Innovative, Compact Design

Size: px
Start display at page:

Download "Innovative, Compact Design"

Transcription

1 Innovative, Compact Design Easy, Effective Compliance

2 What in the world is? The Thermaco, Inc. Trapzilla Supercapacity Grease Trap collects free-floating (non-emulsifed) grease & oils contained in kitchen drain water flows. As most food service facility managers already know, grease buildup inside a building s grease containment system is a major cause of problems due to exterior drain line blockages. These problems jeopardize normal operations as well as create health and safety hazards within the facility itself. The proper installation of a Trapzilla Supercapacity Grease Trap can reduce or eliminate these grease problems. Use of a Trapzilla system assures minimization and/or elimination of costly sewer surcharges and fines through efficient separation and retention of free-floating grease & oils. Why does Trapzilla offer a better solution? The unique design of the Trapzilla provides advantages that a traditional, in-ground grease trap doesn t have. The Trapzilla offers patented flat separation curve technology. Traditional grease interceptors frequently suffer separation efficiency losses when the grease layer exceeds 25% of the internal liquid depth volume. This is why these older grease interceptors have very large footprints - to provide an adequate operating service period before reaching 25% full. The unique design of the Trapzilla maintains peak separation efficiency well past the 25% full threshold, allowing it to store large quantities of grease in a small footprint. 2 Thermaco, Inc Copyright 2011 Thermaco, Inc

3 The offers patented flat separation curve technology What is thermal inversion? The Trapzilla also has a horizontal baffle that prevents thermal inversion. What is thermal inversion? When warmer effluent enters the grease trap, the trapped cold water layer under the retained grease layer suddenly falls downward as rapidly rising hotter water rises to take the place of the cold water. As the cold water layer falls, it also pulls the underside of the overhead grease layer down along with it into the rapidly moving water flow along the bottom of the separator. Thermal inversion is why traditional grease separators have large internal volumes. As the grease layer approaches 25% of the internal volume depth in traditional grease traps, thermal inversion effect losses may occur. In layman s terms, the traditional grease trap becomes a gigantic lava lamp. The Trapzilla s patented/patent pending thermal inversion control design retains high-separation efficiency and high grease capacity within a small footprint ideal for space constrained food service establishments. Other Advantages? The compact design of the Trapzilla allows for installation into most facilities. Options are available enabling a Trapzilla unit to be installed on the floor, suspended from the ceiling or in-ground outside the facility. Trapzilla units are designed to treat high flows of kitchen drain water with large grease storage capacity within a small footprint unit. These units are lightweight and compact, which means that they can be maneuvered into position with minimum labor. Plumbing the unit is also a simple matter. The Trapzilla Model TZ-160 handles a 35 GPM flow and stores 160+ lbs. of grease, the Model TZ-400 handles a 75 GPM kitchen flow and stores 400+ lbs. of grease while the Model TZ-600 handles a 150 GPM kitchen flow and stores 600+ lbs. of grease. TZ-400 Efficiency ASME A Thermaco, Inc Copyright 2011 Thermaco, Inc. 3

4 Cutaway Drawing of TZ showing operating principles Removable Cover Access Plugs allow Solids and Grease extraction Optional Collar(s) allow depth adjustment to drainage piping Vent Connection Grease rises to top of inner storage tank Inlet Outlet Drain water from source enters through Inlet Baffle Solids extraction tube Clean water exits through Outlet Baffle Anchor Ring for In-Ground Installation (bury in concrete) Solids fall to bottom of tank Greasy effluent from the kitchen laminarly flows around the vertical baffle and becomes trapped in the grease storage area. The cleaned effluent flows through the outlet. The trapped grease remains segregated from the flows by means of the horizontal baffle, thus maintaining a flat separation curve. Pumping the Trapzilla is easy - the pumper unscrews the Grease and Solids plugs and vacuums out the grease and solids. 4 Thermaco, Inc Copyright 2011 Thermaco, Inc

5 can be used in a variety of configurations Light weight and compact design enables Trapzilla to be installed in places where standard grease traps would not fit or could not be accommodated. Trapzilla Options allow a variety of space saving, code friendly, creative installations. A TZ-400 with an SSOP-400/600 Support Stand installed in a basement. SSOP-400/600 Support Stand Used to support the Trapzilla Unit when installed directly on the floor of a basement or mechanical room. A TZ-600 buried in concrete outside. ECA-400/600 Extension Collar Used with in-ground and in-floor installations. Aids in lining up facility drainage piping when located deep in the ground. Trim markings at 1 intervals to make field height adjustment easy. A TZ-600 with an HA-400/600 Hanger Assembly and a PACP-400/600 Cover Plate installed between floors. HA-400/600 Hanger Assembly Used to support the Trapzilla Unit when installed between floors. PACP-400/600 Cover Plate Provides a non-slip cover when the Trapzilla unit is installed directly in the floor or locations where the cover may be in foot-traffic areas. Fabricated of durable aluminum with a diamond plate surface. MFSH-44 Flow Splitter Used when plumbing twin Trapzilla Units in parallel. Splits and diverts kitchen flow into two separate, equal flows when two (2) Trapzilla Units are necessary. Four (4) Trapzilla Units can be plumbed using three (3) flow splitters. Thermaco, Inc Copyright 2011 Thermaco, Inc. 5

6 Trapzilla can be hung in the interstitial space of the building. 6 Thermaco, Inc Copyright 2011 Thermaco, Inc

7 Trapzilla may also be installed below ground with field modifiable extension collars. Trapzilla can be installed on the floor in a basement or mechanical room. Optional Configurations can provide greater flexibility of installation. Thermaco, Inc Copyright 2011 Thermaco, Inc. 7

8 TZ-160 Specifications TZ GPM (2.21 l/s) Construction: Rotationally Molded Polyethylene Grease Retention Capacity: 160+ lbs. (72+ Kg) 3 Inlet/Outlet (75 mm) FEATURES Constructed of corrosion-resistant, linear low-density polyethylene suitable for installation in virtually any location Supercapacity Compact footprint High Separation Efficiency 18 CLEARANCE FROM TOP OF TANK REQUIRED FOR LID REMOVAL 2 VENT Conforms to ASME Standard ASME A In order to provide the best products possible, specifications are subject to change US & International Patents/Patents Pending 8 Thermaco, Inc Copyright 2011 Thermaco, Inc

9 4.5" TZ-400 Specifications 37" GREASE U.S. and International Patents Issued and Pending SOLIDS DO NOT USE MECHANICAL CRUST BREAKING DEVICES GREASE TZ GPM (4.73 l/s) Construction: Rotationally Molded Polyethylene Grease Retention Capacity: 400+ lbs. (181+ Kg) 4 Inlet/Outlet (100 mm) FEATURES Constructed of corrosion-resistant, linear low-density polyethylene suitable for installation in virtually any location Supercapacity Compact footprint High Separation Efficiency TOP VIEW AA 4.5" 36" 18.5 CLEARANCE FROM TOP OF TANK REQUIRED FOR LID REMOVAL 2 VENT OUTLET INLET 38.5" 4" PIPE INLET/OUTLET 28.5" 29" SIDE VIEW " END VIEW 31" Conforms to ASME Standard ASME A In order to provide the best products possible, specifications are subject to change US & International Patents/Patents Pending Thermaco, Inc Copyright 2011 Thermaco, Inc. 9

10 4.5" TZ-600 Specifications U.S. and International Patents Issued and Pending TZ GPM (9.46 l/s) ASME A (Tested) Flow Rating: 75 GPM Manufacturer Rated Inlet Flow Rating: 150 GPM Construction: Rotationally Molded Polyethylene Grease Retention Capacity: 600+ lbs. (272+ Kg) 4 Inlet/Outlet (100 mm) 37" TOP VIEW GREASE SOLIDS DO NOT USE MECHANICAL CRUST BREAKING DEVICES AA GREASE FEATURES Constructed of corrosion-resistant, linear low-density polyethylene suitable for installation in virtually any location Supercapacity Compact footprint High Separation Efficiency 4.5" 36" 29 CLEARANCE FROM TOP OF TANK REQUIRED FOR LID REMOVAL 2" VENT OUTLET INLET 4" PIPE INLET/OUTLET 49.5" 36.5" 37" SIDE VIEW " END VIEW 31" Conforms to ASME Standard ASME A In order to provide the best products possible, specifications are subject to change US & International Patents/Patents Pending 10 Thermaco, Inc Copyright 2011 Thermaco, Inc

11 Companion products to Solids Interceptor To help reduce the amount of incidental food solids collected in the Trapzilla Grease Interceptor, Thermaco, Inc. offers several options. Point Source Incidental Solids Separation The Flat Strainer (FS) separates and collects incidental solids such as rice, coleslaw and other food scraps larger than (3.175 mm) in diameter found in point source drain flows. Designed to replace food disposals. Dewatered solids may be emptied into a trash container. FS-1 Flat Strainer Centralized Incidental Solids Separation The Trapzilla Solids Separator (TSS) separates and collects all sizes of incidental solids. Designed to collect incidental solids in a central location, the TSS is installed upstream of the Trapzilla Grease Interceptor. Two convenient sizes are available: the TSS-70 stores 70 gal. (265 L) of solids while the TSS-95 stores 95 gal. (360 L) of solids. TSS-95 Solids Separator Thermaco, Inc Copyright 2011 Thermaco, Inc. 11

12 Cutaway Drawing of TSS - 95 showing operating principles Access Plugs allow Solids extraction Removable Cover Optional Collar(s) allow depth adjustment to drainage piping Vent Connection Inlet Outlet Drain water from source enters through Inlet Baffle Solids forced downward through Horizontal Baffle Clean water exits through Outlet Baffle Solids extraction tube Solids fall to bottom of tank Anchor Ring for In-Ground Installation (bury in concrete) Solids-laden effluent from the kitchen flow is slowed and forced downward in a horizontal baffle, where solids filter out of the flow and sink to the solids storage area. The cleaned effluent flows through the outlet. Pumping the Trapzilla Solids Separator is easy - the pumper unscrews the Solids plugs and vacuums out the solids. 12 Thermaco, Inc Copyright 2011 Thermaco, Inc

13 4.5" TSS-70 Specifications 37" U.S. and International Patents Issued and Pending SOLIDS DO NOT USE MECHANICAL CRUST BREAKING DEVICES AA TSS GPM (4.73 l/s) Manufacturer Rated Inlet Flow Rating: 75 GPM Construction: Rotationally Molded Polyethylene Solids Retention Capacity: 70 US Gallons ( Liters) 4 Inlet/Outlet (100 mm) FEATURES: Constructed of corrosion resistant materials suitable for installation in virtually any location. Compact footprint. TOP VIEW 4.5" 36" 18.5 CLEARANCE FROM TOP OF TANK REQUIRED FOR LID REMOVAL 2 VENT OUTLET INLET 38.5" 4" PIPE INLET/OUTLET 28.5" 29" SIDE VIEW " END VIEW 31" In order to provide the best products possible, specifications are subject to change US & International Patents/Patents Pending Thermaco, Inc Copyright 2011 Thermaco, Inc. 13

14 4.5" TSS-95 Specifications 37" U.S. and International Patents Issued and Pending SOLIDS DO NOT USE MECHANICAL CRUST BREAKING DEVICES AA TSS GPM (9.46 l/s) Manufacturer Rated Inlet Flow Rating: 150 GPM Construction: Rotationally Molded Polyethylene Solids Retention Capacity: 95 US Gallons ( Liters) 4 Inlet/Outlet (100 mm) FEATURES: Constructed of corrosion resistant materials suitable for installation in virtually any location. Compact footprint. TOP VIEW 4.5" 36" 29 CLEARANCE FROM TOP OF TANK REQUIRED FOR LID REMOVAL 2" VENT OUTLET INLET 4" PIPE INLET/OUTLET 49.5" 36.5" 37" SIDE VIEW END VIEW " 31" In order to provide the best products possible, specifications are subject to change US & International Patents/Patents Pending 14 Thermaco, Inc Copyright 2011 Thermaco, Inc

15 Grease Recovery Units Isolation & Containment Simply put, Isolation & Containment is protection of both the exterior plumbing (the collection system) and protection of the internal facility plumbing. Sewer codes often do not take into account the damage grease & oils can do to internal piping. Isolation (point-source grease separators) and Containment (in-ground/external grease separators) provides long-term facility plumbing system and sewer system protection. Using an interior point-source system in conjunction with a Trapzilla unit installed downstream protects the sewer system and the facility s plumbing. The typical grease generators inside a kitchen such as a three-compartment sink or pre-rinse station are treated using the grease recovery unit (GRU), while non-grease generating fixtures such as a dishwasher or mop sink are plumbed directly to the Trapzilla unit. The discharge from the GRU may also be plumbed to the Trapzilla unit. In short, Isolation is grease pretreatment at the source (GRU), while Containment is preventing grease from getting into the sewer lines (Trapzilla). Big Dipper Automatic Grease Recovery Unit Thermaco, Inc Copyright 2011 Thermaco, Inc. 15

16 What Size Trapzilla Do I Need? Suggested Models Grease Production Examples TZ-160 Low Level Grease Sandwich Shops, Coffee Production Shops TZ-400 or TZ-600 Combination of Trapzilla Grease Trap(s) and Trapzilla Solids Separator(s) Low to Moderate Level Grease Production Moderate to High Level Grease Production Pizza Parlors, Ice Cream Parlors, Bar & Grilles, Small Downtown Restaurants Full Service Restaurants Supercapacity Grease Traps Innovative, Compact Design Easy, Effective Compliance Trapzilla is a Registered Trademark of Thermaco, Inc. Trapzilla products are covered by U.S. and International patents and patents pending 6,849,176 6,878,270 7,153,439 7,186,346 * Please consult Thermaco, Inc. for details on the specific models tested, certified, accepted and/or listed by these organizations & for proper installation procedures. * TZCB-2 Copyright 2011 Thermaco, Inc Thermaco, Inc. P.O. Box 2548 Asheboro, NC info@thermaco.com (336) Fax: (336) Toll Free: (800)

Who Needs BIG DIPPER?

Who Needs BIG DIPPER? Who Needs BIG DIPPER? Here s how An affordable Big Dipper system solves tough free-floating drainwater problems by removing and recovering up to 98.6% of the grease, oils, fats 1 2 and incidental food

More information

HOW THE RIGHT GREASE INTERCEPTOR CAN HELP YOU SAVE SPACE IN A COMMERCIAL KITCHEN

HOW THE RIGHT GREASE INTERCEPTOR CAN HELP YOU SAVE SPACE IN A COMMERCIAL KITCHEN HOW THE RIGHT GREASE INTERCEPTOR CAN HELP YOU SAVE SPACE IN A COMMERCIAL KITCHEN INTRODUCTION: THE UNCONVENTIONAL KITCHEN Many engineers and architects are all too familiar with this scenario: You ve been

More information

2006 Thermaco, Inc. All rights reserved Patented/Patents Pending Specifications subject to change without notice

2006 Thermaco, Inc. All rights reserved Patented/Patents Pending Specifications subject to change without notice One to Three Compartment Sink When planning a multiple fixture discharge into a single Big Dipper, establish the size unit required by following the method outlined in the sizing section of this manual.

More information

How To Size A Big Dipper Unit

How To Size A Big Dipper Unit Sizing Big Dipper Systems In Food Service Operations How To Size A Big Dipper Unit The purpose of this sizing procedure is to give a specifying engineer a simple method for determining the proper size

More information

W-150-IS Specifications

W-150-IS Specifications W-150-IS Specifications MOTOR/TIMER ENCLOSURE 14 CLEARANCE FROM TOP OF TANK REQUIRED FOR STRAINER BASKET & LID REMOVAL 10.25 2 PIPE / EMPTY INTO COOKING OIL RECYCLING CONTAINER DAILY GC-7 GREASE 8 QUART

More information

W-750-IS Specifications

W-750-IS Specifications Big Dipper IS Central Automatic W-750-IS Specifications MOTOR/TIMER ENCLOSURE 1 CLEARANCE FROM TOP OF TANK REQUIRED FOR STRAINER BASKET & LID REMOVAL 23.375 EMPTY INTO COOKING OIL RECYCLING CONTAINER DAILY

More information

OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS

OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES INTERCEPTORS OPERATION, INSTALLATION AND MAINTENANCE INSTRUCTIONS 5400-5500 SERIES INTERCEPTORS 5401 75 4NH 5500 50 3IPS INSTALLATION Place the Wade interceptor downstream of the drain which will supply the oil laden

More information

Grease Interceptors and Oil Separators

Grease Interceptors and Oil Separators Grease Interceptors and Oil Separators 1) All food service establishments and vehicle maintenance facilities shall have devices installed for separating and retaining grease and oils known as grease interceptors

More information

Engineering Fact Sheet

Engineering Fact Sheet GREASE INTERCEPTORS Service Alert Sensors Cast Iron Access Hatchway General Information Sewers back up an estimated 400,000 times each year in the United States causing approximately 40,000 municipal sanitary

More information

Product Overview. About Us. Grease Traps Generic Types. Extended Capacity Hydromechanical Grease Traps

Product Overview. About Us. Grease Traps Generic Types. Extended Capacity Hydromechanical Grease Traps About Us Product Overview Extended Capacity Hydromechanical Grease Traps Endura XL 75 Models DGT75 598L Light Trafficable Lid DGT75P 598L Pedestrian Lid Industry leading separation efficiency based on

More information

There are a few factors critical in the operation of a grease interceptor, which are: Design, Sizing, Proper installation and maintenance.

There are a few factors critical in the operation of a grease interceptor, which are: Design, Sizing, Proper installation and maintenance. TEL: 773-341-3030 FAX: 773-341-3046 TOLL FREE: 1-800-465-2736 WEBSITE: www.mifab.com Grease Interceptors Description of Operation: There are a few factors critical in the operation of a grease interceptor,

More information

Read Only Document Not For Distribution

Read Only Document Not For Distribution Chapter 5 Traps, Cleanouts and Backwater Valves 5.1 SEPARATE TRAPS FOR EACH FIXTURE a. Plumbing fixtures shall be separately trapped by a water seal trap placed as close as possible to the fixture outlet.

More information

CHAPTER 10 TRAPS AND INTERCEPTORS

CHAPTER 10 TRAPS AND INTERCEPTORS CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

4. TECHNOLOGY AND DESIGN CRITERIA

4. TECHNOLOGY AND DESIGN CRITERIA 4. TECHNOLOGY AND DESIGN CRITERIA 12 Current FOG pretreatment technology typically takes the form of smaller, metal, grease-handling devices found in the kitchen area of the facility; or large, in-ground,

More information

TOWNSHIP OF WEST WINDSOR P.O. BOX 38; 271 CLARKSVILLE ROAD WEST WINDSOR, NJ (609) FAX (609)

TOWNSHIP OF WEST WINDSOR P.O. BOX 38; 271 CLARKSVILLE ROAD WEST WINDSOR, NJ (609) FAX (609) TOWNSHIP OF WEST WINDSOR P.O. BOX 38; 271 CLARKSVILLE ROAD WEST WINDSOR, NJ 08550 (609) 936-8400 FAX (609) 799-2136 OPERATIONAL GREASE CONTROL PLAN APPLICATION EXISTING ESTABLISHMENTS Directions: Complete

More information

Installation & Operation Instructions For Big Dipper Series Internal Strainer (IS) Units

Installation & Operation Instructions For Big Dipper Series Internal Strainer (IS) Units Installation & Operation Instructions For Big Dipper 40000 Series Internal Strainer (IS) Units Models W-750-IS and W-1250-IS (Including 230 VAC Units) Big Dipper W-750-IS Installed in a Basement ADA Copyright

More information

I. Best Management Practices (BMPs) to Prevent Blockages in the Sanitary Sewer System

I. Best Management Practices (BMPs) to Prevent Blockages in the Sanitary Sewer System BMP Train kitchen staff and other employees about how they can help ensure BMPs are implemented. Post "No Grease" signs above sinks and on the front of dishwashers. I. Best Management Practices (BMPs)

More information

Design of Precast Concrete Grease Interceptors

Design of Precast Concrete Grease Interceptors Design of Precast Concrete Grease Interceptors Claude Goguen, PE National Precast Concrete Association 2015 Onsite Wastewater Mega Conference Terminology Terminology Terminology Grease is the Word If you

More information

Installation & Operation Instructions For Big Dipper Series Automatic Solids Transfer (AST) Units

Installation & Operation Instructions For Big Dipper Series Automatic Solids Transfer (AST) Units Installation & Operation Instructions For Big Dipper 40000 Series Automatic Solids Transfer (AST) Units Models W-250-AST, W-750-AST and W-1250-AST (Including 230 VAC Units) A Big Dipper W-750-AST in a

More information

Grease Interceptors. General For the purpose of this standard, the following terms shall have the meaning indicated in this section.

Grease Interceptors. General For the purpose of this standard, the following terms shall have the meaning indicated in this section. Building Division 4800 W. 92 nd Avenue Westminster, Colorado 80031 303-658-2075 permits@cityofwestminster.us Grease Interceptors Where Required Every food serving, food preparing, food catering, or meat

More information

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2 CHAPTER 10 TRAPS AND INTERCEPTORS < 1001.0 Traps Required. Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.1, shall be separately trapped by an approved type

More information

Program Introduction and Policy 1. Frequently Asked Questions 2. Device Maintenance..3. Best Management Practices...4

Program Introduction and Policy 1. Frequently Asked Questions 2. Device Maintenance..3. Best Management Practices...4 Carmel Utilities, in accordance with the National Pretreatment Program set forth by E.P.A. regulations (40 CFR 403), has hereby enacted a program for the controlling of Fats, Oils, and Grease discharges

More information

Fat, Oil, and Grease (FOG) Program Frequently Asked Questions (FAQ)

Fat, Oil, and Grease (FOG) Program Frequently Asked Questions (FAQ) Fat, Oil, and Grease (FOG) Program Frequently Asked Questions (FAQ) Q. Who is San Jacinto River Authority (SJRA)? A. San Jacinto River Authority (SJRA) is one of 10 major river authorities in Texas created

More information

APPENDIX F: GREASE SEPARATION DEVICE SIZING OPTIONS

APPENDIX F: GREASE SEPARATION DEVICE SIZING OPTIONS APPENDIX F: GREASE SEPARATION DEVICE SIZING OPTIONS 55 Method 1. Evaluation Based upon 20-25 Minute Hydraulic Retention Grease Separation Device Sizing Table Maximum, worst-case hydraulic loading conditions

More information

INSPECTION OF COMMERCIAL KITCHEN PLUMBING

INSPECTION OF COMMERCIAL KITCHEN PLUMBING INSPECTION OF COMMERCIAL KITCHEN PLUMBING 801.1 SCOPE Food-handling establishments 2 - by John Williams, Jr. Plumbing Control Supervisor Onondaga County Water Environment Protection Commercial Kitchens

More information

GREASE SEPARATION DEVICE SIZING OPTIONS

GREASE SEPARATION DEVICE SIZING OPTIONS GREASE SEPARATION DEVICE SIZING OPTIONS Method 1. Evaluation Based upon 20-25 Minute Hydraulic Retention Grease Separation Device Sizing Table Maximum, worst-case hydraulic loading conditions typified

More information

PLEASE DO NOT DISCARD THE ATTACHED DOCUMENT IS NECESSARY FOR THE INSTALLATION OF YOUR GREASE TRAP.

PLEASE DO NOT DISCARD THE ATTACHED DOCUMENT IS NECESSARY FOR THE INSTALLATION OF YOUR GREASE TRAP. PLEASE DO NOT DISCARD THE ATTACHED DOCUMENT IS NECESSARY FOR THE INSTALLATION OF YOUR GREASE TRAP. GI SERIES GREASE TRAP INSTALLATION GUIDE Overview Atlantic Metalworks GI series grease traps are designed

More information

c. Direct or indirect?

c. Direct or indirect? ~ \ 1.) GENERAL a. Definitions: Chapter B Code References (1) Air-break Comm 81.01 (5) (2) Air-gap, drain system Comm 81.01 (6) (3) Flood level rim Comm 81.01(102) (4) sink Comm 81.01(105) (5) Indirect

More information

Web:

Web: P.O Box - 95466, United Arab Emirates Tel: +971 4 2637073, Mobile: +971 55 2191246, +971 52 864 1667 Email: info@sancouae.com, Web: It's about Peace of mind and a job done right, First time, Every time

More information

Combined FOG intercept and treatment system

Combined FOG intercept and treatment system BIOLOGICAL DRAIN MAINTENANCE SYSTEM Combined FOG intercept and treatment system designed to retain and breakdown Fats, Oils and Grease (FOG) to prevent them from entering the drainage system. The system

More information

ECOJET GREASE LEVEL SENSOR

ECOJET GREASE LEVEL SENSOR ACO Passavant Installation guide ECOJET GREASE LEVEL SENSOR AUTHOR Kate Jennings DATE COMPLETED 8 August 2016 DATE COMPLETED V13 ACO Polycrete, 134-140 Old Bathurst Road, Emu Plains, NSW 2750 Tel: +61

More information

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw SEMI-INSTANTANEOUS ENERGY: STEAM TO WATER U-TUBE SINGLE-WALL & DOUBLE-WALL HEAT EXCHANGERS FLOOR DRAIN Typical Construction Figure 34-1 FLOOR DRAIN 1. U-tube

More information

Food Establishment Guidelines. Food Service Plan Review

Food Establishment Guidelines. Food Service Plan Review Food Service Plan Review Food service plan review in the City of Grand Prairie begins at the Environmental Services Department at the Development Center, 201 NW 2 nd Street in Suite 100. The City of Grand

More information

Commercial Hot Water Maker

Commercial Hot Water Maker Boiler Mate Series Commercial Hot Water Maker Indirect-Fired Water Heaters Models WH-7C and WH-10C 1 INNOVATIVE DESIGN FOR REAL WORLD APPLICATIONS The Boiler Mate Series commercial Hot Water Maker design

More information

Installation & Maintenance Instructions For Trapzilla Grease Interceptors

Installation & Maintenance Instructions For Trapzilla Grease Interceptors THERMO Technology Installation & Maintenance Instructions For Trapzilla Grease Interceptors * onforms to SME Standard SME..-000 Please consult Thermaco, Inc. for specific models tested, certified and/or

More information

Food Service Plan Review Information

Food Service Plan Review Information Food Service Plan Review Information New or remodeled food preparation facilities, and those changing ownership, must undergo a plan review process prior to a health permit being issued. The purpose of

More information

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

TOWNSHIP OF WEST WINDSOR 271 CLARKSVILLE ROAD, P.O. BOX 38 WEST WINDSOR, NJ (609) FAX (609)

TOWNSHIP OF WEST WINDSOR 271 CLARKSVILLE ROAD, P.O. BOX 38 WEST WINDSOR, NJ (609) FAX (609) TOWNSHIP OF WEST WINDSOR 271 CLARKSVILLE ROAD, P.O. BOX 38 WEST WINDSOR, NJ 08550 (609) 936-8400 FAX (609) 799-2136 RETAIL FOOD ESTABLISHMENT GREASE CONTROL PLAN APPLICATION Directions - Completed Forms

More information

Keeping. Fats, Oils, and. Grease. Out of the Sewer

Keeping. Fats, Oils, and. Grease. Out of the Sewer Keeping Fats, Oils, and Grease Out of the Sewer Questions and Answers for Food Service Establishments regarding Fats, Oil, and Grease and Grease Removal Devices City of Paso Robles, Wastewater Division,

More information

EV-PRO CONDENSATE SEPARATORS

EV-PRO CONDENSATE SEPARATORS EV-PRO CONDENSATE SEPARATORS SUSTAINABLE CONDENSATE MANAGEMENT The EV-Pro line of condensate separators use specially treated, adsorbent, polypropylene media, the FS-CURTIS EV-PRO Condensate Separators

More information

CHAPTER 8 APPURTENANCES

CHAPTER 8 APPURTENANCES CHAPTER 8 APPURTENANCES 8.1 Introduction This chapter discusses several types of equipment used in onsite wastewater treatmenl 'disposal systems-that have 'general application to the components prev ously

More information

1 Exam Prep Plumber s Handbook Tabs and Highlights

1 Exam Prep Plumber s Handbook Tabs and Highlights 1 Exam Prep Plumber s Handbook Tabs and Highlights These 1 Exam Prep Tabs are based on the Plumber s Handbook Revised 2006. Each Tabs sheet has five rows of tabs. Start with the first tab at the first

More information

InterSeptor Centrifugal Separators Operating & Maintenance Manual

InterSeptor Centrifugal Separators Operating & Maintenance Manual General Information: This manual was prepared to assist in the installation, operation, and maintenance of PEP ICS centrifugal separator systems. For immediate response to questions not covered in this

More information

Commercial food preparation and service

Commercial food preparation and service Commercial food preparation and service Released: 1 July 2017 Used waters from business activities such as food preparation and dish washing contain oil/grease and suspended solids at concentrations or

More information

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

ICP Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. ICP Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A 1 inch diameter faucet, where the inside edge of the spout opening is 2.5 inches away

More information

Modular Grease Trap MGTA

Modular Grease Trap MGTA Modular Grease Trap MGTA and MGTA) Installation Requirements Installation Water Requirements Corporation Water Corporation 22 Ethel Ave Brookvale NSW 2100 Postal: PO Box 255 Collaroy NSW 2097 Freecall

More information

Grease Control Device Maintenance Recordkeeping

Grease Control Device Maintenance Recordkeeping Grease Control Device Maintenance Recordkeeping All food service establishments are required to keep maintenance records for their grease traps, interceptors, and mechanical grease control devices for

More information

BUILDING AND CODES DEPARTMENT 350 Pageant Lane Suite 309 Clarksville, TN 37040

BUILDING AND CODES DEPARTMENT 350 Pageant Lane Suite 309 Clarksville, TN 37040 Phone 931-648-5718 BUILDING AND CODES DEPARTMENT 350 Pageant Lane Suite 309 Clarksville, TN 37040 Fax 931-553-5121 Food Service Establishment Fats, Oil and Grease Best Management Practices 1. Introduction

More information

A Versatile Plumbing And Waste Solution That Saves Time and Money

A Versatile Plumbing And Waste Solution That Saves Time and Money VACUUM PLUMBING SYSTEMS A Versatile Plumbing And Waste Solution That Saves Time and Money Vacuum Plumbing Systems move waste up and out A Vacuum Plumbing System eliminates the need for floor sinks for

More information

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)*

CHaPTeR 10. TRaPS and INTeRCePTORS. Table 10-1 Horizontal lengths of Trap arms (except for water closets and similar fixtures)* CHaPTeR 10 TRaPS and INTeRCePTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

Prohibitions on using

Prohibitions on using Prohibitions on using Chemicals, Enzymes, or Bacteria in Grease Traps and Interceptors CHEMICALS ENZYMES BACTERIA Chemicals: the use of chemicals to clean grease traps or interceptors is strictly prohibited

More information

Structural Guidelines. Food Service Establishments. Retail Food Stores

Structural Guidelines. Food Service Establishments. Retail Food Stores Structural Guidelines for Food Service Establishments and Retail Food Stores Jefferson County Department of Health Food & Lodging Protection Division 1 Before construction or remodeling of a food service

More information

MINIMUM CONSTRUCTION STANDARDS AND SPECIFICATIONS CHECKLIST

MINIMUM CONSTRUCTION STANDARDS AND SPECIFICATIONS CHECKLIST Rev: 10/23/08 MINIMUM CONSTRUCTION STANDARDS AND SPECIFICATIONS CHECKLIST The following standards apply to constructing, renovating or converting buildings to use for preparing, processing, storing or

More information

ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES

ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES ADDITIONAL INFORMATION FOR RETAIL FOOD PREMISES INTRODUCTION Wastes like cooking oil, grease and food solids are produced by food outlets and services throughout the Timaru District every day. When this

More information

CHAPTER 9 VENTS SECTION

CHAPTER 9 VENTS SECTION CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing

More information

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer.

IPC Plumbing Exam. Name: Carefully read each question and then circle the letter of the best answer. IPC Plumbing Exam Name: Date: Score: Carefully read each question and then circle the letter of the best answer. 1. A vent stack handling 25 dfu s with a developed length of 35 feet shall be inches minimum

More information

Installation & Maintenance Instructions For Trapzilla Grease Interceptors

Installation & Maintenance Instructions For Trapzilla Grease Interceptors THERMO Technology Installation & Maintenance Instructions For s onforms to SME Standard SME..-000 Please consult Thermaco, Inc. for specific models tested, certified and/or listed by these organizations.

More information

168 Spotnap Road Charlottesville, VA Tel (434) Fax (434)

168 Spotnap Road Charlottesville, VA Tel (434) Fax (434) Re: Fats, Oils and Grease (FOG) Abatement Program Dear Restaurant/Food Service Facility Manager: The Albemarle County Service Authority (ACSA) prides itself on maintaining the general public health of

More information

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard) Choosing Location of the water heater This water heater is of the direct vent design. It takes all of its fresh air for combustion from outside the building which it is installed. It also vents the combustion

More information

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010

Land Use and Environmental Service Agency (Code Enforcement) Plumbing 2010 General: 1) (Q) Who enforces the cutting and notching requirements found in the plumbing code? (A) The plumbing inspector would question the contractor initially. A building inspector would either take

More information

F.O.G. 2/8/2013. Frequently Asked Questions. Defining Fats, Oils, & Grease (FOG)

F.O.G. 2/8/2013. Frequently Asked Questions. Defining Fats, Oils, & Grease (FOG) F.O.G. Fats, Oils, and Grease by Dan Burke- National Waste Associates 1 Frequently Asked Questions What is FOG? Why is FOG an issue for my business? Is my business required to have a grease removal device?

More information

Shop Online Eccotemp.com/products. Store Locator Eccotemp.com/locator. Product Support support.eccotemp.com.

Shop Online Eccotemp.com/products. Store Locator Eccotemp.com/locator. Product Support support.eccotemp.com. L5 20 minute automatic safety shutoff timer Battery igniter - no electricity needed Minimum flow rate is approximately 0.4 gallons per minute Up to 18 hours of use on a 20 lb. tank Shower head with On/Off

More information

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X X

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter X X X Adopt Entire Chapter as amended (amended sections listed below) X X X X X X X CALIFORNIA PLUMBING CODE MATRIX ADOPTION TABLE CHAPTER 10 - TRAPS AND INTERCEPTORS (Matrix Adoption Tables are non-regulatory, intended only as an aid to the user. See Chapter 1 for state agency authority

More information

SPECIFICATION SECTION:

SPECIFICATION SECTION: SPECIFICATION SECTION: Date: STORM WATER TREATMENT STORMEXX CLEAN CATCH BASIN INSERTS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the Inserts for use at existing storm water catch basins in roadways,

More information

Level I Chapter 1 Worksheet

Level I Chapter 1 Worksheet Chapter 1 Worksheet 1. For applicability requirements of the Plumbing Code, refer to: a. Building Code b. Administration and Enforcement Code c. Plumbing Code d. Residential Code 2. The provisions of the

More information

PLAN REVIEW GUIDELINES AND SPECIFICATIONS FOR FOOD SERVICE ESTABLISHMENTS

PLAN REVIEW GUIDELINES AND SPECIFICATIONS FOR FOOD SERVICE ESTABLISHMENTS PLAN REVIEW GUIDELINES AND SPECIFICATIONS FOR FOOD SERVICE ESTABLISHMENTS COURTESY OF WHITMAN COUNTY DEPARTMENT OF PUBLIC HEALTH ENVIRONMENTAL HEALTH SECTION 310 NORTH MAIN STREET COLFAX, WA 99111 (509)

More information

RESOLUTION Adopted this day of, President of June Lake Public Utility District and its Board of Directors

RESOLUTION Adopted this day of, President of June Lake Public Utility District and its Board of Directors RESOLUTION 2017-04 RESOLUTION OF THE BOARD OF DIRECTORS OF JUNE LAKE PUBLIC UTILITY DISTRICT ESTABLISHING BEST MANAGEMENT PRACTICES FOR THE DISPOSAL OF FATS OILS AND GREASE Whereas, the June Lake Public

More information

INDIRECT FIRED WATER HEATERS

INDIRECT FIRED WATER HEATERS H E A T T R A N S F E R P R O D U C T S INDIRECT FIRED WATER HEATERS RESIDENTIAL COMMERCIAL Heat Transfer Products, Inc., reserves the right to make product changes or updates without notice. Heat Transfer

More information

STACKS AND STACK VENTS

STACKS AND STACK VENTS CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing

More information

Fats, Oils and Grease Program (FOG)

Fats, Oils and Grease Program (FOG) Fats, Oils and Grease Program (FOG) SECTION A GENERAL INFORMATION 1. Facility Name: 2. Facility Street Address: City: State: Zip: Phone Number: Fax Number: 3. Business Mailing Address: (if different from

More information

APPENDIX J ILLUSTRATIONS

APPENDIX J ILLUSTRATIONS The following figures have been included in the 1994 edition of the Standard Plumbing Code to aid in interpreting this code. The figures are not to be construed as superseding the written text, but merely

More information

Specifying High-Efficiency Water Heaters for Food Service

Specifying High-Efficiency Water Heaters for Food Service Specifying High-Efficiency Water Heaters for Food Service May 14 th, 2010 Presented by: Don Fisher Water Heater Selection and Specification Selection Efficiency Economics Myths & Limitations Tank versus

More information

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction

INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER. Compact Design. High Recovery. Energy Efficient. Stainless Alloy Construction INDIRECT FIRED, SEMI-INSTANTANEOUS STEAM & BOILER WATER HEATER Compact Design High Recovery Energy Efficient Stainless Alloy Construction Factory Packaged Integral Safety System ASME Constructed & Stamped

More information

SERVING CANADA INSTALLATION INSTRUCTIONS REVISED: AUGUST 2014

SERVING CANADA INSTALLATION INSTRUCTIONS REVISED: AUGUST 2014 SERVING CANADA INSTALLATION INSTRUCTIONS REVISED: AUGUST 2014 INDEX: UNPACKING INSTRUCTIONS page 2 INSTALLATION INSTRUCTIONS page 3 CONNECTIONS page 6 Equipment must be installed in compliance with all

More information

Used Fluid Handling Portable Used-Oil Gravity Drains

Used Fluid Handling Portable Used-Oil Gravity Drains Portable Used-Oil Gravity Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s)

More information

Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective

Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective 2012 Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective 2012 - Superior Restaurant Services 3/21/2012 2012 - Superior Restaurant Services 2 Contents Introduction...

More information

Lubrication Tools and Equipment Portable Oil Drains

Lubrication Tools and Equipment Portable Oil Drains Portable Oil Drains Choose the fluid handling equipment that fits your needs. Traditional Drain: the traditional method for handling used fluids allows gravity to drain fluids from vehicle(s) into a portable

More information

Mechanical System Description

Mechanical System Description 1. Building Description: Mechanical System Description The building is a Type-1B construction, 9-levels, non-high rise building with 67 affordable family housing units. The first level of the structure

More information

2016 Plumbing Supplemental Plan Review List

2016 Plumbing Supplemental Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Plumbing Supplemental Plan Review List POTABLE WATER SYSTEM P1. Specify which fixtures are for private use and which are for

More information

ACO Construction & Building Products

ACO Construction & Building Products ACO Construction & Building Products Light oil and sediment separator system ACO Environment Oleopator P Oil Water Separator Operating Guide 1. Installation 2. Initial set-up/commissioning 3. Operation

More information

CHAPTER 10 TRAPS AND INTERCEPTORS

CHAPTER 10 TRAPS AND INTERCEPTORS CAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved

More information

ROTISSERIE OVEN PROGRAM GUIDE

ROTISSERIE OVEN PROGRAM GUIDE ROTISSERIE OVEN PROGRAM GUIDE Goslyn, LP 1904 University Business Dr. #310 McKinney TX 75071 Phone: 888-648- 5040 Fax: 214-618- 3765 WWW.GOSLYN.COM DEC 2013 table of contents general overview 3 Installation

More information

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization

Minor Home Repairs. November 4, County of Henrico Department of Community Revitalization Minor Home Repairs 1 November 4, 2017 County of Henrico Department of Community Revitalization Educate homeowners on basic technical skills that will help the homeowner understand daily operations of different

More information

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI.

COBREX. Semi-Instantaneous. Steam-Fired Domestic Hot Water Generator. Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty. PVI. COBREX Semi-Instantaneous Steam-Fired Domestic Hot Water Generator ENGINEERED DUPLEX ALLOY Up to 7000 MBH 150/ 175/ 215 Gallon Tank 25-year Warranty PVI.com Steam-Fired Domestic Hot Water Generator COBREX

More information

Food Service Establishment Plan Review Form

Food Service Establishment Plan Review Form CITY OF PARK RIDGE 505 BUTLER PLACE PARK RIDGE, IL 60068 TEL: 847/ 318-5291 FAX: 847/ 318-6411 TDD:847/ 318-5252 URL:http://www.parkridge.us Food Service Establishment Plan Review Form THE FOLLOWING INFORMATION

More information

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS SECTION 22 34 00 (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS System shall provide a complete hot water return throughout the entire system with balancing (flow control) valves not less than 10 feet from

More information

INSTALLATION INSTRUCTIONS (CANADA)

INSTALLATION INSTRUCTIONS (CANADA) INSTALLATION INSTRUCTIONS (CANADA) MODEL GOS40 (OTHER MODELS ARE SIMILAR) INDEX: UNPACKING INSTRUCTIONS page 2 INSTALLATION INSTRUCTIONS page 3 Regular Installation Design but not limited to page 6 CONNECTIONS

More information

Operation Manual SA Vent. Models Kona, Pali and Mistral

Operation Manual SA Vent. Models Kona, Pali and Mistral Operation Manual SA Vent Models Kona, Pali and Mistral 765 Westminster Street Providence, Rhode Island 02903 U.S.A. Tel: (401) 273-3300 Fax: (401) 273-3328 www.equipex.com e-mail: service@equipex.com IMPORTANT

More information

SECTION GYPSUM PLASTER

SECTION GYPSUM PLASTER SECTION 09210 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation for support of gypsum plaster used as a finish for partitions and ceilings

More information

VENTLESS DOOR-TYPE DISHWASHER

VENTLESS DOOR-TYPE DISHWASHER Item # Quantity C.S.I. Section 11400 VENTLESS STANDARD FEATURES Internal condensing system minimizes water vapor Does not require a vent hood Energy recovery Sense-A-Temp 70 F rise electric booster heater.74

More information

ADAMS COUNTY HEALTH DEPARTMENT PLAN REVIEW APPLICATION FOR FOOD ESTABLISHMENTS This is not a Food Establishment application. Fees are non refundable

ADAMS COUNTY HEALTH DEPARTMENT PLAN REVIEW APPLICATION FOR FOOD ESTABLISHMENTS This is not a Food Establishment application. Fees are non refundable A7 ADAMS COUNTY HEALTH DEPARTMENT 108 W. MAIN, RITZVILLE, WASHINGTON 99169 - TELEPHONE (509) 659-3315 425 E. MAIN, STE. 700, OTHELLO, WASHINGTON 99344 - TELEPHONE (509) 488-2031 ADAMS COUNTY HEALTH DEPARTMENT

More information

Installation & Maintenance Instructions For Trapzilla TZ-1826

Installation & Maintenance Instructions For Trapzilla TZ-1826 THERMO Technology Installation & Maintenance Instructions For Trapzilla TZ-86 For additional information on Trapzilla or other Thermaco products, please visit www.trapzilla.com or call at -800-6-0. EF

More information

Drain and Vent Systems 6 CE Hours

Drain and Vent Systems 6 CE Hours Drain and Vent Systems 6 CE Hours Wisconsin Contractors Institute N27 W23953 Paul Road, Suite 203 Pewaukee, WI 53072 www.wicontractorsinstitute.com 262-409-4282 What is the purpose of this course? The

More information

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Design and Construction Standards SECTION PLUMBING EQUIPMENT SECTION 15450 PLUMBING EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES: A. Water heaters. B. Packaged water heating systems. C. Water storage tanks. D. Water softeners. E. Pumps. F. Circulators. 1.2 REFERENCES

More information

Silhouette. Feedwater Heater. Boiler Feedwater

Silhouette. Feedwater Heater. Boiler Feedwater Roth Roth Low Low Silhouette Silhouette TRAY DEAERATORS Boiler Boiler Feedwater Feedwater Heater Heater Capacities Capacities to to 50,000 50,000 lb/hr lb/hr Model RDTV-150-5-1-2 vertical tray type deaerator

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Product Preservers Anti-Scale System Chemical-Free, Salt-Free Scale Prevention Introduction The Product Preservers Anti-Scale System will condition the tap

More information

2015 UPC Chapter 8 Indirect Wastes RV

2015 UPC Chapter 8 Indirect Wastes RV PLEASE DO NOT BOOKMARK ANY ANYTIMECE WEBPAGES! Our system will remember the last page you viewed when logging out and back in but please DO NOT exit out when taking a test. Your place will NOT be saved.

More information

SB Series Brazed Plate Heat Exchanger Installation Manual

SB Series Brazed Plate Heat Exchanger Installation Manual SB Series Brazed Plate Heat Exchanger Installation Manual HOT COLD Exploded view of Schmidt SB Brazed Plate Heat Exchanger. WARNING Before proceeding with installation and operation read entire manual

More information

C44A/C44AW DISHWASHER

C44A/C44AW DISHWASHER Item # Quantity C.S.I. Section 11400 C44A/C44AW DISHWASHER STANDARD FEATURES 202 racks per hour C44A 126 racks per hour C44AW Opti-RinSe system Ball detent clutch conveyor drive mechanism Top mounted controls

More information

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES 2.05 PLUMBING GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.05 It is expected that the plumbing design professional will conform to accepted good engineering design practices.

More information