INDIVIDUAL HEATING. Installation Manual e Skirting Heating Classic. Skirting Heating Delta. HEATING. COOLING. COMFORT.

Size: px
Start display at page:

Download "INDIVIDUAL HEATING. Installation Manual e Skirting Heating Classic. Skirting Heating Delta. HEATING. COOLING. COMFORT."

Transcription

1 INDIVIDUAL HEATING Skirting Heating Classic. Skirting Heating Delta. Installation Delta HEATING. COOLING. COMFORT. Classic Installation Manual e22111

2 Page 2 Table of Contents INDIVIDUAL HEATING 1 Safety information Regulations Guarantee conditions Weather resistance of the pre-insulated Variomodular pipe 16x2/Alu Heating elements Skirting heating types Skirting heating types with metal cladding - Delta skirting heating system Skirting heating types for wooden cladding (provided by the customer) - Classic skirting heating system Skirting heating types for wooden cladding (provided by the customer) - Skirting heating system Classic Pipes General Connection spacing from the wall Maximum skirting heating length per heating circuit Manifold system with the pre-insulated Variomodular pipe 16x2/Alu pipe system e.g. with copper pipe Fitting the brackets Bracket components, designations Preparation Fastening the brackets Fitting the heating elements Inserting the heating elements Securing the heating elements Hydraulic connection of the heating elements Manifold system pipe system Cladding Delta cladding Classic cladding Leak-tightness test & commissioning Drilling templates for the brackets... 17

3 Installation manual 1 Safety information Page 3 1 Safety information 1.1 Regulations Observe the applicable local regulations and standards for electrical and heating installation. 1.2 Guarantee conditions If the heating system is installed or commissioned incorrectly, all claims on the basis of the manufacturer's warranty and guarantee become void. 1.3 Weather resistance of the pre-insulated Variomodular pipe 16x2/Alu0.25 The Variomodular pipe is only weather-resistant to a limited extent, and must be shielded from direct sunlight. The Variomodular pipe should not be stored outdoors. The interaction of the air's oxygen with UV rays damages the pipes. Normal temporary storage on the construction site for a few days is permissible. 1.4 Heating elements The heating elements are delivered packaged in boxes with a length of 2.5 m. They must be protected against damage or unintentional bending of the louvres mm 40 mm 40 mm 56 mm 78 mm ø 18 mm 0,5 mm Copper pipe wall thickness Standard heating element 2500 mm 40 mm 40 mm 35 mm 78 mm ø 18 mm 0,5 mm Copper pipe wall thickness Mini heating element

4 Page 4 2. Skirting heating types INDIVIDUAL HEATING 2. Skirting heating types 2.1 Skirting heating types with metal cladding - Delta skirting heating system 65 mm 87 mm 87 mm 42 mm 1 mm 195 mm 195 mm 195 mm -40 mm mm mm mm Delta skirting heating system mini Delta skirting heating system Ia Delta skirting heating system IIa Delta skirting heating system IIIa 2.2 Skirting heating types for wooden cladding (provided by the customer) - Classic skirting heating system a 44 mm a 65 mm a 88 mm a 88 mm b b b b c 1 mm c 200 mm c 200 mm c 200 mm s d s d s d s d Skirting heating system mini Classic Skirting heating system Ia Classic Skirting heating system IIa Classic Skirting heating system IIIa Classic a mm + s b mm c mm d... min. to max. 40 mm s... min. 15 mm (e.g. wooden multilayer board) a mm + s b mm c mm d... min. 40 to max. 50 mm s... min. 15 mm (e.g. wooden multilayer board) a mm + s b mm c mm d... min. 40 to max. 50 mm s... min. 15 mm (e.g. wooden multilayer board) a mm + s b mm c mm d... min. 40 to max. 50 mm s... min. 15 mm (e.g. wooden multilayer board) 2.3 Skirting heating types for wooden cladding (provided by the customer) - Skirting heating system Classic d If the shaft height changes (= lower edge of the heating element to the upper edge of the front cladding) an additional fastening must be provided to secure the cladding (provided by the customer). 120 mm 170 mm 170 mm 160 mm 200 mm 160 mm 200 mm 160 mm Schachthöhe Shaft height 200 mm d 40 mm 40 mm 40 mm Change in shaft height Skirting heating system IVa Classic with wooden brackets Skirting heating system Va Classic with wooden brackets Skirting heating system VIa Classic with wooden brackets

5 Installation manual 3. Pipes Page 5 3. Pipes 3.1 General Socket Skirting heating systems are installed in the manifold system with preinsulated Variomodular pipes or in the 2-pipe system with copper pipes, for example. When planning electric sockets, ensure that they are located above the skirting heating. 3.2 Connection spacing from the wall Skirting heating system mini Finished wall Skirting heating system Ia Finished wall Flow Length entered in the plan Reciprocal connection Return Flow Return 20 mm Length entered in the plan Reciprocal connection 31 mm Skirting heating system IIa Skirting heating system IIIa Finished wall Finished wall Flow Return Flow Return Length entered in the plan Reciprocal connection 42 mm -50 mm 42 mm Length entered in the plan Connection on one side To prevent damage to the heating elements and cladding, they should not be fitted to the painted walls until the flooring is completed. The supply pipes are installed in accordance with the connection spacing shown above. 3.3 Maximum skirting heating length per heating circuit Mini skirting heating, Ia and IIa: max. 7.5 m per heating circuit Skirting heating IIIa: max. 5.0 m per heating circuit Max. length 5.0 m Max. length 7.5 m e.g. Skirting heating system mini, manifold system e.g. Skirting heating system IIIa, 2-pipe system

6 C C Page 6 2. Skirting heating types INDIVIDUAL HEATING 3.4 Manifold system with the pre-insulated Variomodular pipe 16x2/Alu0.25 For installations with manifold systems, first lay the pre-insulated Variomodular pipes from the manifold to the skirting heating and back, and then connect them to the manifold via a screw fitting. There must not be any kinks in Variomodular pipes when laying them. The Variomodular pipe should be routed endlessly (i.e. without additional connection points) from the manifold to the skirting heating. The pipe is positioned near the skirting heating with the installation bracket. Electronic room thermostats and servomotors are used to control the room temperature. Pre-insulated Variomodular pipe 16 x 2/Alu 0.25 Kitchen Feed Hall e.g. PIANO H Anteroom RT Distribution manifold RT Living room WC Elbow union FFL Laying example with Variotherm distribution manifold Protective pipe Pre-insulated Variomodular pipe Installation bracket Inner flexible spring Elbow union mini Ia Pre-insulated Variomodular pipe 16 x 2/Alu 0.25 to manifold IIa Copper bend 5001A ø 18 & 5002A ø 18 IIIa

7 Installation manual 2. Skirting heating types Page 7 VERTEILEN und REGELN "DISTRIBUTION and CONTROL" Montage Planung 20 C Details regarding the system and heating circuit pipes and the room temperature control are provided in the "DISTRIBUTION and CONTROL" planning and installation manual C Montageanleitung & Planungshandbuch pipe system e.g. with copper pipe Feed Cu ø 18 Hall Kitchen Cu ø 18 Anteroom Cu ø 18 Cu ø 22 Cu ø 18 WC Rising line From boiler house or boiler Cu ø 22 For installation in the 2-pipe system, flow valves with an integrated deaeration system are used to control the room temperature. The return valves are used to shut off and set the water quantity (hydraulic compensation) Living room Cu ø 18 Laying example with 2-pipe system Ia mini Return valve IIa Copper bend 5001A ø 18 & 5002A ø 18 IIIa Thermostat head

8 Page 8 4. Fitting the brackets INDIVIDUAL HEATING 4. Fitting the brackets 4.1 Bracket components, designations The brackets for the Classic and Delta skirting heating systems are identical. For the Classic skirting heating system, a mounting plate and a mounting base are supplied for each bracket, to allow the cladding provided by the customer to be attached to the bracket d 3d 3b 3b 3 3a 4 3c 4 Components for Classic & Delta skirting heating systems (parts in red frame for Classic only) Rounded head screws 5x45 mm (3x) 2... Dowels U8 (3x) 3... Bracket (1x) 3a... Catch 3b... Bearing (heating element) 3c... Spring 3d... Screw slot 4... Clip (mini, Ia: 1x; IIa + IIIa: 2x 5... Upper mounting base (1x) 6... Front mounting base (1x) 7... Countersunk head screws 3x16 mm (8x) 4.2 Preparation Mark using the bracket or drilling templates (see Chapter 9) approx. 750 mm 200 mm Determine the height of the bracket. *Distance from the finished floor to the lower edge of the bracket (= lower edge of cladding): mini: -40 mm Ia, IIa, IIIa: mm * 750mm Make further markings approx. every 750 mm using a spirit level. Drill holes (if necessary) 4.3 Fastening the brackets Use spacers to smooth uneven parts of the wall. The upper and front edge of the bracket should be aligned (test with bar). Screw the lower and one of the two upper screws into the positions marked previously, but not fully (allow space of approx. 5 mm). 4. Fit the bracket to the screws Fit the missing screw, align the bracket and fasten (tighten all screws).

9 Installation manual 5. Fitting the heating elements Page 9 5. Fitting the heating elements 5.1 Inserting the heating elements Lay the heating elements parallel to the wall and push the aluminium plates on the brackets to one side with an open-end wrench (size 21), for example. Insert the heating element The heating elements are cut to length according to the diagram using pipe cutters. Sections are soldered to one another or pressfit (use approval for the Viega Profipress system > support sleeves!) Ensure that the installation position of the heating element is correct in accordance with the prescribed types (see Chap. 3). 5.2 Securing the heating elements Secure the heating element using the clips The clip of the respective type is pushed down at the points marked with an arrow, and then latched into position using the thumb. The clip can be removed easily using a multigrip pliers. mini Ia IIa+IIIa Clips for securing the skirting heating

10 Montage Planung C C VERTEILEN und REGELN Montageanleitung & Planungshandbuch Page Hydraulic connection of the heating elements INDIVIDUAL HEATING 6. Hydraulic connection of the heating elements 6.1 Manifold system Cutting to length, calibrating and bevelling the pre-insulated Variomodular pipe The Variotherm pipe cutting pliers is used to cut the pipe to length. Caution! The pipe must be cut at a right angle. Rotate the calibration tool into the pipe to the stop angle to calibrate and bevel the end of the pipe. Visually check that the face of the pipe is smooth, clean and free of Pipe cutting pliers 11.6/16 chips. Calibration and bevelling tool Feed to flow and return a 2b Push union nut (2b) loosely over the pre-insulated Variomodular pipe (1). Insert the support up to the stop while turning it slightly (do not hammer in). Insert the Variomodular pipe with the support into the union nut up to the stop, and tighten the screw fitting in this position. Push the assembled clamping screw fitting (5) loosely over the copper pipe. Insert the support sleeve (4) into the copper pipe. Important: Push the copper pipe into the bracket (3) until it stops and tighten the screw fitting in this position. 1 (1) Pre-insulated Variomodular pipe (2) 3/4 EUROx16 clamping screw fitting (3) 90 bracket 3/4 EURO (4) Support sleeve 18 x 17 mm (5) 3/4 EUROxCu18 clamping screw fitting (6) Heating element Support sleeve 18 x 17 mm Clamping screw fitting 3/4 EUROxCu18 Clamping screw fitting 3/4 EUROx16 Deaeration Deaeration is performed by flushing and the deaerators installed on the distribution manifold. "DISTRIBUTION and CONTROL" Details regarding the system and heating circuit pipes and the room temperature control are provided in the "DISTRIBUTION and CONTROL" planning and installation manual pipe system In the 2-pipe system, the skirting heating is piped in accordance with the laying diagram using copper pipes, for example. The flow valve is installed with integrated deaeration in the flow side and the return valve is installed in the return side.

11 Installation manual 6. Hydraulic connection of the heating elements Page 11 Soldering the copper piping Before soldering, prepare a cover to protect the floor and wall from flames. Clean the pipes and fittings at the solder contact points with a cleaning cloth and inner brush. Apply solder paste evenly to one part. Join the two contact points and solder them. It is important that the soldering point is kept clear of dirt particles such as masonry dust etc. Tip for piping: If necessary (old building with finished floors etc.), additional uninsulated pipes to max. 18 mm external diameter can also be held in the brackets. Typ Ia Typ IIa Typ IIIa Deaeration The individual skirting heating systems are deaerated via the flow valves with integrated manual deaeration systems. The deaeration elbow is inserted in the return for valves without integrated deaeration systems. Deaeration elbow Flow valve The flow valve with integrated deaeration is available in left, right or continuous versions. On delivery, there is a protective plastic cap on the valve spindle. This allows the valve to be opened or closed without a valve head. Before mounting the valve head or the handwheel, the protective plastic cap is removed. Duct Left corner Right corner Valve heads for flow valves Thermostat head Servomotor Handwheel Thermostat head with remote sensor Extension for thermostat head 20 mm, from a cladding thickness of 10 mm for IIa + IIIa Classic

12 Page Hydraulic connection of the heating elements INDIVIDUAL HEATING Feed to flow Push the assembled clamping screw fitting (2) loosely over the copper pipe, insert the support sleeve (4) into the copper pipe. Caution! The pipe must be cut at a right angle. Important: Push the copper pipe into the valve until it stops and tighten the screw fitting in this position. 2 Cu15/18 (1) e.g Cu pipe ø 18 mm (2) 3/4 EUROxCu18 clamping screw fitting (3) Left corner flow valve (4) Support sleeve 18 x 17 mm (5) Heating element 1 Support sleeve 18 x 17 mm Clamping screw fitting 3/4 EUROxCu18 Flow valve characteristic curve DN DN (1/2 ), ( 1 /2"), cv kv-wert value 0,49 0,49 (applies (gilt für to Thermostatkopf) thermostatic head) Sample calculation Pressure Druckverlust loss p p [kpa] [kpa] 0,5 5 0,3 3 0,2 2 0, Massenstrom flow m [kg/h] m [kg/h] Pressure Druckverlust loss p p [mbar] [mbar] Pressure Druckverlust loss p p [mmwc] [mmws] Regeldifferenz xp Control difference xp 2 K Sample calculation 1: Required: Pressure loss for 1/2 at 2 K control difference Given: Heat flow Q = 1450 W, Temperature spread t = 10 K (55/45 C) Solution: Mass flow m = Q/(c t) = 1450/( ) = 125 kg/h Pressure loss from diagram p = 65 mbar / 650 mmwc (0.65 mwc) / 6500 Pa

13 Installation manual 6. Hydraulic connection of the heating elements Page 13 Return valve The return valve is used for hydraulic compensation and as a shut-off valve if the heating elements have to be dismantled (e.g. for painting). The valve spindle is under the protective cap. The return valve can be closed by rotating it. Duct Corner Feed to return Cu15/18 (1) e.g Cu pipe ø 18 mm (2) 3/4 EUROxCu18 clamping screw fitting (3) Corner return valve (4) Support sleeve 18 x 17 mm (5) Heating element 1 Push the assembled clamping screw fitting (2) loosely over the copper pipe, insert the support sleeve (4) into the copper pipe. Caution! The pipe must be cut at a right angle. Important: Push the copper pipe into the valve until it stops and tighten the screw fitting in this position. Support sleeve 18 x 17 mm Clamping screw fitting 3/4 EUROxCu18 Return valve characteristic curve Einstell-Umdrehungen Configuration rotations [U] [U] 0,25 0,75 0,5 1,75 1,5 1, ,5 3 3,5 max. Max. delivery condition open Sample calculation 2 Pressure Druckverlust loss p [kpa] 1 0, ,3 3 0,2 2 0, Pressure Druckverlust loss p [mbar] Pressure Druckverlust loss p [mmwc] [mmws] Massenstrom flow m [kg/h] m [kg/h] Sample calculation 2: Required: Valve opening (rotations) at a pressure loss via the return valve of p = mbar (0. mwc, 00 Pa) Given: Heat flow Q = 1450 W, Temperature spread t = 10 K (55/45 C) Solution: Mass flow m = 1450/( ) = 125 kg/h > Open the return valve 1.25 rotations.

14 Page Cladding INDIVIDUAL HEATING 7. Cladding If the required skirting heating cladding is not mounted immediately, protect the mounted heating elements using their packaging boxes, for example (cut slits in the box, pass the bracket catches through). This effectively protects the heating elements from damage. 7.1 Delta cladding Fit the Delta at the bottom near the tension spring and click it into place at the top. Delta cladding which has been clicked into place. If uneven walls cause problems when snapping the upper edge into place, loosen the upper bracket screws. After locking the cladding into place, the screws can then be tightened again through the upper front hot air slit opening To remove the cladding, first pull it out at the bottom and lift it out upwards. Connections The connecting elements are clipped in, inner corners, outer corners and the end caps on the left and right are fastened subsequently using the enclosed screws to the front cladding (do not forget to drill). Inside corner 90 Outside corner 90 Connecting elements End cap left End cap right The formed parts are attached with the supplied screws. Use the Variotherm paint pen to paint the screw heads after mounting. Round hole punch For the flow valves, punch a hole into the Delta cladding in the axis of the valve head using the appropriate round hole punch. The thermostat head will later protrude through this hole. Hole diameter required: ø 40 mm for mini skirting heating system, ø 55 mm for Ia, IIa + IIIa, and valves with servomotors Example: Delta mini skirting heating system

15 Installation manual 7. Cladding Page Classic cladding *... Comply with spacing per Page 5 Schachthöhe Shaft height d* Schachthöhe Shaft height d* Please note the dimensions of the cladding on page 5. If the wooden skirting is mounted further from the floor (e.g. due to wall-mounted pipes), you must still comply with the air vent spacing (extend cladding further down) For cladding of the Classic skirting heating provided by the customer, each bracket includes a mounting plate and mounting base with fastening screws (see also Chap. 5.1). Virtually any wood is suitable as wooden cladding. It should be torsion free and dry (e.g. 3-layer board). Push the mounting base into the bracket and transfer the outline to the upper cladding. Screw the mounting base onto the upper cladding The upper cladding can now be pushed into place. For the front cladding, the mounting plate is secured after adaptation to the brackets Attach the front cladding to the bottom spring and click it into the catch. Simple mounting brackets are used for end connections. Drill a hole in the cladding in the axis of the valve head for the flow valves.

16 Page Leak-tightness test & commissioning INDIVIDUAL HEATING 8. Leak-tightness test & commissioning Construction project: Building owner/ Occupant: Client: Heating installation technician: Architect: Other: Leak-tightness test The Variotherm skirting heating system circuits are to be tested for leak-tightness using a water pressure test after they have been laid. The test pressure should be twice the operating pressure (at least 6 bar). If there is a risk of freezing, appropriate measures should be taken, e.g. use of antifreeze and controlling the building s temperature. > Skirting heating incl. cladding, connection and piping completed on: > Pressure test started on: > Pressure test finished on: > The system water was treated (e.g. per ÖNORM H5195-1) Yes No > Antifreeze was added to the system water Yes No > Heating started on: Approval: Building owner/occupant/client Construction management/architect Heating installation technician Commissioning The flow and return valves or the heating circuit shut-offs on the manifold must be opened. The entire system is to be deaerated thoroughly. The circulation pump may be switched on after deaeration. After commissioning, the Variotherm skirting heating system can be considered maintenance-free. (Subject to technical modifications without notice.)

17 Installation manual 9. Drilling templates for the brackets Page Drilling templates for the brackets 28 17,5 mini 115 FFL min. max. 40 FFL

18 Page Leak-tightness test & commissioning INDIVIDUAL HEATING 28 min. 40 max Ia FFL FFL

19 Installation manual 8. Leak-tightness test & commissioning Page min. 40 max IIa + IIIa FFL FFL

20 HEATING. COOLING. COMFORT. Variotherm has been developing, producing and selling innovative, ecological and economical heating and cooling systems since Your Variotherm partner VARIOTHERM HEIZSYSTEME GMBH GÜNSELSDORFER STRASSE 3A 2544 LEOBERSDORF AUSTRIA Phone: +43 [0] Fax: +43 [0] All rights pertaining to distribution and translation, in whole or in part, including film, radio, television, video recording, Internet, photocopying and reprinting, are reserved.

INDIVIDUAL HEATING. Design manual e Classic, Delta & Beta skirting heating systems. Planning.

INDIVIDUAL HEATING. Design manual e Classic, Delta & Beta skirting heating systems. Planning. www.variotherm.at INDIVIDUAL HEATING Classic, Delta & Beta skirting heating systems Planning Classic Delta Beta Design manual e237 Page 2 Table of Contents INDIVIDUAL HEATING. Principles... 3. What does

More information

SHSKIRTING HEATING. INSTALLATION.

SHSKIRTING HEATING. INSTALLATION. SHSKIRTING HEATING. INSTALLATION. Classic. Beta. Delta. www.variotherm.com VMONT2 e21617 TABLE OF CONTENTS 1. Safety information... 3 1.1 Generel... 3 1.2 Guarantee conditions... 3 1.3 Storage of the heating

More information

SHTH SKIRTING HEATING. TRENCH HEATING. The Classic, Delta and Beta skirting heating systems. Trench heating systems.

SHTH SKIRTING HEATING. TRENCH HEATING. The Classic, Delta and Beta skirting heating systems. Trench heating systems. SHTH SKIRTING HEATING. TRENCH HEATING. The Classic, Delta and Beta skirting heating systems. Trench heating systems. www.variotherm.com VIDEO Wonderfully discreet. Cosiness you can feel. The energy saving,

More information

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise. Flush Individual Room Control for Floor Heating Systems To be precise. Contents Page Multibox K, Multibox RTL and Multibox K-RTL Description Construction Application 4 Temperature Setting 4 Function Article

More information

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22 HERZ TS-3000 HERZ-3000 Connection system for radiators Thermostatic valve and shut-off return valve Standard sheet for 3691-3694 3791 3794 Issue 0702 G 3/4 Dimensions in mm 1 3002 31 Connection nipples

More information

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,

More information

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function HERZ-3000 Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function Standard Sheet for 3791 3792 Edition 1000 (0999) Dimensions in mm 1 3001 01 Cone sleeve 1 3002 01 Connection

More information

Installation Instructions

Installation Instructions Installation Instructions KFN 9855 ide en - CA Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien HERZ-Thermostatic and Return Valves Standard Sheet for DE LUXE Edition 1000 (0999) This series consists of HERZ radiator thermostats, HERZ-TS-90 thermostatic valves and HERZ return valves. These components

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off Multibox 4 Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off IMI HEIMEIER / Floor Heating Control / Multibox 4 Multibox 4 RTL and K-RTL and K-RTL is

More information

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Connection set. Radiator connection set for thermostatic and manual operation Ø 12 Connection set Radiator connection set for thermostatic and manual operation Data sheet for 1 7650 00 Issue 0405 Control valves Connection pipe Ø 12 L L = 600 1 7650 00 L = 1000 1 7650 01 Bypass bodies

More information

Control valves for floor heating systems. Floor Heating Manifolds

Control valves for floor heating systems. Floor Heating Manifolds Control valves for floor heating systems Floor Heating Manifolds IMI HEIMEIER / Floor Heating Control / Control valves for floor heating systems Control valves for floor heating systems Supply control

More information

CIRCO 6 Solar Circulation Unit

CIRCO 6 Solar Circulation Unit TECHNICAL INFORMATION / INSTALLATION INSTRUCTIONS CIRCO Solar Circulation Unit CIRCO Solar Circulation Unit in combination with the intelligent SUNGO controllers, it is the safe and reliable heart of a

More information

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Multibox. Floor Heating Controller Flush individual room control for floor heating systems Multibox Floor Heating Controller Flush individual room control for floor heating systems IMI HEIMEIER / Floor Heating Control / Multibox Multibox K, RTL and K-RTL Multibox K, RTL and K-RTL is used for

More information

Mikrotherm. Manual Radiator Valves With presetting

Mikrotherm. Manual Radiator Valves With presetting Mikrotherm Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm Mikrotherm The Mikrotherm manual radiator valve is used in warm water pump heating systems,

More information

Standard. thermostatic valve body without presetting

Standard. thermostatic valve body without presetting Standard thermostatic valve body without presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control EnGInEErInG advantage The standard thermostatic valve bodies are used in two-pipe

More information

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation Standard Sheet for 6823/ 6824 Edition 1000 (0999) 6823 6824 Special Models 1

More information

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting V-exact II Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / V-exact II V-exact II V-exact II thermostatic valve

More information

INVERTER SPLIT - TYPE

INVERTER SPLIT - TYPE INVERTER SPLIT - TYPE ISSUE No 2 DATE 04/09/08 P/No 2020323A2868 CONTENTS SAFETY PRECAUTIONS Warning 2 Operating temperature 2 BEFORE INSTALLATION Tools needed for installation 3 Items required for installing

More information

Installation Instructions

Installation Instructions Installation Instructions For the 18" Built-In Dishwasher Sears, Roebuck and Co. Sears Canada, Inc. Hoffman Estates, IL 60179 U.S.A. Toronto, Ontario, Canada M5B 2B8 154435201 Before You Begin DO NOT INSTALL

More information

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold Dynalux Floor Heating Manifolds Underfl oor heating circuit manifold IMI HEIMEIER / Floor Heating Control / Dynalux Dynalux Dynalux adjusts the flow rate in the individual heating circuits directly in

More information

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility Regulux Return Lockshield Radiator lockshield with consistent presetting and drain-off facility IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Regulux Regulux The Regulux is used in warm water pump

More information

Refrigerator BRFB1920SS BRFB1900FBI BRFB1920FBI

Refrigerator BRFB1920SS BRFB1900FBI BRFB1920FBI Refrigerator BRFB1920SS BRFB1900FBI BRFB1920FBI Table of Contents Symbols and Their Meanings... 3 Product weight... 5 Load bearing capacity of the doors... 5 Climate class... 5 Product Information:...

More information

Flush individual room control for floor heating systems

Flush individual room control for floor heating systems Multibox Flush individual room control for floor heating systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGiNEERiNG ADVANTAGE Multibox is used for decentralized control

More information

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge Regulux Description Separate presetting cone for consistent

More information

Installation & Maintenance Data IM Contents

Installation & Maintenance Data IM Contents Installation & Maintenance Data IM 254-4 Group: Fan Coil Part Number: 107133000 Date: June 1999 SeasonMaker HiLine Fan-coil Units Type KZZ Contents Inspection..................................... 2 Riser

More information

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control Table of Contents Congratulations on purchasing your new Casablanca ceiling fan! It will provide comfort and performance in your home or office for many years. This installation and operation manual contains

More information

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1968 CHEVROLET IMPALA

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1968 CHEVROLET IMPALA specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1968 CHEVROLET IMPALA CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect

More information

Installation Instructions

Installation Instructions Aluminum Blinds Installation Instructions Echelon, Traditions & Integra Aluminum Blinds 2 Metro Aluminum Blinds *Click on any page to return to the Table of Contents* Echelon, Traditions & Integra Aluminum

More information

SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80

SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80 Installation & Maintenance Data IM 255-6 SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80 Group: Fan coil Part Number: # 106332400 Date: August 2000 Table of Contents Inspection............................................................................

More information

HEATING. COOLING. COMFORT. For a cosy home.

HEATING. COOLING. COMFORT. For a cosy home. HEATING. COOLING. COMFORT. For a cosy home. www.variotherm.com VIDEO VIDEO THE VARIOTHERM WORLD AMAZING COMFORT. WITH ATTRACTIVE SAVINGS. Variotherm s floor heating systems, skirting heating systems, trench

More information

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher Table of Contents www.casablancafanco.com To register your fan, please visit: www.casablancafanco.com/register What to Expect with Your Installation Save your receipt for proof of purchase. Ceiling Bracket??

More information

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control

Table of Contents What to Expect with Your Installation. Tools Needed. Wall Control Table of Contents Congratulations on purchasing your new Casablanca ceiling fan! It will provide comfort and performance in your home or office for many years. This installation and operation manual contains

More information

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod.

Table of Contents.   What to Expect with. Mounting Options. Tools Needed. Preparation. Wiring. Downrod. Table of Contents www.casablancafanco.com What to Expect with Your Installation Congratulations on purchasing your new Casablanca ceiling fan! It will provide comfort and performance in your home or office

More information

SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12

SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12 Installation & Maintenance Data IM 168-5 SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12 Group: Fan coil Part Number: # 107132900 Date: June 1999 Table of Contents Inspection............................................................................

More information

Dishwasher. Installation manual DW60M9990AP

Dishwasher. Installation manual DW60M9990AP Dishwasher manual DW60M9990AP DW9000M_DD68-00197B-00_EN.indd 1 6/1/2017 4:34:14 PM Contents Contents 3 What s included 3 requirements 7 Dimensions and specifications 9 Step-by-step installation 11 2 English

More information

Thermostatic valve bodies

Thermostatic valve bodies Thermostatic valve bodies for all thermostatic heads and actuators Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE ThermosTaTic valve bodies Table of contents

More information

Installation Instructions

Installation Instructions GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover

More information

Regulux. Radiator lockshield with drain-off facility. To be precise.

Regulux. Radiator lockshield with drain-off facility. To be precise. Radiator lockshield with drain-off facility To be precise. Description Assembly Regulux Closing cap Thrust piece HEIMEIER radiator lockshield for shutting off, presetting, draining off and filling. Separate

More information

Technical information Installation instructions. Modul-plus (F21-52) High performance calorifiers

Technical information Installation instructions. Modul-plus (F21-52) High performance calorifiers Technical information Installation instructions Modul-plus (F21-52) High performance calorifiers These instructions apply to the following types: 5/6-Modul-plus F (21) 5/6-Modul-plus F (31) 5/6-Modul-plus

More information

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting Calypso exact Thermostatic Radiator Valves With stepless precision presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Calypso exact Calypso exact thermostatic valve bodies are

More information

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and operation instructions Solar stations SolarBloC

More information

CEILING FAN OWNER S MANUAL

CEILING FAN OWNER S MANUAL Style that revolves around you. CEILING FAN OWNER S MANUAL Total fan weight *53 lbs. WEXFORD 11/05 WARNING: Read and follow these instructions carefully and be mindful of all warnings shown throughout.

More information

FIREPLACE INSTALLATION

FIREPLACE INSTALLATION CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace

More information

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting Standard Thermostatic Radiator Valves Thermostatic valve body without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard Standard The Standard thermostatic valve bodies are used

More information

Air Conditioner. user installation & manual manual. imagine the possibilities

Air Conditioner. user installation & manual manual. imagine the possibilities ARFSSSBWK Series ARFSSSCUR AJ JNADCH Series Air Conditioner user installation & manual manual This manual is made with 100% recycled paper. imagine the possibilities Thank you for purchasing this Samsung

More information

Moisture inside the drum is due to final testing.

Moisture inside the drum is due to final testing. Safety instructions Scope of delivery depending on model Moisture inside the drum is due to final testing. Removing the transport braces Water connection depending on model The washing machine is heavy

More information

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems E-Z Valve Thermostatic valves with radiator connection systems For single and two-pipe heating systems IMI HEIMEIER / Thermostatic heads and Radiator valves / E-Z Valve E-Z Valve E-Z Valve with immersion

More information

INSTRUCTION MANUAL with Replacement Parts

INSTRUCTION MANUAL with Replacement Parts INSTRUCTION MANUAL with Replacement Parts MODEL FD500 FOOD WASTE DISPOSERS (INCLUDES MOTOR PARTS) ML-18978 A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 FORM 11394 Rev. G (10-98)

More information

Mounting and Operating Instructions EB 2231 EN

Mounting and Operating Instructions EB 2231 EN Self-operated Regulators Thermostats Type 223 and Type 2232 Bulb Sensors Type 2233, Type 2234, and Type 2235 Air Sensors Type 223 with bulb sensor Type 2232 with bulb sensor (separate) Type 2233 with air

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be Installation Instructions Built-In Dishwasher If you have questions, call 800.GE.CARES (800.432.2737) or visit our website at: www.ge.com BEFORE YOU BEGIN Read these instructions completely and carefully.

More information

Installation Instructions

Installation Instructions Installation Instructions Built-In Dishwasher If you have questions, call 800-GECARES or visit our website at: www.geappliances.com BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT

More information

Right-hand connection. 1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

Right-hand connection. 1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm Hose and cable lengths depending on model Scope of delivery depending on model AquaäStop AquaäSecure or Left-hand connection ~ 100 cm ~ 145 cm ~ 145 cm ~ 95 cm Moisture inside the drum is due to final

More information

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS VIKING 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 IMPORTANT - PLEASE READ AND FOLLOW Before beginning - please read these instructions

More information

Übersetzung. Installation instructions Page 10. Multi-temperature wine cabinet UWT 1672 / UWK 1752

Übersetzung. Installation instructions Page 10. Multi-temperature wine cabinet UWT 1672 / UWK 1752 Übersetzung Installation instructions Page 10 Multi-temperature wine cabinet EN 7080 196-00 UWT 1672 / UWK 1752 Supplied accessories Mounting the dust filter The supplied dust filter prevents that dirt

More information

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm Safety instructions The washing machine is heavy - take care when lifting. Caution: frozen hoses may rip/burst. Do not install the washing machine in areas exposed to frost or outdoors. The washing machine

More information

SuperKlean Washdown Products

SuperKlean Washdown Products DURAREEL DR8 & DR8S INSTALLATION AND MAINTENANCE INSTRUCTIONS **DO NOT THROW AWAY AFTER INSTALLATION** **SAVE AND DISPLAY PROMINENTLY WHERE THIS EQUIPMENT IS USED** GENERAL WARNINGS High pressure and hot

More information

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

Table of Contents.   What to Expect with. Mounting Options. Tools Needed. Wall Control Table of Contents www.casablancafanco.com What to Expect with Your Installation Congratulations on purchasing your new Casablanca ceiling fan! It will provide comfort and performance in your home or office

More information

Installation and maintenance instructions

Installation and maintenance instructions 6304 4995 0/004 GB For installer Installation and maintenance instructions Flue gas heat exchanger WT50/60 Please read thoroughly prior to installation and maintenance. Summary About this manual This equipment

More information

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) P. 1 of 12 JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) Item: Qty: Description: 1 2 1 x 1 x 5/8 Tee Fitting 2 2 Plastic Snap-in Hose Grommet 3 4 1-1/2" Hose Clamps

More information

Packaged Coldroom. Installation Instructions. Operating instructions

Packaged Coldroom. Installation Instructions. Operating instructions Packaged Coldroom Installation Instructions GB Operating instructions Important It is important that the installation instructions are read through and thoroughly understood before commencing the installation

More information

INSTALLATION. Glass Panel Doors (select models) CAUTION

INSTALLATION. Glass Panel Doors (select models) CAUTION Location Do not install refrigerator near oven, radiator or other heat source. If not possible, shield refrigerator with cabinet material. Do not install where temperature falls below 55 F (13 C) or rises

More information

Closomat Lima Vita installation & user guide

Closomat Lima Vita installation & user guide Closomat Lima Vita installation & user guide design manufacture supply install service recycle Technical data The Closomat toilet MUST be installed by a competent or qualified person. Explanation of symbols

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS BUILT-IN BOTTOM MOUNT REFRIGERATOR/FREEZER DBRTGK72SS-GRILLE KIT (FOR designer SERIES ONLY) VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi (MS) 38930 USA (662)

More information

DISTRIBUTION and CONTROL

DISTRIBUTION and CONTROL www.variotherm.at DISTRIBUTION and CONTROL Installation Planning Installation instructions & design manual e9717 Page 2 Table of Contents DISTRIBUTION and CONTROL 1 General information... 3 1.1 Safety

More information

Danfoss Air Heating Surfaces

Danfoss Air Heating Surfaces MAKING MODERN LIVING POSSIBLE Installation Guide www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

MAINTENANCE MANUAL TAIYO SEIKI CO., LTD.

MAINTENANCE MANUAL TAIYO SEIKI CO., LTD. MAINTENANCE MANUAL TAIYO SEIKI CO., LTD. Introduction This Maintenance Manual explains how to replace and adjust the major components of the Automatic Taping Machine when required in daily operation.

More information

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation mfh systems modern floor heating AirUnit Decentralised domestic ventilation Installation instructions List of contents, Installation instructions Page 1. General information... 03 2. Function / planning

More information

HE360 Humidifier Installation Kit

HE360 Humidifier Installation Kit HE360 Humidifier Installation Kit INSTALLATION INSTRUCTIONS WELCOME To the comfortable world of humidified air. When you use your Honeywell humidifier, you notice that your skin is not as dry, and that

More information

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE/ EL CAMINO NOTE: INSTRUCTIONS DEPICT CHEVELLE

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE/ EL CAMINO NOTE: INSTRUCTIONS DEPICT CHEVELLE specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1964-65 CHEVROLET CHEVELLE/ EL CAMINO NOTE: INSTRUCTIONS DEPICT CHEVELLE CONTROL

More information

Cased Aluminum "Convertible" Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC**

Cased Aluminum Convertible Coils 4TXCB003CC3HC** 4TXCB004CC3HC** 4TXCC005CC3HC** 4TXCC006CC3HC** 18- AH44D1-4 Cased Aluminum "Convertible" Coils 4TXCB003CC3HC 4TXCB004CC3HC 4TXCC005CC3HC 4TXCC006CC3HC 4TXCC007CC3HC 4TXCC008CC3HC 4TXCD009CC3HC 4TXCD010CC3HC May be "A" or "B" ALL phases of this installation

More information

Installation instructions

Installation instructions Installation instructions Side-by-Side combinations 211216 7085626-00 SBS... General safety information Contents 1 General safety information... 2 2 External dimensions of the appliance... 2 3 Side-by-side

More information

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing.

Table of Contents What to Expect with Your Installation. Tools Needed. Motor Housing. Table of Contents Congratulations on purchasing your new Casablanca ceiling fan! It will provide comfort and performance in your home or office for many years. This installation and operation manual contains

More information

PAVIA INSTALLATION GUIDE

PAVIA INSTALLATION GUIDE FSP800 PAVIA INSTALLATION GUIDE Parts List Please unpack and inspect all packages and components carefully, make sure they are complete. Examine for shipping damage. If some parts are damaged or missing,

More information

VERTICAL COOKING PRECISIO/PRECIJET COMBI OVEN PRECISIO/ PRECIJET OVENS S.A.V. MAINTENANCE AND REPAIR

VERTICAL COOKING PRECISIO/PRECIJET COMBI OVEN PRECISIO/ PRECIJET OVENS S.A.V. MAINTENANCE AND REPAIR VERTICAL COOKING S.A.V. PRECISIO/ PRECIJET OVENS MAINTENANCE AND REPAIR 27/03/2012 PPS-3BEFM10PC GENERAL Tools Every time this symbol appears, it is imperative to have the appropriate tool in order to

More information

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½ bit Installation Parts and Tools Parts not Provided Electrical cable Water supply tube Fittings for tube Coupler Teflon tape Air gap Wire nuts for 6-gauge wiring Hose clamp ⅞" UL approved strain relief Electrical

More information

thermostatic valve body with stepless precision presetting

thermostatic valve body with stepless precision presetting Thermostatic Radiator Valves V-exact II thermostatic valve body with stepless precision presetting Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING AVANTAGE V-exact II

More information

Moisture inside the drum is due to final testing. Mains cable. Water outlet

Moisture inside the drum is due to final testing. Mains cable. Water outlet Safety instructions Moisture inside the drum is due to final testing. Scope of delivery depending on model The washing machine is heavy - take care when lifting. Caution: frozen hoses can crack/burst.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS BUILT-IN BOTTOM MOUNT REFRIGERATOR/FREEZER BRTGK72SS-GRILLE KIT (FOR PROFESSIONAL SERIES ONLY) VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi (MS) 38930 USA

More information

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro 2006/01 Content Important Information 1. Notes... 3 1.1 CE - Labeling... 3 1.2

More information

Removing shipping locks

Removing shipping locks y Safety instructions Scope of delivery Moisture in the drum is due to end inspection. Removing shipping locks Water connection l The washing machine is heavy - lift with caution. Frozen hoses can tear/burst.

More information

IMI Heimeier Kit Hydroca ble

IMI Heimeier Kit Hydroca ble IMI Heimeier Kit Hydroca ble Thermostatic valves with radiator connection systems Thermostatic valve and lockshield with tube-bend for the installation as angle form or axial form with press- or sliding

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Thermotech underfloor heating

Thermotech underfloor heating Thermotech underfloor heating Assortment and pricelist 2010 Copyright: Thermotech Scandinavia AB 2009 Cover photo: Michael Engman Graphic design: Ulrika Mattisson Other image material: Michael Engman,

More information

VERONA INSTALLATION GUIDE

VERONA INSTALLATION GUIDE FSP800 VERONA INSTALLATION GUIDE Parts List Please unpack and inspect all packages and components carefully, make sure they are complete. Examine for shipping damage. If some parts are damaged or missing,

More information

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...

More information

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA

2/4TXCC037BC3HCA 2/4TXCB042BC3HCA 4TXCC044BC3HCA 2/4TXCC043BC3HCA 2/4TXCB048BC3HCA 18- AH39D1-4 Cased Aluminum "Convertible" Coils 2/4TXCA018BC3HCA 2/4TXCA024BC3HCA 2/4TXCB025BC3HCA 2/4TXCB031BC3HCA 4TXCB032BC3HCA 2/4TXCB036BC3HCA ALL phases of this installation must comply with NATIONAL,

More information

Model: 1100 Float-Controlled Condensate Trap, PN 25

Model: 1100 Float-Controlled Condensate Trap, PN 25 1 Safety instructions Model: 1100 Float-Controlled Condensate Trap, PN 25 1.1 Proper use Any improper use, intervention in the design and deviation from the design data automatically lead to termination

More information

PIPE DREAMS 96. Aeroponic Garden IMPORTANT:

PIPE DREAMS 96. Aeroponic Garden IMPORTANT: 1 WARNING: BEFORE PUTTING WATER PUMP INTO OPERATION FILL UP NUTRIENT TANK TO TOP OF PUMP. THE PUMP MUST NEVER RUN DRY OTHERWISE, WARRANTY WILL BE DECLINED. READ FILLING INSTRUCTIONS BEFORE USE. Welcome

More information

INSTALLATION INSTRUCTIONS. Aluminum Blinds - Standard - - Lift & Lock -

INSTALLATION INSTRUCTIONS. Aluminum Blinds - Standard - - Lift & Lock - 1 INSTALLATION INSTRUCTIONS Aluminum Blinds - Standard - - Lift & Lock - 1 Deluxe 1 Traditional 1 Value & 1 Basic 2 Macro Thank you for your purchase. This blind has been custom built for you from the

More information

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG

LINE SET DUCT AND ACCESSORY PRODUCT CATALOG VAC LINE SET DUCT AND ACCESSORY PRODUCT CATALOG Correctly installing an air conditioner requires the use of dedicated accessories. When the customer invests in an air conditioner, he relies on the professional

More information

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1960-66 FORD PICKUP CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect

More information

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting For reversed flow direction Thermostatic Radiator Valves Thermostatic valve body with and without presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / For reversed flow direction For reversed

More information

2" and 2 1/2" Wood Horizontal Blinds 2", 2 1/4" and 2 1/2" Faux Wood Horizontal Blinds. Installation & Operating Instructions

2 and 2 1/2 Wood Horizontal Blinds 2, 2 1/4 and 2 1/2 Faux Wood Horizontal Blinds. Installation & Operating Instructions 2" and 2 1/2" Wood Horizontal Blinds 2", 2 1/4" and 2 1/2" Faux Wood Horizontal Blinds Installation & Operating Instructions TC07-08.2011 TABLE OF CONTENTS Product View...3 GETTING STARTED...4 Tools Required:...4

More information

BMW E36 Thermostat Removal And Coolant Flush

BMW E36 Thermostat Removal And Coolant Flush BMW E36 Thermostat Removal And Coolant Flush Disclaimer: The cooling system is critical to the proper operation of your car. Failure to properly install all of the components of the cooling system could

More information

Owner s Guide and Installation Manual

Owner s Guide and Installation Manual Tribeca Owner s Guide and Installation Manual English Form# M6000-01 20120416 2012 Casablanca Fan Co. Welcome Your new Casablanca ceiling fan is an addition to your home or office that will provide comfort

More information

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l Installation instructions for contractors VIESMANN Vitocell 300-B Type EVBA-A Dual mode DHW cylinder, 300 and 500 l VITOCELL 300-B 1/2017 Dispose after installation. Safety instructions Please follow these

More information