74 Catalogue 3.1. Wastewater lifting stations
|
|
- Sabina Hudson
- 5 years ago
- Views:
Transcription
1 7 Catalogue. Wastewater lifting stations
2 Wastewater lifting stations for wastewater containing raw sewage for free standing installation and for installation in a concrete floor Page for underground installation Page 08 for wastewater without sewage Complete range for freestanding installation and for installation in a concrete floor Page for underground installation Page Submersible pumps Page 7 for fixed or mobile use, for residential, commercial, public and industrial applications Warning and control units Page 8 Convenient monitoring and control of lifting stations and pumps Individual Solutions Page 7 Catalogue. 7
3 Wastewater lifting stations Everything the specialist needs to know Water flows upwards? It often happens that wastewater cannot be drained with gravity because the sewer is higher than the drainage point in the basement. In this case a lifting station or pump must be used. pump the wastewater via pressure pipes into the sewer. Backwater level If the sewer is higher than the drainage point in the basement, a lifting station has to be used The appropriate lifting station Particle size: The particle size of a pump specifies how many millimetres of free passage through the pump are available. According to the construction and testing regulations (EN 00) for wastewater lifting stations for wastewater without sewage (grey water), the maximum solids size (particle size) in the overall system is 0 mm, for wastewater with sewage (black water) it is 0 mm (EN 00). Different product lines are available for the two different types of wastewater For wastewater with sewage When it comes to draining toilets and urinals, sewage lifting stations must be used. The lifting stations of the Aqualift F series are available for installation in the interior or exterior of buildings. All lifting stations are also available as twin stations. For wastewater without sewage Household wastewater from washing machines, showers or bathtubs. The lifting stations Aqualift S and Minilift can be used for these drainage purposes. Pumping volume: Another important point is the pumping volume of a lifting station. EN 0 requires the pumping volume of the system to be larger than the total volume of the pressure pipe. This means that the wastewater in the pressure line is replaced during every pumping process. And if the backwater preventer is leaking this does not lead to the pump switching on and off all the time. Nonchokable or macerator pumps? The reliable function depends on selecting the appropriate lifting station and also on the technically correct installation of the lifting station. KESSEL offers two types of pumps. Nonchokable pumps and macerator pumps. Each of these pumps has special properties. Explosion protection: Accidents or spills could result in hazardous liquids entering the lifting station which could result in an explosion risk environment. If the possibility is real, an ATEX explosion protected pumping system should be used. Nonchokable pumps have a large free space inside the pump housing. As a consequence, solid and long fibrous, high consistency substances, such as sanitary towels, textiles etc., can pass through the pump housing easily. It is often necessary to expend more energy to achieve an efficient pump output. Macerator pumps are especially suitable for long fibres and where solid bodies can be comminuted, even larger sizes. This allows the wastewater to be transported reliably through small pressure pipes even over long distances (pressure drainage). 7 Catalogue.
4 Wastewater lifting stations Everything the specialist needs to know Installation options Example for installation in an exposed wastewater pipe Example for installation in a concrete slab/floor Example for underground installation Exposed installation Installation in a concrete floor Underground installation Freestanding lifting stations can be installed very easily and without a great deal of expenditure, and are suitable for singlefamily homes all the way up to larger commercial / industrial applications. Smaller systems can easily be placed in an existing basement room. Larger systems are better installed in a separate utility room. The use of basements to provide further space for accommodation is becoming increasingly important. Frequently, toilets, showers or washing facilities are located in the basement. For such applications, KESSEL supplies lifting stations for installation in concrete floors. These lifting stations simply disappear in the ground and offer another special advantage. The drain integrated in the cover can drain away all surface water. Even in the event of a pipe burst or leak, the pump discharges water continually over the backwater level. Installing lifting stations within a building often wastes valuable living space as well as potentially causing operational noise. New solutions are available giving the home owner decisive advantages. Often the correct choice is to move the lifting station outdoors freeing up living space, eliminating operation noise as well as making access for servicing companies more convenient. Depending on the requirements KESSEL offers single or twin pump systems and various chamber diameters based on the size of the pumps required. Telemetric system The KESSEL TeleControl system allows pump activity, messages or errors to be sent via a GSM interface to up to three mobile phones. This keeps the pump operator informed about the current operational status of the lifting station and allows quick reaction time if required. SMS Operator/Owner Receives a weekly message with the operational status of the lifting station. KESSEL TeleControl Modem Send message... SMS Facility manager SMS Plumber Receives all error messages and can decide if and when an onsite inspection of the system is required. Receives all pump actions, messages and errors and is always kept up to date with the status of the lifting station. Catalogue. 77
5 Wastewater lifting stations Everything the specialist needs to know General information and standards Level sensors / probes and alarm probes INFORMATION Level sensors and probes measure the level of the pumping medium in the collecting tank of a lifting station and trigger the pumping process of one or several pumps from a specified filling level onward. If the level in the collecting tank continues to rise, an acoustic warning signal can be give via an alarm probe (which also measures the level of the pumping medium). Pressure sensor The closed air volume within a pressure sensor is compressed by a rising water level in the collecting tank of a lifting station. The resulting difference in air pressure is measured by a pressure sensor in the control unit and used to regulate the starting and stopping of the lifting station pumping process. Pneumatic level measurement is a straightforward and lowcost method of level measurement, but does have disadvantages when the system is used irregularly, when wastewater is extremely greasy or when pressure hoses are very long or condensate in the pressure hose impedes measurement. Conductance probe A conductance probe uses AC voltage and measures whether there is any conductive fluid between two measuring points. If there is, current flows and the control unit triggers the pumping process. Thus a conductance probe is a simple and lowcost method of level measurement. It only works with conductive fluids, however, and cannot be used for the pumping of rainwater or condensate. Float switch Float switches are switching devices which are actuated by a float which swims on the surface of the pumping medium. If the water level rises within the collecting tank, the switching device is triggered via the change in level of the float, and the lifting station pump is activated. Float switches are a simple and proven type of level measurement. They have some weaknesses when heavily soiled wastewater is to be pumped, since material becomes deposited on the float and can interfere with level measurement. Hydrostatic sensor With this method of hydrostatic pressure measurement, the water pressure is measured using a semiconductor and the downstream electronics generate an analogue signal from this. The pumps are activated from a specified level onward. A hydrostatic sensor can be used to measure different levels. This makes it possible to measure both the alarm level and pumping level and save on a second probe. However, such hydrostatic sensors usually cost more than other level probes. Optical probe In addition to the level sensors described above, an optical probe can be used as an alarm probe. If the sensor surface becomes wet, the refraction angle of an infrared signal changes, signalling that the alarm level has been reached. The optical probe is ideal as an alarm probe since it works reliably even if it has not been in use for a long time. An alarm can be triggered by mistake, however, when the wastewater is warm (dripping condensate) or heavily foaming. Do you require more detailed information? Our Service Centre will be happy to help. You can find your personal KESSEL contact on page of this catalog! Complete System Solution In addition to individual lifting and pumping station, KESSEL also offers other systems the drainage of buildings. Do you have a natural gradient to the sewer? World innovation Ecolift the alternative to a standard lifting station with gravity sloped drainage see chapter hybrid lifting systems. Backwater valves for interior and underground installation see chapter backwater valves. Individual Solutions Thanks to the knowledge and possibilities in the field of polyethylene technology KESSEL is not only able to manufacture series products, but also special solutions in accordance with projectspecific requirements. References Over the past decades, KESSEL products have proven themselves countless times in destinations all over the world. Scan the following QR code to directly view our list of references. Which standards must be taken into account? EN 0 Gravity drainage systems inside buildings EN 7 Drainage systems outside buildings EN Backwater valves for buildings EN Drains for buildings with volatile liquid traps EN 00 for buildings 78 Catalogue.
6 Wastewater lifting stations Everything the specialist needs to know Selection criteria lifting stations FOR WASTEWATER CONTAINING RAW SEWAGE Interior installation Exterior installation Minilift F P Aqualift F Compact P Aqualift F P P Aqualift F XL P Aqualift F Ø 00 P AP 0 Ø 800/000 P Aqualift F Ø 000 P Input power 0. kw kw. kw. kw kw.. kw..9 kw Max. pumping height m 9 m m 7 m 9 m m 8 m Pressure pipe diameter 8 mm 0 mm 0 mm 0 mm 0 mm / 90 mm / 90 mm Pump Products see page Macerator 8 Macerator 8 8 Impeller Impeller Macerator Impeller Impeller 0 FOR WASTEWATER WITHOUT SEWAGE Interior installation Exterior installation Minilift P Aqualift S P Aqualift S Ø 00 P Aqualift S Ø 000 P Ecolift XL * P P Input power 00 W 00 W 00 or 000 W 00 or 000 W.. kw Max. pumping height m 7 m 9 m 9 m 7 m Pressure pipe diameter 0 mm 0 mm 0 mm 0 mm 90 mm Pump Impeller Impeller Impeller Impeller Impeller Products see page SmartSelect simply makes planning easier calculation tool for lifting stations at smartselect.kessel.com Catalogue. 79
7 KESSELProduct information Wastewater lifting stations Aqualift F Compact SmartSelect simply makes planning easier calculation tool for lifting stations at smartselect.kessel.com Scan this QR code to directly view the corresponding product video. Compact and powerful lifting stations Single / Twin station 0 liter tank volume Wastewater lifting stations Aqualift F Compact for installation in a concrete floor CHAMBER READY FOR UNDERGROUND INSTALLATION The telescopic upper section makes flexible adaptation to the required installation depth possible. Upper section can be turned, tilted and freely heightadjusted. RETROFITTING Mono systems can be retrofitted and converted into duo systems, even after installation Suitable for use in industrial and residential applications. Installed in the concrete slab / floor, the lifting station is almost invisible thanks to the tilable cover. With technical approval: Z.8 INSTALLATION IN WATERPROOF CONCRETE The compression seal flange in connection with the gasket set guarantees safe sealing against groundwater when the Aqualift F Compact is installed in waterproof concrete. 80 Catalogue.
8 Single station 0 liter tank volume Wastewater lifting stations Aqualift F Compact for free standing installation Twin station 0 liter tank volume Lifting station for wastewater disposal in a single toilet Small lifting station Minilift F for freestanding installation in frost protected rooms INTEGRATED DRAIN FUNCTION The drain contained in the cover drains all surface water. Even in the event of a pipe burst or flooding, the pump discharges water out of the house and into the sewer. MAXIMUM SAFETY THANKS TO CONTROL UNIT WITH SDS The intelligent control unit with integrated selfdiagnosis system SDS and battery buffering continually monitors all electric functions and keeps an electronic operating log which can be read out. If the pump is at a standstill for longer periods, it is automatically activated briefly once a week. ACCESSORY Telemetric system TeleControl available as accessory Art.# 8 70C TOOL FREE PUMP REMOVAL THERMAL INSULATION BELOW THE FLOOR (PERIMETER INSULATION) 0 mm 00 mm 00 mm 0 mm Tiled floor Screed Acoustic insulation mm Waterproof concrete floor max mm Perimeter insulation max. 00 mm Granular subbase Catalogue. 8
9 for wastewater with or without sewage Aqualift F Compact Mono Installation in a concrete slab/floor Ø 0 D Ø Ø Illustration and dimensioned drawing 80 Illustration shows 07 9 Ø 0 Ø 0 Installation area 800 x 800 mm 80 Ø Illustration shows Installation area 700 x 700 mm Products Input power Voltage.0 kw 0 V 8 70C.0 kw 0 V 8 70C Lifting station Aqualift F Compact Mono / Duo for installation in a concrete slab/floor, with recessed cover for onsite tiling and drain Installation depth (D) 90 to 00 mm With odour trap, sealing water height 0 mm With lateral inlet Ø 0 With telescopic upper section for free height and level adjustment, recessed cover for onsite tiling, made of polymer class A, with moisture protective sealing flange. Aqualift F Compact Mono with one removable pump, pressure sensor controlled, with integrated backwater flap Aqualift F Compact Duo with two removable pumps, pressure sensor controlled, with integrated backwater flap With SDS control unit (selfdiagnosis system) for fully automatic pump control, splashwaterprotected (IP ), wall mounted. Pressure connection: / inch outer thread or pressure pipe Ø 0 mm for PVC glued connection or pressure pipe set (accessories Art. # 8 00) Pumping height: max. 9. m, Qmax = 0.9 m/h Voltage: 0 V ~ 0 Hz. Power cable: m. A ventilation pipe must be provided for on site. Lifting station Aqualift F Compact Mono / Duo for freestanding installation With lateral inlet Ø 0 Aqualift F Compact Mono with one removable pump, pressure sensor controlled, with integrated backwater flap Aqualift F Compact Duo with two removable pumps, pressure sensor controlled, with integrated backwater flap With SDS control unit (selfdiagnosis system) for fully automatic pump control, splashwaterprotected (IP ), wall mounted. Pressure connection: / inch outer thread or pressure pipe Ø 0 mm for PVC glued connection or pressure pipe set (accessories Art. # 8 00) Pumping height: max. 9. m, Qmax = 0.9 m/h Voltage: 0 V ~ 0 Hz. Power cable: m. A ventilation pipe must be provided for on site. H [m] Type SPZ 000 Alternating current Current type Voltage 0 V Current.9 A Motor rating P/P 080 W / 0 W RPM 800 min Motor protection integrated Operating mode S 0%.0 kw 0 V 8 7C.0 kw 0 V 8 7C EN 00 (max WC connections) Certification no. Z.8 Minilift F for freestanding installation Products Small lifting station Minilift F made of polymer for freestanding installation in frost protected rooms 7 With pneumatic level control, with activated carbon filter, with dry room monitoring Catalogue. Plugandplay sewage lifting station with chopping device for wastewater disposal in a single toilet. For freestanding setup Q [m/h] 8 0 V H [m] 9 7 EN Q [m/h]
10 for wastewater with or without sewage Installation example Aqualift F Compact Professional advantages Lifting station Pressure pipe set (Art. # 8 00) Extension section The wastewater lifting station Aqualift F Compact takes over the complete basement drainage and pumps wastewater reliably and completely automatically through the pressure pipe set via the backwater level to the higherlevel sewage system. The system is delivered as a readytoinstall chamber which can be installed in waterproof concrete with the aid of the extension section and sealing gasket set. Control is by means of the Comfort control unit with selfdiagnosis system SDS. Installation in the concrete slab/floor makes the Aqualift F Compact the modern alternative to a pump sump. Gasket set Control unit Installation example Aqualift F Compact Plug & play Comfort control unit with selfdiagnosis system SDS for maximum safety. Integrated drain function to drain surface water. Continual drainage even in the event of incoming flood water or a pipe burst. Variable upper section rotatable, tiltable and height adjustable Installation in waterproof concrete. Gasket set (Art. # 8 0) to prevent groundwater infiltration. Elegant optical appearance even for basement rooms which are used as living accommodation: The modern alternative to a pump chamber. TeleControl telemetric system Relaying of full text messages to up to three mobile phones. Chamber ready to be installed, recessed installation in the concrete slab/floor possible with extension section. Scan this QR code to directly view the corresponding product video. Professional advantages Plug & play Comfort control unit with selfdiagnosis system SDS for maximum safety. Lifting station The wastewater lifting station Aqualift F Compact takes over the complete basement drainage and pumps wastewater with and without sewage reliably and completely automatically via the backwater level to the higherlevel sewage system. Control is by means of the Comfort control unit with selfdiagnosis system SDS. Its compact design makes the system ideal for renovation work. Control unit Ideal for later installation, including for renovation work, and for installation in an existing pump sump. Spacesaving Compact lifting station base area only 70 x 70 cm. Ready for connection Assembled ready for connection with horizontal or vertical pressure outlet. Additional inlets Possible connection of additional inlets directly on site. Catalogue. 8
11 Aqualift F Compact Accessories Outer diameter Ø (mm) Ø 7/0 7 0 Extension section with centre flange with elastomer sealing sheet made of NK/SBR Ø 800 mm, incl. screws for article numbers: 8 70C, 8 70C 8 07 Extension section with flange and counter flange for connection to an onsite sealing sheet made of polymer, incl. screws max. extension 0 mm 8 07 Illustration and dimensioned drawing For models made on or after Jan 0 Cover plate, surface water tight Class A With drain Ø 7, includes Multistop odour, foam, rodent and insect stop incl. gasket recessed for onsite tiling, grey, for tile thicknesses of 8 mm with integrated grating, black for article numbers: 8 70C, 8 70C Hair filter made of polymer for article numbers: 8 0 and 8 0 Cover plate, surface water tight Class A made of polymer, incl. gasket Art. # 7 black Ventilation always required when in use! recessed for onsite tiling, grey, for tile thicknesses of 8 mm Ventilation always required when in use! Upper section made of polymer, max. extension 80 mm, height adjustable for article numbers: 8 70C, 8 70C for article numbers: 8 70C, 8 70C 쏗 Transition section Ø 0 / 7 Ø 0 socket / Ø 7 spigot can be used as an upper section, incl. gasket for article numbers: 8 70C, 8 70C, 8 7C, 8 7C 쏗 When multiple extension sections are used make sure that access to valve is still possible! 8 Catalogue , 쏗 쏗 max. 9,7 쏗8, 7 0 for article numbers: 8 70C, 8 70C
12 Aqualift F Compact Accessories Illustration and dimensioned drawing Outer diameter Ø (mm) 80 When multiple extension sections are used make sure that access to valve is still possible! 0 00 Extension section made of polymer, max. extension 80 mm, incl. gasket for article numbers: 8 70C, 8 70C 8070 Gasket set for installation in waterproof concrete 8 0 Consisting of: Counter flange made of polymer, incl. screws, elastomer waterproof membrane in NK/SBR Ø 800 mm Waterproof concrete installation tested by MFPA Leipzig UB./ for article numbers: 8 70C, 8 70C Pressure pipe set Incl. m pressure pipe hose Ø 0 Ø for article numbers: 8 70C, 8 70C, 8 7C, 8 7C Audible alarm 0 m cable length suitable for all control units Potentialfree contact suitable for all control units 0 V: Wastewater station Aqualift F, Wastewater station Aqualift F Compact, Lifting station Aqualift F Mono 0 V Compressor set for use in combination with lifting stations and pumping stations with pressure control: prevents soiling, compensates leaks, avoids condensate forming in the pressure hose, makes operation of systems possible with pressure hose lengths > 0 m, including connection Tpiece, including 0 m pressure hose Retrofit kit alarm float switch for lifting stations Aqualift F Compact Can be combined with 0 V Comfort control units. Comprises a float switch, float switch bracket and m connection cable. 8 0 TeleControl telemetric system for connection to KESSEL Comfort control units 0 Volt and olt. Relaying of full text messages to up to three mobile phones. Without SIM card TeleControl antenna booster for TeleControl telemetric system incl.. m cable to improve reception. With magnetic base Antenna booster extension cable cable length. m 8 79 Catalogue. 8
13 KESSELProduct information Aqualift F and Aqualift F XL for wastewater containing raw sewage SmartSelect simply makes planning easier calculation tool for lifting stations at smartselect.kessel.com Powerful Aqualift F / XL lifting stations 0 liter tank volume 0 liter tank volume Aqualift F for singlefamily homes, apartment blocks or small scale industrial use INLET CONNECTION Size Ø 0 mm or Ø 0 mm selected onsite. Ø 0 Ø 0 PRESSURE SENSOR Pressure sensor controlled pump with nonchokable impeller. ODOURTIGHT 00 % odourtight access cover For industrial, municipal and private use. All the components of the XL lifting stations have been designed as a modular system. It comprises three tank sizes with volumes of 00, 00 and 0 litres. The pumps are available in versions from.00 to.00 Watts. The tanks fit through standard size 800 doors. ADDITIONAL INLETS Ø 0 mm to Ø 00 mm inlets can be easily installed onsite. 8 Catalogue.
14 00 liter tank volume 00 liter tank volume 0 liter tank volume Aqualift F XL for industrial / high volume wastewater disposal CLOSURE VALVE Polymer or cast iron closure valves available as accessory. COMFORT CONTROL UNIT with multilingual digital display (EN, DE, FR, IT, PL, NL) showing current operational status, settings and logbook. TeleControl telemetric system available as accesory. SPUMPS S continuous duty pumps for heavy flow applications (rainwater) with 00 to 00 Watts. TANK BASE integrated sloped base directs wastewater to pump intake and prevents dirt being deposited. Aqualift F XL Art.# 0 INTEGRATED NONRETURN VALVE COMPACT DIMENSIONED BODIES offer large storage capacities but still allow access through 800 mm wide doorways. Catalogue. 87
15 for wastewater with or without sewage Aqualift F Mono 0 liters Illustration and dimensioned drawing Products Voltage SPF Illustration shows Art. # 8 C 7 0 Inlet height 80 Lifting station Aqualift F Mono for freestanding installation in frostfree rooms Tank volume: 0 liters Pump volume: 0 liters Consisting of: Polyethylene storage chamber with cleanout opening. Connection for inlet Ø 0 (inlet height 80 mm) and ventilation Ø 7, connection coupling for manual diaphragm pump Ø. Pressure sensor controlled wastewater pump with nonchokable impeller to pump wastewater with or without sewage (open channel passage 0 mm). Pump is rated submersible (IP 8), pump cable length m. Vertical / horizontal outlet with integrated nonreturn valve, connection coupling Ø 0 with hose section without closure valve (vertical pressure outlet) with closure valve (horizontal pressure outlet) Comfort control unit with mains power ON / OFF switch and multilingual digital display (EN, DE, FR, IT, PL, NL) showing current operational status, settings and logbook; control unit is splash proof (IP ), wall mounted, voltage 0 / at 0 Hz. With potentialfree contact. 0 V 0 V 00S 00S 000S 00S 00S 000S 8 C C Illustration shows Art. # 8 8C S continuous duty pumps available upon request Total weight approx. kg. LGA Typetested and monitored guaranteed with tested quality EN 00 Aqualift F Duo 0 liters Illustration shows Art. # 8 8C Inlet height 00 Lifting station Aqualift F Duo for freestanding installation in frostfree rooms Tank volume: 0 liters Pump volume: 0 liters Consisting of: Polyethylene storage chamber with cleanout opening. Connection for inlet Ø 0 (inlet height 00 mm) and ventilation Ø 7, connection coupling for manual diaphragm pump Ø. Pressure sensor controlled twin wastewater pumps with nonchokable impeller to pump wastewater with or without sewage (open channel passage 0 mm). Pump is rated submersible (IP 8), pump cable length m. Vertical/ horizontal outlet with integrated nonreturn valve, connection coupling Ø 0 with hose section without closure valve (vertical pressure outlet) with closure valve (horizontal pressure outlet) Comfort control unit with mains power ON / OFF switch and multilingual digital display (EN, DE, FR, IT, PL, NL) showing current operational status, settings and logbook; control unit is splash proof (IP ), wall mounted, voltage 0 / at 0 Hz. With potentialfree contact. S continuous duty pumps available upon request Total weight approx. 8 kg. Products 0 V 00S 8 8C 00S S V 00S 00S 000S 8 9C Illustration shows Art. # 8 9C 88 Catalogue. LGA Typetested and monitored guaranteed with tested quality EN 00
16 for wastewater with or without sewage Installation example Aqualift F Professional advantages Quality and reliability are our strengths: Spacesaving installation thanks to the possibility of inlet connection Ø 0 from above and simple routing of the pressure pipe in the corner of the room. Simple connectandgo connection with horizontal or vertical pressure outlet Easy to retrofit with the suitable closure valve. Variable connection possibilities for further inlets directly on site. 0 Volt olt Lifting station H [m] 0 8 SPF 00 Qmin for Ø 90 mm* Qmin for Ø 0 mm* SPF 00 SPF * according to EN 0 Q [m /h] Pressure pipe The lifting station Aqualift F is ideal for freestanding installation in frostprotected areas. The compact and powerful lifting station with control unit disposes of wastewater with or without sewage reliably and fully automatically through the pressure pipe to the higherlevel sewage system. Comfort control unit User friendly navigation in multiline display With selfdiagnosis system SDS and memory function for the next service Displays current operational status Simple setting of parameters relevant for the function Operating hours counter Optional forwarding of alarm and general fault signals via a GSM interface Multilingual display (EN, DE, FR, IT, PL, NL) Type Input Power (P) Power (P) Voltage Frequency Amperage Fuses Cable connections Media temperature Weight (Pump) Protection Operating mode Rpm SPF 00. kw. kw 0 V 0 Hz 7. A A surgeproof 0 m Length, 7 x. mm 0 C kg IP 8 S 0 % power on duration.70 SPF 00. kw. kw 0 Hz.7 A x A surgeproof 0 m Length, 7 x. mm 0 C kg IP 8 S 0 % power on duration. SPF 000. kw.7 kw 0 Hz. A x A surgeproof 0 m Length, 7 x. mm 0 C kg IP 8 S 0 % power on duration.8 Catalogue. 89
17 for wastewater with or without sewage Aqualift F XL 00 liters Products Illustration and dimensioned drawing Voltage SPF Illustration shows Art. # 09 Ø 7 Ø 0 Ø Lifting station Aqualift F XL for free standing installation Tank volume: 00 liters Pump volume: 0 liters Lifting station with one/two SPF pumps for wastewater with or without sewage for freestanding installation in frostfree rooms Consisting of: Polyethylene storage chamber with cleanout opening. Spigots for vertical inlet Ø 0 mm/0 mm, ventilation Ø 7 mm and for manual diaphragm pump Ø mm. Horizontal inlet Ø 0 mm to Ø 00 mm by sawing. Pressure sensor controlled single / twin wastewater pump with nonchokable impeller to pump wastewater with or without sewage (open channel passage 0 mm). Pump is rated submersible (IP 8), pump cable length m. Operating mode: S or S Vertical/ horizontal outlet with integrated nonreturn valve, with/without closure valve (provided loose), with hose section or flange. Single pump lifting stations: without closure valve (vertical pressure outlet) with plastic closure valve (horizontal pressure outlet Ø 0) with cast iron closure valve Single pump lifting stations: 0 V 0 V 00S 00S 00S 00S 000S 000S 00S 00S 00S 00S Twin pump lifting stations: 0 V 0 V 00S 00S 00S 00S 000S 000S 000S 00S 00S 00S 00S Twin pump lifting stations: without closure valve (vertical pressure outlet) with plastic closure valve (horizontal pressure outlet Ø 0) with cast iron closure valve (vertical pressure outlet DN 80) Illustration shows Art. # 07 Comfort control unit with mains power ON / OFF switch and multilingual digital display (EN, DE, FR, IT, PL, NL) showing current operational status, settings and logbook; control unit is splash proof (IP ), wall mounted, voltage 0 V or at 0 Hz. With potentialfree/bms contact (optional at 0 V). Ø 7 Ø 0 Ø 0 EN H [m] Qmin for Ø 90 mm* 00 0 Qmin for Ø 0 mm* 70 0 SPF 00 SPF 00 SPF 00 SPF SPF Q [m /h] 90 Catalogue.
18 for wastewater with or without sewage Aqualift F XL 00 liters Products Illustration and dimensioned drawing Voltage SPF 70 Illustration shows Art. # Ø 0 Ø 0 Ø Lifting station Aqualift F XL for free standing installation Tank volume: 00 liters Pump volume: 7 liters Twin station with two SPF pumps for wastewater with or without sewage for freestanding installation in frostfree rooms Consisting of: Polyethylene storage chamber with cleanout opening. Spigots for vertical inlet Ø 0 mm/0 mm, ventilation Ø 7 mm and for manual diaphragm pump Ø mm. Horizontal inlet Ø 0 mm to Ø 00 mm by sawing. Pressure sensor controlled single / twin wastewater pumps with nonchokable impeller to pump wastewater with or without sewage (open channel passage 0 mm). Pump is rated submersible (IP 8), pump cable length m. Operating mode: S or S Vertical/ horizontal outlet with integrated nonreturn valve, with/without closure valve (provided loose), with hose section or flange. Single pump lifting stations: without closure valve (vertical pressure outlet) with plastic closure valve (horizontal pressure outlet Ø 0) with cast iron closure valve Single pump lifting stations: 0 V 00S V 00S 0 00S 07 00S S 0 000S 07 00S 0 00S 0 00S S 079 Twin pump lifting stations: 0 V 0 V 00S 00S 00S 00S 000S 000S 000S 00S 00S 00S 00S Twin pump lifting stations: without closure valve (vertical pressure outlet) with plastic closure valve (horizontal pressure outlet Ø 0) with cast iron closure valve (vertical pressure outlet DN 80) Illustration shows Art. # Comfort control unit with mains power ON / OFF switch and multilingual digital display (EN, DE, FR, IT, PL, NL) showing current operational status, settings and logbook; control unit is splash proof (IP ), wall mounted, voltage 0 V or at 0 Hz. With potentialfree/bms contact (optional at 0 V). Ø 0 Ø 0 Ø 7 EN H [m] Qmin for Ø 90 mm* Qmin for Ø 0 mm* 0 SPF 00 SPF SPF 00 SPF 00 SPF Q [m /h] Catalogue. 9
19 for wastewater with or without sewage Aqualift F XL 0 liters Illustration and dimensioned drawing Products Voltage SPF Illustration shows Art. # 7 Ø 0 Ø 0 Ø 7 07 Lifting station Aqualift F XL for free standing installation Tank volume: 0 liters Pump volume: 0 liters Twin station with two SPF pumps for wastewater with or without sewage for freestanding installation in frostfree rooms Consisting of: Polyethylene storage chamber, with air pressure level detector, cleanout opening. Spigots for vertical inlet Ø 0 mm/0 mm, ventilation Ø 7 mm and for manual diaphragm pump Ø mm. Horizontal inlet Ø 0 mm to Ø 00 mm by sawing. Pressure sensor controlled twin wastewater pumps with nonchokable impeller to pump wastewater with or without sewage (open channel passage 0 mm). Pump is rated submersible (IP 8), pump cable length m. Operating mode: S or S Twin pump lifting stations: 000S 000S 000S 8 00S 00S 7 00S 08 00S Vertical/ horizontal outlet with integrated nonreturn valve, with/without closure valve (provided loose), with hose section or flange without closure valve (vertical pressure outlet) with plastic closure valve (horizontal pressure outlet Ø 0) with cast iron closure valve (vertical pressure outlet DN 80) 089 Comfort control unit with mains power ON / OFF switch and multilingual digital display (EN, DE, FR, IT, PL, NL) showing current operational status, settings and logbook; control unit is splash proof (IP ), wall mounted, voltage at 0 Hz. With potentialfree/bms contact. EN 00 9 Catalogue.
20 for wastewater with or without sewage Installation example Aqualift F XL Professional advantages Inlet connection Size Ø 0 mm or Ø 0 mm selected onsite Ø 0 Ø 0 H [m] 0 0 Lifting station SPF 00 SPF 00 Qmin for Ø 90 mm* Qmin for Ø 0 mm* Grease separator EasyClean The wastewater is pumped by the Aqualift F XL lifting station fully automatically upwards via the backwater loop to the sewage system. A greater pumping capacity if more wastewater occurs is guaranteed by a second pump switching on automatically. Long pump service life thanks to alternating operation. The lifting stations of the Aqualift F XL series are particularly suitable for industrial and municipal applications, such as downstream from a grease separator. SPF 000 SPF 00 SPF 00 Additional inlet connections onsite Inlets from size Ø 0 mm to Ø 00 mm inlets can be easily installed. Polymer gate closure valves and fittings for SPF 00, 00, 000 models. Cast iron gate closure valves and fittings for SPF 00 and 00 models. Cast iron systems also available for other pump models where excessive return pressures are expected Compact dimensioned bodies offer large storage capacities but still allow access through 800 mm wide doorways. Single or Twin Pump Lifting Stations Includes digital display control unit and nonreturn valve. 0 Volt olt Comfort control unit User friendly navigation in multiline display With selfdiagnosis system SDS and memory function for the next service Displays current operational status Simple setting of parameters relevant for the function Operating hours counter Optional forwarding of alarm and general fault signals via a GSM interface Multilingual display (EN, DE, FR, IT, PL, NL) * according to EN Q [m /h] Type Input Power (P) Power (P) Voltage Amperage SPF 00. kw. kw 0 V 7. A SPF 00. kw. kw.7 A SPF 000. kw.7 kw. A SPF 00. kw.7 kw 7. A SPF 00.7 kw.7 kw 9. A Operating mode Weight S: 00 % S: 0 % / 0% power on duration S / S: 0% 99 kg S / S: 0% 98 kg S / S: 0% 88 kg S / S: 0% 89 kg S: 0% kg Catalogue. 9
21 Aqualift F / Aqualift F XL / Aqualift F Duo XXL Accessories Illustration and dimensioned drawing Outer diameter Ø (mm) Audible alarm 0 m cable length suitable for all control units 0 Potentialfree contact suitable for all control units 0 V: Wastewater station Aqualift F, Lifting station Aqualift F Mono 0 V 8007 Compressor set for use in combination with lifting stations and pumping stations with pressure control: prevents soiling, compensates leaks, avoids condensate forming in the pressure hose, makes operation of systems possible with pressure hose lengths > 0 m, including connection Tpiece, including 0 m pressure hose Closure valve for all lifting stations Aqualift F Closure valve made of polymer for installation on inlet side (no pressure) for all lifting stations Aqualift F Ø 0 Ø 0 Ø Manual diaphragm pump / inch for manually pumping wastewater. With a ball valve on inlet and outlet side / inch 8 80 Sound absorption soundabsorbing underlay mat (0 mm thick) for lifting stations Aqualift F Mono for lifting stations Aqualift F Duo Pipe sealing gasket (EPDM) Use KESSEL hole saw when drilling. for lifting stations Aqualift F Ø 0 Ø 7 Ø 0 Ø Ø 0 Ø Hole saw for drilling lateral surfaces for inlets and outlets Ø 0, 7, 0, and 0 (Saw blade holder Ø = 90 mm) 0 00 Ø 00 (Use a drill with at least 000 W) Catalogue.
22 Aqualift F XL Accessories Illustration Outer diameter Ø (mm) Alarm float switch upgrade set for Aqualift F XL lifting station For use with 0 V and Comfort control units. Consists of float switch, support plate, cover and meter connection cable. 8 0 Alarm float switch upgrade set for Aqualift F and F Duo lifting stations For use with 0 V and Comfort control units. Consists of float switch, support plate, cover and meter connection cable. 8 0 TeleControl telemetric system for connection to KESSEL Comfort control units 0 Volt and olt. Relaying of full text messages to up to three mobile phones. Without SIM card. TeleControl antenna booster for TeleControl telemetric system incl.. m cable to improve reception. With magnetic base Antenna booster extension cable cable length. m 8 79 Backflow preventer in cast iron DN with DN 80 flange according to DIN 0; Backflow preventer with flap and flap opening lever Flange adaptor from DN 80 to DN 00 in PE, flanges according to DIN For use with PE and SML pressure pipes, includes two gaskets Cast iron connection adaptor for connection from Aqualift F XL to onsite pressure pipe DN 80 (OD 90 mm) DN 00 (OD 0 mm) Ø 90 Ø For use with PE and SML pressure pipes, with DIN 0 flange, includes single gasket Catalogue. 9
23 Aqualift F XL Accessories Illustration Outer diameter Ø (mm) Flexible pressure pipe connection Length 00 mm for PE and SML pipe connections For use with KESSEL Aqualift F, Aqualift F XL lifting stations Ø 90 Ø for cast iron pipe connections For use with KESSEL Aqualift F XL lifting stations Ø 00 Ø Flange adaptor from DN 80 to DN 00 in cast iron 8 08 Flange according to DIN 0 For use with cast iron pressure pipes Cast iron connection adaptor in cast iron For connection from Aqualift F XL to onsite pressure pipe DN 80 (OD 98 mm) DN 00 (OD 8 mm) For use with cast iron pressure pipes, with DIN 0 flange PN, includes single gasket Ø 98 Ø Gate closure valve in cast iron DN With DN 80 flange according to DIN 0, gate closure valve including closure wheel YCoupling in cast iron Ø With DN 80 (OD 80 mm) flange according to DIN 0, Ycoupling for use with Aqualift F XL twin pump lifting stations Sealing gasket (rubber) according to DIN 0 DN 80 DN For pressure pipe connections 9 Catalogue.
24 Aqualift F XL Accessories Illustration Outer diameter Ø (mm) Closure valve in PE Ø vertical, DN 90, for the pressure pipe of KESSEL lifting stations with plastic fitting Closure valve with flange adaptor in PE Ø vertical, DN 90, for the pressure pipe of KESSEL lifting stations with plastic fitting, with screwed flange adapter Flange adaptor DN 80 in PE DN from KESSEL fitting to standard flange DN 80 Connection flange in PE Ø 90 Ø for KESSEL plastic fittings Catalogue. 97
25 KESSELProduct information Wastewater lifting station Aqualift S and Minilift SmartSelect simply makes planning easier calculation tool for lifting stations at smartselect.kessel.com Scan this QR code to directly view the corresponding product video. The hygienic alternative to a pump sump Single or twin pump lifting stations with additional surface drainage Aqualift S for installation in a concrete slab/floor Aqualift S INSTALLATION IN THE CONCRETE SLAB/FLOOR Installation set with integrated drain function for drainage of surface water. INSTALLATION Telescopic upper section with shallow waterproofing flange, recessed cover for onsite tiling and integrated drain function ADDITIONAL SAFETY Odour, foam, rodent and insect stop Multistop available as accessory Aqualift S lifting stations for installation in a concrete slab / floor dispose of penetrating high water or surface water resulting from burst pipes through fully automatic pump control. Aqualift S lifting stations for freestanding installation are particularly suitable for connection to grease separator systems. Minilift lifting stations compact lifting stations for renovation work. CONNECTIONS Connection of optional inlets to drain body of Ø 0, above the compression flange and in the extension section up to Ø 7. FLEXIBLE INSTALLATION New extension section with central flange, counterflange and elastomer waterproofing sheet optional as protection against water load for installation in waterproof concrete. 98 Catalogue.
26 Twin pump system for connection downstream from small grease separator systems Lifting station Aqualift S for freestanding installation Single pump systems Ideal for renovation work Minilift for freestanding installation / installation in concrete slab/floor OPTICAL APPEARANCE Elegant optical appearance even for cellar rooms which are used as living accommodation: The uptodate alternative to the pump chamber. Aqualift S FREE STANDING INSTALLATION Particularly suitable as a lifting station for connection to small grease separator systems (with maximum pumping height of m). SNAP CLOSURE Pump removal without tool thanks to onehanded snap closure, also suitable for mobile use. CONNECTIONS Connection of further inlets Ø 0 and Ø 7. Minilift The mobile Minilift lifting station for freestanding installation fits under any sink; a washing machine, shower or other inlets can all be connected at the same time. CLEANING AND MAINTENANCE Pump removal without tool thanks to onehanded snap closure, also suitable for mobile use. SELFDIAGNOSIS SYSTEM SDS Plugandplay 0 Volt control units with selfdiagnosis system SDS. Comfort version with menu navigation in six languages with multiline display. Chapter Modems and control units see page 8 FURTHER INLETS Connection of further inlets Ø 0 and Ø 7 directly on site. Catalogue. 99
27 for wastewater without sewage Aqualift S Installation in a concrete slab/floor Illustration and dimensioned drawing D 7 0 Ø 0 Lifting station Aqualift S for wastewater without sewage, made of polymer For installation in a concrete slab/floor, Installation depth (D) 8 mm to mm With telescopic upper section for continuous height and level adjustment, recessed cover for onsite tiling, made of polymer, class A, with moisture protective sealing flange, with removable, float switch controlled pump and integrated backwater flap. Pressure connection: / inch outer thread, Pressure pipe Ø 0 mm for PVC glued connection or pressure pipe set. max. pumping height: 8 m Voltage: 0 V ~ 0 Hz Input power: 0.8 kw Pump on level: 00 mm Pump off level: 8 mm Max. particle size: 0 mm Power cable: m Weight: ca. 9 kg Outer diameter Ø (mm) Ø 0 Products 8 00 Version with powerful GTF 000 pump on request individual@kessel.de Installation area 700 x 700 mm Optional: Hair filter page 0 Installation area 700 x 700 mm LGA Typetested and monitored guaranteed with tested quality EN 00 Aqualift S Tronic / Aqualift S Duo Installation in a concrete slab/floor Products Illustration shows Art. # 8 0C D Ø 90 Ø 0 8 Lifting station Aqualift S Tronic / Aqualift S Duo for wastewater without sewage, made of polymer For installation in a concrete slab/floor, Installation depth (D) 8 mm to mm With telescopic upper section for continuous height and level adjustment, recessed cover for onsite tiling, made of polymer, class A, with moisture protective sealing flange, integrated backwater flap. Pressure connection: / inch outer thread, Pressure pipe Ø 0 mm for PVC glued connection or pressure pipe set. Max. particle size: 0 mm. max. pumping height: 7 m. Voltage: 0 V ~ 0 Hz. Aqualift S Tronic with removable, pressure sensor controlled pump, optical alarme probe, Input power: 0.8 kw. Power cable: m. Weight: approx. 9 kg. Aqualift S Duo with two removable, pressure sensor controlled pumps, Input power: x 0.8 kw. Power cable: m. Weight: approx. kg. Comfort control unit with multilingual digital display (EN, DE, FR, IT, PL, NL) showing current operational status, settings and logbook, IP splash proof control unit housing, for wall mounting, operational voltage 0 V DC, with potential free contact (BMS) connections. Optional: Audible alarm page 07 Hair filter page 0 Ø 0 Ø 0 8 0C 8 0C LGA Typetested and monitored guaranteed with tested quality EN Catalogue.
28 for wastewater without sewage Installation example Aqualift S Professional advantages Chamber ready to be installed, recessed installation in the concrete slab/floor possible with extension section. D max. = 800 mm from 8 mm 00 H D 0 8 Extension section Art. # 8 07 Lifting station Aqualift S Pressure pipe set (Art. # 8 00) Integrated drain H [m] 7 7Q [m /h] Gasket set Control unit The lifting station Aqualift S pumps wastewater without sewage through the pressure pipe set upwards via the backwater loop to the sewage system. In addition, surface water can be drained via the integrated drain following a burst pipe or high water penetration and be disposed of by the pump. The readytoinstall chamber can also be installed in waterproof concrete with the aid of the sealing gasket set. The system is controlled by means of the control unit provided. H = 8 8 mm Integrated drain function to drain surface water. Continual drainage even in the event of incoming flood water or a pipe burst. Variable upper section rotatable, tiltable and height adjustable Installation in waterproof concrete. Gasket set (Art. # 8 0) to prevent groundwater infiltration. Elegant optical appearance even for basement rooms which are used as living accommodation: The uptodate alternative to the pump chamber. Optional safety Cover with drain and Multistop odour, foam and rodent trap optional. Current type Alternating current Voltage 0 V Current. A Power P / P 80 W / 0 W RPM 800 min Motor protection integrated Plug Schuko m cable 0 Volt Comfort control unit User friendly navigation in multiline display With selfdiagnosis system SDS and memory function for the next service Displays current operational status Simple setting of the parameters relevant for the function Operating hours counter Optional forwarding of alarm and general fault signals via a GSM interface Multilingual display (EN, DE, FR, IT, PL, NL) Scan this QR code to directly view the corresponding product video. Catalogue. 0
29 for wastewater without sewage Aqualift S for freestanding installation Illustration and dimensioned drawing Ø Ø Twin lifting station Aqualift S made of polymer for freestanding installation With twin removable, pressure sensor controlled pumps, integrated backwater flap, Inlet Ø 0, ventilation connection Ø 7 (incl. pipe sealing gasket), Comfort control unit with multilingual digital display (EN, DE, FR, IT, PL, NL) showing current operational status, settings and logbook, IP splash proof control unit housing, for wall mounting, operational voltage 0 V DC, with potential free contact (BMS) connections. Pressure connection: / inch outer thread or pressure pipe Ø 0 mm for PVC glued connection. Inlet height: 0 mm Total height: 70 mm, Ø 00 mm Voltage: 0 V ~ 0 Hz Max. chamber size: l max. pumping height: 8 m Input power: x 0.8 kw Power cable: m Weight: ca. kg Ideal for connection downstream from small grease separator systems. Outer diameter Ø (mm) Ø 0 Products 8 C Version with powerful GTF 000 pump on request individual@kessel.de LGA Typetested and monitored guaranteed with tested quality EN 00 0 Catalogue.
30 for wastewater without sewage Installation example Aqualift S Professional advantages Connection of several inlets Alongside the standard inlet Ø 0, further inlets (Ø 0, Ø 7) can be connected following scoring using a hole saw (Art. # 0 0). Long pump service life thanks to alternating operation. Particularly suitable as a lifting station connected downstream from grease separator systems (nominal size, and with maximum pumping height of m). The second pump is switched on automatically where there is increased wastewater occurrence. Lifting station Aqualift S H [m] 7 Grease separator EasyClean The Aqualift S lifting station is particularly suitable for connection to grease separator systems of the nominal sizes NS NS. A greater pumping capacity if more wastewater occurs is guaranteed by a second pump switching on automatically. Monitoring and control of the system are managed by the Comfort control unit. 0 Volt Comfort control unit User friendly navigation in multiline display With selfdiagnosis system SDS and memory function for the next service Displays current operational status Simple setting of the parameters relevant for the function Operating hours counter Optional forwarding of alarm and general fault signals via a GSM interface Multilingual display (EN, DE, FR, IT, PL, NL) 7Q [m /h Current type Alternating current Voltage 0 V Current. A Power P / P 80 W / 0 W RPM 800 min Motor protection integrated Plug Schuko m cable Catalogue. 0
31 for wastewater without sewage Minilift Installation in a concrete slab/floor Illustration and dimensioned drawing 90 7 Lifting station Minilift made of polymer for underground installation With removable, float switch controlled pump, backwater flap, grating and cover plate class L. Pressure connection: / inch outer thread, Pressure pipe Ø 0 mm for PVC glued connection or pressure pipe set. Pumping height:. m Voltage: 0 V ~ 0 Hz Input power: 0. kw Power cable: m Max. particle size: 0 mm Pump on level: 80 mm Pump off level: 80 mm Outer diameter Ø (mm) Ø 0 Products 8 70 Connection Version with powerful KTP 00 electrical cable 8x pump on request 9x90 individual@kessel.de Installation area 00 x 00 mm LGA Typetested and monitored guaranteed with Minilift for freestanding installation tested quality EN 00 Lifting station Minilift made of polymer for freestanding installation With removable, float switch controlled pump and backwater flap. Pressure connection: / inch outer thread or pressure pipe Ø 0 mm for PVC glued connection Pumping height:. m Voltage: 0 V ~ 0 Hz Input power: 0. kw Power cable: m Max. particle size: 0 mm Pump on level: 80 mm Pump off level: 80 mm With activated charcoal filter Ø 0 Products 8 0 Version with powerful KTP 00 or GTF 000 pump on request individual@kessel.de LGA Typetested and monitored guaranteed with tested quality EN 00 0 Catalogue.
32 for wastewater without sewage Installation example Minilift Professional advantages Chamber ready to be installed, recessed installation in the concrete slab/floor possible with extension section (Art. # 00). Integrated drain function to drain surface water. Continual drainage even in the event of incoming flood water or a pipe burst. Toolfree pump removal The onehand snap closure feature means that no tools are required to remove the pump for cleaning and maintenance. Lifting station Wastewater pump Extension section (Art. # 00) The lifting station Minilift is made up of a chamber for installation in the concrete slab/floor, a 00 W wastewater pump, a closed cover plate and a slotted cover. The chamber can be concreted in directly during foundation work or inserted into a recess later and then connected. Any installation depths can be realised using the extension section. H [m] Q [m /h] Installation example Minilift Current type Alternating current Voltage 0 V Current.7 A RPM 800 min Motor protection integrated Professional advantages Plug Schuko m cable Lifting station H [m] Q [m /h] Wastewater pump The Minilift lifting station fits easily underneath any washbasin; it can also be connected to a washing machine, shower or other inlets. The station is equipped with a 00 W wastewater pump with a float control. The pressure pipe can be a PVC pipe Ø 0 mm. It is also possible using a screw connection / inch to connect the pressure pipe to the lifting station. Current type Alternating current Voltage 0 V Current.7 A Spacesaving The compact dimensions of the Minilift lifting station allow problemfree installation under a standard sink. Toolfree pump removal The onehand snap closure feature means that no tools are required to remove the pump for cleaning and maintenance. Connection of further inlets Alongside the standard inlet in the cover, inlets can be attached at the side through the prescored areas. Ventilation No further ventilation pipes are required thanks to the integrated activated carbon filter. RPM 800 min Motor protection integrated Plug Schuko m cable Catalogue. 0
33 Aqualift S Accessories Illustration and dimensioned drawing 08 0 For models made on or after Jan 쏗 Hair filter made of polymer for article numbers: 8 0 and Upper section made of polymer, max. extension 80 mm, height adjustable for article numbers: 8 00, 8 0C, 8 0C recessed for onsite tiling, grey, for tile thicknesses of 8 mm Ventilation always required when in use! 8 0 with integrated grating, black 8 0 Extension section with centre flange with elastomer sealing sheet made of NK/SBR Ø 800 mm, incl. screws for article numbers: 8 00, 8 0C, 8 0C 8 07 Extension section with flange and counter flange for connection to an onsite sealing sheet made of polymer, incl. screws max. extension 0 mm for article numbers: 8 00, 8 0C, 8 0C 쏗 8 0 Cover plate, surface water tight Class A With drain Ø 7, includes Multistop odour, foam, rodent and insect stop incl. gasket recessed for onsite tiling, grey, for tile thicknesses of 8 mm with integrated grating, black 8 Odour trap 0 mm seal water height For cover plate Art. # 8 0. Ventilation always required when in use! for article numbers: 8 00, 8 0C, 8 0C 쏗00 Cover plate, surface water tight Class A With drain Ø 7, incl. gasket recessed for onsite tiling, grey, for tile thicknesses of 8 mm for article numbers: 8 00, 8 0C, 8 0C 8 Outer diameter Ø (mm) Cover plate, surface water tight Class A made of polymer, incl. gasket Art. # 7 black Ventilation always required when in use! 0 0 쏗 for article numbers: 8 00, 8 0C, 8 0C 쏗 When multiple extension sections are used make sure that access to valve is still possible! 0 00 쏗 80 쏗 0 Catalogue. for article numbers: 8 00, 8 0C, 8 0C Extension section made of polymer, max. extension 80 mm, incl. gasket for article numbers: 8 00, 8 0C, 8 0C When multiple extension sections are used make sure that access is still possible!
34 Aqualift S / Minilift Accessories Illustration and dimensioned drawing Outer diameter Ø (mm) Gasket set for installation in waterproof concrete 8 0 Waterproof concrete installation tested by MFPA Leipzig UB./ Consisting of: Counter flange made of polymer, incl. screws, elastomer waterproof membrane in NK/SBR Ø 800 mm for article numbers: 8 00, 8 0C, 8 0C Cover plate Class A grey black 000 W 000S for article numbers: 8 70 Cover with grating Class A grey black 000W 000S for article numbers: 8 70 Extension section made of polymer Height = 0 mm for deep installation 00 for article numbers: Alarm with electrode probe with optical probe for article numbers: Audible alarm 0 m cable length suitable for all control units with SDS function: Aqualift S Tronic 0 Potentialfree contact suitable for all control units with SDS function: Aqualift S Tronic 8007 Pressure pipe set incl. m pressure pipe hose Ø 0 Ø for article numbers: 8 00, 8 0C, 8 0C Hole saw Ø 0, 7, 0 (Saw blade holder Ø = mm) 0 0 Hole saw Ø 0, 7, 0, and 0 (Saw blade holder Ø = 90 mm) 0 00 Pipe sealing gasket (EPDM) Use KESSEL hole saw when drilling. for article numbers: 8 00, 8 0C, 8 0C, 8 0, 8 C Ø 0 Ø 7 Ø 0 Ø Ø Cable extension set (for probe) 0 m cable length Cable extension set (for pump) 0 m cable length Note: Cable extensions Aqualift S 8 0: x optical probe, x pump 8 0: x optical probe, x pump 8 : x optical probe, x pump Catalogue. 07
35 KESSELProduct information and pumping stations Aqualift F XL, Aqualift F and Aqualift S SmartSelect simply makes planning easier calculation tool for lifting stations at smartselect.kessel.com Fig. Pumping stations for underground installation Use as living space Backwater level Lifting station outside the building in the KESSEL system chamber SYSTEM ADVANTAGES / INSTALLATION CONVENIENCE Expensive living or useful space is not lost. No pump noises in the building. No odour pollution and soiling in the building (Fig. ). SAFETY High pumping volume and additional reserve volume if the system should fail e.g. in the event of a power cut. 0year guarantee for PE material. CONTROL UNITS Plugandplay control units with selfdiagnosis system SDS and Polyethylene Warranty Polyethylene Warranty 0 Years monthly selftest. Comfort version with multiline display for operating state and maintenance instructions (Fig. ). INSTALLATION Straightforward installation thanks to low weight of the individual chamber parts with safe fastening technology (Fig. ) and variable upper section for adaptation to the ground level (Fig. ). Installing lifting stations within the home often wastes valuable living/storage space as well as potentially causing nuisance operational noise. New solutions are now available giving the home/ building owner decisive advantages. 08 Catalogue.
36 Chamber system Ø 000 mm Aqualift F XL for wastewater with or without sewage Chamber systems Ø 00 / 800 / 000 mm Aqualift F for wastewater with or without sewage Chamber systems Ø 00 / 000 mm Aqualift S for wastewater without sewage SELECTION CRITERIA LIFTING / PUMPING STATIONS Wastewater Aqualift F XL Ø 000 mm with sewage Aqualift F Ø 00 mm with sewage Aqualift F Ø 800/000 mm with sewage Aqualift F Ø 000 mm with sewage Aqualift S Ø 00 mm without sewage Aqualift S Ø 000 mm without sewage Pump SPF SPZ 000 AP 0 TPF KTP 00 / GTF 000 KTP 00 / GTF 000 Power (P)..7 kw 0. kw 0.7 kw. /.9 kw 0. / 0.7 kw 0. / 0.7 kw Pumping height 7 / 0 m 9 m m / 0 m 7 / 9 m 7 / 9 m Pressure pipe connection Ø 90 mm 0 mm / 90 mm / 90 mm 0 mm 0 mm Installation depth mm mm 80 0 mm 0 0 mm mm 0 0 mm ATEX* Products see page * The product is suitable for installation in potentially explosive atmospheres P Catalogue. 09
37 Pumping stations for wastewater with or without sewage Aqualift F XL for minimum installation depth Illustration and dimensioned drawing Products Voltage 77 Engineering systems base with welded on chamber ring and tapered section Ø 800 mm for minimum installation depth Aqualift F XL Mono / Duo pumping station for wastewater with sewage and wastewater without sewage Tank volume approx. liter Pumping volume approx. 0 liter For installation in a concrete slab or outdoor underground installation in combination with an upper section Handles groundwater depth up to 000 mm Mono version with one SPF pump with Comfort control unit including backflow preventer and closure valve on pressure pipe side Duo version with two SPF pumps with Comfort control unit including backflow preventer and closure valve on pressure pipe side Ø 9 Ø Inlet Ø 0 mm / pressure pipe connection Ø 80 mm Pump SPF Mono versions 00S 0 V 00S 000S 00S Duo versions 00S 0 V 00S 000S 00S 00S 0 V 00S 000S 00S Welded PE pipe is to be used for the pressure pipe See below for upper sections / covers required SmartSelect simply makes planning easier calculation tool for lifting stations at smartselect.kessel.com DT DT Ø DT DT Ø Ø D Ø Catalogue. Height engineering systems base from base of inlet to top Type without watertight flange with watertight flange without watertight flange with watertight flange without watertight flange without watertight flange D To be ordered separately: Upper sections Ø 800 mm made of plastic with covers: Ø Height of upper section (D) Illustration 77 mm Depth of wastewater pipe according plan Approval pending made of stainless steel, square, class A/L tileable D: min. max. mm tileable D: min. 8 max. mm nontileable D: min. 0 max. 99 mm nontileable D: min. 7 max. mm Slipresistant made of stainless steel, square class B D: min. 7 max. mm class D D: min. 7 max. mm
38 Pumping stations for wastewater with or without sewage Underground installation outside buildings Professional advantages Pumping station Aqualift F XL Engineering systems chamber Pressure pipe Aqualift F XL disposes of large quantities of wastewater and is thus suitable not only for the classical application case of residential buildings, but also for commercial and industrial applications. The pumping station is available as a Mono or Duo station for wastewater with or without sewage. The tank volume is litres, the maximum pumping volume is approx. 0 litres. Aqualift F XL is equipped with pneumatic level measurement and an alarm sensor. The pumping station is suitable for installation in the ground or in concrete floors. The engineering chamber is suitable for installation in groundwater up to 000 mm. It is made up of modular chamber rings which are available in heights of 0 mm and 00 mm. Control units with selfdiagnosis system SDS for monitoring pump and battery buffering with monthly selftest. Comfort version with multiline display for operating state and maintenance instruction as well as userfriendly menu guidance in six languages. Pneumatic level measurement and an alarm sensor for double safety With inlet x elbow Ø 0 additional prescored areas Ø 0 x Ø % airtight screwed cleaning opening Tank floor resistant to groundwater depths up to 000 mm Fitting with integrated backwater preventer and aeration device for simple bleeding of the pressure pipe Closure valve with safety hoop to prevent unintentional closing Pumps (Mono/Duo) in different capacity classes High pumping volume approx. 0 litres Pump type: SPF 00S 0 % SPF 00S for continuous duty (e.g. rainwater) Pumping capacity: max. 8 m³/h Pumping height: max. 7 m SPF 000S 0 % SPF 000S for continuous duty (e.g. rainwater) Pumping capacity: max. 7 m³/h Pumping height: max. m A [m] 0 SPF 00S 0 % SPF 00S for continuous duty (e.g. rainwater) Pumping capacity: max. 0 m³/h Pumping height: max. 8 m SPF 00S 0 % SPF 00S for continuous duty (e.g. rainwater) Pumping capacity: max. m³/h Pumping height: max. 0 m 0 SPF 00 SPF 00 SPF 00 SPF Q [m /h] Catalogue.
39 Pumping stations for wastewater with or without sewage Aqualift F XL for installation depth up to m Products Illustration and dimensioned drawing Voltage Pump SPF Engineering systems base with welded on chamber ring for installation depth up to m Aqualift F XL Mono / Duo pumping station for wastewater with sewage and wastewater without sewage Tank volume approx. liter Pumping volume approx. 0 liter For installation in a concrete slab and for outdoor underground installation in combination with system chamber Handles groundwater depth up to 000 mm Inlet Ø 0 / discharge outlet Ø 80 mm Mono version with one SPF pump with Comfort control unit including backflow preventer closure valve on pressure pipe side Mono versions 0 V Duo versions 0 V 0 V 00S 00S 000S 00S 00S 00S 000S 00S 00S 00S 000S 00S Ø 0 Duo version with two SPF pumps with Comfort control unit including backflow preventer and closure valve on pressure pipe side Ø 9 Welded PE pipe is to be used for the pressure pipe Approval pending See below for details of system chamber required Underground installation SmartSelect simply makes planning easier calculation tool for lifting stations at smartselect.kessel.com To be ordered separately: System chambers for installation in the ground (For order items see page ) for installation in a concrete slab (For order items see page ) Approval Z.7 Depth of wastewater pipe according plan 0 mm D Installation depth of systems chamber (D D) Height engineering systems base from base of inlet to top Catalogue.
40 Pumping stations for wastewater with or without sewage Underground installation outside buildings Professional advantages Pumping station Engineering systems chamber Pressure pipe Aqualift F XL disposes of large quantities of wastewater and is thus suitable not only for the classical application case of residential buildings, but also for commercial and industrial applications. The pumping station is available as a Mono or Duo station for wastewater with or without sewage. The tank volume is litres, the maximum pumping volume is approx. 0 litres. Aqualift F XL is equipped with pneumatic level measurement and an alarm sensor. The pumping station is suitable for installation in the ground or in concrete floors. The engineering chamber is suitable for installation in groundwater up to 000 mm. It is made up of modular chamber rings which are available in heights of 0 mm and 00 mm. Control units with selfdiagnosis system SDS for monitoring pump and battery buffering with monthly selftest. Comfort version with multiline display for operating state and maintenance instruction as well as userfriendly menu guidance in six languages. Pneumatic level measurement and an alarm sensor for double safety With inlet x elbow Ø 0 additional prescored areas Ø 0 x Ø % airtight screwed cleaning opening Tank floor resistant to groundwater depths up to 000 mm Fitting with integrated backwater preventer and aeration device for simple bleeding of the pressure pipe Closure valve with safety hoop to prevent unintentional closing Pumps (Mono/Duo) in different capacity classes High pumping volume approx. 0 litres Pump type: SPF 00S 0 % SPF 00S for continuous duty (e.g. rainwater) Pumping capacity: max. 8 m³/h Pumping height: max. 7 m SPF 000S 0 % SPF 000S for continuous duty (e.g. rainwater) Pumping capacity: max. 7 m³/h Pumping height: max. m A [m] 0 SPF 00S 0 % SPF 00S for continuous duty (e.g. rainwater) Pumping capacity: max. 0 m³/h Pumping height: max. 8 m SPF 00S 0 % SPF 00S for continuous duty (e.g. rainwater) Pumping capacity: max. m³/h Pumping height: max. 0 m 0 SPF 00 SPF 00 SPF 00 SPF Q [m /h] Catalogue.
41 Pumping stations for wastewater with or without sewage Engineering systems chamber Ø 000 mm for outdoor underground installation Products Illustration and dimensioned drawing Installation depth mm Installation depth D Ø 00 Engineering systems chamber for combination with Aqualift F XL systems base for outdoor underground installation made of polyethylene with access opening Ø 00 mm Upper section with cover, round made of cast iron, class A/B made of cast iron, class D with access opening Ø 800 mm Upper section with cover, round made of stainless steel, class K Upper sections for access openings Ø 800 mm with class B / D covers and other installation depths on request According to EN 98 Part Approval Z.7 D : 0 79 D : 80 9 D : D 7: D 8: 0 79 D 9: 80 9 D 0: D : D : 0 79 D : 80 9 D : D 7: D 8: 0 79 D 9: 80 9 D 0: D : D : 7 D : 87 D : 87 D : 7 D : 7 D : 87 D 7: 87 D 8: 7 D 9: 7 D 0: 87 D : Installation depth D Ø 800 Engineering systems chamber for combination with Aqualift F XL systems base for outdoor underground installation made of polyethylene with access opening Ø 800 mm Upper section with cover, square made of stainless steel, class A/L, nontileable antislip made of stainless steel, class A/L, tileable Covers resistant to surface water Handles groundwater depth up to 000 mm Delivered as individual elements Removable access aid art. no. 80 on request D : 9 D : 89 D : 89 D : 9 D : 9 D : 89 D 7: 89 D 8: 9 D 9: 9 D 0: 89 D : 89 D : 0 D : 90 D : 9 0 D : 0 D : 0 D : 90 D 7: 9 0 D 8: 0 D 9: 0 D 0: 90 D : Upper sections for access openings Ø 800 mm with class B / D covers and other installation depths on request According to EN 98 Part Approval Z.7 Catalogue.
42 Pumping stations for wastewater with or without sewage Engineering systems chamber Ø 000 mm for installation in a concrete slab Products Illustration and dimensioned drawing Installation depth mm Engineering systems base for combination with the Aqualift F XL systems base for installation in the concrete slab made of polyethylene Waterproof concrete version with flange and counter flange with access opening Ø 800 mm Upper section with cover, square made of stainless steel, class A/L Tileable cover D : D : D : 8 77 D : 78 7 D : D : 8 D : 8 D : D : D : Ø 800 Upper section with cover, square made of stainless steel, class A/L, slipresistant Nontileable cover Installation depth D Upper sections with covers class B / D on request Handles groundwater depth up to 000 mm Delivered as individual elements Mobile access aid Art. No. 80 on request According to EN 98 Part Approval Z.7 Engineering systems chamber Ø 000 mm Illustration Extension section for engineering systems chamber, without gasket and connecting wedges, H = 00 mm Access aid, pieces needed Outer diameter Ø (mm) Accessories Extension section for engineering systems chamber, without gasket and connecting wedges, H = 0 mm Access aid, piece needed Set of connecting wedges 0 pieces Profiled gasket 80 Catalogue.
43 Pumping stations for wastewater with or without sewage Aqualift F Ø 00 Products Illustration and dimensioned drawing Installation depths Class B Class D Pumping station Aqualift F with macerating / cutting pumps in inspection chamber system Ø 00 in PELLD Single station/twin station for wastewater with or without sewage For underground installation D: D: D: D: D: D: B B B 87 7 B 87 7 B 87 7 B D D D 87 7 D 87 7 D 87 7 D SPZ 000 float switch controlled, removeable pump, plug in ready (0 V / 0Hz) SPZ 000 pressure sensor controlled, removable pump, IP SDS control unit (0 V / 0Hz) D: D: D: 8 7 B 8 7 B 8 7 B 8 7 D 8 7 D 8 7 D SPZ 000 pressure sensor controlled, removable twin pumps, IP SDS control unit (0 V / 0Hz) 700 / 00 / Ø80 Installation depths D Installation depths (D): D D D mm mm mm Cover plate class A/B (Version B) Cover plate class D (Version D) Resistant to aggressive media, upper section made of polymer, vertically adjustable, cover class A/B, D in cast iron according to EN. Groundwater resistant. Inlet Ø 0, connection for pipe gasket for Ø 0 according to EN 0 and EN each for ventilation or conduit pipe. Note: Consider frost free depth of pressure pipe. Pressure pipe Ø 0 mm outside diameter for PVC glue connection, with integrated nonreturn flap. Current: 0 V ~ 0 Hz. Power cable length: 0 m. For installations without explosion proof requirements Handles groundwater depths up to 000 mm EN 00 (max WC connections) Catalogue.
44 Pumping stations for wastewater with or without sewage Installation example pumping station Aqualift F Ø 00 Professional advantages Pumping station Pump The pumping station Aqualift F Ø 00 can be used for the draining of wastewater with or without sewage below the backwater level, as backwater protection for separator systems and for draining basement apartments or driveways. The wastewater flows with natural gradient to the collecting chamber and is pumped by the integrated pumps SPZ 000 via the backwater loop to a higherlevel sewage channel. The pressure pipe should always be laid frostfree. A control unit takes over the fully automatic pump control from within the building. Float switches or a pressure sensor are available as level sensors. Pressure pipe Pressure sensor Inexpensive complete system For draining wastewater with or without sewage For backwater protection connected to a separator Simple to assemble with lightweight inspection chamber components and easy connection technique. Quick to mount with a high level of prefabrication and easy connection using fixed couplings for inlet and pressure pipe and bores with lip gaskets for ventilation and cable piping. Variable upper section inclinable and height adjustable from 00 to 00 mm. Toolfree pump removal The onehand snap closure feature means that no tools are required to remove the pump for cleaning and maintenance. H [m] SPZ Q [m /h] Type Current type Voltage Current Power P/P RPM Motor protection Operating mode SPZ 000 Alternating current 0 V.9 A 080 W / 0 W 800 min integrated S 0 % Catalogue. 7
45 Pumping stations for wastewater with or without sewage Aqualift F Ø 800 / 000 Illustration and dimensioned drawing Pumping station Aqualift F (AP 0) in Komfort inspection chamber system Ø 800 / 000 in PEHD Single station/twin station for wastewater with or without sewage For underground installation AP 0 with removable, float switch controlled pump, plug in ready (0 V power connection) AP 0 Tronic with removable, float switch controlled pump, floats (OFF, ON, ALARM) with control unit (IP ), operating voltage 0 or DC at 0 Hz, with potentialfree contact AP 0 Duo with twin removable, float switch controlled pump, floats (OFF, ON, ON, ALARM), with control unit (IP, operating voltage 0 or DC at 0 Hz, with potentialfree contact Installation depths Komfort inspection chamber system Ø 800 D: D: D: D: D: D: D: D: D: 0 V 0 V 0 V 0 V 0 V 0 V 800HA0B 800HA0B 800HA0B 800HAB 800HAB 800HAB 800HAB 800HAB 800HAB Products Komfort inspection chamber system Ø 000 D: D: D: 0 V 0 V 0 V 000HAB 000HAD 000HAB 000HAD 000HAB 000HAD D: D: D: Voltage Class B 000HAB 000HAB 000HAB Class D 800HA0D 800HA0D 800HA0D 800HAD 800HAD 800HAD 800HAD 800HAD 800HAD 000HAD 000HAD 000HAD Cover plate class A/B (Version B) Cover plate class D (Version D) Installation depths (D) Ø 800 D mm D mm D mm Installation depths (D) Ø 000 D 0 0 mm D 0 0 mm D 0 0 mm Inspection chamber system KESSEL Ø 800 / 000 in PEHD watertight, resistant to aggressive media, upper section made of polymer, continuous height and level adjustment, cover class A/B, D in cast iron according to EN. Groundwater resistant. Inlet Ø 0, connection for pipe seal for Ø 0 according to EN 0 for ventilation pipes and cable piping respectively, pumping volume approx. 0 l Pressure pipe ready mounted with backwater flap, closure valve and float switch for level control with cable length 0 m, pressure pipe connection PEHD Ø mm and Ø 90 mm. Submersible pump AP 0 Single or twin submersible pump(s) 0.7 kw (without explosion protection), with nonchokable impeller to pump wastewater with or without sewage, submersible (IP 8), electrical cable length 0 m. For installations without explosion proof requirements Handles groundwater depths up to 00 mm 8 Catalogue.
46 Pumping stations for wastewater with or without sewage Installation example pumping station Aqualift F Ø 800 / 000 Professional advantages Pumping station Pump H [m] Pressure pipe Float switch The pumping station Aqualift F can be used for the draining of wastewater with or without sewage below the backwater level, as backwater protection for separator systems and for draining basement apartments or driveways. The wastewater flows with natural gradient to the Komfort chamber Ø 800 or 000 and is pumped by the integrated pumps AP 0 to a higherlevel sewage channel. The pressure pipe should always be laid frostfree. A control unit takes over the fully automatic pump control from within the building. Float switches are used as level and alarm sensors. Inexpensive complete system For draining wastewater with or without sewage. For backwater protection connected to a separator For draining basements, yards or driveways Variable upper section inclinable and height adjustable from 00 to 00 mm Simple to assemble with lightweight inspection chamber components and easy connection technique. Longterm reliability with an absolute watertight inspection chamber system which is resistant to sedimentary deposits and aggressive media as well as root infiltration. Fully automated operation with an electrical control unit with manual, off and automatic mode, optical and audible warning and alarm notification, detailed operation and warning display, integrated pump rotation check, antiblocking function, variable pump on and pump off settings. More output System with stronger pumps available on request 0 8 AP Q [m /h] Type Mono, Tronic, Duo Tronic, Duo Power 0.7 kw 0.7 kw Input power. kw. kw Current A.8 A Voltage 0 V at 0 Hz at 0 Hz Cable length 0 m 0 m Protection IP 8; without explosion protection IP 8; without explosion protection Catalogue. 9
47 Pumping stations for wastewater with or without sewage Aqualift F Ø 000 Products Illustration and dimensioned drawing Pumping capacity Pressure pipe* Class B Class D Ventilation / cable piping 0 Installation depths (D): D D D D D D D 7 Installation depths D 0 0 mm 0 0 mm 0 0 mm 0 0 mm 0 0 mm 0 0 mm 0 0 mm Pumping station Aqualift F in Komfort inspection chamber system Ø 000 in PEHD Single station/twin station for wastewater with or without sewage For underground installation Single station Twin station Cover plate class A/B (Version B) Cover plate class D (Version D) Including access steps, watertight, resistant to aggressive media, upper section made of polymer, continuous height and level adjustment, cover class A/B, D in cast iron according to EN, inlet Ø 0, cable conduit connection Ø 0 according to EN 0 and EN for ventilation pipes and cable piping respectively. Installation depth from. to m (see table), Pumping volume approx. 80 liters. Pressure pipe ready mounted with backwater flap, closure valve. Single station with three float switches, twin station with four float switches for level control with cable length 0 m, pressure pipe connection PEHD Ø and Ø 90. Submersible pump TPF. KE / TPF.9 KE explosionproof, with macerating blades for pumping wastewater with or without sewage, submersible (IP 8), electrical cable length 0 m. Electric control unit for fully automated pump operation, control unit is splash proof (IP ), for wall mounting in dry, frostfree areas, PTB certification for installation in explosion risk areas, voltage at 0 Hz. With potentialfree contact. Handles groundwater depths up to 00 mm (greater groundwater resistance on request) Explosive proof Accessories see page 0 *) Ø 90 by sawing off. kw. kw. kw. kw. kw. kw. kw.9 kw.9 kw.9 kw.9 kw.9 kw.9 kw.9 kw. kw. kw. kw. kw. kw. kw. kw.9 kw.9 kw.9 kw.9 kw.9 kw.9 kw.9 kw D: /90 D: /90 D: /90 D: /90 D: /90 D: /90 D7: /90 D: /90 D: /90 D: /90 D: /90 D: /90 D: /90 D7: /90 D: /90 D: /90 D: /90 D: /90 D: /90 D: /90 D7: /90 D: /90 D: /90 D: /90 D: /90 D: /90 D: /90 D7: / B 8 0 B 8 0 B 8 0 B 8 0 B 8 0 B 8 70 B 8 70 B 8 70 B 8 70 B 8 70 B 8 70 B 8 70 B B 8 0 B 8 0 B 8 0 B 8 0 B 8 0 B 8 0 B 8 70 B 8 70 B 8 70 B 8 70 B 8 70 B 8 70 B 8 70 B B 8 0 D 8 0 D 8 0 D 8 0 D 8 0 D 8 0 D 8 70 D 8 70 D 8 70 D 8 70 D 8 70 D 8 70 D 8 70 D D 8 0 D 8 0 D 8 0 D 8 0 D 8 0 D 8 0 D 8 70 D 8 70 D 8 70 D 8 70 D 8 70 D 8 70 D 8 70 D D Optional olt Comfort control unit Art. # D EN 00 0 Catalogue.
48 Pumping stations for wastewater with or without sewage Installation example pumping station Aqualift F Ø 000 Professional advantages Pumping station Pump Domestic wastewater flows with natural gradient to the pumping station and is pumped by the integrated TPF macerator pump over long distances (pressure pipe) into the sewer. The pressure pipe should always be laid frostfree. A control unit takes over the fully automatic pump control from within the building. Float switches are used as level sensors. The system complies with the ATEX product directive and is suitable for installation in potentially explosive atmospheres. H [m] 0 8 Qmin for Ø mm* Qmin for Ø 90 mm* 0 * according to EN 0 Pump type Power (P) Input power (P) Amperage Fuses Voltage Cable length Protection TPF. kw TPF. KE. kw.7 kw. A x A surgeproof at 0 HZ 0 m Length, 7 x. mm IP 8 Exprotection Q [m /h] H [m] TPF.9 kw Qmin for Ø mm* Pump type Power (P) Input power (P) Amperage Fuses Voltage Cable length Protection Pressure pipe Float switches Qmin for Ø 90 mm* 0 0 TPF.9 KE.9 kw. kw. A x A surgeproof at 0 HZ 0 m Length, 7 x. mm IP 8 Exprotection Q [m /h] Variable upper section inclinable and height adjustable from 00 to 00 mm Comfort control unit (optional) with mains power ON / OFF switch and multilingual digital display (EN, DE, FR, IT, PL, NL) showing current operational status, settings and logbook Simple to assemble with lightweight inspection chamber components and easy connection technique. Quick to mount with a high level of prefabrication (bottom part of inspection chamber with pressure pipe) and easy connection using fixed couplings for inlet and pressure pipe and bores with lip gaskets for ventilation and cable piping. Longterm reliability with an absolute watertight inspection chamber system which is resistant to sedimentary deposits and aggressive media as well as root infiltration. Fully automated operation with an electrical control unit with manual, off and automatic mode, optical and audible warning and alarm notification, detailed operation and warning display, integrated pump rotation check, antiblocking function, variable pump on and pump off settings. Systems with macerator permit the realisation of smaller dimensioning of the pressure pipes and longer distances to the sewage system. High pumping volume thanks to the pump chamber. Additional reserve volume if the system should fail e.g. in the event of a power cut. Further inlets up to Ø 0 can be attached on site, Ø 00 or larger in the factory. Suitable for installation in explosion risk areas Catalogue.
49 Pumping stations for wastewater without sewage Aqualift S Ø 00 Products Illustration and dimensioned drawing Pump KTP / GTF Class B Class D 700 / 00 / Ø80 Installation depths D Installation depths (D): D D D mm mm mm Pumping station Aqualift S in inspection chamber system Ø 00 in PELLD Single station/twin station for wastewater without sewage For underground installation KTP 00/GTF 000 float switch controlled removable pump for conductive or nonconductive fluids. Input power (P): 0.8 /.8 kw. KTP 00/GTF 000 Tronic with removable, pressure sensor controlled pump for conductive or nonconductive fluids, with SDS control unit. Input power (P): 0.8 /.8 kw. KTP 00/GTF 000 Duo with removable, pressure sensor controlled twin pumps for conductive or nonconductive fluids, with SDS control unit. Input power (P): x 0.8 /.8 kw. Cover plate class A/B (Version B) Cover plate class D (Version D) Inspection chamber system Ø 00 in PELLD, resistant to aggressive media, upper section made of polymer, vertically adjustable, cover class A/B, D in cast iron according to EN. Groundwater resistant. Inlet Ø 0 (KTP 00), Ø 0 (GTF 000), connection for pipe seal for Ø 0 according to EN 0 and EN each for ventilation or cable pipe, Note: Consider frost free depth of pressure pipe Pressure pipe Ø 0 mm outside diameter for PVC glue connection, with integrated nonreturn flap, 0 mm max solid size, Current: 0 V ~ 0 Hz. Power cable length: 0 m. D: KTP 00 D: KTP 00 D: KTP 00 D: GTF 000 D: GTF 000 D: GTF 000 D: KTP 00 D: KTP 00 D: KTP 00 D: GTF 000 D: GTF 000 D: GTF 000 D: KTP 00 D: KTP 00 D: KTP 00 D: GTF 000 D: GTF 000 D: GTF B 8 80 B 8 80 B B B B 8 8 B 8 8 B 8 8 B 87 8 B 87 8 B 87 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 80 D 8 80 D 8 80 D D D D 8 8 D 8 8 D 8 8 D 87 8 D 87 8 D 87 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D Handles groundwater depths up to 000 mm EN 00 Catalogue.
50 Pumping stations for wastewater without sewage Installation example pumping station Aqualift S Ø 00 Professional advantages Pumping station Pump The pumping station Aqualift S Ø 00 can be used for the draining of wastewater without sewage below the backwater level, as backwater protection for separator systems and for draining basement apartments or driveways. The wastewater flows with natural gradient to the collecting chamber and is pumped by the integrated pumps KTP 00 / GTF 000 to a higherlevel sewage channel. The pressure pipe should always be laid frostfree. A control unit takes over the fully automatic pump control from within the building. Float switches or a pressure sensor are available as level sensors. Pressure pipe Pressure sensor Inexpensive complete system For draining wastewater without sewage For backwater protection connected after a grease separator Simple to assemble with lightweight inspection chamber components and easy connection technique. Quick to mount with a high level of prefabrication and easy connection using fixed couplings for inlet and pressure pipe and bores with lip gaskets for ventilation and cable piping. Variable upper section inclinable and height adjustable from 00 to 00 mm. Toolfree pump removal The onehand snap closure feature means that no tools are required to remove the pump for cleaning and maintenance. (see Minilift ) H [m] 0 8 KTP 00 GTF Q [m /h] Current type Voltage Current Power P/P RPM Motor protection Operating mode KTP 00 GTF 000 Alternating current Alternating current 0 V 0 V. A.9 A 80 W / 0 W 80 W / 70 W 800 min 800 min integrated integrated S S 0 % Catalogue.
51 Pumping stations for wastewater without sewage Aqualift S Ø 000 Products Illustration and dimensioned drawing Pump KTP / GTF Class B Class D Pumping station Aqualift S in Komfort inspection chamber system Ø 000 in PEHD Single station/twin station for wastewater without sewage / rainwater For underground installation KTP 00/GTF 000 float switch controlled removable pump for conductive or nonconductive fluids. Input power (P): 0.8 /.8 kw. KTP 00/GTF 000 Tronic with removable, pressure sensor controlled pump for conductive or nonconductive fluids, with SDS control unit. Input power (P): 0.8 /.8 kw. KTP 00/GTF 000 Duo with removable, pressure sensor controlled twin pumps for conductive or nonconductive fluids, with SDS control unit. Input power (P): x 0.8 /.8 kw. Cover plate class A/B (Version B) Cover plate class D (Version D) D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D7: KTP 00 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D7: GTF 000 D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D7: KTP 00 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D7: GTF 000 D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D: KTP 00 D7: KTP 00 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D: GTF 000 D7: GTF B 8 80 B 8 80 B 8 80 B 8 80 B 8 80 B B B B B B B B B 8 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 87 B 87 8 B 87 8 B 87 8 B 87 8 B 87 8 B 87 8 B B 8 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 87 B 8 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 8 B 8 87 B 8 80 D 8 80 D 8 80 D 8 80 D 8 80 D 8 80 D D D D D D D D D 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 87 D 87 8 D 87 8 D 87 8 D 87 8 D 87 8 D 87 8 D D 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 87 D 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 8 D 8 87 D 00 D D D D D D D 7 Installation depth D 0 Installation depths (D): 0 0 mm 0 0 mm 0 0 mm 0 0 mm 0 0 mm 0 0 mm 0 0 mm Inspection chamber system Ø 000 in PEHD, including access steps, watertight, resistant to aggressive media, upper section made of polymer, continuous height and level adjustment, cover class A/B, D in cast iron according to EN. Inlet Ø 0, connection drilling with gasket for Ø 0 according to EN 0 and EN for ventilation pipes and cable piping respectively, Installation depth from. to m (see table), Pumping volume approx. 80 liters. Pressure pipe outlet connection: / inch exterior thread, pressure pipe Ø 0 mm outside diameter for PVC glue connection, with integrated nonreturn flap, 0 mm max solid size. Current: 0 V ~ 0 Hz. Power cable length: 0 m. Handles groundwater depths up to 00 mm (greater groundwater resistance on request) D EN 00 Catalogue.
52 Pumping stations for wastewater without sewage Installation example pumping station Aqualift S Ø 000 Professional advantages Gutter drain Pumping station Pump Float switch Variable upper section inclinable and height adjustable from 00 to 00 mm Simple to assemble with lightweight inspection chamber components and easy connection technique. Quick to mount with a high level of prefabrication (bottom part of inspection chamber with pressure pipe) and easy connection using fixed couplings for inlet and pressure pipe and bores with lip gaskets for ventilation and cable piping. Longterm reliability with an absolute watertight inspection chamber system which is resistant to sedimentary deposits and aggressive media as well as root infiltration. Ideal for direct rainwater disposal to the sewage system. The wastewater flows into the gutter drain and then under natural gravity to the Aqualift S pumping station and is pumped by the integrated pumps KTP 00 / GTF 000 into the sewage system. A float switch is used as a level sensor. H [m] 0 8 KTP 00 GTF Q [m /h] Current type Voltage Current Power P/P RPM Motor protection Operating mode KTP 00 GTF 000 Alternating current Alternating current 0 V 0 V. A.9 A 80 W / 0 W 80 W / 70 W 800 min 800 min integrated integrated S S 0 % Catalogue.
53 Submersible pumps for wastewater without sewage GTF 000 Products Illustration and dimensioned drawing Pressure connection 9 Submersible pump GTF 000 for wastewater without sewage with/without float switch Connection to pressure pipe / inch. Outlet side / vertical, without macerator, cable length 0 m / inch / inch without float switch with float switch Voltage: 0 V ~ 0 Hz Input power (P): 080 W Max. pumping height: 0 m Max. pumping capacity:, m /h Max. submersible depth: 0 m Max. particle size: 0 mm Pressure connection: / inch side / vertical GTF 000 H [m] 0 LGA Typetested and monitored guaranteed with tested quality Q [m /h] Current type Voltage Current Power P/P RPM Motor protection Operating mode Alternating current 0 V.9 A 080 W / 0 W 800 min integrated S 0 % KTP 00 Products Illustration and dimensioned drawing Pressure connection Submersible pump KTP 00 / KTP 00 TITAN for wastewater without sewage with/without float switch Connection to pressure pipe / inch. Outlet side / vertical, cable length 0 m without float switch with float switch Voltage: 0 V ~ 0 Hz Input power (P): 80 W Max. pumping height: 8 m Max. pumping capacity: 8 m /h Max. submersible depth: 0 m Max. particle size: 0 mm Pressure connection: / inch side / vertical KTP 00 / inch / inch KTP 00 TITAN / inch / inch Special model with titanium shaft Suitable for mechanical and chemical polluted media. Also resistant to chloridecontaining media. Not to be used for nitro and trichloroethylene [m] 7 7Q [m /h] Current type Voltage Current Power P/P RPM Motor protection Operating mode KTP 00 Alternating current 0 V. A 80 W / 0 W 800 min integrated S LGA Typetested and monitored guaranteed with tested quality Catalogue.
54 Submersible pumps for wastewater with or without sewage KTP 00 Products Illustration and dimensioned drawing Pressure connection Submersible pump KTP 00 for wastewater without sewage with/without float switch With backwater flap, pivotable connection, cable length 0 m inch inch without float switch with float switch Input power (P): 80 W. Voltage: 0 V ~ 0 Hz. Max. pumping height: m. Max. pumping capacity: 8 m /h. Max. submersible depth: 0 m. max. particle size: 0 mm. Pressure connection: inch side / vertical Removable input basket reduction in the water level to 8 mm possible. H [m] LGA Typetested and monitored guaranteed with tested quality Q [m /h] Current type Voltage Current Power P/P RPM Motor protection Plug KTP 00 Alternating current 0 V.9 A 80 W / W 800 min integrated Schuko SPZ 000 Products Illustration and dimensioned drawing Pressure connection Submersible pump SPZ 000 for wastewater containing raw sewage with/without float switch with macerator. Connection to pressure pipe / inch. Outlet side / vertical, cable length 0 m / inch / inch without float switch with float switch Voltage: 0 V ~ 0 Hz Input power (P): 080 W Max. pumping height: 0 m Max. pumping capacity: m /h Max. submersible depth: 0 m Pressure connection: / inch side / vertical SPZ 000 H [m] Q [m /h] Current type Voltage Current Power P/P RPM Motor protection Operating mode Alternating current 0 V.9 A 080 W / 0 W 800 min integrated S 0 % Catalogue. 7
55 KESSELProduct information Warning and control units Warning and control units for versatile uses 0 Volt olt Comfort control units with multiline digital display INTEGRATED SELFDIAGNOSISSYSTEM With integrated SelfDiagnosisSystem and battery buffering continually monitors all electronic functions. TeleControl TELEMETRIC SYSTEM For connection to KESSEL Comfort control units 0 Volt and 00 Volt. Relaying of full text messages to up to three mobile phones. Without SIM card. ATEX VERSION olt control unit available in ATEX versions suitable for installation in potentially explosive atmospheres. The warning and control units can be used for a wide range of purposes e.g. as warning devices in household and industrial systems as well as for connection to a remote signal sensor. The warning and control units with potentialfree contact can be connected to the building management system (BMS). The electronic sensors react to all conductive fluids and the optical sensors to all conductive and nonconductive fluids. POTENTIALFREE CONTACT BMS (Building Management System) connection standard with all olt systems (optional with 0 Volt systems). PROBES Connection possibilities for numerous probes for level measurement, float switches, conductance probes (0 V only), plungers, optical probe (0 V only), level probe (on clamping strip). OPERATIONAL PARAMETERS Operational parameters can easily be custom set by operator Control unit also for use with pumps from other manufacturers. 8 Catalogue.
56 Readout of the electronic operating log and simple parameter adjustments store readout data on USB flash drive load to PC and transmit by read in optimised data again MENU NAVIGATION Userfriendly menu navigation in six languages with multilingual display. ELECTRONIC LOGBOOK Electronic logbook function past history of pump operation is shown on digital control unit display. USBCONNECTION PORT Includes internal USB connection port for 0 Volt control units. For readout of electrical logbook and down / uploading of operational parameters. USB housing socket optional. READY FOR CONNECTION 0 Volt control unit ready for connection by coded connectors for pumps and pressure sensor no need for a qualified electrician for connection. Also suitable for thirdparty pumps Catalogue. 9
57 Warning and control units 0 V Comfort control unit Products Illustration 0 V Comfort control units Mono Duo Mono/Duo control unit extremely versatile sensor system for measuring the level of wastewater with and without sewage. Including plunger for pneumatic level measurement. For greasy wastewater or wastewater at higher temperature only in connection with a small compressor for bubble formation (Art. # 8 08) with pressure sensor*/without extra alarm probe 0 m pressure hose (can be extended to m) 8 7 D 8 7 D with pressure sensor*/conductance probe with separate conductance probe for alarm level measurement 0 m pressure hose (can be extended to m) m cable (cannot be extended) 8 7 DL 8 7 DL with pressure sensor*/float switch with separate float switch for alarm level measurement 0 m pressure hose (can be extended to m, up to 0 m on request) 0 m float switch cable (can be extended to 0 m) 8 7 DS 8 7 DS with pressure sensor*/optical probe with separate optical probe for alarm level measurement and failure detection of the optical probe via the control unit 0 m pressure hose (can be extended to, up to 0 m on request) m cable for optical probe (can be extended to 0 m) 8 7 DO 8 7 DO Mono/Duo control unit sensor system for level measurement for wastewater without sewage. With float switches to measure ON, ON (only 8 7S) and OFF levels. with float switch/without extra alarm probe 0 m float switch cable (can be extended to 0 m) 8 7 S 8 7 S with float switch*/float switch with separate float switch for alarm level measurement 0 m float switch cable (can be extended to 0 m) 8 7 SX 8 7 SX *air compressor available for pressure switches with over 0 m cable 0 Catalogue.
58 Warning and control units 0 V Comfort control unit Products Illustration 0 V Comfort control units Mono/Duo control unit Mono Duo Extremely versatile sensor system for measuring the level of wastewater with and without sewage. Including level probe for pneumatic level measurement and failure detection of the level probe via the control unit. For greasy wastewater or wastewater at higher temperature, the use of a small compressor is not necessary with level probe/without extra alarm probe 0 m level probe cable (can be extended to 0 m) with level probe/float switch with float switch for alarm level measurement 0 m level probe cable (can be extended to 0 m) 0 m float switch cable (can be extended to 0 m) P 8 7 P 8 7 PS 8 7 PS Mono/Duo control unit sensor system for level measurement for wastewater without sewage. Including alarm level measurement. Not suitable for rainwater or nondiluted condensate. Including conductance probes for the measuring of ON, ON (8 7LLF/87LLV only), OFF and ALARM level. Switching points cannot be adjusted freely. 9 0 Mono control unit 9 with conductance probe/conductance probe Level ON/OFF fixed, alarm level can be adjusted m cable for conductance probe Duo control units LL 0 with conductance probe/conductance probe ON fixed/on variable/alarm with fixed distance to ON m cable for conductance probe LLF with conductance probe/conductance probe ON variable/on fixed/alarm with fixed distance to ON m cable for conductance probe) 8 7 LLV Level probe level probe cable 0 m Float switch float switch cable 0 m float switch cable 0 m Comfort control unit Products Illustration Comfort control unit Mono Duo suitable for max. switching current from to..0 A Mono.0. A Mono. 0.0 A Mono x..0 A Duo x.0. A Duo x. 0.0 A Duo..0 A ATEX version, Mono.0. A ATEX version, Mono x..0 A ATEX version, Duo x.0. A ATEX version, Duo Catalogue.
59 Warning and control units Warning units / 0 V Comfort control units / Comfort control units Accessories Illustration TeleControl telemetric system for connection to KESSEL Comfort control units 0 Volt and olt. Relaying of full text messages to up to three mobile phones. Without SIM card TeleControl antenna booster for TeleControl telemetric system incl.. m cable to improve reception. With magnetic base Antenna booster extension cable cable length. m Alarm unit with electrode probe with optical probe for article numbers: Connector set for connection to pump/probe cables for connection to the coded connectors from 8 7 / Audible alarm cable length 0 m suitable for all warning and control units 0 Potentialfree contact suitable for all warning and control units 8007 USB housing socket for routing the USB connection to the outside of the housing suitable for 0 Volt Comfort control units Mono/Duo 8 78 Cable extension set (for motor) 0 m cable length A maximum of two cable extension sets can be connected Cable extension set (for probe) 0 m cable length A maximum of two cable extension sets can be connected Compressor set for use in combination with lifting stations and pumping stations with pressure control: prevents soiling, compensates leaks, avoids the formation of condensate in the pressure hose, makes operation of systems possible with pressure hose lengths > 0 m, including Tpiece connection, including 0 m pressure hose 8 08 Catalogue.
60 Individual Solutions Pumping station Aqualift F Duo (TPF. / TPF.9) for freestanding installation (Illustration shows Art. # 000HA F and Art. # TPF KE DUO) Ø Komfort chamber system Ø 000 Quick release odor tight access cover Inlet Ø 0 mm Pressure outlet Ø= /90 mm Connection seal Ø 0 (cable conduit and ventilation connections) Control unit Duo, level control 7 Twin pumping system with pump type TPF. KE or TPF.9 KE Tender text: Pump chamber Ø 000 with wastewater lifting station Aqualift F Duo with pump type TPF KE for freestanding setup in frostfree rooms, made of polyethylene PEHD, waterproof, resistant against aggressive wastewater. Cover hood made of plastic, with quick action closure, sealed odourtight. Inlet muff made of PEHD, connection for Ø 0 according to EN 0 and EN one each for ventilation and cable conduit. Chamber system: Komfort Ø 000 Design height: 0 mm Diameter (Ø): mm Inlet: up to Ø 00 Type of cover: Cover hood, odourtight Pressure connection: Ø /90 mm Pumping medium: wastewater with and without sewage Pump control: float control Catalogue.
61 Individual Solutions Pumping station Aqualift F Duo, with overflow channel and backwater valve FKA (Illustration shows Art. # 8 0B and chamber system Komfort Ø 000 with Staufix FKA) T Tmin= 00 Tmax= 00 0 T 080 during bei Rückstau backwater Pumping station Aqualift F Duo Chamber system Komfort Ø 000 Channel passage with overflow opening Backwater valve Staufix FKA for wastewater with/without sewage Outlet for pressure pipe Loop via backwater level Catalogue.
62 Individual Solutions Pumping station Aqualift F Duo, with overflow channel and backwater valve FKA Function: Standard operation: In standard operation, the connected drainage fixtures can drain by means of natural gravity through the open channel to the sewer. Backwater protection: If there is any backwater from the sewer, the sensor system in the backwater valve Staufix FKA detects backwater in the drain pipe and closes the motordriven flap, thus securing the building. Disposal during the backwater phase Any wastewater from the building which occurs during this phase pours through the overflow opening into the pumping station. When the respective switching level is reached, the wastewater is disposed of by the pumping station into the sewer via the pressure pipe against the pressure of the backwater. Standard operation: After backwater the backwater valve Staufix FKA automatically reopens, the connected drainage fixtures can be drained through the open channel again. Tender text: Pumping station Aqualift F (Duo system) for wastewater with or without sewage, for underground installation, made of polyethylene PEHD with access steps, watertight, resistant against aggressive wastewater. Polymer upper section for continuous height and level compensation, cover plate made of cast iron according to EN. Connection hole with sealing gasket Ø 0 in accordance with EN 0 and EN for ventilation and cable conduits respectively, pump volume approx. 00 l. Pressure pipe preassembled with backwater flap, closure valve and float switches for level control. Two submersible pumps in explosionprotected version, with cutting unit for pumping wastewater with and without sewage, floodproof. Electric control unit for fully automatic pump control, splashwaterproof, for wall mounting in dry, frostfree areas of the building, PTB approval for potentially explosive areas (ATEX), with potentialfree contact. Chamber system: Komfort Ø 000 Standard: EN 7 Installation depth: mm Inlet depth: mm Inlet: passage channel Ø with overflow opening Pressure socket: Ø mm / Ø 90 mm Type of cover: unscrewed Load class: B (. t) Pump type: (optional) Pumping station: Aqualift F (Duo system) Pump type: TPF. KE Standard: EN 00 Feed rate: max. m³/h Pumping height: max. 7. m Rated power: x. kw Input power: x.7 kw Operating voltage: DC Rated frequency: 0 Hz Rated current:. A Fuse protection: x A slowblow Protective rating (pumps): IP 8 EXprotection Protective rating (control unit): IP Cable length: 0 m (7 x. mm ) Pumping station: Aqualift F (Duo system) Pump type: TPF.9 KE Standard : EN 00 Feed rate: max. 0. m³/h Pumping height: max..0 m Rated power: x.9 kw Input power: x. kw Operating voltage: DC Rated frequency: 0 Hz Rated current:. A Fuse protection: x A slowblow Protective rating (pumps): IP 8 EXprotection Protective rating (control unit): IP Cable length: 0 m (7 x. mm ) Catalogue.
63 Individual Solutions Lifting station Aqualift F XL 900 liters Lifting station Aqualift F XL 900 L for free standing installation Tank volume: 900 liters Pump volume: 00 liters Twin station with two SPF pumps for wastewater with or without sewage for freestanding installation in frostfree rooms Consisting of: Two Polyethylene storage chambers, with air pressure level detector, cleanout opening. Spigots for vertical inlet Ø 0 mm/0 mm, ventilation Ø 7 mm and for manual diaphragm pump Ø mm. Horizontal inlet Ø 0 mm to Ø 00 mm by sawing. Pressure sensor controlled twin wastewater pumps with nonchokable impeller to pump wastewater with or without sewage (open channel passage 0 mm). Pump is rated submersible (IP 8), power cable length 0 m. Operating mode: S: Continous duty S: 0 % power on duration Vertical/ horizontal outlet with integrated nonreturn valve, with/without closure valve (provided loose), with hose section or flange. Comfort control unit with mains power ON / OFF switch and multilingual digital display (EN, DE, FR, IT, PL, NL) showing current operational status, settings and logbook; control unit is splash proof (IP ), wall mounted, voltage 0 V or at 0 Hz.With potentialfree/bms contact (optional on 0 V models). Pumps for collection tank Illustration and dimensioned drawing Illustratin shows AQUALI000D 0 0 AQUALI000D Pump KTP / GTF Sensor Aqualift F Duo pumping system for installation in onsite collection tank Twin pump system for sewage free wastewater (rainwater or nonwc wastewater) For installation in existing collection tanks with: PEHD fixing mount for installation and mounting of pumping system Two removable GTF 000 / KTP 00, 0V/ 0Hz Pressure sensor level control for conductive and non conductive liquids With Aqualift Comfort 0 Volt duo control unit Pressure piping with nonreturn flap and closure lever Pressure connection: OD0 mm pressure pipe for PVC glue connection With Comfort control unit for wall mounting in dry, frost protected rooms, splashproof, fully automated pump level control with optical and audible alarm system, detailed operation and warning status in multiple line digital display. Optional forwarding of alarm and fault message via GSM interface GTF 000 GTF 000 KTP 00 KTP 00 H [m] 0 8 Pressure sensor Floater Pressure sensor Floater AQUALI000D* AQUALI000DS* AQUALI00D* AQUALI00DS* 8 0 Q [m /h] * Custom made product (delivery time on request) Catalogue.
3 Wastewater lifting stations
Wastewater lifting stations for wastewater containing raw sewage for free standing installation and for installation in a concrete floor Page 66 8 for underground installation Page 9 0 for wastewater without
More informationPOWER and INTELLIGENCE
POWER and INTELLIGENCE Lifting stations The new lifting station Aqualift F Compact - Sewage lifting station complete basement drainage installation in a slab/floor and free-standing installation Leading
More informationINSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease Separator G, D and D+S versions Certified under Euro-Norm EN 1825-1 For free standing installation in frost free areas KESSEL Grease separators G,
More informationKESSEL-Staufix FKA Backwater Valve
INSTALLATION AND USER S MANUAL NETZ SIGNAL RÜCKSTAU KLAPPE PRÜFEN KESSEL-Staufix FKA Backwater Valve Double flap backwater valve with motorized flap and manual closure lever Optical probe for backwater
More informationLifting Plants Product Overview
Wilo-DrainLift Con Duty chart (-pole, 5 Hz) 5 Wilo-DrainLift Con Lifting Plants Product Overview Wilo-DrainLift Lifting Plants Condensate lifting plants Removal of condensate, can be used in Condensing
More informationSekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS
Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS Wastewater is a demanding process, performance, day in day out. Xylem challenges, providing trusted
More informationKESSEL Grease separator M NG 2, 4, 7 and 10 For installation in frost free areas With manually automated disposal program
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease separator M NG 2, 4, 7 and 10 For installation in frost free areas With manually automated disposal program Version according to DIN 4040-1 or Version
More informationmini-compacta Type Series Booklet
Floodable Sewage Lifting Unit 60 Hz Type Series Booklet Legal information/copyright Type Series Booklet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced,
More informationTrusted Expertise in Domestic and Commercial Wastewater
Trusted Expertise in Domestic and Commercial Wastewater Any Project, Any Wastewater Application Wastewater poses a complex challenge, no matter whether it originates in a single house or a multifamily
More informationNEWS 2017 SANIFLO. Pumps and pumping stations
NEWS 2017 SANIFLO Pumps and pumping stations SFA, WORLD LEADER IN SANITARY FACILITIES MADE IN FRANCE For 60 years, the Société Française d Assainissement [French Sanitation Company] has worked on improving
More informationProcess engineering. Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system
Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system ACO. The future of drainage. The ACO system chain provides drainage solutions to meet tomorrow s environmental
More informationKESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation
INSTALLATION AND OPERATING INSTRUCTIONS KESSEL Grease Separator Euro G NG 1, 2 and 4 For underground installation KESSEL Grease Separator G according to EN 1825-1 NG 1,2, 4 - for underground installation
More informationAutomatic Waste Water Lifting Unit. Ama-Drainer-Box Mini. Type Series Booklet
Automatic Waste Water Lifting Unit Type Series Booklet Legal information/copyright Type Series Booklet KSB Aktiengesellschaft Pegnitz All rights reserved. Contents provided herein must neither be distributed,
More informationGrease separator. Chapter contents. Grease separator for freestanding. Separator. Grease separator
Chapter contents Separator for freestanding installation With complete disposal Mobile separator for food stall or marquee Basic design for disposal via the cover Extension stage 1 for disposal via direct
More informationBasement Pump & Drainage Catalogue
November 2016 Basement Pump & Drainage Catalogue The Waterproofing People [BPD-B-V1-11.16] 2016 Delta Membrane Systems Ltd. All rights reserved. Subject to modification without prior notice. CONTENTS 2
More informationDRAINAGE AND SEWAGE. DRENA-LINE Residential Technology
DRAINAGE AND SEWAGE DRENA-LINE Residential Technology 1 HIGH QUALITY IS OUR MISSION The Pentair Group is one of the world leaders in the design and manufacture of innovative products and systems used
More informationMULTISAN Fully automatic sewage and waste water pump
MULTISAN Fully automatic sewage and waste water pump Multisan is suitable for pumping waste water from toilets, bidets, showers and basins from rooms which are below the sewer level, or conditions where
More informationGrease disposal concepts. Grease separators. For full and partial disposal For free-standing or ground installation
Grease separators Grease disposal concepts Grease separators For full and partial disposal For free-standing or ground installation Selecting the correct separator Areas of application Hotels Restaurants
More informationMedical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345
External Dimensions: B = 530 mm D = 640 mm H = 1600 mm Inside Dimension: Useful space on top Useful space at the bottom B = 450 mm B = 450 mm D = 535 mm D = 535 mm H = 530 mm H = 530 mm Capacity: 280 l
More informationLaboratory Deep Freeze Storage Cabinet TC 230 Air circulated
External Dimensions: B = 600 mm D = 650 mm (at -30 C/-40 C: 760 mm) H = 1640 mm (at -30 C/-40 C: 1720mm) Internal Dimensions: B = 500 mm D = 500 mm H = 890 mm Capacity: 300 l Temperaturerange: Optional:
More informationChoosing the Right Pump
Choosing the Right Pump Pumps are used to move fluid from one destination to another. They come in many different shapes, sizes, and operated by either electric motor, engine, by hand or solar power. They
More informationKESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms
INSTRUCTIONS FOR INSTALLATION, OPERATION AND MAINTENANCE KESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms GB Page 1-18 Product
More informationCBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet
CBU144 Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717 Product specification sheet Version The Compact Booster Unit consists of the following modules, that
More informationLifting Station Type ABS Sanimax
1051-00 15970278EN (11/2015) EN Installation and Operating Instructions www.sulzer.com 2 Installation and Operating Instructions (Original Instructions) : R 202 MF 154 R 202/C MF 154HW MF 324 Contents
More informationExternal Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C
External Dimensions: B = 750 mm D = 700 mm H = 2100 mm Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm Capacity: 600 l Temperaturerange: 2 C to 20 C Housing galvanized sheet steel with high quality
More informationGRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz
GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview General data Performance range 4 Applications 5 Examples of applications 5 Wastewater definitions
More informationPlasma Freezer with air circulation TC 516 acc. to DIN 58375
These blood plasma storage cabinets are designed for DIN - compliant storage of already frozen blood plasma bags. External Dimensions: B = 600 mm D = 780 mm H = 2000 mm Internal Dimensions: B = 500 mm
More informationHeat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min
Heat on Air heaters from 400 Watt to 17 400 Watt Blowers from 1,45 m 3 /min to 16,5 m 3 /min BAK Thermoplastic Need-to-know Calculation of air heaters 1. Heat requirement calculation Formula: Q = m * c
More informationLaboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)
External Dimensions: B = 1500 mm D = 820 mm H = 2100 mm Inside Dimension: Room 1 B = 600 mm D = 670 mm H = 1330 mm Room 2 B = 600 mm D = 670 mm H = 1330 mm Capacity: 1500 l Temperature range: Room 1 2
More informationGRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz
GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview General data Performance range 4 Applications 5 Examples of applications 5 Pump overview
More informationProduct Data Sheet Adsorption Dryer DPS (A)
Version: 1.0.5 Author: Tassilo Tappe Date:13.07.2012 Field of application Adsorption dryers of the DPS series are designed for drying compressed air and nitrogen to pressure dew points of -25 C to -70
More informationOperation Manual. Trash Water Pump ARTICLE Image similar
Operation Manual Trash Water Pump ARTICLE 50781 Image similar Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further
More informationExternal Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm
External Dimensions: B = 600 mm D = 630 mm H = 2000 mm Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm Capacity: 328 l Temperaturerange: -15 C to -30 C Housing galvanized sheet steel with white
More informationGRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz
GRUNDFOS DATA BOOKLET Unilift CC, KP, AP Submersible drainage and effluent pumps 50 Hz Contents Product overview Unilift CC, KP, AP 3 General data Performance range 4 Applications 5 Examples of applications
More informationGRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions
GRUNDFOS INSTRUCTIONS Sololift2 C-3 Installation and operating instructions English (US) English (US) Installation and operating instructions Original installation and operating instructions. CONTENTS
More informationInstruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data
Instruction manual Submersible sump pump Safety instructions Application Electrical connection Installation Maintenance Technical data U 3 K /2 U 3 KS /2 U 3 K spezial /2 U 3 KS spezial /2 U 5 K /0 U 5
More informationChromatographic Air circulated Refrigerator, two-door TC 603
External Dimensions: B = 1500 mm T = 700 mm H = 2100 mm Internal Dimensions: B = 1345 mm (clear door with: 545 mm) T = 570 mm H = 1330 mm (lower edge of evaporator) Capacity: 1000 l Temperature Range:
More informationHL Anti-flooding valves 5/4" DN40 = DN32 = DN32 = DN40 = 280 DN32 DN32 = 350 DN40 DN40 = 350 DN32 = 90 DN40 = 95
5/4" DN40 = 80-315 DN32 = 80-315 DN40 = 350 DN32 = 350 DN40 = 280 DN32 = 285 29 DN40 DN32 HL Anti-flooding valves DN40 = 50-250 DN32 = 50-220 Basement and backflooding DN40 = 95 DN32 = 90 HL Hutterer &
More informationContent. 1 Basics. 2 Detailed Information on different types of Vacuum technologies. Vacuum sanitary installations. Vacuum sewer systems
Vacuum Technology - collection and transport of sewage by means of low pressure Christine Werner, Florian Klingel, Ulrike Mosel, Sebastian Hass Deutsche Gesellschaft für Technische Zusammenarbeit (GTZ)
More informationplumbing for greywater
plumbing for greywater october 2015 christina bertea ~union trained journeywoman plumber (1978) ~plumbing contractor (1996) ~greywater action singingwater@jps.net plumbing for greywater basic parts of
More informationC. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.
SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.
More informationHD 7/11-4 Cage Classic
HD 7/11-4 Cage Classic Long service intervals and high-quality components such as the crankshaft pump with ceramic piston are among the many strengths of the HD 7/11-4 Cage Classic single-phase high-pressure
More informationWaste water ejection unit
Waste water ejection unit Over ground box SWH 500/50-80 SWH 500/50-80 Operation manual Table of contents: Page Declaration of conformity... 3 1. General... 4 1.1 Introduction... 4 1.2 Enquiries and orders...
More informationGRUNDFOS. Multilift PRODUCTS. MSS, M, MOG, MD, MLD, MDG and MD1/V
GRUNDFOS Multilift PRODUCTS MSS, M, MOG, MD, MLD, MDG and MD/V GRUNDFOS The Grundfos MULTILIFT is a compact, powerful lifting station that offers a complete wastewater solution for commercial buildings
More informationCHAPTER 10 TRAPS AND INTERCEPTORS
CHAPTER 10 TRAPS AND INTERCEPTORS 1001.0 Traps Required. 1001.1 Each plumbing fixture, excepting those having integral traps or as permitted in Section 1001.2, shall be separately trapped by an approved
More informationMacerator Pumps & Lifting Station. Technical presentation Part 1
Macerator Pumps & Lifting Station Technical presentation Part 1 Index Brief history and product background. Product range & characteristics. Benchmarking with SFA range Installation & Servicing History
More informationChromatographic Air circulated Refrigerator, two-door TC 603
External Dimensions: B = 1500 mm T = 700 mm H = 2100 mm Internal Dimensions: B = 1345 mm (clear door with: 545 mm) T = 570 mm H = 1330 mm (lower edge of evaporator) Capacity: 1000 l Temperature Range:
More informationProduct Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)
Refrigeration Dryer 66 (-W) bis 2400 (-W) Version: 1.0.1 Author: Karsten Unger Date: 20.09.2013 Field of application Refrigeration dryers of the series are designed for drying compressed air flows up to
More informationData sheet: Wilo-RainSystem AF Comfort MC 304
Data sheet: Wilo-RainSystem AF Comfort MC 304 Pump curves Wilo-RainSystem AF Comfort H/m 50 Wilo-RainSystem AF Comfort Approved fluids (other fluids on request) Pure water without settling sediment Rainwater
More informationHDS 6/14 C. Large tilting aid. eco!efficiency mode. Economical and environmentally friendly even during longer periods
HDS 6/14 C Single-phase hot water high-pressure cleaner with Eco mode, 1-button operation, integrated tanks, Easy Press gun with soft grip, continuous servo-control pressure/water flow regulation, etc.
More informationAutomatic Waste Water Lifting Unit
Type Series Booklet 2331.55/4-EN Ama r -Drainer-Box 021 Automatic Waste Water Lifting Unit Above-floor-Box 021 Fields of Application Single Lifting Unit - Above-floor Box 021 F Automatic drainage of wash-basins,
More informationWISY. Rainwater Harvesting. Installation and Operating Instructions. English. instructions for the. rainwater units. these installation
ion Instructions Installation Instructions Installation I English ons Installation Instructions Installation Instructions ion Instructions Installation Instructions Installation I ons Installation Instructions
More informationSL S.S.N.51D
GRUNDFOS DATA BOOKLET SL1.8..265.2.52S.S.N.51D Grundfos Pump 9814549 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/seslfam/9814549/sl1-8--265-2-52s-s-n-51d.html
More informationHennecke description of day tanks and metering equipment used in conjunction with Rotamats supplied to Trane (Vidalia, GA)
Hennecke description of day tanks and metering equipment used in conjunction with Rotamats supplied to Trane (Vidalia, GA) 2013-09-16 Tank Station for Coil and Fan Door Production Item B ITEM NO. DESCRIPTION
More informationETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT
90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company
More informationVisit us at testo 835 Infrared and contact thermometer
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com testo 835 Infrared and contact thermometer Instruction manual 1. General information
More informationHD 5/12 C + Mobility. Accessory storage
HD 5/12 C + A new compact commercial machine for extended use. With its compact dimensions, robust construction and fantastic manoeuvrability, this unit is a credit to the compact class. 1 Mobility 3 Accessory
More informationProduct Data Sheet Refrigeration Dryer DFX
Version: 1.0.6 Author: Tassilo Tappe Date: 10.07.2012 Field of application Refrigeration dryers of the DFX series are designed for drying compressed air flows up to 14 bar(g) / 16 bar(g) to pressure dew
More informationSTACKS AND STACK VENTS
CHAPTER 9 VENTS SECTION 901 GENERAL 901.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of vent systems. 901.2 Trap seal protection. The plumbing
More informationProduct Data Sheet Adsorption Dryer DPS
Version: 1.6.0 Author: Tassilo Tappe Date : 05.07.2016 Field of application Adsorption dryers of the DPS series are designed for drying compressed air and nitrogen to pressure dew points of -25 C to -70
More informationThe Collection Chamber
The Collection Chamber The Collection Chamber connects the transit vehicle to the vacuum sewer system. Wastewater flows by gravity from four to six pickup points into a collection chamber. Located above
More informationLS Condensate Removal Pump INSTRUCTION MANUAL REVISION A
LS Condensate Removal Pump INSTRUCTION MANUAL 6-71-075-115 REVISION A CAUTION: Combustible liquids may not be pumped! The condensate pump may not be run dry, as this can destroy the bearings in a very
More information- Sewage and Sludge Pumps
- Sewage and Sludge Pumps Technology redefined range of Submersible Sewage and Sludge Pumps are designed to perform impecably in the worst of conditions. Global Approach Keeping in mind the causes of blockage
More informationDCS-100. intelligent damper control & monitoring system
DCS-100 intelligent damper control & monitoring system 02 //DCS-100 Introduction The Disys Technologies DCS-100 is a revolutionary new control system designed specifically for the fire/smoke damper controls
More information~256. Ventilator. Float valve. Plugged end (INLET) Straight connection DN kpa: 1.20 l/s (instantaneous value)
Date: 05 May 2009 Doc. 002190-2 TECHNICAL DATA 6543521 UNIT 2L, CONNECTION UPWARDS Mini-check Straight connection DN50 Rubber bend DN40 Connection DN40 83 ~195 35 Max. 3m ~256 Ø90 Evac Noback OUTLET Discharge
More informationAirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation
mfh systems modern floor heating AirUnit Decentralised domestic ventilation Installation instructions List of contents, Installation instructions Page 1. General information... 03 2. Function / planning
More informationProduct Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management
Product Data Sheet Refrigerant Dryer -ES 66 (-W) to -ES 660 (-W) with energy saving management Version: 1.6.0 Author: Karsten Unger Datum: 05.07.2016 Field of application Refrigeration dryers of the -ES
More informationHot water compact class HDS 5/12 C *AU
Hot water compact class HDS 5/12 C *AU Standard accessories: Spray gun Extended, Easy Press Spray gun with Softgrip insert High-pressure hose 10 m Spray pipe 550 mm Power nozzle SDS system Anti-twist system
More informationJUNG PUMPEN LIFTING STATIONS
JUNG PUMPEN LIFTING STATIONS POWERFUL AND DEPENDABLE RESIDENTIAL TECHNOLOGY LIFTING STATIONS Product overview: Lifting stations the full range: Lifting stations are designed to dispose of wastewater in
More informationDESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES
2.05 PLUMBING GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.05 It is expected that the plumbing design professional will conform to accepted good engineering design practices.
More informationPrimusCenter DWC7000. Domestic Water Centre. Product specification sheet
PrimusCenter DWC7000 Domestic Water Centre Product specification sheet Construction The domestic water centre consists of: R1 filter connection fitting with backflow preventer FK7000 filter combination
More informationSafety vacuum drying oven for flammable solvents
VDL series 53 Vacuum drying ovens Safety vacuum drying oven for flammable solvents A BINDER safety vacuum drying oven of the VDL series ensures maximum safety when drying organic solvents standard with
More informationPressure Sewer Systems
Pressure Sewer Systems Built under ISO9001 Quality Management System Built to WSAA Standards NSF/ANSI 46 Certified Pressure Sewer Systems Pressure Sewer Systems are one of the most economical and environmentally
More informationACO Building Services
ACO Building Services Grease separators Grease disposal concepts Grease separators For full and partial disposal For free-standing or ground installation Grease separators from ACO Building Services Areas
More informationABS lifting station Sanimax
105100 15970278GB (09/2011) GB Installation and Operating Instructions www.absgroup.com Installation and Operating Instructions (Original Instructions) R202 R202/C MF154 MF324 Contents 1 General... 3 1.1
More informationMASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:
SECTION 221319 - SANITARY WASTE PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following sanitary drainage piping specialties: 1. Backwater valves. 2. Cleanouts. 3. Floor
More informationHD 5/12 C Plus. Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle.
HD 5/12 C Plus Compact, high performance pressure washer with unique stand-up or lay-flat operating positon and large carry handle. 1 Mobility 3 Accessory storage The integrated carrying handle on the
More informationSUBMERSIBLE PUMPS For water with particulate matter 2 pole - 50 Hz 2 ranges : SS 304 & SS 316 L
operating limits Flow up to: m /h Head up to: m w.g. Liquid temperature range: + to 5 C* Specific gravity of liquid:.5 max. ph of liquid: - Max. immersion depth: m Free passage: Ø mm ND of discharge port:
More informationMonitoring Solutions
GSM Systems Monitor: Temperature, Humidity, Power, Water, Smoke, Carbon Monoxide and More September 2016 Table of Contents GSM Systems... 3 Argon 100 GSM... 3 Ares 12 & 14 GSM... 4 Poseidon2 4002... 5
More information1 Exam Prep Plumber s Handbook Tabs and Highlights
1 Exam Prep Plumber s Handbook Tabs and Highlights These 1 Exam Prep Tabs are based on the Plumber s Handbook Revised 2006. Each Tabs sheet has five rows of tabs. Start with the first tab at the first
More informationPLUMBING INSTALLATIONS
PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT PLUMBING INSTALLATIONS A homeowner guide to plumbing requirements for single-family dwellings November 2017 contents Permit Requirements... 3 Inspection Requirements...
More informationInstallation and Operating Instructions
Installation and Operating Instructions CHEOPS for Pre-Filter Module Order No. CHEOPS 0015 CHEOPS and Main Filter Module Order No. CHEOPS 0010 Before putting the filter system into operation please carefully
More information290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING
Fresh air boxes ALB Comfortable climate with pre-heated, filtered supply air. Ingeniously practical: Supply air, heating and filter in a single unit. For direct in-duct mounting. The fresh air boxes ALB
More informationAir Comfort. Installation instructions (English) A
Air Comfort Installation instructions (English) WWW.BRINKAIRFORLIFE.NL 614788-A This appliance may be used by children as of 8 years of age, persons of reduced mental or physical capacities and those of
More informationK Water-cooled, designed for convenience with extensive accessories for heavily soiling (e.g. weathered facades). Ideal for large areas.
K 5.700 Water-cooled, designed for convenience with extensive accessories for heavily soiling (e.g. weathered facades). Ideal for large areas. TECHNICAL DATA AND EQUIPMENT K 5.700 Technical data Order
More informationMINIMUM REQUIREMENTS FOR ADOPTABLE WASTEWATER PUMP STATIONS
MINIMUM REQUIREMENTS FOR ADOPTABLE WASTEWATER PUMP STATIONS Date: Site Name: Address: Note that this document is not a technical specification and is not a complete checklist for all the specified requirements.
More informationC B SOLARTHERMAL. Solar thermal systems
66 66 Steca Elektronik GmbH 87700 Memmingen Germany Fon +49 (0) 81 8558-0 Fax +49 (0) 81 8558-12 www.stecasolar.com 67 E A D C B Legend: A Collector B Solar Station C Storage tank D Central-heating boiler
More informationSUPPLEMENTARY INSTRUCTIONS
www.burcam.com 2190 Dagenais Blvd.West TEL: 514.337.4415 LAVAL (QUEBEC) FAX: 514.337.4029 CANADA H7L 5X9 info@burcam.com SUPPLEMENTARY INSTRUCTIONS MODEL 450475 Dear consumer, We thank and congratulate
More informationSOLOLIFT2. Grundfos bring you a macerator that is the most powerful, reliable and service friendly on the market, delivered by a name you can trust
Grundfos bring you a macerator that is the most powerful, reliable and service friendly on the market, delivered by a name you can trust - GET INTRODUCED TO A NEW GENERATION Up until now, macerators have
More informationCold water compact class HD 5/12 C
Cold water compact class HD 5/12 C Convenient, mobile, versatile: the HD 5/12 C cold water high-pressure cleaner for vertical and horizontal operation. With accessory storage, brass cylinder head and automatic
More informationLaboratory Refrigerator/Deep Freezer TC 802
External Dimension: B = 600 mm D = 615 mm H = 2000 mm Inside Dimension: Useful space on top Useful space at the bottom B = 440 mm B = 431 mm D = 435 mm D = 435 mm H = 1105 mm H = 597 mm Capacity: 254 l
More informationGreenleaf 600 Macerator Toilet Waste Pump
Greenleaf 600 Macerator Toilet Waste Pump Website: Contact: www. greenleaftrade.co.nz Introduction The Greenleaf 600 toilet macerator waste pump is suitable for use in domestic waste / sewerage installations.
More informationEW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS
Design Hydronic meters of the EW447-452 Series consist of: Electronic energy integrator with fixed cable connection to the volume measuring component, supply and return temperature probe Mechanical volume
More informationSL EX.4.51D
GRUNDFOS DATA BOOKLET SL1.1.1.75.EX.4.51D Grundfos pump 962669 Thank you for your interest in our products. Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/sl1/962669/sl1-1-1-75-ex-4-51d-c.html
More informationBoiler module and operator-control unit KM 921 with CUI 9xx for heating boilers
Boiler module and operator-control unit with for heating boilers Product brochure GB 10.5.2.2 Edition 02.04 odulating burner control unit with integral or external ignition Diverse possible applications
More informationBuilding Utilities 1 Plumbing and Sanitary Systems
Building Utilities 1 Plumbing and Sanitary Systems Taken from UST Architecture exams by Arch. Rafael Alli Recommended review material for UST Preboard Exam Prepared by: arkireviewph.multiply.com Types
More informationHDS 5/11 UX. Entry-level, highly portable hot water pressure cleaner with integrated hose reel. Integrated hose reel. Innovative upright design
HDS 5/11 UX Entry-level, highly portable hot water pressure cleaner with integrated hose reel 1 2 3 4 1 2 Integrated hose reel Convenient, secure pressure hose storage. Ensures ergonomic operation. Fine-mesh
More informationCleaning System. Amajet. Type Series Booklet
Amajet Type Series Booklet Legal information/copyright Type Series Booklet Amajet All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed
More informationHD 5/11 C Plus. Automatic pressure cut-off. Pump technology
HD 5/11 C Plus Compact cold-water high pressure cleaner. With its compact dimensions, robust construction and greatest possible manoeuvrability, this unit is a credit to the compact class. 1 Automatic
More informationConstant climate chambers
KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.
More information