1 EDUCATION Bachelor of Science - Architectural Engineering Major in Building Electrical Power Systems Design Milwaukee School of Engineering, 2009 EXPERIENCE Ms. Blau joined Leedy & Petzold as a Project Manager in Spring She brings extensive experience to Leedy & Petzold on the development of projects from design through construction. Some of Ms. Blau's representative work is as follows: Johnson Controls Inc. Power Solutions Building Addition of 3 rd and 4 th floors, along with a mechanical penthouse, to existing Power Solution Building. The entire power solution building achieved LEED certification, continuing the Global Headquarters campus title of LEED-platinum certification. Project included expansion of existing power distribution and emergency systems. New construction space contained raised-floor systems, thus utilizing the Walkerflex modular power system containing both floor boxes and furniture-feed connections. Lighting design included LED and fluorescent technologies while being controlled with a complete Lutron eco-system program. The Lutron quantum lighting panels tied into the JCI campus Metasys monitoring system, providing the client with a completely monitored facility. An existing elevator was switched to emergency power and required detailed phasing of design. The project was drafted using Revit MEP and Navisworks software, providing the Owner with a coordinated 3D model at completion. Bio-Tech Lab and B-Qual. Provided complete electrical design for lab remodel. Designed custom infrastructure required for distribution of power and data systems. Remodeled lab spaces included a battery testing facility and quality control labs. Parking Lot Expansion and Flag Pole Lighting. Provided multiple lighting options and energy savings for expansion of visitor parking lot. Utilized 100-count LED fixtures and Lutron Ecosystem controls to expand LEED-certified campus lot. Flag pole lighting consisted of LED spotlighting with Lutron controls. Conference Room Lighting Plans. Designed general lighting plan for medium and large conference rooms for company-wide remodels. Included general lighting options and energy-saving control options that could easily be implemented in most office locations. Building #1 Lobby Renovation. Performed survey of existing conditions at Main campus headquarters building. Provided complete electrical design for new lobby space and kitchenette, including new security. Denver Branch Renovation, Littleton, CO. Summarized requirements to relocate existing electrical utility service and electrical room, and then designed construction plans which laid out phasing required to minimize company down-time to one day. Electrical design of new conference room and team/multi-purpose rooms. Provided new emergency egress lighting throughout
2 Cuna Mutual Group Back-up Electrical Power Generator, Waverly, Iowa. Designed integration of 480Y/277V, 3-phase, 1500kW diesel generator and (2) new interior closed-transition automatic transfer switches. Phasing was arranged for new transfer switches to back-feed existing switchboards. Lawrence University Stansbury Theatre Remodel & Courtyard build-out, Appleton, WI. Performed electrical design to update house lighting in theatre space and incorporate into existing lighting control system. Existing courtyard space finished to be used as rehearsal room, classroom, offices, and restrooms. New electrical systems required complete throughout build-out. Existing substation equipment required special attention as it was Kinney equipment, no longer eligible for manufacturer field-servicing. Thedacare Medical Office Building, Appleton, WI. Participated in the complete remodel of a team meeting building into a medical office building. Existing 240/120V, 200A service remained but new power, lighting, and systems were provided through-out. Electrical design was provided for new building use and mechanical/plumbing updates. Exterior lighting and controls were updated. MATC Biotech Lab in Madison, WI. Renovation and expansion of existing biotech lab spaces. Complete electrical power, lighting, fire, data, and sound systems design. Inefficient lighting was replaced with low-wattage fluorescent technology through-out lab and classroom spaces. University of Wisconsin Whitewater, Perkins Stadium. Replacement of existing football field lights and controls on new 80 and 110 tall poles. Utilized Musco lighting and control panels. Design included reusing existing underground conduits and running new feeders. Local controls panels were located near each of the new poles, which also contained new LED security lighting. PROFESSIONAL ORGANIZATION MEMBERSHIPS Illuminating Engineering Society of North America (IESNA) Society of Women Engineers (SWE) U.S. Green Building Council (USGBC) National Fire Protection Association (NFPA) Electrical League of Milwaukee - 2 -
3 Oshkosh Truck Electrical Distribution System Replacement and Lighting Restoration. Design provided electrical restoration of a house originally built in 1911 and converted to an art museum. The original 200A, 120/240V, 1-phase service and a more recent 240V grounded B service were replaced with a single 208Y/120V, 3-phase, 4-wire service. The existing equipment and loads were consolidated and replaced with modern electrical equipment. All existing wiring was traced and tested for safety and the respective panelboard directories were updated. Original period-style lighting fixtures were sent out for restoration. Existing pushbutton switches were replaced throughout with new pushbutton switches. Additional lighting track with specialty fixture heads were added to accent specific pieces of artwork. Extra care was required to analyze the construction of the building being that it was unique and built fire-resistant to protect the artwork, and some walls and floors were not able to be penetrated. University of Wisconsin Whitewater. Replacement of campus 25 kv and 5kV substation equipment including two 7500 kva transformers, circuit breaker switchgear, capacitor banks, and related cable connections supplying electrical service to the campus. New equipment includes a four-bay lineup of metal-enclosed, medium voltage, air interrupter switchgear, two pad-mounted transformers, and two seven-bay lineups of metal-clad, circuit breaker distribution switchgear with weatherproof house. The existing substation service is being maintained until the new switchgear is installed and ready for switchover. University of Wisconsin Whitewater. Performed electrical engineering design for an addition and remodeling for the Student Union. Effort involved relocating the 4.16kV primary loop, ductbanks, and manholes serving the campus. University of Wisconsin Parkside. Provided electrical engineering design for an addition and remodeling for the Student Union. Design included the replacement of the existing service, phasing the work so the existing building facilities could remain operational during construction, adding emergency power and generator, and extending existing 4.16kV primary loop to new main switchboard. Wisconsin Energy Conservation Corporation, Madison, WI. Participated in the design of a 32,000 sq. ft. LEED Gold office building. A 0.9 watts per square foot lighting power density was achieved and advanced daylighting controls were integrated. Blood Center of Southeastern Wisconsin, Milwaukee, WI. Building addition and remodeling of lab space which included the integration of several zone UPS systems and emergency generator upgrades for state-of-the-art laboratories. Presented design alternatives with cost implications to the Owners. Construction was performed in phases which required additional supervision and coordination with the Owner s representative and the construction manager to resolve issues and keep the project on track. Washington County Courthouse, West Bend, WI. This project consisted of a three-story addition between the existing courthouse and jail buildings, the renovation of the existing courthouse, and the addition of seven new courtrooms. Underfloor raceways were designed to accommodate the A/V systems. The automated courtroom accessories systems are designed to utilize a touch-screen. Specialty systems included building-wide public address systems, door controls, duress alarms, communications, camera systems, power infrastructure, and low voltage lighting controls all compatible with the building head end equipment and A/V system
4 Turner Hall, Milwaukee, WI. Designed electrical infrastructure upgrade and partial restoration of the Ballroom which was built circa The service to this building was upgraded and provisions were incorporated for future kitchen, stage power, ballroom lighting, and theatrical dimming systems. SBC/Ameritech Central Office Buildings. Performed engineering for electrical upgrades to several buildings including an increase in the service size, replacement of existing switchgear and panelboards, and the addition of a new engine generator. These buildings had extensive internal building grounding and exterior grounding rings. St. Michael s Hospital, Milwaukee, WI. Participated in design of renovation of operating rooms, nuclear medicine, mammography, and radiology. YMCA, Wauwatosa, WI. Provided electrical engineering for renovation of existing YMCA. The project entailed the demolition of the existing basketball courts, elevated running track, and office space. This made way for larger, expanded open workout spaces, a new running track, lobby, multi-purpose rooms, break room, and offices. Lakeview Medical Center, Rice Lake, WI. Renovation and expansion of the Dialysis Department and several new patient rooms with improved lighting, power, and special systems. Waukesha Memorial Hospital, Waukesha, WI Four new operating rooms and renovation of four existing operating rooms. Involvement in this project included very detailed survey work of the existing operating rooms and design of a room s power using isolation panelboards and a central uninterruptible power supply. Project included design of a lighting layout which fit with the surgeons desires for lighting flexibility during a procedure. Intelligent low voltage controls were used and work was coordinated with the Infection Control Department at the hospital to ensure the fixtures selected fit their criteria for cleaning. Electrical infrastructure upgrade to support hospital addition consisting of new service and distribution including the installation of two new 5000 kva transformers, two new emergency diesel generators, and coordination of existing systems. New 6-floor addition including a new Emergency Department, LDR rooms, rooftop Helipad and design of electrical room and telecommunications room. These were designed to be stacked and located to minimize longer power and data runs. The addition included the design of nurse call and patient monitoring systems. New G. I. Suite. American Medical Buildings Various Locations Danvers, MA 125,000 square foot medical office building including an ambulatory surgery center, imaging suite, and four operating rooms. This project was fast-tracked and special care was taken to ensure that the design and construction requirements were properly coordinated. Intense coordination took place with local power company to accommodate the large electrical requirements - this building required a 4000A secondary service. Several additional suites were built-out through different phases of the project including a kitchen, pediatrics suite, internal medicine, and a two MRI imaging suite
5 Danville, KY Shell building and 32,000 square foot ambulatory surgery center build-out. The ambulatory surgery center contained four operating rooms. Pewaukee, WI 16,000 square foot ambulatory surgery center converted from a 4-tenant suite building. There were two operating rooms under the current design; however, provisions were made for an additional two operating rooms for the future. Design for an imaging suite and MRI machine was included as part of this building. An emergency power generator was added to the building to accommodate the medical occupancy
JAMES R. HAUG. Representative projects that Mr. Haug has been involved with are as follows:
EDUCATION Bachelor of Science - Electrical Engineering University of Wisconsin - Milwaukee, 1986 EXPERIENCE Mr. Haug offers extensive engineering and management experience, assuring success in our client
More informationBrown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA
PART 1 - GENERAL 1.1 Background SECTION 26 00 10- ELECTRICAL DESIGN CRITERIA A. Brown University maintains it own campus electrical distribution system which serves the majority of the buildings and facilities
More informationELECTRICAL POWER SYSTEMS
Scope The various Codes applicable to the University's electrical power system are mainly based upon a model of a single utility service, connected to a single premise. The University s electrical system,
More informationElement D Services Electrical
PART 1 - GENERAL 1.01 OVERVIEW A. This Section includes design standards and requirements for electrical service and distribution. This is a design standard and is not intended to be used as a Specification.
More informationBuilding Electrical System Overview
Philip Mackey L/E Dr. Mistrick Holy Cross Hospital North Addition Silver Spring, MD 0/3/05 Building Electrical System Overview Executive Summary: The following report describes the existing emergency power
More informationDESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES
2.07 ELECTRICAL GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.07 It is expected that the electrical design professional will conform to accepted good engineering design practices.
More informationRelated Sections: TBD. Effective Date: January 1, 2016
Description: The purpose of the section is to highlight the current applicable UMCP Design Standards for the design, selection and, installation of lighting fixtures within buildings. Related Sections:
More informationDivision 26 ELECTRICAL TABLE OF CONTENTS
Division 26 ELECTRICAL TABLE OF CONTENTS 26 1000 GENERAL... 33 A. CODE... 3 B. RELATED SECTIONS... 3 C. ABBREVIATIONS... 3 D. DEFINITIONS... 3 E. DRAWING REQUIREMENTS... 3 F. EQUIPMENT SERVICE ACCESS AND
More informationDuke University Medical School. Duke School of Nursing
Duke School of Nursing Lighting and Electrical Depth Proposal and Breadth Topics Proposal for Spring 2008 Semester December 18 th, 2007 Table of Contents Executive Summary....................................
More informationElectrical Design Guidelines Table of Contents
C: Compliant Rev. 3 Dated June 13 11 NC: Non-Compliant NA: Not Applicable Page1 16.1 General 16.2 Single Line Diagrams 16.3 Electric Motor Equipment and Controls 16.4 Lighting 16.5 Emergency Lighting 16.6
More informationCorbin Building. Technical Assignment 2. Matthew Trethaway Lighting/ Electrical AE 481W 10/26/2011 Advisor: Ted Dannerth
Corbin Building Technical Assignment 2 Matthew Trethaway Lighting/ Electrical AE 481W 10/26/2011 Advisor: Ted Dannerth 10/26/2011 Technical Report II 1 Executive Summary The following report is an overview
More informationGARCIA GALUSKA DESOUSA Consulting Engineers
L#57297 /Page 1/July 21, 2017 ELECTRICAL SYSTEMS NARRATIVE REPORT The following is the Electrical Systems narrative, which defines the scope of work and capacities of the Power and Lighting systems, as
More informationELECTRIC SERVICE EVALUATIONS ELECTRICAL / BOILER REPLACEMENTS. Clarkstown Central School District. June Arch Proj. #
ELECTRICAL ELECTRIC SERVICE EVALUATIONS / BOILER REPLACEMENTS Clarkstown Central School District June 2015 CSArch Arch Proj. # 151-1501.00 151 Table of Contents SECTION 1 Executive Summary... 1 SECTION
More informationMANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately
MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130.1) MANDATORY LIGHTING CONTROLS 1. 130.1 (a) Area Controls: Manual controls that control lighting in each area separately
More informationAppendix B. Facilities Assessment Report
Mile Lane Army Reserve Center Redevelopment Plan September 2008 Appendix B Facilities Assessment Report RKG Associates, Inc. Mile Lane Army Reserve Base Middletown, CT MEP System Evaluation For RKG Associates
More informationELECTRICAL SYSTEMS ASSESSMENT Hanover High School
ELECTRICAL SYSTEMS ASSESSMENT Hanover High School ELECTRICAL DISTRIBUTION SYSTEM:?? The existing electrical service consists of an underground primary service originating at a utility pole on Cedar Street,
More informationUNIVERSITY OF WISCONSIN-PLATTEVILLE REQUEST FOR ARCHITECTURE & ENGINEERING PRE-PLANNING & DESIGN SERVICES. for. Williams Fieldhouse - Phase I
UNIVERSITY OF WISCONSIN-PLATTEVILLE REQUEST FOR ARCHITECTURE & ENGINEERING PRE-PLANNING & DESIGN SERVICES for Williams Fieldhouse - Phase I 2007-2009 August 2007 DSF # 07E2H TABLE OF CONTENTS Scope of
More informationDissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013
WHITE PAPER Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard 90.1-2010 & 2013 JUNE 2016 DT213 (Rev.10.2.17) Executive Summary ASHRAE Standard 90.1 is developed with the Illuminating Engineering
More informationOregon Non-Residential Building Energy Code
Oregon Non-Residential Building Energy Code Interior Connected Lighting Power Requirements The requirements for interior lighting power are one of the most important sections of the Oregon Energy Code.
More informationF. GENERAL REQUIREMENTS Electrical Design Criteria 2009 Edition 11/23/2009 School District Palm Beach County Page-1 of 17
ELECTRICAL DESIGN CRITERIA TABLE OF CONTENTS I GENERAL...2 II CRITERIA...2 A. POWER DISTRIBUTION SYSTEMS...2 1. NORMAL POWER:... 2 2. EMERGENCY POWER... 3 B. LIGHTING...4 1. GENERAL... 4 2. AVERAGE MAINTAINED
More informationNORTH CENTRAL MICHIGAN COLLEGE PETOSKEY CAMPUS. Facilities Conditions Assessment Mechanical And Electrical Petoskey, Michigan
NORTH CENTRAL MICHIGAN COLLEGE PETOSKEY CAMPUS Facilities Conditions Assessment Mechanical And Electrical Petoskey, Michigan PBA Project No. 2014.0137.00 Prepared By: Wayne Kerbelis Terry Cleis September
More informationMANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)
MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130.1) MANDATORY LIGHTING CONTROLS 1. Area Controls: Manual controls that control lighting in each area separately 2. Multi-level
More informationCAMPUS PLANNING COMMITTEE STAFF REPORT SAMARITAN SPORTS MEDICINE INSTITUTE AT OSU 10/21/2013
Office of Capital Planning and Development; 130 Oak Creek Building; Corvallis, Oregon 97331-2001 CPC STAFF REPORT: SAMARITAN SPORTS MEDICINE INSTITUTE AT OSU CAMPUS PLANNING COMMITTEE STAFF REPORT SAMARITAN
More informationTechnical Report Two
Technical Report Two Yale Sculpture Building Advisors: Ted Dannerth Richard Mistrick Date: October 31, 2006 Electrical Systems Existing Conditions and Building Load Summary Report Executive Summary: This
More informationElement D Services Electrical ODG010107
Element D Services Electrical ODG010107 D5090 Other Electrical Systems Part 1. General This section includes design standards and requirements for other electrical systems. This is a design standard and
More informationF. GENERAL REQUIREMENTS Electrical Design Criteria 2006 Edition 4/3/06 School District Palm Beach County Page-1 of 15
ELECTRICAL DESIGN CRITERIA TABLE OF CONTENTS I GENERAL...2 II CRITERIA...2 A. POWER DISTRIBUTION SYSTEMS...2 1. NORMAL POWER:...2 2. EMERGENCY POWER...3 B. LIGHTING...4 1. GENERAL...4 2. AVERAGE MAINTAINED
More informationLIGHTING CONTROLS
260923 LIGHTING CONTROLS PART 1: GENERAL 1.01 SUMMARY COMMENTS A. CU has developed this lighting control guideline to direct design professionals toward standard solutions that meet the University s performance
More informationSpring Test 6 due 04/26/2013
Spring Test 6 due 04/26/2013 Multiple Choice Identify the letter of the choice that best completes the statement or answers the question. 1. The article that covers TV wiring installations in residences
More informationWASHINGTON DC METROPOLITAN AREA QUALIFICATIONS
WASHINGTON DC METROPOLITAN AREA QUALIFICATIONS CONTACT Arlington Virginia 1300 Wilson Boulevard Suite 450 Arlington VA 22209-2323 571.366.6800 571.366.6801 JOHN F. KENNEDY CENTER FOR THE PERFORMING ARTS
More informationPROJECT SPOTLIGHT TOUR: LANGAN LEADER JANUARY 2018
PROJECT SPOTLIGHT TOUR: LANGAN LEADER JANUARY 2018 Learn more about Langan's involvement in our featured projects. Armed Forces Retirement Home - Washington DC The Morgan School - Clinton CT Modera San
More informationExecutive Summary. CNBC Global Headquarters Christine Cajilig
Executive Summary This report contains an analysis and description of the existing electrical distribution of the including the distribution type, emergency power, uninterruptible power system, over current
More informationMANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)
MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130) MANDATORY LIGHTING CONTROLS 1. Area Controls: Manual controls that control lighting in each area separately 2. Multi-level
More informationConstruction Management at Risk Services. New North East Branch Library Project. August 3, 2018
Construction Management at Risk Services New North East Branch Library Project ADDENDUM 01 August 3, 2018 1. The attendance sheets (4 pages) from the Pre-Bid Conference are attached. 2. The proposals may
More informationDesign Presentation. Chief Operations Officer Willie Burroughs
Design Presentation Chief Operations Officer Willie Burroughs Agenda Introduction Community Feedback Project updates 2 Feedback Citizens Advisory Committee meetings Growth and Development meetings Community
More informationLighting Summary - Interior
Lighting Summary - Interior LTG-SUM Project Info Date: For Building Department Use Applicant Name: Applicant Address: Applicant Phone: Project Description F New building Addition Alteration Compliance
More informationMID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN
MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN September 30, 2015 PBA Project No. 2015.0140.00 PETER BASSO ASSOCIATES INC. CONSULTING ENGINEERS 5145 LIVERNOIS ROAD,
More informationLindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2
Lindsay Frederick Lighting + Electrical Ron Dodson Faculty Advisor Native American Cultural Center Arizona Technical Report 2 Native American Cultural Center Technical Report 2 p. 2 Executive Summary The
More informationMANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)
MANDATORY MEASURES INDOOR LIGHTING CONTROLS (Reference: Sub-Chapter 4, Section 130.1) MANDATORY LIGHTING CONTROLS 1. 130.1 (a) Area Controls: Manual controls that control lighting in each area separately
More informationSustainable Strategies for School Development in Urbanizing Areas
Sustainable Strategies for School Development in Urbanizing Areas A1 A2 A Corridor School as a part of a mixed- use development in Arlington VA PRECEDENT ANALYSIS Elementary Schools in different contexts
More informationCodes and Controls Commercial Building Energy Code Requirements for Light Control. Michael Jouaneh, CEM, LEED AP September 20, 2012
Commercial Building Energy Code Requirements for Light Control Michael Jouaneh, CEM, LEED AP September 20, 2012 Table of Contents What Code/Standard Does Your State Use?... 3 Mandatory Lighting Control
More informationFranklin Square Hospital Center
Franklin Square Hospital Center Baltimore, MD Thesis Proposal Cassandra Watson + Electrical Electrical Advisor Professor Dannerth Advisor Dr. Mistrick 16 December 2009 Table of Contents Executive Summary...
More informationGeneral RATIONALE services. dedicated. utility. that do not. sized. The. over the selection of the. equipment. Voltage.
Section 10 9 6 14 12 1 2 3 4 5 6 8 9 0 11 14 15 16 17 18 19 10 11 12 23 24 25 26 25 20 21 22 23 24 31 37 38 39 340 341 342 38 347 348 49 40 41 42 43 44 45 48 49 40 Section 10.9 General 10.9.0. This section
More informationELECTRICAL DESIGN BRIEF
4211 Yonge Street Suite 500 Toronto Ontario M2P 2A9 416 487 8151 f 416 487 9104 smithandandersen.com ELECTRICAL DESIGN BRIEF FOR 128 HAZLETON AVENUE RESIDENTIAL CONDOMINIUM BUILDING TORONTO, ONTARIO OUR
More informationElectrical Inspection Service & Distribution
0911 Distribution Panels & Switchgear Equipment, conduit, feeders, and grounding 480 Volt Switchboard: This switchboard contains the utility meter and two main, service, circuit breakers. One circuit breaker
More informationFacility Condition Assessment Summary Report. British Columbia Institute of Technology NE6 - Plumbing and Pipefit Building
Facility Condition Assessment Summary Report British Columbia Institute of Technology NE6 - Plumbing and Pipefit Building Submitted by: VFA Canada Corp. Burnaby Centre 4211 Kingsway Burnaby, BC V5H 1Z6
More informationTechnical Report 2: Electrical Systems Criteria and Existing Conditions
Technical Report 2: Electrical Systems Criteria and Existing Conditions Princeton Theological Seminary Library Princeton, NJ Stephanie Deckard Lighting Electrical Faculty Advisor Dr. Kevin Houser 10/12/2012
More informationMichigan State University DESIGN GUIDELINES. ELECTRICAL DESIGN Page 1 TABLE OF CONTENTS 1
Page 1 TABLE OF CONTENTS 1 ELECTRICAL 2 Summary Sustainability Electrical Distribution Lighting Detection and Alarm Communication Systems Lightning Protection Clock Systems Access Control Housekeeping
More informationHARRY RANSOM HUMANITIES RESEARCH CENTER
HARRY RANSOM HUMANITIES RESEARCH CENTER EXPANSION AND RENOVATION THE UNIVERSITY OF TEXAS AT AUSTIN SCHEMATIC LIGHTING DESIGN LIGHTING / ELECTRICAL OPTION DR. RICHARD MISTRICK, ADVISOR THE HARRY RANSOM
More informationDepth Work Part 1: Lighting Design
During the upcoming spring semester I will be investigating and redesigning some of the systems in Redifer Commons. This thesis study will be composed of three sections, which will all end up intertwining.
More informationShepherd University Wellness Center AE 481 Revised Thesis Proposal
A E 481 REVISED THESIS PROPOSAL Shepherd University Wellness Center AE 481 Revised Thesis Proposal Shepherdstown, West Virginia Lighting/ Electrical Option Dr. Houser and Professor Dannerth March 24, 2011
More informationApplied Lighting Controls
Better Buildings By Design 2010 Applied Lighting Controls Steven Mesh, LC, IESNA Senior Lighting Program Coordinator Pacific Energy Center (Pacific Gas & Electric) 851 Howard Street, San Francisco, CA
More informationCode Review TITLE PRESENTED BY POURIA NIKNAM
Code Review TITLE 24-2016 PRESENTED BY POURIA NIKNAM 2 Important Topics Partial-On as per Title 24 Definition and criteria for Daylight Responsive Control Controlled Receptacles Automatic Demand Response
More informationUniversity of California, San Diego Cal IT 2 Brian Smith. Schematic Design Presentation 06 December 2005
University of California, San Diego Cal IT 2 Brian Smith Schematic Design Presentation 06 December 2005 Building Overview Location: University of California, San Diego Size: 220,000 s.f. Architect: NBBJ
More informationState College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT
State College Area School District High School South Building Prepared by CenterPoint Engineering 08 February 2013 FACILITY ASSESSMENT SUMMARY PHYSICAL PLANT General HVAC This report is a snapshot of the
More informationELECTRICAL REQUIREMENTS FOR HEALTH CARE FACILITIES
ELECTRICAL REQUIREMENTS FOR HEALTH CARE FACILITIES Review Guide for: Hospitals Nursing Facilities Clinics Office of Statewide Health Planning and Development Facilities Development Division www.oshpd.ca.gov
More informationTechnical II Report Electrical Systems
Technical II Report Electrical Systems Kelly Chan Consultant: Prof T. Dannerth, P.E. Part A Drawings Drawings needed for single-line diagram EE1.01 title sheet (electrical drawings) EE2.09 penthouse/roof
More informationNewark, Delaware Architectural Engineering Senior Thesis Portfolio. Electrical Analysis
Electrical Analysis The AstroPower Headquarters building was constructed a few years ago to act as both a Headquarters and to be a display of what the product they manufacture can accomplish when put to
More informationINSPECTION REQUIREMENTS: ENERGY CODE LIGHTING & ELECTRICAL NON-RESIDENTIAL
Energy Code Lighting & Electrical Non-Residential Page 1 of 14 Revision Date: 2/12/2018 INSPECTION REQUIREMENTS: ENERGY CODE LIGHTING & ELECTRICAL NON-RESIDENTIAL INSPECTION CODE: N/A SCOPE: NON-RESIDENTIAL,
More informationPLATTEVILLE MIDDLE SCHOOL
Architectural The building has aluminum clad wood awning windows in combination with aluminum fixed glass units. They appear to be exterior glazed with insulated glazing. See photo 2. Platteville Middle
More informationTONY ESPOSITO LIGHTING/ELECTRICAL TECHNICAL REPORT II SEPTEMBER 15, 2011 HUNTER S POINT SOUTH INTERMEDIATE SCHOOL AND HIGH SCHOOL QUEENS, NY
LIGHTING/ELECTRICAL TECHNICAL REPORT II SEPTEMBER 15, 2011 HUNTER S POINT SOUTH INTERMEDIATE SCHOOL AND HIGH SCHOOL QUEENS, NY 1 1A. POWER DISTRIBUTION SYSTEMS a. EXECUTIVE SUMMARY b. SUMMARY DESCRIPTION
More informationNATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY
A new twist on the National Electrical Code - a practical application workshop. If you sign up in this class, prepare to work! Day 1: Fundamentals of OSHA requirements for performing electrical work -
More informationELECTRICAL Seminar. B A L A Consulting Engineers, Inc. Edward J. Lynch, PE Vice President, Electrical Department Manager.
B A L A Consulting Engineers, Inc. PECO Line 13.2kV Incoming Service No. 1 Utility/Generator Medium Voltage Switchgear PECO Line 13.2kV Incoming Service No. 2 Unit Substation ELECTRICAL Seminar HVAC Equip.
More informationHOLUM EDUCATION CENTER. Architectural. January 13, 2014 DeForest Area School District
HOLUM EDUCATION CENTER Architectural The existing building has approximately 41,823 square feet and sets on a lot about 4.14 acres in size. Parking lots are located along the east and west sides of the
More informationRenovate MCRC Facilities Great Lakes, IL
6. ENGINEERING SYSTEMS REQUIREMENTS D50 ELECTRICAL SYSTEM DESCRIPTION The electrical repair work includes the design and construction of the electrical distribution system for the B3200 Marine Corps Reserve
More informationEngineering Systems an Incremental Response to Terrorist Threat
ctbuh.org/papers Title: Authors: Subject: Keywords: Engineering Systems an Incremental Response to Terrorist Threat Norman D. Kurtz, Principal, WSP Flack + Kurtz Andrew Hlushko, Director, WSP Flack + Kurtz
More informationPage 1 of General
Page 1 of 8 16.1 General 1. This section covers items common to sections of CSI s Master Format - Division 16. 2. Dalhousie University is certified by IBEW for new construction and all electrical contractors
More informationThe AstroPower Headquarters Newark, Delaware
The AstroPower Headquarters Newark, Delaware Steven A. Neimeister The Pennsylvania State University Architectural Engineering Senior Thesis Presentation 13 April 2004 Presentation Outline Lighting Design
More informationINITIAL ELECTRICAL SAFETY ASSESSMENT - EXPANSION
INITIAL ELECTRICAL SAFETY ASSESSMENT - EXPANSION Yunusco (BD) Ltd(Formerly Shore To Shore Textiles Ltd.) Plot# 224-233, Adamjee EPZ, Shiddirgonj, Narayangonj Siddirgonj The Alliance for Bangladesh Worker
More informationMEETING NOTICE BOARD OF REGENTS OF THE UNIVERSITY OF WISCONSIN SYSTEM EXECUTIVE COMMITTEE
MEETING NOTICE BOARD OF REGENTS OF THE UNIVERSITY OF WISCONSIN SYSTEM EXECUTIVE COMMITTEE Friday, July 27, 2018 8:00 a.m. To be held by telephone conference 1511 Van Hise Hall 1220 Linden Drive Madison,
More informationAssessing Your Airfield Electrical Distribution System
Assessing Your Airfield Electrical Distribution System PRESENTED AT The 2017 Airports Conference March 30, 2017 Hershey, PA PRESENTED BY Samuel Mullen, III - Burns Engineering, Inc. 1 Presentation Objective
More informationPART 1. Executive Summary. The Frederick College of Cardiology
Executive Summary This report will summarize the electrical system of the Frederick College of Cardiology. First, an estimation of the possible building electrical loads will be performed. The actual loads
More informationSECTION : CAMPUS CENTRAL METERING SYSTEM DESIGN
Brown University Department of Facilities Management Design & Construction Standards 26 09 01 Campus Central Metering System Design SECTION 26 09 01: CAMPUS CENTRAL METERING SYSTEM DESIGN 1. GENERAL A.
More informationDates of Construction Construction Start 2/28/1999 Date of Completion 4/2000 Occupancy 5/2000
Executive Summary The Milton S. Hershey Medical Center Academic Support Building is located on The Pennsylvania State University's campus in Hershey, PA. The building is owned by The Pennsylvania State
More information13. ELECTRICAL - TECHNICAL
13. ELECTRICAL - TECHNICAL 13.1 GENERAL REQUIREMENTS 1. Base the electrical design on providing the following features at the most economical cost, considering both investment and operating expenditures:
More informationGoodwill Easter Seals - Miami Valley Headquarters
Goodwill Easter Seals - Miami Valley Headquarters Project Narrative Goodwill Easter Seals Miami Valley s Mission is to empower people with disabilities and other needs to achieve independence and enhance
More informationANSI/ASHRAE/IES
Vive Solutions Commercial Application Guide Code Compliance Lighting Controls ANSI/ASHRAE/IES 90. 206 Table of Contents ASHRAE ASHRAE 90.-206 90.-206 Introduction Solutions Overview... 2 Summary of Code
More informationANSI/ASHRAE/IES
Vive Solutions Commercial Application Guide Code Compliance Lighting Controls ANSI/ASHRAE/IES 90. 200 Table of Contents ASHRAE ASHRAE 90.-200 90.-200 Introduction Solutions Overview... 2 Summary of Code
More informationAir Flow Diagram. Orange County Sanitation District SP-194 Section 05 Conceptual Design
Orange County Sanitation District SP-194 Section 05 Conceptual Design Air Flow Diagram Two options are being analyzed for air distribution and temperature control within the building: Conditioned air shall
More informationLord Stirling Community School Electrical Systems Existing Conditions & Building Load Summary Technical Assingment#2 Due October 26, 2004
Electrical Systems Existing Conditions & Building Load Summary Technical Assingment#2 Due October 26, 2004 Table of Content: Page 1 ~ Single Line Diagram 1 2 ~ Electrical System Narrative 2-3 3 ~ Lamp
More informationFIRE ALARM: BY OTHERS, IF REQUIRED.
x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. CAPITAL LETTER DENOTES TYPE, LOWER CASE LETTER DENOTES SWITCH LEG. FLUORESCENT STRIP LIGHT FIXTURE,
More informationUBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5
Page 1 of 5 1.0 GENERAL 1.1 Related UBC Guidelines.1 Section 27 05 05 Communication Rooms Design Guidelines 2.13 1.2 Coordination Requirements.1 UBC Energy & Water Services.2 UBC Building Operations Electrical
More informationChang Liu Lighting + Electrical M.A.E./B.A.E. Integrated Degree. Technical Assignment 2 October 12, 2012 Faculty Consultants: Ron Dodson
M.A.E./B.A.E. Integrated Degree Technical Assignment 2 October 12, 2012 Faculty Consultants: Ron Dodson Renzo Museum of American Art Executive Summary This report provides an analysis of the electrical
More informationIDENTIFICATION FOR ELECTRICAL SYSTEMS July Electrical Systems
SECTION 26 05 54 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Nameplates. 2. Labels. 3. Wire markers. 4. Conduit markers. 5. Permanent Marking. 6. Underground
More informationC A L I F O R N I A E N E R G Y C O M M I S S I O N
C A L I F O R N I A E N E R G Y C O M M I S S I O N 38 Lighting Acceptance/Installation Cert. 2008 134 2013 130.4 Testing mandatory if controls/systems installed for: Multi-level controls Shut-off controls
More informationAlex Masterton, PE Electrical Engineer Reviewer AHCA Neal Boothe, PE Electrical Engineer/Principal
Alex Masterton, PE Electrical Engineer Reviewer AHCA Neal Boothe, PE Electrical Engineer/Principal FBC 419.3.15.6 All low-voltage system main or branch circuits entering or exiting the structure shall
More informationState College Area School District High School North Building EXISTING CONDITIONS ASSESSMENT
State College Area School District High School North Building Prepared by CenterPoint Engineering 08 February 2013 FACILITY ASSESSMENT SUMMARY PHYSICAL PLANT General HVAC This report is a snapshot of the
More informationChandler City Hall Chandler, Arizona
Chandler City Hall Chandler, Arizona AE481W: Architectural Engineering Senior Thesis Wednesday October 27 th, 2010 Stephanie Romanias Lighting/Electrical Faculty Consultant Dr. Kevin Houser/Professor Dannerth
More informationCode Compliance. Lightcloud. Guides for California Title 24 & ASHRAE
Guides for California Title 24 & ASHRAE Code Compliance Lightcloud Makes Compliance Easy What are California Title 24 & ASHRAE? Links to Energy Codes Interior Lighting Controls Exterior Lighting Controls
More informationTechnical Assignment 3
0 David H. Koch Institute for Integrative Cancer Research Senior Capstone Mechanical Option Technical Assignment 3 Mechanical Systems and Existing Conditions Report David H. Koch Institute for Integrative
More informationElectrical Systems Existing Conditions and Building Load Summary Report
The building was constructed a few years ago to act as both a Headquarters and to be a display of what the product they manufacture can accomplish when put to work. The building features both office and
More informationMOUNT PLEASANT MIDDLE SCHOOL HVAC. M-01 Heating Plant: M-02 Heating & Ventilating Systems: Livingston School District Mount Pleasant Middle School
MOUNT PLEASANT MIDDLE SCHOOL HVAC M-01 Heating Plant: The existing boilers have recently been upgraded. (3) steam boilers (8660 mbh each) manufactured by Weil- McLain have been installed. Newer hot water
More informationCosmetology Lab Redesign
Cosmetology Lab Redesign Shane A. Semple - 25-4/5/2005 Design Concept: The Cosmetology Lab is a space that will be used for teaching students the trades of cutting hair, applying make-up, and doing manicures.
More informationM001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings
1 T Consultant: NOTES, SYMBOLS & ABBREVIATIONS - MECHANICAL Number Description M001 Vestibule 117 LAN/IT Coffee 115 116 Mail Room 118 114 113 112 Scanning 119 Open Office 101 FIRST FLOOR PLAN - MECHANICAL
More informationVive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015
Vive Solutions Commercial Application Guide Code Compliance Lighting Controls Table Table of of Contents Contents Introduction Solutions Overview... 2 Summary of Code Requirements... 4 Daylight Zone Requirements...
More information10606 Bloomfield Ave Santa Fe Springs, CA USA
IAS Accreditation Number FEB-103 Company Name eti Conformity Services Address 10606 Bloomfield Ave Santa Fe Springs, CA 90670 USA Contact Name Sam Daye Telephone (562) 236-9555 Effective Date of Scope
More informationEncumbered Balance (E-D) Branham HVAC Implementation Complete 100% 03/04/19 07/19/19 $765, $635, $635, $130, $0.
Branham High School Budget Remaining 1 906030 Branham HVAC Implementation Complete 100% 03/04/19 07/19/19 $765,473.00 $635,342.00 $635,342.00 $130,131.00 $0.00 2 970205 Branham Interim Housing - 12 Portable
More informationCompliance w/ the 2012 Life Safety Code
Compliance w/ the 2012 Life Safety Code Implications of the 2012 NFPA Code Set for Existing & New ASCs William E. Lindeman, AIA http://www.weldesigns.com Financial Interest Disclosure The presenter provides
More informationCITY OF LOS ANGELES LARUCP ELECTRICAL PLAN CHECK LIST
CITY OF LOS ANGELES LARUCP ELECTRICAL PLAN CHECK LIST Plan Check No. Plan Check Expiration Date Job Address: Square Footage Use Zone Fire Zone Occ. Group Type of Construction No. of Stories Applicant Phone
More informationCHAPTER 8 ELECTRICAL
CHAPTER 8 ELECTRICAL 8.1 GENERAL... 3 8.2 REQUEST FOR PROPOSAL DEVELOPMENT... 3 8.3 DESIGN DEVELOPMENT... 3 8.3.1 CONCEPT (30%) DESIGN SUBMITTAL REQUIREMENTS... 3 8.3.1.1 Concept Design Analysis... 3 8.3.1.1.1
More informationLANGAN LANDSCAPE ARCHITECTURE + PLANNING FOR COLLEGES & UNIVERSITIES
LANGAN LANDSCAPE ARCHITECTURE + PLANNING FOR COLLEGES & UNIVERSITIES CONTACT Philadelphia Pennsylvania 1818 Market Street Suite 3300 Philadelphia PA 19103 215.845.8900 215.845.8901 ST. JOSEPH'S UNIVERSITY
More information