a continuous

More information

PAC BT LOW TEMPERATURE HEAT PUMP

PAC BT LOW TEMPERATURE HEAT PUMP PAC BT LOW TEMPERATURE HEAT PUMP Just feel well COP up to. EER up to. PAC BT -7 kw A ++ + PRODUCTS Cooling and heating mode. Monobloc system. Available in 3PH (sizes 1 to 1). High flexibily due to DC Inverter

More information

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers : SINGLEPACKAGE CONSOLE UNITS, MONOSPLIT, AIR CONDENSING UNITS APPLICATIONS COMMERCIAL SECTOR CONSOLE UNITS AIR CONDENSING UNITS Always very much appreciated for special installations these units shown their

More information

SPECIFICATIONS CWC - 2P / 4P CWC 020 CWC 030 CWC 040 CWC 050 CWC 070 CWC

SPECIFICATIONS CWC - 2P / 4P CWC 020 CWC 030 CWC 040 CWC 050 CWC 070 CWC APPLICATION GUIDE CHILLED WATER CASSETTE CWC - P/4P English/03-005 INDEX Index AGU CWC-P/4P General Description Specifications Performances tables Sound levels Options Dimensions Unit installation Electrical

More information

NEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545

NEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545 NEW Wall Controls Cert. n 0545 Air Conditioning Ceiling Air Conditioning Elegant CONTENTS Page Introduction 3 Main components 4 Dimension, Weight, Water content 5 Main technical figures 6 Working conditions

More information

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center Uniflair LE TDER-TUER Energy-saving units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDER) > Upflow (TUER)

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

KLIMA Active Chilled Beams

KLIMA Active Chilled Beams KLIMA 2 600 Active Chilled Beams Index Subject Page Index 1 Introduction 2 General description 3-4 Product features 5-6 Dimensions 7 Performance data 8-11 Section example Guide specifications 13 1 Introduction

More information

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding

More information

PHOENIX PNX DCI WALL MOUNTED RANGE AN AIRWELL GROUP COMPANY

PHOENIX PNX DCI WALL MOUNTED RANGE AN AIRWELL GROUP COMPANY PHOENIX PNX DCI AN AIRWELL GROUP COMPANY OUTDOOR UNIT GC 9-12-18 DCI OUTDOOR UNIT GC 21 DCI OUTDOOR UNIT GC 24 DCI RC4 (Actual consumption will depend on how the appliance is used and climate) Ful load

More information

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings. F series close control conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings. 38 The F series units are the ideal solution to cool in systems

More information

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

CFI VERTICAL WATER RECESSED DUCTABLE TERMINAL UNIT

CFI VERTICAL WATER RECESSED DUCTABLE TERMINAL UNIT - 71 CFI -71 VERTICAL WATER RECESSED DUCTABLE TERMINAL UNIT CFI - 71 (---) Size Cooling Heating [kw] [kw] 8,7,2 31 12,7 29,3 41,2 33,4 51,7 43,1 71 21,6 5, REPLACE: B27AC-5-95 G4 The CFI series fan-coils

More information

UniTrane Ductable Units D-line and B-Line

UniTrane Ductable Units D-line and B-Line UniTrane Ductable Units D-line and B-Line Discover the new UniTrane Ductable Units The ideal air-conditioning solutions for your building Air-conditioning plays an important role in the comfort level in

More information

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction Reducted footprint Dual-wall construction Built-in variable frequency drive PLC control Variable speed condenser fan Cooling capacity: 5 to 50 kw Air flow: 1 000 to 12 000 m 3 /h ErP READY Use Precision

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems Technical Bulletin BT13F002GB-00 ELFODuct MP New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems ELFODUCT MP 15-71 SERIES SERIES RECOMMENDED FOR

More information

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5

More information

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit Fan Coil Unit 1 BOSCH Climate 000 Fan Coil Unit 2 Fan Coil Unit Introduction to Bosch Thermotechnology Bosch Thermotechnik GmbH is a leading supplier of resourceefficient heating products and hot water

More information

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning : Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision

More information

SMC DUCTED. High Performance AIR CONDITIONING SYSTEMS

SMC DUCTED. High Performance AIR CONDITIONING SYSTEMS SMC DUCTED High Performance AIR CONDITIONING SYSTEMS NEW SLIM DUCTED SYSTEM h 220 mm 1 Slim and compact The new SMC Ducted system is just 220mm in height for sizes up to 5.94 kw and 310mm for larger systems,

More information

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160) Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160) About Climate Wizard Climate Wizard s unique indirect evaporative heat exchange core provides hyper-efficient cooling of outside air.

More information

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY Easy and fast installation Hydronic module available Compact, reliable and efficient Nominal cooling capacity : 8-40 kw Nominal heating capacity : 17-40 kw 50 410A Cooling or heating USE The air-to-water

More information

Technical documentation Fan coil unit

Technical documentation Fan coil unit Technical documentation Fan coil unit KL wall and ceiling unit Description Wall unit with casing, top discharge 8 unit sizes at an air volume of 150-1077 m³/h, heating outputs up to 13,4 kw, cooling outputs

More information

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

PHOENIX PNX0 DCI. New WALL MOUNTED RANGE. High Glossy Finish AN AIRWELL GROUP COMPANY

PHOENIX PNX0 DCI. New WALL MOUNTED RANGE. High Glossy Finish AN AIRWELL GROUP COMPANY PHOENIX PNX0 DCI New High Glossy Finish AN AIRWELL GROUP COMPANY New High Glossy Finish INDOOR UNIT PNX0 09-12 DCI INDOOR UNIT PNX0 18-21-24 DCI GC 9-12-18 DCI GC 21 DCI GC 24 DCI RC4 and RCW2 CLEAN AIR

More information

HOTEL CHILLED BEAM IQ STAR SILENCIA

HOTEL CHILLED BEAM IQ STAR SILENCIA HOTEL CHILLED BEAM IQ STAR SILENCIA TECHNICAL CATALOGUE 2 IQ Star Silencia Hotel Chilled beam - Technical catalogue IQ STAR SILENCIA HOTEL CHILLED BEAM Silencia unit is designed for use in hotel bedrooms,

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

CASSETTE UNIT. Comfort Circle

CASSETTE UNIT. Comfort Circle CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L Ref.: N-27661 0608 Technical information Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification Program. Products

More information

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R Packaged air conditioning unit condensed by air model RTC 07L to 30L Ref.: Y-R70167 0707 Technical information I S O 9 0 0 1 ER-0028/1991 Johnson Controls Manufacturing España, S.L. is participating in

More information

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-019 TABLE OF CONTENTS DESIGN & SPECIFICATIONS...3 APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL DATA... 5 SPECIFICATIONS...

More information

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS

More information

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2 AIR HANDLING UNITS DESIGN System INFORMATION No off Access Handing Viewed in direction of supply air Finish / Colour Duct Connections Height: Width Velocity: Design Airflow (m3/s) Supply Fan Ability Supply

More information

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA ARGO 245C / 3SC Cooling only model ARGO 235H / 3HP Heat pump model 0.8180.405.2 09/2006 Table of contents Page A SPECIFICATIONS 1) Unit specifications 3

More information

ECM Technology. Technology. Features. Advantages (compared to traditional brushed motors) Power consumption: YFCN versus YFCN-ECM (W/kW)

ECM Technology. Technology. Features. Advantages (compared to traditional brushed motors) Power consumption: YFCN versus YFCN-ECM (W/kW) york air-conditioning products ECM Technology Running costs. Energy consumption. Life cycle. These are 3 issues that are becoming more and more important in the choice of Fan Coil Units. With these criteria

More information

b!klimax radiant wall/ceiling system

b!klimax radiant wall/ceiling system b!klimax radiant wall/ceiling system by We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

FCX FAN COIL SILENT & EFFICIENT. Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option

FCX FAN COIL SILENT & EFFICIENT. Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option FCX FAN COIL SILENT & EFFICIENT Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option THE AERMEC FAN COILS Fan coils and Aermec: a combination where the

More information

CHILLED BEAM CASSETTE IQ STAR LYRA

CHILLED BEAM CASSETTE IQ STAR LYRA CHILLED BEAM CASSETTE IQ STAR LYRA TECHNICAL CATALOGUE 2 IQ Star LYRA Chilled beam cassette - Technical catalogue IQ STAR LYRA CHILLED BEAM CASSETTE The LYRA chilled beam cassette is a compact chilled

More information

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL COOLING CAPACITY FROM 20,8 TO 93,3 kw ED.X 1462 F U Kc 72 FC The range of direct expansion close

More information

APPLICATION GUIDE DUCTABLE FANCOIL ARIA 2. 1,3-6,6 kw ARIA2-AGU-1610-E.

APPLICATION GUIDE DUCTABLE FANCOIL ARIA 2. 1,3-6,6 kw ARIA2-AGU-1610-E. APPLICATION GUIDE DUCTABLE FANCOIL ARIA 2 1,3-6,6 kw ARIA2-AGU-1610-E www.lennoxemea.com INDEX ARIA 2 APPLICATION GUIDE Ref : ARIA2-AGU-1610-E General rules for installation Performance Guidelines Confi

More information