Installation Instructions SPA BROADWAY FAMILY
|
|
- June Walton
- 5 years ago
- Views:
Transcription
1 Installation Instructions SPA BROADWAY FAMILY 1
2 CONTENTS GENERAL SPECIFICATIONS RECEIVING THE EQUIPMENT PREPARING THE PLACE FOR THE INSTALLATION POSITIONING THE SPA ELECTRICAL CONNECTIONS Earth connection Equipotential connection Mains situation Mains connection HYDRAULIC CONNECTION FILLING AND EMPTYING THE SPA VENTILATION... 5
3 This spa has been designed, manufactured and checked by our technical staff. It must be fitted in compliance with the regulations in force, and the corresponding instructions should be followed. Fig. BREACH OF THIS CONDITION RENDERS THE PRODUCT WARRANTY NULL AND VOID. This spa has been designed for private use. GENERAL SPECIFICATIONS AIR MASSAGE: - 1 Blower (800 W W). 1x30V bottom holes. WATER MASSAGE: - pumps: Kw/30V. 1,1Kw/30V. - JETS: - fixed ozone mini jet - 1 pcs. - fixed mini jets - 4 pcs. - small rotational jets - 1 pcs. - 3,5 adjustable rotating stream jets - 6 pcs /8 directional jets - pcs /8 pulsative-rotational jet - 1 pcs. - 4 large pulsative-rotational jets - pcs. - large geyser - 1 pcs. - 6 hydromassage aeration regulators - hydromassage diverters. DISINFECTION: - 1 ozone generator (10W) 50mg/h. FILTERING AND HEATING: - Filter cartridge. WATER HEATING ELEMENT: - kw 30 V SPECIFICATIONS: - Capacity Ltrs. - Dimensions - 160/180/90 mm (Fig. ). - Weight Kg (sin agua). - No. of people Consumo eléctrico máximo: 6, Kw/30V. Antifrost system Minimal temperature of SPA is 15 C. If the temperature of water is below 15 C electronic system starts automatically the blower & pump. Between 15 and 1: blower operates for 1 minute every 10 minutes. Between 1 and 9: blower operates for 1 minute every 60 minutes. Between 9 and 6: blower operates for 1 minute every 30 minutes. Lower than 6: blower operates for 1 minute every 15 minutes. 1. RECEIVING THE EQUIPMENT The spa should reach its destination in its original packaging. Medidas de embalaje son: 190/190/1310 mm. Once the packaging has been removed, check the spa fully before it is installed and report any anomaly. Do not lift the spa using the filter equipment or the pipes. Do not stand the spa on its edge. Always stand it on its legs. During the installation, check that the interior of the spa is protected by the covering included with the equipment. The electrical installation and pipe connections must be carried out by authorised installers. Fig SECTION 1 + GEYSER SECTION SECTION SECTION 4 SECTION 5 SECTION 6 1 CASCADE CASCADE 3
4 3 1 JETS 3 JETS 1 JETS AIR LIGHT CLOCK ECONO FILTER UP DOWN. PREPARING THE PLACE FOR THE INSTALLATION The Broadway Family spa can function indoors and outdoors. It must be installed on a firm base to prevent it from sinking. When choosing the location for the spa, a series of requirements must be taken into account: - If you have decided to install the spa indoors, bear in mind the thoroughfares required for transporting it to its final location. - The electrical connection of the equipment must be carried out with a 3 conductor cable with a section of 4 mm and ready for 30 VAC (the nominal power consumed by the standard equipment is equal to 6, kw). - An earth connection compliant with current legislation is essential. - Access to interior components through the side panels for postinstallation maintenance. - You must also bear in mind how you are going to fill and empty the spa. The floor must be level. (Fig. 3). - There must be adequate ventilation in closed interior locations. - You must bear in mind the materials used on the wall and ceilings, since the humidity generated by the spa requires steam-resistant materials. - Due to unavoidable splashing, the floor must be highly-resistant to water, such as tiles or plastic coverings. If carpets are used, they must be treated to avoid bacteria from damp. Use special sailing carpets or rugs. Parquet or wooden floors are not advisable unless they have been duly treated for this kind of use, such as wood for gardens or outdoor buildings. In any case, make sure that the floor has a gradient of % towards a drain installed in the room. 3. POSITIONING THE SPA - For appropriate operating conditions, the spa must be positioned on a carefully levelled, firm base. - The weight of the full spa and with three people in it is approximately 1000 kg. This weight is supported on 9 points - the legs - with a load on the floor of 400 kg/m. - Level the spa by adjusting the legs (Fig. 3). - Position the spa in a way that best enables maintenance through the wooden panels. -When installing the spa in a corner or next to a side wall, remember Fig. 3 to leave 0.5 metres or connection or installation work or fit trap doors with a minimum size of 1700x700 mm for accessing all the sides for post-installation maintenance. - This spa cannot be embedded. Do not obstruct access to the side panels. The following diagrams show the distribution of the support points and the position of the spaces inside the spa. 4. ELECTRICAL CONNECTIONS The electrical installation must be carried out by an authorised electrician. The internal connections of the equipment have been made at the factory (Fig. 4). The electrical installation of the spa must be protected by a 30 ma differential switch and a 30 A magnetothermal switch with omnipolar disconnection devices and a distance between contacts of at least 3 mm. Both switches must be situated outside the volumes as shown in fig. 5 Fig. 4 Water connection 1/ for water filling Sewage connection 50 mm ~ 30 V (3 x 4 mm ) electric connection with protection of circuit breaker (30 ma cut-off value) Skimerofiltr 4.1. EARTH CONNECTION For the circuit-breaker to function correctly, there must be an installation with an earth connection in the home. 4.. EQUIPOTENTIAL CONNECTION The spa has a terminal for a 4 mm section cable which joins all the metal parts of the apparatus electrically and which must be connected to the equipotential connections grid of the home. This terminal must not be connected to the mains supply earth of the spa MAINS SITUATION The mains supply cable of the spa must be connected to a fixed installation. A plug is not acceptable. The electrical installation must be compliant with current legislation governing low voltage. For this, it is important to bear in mind that four protection blocks are established where the spa is to be installed, defined as shown in the following diagram, (fig. 5). Where block 3 is appropriate for the mains, or a false ceiling with a height of over.5 m MAINS CONNECTION For the mains connection, the following must be taken into account: - The power supply of the spa must be permanently connected to a fixed electrical conduit. - A cable compliant with the corresponding low voltage standards 4
5 must be used. Remember that the green and yellow earth wire must have a length at least 40 mm longer than the neutral cables so that in the case of the cables being pulled, it is the last to be disconnected. - If the mains connection is made below the spa, it must be done by means of a connection system with a protection level of at least IPX5 and it must be located at more than 0 cm from the floor. 6. FILLING AND EMPTYING THE SPA Never use the air blower circuit to fill the spa. Fig. 6 It is very important to make sure that the electrical connections are completely watertight (IPX5 level) Fig. 5.. The spa can be connected to the water mains pipes, permanently in use, or it can be filed and emptied by flexible pipes that can be removed after use. Figure 8 shows the filling point of the spa with the letter I. Figure 8 shows the emptying point of the spa with the letter V, which can be permanently or temporarily connected to the conduit system. Said emptying outlet must be connected to the general drain in the room or house. We recommend the use of a U-bend to avoid bad smells. The empty/fill taps are marked with the letter T... For your convenience, for both the filling and emptying operations, we recommend the installation of taps outside the spa enclosure. This will avoid the need for removing the panels. N.B. The space below the spa tank is considered volume 3 as a tool is required to remove the panels. 5. HYDRAULIC CONNECTION Filling the spa can be done directly by garden hose or by use inlet check valve (fig. 6). For the connection, use PVC pipes and appropriate adhesive for this type of material. Do not use metal pipes. Make sure that there are no accumulated bags of air or water in the fill or empty connection. The emptying circuit must guarantee perfect emptying and, if the use of the drain so allows, a U-bend to prevent bad smells. Also, where required, the fill and empty circuits must also be fitted with anti-backflow devices to prevent retrosuction.. Once the installation is complete, start up the equipment and check that the joints are watertight. Mark the water level in the spa, leave it for 4 hours and check that it has not gone down. 7. VENTILATION The possible high temperature of the water in the spa (approximately 39 ºC) leads to steam condensation. The spa room must have adequate ventilation. If it does not, it is recommended that you install a dehumidifier to keep the air humidity at a constant temperature and prevent steam from condensing on the ceiling and on the floor. For the correct maintenance of the wood, the relative air humidity in the room must be kept below 65% when the spa is not being used. During use and due to the evaporation caused by the hydromassage and the movement of the water, this value normally reaches 90 or 95%. The air humidity can be kept constant by the use of fans controlled by hygrostats or dehumidifiers adapted to the size of the room. Your installer or distributor can offer you advice on this. If the room has air conditioning, the condenser is not necessary. If the spa is outdoors or in an open space, these apparatuses are not necessary. The following drawing (fig. 7), shows the spa s filter circuit. 5
6 Fig. 7 Skimmer filter Water pump Ozone jet Suck Water + ozone Injektor Ozonizer Ozone Water Filter circuit in the Broadway Family Fig. 8 HYDRAULIC CONNECTION D P D G F I E Z Z1 K R H V T D. air regulators P. Control panel E. Blower R. Heating element F. Filter + skimmer T. Empty/fill tap G. Ozone generator V. Empty/fill H. Filter + hydromassage pumps Z1. Maintenance valves (pump inlet) K. Control box Z. Maintenance valves (outlet) 6
7 Fig. 9 SPA BROADWAY FAMILY ELECTRICAL DIAGRAM (30 V Single phase) ON 1 34 RTC AT 5A/50VAC L N PE L N PE L N PE L N PE L N PE COMP CIRC AUX TANK BLOWER PUMP OZONE ŚWITAŁO PE JETS 3 JETS 1 JETS AUX LIGHT CLOCK ECONO FILTER UP DOWN WATER LEVEL SENSOR (PE100017) + ~~ _ Transformer N L 630mAT HI/LI PROBE COMP TANK LEVEL VAR PUMP VAR BLOWER FLUX PROGRAMMING KEY AUX KEYPAD TEMP PROBE 30A/50VAC ASTREL IC BUS LEVEL SENSE TSC 9 KEYPAD SD INTERFACE 5A/50VAC 5AT MAIN KEYPAD AT 6,3AT 6,3AT 3 1 0AT L/HI N PE PUMP 1 30A/50VAC L/LO N PE PUMP 1 30A/50VAC L/HI N PE PUMP 30A/50VAC 0AT L/LO N PE PUMP Do not cut R91 R10 R90 R119 R89 R118 R88 R94 L N PE L N PE INPUT VOLTAGE MASSAGE PUMP 1 SAM -00 /4 (PP ) MASSAGE PUMP (PP310007) MAINS SUPPLY 30VAC 50Hz Wire: 3 x 4mm KEYPAD TSC4 (PE ) HEATER KW 30VAC (PE600013) HEATER Multicolor lamp (PE ) OZONE GENERATOR 30V 50/60Hz (PE ) BLOWER 30V 50/60Hz 1,1kW (PP500001) 7
8 Roca Sanitario, S.A. Avda. Diagonal, Barcelona España Roca S.R.L. Via Leonardo da Vinci, Casarile (Milano) Italia Tel Fax Roca Cerâmica e Comercio, S.A. Serviços Comerciais Rua José Duarte Lexim, Lote Odivelas Codex Apartado de Correios Odivelas Codex Portugal Tel Fax Roca GmbH Feincheswiese Staudt Deutschland Tel. +49.(0) Fax.+49.(0) Roca Polska Sp. z o. o. ul. Wyczolkowskiego 0, Gliwice Polska Tel. +48.(0) Fax.+48.(0) Roca Argentina S.A Camino General Belgrano, Lanús Este Buenos Aires Argentina Tel. +54.(0) Fax:+54.(0) Roca Limited Samson Road Hermitage Ind. Estate Coalville, Leics. LE67 3FP United Kingdom Tel. +44.(0) Fax.+44.(0) Roca S.A.R.L. BP Cergy Pontoise Cedex France Tél. +33.(0) Fax.+33.(0) (0) ROCA Maroc, S.A. Route de Marrakech, km.5 B. P Settat Maroc Telf : +1.(0) (0) Fax : +1.(0) Kalevit Roca Saniter Seramik Sanayi, A.S. Büyükdere Cad. Kaleseramik Binasi 8060 Levent Istanbul Turkey Tel Fax S (available in Spain only) 8 (available in Spain only)
Installation Instructions SPA BROADWAY COMPACT
Installation Instructions SPA BROADWAY COMPACT 1 CONTENTS GENERAL SPECIFICATIONS... 3 1. RECEIVING THE EQUIPMENT... 3 2. PREPARING THE PLACE FOR THE INSTALLATION... 3 3. POSITIONING THE SPA... 3 4. ELECTRICAL
More informationInstallation Manual SPA BROADWAY MAXI
Installation Manual SPA BROADWAY MAXI 1 2 INDICE 1. RECEIVING THE EQUIPMENT... 4 2. PREPARING THE PLACE FOR THE INSTALLATION... 4 3. POSITIONING THE SPA... 7 4. ELECTRICAL CONNECTIONS... 7 4.1. Earth connection...
More informationInstallation Instructions SPA BROADWAY COMPACT
Installation Instructions SP BRODWY COMPCT 1 CONTENTS GENERL SPECIFICTIONS... 3 1. RECEIVING THE EQUIPMENT... 4 2. PREPRING THE PLCE FOR THE INSTLLTION... 4 3. POSITIONING THE SP... 4 4. ELECTRICL CONNECTIONS...
More informationInstructions for Installation BROADWAY SPA
Instructions for Installation BROADWAY SPA 1 TABLE OF ONTENTS ENERAL SPEIFIATIONS... 3 1. REEIVIN THE EQUIPMENT... 4 2. PREPARIN THE PLAE FOR THE INSTALLATION... 4 3. POSITIONIN THE SPA... 4 4. ELETRIAL
More informationInstallation Instructions SPA BROADWAY FAMILY
Installation Instructions SP RODWY FMILY 1 CONTENTS GENERL SPECIFICTIONS... 3 1. RECEIVING THE EQUIPMENT... 4 2. PREPRING THE PLCE FOR THE INSTLLTION... 4 3. POSITIONING THE SP... 4 4. ELECTRICL CONNECTIONS...
More informationInstallation Instructions SPA BROADWAY ROUND
Installation Instructions SP BRODWY ROUND 1 ONTENTS GENERL SPEIFITIONS... 3 1. REEIVING THE EQUIPMENT... 4 2. PREPRING THE PLE FOR THE INSTLLTION... 4 3. POSITIONING THE SP... 4 4. ELETRIL ONNETIONS...
More informationUser s Handbook BROADWAY COMPACT
User s Handbook BROADWAY COMPACT 1 Congratulations! and thank you for buying this ROCA product In keeping with its creative and innovative spirit, ROCA SANITARIO, S.A. has taken one step further in its
More informationUser s Handbook BROADWAY COMPACT
User s Handbook BROADWAY COMPACT Congratulations! and thank you for buying this ROCA product In keeping with its creative and innovative spirit, ROCA SANITARIO, S.A. has taken one step further in its commitment
More informationSPA YARD. Installation manual
Installation manual 2 TABLE OF CONTENTS INTRODUCTION...3 1. SPECIFICATIONS...3-4 2. RECEPTION OF THE EQUIPMENT...4 3. PREPARATION OF THE INSTALLATION LOCATION...4-7 4. ELECTRICAL CONNECTIONS...8 4.1. EARTH
More informationUser s Handbook SPA BROADWAY ROUND
User s Handbook SPA BROADWAY ROUND Congratulations! and thank you for buying this ROCA product In keeping with its creative and innovative spirit, ROCA SANITARIO, S.A. has taken one step further in its
More informationSPA DE USO PRIVADO SPA FOR PRIVATE USE SPA POUR UN USAGE PRIVÉ SPA FÜR PRIVATE NUTZUNG SPA PER USO PRIVATO SPA PARA USO PRIVADO SPA VOOR PRIVE-GEBRUIK
SPA DE USO PRIVADO SPA FOR PRIVATE USE SPA POUR UN USAGE PRIVÉ SPA FÜR PRIVATE NUTZUNG SPA PER USO PRIVATO SPA PARA USO PRIVADO SPA VOOR PRIVE-GEBRUIK MANUAL DE INSTALACIÓN INSTALLATION MANUAL MANUEL D
More informationAUTOMATIC GRANULAR ICE FLAKER
AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24480 rev. 01 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on choosing a
More informationMODULAR AUTOMATIC GRANULAR ICE FLAKER
MODULAR AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 03 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having
More informationSG User Manual
SG 0004-5 User Manual The spa equipment requires a 44 amp outlet, preferably dedicated to the spa. Carefully read all of the instructions before enjoying the spa. WARNING: Operating the system without
More informationPORTAPAC / DELTA HOT. Installation and Operation Manual. ! WARNING
PORTAPAC / DELTA HOT Installation and Operation Manual! WARNING This equipment must be installed and serviced by a qualified technician. Improper installation can create electrical hazards which could
More informationEN: This Datasheet is presented by the m anufacturer. Please v isit our website for pricing and availability at ore.hu.
EN: This Datasheet is presented by the m anufacturer. Please v isit our website for pricing and availability at www.hest ore.hu. PE bistable - small, strong, smart Miniature PCB Relay PE bistable 1pole
More informationAUTOMATIC MODULAR ICE FLAKER
AUTOMATIC MODULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 08 It is strictly forbidden to reproduce this instruction manual or any part thereof. 1 5 3 4 Mod. N. V. W 2 2 M8 18 8 18 M8 M8 3 ~ 200
More informationAUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS
AUTOMATIC ICE-CUBE MAKER - INSTRUCTIONS AND WARNINGS Dear Customer, Congratulations on having chosen a quality product which will certainly fully meet your expectations. Thank you for having purchased
More informationDEHUMIDIFIER DT 850 DIRECTIONS FOR INSTALLATION AND USE
DEHUMIDIFIER DT 850 DIRECTIONS FOR INSTALLATION AND USE 1 SUMMARY 1. GENERAL..... 3 1.1 General terms of delivery.... 3 1.2 Voltage... 3 1.3 Standards. 3 2. DESCRIPTION.... 3 2.1 Presentation..... 3 2.2
More informationINSTALLATION AND OPERATION MANUAL FOR HUUM DROP ELECTRIC SAUNA HEATER
INSTALLATION AND OPERATION MANUAL FOR HUUM DROP ELECTRIC SAUNA HEATER 2 Table of Contents 1. THINGS TO CHECK BEFORE INSTALLATION... 2 2. INSTALLATION... 2 3. CONTROLLING THE HEATER... 5 4. GUARD RAILS...
More informationYour Blast Vac Pro. Your Blast Vac Pro
Your Blast Vac Pro Your Blast Vac Pro Product code: V02364 03/13 JML JML House, Regis Road, London NW5 3EG Tel: 020 7691 3800, Fax: 020 7691 3801 E-mail: info@jmlgroup.co.uk Web: www.jmldirect.com Instructions
More informationDRAFT INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information
INSTALLATION INSTRUCTIONS Solid-State Series!! NOTE!! Covers the following models: " CS6100 - CS7100 " CS6200 - CS9200 " CS6220 - CS9220 " CS6230 - CS9230 " CS6500 - CS7500 " CS6330 - CS9300 " CS9400 -
More informationRif Cod i220-0
15 52 50 6 13 53 51 2 9 8 3 20 19 18 5 1 7 14 10 4 17 Rif Cod 1 0010060 2 0060287 3 0060310 4 0080003 5 0080004 6 0080051 7 0080053 8 0080410 9 0080413 10 0080430 11 0080432 12 0080434 13 0080435 14 0080436
More informationINSTRUCTION. Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors. Danfoss heating cable mat type 100/150
INSTRUCTION GB Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors NB! Read page 2 before installing the product if you intend to connect 2 mats to the same thermostat Danfoss
More informationInstruction manual for downdraft hood
Instruction manual for downdraft hood Model code: BODY / DD600BK - BODY / DD900BK BODY / DD600SS - BODY / DD900SS Contact Caple on 0844 800 3830 or for spare parts www.4caple.co.uk The symbol on the product
More informationSafety Warnings & Advice 3 Your Blast Vac Pro 4 Care & Cleaning 13 Using Your Vacuum 8 Troubleshooting 14 Guarantee 14 Technical Information 15
Thank you for purchasing Blast Vac Pro from JML. To ensure you enjoy the best performance from this combination vacuum cleaner and blower, make sure you read these instructions in full before use and keep
More informationInstallation Guide. Heating cables. Thin concrete (< 3 cm) Intelligent solutions with lasting effect. Visit DEVI.com
Installation Guide Heating cables Thin concrete (< 3 cm) Intelligent solutions with lasting effect Visit DEVI.com Table of contents 1 Introduction.................... 2 1.1 Safety Instructions...............2
More informationINSTALLATION AND OPERATION MANUAL
INSTALLATION AND OPERATION MANUAL Flow water heaters type PERFECT MIX 3,5-4,0-4,5-5,0-5,5 kw 1. Purpose and description Flow water heaters type PERFECT MIX 3.5-5.5 kw are intended for supplying hot water
More informationUponor Comfort E AL-Foil Mat
Uponor Comfort E AL-Foil Mat Contents Important notes on the intended use, safety and warranty...3 Intended use...3 Uponor Declaration of Warranty...3 System description...4 Floor construction...4 Technical
More informationIndex. page 8. 1 Description of appliance. Description of accessories. page 4. 3 Precautions for use. page 5. 4 Getting started
Index 1 Description of appliance page 2 2 Description of accessories page 3 3 Precautions for use 4 Getting started page 4 page 5 5 Practical use of the accessories page 5 6 Continuous refilling page 6
More informationCONTENTS CONSIDERATIONS. General Plumbing Component Connection ILLUSTRATION. Control System CONFIGURATION. Voltage Verification CONNECTION
AIR SERIES SYSTEM INSTALLATION MANUAL CONTENTS CONSIDERATIONS General Plumbing Component Connection 2 2 2 ILLUSTRATION Control System 3 CONFIGURATION Voltage Verification 4 CONNECTION Component Connection
More informationDEHUMIDIFIER DESHUMIDIFICATEUR DESHUMIDIFICADOR
DEHUMIDIFIER DESHUMIDIFICATEUR DESHUMIDIFICADOR Instructions for use Mode d'emploi Instrucciones para el uso 1 IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always
More informationAUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM
AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM INSTRUCTIONS AND WARNINGS 24481 ed. 11-2007 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear
More informationAUTOMATIC ICE-CUBE MAKER
AUTOMATIC ICE-CUBE MAKER INSTRUCTIONS AND WARNINGS 24478 ed. 11-2007 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having chosen
More informationRead this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS
PW1370TD 2 EN Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS 3 E3 E1 C3 A1-A2-A3-A4 B4 B1 B5 B2 C1 B3 D 1 4 1 2 3 4 5 6 7 Ø13
More informationTABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾
CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.
More informationSingle-side powered heating cables
E DM Single-side powered heating cables Power output of 10 W/m. Characteristics and application ELEKTRA DM heating cables are manufactured according to IEC800 standard. They consist of a thin heating cable
More informationPro6 Duo. Stampa Novaprint - Tel cod USER MANUAL
Pro6 Duo Stampa Novaprint - Tel.0424-539449 - www.novaprint.it cod.10161031310 USER MANUAL 9. Troubleshooting PROBLEM CAUSE SOLUTION Boiler fails to heat up. Device not plugged in. Button 3 and/or 4 not
More informationWater Bath SWB1 SWB2 SWB3 SWB1D SWB2D SWB3D. Instructions for use Version 2.0. water bath SWB2D. mains on on. press to set. set. off.
Water Bath SWB1 SWB2 SWB3 SWB1D SWB2D SWB3D Instructions for use mains on on off press to set set load 39.9 0 40 C 20 60 80 100 C over temp water bath SWB2D Version 2.0 Water Baths SWB1, SWB1D, SWB2, SWB2D,
More informationDEHUMIDIFIER DESHUMIDIFICATEUR DESHUMIDIFICADOR
DEHUMIDIFIER DESHUMIDIFICATEUR DESHUMIDIFICADOR Instructions for use Mode d'emploi Instrucciones para el uso 1 2 IMPORTANT SAFEGUARDS When using electrical appliances, basic safety precautions should always
More informationHeating Mats. Single-side power supply Double-side power supply
TThe Heating Mats Single-side power supply Double-side power supply AApplication The heating mats may be used as the basic heating system or they may supplement the existing system. The most often they
More informationInstallation Instruction
GB/DAS Installation Instruction Devimat DTIF 100/150 Heating cable mats for thin floors NB! Read page 3 before installing the product if you intend to connect 2 mats to the same thermostat 1 Devimat 100/150
More informationSMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS
SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS CONTENTS 1. INTRODUCTION... 5 2. WARNINGS... 6 3. GENERAL DESCRIPTION... 7 4. INSTALLATION... 8 5. LUMINOUS INDICATORS AND COMMANDS... 9 6. DIP-SWITCH
More informationSpa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)
Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert) P.N. 7876C (export) February 12, 2015 For Spas equipped with BP2100, BP6013 controllers and Spa Touch panel. Spa
More informationAUTOMATIC MODULAR SCALE ICE MAKER
AUTOMATIC MODULAR SCALE ICE MAKER INSTRUCTIONS AND WARNINGS 24850 ed. 06-2012 It is strictly forbidden to reproduce this manual or any part thereof. Dear Customer, Congratulations on having chosen
More informationDear Customer, Congratulations on having chosen a top-quality product, which is sure to live up to your expectations. Thank you for having purchased one of our products. Please read this instruction manual
More informationClosing procedures for in-ground pools
Closing procedures for in-ground pools Note: Carefully read this entire document before proceeding with the closure of your pool. In order to avoid unpleasant surprises, please check with your insurance
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationI N S T R U C T I O N S
INSTRUCTIONS HIPPO Deluxe Room Steam Vaporiser Congratulations on your purchase of the HIPPO Deluxe Room Steam Vaporiser. Before using this appliance, read the following instructions carefully as they
More informationAUTOMATIC MODULAR ICE-CUBE MAKER
AUTOMATIC MODULAR ICE-CUBE MAKER INSTRUCTIONS AND WARNINGS 24851 ed. 06-2012 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having
More informationUSE AND MAINTENANCE MANUAL
USE AND MAINTENANCE MANUAL SUPER MINI WARNING The manufacturer has the right to modify this manual without being obliged to update the previous editions.. IDENTIFICATION PLATE DALLA CORTE S.r.l Via Broglio,
More informationEC Box Fan www.flaktwoods.com/oandm Safety, Installation, Operation and Maintenance Instructions CONTENTS Paragraphs Safety 1 Handling/Storage 2 Installation (Mechanical) 3 Fig. 1: Fig. 2: Tilt Mechanism
More informationINSTALLATION AND MAINTENANCE MANUAL BLITZ FD_
INSTALLATION AND MAINTENANCE MANUAL IST 03 F 017-01 BLITZ FD_ Aluminium electric radiators with heat transfer fluid GB Dear customer, Thank you for choosing our product. Read this manual carefully before
More informationCROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15
CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15 COMPACT PLUS 10 and 15 Litre Unvented Under and Over Sink Water Heater INSTALLATION AND USER GUIDE 1 DIMENSIONS 10L - 250mm 15L - 310mm 100mm 80mm 410mm
More informationInstallation Guide. Heating cables. Pipe tracing. Intelligent solutions with lasting effect. Visit DEVI.com
Installation Guide Heating cables Pipe tracing Intelligent solutions with lasting effect Visit DEVI.com Table of Contents 1 Introduction.................... 3 1.1 Safety Instructions...............3 1.2
More informationEVAPORATIVE COOLER PUMPS
EVAPORATIVE COOLER PUMPS ebmpapst Evaporative Cooler Pump EBMALPHA $144.65 @ 1. metre Head @ 2. metre Head Power Supply 32 litres/min 25 litres/min 24V/1/5Hz Nominal Watts 5 watts Outlet Connection 2mm
More informationTARGA. Extraordinarily functional
TARGA Extraordinarily functional Basin faucets Targa Extraordinarily functional Beauty and simplicity mark the tendencies of the Targa faucet range. A proposal that can fill every corner of the bathroom
More informationUndertile Heating Mat. Instructions. CORGI Underfloor Heating - Quality, Flexibility, Safety 1
Undertile Heating Mat Instructions CORGI Underfloor Heating - Quality, Flexibility, Safety 1 It is vital that you read through these instructions fully before installing your CORGI undertile heating mat.
More informationFoil Heaters. Installation Manual: TECHNICAL HELPLINE
Installation Manual: Foil Heaters TECHNICAL HELPLINE 0345-345-2288 Complete and submit the warranty form online at www.warmup.co.uk IMPORTANT Read this manual before attempting to install your foil heater.
More informationInstallation And User Instructions
GB Installation And User Instructions Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter 1 Existing Floor Maximum load per m 2 Wooden Floors 100 W/m 2 Concrete Floors 150 W/m
More informationUSER MANUAL OF KL8300 SYSTEM
Carefully read all of the instructions before enjoying the spa. WARNING: Operating the system without water will cause severe damage. WARNING: SHOCK HAZARD! No user serviceable parts. Do not attempt to
More information>40 80 mm. Dishwasher EN Installation instructions. Appliance components >40. Recess for pipes >80. Front panel/decorative system.
Dishwasher EN Installation instructions Before installation, please read the safety precautions on the reverse side! Appliance components Recess for pipes >40 >80 >40 80 mm Front panel/decorative system
More informationV.lla Pro 5200 R - Cod. M0S Edizione 1H04
Pro 5200 R 3 12 10 7 8 1 11 2 6 9 5 4 13 V.lla Pro 5200 R - Cod. M0S05387 - Edizione 1H04 ENGLISH Vaporella Pro 5200 R R Pro 5200 R 1) Patented safety cap 2) 3-Position switch 3) Iron heating indicator
More informationINSTRUCTIONS AND MAINTENANCE MOD.MINI 4
INSTRUCTIONS AND MAINTENANCE MOD.MINI 4 Read these directions carefully before operating. Don t use the machine differently from the following description. 1. SPECIFICATIONS MODEL: MINI 4 POWER SUPPLY:
More information2 COOK TWO PLATE STOVE MODELS 184F, 185F, 186F & 187F
0063 0558CL1170 2 COOK TWO PLATE STOVE MODELS 184F, 185F, 186F & 187F IMPORTANT READ THESE INSTRUCTIONS CAREFULLY SO AS TO FAMILIARISE YOURSELF WITH THE APPLIANCE BEFORE USE. RETAIN THESE INSTRUCTIONS
More informationMidi Dehumidifi er IMPORTANT! KEEP FOR FUTURE REFERENCE. Instruction Manual. Please register your product on-line at
Instruction Manual Please register your product on-line at www.nscessity.co.uk Midi Dehumidifi er NSMDH-1608 www.nscessity.co.uk IMPORTANT! KEEP FOR FUTURE REFERENCE NSMDH-1608 Instructions 9.11.indd 2
More informationINSTRUCTION AND MAINTENANCE MANUAL DRYERS A5 - A6 - A7 - A7,5 - A8 - A9 - A10
Code 00773 04 Edit. 03/0 INSTRUCTION AND MAINTENANCE MANUAL DRYERS A5 - A6 - A7 - A7,5 - A8 - A9 - A0 READ THIS MANUAL CAREFULLY BEFORE CARRYING OUT ANY OPERATIONS ON THE DRYER. Cod. 00773 04 - Edition
More informationHT-2 / 9600 Series Control Contents
HT-2 / 9600 Series Control Contents Tools & Parts Tools Required Parts Required Error Messages 3 Flashing Dots Pressure or Flow Switch Not Activated Pressure or Flow Switch Activated Temperature Sensor
More informationSpa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)
Spa Touch Control Panel with 2000, 2100 controllers (Spa Owner s Manual insert) P.N. 7876B February 11, 2015 For Spas equipped with BP2000, BP2100 controllers and Spa Touch panel. Spa Touch Control Panel
More informationDOMESTIC STEAM GENERATOR Installation Instructions
DOMESTIC STEAM GENERATOR Installation Instructions Please read all of the instructions carefully before commencing installation or using the facility. Contents INTRODUCTION Page 2 TECHNICAL SPECIFICATION
More informationCOLOURS AND MATERIALS
Classic Collection COLOURS AND MATERIALS Shell white (A) crystal grey (I) silver white marble (1) cinnabar (2) azurite (3) midnight opal (5) Classic Collection Synthetic vertical slat panelling Headrest
More informationFlo~mate Mains Boost Pump Installation & Maintenance Instructions
~ Flo~mate Mains Boost Pump Installation & Maintenance Instructions Please leave this instruction booklet with the owner as it contains important guarantee, maintenance and safety information FOR POSITIVE
More informationUser manual Whirlpool
User manual Whirlpool Serial number: Foreword: This manual is general for all whirlpools in the BT-series. The user manual describes safety procedures, operating instructions and general maintenance. Please
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationInstallation Manual. Instrucciones de instalación y manual de usuario 1
Installation Manual Instrucciones de instalación y manual de usuario 1 Installation instructions and user manual V8 2 INDEX 1 GENERAL SAFETY WARNINGS... 4 2 OPERATING PRINCIPLE... 5 3 TECHNICAL FEATURES...
More informationINSTRUCTION AND MAINTENANCE MANUAL
Code 007758 0 Edit. 0/009 INSTRUCTION AND MAINTENANCE MANUAL DRYERS A A A A READ THIS MANUAL CAREFULLY BEFORE CARRYING OUT ANY OPERATIONS ON THE DRYER. Cod. 007758 0 - Edition 0/009 - CONTENTS PART A:
More informationE U R O V E N T CERTIFIED PERFORMANCE
Compact Horizontal Air-Air Heat Pump Model RTH-7K to 3K Ref.: Y-R719 7 Technical information E U R O V E N T CERTIFIED PERFORMANCE I S O 9 1 ER-8/1991 Clima Roca York S.L. is participating in the EUROVENT
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationSTEAM WALLPAPER STRIPPER MODEL HTW5
STEAM WALLPAPER STRIPPER MODEL HTW5 From Serial Number 75154 (110 Volt North America only) OWNERS MANUAL & OPERATING INSTRUCTIONS 2016/11 Hiretech Part # 007717 WARNING For safe operation of this machine,
More informationsaving water with roca
saving water with roca What are eco products? It can often be confusing to understand the different terminology used for eco products. Here, we clearly explain the types of product available and how they
More informationMSPA-MP METAPACK SERVICE MANUAL. Visual step-by-step guide to easily identify & correct technical problems! Gecko Electronics Inc.
MSPA-MP METAPACK SERVICE MANUAL Gecko Electronics Inc. Visual step-by-step guide to easily identify & correct technical problems! Table of Contents Power & Ground Check Tools and Parts 3 Electrical Wiring
More informationInstructions for installation and use RE/I. Industrial electric heater for swimming pool
Instructions for installation and use RE/I Industrial electric heater for swimming pool Réf. : N.D.010.A.EN Ver. 06-2010 1. Installation... 2 1.1 General... 2 1.1.1 Precautions... 2 1.1.2 General terms
More informationINSTRUCTION AND MAINTENANCE MANUAL DRYERS A 11 - A 12 - A 13 - A 14 (R410A)
Code 007806 0 Edit. 0/04 INSTRUCTION AND MAINTENANCE MANUAL DRYERS A - A - A - A 4 (R40A) READ THIS MANUAL CAREFULLY BEFORE CARRYING OUT ANY OPERATIONS ON THE DRYER. Cod. 007806 0 - Edition 0/04 - CONTENTS
More informationEL1000 Mach 3 Tech Sheet Balboa Instruments
EL000 Mach Tech Sheet Balboa Instruments System PN 55068-04 System Model # EP-EL000M-DCAH Software Version # EPN # 8 Base PCBA PN 5487-04 PCB EL000 PN 95 Rev B or C HEX File 0004 Base Panels ML400 PN 5684
More informationUser Instruction Manual
User Instruction Manual Mulled Wine Heater Please read and keep these instructions You will need: -32 amp plug socket -Temperature thermometer These instructions cover the Mulled Wine Heater Mulled Wine
More informationIndex I. INSTALLATION DIAGRAM... WIRING DIAGRAMS...
Index I. INSTALLATION DIAGRAM... 4 II. III. WIRING DIAGRAMS...... 1. Wiring diagram AC 3-N-400 50/60 Hz... 2. Wiring diagram AC 3-230 50/60 Hz...... 3. Wiring diagram AC 230 50/60 Hz... 4. Series 30 electrical
More informationHeavy Duty Pressure Washer 150
Heavy Duty Pressure Washer 150 7902 WARNING: Do not use the appliance without reading this instruction sheet Hozelock Ltd. Midpoint Park Birmingham, B76 1AB. England Tel: +44 (0) 121 313 1122 info@hozelock.com
More informationWET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS
WET & DRY GARAGE VAC 20L CAPACITY 1.5M SUCTION HOSE STAINLESS STEEL TANK ON BOARD ACCESSORY STORAGE 1250 WATT MOTOR KP702 Table of Contents 20L WET & DRY GARAGE VAC Know Your Product...1 Vacuum Safety
More informationCondensate removal pumps
Condensate removal pumps World Premiere SICCOM S.A.S was founded in 1979 and specialises in level and proximity sensors, bimetal heat protection and condensate removal pumps. SICCOM's expertise means customers
More informationDehumidification and ventilation for residential, industrial radiant systems and swimming pools
Dehumidification and ventilation for residential, industrial radiant systems and swimming pools HiDew is proud to present a complete range of dehumidifiers for radiant cooling systems and high performance
More informationWC2 & WC3 Installation & Maintenance Instructions
WC2 & WC3 Installation & Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information WC3 shown WC2 WC3 IMPORTANT
More informationCERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE
Electric underfloor heating Simple to install Cheap to install Simple to regulate Safe to use Maintenance free CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE WHY CHOOSE HEATCOM? Heatcom is a leading
More informationINSTALLATION AND USER MANUAL
INSTALLATION AND USER MANUAL HYDROMASSAGE CABIN SILVER DIAMOND LUX www.kerra.pl INSTALLATION AND USER MANUAL HYDROMASSAGE CABIN SILVER DIAMOND LUX Thank you for purchasing our product. Please read this
More informationThe Classeq under counter range
Installation & Operators Manual The under counter range Part number 902.0011 Revision C Effective date January 2010 Language English Glasswashers Eco 1 Eco 2 Eco 3 Duo 2 Duo 3 Dishwasher Hydro 500 Hydro
More informationElectric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada
Electric Floor Warming Systems Installation and Operation Instructions Mat Heating Systems and Cable Heating Systems UL Listed for USA and Canada Thank you for your purchase of a Warming Systems electric
More informationAquapeutics GENERAL INSTALLATION GUIDE. Toll Free Customer Service line 1 (800)
Aquapeutics GENERAL INSTALLATION GUIDE Toll Free Customer Service line 1 (800) 290-6812 Thank you for choosing an Aquapeutics product. Please read the following guide in its entirety before assembling
More informationshower panel specification manual 2008
Uniclass L72107 CI/SfB (74.26) X EPIC H123 shower panel specification manual 2008 HORNE ENGINEERING Ltd tel +44 (0)1505 321455 email sales@horne.co.uk web www.horne.co.uk shower panel specification manual
More informationCascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions
Cascade Premier and Elite Premier Bathing Systems with Aqua-Aire Installation / Assembly Instructions Premier Elite Premier PENNER PATIENT CARE, INC Box 523 / 102 Grant St. Aurora, NE 68818 360745P Revision
More informationHigh Pressure Washer 130
High Pressure Washer 130 7901 WARNING: Do not use the appliance without reading this instruction sheet ORIGINAL INSTRUCTIONS Hozelock Ltd. Midpoint Park Birmingham, B76 1AB. England Tel: +44 (0) 121 313
More informationOperating manual. Pellet boiler. Orlan Pellet ISO 9001
Operating manual Pellet boiler Orlan Pellet ISO 9001 Contens 1. Boiler s use...................................................................... 3 2. Boiler s way of working...........................................................