Qualification Test Report 1/Jul/2005 Rev. A

Size: px
Start display at page:

Download "Qualification Test Report 1/Jul/2005 Rev. A"

Transcription

1 Qualification Test Report 1/Jul/2005 Rev. A AMP CO 10 Gigabit/s Insert PN X 1. INTRODUCTION 1.1 Purpose Testing was performed on AMP* CO 10 Gigabit/s Insert, to determine its conformance to the requirements of AMP Product Specification , Rev. B. 1.2 Scope This report covers the electrical, mechanical, environmental and transmission performance of the AMP CO 10 Gigabit/s Insert, manufactured by Tyco Electronics Raychem S. A. The testing was performed between March 17, 2005 and June 7, Conclusion The AMP CO 10 Gigabit/s Insert meets the electrical, mechanical, environmental and transmission performance requirements of AMP Product Specification , Rev. B. 1.4 Product Description The AMP CO 10 Gigabit/s Insert is a connector used to provide a universal connection interface between premise wiring of an office and the user s network of communications equipment. 1.5 Test Samples The test samples were randomly selected from normal current production lots, and the following part numbers were used for test: 15 samples of AMP CO 10 Gigabit/s Insert classified in groups. Test Group Qty Part Number Description 1, 2, AMP CO 10 Gigabit/s Insert. 1.6 Qualification Test Sequence Test Group Test or Examination Test Sequence (a) Examination of product 1, 10 1, 10 1, 5 Contact resistance and shield 2, 9 2, 4 termination resistance Insulation Resistance 4, 8 Dielectric Withstanding Voltage 5, 7 Current-Carrying Capacity 3 PS Near-end Crosstalk 2, 9 Insertion Loss 3, 8 Return loss 4, 7 PS ELFEXT 5 Stress Relaxation 6 6 Corrosion testing 3 DR DATE E. Bargalló ** / A. Ruesca ** 1/Jul/2005 Rev. A, Issue APVD DATE J. Pelai ** 1/Jul/2005 Tyco Electronics AMP España, S.A., Barcelona, Spain This specification is a controlled document. * AMP and AMP Netconnect are trademark of Tyco Electronics ** Signatures on File 1 of 5

2 2. SUMMARY OF TESTING 2.1 Examination of product All Groups All samples submitted for testing were selected from normal current production lots. They were inspected and accepted by the product Assurance Department. 2.2 Input to output Resistance Groups 1 and 3. All initial termination resistance measurements values with low level method were lower than 200mOhm: 65 mohm maximum measured. All final termination resistance measurements values with low level method were lower than 200mOhm: 106 mohm maximum measured. 2.3 Shield Termination Resistance Groups 1 and 3. All initial shield termination resistance measurements values with low level method were lower than 100 mohm: 18 mohm maximum measured. All final shield termination resistance measurements values with low level method were lower than 100mOhm: 40 mohm maximum measured. 2.4 Insulation Resistance Group 1. All initial insulation resistance measurements values were higher than Ω: Ω minimum measured. All final insulation resistance measurements values were higher than Ω: Ω minimum measured. 2.5 Dielectric Withstanding Voltage Group 1. No dielectric breakdown or flashover occurred during the test, having applied 1500 VAC Peak between contacts and shield and 1000 VAC Peak between adjacent contacts. 2.6 Current Carrying Capacity Samples 1.1, 1.2 and 1.3. Rev. A 2 of 5

3 2.7 Transmission Tests Group 2. Samples tested meet the requirements of Transmission tests for Cat 6A according to ISO NWIP 981, and related standards. 2.8 Stress Relaxation Groups 1 and 3. No physical damage occurred to the samples after Stress Relaxation test. 2.9 Corrosion Testing Group 3. No physical damage occurred to the samples after Corrosion test. Rev. A 3 of 5

4 3. TESTS METHODS 3.1 Examination of product ( Reference Standard: IEC 60512, test 1a, 1b ) Product drawings and inspections plans were used to examine the samples. They were examined visually and functionally. 3.2 Contact Resistance and Shield Termination Resistance (Reference Standard: IEC 60512, test 2a) Contact Resistance and Shield Termination Resistance measurements at low level current were made using four terminal technique (Figure 1). Figure Insulation Resistance (Reference Standard: IEC 60512, test 3a) Insulation Resistance was measured between adjacent contacts and between contacts and shield using a megaohmmeter applying 100 V DC. 3.4 Dielectric Withstanding Voltage ( Reference Standard: IEC 60512, test 4a ) A 1000 V DC or AC peak voltage was applied between adjacent contacts during 60 s. A 1500 V DC or AC peak voltage was applied between contacts and shield during 60 s. Maximum leakage current: 5 ma. 3.5 Current Carrying Capacity (Reference Standard: IEC 60512, test 5b) The contact temperature at several current steps was measured. The maximum allowed temperature minus the measured temperature increase was plotted vs. current. 3.6 Transmission Tests ( Reference Standard: ISO NWIP 981 and related standards ) Insertion Loss, NEXT, FEXT and Return Loss were measured according to the standard ISO NWIP Stress Relaxation (Reference Standard: IEC 60512, test 11i) Samples were placed into an oven at 70º C for 500 h. Rev. A 4 of 5

5 3.8 Corrosion Testing ( Reference Standard: IEC and IEC ) Samples were placed during 4 days in a chamber with: SO 2 = 0.5 ppm (Volume), H 2 S = 0.1ppm (Volume), T = 25º C +/-2º C, HR = 75 % +/-3 %. Rev. A 5 of 5

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems Qualification Test Report 501-93032 14/April/2011 Rev A AMP-TWIST Series Jacks for Class EA systems 1. INTRODUCTION 1.1 Purpose Qualification testing on AMP-TWIST* Series Jacks for Class E A Systems, to

More information

Product Specification CAT 6 UNSHIELDED PATCH CORDS

Product Specification CAT 6 UNSHIELDED PATCH CORDS Product 108-93017 Specification 23/Nov/06 Rev. A CAT 6 UNSHIELDED PATCH CORDS 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for NETCONNECT

More information

/Oct/2014 Rev E

/Oct/2014 Rev E Product Specification 108-93017 14/Oct/2014 Rev E Cat 6 Unshielded Patch Cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE Connectivity

More information

Cat 6 Unshielded Patch cords

Cat 6 Unshielded Patch cords Product Specification 108-93017 13/Oct/2009 Rev D Cat 6 Unshielded s 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT* Cat

More information

Cat 6 Shielded Patch cords

Cat 6 Shielded Patch cords Product Specification 108-93010 14/Oct/2009 Rev E Cat 6 Shielded Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for AMP NETCONNECT*

More information

/Oct/2014 Rev B

/Oct/2014 Rev B Product Specification 108-93042 07/Oct/2014 Rev B Class EA shielded solid Patch cords 1. SCOPE 1.1 Content This specification describes performance and material requirements and tests procedures for TE

More information

/Mar/2014 Rev A

/Mar/2014 Rev A Qualification Test Report 501-93038 21/Mar/2014 Rev A MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC 1. INTRODUCTION 1.1 Purpose Tests performed on MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC,

More information

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector PRODUCT SPECIFICATION 108-115057 29OCT13 Rev. A1 0.5mm Fine Stacking Hermaphroditic Type BTB Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for 0.5mm

More information

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date: Energy Report EDR-5391 Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49 Qualification Testing of Nuclear High Voltage Splice (NHVS) Enclosures: Report Number: Date: EDR-5391

More information

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT) Product 108-5390 Specification 31 OCT 17 Rev.F1 Free Height 0.8 mm Pitch Board-to-Board Connector (SMT) 1. SCOPE 1.1. Contents This specification covers the requirements for product performance, test methods

More information

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications : 1. Scope : 1.1 Contents 11JUL07 Rev. F DDR S.O.DIMM Socket 200 Positions This specification covers the requirements for product performance, test methods and quality assurance provisions of DDR S.O.DIMM

More information

Jun08 Rev A

Jun08 Rev A Product Specification Terminal Block Crimp Snap Plug Assembly 108-2319 09Jun08 Rev A 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Tyco Electronics

More information

Mar11 Rev B

Mar11 Rev B Product Specification 108-1576-2 11Mar11 Rev B NETCONNECT*, CHAMP* System 5 Modular Jack Patch Panel 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for NETCONNECT*

More information

Jan05 Rev A EC

Jan05 Rev A EC Product Specification Two Circuit Heavy Duty Burner Connector 108-1056 12Jan05 Rev A EC 0990-0059-05 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the

More information

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. Product Specification 108-93018 25/Aug/2011 Rev H Copper LAN cable 1. SCOPE 1.1. Content This specification describes the general requirements for AMP NETCONNECT* copper LAN cable. 2. APPLICABLE DOCUMENTS

More information

Two Circuit Heavy Duty Burner Connector

Two Circuit Heavy Duty Burner Connector Product 108-1056 11 Oct.16 Rev B Specification EC 0990-0059-05 Two Circuit Heavy Duty Burner Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the

More information

Mar11 Rev C

Mar11 Rev C Product Specification 108-1441 11Mar11 Rev C Connector, Z-PACK*, 2 mm FB, Signal and Power 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Z-PACK* 2mm

More information

JUL 18 Rev A1

JUL 18 Rev A1 Qualification Test Report 501-166004 30 JUL 18 Rev A1 Mini USB-B Header, H-Type SMT 1. INTRODUCTION 1.1. Purpose Testing was performed on the Mini USB-B Header, H-Type SMT to determine if it meets the

More information

Qualification Test Report LC Duplex Adapter For LC Cutouts

Qualification Test Report LC Duplex Adapter For LC Cutouts Qualification Test Report LC Duplex Adapter For LC Cutouts 501-683 09Mar09 Rev B 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LC Duplex Adapters for LC Cutouts, to determine their

More information

Jun08 Rev C

Jun08 Rev C Product Specification Connector, Card Edge,.050 Centerline 108-14034 02Jun08 Rev C 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for Tyco Electronics.050 centerline

More information

HOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC.

HOUSING ASSY 5 POS. HYBRID STD/JR POWER TIMER TAB & REC. 108-37065 Product Specification Rev. A 18-Jan-2007 Housing Assy 5p Hybrid Std./Jr. Power Timer Tab & Rec. DESIGN OBJECTIVES The product described in this document has not been fully tested to insure conformance

More information

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products

Side Entry Insulation Damage Repair Sleeve (SEIDRS) Raychem Devices Products 1.0 Scope This specification covers the design, performance and qualification requirements for Raychem Side Entry Insulation Damage Repair Sleeve. 1.1 Description. Raychem SEIDRS covered by this specification

More information

Jul07 Rev C

Jul07 Rev C Product Specification 108-2167 11Jul07 Rev C MPO and MPO SECURE Multimode Fiber Optic Connector and Adapter 1. SCOPE 1.1. Content This specification, which is based on GR-1435-CORE, covers the performance,

More information

Nuclear Products Requalification Testing Phase 2. Title Pages: 113. Report Number: EDR-5389 Rev. 0 12/10/2004. Approved by: Signature: Date:

Nuclear Products Requalification Testing Phase 2. Title Pages: 113. Report Number: EDR-5389 Rev. 0 12/10/2004. Approved by: Signature: Date: Energy Report EDR-5389 Nuclear Products Requalification Testing Phase 2 Title Pages: 113 Nuclear Products Requalification Testing Phase 2 Enclosures: Report Number: Date: EDR-5389 Rev. 0 12/10/2004 Prepared

More information

HMN-D2 Insert Series

HMN-D2 Insert Series HMN-D2 Insert Series Table of contents 1. SCOPE... 2 1.1. Content... 2 1.2. Qualification... 2 2. APPLICABLE DOCUMENTS... 2 2.1. TE Connectivity Documents... 2 2.2. Other Documents... 2 3. REQUIREMENTS...

More information

Apr06 Rev A

Apr06 Rev A Qualification Test Report LC, Multimode, One-Piece Housing, Fiber Optic Connector 501-628 03Apr06 Rev A 1. INTRODUCTION 1.1. Purpose 1.2. Scope Testing was performed on Tyco Electronics LC multimode, one-piece

More information

Jan07 Rev B

Jan07 Rev B Qualification Test Report 501-545 05Jan07 Rev B MT-RJ Patch Panel and Outlet Jacks (Standard, XG, SECURE and SECURE XG) 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics MT-RJ Jack,

More information

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) 02Oct08 Rev A 1. SCOPE 1.1. Content This specification, based on IEC 61753-1 Edition 1.0 tests for Category E (Extreme Environment),

More information

USB 3.0 Plug & Receptacle

USB 3.0 Plug & Receptacle US 3.0 Plug & Receptacle 1. Scope: 1.1 Contents: This specification covers the requirements for product performance, test methods and quality requirements of Tyco Electronics Universal Serial us (US) consortium

More information

MODULAR CONNECTOR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION

MODULAR CONNECTOR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION MODULAR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION 108-18965 Product Specification 108-18965 10.02. 2011 Rev C1 MODULAR 154 (58 AND 96) POSITION, WATERPROOF CONTENT : 1 PRODUCT OVERVIEW 1.1

More information

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable) 501-586 26Feb09 Rev F 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LightCrimp*

More information

FEB. 17 Rev. A1

FEB. 17 Rev. A1 Product Specification 108-94552 10 FEB. 17 Rev. A1 The product described in this document has not been fully tested to ensure conformance to the requirements outlined below. Therefore, TE Connectivity

More information

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Energy Division   Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv Energy Division http://energy.tycoelectronics.com Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv R Heat-shrinkable joints for halogen-free, flame-retardant

More information

Fiber Optic Distribution Cables (6-144 Fibers)

Fiber Optic Distribution Cables (6-144 Fibers) 900um Buffered Aramid Yarn Strength Members Outer 6 or 12 Subunit Central Strength Member Outer Ripcord Single Unit Cable 6-24 Multi-Unit Cable 24-144 Description: AMP NETCONNECT distribution cables are

More information

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165 PRODUCT SPECIFICATION Sep 22, 29 Rev. B CONNECTOR, SINGLE CAVITY, AEROSPACE, PANEL MOUNT, FLOATING, EN416 1 - SCOPE 1.1. Content This document covers the performances, tests, and quality requirements of

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic

More information

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES SPECIFICATION AND PERFORMANCE OF MDP CONNECTOR SERIES CIRCUIT ASSEMBLY CORP. 18 THOMAS STREET, IRVINE, CA 92618-2777 Page No. 1 of 16 CLAUSE CONTENTS PAGE 1.0 SCOPE... 3 2.0 APPLICABLE DOCUMENTS... 3 3.0

More information

SolderSleeve Insulated Electrical Termination Devices

SolderSleeve Insulated Electrical Termination Devices Tyco Electronics Corporation 300 Constitutional Drive Menlo Park, CA 94025 USA Specification This Issue: Date: Replaces: RT-1404 ISSUE 9 April 20, 2000 ISSUE 8 1.0 INTRODUCTION SolderSleeve Insulated Electrical

More information

Page 2 of 14 Report Ref. No

Page 2 of 14 Report Ref. No age 2 of 14 Summary of testing: Tests performed (name of test and test clause): Clause 6.1, Initial measurements: - MST 01: Visual inspection - 10.2: Maximum power determination - MST 16: Dielectric withstand

More information

Table of Contents. Section Title Page 1.0 SUMMARY TEST SPECIMEN Materials and Construction 3.0 TEST PROGRAM 2

Table of Contents. Section Title Page 1.0 SUMMARY TEST SPECIMEN Materials and Construction 3.0 TEST PROGRAM 2 EDR-5210 01/07/92 Table of Contents Section Title Page 1.0 SUMMARY 1 2.0 TEST SPECIMEN 2 3.0 2.1 Materials and Construction 3.0 TEST PROGRAM 2 3.1 Test Sequence 3.2 Functional Test Procedures 3.3 Specimen

More information

TABLE OF CONTENTS. Section Title Page 1.0 SUMMARY TEST SPECIMEN Materials and Construction TEST PROGRAM 4

TABLE OF CONTENTS. Section Title Page 1.0 SUMMARY TEST SPECIMEN Materials and Construction TEST PROGRAM 4 TABLE OF CONTENTS Section Title Page 1.0 SUMMARY 1 2.0 TEST SPECIMEN 2 2.1 Materials and Construction 2 3.0 TEST PROGRAM 4 3.1 Test Sequence 4 3.2 Functional Test Procedures 5 3.3 Specimen Preconditioning

More information

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES SECTION 26 36 23 AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION

OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION APPROVED BY: THOMAS PEEL PRESIDENT AND DIRECTOR OF TEST PROGRAM DEVELOPMENT CONTECH RESEARCH, INC. ATTLEBORO,

More information

Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series. Energy Division

Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series. Energy Division Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series Energy Division http://energy.tycoelectronics.com Bowthorpe Surge Arresters OCP, Open Cage Polymeric series Bowthorpe pioneered the development

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint

More information

TE CONNECTIVITY S CYLINDER HEAD WIRING SOLUTIONS FOR INDUSTRIAL & COMMERCIAL VEHICLES

TE CONNECTIVITY S CYLINDER HEAD WIRING SOLUTIONS FOR INDUSTRIAL & COMMERCIAL VEHICLES TE CONNECTIVITY S CYLINDER HEAD FOR INDUSTRIAL & COMMERCIAL VEHICLES WE GO TO EXTREMES TO MAKE EVERY CONNECTION COUNT INDUSTRIAL & COMMERCIAL TRANSPORTATION /// CYLINDER HEAD FOR INDUSTRIAL & COMMERCIAL

More information

MXSU - Selection table 3-core Kits / X-section

MXSU - Selection table 3-core Kits / X-section MXSU - Selection table 3-core Kits / X-section Voltage Cables with wire screen Uo/U (Umax) Kit-number Appl. range (based on Al/rm) 6/10 (12) MXSU 3311 1x 35-95 MXSU 3331 1x 95-240 8.7/15 (17.5) MXSU 4311

More information

CII FCAC-150 Series Relay

CII FCAC-150 Series Relay Introducing CII Series Relay 50 Amps, 1PST/NO (DM) CII Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts KEY FEATURES Non-latching relay Balanced force design Corrosion protected metal enclosure

More information

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket 870 LIMOGES Cedex Telephone: + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Mosaic TM LCS2 socket Page 765 73 794 76 1. General characteristics....1 2. Presentation...1 3. Installation...1 4. Technical

More information

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series Energy Division Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series At the core of the Bowthorpe OCP design is our improved ZnO varistor disk, which has superior thermal and electrical characteristics

More information

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS...

Table of Contents FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS REQUIREMENTS... TITLE SPECIFICATION FOR PHOTOELECTRIC CONTROL UNITS (PECUs) REFERENCE REV DATE: JUNE 2017 PAGE: 1 OF 16 REVISION DATE: Table of Contents FOREWORD... 3 INTRODUCTION... 4 1 SCOPE... 4 2 NORMATIVE REFERENCES...

More information

ATUM: General Purpose Thin Wall Tubing - with Adhesive (Black) Medium Wall: MWTM: General Purpose Medium Wall Tubing

ATUM: General Purpose Thin Wall Tubing - with Adhesive (Black) Medium Wall: MWTM: General Purpose Medium Wall Tubing Exit Catalogue Return to Contents Energy Division http://energy.tycoelectronics.com Section 1: Heat Shrink Tubing. Thin Wall: RNF: General Purpose Thin Wall Tubing - without adhesive (Black and Colours)

More information

MT-RJ Optical Fiber System Field Testing

MT-RJ Optical Fiber System Field Testing MT-RJ Optical Fiber System Field Testing Table of Contents INTRODUCTION... 3 TEST JUMPERS... 4 LAUNCH CONDITIONS... 4 MT-RJ TEST KITS... 5 MT-RJ SYSTEM TESTING: Fixed transmit and receive (SC or ST-style)

More information

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS)

SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS) SUGGESTED SPECIFICATION For Series 300 Manual Transfer Switches (3MTS) PART 1 GENERAL 1.01 Scope Furnish and install manual transfer switches (3MTS) with number of poles, amperage, voltage, and withstand

More information

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC) Energy Division Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC) Bowthorpe EMP distribution metal oxide surge arrester DA0 series Tyco Electronics Bowthorpe EMP business

More information

.025 Connector Series

.025 Connector Series Highlights Automotive connector series: 30 % smaller size than the existing.040 III connectors and designed to resist fretting corrosion. Features.025 Connectors with a full range of product lines..025

More information

WIO200 Water in oil sensor

WIO200 Water in oil sensor WIO200 Water in oil sensor User manual Rev. 1.15 Dato: 2011-11-03 Page 1 of 24 TABLE OF CONTENTS Table of contents... 2 Introduction... 3 Safety Advice... 4 Function... 6 Normal operation... 7 Failure

More information

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product

More information

Arteor TM LCS2 Cat. 6A UTP RJ 45 socket

Arteor TM LCS2 Cat. 6A UTP RJ 45 socket 87045 LIMOGES Cedex Telephone: + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Arteor TM Page 5 723 49 5 723 57 1. General characteristics....1 2. Presentation...1 3. Real life scenarios...1 4. Technical

More information

SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxNSA-L Series. Benefits: Features: Applications: Raychem Circuit Protection's SiBar thyristor surge protection devices are designed to help protect sensitive telecommunication equipment from the hazards caused by lightning, power contact, and power induction.

More information

AD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS)

AD0412HB-C71GP (P) P.S. REV. DC FAN (RoHS) AD0412HB-C71GP DC FAN (RoHS) P.S. REV. (P) A Y D A T A - S H E E T Engineering Printed On: 11/07/18 BRUSHLESS AXIAL COOLING FANS Customer Ref: (RoHS) Adda Model No AD0412HB-C71GP P.S: (P) Samples attached

More information

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM APPLICATION OVERVIEW Control and monitoring systems play an essential role in heat tracing applications which range from freeze protecting water lines to

More information

TEMPORARY IMMERSION AND DUST TEST REPORT

TEMPORARY IMMERSION AND DUST TEST REPORT Report No. :HS1007140060A Version:A TEMPORARY IMMERSION AND DUST TEST REPORT Company :Gold Apollo Co., Ltd Address :3F.-1, No.77, Sec. 1, Xintai 5th Rd., Xizhi City, Taipei County 221, Taiwan (R.O.C.)

More information

Section 8: Switchgear Connections (Straight & Elbows)

Section 8: Switchgear Connections (Straight & Elbows) 8: Switchgear Connections (Straight & Elbows) HEAT SHRINKABLE RSRB Inline and Right Angle Bushing Boots 126 PUSH ON ELBOWS RCAB-41 Elastomeric Flexible Bushing Boot - up to 17.5kV 127 RCAB-51 Inline Cold

More information

SiBar Thyristor Surge Protectors. TVBxxxSA-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxSA-L Series. Benefits: Features: Applications: Raychem Circuit Protection's SiBar thyristor surge protection devices are designed to help protect sensitive telecommunication equipment from the hazards caused by lightning, power contact, and power induction.

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61156-4 Edition 3.0 2009-05 Multicore and symmetrical pair/quad cables for digital communications Part 4: Riser cables Sectional specification INTERNATIONAL ELECTROTECHNICAL

More information

The next generation thermometer from the global leader

The next generation thermometer from the global leader akm oti/wti Remote mount thermometers The next generation thermometer from the global leader Accomplish the most demanding control and alarm configurations Reduce failure costs with reliable AKM bellows

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/XXX Original: English Distribution: General TITLE: Integrated electronic maximum-minimum thermometer, with factory programmed alarms, for vaccine refrigerators

More information

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM APPLICATION OVERVIEW Control and monitoring systems play an essential role in heat tracing applications which range from freeze protecting water lines to

More information

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies APPLICATIONS High Speed I/O Multiple Channels Interconnects Switches for Fibre Channel and InfiniBand Standards TECHNICAL DOCUMENTS

More information

Wood pellet and biomass system ceramic igniter

Wood pellet and biomass system ceramic igniter Wood pellet and biomass system ceramic igniter Specification Data Product name: Ceramic Igniter PSx-6-240-B Drawing number: IBA-HH008A Revised on: 2015.12.20 1. Application This engineering specification

More information

SPECIFICATION FOR APPROVAL

SPECIFICATION FOR APPROVAL SPECIFICATION FOR APPROVAL Customer : STD Description : DC FAN Customer Part No. REV. : Delta Model No. : REV. : 00C Sample Issue No. : Sample Issue Date : 2017/7/7 PLEASE SEND ONE COPY OF THIS SPECIFICAITON

More information

TEMPORARY SPECIFICATION FOR REFERENCE

TEMPORARY SPECIFICATION FOR REFERENCE TEMPORARY SPECIFICATION FOR REFERENCE Customer : Description : EST FAN (Energy Saving Technology Fan) Customer Part No. REV. : Delta Model No. AFL12AUHE-00 REV. : 02 Sample Issue No. : Sample Issue Date

More information

Comparison of IEEE 323 and IEC Shows Notable Consistency (cont)

Comparison of IEEE 323 and IEC Shows Notable Consistency (cont) International Electrotechnical Commission (IEC) 60780 Nuclear power plants Electrical equipment of the safety system Qualification Richard T. Wood Oak Ridge National Laboratory presented at IEEE Subcommittee

More information

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies APPLICATIONS High Speed I/O Multiple Channels Interconnects Switches for Fibre Channel and Infiniband Standards Internal and External

More information

Multi-Core Fire Resistant Cable

Multi-Core Fire Resistant Cable Fire Resistant Cables / Multi-Core Fire Resistant Cable Approved to UL 444, Zeta ZFP series cables have received UL approval for standard applications. Standards Alarm Cable Z UL 444 Approval CMH Rated

More information

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING Page 1 of 10 CONTENTS 1 SCOPE 2 DEFINITIONS 2.1 SURGE ARRESTER 2.2 GAPLESS METAL-OXIDE SURGE ARRESTERS 2.3

More information

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES KEY FEATURES Hermetically sealed intrinsically safe. Operates in explosive/harsh environments without oxidation or contamination of contacts, including long periods of non-operation 8kV isolation between

More information

Arteor TM LCS2 Cat. 6A STP RJ 45 socket

Arteor TM LCS2 Cat. 6A STP RJ 45 socket 87045 LIMOGES Cedex Telephone: + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Arteor TM Page 5 723 06 5 723 50 1. General characteristics....1 2. Presentation...1 3. Real life scenarios...1 4. Technical

More information

CLASSIFICATION Constructional Data Report (CDR)

CLASSIFICATION Constructional Data Report (CDR) CLASSIFICATION Constructional Data Report (CDR) 1.0 Reference and Address Report Number 100358381SAT-001 Original Standard(s) Fire Test for Heat and Visible Smoke Release for Discrete Products and Their

More information

Introducing Hermaphroditic Blade and Receptacle Connector

Introducing Hermaphroditic Blade and Receptacle Connector Introducing Hermaphroditic Blade and Receptacle Connector Wire-to-Board, Board-to-Board and Dust Cover Hermaphroditic Blade and Receptacle Connector : Wire-to-Board KEY FEATURES Available in 2, 4, and

More information

/ XPS Interconnection Diagrams

/ XPS Interconnection Diagrams 4100-5153/4100-5154 XPS Interconnection Diagrams Introduction This publication provides interconnection diagrams for 4100-5153 (120 VAC) and 4100-5154 (220/240 VAC) 13 A Expansion Power Supplies (XPS).

More information

the next generation thermometer from the global leader

the next generation thermometer from the global leader OTIWTI Remote mount thermometers (AKM) the next generation thermometer from the global leader Six switch capability, sequentially independent, with adjustable hysteresis Reduce failure costs with reliable

More information

APR 17 Rev A

APR 17 Rev A Product Specification 108-130015 11 APR 17 Rev A ChipConnect Cable Assembly 1. SCOPE 1.1. Content This specification covers performance, test and quality requirements for the ChipConnect Cable Assembly

More information

Energy Division

Energy Division Energy Division http://energy.tycoelectronics.com Terminations for polymeric and MIND paper insulated cables from 7.2 kv up to 36 kv System Designer R Termination systems designer This worksheet enables

More information

Energy Division. Raychem Insulation Enhancement Systems

Energy Division. Raychem Insulation Enhancement Systems Energy Division Raychem Insulation Enhancement Systems Raychem Insulation Enhancement System Based on Tyco Electronics Raychem long experience in polymer technology and sealing systems for energy networks

More information

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission ADDISON Flame Retardant CAT5e Data Cables FTX-CAT5e U/UTP4P24 FTX-CAT5e f/utp4p24 FTX-CAT5e sf/utp4p24 LSZH Outer Aluminium/Polyester Tape Solid Copper Conductor PE Insulation Tinned Copper Drain Wire

More information

RICS. Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv

RICS. Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv R RICS Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv RICS Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv The increasing popularity of

More information

Z-PACK TinMan 85 ohm Connector Overview

Z-PACK TinMan 85 ohm Connector Overview Z-PACK TinMan 85 ohm High Speed Backplane Connector Z-PACK TinMan 85 ohm Connector Overview Product Facts 10+ Gbps performance 85 ohm impedance for differential pair configuration 5 pair version offers

More information

HTC-915-CONT. Heat-Trace Control system

HTC-915-CONT. Heat-Trace Control system Heat-Trace Control system Product overview The Raychem HTC-915 system is a compact, full-featured microprocessor-based single-point heat-trace controller. The HTC-915-CONT provides control and monitoring

More information

CAN/ULC-S109 Flame Resistance of "Xanadu" Material

CAN/ULC-S109 Flame Resistance of Xanadu Material CAN/ULC-S109 Flame Resistance of "Xanadu" Material A Report To: Design/Craft Fabric Corporation 2230 Ridge Dr. Glenview, IL 60025 USA Phone: (847) 904-7000 E-mail: mboynton@design-craft.com Attention:

More information

M5200 Industrial Pressure Transducer

M5200 Industrial Pressure Transducer SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof UL Certified Gage, Sealed, Compound

More information

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012372 / 03.2015 isopv

More information

(P) AD0612VB-A7BGP P.S. REV. DC FAN (RoHS)

(P) AD0612VB-A7BGP P.S. REV. DC FAN (RoHS) AD0612VB-A7BGP DC FAN (RoHS) P.S. REV. (P) C Y D A T A - S H E E T Engineering BRUSHLESS AXIAL COOLING FANS Customer Adda Model No AD0612VB-A7BGP P.S: (P) Samples attached Piece(s), Safety Approval UL,CUL,TUV,CE

More information

Introducing SlimSeal SSL Connector

Introducing SlimSeal SSL Connector Introducing SlimSeal SSL Connector The SlimSeal SSL connectors are low profile, single row connectors developed for indoor and outdoor LED lighting applications. These connectors provide low power, sealed

More information

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING. BENEFITS Suitable for high speed data transmission applications Longer battery life due to low leakage current Board space savings Help protect sensitive electronic circuits against electrostatic discharge

More information

Product Data Sheet 4114 N/17HH-218. The engineer's choice

Product Data Sheet 4114 N/17HH-218. The engineer's choice The engineer's choice 4114 N/17HH-218 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Electrical Operating Data... 4 3.2 Electrical Interface - Output

More information

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications:

SiBar Thyristor Surge Protectors. TVBxxxRSC-L Series. Benefits: Features: Applications: Circuit Protection's SiBar thyristor surge protection devices are designed to help protect sensitive telecommunication equipment from the hazards caused by lightning, power contact, and power induction.

More information

Rules for Classification and Construction Additional Rules and Guidelines

Rules for Classification and Construction Additional Rules and Guidelines VI Rules for Classification and Construction Additional Rules and Guidelines 7 Guidelines for the Performance of Type Approvals 7 Test Requirements for Statical Converters with Semi-Conductors Edition

More information

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM 2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40

More information