Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted

Size: px
Start display at page:

Download "Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted"

Transcription

1 PCXF14 Chilled ater PRODUCT SYSTEM all Mounted Ceiling Cassette Ceiling Convertible Fan Coil Unit Ducted Product Catalogue Products manufactured in an ISO certified facility. This document contains the most current product information as of this

2 Contents Products Overview Cooling Capacity k all Mounted Type F-L 2 / 3 / 4 / 5 / 6 02 FF-C 2 / 4 / 5 Ceiling Cassette Type * ith Brushless DC Motor FK-E/ FKE-E/ FKE-EH 5 / 6 / 8 / 9 / 11 / Ceiling Convertible Type FE-E 5 / 6 / 7 / 8 / 10 / FC-C 3 / 4 / 6 / 7 / 9 / 11 / 12 / 14 / 16 Ceiling Concealed Type FUD-B 20 / 25 / 30 / Ducted Blower Type 24 Remark: All unit photos in this catalog are solely for illustration purpose, actual outlook may differ slightly. All specifications are subjected to change by the manufacturer without prior notice.

3 all Mounted Type Comfortble Air Flow & Lower Sound Level User given more choice on preferable fan speed, quiet mode or automatic setting. ith the introduction of SCR indoor fan motor, a step-less change of fan speed results in smooth air flow and unnoticeable sound level change during fan speed change. Easy Maintenance Air intake grill is easily detachable to be cleaned with water. Sleep function for Cool and Heat mode Once activated, set temperature will be increased / decreased gradually according to normal sleeping temperature patterns to ensure a comfortable sleeping environment. Sleep Set On 0 1/2 1 2 F-L ireless Remote Controller ired Remote Controller (Option) Temperature Heating -1 C -2 C Hours Cooling -3 C Comfortable Air Flow & Lower Sound Level Stylish Flat-Panel Indoor Quiet Mode Turbo Mode Uniform Air Distribution Easy Maintenance NIM-Able Sleep Function For Cool And Heat Mode Auto Restart ith Last-State-Memory Valve & Valveless Control Options Self Diagnosis Features Compact & Easy To Use ireless Remote Controller Stylish Flat-Panel Ideal blend of style and function. The front panel is designed for contemporary style without compromising on function. Air intake area is designed to ensure smooth air flow profile for better sound quality and optimized volume. Heating mode* Temperature Sleep Set On +0.5 C 0 1/2 1 Cooling mode +0.5 C 2 +1 C Hours Indoor Quiet Mode More quiet room environment. ith up to five selectable fan speeds, users are given more choices. By selecting Quiet mode, the sound pressure level is reduced down to an unobstrusive 24 dba. To quickly cool down the room, Turbo model can be selected for maximum cooling power and highest airflow. 24dBA Is So Quiet You Can Even Hear hispers Auto Restart with Last-State-Memory In case of sudden power failure during operation, unit restarts automatically & unit will operate based on previous setting when power is resumed. Operation Power Failure Stop Power Returns Restart 20 Rustling Of Leaves 24dBA for FM-L 30 Pendulum Of A all Clock 40 Library 50 Normal Office (db) E 2 PROM Setting stored before power failure. SL L M H Turbo Fan Speed Low High Turbo Mode TURBO function is available in COOL and HEAT modes only. Once it is activated, the air-conditioner will run into full power with indoor fan running at MAX speed for 20 minutes. This enables the set temperature to be achieved faster. If TURBO and SLEEP are activated at the same time, the SLEEP mode timer will be reset, it will resume after TURBO function is cleared. Compact & Easy To Use ireless Remote Controller Compact and user friendly wireless remote controller offers: Real Time Clock "Glow in the dark" ON/OFF Button Low, Medium, High fan speed options ON Timer Setting T room T set ireless Remote Controller ired Remote Controller (Option) Start 20min 30min Uniform Air Distribution Automated air swing ensures conditioned air distributed evenly. Self Diagnosis Features This feature helps to detect any faults or malfuctioning in the system and provide user a warning by blinking of the LED lights. 2 3

4 Specification for all Mounted Type ~ 50HZ Ceiling Cassette Compact Type (600x600) F02L F03L F04L F05L F06L (ENTERING ATER TEMP. = 50 C) NOMINAL TOTAL INPUT POER A POER SOURCE V/Ph/Hz REFRIGERANT HIGH AUTOMATIC LOUVER (UP & DON) LCD IRELESS MICRO-COMPUTER REMOTE CFM FF-C ireless Remote Controller ired Remote Controller AIR FLO MEDIUM LO QUIET NOMINAL ATER FLO RATE HEAD LOSS () : 50 C CFM CFM CFM USGPM litres/min Compact Design Fresh Air Intake Stylish & Slim Panel Built In High Head Drain Oump & ater Flow Switch 4 ay Air Discharge & Air Swing Valve Or Valveless Control Options Branch Duct Connection Sleep Function For Cool & Heat Mode Auto Restart ith Last-State-Memory NIM-Able Self Diagnosis Features Choices Of ired Or ithless Remote Controller MAX. ORKING PRESSURE 1608 m/s SOUND PRESSURE LEVEL (H/M/L/Q) dba 34 / 29 / 25 / / 30 / 25 / / 39 / 32 / / 38 / 34 / / 42 / 39 / 37 UNIT DIMENSION H X X D 288 X 800 X X 1065 X 224 PACKING DIMENSION H X X D 344 x 874 x X 1136 X 314 UNIT EIGHT kg 9 14 CONDENSATE DRAIN SIZE CROSS FLO DRIVE HIGH RPM SPEED INDEX OF PROTECTION (IP) MEDIUM RPM LO RPM INDUCTION IP44 E MOTOR INPUT POER RUNNING CURRENT HIGH MEDIUM LO HIGH A MEDIUM A LO A A POLES 4 COPPER DIAMETER 7.00 FIN FACE AREA ALUMINIUM m² RO 2 ATER VOLUME litre AIR QUALITY FILTER QUANTITY pc ASHABLE SARANET FILTER 2 HITE ENTERING ATER TEMPERATURE LEAVING ATER TEMPERATURE 2 DB / 19 C B ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 4 5

5 Compact Design Ceiling Cassette C Series body dimension is only 570 x 570 which can easily fits into a 600 ceiling grid Fresh Air Intake Knock out hole is available at the unit. Installation & accessories need to be field supplied & installed. Keep the introduction of fresh air intake within 20% of the total air flow. Also provide a chamber and use a booster fan. Duct flange (ith insulation material) Intake duct (Field supplied and installed) Stylish & Slim Panel The slim panel can be blended easily into decoration and interior design. Built In High Head Drain Pump & ater Flow Switch The unit comes with a 700 built-in high head drain pump. A safety float is incorporated int he drain pump to monitor its water level ay Air Discharge & Air Swing It comes with 4 way air discharge and air swing function to ensure better air distribution and circulation in the room. Branch Duct Connection Improves air flow distribution when there is an obstruction. It allows for air conditioning of two rooms simultaneously. Sleep Function For Cool And Heat Mode Once activated, set temperature will be increased / decreased gradually according to normal sleeping temperature patterns to ensure a comfortable sleeping environment. Temperature Heating Sleep Set On 0 1/ C -2 C Heating mode* -3 C Hours Cooling Self Diagnosis Features This feature helps to detect any faults or malfuctioning in the system and provide user a warning by blinking of the LED lights. Operation Power Failure Branch duct chamber Discharge duct Room 1 Room 2 E 2 PROM Choices Of ired Or ireless Remote Controller Compact and user friendly wireless and wired remote controller offer : Real Time Clock "Glow in the dark" ON/OFF Button Low, Medium, High fan speed options ON Timer Setting Temperature Stop Sleep Set On +0.5 C 0 1/2 1 Cooling mode Auto Restart ith Last-State-Memory In case of sudden power failure during operation, unit restarts automatically & unit will operate based on previous setting when power is resumed. Power Returns Setting stored before power failure C 2 Restart all +1 C Hours Specification for Ceiling Cassette Compact Type ~ 50Hz FF02C FF04C FF05C (ENTERING ATER TEMP. = 50 C) NOMINAL TOTAL INPUT POER A POER SOURCE V/Ph/Hz REFRIGERANT 4 AY AUTOMATIC LOUVER (UP & DON) LCD IRELESS MICRO-COMPUTER REMOTE HIGH CFM AIR FLO MEDIUM CFM LO CFM NOMINAL ATER FLO RATE USGPM litres/min HEAD LOSS () : 50 C MAX. ORKING PRESSURE m/s SOUND PRESSURE LEVEL (H/M/L) dba 42 / 35 / / 38 / / 40 / 36 UNIT DIMENSION - ( ) ITH PANEL H X X D 250 X 570 X 570 (295 X 640 X 640) PACKING DIMENSION - ( ) PANEL H X X D 316 X 630 X 630 (126 X 700 X 726) UNIT EIGHT (UNIT + PANEL) kg CONDENSATE DRAIN SIZE TURBO DRIVE HIGH RPM SPEED MEDIUM RPM LO RPM INDUCTION INDEX OF PROTECTION (IP) B HIGH INPUT POER MEDIUM MOTOR LO HIGH A RUNNING MEDIUM A CURRENT LO A A POLES 6 COPPER DIAMETER 7.00 ALUMINIUM FIN FACE AREA m² RO ATER VOLUME litre AIR QUALITY FILTER QUANTITY pc ASHABLE SARANET FILTER 1 LIGHT GREY Valve Or Valveless Control Options The design is flexible enough to allow for either valve or valveless control installation. ireless Remote Controller ired Remote Controller ENTERING ATER TEMPERATURE LEAVING ATER TEMPERATURE 2 DB / 19 C B ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 6 7

6 Ceiling Cassette Type (900x900) Multi Comfort - 3 Air Swing Pattern Control To increase the comfort level of the air conditioned area of FK-E series, the system had been built in with three different type of air flow pattern to suit different requirement. * The default setting is pattern 1. The air swing pattern can be selected via wireless remonote control. Optimum Air Discharge Combining 4 ways air discharge and large discharge area on each side, Ceiling Cassette promote even air distribution. The additional feature of automatic air swing helps to distribute the conditioned air more evenly to every corner of the room. Standard Setting Louver is set to swing at the maximum angle for gentle drafts. ireless Remote Controller ired Remote Controller FK-E 65 Pattern 1 65 Multi Comfort - 3 Air Swing Pattern Control Fresh Air Intake Optimum Air Discharge Superior Sound Level Branch Duct Connection Low Height Design Built In High Head Drain Pump & ater Flow Switch Modern & Elegant Panel Low water Pressure Drop Self Diagnosis Features NIM-Able Valve Or Valveless Control Options Sleep Function For Cool & Heat Mode Auto Restart ith Last-State-Memory Choices Of ired Or ireless Remote Controller Draft Prevention Setting ith the aid of Coanda effect, direct draft which may lead to discomfort can be avoided. Superior Sound Level ith the adapted technology from Daikin turbo fan, Ceiling Cassette series is able to achieve exceptional low noise. ith up to 4 selected fan speeds, users are given more choices. By selecting the Quiet mode, the sound pressure level can be as low as 23dBA Pattern Longitudinal vortices generated along serration edges accelerate mixing turbulence which reduces vortex shedding noise. Soil Prevention Setting Even distribution of cooling whilst ensuring ceiling to be kept spotless. Branch Duct Connection Improves air flow distribution when there is an obstruction. It allows for air conditioning of two rooms simultaneously Pattern Branch duct chamber Discharge duct all Fresh Air Intake Knock out hole is available at the unit. Installation & accessories need to be field supplied & installed. Keep the introduction of fresh air intake within 20% of the total air flow. Also provide a chamber and use a booster fan. Room 1 Room 2 Low Height Design Unit height as low as 265 for installation convenience. Duct flange (ith insulation material) Intake duct (Field supplied and installed) 8 9

7 Built In High Head Drain Pump & ater Flow Switch The unit comes with a 700 built-in high head drain pump. A safety float is incorporated int he drain pump to monitor its water level. 700 Modern & Elegant Panel It is designed with unique "round" side contour and new LED light location. The rotateable intake grill promotes uniform installation as well. Low ater Pressure Drop Also coonly known as low head loss actually helps to increase the system efficiency. Self Diagnosis Features This feature helps to detect any faults or malfuctioning in the system and provide user a warning by blinking of the LED lights. Valve Or Valveless Control Options The design is flexible enough to allow for either valve or valveless control installation. Sleep Function For Cool And Heat Mode Once activated, set temperature will be increased / decreased gradually according to normal sleeping temperature patterns to ensure a comfortable sleeping environment. Temperature Temperature Heating Operation Heating mode* Cooling Sleep Set On 0 1/ C Sleep Set On +0.5 C 0 1/2 1-2 C Cooling mode Power Failure +0.5 C Auto Restart ith Last-State-Memory In case of sudden power failure during operation, unit restarts automatically & unit will operate based on previous setting when power is resumed. Stop Choices Of ired Or ireless Remote Controller Compact and user friendly wireless and wired remote controller offer : Real Time Clock "Glow in the dark" ON/OFF Button Low, Medium, High fan speed options ON Timer Setting -3 C 2 E 2 PROM +1 C Power Returns Setting stored before power failure. Hours Hours Restart Specification for Ceiling Cassette Type ~ 50Hz FK06E FK08E FK09E FK11E FK13E (ENTERING ATER TEMP. = 50 C) NOMINAL TOTAL INPUT POER A POER SOURCE V/Ph/Hz REFRIGERANT 4 AY AUTOMATIC LOUVER (UP & DON) LCD IRELESS MICRO-COMPUTER REMOTE HIGH CFM AIR FLO MEDIUM CFM LO CFM QUIET CFM NOMINAL ATER FLO RATE USGPM litres/min HEAD LOSS () : 50 C MAX. ORKING PRESSURE m/s SOUND PRESSURE LEVEL (H/M/L/Q) dba 42/38/32/23 46/42/35/27 48/43/38/30 50/47/43/33 52/49/45/39 UNIT DIMENSION - ( ) ITH PANEL H X X D 265 X 820 X 820 (340 X 990 X 990) 300 X 820 X 820 (375 X 990 X 990) PACKING DIMENSION - ( ) PANEL H X X D 341 X 916 X 916 (125 X 1020 X 1020) 376 X 916 X 916 (125 X 1020 X 1020) UNIT EIGHT (UNIT + PANEL) kg CONDENSATE DRAIN SIZE TURBO DRIVE HIGH RPM SPEED MEDIUM RPM LO RPM INDUCTION INDEX OF PROTECTION (IP) B HIGH INPUT POER MEDIUM MOTOR LO HIGH A RUNNING MEDIUM A CURRENT LO A A POLES 8 COPPER DIAMETER 7.00 ALUMINIUM FIN FACE AREA m² RO ATER VOLUME litre AIR QUALITY FILTER ASHABLE SARANET FILTER QUANTITY pc 1 LIGHT GREY 10 NIM-Able Able to counicate with the versatile NIM networking control module and offers the oppurtunity of one centralized control for a system of multiple indoor units in a building. ireless Remote Controller ired Remote Controller ENTERING ATER TEMPERATURE LEAVING ATER TEMPERATURE 2 DB / 19 C B ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 11

8 Ceiling Cassette Type (900x900) ith Brushless DC Motor FKE-E Comfortable Energy Saving Low Noise Low Maintenance & No Brush Sparking 4 Pipe System Available* Modulating Fan Speed Control Optimum Air Discharge Multi Comfort - 3 Air Swing Pattern Control ireless Remote Controller Branch Duct Connection Low Height Design Built In High Head Drain Pump & ater Flow Switch Superior Sound Level Fresh Air Intake Low ater Pressure Drop Sleep Function For Cool And Heat Mode Choices Of ired Or ithless Remote Controller ired Remote Controller Energy Saving Compared to the traditional AC motor, DC motor offers the advantages of lower power input, higher efficiency and hence more energy saving. Brushless DC motor has less internal resistance and better heat dissipation in the stator coils. As a result, it has higher operating efficiencies since heat can more efficiently dissipate via the stationary motor housing. ith the green building and development being so welcomed now, this Ceiling Casstte type with Brushless DC motor gives you another excellent option to consider. Power Input () Power Consumption Comparison Between AC Motor & DC Motor AC Motor DC Brushless Motor Air Flow (CFM) Energy Saving Maximum 67% Low Noise Due to no brushes or a mechnical coutator, it has less shaft friction or inertia and hence less audible noise as low as 16 dba. Low Maintenance & No Brush Sparking Brushless DC motor does not use carbon brushes or a mechanical coutator, thus, it is low maintenance and non-sparking. 4 Pipe System Available* 4 pipe system allows a distribution system that contains both hot water supply with return lines and a chilled water supply with return lines. * FKE-EH model Modulating Fan Speed Control Fan speed modulates steplessly based on room temperature to reduce the difference between room temperature and set temperature and hence provides maximum comfort and reduces energy consumption. * Available in auto fan mode Room Temperature v.s. CFM Recoended Applications Ceiling Cassette type fan coil with Brushless DC motor provides a green and pleasant environment. Room Temperature CFM Office Home 12 Restaurant 13

9 Specification for Ceiling Cassette Type ~ 50Hz (2 Pipe System) FKE05E FKE08E FKE11E QUIET LO MEDIUM HIGH QUIET LO MEDIUM HIGH QUIET LO MEDIUM HIGH (ENTERING ATER TEMP. = 50 C) INPUT POER A POER SOURCE V/Ph/Hz REFRIGERANT 4 AY AUTOMATIC LOUVER (UP & DON) LCD IRELESS MICRO-COMPUTER REMOTE AIR FLO CFM EXTERNAL STATIC PRESSURE (H/M/L) NOMINAL ATER FLO RATE Pa USGPM Litres/min HEAD LOSS () : 50 C MAX. ORKING PRESSURE 1608 m/s SOUND PRESSURE LEVEL dba UNIT DIMENSION - ( ) ITH PANEL H X X D 265 X 820 X 820 (340 X 990 X 990) 300 X 820 X 820 (375 X 990 X 990) PACKING DIMENSION - ( ) PANEL H X X D 341 X 916 X 916 (125 X 1020 X 1020) 376 X 916 X 916 (125 X 1020 X 1020) UNIT EIGHT CONDENSATE DRAIN SIZE kg TURBO DRIVE SPEED RPM BLDC INDEX OF PROTECTION (IP) E E E MOTOR RUNNING CURRENT A A POLES COPPER DIAMETER 7.00 ALUMINUM FIN FACE AREA m² RO ATER VOLUME Litre AIR QUALITY FILTER QUANTITY pc ASHABLE SARANET FILTER 1 LIGHY GREY Specification for Ceiling Cassette Type ~ 50HZ (4 Pipe System) FKE05EH FKE08EH FKE11EH QUIET LO MEDIUM HIGH QUIET LO MEDIUM HIGH QUIET LO MEDIUM HIGH (ENTERING ATER TEMP. = 50 C) INPUT POER A POER SOURCE REFRIGERANT V/Ph/Hz 4 AY AUTOMATIC LOUVER (UP & DON) LCD IRELESS MICRO-COMPUTER REMOTE AIR FLO CFM EXTERNAL STATIC PRESSURE (H/M/L) Pa NOMINAL ATER FLO RATE () USGPM Litres/min NOMINAL ATER FLO RATE () USGPM Litres/min HEAD LOSS () : 50 C MAX. ORKING PRESSURE 1608 m/s SOUND PRESSURE LEVEL dba UNIT DIMENSION - ( ) ITH PANEL H X X D 265 X 820 X 820 (340 X 990 X 990) 300 X 820 X 820 (375 X 990 X 990) PACKING DIMENSION - ( ) PANEL H X X D 341 X 916 X 916 (125 X 1020 X 1020) 376 X 916 X 916 (125 X 1020 X 1020) UNIT EIGHT CONDENSATE DRAIN SIZE kg TURBO DRIVE SPEED RPM INDEX OF PROTECTION (IP) E BLDC E E MOTOR RUNNING CURRENT A POLES A COPPER DIAMETER 7.00 ALUMINUM FIN FACE AREA m² RO ATER VOLUME Litre AIR ASHABLE SARANET FILTER FILTER QUALITY QUANTITY pc 1 LIGHY GREY NOTE: A) BASED ON EUROVENT CONDITIONS B) ADDITIONAL 10 IS REQUIRED FOR CONDENSATE DRAIN PUMP C) SOUND PRESSURE LEVEL IS TESTED AS PER JIS STANDARD AS BELO: FKE05E - 1.4M BELO THE FACE CENTER OF AIR RETURN OF THE UNIT FKE08/11E - 1.5M BELO THE FACE CENTER OF AIR RETURN OF THE UNIT NOTE: A) BASED ON EUROVENT CONDITIONS B) ADDITIONAL 10 IS REQUIRED FOR CONDENSATE DRAIN PUMP C) SOUND PRESSURE LEVEL IS TESTED AS PER JIS STANDARD AS BELO: FKE05EH - 1.4M BELO THE FACE CENTER OF AIR RETURN OF THE UNIT FKE08/11EH - 1.5M BELO THE FACE CENTER OF AIR RETURN OF THE UNIT ENTERING ATER TEMPERATURE LEAVING ATER TEMPERATURE 2 DB / 19 C B ENTERING ATER TEMPERATURE LEAVING ATER TEMPERATURE 2 DB / 19 C B ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE

10 Ceiling Convertible Type Compact Design Unit height as low as 212 for installation at limited ceiling space. Ceiling and Floor Installating Option The unit is uniquely designed with possiblity to be installed under or sitting on the floor to suit any interior design requirements FE-E ireless Remote Controller ired Remote Controller Far Air Throw Compact Design Far Air Throw Auto Air Swing Service & Maintenance At Ease Ceiling & Floor Installing Option Versatile Installation Room Temperature Sensing Saranet Filter Sleep Function For Cool And Heat Mode Auto Restart ith Last-State-Memory Valve Or Valveless Control Options Self Diagnosis Features NIM-Able Choices Of ired Or ireless Remote Controller Maximum air throw distance up to 16.5m. *all bracket is supplied as optional item. Auto Air Swing The motorized louver enables the air flow to be evenly distributed. Versatile Installation The unit is designed to work with high pressure head drain pump (optional). Thus offering flexibility for installation on condensate drain pipe. The drain pump comes with a high head and is incorporate with the float switch as safery protection. * Drain pump kit supplied as optional item 700 Service & Maintenance at Ease The washable fitler can be easily accessed by just pulling down the intake grill. During servicing or repairing, only the bottom panel needs to be removed in order to access the parts like fan motor, blower, wiring connection, control box, piping connection and so on. Room Temperature Sensing Able to sense the room temperature in order to perform more controls for comfort. Saranet Air Filter The anti fungus air filter removes air-particles from the air

11 Sleep Function For Cool And Heat Mode Once activated, set temperature will be increased / decreased gradually according to normal sleeping temperature patterns to ensure a comfortable sleeping environment. Temperature Temperature Heating Heating mode* Cooling Operation Sleep Set On 0 1/ C Sleep Set On +0.5 C 0 1/2 1-2 C Cooling mode Power Failure +0.5 C Auto Restart with Last-State-Memory In case of sudden power failure during operation, unit restarts automatically & unit will operate based on previous setting when power is resumed. Stop -3 C 2 E 2 PROM +1 C Power Returns Setting stored before power failure. Hours Hours Restart Valve Or Valveless Control Options The design is flexible enough to allow for either valve or valveless control installation. Self Diagnosis Features This feature helps to detect any faults or malfuctioning in the system and provide user a warning by blinking of the LED lights. NIM-Able Able to counicate with the versatile NIM networking control module and offers the oppurtunity of one centralized control for a system of multiple indoor units in a building. Choices Of ired Or ireless Remote Controller Compact and user friendly wireless and wired remote controller offer : Real Time Clock "Glow in the dark" ON/OFF Button Low, Medium, High fan speed options ON Timer Setting ireless Remote Controller ired Remote Controller 62 Specification for Ceiling Convertible Type ~ 50Hz FE05E FE06E FE07E FE08E FE10E FE12E COMING SOON (ENTERING ATER TEMP. = 50 ⁰C) NOMINAL TOTAL INPUT POER A POER SOURCE V/Ph/Hz REFRIGERANT AUTOMATIC LOUVER (UP & DON) LCD IRELESS MICRO-COMPUTER REMOTE HIGH CFM AIR FLO MEDIUM CFM LO CFM NOMINAL ATER FLO RATE USGPM Litres/min HEAD LOSS () : 50 ⁰C MAX. ORKING PRESSURE m/s SOUND PRESSURE LEVEL (H/M/L) dba 50 / 43 / / 51 / / 51 / 44 UNIT DIMENSION H X X D 212 X 1090 X 630 PACKING DIMENSION UNIT EIGHT CONDENSATE DRAIN SIZE H X X D kg 297 X 1197 X BLOER DRIVE HIGH RPM SPEED MEDIUM RPM LO RPM INDUCTION INDEX OF PROTECTION (IP) IP 22 B HIGH INPUT POER MEDIUM MOTOR LO HIGH A RUNNING CURRENT MEDIUM A LO A A POLES 4 COPPER DIAMETER 6.35 ALUMINUM FIN FACE AREA m² 0.27 RO 3 ATER VOLUME Litre 1.11 AIR QUALITY FILTER ASHABLE SARANET FILTER QUANTITY pc 2 HITE NOTE: A) BASED ON EUROVENT CONDITIONS B) ADDITIONAL 10 IS REQUIRED FOR CONDENSATE DRAIN PUMP COMING SOON ENTERING ATER TEMPERATURE LEAVING ATER TEMPERATURE 2 DB / 19 C B ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE

12 Ceiling Concealed Type Excellent Air Distribution The air can be distributed evenly to every corner of the room through ducting. This not only presents a confortable environment, it also enables the installation of multiple area by using only one fan coil unit. Easy To Service Direct access to control box at side panel and filter is accessible from side panel too. Left / Right Piping option For flexible installation and application at site FC-C ired Remote Controller 4 Useable Fan Speed Each speed offers different external static pressure and air flow which enhances flexibility. Valve Or Valveless Control Options The design is flexible enough to allow for either valve or valveless control installation Excellent Air Distribution Compact Design High Capacity Range High External Static Pressure Range Double Protection Drainage East To Service Left/Right Piping Option 4 Useable Fan Speed Valve Or Valveless Control Options Self Diagnosis Features NIM-Able Auto Restart ith Last-State-Memory Choices Of ired Or ithout ired Controller Compact Design Unit height as low as 266 for installation at limited ceiling space. Self Diagnosis Features Ability to detect and diagnose faults and display as error code in the wired controller. NIM-Able Able to counicate with the versatile NIM networking control module and offers the oppurtunity of one centralized control for a system of multiple indoor units in a building Auto Restart ith Last-State-Memory In case of sudden power failure during operation, unit restarts automatically & unit will operate based on previous setting 351 Power Failure Power Returns Operation Stop Restart High Capacity Range From 3k to 16k. High External Static Pressure Range Available up to 167Pa for high static application like the ducting application. Double Protection Drainage System There are primary and secondary drain pan from the standard model, which provide extra protection against condensed or water leaking posibilities. E 2 PROM Setting stored before power failure. Choices Of ith Or ithout ired Remote Controller Compact and user friendly wired remote controller offers: Real Time Clock "Glow in the dark" ON/OFF Button Low, Medium, High fan speed options ON Timer Setting Filter Cover Secondary Drain Pan ith Insulation Primary Drain Pan Polysterene (PS) ith High Impact Polystyrene (HIPS) Cover ired Remote Controller 20 21

13 Specification for Ceiling Concealed Type ~ 50Hz FC03C FC04C FC06C FC07C (ENTERING ATER TEMP. = 50 C) NOMINAL TOTAL INPUT POER A POER SOURCE V/Ph/Hz REFRIGERANT DUCTED IRED MICRO-COMPUTER REMOTE HIGH CFM AIR FLO MEDIUM CFM LO CFM EXTERNAL STATIC PRESSURE Pa 49 / 44 / / 42 / / 45 / / 43 / 30 NOMINAL ATER FLO RATE USGPM litres/min HEAD LOSS () : 50 C MAX. ORKING PRESSURE 1608 m/s SOUND PRESSURE LEVEL (H/M/L) dba 36 / 35 / / 38 / / 41 / / 40 / 36 UNIT DIMENSION H X X D 267 x 702 x x 842 x x 1002 x x 1137 x 351 PACKING DIMENSION H X X D 376 x 951 x x 1091 x x 1251 x x 1386 x 541 UNIT EIGHT kg CONDENSATE DRAIN SIZE BLOER DRIVE HIGH RPM SPEED MEDIUM RPM LO RPM INDUCTION INDEX OF PROTECTION (IP) B HIGH INPUT POER MEDIUM MOTOR LO HIGH A RUNNING MEDIUM A CURRENT LO A A POLES 4 COPPER DIAMETER 9.52 ALUMINIUM FIN FACE AREA m² RO 3 ATER VOLUME litre SARANET AIR QUALITY FILTER QUANTITY pc ENTERING ATER TEMPERATURE LEAVING ATER TEMPERATURE 2 DB / 19 C B ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. NOTE: ALSO AVAILABLE FOR LEFT/RIGHT PIPING AND IRED/IRELESS REMOTE OPTION 22 Specification for Ceiling Concealed Type ~ 50HZ (ENTERING ATER TEMP. = 50 C) NOMINAL TOTAL INPUT POER POER SOURCE ENTERING ATER TEMPERATURE LEAVING ATER TEMPERATURE 2 DB / 19 C B ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. NOTE: ALSO AVAILABLE FOR LEFT/RIGHT PIPING AND IRED/IRELESS REMOTE OPTION FC09C FC11C FC12C FC14C FC16C A V/Ph/Hz REFRIGERANT DUCTED IRED MICRO-COMPUTER REMOTE HIGH CFM AIR FLO MEDIUM CFM LO CFM EXTERNAL STATIC PRESSURE Pa 167 / 128 / / 108 / / 88 / / 137 / / 137 / 98 NOMINAL ATER FLO RATE USGPM litres/min HEAD LOSS () : 50 C MAX. ORKING PRESSURE m/s SOUND PRESSURE LEVEL (H/M/L) dba 46 / 42 / / 48 / / 45 / / 50 / / 50 / 47 UNIT DIMENSION H X X D 384 x 917 x x 1225 x x 1003 x x 1287 x x 1487 x 462 PACKING DIMENSION H X X D 415 x 1126 x x 1461 x x 1245 x x 1497 x x 1701 x 631 UNIT EIGHT kg CONDENSATE DRAIN SIZE BLOER DRIVE HIGH RPM SPEED MEDIUM RPM LO RPM INDUCTION INDEX OF PROTECTION (IP) IP21 IP22 B HIGH INPUT POER MEDIUM MOTOR LO HIGH A RUNNING MEDIUM A CURRENT LO A A POLES 4 COPPER DIAMETER 9.52 ALUMINIUM FIN FACE AREA m² RO ATER VOLUME litre SARANET AIR QUALITY FILTER QUANTITY pc 23

14 Ducted Blower Type Excellent Air Distribution The air can be distributed evenly to every corner of the room through ducting. This not only presents a confortable environment, it also enables the installation of multiple area by using only one fan coil unit. High External Static Pressure Range Available up to 2256Pa for high static application like the ducting application Cabinet Construction It is coated with weatherproofed electro galvanized mild steel casing, with an epoxy is coated with an epoxy polyester powder costing for sever external conditions. Service panel is available at the convenience side as well. FUD20/25B FUD40/50B Left / Right Piping option For flexible installation and application at site. Excellent Air Distribution 4 Useable Fan Speed* Easy To Service Fire-Resistant Polysthylene Insulation Left/Right Piping Option Cabinet Construction High External Static Pressure Range ChangeableDrive Package* Convertible Air Throw Direction* High CFM Range 4 Useable Fan Speed* Each speed offers different external static pressure and air flow which enhances flexibility *Only available for FUD20/25B Fire-Resistant Polyrethylene (PE) insulation is used at every possible condensate panel to prevent all forms of water or moisture penetration. Polyethylene, which is also a type of Closed Cell Foam (CCF) insulation has offered the following advantages: Durable external surface that resists tough dirt and resilient. Higher degree of punsture resistance when compared to fiberglass. Easily cleaned surface (if necessary) to further resist microbial growth. High CFM Range From 20k to 40k and 2500CFM to 4600CFM. Convertible Air Throw Direction* Convertible discharge air direction (vertical or horizontal air throw) provides flexibility in installation at site *Only available for FUD30/40B Changable Drive Package* Changeable belt driven package offers flexibility in customizing project based according to application *Only available for FUD30/40B Duct System Return Air Grille FUD Unit Concrete Plinth Ducted Supply FUD Unit Ducted Return Easy To Service There is a service way allocated at the bottom for servicing available for FUD20/25B Air Discharge Grille Return Air Grille 24 25

15 Specification for Ducted Blower Type ~ 50Hz (ENTERING ATER TEMP. = 50 C) NOMINAL TOTAL INPUT POER POER SOURCE REFRIGERANT HIGH AIR FLO MEDIUM LO EXTERNAL STATIC PRESSURE NOMINAL ATER FLO RATE HEAD LOSS () : 50 C MAX. ORKING PRESSURE SOUND PRESSURE LEVEL UNIT DIMENSION PACKING DIMENSION H X X D H X X D FUD20B FUD25B FUD30B FUD40B A V/Ph/Hz / 3 / 50 DUCTED ITHOUT LER CFM CFM CFM Pa 100 / 72 / / 80 / USGPM litres/min m/s dba 50/46/42 54/52/ x 1402 x x 1540 x x 1605 x x 1787 x 1188 UNIT EIGHT kg CONDENSATE DRAIN SIZE BLOER DRIVE BELT HIGH RPM SPEED MEDIUM RPM LO RPM INDUCTION INDEX OF PROTECTION (IP) IP22 B HIGH INPUT POER MEDIUM MOTOR LO HIGH A RUNNING MEDIUM A CURRENT LO A A POLES COPPER DIAMETER 9.53 ALUMINIUM FIN FACE AREA m² RO ATER VOLUME litre AIR QUALITY FILTER QUANTITY pc IVORY Controller 61 Heatpump with auto mode 62 Cooling only 63 - Heatpump Heatpump with auto mode 62 Cooling only Vertical Automatic Air Swing 2. Selectable Mode: Auto Mode, Cooling, Heating, Dry, Fan 3. Turbo Function 4. Quiet Function 5. ON Timer Setting 6. Real Time Clock 7. Transmission Source 8. Glow in the dark ON/OFF Button 9. Fan Speed Selection: Low, Med, High, Auto 10. Temperature Setting: Up & Down 11. Sleep Mode Function 12. OFF Timer Setting Features: Cool/Heat/Fan/Dry/Auto mode Auto/High/Med/Low fan speed Temperature operate in ºC and ºF Turbo and Quiet Function Sleep function Swing function Real time clock and day display 7-days prograable timer Error indicator Key lock and fan lock features Batteries backup and retain setting during power failure Last state memory (Memory backup setting from main board) Delay Timer (1 or 2 hours) Interaction with ireless Handset (61/62) ENTERING ATER TEMPERATURE LEAVING ATER TEMPERATURE 2 DB / 19 C B ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. NOTE: ALSO AVAILABLE FOR LEFT/RIGHT PIPING

16 Intelligent Control Series Supported Configuration Master Slave Network Interface Module (NIM) is a networking system which enables counication among Daikin air conditioners. ith the Network Interface Module (NIM), all your air conditioning systems can be controlled with just a single controller giving you benefits: Network Control NIM Benefits More convenience. No more individually controlling air conditioning units Quicker and easier zone control from the master control unit Better control of air conditioning systems operating conditions NIM utilizes master-slave type system whereby the master node will issue coands to each of the slave nodes. Every master unit will have a group address so that every slave can only response to their respective master. Each slave unit must have a unique address so that it can be addressed independently of other nodes. The master unit will be operating in conjunction with a control panel. Any settings done via the control panel connected to the master will overwrite the settings of its slave units. Slave unit can be operated with or without control panel. If a slave unit is operating with a control panel, its settings can be changed without following its master. Basic Features DIP switch setting for Group & Unit address. Master or slave system configuration. Automatic detection of control panel existence. Error type and unit ID indication through display control panel. NIM Maximum point to point counication bus up to 1000m. A single master unit can control up to 15 slave units in each group. Each slave unit will sense their individual local temperature. Unit address range from 0 to 15 ( ). The NIM System Consists Of Main Board controller Display control panel NIM controller Counications bus Counication Bus A 2-way twisted pair cable is used as the counication bus. Recoended cable for counication bus is a pair of screened & shielded, twisted single core wire with core diameter of 0.5 to Connection The counication bus must be connected serially to the adjacent NIM. (Daisy chain connection). The same polarity has to be connected between the NIMs (A to A, B to B). G-ay Function Gateway between DX fan coil unit and basic Building Management System (BMS). Note: Remote (On/Off) control of air conditioner via BMS. Unit error indication via BMS and controller. Unit operation status monitoring via BMS. Maximum point to point counication bus between air conditioner and BMS of up to 1000m. DIP switch setting for control or monitoring function. Connection Recoended Maximum Cable Length (m) First NIM to the furthest connected NIM 1000 NIM to Main Board NIM to ired Controller 10 G-ay Connection Types of Operation DS2 Setting Control & Monitor (Ext. Switch Closed = ON A/C) 0000 Control & Monitor (Ext. Switch Open = ON A/C) 0010 (up to total of 16 FCUs) DS2 Setting To ired Control Panel Monitoring only 0001 CN2 Dry Contact Input Dry Contact Switch Master Slave Slave(s) Slave(s) To MainBoard CN1 RELAY 1 NO COM Dry Contact Output 1 Unit On/Off Indicator 28 Main Board Controllers And Display Control Panel NIM must be used in conjunction with: DX fan coil units (except FT(Y)N model. The development is in progress and kindly contact with local distributor for status update.) or RELAY 2 DIP Switch G-ay Controller NO COM Terminal Blocks Dry Contact Output m BMS Unit Error Indicator 29

17 S-NIM For Timer Switchover Control Built on the NIM configuration, S-NIM serves to enhance the abilities and extend the operating lifetime of existing air conditioning units in harsh and demanding environment. S-NIM works in a master & slave system, operating at alternate sequence of preset hours. henever the operating unit is at fault, the standby unit will automatically takes over. S-NIM Features Auto restart feature with last state settings. 2 air conditioning units in a master & slave system, operating at alternate sequence of preset time (3/4/5/7/9/11/12 hours). System controlled by a single controller. hen the operating unit is at fault, the standby unit automatically takes over. Error indication via error code displayed on LCD panel. (only is using Netware 3 control panel) During system OFF mode, running timer will stop. It resumes when changing to ON mode. Preset operation hours can be set via DIP Switch. * The air conditioning unit connected to the wired controller is always the master unit. The S-NIM System Consists Of Main Board controller Counication Bus S-NIM controller Counication Bus A 2-way twisted pair cable is used as the counication bus. Recoended cable for counication bus is a pair of screened & shielded, twisted single core wire with core diameter of 0.5 to 1.0. S-NIM Controller Application Server Room Telecounication Tower Livestock Breeding Farm arehouse Laboratory Railway Switching Center Room with Critical Electronics Equipments Main Board Main Board S-NIM S-NIM Slave Unit Control Panel Master Unit Typical connection structure for S-NIM 30

Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted

Fan Coil Unit. Product Catalogue. Chilled Water PRODUCT SYSTEM PCXF14. Wall Mounted. Ceiling Cassette. Ceiling Convertible. Ducted PCXF14 Chilled ater PRODUCT SYSTEM all Mounted Ceiling Cassette Ceiling Convertible Fan Coil Unit Ducted Product Catalogue Products manufactured in an ISO certified facility. This document contains the

More information

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan.

PCXSPH1732A. Warning. Head office: Umeda Center Bldg., , Nakazaki-Nishi, Kita-ku, Osaka, Japan. Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

Inverter Wall Mounted Series

Inverter Wall Mounted Series PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia

More information

PLXSID1605. Warning HEAD OFFICE :

PLXSID1605. Warning HEAD OFFICE : Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

Ceiling Mounted Cassette Unit

Ceiling Mounted Cassette Unit Brochure AP-MCK-13 Ceiling Mounted Cassette Unit Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date

More information

PCXGA13. Air-Cooled PRODUCT SYSTEM. Residential. Light Commercial. All Product. Commercial / Industrial. Catalogue. For internal reference only R22

PCXGA13. Air-Cooled PRODUCT SYSTEM. Residential. Light Commercial. All Product. Commercial / Industrial. Catalogue. For internal reference only R22 PCXGA13 Air-Cooled PRODUCT SYSTEM Residential Light Commercial All Product Commercial / Industrial Catalogue For internal reference only R22 Since its establishment in 1974, OYL has developed into a large

More information

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V

PLXRMM1606B. Wall Mounted. FTN-A Series. COOLING ONLY [50Hz] V PLXRMM1606B Wall Mounted FTN-A Series COOLING ONLY [50Hz] 220-240V ELEGANT, EFFICIENT 1 Daikin s FTN-A series wall mounted air conditioner that not only saves energy but also ozone friendly. Stylish Flat

More information

Floor Standing. FV Series PLXSPH1502. COOLING ONLY [60Hz]

Floor Standing. FV Series PLXSPH1502. COOLING ONLY [60Hz] PLXSPH1502 Floor Standing FV Series Dealer Lot 60334, Persiaran Bukit Rahman Putra 3, Taman Perindustrian Bukit Rahman Putra, 47000 Sungai Buloh, Selangor Darul Ehsan, Malaysia http://www.daikin.com/global_ac/

More information

Ceiling Mounted Cassette Unit

Ceiling Mounted Cassette Unit CEILING CASSETTE A5CK-E SERIES - R410A COOLING ONLY A5CK20E A5CK25E A5CK28E A5CK40E A5CK40E A5CK40E A5CK40E A5CK50E A5LC20C A5LC25C A5LC28C A5LC35D A5LC35D A5LC40D A5LC40D A5LC50D Btu/hr 18300 22200 27000

More information

RC-0219-A. Single-Split Non Inverter Series

RC-0219-A. Single-Split Non Inverter Series TM RC-0219-A Single-Split Non Inverter Series R32 The Superior Refrigerant This game changing refrigerant strikes the perfect balance between energy efficiency, ease of use and environmental sustainability;

More information

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless

More information

TM: MCCKCM - W B. Fan Coil Units. Models: MWM-FW Series MCM-DW Series MCK-AW/BW Series MCC-CW Series MDB-BW Series

TM: MCCKCM - W B. Fan Coil Units. Models: MWM-FW Series MCM-DW Series MCK-AW/BW Series MCC-CW Series MDB-BW Series TM: MCCKCM - W - 2150B Fan Coil Units Models: MWM-FW Series MCM-DW Series MCK-AW/BW Series MCC-CW Series MDB-BW Series Contents Features... 1 Specifications... 3 Unit Selection Procedure... 11 Cooling

More information

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode. HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy

More information

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make. All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing

More information

Inverter Wall Mounted

Inverter Wall Mounted PLXRHK1603 Inverter Wall Mounted FTKS-A Series COOLING ONLY What is inverter technology? Inverter system ensures faster cooling with signifi cant energy saving. Moreover, it helps to maintain consistent

More information

Hi - Wall Split Systems 12K - 18K - 24K

Hi - Wall Split Systems 12K - 18K - 24K R22 220-240V ~ 50Hz 1Ph Hi - Wall Split Systems 12K - 18K - 24K Technology Tropical Compressor Super Quiet Auto Auto Fan Speed Auto Restart Function Self diagnostic function Active Carbon Electrostatic

More information

AIR CONDITIONER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER

AIR CONDITIONER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER AIR CONDITIONER manufactured with latest inverter Technology 97% of operating power from solar energy very low Power consumption levels Eco-friendly, reduced

More information

Multi Digital Scroll System (R-22 and R-410A)

Multi Digital Scroll System (R-22 and R-410A) Multi Digital Scroll System (R-22 and R-410A) All Product Brochure About Acson International ith products available in more than 55 countries spread across 7 continents around the world, Acson is truly

More information

Inverter Wall Mounted

Inverter Wall Mounted Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing. R407C 220-240V ~, 50Hz Hi - Wall Split Systems Technology Tropical Compressor Super Quiet Auto Mode Auto Restart Easy Flexible Installation IAQ Anti-dust Filters AMS AMS Wireless Control Independent Dehumidification

More information

Wall Mounted Split Systems

Wall Mounted Split Systems MWM - 2005 Wall Mounted Split Systems Models: MWM 007F/FR MWM 010F/FR MWM 015F/FR MWM 020F/FR MWM 025F/FR MWM 030F/FR Contents Features... 1 Nomenclature... 2 Specifications... 3 Performance Table... 11

More information

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems Models: ACC 75D/DR ACC 100D/DR ACC - D2-2007 (Draft) Ceiling Concealed Split Systems CONTENTS 1. NOMENECLATURE... 2 2. FEATURES... 4 3. PRODUCT LINE UP... 5 4. SPECIFICATIONS... 8 5. OPERATING RANGE...

More information

Residential and Light Commercial Ductless Systems Catalog

Residential and Light Commercial Ductless Systems Catalog Residential and Light Commercial Ductless Systems Catalog May 2018 Table of Contents Midea Global 3 Ductless Benefits 5 Single and Multi-Zone Solutions 9 Single Zone Residential 13 Max Series 15 Advantage

More information

Inverter Wall Mounted

Inverter Wall Mounted Warning Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether

More information

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump R 410A Ductless Split System Air Conditioner and Heat Pump Models DLC4(A/H) Outdoor Unit, DLF4(A/H) Indoor Unit Sizes 9K, 12K, 18K, 24K, 30K and 36K Please read the operating instructions and safety precautions

More information

Air conditioners Cooling only

Air conditioners Cooling only Air conditioners Rooftop, an economical solution for medium to large spaces Plug and play for easy installation High efficiency Quick cooling Wide operation range Compact unit www.daikinme.com UAT-CGXY

More information

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1 TVR 5G GUIDE SPECS TVR 5G GUIDE SPECS - JUL.2014 Page 1 Part 1 TRANE VARIABLE REFRIGERANT FLOW SYSTEM 1.1 General PRODUCT Unit shall be air cooled variable refrigerant flow system, module split type multi-system

More information

McQuay HydroflexTM Residential and Light Commercial Chilled Water System

McQuay HydroflexTM Residential and Light Commercial Chilled Water System Advanced, affordable chilled water solutions. McQuay HydroflexTM Residential and Light Commercial Chilled Water System McQuay Hydroflex System Chilled Water Solutions Made Affordable Benefits: Advanced

More information

Inverter Y Series.

Inverter Y Series. Inverter Y Series Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information, please

More information

ECOELEGANT SERIES INSTALLATION OPERATION AND SERVICE MANUAL (AMERICAS VERSION) HW~ECM SERIES

ECOELEGANT SERIES INSTALLATION OPERATION AND SERVICE MANUAL (AMERICAS VERSION) HW~ECM SERIES ECOELEGANT SERIES INSTALLATION OPERATION AND SERVICE MANUAL (AMERICAS VERSION) HW~ECM SERIES Revised: July 11, 2016 Page 1 of 57 INVESTING IN QUALITY, RELIABILITY & PERFORMANCE. ISO 9001 QUALITY World

More information

Wall Mounted Split Systems G-Series AP - MWM - G - 06A

Wall Mounted Split Systems G-Series AP - MWM - G - 06A Wall Mounted Split Systems G-Series AP - MWM - G - 06A Air Purifying System Negative Ion Generator (Standard) The Ion Generator releases negative ion shower to create a refreshing and clean environment

More information

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump 0-40V ~ 0Hz Ph 80-40V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Green Medium Static Pressure Ducted Split System Heat Pump - 8-4 - 0 - - 48-0 DC Inverter Inverter Technology $ Efficient

More information

Amena s Globo series are a group of air conditioning products designed for markets where maximum

Amena s Globo series are a group of air conditioning products designed for markets where maximum mena s Globo series are a group of air conditioning products designed for markets where maximum ambient temperatures are not more than 43 C. These products are available in both cooling only and heatpump

More information

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz] PCRHK1543 Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical

More information

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED Your Climate. We're There. TM: MDB B 2140B Ducted Split Systems Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR REGISTERED Air Conditioning Contents Nomenclature System... 2 Features... 2 General Specifications...3-5

More information

Heat Pump Air Conditioning Systems

Heat Pump Air Conditioning Systems Heat Pump Air Conditioning Systems Create your own Utopia. In a climate as diverse as ours air conditioning your premises can make a huge difference to the comfort of your staff, and your customers too.

More information

R410A Non Inverter High Static Ducted Unit

R410A Non Inverter High Static Ducted Unit FBHVN-1117-D R410 Non Inverter High Static Ducted Unit R410 Indoor Unit (Single Skin Ducted Type) Outdoor Model Product Line Up FBHN80/100HBV1X FBHN125/150HBY1C FBVN200H2BY1C FBVN300/350H3BY1C FBVN400/500H4BY1C

More information

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 TABLE OF CONTENTS PAGE SAFETY PRECAUTIONS... 2 GENERAL... 2 INDOOR UNIT PART NAMES... 3 REMOTE CONTROL PART NAMES...

More information

RG57F3(B)/BGEFU1 Wireless Remote Controller. Service Manual

RG57F3(B)/BGEFU1 Wireless Remote Controller. Service Manual RG57F3(B)/BGEFU1 Wireless Remote Controller Service Manual TABLE OF CONTENTS PAGE INTRODUCTION... 1 HANDLING THE REMOTE CONTROLLER... 2 STANDARD FUNCTION BUTTONS... 3 ACCESSING THE SERVICE FUNCTIONS...

More information

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO. MISR REFRIGERATION & AIR CONDITIONING MFG. CO. COOL EER HEAT COP 0V ~ 50Hz 1Ph Inverter High Wall Split Systems For Energy Saving Heat Pump 1K - 18K - 4K DC Inverter R-410A Inverter Technology R-410A HFC

More information

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA... FIXED FREQUENCY U-MATCH AIR CONDITIONERS TECHNICAL SALES GUIDE Capcity Range: 18000~ 60000 Bth h T3R2250Hz CONTENTS 1. MODELS LIST... 3 2. NOMENCLATURE... 4 3. FEATURES... 5 4. PRODUCT DATA... 9 5. FAN

More information

Ducted inverter reverse cycle air conditioning

Ducted inverter reverse cycle air conditioning Ducted inverter reverse cycle air conditioning What is ducted inverter reverse cycle air conditioning? Ducted inverter reverse cycle air conditioning is an ideal solution for whole-of-home or office cooling

More information

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH MHWW NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Hi-Wall Fan Coil MHWW- 24 - H -1 2-Pipe Heat/Cool Heat/Cool Voltage 1=

More information

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH MHWW NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool Hi-Wall Fan Coil MHWW- 09 - H -1 2-Pipe Heat/Cool Heat/Cool Voltage 1=

More information

Product Section New Product Introduction

Product Section New Product Introduction New Product Product Section New Product Introduction New Product Wall Mounted WM20/25G - WM07/09/10/15G(GR) launched on 2003/2004 - With G11/G12 Handset WM07/09/10/15G Model WM07G(GR) WM09G(GR) WM10G(GR)

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (3278-M) BORA Series WALL MOUNTED SPLIT UNIT NON-INVERTER Series Concealed display Hidden temperature display on a classy

More information

(Non-Inverter & Inverter) R410A

(Non-Inverter & Inverter) R410A LG Commercial Air Conditioner Sinlge Split Type (Non-Inverter & Inverter) R410A Distributed by LG Electronics www.lg.com http://partner.lge.com Copyright 2015 LG Electronics. All rights reserved. Non-Inverter

More information

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M) WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (1132718-M) WALL MOUNTED SPLIT UNIT LOMO N Series WALL MOUNTED SPLIT UNIT R410A Eco-friendly Refrigerant Quiet Fast Cooling

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Wall mounted type DESIGN & TECHNICAL MANUAL INDOOR ASYG07KGTA ASYG09KGTA ASYG12KGTA ASYG14KGTA OUTDOOR AOYG07KGCA AOYG09KGCA AOYG12KGCA AOYG14KGCA DR_AS049EF_02 2017.10.11 Notices: Product

More information

Chilled Water System.

Chilled Water System. Chilled ater System Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information, please

More information

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE

More information

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump 0-0V ~ 0Hz Ph 0-0V ~ 0Hz Ph Slim Line Ceiling Concealed Ducted Split Systems Ducted Split System Heat Pump - - - 0 - - - 0 DC Inverter Inverter Technology $ Operation Hydrophilic Aluminum Fins Independent

More information

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS 40MAQ High Wall Ductless System Sizes 09 to 36 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PART NAMES... 3 FUNCTION BUTTONS... 4 DISPLAY PANELS... 5 REMOTE CONTROL... 6

More information

Wired Controller XK60

Wired Controller XK60 Owner's Manual Commercial Air Conditioners Thank you for choosing Commercial Air Conditioners, please read this owner s manual carefully before operation and retain it for future reference. User Notice

More information

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems Technical Guide Multizone: Multi-Split Type Heat Pump Systems 1 Another Hitachi Day 1 Wall Mounted (RAK) Imagine choosing your perfect day then instantly creating it in the comfort of your own home. With

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 23 8129 VARIABLE REFRIGERANT A. Variable refrigerant volume HVAC system includes: 1. Outdoor/condensing unit(s). 2. Indoor/evaporator units. 3. Branch selector

More information

Air Conditioners Technical Data

Air Conditioners Technical Data Air Conditioners Technical Data W a l l m o u n t e d u n i t E E D E N 2-0 0 4 FTXN-L Indoor Unit Wall mounted unit FTXN-L TABLE OF CONTENTS FTXN-L Features.............................................................

More information

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF 2016 Commercial Air Conditioners VRF 60Hz V4+SV4+RV4+WMini VRF OUTDOOR UNIT LINEUP INDOOR UNIT LINEUP 1.8 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 10.0 11.2 12.5 14.0 16.0 20.0 25.0 28.0 40.0 45.0 OUTDOOR UNIT

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

C&H NORDIC Commercial 4 SERVICE MANUAL

C&H NORDIC Commercial 4 SERVICE MANUAL C&H NORDIC Commercial 4 SERVICE MANUAL CONTENTS PRODUCT...3 1 MODELS LIST... 3 1.1 Outdoor Unit.... 3 1.2 Indoor Unit.... 4 2 PRODUCT DATA.... 5 2.1 Product Data of Indoor Unit... 5 2.2 Operation Range...

More information

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE GREE Multi 21 systems, with inverter technology, are some of today s most advanced ductless split heat pumps. Providing both cooling and heating

More information

Light commercial range. Passion at work

Light commercial range. Passion at work Light commercial range Passion at work 2 Light Commercial Solutions for professionals, from professionals Toshiba-Carrier Super Digital Inverter systems deliver exceptional operating savings in extremely

More information

Non Inverter Wall Mounted Series

Non Inverter Wall Mounted Series FTV-1217-A The Next-Generation Refrigerant Non Inverter Wall Mounted Series TM Since the day we began in Osaka almost a century ago, we have been championing the fight for better air quality indoors. After

More information

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE. WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE. 02 - The Perfect Climate Kaden Wall Mounted Air Conditioners Creating the perfect climate in your home is essential for your family s comfort. Kaden

More information

A single answer for multiple zones.

A single answer for multiple zones. Free Joint Multi (FJM) A single answer for multiple zones. More comfort with less. This powerful unit supports two to five indoor units for multi-zone control with one outdoor unit. It s also available

More information

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control... MCAC-UTSM-2008-11 Contents Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units... 88 Part 4 Installation... 127 Part 5 Control... 136 The specifications, designs, and information

More information

Chilled Water System Solution

Chilled Water System Solution All Product Catalogue AP-MSM-07A Chilled ater System Solution Engineered for flexibility and performance. CONTENTS: Chilled ater System Solution McQuay Offers ; Comprehensive Solution... 2 In Air Conditioning

More information

Samsung 360 Cassette, Single Zone, Split System

Samsung 360 Cassette, Single Zone, Split System Job Name Purchaser Submitted to Unit Designation Location Engineer Reference Schedule # Approval Page 1 of 5 Construction Specifications Model Indoor Unit Model Number Outdoor Unit Model Number Nominal

More information

FAN COILS wall mounted

FAN COILS wall mounted SERVICE MANUAL FAN COILS wall mounted SF-51H, SF-68H, SF-85H PRODUCT MODELS LIST Model Name Cooling Capacity (W) Product Code Air Flow (m 3 /h) Power Supply (V,Ph,Hz) Remarks SF-51H 2700 EM55001260 550

More information

SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series

SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series FSKMIF-71AE2-EU FSKMIF-91AE2-EU FSKIF-121AE2-EU FSKMI-181AE2-EU FSLMIF-71AE2 FSLMIF-91AE2 FSLIF-121AE2 FSLMI-180AE2

More information

ECOELEGANT SERIES INSTALLATION AND OPERATION MANUAL

ECOELEGANT SERIES INSTALLATION AND OPERATION MANUAL ECOELEGANT SERIES INSTALLATION AND OPERATION MANUAL HWN-EC SERIES AERTESI srl Via della tecnica 6 35020 Conselve- PD ITALY www.aertesi.com NA version 2.1 Revised: Feb. 17, 2014 AER.MIU.HWNEC.GB.01.04/14

More information

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS Series HEAT PUMP PEH-7, 8, PEH-7 PEH-8 PEH- Cooling capacity () 18.8 22.0 28.8 Heating capacity () 19.4 22.0 28.8 High Efficiency, Powerful Heating and Cooling

More information

Engineering Data Book

Engineering Data Book 40VMC Compact 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs

More information

CASSETTE DUCT TYPE FLOOR CEILING. Light Commercial 18K BTU - 48K BTU

CASSETTE DUCT TYPE FLOOR CEILING. Light Commercial 18K BTU - 48K BTU CASSETTE DUCT TYPE FLOOR CEILING Light Commercial 18K BTU - 48K BTU 1-to-1 COMMERCIAL SERIES About our products The Tosot 1-to-1 commercial series of Air Conditioners was designed for applications where

More information

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56 Product Data INDUSTRY LEADING FEATURES / BENEFITS AN INEXPENSIVE AND

More information

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that

More information

R-410A. Ozone Friendly Refrigerant. Variable Compressor Speed Ductless Split Systems. Featuring:

R-410A. Ozone Friendly Refrigerant. Variable Compressor Speed Ductless Split Systems. Featuring: Ozone Friendly Refrigerant Variable Compressor Speed Ductless Split Systems Featuring: Ozone Friendly Refrigerant Variable Compressor Speed Technology IAQ Catechin Plus Air Purifying System 13 to 17 SEER

More information

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES turn to the experts SM R 410A DC INVERTER LIGHT COMMERCIAL SERIES DC Inverter Technology More Economical Energy Efficient Once indoor air temperatures reach your desired levels, inverter driven air-conditioners

More information

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy

More information

INVERTER Y SINGLE SPLIT SERIES II

INVERTER Y SINGLE SPLIT SERIES II TECHNICAL MANUAL -0005 Supercedes -0004 INVERTER Y SINGLE SPLIT SERIES II Models: M5CKY28ER M5CCY28CR M5CMY28ER M5CKY40ER M5CCY38CR M5CMY40ER M5CKY50ER M5CCY50CR M5CMY50ER M5CCY60CR M5CMY62CR Table of

More information

Owner s Manual TABLE OF CONTENTS

Owner s Manual TABLE OF CONTENTS 40GVC / 38GVC 40GVQ / 38GVQ High---Wall Ductless plit ystem izes 009 --- 024 Owner s Manual TABLE OF CONTENT PAGE AFETY PRECAUTION... 2 GENERAL... 2 INDOOR UNIT PART NAME... 3 REMOTE CONTROL PART NAME...

More information

Engineering Data Book

Engineering Data Book 40VMF 4-Way Cassette Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without

More information

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE

HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE HIGH EFFICIENCY MULTI-ROOM DUCTLESS SYSTEMS UP TO 5 ZONE GREE Multi 21 systems, with inverter technology, are some of today s most advanced ductless split heat pumps. Providing both cooling and heating

More information

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette Leading edge reverse cycle air conditioning Ducted and ceiling cassette Seeley International never stops striving to innovate and build the world s most energy efficient heaters and air conditioners. The

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

R22 AIR COOLED HIGH STATIC DUCTED SPLIT SYSTEM. Single & Double Skin Evaporator Units. Cooling Capacity : 80 to 750 MBH

R22 AIR COOLED HIGH STATIC DUCTED SPLIT SYSTEM. Single & Double Skin Evaporator Units. Cooling Capacity : 80 to 750 MBH R22 IR COOLED HIGH STTIC DUCTED SPLIT SYSTEM Single & Double Skin Evaporator Units Cooling Capacity : 80 to 750 MBH Innovative Outstanding DESIGN & PERFORMNCE IR COOLED CONDENSING UNITS SYSTEM FETURES

More information

All Product Catalogue

All Product Catalogue All Product Catalogue AP-MIY-13 Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information,

More information

Brief exposure to greenery in urban environments can relieve stress levels and your well-being.

Brief exposure to greenery in urban environments can relieve stress levels and your well-being. AVO+ / P1 FORESTO nature breeze Forest air doesn't just feel fresher and better - inhaling clean air actually improve your immune system. Brief exposure to greenery in urban environments can relieve stress

More information

AIR CONDITIONERS, HEATING & COOLING for your home

AIR CONDITIONERS, HEATING & COOLING for your home AIR CONDITIONERS, HEATING & COOLING for your home SLIM CONCEALED CEILING UNIT air to air heat pumps www.daikin.eu FDXS-E FDXS-C COMFORTABLE AIR, THE WHOLE YEAR THROUGH A comfortable living space provides

More information

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS 40MB*D Ducted Style Ductless System Sizes 09 to 48 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PARTS LIST... 3 DISPLAY PANELS... 4 FUNCTION BUTTONS... 5 REMOTE CONTROL...

More information

Fan Coil Range HYDRONIC TERMINALS

Fan Coil Range HYDRONIC TERMINALS Fan Coil Range HYDRONIC TERMINALS This document can be subjected to variations. Descriptions, performance data, images and diagrams are indicative only. For further information contact Climaveneta Comunications/Marketing

More information

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG Spring 2017 Edition BRYANT VRF ADVANTAGES IT TAKES an Efficient Solution...1 What is Variable Refrigerant Flow (VRF)...1 Simultaneous Heating & Cooling...1

More information

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP www.mitsubishielectric.ca P-SERIES The Attraction of Being Untraditional Mr. Slim P-Series is the ductless solution for demanding environments that

More information

Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15

Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15 Midea VRF (V+) V+S (Heat Pump) V+i (Individual) (Heat Pump) V+R (Heat Recovery) MVRF 05/5 Midea CAC (MCAC) As a key subsidiary of the Midea Group, the Midea Central Air Conditioner (MCAC) business unit

More information

LV Series. SEER 15+ Concealed Built in Heat Pump

LV Series. SEER 15+ Concealed Built in Heat Pump LV Series SEER 15+ Concealed Built in Heat Pump EXPERTISE AND INNOVATION Daikin s slim duct systems offer a built in solution with the benefits of duct free technology. Installed similar to a traditional

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

Air Conditioner CONTENTS

Air Conditioner CONTENTS ORDER NO. MAC0509068C2 Air Conditioner CS-F24DD1E5 CU-B24DBE5 CS-F28DD1E5 CU-B28DBE5 CS-F28DD1E5 CU-B28DBE8 CS-F34DD1E5 CU-B34DBE5 CS-F34DD1E5 CU-B34DBE8 CS-F43DD1E5 CU-B43DBE8 CS-F50DD1E5 CU-B50DBE8 CONTENTS

More information

Variable Refrigerant Flow

Variable Refrigerant Flow Variable Refrigerant Flow Two-pipe Heat Recovery and Heat Pump Systems Heat Recovery Single-chassis Design Heat Pump Modular Design Table of Contents Carrier VRF Advantages 2 Revolutionary Design 3 Advanced

More information