1 PREFACE This specification is provided to allow the professional involved in specifying an Emergency Call System to generate an accurate document which will include the required functions for a specific facility. This document contains all major products and functions of the system. This document should be modified by adding, deleting or changing as required. It is strongly suggested that the modified document be reviewed by Heritage MedCall to ensure accuracy. Heritage MedCall can provide this document in various electronic formats to facilitate editing. Contact Heritage MedCall at or @heritagemedcall.com for assistance with this document. CONTENTS 1. Related Documents 2. General 3. Quality Assurance 4. Scheduling 5. Warranty 6. Maintenance 7. Demonstration and Training 8. Products 9. Master Computer 10. Master Computer Operation 11. Network Controller 12. High-Power Repeater 13. Transmitters Battery Powered a. Water-Resistant Single Button Transmitter b. Wireless Pull-cord Transmitter c. Wireless Single Patient Station d. Universal Wireless Transmitter e. Universal Door/Window Transmitter f. Wireless Smoke Detector g. Wireless Motion Detector 14. Transmitters Building Powered a. Wireless Pull-cord Transmitter Normally Open b. Wireless Pull-cord Transmitter Normally Closed 15. Call Accessories a. 8 Pushbutton Call Cord b. 2-1 Call cord adapter 16. Annunciation a. 1 Color Dome Light b. 2 Color Dome Light c. 4 Color Dome Light d. LED Dome Light e. Marquis Display f. Paging Transmitter g. Pagers Filename: A&EWirelessSpec doc

2 1. RELATED DOCUMENTS a. National Electrical Code b. Authorized Distributor Letter from manufacturer upon request of specifying authority. c. Applicable state and local codes and ordinances. c. Applicable state licenses d. Drawings and general provisions of the contract, including general and supplementary conditions. 2. GENERAL The contractor will furnish all labor, equipment and materials necessary for the installation of a complete wireless emergency call system. The installed system will meet the following minimum requirements: a. Operate in the MHz. frequency band and comply with all applicable FCC regulations. b. Transmit all alarms utilizing frequency-hopping spread-spectrum technology, which will send redundant messages across a minimum bandwidth of 10 MHz. for maximum effectiveness and reliability. c. All equipment in the system will be fully supervised. Every device in the system will transmit a periodic supervisory message containing the device ID and its status including battery condition. Every device will transmit its status multiple times daily to ensure total system integrity. d. The system will be totally wireless utilizing radio frequencies (RF) for all communication between alarm devices, all repeaters and the receiver connected to the controlling computer. e. The system will support remotely powered pull-cord transmitters to remove the requirement for battery replacement. A suitable 12VDC building power supply will provide power for these devices. f. All repeaters will contain battery backup to provide uninterrupted integrity of the wireless infrastructure. g. The system will be capable of supporting up to 8000 devices with full supervision when using a HM-6040 Network Coordinator Receiver. h. The system will be capable of supporting up to 3000 devices with full supervision when using a HM-6080 Area Control Gateway Controller. 3. QUALITY ASSURANCE a. Installer Qualifications: The entire system shall be installed by a single factory authorized contractor with a minimum of five years experience designing, installing and servicing similar low voltage or RF equipment used in security, fire alarm or access control. b. Manufacturer Qualifications: Engage a firm with a minimum 10 year experience in manufacturing emergency call systems of similar size and scope. c. All RF components must be labeled to comply with FCC Part 15. d. All RF components must be manufactured to ISO 9000 standards. 4. SCHEDULING It will be the responsibility of the contractor to coordinate all work with other trades for scheduling, rough-in, and finishing all work as required. The owner will not be liable for any costs due to missed dates or poor coordination of the supplying contractor with other trades. Filename: A&EWirelessSpec doc

3 5. WARRANTY The warranty will include all necessary equipment and labor to maintain the system in full working order for a period of one year from date of acceptance. Contractor shall maintain a service department, spare parts, telephone answering services and call dispatching to meet the following service standards: a. Routine Service Respond within 4 business hours (8 AM to 5 PM, Monday through Friday excluding holidays). Routine service is defined as a minor failure of a peripheral device such as a transmitter, which normally affects one resident or room. b. Emergency Service Respond within 2 hours of notification, 24 hours a day, of any catastrophic failure of equipment, which renders the emergency call system inoperative. 6. MAINTENANCE Provide necessary spare parts. Utilizing facility provided broad-band internet access, factory will provide free software updates, online support and diagnostics upon request for two years from date of completion. Occupancy Adjustments: When requested within one year of acceptance, provide on-site assistance in adjusting controls and investigating possible need for any system revisions required to meet actual occupancy conditions. Provide up to three site visits for this purpose. 7. DEMONSTRATION AND TRAINING Provide factory authorized and trained service representative to demonstrate the system in all operating modes and functions and to train owner s personnel in system operation. Provide training of Owners personnel in operation and preventive maintenance of the system. Provide both classroom training and hands-on experience. Use approved operation and maintenance manual material as an instructional aid. Provide copies of this material for the use of instruction. Schedule training with owner with at least 7 days advance notice. 8. PRODUCTS The products provided shall be new and the standard product of a single reputable manufacturer. As a reference of quality, functionality and operation the equipment provided will meet or exceed all standards of the Heritage MedCall Sentry Freedom wireless emergency call system. All bids for equipment will demonstrate, at a minimum, the same quality and capabilities of the Sentry Freedom system. Filename: A&EWirelessSpec doc

4 9. Master Computer The Master Computer is the main control and annunciation point for the wireless emergency call system. a. The Master Computer shall be a Dell or equivalent PC equipped with a XVGA flat panel display. The system will have the option of touch panel operation and wall mounted display. b. Sentry Freedom software will be installed to communicate with, store, and display all system activity from the Network Coordinator. c. The computer will provide for network interface via LAN and/or telephone modem connection. d. A database will be maintained on this computer or networked computer for retrieval of all system activity. e. The Master Computer will be provided AC power by means of a suitable uninterruptible surge suppressed power supply. f. The master computer will have the following minimum specifications: Pentium IV or better at 2.8 GHz. Microsoft Windows XP Pro or subsequent version 4 GB of RAM DVD/CD-RW drive 6 USB 2.0 ports Dual 200 GB (minimum) internal hard-drive Microsoft mouse or compatible pointing device ASCII keyboard Sound card with speakers Network Interface Card VGA video output capable of 1024x768 resolution. g. The Master Computer shall be Heritage Model HM-PCW and the software Heritage Model HM-FR2-SW1, HM-FR2-SW2 or HM-FR2-SWN. 10. Master Computer Operation a. The computer and software shall be capable of sounding, displaying and logging a unique alarm when an emergency call is placed. b. The display will have the capability of listing the room number, registered occupants name, alarm time, type of call, location and contact information. c. The system shall be capable of monitoring and displaying check in devices to provide daily reporting of resident activity. d. The system shall be capable of reporting location for portable devices with one of two methods: Approximate zone level location. Approximate room level location. e. The computer will maintain supervision over the entire wireless system including infrastructure and transmission devices. Any low battery or device failures will be logged and annunciated on the screen. f. The system will have the ability to extend calls to telephones, wide area pagers, addresses, and voice over two-way radio utilizing LAN, telephone and serial communication. g. The software will maintain a database of all system activity and provide means of report generation for specific time periods, types of calls, rooms, and devices and printing or saving reports to specific files. h. The software will provide four levels of operation and administration based on unique passwords. i. The software will provide for displaying alarm information from other building systems via RS-232. These systems may include, and not limited to, fire panels, access control, building controls, nurse call systems and wander management systems. Filename: A&EWirelessSpec doc

5 j. The software will be capable of creating backup and restore disks in the event the master computer fails. k. Software and hardware shall be available to allow remote enrollment of transmitters and creating an import file for ease of adding large numbers of devices to an existing system without disruption. 11. Network Controller The Network Controller shall connect to the Master Computer and is the interface to the wireless network. The controller is a two-way radio device capable of receiving and transmitting information to the wireless network. a. The controller shall receive and convert radio transmissions from registered wireless devices to serial data for receipt by the Master Computer b. The controller shall receive serial data from the Master Computer and convert it for radio transmission to the wireless network and registered devices. c. The controller shall be provided with an interconnect cable and power supply. The power supply will receive its power from the same uninterruptible surge suppressed power supply as the Master Computer. d. The Network Controller will be Heritage model HM-6040 for zone level location of portable devices. e. The Network Controller will be Heritage model HM-6080 for room level location of portable devices. 12. High-Power Repeater The High-Power Repeater shall provide range extension and location information from wireless transmitters registered to the system. a. The repeater will be provided power by means of an AC adapter with output suitable for class 2 wiring to the repeater. b. The repeater will contain a lithium-ion battery for battery backup and be of sufficient capacity to provide 24 hours of normal operation. c. Suitable weatherproof enclosures will be available to allow outdoor mounting. d. The High-Power Repeater will be Heritage Model HM-5040T. 13. Transmitters Battery Powered All transmitters will be provided with batteries and replacement batteries must be commercially available from standard retail electronics stores. All devices will be available with 3 minute or 60 minute check in times. The check in times will be dictated by the maximum number of devices in the completed system a. Water-Resistant Single Button Transmitter Transmitter shall be water resistant in normal use, including bathing. Transmitter shall be fully supervised and transmit low battery warnings. Transmitter shall use a single call button requiring a minimum one-second press to activate a call. The delay shall be for false alarm prevention. Transmitter shall include a visible LED to indicate transmission Transmitter shall have a reset button on the rear of the case, which may be utilized as a staff activated call clear. The transmitter shall not exceed 2.2 x 1.9 x 0.72 and a weight of 1.4 ounces. Transmitter shall be furnished with both a neck cord and belt clip. Transmitter will have available an optional wristband. The Water Resistant Single Button Transmitter will be Heritage Model HM-1223S. Filename: A&EWirelessSpec doc

6 b. Wireless Pull-cord Transmitter The pull-cord transmitter will be a single gang device, which may be surface-mounted or mounted to a suitable non-metallic single gang electrical box. 2-gang adapter plates shall allow for mounting to existing 2-gang mounts. The transmitter will operate from the pull cord or front mounted slide switch. The transmitter will have a visible LED to indicate transmission. The transmitter will be clearly marked with the word EMERGENCY. The transmitter shall be fully supervised and transmit low battery warnings. The transmitter will provide optically isolated connections for remote wired pull-cords and smoke detectors. The transmitter shall provide hook-up to light a dome lamp for input 1 and input 2 using a external 24 volt DC power supply. The Wireless Pull-cord Transmitter will be Heritage Model HM-W541Bxx. c. Wireless Single Patient Station The wireless single patient station shall be for use with remote call origination cordset A receptacle shall be provided to accept singe ¼ jack type cordsets. W41 backbox: 4-11/16 (11.91cm) square electrical box with one-gang adapter for total depth of 2-7/8 (7.30cm), The station shall be provided with red LED call placement indicator and white call cancel button. A call shall be originated if the cordset is removed from the receptacle. The face plate shall be finished in off-white. The wireless single patient station will be Heritage Model HM-WSPS. d. Universal Wireless Transmitter The universal wireless transmitter shall be capable of monitoring NO or NC dry contacts. The transmitter shall have screw terminals for connection to field wiring. The transmitter shall have a tamper switch to signal when the case has been compromised. The transmitter shall be fully supervised and transmit low battery warnings. The transmitter shall not be enclosed in a metallic electrical box. The transmitter shall be provided with a mounting bracket to ease installation. The transmitter shall not exceed 3.6 x 1.75 x.98 including bracket. The universal wireless transmitter will be Heritage Model HM e. Universal Door/Window Transmitter The Universal Door/Window transmitter shall be provided with an internal reed switch, actuating magnet and auxiliary input capable of monitoring NO or NC dry contacts. The transmitter shall have screw terminals for connection to field wiring. The transmitter shall have a tamper switch to signal when the case has been compromised. The transmitter shall be fully supervised and transmit low battery warnings. The transmitter shall not be enclosed in a metallic electrical box. The transmitter shall be provided with a mounting bracket to ease installation. The transmitter shall not exceed 3.6 x 1.75 x.98 including bracket. The universal door/window transmitter will be Heritage Model HM-1210W. f. Wireless Smoke Detector The Wireless Smoke Detector shall be a battery-powered, photoelectric smoke sensor use GE Interlogix CleanMe technology. Two 3V lithium batteries with an estimated operational life of five years shall provide power. The detector shall be fully supervised and transmit low battery warnings. The Wireless Smoke Detector shall be Heritage Model HM Filename: A&EWirelessSpec doc

7 g. Wireless Motion Detector The Wireless Motion Detector shall be a battery powered passive infrared detector. The detector shall feature pet immunity for animals to 30 lbs. The detector shall have a tamper switch to signal when the case has been compromised. A 3V lithium battery with an estimated operational life of two years shall provide power. The Wireless Motion Detector shall be Heritage Model HM Transmitters Building Powered The following transmitters are powered by a suitable 12 VDC power supply to reduce the requirement for battery replacement. a. Wireless Pull-cord Transmitter Normally Open The pull-cord transmitter will be a single gang device, which may be surface-mounted or mounted to a suitable non-metallic single gang electrical box. 2-gang adapter plates shall allow for mounting to existing 2-gang mounts. The transmitter will operate from the pull cord or front mounted slide switch. The transmitter will have a visible LED to indicate transmission. The transmitter will be clearly marked with the word EMERGENCY. The transmitter shall be fully supervised. The transmitter will provide optically isolated connections for remote wired pull-cords and smoke detectors providing Normally Open contacts The Wireless Pull-cord transmitter shall be Heritage Model HM-W541ROx b. Wireless Pull-cord Transmitter Normally Closed The pull-cord transmitter will be a single gang device, which may be surface-mounted or mounted to a suitable non-metallic single gang electrical box. 2-gang adapter plates shall allow for mounting to existing 2-gang mounts. The transmitter will operate from the pull cord or front mounted slide switch. The transmitter will have a visible LED to indicate transmission. The transmitter will be clearly marked with the word EMERGENCY. The transmitter shall be fully supervised. The transmitter will provide optically isolated connections for remote wired pull-cords and smoke detectors providing Normally Closed contacts to offer connected device supervision. The transmitter will provide LED drive for remote pull-cords for call placed verification. The Wireless Pull-cord transmitter shall be Heritage Model HM-W541RCx 15. Call Accessories a. 8 Pushbutton Call Cord The call cord shall be 8 polyvinyl cord. The call cord shall provide one momentary-contact push button and shall be encased in a molded, shock-proof plastic shell. The call cord shall use connector 1/4 style jack. The call cord shall be Heritage Model HM-PBCC-8 b. 2-1 Call cord adapter The call cord adapter shall be used to plug two call cords in one 1/4 jack. The call cord adapter shall have one male 1/4" jack and two female 1/4" jacks. The call cord adapter shall be Heritage model HM-ADO10 Filename: A&EWirelessSpec doc

8 16. Annunciation a. 1 Color Dome Light The dome light shall contain a bulb with a translucent plastic cover mounted on a two (2) gang, plastic faceplate. The white cover shall be removable without the use of tools and the bulb shall be bayonet mount to allow for easy bulb replacement. The bulb shall be white color. The 1 Color Dome Light shall be Heritage model HM-DM1. b. 2 Color Dome Light The dome light shall contain a bulb with a translucent plastic cover mounted on a two (2) gang, plastic faceplate. The white cover shall be removable without the use of tools and the bulb shall be bayonet mount to allow for easy bulb replacement. One bulb shall be white color and the second bulb shall be red. The 2 Color Dome Light shall be Heritage model HM-DM2. c. 4 Color Dome Light The 4 Color Dome Lamp, shall be surface, wall or ceiling mounted available for use as a 4 section dome lamp. The 4 Color Dome Lamp shall be UL and CUL listed Hospital Signaling Equipment / Nurse Call Equipment. The lamps shall be Bayonet type, long life incandescent lamps rated at 70 ma at 24 volts DC each, replaceable from the front. The 4 Color Dome Lamp shall use prewired connectors to facilitate easy installation and mount using only the four screws provided. The base shall be Flame-retardant UL 94V-O off white color. The dome lens shall be flame-retardant translucent polycarbonate plastic for the amber, green and red lens. The white lens shall be of flame-retardant translucent polystyrene plastic. The 4 Color Dome Light shall be Heritage Model HM-DM4. d. LED Dome Light The LED Dome Light shall use a translucent plastic lens mounted on a flame retardant plastic base panel. The LED Dome Light shall provide four LED s, two White and two Red. The LED Dome Light shall use standard mounting base plate to accommodate both one and two gang mounting options. The LED Dome Light shall be Heritage Model HM-LI382LED e. Marquis Display The Marquis Display shall be able to receive between the frequencies of MHz using a POCSAG code format. The Marquis Display shall display RED LED characters of 3 3/4 tall in single line mode and 2 tall in two-line mode. The Marquis Display shall be equipped with internal AC power supply with cable and 2 prong plug. The Marquis Display shall be Heritage Model HM-660. f. Paging Transmitter The Paging Transmitter shall be capable of transmitting between the frequencies of MHz. The paging transmitter shall be equipped with power supply external at 12 VDC at 2 Amps that requires an 110 VAC outlet. The paging transmitter shall transmit required alphanumeric information to pagers. The paging transmitter shall be model HM-651. g. Pagers The pagers shall be capable of displaying alphanumeric messages from paging transmitter. The pager shall be Heritage model HM-658. Filename: A&EWirelessSpec doc

Architectural and Engineering Specification for a. Flash / Flare

Architectural and Engineering Specification for a. Flash / Flare Architectural and Engineering Specification for a Flash / Flare June 27, 2014 Page 1 of 12 T1DA0115-001 Rev D This document is intended to provide performance specifications and operational requirements

More information

Architectural and Engineering Specification for a Real-Time Locating System Flare

Architectural and Engineering Specification for a Real-Time Locating System Flare Architectural and Engineering Specification for a Flare AE-T1-IN-R3-E-0617 Page 1 of 14 This document is intended to provide performance specifications and operational requirements for the Flare. It is

More information

Hugs Product Guide Specification

Hugs Product Guide Specification Stanley Healthcare Solutions 309 Legget Drive Ottawa, ON K2K 3A3, Canada Tel: 1.866.559-6275 Int l: +1 (613) 592.6997 Fax: (613) 592.4296 Web site: www.stanleyhealthcare.com E-mail: hugssupport@stanleyworks.com

More information

Tek-CARE 500 Wireless Nurse Call System

Tek-CARE 500 Wireless Nurse Call System Tek-CARE 500 Wireless Nurse Call System UL 2560 Listed Submittal Package as of 11/13/2017 Phone: 828.524.9967 Toll-Free: 800.327.8466 Sales: Option 2 Tech Support: Option 3 324 Industrial Park Road Franklin,

More information

SECTION NURSE CALL SYSTEM

SECTION NURSE CALL SYSTEM NURSE CALL SMARTCARE NURSE CALL SOLUTION Architectural Specifications Part 1 General SECTION 275223 - NURSE CALL SYSTEM 1.0 Summary 1.1 This section includes nurse call system and requirements for system

More information

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2 Architectural & Engineering Specifications Control Panel 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality assurance...

More information

ERS-3600B. PERS-3600B Personal Emergency Reporting System

ERS-3600B. PERS-3600B Personal Emergency Reporting System PERS-3600B Personal Emergency Reporting System ERS-3600B A Complete Emergency System For Comprehensive Care The Linear PERS-3600B includes a built-in speakerphone and reminder message capability, providing

More information

SMARTWALK DEMENTIA WANDERING SYSTEM

SMARTWALK DEMENTIA WANDERING SYSTEM A division of NESS CORPORATION PTY LTD SMARTWALK DEMENTIA WANDERING SYSTEM SWD Door Responder SWD Resonator SWD-PET (Sold Separately) SWD-PET-BAND (Sold Separately) INSTALLATION MANUAL 1. CONTENTS 1. CONTENTS...1

More information

Tek-CARE 500 Wireless Nurse Call System

Tek-CARE 500 Wireless Nurse Call System Tek-CARE 500 Wireless Nurse Call System UL 2560 Listed Submittal Package as of 1/31/2018 Phone: 828.524.9967 Toll-Free: 800.327.8466 Sales: Option 2 Tech Support: Option 3 324 Industrial Park Road Franklin,

More information

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions. 11/16/12 TerraView First Revision No. 15-NFPA 720-2012 [ Global Input ] Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

More information

Section PERIMETER SECURITY SYSTEMS

Section PERIMETER SECURITY SYSTEMS Section 28 16 43 PERIMETER SECURITY SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Provide and install a perimeter security system as herein specified for the purpose of detecting entry into a designated security

More information

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

PALS 9000 Personal Alarm Locating System System Specifications

PALS 9000 Personal Alarm Locating System System Specifications PALS 9000 Personal Alarm Locating System System Specifications NOTE: THIS SPECIFICATION IS BEING PROVIDED TO YOU FOR INFORMATIONAL PURPOSES ONLY. This sample documentation is provided AS IS without warranty

More information

AIRPORTS. CARECALLER PowerfulSecuritySolutionsForSeriousSecurityNeeds

AIRPORTS. CARECALLER PowerfulSecuritySolutionsForSeriousSecurityNeeds AIRPORTS CARECALLER PowerfulSecuritySolutionsForSeriousSecurityNeeds CARECALLER CARECALLER Emergency Call Systems are perfect for any Airport that is concerned with the safety and security of their employees.

More information

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi 50 (P/N 10-071) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system.

More information

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor A1UL PERS Personal Emergency Response System TABLE OF CONTENTS 1. READ THIS FIRST... 1 2. SYSTEM OVERVIEW.. 1 3. COMPONENTS 2 4. UNIT OPERATION! Standby Mode.. 3! Emergency Activation. 3! Answering Incoming

More information

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R Region Project Page 1 PART 1 - GENERAL 1.1 REFERENCES.1 CAN/ULC-S524-2006, Standard for the Installation of Fire Alarm Systems..2 CAN/ULC-S525-2007, Audible Signal Device for Fire Alarm Systems..3 CAN/ULC-S526-2007,

More information

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM SECURITY ACCESS AND SURVEILLANCE SECTION 13850 VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM ADEMCO Group 165 Eileen Way Syosset, New York 11791 1-800-645-7568 SECTION 13850 DETECTION

More information

SECTION INTRUSION DETECTION

SECTION INTRUSION DETECTION (NOTE TO DESIGNER: These Specifications are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer.) SECTION 28 16 00 INTRUSION

More information

Clino Guard. Intelligent Life Care. Solutions for safe and efficient care

Clino Guard. Intelligent Life Care. Solutions for safe and efficient care Clino Guard Intelligent Life Care Solutions for safe and efficient care Clino Guard more time for excellent care Rising costs, staff shortages and an aging society are just three of the many reasons why

More information

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description TrueCom Building Communications Systems 5115-Series 5115-9001, -9002 Area of Rescue Communications System Description The Simplex 5115-9001 and -9002 Area of Rescue Communications System provides buildings

More information

PALS ATLAS Personal Alarm Locating System. System Specifications

PALS ATLAS Personal Alarm Locating System. System Specifications PALS ATLAS Personal Alarm Locating System System Specifications 2017 NOTE: THIS SPECIFICATION IS BEING PROVIDED TO YOU FOR INFORMATIONAL PURPOSES ONLY. This sample documentation is provided AS IS without

More information

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

Rancho Cucamonga Fire Protection District Prevention Bureau Standard Rancho Cucamonga Fire Protection District Prevention Bureau Standard Title: Fire Alarm and Monitoring Systems Standard # 9-3 Effective: May 2002 Number of Pages: 7 Updated: December 2016 for consistency

More information

CM800 Emergency Call System

CM800 Emergency Call System Submittal Package as of 5/25/2017 Phone: 828.524.9967 Toll-Free: 800.327.8466 Sales: Option 2 Tech Support: Option 3 324 Industrial Park Road Franklin, NC 28734 tektone@tektone.net Fax: 828.524.9968 Copyright

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

Tek-CARE NC110, NC110A Nurse Call System

Tek-CARE NC110, NC110A Nurse Call System Tek-CARE NC110, NC110A Nurse Call System Submittal Package as of 5/25/2017 Phone: 828.524.9967 Toll-Free: 800.327.8466 Sales: Option 2 Tech Support: Option 3 324 Industrial Park Road Franklin, NC 28734

More information

UBC Technical Guidelines Section Edition Access Control Page 1 of 5

UBC Technical Guidelines Section Edition Access Control Page 1 of 5 Page 1 of 5 1.0 GENERAL 1.1 Related UBC Guidelines.1 Section 28 05 00 Access Services: General Standards.2 Section 08 71 00 Door Hardware 1.2 Coordination Requirements.1 UBC Access Services 1.3 Description.1

More information

WIRELESS SOLUTIONS FOR RESIDENCES. A Group brand

WIRELESS SOLUTIONS FOR RESIDENCES. A Group brand WIRELESS SOLUTIONS FOR RESIDENCES A Group brand WIRELESS TECHNOLOGY RELIABLE AND SAFE 2 TREX Wireless call system >page 04 D-POS Wandering alarm system >page 08 WALL Wall mounted calling devices >page

More information

SENTRY PRODUCTS, INC. 01/98 SCAN - STAND-ALONE - Sample Specification

SENTRY PRODUCTS, INC. 01/98 SCAN - STAND-ALONE - Sample Specification This sample specification is for a duress only stand-alone SCAN system using SR series receivers with zone-within-a-zone and graphic display. SECTION 17 DURESS SYSTEM PART 1.00 - GENERAL 1.01 DESCRIPTION

More information

STANDARD FEATURES SPECIFICATIONS

STANDARD FEATURES SPECIFICATIONS MAG LOCK P/N 300768 STANDARD FEATURES Holding Force: 1500 lbs.(675 Kg.) Easy Installation: Versatile mounting bracket for new and existing doors and frames. Sensor: Built-in Hall effect crystal affected

More information

Integrated Security Solutions

Integrated Security Solutions Integrated Security Solutions Table of Contents Control Panels 4 Keypads 8 Communication Modules 16 I/O Expanders 20 Door Control 24 Home Automation 25 RF Receivers 26 3 Our integrated security solutions

More information

Tek-CARE 120. Nurse Call System. Submittal Package. as of 11/13/2017

Tek-CARE 120. Nurse Call System. Submittal Package.  as of 11/13/2017 Tek-CARE 120 Nurse Call System Submittal Package as of 11/13/2017 Phone: 828.524.9967 Toll-Free: 800.327.8466 Sales: Option 2 Tech Support: Option 3 324 Industrial Park Road Franklin, NC 28734 tektone@tektone.net

More information

wireless. web-based. worthy of the name RACO.

wireless. web-based. worthy of the name RACO. wireless. web-based. worthy of the name RACO. reliable monitoring unequalled accessibility on-demand reporting wireless, web-based alarm detection and notification system from RACO designed specifically

More information

PROJ. NO SECTION PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS

PROJ. NO SECTION PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS SECTION 26 92 50 PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-27 41 00.00 10 (April 2006) -------------------------------- Preparing Activity: USACE Superseding UFGS-27 41 00.00 10 (November 2002) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS PERS-600 PERSONAL EMERGENCY REPORTING SYSTEM BY BY INSTALLATION & OPERATION INSTRUCTIONS (760) 8-7000 USA & Canada (800) -587 & (800) 9-0 Toll Free FAX (800) 68-0 www.linearcorp.com CONTENTS CONTROL AREA

More information

Data Center. Cold Storage

Data Center. Cold Storage Sensaphone Monitoring Systems Accessories & Sensors SCADA 3000 Sensaphone 2800 & Wireless Sensors IMS Wireless Node & Sensors IMS Data Center IMS WIRELESS SOLUTION Cold Storage Communications Closet Data

More information

Austin Independent School District Police Department Policy and Procedure Manual

Austin Independent School District Police Department Policy and Procedure Manual Policy 8.07 Austin Independent School District Police Department Policy and Procedure Manual Life Safety Systems I. POLICY The proper operations of the AISD Life Safety Systems (LSS) are essential for

More information

Tek-CARE NC150, NC200 Nurse Call System

Tek-CARE NC150, NC200 Nurse Call System Tek-CARE NC150, NC200 Nurse Call System Submittal Package as of 7/5/2017 Phone: 828.524.9967 Toll-Free: 800.327.8466 Sales: Option 2 Tech Support: Option 3 324 Industrial Park Road Franklin, NC 28734 tektone@tektone.net

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications.

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications. Wireless Sensors Security unplugged Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications. Wireless sensing technology to secure what matters most Designed

More information

Wireless for Commercial Security

Wireless for Commercial Security Wireless for Commercial Security For commercial buildings and campus-based coverage, Inovonics wireless intrusion detection devices, panic alarms and scalable network integrates easily into access control,

More information

Independent Living without Leaving Home. Personal Emergency Reporting Systems from Linear

Independent Living without Leaving Home. Personal Emergency Reporting Systems from Linear Independent Living without Leaving Home Personal Emergency Reporting Systems from Linear Connected and Reliable You can live in your own home independently, safe, secure and free from worry. Assistance

More information

1.3 REFERENCE STANDARDS

1.3 REFERENCE STANDARDS SECTION 28 4600 FIRE DETECTION AND ALARM PART 1 -GENERAL 1.1 SECTION INCLUDES A. Fire alarm system design and installation, including all components, wiring, and conduit. B. Circuits from protected premises

More information

OJD ITB No Attachment E Duress Alarm Equipment Specifications

OJD ITB No Attachment E Duress Alarm Equipment Specifications Duress Alarm Equipment Specifications PART 1 GENERAL 1.1 SECTION INCLUDES A. Duress devices. B. Alarm control panel. C. Signaling devices. 1.2 REFERENCE STANDARDS A. NFPA 70 - National Electrical Code;

More information

Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty...

Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty... Table of Contents Preface 1 Notice... 1 Trademarks... 1 US Patent Numbers... 1 Technical Services Contact Information... 2 Document Conventions... 2 Warranty... 2 Chapter 1 Radius Overview 6 1.1 About

More information

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS PART 1 GENERAL 1.1 SECTION INCLUDES A. Fire alarm and smoke detection systems 1.2 REFERENCES A. NFPA 72 B. NFPA 101 1.3 REGULATORY REQUIREMENTS A. System: UL listed B. Conform to requirements of NFPA 101

More information

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

PRODUCT CATALOGUE.   Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg PRODUCT CATALOGUE Cape Town 18 Darter Road Blue Water Estate Kommetjie Luke Fowles - 076 161 8124 luke@providenttech.co.za Frank Fowles - 082 445 1541 frank@providenttech.co.za www.providenttech.co.za

More information

CRIME. Manufacturing And Minor Inventions CRIME. Control Room Integrated Monitoring Environment

CRIME. Manufacturing And Minor Inventions CRIME. Control Room Integrated Monitoring Environment Control Room Integrated Monitoring Environment INDEX 1. Requirements for software. 2. Installation Instructions. 3. How to Register your Software. 4. Start Using... 5. Operating Instructions. 6. Screen

More information

Quick Alert Remote (QA216R)

Quick Alert Remote (QA216R) Quick Alert Remote (QA216R) Description The QA 216 Remote is used by AT&T to monitor tower lights and turned down facilities. It is a 16-bit alarm unit used to transport discrete alarms from a remote location

More information

DS7400Xi Addressable Control/ Communicator

DS7400Xi Addressable Control/ Communicator DS7400Xi Addressable Control/ Communicator DS7400Xi DS7400Xi-EXP 110VAC operation 220VAC operation Remotely Programmable WDSRP (Windows Detection Systems Remote Programming Software), allows the systems

More information

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 28 3111 DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Manual fire-alarm boxes. 3. System smoke detectors. 4. Heat detectors.

More information

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM SECURITY ACCESS AND SURVEILLANCE SECTION 13850 VISTA 250FBP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM ADEMCO Group 165 Eileen Way Syosset, New York 11791 1-800-645-7568 SECTION 13850 DETECTION

More information

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM SECURITY ACCESS AND SURVEILLANCE SECTION 13850 VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM ADEMCO Group 165 Eileen Way Syosset, New York 11791 1-800-645-7568 SECTION 13850 DETECTION

More information

SECTION LIGHTING CONTROLS

SECTION LIGHTING CONTROLS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 09 23 LIGHTING CONTROLS SPEC WRITER NOTE: 1. Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming. SECTION 260943 SPECIFICATIONS - Wireless Network Lighting Controls. PART 1 - GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY AND KEY SYSTEM DIFFERENTIATORS A. The lighting control system specified herein shall

More information

Control/Communicator

Control/Communicator Architectural & Engineering Specifications Control/Communicator 1.0 GENERAL... 2 1.1 SCOPE OF WORK... 2 1.1.1 Introduction... 2 1.2 GENERAL CONDITIONS... 2 1.2.1 After-Sales Support... 2 1.2.2 Quality

More information

Offer your customers a high end solution for a low end price. Complete alarmsystem with integrated 24/7 camera surveillance Immediate Push Alarm on mobile phone including photo and video-recording Camera

More information

Wireless Devices. This chapter introduces the suite of DSC wireless sensors and devices used with the Impassa and other series of DSC alarm systems

Wireless Devices. This chapter introduces the suite of DSC wireless sensors and devices used with the Impassa and other series of DSC alarm systems Wireless Devices This chapter introduces the suite of DSC wireless sensors and devices used with the Impassa and other series of DSC alarm systems ALARM DETECTORS WS4945 DOOR/WINDOW SENSOR The WS4945 is

More information

ONYX FirstVision Specification Interactive Firefighters Display

ONYX FirstVision Specification Interactive Firefighters Display ONYX FirstVision Specification Interactive Firefighters Display NOTIFIER is a registered trademark, and ONYX FirstVision, NOTI FIRE NET, and VeriFire are trademarks of Honeywell International Inc. Microsoft

More information

MiNi Server environment MoNitoriNg SySteM

MiNi Server environment MoNitoriNg SySteM enviromux-mini with enviromux-t-3 temperature Sensor Features & Applications Monitors threats: temperature Humidity Water Leakage intrusion The ENVIROMUX Mini Server Environment Monitoring System monitors

More information

SECTION HEALTHCARE COMMUNICATION AND MONITORING SYSTEM (NURSE CALL)

SECTION HEALTHCARE COMMUNICATION AND MONITORING SYSTEM (NURSE CALL) SECTION 27 52 23 HEALTHCARE COMMUNICATION AND MONITORING SYSTEM (NURSE CALL) PART 1 - GENERAL 1.1 SECTION INCLUDES A. Basic System Requirements B. Stations C. Master Stations/Consoles D. Annunciators,

More information

Protect anything, anywhere, anytime.

Protect anything, anywhere, anytime. Set-up Guide Protect anything, anywhere, anytime. cell burst Built-in Features www.tattletalealarm.com ALARM SYSTEM IN A BOX 1.2 watt Cellemetry radio PIR motion 115 db Siren Safety strobe light Lighted

More information

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. Features of Monnit ALTA Sensors. General Description

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. Features of Monnit ALTA Sensors. General Description Wireless Thermocouple Sensors by The Leading Enterprise Internet of Things Solution General Description The ALTA Wireless Thermocouple Sensor is available with a hardwired thermocouple or K-type connector

More information

PRODUCT CATALOG. Concord Family Product Catalog. December 1999

PRODUCT CATALOG. Concord Family Product Catalog. December 1999 PRODUCT CATALOG Concord Family Product Catalog December 1999 Interactive Technologies, Inc. 2266 Second Street North, North Saint Paul, MN 55109 800/777-5484 www.itii.com CONTROL PANELS Concord Express

More information

Nurse Call Systems & Emergency Call Systems. Overview of ANSI/UL 1069 and ANSI/UL 2560

Nurse Call Systems & Emergency Call Systems. Overview of ANSI/UL 1069 and ANSI/UL 2560 Nurse Call Systems & Emergency Call Systems Overview of ANSI/UL 1069 and ANSI/UL 2560 The Association of Electrical and Overview National Consensus Standards American National Standards Institute (ANSI)

More information

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM DIVISION 26 ELECTRICAL SECTION 26 81 11 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install all equipment and accessories for a complete local, analog addressable, manually and automatically actuated,

More information

Unified Fire Authority - Fire Prevention Bureau

Unified Fire Authority - Fire Prevention Bureau Unified Fire Authority - Fire Prevention Bureau FIRE ALARM AND EMERGENCY COMMUNICATION SYSTEM RECORD OF COMPLETION To be completed by the system installation contractor at the time of system acceptance

More information

RFP Addendum 2 March 31, 2016

RFP Addendum 2 March 31, 2016 RFP Addendum 2 March 31, 2016 For Best Value Procurement Option Three Security Upgrades Ph 1 UT Health Science Center SBC No. 540/013-04-2015 This Addendum forms a part of the Request for Proposals (RFP)

More information

IL691 SECTION E Rev. 7-12/2003. Condensed Catalog Section E Healthcare Communications Systems

IL691 SECTION E Rev. 7-12/2003. Condensed Catalog Section E Healthcare Communications Systems IL691 SECTION E Rev. 7-12/2003 Condensed Catalog Section E Healthcare Communications Systems Alpha Communications 42 Central Drive Farmingdale, NY 11735-1202 Phone: (631) 777-5500 Fax: (631) 777-5599 Website:

More information

Wireless Sensors. Security anywhere. Interlogix wireless sensors deliver highly accurate detection and easy installation for multiple applications.

Wireless Sensors. Security anywhere. Interlogix wireless sensors deliver highly accurate detection and easy installation for multiple applications. Wireless Sensors Security anywhere Interlogix wireless sensors deliver highly accurate detection and easy installation for multiple applications. Wireless sensing technology to effectively secure the most

More information

INDUSTRIALMANDOWN & LONEWORKER

INDUSTRIALMANDOWN & LONEWORKER INDUSTRIALMANDOWN & LONEWORKER PowerfulSecuritySolutionsForSeriousSecurityNeeds Emergency Call Systems are perfect for any company that is concerned with the safety and security of their employees. Our

More information

Video Surveillance Systems Infrastructure

Video Surveillance Systems Infrastructure DIVISION 28 ELECTRONIC SAFETY AND SECURITY JVC Professional Products Company Division of JVC AMERICAS CORP. 1700 Valley Road Wayne, New Jersey 07470 (800) 582-5825 www.jvc.com/pro This product specification

More information

status AW1 Plus WiFi Alarm System User Manual

status AW1 Plus WiFi Alarm System User Manual status AW1 Plus WiFi Alarm System User Manual Foreword Congratulations on your purchase of the AW1 Plus Alarm system. Before you commence installation we recommend that you unpack the product, familiarise

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

Product Specification

Product Specification Southwest Microwave, Inc. 9055 S. McKemy Street Tempe, Arizona 85284 USA (480) 783-0201 Fax (480) 783-0401 Product Specification INTREPID MicroTrack Buried Cable Perimeter Intrusion Detection System System

More information

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition

Architect s Project Number of 12 Fire Alarm/Smoke Detection Systems District Master Specs 2013 Edition PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 28 31 00 FIRE ALARM AND SMOKE DETECTION SYSTEMS A. Fire alarm and smoke detection systems 1.2 REFERENCES A. NFPA 72 B. NFPA 101 1.3 REGULATORY REQUIREMENTS A.

More information

Panel XTO210/610/710 GPRS

Panel XTO210/610/710 GPRS P r o d u c t S p e c i f i c a t i o n s S h e e t Doc. - Ref. 220-XTO Version : Juin 2013 Description Supervised Wireless Technology The XTO control panel is a Videofied weatherproof, wireless, battery

More information

UNC100 Integra Manual

UNC100 Integra Manual UNC100 Integra Manual New Generation Building Security July 30, 2014 V1.2 Copyright Notice Copyright 1995-2014 by All rights reserved Worldwide. Printed in Canada. This publication has been provided pursuant

More information

FIRE DEPARTMENT 9 METROTECH CENTER BROOKLYN, N.Y

FIRE DEPARTMENT 9 METROTECH CENTER BROOKLYN, N.Y dige of FIRE DEPARTMENT 9 METROTECH CENTER BROOKLYN, N.Y. 11201-3857 wew.vdertificate OF APPROVAL # 6167A (AMENDED) THIS CERTIFICATE IS REVOCABLE, NOT TRANSFERABLE and EXPIRES on OCTOBER 15, 2018 By order

More information

GE LightSweep Lighting Control System Guideform Specification

GE LightSweep Lighting Control System Guideform Specification GE Lighting Control GE LightSweep Lighting Control System Guideform Specification If you have any questions at all regarding this specification, please contact your local GE Lighting Control representative,

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

WIRELESS CONTROLS & DETECTORS

WIRELESS CONTROLS & DETECTORS WIRELESS CONTROLS & DETECTORS WLS908 Panic Pendant Press 2 buttons for 2 seconds to initiate a panic alarm Water-resistant Pendant test function Supervised for low battery Each pendant is a wireless zone

More information

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel Designed to integrate seamlessly with, access control, and ADEMCO s full range of fire and burglary components, the

More information

CARD ACCESS CONTROL SYSTEM

CARD ACCESS CONTROL SYSTEM SECTION 13851 CARD ACCESS CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: A complete, operable, tested, integrated proximity access control system, to operate on a proximity principle where

More information

Omniguard 4: Features

Omniguard 4: Features OMNIGUARD 4 The clear choice for monitoring and documenting Vacuum and Pressure in a containment area. Ideal for Asbestos, Lead and Mold abatement and Clean Room monitoring. Omniguard 4: Features The Omniguard

More information

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors. Fire Sentry Corporation (FSC) 593 Apollo Street Tel.: 714-671-1100 Brea, California 92821 Fax: 714-671-5821 Multi-Spectral, Digital, Infrared Electro-Optical FSC Model No. s FS10-R and FS10-A Unitized,

More information

Lake County / Multi-Department Storage Facility / Project / December 12, 2016 SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Lake County / Multi-Department Storage Facility / Project / December 12, 2016 SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 283111 A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to

More information

arm wire free solutions nurse call personal security fire alarms

arm wire free solutions nurse call personal security fire alarms arm nurse call personal security fire alarms arm introduction Radio alarm systems have been serving both the public and private care sector for over a decade. The advances in battery technology, manufacturing

More information

Mounting Plate ADA/HOSPITAL SIGNALING DEVICES 14-8 FEATURES. > Momentary switch push button > Stainless steel faceplate

Mounting Plate ADA/HOSPITAL SIGNALING DEVICES 14-8 FEATURES. > Momentary switch push button > Stainless steel faceplate Mounting Plate 147-10 > Momentary switch push button > Stainless steel faceplate The Edwards Cat. No. 147-10 Mounting Plate when used with the catalog series 620 Push Buttons (page 10-9) forms a convenient

More information

Description Supervised Wireless Technology PRODUCT SPECIFICATION SHEET

Description Supervised Wireless Technology PRODUCT SPECIFICATION SHEET PRODUCT SPECIFICATION SHEET Made by RSI VIDEO TECHNOLOGIES 2200-XLSP February 2012 Description is a Videofied wireless, battery operated security system. The control panel is designed for residential and

More information

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 Division 28 ELECTRONIC SAFETY AND SECURITY TABLE OF CONTENTS 28 0000 GENERAL... 2 A. DEFINITIONS...2 28 3111 DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 A. DESIGN REQUIREMENTS...2 B. CONSTRUCTION REQUIREMENTS...2

More information

Conventional Releasing Control Panel

Conventional Releasing Control Panel s Data Sheet Fire Safety Products Conventional Releasing Control Panel Pre-Action Deluge Agent-Releasing Fire System Model TXR-320 Remote configurable Up to two (2) hazard areas Operable with the following:

More information

IL691 Rev. 21-8/2017. Healthcare Communications Systems Catalog.

IL691 Rev. 21-8/2017. Healthcare Communications Systems Catalog. IL691 Rev. 21-8/2017 Healthcare Communications Systems Catalog Tek-BRIDGE Server Tek-CARE 120 Nurse Call System Tek-CARE 500 Wireless Nurse Call System Tek-CARE 300 II Nurse Call System Tek-CARE NC200

More information

STUDY AND TEST MATERIAL FOR THE. FA2 and FA4 ASSESSMENTS. (Fire Alarm On-Site and Business Cert. Holder) June 14, 2017

STUDY AND TEST MATERIAL FOR THE. FA2 and FA4 ASSESSMENTS. (Fire Alarm On-Site and Business Cert. Holder) June 14, 2017 STUDY AND TEST MATERIAL FOR THE FA2 and FA4 ASSESSMENTS (Fire Alarm On-Site and Business Cert. Holder) June 14, 2017 This document contains sample questions to help participants study for the FA2 and FA4

More information

good things in small packages

good things in small packages FireShield Control Panels good things in small packages life safety for small buildings and shops A perfect arrangement FireShield offers the very best conventional fire alarm technology available, with

More information

COMMISSION ORDER. IT IS FURTHER ORDERED that the Request for Bid and Notice to Bidders be displayed on the Franklin County website.

COMMISSION ORDER. IT IS FURTHER ORDERED that the Request for Bid and Notice to Bidders be displayed on the Franklin County website. 4.e STATE OF MISSOURI County of Franklin ss. COMMISSION ORDER Commission Order No. 2016-316 Third Quarter Term 2016 Tuesday,August,09,2016 Bid Notice IN THE MATTER OF ADVERTISING FOR SEALED BIDS FOR SMOKE

More information

NFPA 72 Code Changes vs 2013

NFPA 72 Code Changes vs 2013 NFPA 72 Code Changes - 2010 vs 2013 AFAA-NE Westborough, MA February 7, 2018 Richard Roux NFPA 72 National Fire Alarm and Signaling Code Overview and 2013 Changes NFPA 72 1993 Edition Aug 20, 1993 1996

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Minimum lighting control (base scope of work) shall include all corridors. The lighting in all the corridors shall be turned on (if not already on) if

More information

GARCIA GALUSKA DESOUSA Consulting Engineers

GARCIA GALUSKA DESOUSA Consulting Engineers L#57297 /Page 1/July 21, 2017 ELECTRICAL SYSTEMS NARRATIVE REPORT The following is the Electrical Systems narrative, which defines the scope of work and capacities of the Power and Lighting systems, as

More information