Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Size: px
Start display at page:

Download "Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland"

Transcription

1 Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Paper ID 0141 ISBN: Prediction of exhaust gas stagnation in common corridor of apartments with gas water heater Takuro Nakamura 1,*, Takashi Kurabuchi 1 1 Tokyo University of Science, Tokyo, Japan * tenni.taku.tennis@gmail.com SUMMARY Gas water heaters are usually installed in common hallways of Japanese apartments. When the exhaust gas remains in the common hallway, there is a possibility that will leak into the living room through the air supply opening for ventilation. This can harm the health of the resident. In order to understand this problem, experiments were conducted using a full-scale common hallways model, and an analysis was performed using CFD(computational fluid dynamics). It is difficult to predict the diffusion of the exhaust gas injected at 15-. Therefore, we propose a visualization measurement of exhaust gas. The CFD result shows a good agreement with the retention state of the common hallways where the gas water heater is installed. The installable position of the gas water heater was explained by a case study. KEYWORDS Gas water heaters, CFD analysise, jet, ventilation 1 INTRODUCTION Gas water heaters are usually installed in the common hallways of Japanese apartment buildings. (Fig.1)When the exhaust gas stagnates in a corridor, it always leaks into the living room of an apartment through the air supply opening for ventilation. As a result, there is a possibility of the health of the resident being adversely affected. Therefore, it is important from the viewpoint of maintaining a healthy environment of the common hallways to determine the retention characteristics of the exhaust gas of a gas water heater. In order to understand the problem of exhaust gas stagenation, experiments were conducted using a fullscale hallway model and CFD analysis was performed. In addition, the insight gained from the findings of this research was utilized for formulating the installation standards for gas equipment in Japan. Fig. 1. Hallway of apartment buildings in Japan

2 2 METHODS 2.1 Experiment Assuming a case in which there is no opening for ventilation of common hallways in front of the gas water heater, an oblique exhaust type gas water heater equipped with a 15- deflection adapter was reproduced in the full-scale experiment model of a common hallways. For the measurements, an air supply opening for ventilation was set in the full-scale experiment model, duct suction was conducted to simulate the air flowing into the room, and the concentration of CO2 in the air was measured. The measured CO2 concentration value of 1,000 ppm was chosen as the reference value of Building Environmental Sanitation Control Standard. In Fig. 2, the measurement hallway with different setting positions of the air supply opening for ventilation are shown. For the hot water supply mode, the operation of the gas water heater reproduced the peak hour (19:-30-20:-30) of hot water usage time including simultaneous use in the kitchen from the hot water bathtub. (Fig. 3) When the corridor width was m in the experiment model as shown in Fig.2, the gas appliance was moved by a distance of m from the center of the corridor (hereinafter referred to as the shift distance of the gas water heater). In each case (Fig.2), a laser light sheet was irradiated on the cross section near the opening, and the exhaust jet flow was visualized when it passed through the-cross section. (Fig. 4) Move to the screen side by 1.0 m Move to the screen side by 1.25 m Move to the screen side by 1.0 m Move to the screen side by 1.25 m 15 deflection 15 deflection Fig.2 Measurement hallway and setting positions for the air supply opening for ventilation Gas Consumption [m 3 /h] Filling bathtub with hot water (15L/m) Shower (10L/m) Shower (10L/m) Gas water heater HD camera Kitchen (5L/m) Kitchen (5L/m) Kitchen (5L/m) ,200 1,800 2,400 3,000 3,600 19:30 Time [s] Heating (5000kcal/h) 20:30 Fig.3 Gas water heater operation method Smoke generating device Sheet laser Inside corridor section view Front view Fig.4 Visualization method 2.2 CFD analysis To explore the shift distance of the gas water heater, a case study was conducted via CFD analysis and the positional relationship between the jet and screen was examined. The common hallway model with a width of 2.0 m in the experiments was chosen as the CFD analysis model. (Fig. 5) The CFD analysis conditions are presented in Table 1. For the boundary condition of the gas water heater, we used the actual value measured with a gas water heater without the deflection adapter and operating as a hot water output at 15 L/min. For the outside air condition, we used the actual measurement value obtained with experiment No.1 -with T1.00(refer Fig. 2). The CFD analysis area is shown in Fig.5. The common hallway and air outlet of the gas water heater were reproduced in a large space. We also

3 assumed an inflow of fresh outside air into the large space and modeled this real phenomenon. In this research, to reproduce the exhaust properties in more detail, as shown in Fig.6, the deflection adapter for the air outlet of the gas water heater was modeled and analyzed. The four cases studied are shown in Fig. 7,and Table 2. The shift distance of the gas water heater was varied from 1.00 m to 1.75 m at an interval of 0.25m. In each case, the CO2 concentration extraction point is indicated by a black circle in Fig. 7 at the center of the ceiling. Gas water heater Outlet air outlet of the gas water heater 10,000mm Inlet the deflection adapter of air outlet of the gas water heater Fig.5 CFD analysis model 1,00m 1,25m No.1 No.2 1,50m 1,75m No.5 No.6 Fig.7 Case study model Fig.6 Deflection adapter of the gas water heater Table1 CFD analysis conditions boundary condition item CFD code Turbulence model Analysis area air outlet of the gas water heater outlet Difference scheme Table2 Case study model Details Code C standard k-ε model (m) velocity,temperature, CO 2 density based on actual measurement Flow distribution outlet Secondary windward accuracy Width of common Measurement point(black dot) hallway(m) 2 common hallway center 3 RESULTS 3.1 Experimental results Fig. 8 shows the experimental results obtained from the measurement of CO2 concentration at different air supply opening positions. At the points T0.25 and T0.50 on the exhaust flow path, the CO2 concentration is higher than other air supply opening locations, however, in all the cases it does not exceed the reference value of 1,000 ppm. In the visualization experiments, when comparing the shift distance of the gas water heater, the ceiling CO2 concentration is higher when the gas water heater shift distance is 1.25 m (No.2 and 4) rather than 1.00 m (No.1 and 3). With respect to this factor, the visualization experimental results in Fig. 9 show that when the shift distance of the gas water heater is 1.00 m (No.1 and 3), the jet flow does not contact the screen, but passes through the opening. However, when it is 1.25 m (No.2 and 4), we observe that the jet is in contact with the screen.

4 Air supply opening CO 2 density(ppm) 1,200 1, U0.00 U0.25 T0.00 T0.25 T0.50 T0.75 T1.00 NO NO NO NO Air supply opening position/name Fig.8 Experimental results from the measurement of CO2 concentration at different air supply opening positions No.1 Opening cross-section in hallway No.2 Opening cross-section in hallway No.3 Opening cross-section in hallway No.4 Opening cross-section in hallway Fig.9 Results of the visualization experiments 3.2 CFD analysis results Comparison of CO2 concentration at the extraction point Fig. 10 shows the CO2 concentration at the extraction point. It was confirmed from the CFD analysis that consistency was almost obtained from experiment No. 1. When the shift distance of the gas water heater increases, the CO2 concentration increases. In particular, when the gas water heater shifting distance is m, the CO2 concentration is 2,200 2,900 ppm, and when the former is m, the latter rapidly increases. Position relationship between jet and screen

5 Fig. 11 shows the CO2 concentration distribution in the exhaust port high section (H = 2.2 m) for each shift distance of the gas water heater. Between 1.00 and 1.25 m, the jet passes through the opening and is released to the external space, but between 1.50 and 1.75 m, the jet flow contacts the screen and CO2 remains concentrated in the corridor. Air supply opening CO 2 density (ppm) m 1.25m 1.50m 1.75m shift distace of the gas water heater Fig.10 CO2 concentration at the extraction point Gas water heater Outlet cross section CO 2 density Fig.11 CO2 concentration distribution in the exhaust port high section (H = 2.2 m) 4 DISCUSSION An oblique exhaust type gas water heater was installed in a common corridor having a general opening area to ascertain the state of exhaust gas retention. Even when the shift distance of

6 the gas water heater was 1.25 m, the CO2 concentration at the ventilation opening did not exceed the reference value. In addition, we investigated the shift distance of the gas water heater via CFD analysis, and found that when it is greater than 1.25 m, the jet may come into contact with the screen and remain in the corridor. For these reasons, it can be concluded that even if an oblique exhaust type gas water heater is provided with a wall on the front side, if the jet exhaust is released toward the opening, it is possible to install it with a shift distance of approximately 0.25 m. 5 CONCLUSIONS With regard to the criteria for installing an oblique exhaust type gas water heater, this study explained the installable position of the gas water heater and location of the air supply opening. 6 REFERENCES [1]Installation standards and practical guidelines for gas appliances: Japan Gas Equipment Inspection Association [2] JIS S 2071, Standard use conditions, standard acceleration mode and test conditions for domestic gas and oil water heater, 2008 [3] T.Nakamura et al : Installation standards of gas water heater in a hallway of an apartment buildings -CFD aimed analysts of Diffusion Characteristic of Exhaust Air from Gas Equipments- (SHASE Japan 2016)

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Paper ID 0188 ISBN: 978-83-7947-232-1 Dispersion of pollutants released at floor level under three types of heating systems: A CFD study. Laura

More information

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING

STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING STACK EFFECT IN LIGHT WELL OF HIGH RISE APARTMENT BUILDING H. Kotani, R. Satoh, T. Yamanaka Dept. of Architectural Engineering, School of Engineering, Osaka University, Osaka, Japan ABSTRACT The purpose

More information

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan INDOOR CLIMATE DESIGN BASED ON FEEDBACK CONTROL OF HVAC COUPLED SIMULATION OF CONVECTON, RADIATION, AND HVAC CONTROL FOR ATTAINING GIVEN OPERATIVE TEMPERATURE Shuzo Murakami, Shinsuke Kato, and Taeyeon

More information

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments Jason Huczek a, Marc Janssens a, Kentaro Onaka b, Stephen Turner c a SwRI, 6220 Culebra Road, San

More information

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM Mingjie Zheng Research Laboratory, SANKO AIR CONDITIONING CO., LTD. Nagoya, 450-0003, JAPAN ABSTRACT In large

More information

Numerical Simulation of Ventilation Efficiency in Commercial Kitchen

Numerical Simulation of Ventilation Efficiency in Commercial Kitchen Numerical Simulation of Ventilation Efficiency in Commercial Kitchen Yasushi Kondo 1, Shin-ichi Akabayashi 2, Osamu Nagase 3 and Akihiko Matsuda 4 1 Dept of Architecture, Musashi Institute of Technology,

More information

Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement

Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement Daisuke Ogura 1, Masahide Inuzuka 2, Shuichi Hokoi 1, Takeshi Ishizaki 2, Hiroyuki Kitahara

More information

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room Y. Momoi 1, K. Sagara 1, T. Yamanaka 1 and H. Kotani 1 1 Osaka University, Graduate School of Eng., Dept.

More information

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION

EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION Eighth International IBPSA Conference Eindhoven, Netherlands August 11-14, 2003 EXPERIMENTAL AND CFD STUDIES ON SURFACE CONDENSATION Liu Jing 1, Yoshihiro Aizawa 2, Hiroshi Yoshino 3 1 School of Municipal

More information

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Healthy Buildings 217 Europe July 2-5, 217, Lublin, Poland Paper ID 95 ISBN: 978-83-7947-232-1 Verification of gymnasium designed by high thermal insulation considering elderly people in disaster Koki

More information

Comparison of Thermal Comfort by Radiant Heating and Convective Heating

Comparison of Thermal Comfort by Radiant Heating and Convective Heating Journal of Engineering, Project, and Production Management 2015, 5(1), 26-35 Comparison of Thermal Comfort by Radiant Heating and Convective Heating Shigeru Imai 1 and Shoichi Kojima 2 1 MSc Student, Department

More information

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE 1 RU ZHOU, 2 WEI ZHANG 1 School of Urban Construction and Safety Engineering, Nanjing University of Technology, Nanjing

More information

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Paper ID 0320 ISBN: 978-83-7947-232-1 The Analysis of the Air Velocity Distribution above the Trench Heater with Natural Convection Mariusz

More information

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates Zhou Y., Fei Y.*, Hu S. Q. Nanjing Tech University, College of Fire Safety Science and Engineering &

More information

STUDY ON THE EFFECTIVENESS OF AIR-CONDITIONING AND VENTILATION SYSTEMS BY CFD ANALYSIS IN HOUSES

STUDY ON THE EFFECTIVENESS OF AIR-CONDITIONING AND VENTILATION SYSTEMS BY CFD ANALYSIS IN HOUSES STUDY ON THE EFFECTIVENESS OF AIR-CONDITIONING AND VENTILATION SYSTEMS BY CFD ANALYSIS IN HOUSES Hiroko Kaji 1, Shin-ichi Akabayashi 1, and Jun Sakaguchi 2 1 Division of Science and Technology, Graduate

More information

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger Toke Rammer Nielsen, Associate Professor, Department of Civil Engineering, Technical University of Denmark; trn@byg.dtu.dk

More information

Impact of heat load distribution and strength on airflow pattern in rooms with exposed chilled beams

Impact of heat load distribution and strength on airflow pattern in rooms with exposed chilled beams Impact of heat load distribution and strength on airflow pattern in rooms with exposed chilled beams Risto Kosonen 1, Arsen Melikov 2, Boryana Yordanova 2 and Lyuben Bozkhov 2 1 Halton Oy 2 International

More information

Healthy Buildings 2017 Europe July 2 5, 2017, Lublin, Poland. Evaluation of task air conditioning system with convection, conduction, and radiation

Healthy Buildings 2017 Europe July 2 5, 2017, Lublin, Poland. Evaluation of task air conditioning system with convection, conduction, and radiation Healthy Buildings 2017 Europe July 2 5, 2017, Lublin, Poland Paper ID 0009 ISBN: 978-83-7947-232-1 Evaluation of task air conditioning system with convection, conduction, and radiation Misa Imazu 1,*,

More information

Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings

Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings - 1 - Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings Mamoru Hamada, Living Environment Systems Laboratory, Mitsubishi Electric Co., Kamakura, Kanagawa, Japan Naomichi

More information

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li

Aalborg Universitet. Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li Aalborg Universitet Diffuse Ceiling Inlet Systems and the Room Air Distribution Nielsen, Peter Vilhelm; Jensen, Rasmus Lund; Rong, Li Published in: Clima 2010 : 10th Rehva World Congress Publication date:

More information

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen * Journal of Environmental Protection, 2013, 4, 638-646 http://dx.doi.org/10.4236/jep.2013.46073 Published Online June 2013 (http://www.scirp.org/journal/jep) The Research of Performance Comparison of Displacement

More information

Case Study 1 Underground Car Park

Case Study 1 Underground Car Park Case Study 1 Underground Car Park Dorota Brzezińska 1, Janusz Paliszek 2, Piotr Smardz 2, Renata Ollesz 1, Karol Kaczor 2 1 Lodz University of Technology, GRID - Lodz, 2 INBEPO Wroclaw, Poland Building

More information

The Experimental Validation of Numerical Modeling of the Air Distribution in the Indoor Ice Rink Arena

The Experimental Validation of Numerical Modeling of the Air Distribution in the Indoor Ice Rink Arena Proceedings of the World Congress on Mechanical, Chemical, and Material Engineering (MCM 2015) Barcelona, Spain July 20-21, 2015 Paper No. 276 The Experimental Validation of Numerical Modeling of the Air

More information

A STUDY ON THE DEVELOPMENT OF A DEODORIZATION UNIT FOR THE TOILET BIDET

A STUDY ON THE DEVELOPMENT OF A DEODORIZATION UNIT FOR THE TOILET BIDET A STUDY ON THE DEVELOPMENT OF A DEODORIZATION UNIT FOR THE TOILET BIDET I. S. Hwang and Y. L. Lee Department of Mechanical Engineering, Kongju National University, Korea E-Mail: ylee@kongju.ac.kr ABSTRACT

More information

PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR

PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR PERFORMANCE EVALUATION OF THE MINIATRIZED CATALYTIC COMBUSTION TYPE HYDROGEN SENSOR Hiroshi Miyazaki 1, Hiromasa Tanjyoh 2, Kengo Suzuki 3, Tomoaki Iwami 4 1 New cosmos electric, co., ltd., Osaka, 543-0036,

More information

AMOUNT OF MOISTURE PRODUCTION AND FIELD MEASUREMENT IN DRESSING ROOM

AMOUNT OF MOISTURE PRODUCTION AND FIELD MEASUREMENT IN DRESSING ROOM AMOUNT OF MOISTURE PRODUCTION AND FIELD MEASUREMENT IN DRESSING ROOM Yoshihiro Aizawa 1, Shin-ichi Tanabe 2, Kanako Yokoo 2, Kentaro Watanabe 3, and Hideki Amai 4 1 Tokyo Gas Co. Ltd., Tokyo, Japan 2 Waseda

More information

September 11, 2012 Ministry of Economy, Trade and Industry

September 11, 2012 Ministry of Economy, Trade and Industry Data 2 Final Report by Heat Pump Water Heater Evaluation Standards Subcommittee, Energy Efficiency Standards Subcommittee of the Advisory Committee for Natural Resources and Energy September 11, 2012 Ministry

More information

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN , Volume 6, Number 4, p.248-254, 04 RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN C.L. Choi Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China ABSTRACT Water

More information

An Analysis of Compartment Fire and Induced Smoke Movement in Adjacent Corridor

An Analysis of Compartment Fire and Induced Smoke Movement in Adjacent Corridor 2C-1 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea An Analysis of Compartment Fire and Induced Smoke Movement in Adjacent Corridor Soo-Young Kim *, Eung-Sik

More information

Development of Large Size Hybrid Fan

Development of Large Size Hybrid Fan Technical Paper Toshihiko Nishiyama Kengo Koshimizu Keiichi Inaba A lot of small fans with three-dimensional, wide chord length, forward swept figure, and/or shroud ring have been developed and manufactured

More information

PERFORMANCE ANALYSIS OF GROUND SOURCE HEAT PUMPS FOR DOMESTIC HOT WATER SUPPLY IN THE LOW ENERGY HOUSE AND ITS APPLICATION

PERFORMANCE ANALYSIS OF GROUND SOURCE HEAT PUMPS FOR DOMESTIC HOT WATER SUPPLY IN THE LOW ENERGY HOUSE AND ITS APPLICATION - 1 - PERFORMANCE ANALYSIS OF GROUND SOURCE HEA PUMPS FOR DOMESIC HO WAER SUPPLY IN HE LOW ENERGY HOUSE AND IS APPLICAION akao Katsura, Fujiwara Environmental Science Institute Ltd, Sapporo, Japan Katsunori

More information

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Siddharth Jain, Yogesh Deshpande, Atul Bokane, Arun Kumar Santharam, and Deepak Babar, Halliburton Abbreviations: Computational

More information

AMOUNT OF MOISTURE PRODUCED INSIDE BATHROOM AND APPURTENANT CHANGING ROOM

AMOUNT OF MOISTURE PRODUCED INSIDE BATHROOM AND APPURTENANT CHANGING ROOM AMOUNT OF MOISTURE PRODUCED INSIDE BATHROOM AND APPURTENANT CHANGING ROOM K. Yokoo 1, S. Tanabe 1, Y. Aizawa 2, K. Inagaki 2, D. Kawamata 2, H. Amai 1, K. Watanabe 1, and T. Nishimasu 1 1 Waseda University,

More information

Leakage of Mildly Flammable Refrigerants into a Room

Leakage of Mildly Flammable Refrigerants into a Room Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 214 Leakage of Mildly Flammable Refrigerants into a Room Hiroaki Okamoto The

More information

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering Analysis of the influence of open door size on fire smoke diffusion law in protective engineering Abstract Zheli Xing a, Jinfeng Mao b, Chaofeng Li c and Jin Zhou d PLA University of Science and Technology,

More information

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings Justin A. Geiman, Noah L. Ryder Fire & Risk Alliance, Rockville, MD, USA André W. Marshall Custom Spray Solutions, Silver Spring,

More information

American Society of Heating, Refrigerating and Air-Conditioning Engineers

American Society of Heating, Refrigerating and Air-Conditioning Engineers Flow Pattern and Thermal Comfort in Office Environment with Active Chilled Beams Journal: American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Manuscript ID: Draft Publication:

More information

STUDY FOR SAFETY AT A RELATIVELY SHORT TUNNEL WHEN A TUNNEL FIRE OCCURRED

STUDY FOR SAFETY AT A RELATIVELY SHORT TUNNEL WHEN A TUNNEL FIRE OCCURRED - 133 - STUDY FOR SAFETY AT A RELATIVELY SHORT TUNNEL WHEN A TUNNEL FIRE OCCURRED Y. Mikame 1,2, N. Kawabata 1, M. Seike 1, M. Hasegawa 1 1 Kanazawa University, Japan 2 Metropolitan Expressway Company

More information

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS

COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS COMPARISON OF THE THERMAL ENVIRONMENT IN ROOMS WITH CHILLED BEAM AND RADIANT PANEL SYSTEMS Risto Kosonen, Panu Mustakallio Arsen Melikov 2, Marcin Duszyk 2 Oy Halton Group Ltd., Helsinki, Finland. 2 International

More information

Improving Single-Sided Room Ventilation by Using a Ceiling Fan

Improving Single-Sided Room Ventilation by Using a Ceiling Fan Improving Single-Sided Room Ventilation by Using a Ceiling Fan Ahmed Rizk, Mustafa Elwan, Ehab Mouris To cite this version: Ahmed Rizk, Mustafa Elwan, Ehab Mouris. Improving Single-Sided Room Ventilation

More information

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect A Numerical Investigation on the Effect of Operation Control of a Multi-Split Air-Conditioning System on Indoor Thermal Environment H. Matsunaga 1,*, S. Iizuka 1, M. Okumiya 1, G. Yoon 2, and H. Niwa 3

More information

HEAT REMOVAL TESTS FOR THE HIGH PERFORMANCE VAULT STORAGE SYSTEM OF SPENT NUCLEAR FUEL

HEAT REMOVAL TESTS FOR THE HIGH PERFORMANCE VAULT STORAGE SYSTEM OF SPENT NUCLEAR FUEL HEAT REMOVAL TESTS FOR THE HIGH PERFORMANCE VAULT STORAGE SYSTEM OF SPENT NUCLEAR FUEL M. Oda*, M. Shimizu*, N. Kumagai*, H. Kanai**, M. Tanabe** *Nuclear Fuel Cycle Group, Power & Industrial Systems R&D

More information

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION - 165 - CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION Wojciech Węgrzyński, Grzegorz Krajewski, Paweł Sulik Fire Research Department, Building Research Institute (ITB), Poland ABSTRACT

More information

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics Journal of Electronics and Information Science (2018) 3: 22-33 Clausius Scientific Press, Canada Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics Lian-Tuu Yeh, ASME Fellow

More information

Evaluation on Residential Energy Efficiency Programs Using the City-Scale End-Use Simulation Model

Evaluation on Residential Energy Efficiency Programs Using the City-Scale End-Use Simulation Model Evaluation on Residential Energy Efficiency Programs Using the City-Scale End-Use Simulation Model Yoshiyuki Shimoda, Osaka University Takuro Fujii, Osaka University Takao Morikawa, Osaka University Minoru

More information

Aspirating Gas Detection CFD Modelling Predicts Application Performance

Aspirating Gas Detection CFD Modelling Predicts Application Performance Aspirating Gas Detection CFD Modelling Predicts Application Performance Yun Jiang Xtralis, Bentleigh East, Australia Claudio Groppetti Xtralis, Avon, MA, USA Abstract Historically gas detection has utilized

More information

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way 1 CHAPTER I INTRODUCTION In the modern life, electronic equipments have made their way in to practically every part, which is from electronic gadgets to high power computers. Electronic components have

More information

Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products

Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products Bakalis S.*, Giannakourou M.C. and Taoukis P. School of Chemical Engineering, National Technical

More information

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE Conference on Sustainable Building South East Asia, -7 November 27, Malaysia GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE G. REIMANN IEN Consultants,

More information

Keywords: slope stability, numerical analysis, rainfall, infiltration. Yu. Ando 1, Kentaro. Suda 2, Shinji. Konishi 3 and Hirokazu.

Keywords: slope stability, numerical analysis, rainfall, infiltration. Yu. Ando 1, Kentaro. Suda 2, Shinji. Konishi 3 and Hirokazu. Proceedings of Slope 25, September 27-3 th 25 SLOPE STABLITY ANALYSIS REGARDING RAINFALL-INDUCED LANDSLIDES BY COUPLING SATURATED-UNSATURATED SEEPAGE ANALYSIS AND RIGID PLASTIC FINITE ELEMENT METHOD Yu.

More information

Safety research of A2L/A3 refrigerants and risk assessment in Japan. Eiji Hihara The University of Tokyo

Safety research of A2L/A3 refrigerants and risk assessment in Japan. Eiji Hihara The University of Tokyo Safety research of A2L/A3 refrigerants and risk assessment in Japan Eiji Hihara The University of Tokyo 1 Trade-off relationship between GWP and flammability To reduce the emission of greenhouse gases

More information

Minimal Invasive Ventilations Systems with Heat Recovery for Historic Buildings

Minimal Invasive Ventilations Systems with Heat Recovery for Historic Buildings Minimal Invasive Ventilations Systems with Heat Recovery for Historic Buildings Rainer Pfluger #1, Kai Längle #2 # Energy Efficient Buildings, University of Innsbruck Technikerstr. 13, 6020 Innsbruck,

More information

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling Aleksandra Cichoń,*, Anna Pacak, Demis Pandelidis, and Sergey Anisimov Department of

More information

Considerations in the Design of Smoke Management Systems for Atriums

Considerations in the Design of Smoke Management Systems for Atriums Construction Technology Update No. 48 Considerations in the Design of Smoke Management Systems for Atriums by G.D. Lougheed This Update discusses the use of an engineered approach to the design of smoke

More information

Indoor Climate Control Effect of AAC Panel Heat Capacity Experimental rooms and simulations with three structural materials

Indoor Climate Control Effect of AAC Panel Heat Capacity Experimental rooms and simulations with three structural materials Indoor Climate Control Effect of AAC Panel Heat Capacity Experimental rooms and simulations with three structural materials YUKO TSUKIYAMA 1, NOBUYUKI SUNAGA 2, AKIKO SUZUKI 2, TAMAKI FUKAZAWA 2, YOSUKE

More information

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs 1 ABSTRACT Noureddine Benichou and Ahmed H. Kashef * Institute for Research in Construction National Research Council of Canada

More information

HME09 NATURAL VENTILATION

HME09 NATURAL VENTILATION HME09 NATURAL VENTILATION Requirement Summary This measure can be claimed when two conditions are met. The first one is the room depth to ceiling height ratio and the proportion of openings required for

More information

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2008 Performance Evaluation and Design Optimization of Refrigerated Display

More information

Tunnel Fire Dynamics and Evacuation Simulations

Tunnel Fire Dynamics and Evacuation Simulations Tunnel Fire Dynamics and Evacuation Simulations James Priest, PhD & James Niehoff DGS-SEE Seminar on Fire Protection for Physics Research Facilities 7 & 8 October 2015 Introduction (Background) Presentation

More information

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe Brig Gen Md. Lutfor Rahman, Sumaiya Nawrin, Rasel A Sultan Department of Mechanical Engineering, Military Institute

More information

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

International Forum on Energy, Environment Science and Materials (IFEESM 2015) The Comparison and Analysis of Humidity Environment between Floor and Ceiling Radiant Cooling Systems that Combined with Displacement Ventilation Kai SUN 1 a *, Chuan-hui ZHOU 1 1 College of Urban Construction,

More information

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Mold Infestation in Buildings of Warm Humid Climate Case Studies

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Mold Infestation in Buildings of Warm Humid Climate Case Studies Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Paper ID 0039 ISBN: 978-83-7947-232-1 Mold Infestation in Buildings of Warm Humid Climate Case Studies Chin Peng Foo *, Poh San Tee, Chung Wan

More information

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant M. Honma, T. Tamura, Y. Yakumaru and F. Nishiwaki Matsushita Electric Industrial Co., Ltd. Living Environment

More information

Faculty of Mechanical and Manufacturing Engineering Universiti Tun Hussein Onn Malaysia Pt. Raja, Batu Pahat, Johor, MALAYSIA

Faculty of Mechanical and Manufacturing Engineering Universiti Tun Hussein Onn Malaysia Pt. Raja, Batu Pahat, Johor, MALAYSIA CFD Analysis of Industrial Multi-Stage Impeller in Stirred Tank with Fractal Pattern Baffled and Impeller MANSHOOR Bukhari 1, a, MDSAUFI Muhammad Faiq 1, b, ZAMAN Izzuddin 1, c, and KHALID Amir 1, d 1

More information

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat Abstract Axial flow fans, while incapable of developing high pressures, they are well suitable for handling large volumes of air at relatively

More information

A Study on Anti-Loosening Characteristics of Different 3/8 BSW Threaded Fasteners

A Study on Anti-Loosening Characteristics of Different 3/8 BSW Threaded Fasteners 409 14 th National Conference on Machines and Mechanisms (NaCoMM09), NIT, Durgapur, India, December 17-18, 2009 NaCoMM-2009-MMRAIAKM19 A Study on Anti-Loosening Characteristics of Different 3/8 BSW Threaded

More information

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability Proceedings of the International Conference in Dubrovnik, 15-16 October 2015 FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability Johan Anderson a, Lars Boström a, Robert Jansson

More information

developed, and parametric studies are conducted with the model. Based on the parameter study results, a dehumidification performance diagram is propos

developed, and parametric studies are conducted with the model. Based on the parameter study results, a dehumidification performance diagram is propos Evaluation of A Plate Desiccant Outdoor Air-conditioning System Utilizing Cogenerated Hot Water Using A Numerical Model T. Baba 1, B. Park 1 1, *1, and T. Nagai 1 Department of Architecture, Tokyo University

More information

Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel

Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel Available online at www.sciencedirect.com Procedia Engineering 52 ( 2013 ) 330 335 Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater

More information

Fire and smoke management in a uni-directional road tunnel for a congested traffic condition

Fire and smoke management in a uni-directional road tunnel for a congested traffic condition Fire and smoke management in a uni-directional road tunnel for a congested traffic condition Y Liu, J Munro Parsons Brinckerhoff Australia B Dandie Thiess Pty Ltd., Australia ABSTRACT Emergency smoke ventilation

More information

A study for a fire spread mechanism of residential buildings with numerical modeling

A study for a fire spread mechanism of residential buildings with numerical modeling Safety and Security Engineering IV 185 A study for a fire spread mechanism of residential buildings with numerical modeling C.-S. Ahn & J.-Y. Kim Fire Safety Research Division, Korea Institute of Construction

More information

Vertical Distribution of Air Temperatures in Heated Dwelling Rooms

Vertical Distribution of Air Temperatures in Heated Dwelling Rooms Vertical Distribution of Air Temperatures in Heated Dwelling Rooms Ondrej Sikula University of Technology Brno, Brno Corresponding email: sikula.o@fce.vutbr.cz SUMMARY The paper presents an experimental

More information

Keywords: ECM, suction tool, auxiliary electrode, current density, machining characteristics

Keywords: ECM, suction tool, auxiliary electrode, current density, machining characteristics Realization of Current Area Restriction in ECM Process by Electrolyte Suction Tool with Auxiliary Electrode Wataru Natsu 1, a *, Guixian Liu 1,2,b, and Saori Hizume 1,c 1 Tokyo University of Agriculture

More information

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland Paper ID 0232 ISBN: 978-83-7947-232-1 Experimental study of a novel dew point indirect evaporative cooler Wenhua Chen, Zhiwei Zhang, Jiayu Li,

More information

Optimisation of cooling coil performance during operation stage for improved humidity control

Optimisation of cooling coil performance during operation stage for improved humidity control Indoor Air 2008, 17-22 August 2008, Copenhagen, Denmark - Paper ID: 741 Optimisation of cooling coil performance during operation stage for improved humidity control S.C. Sekhar * and L.T. Tan National

More information

Numerical Simulation of Thermal Comfort Degree in Radiant Floor Cooling Room. Architecture, Beijing , China

Numerical Simulation of Thermal Comfort Degree in Radiant Floor Cooling Room. Architecture, Beijing , China Numerical Simulation of Thermal Comfort Degree in Radiant Floor Cooling Room Yanli Ren 1 ; Deying Li 2 ; Yufeng Zhang 1 1 School of Environment Science and Engineering, Tianjin University, Tianjin 300072,

More information

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia To cite this article: N A Malek

More information

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance #1 Jaydev S. Bade, #2 Dr. Nitin U. Korde 1 Department of Mechanical Engineering, Savitribai Phule

More information

Research on fire protection methods and a case study "Futurum"

Research on fire protection methods and a case study Futurum Available online at www.sciencedirect.com Procedia Engineering 40 (2012 ) 339 344 Steel Structures and Bridges 2012 Research on fire protection methods and a case study "Futurum" J. Outinen a *, J. Samec

More information

BR-BO Adopted June 1, Evacuation Safety Performance Evaluation Manual

BR-BO Adopted June 1, Evacuation Safety Performance Evaluation Manual BR-BO-07-01 Adopted June 1, 2000 Evacuation Safety Performance Evaluation Manual Article 1: Scope of Application This manual applies to the following types of performance evaluations: (1) Performance evaluations

More information

Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2

Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2 A CFD Analysis of Smoke Movement in Steel Industry Sheds Sandeep V. Lutade 1, Krunal Mudafale 2, Ranjan Kishore Mallick 3 1, 2 Mechanical Dept. Dr.Babasaheb Ambedkar College of Engineering and Research,

More information

Residential Building Walls and Environment in Amman, Jordan

Residential Building Walls and Environment in Amman, Jordan Int. J. of Thermal & Environmental Engineering Volume 3, No. 2 (211) 1-7 Residential Building Walls and Environment in Amman, Jordan S. J. Sulaiman*, N. Beithou Department of Mechanical Engineering, Applied

More information

An experimental study of the impact of tunnel suppression on tunnel ventilation

An experimental study of the impact of tunnel suppression on tunnel ventilation An experimental study of the impact of tunnel suppression on tunnel ventilation Yoon J. Ko and George Hadjisophocleous Civil and Environmental Engineering, Carleton University 1125 Colonel By Drive, Ottawa,

More information

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic Eighth International IBPSA Conference Eindhoven, Netherlands August 11-14, 2003 MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING Vladimír Zmrhal 1, Jan Hensen 2 and František Drkal 1 1

More information

A study of 4 liter toilet with new flushing technology

A study of 4 liter toilet with new flushing technology A study of 4 liter toilet with new flushing technology Kojiro Watari (1), Masayuki Otsuka (2), Satoshi Kitamura (3) 1 koujirou.watari@lixil.co.jp 2 dmotsuka@kanto-gakuin.ac.jp 3 satoshi.kitamura@lixil.co.jp

More information

Effects of Fan-Aspirated Radiation Shield for Temperature Measurement in Greenhouse Environment

Effects of Fan-Aspirated Radiation Shield for Temperature Measurement in Greenhouse Environment Original Article J. of Biosystems Eng. 37(4):245-251. (2012. 8) http://dx.doi.org/10.5307/jbe.2012.37.4.245 Journal of Biosystems Engineering eissn : 2234-1862 pissn : 1738-1266 Effects of Fan-Aspirated

More information

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV)

Internal flow Patterns of the Horizontal Heat Mode Closed-Loop Oscillating Heat Pipe with Check Valves (HHMCLOHP/CV) Research Journal of Applied Sciences, Engineering and Technology 5(3): 865-869, 2013 ISSN: 2040-7459; E-ISSN: 2040-7467 Maxwell Scientific Organization, 2013 Submitted: June 13, 2012 Accepted: July 09,

More information

EVALUATION ON PERFORMANCE OF PHOTOELECTRIC SMOKE DETECTORS IN THE ZONE DETECTION SYSTEM

EVALUATION ON PERFORMANCE OF PHOTOELECTRIC SMOKE DETECTORS IN THE ZONE DETECTION SYSTEM EVALUATION ON PERFORMANCE OF PHOTOELECTRIC SMOKE DETECTORS IN THE ZONE DETECTION SYSTEM Hui-Pei Chang 1, San-Ping Ho 2*, Chao-Shi Chen 3,Tsung-Ming Wu 4,Chin-Feng Chen 5 and Cheng-Wei Wu 6 1 Department

More information

Minimization of Mass Flow in District Heating Network Equipped with One Stage Domestic Hot Water Production Substations

Minimization of Mass Flow in District Heating Network Equipped with One Stage Domestic Hot Water Production Substations Minimization of Mass Flow in District Heating Network Equipped with One Stage Domestic Hot Water Production Substations ŻARSKI K. University of Technology and Life Sciences, Bydgoszcz *Corresponding author,

More information

Emergency Ventilation System Design - Preliminary Report Shishir Gupta

Emergency Ventilation System Design - Preliminary Report Shishir Gupta Emergency Ventilation System Design - Preliminary Report Shishir Gupta (shishir@mechartes.com), Abstract The existing stations and tunnels of Metro Railway, Kolkata are not equipped with effective emergency

More information

Air Conditioning for Industrial and Commercial Buildings

Air Conditioning for Industrial and Commercial Buildings Unit 41: Air Conditioning for Industrial and Commercial Buildings Unit code: H/601/1330 QCF level: 4 Credit value: 15 Aim This unit provides learners with an opportunity to develop the skills needed to

More information

Measurement and modelling of a multifunctional solar plus heatpump system from Nilan. Experiences from one year of test operation.

Measurement and modelling of a multifunctional solar plus heatpump system from Nilan. Experiences from one year of test operation. Measurement and modelling of a multifunctional solar plus heatpump system from Nilan. Experiences from one year of test operation. Bengt Perers 1, Elsa Andersen 2, Simon Furbo 2, Ziqian Chen 2 and Agisilaos

More information

Fire propagation over combustible exterior facades exposed to intensified flame in Japan

Fire propagation over combustible exterior facades exposed to intensified flame in Japan MATEC Web of Conferences 46, 02002 (2016) DOI: 10.1051/matecconf/20164602002 C Owned by the authors, published by EDP Sciences, 2016 Fire propagation over combustible exterior facades exposed to intensified

More information

Simulation of Full-scale Smoke Control in Atrium

Simulation of Full-scale Smoke Control in Atrium Available online at www.sciencedirect.com Procedia Engineering 11 (2011) 608 613 The 5 th Conference on Performance-based Fire and Fire Protection Engineering Simulation of Full-scale Smoke Control in

More information

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling Enhancement using Herringbone wavy & Smooth Wavy fin Exchanger for Hydraulic Oil Cooling 1 Mr. Ketan C. Prasadi, 2 Prof. A.M. Patil 1 M.E. Student, P.V.P.I.T.,Budhagaon,Sangli AP-India 2 Associate Professor,

More information

13-15, 2001 USING LIGHTING SIMULATION TO ASSESS THE PERFORMANCE OF AND INDIRECT OFFICE LIGHTING SYSTEMS IN DYNAMIC WORKPLACES

13-15, 2001 USING LIGHTING SIMULATION TO ASSESS THE PERFORMANCE OF AND INDIRECT OFFICE LIGHTING SYSTEMS IN DYNAMIC WORKPLACES Seventh International IBPSA Conference Rio de Janeiro, Brazil August 13-15, 2001 USING LIGHTING SIMULATION TO ASSESS THE PERFORMANCE OF AND INDIRECT OFFICE LIGHTING SYSTEMS IN DYNAMIC WORKPLACES R. Ries,

More information

Survey on Cooling Costs and Related Factors for Apartments in an Urban. Area of Osaka

Survey on Cooling Costs and Related Factors for Apartments in an Urban. Area of Osaka Survey on Cooling Costs and Related Factors for Apartments in an Urban Area of Osaka Noriko Umemiya Xiaoyong Lin Ginjirou Inoue Associate Professor Graduate student Graduate student Osaka City University

More information

1.1. SCOPE OF THE WORK:

1.1. SCOPE OF THE WORK: Chapter 1: Introduction 1 1. INTRODUCTION 1.1. SCOPE OF THE WORK: Multi-stage refrigeration systems are an area of growing industrial importance in large plants. These systems are known to be large power

More information

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger "COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger" 1 Prof.Gaffar G.Momin, 2 Sagar B. Tupe, 2 Swapnil A. Parate 2 Omkar G. Yewale 2 Aakash P.

More information

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE Pushpendra Singh 1, Vipin Shrivastava 2 1,2 Mechanical Engineering Department, Lakshmi Narain College of Technology (India) ABSTRACT

More information