SecuriFire 500/1000/2000/3000

Size: px
Start display at page:

Download "SecuriFire 500/1000/2000/3000"

Transcription

1 SecuriFire 500/1000/2000/3000 Product Catalogue 2016

2 Content 1. Cabinets variants SecuriFire 500 fire alarm control panel SecuriFire 1000 fire alarm control panel SecuriFire 2000 fire alarm control panel SecuriFire 3000 fire alarm control panel Demo and Test Equipment Indication and Operating Panels Built-in Indication and Operation Panels External Indication and Operation Panels Equipment Mounting Frames SecuriFire 2000 Units Boards SecuriFire SecuriLine extended Modules Accessoires for Loop Modules Addressable Detectors SecuriStar SecuriStar SecuriLine extended Addressable Ventilation Duct Detectors SecuriLine extended SecuriStar SecuriLine Conventional Detectors SecuriStar Flame Detectors Conventional Accessories for Flame Detectors Conventional Ex/Atex approved Detectors Accessories for Ex/Atex approved Detectors Modernisation Detectors and Modules for SecuriFire Bases and Accessories for SecuriStar Detectors Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

3 12. Room Indication Lamps Manual Call Points Addressable Manual call points SecuriLine extended Conventional Manual Call Points Accessories for MCP Special Detectors Alarm Indication Modules Acoustical Alarm Medium Optical Alarm Medium Combined Siren /Beacon Radio Detectors Overvoltage Protection Devices Batteries Installation, Test and Commissioning Tools Detector Test Equipment Loop Test Equipment Product Type Index Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000 3

4 Introduction SecuriFire is a superbly adaptable life safety system, lending itself to small, medium and large building applications. Virtually no limits SecuriFire is a modular system uniquely designed to easily meet the needs of standalone installations or multi-node networked systems. A single node system supports up to 16 loop controllers with up to 250 devices per loop, depending on the loop protocol used (SecuriLine extended or standard). Up to 16 alarm panels can be networked in one sub-system. Up to 64 sub-systems can be networked to a virtually unlimited installation. Fully Redundant - Totally Failsafe 8 Zones Extinguishing Consistency is the hallmark of any great organization or process. When it comes to fire detection systems, consistency is not a desired goal; it is a must. SecuriFire 3000 is the only 100% failsafe system on the market. It provides redundant processing exceeding the stringent EN54 requirements. Its full hardware redundancy and wiring flexibility are not found in any other system. The full hardware redundancy allows for eight (8) extinguishing zones per panel. Small but power-packed: tailor-made fire detection of the highest standard SecuriFire 1000/2000 provides a cost-optimised state-of-the-art system that is always up to the task, no matter how tough the conditions. The unique principle of software redundancy ensures that the fire alarm control panel is capable of raising the alarm at all times and under all conditions. SecuriFire 1000/2000 constantly self-tests its functionality, signalling any faults immediately. SecuriFire 1000/2000 adapts perfectly to every building and every safety requirement. SecuriFire 500 adapts perfectly to every building and every safety requirement. SecuriFire 500 constantly self-tests its functionality, signalling any faults immediately. The systems are ideally suited for small-sized premises such as hotels, restaurants, guest houses, shopping malls and leisure centres, retirement homes and all kinds of other facilities. The systems are compatible with existing and future generations of detectors. The solutions implemented as a result are utterly convincing, both economically and from a safety viewpoint. Superb User Interface The high resolution LCD colour graphics display talks your language and is designed to reduce operator interactions in critical situations and maximize design flexibility for custom systems. In addition to front panel control and annunciation, Securiton s Universal Management System (UMS) provides desktop control and messaging in the familiar Windows environment. It gives the user access to all security installations - including fire detection, intrusion alarm, access control and CCTV in one simple and intuitive interface. SecuriFire Studio A powerful System Definition Utility program helps define system operations in a fraction of the time required by previous methods. Virtually all SecuriFire operating features are software controlled. This gives SecuriFire unparalleled flexibility and ensures operational changes, expansions and upgrades will be possible with ease, even years after the initial setup. Tested & Certified All SecuriFire system modules are tested against EN standards and certified by VdS. 4 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

5 How to read the catalogue Example of a typical entry for an item Type & Article Number Please quote this number when making an enquiry or ordering. Module for monitored outputs B3-OM8 For connecting peripheral devices (flashing lights, sirens etc.); with eight 1.5 A controller outputs monitored for short circuits and wire breaks Operating voltage 20 to 30 V DC Current consumption 60 ma Ambient temperature -5 C to +45 C Dimensions (H x W x D) 120 x 60 x 50 mm Illustration Description and technical data Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000 5

6 SecuriFire 500 System Overview 6 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

7 SecuriFire 1000 System Overview Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000 7

8 SecuriFire 2000 System Overview 8 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

9 SecuriFire 3000 System Overview Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000 9

10 Side-by-side comparison of SecuriFire 500, 1000, 2000 and 3000 SecuriFire 500 SecuriFire 1000 SecuriFire 2000 SecuriFire 3000 Loops 1 1 Up to 4 Up to 16 Optional: Input / Output - X X X Optional: 485/IP Network Optional: collective detectors - - X X - - X X Power supply 2,4 A 4 A 4 A 7 A Extinguishing certified EN X X MMI-BUS - X X X EPI-BUS X X X X SecuriLan - - X X Monitored Input X Monitored Output X Relay X 10 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

11 1. Cabinets variants 1.1. SecuriFire 500 fire alarm control panel SCP 500 Cabinet B7-SCP520 built-in SecuriFire 500 Basic Version, with SecuriFire 500 basic version including: - Polycarbonate cabinet (grey) - B7-CPB11 Central Processor Unit - Battery compartment (max. batt. size 2 x 12 V/ 7 Ah) Mains voltage / Frequency: 110/230 VAC +15%/-20% Hz Power Consumption: max. 75 W Output voltage: 26,3 VDC (+50 C) to 28,3 VDC (0 C) Output current: 2,5 A Max. switching voltage: 240 VAC / 125 VDC Max. switching current: 3 A Max. switching capacity: 300 W / 2,500 VA Batteries (largest): 2 pieces. 12 V / 7 Ah in series Protection class (DIN 40050): IP 30 Ambient temperature: -5 to +50 C Rel. air humidity: 5 to 95%, without condensation Cabinet: Polycarbonate Dimensions (HxWxD): 300 x 340 x 80 mm Weight of basic version: 2,3 kg (without batteries) Case colour: grey RAL 7016 VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

12 1.2. SecuriFire 1000 fire alarm control panel SCP 1000 Cabinet (key lock) SCP 1020 B6-SCP1020 Basic version, B6-SCP1020A with built-in operating panel SecuriFire 1000 basic version including: - Sheet steel cabinet (grey) - DOM-lock - B6-BCB12 Central processor unit - B6-PSU Power supply unit - Power clips and battery cable - Battery compartment (max. batt. size 2 x 12 V/17 Ah) SecuriFire 1000A basic version including: Same as SecuriFire 2000 except: - B6-BCB12A Central processor unit - B9-PSU Power supply unit (110/230 VAC) Mains voltage / Frequency: 230 VAC +15%/-20% Hz Power Consumption: max. 160 W Output voltage: 26,3 VDC (+50 C) to 28,3 VDC (0 C) Output current: 4 A Max. switching voltage: 240 VAC / 125 VDC Max. switching current: 3 A Max. switching capacity: 300 W / 2,500 VA Batteries (largest): 2 pieces. 12 V / 17 Ah in series Protection class (DIN 40050): IP 30 Ambient temperature: -5 to +50 C Rel. air humidity: 5 to 95%, without condensation Cabinet: Sheet steel Dimensions(HxWxD): 400 x 445 x 150 mm Weight of basic version: 8 kg (without batteries) Case colour: grey RAL 7035 VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

13 1.3. SecuriFire 2000 fire alarm control panel SCP 2000 Cabinet (key lock) SCP 2010 SCP 2020 B6-SCP2010 Basic version B6-SCP2010A B6-SCP2020 with built-in operating panel B6-SCP2020A B6-SCP2030 with built-in operating panel and printer B6-SCP2030A B6-SCP2040 with built-in operating panel, B6-SCP2040A printer and cut out for EPI devices or Ext. Zone panel B6-SCP2050 with built-in operating panel, B6-SCP2050A and cut out for EPI device SecuriFire 2000 basic version including: - Sheet steel cabinet (grey) - DOM-lock - B6-BCB13 Central processor unit - B6-PSU Power supply unit - Power clips and battery cable - Battery compartment (max. batt. size 2 x 12 V/17 Ah) SecuriFire 2000A basic version including: Same as SecuriFire 2000 except: - B6-BCB13A Central processor unit - B9-PSU Power supply unit (110/230 VAC) SCP 2030 SCP 2040 SCP 2050 Mains voltage / Frequency: 230 VAC +15%/-20%47-63 Hz Power Consumption: max. 160 W Output voltage: 26,3 VDC (+50 C) to 28,3 VDC (0 C) Output current: 4 A Max. switching voltage: 240 VAC / 125 VDC Max. switching current: 3 A Max. switching capacity: 300 W / 2,500 VA Batteries (largest): 2 pieces. 12 V / 17 Ah in series Protection class (DIN 40050): IP 30 Ambient temperature: -5 to +50 C Rel. air humidity: 5 to 95%, without condensation Cabinet: Sheet steel Dimensions(HxWxD): 400 x 445 x 150 mm Weight of basic version: 8 Kg(without batteries) Case colour: grey RAL 7035 VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

14 1.4. SecuriFire 3000 fire alarm control panel SCP 3000 Cabinet (key lock) SCP 3010 SCP 3020 B5-SCP3010 Basic version FG B B5-SCP3010A B5-SCP3020 with built-in operating panel FG B B5-SCP3020A B5-SCP3030 with built-in operating panel and printer FG B B5-SCP3030A B5-SCP3040 with built in panel, printer and cut out FG B B5-SCP3040A for EPI-device B5-SCP3050 with built in panel, printer and cut out B5-SCP3050A for MMI-device SecuriFire 3000 basic version including: - Sheet steel cabinet (grey) - DOM-lock - B5-MCB15 Central Processor Unit - B5-PSU power supply unit - Module rack with BUS backplane - Battery compartment (max. batt. size 2 x 12 V/40 Ah) SecuriFire 3000A basic version including: Same as SecuriFire 3000 except: - B5-MCB15A Central Processor Unit - B8-PSU power supply unit (110/230 VAC) - Module rack with B8-BUS backplane SCP 3030 SCP 3040 SCP 3050 Mains voltage / Frequency: 230 VAC +15%/-20% Hz Power Consumption: max. 280 W Output voltage: 26,3 VDC (min. At +50 C) Output current: 7,5 A Max. switching voltage: 230 VAC / 125 VDC Max. switching current: 3 A, both pins on terminals Max. switching capacity: 300 W /2,500 VA Batteries (largest): 2 x 12 V / Ah Protection class (DIN 40050): IP 30 Ambient temperature: -5 to +50 C Rel. air humidity: 5 to 95%, without condensation Cabinet: Sheet steel Dimensions (HxWxD): 670 x 470 x 230 mm Weight of basic version: 23.5 kg (without batteries) Case colour: grey RAL 7035 VdS-Approval: G Accessories: Description Type Art. No. B5 Advanced Upgrade Kit, SecuriFire B5-UGKA-SF Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

15 SecuriFire Control Panel Accessories and Spare Parts Panel Accessories: Description Type Art. Nr. Battery Extension Box (key lock), max 2 x 12V/45 Ah,size like SF3000 B5-ADB Battery Extension Box, max 2 x 12V/17 Ah, size like SF2000 B6-ADB Battery current measure cable B3 KAB PSU5 FG81720 Cable for MMI-BUS with connector (between BAF/PSU and MMI-BUS part.) B5-STS-MMI-SUB Cable for MMI-BUS with connector (between two MMI-BUS part.) B5-STS-MMI Mains connection termionals for PSU B5-STS-KL Blind plate for covering free slots B5 BFP FG Color cassette for printer PD FRB HG Connection unit for SecuriFire Network module B5-AE Cat7-RJ Connector for SecuriFire Network module B6-AS Cat7-RJ Distance frame for additional 20mm space DFC Endless paper for printer PD PPR PPF Mounting rail for connection unit B5-HS 35/ Patch cable for network module Cat5-Kabel 0,5 m Patch cable for network module Cat5-Kabel 3 m Printer cover for SecuriFire Printer B5-PDR-CO Covering Strip (2 pcs.) COS SD-CARD for B5/B6 SD-CARD for B5/B6 FG key to DOM-cylinder DOM-key Spare Parts: Description Type Art. Nr. Basic control board for SCP520 B7-CPB Basic control board for SCP1000 B6-BCB Basic control board for SCP1000A B6-BCB12A Basic control board for SCP2000 B6-BCB Basic control board for SCP2000A B6-BCB13A Main control board for SCP3000 B5-MCB15 EG A Main control board for SCP3000 A B5-MCB15A Main Indication & Control Panel, non-redundant, for SCP1000 /2000 B6-MIC11 FG Main Indication & Control Panel, non-redundant, for SCP1000 /2000 B9-MIC Main Indication & Control Panel, redundant, for SCP3000 B5-MIC11 FG Main Indication & Control Panel, redundant, for B8-SCP3000 B8-MIC B5-PSU power supply unit B5-PSU EG B8-PSU power supply unit B8-PSU B6-PSU Power Supply Unit B6-PSU EG B9-PSU Power Supply Unit B9-PSU B5-BUS System bus circuit board B5-BUS EG B8-BUS System bus circuit board B8-BUS Bus circuit board for Relay bus B3-BSR5 EG Board mounting support B3-BGT FG67020 Fuse SI 8A for battery cable ZUB SICH8 IS G-Fuse 2.5A FF 5x20 ZUB SICH IS Protocol printer device B5-PDR-DW FG Battery Cable B6 BATKAB EI29940 B4 Service bridge B4 SERVBR FG78802 Plugs for B4 /B6-EIO inputs, 2 pcs ST-SET-EIO FG74109 Connector B4-OM ST-OM YK Connector B4-LOOP / DAI ST-LOOP/DAI YK Connector B4-REL6 ST-REL6 YK Connector BAF/FBD ST-BAF-FBD YK pin solder plug for B3-LPI/USI4/HFI ST-LPI/USI4/HFI FG74097 Connector USI4 ST-USI4 FG74098 Internal printer I/F B5-PIF EG External printer I/F B5-PIE-A EG Battery cable set B5 BATKAB1 FG29910 Battery cable set long B5 BATKAB2 FG29911 B3 Service pin B3 SERVST FG78801 Connector DAI2 / DXI2 ST-B3 16 YY Connector DCI6 ST-DCI6 FG74099 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

16 Connector MTI8 / IM8, angulate (2 units, screwable on the side) ST-MTI8 FG74087 Connector OM8 ST-OM8 FG74095 Connector BAF/OM ST-BAF-OM FG74088 Connector BAF-MMI/L ST-BAF-MMI-L FG74086 Connector PSU5 ST-PSU5 FG74090 Key for SCP520 DKM SCHL FG Software Dongles and Licenses: Description Type Art. Nr. License SecuriFire including USB Dongle D&L Studio VE License SecuriFire Studio 12 Months (extension) LIC Studio VE SecuriFire Virtual MIC simulation on PC (unlimited license) D&L MIC Sim VE Remote access Upgrade (unlimited license) LIC RA VE Additional Language (check library for availability) LIC MIC Lang VE Also available upon request: Ethernet cable 3m or 5m for linking the Service PC-via MCB Demo and Test Equipment SecuriFire 500 Democase SF 500 DCU The SFD500 is a demonstration case for SecuriFire Containing B7-SCP520, 1 MCD 573X, 1 CCD 573, RAL 720X and MCP 535X. For sales demonstration - Compact Dimension - Incl. power cable (swiss standard) - Incl. LAN cable to connect the SecuriFire Studio VE Power Consumption: Weight: Dimensions (HxWxD): max. 75 W 9.5 kg 395 x 422 x 242 mm 16 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

17 2. Indication and Operating Panels 2.1. Built-in Indication and Operation Panels B4 indicator panel for 1 exting. area without housing incl. cable Built in Fire brigade panel CH B4-EIP (without case, for mounting in a SCP 2040/2050) Single-zone extinguisher display Internal LED control panel for one extinguishing area, Characteristics: - Display foil with 12 LEDs for extinguishing area - Collective display with 9 LEDs - Key switch for maintenance, extinguishing area in revision - Labelling is by means of insertion strips (for Switzerland) B5-EPI-FPC-E (without case, for mounting in a SCPxxxx) Fire brigade panel providing an easy man-machineinterface for the fire brigade. Features a language independent application by means of pictograms. Connects via its EPI bus (cable included). FG81624A Operating voltage: Quiescent current: Ambient temperature: Dimensions (HxWxD): 22 to 30 V 1 ma -5 to +50 C 85 x 70 x 20 mm Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

18 B3 Indicator Panel for 32 DZ w/o housing B3-MMI-EAT32 BFE ( w/o housing / for panel integration) LED indicator panel for indication of alarm, fault and disablement states for 32 detector zones. The labelling uses push-in strips (not supplied) with the device also available without a case for fitting in switching cabinets. FG81622A9F B3 Indicator Panel for 4 exting. zones w/o housing B3-MMI-IPES BFE ( w/o housing / for panel integration) LED indicator panel for indication of alarm, fault and disablement states for 4 extinguish zones. The labelling uses push-in strips (not supplied) with the device also available without a case for fitting in switching cabinets. FG81620A9F B3 External Indicator Panel for 64 DZ w/o housing B3-MMI-EAT64 BFE (without housing) LED indicator panel for indication of alarm, fault and disablement states for 64 detector zones. The labelling uses push-in strips (not supplied) FG F Operating voltage: 10 to 30 V Quiescent current: 2 ma per lit LED Data transmission: MMI-BUS Electrical: galvanically isolated RS 485 Protocol: serial, DIN Distance to sub control unit: max m Protection class: IP 30 Ambient temperature: 0 to +50 C Dimensions(HxWxD): 228 x 445 x 48 mm B3 External Indicator Panel for 8 exting. zones w/o housing B3-MMI-IPEL BFE (without housing) External LED indicator panel for eight extinguishing zones (twelve LEDs per extinguishing zone and group indicator with nine LEDs), including case, key switch and controller module. The labelling uses push-in strips (not supplied) FG F Operating voltage: 10 to 30 V Quiescent current: 2 ma per lit LED Data transmission: MMI-BUS Electrical: galvanically isolated RS 485 Protocol: serial, DIN Distance to sub control unit: max m Protection class: IP 30 Ambient temperature: 0 to +50 C Dimensions (enclosure) (HxWxD): 228 x 445 x 48 mm 18 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

19 2.2. External Indication and Operation Panels The SecuriFire standard indication and control maps provide well-organized, convenient, standards-compliant display and operation of a SecuriFire system and can be built into a FCP or separately mounted in their own housings. External devices and indication and control maps can be connected to the EPI-BUS on each MIC. A maximum of 3 participants can be connected to this data bus at a distance of up to 1 m from the main indication and control map MIC. Main Indication & Control Panel B5-MIC711 (for RS485, redundant) External main indication and control panel for SecuriFire User-friendly full operation with "SecuriWheel" and system symbols. Characteristics: - For SecuriFire LAN TFT-Colour Display - Customized menus (optional) - Operation with scroll wheel or functional keys - 4 different languages changeable online - Up to 1200-m distance between MIC711 and central - Redundant by double ring crosslinking - Crosslinking with Ethernet protocol possibly (RX/TX) - EPI-BUS- Interface - Interface for external printer B5-MIC-PPE Operating voltage: Quiescent current: Ambient temperature: Dimensions (HxWxD): Display: 22 to 30 V 213 ma -5 to +50 C 276 x 170 x 52 mm 5.7 TFT colour Main Indication & Control Panel B6-MIC711 (for RS485, non redundant) External non redundant main indication and control panel for SecuriFire User-friendly full operation with "SecuriWheel" and system symbols. Characteristics: - For SecuriFire LAN TFT-Colour Display - Customized menus (optional) - Operation with scroll wheel or functional keys - 4 different languages changeable online - Up to 1200-m distance between MIC711 and central - Crosslinking with Ethernet protocol possibly (RX/TX) - EPI-BUS- Interface - Interface for external printer B5-MIC-PPE Operating voltage: Quiescent current: Ambient temperature: Dimensions (HxWxD): Display: 22 to 30 V 213 ma -5 to +50 C 276 x 170 x 52 mm 5.7 TFT colour Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

20 Floor indication panel B5-MMI-FIP The SecuriFire floor indication panel provide well organized and convenient announcement of the conditions of the SecuriFire - system. It contains a monochrome LCD display with 6 lines for the indication of all investment conditions in the clear text. No inscription on housing front (only announcement elements). Characteristics: - Connection to MMI-BUS - Up to 1200m distance between FIP and central possible - EPI-BUS-Interface Operating voltage: Quiescent current: Ambient temperature: Dimensions(HxWxD): Display: 22 to 30 V 213 ma -5 to +50 C 276 x 170 x 52 mm LCD display with 6 lines Empty housing with blind cover EHB (EPI panel size) The EHB 701 Empty Housing with Blind cover is for the SecuriFire fire alarm control panel or the SecuriSafe intrusion control panel. It can be used as a distributor box, installation box, or for similar applications Protection class: IP 42 Dimensions(HxWxD): 137,5 x 170 x 45 mm 20 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

21 B3-UIO Universal In/Output Module B3-MMI-UIO For controlling the floor plan and parallel display panels or as a remotely located input/output module for querying potential-free contacts (sprinkler systems), or also for controlling non-monitored horns, lamps, relays etc. EG Operating voltage: 10 to 30 V Current consumption: 14 ma Data transmission: MMI-BUS Electrical: galvanically isolated RS 485 Protocol: serial, DIN Distance to subcontrol unit: max m Connection: Floor plan panels, parallel indicator panels, flashing lights, sirens, horns, sprinkler systems, etc. LED Outputs: 64 LED outputs 2 ma LEDs per panel: max. 256 Open Collector Outputs: 8 up to max.100 ma Output voltage max. +30 V Matrix Configuration: 8 inputs with 8 outputs in an 8 x 8 matrix Supply Voltage: +5 VDC Current Draw: max. 3.3 ma Ambient temperature: -5 to +50 C Dimensions(HxWxD): 160 x 105 x 20 mm VdS-Approval: G Accessories: Description Type Art. Nr. Plastic Box UIO-GEH FG69041 Support plate UIO STP FG05203 Ribbon cable 34 pole with plug (1m) UIO KAB 34 FG81725 Ribbon cable 40 pole with plug (1m) UIO KAB 40 FG81726 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

22 B3 External Indicator Panel for 64 DZ B3-MMI-EAT64-S LED indicator panel for indication of alarm, fault and disablement states for 64 detector zones. The labelling uses push-in strips (not supplied). The device is also available without a case for fitting in switching cabinets Operating voltage: 10 to 30 V Quiescent current: 2 ma per lit LED Data transmission: MMI-BUS Electrical: galvanically isolated RS 485 Protocol: serial, DIN Distance to subcontrol unit: max m Protection class: IP 30 Ambient temperature: 0 to +50 C Dimensions (HxWxD): 228 x 445 x 48 mm Case colour: grey RAL 7016 B3 External Indicator Panel for 8 exting. zones B3-MMI-IPEL-S External LED indicator panel for eight extinguishing zones (twelve LEDs per extinguishing zone and group indicator with nine LEDs), including case, key switch and controller module. The labelling uses push-in strips (not supplied). The device is also available without a case for fitting in switching cabinets Operating voltage: 10 to 30 V Quiescent current: 2 ma per lit LED Data transmission: MMI-BUS Electrical: galvanically isolated RS 485 Protocol: serial, DIN Distance to subcontrol unit: max m Protection class: IP 30 Ambient temperature: 0 to +50 C Dimensions (enclosure) (HxWxD): 228 x 445 x 48 mm Case colour: grey RAL Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

23 Intervention panel SV (for Sweden ) B5-MMI-IPS-S (cased version for external mounting) Intervention panel. Displays the relevant operating states to ensure simple operation by the fire brigade. Display message and labels are in Swedish language Operating voltage: Quiescent current: Ambient temperature: Dimensions (HxWxD): 15 to 30 V 14 ma -5 to +50 C 180 x 55 x 280 mm (HxWxD) Fire brigade panel SV Firebrigade panel CZ (for Sweden) B5-MMI-FPS-S (cased version for external mounting) Fire brigade panel. Displays the relevant operating states to ensure simple operation by the fire brigade. Operating voltage: 15 to 30 V Quiescent current: 14 ma Ambient temperature: -5 to +50 C Dimensions (HxWxD): 276 x 170 x 52 (for Czech Republic) B5-MMI-FPCZ (cased version for external mounting) Intervention panel display and indicator panel. Displays the relevant operating states to ensure simple operation by the fire brigade Operating voltage: Quiescent current: Ambient temperature: Dimensions (HxWxD): 15 to 30 V 14 ma -5 to +50 C 185 x 255 x 65 mm Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

24 Fire brigade panel CZ Fire Brigade Panel SV Fire brigade panel CH (for Czech Republic) B5-EPI-FPCZ (cased version for external mounting) DIN compliant fire brigade panel display and indicator panel. Displays the relevant operating states to ensure simple operation by the fire brigade. Provides an interface for extending the installation by a DIN14661 compliant fire brigade control panel. Display message and labels are in Czech language. Operating voltage: 22 to 30 V Quiescent current: 21 ma Data transmission: EPI-BUS Electrical: galvanically isolated RS 485 Protocol: serial, DIN Distance to subcontrol unit: max m Protection class: IP 30 Ambient temperature: 0 to +50 C Dimensions (HxWxD): 185 x 255 x 65 mm Case colour: grey RAL 7032 (for Sweden) B5-EPI-FPS-S (cased version for external mounting) SS3654 compliant fire brigade panel display and indicator panel. Displays the relevant operating states to ensure simple operation by the fire brigade. Display message and labels are in Swedish language Operating voltage: 15 to 30 V Quiescent current: 14 ma Ambient temperature: -5 to +50 C Dimensions(HxWxD): 276 x 170 x 52 (for Switzerland) B5-EPI-FPC-GS (cased version for external mounting) Fire brigade panel providing an easy man-machineinterface for the fire brigade. Features a language independent application by means of pictograms. Fits neat & nice beside a MIC711 and connects via its EPI bus (cable included). Operating voltage: 22 to 30 V Quiescent current: 0 ma Ambient temperature: -5 to +50 C Dimensions (HxWxD): 138 x 170 x Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

25 Partial Indication and Control Map B5-EPI-PCM-GS (cased version for external mounting) For switching and indicating functions in a SecuriFire system. Functions on buttons and LEDs can be configured via software LEDs (8 red and 8 yellow, pair wise) - 8 push buttons Operating voltage: Quiescent current: Ambient temperature: 22 to 30 V 0 ma -5 to +50 C Partial Indication Map ( 2x16 LED red/yellow) B5-EPI-PIM-GS (cased version for external mounting) For status indication of detectors, zones or any other system parts. LEDs can be configured via software LEDs (16 red and 16 yellow, pair wise) Operating voltage: Quiescent current: Ambient temperature: 22 to 30 V 0 ma -5 to +50 C Indication & Contr. Panel (8 Buttons, 3x16 LED, red/ylw) in a SCP 500 housing B7-PLB-PCM SCP Cabinet with built in Partial indication and Control map (3 x16 LED red/yellow, 8 Buttons) Characteristics: - EPI-BUS- Interface Operating voltage: Quiescent current: Ambient temperature: Dimensions(HxWxD): 22 to 30V 213 ma -5 to +50 C 300 x 340 x 80 mm Printer for MIC711 B5-MIC-PPE Protocol printer for hard copy documentation of logged events. Comes in a MIC size housing and with the cable to connect it to the MIC Operating voltage: Quiescent current: Power Consumption (print): Ambient temperature: Dimensions (with case) (HxWxD): Spare parts 10 to 30 V 0 ma 35 ma 0 to +50 C 170 x 138 x 62 mm Description Type Art. Nr. Colour cartridge for printer PD FRB HG Paper roll for protocol printer PD PPR PPF Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

26 Equipment 19" Rack Version, incl. B5-PSU, B5-BUS, B5-MCB15, battery compartment B5-STS-BGT-SF SecuriFire 3000 Rack for mounting in a 19 standing cabinet. Inclusive: - B5-PSU - B5-BUS - B5-MCB15 - Battery compartment B5-STS-AF 19" Rack Version, incl. B8-PSU, B8-BUS, B8-MCB15, battery compartment B8-STS-BGT-SF Front plate for MIC711 or 2 EPI devices SecuriFire 3000 B8 Rack for mounting in a 19 standing cabinet. Inclusive: - B8-PSU - B8-BUS - B8-MCB15 - Battery compartment B5-STS-AF B5-STS-MIC Front plate for MIC711 or 2 EPI devices, for mounting in a 19" standing cabinet. (5 RU) Front plate for MIC711 and EPI device B5-STS-MIC2 Mounting frame for 19 standard closet with cut out for one MIC711 and EPI device or 3 EPI devices. (5 RU) Battery compartment for standing cabinet B5-STS-AF Battery compartment to store batteries in a 19 standing cabinet Printer for 19" B5-STS-PR-2 Front plate for a protocol printer, for mounting in a 19" standing cabinet Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

27 Blind plate small for 19" (1 RU) B5-STS-BFP2-2 Blind front plate small, for mounting in a 19" standing cabinet Blind plate for 19" (5 RU) B5-STS-BFP-2 Blind front plate, for mounting in a 19" standing cabinet External Indicator Panel for 64 DZ 19 (5 RU) B5-STS-MMI-EAT64-2 LED indicator panel 19 for indication of alarm, fault and disablement states for 64 detector zones. The labelling uses push-in strips (not supplied).the device is also available without a case for fitting in switching cabinets Operating voltage: 10 to 30 V Quiescent current: 2 ma per lit LED Data transmission: MMI-BUS Electrical: galvanically isolated RS 485 Protocol: serial, DIN Distance to subcontrol unit: max m Protection class: IP 30 Ambient temperature: 0 to +50 C Dimensions (HxWxD): 228 x 445 x 48 mm Case colour: grey RAL 7016 External Indicator Panel for 8 exting. zones 19 (5 RU) B5-STS-IPEL-2 External LED indicator panel 19 for eight extinguishing zones (twelve LEDs per extinguishing zone and group indicator with nine LEDs), including case, key switch and controller module. The labelling uses push-in strips (not supplied) Operating voltage: 10 to 30 V Quiescent current: 2 ma per lit LED Data transmission: MMI-BUS Electrical: galvanically isolated RS 485 Protocol: serial, DIN Distance to subcontrol unit: max m Protection class: IP 30 Ambient temperature: 0 to +50 C Dimensions (enclosure) (HxWxD): 228 x 445 x 48 mm Case colour: grey RAL 7016 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

28 2.4. Mounting Frames Flush mounting kit for MIC711, EPI device and plan box FME 70-1 Consists from flush mounting case with frame and attachment screw, to SecuriFire indication and control panels. Incl. plan box PLB 70-1 For 1 MIC and 1 small operating device and plan box Dimensions (H x D x W): Spare Parts: 459x542x90 mm Flush mounting kit for MIC711 and plan box Description Type Art. Nr. Frame for flush mounting equip. FFM Flush Mounting Case FMC Plan box PLB FME 71-1 Consists from flush mounting case with frame and attachment screw, to SecuriFire indication and control panels. Incl. plan box PLB For 1 MIC and plan box Dimensions (H x D x W): Spare Parts: 357x617x90 mm Flush mounting kit for MIC711 Description Type Art. Nr. Frame for flush mounting equip. FFM Flush Mounting Case FMC Plan box PLB FME 73-1 Consists from flush mounting case with frame and attachment screw, to SecuriFire / SecuriSafe indication and control panels. For 1 MIC or 2 small operating device Dimensions (H x D x W): Spare Parts: 357x251x90 mm Description Type Art. Nr. Frame for flush mounting equip. FFM Flush Mounting Case FMC Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

29 3. SecuriFire 2000 Units Every SecuriFire 2000 basic version includes the central processor unit B6-BCB 13 and the power supply unit B6-PSU. The units B4 / B6-XXX must be equipped on the addition slot. All plugs are enclosed. B6-LXI2 Loop I/F, LAN I/F board B6-LXI2 For connecting a further two addressable loops with detectors and modules featuring SecuriLine extended addressable loop technology to the SecuriFire Alternatively one addressable loop and two stub lines or four stub lines can also be connected. The unit also has a LAN interface. This means that all the options of a LAN interface can be used even with 4 loops. The unit is fitted to the main control unit B6-BCB13. Output voltage: 30 V DC ±3% Power consumption: 31 ma Transmission type: Start-stop operation, 8 data bits Transmission rate: bit/s Direction: bidirectional Physical characteristics: 16-pin plug-in screw terminal RM 3,81 Ambient temperature: -0 C to +50 C RS 485 / 100 Base TX I/F board, 2x RS485, 1x 100Base-TX B6-NET2-485 For redundant networking of SecuriFire 2000 control panels or for redundant connection of PC applications. The module consists of 2 network connectors (RS 485 interface) and one 100 Base TX interfaces. The module is connected to the B6-BCB 13 main processor unit. EG Supply voltage: Power consumption: Ambient temperature: Transmission type: Physical characteristics: Direction: LAN- interfaces: Speed: Distance: RS485-interfaces: internally via the system BUS 53 ma 0 C to +50 C TCP / IP 5 x RJ-45 sockets - 8 pole g bidirectional, full-duplex 1x Ethernet 100 Base TX max. 100Mbit/s max. 100m 2 x RS485 with redundant cabling, of which 1 galvanically isolated Speed: max Mbit/s Distance: max. 1200m Cable: UTP Cat 5 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

30 LAN I/F board, 1x 100Base-TX B6-LAN For non-redundant networking of SecuriFire FCP 2000 control panels for non-redundant connection of PC applications. The module is connected to the B6-BCB 13 main processor unit. EG Supply voltage: Power consumption: Ambient temperature: Transmission type: Physical characteristics: Direction: LAN- interfaces: Speed: Distance: internally via the system BUS 0 ma 0 C to +50 C TCP / IP 1x RJ-45 sockets, 8 pole bidirectional, full-duplex 1x Ethernet 100 Base TX max. 100Mbit/s max. 100m B4-USI Univ. Serial I/F B4-USI The B4-USI is a universal communication unit and serves to connect SecuriFire 2000 to management systems and to actuate external printers, pagers, ComBOX, telephone servers, etc. The link to management systems is line type. The selection of operation mode of the interface pair parameters is performed by programming. EG Supply voltage: Power consumption: Ambient temperature: Range: Transmission type: Baud rate: Interface type: Interfaces X2 and X4 Interface X3 intern via System BUS 21 ma 0 C to +50 C RS 485, RS 422 = 1200m RS 232 = 15m asynchronous serial 57,6 kbaud RS485, RS422 or RS232 0A/1A (RS485, RS422 or RS232) PCMCIA slot (not supported) 30 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

31 RS 485 / 100 Base TX I/F board, 2x RS485 FXS, 2x 100Base-TX B6-NET2-FXS For redundant networking of SecuriFire 2000 control panels or for redundant connection of PC applications. The module consists of 3 network connectors (1 x RS 485 interface, 2 x FXS) and one 100 Base TX interface. The module is connected to the B6-BCB 13 main processor unit Supply voltage: Power consumption: Ambient temperature: Transmission type: Physical characteristics: Direction: LAN- interfaces: internally via the system BUS 99 ma -5 C to +50 C TCP/IP RJ-45 connector, 8-pin Bidirectional, full-duplex Ethernet 100BASE-TX RS 485 / 100 Base TX I/F board, 2x RS485 FXM, 2x 100Base-TX B6-NET2-FXM For redundant networking of SecuriFire 2000 control panels or for redundant connection of PC applications. The module consists of 3 network connectors (1 x RS 485 interface, 2 x FXM) and one 100 Base TX interface. The module is connected to the B6-BCB 13 main processor unit Supply voltage: Power consumption: Ambient temperature: Transmission type: Physical characteristics: Direction: LAN- interfaces: internally via the system BUS 122 ma -5 C to +50 C TCP/IP RJ-45 connector, 8-pin Bidirectional, full-duplex Ethernet 100BASE-TX RS 485 / 100 Base TX I/F board, 4x FX(S/M), 1x TX B9-NET-FX4 For redundant networking of SecuriFire 2000 control panels or for redundant connection of PC applications. The module consists of 4 network connectors (4xFX(S/M)) and one 100 Base TX interface. The module is connected to the B6-BCB13 main processor unit Supply voltage: Power consumption: Ambient temperature: Transmission type: Physical characteristics: Direction: LAN- interfaces: internally via the system BUS 87 ma + 30 ma for each GBIC -5 C to +50 C TCP/IP RJ-45 connector, 8-pin Bidirectional, full-duplex Ethernet 100BASE-TX Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

32 B6-EIO input/output module B6-EIO The B6-EIO Unit includes 10 monitored inputs and 8 monitored outputs as well as the control electronics for the LED indication panel, which is built into the door of every SecuriFire ECP/FEP The unit was developed for standards-compliant actuation of an extinguishing area. However, in accordance with its features, it can also be used in other ways Supply voltage: internally via the system BUS Power consumption: 31 ma Connection: 10 detection zones (up to 30 detectors / zone) Max. line resistance Ambient temperature: Addressable: Distance: max. 50 Ω -5 to +50 C not possible max m 32 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

33 Boards SecuriFire All modules and components of the SecuriFire system are redundant for system availability reasons, which also guarantee in the event of a fault that indication information, signal processing and the controlling of all connected fire alarm devices is ensured. Slot Allocation The module rack of every SecuriFire 3000 always contains 1. Main Control Board B5-MCB15 placed in slot 1 2. Power Supply Unit B5-PSU in slot If anyone of the B5 LAN, B5-NET2-485 or B5-NET4-485 modules is used, it must be placed in slot 2 4. Slots 11 to 13 are solely for relay modules B3-REL10/16/16E. The terminal blocks for the relay boards need to be ordered separately. Using any of the slots 11 to 13 requires that slot nine is not left free. Anyone of the boards B5-BAF or B5-MRI16 must be connected to slot Slots 3 to 9 are for all other boards. Slot 9 needs to be equipped in order to enable slots 11 to 13. Control board B5-BAF For connecting fire brigade control panels, transmission equipment (main detectors), alarm systems (sirens) and for controlling the relay bus. The module also controls an interface for the MMI-BUS (bus for external devices) to which external operating panels, a fire brigade operating panel and other devices are connected. Power supply: Current consumption: internally via the system BUS typically 30 ma with output controller turned on without peripheral current Ambient temperature: 0 to +50 C Relay bus interface: for B3-REL10 or B3-REL16(E) Interface FBP (DIN14661): 12 pin connectable screw clip plug Transmission type: parallel, bidirectional Range: max. 5 m OM1 interface: Transmission equipment or monitored output, 26 V/1.5 A OM2 interface: monitored output, 26 V/1.5 A OM1 interface: Transmission equipment or monitored max m MMI-BUS interface: galvanically isolated RS 485 max m EG Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

34 Control board B8-BAF For connecting fire brigade control panels, transmission equipment (main detectors), alarm systems (sirens) and for controlling the relay bus. The module also controls an interface for the MMI-BUS (bus for external devices) to which external operating panels, a fire brigade operating panel and other devices are connected. Power supply: Current consumption: internally via the system BUS typically 37 ma with output controller turned on without peripheral current Ambient temperature: 0 to +50 C Relay bus interface: for B3-REL10 or B3-REL16(E) Interface FBP (DIN14661): 12 pin connectable screw clip plug Transmission type: parallel, bidirectional Range: max. 5 m OM1 interface: Transmission equipment or monitored output, 26 V/1.5 A OM2 interface: monitored output, 26 V/1.5 A OM1 interface: Transmission equipment or monitored max m MMI-BUS interface: galvanically isolated RS 485 max m Relay construction: bistable Max. Switching surge: 30 VAC /30VDC Max. Switching current: 3A both poles routed to terminals Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

35 Loop Board, 2 Loops, SecuriLine extended B5-DXI2 For connecting two addressable loops with detectors and modules featuring SecuriLine extended addressable loop technology to the SecuriFire Alternatively one addressable loop and two stub lines or four stub lines can also be connected. EG Power supply: internally via the system BUS Current consumption: ca. 35 ma typ. Ambient temperature: 0 to +50 C Elements: 2 Loop circuits, each with max. 250 devices Logical elements: max. 750 per B5-DXI2 Short circuit isolator: integrated into detectors and controller modules Individual detector identification: integrated as standard Cable: 1 x 2 x 0,8 mm shielded (Standard) Loop length: max m Max. line resistance: 255 Ω Loop Board, 8 stub lines, SecuriLine extended B8-SXI8 For connecting eight addressable stub lines with detectors and modules featuring SecuriLine extended addressable technology to the SecuriFire Power supply: internally via the system BUS Current consumption: ca. 43 ma typ. Ambient temperature: 0 to +50 C Elements: 8 stub lines with max. 250 devices Logical elements: max. 512 per B8-SXI8 Short circuit isolator: integrated into detectors and controller modules Individual detector identification: integrated as standard Cable: 1 x 2 x 0,8 mm shielded (Standard) Stub line length: max m Max. line resistance: 75 Ω Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

36 RS 485 / 100 Base TX I/F board, 2x RS485, 2x 100Base-TX B5-NET2-485 For redundant networking SecuriFire control panels or for redundant connection of PC applications. The module consists of two network connectors (RS 485 interface) and two 100 Base TX interfaces. On the front side there are 6 RJ 45 sockets for connecting from the sub control unit network and to the Ethernet. System configuration hint:the module can only be fitted in connection slot 2 in the module rack. EG Power supply: Current consumption: Transmission type: Physical characteristics: Direction: LAN- interfaces: Speed: Distance: RS485-interfaces: Speed: Distance: Cable: internally via the system BUS 120 ma TCP/IP 6 x RJ-45 sockets - 8 pole bidirectional, full-duplex 2 x Ethernet 100 Base TX max. 100 Mbit/s max. 100 m 2 x RS485 with redundant cabling of which 1 galvanically isolated max. 2,5 Mbit/s max m UTP Cat5 RS 485 / 100 Base TX I/F board, 2x RS485, 2x 100Base-TX B8-NET2-485 For redundant networking SecuriFire control panels or for redundant connection of PC applications. The module consists of two network connectors (RS 485 interface) and two 100 Base TX interfaces. On the front side there are 6 RJ 45 sockets for connecting from the sub control unit network and to the Ethernet. System configuration hint: The module can only be fitted in connection slot 2 in the module rack Power supply: Current consumption: Transmission type: Physical characteristics: Direction: LAN- interfaces: Speed: Distance: RS485-interfaces: Speed: Distance: Cable: internally via the system BUS 120 ma TCP/IP 6 x RJ-45 sockets - 8 pole bidirectional, full-duplex 2 x Ethernet 100 Base TX max. 100 Mbit/s max. 100 m 2 x RS485 with redundant cabling of which 1 galvanically isolated max. 2,5 Mbit/s max m UTP Cat5 36 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

37 RS 485 / 100 Base TX I/F board, 4x RS485, 2x 100Base-TX B5-NET4-485 For redundant networking of SecuriFire control panels or for redundant connection of PC applications. The module consists of four network connectors (RS 485 interface) and two 100 Base TX interfaces. On the front side there are 10 RJ45 sockets for connecting from the sub control unit network and to the Ethernet. System configuration hint: The module can only be fitted in connection slot 2 in the module rack. EG Power supply: Current consumption: Transmission type: Physical characteristics: Direction: LAN- interfaces: Speed: Distance: RS485-interfaces: Speed: Distance: Cable: internally via the system BUS 127 ma TCP/IP 10 x RJ-45 sockets - 8 pole bidirectional, full-duplex 2 x Ethernet 100 Base TX max. 100 Mbit/s max. 100 m 4 x RS485 with redundant cabling of which 2 galvanically isolated max. 2,5 Mbit/s max m UTP Cat5 RS 485 / 100 Base TX I/F board, 4x RS485, 2x 100Base-TX B8-NET4-485 For redundant networking of SecuriFire control panels or for redundant connection of PC applications. The module consists of four network connectors (RS 485 interface) and two 100 Base TX interfaces. On the front side there are 10 RJ45 sockets for connecting from the sub control unit network and to the Ethernet. System configuration hint: The module can only be fitted in connection slot 2 in the module rack Power supply: Current consumption: Transmission type: Physical characteristics: Direction: LAN- interfaces: Speed: Distance: RS485-interfaces: Speed: Distance: Cable: internally via the system BUS 127 ma TCP/IP 10 x RJ-45 sockets - 8 pole bidirectional, full-duplex 2 x Ethernet 100 Base TX max. 100 Mbit/s max. 100 m 4 x RS485 with redundant cabling of which 2 galvanically isolated max. 2,5 Mbit/s max m UTP Cat5 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

38 RS 485 / 100 Base TX I/F board, 2x RS485 FXS, 2x 100Base-TX B5-NET2-FXS For redundant networking of SecuriFire 3000 control panels or for redundant connection of PC applications. The module consists of 5 network connectors (1 x RS 485 interface, 4x GBIC FX (S/M)) and one 100 Base TX interface. System configuration hint: The module can only be fitted in connection slot 2 in the module rack Power supply: internally via the system BUS Current consumption: 194 ma + 30 ma for each GBIC Transmission type: TCP/IP Physical characteristics: individual per GBIC Direction: bidirectional LAN- interfaces: Ethernet 100 Base TX Transmission type: TCP/IP Direction: Bidirectional, full-duplex operation Protection: EMC and ESD with high-voltage capacitors Mechanical design: RJ-45 connector, 8-pin RS485-interfaces: 4 x RS485 with redundant cabling of which 2 galvanically isolated Speed: max. 2,5 Mbit/s Distance: max m Cable: UTP Cat5 RS 485 / 100 Base TX I/F board, 2x RS485 FXM, 2x 100Base-TX B5-NET2-FXM For redundant networking of SecuriFire 3000 control panels or for redundant connection of PC applications. The module consists of 8 network connectors (1 x RS 485 interface, 2 x FXM) and one 100 Base TX interface. System configuration hint: The module can only be fitted in connection slot 2 in the module rack Power supply: internally via the system BUS Current consumption: 127 ma Transmission type: TCP/IP Physical characteristics: LC 2x5 connector Direction: bidirectional LAN- interfaces: Ethernet 100 Base TX Transmission type: TCP/IP Direction: Bidirectional, full duplex operation Protection: EMC and ESD with high-voltage capacitors Mechanical design: RJ-45 connector, 8-pin RS485-interfaces: RS485. Galvanic separation Transmission type: Differential signal 38 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

39 RS 485 / 100 Base TX I/F board, 4x FX(S/M), 2x RS485, 2x TX B8-NET2-FX4 For redundant networking of SecuriFire 3000 control panels or for redundant connection of PC applications. The module consists of 5 network connectors (4x GIBC FX (S/M)) and one 100 Base TX interface. System configuration hint: The module can only be fitted in connection slot 2 in the module rack Power supply: internally via the system BUS Current consumption: 194 ma + 30 ma for each GIBC Transmission type: TCP/IP Physical characteristics: individual per GIBC Direction: bidirectional LAN- interfaces: Ethernet 100 Base TX Transmission type: TCP/IP Direction: Bidirectional, full duplex operation Protection: EMC and ESD with high-voltage capacitors Mechanical design: RJ-45 connector, 8-pin RS485-interfaces: RS485. Galvanic separation Transmission type: Differential signal RS 485 / 100 Base TX I/F board, 8x FX(S/M), 2x TX B8-NET-FX8 For redundant networking of SecuriFire 3000 control panels or for redundant connection of PC applications. The module consists of 8 network connectors (8x GIBC FX (S/M)) and one 100 Base TX interface. System configuration hint: The module can only be fitted in connection slot 2 in the module rack Power supply: internally via the system BUS Current consumption: 226 ma + 30 ma for each GIBC Transmission type: TCP/IP Physical characteristics: individual per GIBC Direction: bidirectional LAN- interfaces: Ethernet 100 Base TX Transmission type: TCP/IP Direction: Bidirectional, full duplex operation Protection: EMC and ESD with high-voltage capacitors Mechanical design: RJ-45 connector, 8-pin Transmission type: Differential signal Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

40 LAN I/F board B5-LAN For non-redundant networking of SecuriFire control panels and for non-redundant connection of PC applications. Two 8 pole RJ-45 sockets can be found on the front side of the module. System configuration hint: The module can only be fitted in connection slot 2 in the module rack. EG Power supply: Current consumption: Ambient temperature: Transmission type: Physical characteristics: Direction: LAN- interfaces: Speed: Distance: internally via the system BUS 0 ma 0 to +50 C TCP/IP 2 x RJ-45 sockets - 8 pole bidirectional, full-duplex Ethernet 100 Base TX max. 100 Mbit/s max. 100 m Universal I/F board B3-USI4 For connecting SecuriFire sub control units to control systems, for controlling external printers, pagers, ComBOX units, telephone servers etc. A total of 4 redundant, serial, asynchronous interfaces can be used as redundant RS 485 connections in half-duplex mode (for loops) or as nonredundant RS 422 connections in full-duplex mode (for lines). Furthermore, two of the four interfaces can also be operated as RS 232 in full-duplex operation (line) each with 2 control circuits. The selection of each interface s operating mode is done by programming and hardware configuration. System configuration hint: A maximum of five B3-USI4 units can be fitted per sub control unit. Power supply: Current consumption: Ambient temperature: Range: internally via the system BUS 20 ma 0 to +50 C RS 485 = 1200 m RS 232 = 15 m serial, asynchronous 57,6 kbaud 2x2 redundant half-duplex RS 485, also full-duplex operation, galvanically isolated 2 redundant RS232 interfaces, galvanically isolated Transmission type: Baud rate: Interfaces: EG Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

41 Monitored output board B5-OM8 This indicating Circuit Controller is designed for efficient, addressable control of sounders, sirens, bells and strobes. The maximum output current of 1,3 A per output and 3A per block of four lines (1 to 4 and 5 to 8) assures meeting all requirements for signaling devices. The outputs are monitored for short circuits and wire breaks. Note: The total output current of the module depends on the capacity of the power supply unit and overall system load connected to it Power supply: Current consumption: Ambient temperature: Transmission Type: Direction: Physical characteristics: internally via the system BUS 28 ma 0 to +50 C serial bidirectional 96-pin connector Surveyed input board, incl. connector plug B3-IM8 The B3-IM8 is designed to provide an interface between conventional detectors and the SecuriFire panel. It enables the panel to use each of the eight channels individually to monitor the presence and operation of up to 32 conventional detectors per channel (max. 256 detectors) monitor the presence and operation of up to 10 Ex detectors in intrinsically safe applications using Z787 safety barriers monitor proper operation of an activated device such as valves, doors etc... Allows for VdS compliant monitoring of extinguishing devices. Designed and approved for Hekatron 130 Series and specific Hochiki Ex rated detectors. Please refer to the product data sheet for related information. The inputs are supervised for open and short circuits. Each channel / input is individually programmable and configurable using configuration software and on-board jumpers. EG Power supply: Current consumption: Quiescent: Alarm Threshold: Ambient temperature: Connection: internally via the system BUS 9 ma 10mA -5 to +50 C 8 detector zones / monitored inputs Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

42 Alarm line board for detectors series 140 B3-LEE23 For connecting up to 8 stub lines each with a maximum of 30 series 140 detectors. A maximum of five B3-LEE23 modules can be fitted to connection slots 2 to 8 of a SecuriFire module rack, however this module is only permitted for use in cases where the system is being reconditioned due to the terms of the approvals of the module. EG Power supply: internally via the system BUS Current consumption: 22 ma Ambient temperature: 0 to +50 C Detector zones: max. 8 logical detector zones per stub line Addressing: the hardware address assigned to the detector can be assigned whatever logical Wiring length: max m Alarm loop board for detectors series 150 B3-LEE24 Refurbishing module for old installations based on HX 150 detectors. Provides 4 addressable loops supporting HX protocol and 127 HX 150 detectors each. System configuration hint: A maximum of five B3-LEE24 modules can be plugged in slots 2 to 8 of the SecuriFire module rack. EG Power supply: internally via the system BUS Current consumption: 27 ma Ambient temperature: 0 to +50 C Devices/Elements: 4 loop circuits each with max. 127 devices Addressing: the hardware address assigned to the detector can be assigned whatever logical software address is required Range: max m 42 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

43 Direct current technique board (Detector series Hochiki) B3-DCI6 The B3-DCI6 is used for supplying and evaluating up to 6 inputs, which can be set either as detector zones using DC technology, as monitored inputs or as extinguisher inputs (e.g. VdS extinguishing interface, primary inputs, valve monitoring etc.) via jumper caps and via programming. It is possible to differentiate between a maximum of ten detector areas by means of an optional 3 core wiring system. EG Relay I/F board Power supply: internally via the system BUS Power consumption: 7 ma Line voltage: 22V to +30V Line current: 30 ma max. current limited Terminal resistance: 11.8 kω Alarm resistance: 560 Ω Line resistance: Max Ω per core B5-MRI16 (delivered with connectors front screw) The module offers 16 bi-stable, freely programmable 24 V/3 A relay contacts. Whether a contact is Normally Open (NO) or Normally Closed (NC) is software configurable. By programming a fail-safe position the status of every individual relay can be defined in the event of a supply voltage failure or the fire alarm control panel being switched off. The B5-MRI16 can be fitted in any of the slots 2-9 of the SecuriFire module rack. System configuration hint: The B5-MRI16 is able to drive the expansion bus (slots 11 to 13) when placed in slot 9. Doing so will allow you to run relay modules of type B3- REL10, B3-REL16 and B3-REL16E plugged in slot 11 to 13. Power supply: internally via the system BUS/Relay BUS Current consumption: 6 ma typ. (battery current) Ambient temperature: -5 to +50 C Relay construction: bistable Contact resistance: 30 mω Maximum switching surge: 30 VAC/ 30 VDC Max. switching current: 3A both poles routed to terminals Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

44 Relay board with 230V contacts B3-REL10 (delivered with connectors front screw) The module contains 10 bi-stable, freely programmable 230 V/3 A relay contacts. Whether a contact is a make contact or a break contact is ascertained by configuration using software. By programming a fail-safe position the status of every individual relay can be defined in the event of a supply voltage failure or the fire alarm control panel being switched off. A module of type B5-BAF or B5-MRI16 must be fitted to connection slot 9 of the SecuriFire module rack for controlling the relay. System configuration hint: The B3-REL10 can only be used in slot 11 to Power supply: internally via the system BUS/Relay BUS Ambient temperature: -5 to +50 C Relay construction: bistable Contact resistance: 30 mω Maximum switching surge: 230 VAC/ 125 VDC Max. switching current: 3A both poles routed to terminals Relay board with 24V contacts B3-REL16 (delivered with connectors front screw) The module contains 16 bi-stable, freely programmable 24 V/3 A relay contacts and is used for controlling sirens, holding magnets, relays etc. Whether the contact is a make or break contact is determined by software-based programming. By programming a fail-safe position the status of every individual relay can be defined in the event of a supply voltage failure or the fire alarm control panel being switched off. A module of type B5-BAF or B5-MRI16 must be fitted to connection slot 9 of the SecuriFire module rack for controlling the relays. System configuration hint: The B3-REL16 can only be used in slot 11 to Power supply: internally via the system BUS/Relay BUS Ambient temperature: -5 to +50 C Relay construction: bistable Contact resistance: 30 mω Maximum switching surge: 30 VAC/ 30 VDC Max. switching current: 3A both poles routed to terminals 44 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

45 Relay board with fused 24V outputs B3-REL16E (delivered with connectors front screw) Identical to module B3-REL16 in terms of technical specifications and function, but with additional fused relay contacts (the fuses are not monitored) and resistors (3.3kΩ monitoring resistance and 680 Ω working resistance) for use as a VdS extinguishing interface. Using jumpers it is possible to choose between normal relay contacts and VdS interfaces. System configuration hint: The B3-REL16E can only be used in slot 11 to SecuriFire 3000 Plug-in Modules Accessories: Power supply: internally via the system BUS/Relay BUS Ambient temperature: -5 to +50 C Relay construction: bistable Contact resistance: 30 mω Maximum switching surge: 30 VAC/ 30 VDC Max. switching current: 3A both poles routed to terminals Contact protection: Micro Fuse 3,15 A SLOW Description Type Art. Nr. I/F converter ADAM 4520 FG Plastic box for UIO UIO GEH FG69041 Steel plate for module UIO UIO STP FG05203 Connection cable with connector 34 pin B3 UIO KAB34 FG81725 Connection cable with connector 40 pin B3 UIO KAB40 FG81726 Pluggable Terminal Block (set of 2) for REL10 front screw ST-SET REL Pluggable Terminal Block (set of 2) for REL16/16E, MRI, front screw ST-SET REL Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

46 5. SecuriLine extended Modules Single Detector I/F for alarm transmission SDI 82X-1 (MCP or other contacts) Addressable I/O module typically connected to Manual Call points (MCP), Pull Stations, Smoke Switches or Door monitors. For SecuriLine extended. Provides 3 inputs and 1 output, freely programmable Operating voltage: 12 to 30 V DC Current draw, constant: 300 μa Ambient temperature: -25 C to +70 C Colour: white Dimensions (H x W x D): 32 x 22 x 14 mm VdS-Approval: G Single Detector I/F SDI 81X/1-1 3 Inputs 2 Outputs Addressable I/O module typically connected to Manual Call points (MCP), Pull Stations, Smoke Switches or Door monitors. For securiline extended With emergency alarm transmission. Operating voltage: 12 to 30 V DC Current draw, constant: 300 μa Ambient temperature: -25 C to +70 C Colour: white Dimensions (H x W x D): 32 x 22 x 14 mm VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

47 In-/Output Module BX-OI3 Contains a relay output with a programmable fail-safe position, two inputs for monitored querying of potential-free contacts and an optocoupler input for monitoring external voltages. In addition, the voltage on the loop circuit is internally monitored for low voltage. The BX-OI3 is particularly well-suited for connecting special detectors (flame and line detectors, smoke aspirating systems etc.). Both the addressing of the module and the setting of parameters for connected special detectors (e.g. how they behave when there is an alarm or a fault) is carried out via the fire alarm control panel using PC software. An IP 66 protection class plastic case is used for fitting the module, which can be fitted with various different cable inlets as required. Shipped including 4,180 Ohm resistors for the monitored inputs. Operating voltage: 12 to 30 V Power consumption: typ. 550 μa Signal transmission: serial, 2 wire technology Relay output: bistable change-over contact 230 V/2A(max. 60W) Monitored inputs: for potential-free contacts Optocoupler input: Querying of potentially-bound signals, or external voltages from 0 to 30 VDC Connection: screw clips, maximum 1.5 mm² Short circuit isolator: integrated Protection class: IP 66 with case Ambient temperature: -20 to +60 C Rel. air humidity: 5 to 95% without condensation Dimensions(H x W x D): 67 x 67 x 20 mm with case: 94 x 94 x 57 mm Case: Polystyrol, halogen-free Colour: grey RAL 7035 VdS-Approval: G Note: The box GEH MOD IP66 must be ordered separately See accessories for loop modules Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

48 Advanced Input Module BX-AIM Can be configured as a monitored input for querying potential-free contacts or as a collectively addressable detector zone (DC technology). The monitored input can, if required, be used as a standard extinguishing interface in accordance with VdS directives, and furthermore a balancing function of the fault thresholds for the quiescent current level is also possible (pursuant to EN or VdS 2489). By interconnecting a Zener barrier and by using intrinsically safe detectors it is also possible to monitor hazardous areas. An IP 66 protection class plastic case is used for fitting the module, which can be fitted with various different cable inlets as required. Supplied including an alarm resistor (560 Ohm) and a terminating resistor (19k1). Operating voltage: 10 to 29 VDC (from the loop circuit) Power consumption: without DC branch: Type 6500 µa with DC branch: Type µa Signal transmission: serial, 2 wire technology Function: DC branch module, monitored input Connection: screw clips, maximum 1.5 mm² Short circuit isolator: integrated Protection class: IP 66 with case Ambient temperature: -20 to +60 C Rel. air humidity: 5 to 95%, without condensation Dimensions(H x W x D): 67 x 67 x 20 mm with case: 94 x 94 x 57 mm Case: Polystyrol, halogen-free, Colour: grey RAL7035 VdS-Approval: G Accessories: Description Type Art. No. Ex-i end of line resistor 19k1 for module AIM EOL Ex 19k Note: The box GEH MOD IP66 must be ordered separately See accessories for loop modules Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

49 Monitored Output Module BX-IOM For controlling monitored devices, which are supplied with power by an external power supply (e.g. sirens etc.). The module contains a short circuite resistant monitored output (suitable for continuous operation of fur a configurable pulse emmision with emission time limitation) and galvanically isolated input which can be used either as a voltage on the loop circuite is internally monitored for undervoltage. Both the addressing of the module an the setting of its parameters, which are set seperatly for every input, are carried out using PC software via the fire alarm control panel. Operating voltage: 12 to 30 V Power consumption: 430 μa Signal transmission: serial, 2 wire technology Function: 1 short circuit resistant monitored output; 1 optocoupler input Connection: screw clips, maximum 1.5 mm² Monitored output: Loads of 20 Ω to 1kΩ, 3 load ranges Output current: max. 1,3 A short circuit resistant Quiescent current: 1 to 15 ma can be set using software Optokoppler input: IM1+: 20-30V VEXT: 20-30V Short circuit isolator: integrated Protection class: IP 66 with case Ambient temperature: -20 to +60 C Rel. air humidity: 5 to 95% without condensation Dimensions(H x W x D): 67 x 67 x 20 mm with case: 94 x 94 x 57 mm Case: Polystyrol, halogen-free Colour: grey RAL 7035 VdS-Approval: G Note: The box GEH MOD IP66 must be ordered separately See accessories for loop modules Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

50 Relay Output Module BX-REL4 Provides for four potential free relay outputs with a contact rating of 230V. Each relay allows for COMMON, NORMALLY OPEN and NORMALLY CLOSED contacts. Each input is freely programmable using SecuriFire Studio. The module is also suitable for emitting switching impulses. The relay outputs can be switched to a fail-safe position in the event of voltage loss on the loop circuit, and the voltage on the loop circuit is also internally monitored for under voltage. It fits nicely in the IP 66 rated enclosure listed below which allows for different cable inlets. Operating voltage: 12 to 30 V Power consumption: typ. 510 μa Signal transmission: serial, 2 wire technology Function: 4 potential-free relay outputs Connection: screw clips, maximum 1.5 mm² Relay output connection: screw clips, maximum 2.5 mm² Length of wires: max. 100 m Short circuit isolator: integrated Protection class: IP 66 with case Ambient temperature: -20 to +60 C Rel. air humidity: 5 to 95% without condensation Relay output: bistable change-over contact 230 V/2 A Switching power: 60 W (230 V, 0.25 A) Switching frequency: max Hz Pulse emission: 200 ms- 25 s in 100 ms intervals: Dimensions(H x W x D): 67 x 67 x 20 mm with case: 130 x 94 x 57 mm Case: Polystyrol, halogen-free Colour: grey RAL 7035 VdS-Approval: G Note: The box GEH MOD IP66 must be ordered separately See accessories for loop modules Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

51 Monitored Input Module BX-IM4 For indication and monitoring of various types of acknowledgements, e.g. door contacts, fire zones, extinguishing systems, sprinkler messages, etc. The module contains 4 inputs for monitored and non-monitoring querying of potential-free contacts, which are suitable for processing switching states of longer than 330ms. Both the addressing of the module and the setting of its parameters, which are set separately for every input, are carried out using PC software via the fire alarm control panel. An IP 66 protection class plastic case is used for fitting the module, which can be fitted with various different cable inlets as required. Operating voltage: 12 to 30 V Power consumption: typ. 450 μa Signal transmission: seriell, 2-Leiter-Technik Function: 4 inputs for monitored or non-monitored querying of potential-free contacts Connection: screw clips, maximum 1.5 mm² Short circuit isolator: integrated Protection class: IP 66 with case Ambient temperature: -20 to +60 C Rel. air humidity: 5 to 95%, without condensation Dimensions(H x W x D): 67 x 67 x 20 mm with case: 94 x 94 x 57 mm Case: Polystyrol, halogen-free Colour: grey RAL 7035 VdS-Approval: G Note: The box GEH MOD IP66 must be ordered separately See accessories for loop modules Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

52 End Position Switch Module BX-ESL End position switch for deployment in sprinkler monitoring and for blocking systems. The module contains an optical light barrier which measures the movement of an activation plunger. The cables are fed into the unit using PG connection joints, with connection to the loop module being via 3 screw-type terminals. Both the addressing of the module and the setting of its parameters are carried out using PC software via the fire alarm control panel. The BX- ESL is fitted in a plastic case with IP 65 protection class and is delivered incl. 2 connection joints Operating voltage: 12 to 30 V Power consumption: typ. 400 μa Signal transmission: serial, 2 wire technology Function: 1 optical light barrier Response Time: 500 ms Connection: screw clips, maximum 1.5 mm² Short circuit isolator: integrated Protection class: IP 65 with case Ambient temperature: -20 to +60 C Rel. air humidity: 5 to 95%, without condensation Dimensions(H x W x D): 58 x 58 x 34 mm with case Case: PA-Taromid (Thermoplastic) Colour: case red RAL 3016 cover black RAL 9005 VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

53 In-/Output Module BX-O2I4 The BX-O2I4 has two relay outputs and four monitored inputs for polling potential-free contacts. The individual I/O functions can be configured differently and combined so that this module can be used, for example, for the integration of fire protection flaps with feedback. Addressing and parameter assignment for the BX-O2I4 is performed with PC software via the fire alarm control panel. The module includes a short-circuit isolator. In the event of wire breakage or a short-circuit, this functionality ensures that the fault is localised and at the same time maintains the full operability of the addressable loop. Operating voltage: 12 to 30 V Power consumption: typ. 630 μa Signal transmission: serial, 2 wire technology Relay output: bistable change-over contact 230 V/2A(max. 60W) Monitored inputs: for potential-free contacts Optocoupler input: Querying of potentially-bound signals, or external voltages from 0 to 30 VDC Connection: screw clips, maximum 1.5 mm² Short circuit isolator: integrated Protection class: IP 66 with case Ambient temperature: -20 to +60 C Rel. air humidity: 5 to 95% without condensation Dimensions(H x W x D): 67 x 67 x 20 mm with case: 130 x 94 x 57 mm Case: Polystyrol, halogen-free Colour: grey RAL 7035 VdS-Approval: G Note: The box GEH MOD2 IP66 must be ordered separately See accessories for loop modules Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

54 Relay Output Module BX-O1 Provides one potential free relay outputs with a contact rating of 230V. Each input is freely programmable using SecuriFire Studio. The module is also suitable for emitting switching impulses. The relay output can be switched to a fail-safe position in the event of voltage loss on the loop circuit, and the voltage on the loop circuit is also internally monitored for under voltage. It fits nicely in the IP 66 rated enclosure listed below which allows for different cable inlets. Operating voltage: 12 to 30 V Power consumption: typ. 480 μa Signal transmission: serial, 2 wire technology Function: 1 potential-free relay output Connection: screw clips, maximum 1.5 mm² Relay output connection: screw clips, maximum 2.5 mm² Length of wires: max. 100 m Short circuit isolator: integrated Protection class: IP 66 with case Ambient temperature: -20 to +60 C Rel. air humidity: 5 to 95% without condensation Relay output: bistable change-over contact 230 V/2 A Switching power: 60 W (230 V, 0.25 A) Switching frequency: max Hz Pulse emission: 200 ms- 25 s in 100 ms intervals: Dimensions(H x W x D): 67 x 67 x 20 mm with case: 130 x 94 x 57 mm Case: Polystyrol, halogen-free Colour: grey RAL 7035 VdS-Approval: G Note: The box GEH MOD IP66 must be ordered separately See accessories for loop modules Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

55 Monitored Input Module BX-I2 For indication and monitoring of various types of acknowledgements, e.g. door contacts, fire zones, extinguishing systems, sprinkler messages, etc. The module contains 2 inputs, one for monitored and nonmonitoring querying of potential-free contacts, which is suitable for processing switching states of longer than 330ms and one optocoupler input for monitoring external voltages. Both the addressing of the module and the setting of its parameters, which are set separately for every input, are carried out using PC software via the fire alarm control panel. An IP 66 protection class plastic case is used for fitting the module, which can be fitted with various different cable inlets as required. Operating voltage: Power consumption: Signal transmission: Function: Connection: Short circuit isolator: Protection class: Ambient temperature: Rel. air humidity: Dimensions(H x W x D): Case: 12 to 30 V typ. 460 μa serial, 2 wire technology 1x monitored or non-monitored input 1x Optocoupler input screw clips, maximum 1.5 mm² integrated IP 66 with case -20 to +60 C 5 to 95%, without condensation 67 x 67 x 20 mm with case: 94 x 94 x 57 mm Polystyrol, halogen-free Colour: grey RAL 7035 VdS-Approval: G Note: The box GEH MOD IP66 must be ordered separately See accessories for loop modules Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

56 Radio Gateway BX-RGW SPU 6002 BX-RGW SPU 6002 (loop interface incl. housing) (radio interface) Communications interface between the fire alarm control panel and the DOW 1171 and SMF 6120 radio controlled smoke detectors. Up to 30 radio controlled smoke detectors can be connected to one gateway. If the radio connection between the detector and the gateway is briefly interrupted, then a diversion via the neighboring detector will be automatically established to the next gateway. Both the addressing of the module and the setting of its parameters are carried out via the fire alarm control panel. The radio gateway is supplied via the loop. The additional 9 V battery guarantees the operation during commissioning or when the detector bus is dead. In normal operating condition the battery is switched off which leads to a service life of well over 5 years. The radio interface board SPU 6002 plugs into the BX- RGW. Please order both assemblies for completing a radio base unit. Operating voltage: 12 to 30 V Power consumption: typ. 950 μa Wireless module interface: 20 pin 2 rowed multipoint connector Buffer battery: 9V Lithium/ Manganese (lifespan>5 years) Frequency range: 868 to 870 MHz Transmission strength: max. 5 mw No. of connectible detectors: max. 30 Range in buildings: up to 40 metre where there is intervisibility Aerial: integrated, separate transmitter and receiver aerials Protection class: IP 54 with case Ambient temperature: -10 to +55 C Rel. air humidity: 5 to 95% without condensation Dimensions(H x W x D): 93 x 70 x 24 mm with case: 120 x 80 x 24 mm Case: Polystyrol, halogen-free Colour: grey RAL 7035 VdS-Approval: G FG Accessories: Description Type Art. No. Battery for Radio Transmitter BATT FM FG Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

57 Magnetic Door holder with Door magnet support AFS 55 BX-MDH (delivered without Battery) The BX-MDH is an electronically triggered magnetic door holder for connection to the SecuriLine extended. It has a permanent magnet which fixes the fire protection doors in the open state in normal operation without requiring electrical energy. If there is a fire alarm or a fault, a brief current pulse neutralises the magnetic field and the fire protection doors close Operating voltage: V Operating current Quiescent (max.): 550 µa Power consumption: 2,1 W Fault: Door is open 340 µa Door is closed 120 µa Magnetic holding area: Ø 48 mm Max. Holding strength: 200 N Buffer battery: Lithium (lifespan > 5 years) 9 V Protection class: IP 42 Ambient temperature: -20 C to +60 C Dimensions(H x W x D) : 85 x 142 x 40 mm Colour: grey RAL 7035 Weight: 0,6 Kg VdS-Approval: not available Accessories: Description Type Art. No. Door magnet support BX-MDH ASS Adjustable door magnet support for BX-MDH AFS Lithium Battery 9V Battery U9 VL-J Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

58 Multiple Detector I/F BX-MDI8 The BX-MDI8 has 8 monitored inputs for connecting detection zones or for polling potential-free contacts. The module requires a redundant, external power supply for operation. Addressing and parameter assignment for the BX-MDI8 is performed with PC software via the fire alarm control panel. The module includes a short-circuit isolator. In the event of wire breakage or a short-circuit, this functionality ensures that the fault is localized and at the same time maintains the full operability of the addressable loop. Operating voltage:: 12 to 30 V Power consumption: 450 µa Signal transmission: Serial data transmission, 2-line technology Connection: Screw terminals max. 1.5 mm2 Protection type: 66 IP with map case Ambient temperature: -20 C to +60 C Humidity ambient condition: 5 to 95 %, without condensation Dimensions (H x W x D): 80 x 151 x 20mm with case: 94 x 180 x 57mm Weight: 125g VdS-Approval: in process Note: The box GEH MOD3 IP66 must be ordered separately See accessories for loop modules Input module BX-SCU For an addressable stub line installation within a SecuriLine extended. Up to 32 devices can be connected to the stub line. A maximum of 128 devices per SecuriLine extended with BX-SCU are possible. Operating voltage: 12 to 30 V Maximum power consumption: 470 µa Dimensions (H x W x D): 67 x 67 x 20 mm with case: 94 x 94 x 57 mm Case: Polystyrol, halogen-free Colour: grey RAL 7035 Note: The box GEH MOD IP66 must be ordered separately See accessories for loop modules Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

59 5.1. Accessoires for Loop Modules Accessoires for SecuriLine Modules Description Type Art. Nr. Box for MDI8 GEH MOD3 IP Box for REL4, O2I4 GEH MOD2 IP66 FG Box for Line Modules (except REL4, O2I4) GEH MOD IP66 FG Mounting plate for Line Modules (except REL4, O2I4) MP MOD KL Mounting plate for REL4, O2I4 MP MOD GR Mounting plate for MDI8 MP MOD GR Stepped nipple M20 MM SN M20 MM Twist joint PG11 IP68 MM ANB M16 MM Lock nut M16 MM GM M16 MM Twist joint M12 MM ANB M12 MM Twist joint M20 MM ANB M20 MM Taper M20 - M12 MM RR M20 - M12 MM Taper M25 - M12 MM RR M25 - M12 MM Lock nut M12 MM GM M12 MM Lock nut M20 MM GM M20 MM Lock nut M25 MM GM M25 MM Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

60 6. Addressable Detectors SecuriStar 6.1. SecuriStar SecuriLine extended Multiple sensor detector, smoke, heat and carbon monoxide CCD 573X CCD 573X MC (coloured to RAL) The temperature- and CO-supported smoke sensor provides early detection of smouldering, glowing and open fires with smoke development. - Combined smoke, heat and carbon monoxide (CO) detector according EN 54-5/7/26/29/30 - Optimal sensitivity - False-alarm security through temperature and carbon monoxide-supported smoke alarm evaluation - (2 different Cubus Adaptations) - Technical CO alarm according EN Adjustable technical CO pre-signal Available in different RAL colours Please ask for our table Overview_RALcolours_deenfresitnl.xls Operating voltage: 7 to 31 V DC Current consumption quiescent: 150 µa Current consumption: 20 ma Alarm indicator: LED red External indication: 5V/ 1mA Ambient temperature: 25 C to +50 C Protection class: IP 44 Colour: white Weight: 125 g Dimensions with base Ø x H: x 67.5 mm VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

61 Multiple sensor detector, smoke and heat MCD 573X MCD 573X CP (coated print, for temporarily humid areas) MCD 573X MC (coloured to RAL) Combined smoke and heat detector with programmable detection behaviour smoke / heat or combined. - Dust cap included. - self monitoring of all detector parts - automatic smoke alarm sensitivity through CUBUSleveling - constant sensitivity through dust compensation - built-in short circuit isolator - patented Signature Alarm for smoke and heat - heat detection classes A1, A2, B and indices R&S for all classes - 100% backwards compatible to the STD531 and MCD 573 Messages - separate alarm signalisation for smoke and heat - 2 pre-warning levels for smoke - warning signal for high ambient temperature - contamination level 1 and 2 Settings via SecuriFire - smoke and/or heat part can be temporarily disabled. - smoke sensitivity - programmable control output - heat class and index Available in different RAL colours Please ask for our table Overview_RALcolours_deenfresitnl.xls Operating voltage: 7 to 31 V DC Current consumption quiescent: 150 µa Current consumption: 20 ma Alarm indicator: LED red External indication: 5V/ 1mA Ambient temperature: 25 C to +60 C Protection class: IP 44 Colour: white Weight: 125 g Dimensions with base Ø x H: x 67.5mm VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

62 Multiple sensor detector, smoke and heat, with integrated sounder MCD 573X-S MCD 573X-S MC (coloured to RAL) Multiple sensor detector acoustic For early detection of smouldering and open fires with and without smoke development. Single addressable - Multiple standard use on two parallel channels (smoke/heat) according to EN 54-5, -7 and EN Cubus levelling for automatique adaptation to the environment conditions - Signature alarm for smoke and heat - Smoke pre-signal - Alarm threshold tracing - Selection of heat classes according to EN 54-5; Class A1, A2, B inclusive index R and S for all 3 heat classes - Acustic according EN 54-3, Tonality adjustable in three variable volumes Available in different RAL colours Please ask for our table Overview_RALcolours_deenfresitnl.xls Operating voltage: 12 to 31 V DC Current consumption quiescent: 150 µa Current consumption: 20 ma Alarm indicator: LED red External indication: 5V/ 1mA Sounder volume: 92/81/69 db(a) Ambient temperature: 25 C to +60 C Colour: white Weight: 133 g Dimensions with base Ø x H: x 67.5mm VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

63 Multiple sensor detector, smoke and heat, with integrated sounder for voice MCD 573X-SP MCD 573X-SP MC (coloured to RAL) Multiple sensor detector speech For early detection of smouldering and open fires with and without smoke development. Single addressable - Multiple standard use on two parallel channels (smoke/heat) according to EN 54-5, -7 and EN Cubus levelling for automatique adaptations to the environment conditions - Signature alarm for smoke and heat - Smoke pre-signal - Alarm threshold tracing - Selection of heat classes according to EN 54-5; Class A1, A2, B inclusive index R and S for all 3 heat classes - Acustic according EN 54-3, Tonality adjustable in three variable volumes - Three different vocal and text messages in four languages Available in different RAL colours Please ask for our table Overview_RALcolours_deenfresitnl.xls Operating voltage: 12 to 31 V DC Current consumption quiescent: 150 µa Current consumption: 20 ma Alarm indicator: LED red External indication: 5V/ 1mA Sounder volume: 92/81/69 db(a) Ambient temperature: 25 C to +60 C Colour: white Weight: 133 g Dimensions with base Ø x H: x 67.5mm VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

64 6.2. Addressable Ventilation Duct Detectors SecuriLine extended Air duct detector base set, without detector LKM-Set Housing with transparent cover. For mounting ventilation duct detectors :LKM593X, LKM140, LKM150, and LKM583 on round or rectangular ventilation ducts. Including inlet and outlet pipe. Airflow up to maximum 20 m/s Protection class: IP 54 External dimensions (without pipes): 247 x 135 x 95 mm Ventilation duct diameter ( ): 20 to 100 cm Ventilation duct side length ( ): 15 to 100 cm Air flow speed: 1 to 20 m/s Weight: 485 g Duct Smoke detector SecuriLine extended LKM 593X For early detection of smouldering and open fires with smoke development. For mounting in the LKM-Set, for ventilation ducts. Individually addressable and backwards compatible to SSD 531K. - Signature alarm for smoke - Smoke pre-signal - Alarm threshold trackin Operating voltage: Current consumption quiescent: Operating temperature: Colour: Weight: 7 to 31 V DC max. 150 μa 15 C +60 C white RAL9003 PC /ABS 125 g 64 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

65 6.4. SecuriStar SecuriLine Smoke detector SCD 573 Smoke Criteria Detector equivalent to MCD 573 but factory set to smoke only. Intended for replacing SSD531 and MSD533 in existing installations. For new installations, the MCD573 shall used and field programmed after installation. - addressable - self monitoring of all detector parts - automatic smoke sensitivity through CUBUS-levelling - Pre-warning and alarm level - constant sensitivity through dust compensation - 100% backwards compatible to the SSD531 and MSD533 Operating voltage: 16 to 30 V DC Current consumption quiescent: 460 μa Current consumption: 20 ma Alarm indicator: LED red External indication: 6,8 V/5 ma Ambient temperature: 25 C to +60 C Protection class: IP 44 Colour: white Weight: 125 g Dimensions with base Ø x H: 118 x 67.5mm VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

66 Temperature detector TCD heat class A TCD heat class A TCD heat class B Temperature Criteria Detector equivalent to MCD 573 but factory set to heat only and to a specific heat class. Intended for replacing UTD531 in existing installations. For new installations, the MCD573 shall used and field programmed after installation. - addressable - false alarm resistant alarm evaluation - fixed threshold and rate-of-rise capabilities Operating voltage: 16 to 30 V DC Current consumption quiescent: 430 μa Current consumption: 20 ma Alarm indicator: LED red External indication: 6,8 V/5 ma Ambient temperature: C Protection class: IP 44 Colour: white Weight: 135g Dimensions with base Ø x H: 118 x 67,5 mm VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

67 7. Conventional Detectors SecuriStar Smoke detector SCD SCD 563 MC (coloured to RAL) Smoke Criteria Detector - conventional - automatic smoke alarm sensitivity through CUBUSlevelling - self monitoring of all detector parts - false alarm resistant alarm evaluation - constant sensitivity through dust compensation Available in different RAL colours Please ask for our table Overview_RALcolours_deenfresitnl.xls Operating voltage: 18 to 30 V DC Current consumption quiescent: 120 µa Current consumption: 22.5 ma Alarm indicator: LED red External indication: 6,8 V/5 ma Ambient temperature: C Protection class: IP 44 Colour: white Weight: 135g Dimensions with base Ø x H: x 67.5 mm VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

68 Temperature detector TCD Heat Class A TCD Heat Class A TCD Heat Class B Temperature Criteria Detector, preset to level and/or rateof-rise according to Class A1, A2 or B. - conventional - highly resistant to false alarm - fixed threshold and / or rate-of-rise capabilities - 100% backwards compatible to the UTD521 and UTD523 Operating voltage: 18 to 30 V DC Current consumption quiescent: 120 μa Current consumption: 20 ma Alarm indicator: LED red External indication: 6,8 V/5 ma Ambient temperature: C Protection class: IP 44 Colour: white Weight: 125g Dimensions with base Ø x H: 118 x 67,5 mm VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

69 8. Flame Detectors 8.1. Conventional Flame detector triple sensor, w/o base FDF FDF Flame detector with 3 infrared sensors and specially developed algorithms for demanding applications. Without base. - Triple-sensor infrared flame detector - Two sensors in various wavelengths ( μm and μm) - Third sensor for increased resistance to sunlight ( μm) - Microprocessor-controlled signal evaluation - Selective evaluation of flicker frequency - Excellent immunity to false alarms due to specially developed fuzzy algorithms and the latest wavelet diagnosis - Selectable application algorithms - Extremely high resistance to: electromagnetic influence, sunlight and heat radiation, humidity and corrosion - Two different sensitivity and integration stages - Large angle of vision (min. 90º) - High IP protection category (IP 67) - Large operating temperature range ( ºC) Operating voltage: 14 to 28 VDC Current consumption quiescent: 500 μa Detection angle: 90 Detection distance: 27 m with 0 viewing angle (standard) 46 m with 0 viewing angle (increased) Protection class: IP 67 Operating temperature: -35 to +70 C Rel. air humidity: 95% (without condensation) Case: aluminum Colour: white Dimensions (W x H x D) : 135 x 135 x 77 mm Weight with base: 750g VdS-Approval: G Note: The base FDFB 291 must be ordered separately See accessories for flame detectors Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

70 Flame detector DF 1101 Ex, triple sensor, w/o base DF 1101Ex DF 1101Ex - Flame detector for explosion-hazard areas zone 1 & 2 with 3 infrared sensors and special algorithms for demanding applications. Two sensors for detection in various wavelengths ( μm and μm). Third sensor for increased resistance to sunlight ( μm). Without base. - Excellent immunity to false alarms due to specially developed fuzzy algorithms and the latest wavelet diagnosis - Selectable application algorithms - Extremely high resistance to: electromagnetic influence, sunlight, heat radiation, humidity and corrosion - Two different sensitivity and integration stages - Max. 3 detectors per GTW-line allowed Operating voltage: 16 to 28 VDC Current consumption quiescent: 500 μa Detection angle: 90 Protection class: IP 67 Operating temperature: -25 to +70 C Rel. air humidity: 95% (without condensation) Colour: white Dimensions (W x H x D) : 135 x 135 x 77 mm Standard for explosion-hazard areas: EEx ib IIC T4 Approval: PTB 02 ATEX 2161 VdS-Approval: G CPD-Certificate: 0786-CPD Note: The base DFB 1190 must be ordered separately See accessories for flame detectors 70 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

71 8.2. Accessories for Flame Detectors Detector base for FDF Series FDFB 291 Base for FDF Series For indoor application, surface mounting for outdoor application, a rain hood is available Detector base for DF Series DFB 1190 Base for DF 1101 Ex For indoor application, surface mounting for outdoor application, a rain hood is available Rain Hood RH 1190 Rain hood for the infrared flame detectors for outdoor application for FDF Series and 1101 Ex. Dimension (W x H x D) 150 x 165 x 130 mm Mounting bracket MB 1190 This mounting bracket is used to fix the flame detector at the correct angle for FDF Series and 1101 Ex Ball and socket joint SJ 1190 The ball and socket joint is used to line up the flame detector with the object to be monitored for FDF Series and 1101 Ex Test lamp for DF flame detectors (also for explosion hazard areas) Stabex HF For testing of the flame detector series DF. Suitable also in explosion hazard areas Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

72 9. Conventional Ex/Atex approved Detectors Multicriteria Detector, Ex-proof, ATEX100a MMD 130 Ex-i An intrinsically safe smoke detector for use in hazardous areas of zone 1 and zone 2 and certified to classification II 2 G Ex ib IIC T4. The MMD 130 Ex-i works in accordance with the scattered light principle and detects smouldering, glowing and open fires with smoke development at an early stage Operating voltage: 10 to 28 V DC Current consumption quiescent: max. 150 μa Protection class: IP 54 Operating temperature: 20 C +70 C Dimensions with base Ø x H: x 58.1 mm Standard for explosion-hazard areas: II 2 G Ex ib IIC T4 Ex Approval: EPS 11 ATEX X VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

73 9.1. Accessories for Ex/Atex approved Detectors DC isolating converter used for "Ex-i" detectors/ 1 channel, ATEX100a GTW 01 Barrier between safe area and hazardous area for the connection of one conventional detector line. - Max 10 conventional detectors per line - For DF 1101 Ex, ORM 130 Ex-i,WDM Ex-i,WMM Ex-i - Limitation of voltage and current - Galvanic decoupling of intrinsically safe fire detectors - Mounted outside of the hazardous area Ex-zone: IIA, IIB, IIC Input voltage: 20 to 30 V DC Rated current: 0 ma to 35 ma Output voltage: min VDC / max. 21.5VDC Signal transmission: Current increase Protection class: IP 54 CW Dimensions (H x W x D): 159 x 167 x 82 mm Flammability protection cat: EEx ia DC isolating converter used for "Ex-i" detectors/ 2 channel, ATEX100a GTW 02 Same as GTW 01, except: Barrier between safe area and hazardous area for the connection of two conventional detector lines Ex-i end of line resistor 2k7 for modules MTI 8 / IM 8 or B4 EIO EOL Ex 2k7 For the termination of the alarm unit's line in connection with the SecuriLine board IM8 or EIO Ex-i end of line resistor 19k1 for module AIM EOL Ex 19k1 For the termination of the alarm unit's line in connection with the SecuriLine extended module BX-AIM Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

74 Safety barrier Z 787 EXBAR Z787 The safety barriers for intrinsically safe detector zones prevent too high an energy level from entering a hazardous area, which could cause ignition sparks if discharged there. The barrier is connected in series into the wiring of the detector zone. The device is ATEX 100a approved. Rated operational voltage: max. 28 V End-to-end resistance: 285 Ώ, max. 340 Operating current: 35 ma Total cabling length: max. 700 m Max. short circuit current: 93 ma Max. external capacity: 0,07 µf / 0,5 µf (IIC/IIB) Max. external inductance: 4 mh / 15 mh (IIC/IIB) Ambient temperature: -20 to +60 C Marking: EX II 3 G EEx n A II T4 Approval: TÜV 99 ATEX 1484 X; BAS 01 ATEX 7005 FG Safety barrier Z 787F EXBAR Z787F Identical to the Z787 safety barrier, but with replaceable fuse. The barrier is intended for use in exposed surroundings, where overvoltage, lightning strikes, voltage changes etc. could damage the ex barrier. Rated operational voltage: max. 28 V End-to-end resistance: 327 Ω, max. 363 Ω Operating current: 35 ma Total cabling length: max. 350 m Max. short circuit current: 93 ma Max. external capacity: 0,07 µf / 0,5 µf (IIC/IIB) Max. external inductance: 4 mh / 15 mh (IIC/IIB) Marking: EX II 3 G EEx n A II T4 Approval TÜV 99 ATEX 1484 X; BAS 01 ATEX 7005 Spare Parts: Description Type Art. No. G-fuse 50 ma F 5x20 G SICH Z787F FG FG Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

75 Case for safety barrier IP55/65 GEH EXB Case with a built-in 35mm fitting bracket for fitting up to 3 Z787 or Z787F safety barriers. When fitting only one safety barrier, the protective conductor terminal needed can also be fitted in the case. Shipped including three M 32 stoppers. The case contains ten M32/40 cable inlets, and the fastening bracket and two screws must be ordered separately. FG Installation type: Surface mounting Number of inlets: 10 Nominal diameter: 25 mm² Measured isolating voltage Ui: 690 V Can be sealed with leads: yes Ambient temperature: -40 to +70 C Protection class: IP 65 / IP 55 with M40 stoppers Halogen-free: no Colour: light grey (RAL 7035) plastic Dimensions (H x W x D): 200 x 160 x 98 mm Accessories: Description Type Art. No. Mounting bracket for GEH-EXB GEH EXBW FG Earth conductor terminal 10mm2 TERMINAL 10MM Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

76 10. Modernisation Detectors and Modules for SecuriFire 3000 Universal Alarm & Control Module UAC 150 The UAC 150 is a Universal Alarm and Control Module of fire detection technology. It is an addressable module which can be used both as a signal receiver for devices with switching contacts (detector) and as a control module for self-powered external devices (actuator) Multicriteria Modernisation Detector Operating voltage: V DC Current consumption quiescent: V Signal transmission: 2-wire loop addressable Dimensions (W x H x D) : 60 x 46 x 15 mm Degree of protection: IP 20 in connection with housing (GEH MOD) IP 66 Adm. ambient temperature: C VdS-Approval: G Spare Parts: Description Type Art. No. Housing for loop module IP66 GEH MOD IP66 FG MMD MMD 140 MC (coloured to RAL) The MMD 140 is an automatic detector for smoke or heat, selectable via DIL-switch. It is individual addressable and operates via the fire detector line technique 140 on the Securiton fire alarm system SecuriFire, SecuriPro and BMZ. Available in different RAL colours Please ask for our table Overview_RALcolours_deenfresitnl.xls Operating voltage: 14 to 30 V DC Operating current (normal): max. 110 μa Ambient temperature: C Protection class (incl. USB 50X): IP 44 Colour: white Dimensions with base (Ø x H) : 118,8 x 67,5 mm VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

77 Multicriteria Modernisation Detector MMD MMD 150 MC (coloured to RAL) The MMD 150 is an automatic detector for smoke or heat, selectable via DIL-switch. It is individual addressable and operates via the fire detector line technique 150 on the Securiton fire alarm system SecuriFire and BMZ. Available in different RAL colours Please ask for our table Overview_RALcolours_deenfresitnl.xls Operating voltage: 18 to 30 V DC Operating current (normal): max. 110 μa Ambient temperature: C Protection class (incl. USB 50X): IP 44 Colour: white Dimensions with base Ø x H: 118,8 x 67,5 mm VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

78 11. Bases and Accessories for SecuriStar Detectors Detector Bases USB USB (for all SecuriStar Detectors) USB (surface mounting, w/o loop contact) USB (surface mounting) USB (flush mounting) USB (surf. mount., for humid areas) USB (flush mount. In concrete) USB (Socket for mounting on pipes,) USB MC (USB 50X-6 coloured to RAL) USB MC (USB 50X-1 coloured to RAL) Base for addressable and conventional SecuriStar detectors with integrated 6 wire terminal and detector fixing by means of bayonet coupling. Available in different RAL colours Please ask for our table Overview_RALcolours_deenfresitnl.xls USB USB USB Ambient temperature: -25 C to +70 C Protection class: USB 502-1, 2, 4, 5 and 6 IP 44 USB IP 54 Colour: white Dimensions (Ø x Height above surface): USB or 6 118,5 x 25 mm USB x 50 mm USB ,5 x 50 mm USB x 92 mm USB ,5 x 70 mm Accessories: Description Type Art. No. Cover Ring extra large Ring Ø 177 mm - for USB 50x-2 or 4. Used when replacing an older detector base with cover ring bigger than the USB standard Cover Ring (extra large) - Ø 177 mm - coloured to RAL - for USB 50x-2 or 4 Ring 158 MC USB (USB with pipe clamp) 78 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

79 Detector Base, surface mounting (w/o loop cont. switch) with illuminated ring USB (surface mounting, white) Universal base with illuminated ring For addressable SecuriStar detectors with uniform 6-pin terminal block. Surface mounting, without loop contact. The detector is locked into place with a bayonet catch. Illuminated ring: - Fixed flash rate - Low power consumption - Can be actuated individually Colour: white Dimensions (Ø x H): x 25 mm Protection class: IP 44 VdS-Approval: G Ex-mounting socket for surface mounting of MMD 130 EX-I, IP 54 USB Ex-i (surface mounting, white) Along with the MMD 130 Ex-i optical- and heat detectors, it is suitable for use in Ex zones 1 and 2. It has no loop contact Colour: white Dimensions (Ø x H): x 50 mm Protection class: IP 54 VdS-Approval: G Ex-mounting socket for surface mounting of MMD 130 EX-i USB Ex-i Along with the MMD 130 Ex-i optical- and heat detectors, it is suitable for use in Ex zones 1 and 2. It has no loop contact Colour: white Dimensions (Ø x H): x 25mm VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

80 Protection basket SRS 01 (for all SecuriStar detector series and ORM130) Protective cage. To protect the detector from damage. Suitable for all SecuriStar detector series, as well for the HX detector series Dimensions (ØxH): Steel, nickel-plated 148 x 90mm Protection basket, large SRS 02 (for detectors on IP67 base or SBL 501) Protective cage. To protect the detector from damage. Suitable for SecuriStar detectors with the socket IP 54 or socket siren SBL Dimensions (ØxH): Steel, nickel-plated 148 x 122mm Detector mounting console Detector numbering plate MMK200/350 (for USB50x, w/o socket and detector) For horizontal installation of detectors on steep roofs or ceilings. Vertically adjustable in a range of 0 to 90 and expandable from 200 to 350 mm. It is ideally suited for the detector base USB 50x-xx, which is mounted by means of two size M4 screws. Sheet steel, powder-coated Colour: Light gray (RAL 7035) DNP 502 (label max. 45x75mm or P Touch label) Detector numbering plate for SecuriStar detectors FG Optional reserve terminal block for cross-connections USB Term Optional terminal block for cross-connections for SecuriStar detector base USB 50x-xx Terminal Block for Detector Base, without loop cont. switch Rubber cap for base USB 50x-1 STE 01-BK PU10 No loop switch for SecuriStar detector base USB 50x-xx (10 pcs.) GKAPPE 501 Transparent rubber cap to protect the base against moisture. Fits to USB 50x-1 or USB 50x-6 only FG Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

81 Fitting set USB MONT SET GK MM Detector heating for MCD 573 CP Kit for suspended mounting of the detector base USB 50xxx by means of spacer bolts. Provides for a better adoption to the environment temperature and reduces the probability of condensation. DBZ 1190A-AC MM KBH KL FG MM Detector dust cover for MCD, SCD or TCD Detector heating for USB 50x-xx. Needs cable binders and the respective holder (MM KBH KL). For detector MCD 573X CP only. DDC Detector Dust Cap for protection against dust during construction work. For SecuriStar detectors series 523/533, 563/573. (1000 pcs) Colour: Delivery unit: orange 1 piece Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

82 12. Room Indication Lamps Room Indication Lamp RAL 720 /RAL 720X RAL 721 RAL 722 RAL 723 RAL 728 Ex RAL 720X (IP 42) RAL 721 (IP 65) RAL 722 (IP 42) RAL 723 (IP 40) RAL 728 Ex (IP 66) RAL RHE Alarm indication of fire detectors which are not directly visible e.g. behind doors or which are mounted in a hidden place e.g. false ceiling. Activation from detector output or via appropriate output module. Ambient temperature: - 20 C to + 60 C Protection class: RAL 720X IP 42 RAL 721 IP 65 RAL 722 IP 42 RAL 723 IP 40 RAL 728 Ex IP 66 Colour: white Dimensions (D x H): RAL 720X 85 x 85 x 30 mm RAL x 70 x 53 mm RAL x 68 mm RAL ,5 x 20 x 16 mm RAL 728 Ex 80 x 93 x 92 mm Accessories: Description Type Art. No. Cover plate for RAL 722 RAL 718/ Raised floor console for RAL 722 HKS Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

83 13. Manual Call Points Addressable Manual call points SecuriLine extended Manual Call Point IP 24 / IP 67 MCP 545X-1 N (surface mounting) MCP 545X-2 N (flush mounting) MCP 545X-4 N (IP 67) MCP 545X-1AN (surface mounting, Ajax glass) MCP 545X-1SN ( surface mounting, with Swedish labeling) The manual call point MCP 545X N is a non automatic detector for fire alarm systems for direct connection to the SecuriLine / extended. An alarm is triggered directly when the glass panel is broken. The alarm persists until the glass panel is replaced with a new one. Alarm triggering is indicated by means of a red LED. For test purposes, an alarm can be triggered by means of a test key without breaking the glass panel. To increase the security with respect to false alarms, the MCP 545X N can additionally be provided with a sealable hinged cover. Operating voltage: 7-31 V DC Current consumption quiescent: 120 µa Operating temperature: - 10 to +55 C Protection class: MCP 545X-1 N, MCP 545X-1 AN and MCP 545X-2 N IP 24 MCP 545X-4 N IP 67 Colour: red, RAL 3001 Dimensions (W x H x D) : MCP 545X-1 N, MCP 545X-1 AN 89 x 93 x 61.5 mm MCP 545X-2 N 89 x 93 x 33.5 mm MCP 545X-4 N 97.5 x 93 x 73 mm VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

84 Manual Call Point IP 52 / IP 54 MCP 535X-1 (red) MCP 535X-3 (blue) MCP 535X-5 (yellow) MCP 535X-7 (Stop button, blue) MCP 535X-15 (green) Double action break glass, according to VdS and EN Delivered without inscription label and key, to be ordered separately. - for dry rooms - surface or flush mounting - key protected - integrated status LED - blue and yellow versions available Operating: 7-31 V DC Current consumption quiescent: 120 µa Operating temperature: - 20 to +50 C Protection class: MCP 535X-1, MCP 535X-3, MCP 535X-5 und MCP 535X-15 IP 52 MCP 535X-7 IP 54 Dimensions (W x H x D) : 134 x 134 x 36 mm VdS-Approval: MCP 535X-1 G MCP 535X-5 G MCP 535X-3, MCP 535X-7 G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

85 13.2. Conventional Manual Call Points Manual Call Point IP 24 / IP 67 MCP N (red, surface mounting) MCP N (red, flush mounting) MCP N (IP67) ECP 521-1EN (yellow, surface mounting) MCP 521 N Ex-i MCP N Ex-i The manual call point MCP 521 N is a non-automatic detector for fire alarm systems with current amplification line evaluation. An alarm is triggered directly by breaking the glass panel. Operating voltage: 30 V-DC Protection class: MCP N und MCP N IP 24 MCP N IP 67 Ambient temperature: -10 to +55 C Dimensions (W x H x D) : MCP N 89 x 93 x 61.5 mm MCP N 89 x 93 x 33.5 mm MCP N 97.5 x 93 x 71 mm plastic, glass fibre-reinforced CPD-Certificate: MCP N and MCP N 0832-CPD-0648 MCP N 0832-CPD-0659 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

86 Manual Call Point IP 52 / IP 54 MCP (Manual Call Points red, IP52) MCP (Manual Call Points blue, IP52) MCP (Manual Call Points yellow, IP52) MCP (Stop button blue, IP 54) MCP (Flooding green, IP52) Double action break glass, according to VdS. Delivered without inscription label and key, to be ordered separately. - for dry rooms - surface or flush mounting - key protected - integrated status LED Operating voltage: 19.6 to 30 V DC Operating current (normal): 0 ma Ambient temperature: -20 C to +50 C Dimensions (H x W x D): 135 x 135 x 37 mm VdS-Approval: MCP G MCP G MCP / MCP G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

87 13.3. Accessories for MCP Spare glass for manual call point, (MCP/ECP/FTN/FTX) CPG 845 Spare glass for MCP. MCP 545, MCP521, ECP521 Delivery unit 1 pcs. Spare glass for MCP 525-7, -14, MCP 535-7, -14, MCP 140 / 150 GLASS MCP Spare glass for MCP VdS types. MCP 525-7,-14, MCP 535-7,-14 Sealing Set for MCP 525, 535 and MCP 140/150 to be IP54 Key for MCP 520-1, and 535 X Label "Securiton" for MCP 525/535 SEALING MCP IP54 Sealing red for MCP 525 and 535 to be IP54 KEY MCP 5xx Breakable Seal for Manual Call Points Key to open the MCP. MCP 525, MCP 535 Label MCP525/535 Inlay label for the MCP 525/535, with Logo Securiton. CPS 845N Seal for locking the MCP series 521N and 545N. MCP 545-xN,MCP521-1N,ECP521-1EN Delivery unit 1 pcs. Flap, transparent, for Manual Call Point series 521 and 545 THC 845N Flap transparent, for MCP series 521N and 545N Base for MCP, surface mounting, red for MCP 521 / 545 Z FT 513 Mounting box for surface mounting, red for MCP521 and 545 series Base (plate) for MCP, flush mounting, red for MCP 521 / 545 FT513 up Fastener plate for flush mounting, red for MCP521 and 545 series Alarm resistor 680Ω for MCP 521N Ex-i and MCP N Ex-i WID 680 Alarm resistor 680Ω for MCP 521N Ex-i and MCP N Ex-i Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

88 Terminal block ST MCP For the MCP 545 and MCP 521 series Test key TK MCP For opening and testing the MCP 545 and MCP 521 series Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

89 14. Special Detectors Water sensor 12/24 VDC WS 61 A The water detector WS 61 is sensitive to smallest amounts of water. Two sensors just above the floor activate a potential free change-over contact as soon as they get in contact with water and will thus release an alarm. - Detects not only water but also other conductive liquids - Completely waterproof housing - Low current consumption - Suitable for remote testing Operating voltage: 12 to 24 V DC Operating current (normal): 10 ma Ambient temperature: -20 C to +60 C Protection class: IP 65 Dimensions (H x W x D) : 48 x 112 x 25 mm Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

90 15. Alarm Indication Modules Acoustical Alarm Medium Loop Siren IP 21 BX-SOL-R (red) BX-SOL-W (white) Loop powered and controlled sounder for SecuriLine extended. - 3 signal tones (DIN 33404, Slow Whoop and 990Hz pulsed) - Signal tone controlled from the FACP depending on the event - Configurable volume high/low Volume: 89 db / 99 db (low / high volume) Operating voltage: 12 to 30 V DC Operating current: 2.3 ma / 4.7 ma (low / high volume) Ambient temperature: -10 C to +55 C Protection class: IP 21 Dimensions (D x H) : 108 x 96 mm ABS VdS-Approval: G Siren BSE 128 (surface mounting) BSE 128 (flush mounting) 24V BSE 128 red (surface mounting, IP54) BSE 128 white (surface mounting, IP54) BSE 128 red (surface mounting, IP65) BSE 128 white (surface mounting, IP65) BSE 128 UP (flush mounting, only available in white) Acoustical alarm device for fire alarm systems. Robust, reliable construction, high protection class, low power consumption signal tones - 2 nd tone can be activated via separate input - IP 54, flat profile socket - Red and white type available Volume (DIN tone): up to 115dB (98dB) in 1 m distance Operating voltage: 24 V DC Operating current: max. 27 ma Ambient temperature: -40 C to +80 C Protection class: IP 54 or IP65 Dimensions: 101 x 81 mm Regulation compliance: EN Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

91 Sounder Base USB 50x on the Loop BX-SBL 501-W (white) BX-SBL 501-WDB (deep base, white) BX-SBL 501 BX-SBL 501 Loop ceiling siren Acoustic alarm unit, to be mounted between the detector socket USB 50x and the ceiling or on the wall, for use in a SecuriFire fire alarm system. Connects directly to SecuriLine extended via 2 wire without any further power supply line. The deep base version (DB) is for a side wise cable installation. - 3 signal tones (DIN 33404, Slow Whoop and 880Hz pulsed) - Signal tone controlled from the FACP depending on the event - Configurable volume high/low Volume: 80 db / 90 db(a) (low / high volume) Operating voltage: 15 to 30 V DC Operating current: 1.3 ma / 3.9 ma (low / high volume) Ambient temperature: -10 C to +55 C Protection class: IP 31d Dimensions (D x H): 117 x 41 mm Version DB: 117 x 45 mm PC/ABS Colour: white RAL 9003 BX-SBL 502-W (white) BX-SBL 502-WDB (deep base, white) BX-SBL 502-RDB (deep base, red) Acoustic alarm unit, to be mounted directly on the ceiling or on the wall. Connects directly to SecuriLine extended via 2 wire without any further power supply line. The deep base version (DB) is for a side wise cable installation. - 3 signal tones (DIN 33404, Slow Whoop and 880Hz pulsed) - Signal tone controlled from the FACP depending on the event - Configurable volume high/low Volume: 80 db / 90 db(a) (low / high volume) Operating voltage: 15 to 30 V DC Operating current: 1.3 ma / 3.9 ma (low / high volume) Ambient temperature: -10 C to +55 C Protection class: IP 31d Dimensions (Ø x H): 114 x 32 mm Version DB: 114 x 36 mm PC/ABS VdS-Approval G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

92 15.2. Optical Alarm Medium Beacon wall mounted BW ESDA1000RRS (lens red, socket red, small) BW ESDA1000RRD (lens red, socket red, deep IP65) BW ESBA4000WWS (lens clear, socket white, small) BW ESBA4000WWD (lens clear, socket white, deep IP65) The beacon visually signals an alarm according EN Two flash sequences can be set. The housing is made of plastic. The Beacons can be connected to SecuriFire via B3/B5-OM8, B4/B6-EIO, and BX-IOM. Operating voltage: 17 to 60V DC Power consumption typically 24 0,5 Hz 20 1 Hz 40mA Switch on current: 720 ma for 3,6 µs Flashing frequency: 0,5 or 1 Hz Ambient temperature: -25 C to +70 C Protection class: Flat base IP21C Deep base IP65 Dimensions (Ø x H): Flat base 100 x 100 mm Deep base 100 x 122 mm Weight: Flat base 170 g Deep base 220 g VdS-Approval: ESDA G ESBA G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

93 Beacon ceiling mounted BC ESDA2000RRS (lens red, socket red, small) BC ESDA2000RRD (lens red, socket red, deep IP65) BC ESBA3000WWS (lens clear, socket white, small) BC ESBA3000WWD (lens clear, socket white, deep IP65) The beacon visually signals an alarm according EN Two flash sequences can be set. The housing is made of plastic. The Beacons can be connected to SecuriFire via B3/B5-OM8, B4/B6-EIO, and BX-IOM. Operating voltage: 17 to 60V DC Power consumption typically 24 0,5 Hz 20 1 Hz 40mA Switch on current: 650 ma for 3,6 µs Flashing frequency: 0,5 or 1 Hz Ambient temperature: -25 C to +70 C Protection class: Flat base IP21C Deep base IP65 Dimensions (Ø x H): Flat base 100 x 94 mm Deep base 100 x 117 mm Weight: Flat base 170 g Deep base 220 g VdS-Approval: ESDA G ESBA G Loop flashlight BX-FOL-RR (red base, red) BX-FOL-WR (white base, white) BX-FOL-RO (red base, orange) BX-FOL-WO (white base, orange) Powered and driven by the loop. 2 flash frequencies (fast/slow), connectable to SecuriLine extended. Operating voltage: 12 to 30 V DC Operating current: 6.5 ma Ambient temperature: -10 C to +55 C Protection class: IP 21 Dimensions (H x W x D) : 93 x 93 x 54 mm ABS VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

94 Flash Light 24V Solex R/SR/10C (lens red, base red) Solex A/SW/10C (lens amber, base white) Solex G/SW/10C (lens green, base white) Solex B/SW/10C (lens blue, base white) Solex CL/SW/10C (lens clear, base white) Optical xenon alarm medium in a robust design for indoor and outdoor application, available in 5 different lens colours. The red lens comes with red base only, other colours with white base only. Operating voltage: 9 to 60 V DC Operating current: ma Switch on current: 40.5mA for 4ms Light intensity: red/amber, green, blue and clear 4.8/8.4/7/2.8/14 cd Flash frequency: 1 Hz Protection class (with special socket): IP 54 (65) Operation temperature: -25 C +70 C Dimensions (D x H): 93 x 63 mm Housing: ABS / Polycarbonate VdS-Approval: G Accessories: Description Type Art. Nr. Socket deep, red, IP 65 SO/D/R Socket deep, white, IP 65 SO/D/W Socket deep, red, IP 65, 230V SO/D/R/ Socket deep, white, IP 65, 230V SO/D/W/ Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

95 15.3. Combined Siren /Beacon Combined Siren/Beacon wall mounted SBW ESFA1000RRS ( lens red, socket red, small) SBW ESFA1000RRD ( lens red, socket red, deep IP65) SBW ESCA4000WWS ( lens clear, socket white, small) SBW ESCA4000WWD ( lens clear, socket white, deep IP65) The audible/optical signal transmitter is compliant with EN and serves to signal a fire alarm audibly and optically in buildings; with an additional IP65 base it can also be used outdoors. The signal transmitter can be mounted on the wall (category W) Operating voltage: 17 to 60 V DC Power consumption typically Hz 25 1 Hz 45 ma Switch on current: 520 ma for 3.6 μs Flash frequency: 0.5 or 1 Hz Protection class Flat base (Deep base): IP21C (IP65) Operation temperature: -10 C +70 C Dimensions (D x H): Flat base 100x100 mm Deep base 100x122 mm Weight Flat base 220 g Deep base 270 g Housing: Polycarbonate VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

96 Combined Siren/Beacon ceiling mounted SBC ESFA2000RRS (lens red, socket red, small) SBC ESFA2000RRD (lens red, socket red, deep IP65) SBC ESCA3000WWS (lens clear, socket white, small) SBC ESCA3000WWD (lens clear, socket white, deep IP65) The audible/optical signal transmitter is compliant with EN and serves to signal a fire alarm audibly and optically in buildings; with an additional IP65 base it can also be used outdoors. The signal transmitter can be mounted on the ceiling (category C). Operating voltage: 17 to 60 V DC Power consumption typically Hz 25 1 Hz 45 ma Switch on current: 510 ma for 3.6 μs Flash frequency: 0.5 or 1 Hz Protection class Flat base (Deep base): IP21C (IP65) Operation temperature: -10 C +70 C Dimensions (D x H): Flat base 100x95 mm Deep base 100x117 mm Weight Flat base 220 g Deep base 270 g Housing: Polycarbonate VdS-Approval: G Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

97 16. Radio Detectors Wireless Detector DOW 1171 Wireless smoke detector operating in the new MHz SRD (Short Range Devices) band, released exclusively for security technology. The SRD band does not interfere with long-range industrial, scientific and medical applications with high transmission power. Up to 30 radio-linked smoke detectors can communicate with a single wireless module. Key features are: - Highly efficient installation, easy expandable - High operational reliability - Outstanding interference immunity Requires a radio base unit BX-RGW equipped with the radio interface BA-RFM to communicate with the fire alarm panel. Operating voltage: 2 Stk. 9V- lithium batteries Average current consumption: 68 µa Battery operating life: > 5 years in normal use Frequency range: 868 to 870 MHz (SRD band) Channel spacing: 25 khz Transmission strength: max. 5 mw Range in buildings: up to 40 m where there is indivisibility Aerials: double integrated aerials Protection class: IP 44 Ambient temperature: -10 to +55 C Rel. air humidity: max. 95% at 34 C Dimensions (D x H): 119 x 73 mm Case material: PC / ABS plastic Colour: white, similar to RAL 9010 Weight: 195 g Radio approval: CE 0123 VdS-Approval G FG Accessories: Description Type Art. Nr. Detector Base for Wireless Detector Battery for Wireless Detector (2 pcs. per detector needed) DBW 1171 U9VL-J-P FG FG Note: Detector base and two 9V batteries must be ordered separately. Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

98 Wireless Manual Call Point Note: Labeled in German Language only! SMF 6120 For manually triggering a fire alarm in areas, where architectural aspects or particular operating processes mean that cables can only be laid with difficulty, or not at all. The alarm is triggered by smashing the glass panel and pressing the button. The detector communicates bidirectionally with the BX-RGW radio gateway over the MHz. Short Range Device frequency band. Power is supplied by 2 batteries (not supplied). Requires a radio base unit BX-RGW equipped with the radio interface BA-RFM to communicate with the fire alarm panel. Power supply: 2 Stk. 3,6V-lithium batteries Average current consumption: 60 µa Battery life: at least 5 years in normal use Frequency range: MHz (SRD) Frequency selection: 16 groups with 5 channels Channel spacing: 25 khz Transmission strength: max. 5 mw Range in buildings: up to 40 m where there is intervisibility Aerials: double integrated aerials Protection class: IP 43 Ambient temperature: -10 to +55 C Rel. air humidity: 95%, without condensation Dimensions: 125 x 125 x 57 mm (HxWxD) Case material: ABS Colour: red RAL 3000 Weight: 350 g Radio approval: CE 0123 Accessories Description Type Art. No. Socket for Wireless Manual Call Point Lithium Battery Wireless Manual Call Point Spareglass for Wireless Manual Call Point SMF 6120 BASE SMF 6120 BATT SMF 6120 GLAS FG FG FG FG Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

99 17. Overvoltage Protection Devices Lightning/Overvoltage arrester combination type 1+2 FLT-SEC-T1+T2-1S-350/25-FM Plug-in lightning and overvoltage arrester combination, in accordance with Type 1+2/Class I+II, for 1-phase power supply networks, with separate N and PE (L1, PE, N) Nominal voltage: 240 V AC Total surge current (8/20) μs: 25 ka Protection class: IP 20 Ambient temperature: -40 C C Case material: PBT-FR Dimensions (H x W x L): 95,2 x 71,2 x 74,5 mm Type 3 overvoltage protection device PLT-T3-IT-230-FM Overvoltage protection type 3, as device protection for termination devices in IT systems, error indication and remote indicator contact Nominal voltage: 230 V AC Surge voltage category: III Pollution degree: 2 Protection class: IP20 Ambient temperature: -40 C C Case material: PA 6.6 Dimensions (H x W x L): 90 x 17,7 x 65,5 mm Ovevoltage protection device PT-IQ-4x1+F-24DC-PT Overvoltage protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for four signal wires with common reference potential. Indirect grounding via gas-filled surge arrester Operating voltage: 24 V DC Protection class: IP20 Ambient temperature: -40 C C Case material: PA 6.6 Dimensions (H x W x L): 109,3 x 17,7 x 77,5 mm Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

100 Overvoltage protection device PT-IQ-2x1+F-24DC-PT Overvoltage protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for two signal wires with common reference potential. Indirect grounding via gas-filled surge arrester Operating voltage: 24 V DC Protection class: IP20 Ambient temperature: -40 C C Case material: PA 6.6 Dimensions (H x W x L): 109,3 x 17,7 x 77,5 mm Overvoltage protection device PT-IQ-5-HF+F-5DC-PT Overvoltage protection, consisting of protective plug and base element, with integrated multi-stage status indicator on the module for five signal wires. For HF applications and telecommunications interfaces without supply voltage (up to 90 Mbps) Operating voltage: 5 V DC Protection class: IP20 Ambient temperature: -40 C C Case material: PA 6.6 Dimensions (H x W x L): 109,3 x 17,7 x 77,5 mm Overvoltage protection controller PT-IQ-PTB-PT Controller for power supply and multi-stage, floating remote signaling of connected overvoltage protection modules Operating voltage: 30 V AC / 50 V DC Protection class: IP20 Ambient temperature: -40 C C Case material: PA 6.6 Dimensions (H x W x L): 109,3 x 17,7 x 77,5 mm 100 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

101 Overvoltage protection device TT-SLKK5-F/110AC Modular terminal block with gas-filled overvoltage arrester as coarse protection between clamping connector and DIN rail, separate PE connection, nominal voltage: 110 V AC, mounting on NS 35/7.5, terminal width: 6.2 mm, terminal height: 69 mm Nominal voltage UN: 110 V AC / 150 V DC Protection class: IP 20 Ambient temperature: -40 C C Case material: PA Dimensions (H x W x L): 66,5 x 6,2 x 69,5 mm Overvoltage Accessoires Accessories: Description Type Art. Nr. Shield clamps for cable diameter 3-6 mm SSA Shield clamps for cable diameter 5-10 mm SSA Feed-through terminal block, 4 pieces STU 10/4x2,5 4er Housing with DIN rail and transparent cover GEH HS TP Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

102 18. Batteries Backup Battery 12V / 2.2 Ah Battery 2.3 Ah Battery, Pb, 12V, VdS approved Dimensions (H x W x D): Weight : Capacity: 69 x 36 x 180 mm 1kg 2.3 Ah Backup Battery 12V / Ah Battery 7 Ah Battery, Pb, 12V, VdS approved Dimensions (H x W x D): Weight: Capacity: 153 x 67 x 102 mm 2.2kg 7 Ah Backup Battery 12V / Ah Battery 12 Ah Battery, Pb, 12V, VdS approved Dimensions (H x W x D): Weight: Capacity: 153 x 92 x 102 mm 4kg 12 Ah Backup Battery 12V / Ah Battery 18 Ah Battery, Pb, 12V, VdS approved Dimensions (H x W x D) : Weight: Capacity: 183 x 78 x 169 mm 6kg 18 Ah Backup Battery 12V / Ah Battery 26 Ah Battery, Pb, 12V, VdS approved Dimensions (H x W x D): Weight: Capacity: 168 x 177 x 127 mm 8.2kg 26 Ah 102 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

103 Backup Battery 12V / Ah Battery 45 Ah Battery, Pb, 12V, VdS approved Dimensions (H x W x D): Weight: Capacity: 199 x 167 x 172 mm 17kg 45 Ah Backup Battery 12V / 65 Ah Battery 65 Ah Battery, Pb, 12V, VdS approved Dimensions (H x W x D): Weight: Capacity: 392 x 168 x 176 mm 20kg 65 Ah Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

104 19. Installation, Test and Commissioning Tools Detector Test Equipment Univ. Detector Remover, standard ver. (for detector series 523/533/563/573) UDR 533 S Removal and insertion of SecuriStar detector series 523/533 and 563/ solid version - Pluggable on telescopic pole series UTP Univ. Detector Remover, cardan vers. (for detector series 523/533/563/573) UDR 533 K Removal and insertion of SecuriStar detector series 523/533 and 563/ With cardan joint - Pluggable on telescopic pole series UTP Adapter for UDR 521/531 K (for detector series 523/533/563/573) UDR 533 A The UDR 533 A serves as exchangeable adaptor and can be inserted into the UDR 521/531 K, detector removers for SecuriStar detector series, 523/533, 563/ Univ. replacement dev. for det. series STD, SSD, UTD 5x1 with gum links UDR 521/531 The UDR 521/ 531 serves as exchangeable adaptor and can be inserted into the UDR 521/531 K, detector removers for SecuriStar detector series STD, SSD, UTD 5x1 with gum links Univ. replacement dev. for det. series STD, SSD, UTD 5x1 with cardan. m. UDR 521/531 K The UDR 521/ 531 serves as exchangeable adaptor and can be inserted into the UDR 521/531 K, detector removers for SecuriStar detector series STD, SSD, UTD 5x1 with cardanic mounting Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

105 Fire Detector Test Equipment 533 CO test extension for FDT 533 FDT 533 Fire Detector Test equipment. For SecuriStar detector series 523/533, 563/573 (smoke and heat) and for the SecuriStar detector series 521/531 (only smoke). - Pluggable on telescopic pole series UTP - For using with 918/5 test gas can FDT 533 CO-Set For the optional enhancement of the FDT 533 for testing the CO functionality of the multiple sensor detector CCD573X. - Pluggable on FDT For using with CO test gas can Adapter SOLO-Testpole to UDR 533 ASU 533 Adapter Solo test pole to UDR Universal Telescope pole (1.7m - 3m) UTP 6 Pole for various detector removal and test devices extendable from: 1.7 to 3.0 m Universal Telescope pole (2.2m - 4m) UTP 7 Pole for various detector removal and test devices extendable from: 2.2 to 4.0 m Extension (1.34m) for Univ. Telescope pole UTP 6/7 UTP 5 Extension piece 1.35 m for the telescopic pole types UTP 6 and UTP Working height up to: 6.0 m / 7,00 m Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

106 Test gas 918/5 test gas can Attention: Dangerous Good For functional testing of smoke detectors. Lasts for approx. 200 tests. Free of halogenated hydrocarbons CO Test gas SOLO C3 Attention: Dangerous Good For functional testing of Co detectors. Carbon monoxide is a highly toxic, colourless and odourless gas Smoke and Heat Det. Test Kit (incl. 2 battery batons and fast charger) Testifire 1001 Fire Detector Test equipment for SecuriStar detector series 521/531, 523/533, 563/573, smoke detectors, heat detectors and combined detectors (smoke and heat) as well for the HX detector series. - Creates smoke and heat from the same unit - Integrated ventilator for rapid air cleaning inside the tester - Activation via infrared sensor, no mechanical contact necessary - Multilanguage user menu on the display - Battery powered, free movable device Complete set including - Test device smoke and heat - two battery batons - battery charger Smoke, Heat and CO Det. Test Kit (incl. 2 batt. batons and fast charger) Smoke Capsule Testifire 2001 Same as Testifire 1001, except: Including carbon monoxide release for testing of COdetectors (for Testifire) Smoke Capsule TS3 For Testifire 1001 and 2001 tester CO Capsule (for Testifire) CO Capsule TC3 For Testifire 2001 tester Battery Baton (for Testifire) Solo 720 For Testifire 1001 and 2001 tester Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

107 Universal Fast Battery Charger (for Testifire) Solo 726 For Testifire 1001 and 2001 tester. Universal fast battery charger Protective Carrying / Storage Bag (for Testifire) Solo 610 Bag for tester and access poles Pole Carrying / Storage Bag (for access poles) Solo 620 Separate Pole Carrying / Storage Bag for access poles Fibreglass 4 Section Telescopic Pole metres Solo 100 Fibreglass 2 Section Telescopic Pole metres Fibreglass 4 section telescopic pole - Extends from 1.26m to 4.5m - Enables access to detectors fitted up to 6m - Accepts three Solo 101 to reach 9m Solo 108 Fibreglass Extension Pole - 1,13 metres Fibreglass 2 section telescopic pole - Extends from 1.26m to 2.5m - Enables access to detectors fitted up to 4m - Accepts additional Solo 101 s for greater heights Solo 101 Fibreglass single section pole - Extends from 1.13m - Enables access to detectors fitted up to 2.5m - Connects to Solo 100, Solo 108 or additional Solo 101s for greater heights Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

108 19.2. Loop Test Equipment Loop Test Board (incl. AC/DC adapter) STB 01X-E Hand held control device for testing and trouble shooting of the SecuriLine extended installation and their participants. Includes the power supply adapter ( VAC/24VDC) and an USB serial interface to a PC. Suitable for SecuriLine extended up to 250 loop devices. Accessories Description Type Art. No. STB 01X Transport case STB 01X Transport case Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

109 20. Product Type Index Ex-i /5 test gas A ADAM AFS ASS ASU B B3 KAB PSU B3 PPR B3 SERVST B3 UIO KAB B3 UIO KAB B3-BGT B3-BSR B3-DCI B3-IM B3-LEE B3-LEE B3-MMI-EAT64 BFE B3-MMI-EAT B3-MMI-IPEL BFE B3-MMI-IPEL B3-MMI-IPES BFE B3-MMI-UIO B3-REL B3-REL B3-REL16E B3-STS-IPEL B3-STS-MMI-EAT B3-USI B4 SERVBR B4-EIP B4-USI B5 BAF B5 BATKAB B5 BATKAB B5 BFP B5 EPI FPC-E B5 EPI FPC-GS B5-ADB B5-AE Cat7-RJ B5-BUS B5-DXI B5-EPI-FPCZ B5-EPI-FPS-S B5-EPI-PCM-GS B5-EPI-PIM-GS B5-HS 35/ B5-LAN B5-MCB B5-MCB15A B5-MIC B5-MIC B5-MIC-PPE B5-MMI-FIP B5-MMI-FPCZ B5-MMI-FPS-S B5-MMI-IPS-S B5-MRI B5-NET B5-NET2-FXM B5-NET2-FXS B5-NET B5-OM B5-PDR-CO B5-PDR-DW B5-PIE-A B5-PIF B5-PSU B5-SCP B5-SCP3010A B5-SCP B5-SCP3020A B5-SCP B5-SCP3030A B5-SCP B5-SCP3040A B5-SCP B5-SCP3050A B5-STS-AF B5-STS-BFP B5-STS-BFP B5-STS-BGT-SF B5-STS-KL B5-STS-MIC B5-STS-MIC B5-STS-MMI B5-STS-MMI-SUB B5-STS-PR B5-UGKA-SF B6 BATKAB B6-ADB B6-AS Cat7-RJ B6-BCB B6-BCB B6-EIO B6-LAN B6-LXI B6-MIC B6-MIC B6-NET B6-NET2-FXM B6-NET2-FXS B6-PSU B6-SCP B6-SCP1020A B6-SCP B6-SCP2010A B6-SCP B6-SCP2020A B6-SCP B6-SCP2030A B6-SCP B6-SCP2040A B6-SCP B6-SCP2050A B7-CPB B7-PLB-PCM B7-SCP B8-BAF B8-NET B8-NET2-FX B8-NET B8-NET-FX B8-STS-BGT-SF B8-SXI B9-NET-FX BATT FM Battery 12 Ah Battery 18 Ah Battery 2.3 Ah Battery 26 Ah Battery 45 Ah Battery 65 Ah Battery 7 Ah Battery U9 VL-J BC ESBA3000WWD BC ESBA3000WWS BC ESDA2000RRD BC ESDA2000RRS BSE 128 red BSE 128 UP BSE 128 white BW ESBA4000WWD BW ESBA4000WWS BW ESDA1000RRD BW ESDA1000RRS BX-AIM BX-ESL BX-FOL RO BX-FOL WO BX-FOL-RR BX-FOL-WR BX-I BX-IM BX-IOM BX-MDH BX-MDI BX-O BX-O2I BX-OI BX-REL BX-RGW BX-SBL 501-W BX-SBL 501-WDB BX-SBL 502-DBR BX-SBL 502-W Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

110 BX-SBL 502-WDB BX-SCU BX-SOL-R BX-SOL-W C Cat5-Kabel 0,5 m Cat5-Kabel 3 m CCD 573X CCD 573X MC CO Capsule TC COS CPG CPS 845N D D&L MIC Sim D&L Studio DBW DBZ 1190A-AC DDC DF 1101Ex DFB DFC DKM SCHL DNP DOM-key DOW E ECP 521-1EN EHB EOL Ex 19k , 73 EOL Ex 2k EXBAR Z EXBAR Z787F F FDF FDFB FDT FDT 533 CO-Set FFM FFM FFM FLT-SEC-T1+T2-1S-350/25- FM FMC FMC FMC FME FME FME FT513 up G GEH EXB GEH EXBW GEH HS TP GEH MOD IP GEH MOD2 IP GEH MOD3 IP GKAPPE GLASS MCP GTW GTW H HKS K KEY MCP 5xx L Label MCP525/ LIC MIC Lang LIC RA LIC Studio LKM 593X LKM-Set M MCD 573X CP MCD 573X MC MCD 573X-S MC MCD 573X-SP MCD 573X-SP MC MCD573X MCD573X-S MCP 521 4N MCP 521-1N MCP 521-2N MCP 521-4N Ex-i MCP 521N Ex-i MCP MCP MCP MCP MCP MCP 535X MCP 535X MCP 535X MCP 535X MCP 535X MCP 545X-1 N MCP 545X-1AN MCP 545X-1SN MCP 545X-2 N MCP 545X-4 N MM ANB M MM ANB M MM ANB M MM GM M MM GM M MM GM M MM GM M MM KBH KL MM RR M20 - M MM RR M25 - M MM SN M MMD 130 Ex-i MMD MMD 140 MC MMD MMD 150 MC MMK200/ MONT SET GK MP MOD GR MP MOD GR MP MOD KL P PD FRB... 15, 25 PD PPR PLB PLB PLT-T3-IT-230-FM PT HKT-5-HF+F-5DC PT-IQ-2x1+F-24DC-PT PT-IQ-4x1+F-24DC-PT PT-IQ-PTB-PT R RAL 718/ RAL 720X RAL RAL RAL RAL 728 Ex RAL RHE Ring 158 MC Ring S SBC ESCA3000WWD SBC ESCA3000WWS SBC ESFA2000RRD SBC ESFA2000RRS SBW ESCA4000WWD SBW ESCA4000WWS SBW ESFA1000RRD SBW ESFA1000RRS SCD SCD SD-CARD for B5/B SDI 81X/ SDI 82X SEALING MCP IP SF 500 DCU SJ SMF SMF 6120 BASE SMF 6120 BATT SMF 6120 GLAS Smoke Capsule TS SO/D/R SO/D/R/ SO/D/W SO/D/W/ Solex A/SW/10C Solex B/SW/10C Solex CL/SW/10C Solex G/SW/10C Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

111 Solex R/SR/10C Solo Solo Solo Solo Solo Solo Solo SOLO C SPU SRS SRS SSA SSA ST MCP Stabex HF STB 01X Transport case STB 01X-E ST-B ST-BAF-MMI-L ST-BAF-OM ST-DCI STE 01-BK PU ST-EIOX ST-FBD ST-LOOP/DAI ST-LPI/USI4/HFI ST-MTI ST-OM ST-OM ST-PSU ST-REL ST-SET REL ST-SET REL STU 10/4x2,5 4er ST-USI T TCD TCD TCD TCD TCD TCD TERMINAL 10MM Testifire Testifire THC 845N TK MCP TT-SLKK5-F/110AC U U9VL-J-P UAC UDR 521/ UDR 521/531 K UDR 533 A UDR 533 K UDR 533 S UIO GEH UIO KAB UIO KAB UIO STP... 21, 45 UIO-GEH USB USB MC USB USB USB USB USB USB MC USB Ex-i USB Term USB UTP UTP UTP W WID Z Z FT Z787F SI ZUB SICH ZUB SICH Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

112 112 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/3000

113 Securiton Product Catalogue 2016 SecuriFire 500/1000/2000/

114 SecuriRAS ASD 531/532/535 Product Catalogue 2016

115 Content 1. Aspirating Systems ASD Base Units Smoke Sensors (SSD) Expansion modules Demo and Test Equipment Engineering and Configuration Tools Tubes and Fittings for Sampling Pipe PVC Tubes and Fittings ABS Tubes and Fittings Flex Pipe Materials Concrete Inserts Copper Tube Materials Stainless Steel Tube Materials Special Tubing Parts Sampling Points Clamps, Glue and Cleaner Accessories Spare Parts Product Type Index Securiton Product Catalogue 2016 ASD 531/532/535

116 Introduction Aspirating smoke detection systems need little introduction these days: They are deployed extensively and account for more than 10% of the fire detection market in Europe. Aside from this commercial success, the aspirating technology has become the subject of the European product standard EN This standard, in conjunction with the latest Code of Practice, will help to ensure that the reliable performance and good reputation of the technique is not eroded by unapproved and inappropriate products. It is strongly recommended that the system designer becomes familiar with these standards and codes. EN EN has introduced a fire sensitivity classification system incorporating classes A, B and C. These classes assign the sensitivity at the sampling points to typical applications: Normal Sensitivity: The same sensitivity as normal optical point detectors (2% - 5% obsc. / m) Enhanced Sensitivity: Responding to smoke at concentrations between 0.8% and 2% obsc. / m. High Sensitivity: responding to smoke at concentrations of less than 0.8% obscuration /m. It is important to define appropriate requirements / expectations for an aspirating smoke detection system at the earliest possible stage for assuring proper system engineering. Code of Practice When designing an air sampling system, considerations must be given to the requirements of relevant local Codes of Practice, Standards and Regulations that are used to govern the design of detection systems. What the designer must bear in mind is that these documents may only deal with the minimum acceptable requirements, often related to the performance of conventional point detectors. High sensitivity smoke detection systems such as the ASD 535 can offer performance far in advance of traditional detection elements and various bodies such as the Fire Industry Association (FIA) have documented the related engineering requirements in their Code of Practice for Design, Installation, Commissioning & Maintenance of Aspirating Smoke Detector (ASD) Systems PipeFlow - Engineering Support at your Fingertips Designing complex piping systems according to EN and in line with the local Code can be challenging. Systems may easily become asymmetrical and you may require engineering tools for proper dimensioning and placing of sampling points. We have created the industry s first and only software tool using physical airflow modelling for precise engineering of flow balanced aspirating systems. In plus, PipeFlow lets you draw your system in 3D and delivers you all documents needed for hassle-free installation, testing and commissioning. Securiton Product Catalogue 2016 ASD 531/532/535 3

117 How to read this catalogue Example of a typical entry for an item Type & Article Number Please quote this number when making an enquiry or ordering Memory Card Module MCM 35 This Memory Card Module lets you trace up to events and logs the measurement data of 80 days. This capability is fixed (SD cards larger than 1GB will not expand it). The board comes with mounting brackets, screws and ribbon cables, but without SD card Operating Voltage from AMB 35: Dimensions (H x W x D) : Weight: Documentation: 5 V DC 95x58x17mm 43 g T Illustration Description and technical data 4 Securiton Product Catalogue 2016 ASD 531/532/535

118 1. Aspirating Systems 1.1. ASD Base Units Aspirating Smoke Detector (including SSD 31) ASD 531 The SecuriRAS ASD 531 aspirating smoke detector is designed for smaller monitoring areas and for the easiest possible handling. The ASD 531 is equipped with a highly sensitive smoke sensor SSD 31 using a single sampling pipe network. The housing provides the option for two expansion modules. Commissioning and configuration is done directly on the device without any software tool. For planning the ASD PipeFlow software allows an optimized design of any installation Aspirating Smoke Detector Mains voltage: 14 to 30 V DC Ambient temperature: -10 C to + 55 C Protection class: IP 54 Dimensions (H x W x D) : 195 x 290 x 140 mm Case cover material: ABS-Blend, UL 94-V0 Case Colour: grey/anthracite Weight: 1,95 kg Standards: EN Class A, B and C, EN UL 268, FM 3230 ASD 532 The SecuriRAS ASD 532 aspirating smoke detector is designed for small to midsize monitoring areas. The ASD 532 base unit is provided for a highly sensitive smoke sensor SSD 532 (to be ordered separately) for a single sampling pipe network. The measured smoke level is indicated on a bar graph display. The housing provides the option for two expansion modules. Commissioning and configuration is done either directly on the device or via the ASD Config software tool. For planning the ASD PipeFlow software allows an optimized design of any installation. Mains voltage: 14 to 30 V DC Ambient temperature: -20 C to + 60 C Protection class: IP 54 Dimensions (H x W x D) : 195 x 290 x 140 mm Case cover material: ABS-Blend, UL 94-V0 Case Colour: grey/anthracite Weight: 1,7 kg Standards : EN Class A, B and C, EN Securiton Product Catalogue 2016 ASD 531/532/535 5

119 Aspirating Smoke Detector ASD ASD Sampling pipe / Detector ASD Sampling pipes / Detectors ASD ASD Sampling pipe / Detector, 1 Smoke level display 2 Sampling pipes / Detectors, 2 Smoke level displays The SecuriRAS ASD 535 aspirating smoke detector is designed for universal applications mainly for midsize to large monitoring areas. The ASD 535 base units provide space for 1 or 2 highly sensitive smoke sensors SSD 535 (to be ordered separately) for 1 or 2 sampling pipe networks The measured smoke level can be indicated on a bar graph display (models -3 and -4). The housing provides the option for four expansion modules. Commissioning and configuration is done either directly on the device orvia the ASD Config software tool. For planning the ASD PipeFlow software allows an optimized deisgn of any installation. ASD Mains voltage: 10.5 to 30 V DC Ambient temperature: -30 C to + 60 C Protection class: IP 54 Dimensions (H x W x D) : 397 x 265 x 148 mm Case cover material: ABS-Blend, UL 94-V0 Case Colour: grey/anthracite Weight: 3,85 kg Standards: EN Class A, B and C VdS-Approval: G ASD ASD Securiton Product Catalogue 2016 ASD 531/532/535

120 1.2. Smoke Sensors (SSD) Smoke Sensor for ASD 531 Smoke Sensor for ASD 532 Smoke Sensor for ASD 535 SSD 31 Alarm Sensitivity range 0,02% 10% /m The smoke sensor SSD 31 is pre-installed in the ASD 531 and is also available as replacement part. 3 Pre-signals are set on a fixed percentage of the alarm threshold (30/50/70%). Sensitivity range alarm: 0.02 %/m 10 %/m Sensitivity range pre-signals: %/m 7 %/m Ambient temperature: -10 C to + 55 C Dimensions (H x W x D): 120 x 116 x 95 mm SSD Alarm Sensitivity range 0.02% 10% /m The smoke sensor SSD 532 has to be ordered separately for the ASD Pre-signals can be set between 10 and 90% of the alarm threshold. Sensitivity range alarm: 0.02 %/m 10 %/m Sensitivity range pre-signals: %/m 9 %/m Ambient temperature: -20 C to + 60 C Dimensions (H x W x D): 120 x 116 x 95 mm SSD Alarm Sensitivity range % /m The smoke sensor SSD 535 has to be ordered separately for the ASD 535. Pre-signals can be set between 10 and 90% of the alarm threshold. Sensitivity alarm: 0.02 %/m 10 %/m Sensitivity range pre-signals: %/m 9 %/m Ambient temperature: -30 C to + 60 C Dimensions (H x W x D): 120 x 136 x 95 mm Fastener plate to cover a smoke sensor chamber ASD 535 Verschl The fastener plate is for closing the 2nd channel when it is temporarily not used. (e.g. Conversion of a room) The packaging unit of the fastener plate is 50 pieces. Securiton Product Catalogue 2016 ASD 531/532/535 7

121 1.3. Expansion modules Loop I/F module for Special Fire Detectors XLM 35 SecuriLine extended With the installation of an XLM 35, special fire detectors like ASDs can be ideally connected via the addressable loop to the SecuriFire fire alarm systems. The normative alarm transmission to the superordinate FACP is then accomplished via the XLM 35.. The XLM 35 module allows also central configuration of special fire detectors with the Config Over Line function. The module comes with mounting brackets, screws and ribbon cable Dimensions (H x W x D): Weight: 95 x 58 x 17 mm 56 g Loop I/F module for ASD 535 SLM 35 SecuriLine standard This loop interface brings faults and alarms to your fire alarm panel and lets you reset the ASD 535 by the panel. Note: ASD configuration is done via USB using ASD config software and a PC. The module comes with mounting brackets, screws and ribbon cable Dimensions (H x W x D) : Weight: 95x58x17 mm 56 g Relay I/F module for ASD 535 RIM 35 5 relays with changeover contacts The RIM 35 brings five (5) additional relay outputs to your ASD 535. Expansion limit is two (2) RIM 35 / 10 relays. Each relay can be assigned to any ASD event by programming with the ASD Config software. The module comes with mounting brackets, screws and ribbon cable Max. relay output load: Dimensions H x W x D) : Weight: 50 / 1 / 30 V DC/A/W 95x58x17 mm 85 g 8 Securiton Product Catalogue 2016 ASD 531/532/535

122 Relay I/F module for Special Fire Detectors RIM 36 Memory card module for ASD 535 The RIM 36 brings five (5) additional relay outputs to your Special Fire Detector (except ASD 535). Expansion limit is two (2) RIM 35 / 10 relays. Each relay can be assigned to any ASD event by programming with the ASD Config software. The module comes with mounting brackets, screws and ribbon cable. Max. relay output load: Dimensions (H x W x D): Weight: MCM / 1 / 30 V DC/A/W 95x58x17mm 85 g This Memory Card Module lets you trace up to 16 Million events and stores analogue values like smoke concentration and airflow of at least 83 days depending on the log interval. The module comes with mounting brackets, screws and ribbon cables and SD-Industrial memory card Dimensions (H x W x D) : Weight: 95x58x17 mm 43 g SD-Card Industrial 2GB SD-Industrial SD memory card (industrial) 2GB to use with MCM 35 or directly on-board in ASD 531 (AMB 31) and ASD 532 (AMB 32). Memory: 2 GB Temperature range: - 40 C C Serial I/F Module networking of Special Fire Detectors SIM 35 For the RS 485 networking of up to 250 Special Fire Detectors like ASD 535 or ASD 532. Using the ASD Config configuration software, all ASDs in the network can be visualised and configured from a PC. The module comes with mounting brackets, screws and ribbon cables Dimensions (H x W x D) : Weight: 95x58x17 mm 56 g Securiton Product Catalogue 2016 ASD 531/532/535 9

123 Serial Master Module for networking of Special Fire Detectors SMM 535 This interface connects the RS485 (over SIM 35) networked ASDs to a USB port of a PC. It is powered by the USB port Power Supply: Operating temperature: Dimensions (H x W x D): Weight: USB powered / 5 VDC -30 C to +60 C 82x89x55 mm 165 g Universal module support for Special Fire Detectors UMS 35 Universal module support for the attachment of BX-OI3, SCI 82 and others Dimensions (H x W x D): Weight: 130x11x94 mm 60 g 1.4. Demo and Test Equipment Democase for ASD 535 ASD 535 DCU ASD 535 Democase unit for training and sales presentations. Containing one ASD 535-4, alarm and fault simulation equipment, buzzer for alarm indication, USB cable for PC connection, power cable (swiss standard & international adapter type F) VE Dimensions (H x W x D): Weight: 580 x 430 x 230 mm 14 kg Democase for ASD 531/532 ASD 531/532 DCU ASD 531/532 Democase unit for training and sales presentations. Containing one ASD 531 and one ASD 532. For alarm and fault simulation. Equipped with buzzer for alarm indication, Ethernet cable for PC connection of ASD 532. Power cable (swiss standard & international adapter type F) Dimensions (H x W x D): Weight: 500 x 354 x 365 mm 15 kg 10 Securiton Product Catalogue 2016 ASD 531/532/535

124 2. Engineering and Configuration Tools Functional range partner level: Full access to all available ASD Config software functions. Functional range user level: Limited access for ASD Config software. Basically only read functions and the following write functions are possible: Change the current program (e.g. X01-X03, A11,B11 etc.) But no change of parameters in the X01-X03 programs. Project texts FW-download Adjust the RTC clock Change the tool language ASD Software Description Type Art. Nr. Planning and calculation software for planning symmetric and asymmetric sampling pipe topologies. (Subject to licence) Requirements: Windows XP / 7 / 8.1; 1 GB RAM; Hard disc space 50 MB ASD PipeFlow Update version only for clients which have a valid licence. Available as download from the Storebox. ASD PipeFlow Trial Test version with a runtime of 30 days. Available as download from the Storebox. ASD configuration tool license w/o USB Dongle. Partner License Extension ASD Config Networking (for an existing dongle) ASD configuration tool license with USB Dongle. Dongle & Partner License ASD Config Networking. ASD configuration tool license w/o USB Dongle. Partner License Extension ASD Config (for an existing dongle) ASD configuration tool license with USB Dongle. Dongle & Partner License ASD Config. ASD configuration tool license w/o USB Dongle. User License Extension ASD Config Networking, (for an existing dongle). ASD configuration tool license with USB Dongle. Dongle & User License ASD Config Networking ASD configuration tool license w/o USB Dongle. User License Extension ASD Config (for an existing dongle) ASD configuration tool license with USB Dongle. Dongle & User License ASD Config ASD PipeFlow ASD PipeFlow Upd ASD PipeFlow Trial PL_ASD-Conf_N D&PL_ASD-Conf_N PL_ASD-Conf D&PL_ASD-Conf UL_ASD-Conf_N D&UL_ASD-Conf_N UL_ASD-Conf D&UL_ASD-Conf VE VE VE VE VE VE VE VE USB 2.0 cable for connection between ASD 535 and PC KAB USB 45 USB 2.0 cable for connection between ASD 535 and PC for commissioning and maintenance via ASD Config Length: 4.5m Type: A-B Securiton Product Catalogue 2016 ASD 531/532/535 11

125 ASD 531 ASD 532 ASD 535 Project planning: Technical Document PipeFlow Technical Document PipeFlow Technical Document PipeFlow Configuration: FBS 25 PC FBL 25 PC BasiConfig (on board) EasyConfig (on board) or ASD Config (Software) Filter ASD Config (Software) EasyConfig (on board) or ASD Config (Software) ASD Config (Software) FBX 25 PC DFU 535L DFU 535XL Capillary tube TU 6 PVC Heating material All material DFA 25-1 DFA 25-2 DFA 25-3 ADB 01A ADB 02 Detonation flame arrester Automatic blow out device Detector box REK Securiton Product Catalogue 2016 ASD 531/532/535

126 3. Tubes and Fittings for Sampling Pipe 3.1. PVC Tubes and Fittings Tube TU 25 PVC Tube to create sampling pipes Colour: Length: Outer Diameter: PVC grey 5 m 25 mm Flexible Hose FH 25 PVC Flexible hose to create flexible sampling pipes. To be ordered in lengths per m Colour: Outer Diameter: PVC, reinforced grey 25 mm Bend 90 BE 25 PVC Bend 90 for tube TU 25 PVC Colour: Diameter: Packaging unit: PVC grey 25 mm 5 pieces Angle 90 AN PVC Angle 90 for tube TU 25 PVC. Whenever possible use bend BE 25 PVC because of its lower aerodynamic resistance Colour: Diameter: Packaging unit: PVC grey 25 mm 10 pieces Securiton Product Catalogue 2016 ASD 531/532/535 13

127 Angle 45 AN PVC Angle 45 for tube TU 25 PVC Colour: Diameter: Packaging unit: PVC grey 25 mm 10 pieces T-piece TP 25 PVC T-piece for tube TU 25 PVC or FH 25 PVC Colour: Diameter: Packaging unit: PVC grey 25 mm 10 pieces Cross CR 25 PVC Cross for tube TU 25 PVC or FH 25 PVC Colour: Diameter: Packaging unit: PVC grey 25 mm 10 pieces Socket SO 25 PVC Socket to connect two tubes TU 25 PVC or FH 25 PVC Colour: Diameter: Packaging unit: PVC grey 25 mm 10 pieces 14 Securiton Product Catalogue 2016 ASD 531/532/535

128 Screw-junction piece SJ 25 PVC Srew-junction for tubes TU 25 PVC or FH 25 PVC. For tube junctions in deep freeze warehouses in operating state because of the very long cure time in these temperatures. Junctions from PVC to ABS can be realized by combination of one SJ 25 PVC and one SJ 25 ABS Colour: Diameter: Packaging unit: PVC grey 25 mm 10 pieces End-cap EC 25 PVC End-cap for tube TU 25 PVC or FH 25 PVC Colour: Diameter: Packaging unit: PVC grey 25 mm 10 pieces Compressed-air connection CC 25 PVC Compressed-air connection for tube TU 25 PVC for cleaning the aspirating tube Colour: Diameter: PVC grey 25 mm Ventilation duct flange DF 25 PVC Flange for tube TU 25 PVC for the monitoring of ventilation ducts. Per duct 3 pieces of DF 25 PVC are required, 2 for the aspirating stub, 1 for the air recirculation. Please consider the planning hints Colour: Diameter: PVC grey 25 mm Securiton Product Catalogue 2016 ASD 531/532/535 15

129 3.2. ABS Tubes and Fittings Tube TU 25 ABS Tube to create sampling Colour: Length: Diameter: ABS light grey 5 m 25 mm Bend 90 BE 25 ABS Bend 90 for tube TU 25 ABS Colour: Diameter: Packaging unit: ABS light grey 25 mm 10 pieces Angle 90 AN ABS Angle 90 for tube TU 25 ABS. Whenever possible use bend BE 25 ABS because of its lower aerodynamic resistance Colour: Diameter: Packaging unit: ABS light grey 25 mm 10 pieces Angle 45 AN ABS Bend 45 for tube TU 25 ABS Colour: Diameter: Packaging unit: ABS light grey 25 mm 10 pieces 16 Securiton Product Catalogue 2016 ASD 531/532/535

130 T-piece TP 25 ABS T-piece for tube TU 25 ABS Colour: Diameter: Packaging unit: ABS light grey 25 mm 10 pieces Socket SO 25 ABS Socket to connect two tubes TU 25 ABS Colour: Diameter: Packaging unit: ABS light grey 25 mm 10 pieces Screw-junction piece SJ 25 ABS Screw-junction for tube TU 25 ABS. For tube junctions in deep freeze warehouses in operating state because of the very long cure time in these temperatures. Junctions from ABS to PVC can be realized by combination of one SJ 25 ABS and one SJ 25 PVC Colour: Diameter: Packaging unit: ABS light grey 25 mm 10 pieces End-cap EC 25 ABS End-cap for tube TU 25 ABS Colour: Diameter: Packaging unit: ABS light grey 25 mm 10 pieces Securiton Product Catalogue 2016 ASD 531/532/535 17

131 Compressed-air connection CC 25 ABS Compressed-air connection for tube TU 25 PVC for cleaning the aspirating tube Colour: Diameter: ABS grey 25 mm Ventilation duct flange DF 25 ABS Flange for tube TU 25 ABS for the monitoring of ventilation ducts. Per duct 3 pieces of DF 25 ABS are required, 2 for the aspirating stub, 1 for the air recirculation. Please consider the planning hints Colour: Diameter: ABS grey 25 mm 18 Securiton Product Catalogue 2016 ASD 531/532/535

132 3.3. Flex Pipe Materials Flexible tube FT 21 PA Flexible tube for sampling stub flex and equipment monitoring. To be ordered in length per m Colour: Outer Diameter: PA black 21.2 mm Self sealing coupling M20 SC 20ST PA Self sealing coupling straight to connect flexible tube (FT 21 PA) with a tube TU 25 XXX. To use together with the screw ring AD 20 XXX. Order for the connection of TU 25 XXX with FT 21 PA (e.g. with T-piece): TU 25 XXX TP 25 XXX AD 20 XXX SC 20ST PA FT 21 PA Pipe connection: Diameter: Packaging unit: 25 mm PA M20, 21,2 mm 10 pieces Self sealing coupling M20 SC 20BE PA Same as SC 20 ST PA but bent Pipe connection: Diameter: Packaging unit: 25 mm PA M20, 21,2 mm 10 pieces Adapter M20 AD 20 PVC AD 20 ABS Ring nut to use together with SC 20XX PA. The rings have to be glued into PVC/ABS sockets, T-pieces with diameter 25mm. Pipe connection: Diameter: Packaging unit: 25 mm PVC / ABS M20 10 pieces Securiton Product Catalogue 2016 ASD 531/532/535 19

133 3.4. Concrete Inserts Tube T-branch connection FT 32C Tube for concrete insertion. (To be purchased locally) PE (KRF 32 M) Colour: red Outer Diameter: 32 mm TP 32C T-branch connection for tube FT 32C. On demand Colour: Outer Diameter: PVC grey 32 mm Sampling point, T-piece SP 32C T T-piece with sampling point tube for FT 32C Colour: Outer Diameter: PVC grey 32 mm Sampling point, L-piece SP 32C L L-piece with sampling point for tube for FT 32C Colour: Outer Diameter: PVC grey 32 mm Sampling rosette a SP 15 PVC To be used together with sampling points SP 32T and SP 32C b Diameter a: Diameter b: 16 mm 30 mm PVC 20 Securiton Product Catalogue 2016 ASD 531/532/535

134 3.5. Copper Tube Materials Tube TU 22 Cu Tube to create sampling pipes for the ASD Outer Diameter: Length: Cu 22 mm 5m Bend 90 BE 22 Cu Bend for tube TU 22 Cu Outer Diameter: Cu 22 mm T-piece TP 22 Cu T-piece for tube TU 22 Cu Outer Diameter: Cu 22 mm Socket SO 22 Cu Socket to connect two tubes TU 22 Cu Outer Diameter: Cu 22 mm Adapter End-cap AD Cu Adapter for the junction of tubes TU 25 PVC and TU 22 Cu. To use together with adapter-socket AD 25-Inch xxx. Cu Outer Diameter: 22 mm ¾ EC 22 Cu End-cap for tube TU 22 Cu Outer Diameter: Cu 22 mm Securiton Product Catalogue 2016 ASD 531/532/535 21

135 3.6. Stainless Steel Tube Materials Tube TU 22 StSteel Tube to create sampling pipes Outer Diameter: Length: Stainless steel 22 mm 6m Bend 90 BE 22 StSteel Bend 90 for tube TU 22 StSteel Outer Diameter: Stainless steel 22 mm T-piece TP 22 StSteel T-piece for tube TU 22 StSteel Outer Diameter: Stainless steel 22 mm Socket SO 22 StSteel Socket to connect two tubes TU 22 StSteel Outer Diameter: Stainless steel 22 mm Adapter AD StSteel Adapter for the junction of tubes TU 25 PVC or TU 25 ABS and TU 22 StSteel. To use together with adapter-socket AD 25-Inch PVC or AD 25-Inch ABS Outer Diameter: Stainless steel 22 mm-¾ 22 Securiton Product Catalogue 2016 ASD 531/532/535

136 Adapter-socket Adapter-socket End-cap AD 25-Inch PVC Adapter-socket for the junction of tubes TU 25 PVC and TU 22 StSteel. To use together with adapter AD StSteel. PVC Diameter: 25 mm ¾ Packaging unit: 10 piece AD 25-Inch ABS Adapter-socket for the junction of tubes TU 25 ABS and TU 22 StSteel. To use together with adapter AD StSteel. ABS Diameter: 25 mm ¾ Packaging unit: 10 pieces EC 22 StSteel End cap for tube TU 22 StSteel Outer Diameter: Stainless steel 22 mm Securiton Product Catalogue 2016 ASD 531/532/535 23

137 3.7. Special Tubing Parts Tube TU 6 PVC Tube for sampling stub capillary Colour: Length: Outer Diameter: Inner Diameter: PA grey 5 m 6 mm 4 mm Reduction for sampling point Capillary RE 25-6 PVC Reduction 25mm to 6 mm (TU 25 PVC - TU 6 PVC) for sampling point type capillary Has to be glued into T-piece TP 25 PVC Diameter: Packaging unit: PVC 25-6 mm 10 pieces Reduction ¾ 25mm RE ¾-25 PVC RE ¾-25 ABS Reduction for ¾ tube to 25mm tube (TU 25 PVC or ABS). Diameter: PVC / ABS ¾ / 25 mm 24 Securiton Product Catalogue 2016 ASD 531/532/535

138 4. Sampling Points Sampling hole clip Clip x.x PA CLIP 2.0 PA CLIP 2.5 PA CLIP 3.0 PA CLIP 3.5 PA CLIP 4.0 PA CLIP 4.5 PA CLIP 5.0 PA CLIP 5.5 PA CLIP 6.0 PA CLIP 6.5 PA CLIP 7.0 PA Sampling hole on aspirating pipe (clip). Available with different diameter according to the project data. Only for PVC and ABS pipes with 25 mm diameter Packaging unit: 10 pieces Maintenance clip Hole diameter Type 2.0 mm CLIP 2.0 PA 2.5 mm CLIP 2.5 PA 3.0 mm CLIP 3.0 PA 3.5 mm CLIP 3.5 PA 4.0 mm CLIP 4.0 PA 4.5 mm CLIP 4.5 PA 5.0 mm CLIP 5.0 PA 5.5 mm CLIP 5.5 PA 6.0 mm CLIP 6.0 PA 6.5 mm CLIP 6.5 PA 7.0 mm CLIP 7.0 PA Clip-REV PA Clip without hole for revision purpose. Packaging unit: 10 pieces Pipe connection: 25 mm PA Securiton Product Catalogue 2016 ASD 531/532/535 25

139 Sampling-funnel SF ABS Sampling-funnel for tubes TU 25XXX. For sampling points exposed to high air current like monitoring of server racks or air conditioners Pipe connection: Hole diameter: 25 mm 5 mm ABS Rosette for sampling tube stiff a b SP 36 PVC SP 36 ABS For tubes TU 25 PVC/ABS to create the sampling point type sampling tube stiff with rosette. Has to be glued into the tubes TU 25 PVC or ABS. Various outer diameters (b) on demand available. Diameter a: Diameter b: Packaging unit: 21.5 mm 36 mm PVC / ABS 10 pieces Sampling point for ceiling duct Sampling point for ceiling duct (Set) SP M20 PVC SP M20 ABS Sampling point for ceiling ducts to connect flex sampling pipe (FT 21 PA.). To connect the flex sampling pipe FT 21 PA. Inclusive self sealing coupling SC 20ST PA. PVC / ABS Colour: white / grey Diameter: M20, 36mm Installation depth : PVC 25mm ABS 35mm SP M20 PVC-Set SP M20 ABS-Set Sampling point for ceiling ducts. Complete set incl. T-Piece TP 25XXX, flex sampling pipe (FT 21 PA) and sampling point (SP M20 XXX). Length sampling stub: PVC 1.5 m 26 Securiton Product Catalogue 2016 ASD 531/532/535

140 Sampling point Capillary (set) SP TU6 PVC Set To create the sampling point type Capillary. Complete capillary tube-set for the installation in sampling pipes TU 25 PVC. Incl. T-piece TP 25 PVC, reduction RE 25-6 PVC and capillary stub 1.5m Length: 1.5 m Colour: gray, RAL 7011 Diameter outside: 6 mm Diameter inside: 4 mm Sampling point with heating HEAT 3.0 PVC red HEAT 3.5 PVC blue HEAT 4.0 PVC green HEAT 4.5 PVC black HEAT 5.0 PVC brown To install the aspirating pipe in deep-freeze rooms to prevent the freezing of the aspirating holes. HEAT X.X is the relevant diameter for ASD PipeFlow-calculations (3.0/3.5/4.0/4.5/5.0mm) Pipe connection: Hole Diameter Type 5,7 mm HEAT 3.0 PVC 6,1 mm HEAT 3.5 PVC 6,3 mm HEAT 4.0 PVC 6,7 mm HEAT 4.5 PVC 7,1 mm HEAT 5.0 PVC 25 mm Sampling point with heating HEAT 3.0 ABS red HEAT 3.5 ABS blue HEAT 4.0 ABS green HEAT 4.5 ABS black HEAT 5.0 ABS brown Same as HEAT X.X PVC but in ABS. Pipe connection: Hole Diameter Type 5,7 mm HEAT 3.0 ABS 6,1 mm HEAT 3.5 ABS 6,3 mm HEAT 4.0 ABS 6,7 mm HEAT 4.5 ABS 7,1 mm HEAT 5.0 ABS 25 mm Securiton Product Catalogue 2016 ASD 531/532/535 27

141 Heat Resistor Heat Resistor Replacement for the sampling point with heating HEAT X.X PVC/ABS Resistor: 220 Ω Cable connection fitting CCF 25 PVC CCF 25 ABS Cable connection fitting set for T-junctions of the tubes in deep-freeze rooms. Pipe connection diameter: 25 mm Silicon litz wire SLW 0.5 wt (white) SLW 0.5 bk (black) Silicon litz wire 0.5mm² to connect the heating resistors in the heating nozzles HEAT X.X PVC/ABS.. Packaging unit: 100m Wiring connection unit WCU 535 For the introduction of the supply of the sampling point with heatin into the aspirating tube, with internal clamps. For more details please see the guidelines for deep freezewarehouses Dimensions (H x W x D): Pipe connection diameter: Weight: 80 x 82 x 85 mm PC 25 mm 317g 28 Securiton Product Catalogue 2016 ASD 531/532/535

142 5. Clamps, Glue and Cleaner Pipe clamp PC 25 PP Pipe clamp, type Goema for tubes TU 25XXX Pipe connection: 25 mm PP Pipe clamp PC 25 PVC Pipe clamp, type IKS for tubes TU 25XXX Pipe connection: Packaging unit: 25 mm PP 100 pieces Pipe clamp CLIC PC 25 PA Pipe clamp CLIC, type Egli Fischer for tubes TU 25XXX Pipe connection: 25 mm PA PVC glue Glue 125 PVC Glue to connect the PVC pipes and fittings Quantity: 125 ml PVC glue Glue 500 PVC Glue to connect the PVC pipes and fittings Quantity: 500 ml PVC glue Glue 1000 PVC Glue to connect the PVC pipes and fittings Quantity: 1000 ml Securiton Product Catalogue 2016 ASD 531/532/535 29

143 ABS glue Glue 500 ABS Glue to connect the ABS pipes and fittings Quantity: 500 ml Cleaner for PVC and ABS Cleaner 1000 To clean the pipes and fittings (PVC and ABS) before gluing Quantity: 1000 ml 30 Securiton Product Catalogue 2016 ASD 531/532/535

144 6. Accessories Detector Box REK 511 For the localization of a fire in a separate room, when a single ASD is monitoring several rooms. To use together with the SSD 515-Xs smoke detector. Has to be installed in every stub, which leads to a single room from the main tube. Operating voltage: VDC Ambient temperature: 0 C to + 50 C Dimensions (H x W x D): 186 x 122 x 85 mm Scattered light smoke detector for REK 511 SSD 515-1S sensitivity 1.2%/m SSD 515-2S sensitivity 0.6%/m SSD 515-3S sensitivity 0.3%/m The SSD 515-xS (Scattered Light Smoke Detector) is the smoke sensor for the accessory device REK 511 (full addressing) for the Aspirating Smoke Detector of the ASD and RAS product family. The SSD 515-xS operates according to the scattered light principle and is designed so that it optimally meets the specific requirements of smoke detection in association with an Aspirating Smoke Detector. The detector has alarm threshold tracking and is additionally available with various sensitivities. By choosing the appropriate detector sensitivity, applicationspecific detection properties of the Aspirating Smoke Detector are possible. Operating voltage: 18 to 28VDC Ambient temperature: -20 C to + 60 C Protection class: IP 44 Case colour: white Dimensions (D x H): 80 x 56mm Filter box small FBS 25 PC Filter box small including filter-mat. Inserted into the sampling pipe before ASD. To be used in slightly dusty rooms Dimensions (H x W x D): Pipe connection diameter: 80 x 82 x 85 mm PC 25 mm Securiton Product Catalogue 2016 ASD 531/532/535 31

145 Filter mat small for filter box small FBS 25 PC EFM 5er Filter-mat for filter box small. Packaging of 5 pieces Dimensions (H x W x D): 80 x 80 x 20 mm Filter box large FBL 25 PC Filter box large including filter-mat. Inserted into the sampling pipe before ASD. To be used in dusty rooms Dimensions (H x W x D): Pipe connection diameter: 120 x 122 x 85 mm PC 25 mm Filter mat large for filter box large FBL 25 PC EFM 5er Replacement filter mat for the filter box large. Packaging of 5 pieces : Dimensions (H x W x D): 117 x 80 x 80 mm Filter box extra large FBX 25 PC Filter box extra large including 2 filter-mats and 1 holder for the filter-mat. Inserted into the sampling pipe before ASD. To be used in very dusty rooms Dimensions (H x W x D): Pipe connection diameter: 250 x 160 x 90 mm PC 25 mm Filter mat for filter box extra large Filter-Mat X Filter-mat for filter box extra large Packaging of one piece. Dimensions (H x W x D) : 155 x 85 x 65 mm Holder for Filter-Mat X Holder Filter-Mat X 1 holder is included in the FBX 25 PC for the filter-mat at the bottom side Securiton Product Catalogue 2016 ASD 531/532/535

146 Dust filter unit large DFU 535L Dust filter unit large. To be used in dusty rooms. Inserted into the sampling pipe before ASD Dimensions (H x W x D): Pipe connection diameter: Weight : 165 x 220 x 220 mm steel 37, black 40/25 mm 1600g Replacement cartridge for DFU 535L DFU 535L RC Replacement cartridge for dust filter unit large Weight : 170g Dust filter unit extra large DFU 535XL Dust filter unit extra large. To be used in very dusty rooms. Inserted into the sampling pipe before ASD Dimensions (H x W x D): Pipe connection diameter: Weight: 230 x 250 x 250 mm steel 37, black 40/25 mm 2000g Replacement cartridge for DFU 535XL DFU 535XL RC Replacement cartridge for dust filter unit extra large Weight: 520g Dirt trap box DTB 25 PC Dirt trap box To be used in very dusty rooms. Inserted into the sampling pipe before dust filter of any type and ASD Dimensions (H x W x D) : Pipe connection diameter: 160 x 250 x 90 mm PC 25 mm Securiton Product Catalogue 2016 ASD 531/532/535 33

147 Water retaining box WRB 25 PVC WRB 25 ABS Water retaining box standard Used in rooms with high humidity. Inserted into the sampling pipe before DTB 25 PC (when used), any types of dust filters (when used) and ASD. Dimensions (H x W x D): Pipe connection diameter: 335 x 250 x 90 mm PC 25 mm Air cooler and water separator LK 35 PVC LK 35 ABS Is used as an air cooler when the sampling pipe is in a room >60 C. Can also be used as a water separator in rooms with high amount of air humidity and / or condensing water because of temperature differences. For more details see the technical documentation. Dimensions (H x W x D): Weight: VdS-Approval: CPD-Approval: 1000 x 730 x 80 mm Copper pipe d=22x1 mm 8 Kg G CPD Automatic blow out device ADB 01A The automatic blow-out device ADB-01A is used in areas which are polluted with a high amount of dust- and dirt particles. With the blow-out device, 1 sampling pipe is automatically blown out and cleaned, to prevent fault messages caused by clogged aspiration points and also to avoid false alarms. At the same time, the life-time of the optical scattered-light-detector located in the aspiration system is substantially increased Mains voltage: Pressure connection: Dimensions (H x W x D): Pipe connection diameter: 15 to 30 V DC (constant) 4 bar constant 275 x 380 x 180 mm 25 mm 34 Securiton Product Catalogue 2016 ASD 531/532/535

148 Automatic blow out device ADB 02 Same as ADB 01A except: Version for 2 sampling pipes Mains voltage: Pressure connection: Dimensions (H x W x D): Pipe connection diameter: 15 to 30 V DC (constant) 4 bar constant 500 x 500 x 210 mm 25 mm Manual ball valve MV 25 PVC MV 25 ABS Manual ball valve for revision and cleaning works with compressed air. Pipe connection diameter: PVC 25 mm Detonation flame arrester DFA 25-3 Detonation flame arrester for explosion zones. Equipment category IIC. 2 pieces are needed per sampling tube. For more details see the technical documentation Pipe connection diameter: 25 mm Detonation flame arrester DFA 25-2 Same as DFA 25-3 but equipment category IIB Pipe connection diameter: 25 mm Detonation flame arrester DFA 25-1 Same as DFA 25-3 but equipment category IIA Pipe connection diameter: 25 mm Securiton Product Catalogue 2016 ASD 531/532/535 35

149 Noise reduction housing Insulation housing The noise insulation housing is used as an accessory part for the aspirating smoke detector ASD 535 in areas where a low level of noise is required. If the ventilator noise from the aspirating smoke detector is found to be disruptive and changing the location of the evaluation unit is not possible, the aspirating smoke detector can be integrated into a noise insulation housing. Sound pressure level: 20 db (A) Dimensions (H x W x D) : 500 x 500 x 300 mm Steel sheet Weight : 21,5 kg Protection class: IP Additional housing for SecuriRAS ASD 535 ASD Housing Ex The additional housing is designed for the integration of an aspirating smoke detector ASD 535. The additional housing should be used as additional personal protection in explosive areas. If there is danger of operations related damage (e.g. lift truck operations) to the aspirating smoke detector, the additional housing can serve as a mechanical protection measure Cleaning Kit SecuriRAS ASD Steel sheet Dimensions (H x W x D): 500 x 500 x 300 mm Weight: 21 kg Protection class: IP 54 Cleaning Kit Transport case for Cleaning Kit The cleaning kit is generally used for service and maintenance work on aspirating smoke detectors. It is used for cleaning suction pipes that can be blown out and aspirated at high power. Adaptation to the respective suction pipes is possible with the supplied accessory materials. Supply voltage: 230 VAC Power consumption: 1100 W Compressed air capacity: Air volume" approx l/minr Operating pressure approx 230 mbar Weight (without accessories): 3400 g 36 Securiton Product Catalogue 2016 ASD 531/532/535

150 7. Spare Parts Main board for ASD 531 AMB 31 Repair exchange for the ASD Dimensions (H x W x D): 250 x 160 x 15 mm Main board for ASD 532 AMB 32 Repair exchange for the ASD Dimensions (H x W x D): 250 x 160 x 15 mm Main board for ASD and -3 AMB 35-1 Repair exchange for the ASD and Dimensions (H x W x D): 125 x 176 x 20 mm Main board for ASD and -4 AMB 35-2 Repair exchange for the ASD and Dimensions (H x W x D): 125 x 176 x 20 mm Basic control board for standard display of ASD and -2 BCB 35 Repair exchange for the standard display unit (without smoke level display) Dimensions (H x W x D): 90 x 59 x 9 mm Basic control board for advanced display of ASD and -4 ACB 35 Repair exchange for the advance display unit (with smoke level display) Dimensions (H x W x D): 90 x142 x 9 mm Replacement battery CR 2032 Replacement battery for AMB 31, AMB 32 and AMB Securiton Product Catalogue 2016 ASD 531/532/535 37

151 Air flow sensor for ASD 531 and ASD 532 AFS 32 Repair exchange for air flow sensor for ASD 531 / 532 incl. connection wire Air flow sensor for ASD 535 AFS 35 Repair exchange for air flow sensor for ASD 535 incl. connection wire Dimensions (H x W x D): 15 x 14 x 115 mm Aspirating fan unit for ASD 531 and ASD 532 AFU 32 Repair exchange for the aspirating fan unit complete for ASD 531/ Aspirating fan unit for ASD 535 AFU 35 Repair exchange for the aspirating fan unit complete for ASD Dimensions (H x W x D): 138 x 185 x 58 mm Rotary Snap Lock for ASD 531/532/535 RSL 35 ) Repair exchange for the ASD 531/532/535 housing Packaging unit: ABS / steel 4 pieces Insect protection screen for ASD 531/532/535 IPS 35 Insect protection screen for the ASD 531/532/535 housing Packaging unit: steel 2 pieces 38 Securiton Product Catalogue 2016 ASD 531/532/535

152 8. Product Type Index A ACB AD 20 ABS AD 20 PVC AD Cu AD StSteel AD 25-Inch ABS AD 25-Inch PVC ADB 01A ADB ADW 531/532 DCU ADW 535 DCU AFS AFS AFU AFU AMB AMB AMB AMB AN ABS AN PVC AN ABS AN PVC ASD ASD ASD 535 Verschl... 7 ASD ASD ASD ASD ASD Housing Ex ASD PipeFlow ASD PipeFlow Test ASD PipeFlow Upd B BCB BE 22 Cu BE 22 StSteel BE 25 ABS BE 25 PVC C CC 25 ABS CC 25 PVC CCF 25 ABS Cleaner Cleaning Kit CLIP 2.0 PA CLIP 2.5 PA CLIP 3.0 PA CLIP 3.5 PA CLIP 4.0 PA CLIP 4.5 PA CLIP 5.0 PA CLIP 5.5 PA CLIP 6.0 PA CLIP 6.5 PA CLIP 7.0 PA Clip-REV PA CR CR 25 PVC D D&PL_ASD-Conf D&PL_ASD-Conf_N D&UL_ASD-Conf D&UL_ASD-Conf_N DF 25 ABS DF 25 PVC DFA DFA DFA DFU 535L DFU 535L RC DFU 535XL DFU 535XL RC DTP 25 PC E EC 22 Cu EC 22 StSteel EC 25 ABS EC 25 PVC F FBL 25 PC FBL 25 PC EFM 5er FBS 25 PC FBS 25 PC EFM 5er FH 25 PVC Filter-Mat X FT 21 PA FT 32C G Glue 1000 PVC Glue 125 PVC Glue 500 ABS Glue 500 PVC H HEAT 3.0 ABS HEAT 3.0 PVC HEAT 3.5 ABS HEAT 3.5 PVC HEAT 4.0 ABS HEAT 4.0 PVC HEAT 4.5 ABS HEAT 4.5 PVC HEAT 5.0 ABS HEAT 5.0 PVC Heat Resistor I IPS K KAB USB L LK 35 - ABS LK 35 - PVC M MCM MV 25 ABS MV 25 PVC N Noise insulation housing P PC 25 PA PC 25 PP PC 25 PVC PL_ASD-Conf PL_ASD-Conf_N R RE 25-6 PVC REK RIM RIM S SC 20BE PA SC 20ST PA SD-Industrial... 9 SF ABS SIM SJ 25 ABS SJ 25 PVC SLM SLW 0.5 bk SLW 0.5 wt SMM SO 22 Cu SO 22 StSteel SO 25 ABS SO 25 PVC SP 15 PVC SP 32C L SP 32C T SP 36 ABS SP 36 PVC SP M20 ABS SP M20 ABS-Set SP M20 PVC SP M20 PVC-Set SP TU6 PVC Set Securiton Product Catalogue 2016 ASD 531/532/535 39

153 SSD SSD 515-1S SSD 515-2S SSD 515-3S SSD SSD T TP 22 Cu TP 22 StSteel TP 25 ABS TP 25 PVC TP 32C Transport case for Cleaning Kit TU 22 Cu TU 22 StSteel TU 25 ABS TU 25 PVC TU 6 PVC U UL_ASD-Conf UL_ASD-Conf_N UMS W WCU WRB 25 ABS WRB 25 PVC X XLM Securiton Product Catalogue 2016 ASD 531/532/535

154 Securiton Product Catalogue 2016 ASD 531/532/535 41

155 42 Securiton Product Catalogue 2016 ASD 531/532/535

156 SecuriBeam BSD 535 / ILIA Product Catalogue 2016

157 Content 1. Beam Detector BSD SecuriBeam BSD Accessories for BSD Beam Detector ILIA SecuriBeam ILIA SecuriBeam ILIA Dust Pro Accessories for ILIA Product Type Index Securiton Product Catalogue 2016 BSD535 / ILIA

158 Introduction Beam smoke detector based on the reflection principle Beam Smoke Detector The beam smoke detector systems consist of a transmitter/ receiver unit or reflector which is mounted on the opposite wall. The infrared light beam from the transmitter is sent back to the reflector. Applications Thanks to the linear design of transmitter and receiver or reflector, the SecuriBeam can be deployed wherever conventional point detectors cannot be used due to structural issues or when such detectors are not able to guarantee optimal protection. Examples of such applications: Large warehouses and production halls Covered inner courtyards (atriums) Reception halls Warehouses Attics in churches Cinemas, theatres Production All Securiton fire alarm systems, system components and detectors are developed and manufactured in Europe and in compliance with the most recent European standards, as well as representing the cutting edge of technology based upon the most up-to-date scientific knowledge. Product The descriptions and technical data included in this catalogue are up-to-date at the time of release. We reserve the right to make alterations to them, particularly where justified by technological advancements. The illustrated products may also differ visually from the products supplied as a result of continuous further development of products. The layout of this catalogue is subject to copyright. The copying or reuse of text, illustrations and photos in any media (e.g. print, CD-ROM, Internet, etc.) contained within this catalogue - also in an abridged form - is only allowed with our explicit written permission. We assume no liability for typographic errors and obvious mistakes. Please quote the relevant item numbers when making enquiries or placing an order. Delivery conditions are regulated in the General Terms and Conditions of Securiton AG for Export Deliveries Securiton Product Catalogue 2016 BSD535 / ILIA 3

159 How to read the catalogue Example of a typical entry for an item Type & Article Number Please quote this number when making an enquiry or ordering Optical Smoke Detector BSD 535 Beam Smoke Detector incl. BRE 535 The Beam Detector BSD 535 including one reflector BRE 535 is particularly suited for indoor smoke detection in industrial sheds - palletised and traditional warehouses, garages, supermarkets, mega stores, cinemas, theatres, conference rooms, trade exhibition centres, public buildings with large flows of people in general and any other large civil and industrial spaces of any shape Operating voltage: 12 V DC 30 V DC Ambient temperature detection unit: -10 C to +55 C Operating Distance: m Detector protection: IP 31 Optical block protection: IP 51 Evaluation: Smoke Illustration Description and technical data 4 Securiton Product Catalogue 2016 BSD535 / ILIA

160 1. Beam Detector BSD 1.1. SecuriBeam BSD 535 Beam Smoke Detector incl. 1 BRE 535 BSD The Beam Detector BSD 535 including one reflector BRE 535 is particularly suited for indoor smoke detection in industrial sheds - palletised and traditional warehouses, garages, supermarkets, mega stores, cinemas, theatres, conference rooms, trade exhibition centres, public buildings with large flows of people in general and any other large civil and industrial spaces of any shape. Operating voltage: 12 V DC 30 V DC Ambient temperature detection unit: -10 C to +55 C Operating Distance: m Detector protection: IP 31 Optical block protection: IP 51 Evaluation: Smoke Securiton Product Catalogue 2016 BSD535 / ILIA 5

161 1.2. Accessories for BSD Beam detector Reset Unit BRU 535 The BRU-535 is a reset unit, with which the BDS 535 can be local deactivated. The BRU 535 can be connected to the BRC 535 Dimensions (H x W x D): 90,5x90,5x40,5 mm Weight: 110g Index of Protection: IP 40 Colour: Light gray Beam detector Remote Control BRC 535 The BRC 535 is an aid tool for the installation, start up and maintenance of the Securiton linear smoke detector, version BSD 535 and up Dimensions (H x W x D): Weight: 173x110x33 mm 465 g Beam detector Reflector sun-shield Protection BRP 535 The reflector sun-shield protects the system against unwanted incident light radiation from corners more than 40 to the optical axis (Vertical to the reflecting surface) of the reflector. Two grid screens can be set on top of each other. Then the system is protected against unwanted incident light radiation up to 20 to the optical axis of the reflector Dimensions (H x W x D): Weight: 102x102x40 mm 80g Beam detector Reflector Extension BRE Beam detector Reflector Extension for BSD Dimensions (H x W x D): Weight: 130x100x18 mm 70 g 6 Securiton Product Catalogue 2016 BSD535 / ILIA

162 Beam detector Reflector Extension BRE Beam detector Reflector Extension for BSD 535 (3 pcs) Dimensions (H x W x D): Weight: 230x230x18 mm 210 g Beam detector Articulated Bracket BAB 535 Articulated Bracket if a 90 installation on the wall is not possible Dimensions (H x W x D): Weight: 166x130x57 mm 995 g Securiton Product Catalogue 2016 BSD535 / ILIA 7

163 2. Beam Detector ILIA 2.1. SecuriBeam ILIA ILIA with smoke/fire detection ILIA S/E The transmitter / receiver system ILIA S/E is particularly suited for indoor smoke and fire detection. Thanks to the linear design with transmitter and receiver, it may be used wherever structural situations prevent the installation of conventional point detectors or where the latter can no longer guarantee optimal protection SecuriBeam ILIA Dust Pro Operating voltage: 9,6 V DC - 32 V DC Ambient temperature detection unit: -20 C to +65 C Operating Distance: m Detector protection: IP 65 Evaluation: Smoke / Fire ILIA DUST Detector for polluted areas ILIA S/E DUSTP The transmitter / receiver system ILIA S/E Dust Pro is particularly suited for indoor smoke and fire detection in extremely dusty environments. Thanks to the linear design with transmitter and receiver, it may be used wherever structural situations prevent the installation of conventional point detectors or where the latter can no longer guarantee optimal protection Operating voltage: 9,6 V DC - 32 V DC Ambient temperature detection unit: -20 C to +65 C Operating Distance: m Detector protection: IP 65 Evaluation: Smoke / Fire 8 Securiton Product Catalogue 2016 BSD535 / ILIA

164 2.3. Accessories for ILIA Controll and I/F Unit for 2 systems ILIA KE/2 Control unit for 2 x ILIA S/E for stub connection. All adjustment, testing and maintenance work can be simply and reliably performed on the easily accessible control unit Dimensions (H x W x D): 145x177x68 mm Weight: 375g Colour: RAL 5004 Controll and I/F Unit for 2 DUST systems ILIA KE/2 DUSTP Control unit for 2 x ILIA DUSTP S/E for stub connection, in extremely dusty environments. All adjustment, testing and maintenance work can be simply and reliably performed on the easily accessible control unit. The control unit ILIA KE/2 DUSTP is design for extremely dusty environments Dimensions (H x W x D): 145x177x68 mm Weight: 375g Colour: RAL 5004 Extension unit for 6 systems ILIA KEE/6 ILIA: Control unit extension board for six additional ILIA detectors for ring circuit connection. ILIA Dust Pro: Control unit extension board for six additional ILIA Dust Pro detectors for ring circuit connection. When pre-signals are activated only three additional ILIA Dust Pro can be used Dimensions (H x W x D): Weight: 120x55x35 mm 50 g Protective Housing ILIA SGH Protective case for extremely dusty environments. - Additional security for permanent acid concentrations in the air or aggressive dust concentrations - Protection against misalignment during cleaning and Disinfection Protection class: IP 65 Dimensions (H x W x D) : 303x303x260 mm Weight: 2100 g Securiton Product Catalogue 2016 BSD535 / ILIA 9

165 Attachment with disc for protective housing ILIA AGH AS Attachment for the ILIA SGH protective housing. Nano sealed pane for easier cleaning Adjustable wall/ceiling holder ILIA WHE Adjustable wall/ceiling holder for ILIA S/E Dimensions (H x W x D) : 480x mm Material : Metal Colour : black, RAL Securiton Product Catalogue 2016 BSD535 / ILIA

166 3. Product Type Index B BAB BRC BRE BRE BRP BRU BSD I ILIA AGH AS ILIA KE/ ILIA KE/2 DUSTP... 9 ILIA KEE/ ILIA S/E... 8 ILIA S/E DUSTP... 8 ILIA SGH... 9 ILIA WHE Securiton Product Catalogue 2016 BSD535 / ILIA 11

167 12 Securiton Product Catalogue 2016 BSD535 / ILIA

168 SecuriSens ADW 535 Product Catalogue 2016

169 Content 1. Line type heat detector Demo and Test Equipment Software Accessories Copper parts Stainless steel parts Teflon parts Polyamide parts Installation material Accessories for Ex-Zones Spare Parts Product Type Index Securiton Product Catalogue 2016 ADW535

170 Introduction When it comes to safety, don t play with fire Danger is never far away in locations where fires are possible, with human life, assets and data being put at risk. Securiton has decades of experience in the area of fire detection and fire alarm systems. The SecuriSens ADW 535 comes into its own where conventional fire detectors reach their physical limits. It copes well with both extreme temperatures and constantly high atmospheric humidity, whilst precise measurements are also possible when corrosive gases and contaminated air are present. Effective fire protection The ADW 535 is an integrated line type heat detector with a response behaviour based on heat differential and/or maximum heat. Thanks to its self-check feature and the periodic, automatic test, the ADW 535 is particularly suitable for use in applications where the legally prescribed functional and maintenance checks cannot be performed due to the given ambient conditions or only with difficulty. With the installation of an XLM 35 SecuriLine extended line module, the ADW 535 line type heat detector can be easily connected to the SecuriFire (SecuriLine extended) and Integral (X-Line) fire alarm systems via the addressable loop. The response behaviour of the ADW 535 is tested in compliance with EN Class A1I, A2l and Bl from Firmware V Class A1I to GI (in preparation) Application depending sensing tubes Depending on the application, various sensing tubes are used (all of which have VdS approval): Copper: standard applications, property surveillance Stainless steel: food industry and high temperature applications PTFE (Teflon): aggressive ambient conditions (e.g. chemical industry) Powerful software tools, efficient commissioning ADW HeatCalc is used for sketching the sensing tube system and calculating the necessary system settings. The PC tool is rounded off by the parts list and report for the plant documentation. Diverse setting options are offered directly on the device via EasyConfig or using the comfortable ADW Config tool for perfect adaptation to existing environmental conditions Securiton Product Catalogue 2016 ADW535 3

171 How to read this catalogue Example of a typical entry for an item Type & Article Number Please quote this number when making an enquiry or ordering. Sensing tube TU 6/4 PTFE 25 Tube to create the sensor part. (delivery in units of 25m) Diameter outside Diameter inside Length Material 6 mm 4 mm 25 m teflon Illustration Description and technical data 4 Securiton Product Catalogue 2016 ADW535

172 1. Line type heat detector Line Type Heat detector ADW ADW ADW one sensing tube ADW two sensing tubes The SecuriSens ADW 535 line-type heat detector combines a proven functional principle with the latest developments in sensor and processor technology. A sensing tube filled with normal air is installed in the area to be monitored. A fully electronic pressure sensor permanently records the pressure in the sensing tube and compares it with the alarm criteria. Commissioning and configuration is done either directly on the device or via the comfortable ADW Config software tool for a perfect adaptation to existing environmental conditions. For planning the ADW HeatCalc software allows an optimized design of any installation. Operating voltage: 9 to 30 V DC Length of sensing tube: 115 m Relay contact: 50 VDC/1A (UL 30 VDC) Ambient temperature evaluation unit: -30 C to +70 C Ambient temperature sensing tube*: - 40 C to +180 C Dimensions (H x W x D): 134 x x mm Protection category of case: IP 65 Case Colour: Light grey RAL Charcoal RAL Weight: 1.6 kg VdS-Approval: G *: Lower or higher temperature ranges are also possible subject to consultation with the manufacturer Securiton Product Catalogue 2016 ADW535 5

173 Line Type Heat detector ATEX ADW 535-1HDx ADW 535-1HDx one sensing tube ADW 535-2HDx two sensing tubes The SecuriSens ADW 535 line-type heat detector combines a proven functional principle with the latest developments in sensor and processor technology. A sensing tube filled with normal air is installed in the area to be monitored. A fully electronic pressure sensor permanently records the pressure in the sensing tube and compares it with the alarm criteria. Commissioning and configuration is done either directly on the device or via the comfortable ADW Config software tool for a perfect adaptation to existing environmental conditions. For planning the ADW HeatCalc software allows an optimized design of any installation. ADW 535-2HDx The HDx versions are For ATEX applications and very harsh ambient conditions. Operating voltage: 9 to 30 V DC Length of sensing tube: 115 m Relay contact: 50 VDC/1A (UL 30 VDC) Ambient temperature evaluation unit: -30 C to +70 C Ambient temperature sensor tube*: -40 C to +180 C Dimensions (H x W x D): 260 x 203 x 134 mm Protection category of case: IP 66 Case Colour: Graphite black RAL 9011 Platinum grey RAL 7036 Weight: ADW 535-1HDx 3,05 Kg ADW 535-2HDx 3,42 kg *: Lower or higher temperature ranges are also possible subject to consultation with the manufacturer External Temperature Sensor ART For the temperature compensation the external temperature sensor ART 535 is to be used and placed in the monitored area. For temperature ranges and for EX applications a special version (ART Ex 400 C) is to be used Temperature range: - 50 to 200 C Length cable: 10 m 6 Securiton Product Catalogue 2016 ADW535

174 Loop I/F module for Special Fire Detectors XLM 35 With the installation of an XLM 35, special fire detectors like ADWs can be ideally connected via the addressable loop to the SecuriFire fire alarm systems. The normative alarm transmission to the superordinate FACP is then accomplished via the XLM 35. The module comes with mounting brackets, screws and ribbon cable. The XLM 35 module allows also central configuration of special fire detectors with the Config Over Line function Operating Voltage from AMB 35: Maximum power consumption : Dimensions (H x W x D): Weight: 5 V DC 20 ma 155 x 108 x 64 mm 62 g Relay I/F module for Special Fire Detectors RIM 36 The RIM 36 brings five (5) additional relay outputs to your Special Fire Detector. Expansion limit is two (2) RIM 35 / 10 relays. Each relay can be assigned to any ADW event by programming with the ADW Config software. The module comes with mounting brackets, screws and ribbon cable Max. relay output load: Dimensions (H x W x D): Weight: 50 / 1 / 30 V DC/A/W 95x58x17mm 85 g Serial I/F Module networking of Special Fire Detectors SIM 35 For the RS 485 networking of up to 250 Special Fire Detectors like ADW 535. Using the ADW Config configuration software, all ADWs in the network can be visualised and configured from a PC. The module comes with mounting brackets, screws and ribbon cables Dimensions (H x W x D) : Weight: 95x58x17 mm 56 g Securiton Product Catalogue 2016 ADW535 7

175 Serial Master Module for networking of Special Fire Detectors SMM 535 This interface connects the RS485 (over SIM 35) networked ADWs to a USB port of a PC. It is powered by the USB port Power Supply: Operating temperature: Dimensions (H x W x D): Weight: USB powered / 5 VDC -30 C to +60 C 82x89x55 mm 165 g 1.1. Demo and Test Equipment Democase for ADW 535 ADW 535 DCU Democase ADW 535 for training and sales presentations Weight: Dimensions(HxWxD): 9,95 kg 500 x 200 x 360 mm 8 Securiton Product Catalogue 2016 ADW535

176 2. Software Functional range partner level: Full access to all available ADW Config software functions. Functional range user level: Limited access for ADW Config software. Basically only read functions and the following write functions are possible: Change the current program (e.g. X01-X03, A11, A21 etc.) But no change of parameters in the X01-X03 programs. Project texts FW-download Adjust the RTC clock Change the tool language ASD Software Description Type Art. Nr. ADW calculation& planning tool, Configuration and test software. Download from the Storebox ADW configuration tool license w/o Dongle. Partner License Extension ADW Config Networking (for an existing dongle) ADW configuration tool license with Dongle. Dongle & Partner License ADW Config Networking ADW configuration tool license w/o Dongle. Partner License Extension ADW Config (for an existing dongle) ADW configuration tool license with Dongle. Dongle & Partner License for ADW Config ADW configuration tool license w/o Dongle. User License Extension ADW Config Networking (for an existing dongle) ADW configuration tool license with Dongle. Dongle & User License ADW Config Networking. ADW configuration tool license w/o Dongle. User License Extension ADW Config (for an existing dongle) ADW configuration tool license with Dongle Dongle & User License ADW Config ADW-HeatCalc PL_ADW-Conf_N D&PL_ADW-Conf_N PL_ADW-Conf D&PL_ADW-Conf UL_ADW-Conf_N D&UL_ADW-Conf_N UL_ADW-Conf D&UL_ADW-Conf VE VE VE VE VE VE VE VE Securiton Product Catalogue 2016 ADW535 9

177 3. Accessories Copper tube Stainless steel tube Teflon tube Flexible polyamide hose Application areas Standard environments High temperature environments Aggressive environments For the flexible connection between ADW and copper/stainless steel tube Properties Application areas Temperature resistance + + Chemical resistance Corrosion resistance + standard industrial applications Car park halls Loading platforms Road tunnels railway tunnels underground railway tunnels Temperature resistance Chemical resistance Corrosion resistance + + Fertiliser industry Rubber industry Plastics processing industry Food processing industry Textile industry cellulose industry Diameter outside (mm) Diameter inside (mm) Tube length 10 to 115 m 10 to 115 m (depending on (200 m not acc. EN) (200 m not acc. EN) application) Max. distance between pipe clamps Distance between pipe clamps and Screw-junction piece Ambient temperature -260 C to +150 C -110 C to +300 C (higher temperatures on demand) Temperature resistance + + Chemical resistance Corrosion resistance Bioengineering Chemical industry Semiconductor industry Laboratory Engineering Medical engineering Pharmaceutical industry Temperature resistance + Chemical resistance + + Corrosion resistance + + As supply line to the detction area or for the thermal decoupling to 105 m (150 m not acc. EN) 0 to 20 m 0,8 m to 1,2 m 0,8 m to 1,2 m 0,5 m 0,5 m 10 cm each side 10 cm each side 20 cm each side 20 cm each side -70 C to C (PVDF -40 to +150 C) -40 C to +100 C Applicable in A1-G A1-G A1, A2 and C A1-G heat classes Material Cu-DHP R250 Stainless steel (1.4571) Polytetrafluorethylen Polyamide PA 12 (PTFE) Screw junction piece Brass Stainless steel (1.4571) PVDF or Brass - End plug Brass Stainless steel (1.4571) PVDF or Brass - Stiffener sleeve - - Brass when used with Brass-junctions Brass or Stainless steel (1.4571) Test coil Cu-DHP R250 Stainless steel (1.4571) - - Pipe clamp Polyamide (max. 85 C) Polypropylen (max. 100 C) or Brass Polyamide (max. 85 C) Polypropylen (max. 100 C) or Stainless steel (1.4571) Polyamide (max. 85 C) Polypropylen (max. 100 C) Brass or Stainless steel (1.4571) Polyamide (max. 85 C) Polypropylen (max. 100 C) Sensing tube connection ADW (standard delivery brass) Brass Brass (First part of tube Polyamide) Necessary accessories Brass; special adapter available AD ADW TU 6/4 Connection set Screw-junction piece Same number as pipes Per test coil +2 (If test coil connected Same number as pipes Per test coil +2 (If test coil connected - Same number as hoses -1-1 per hose (If test coil connected at ADW +1) at ADW +1) at ADW +1) End plug 1 per sensing tube 1 per sensing tube 1 per sensing tube - Stiffener sleeve per tube part (only for brass junctions) 2 per hose part Pipe clamps Ca. 1 clamp per m depending on clamp distance ( m) 1,25 clamps per m depending on clamp distance ( m) Brass 2 clamps per m Ca. 1 clamp per m depending on clamp distance ( m) 10 Securiton Product Catalogue 2016 ADW535

178 3.1. Copper parts Standard sensing tube for applications with normal ambient temperatures C (When used at 100 C and above, use metal pipe clamps). Sensing tube copper 5/4mm TU 5/4 Cu Tube to create the sensor part (straight piece 5.5m) Diameter outside: Diameter inside: Length: 5 mm 4 mm 5,5 m copper Sensing tube copper 5/4mm TU 5/4 Cu 50 Tube to create the sensor part, 1 pcs. (coil 50m) Diameter outside: Diameter inside: Length: 5 mm 4 mm 50 m copper Screw Junction straight for TU 5/4 Cu SJ 5/4 CuZn Screw junction straight for TU 5/4 Cu For pipe diameter: 5 mm brass End plug for Junction straight for SJ 5/4 CuZn EP 5/4 CuZn End plug for SJ 5/4 CuZn brass T-Junction for TU 5/4 Cu TJ 5/4 CuZn T-Junction for TU 5/4 Cu brass Securiton Product Catalogue 2016 ADW535 11

179 Sensing-Coil of TU 5/4 Cu 5 m SC 5/4 Cu Sensing coil of TU 5/4 Cu Length: 5 m copper Test-Coil of TU 5/4 Cu 10 m TC 5/4 Cu Test coil of TU 5/4 Cu Including 4m of hardplastic tube FH 5/3 PA and junctions to connect the test coil with the ADW and the sensing tube. Length: 10 m copper 12 Securiton Product Catalogue 2016 ADW535

180 3.2. Stainless steel parts Sensor tube for applications in corrosive environments, especially in the food industry for hygienic reasons C (when used at 100 C and above, use metal pipe clamps). Sensing tube stainless steel 5/4mm TU 5/4 St Tube to create the sensor part (straight piece 6m) Diameter outside: Diameter inside: Length: 5 mm 4 mm 6 m stainless steel Screw Junction straight for TU 5/4 St SJ 5/4 St Screw junction straight for TU 5/4 St For pipe diameter: 5 mm stainless steel End plug for SJ 5/4 St EP 5/4 St End plug for SJ 5/4 St stainless steel T-Junction for TU 5/4 St TJ 5/4 St T-Junction for TU 5/4 St stainless steel Protection screw PS TU 5/4 St Protection screw for the connection of sensing tube TU 5/4 St to the ADW 535 evaluation unit Securiton Product Catalogue 2016 ADW535 13

181 Sensing-Coil of TU 5/4 St SC 5/4 St Sensing coil of TU 5/4 St Length: 5 m stainless steel Test-Coil of TU 5/4 St TC 5/4 St Test coil of TU 5/4 St Including 4m of hardplastic tube FH 5/3 PA and junctions to connect the test coil with the ADW and the sensing tube. Length: 10 m stainless steel 14 Securiton Product Catalogue 2016 ADW535

182 3.3. Teflon parts Sensor tube for applications in very corrosive and aggressive environments C (when used at more than 100 C, metal pipe clamps and brass screw-junction pieces must be used; if more than 180 C the screw-junction pieces must be outside of the monitored area ). When using Teflon sensing tubes, only classes A1l to Bl are possible according to EN Sensing tube teflon 6/4mm TU 6/4 PTFE 25 Tube to create the sensor part. (reel 25m). When used together with metal junctions, an according stiffener sleeve is necessary Diameter outside: Diameter inside: Length: 6 mm 4 mm 25 m teflon Sensing tube teflon 6/4mm TU 6/4 PTFE 100 Tube to create the sensor part. When used together with metal junctions, an according stiffener sleeve is necessary. (reel 100m) Diameter outside: Diameter inside: Length: 6 mm 4 mm 100 m teflon Adapter ADW-TU 6/4 PTFE AD ADW TU 6/4 For the connection of a Teflon sensor tube with the ADW detection unit. Including 1 stiffener sleeve SS 4 CuZn brass Stiffener sleeve for TU 6/4 PTFE SS 4 CuZn Stiffener sleeve for TU 6/4 PTFE brass Securiton Product Catalogue 2016 ADW535 15

183 Screw junction straight PVDF for TU 6/4 PTFE SJ 6/4 PVDF Screw junction straight PVDF for TU 6/4 PTFE For pipe diameter: 6 mm polyvinylidene fluoride End plug PVDF for SJ 6/4 PVDF EP 6/4 PVDF End plug for SJ 6/4 PVDF polyvinylidene fluoride T-Junction PVDF for TU 6/4 PTFE TJ 6/4 PVDF T-Junction for TU 6/4 PTFE polyvinylidene fluoride Screw Junction straight brass for TU 6/4 PTFE SJ 6/4 CuZn Screw junction straight CuZn for TU 6/4 PTFE. When used as end piece, 1 EP 6/4 CuZn and 1 SS 4 CuZn is necessary For pipe diameter: 6 mm brass End plug brass for SJ 6/4 CuZn EP 6/4 CuZn End plug for SJ 6/4 CuZn brass Reduction compression ferrule for SJ 6/4 CuZn-FH 5/3 PA RE 6-5 CuZn Reduction compression ferrule for FH 5/3 PA. To be used togheter with SJ 6/4 CuZn or TJ 6/4 CuZn brass T-Junction brass for TU 6/4 PTFE TJ 6/4 CuZn T-Junction for TU 6/4 PTFE brass 16 Securiton Product Catalogue 2016 ADW535

184 3.4. Polyamide parts Flexible Hose Polyamide 5/3mm FH 5/3 PA Flexible Hose to connect the ADW detection unit with the sensor part (Cu, St, PTFE) of the sensing tube. (Price per m). To be used together with stiffener sleeve SS 3 CuZn or SS 3 St Diameter outside: Diameter inside: Length: 5 mm 3 mm 1 m polyamide Stiffener sleeve brass for FH 5/3 PA SS 3 CuZn Stiffener sleeve for FH 5/3 PA brass Stiffener sleeve stainless steel for FH 5/3 PA SS 3 St Stiffener sleeve for FH 5/3 PA stainless steel Securiton Product Catalogue 2016 ADW535 17

185 4. Installation material Pipe Clamp PC 5/6 PP To mount the sensing tube. (delivery unit 1 pc) For pipe diameter: 5 mm polypropylen Pipe clamp PC 5/6 PA To mount the sensing tube. (delivery unit 100 pcs) For pipe diameter: 5 mm polyamide Pipe clamp PC 5/6 St To mount the sensing tube. (delivery unit 10 pcs) For pipe diameter: 5 mm stainless steel Pipe clamp PC 5/6 CuZn To mount the sensing tube. (delivery unit 10 pcs) For pipe diameter: 5 mm brass Double Pipe clamp PC 5/6 StG-2 To mount the sensing tube. (delivery unit 10 pcs) For pipe diameter: 5 mm brass ADW Sensing tube cleaning and maintenance set ACMS 535 ADW Sensing tube cleaning and maintenance set Securiton Product Catalogue 2016 ADW535

186 5. Accessories for Ex-Zones SensTube Teflon 6/4mm Ex TU 6/4 PTFE / Ex Tube to create the sensor part for Ex applications. (price per 100 m) Diameter outside: Diameter inside: Length: Explosion group: 6 mm 4 mm 100 m IIA Teflon Grounding Clamp GC 5/6 Ex Grounding Clamp To ground the sensing tube in Ex-zone applications brass External Temperature Sensor for EX-zones 1/2/21/22, max. 400 C ART Ex 400 C The ART 535 external temperature sensor is to be used in the following cases: - Applications compliant with EN 54-22, Class CI to GI - Always (for all response grades), as soon as the application temperature in the monitored area deviates more than 20 C from the temperature of the evaluation unit Diameter of sensor: 6 mm Ambient temperature: -50 C bis +400 C Length: 30 m Protection type: IP 65 Type of protection "e": Zone 1, 2 (II 2G Ex em T6) Zone 21, 22 (II 2D Ex mbd A21 IP65 T80 C stainless steel Securiton Product Catalogue 2016 ADW535 19

187 6. Spare Parts Main Board for ADW 535 LMB 35 Repair exchange for the ADW and Operating Voltage: Dimensions (H x W x D): Weight: 3.3 to 6 VDC 148x120x15mm 85 g Extension Board for ADW 535 LEB 35 Repair exchange for the second Sensor tube of ADW Dimensions (H x W x D): Weight: 75x54x35mm 39g Supervising Unit for ADW 535 LSU 35 The LSU 35 consists of a fully electronic differential pressure sensor, a pressure pump and a step motor SD-Card Industrial 2GB Lithium battery M20 Cable Screw Union SD-Industrial SD memory card (industrial) 2GB for on-board (LMB 35) use in ADW 535. BR2032 Replacement battery for LMB 35 M20 Cable screw union for ADW M25 Cable Screw Union M25 Cable screw union for ADW Securiton Product Catalogue 2016 ADW535

188 7. Product Type Index A ACMS AD ADW TU 6/ ADW 535 DCU... 8 ADW ADW 535-1HDx... 6 ADW ADW 535-2HDx... 6 ART ART Ex 400 C B BR D D&PL_ADW-Conf... 9 D&PL_ADW-Conf_N... 9 D&UL_ADW-Conf... 9 D&UL_ADW-Conf_N... 9 E EP 5/4 CuZN EP 5/4 St EP 6/4 CuZn EP 6/4 PVDF F FH 5/3 PA G GC 5/6 Ex H HealCalc... 9 L LEB LMB LSU M M M P PC 5/6 CuZn PC 5/6 PA PC 5/6 PP PC 5/6 St PC 5/6 StG PL_ADW-Conf... 9 PL_ADW-Conf_N... 9 PS TU 5/4 St R RE 6-5 CuZn RIM S SC 5/4 Cu SC 5/4 St SD-Industrial SIM SJ 5/4 CuZN SJ 5/4 St SJ 6/4 CuZn SJ 6/4 PVDF SMM SS 3 CuZn SS 4 CuZn SS 4/3 St T TC 5/4 Cu TC 5/4 St TJ 5/4 CuZn TJ 5/4 St TJ 6/4 CuZn TJ 6/4 PVDF TU 5/4 Cu TU 5/4 Cu TU 5/4 St TU 6/4 PTFE / Ex TU 6/4 PTFE TU 6/4 PTFE U UL_ADW-Conf... 9 UL_ADW-Conf_N... 9 X XLM Securiton Product Catalogue 2016 ADW535 21

189 22 Securiton Product Catalogue 2016 ADW535

190 SecuriSens d-list Product Catalogue 2016

191 Content 1. Processor Units Demo and Test Equipment Cable d-list Single Sensor d-list Accessories d-list ATEX components d-list Spare Parts d-list Services Product Type Index Securiton Product Catalogue 2016 d-list

192 Introduction SecuriSens d-list heat detectors, where all other detectors reach their limits. Dust, heat, smoke, exhaust fumes and other interference factors have a significant impact on detecting fires when using conventional fire detectors. However, it is exactly under such difficult conditions that the fire risk is so great and it is vital to ensure quick and reliable detection such as in tunnels, industrial facilities, power plants and car parks. With the SecuriSens d-list line-type heat detectors, Securiton provides systems that can enable the rapid localisation of a fire even when used in harsh, aggressive environments. Safety in industrial facilities the SecuriSens d-list. The SecuriSens d-list line-type heat detector with SEC 15 sensor cable is ideally suited to applications with small monitoring areas. Two sensor cables with a maximum length of 250 metres each can be connected to the SCU 800 (sensor control unit) and put into operation at the touch of a button and all without special aids or advance knowledge of the system. The monitoring system with a maximum of two sets of 99 sensors can be universally integrated in fire alarm systems and also offers mobile application possibilities. Several SCU 800 units can be networked easily for monitoring larger areas. The d-list system can also be expanded with individual temperature sensors in metal housings for monitoring critical areas such as drive units on conveyor belts and escalators, among others. Outstanding flexibility because every object needs individual protection. The spacing between sensors can be freely selected, and it is even possible to combine different sensor spacing distances. You can see where the sensors are located according to the markings on the outer sheathing of the sensor cable. Another highlight (and one that is absolutely unique on the market) is the problem-free branching of the cable harnesses. External individual sensors in metal housings are available for special applications and can be easily connected to the SecuriSens d-list system. Different sensor cable areas can be connected together with one signal cable. Product The descriptions and technical data included in this catalogue are up-to-date at the time of release. We reserve the right to make alterations to them, particularly where justified by technological advancements. The illustrated products may also differ visually from the products supplied as a result of continuous further development of products. The layout of this catalogue is subject to copyright. The copying or reuse of text, illustrations and photos in any media (e.g. print, CD-ROM, Internet, etc.) contained within this catalogue - also in an abridged form - is only allowed with our explicit written permission. We assume no liability for typographic errors and obvious mistakes. Please quote the relevant item numbers when making enquiries or placing an order. Delivery conditions are regulated in the General Terms and Conditions of Securiton AG for Export Deliveries Securiton Product Catalogue 2016 d-list 3

193 How to read the catalogue Example of a typical entry for an item Type & Article Number Please quote this number when making an enquiry or ordering Cable clamp CLIC 15 CLIC Cable clamp for SEC pieces per packaging unit Polyamid, halogen free Weight: 5 g Colour: Grey RAL 7035 Illustration Description and technical data 4 Securiton Product Catalogue 2016 d-list

194 1. Processor Units Sensor Control Unit SCU SCU 800/ The sensor control unit SCU 800 is the central supervisory element for the d-list-system. It provides up to two d-list sensor cables with power, performs the cyclic addressing of the connected sensors every 10 seconds, acquires the temperature values measured by each sensor and evaluates the data with reference to various criteria. A fire alarm is generated if either a given maximum threshold is exceeded, or if an increase in temperature takes place within a certain time (differential evaluation). The two thresholds (set-points) can be set individually for each of the attached sensor cables. The measurement resolution of 0,1 gives the system a high sensitivity. The tried and tested algorithms used in the evaluation eliminate false alarms due to natural temperature variations. Switching voltage: 48 VDC / 32 VAC max. Switching current: 250 ma max. Input: 5 VDC reset input, galvanically isolated Continuous operating temperature: -10 C C Power supply: VDC Power consumption: 1 29 VDC Dimensions: 260 x 150 x 90 mm Housing material: aluminium Weight: SCU800-03: 1,9 Kg SCU800/16: 2,3 Kg Outputs: SCU800-03: 3 relays (1 alarm relay per cable, 1 fault relay) SCU800/16: 16 zonal relays Spare Parts: Description Type Art. No. Accessories cable glands SCU 800 Acc Accessories blind plugs SCU 800 Plug Accessories connectors SCU 800 Con Securiton Product Catalogue 2016 d-list 5

195 LISTcontroller Master Lcon Master Central control and display unit as master for d-list sensor cable systems, with alphanumeric LCD display and operation buttons, a potential-free change-over contact for buzzer fault/alarm each, operating voltage: 24 VDC; mounted in 19" unit rack, for cabinet mounting: Operating voltage: Operating temperature: Power supply: Current draw at 24 V DC: Power consumption: Relay output: Switching Voltage: Switching current: Input: Dimensions(WxHxD): Resembling a 19 : Case material: Weight: 24 VDC -5 C C, 9,5 V 36 V DC 175 ma (Normal) 212 ma (Alarm) Max. 5 W 1 Relay each for alarm pre-alarm and frost-alarm 1 Relay for fault (= active without power) 48 V DC / 32 V AC max. 250 ma max. (resistive load) 1 x external reset (5 V 36 V DC) 482,6 x 43,6 x 315,5 mm 1U case and 400 mm depth Aluminium 2,6 kg Remote Display Unit RDU 316 Alphanumerical remote display, coloured background, 3 lines, 16 characters each, with menu-keys and common LEDs; RS 485 interface to communicate with a maximum of 31 SCU 800 control units; allow the identification of a sensor number in case of alarm - stores all messages incl. date & time - indicates messages with unit and sensor number, alarm zone - test mode, which gives the status of the sensors - clear text display in various languages Current consumption 24V: Power supply: 40 ma (Normal) 100 ma (Alarm) V DC Protection class: IP 66 Ambient temperature: 0 C +60 C Dimensions (HxWxD): 110 x 140 x 60 mm Case material: glass-fiber reinforced polycarbonate 6 Securiton Product Catalogue 2016 d-list

196 1.1. Demo and Test Equipment d-list Demo case d-list DCU Demo case, fully assembled and programmed with evaluation unit SCU 800, remote display RDU 316, sensor cable SEC 15 section with one sensor, two external sensors ESD, 30 internal sensors, Bluetooth adapter, power supply V AC Weight: Dimensions (HxWxD): 9,5 Kg 545 x 230 x 405 mm Securiton Product Catalogue 2016 d-list 7

197 2. Cable d-list Sensor Cable SEC 15/01 sensor distance 1m SEC 15/02 sensor distance 2m SEC 15/03 sensor distance 3m SEC 15/04 sensor distance 4m SEC 15/05 sensor distance 5m The cable is able to measure temperatures from -40 C to +85 C (for short periods +120 C) with a resolution of 0,1 Celsius. Cable structure: - Hybrid circuits mounted on a 2 core flat flexible cable - Filling material with strain relief, which secures the cable in case of fire - Aluminium shield - Halogenfree cable sheath; flame retardent and noncorrosive, with sensor marking Operating temperature: -40 C +85 C up to +120 C short term Measuring temperature: -55 C +120 C Cable diameter: Typ. 15 mm Flat conductor resistance: Typ. 85 Ω / km (single conductor) Sheath material: HM4 mixture, halogen free, flame retardant Weight: Typ. 0,45 kg / m Colour: Grey 8 Securiton Product Catalogue 2016 d-list

198 3. Single Sensor d-list External Sensor rectangular ESD-A5-EL-01 1m ESD-A5-EL-05 5m ESD-A5-EL-10 10m Stainless steel sensor A5 for use with the d-list-system, whereby all sensors are connected in parallel via standard terminals. These sensors can be used together with SEC15 sensor cable and the control unit SCU800. Design: Measuring range: Sensor material: rectangular 8 mm -55 C C Stainless steel External Sensor round ESD-A5-RL-01 1m ESD-A5-RL-05 5m ESD-A5-RL-10 10m Stainless steel sensor A5 for use with the d-list-system, whereby all sensors are connected in parallel via standard terminals. These sensors can be used together with SEC15 sensor cable and the control unit SCU800. Design: Measuring range: Sensor material: round 8 mm -55 C C Stainless steel Securiton Product Catalogue 2016 d-list 9

199 4. Accessories d-list Cable clamp CLIC 15 CLIC 15 Cable clamp for SEC pieces per packaging unit Polyamid, halogen free Weight: 5 g Colour: Grey RAL 7035 Fixing clamp MDC MDC Pipe clamp for SEC 15 with locking clip Weight: Stainless steel 10 g Cable clamp MDJ MDJ Stainless steel clamp Weight: Stainless steel 100 g Fixing element for messenger cables FEMC 270 Cable fastener for line mounting Stainless steel cable tie FECT 201-A4 Protection for MDJ clamp and line mounting fastener in the event of a fire Connection Cable CC 15 LISTEC supply cable 1x2x0.8, shielded, JE-H(ST)H E30, for an SEC 15 sensor cable. If it is not possible to connect the sensor cable directly to the sensor control unit SCU800, the connection cable CC15 can connect sensor control unit and sensor cable via the connection box Operating temperature: Sheath material: Colour: -30 C C HM2 compound, flame retardant red 10 Securiton Product Catalogue 2016 d-list

200 Connection Box CBO 5-SEC Connection unit for one or two temperature sensor cable SEC15 including an universal connection module UCM. If it is not possible to connect the sensor cable directly to the sensor control unit SCU800, the connection cable CC15 can connect sensor control unit and sensor cable via the connection box. In the box the connection cable and the sensor cable are linked together via the connection module UCM. If short transmission lines are linked the universal connection module has the possibility to activate adaptation resistors. Operating temperature: Resistance to impact: -35 C C (short period +80 C) IK 08 according DIN 5012 / VDE 0470 part 100 glass-fibre reinforced, polycarbonat Protection class: IP 66 Dimensions:(LxWxH): 130 x 130 x 75 mm Spare Parts: Description Type Art. No. Accessory Bag CBO 5-SEC Acc Connection Box CBO 5-ESD-T Connection unit for up to eight external sensors ESD or four single sensors and one LIST-cable SEC15. The external sensors can be connected to the SEC15 sensor cable bus via the connection box. It is possible to connect up to eight single sensors to the bus or four sensors and a sensor cable. Every connection has an adaption resistance. This can be activated, if needed, for example for short adaptation resistors. Operating temperature: Resistance to impact: -35 C C (short period +80 C) IK 08 according DIN 5012 / VDE 0470 part 100 glass-fibre reinforced, polycarbonat Protection class: IP 66 Dimensions:(LxWxH): 130 x 130 x 75 mm Spare Parts: Description Type Art. No. Accessory Bag CBO 5-ESD-T Acc Securiton Product Catalogue 2016 d-list 11

201 Fitted cable Fitted cable Connector SEC 15 fit box Sensor cable with termination cap, CLB2 and shield connector. SEC 15 fit con Sensor cable pre-fabrication with plug, 3-pin and termination cap. SECcon 15-Cf Coupling with socket, 3-pin Optical Input Module OIM 15 The Optical Input Module OIM15 provides an interface from external switches to the d-list-system. It is possible to record and evaluate input information at the same time in one measurement cycle. Each OIM-Module has 4 inputs to use. These inputs are isolated via optical couplers from the SEC15-system. An external voltage is necessary to activate the optical couplers. Please order firmware ES8D1 OIM with it Inputs: Operating voltage: Switching voltage: Operating temperature: Dimensions(LxWxH): Weight: Installation: Electrical switches on internal terminal blocks, galvanically isolated via optical couplers 24V DC 18V V DC, < 18V with different line resistor 0 C C 68mm x 82mm x 40mm kg rail mounted Firmware SW-PROM ES8D1 OIM ES8D1 OIM This Firmware must be ordered to operate the OIM Configuration software Dongle (USB) for LISTp800 LISTp800 The LIST p800 configuration software was specially developed for the operation and programming of the SecuriSens d-list system. CM-USB KEYRING Registration Dongle for LIST p Securiton Product Catalogue 2016 d-list

202 USB / RS 485 converter USB-RS485 USB / RS 485 cable for connection between SCU 800 and PC Connection Cable VK232-S8-PC-03 RS 232 cable for connection between SCU 800 and PC Crimping tool CLCT LIST crimping tool for 2-and 4-core flat cable connectors LIST cable cutter Cutter SEC Cable scissors for SEC sensor cable Service case SC 15/20 Service case with tool for repair and connection of sensor cable. Content: Article Tool case 1 Manual SCU800/SEC 15 1 LIST-Crimping tool, adjusted 1 Cable cutter 1 Cable knife 1 Cable-stripping tool 1 Selection of 6 screwdrivers 1 Size 3 electronic screwdriver 1 Electronic side cutter 1 Side cutter 1 Multigrip pliers 1 Combination pliers 1 Clincher male CLS2 15 Clincher female CLB2 15 Clincher strain relief CLVS 15 Shield connector SEC End cap END 15 2 Clamp Clic CCM modul SEC 150-A 1 UCM-SEC 1 Sleeve SEC 15 2 Isolating tape 1 Tape to vulcanize 1 Quantity Securiton Product Catalogue 2016 d-list 13

203 5. ATEX components d-list Ex-proof enclosure CAB 800-ex Ex housing, pre-mounted with mounting plate, terminal block, earthing rail and screw-junction pieces, for holding a SCU cable terminal processor (only housing) ATEX Marker for sensor cable ATEX Marker for external sensor External sensor Ex proof connection box Label SEC 15 Atex Identification and conformity certificate for SEC 15 sensor cable for use in zone 2 and 22. Label ESD Atex Identification and conformity certificate for ESD individual sensor for use in zone 2 and ESD-Atex-A4-RL-01 1m ESD-Atex-A4-RL-05 5m ESD-Atex-A4-RL-10 10m External sensor round stainless steel sensor in A4 to connected to the d-list Line Type Heat Detector via suitably certified connection boxes. Design: Round Thread: M 20 x 1,5 Ambient temperature Ta: -20 C C Sensor barrel: Stainless steel A4 ( WSt ) Cable sheath: FEP Approvals: EX II 1/2 G Ex d IIC T6, T5, T4 EX II 1/2 D Ex td A20/21 IP65, 85 C, 100 C, 135 C CBO 05-Ex Connection box for sensor cable SEC 15 and external sensors ESD in potentially explosive atmospheres (Zone 2 and 22). Spare Parts: Description Type Art. No. Accessory Bag CBO 5-Ex Acc Securiton Product Catalogue 2016 d-list

204 6. Spare Parts d-list Main board SCI 800 LP Main board for SCU / SCU 800/16 For repair only LED-indication board IB 800 LP LED-board with group indication for SCU 800 For repair only Relay Card REL 800/16 LP Relay card with 16 potential-free change-over contacts for SCU Housing SCU 800 Case End caps pre-mounted, incl. front foil, housing covering strips & cover holder; with Securiton front foil Shield Connector SCON 15/0 (with ring connector) SCON 15/1 (with Pin) Shield connectors for connecting sensor cables. Flat Cable Connector CLB 2 Ribbon cable crimping connector, 2-core, socket 100 pieces per packaging unit Clincher Strain Relief CLVP For locking a CLB clincher with pin plug 100 pieces per packaging unit End device END End cap for sensor cable SEC Securiton Product Catalogue 2016 d-list 15

205 Repair-set N15 Repair Shrink sleeve with ribbon cable connection, shield connector, plug and socket, and sealing material. For connecting two SEC 15 cables Universal connection module Universal connection module UCM-ESD Connection module for up to 8 External sensors ESD respectively, 4 external sensors and one sensor cable SEC15 (CBO 5-ESD; CBO 5-ESD-T) UCM-SEC Connection module for up to two sensor cabes SEC 15(CBO 5-SEC) Securiton Product Catalogue 2016 d-list

206 7. Services SecuriSens LIST Commissioning Europe Commission EU Commissioning support fee for projects within Europe. SecuriSens LIST Commissioning Overseas Commission OvS Commissioning support fee for projects at Overseas Securiton Product Catalogue 2016 d-list 17

207 8. Product Type Index C CAB 800-ex CBO 05-Ex CBO 5-ESD-T CBO 5-ESD-T Acc CBO 5-Ex Acc CBO 5-SEC CBO 5-SEC Acc CC CLB CLCT CLIC CLVP CM-USB KEYRING Commision EU Commision OvS Cutter SEC D d-list DCU... 7 E END ES8D1 OIM ESD-A5-EL ESD-A5-EL ESD-A5-EL ESD-A5-RL ESD-A5-RL ESD-A5-RL ESD-Atex-A4-RL ESD-Atex-A4-RL ESD-Atex-A4-RL F FECT 201-A FEMC I IB 800 LP L Label ESD Atex Label SEC 15 Atex Lcon Master...6 LISTp M MDC MDJ N N15 Repair O OIM R RDU REL 800/16 LP S SC SCI 800 LP SCON 15/ SCON 15/ SCU 800 Acc... 5 SCU 800 Case SCU 800 Con... 5 SCU 800 Plug... 5 SCU 800/ SCU SEC 15 fit box SEC 15 fit con SEC 15/ SEC 15/ SEC 15/ SEC 15/ SEC 15/ SECcon 15-Cf U UCM-ESD UCM-SEC USB-RS V VK232-S8-PC Securiton Product Catalogue 2016 d-list

208 Securiton Product Catalogue 2016 d-list 19

209 20 Securiton Product Catalogue 2016 d-list

210 SecuriSens LIST Product Catalogue 2016

211 Content 1. Processor Units Cable Accessories List Spare Parts Services Product Type Index Securiton Product Catalogue 2016 LIST

212 Introduction SecuriSens LIST heat detectors, where all other detectors reach their limits. Dust, heat, smoke, exhaust fumes and other interference factors have a significant impact on detecting fires when using conventional fire detectors. However, it is exactly under such difficult conditions that the fire risk is so great and it is vital to ensure quick and reliable detection such as in tunnels, industrial facilities, power plants and car parks. With the SecuriSens LIST line-type heat detectors, Securiton provides systems that can enable the rapid localisation of a fire even when used in harsh, aggressive environments. Safety in tunnels the SecuriSens LIST. The SecuriSens LIST SEC 20 line-type heat detector is the ideal fire detector for use in tunnels. It consists of the SEC 20 sensor cable and the LISTcontroller. The system offers reliable monitoring of sections of up to 3,200 metres in length, or up to 350 sensors. Up to two sensor cables can be connected to one LISTcontroller (stub, loop or in redundant operation with a second LISTcontroller). The detection and alarm thresholds can be configured for a maximum of 254 different alarm sections. Every ten seconds, the system measures the temperature on the sensors and compares this with the programmed threshold values. Outstanding flexibility because every object needs individual protection. The spacing between sensors can be freely selected, and it is even possible to combine different sensor spacing distances. You can see where the sensors are located according to the markings on the outer sheathing of the sensor cable. Another highlight (and one that is absolutely unique on the market) is the problem-free branching of the cable harnesses. External individual sensors in metal housings are available for special applications and can be easily connected to the SecuriSens LIST system. Different sensor cable areas can be connected together with one signal cable. Product The descriptions and technical data included in this catalogue are up-to-date at the time of release. We reserve the right to make alterations to them, particularly where justified by technological advancements. The illustrated products may also differ visually from the products supplied as a result of continuous further development of products. The layout of this catalogue is subject to copyright. The copying or reuse of text, illustrations and photos in any media (e.g. print, CD-ROM, Internet, etc.) contained within this catalogue - also in an abridged form - is only allowed with our explicit written permission. We assume no liability for typographic errors and obvious mistakes. Please quote the relevant item numbers when making enquiries or placing an order. Delivery conditions are regulated in the General Terms and Conditions of Securiton AG for Export Deliveries Securiton Product Catalogue 2016 LIST 3

213 How to read the catalogue Example of a typical entry for an item Type & Article Number Please quote this number when making an enquiry or ordering Cable clamp CLIC Cable clamp for SEC pieces per packaging unit. Polyamid, halogen free Weight: 5 g Colour: Grey RAL 7035 Illustration Description and technical data 4 Securiton Product Catalogue 2016 LIST

214 1. Processor Units Control and Evaluation Unit Lcon SEC (Standard) Cable terminal unit with a sensor cable connection. The LIST controller is the central control unit and cable terminal processor for the SEC 20 sensor cable. With an ARM9 embedded processor and two peripheral processors it provides the evaluation and signaling. Detection and alarm threshold values can be differently programmed for up to 254 alarm sections. Used in pairs and enhanced with RDT function, LIST controllers LB guarantee full cable and device redundancy. Scope of delivery: 1x connecting cablevk24-s4-kl-03 1x connecting cablevki/o-s4-kl-03 1x connecting cablevksec-s4-kl-03 Contact voltage: Supply voltage: Contact current: Input: Ambient temperature: Current draw at 24 V DC: 48 V DC / 32 V AC max 9,5 36 V DC 250 ma max. (resistive load) 1 x external reset (5 V 36 V DC) -5 C +70 C, Normal 175 ma Alarm 212 ma Max. 5 W Power consumption: Relay outputs: 1 Relay for fault (= active without power) 1 Relay each for alarm, pre-alarm and frost-alarm Dimensions (HxWxD): 482,6 x 43,6 x 313,5 Aluminium Weight: Evaluation: 2,6 kg heat Securiton Product Catalogue 2016 LIST 5

215 Control and Evaluation Unit Lcon LB (with loop function) RDT-Function for LIST controller Cable terminal unit with a sensor cable connection. The LIST controller is the central control unit and cable terminal processor for the SEC 20 sensor cable. With an ARM9 embedded processor and two peripheral processors it provides the evaluation and signalling. Detection and alarm threshold values can be differently programmed for up to 254 alarm sections. Used in pairs and enhanced with RDT function, LIST controllers LB guarantee full cable and device redundancy. Scope of delivery: 1x connecting cablevk24-s4-kl-03 1x connecting cablevki/o-s4-kl-03 2x connecting cablevksec-s4-kl-03 Contact voltage: Supply voltage: Contact current: Input: Ambient temperature: Current draw at 24 V DC: 48 V DC / 32 V AC max 9,5 36 V DC 250 ma max. (resistive load) 1 x external reset (5 V 36 V DC) -5 C +70 C, Normal 175 ma Alarm 212 ma Max. 5 W Power consumption: Relay outputs: 1 Relay for fault (= active without power) 1 Relay each for alarm, pre-alarm and frost-alarm Dimensions (HxWxD): 482,6 x 43,6 x 313,5 Aluminium Weight: Evaluation: 2,6 kg heat Lcon RDT Redundancy control: If a fully redundant system is required, two LIST controllers LB always work together in pairs. Both communicate with each other, both have the complete information, and if necessary take on the tasks of the other one (cable break, device failure). This function must be ordered separately I/P-Interface und Protocol Lcon I/P Modbus (Modbus TCP) Lcon I/P IEC (IEC ) Software function for LIST controller. 6 Securiton Product Catalogue 2016 LIST

216 Relay Module RELMOD Relay module with 16 relays and 8 inputs. - Very low energy consumption - Coding Switch for module address (1 16) - Inputs to remotely activate revision-mode and to initiate alarm simulations - Inputs for external alarm- and fault-handling signals - Input to trigger timer-controlled deactivation of differential temperature monitoring Contact voltage: 48 V DC / 32 V AC Contact current: 250 ma max. (resistive load) Supply voltage: V DC Current draw at 24 V DC: 56 ma (Normal) 105 ma (Alarm) Power consumption: Max. 2,4 W Relay outputs: 16 x toggle contacts for alarm, pre-alarm, fault and frost-alarm (loop resistors may be inserted for closed-circuit monitoring Optocoupler input: 8x electrically isolated, 5 28 V DC signals Ambient temperature: 0 C +70 C Dimensions (HxWxD): 167 x 113,3 x 66,2 mm Case material: Aluminium Weight: 0,61 kg Remote Display Unit RDU 316 Alphanumerical remote display, coloured background, 3 lines, 16 characters each, with menu-keys and common LEDs; RS 485 interface to communicate with a maximum of 31 SCU 800 control units; allow the identification of a sensor number in case of alarm - stores all messages incl. date & time - indicates messages with unit and sensor number, alarm zone - test mode, which gives the status of the sensors - clear text display in various languages Current consumption 24V: Power supply: 40 ma (Normal) 100 ma (Alarm) V DC Protection class: IP 66 Ambient temperature: 0 C +60 C Dimensions (HxWxD): 110 x 140 x 60 mm Case material: glass-fiber reinforced polycarbonate Securiton Product Catalogue 2016 LIST 7

217 2. Cable Cables List SEC 20/02 (Sensor spacing 2m) SEC 20/04 (Sensor spacing 4m) SEC 20/05 (Sensor spacing 5m) SEC 20/08 (Sensor spacing 8m) SEC 20/10 (Sensor spacing 10m) "Can be used in a temperature range of -40 C to +120 C (briefly +200 C) and detects temperatures with a resolution of 0.1 C. Cable terminal processor and sensors communicate bi-directionally. The cable sheathing is marked with the sensor designations. Cable design: - Ribbon cable conductor, 4-core with mounted hybrid switches - Filling material with strain relief (for cable protection in the event of a fire) - Integrated aluminium shield - Outer sheath halogen-free and flame resistant Operating temperature: -40 C +120 C up to +200 C short term Measuring temperature: -40 C +200 C Cable diameter: Typ. 18 mm Flat conductor resistance: Typ. 85 Ω / km (single conductor) Sheath material: HM4 mixture, halogen free, flame retardan Weight: Typ. 0,45 kg / m Sheath colour: Grey 8 Securiton Product Catalogue 2016 LIST

218 3. Accessories List Cable clamp Mounting device Mounting device CLIC 17 Cable clamp plastic for SEC pieces per packaging unit Polyamid, halogen free Weight: 5 g Colour: Grey RAL 7035 MDP 20 Cable clamp CLIC 17 with dowel and stainless steel screw. 100 pieces per packaging unit Colour: Grey RAL 7035 MDJ 40 Stainless steel clip, grade , with stainless steel dowel and cable fastener Weight: Stainless steel 100 g Connection Box CBO 20/0 (for two SEC20) Connection box between two sensor cables Protection class: IP66 glass-fiber reinforced polycarbonate Colour: RAL 7032 grey Operating temperature: -30 C C Weight: 1.6 Kg Dimensions (HxWxD): 244x164x101 mm Spare parts: Description Type Art. No. Accessory Bag CBO 20/0 Acc Screw for CBO CBO 20 Screw Securiton Product Catalogue 2016 LIST 9

219 Connection Box CBO 20/1 (to link a SEC20 with a CC 20) CBO 20/3 (to link up to three SEC with up to two CC20) Box for the connection of sensor cable SEC 20, incl. connection module CCM with over-voltage-protection. Connection Cable LIST cable tester Protection class: IP66 glass-fiber reinforced polycarbonate Colour: RAL 7032 grey Operating temperature: -30 C C Weight: 1.6 Kg Dimensions (HxWxD): 244x164x101 mm Spare parts: Description Type Art. No. Accessory Bag CBO 20/1 Acc Accessory Bag CBO 20/3 Acc Accessory Bag CBO 20/3 Acc CCM Screw for CBO CBO 20 Screw CC 20 LISTEC supply cable 2x2x0.8, shielded, JE-H(ST)H E30, for an SEC 20 sensor cable If it is not possible to connect the sensor cable directly to the sensor control unit, the connection cable CC 20 can connect sensor control unit and sensor cable via the connection box. Operating temperature: -30 C +70 C Sheath material: HM2 compound, flame retardant Colour: red LCT 20 Sensor and cable tester for LIST sensor cable SEC 20; for fast testing of LIST sensor cables immediately after installation or temporary storage. - USB connection - Battery operation - Aluminium housing with shoulder straps - Power supply unit Sensor address range: AC power adapter: Input: V AC 50/60 Hz 0.5 A Output: 15 V DC, 1200 ma Operating temperature: -10 C +60 C Dimensions (HxWxD): 206,0 x 168,0 x 36,0 mm Case material: Aluminium Weight: 1,1 kg (including shoulder-strap) Securiton Product Catalogue 2016 LIST

220 Power Supply PS 2402 (2A) PS 2408 (8A) Uninterruptable power supply, VdS approved; in wall mounted cabinet or as 19" sub-rack (6 height units) available Fibre optic converter Mains voltage: 230 V AC +10/-20% Mains frequency: Hz Output voltage: Typ. 27,6 V DC at 20 C Output current: 2A version Max. 2,3 A 8A version Max. 8,4 A Operating temperature: -5 C +50 C Relative humidity: Max. 95% at 40 C (No condensation) Dimensions (HxWxD): 230,0 x 150,0 x 54,0 mm (power supply module only) 478,0 x 266,0 x 63,0 mm (mounted on 19 front-panel, w = 19, h = 6U) Weight: 0,5 kg power supply module only 2,0 kg mounted on 19 front-panel Front-panel colour: RAL 9002, grey-white FOC 485 Interface converter for RS 485 to fibre optic, single and multi. Operating voltage: VDC (typ. 24 VDC) Current consumption: 140 ma at 24 VDC, 110 ma at 32 VDC Power consumption: < 3,5 W Signal type: RS 485 Operating temperature: -25 ºC to +70 ºC Relative humidity: <95% (non-condensing) Dimensions (WxHxD): 35 x 163 x 119 mm Case material: plastics Weight: 215 g Protection class: IP Securiton Product Catalogue 2016 LIST 11

221 Optical fibre converter FOC LAN-multi (multi-mode) LAN-single (single-mode) Interface converter for LAN to fibre optic Operating voltage: 24 V DC ( 18-32V) Current consumption at 24 V: 315 ma Operating temperature: 0 C.+ 60 C Storage / transport temperature: -40 C C Relative humidity: 10% - 95% (non-condensing) Dimensions: 71 mm x 131 mm x 111 mm Weight: 0,4 kg Housing: Plastic case Protection class: IP20 Wall mounted cabinet CAB 19/12 (12HE) CAB 19/18 (18 HE) " wall cabinet, completely wired, incl. terminals. For holding a LIST controller, two relay modules, PS 24xx power supply unit and a fibre optic converter Spare parts: Crimping tool Description Type Art. No. Accessory Bag CAB 19 Acc Wall mounting holder for CAB 19/x CAB WallHold CLCT LIST crimping tool for 2-and 4-core flat cable connectors LIST cable cutter Cutter SEC Cable scissors for SEC sensor cable Securiton Product Catalogue 2016 LIST

222 Service case SC 15/20 Service case with tool for repair and connection of sensor cable Content: Article Tool case 1 Installation guidelines SEC 20 (60T157-0x) 1 Sensor cable repair (60T032) 1 LIST-Crimping tool, adjusted 1 Cable cutter 1 Cable knife 1 Cable-stripping knife 1 Selection of 6 screwdrivers 1 Size 3 electronic screwdriver 1 Electronic side cutter 1 Side cutter 1 Multigrip pliers 1 Combination pliers 1 Clincher male CLS4 15 Clincher female CLB4 15 Clincher strain relief CLVS 15 Shield connector SEC End cap END 20 2 Clamp Clic Top CCM modul SEC 20 1 Sleeve SEC 20 2 Isolating tape 1 Tape to vulcanize 1 Quantity Securiton Product Catalogue 2016 LIST 13

223 4. Spare Parts Connection Cable VKSEC-S4-KL-03 Pre-assembled connecting cable for connection to sensor cable Length: 3 m Connection Cable VK485-S4-MS-03 Pre-assembled connecting cable for RS 485 connection Length: 3 m Connection Cable VK232-S4-KL-03 Pre-assembled connecting cable for RS 232 connection Length: 3 m Connection Cable VKI/O-S4-KL-03 Pre-assembled connecting cable for control I/O connection Length: 3 m Connection Cable VK24-S4-KL-03 Pre-assembled connecting cable for power supply Length: 3 m Connection Cable VKLAN-S4-PC-03 Pre-assembled connecting cable for LAN connection Length: 3 m Line monitoring pcb RELMOD-R To hold the loop resistors Securiton Product Catalogue 2016 LIST

224 Fuse for RELMOD RELMOD-F Fuse for RELMOD, 1 A, 250 V, fast Shield Connector Flat cable connector Clincher Strain Relief End device Repair-set Connection Module Drill SDS 3L Setting tool SCON 20/1 (one sensor cable) SCON 20/2 (two sensor cables) For connecting sensor cables CLB 4 (socket) CLS 4 (plug) Ribbon cable crimping connector, 4-core. 100 pieces per packaging unit. CLVP For locking a CLB clincher with pin plug. 100 pieces per packaging unit END End cap for sensor cable SEC 15 N20 Repair Shrink sleeve with ribbon cable connection, shield connector, plug and socket, and sealing material. For connecting two SEC 20 cables CCM CCM 3000_D (with over-voltage protection) Connection module for one or two sensor cables SEC 20 as junction between sensor cable and connection cable CC 20. SDS 3L Drill for setting the MDJ 40 dowels SWM-SM 50 Setting tool for MDJ 40 dowel (for hammer drill) Setting tool SWM-H Setting tool for MDJ 40 dowel (for manual mounting) Securiton Product Catalogue 2016 LIST 15

225 5. Services SecuriSens LIST Commissioning Europe Commission EU Commissioning support fee for projects within Europe. SecuriSens LIST Commissioning Overseas Commission OvS Commissioning support fee for projects at Overseas Securiton Product Catalogue 2016 LIST

226 6. Product Type Index C CAB 19 Acc CAB 19/ CAB 19/ CAB WallHold CBO 20 Screw... 9, 10 CBO 20/ CBO 20/0 Acc... 9 CBO 20/ CBO 20/1 Acc CBO 20/ CBO 20/3 Acc CBO 20/3 Acc CCM CC CCM CCM 3000_D CLB CLCT CLIC CLS CLVP Cutter SEC E END F FOC L LAN-multi LAN-single Lcon I/P IEC... 6 Lcon I/P Modbus... 6 Lcon LB... 6 Lcon RDT... 6 Lcon SEC... 5 LCT M MDJ MDP N N20 Repair P PS PS R RDU RELMOD... 7 RELMOD-F RELMOD-R S SC SCON 20/ SCON 20/ SDS 3L SEC 20/ SEC 20/ SEC 20/ SEC 20/ SEC 20/ SWM-H SWM-SM V VK232-S4-KL VK24-S4-KL VK485-S4-KL VKI/O-S4-KL VKLAN-S4-PC VKSEC-S4-KL Securiton Product Catalogue 2016 LIST 17

227 18 Securiton Product Catalogue 2016 LIST

228 Genius Home Smoke Detector Product Catalogue 2016

229 Content 1. Smoke alarm device Radio module Accessories for smoke alarm devices Product Type Index Securiton Product Catalogue 2016 Genius Home Smoke Detector

230 Introduction Genius H with genuine alarm guarantee simply brilliant. Annually 70% of the victims of fire die at night. The cause: when we sleep we do not smell anything. When a fire breaks out, the deadly smoke spreads quickly throughout the entire house or flat and goes unnoticed. Smoke detectors such as the new Genius H warn you early and offer maximum protection. Genius Hx the next generation smoke detector Do you live or sleep on more than one floor? Have you finally decided to monitor your kitchen the number one source of fires with a smoke alarm device? Then Genius Hx is the right choice for you! In addition to the many features of the Genius H, the Genius Hx offers a host of other advantages, such as the variety of ways it can be used. Universal use The range of Genius Hx applications extends beyond the usual areas of use to include difficult environments, such as kitchens, passageways, frost-free cellars and attics. Genius Hx is also ideal for residential buildings and apartment buildings as well as for public facilities, for example schools, kindergartens, dormitories, special-care homes and day-care centres, community centres, and commercial settings such as apothecary shops, doctors' surgeries, offices, hotels and guest houses. Radio network Genius Hx can be optionally radio networked. The Basic and Pro radio modules are able to send an alarm signal over long distances in the event of a fire. Special highlight: even with its radio module the Genius Hx has a typical battery life of ten years thanks to its additional battery. General information The descriptions and technical specifications in this catalogue are current as of the date of publication. We reserve the right to make changes in the design and technical specifications. Due to on-going development, delivered products may differ visually from the products as pictured. The layout of this catalogue is copyright protected. Reproduction and re-use of text, illustrations and photos in all media (e.g. print, CD-ROM, Internet), including shortened forms are permitted only with our express written consent. We assume no liability for typographical errors and obvious mistakes. Please include the article numbers should you have any questions or wish to place an order. The delivery conditions are based on the General terms and conditions of Securiton AG Switzerland. Securiton Product Catalogue 2016 Genius Home Smoke Detector 3

231 How to read the catalogue Example of a typical entry for an item Basic radio network module FM BASIC Radio module for wirelessly networking multiple Genius Hx smoke alarm devices with each other for area-wide alarm signalling. - Repeater for alarm forwarding - 70 lines with identification code - Programming with rotary switch - One-person maintenance and range measurement - Rapid alarm localising - 10-year power supply via Genius Hx Article number Illustration Radio frequency: MHz Radio range: min. 100 m free field VdS approval: G Description and technical data 4 Securiton Product Catalogue 2016 Genius Home Smoke Detector

232 1. Smoke alarm device Home Smoke Detector Genius H Genius Plus (Hekatron packing) Genius Plus-N (neutral packing) Process-controlled smoke alarm device (DIN EN 14604) with optical and audible signalling for use in living areas. - Smartsonic for transferring data, as battery status, dust level and more to the Genius App. - Multicolour led (green, orange, red) for easy status identification. - Door sensor for temperature fluctuations - Service support by means of soiling prognosis - Continuous self-monitoring - Alarm threshold tracking - One-hole, two-hole mounting or adhesion mounting - Large Test button - Fault suppression and reduced light strength at night with a real-time clock - Frequency-optimised signal tone - Permanently built-in battery, typical battery life 10 years - Standalone Voltage supply: Battery capacity: Battery life: 3.6 V, lithium thionyl chloride battery permanently built-in 2.2 Ah approx. 10 years Ambient operating temperature: 0 C to 55 C Storage temperature: -10 C to +60 C Operating state display: Green, Orange, Red Audible alarm: 85 db (3 m) Protection type: IP 40 Colour: White satin finish Dimensions (H x Ø): 48 mm x 104 mm Weight: 143 g VdS approval: G Securiton Product Catalogue 2016 Genius Home Smoke Detector 5

233 Home Smoke Detector Genius H Genius H-S (Securiton packing) Genius H-N (neutral packing) Process-controlled smoke alarm device (DIN EN 14604) with optical and audible signalling for use in living areas. - Door sensor for temperature fluctuations - Service support by means of soiling prognosis - Continuous self-monitoring - Alarm threshold tracking - One-hole, two-hole mounting or adhesion mounting - Fault suppression and reduced light strength at night with a real-time clock - Frequency-optimised signal tone - Permanently built-in battery, typical battery life 10 years - Standalone Voltage supply: 3.6 V, lithium thionyl chloride battery permanently built-in 2.2 Ah approx. 10 years Battery capacity: Battery life: Ambient operating temperature: 0 C to 55 C Storage temperature: -10 C to +60 C Operating state display: Red Audible alarm: 85 db (3 m) Protection type: IP 40 Colour: White satin finish Dimensions (H x Ø): 48 mm x 104 mm Weight: 143 g VdS approval: G Securiton Product Catalogue 2016 Genius Home Smoke Detector

234 Home Smoke Detector Genius Hx Genius Plus X (Hekatron packing) Genius Plus X-N (neutral packing) Process-controlled smoke alarm device (DIN EN 14604) with optical and audible signalling for use in living areas. - Smartsonic for transferring data, as battery status, dust level and more to the Genius App. - Multicolour led (green, orange, red) for easy status identification. - Interface for holding a Basic or Pro radio module - Door sensor for temperature fluctuations - Service support by means of soiling prognosis - Continuous self-monitoring - Alarm threshold tracking - One-hole, two-hole mounting or adhesion mounting - Large Test button - Fault suppression and reduced light strength at night with a real-time clock - Frequency-optimised signal tone - Permanently built-in battery, typical battery life 10 years Voltage supply: 2 x 3.6 V, lithium thionyl chloride battery permanently built-in 2.2 Ah per battery approx. 10 years Battery capacity: Battery life: Ambient operating temperature: 0 C to 55 C Storage temperature: -10 C to +60 C Operating state display: Green, Orange, Red Audible alarm: 85 db (3 m) Protection type: IP 40 Colour: White satin finish Dimensions (H x Ø): 48 mm x 104 mm Weight: 162 g VdS approval: G Securiton Product Catalogue 2016 Genius Home Smoke Detector 7

235 Home Smoke Detector Genius Hx Genius Hx-S (Securiton packing) Genius Hx-N (neutral packing) Process-controlled smoke alarm device (DIN EN 14604) with optical and audible signalling for use in living areas. - Interface for holding a Basic or Pro radio module - Door sensor for temperature fluctuations - Service support by means of soiling prognosis - Continuous self-monitoring - Alarm threshold tracking - One-hole, two-hole mounting or adhesion mounting - Fault suppression and reduced light strength at night with a real-time clock - Frequency-optimised signal tone - Permanently built-in battery, typical battery life 10 years Voltage supply: Battery capacity: Battery life: 2 x 3.6 V, lithium thionyl chloride battery permanently built-in 2.2 Ah per battery approx. 10 years Ambient operating temperature: 0 C to 55 C Storage temperature: -10 C to +60 C Operating state display: Red Audible alarm: 85 db (3 m) Protection type: IP 40 Colour: White satin finish Dimensions (H x Ø): 48 mm x 104 mm Weight: 162 g VdS approval: G Radio Manual Call Point FH Genius Radio call point,- Interface FH, Genius The radio call point can be used as a manual call point as well as an radio interface Radio frequency: Radio range: Size (B x H x T): MHz min. 100 m free field 130 x 130 x 32mm 8 Securiton Product Catalogue 2016 Genius Home Smoke Detector

236 2. Radio module Radiomodule for Genius Plus X Radiomodule for Genius Plus X FM.Basis X Radio module for wirelessly networking multiple Genius Hx smoke alarm devices with each other for area-wide alarm signalling. - Repeater for alarm forwarding - 70 lines with identification code - Programming with rotary switch - One-person maintenance and range measurement - Rapid alarm localising - 10-year power supply via Genius Plus X - Plug & Play instalaltion Radio frequency: MHz Radio range: min. 100 m free field VdS approval: G FM.Pro X Radio module for wirelessly networking multiple Genius Hx smoke alarm devices with each other for area-wide alarm signalling. - Repeater for alarm forwarding - Radio link monitoring for signalling if there is a failure in the radio network - Dismantling detection - Six group alarm lines for alarm transmission to a central point, e.g. in the stairwell - 70 lines with identification code - Programming with rotary switch - One-person maintenance and range measurement - Rapid alarm localising - 10-year power supply via Genius Plus X - Plug & Play instalaltion Radio frequency: MHz Radio range: min. 100 m free field VdS approval: G Securiton Product Catalogue 2016 Genius Home Smoke Detector 9

237 Radiomodule for Genius Hx Basic Radiomodule for Genius Hx Pro FM. Basic-S (Securiton packing) FM. Basic Radio module for wirelessly networking multiple Genius Hx smoke alarm devices with each other for area-wide alarm signalling. - Repeater for alarm forwarding - 70 lines with identification code - Programming with rotary switch - One-person maintenance and range measurement - Rapid alarm localising - 10-year power supply via Genius Hx Radio frequency: MHz Radio range: min. 100 m free field VdS approval: G FM. Pro-S (Securiton packing) FM. Pro Radio module for wirelessly networking multiple Genius Hx smoke alarm devices with each other for area-wide alarm signalling. - Repeater for alarm forwarding - Radio link monitoring for signalling if there is a failure in the radio network - Dismantling detection - Six group alarm lines for alarm transmission to a central point, e.g. in the stairwell - 70 lines with identification code - Programming with rotary switch - One-person maintenance and range measurement - Rapid alarm localising - 10-year power supply via Genius Hx Radio frequency: MHz Radio range: min. 100 m free field VdS approval: G Securiton Product Catalogue 2016 Genius Home Smoke Detector

238 3. Accessories for smoke alarm devices Adhesive pad Genius H/Hx Adhesive pad Adhesive pad Adhesive pad for adhesive mounting of the Genius H and Genius Hx smoke alarm device on surfaces which are smooth, flat, undamaged, clean, dust-free, grease-free and solvent-free. Size (Ø x H): Colour: 88 x 1 mm Double-sided adhesive plastic foam White Seal for Genius H/Hx Seal set Mechanical protection against sabotage and theft. 32 pcs. per packaging unit Securiton Product Catalogue 2016 Genius Home Smoke Detector 11

SecuriFire 500/1000/2000/3000

SecuriFire 500/1000/2000/3000 SecuriFire 500/1000/2000/3000 Product Catalogue 2013 Content 1. Cabinets variants... 11 1.1. SecuriFire 500 fire alarm control panel... 11 1.2. SecuriFire 1000 fire alarm control panel... 12 1.3. SecuriFire

More information

SecuriFire fire detection systems. System description

SecuriFire fire detection systems. System description SecuriFire fire detection systems System description The SecuriFire system family Table of contents 1 The SecuriFire system family 3 1.1 Fire alarm control panel 3 1.2 Extinguishing control panel 4 2

More information

SecuriFire. SecuriLine Unit B6-LXI2. Technical Description. Securiton AG Alpenstrasse Zollikofen Switzerland

SecuriFire. SecuriLine Unit B6-LXI2. Technical Description. Securiton AG Alpenstrasse Zollikofen Switzerland SecuriFire SecuriLine Unit B6-LXI2 Technical Description Securiton AG Alpenstrasse 20 3052 Zollikofen Switzerland T 8 067 en Imprint Imprint This document, T 8 067, is valid only for the product described

More information

SecuriFire SecuriLine extended board B5-DXI2

SecuriFire SecuriLine extended board B5-DXI2 SecuriFire SecuriLine extended board B5-DXI Technical description Securiton AG Alpenstrasse 0 305 Zollikofen Switzerland T 8 3 en c Imprint Imprint This document, T 8 3, is valid only for the product

More information

FC722 Fire control panel

FC722 Fire control panel FC722 Fire control panel Series FS720 (MPXS) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as

More information

Fire control panels FC726 FC726-XA

Fire control panels FC726 FC726-XA Fire control panels FC726 FC726-XA Modular, pre-confectioned, microprocessor-controlled fire control panel for up to max. 1512 device addresses Integrated, user-friendly operating unit Detection and automatic

More information

FC722 Fire control panel

FC722 Fire control panel FC722 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as

More information

FC724 Fire control panel

FC724 Fire control panel FC724 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as

More information

Fire control panel detect 3004 plus and accessories

Fire control panel detect 3004 plus and accessories Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be

More information

FC724 Fire control panel

FC724 Fire control panel FC724 Fire control panel Series FS720 (IP5) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

FC2020 Fire control panel

FC2020 Fire control panel FC2020 Fire control panel Series FS20 (MP4.0) Sinteso Compact, prefabricated, microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as stand-alone

More information

SecuriFire 500. Mounting and Installation. Technical Description. Securiton AG Alpenstrasse Zollikofen Switzerland

SecuriFire 500. Mounting and Installation. Technical Description. Securiton AG Alpenstrasse Zollikofen Switzerland SecuriFire 500 Mounting and Installation Technical Description Securiton AG Alpenstrasse 20 3052 Zollikofen Switzerland T 8 065 en Imprint Imprint Notice This document, T 8 065, is valid only for the

More information

FC723 Fire control panel

FC723 Fire control panel FC723 Fire control panel FS720 series (IP5) Cerberus PRO Modular, prefabricated, microprocessor-controlled fire control panel with integrated user-friendly operating unit for up to max. 756 addresses Processes

More information

Fire control panel for modernization

Fire control panel for modernization Sinteso Fire control panel for modernization FC2030 Modular, pre-assembled fire control panel with integrated, user-friendly operating unit for gradual migration to Sinteso. Fire control panel for a maximum

More information

FC2040. Fire control panel. Sinteso. FS20 series, MP6

FC2040. Fire control panel. Sinteso. FS20 series, MP6 FC2040 Sinteso Fire control panel FS20 series, MP6 Compact, pre-assembled, microprocessor-controlled fire control panel with integrated operating unit for up to 504 addresses Fire control panel can be

More information

SecuriSens LIST Product Catalogue 2015

SecuriSens LIST Product Catalogue 2015 SecuriSens LIST Product Catalogue 2015 Content 1. Processor Units... 5 2. Cable... 7 3. Accessories List... 8 4. Spare Parts... 13 5. Services... 15 6. Product Type Index... 16 2 Securiton Product Catalogue

More information

BX-MDI8 Input module for SecuriLine extended

BX-MDI8 Input module for SecuriLine extended Input module for Securi extended Beginning with edition number 0-0007-0-03 The has 8 monitored inputs for connecting detection zones or for polling potential-free contacts. The module requires a redundant,

More information

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel Synova TM Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches unnecessary Automatic

More information

Fire control panels FC360

Fire control panels FC360 Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses

More information

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel Synova Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches, punch cards, etc. unnecessary

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in

More information

561-MB256 plus. Intruder alarm control panel. Performance features

561-MB256 plus. Intruder alarm control panel. Performance features 561-MB256 plus Intruder alarm control panel The intruder alarm control panel 561-MB256 plus is designed for use in private and commercial zones and is highly suitable for setting up medium to large-sized

More information

Sinteso TM product catalog.

Sinteso TM product catalog. Sinteso product catalog Sinteso TM product catalog. Fire protection products and accessories. Siemens Switzerland Ltd Building Technologies Group International Headquarters Gubelstrasse 22 CH-6301 Zug

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

Fire Detection Systems Product Catalogue (Version )

Fire Detection Systems Product Catalogue (Version ) Fire Detection Systems Product Catalogue (Version 2015-01) Version 2015-01 Product Catalogue Fire Detection Systems This product catalogue is intended for sales purposes only. For planning, installation,

More information

Solution F1. Fire Control Panels the new generation

Solution F1. Fire Control Panels the new generation Solution F1 Fire Control Panels the new generation Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F1 The Concept The Solution F1 Fire Control Panel range is a new

More information

Synova TM product catalog.

Synova TM product catalog. Synova product catalog Synova TM product catalog. Fire protection products and accessories. Siemens Switzerland Ltd Building Technologies Group International Headquarters Gubelstrasse 22 CH-6301 Zug Tel

More information

FC700A Fire detection control unit

FC700A Fire detection control unit FC700A Fire detection control unit Synova 4-16 Loop analogue addressable control panel 128 devices per loop (SynoLOOP) and up to 1000 devices per panel Up to 24 collective lines for Synova TM 600 serie

More information

Different types of Fire Alarm System

Different types of Fire Alarm System Different types of Fire Alarm System Conventional Fire System Generally comes with Zones. Each zone can have max 20 detectors. Addressable Fire Alarm System This comes in loops. Different manufacturer

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint

More information

FS20 Fire detection system

FS20 Fire detection system FS20 Fire detection system Components / Spare parts / Repair parts Market package 6 2015-10-23 Control Products and Systems Legal notice Technical specifications and availability subject to change without

More information

Fire and Gas Monitoring Panel ST7-HV

Fire and Gas Monitoring Panel ST7-HV Fire and Gas Monitoring Panel ST7-HV INTRODUCTION TO THE ST7-HV SYSTEM The ST7-HV system is a programmable PLC suitable for safety and security installations with a high technological and economic content

More information

For Complete Fire and Gas Solutions

For Complete Fire and Gas Solutions Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable

More information

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM Card Rack Modules CABLE DUCT MAIN SWITCH 800 mm USER INTERFACE TERMINAL PRODUCT OVERVIEW The nvent

More information

Fire alarm system EBL512 G3

Fire alarm system EBL512 G3 Fire alarm system EBL512 G3 An analog addressable fire alarm system for early detection - without any unwanted alarms. Third generation. www.panasonic-fire-security.com 2010-04-23 Page 1 of 6 The demands

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic

More information

Planning Instructions MEW01776 Revision -

Planning Instructions MEW01776 Revision - Planning Instructions MEW01776 Revision - Fire Alarm System EBL512 G3 V2.2.x Author: Jan Pettersson Date of issue: 2015-01-19 Date of rev: This page has deliberately been left blank. Table of contents

More information

SecuriSens d-list Product Catalogue 2015

SecuriSens d-list Product Catalogue 2015 SecuriSens d-list Product Catalogue 2015 Content 1. Processor Units... 5 2. Cable d-list... 7 3. Single Sensor d-list... 8 4. Accessories d-list... 9 5. ATEX components d-list... 13 6. Spare Parts d-list...

More information

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone

More information

1. MAIN CONTROL UNIT MCU Accessories for MCU OPERATING AND DISPLAY PANELS... 10

1. MAIN CONTROL UNIT MCU Accessories for MCU OPERATING AND DISPLAY PANELS... 10 Contents 1. MAIN CONTROL UNIT... 6 1.1 MCU... 6 1.2 Accessories for MCU211... 7 2. OPERATING AND DISPLAY PANELS... 10 2.1 SecuriLan... 10 2.2 SecuriLine... 15 2.3 SecuriPro cases for panels... 17 3. INPUT

More information

RAYCHEM NGC-30 COMPONENTS

RAYCHEM NGC-30 COMPONENTS PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM PRODUCT OVERVIEW CABLE DUCT Card Rack Modules TERMINAL STRIP PLINTH MAIN SWITCH 800 mm USER INTERFACE

More information

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Intelligent 2 & 4 Loop Fire Alarm Control Panels Intelligent 2 & 4 Loop Fire Alarm Control Panels Advanced has combined the latest technology with many years of fire experience, to create the Axis AX Series Intelligent Fire Alarm Control Panels. The

More information

Intelligent Single Loop Fire Alarm Control Panel

Intelligent Single Loop Fire Alarm Control Panel Intelligent Single Loop Fire Alarm Control Panel The CAX-CTL-1L Intelligent Single Loop Fire Alarm Control Panel is a member of the industry leading Axis AX Series Intelligent Fre Alarm Control Panels

More information

IQ8Control C Fire Alarm Panel

IQ8Control C Fire Alarm Panel IQ8Control C Fire Alarm Panel State-of-the-art processor technology Maximum cable length for esserbus: 3,500 m Graphics supported, high performance programming tool Innovative alarm signalling by means

More information

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones) EN 54-16 EN 54-4 1438-CPR-0527 Integrated mini PA/VA unit WW Stand alone or TCP/IP network architecture WW All in one independent wall mount EN54-4 /16 PA/VA unit WW Impedance speaker monitoring WW Remote

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

Sonos-SB Siren/Beacon

Sonos-SB Siren/Beacon Sonos-SB Siren/Beacon Audible/optical signal transmitter compliant with EN 54-3 and EN 54-23 for fire alarm systems, in red and white. Wall mounting (category W) and ceiling mounting (category C) for indoor

More information

Planning Instructions MEW01472 Revision -

Planning Instructions MEW01472 Revision - Planning Instructions MEW01472 Revision - Fire Alarm System EBL512 G3 United version 2.7.x Author: Jan Pettersson Date of issue: 2012-04-05 Date of rev: This page has deliberately been left blank. Table

More information

CODESEC FIRE ALARM SYSTEMS. security technologies

CODESEC FIRE ALARM SYSTEMS. security technologies CODESEC FIRE ALARM SYSTEMS security technologies AA402 ADRESSABLE FIRE ALARM CONTROL PANEL AA402 Electronic Addressable Intelligent Fire Alarm Control Panel Onboard one loop, 250 nodes per loop, Metal

More information

Bionics Instrument. Alarm Handling. Gas Alarm Systems

Bionics Instrument. Alarm Handling. Gas Alarm Systems Gas Alarm Systems Controllers and PLC based systems Alarm Handling Complete control at the right time and place Every gas detector consist of a gas sensor and a signal transmitter. In case of a gas leak,

More information

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 210 controller series ECL 210 The ECL Comfort 210 is an electronic weather

More information

Esmi Sense FDP Fire detection panel with ALC2 loop controller

Esmi Sense FDP Fire detection panel with ALC2 loop controller Esmi Sense FDP Fire detection panel The intelligent and modular Esmi Sense FDP fire detection panel provides multiple new features for efficient and reliable fire safety. The Esmi Sense FDP fire detection

More information

ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys

ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 310 controller series ECL 310 The ECL Comfort 310 is an electronic weather

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable

More information

Components Brochure DX CONNEXION

Components Brochure DX CONNEXION Fire Safety DX CONNEXION Morley-IAS DXc Control Panels DXc Control Panels DXc1 Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D) 714-001-111 DXc 1 Control Panel

More information

IntesisBox BACnet/IP Server - Notifier ID3000 series

IntesisBox BACnet/IP Server - Notifier ID3000 series IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet

More information

SUPREMATouch Modular Fire & Gas Detection System

SUPREMATouch Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Because every life has a purpose Class Leading Fire & Gas Detection Solutions MSA s permanent gas detection systems are relied upon by a huge number of

More information

CONTROL PANELS. Tech Data Sheet D01688GB1 10/2012 Fire Detection. Control Panels of the FX 3NET (ALC) Fire Detection System

CONTROL PANELS. Tech Data Sheet D01688GB1 10/2012 Fire Detection. Control Panels of the FX 3NET (ALC) Fire Detection System Tech Data Sheet D01688GB1 10/2012 Fire Detection CONTROL PANELS Control Panels of the FX 3NET (ALC) Fire Detection System The FX 3NET intelligent fire detection and alarm system and panels from Schneider

More information

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark Description ECL Comfort 210 controller series The ECL Comfort 210 is an electronic weather compensated

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2003-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron's MMX-2003-12NDS is a powerful intelligent networkable fire alarm solution designed

More information

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D) Components Brochure DXc Control Panels DXc Control Panels DXc1 Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D) 714-001-111 DXc 1 Control Panel DXc2 Two Loop Control

More information

Schrack Seconet Fire Alarm Systems.

Schrack Seconet Fire Alarm Systems. Sales Training. FIRE ALARM Integral IP system family. Common hardware platform Uniform firmware and PC tools For all system sizes Intelligent network structurs Hard- & software redundancy Interfaces BACnet,

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

561-MB48. Intruder Alarm Control Panel

561-MB48. Intruder Alarm Control Panel 561-MB48 Intruder Alarm Control Panel Maximum security for all eventualities The intruder alarm control panel 561-MB48 is designed for use in private and commercial buildings and is highly suitable for

More information

Basic Fire Alarm SystemTraining. Arman Alnasar

Basic Fire Alarm SystemTraining. Arman Alnasar Basic Fire Alarm SystemTraining Arman Alnasar Agenda Introduction to Esser 10 min Product Overview 5 min Control Panels 30 min Detectors 20 min Field Devices Alarm Devices 20min 10 min Management & Interface

More information

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0 IRIS Touch Quick Installation & Maintenance Guide Version 1.0 Page 2 of 16 IRIS Touch Quick Installation & Maintenance Guide Version 1.0 Contents 1. Introduction... 4 2. Product Features... 4 3. Package

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with 8, 16, 24, 32, 40 and 48 signal inputs Status retention of inputs and sequence in case

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

ME 3011C / Alarm Indication / Quick Reference Guide

ME 3011C / Alarm Indication / Quick Reference Guide Tables of Contents Page Application 1 Features 1 Important Safety Information! 2 Note to this Guide 2 Further Information 2 Device Variants 2 General Functions 3 Annunciator Sequences - ISA 18.1 3 Plan

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information

Call stations and extensions

Call stations and extensions Novigo Call stations and extensions PT2001-A1, PT2002-A1, PT2008-A1, PT2009-A1, PTO2001-A1, PTO2002-A1, PTO2003-A1, PTO2004-A1, PTO2005-A1, PTO2006-A1, PTO2008-A1 EN 54-16-certified alarm and business

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case

More information

Standard Devices. Electronic Alarm Indication Systems. ME 3011b

Standard Devices. Electronic Alarm Indication Systems. ME 3011b Standard Devices Electronic Alarm Indication Systems ME 3011b Before connecting and powering this device, please read carefully the manual, and refer to it whenever you have any doubts. This brochure is

More information

CATALOGUE Controls/Networks STRACK LIFT AUTOMATION. MULTiBUS -Coupler

CATALOGUE Controls/Networks STRACK LIFT AUTOMATION. MULTiBUS -Coupler CATALOGUE Controls/Networks 2018.1 -Coupler 1.3 Controls/Networks 2018.1 -Coupler -Coupler -Coupler Controls/Networks 2018.1 1.3 Extend (third-party) lift controls with LIFTnet, a dynamic fire control

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Phone: 040 807-0 Fax: 040 807-259 Alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC display

More information

Wireless Fire & Security Solutions. Fire Product Showcase

Wireless Fire & Security Solutions. Fire Product Showcase Wireless Fire & Security Solutions Fire Product Showcase 2 Contents Contents 3 FireCell Overview 4-5 Taktis Control Panel Overview 6 Taktis Control Panels & Accessories 7-8 Syncro AS Control Panel Overview

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

Intelligent Addressable Fire Alarm System

Intelligent Addressable Fire Alarm System Intelligent Addressable Fire Alarm System Company Profile The Company established in 2003, is manufacturing security system devices with the brand name DEKON Security Technologies for the exclusivity of

More information

SecuriRAS ASD 535 Product Catalogue 2015

SecuriRAS ASD 535 Product Catalogue 2015 SecuriRAS ASD 535 Product Catalogue 2015 Content 1. Aspirating Systems... 5 1.1. ASD Base Units... 5 1.2. Smoke Sensing Devices (SSD)... 6 1.3. Expansions & Interfaces... 7 2. Engineering and Configuration

More information

600 Range Dialer Installation Manual. Version 1.0

600 Range Dialer Installation Manual. Version 1.0 600 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2003-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2003-12NDS Network Fire Alarm Control Unit offers modular components to meet a

More information

SecuriRAS ASD 531/532/535

SecuriRAS ASD 531/532/535 SecuriRAS ASD 531/532/535 Product Catalogue 2016 Content 1. Aspirating Systems... 5 1.1. ASD Base Units... 5 1.2. Smoke Sensors (SSD)... 7 1.3. Expansion modules... 8 1.4. Demo and Test Equipment... 10

More information

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range Fire Detection MINERVA Marine MX T2000 Panel Range Features: Enhances fire detection and eliminates unwanted alarms using fuzzy logic Assists fire fighting and training by providing on-screen risk management

More information

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment

More information

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification February 11, 2019 Master Panel Product Description The Master Panel shall provide lead/lag control and time based, automatic rotation of up to eight (8) boilers, when used in conjunction with LMV3 or LMV5

More information

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System SHIFT TEST BACK ENTER C910 SERIES STATUS OUTPUT ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM ACS-30 System MONITOR CONFIG POWER CONTROL MODULE ACCS-PCM-5 PROGRAMMABLE SINGLE POINT HEAT-TRACING CONTROLLER

More information

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: / Planungsbüro + Service: Esteraustr. 10, 56379 Holzappel Tel.: 0 64 39 / 90 19 90 Fax.: 0 64 39 / 90 19 91 E-Mail: u.ramakers@umsitec.de Entwicklung + Fertigung + Service: Heerweg 15 D, 73770 Denkendorf

More information

Installation, Operating and Maintenance Manual

Installation, Operating and Maintenance Manual STATUS ZONES CONTROLS FIRE FAULT DISABLED FIRE 1 2 3 4 5 6 7 8 TEST FAULT DISABLED 1 5 BUZZER SILENCE RESET 1 2 TEST 2 6 LAMP TEST 3 SUPPLY 3 7 SYSTEM FAULT 4 8 SOUNDERS ACTIVATE/ SILENCE 4 FAULTS INSTRUCTIONS

More information

Vocia VACIE. Reference Guide

Vocia VACIE. Reference Guide Vocia VACIE Reference Guide Document Revision 1.2.3, August 2015 Biamp Systems 9300 SW Gemini Drive Beaverton, Oregon 97008, U.S.A. (503) 641-7287 www.biamp.com INTRODUCTION... 3 SECTION 1... 4 VACIE CONFIGURATION...

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols) Nitin Ventures FZE. (A Division of Nitin Fire Protection Industries Ltd.) BETTER TO BE SAFE Discovery Analogue Addressable Fire Alarm Panels Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA

More information

VACIE REFERENCE GUIDE REVISION 1.2.6

VACIE REFERENCE GUIDE REVISION 1.2.6 VACIE REFERENCE GUIDE REVISION 1.2.6 November 2016 INTRODUCTION... 3 SECTION 1... 4 VACIE CONFIGURATION... 4 Communications... 4 Vocia VACIE Devices... 4 Vocia Support devices:... 5 Power Supply and Network

More information

RACK MONITORING SYSTEM - RAMOS Ultra

RACK MONITORING SYSTEM - RAMOS Ultra CONTEG DATA SHEET version: 9-05-0 COMPLEMENTARY SYSTEMS RACK MONITORING SYSTEM marketing@dafnia.com www.dafnia.com ABU DHABI UAE +97 55575 DUBAI JAFZA +97 4 5995 +97 4 8840 MUSCAT DOHA OMAN +968 4 75005

More information

ModBus DE-1 INSTALLATION AND USER MANUAL

ModBus DE-1 INSTALLATION AND USER MANUAL ModBus DE-1 INSTALLATION AND USER MANUAL INTESIS Software, SL Distributed by DURAN ELECTRONICA S.L Tomás Bretón 50 28045 MADRID, España duran@duranelectronica.com www.duranelectronica.com 2 2010 DURAN

More information

Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel

Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel R33/422 Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel SIGMASYS M multifunctional danger alarm control and indicating panel Application Description Features

More information

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation FT080 Fire terminal (Touch) Mounting Installation 06-0-08 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Transmittal,

More information

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation FT080 Fire terminal (Touch) Mounting Installation 0-09-0 Control Products and Systems Legal notice Legal notice Technical specifications and availability subject to change without notice. Siemens Switzerland

More information

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable Protec Protec Fire Detection Pty Ltd Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network ADDRESSING SAFETY SYSTEMS WITH INTELLIGENCE CAUTION

More information