SINGLE CONVENIENCE OUTLET, WALL MOUNTED RECESSED +18" AFF

Size: px
Start display at page:

Download "SINGLE CONVENIENCE OUTLET, WALL MOUNTED RECESSED +18" AFF"

Transcription

1 LUORESCENT STRIP SURACE/PENDANT MOUNTED ' X ' LUORESCENT RECESS MOUNTED LUORESCENT STRIP RECESS MOUNTED LUORESCENT STRIP WALL MOUNTED LUORESCENT STRIP RECESS MOUNTED LUORESCENT EMERGENCY STRIP SURACE/PENDANT MOUNTED LUORESCENT STRIP SURACE/PENDANT MOUNTED LUORESCENT EMERGENCY STRIP SURACE/PENDANT MOUNTED ' X ' LUORESCENT RECESS MOUNTED ' X ' LUORESCENT SURACE/PENDANT MOUNTED ' X ' LUORESCENT EMERGENCY LIGHT ' X ' LUORESCENT WALL MOUNTED EMERGENCY LIGHT ' X ' LUORESCENT WALL MOUNTED ' X ' LUORESCENT RECESS MOUNTED ' X ' LUORESCENT SURACE/PENDANT MOUNTED D D SC P OS PL K OS BP TS SINGLE POLE TOGGLE SWITCH WAY TOGGLE SWITCH WAY TOGGLE SWITCH PILOT LIGHTED TOGGLE SWITCH KEY OPERATED TOGGLE SWITCH OCCUPANCY SENSOR WALL MOUNTED +8" A DIMMER SWITCH WAY DIMMER SWITCH CEILING AN VARIABLE SPEED CONTROLLER PHOTOCELL +8" A +8" A +8" A +8" A +8" A +8" A +8" A BYPASS SWITCH WALL MOUNTED AT 6" BELOW CEILING ( WAY TOGGLE SWITCH) TIMER SWITCH WALL MOUNTED AT 8" A OCCUPANCY SENSOR CEILING MOUNTED +8" A J J TP GI GI TP TP GI NEMA X-X SINGLE CONVENIENCE OUTLET, WALL MOUNTED RECESSED +8" A DUPLEX CONVENIENCE OUTLET, WALL MOUNTED RECESSED +8" A DUPLEX CONVENIENCE OUTLET, TAMPER PROO, WALL MOUNTED RECESSED +8" A GI DUPLEX CONVENIENCE OUTLET, WALL MOUNTED RECESSED +8" A GI DUPLEX CONVENIENCE OUTLET, TAMPER PROO, WALL MOUNTED RECESSED +8" A DUPLEX CONVENIENCE OUTLET, WALL MOUNTED RECESSED ABOVE COUNTER +" A DOUBLE DUPLEX CONVENIENCE OUTLET, WALL MOUNTED RECESSED +8" A DOUBLE DUPLEX CONVENIENCE OUTLET, TAMPER PROO, WALL MOUNTED RECESSED +8" A GI DOUBLE DUPLEX CONVENIENCE OUTLET, WALL MOUNTED RECESSED +8" A DOUBLE DUPLEX CONVENIENCE OUTLET, WALL MOUNTED RECESSED ABOVE COUNTER +" A DUPLEX CONVENIENCE OUTLET, CEILING MOUNTED RECESSED SPECIAL PURPOSE OUTLET, WALL MOUNTED RECESSED +8" A SEE NOTE ON PLAN OR SIZE LOOR MOUNTED OUTLET, SEE PLAN OR TYPE AND SIZE WALL MOUNTED JUNCTION BOX WITH INISHED BLANK COVER PLATE, WALL MOUNTED RECESSED +8" A JUNCTION BOX ABOVE CEILING T D T # AWG CONDUCTORS IN /" CONDUIT. UNO HOT/SWITCHED CONDUIT DOWN CONDUIT UP CONDUIT CAPPED CONDUIT CONCEALED IN SLAB CONDUIT EXPOSED CONDUIT CONCEALED IN WALL OR ABOVE CEILING WIREWAY / WIREMOLD WIREMOLD WITH DUPLEX RECEPTACLE DIVIDED WIREMOLD WITH DUPLEX RECEPTACLE AND DATA/TELEPHONE OUTLET AS INDICATED VERTICAL WIREWAY CABLE TRAY " CONDUIT SLEEVE MINIMUM 0% ILL UNLESS NOTED OTHERWISE GROUND,,5 - `A' NEUTRAL CIRCUIT NUMBERS TO SINGLE POLE 0 AMP CB UNLESS OTHERWISE NOTED PANEL DESIGNATION EXISTING DEMOLITION WORK NEW WORK A ABOVE INISHED LOOR AG ABOVE INISHED GRADE TO TOP O IXTURE BO BOTTOM O IXTURE UCR UNDER CABINET RECESSED AUX AUXILARY AL ALUMINUM C CONDUIT CB CIRCUIT BREAKER CKT CIRCUIT EWC ELECTRIC WATER COOLER GRD GROUND GI GROUND AULT CIRCUIT INTERRUPTER MCB MAIN CIRCUIT BREAKER MLO MAIN LUG ONLY NC NORMALLY CLOSED NO NORMALLY OPEN N NON USED WP WEATHERPROO EC ELECTRICAL CONTRACTOR UNO UNLESS NOTED OTHERWISE NTS NOT TO SCALE ARC ALUMINUM RIGID CONDUIT EMT ELECTRICAL METALLIC TUBING GRC GALVINIZED RIGID CONDUIT IMC INTERMEDIATE METAL CONDUIT PVC PVC COATED CONDUIT. ALL MOUNTING HEIGHTS ARE AS GIVEN UNLESS OTHERWISE NOTED ON PLANS. ALL MOUNTING HEIGHTS ARE TO CENTER O DEVICE, LIGHT IXTURE UNLESS OTHERWISE NOTED ' X ' LUORESCENT EMERGENCY LIGHT ' X ' LUORESCENT RECESS MOUNTED ' X ' LUORESCENT EMERGENCY LIGHT ' X ' LUORESCENT SURACE/PENDANT MOUNTED ' X ' LUORESCENT SURACE/PENDANT MOUNTED EMERGENCY ' X 8' LUORESCENT RECESS MOUNTED ' X 8' EMERGENCY LUORESCENT RECESS MOUNTED ' X 8' LUORESCENT SURACE/PENDANT MOUNTED ' X 8' LUORESCENT WALL MOUNTED ' X 8' LUORESCENT EMERGENCY WALL MOUNTED INCANDESCENT, C DOWN LIGHT, HIGH INTENSITY DISCHARGE TYPE IXTURE, ETC. RECESS MOUNTED INCANDESCENT, C DOWN LIGHT, HIGH INTENSITY DISCHARGE TYPE IXTURE, ETC. SURACE/PENDANT MOUNTED INCANDESCENT, C DOWN LIGHT, HIGH INTENSITY W/EMERGENCY LIGHT INCANDESCENT, C DOWN LIGHT, HIGH INTENSITY DISCHARGE TYPE IXTURE, ETC. WALL MOUNTED INCANDESCENT, C DOWN LIGHT, HIGH INTENSITY W/EMERGENCY LIGHT TYPE IXTURE, ETC. WALL MOUNTED EXIT SIGN (L.E.D.) CEILING MOUNTED EXIT SIGN (L.E.D.) WALL MOUNTED END EXIT SIGN (L.E.D.) WALL MOUNTED LAT BATTERY PACK LIGHTING IXTURE WALL MOUNTED CEILING AN POLE MOUNTED LIGHTING IXTURE (NUMBER O HEADS AS SHOWN) BOLLARD LIGHTING IXTURE GRADE MOUNTED ACCENT/LOOD LIGHTING IXTURE GRADE MOUNTED V## R CD DH H W TS SD DD RTS CM MM ACP AAN ASE C V## DMM PULL STATION WALL MOUNTED +8" A PULL STATION WITH ALARM COVER, SEE SPECIICATIONS WALL MOUNTED +8" A ALARM HORN WALL MOUNTED +80" A TO BOTTOM COMBINATION ALARM HORN AND VISUAL DEVICE WALL ## INTENSITY O STROBE (5/75 UNLESS OTHERWISE SPECIIED) MOUNTED +80" A TO BOTTOM VISUAL DEVICE WALL MOUNTED +80" A TO BOTTOM IRE ALARM RELAY CARBON MONOXIDE DETECTOR MAGNETIC DOOR HOLD-OPEN HEAT DETECTOR RATE O RISE WATER LOW SWITCH TAMPER SWITCH SMOKE DETECTOR SMOKE DETECTOR DUCT MOUNTED REMOTE TEST SWITCH IRE ALARM CONTROL MODULE IRE ALARM MONITOR MODULE IRE ALARM DUAL MONITOR MODULE IRE ALARM CONTROL PANEL IRE ALARM ANNUNCIATOR IRE ALARM SIGNAL EXTENDER ATS VD CP M R J M PL M VAV X-X LIGHTING PANELBOARD DISTRIBUTION PANEL MOTOR CONTROL CENTER AUTOMATIC TRANSER SWITCH VARIABLE REQUENCY DRIVE ACTORY WIRED CONTROL PANEL SINGLE PHASE MANUAL MOTOR STARTER WITH PILOT LIGHT DISCONNECT SWITCH MAGNETIC STARTER PHASE MAGNETIC STARTER PHASE COMBINATION MAGNETIC STARTER/DISCONNECT SWITCH PHASE COMBINATION MAGNETIC STARTER/DISCONNECT SWITCH PHASE 08V, PHASE MOTOR 80V, PHASE MOTOR 0V, PHASE MOTOR 08V, PHASE MOTOR TRANSORMER, SIZE AND TYPE AS NOTED CURRENT TRANSORMERS (C.T.'S) METER METER RELAY SWITCHBOARD TRANSORMER, SEE PLAN OR TYPE AND SIZE NORMALLY CLOSED CONTACT NORMALLY OPEN CONTACT VAV JUNCTION BOX WITH TOGGLE SWITCH TOGGLE SWITCH DUPLEX RECEPTACLE MOUNTING HEIGHT SURACE MOUNTED WIREMOLD BOX SPECIAL PURPOSE RECEPTACLE LIGHTING IXTURE RELAY PANEL & NUMBER (NL)-INDICATES UNSWITCHED NIGHT LIGHT DISCONNECT SWITCH MOTOR STARTER +" A abc MOUNTING HEIGHT WP +" A A() a R- WP P 60A 5A `' 5A NOTE: HASH MARKS INDICATE # AWG CONDUCTORS ONLY SEE LOOR PLANS OR OTHER EEDER CONDUCTORS AND CONDUIT SIZES SURACE MOUNTED WIREMOLD BOX SWITCH GROUP NOTE: LETTERS INDICATE NUMBER O SWITCHES AT THAT LOCATION TYPE O SWITCH TYPE WEATHER PROO BRANCH CIRCUIT NUMBER NEMA 5-0 IXTURE TYPE (SEE LIGHTING IXTURE SCHEDULE) INDICATES NUMBER O IXTURES ON THAT CIRCUIT WHEN IXTURES ARE RUN CONTINUOUSLY BRANCH CIRCUIT NUMBER SWITCH DESIGNATION (ab) - INDICATES DUAL LEVEL SWITCHING IN-BOARD AND OUT-BOARD LAMPS (NO SUBSCRIPT) - INDICATES SWITCHED BY ONE SWITCH AT DOOR INTO THAT ROOM WEATHER PROO # O POLES AMPERAGE RATING USE SIZE (N-NON USIBLE) COMBINATION MAGNETIC STARTER/DISCONNECT SWITCH STARTER SIZE USE SIZE (N-NON USIBLE) D T #D #T#D SB #D (WAP) D A (CAM) TELEPHONE OUTLET WALL MOUNTED +" A DATA OUTLET ROUGH-IN WITH EMPTY "C STUBBED ABOVE ACCESSIBLE CEILING. PROVIDE BLANK PLATE MOUNTED AT 8" A UNLESS OTHERWISE NOTED DATA OUTLET WALL MOUNTED +8" A UNLESS NOTED OTHERWISE # = MULTIPLE NUMBER O DATA CABLES BLANK OR SINGLE CABLE COMBINATION TELEPHONE AND DATA OUTLET MOUNTED +8" A UNLESS NOTED OTHERWISE # = MULTIPLE NUMBER O TELEPHONE OR DATA CABLES BLANK OR SINGLE CABLE DATA OUTLET OR SMARTBOARD. SINGLE GANG ROUGH-IN WITH "C STUBBED UP ABOVE ACCESSIBLE CEILING. PROVIDE BLANK PLATE, WALL MOUNTED +8" A UNLESS NOTED OTHERWISE. A/V OUTLET OR SMARTBOARD. -/6" SQUARE BOX, -/8" DEEP, DOUBLE GANG ROUGH-IN WITH () TWO -/"C STUBBED UP ABOVE ACCESSIBLE CEILING. PROVIDE BLANK PLATE, WALL MOUNTED +" A UNLESS NOTED OTHERWISE. LOOR MOUNTED DATA OUTLET WITH "C ROUTED IN LOOR TO NEAREST WALL AND STUBBED UP ABOVE ACCESSIBLE CEILING # = MULTIPLE NUMBER O DATA CABLES BLANK OR SINGLE CABLE DATA JACK IN JUNCTION BOX ABOVE CEILING OR UTURE WIRELESS ACCESS POINT. PROVIDE 5T SERVICE LOOP AT OUTLET. SERVICE LOOP SHALL BE COILED IN ACCESSIBLE CEILING SPACE WHEN OUTLET IS LOCATED IN AREAS OPEN TO STRUCTURE. DATA JACK IN JUNCTION BOX ABOVE CEILING OR UTURE CAMERA. PROVIDE 5T SERVICE LOOP AT OUTLET. SERVICE LOOP SHALL BE COILED IN ACCESSIBLE CEILING SPACE WHEN OUTLET IS LOCATED IN AREAS OPEN TO STRUCTURE. REPRESENTS PATH THAT CONTRACTOR SHALL OLLOW OR PROVIDING J-HOOKS AT ' O.C. OR TELE/DATA DEVICES. J-HOOKS SHALL ALSO BE ROUTED ABOVE CEILINGS AT ' O.C. IN CLASSROOMS AND OICES SHOWN. " CONDUIT SLEEVE, MINIMUM 0% ILL, THROUGH WALL ABOVE CEILING OR TELE/DATA CABLE ACCESS. SEAL IN AND AROUND SLEEVE WITH IREPROOING MATERIAL. AN LITHONIA SP8GRWA577/GEB 'x' LAMP LAY-IN TROER 77 () 0/85/ECO CEILING RECESSED NEW LIGHT IXTURE AR EXISTING LIGHT IXTURE 'x' LAMP LAY-IN TROER 77 () 0/85/ECO CEILING RECESSED EXISTING LIGHT IXTURE TO BE RELOCATED, CLEANED AND RE-LAMPED EM DUAL-LITE LZ0I-0L EMERGENCY BATTERY PACK 77 INCLUDED WITH IXTURE WALL SURACE X DUAL-LITE LXURWE-I SINGLE ACE EXIT SIGN 77 INCLUDED WITH IXTURE CEILING SURACE LIGHTING IXTURE SCHEDULE NOTES: ALL IXTURES ARE "OR EQUIVALENT" EXCEPT TYPE `EM'. ALL LUORESCENT LAMPS SHALL BE OSRAM SYLVANIA `ECO', PHILIPS `ALTO' OR G.E. `ECO' WHERE AVAILABLE. ALL LAMP CATALOG NUMBERS ARE OSRAM/SYLVANIA UNLESS NOTED OTHERWISE.

2 . WHERE NEW DEVICES ARE INSTALLED IN EXISTING WALLS, CUT IN DEVICES IN LIEU O SURACE MOUNTED CONDUIT.. VERIY CAPACITY O EXISTING LIGHTING CIRCUITS. PROVIDE ADDITIONAL CIRCUITS ROM PANELS AS REQUIRED.. MOUNT ALL EMERGENCY BATTERY PACK IXTURES (TYPE 'EM') AT 8'-0" A, UNLESS NOTED OTHERWISE.. SEE SHEET E0.0 OR LIGHT IXTURE SCHEDULE. ISO. COMMON (RED) ISO. N.O. (OR) ISO. N.C. (BRN) LIGHT LEVEL (VDC OUT) (BLU) LUMINAIRE MANUACTURERS EARTHQUAKE CLIP, () PER IXTURE AT CORNERS. ATTACH WITH SHEET METAL SCREW IXTURE WHIP ROM JUNCTION BOX (6T. LONG MAX.) LUMINAIRE SUSPENSION WIRES (# AWG MIN.) ATTACHED TO STRUCTURE (TYP. OPPOSING CORNERS) NEW LOCATION O RELOCATED LIGHT IXTURE. CONNECT TO EXISTING SWITCHED LIGHTING BRANCH CIRCUITING OR EXTEND EXISTING UNSWITCHED LIGHTING BRANCH CIRCUITING TO NEW SWITCH LOCATION AND THEN TO LIGHT IXTURE. CLEAN AND RE-LAMP RELOCATED LIGHT IXTURE. CONNECT EXISTING LIGHT IXTURE TO REMAIN TO NEW LIGHTING CONTROLS OR SPACE. CONTROL (VDC OUT) (YLW) MAN. SWITCH (GRN) +VDC (IN) (VIO) LUMINAIRE. REER TO SCHEDULE CONNECT NEW EGRESS LIGHT IXTURE TO EXISTING EMERGENCY LIGHTING CIRCUIT. CONNECT NEW LIGHT IXTURE TO EXISTING LIGHTING BRANCH CIRCUITING. GY BLU (CONTROL) BLK (COMMON) RED (VDC OUT) OR (HOLD-O) BRN (HOLD-O) COMMON (GRY) WATTSTOPPER DT-00 CEILING OCCUPANCY SENSOR ARCHITECTURAL CEILING GRID H HOT (BLK) RED LUMINAIRE. REER TO SCHEDULE N NEUTRAL (WHT) NOTE: POWER PACK MOUNTED IN ACCESSIBLE CEILING SPACE VERIY EXACT LOCATION AT JOBSITE (TYPICAL) WATTSTOPPER BZ-50 POWER PACK RED LIGHT IXTURE TO ADDITIONAL LIGHTING IXTURES ACOUSTICAL CEILING GRID TWIST MINIMUM (TYP) NEUTRAL (WHT) T-BAR

3 ALTERNATE BID #. WHERE NEW DEVICES ARE INSTALLED IN EXISTING WALLS, CUT IN DEVICES IN LIEU O SURACE MOUNTED CONDUIT.. VERIY CAPACITY O EXISTING LIGHTING CIRCUITS. PROVIDE ADDITIONAL CIRCUITS ROM PANELS AS REQUIRED.. MOUNT ALL EMERGENCY BATTERY PACK IXTURES (TYPE 'EM') AT 8'-0" A, UNLESS NOTED OTHERWISE.. SEE SHEET E0.0 OR LIGHT IXTURE SCHEDULE. NEW LOCATION O RELOCATED LIGHT IXTURE. CONNECT TO EXISTING SWITCHED LIGHTING BRANCH CIRCUITING OR EXTEND EXISTING UNSWITCHED LIGHTING BRANCH CIRCUITING TO NEW SWITCH LOCATION AND THEN TO LIGHT IXTURE. CLEAN AND RE-LAMP RELOCATED LIGHT IXTURE. CONNECT EXISTING LIGHT IXTURE TO REMAIN TO NEW LIGHTING CONTROLS OR SPACE. CONNECT NEW EGRESS LIGHT IXTURE TO EXISTING EMERGENCY LIGHTING CIRCUIT. CONNECT NEW LIGHT IXTURE TO EXISTING LIGHTING BRANCH CIRCUITING.

4 . CONNECT NEW RECEPTACLES TO EXISTING RECEPTACLE BRANCH CIRCUITING. EXTEND AS REQUIRED. VERIY CAPACITY O EXISTING CIRCUITS. PROVIDE ADDITIONAL CIRCUITS ROM PANELS AND CIRCUIT BREAKERS AS REQUIRED.. ROUTE ALL VOICE/DATA CABLING TO EXISTING DATA RACK IN DATA 5A. COORDINATE ALL TELECOMMUNICATIONS WORK WITH SCHOOL DISTRICT. RACK DESIGNATION RACK CABLE# ( DIGIT) ROOM DESIGNATION A00-0 A00-0. WHERE NEW DEVICES ARE INSTALLED IN EXISTING WALLS, CUT IN DEVICES IN LIEU O SURACE MOUNTED CONDUIT. CONNECT TO SPARE CIRCUIT BREAKERS IN PANEL INDICATED; UPDATE PANEL DIRECTORY ACCORDINGLY. TEL (RED) DATA (BLUE) 0V CONNECTION TO NEW AN POWERED VAV BOX. DATA (BLUE) BLANK A00-0 NO SCALE

5 . CONNECT NEW RECEPTACLES TO EXISTING RECEPTACLE BRANCH CIRCUITING. EXTEND AS REQUIRED. VERIY CAPACITY O EXISTING CIRCUITS. PROVIDE ADDITIONAL CIRCUITS ROM PANELS AND CIRCUIT BREAKERS AS REQUIRED.. ROUTE ALL VOICE/DATA CABLING TO EXISTING DATA RACK IN DATA 5A. COORDINATE ALL TELECOMMUNICATIONS WORK WITH SCHOOL DISTRICT.. WHERE NEW DEVICES ARE INSTALLED IN EXISTING WALLS, CUT IN DEVICES IN LIEU O SURACE MOUNTED CONDUIT. CONNECT TO EXISTING RECEPTACLE CIRCUIT AS SHOWN. INSTALL OUR () 0A/-POLE CIRCUIT BREAKERS WITHIN SPACES,, 6 AND 8 IN PLACE O EXISTING 0A/-POLE CIRCUIT BREAKERS. REPLACEMENT CIRCUIT BREAKERS TO MATCH EXISTING TYPE (WESTINGHOUSE). CONNECT TO EXISTING RECEPTACLE CIRCUIT SAVED ROM DEMOLITION. 0V CONTROL POWER CONNECTION TO NEW VAV BOX; RE-USE EXISTING VAV BOX CONTROL POWER CIRCUIT; EXTEND AS NECESSARY.

6 . EXISTING IRE ALARM SYSTEM IS MANUACTURED BY EDWARDS SYSTEM TECHNOLOGIES.. CONTRACTOR SHALL REPROGRAM EXISTING EST IRE ALARM CONTROL PANEL WITH NEW ROOM NAMES AND NUMBERS. COORDINATE WITH SCHOOL DISTRICT.. WHERE NEW DEVICES ARE INSTALLED IN EXISTING WALLS, CUT IN DEVICES IN LIEU O SURACE MOUNTED CONDUIT. INSTALL NEW IRE ALARM DEVICE; CONNECT TO EXISTING IRE ALARM CABLING AND EXTEND AS NECESSARY.

7 . EXISTING IRE ALARM SYSTEM IS MANUACTURED BY EDWARDS SYSTEM TECHNOLOGIES.. CONTRACTOR SHALL REPROGRAM EXISTING EST IRE ALARM CONTROL PANEL WITH NEW ROOM NAMES AND NUMBERS. COORDINATE WITH SCHOOL DISTRICT.. WHERE NEW DEVICES ARE INSTALLED IN EXISTING WALLS, CUT IN DEVICES IN LIEU O SURACE MOUNTED CONDUIT. INSTALL NEW IRE ALARM DEVICE; CONNECT TO EXISTING IRE ALARM CABLING AND EXTEND AS NECESSARY.

8 GENERAL DEMOLITION NOTES:. ALL SYMBOLS SHOWN DASHED ARE EXISTING ELECTRICAL DEVICES TO BE REMOVED OR AS NOTED. ALL SYMBOLS SHOWN SOLID LIGHT LINE ARE EXISTING ELECTRICAL DEVICES TO REMAIN. EXISTING ELECTRICAL DEVICES WHICH ARE TO REMAIN SHALL BE EXTENDED TO BE LUSH WITH NEW INISH ON EXISTING WALLS WHERE REQUIRED.. ALL EXISTING ELECTRICAL DEVICES IN A WALL THAT IS TO BE REMOVED; ELECTRICAL CONTRACTOR SHALL DISCONNECT POWER, CUT O CONDUCTORS AND CAP CONDUIT IN LOOR OR CEILING AS REQUIRED. DEVICES ARE TO BE REMOVED ALONG WITH WALL BY GENERAL CONTRACTOR UNLESS OTHERWISE NOTED.. ALL EXISTING ELECTRICAL DEVICES TO BE REMOVED ROM WALLS WHICH ARE TO REMAIN; ELECTRICAL CONTRACTOR SHALL DISCONNECT POWER, REMOVE CONDUCTORS, REMOVE DEVICE AND PROVIDE BLANK COVERPLATES AS REQUIRED. UNLESS OTHERWISE NOTED.. OR A PORTION O A CIRCUIT WHICH IS REMOVED OR ABANDONED, RE-ESTABLISH CIRCUIT CONTINUITY OR THE PORTION O THE CIRCUIT WHICH IS TO REMAIN. 5. ALL EXISTING CONDUITS, RACEWAYS AND WIRING ROUTED IN EXISTING WALLS AND CEILING SPACES (WHICH ARE TO BE DEMOLISHED) WHICH SERVE OTHER AREAS SHALL BE REROUTED AS REQUIRED. 6. ALL EXISTING LIGHTING IXTURES THAT ARE TO BE REINSTALLED SHALL BE REPAIRED, (AS REQUIRED) CLEANED AND RELAMPED BEORE REINSTALLATION. 7. ALL EXISTING LIGHTING IXTURES THAT ARE NOTED TO BE REINSTALLED WHICH ARE NOT REINSTALLED SHALL BE RETURNED TO THE OWNER. 8. PROVIDE AND INSTALL SUPPORTS OR EXISTING CABLES AND CONDUITS ABOVE CEILING THAT ARE CURRENTLY UNSUPPORTED IN ALL AREAS WHERE CEILING IS BEING REMOVED. 9. ALL VOICE/DATA CABLING ASSOCIATED WITH REMOVED WALL OUTLETS SHALL BE REMOVED BACK TO DATA CABINET. : DISCONNECT AND REMOVE LIGHT IXTURE; SAVE OR RE-INSTALLATION. DISCONNECT AND REMOVE IRE ALARM DEVICE. DISCONNECT AND MAKE SAE EXISTING VAV BOX OR REMOVAL BY OTHERS.

9 GENERAL DEMOLITION NOTES:. ALL SYMBOLS SHOWN DASHED ARE EXISTING ELECTRICAL DEVICES TO BE REMOVED OR AS NOTED. ALL SYMBOLS SHOWN SOLID LIGHT LINE ARE EXISTING ELECTRICAL DEVICES TO REMAIN. EXISTING ELECTRICAL DEVICES WHICH ARE TO REMAIN SHALL BE EXTENDED TO BE LUSH WITH NEW INISH ON EXISTING WALLS WHERE REQUIRED.. ALL EXISTING ELECTRICAL DEVICES IN A WALL THAT IS TO BE REMOVED; ELECTRICAL CONTRACTOR SHALL DISCONNECT POWER, CUT O CONDUCTORS AND CAP CONDUIT IN LOOR OR CEILING AS REQUIRED. DEVICES ARE TO BE REMOVED ALONG WITH WALL BY GENERAL CONTRACTOR UNLESS OTHERWISE NOTED.. ALL EXISTING ELECTRICAL DEVICES TO BE REMOVED ROM WALLS WHICH ARE TO REMAIN; ELECTRICAL CONTRACTOR SHALL DISCONNECT POWER, REMOVE CONDUCTORS, REMOVE DEVICE AND PROVIDE BLANK COVERPLATES AS REQUIRED. UNLESS OTHERWISE NOTED.. OR A PORTION O A CIRCUIT WHICH IS REMOVED OR ABANDONED, RE-ESTABLISH CIRCUIT CONTINUITY OR THE PORTION O THE CIRCUIT WHICH IS TO REMAIN. 5. ALL EXISTING CONDUITS, RACEWAYS AND WIRING ROUTED IN EXISTING WALLS AND CEILING SPACES (WHICH ARE TO BE DEMOLISHED) WHICH SERVE OTHER AREAS SHALL BE REROUTED AS REQUIRED. 6. ALL EXISTING LIGHTING IXTURES THAT ARE TO BE REINSTALLED SHALL BE REPAIRED, (AS REQUIRED) CLEANED AND RELAMPED BEORE REINSTALLATION. 7. ALL EXISTING LIGHTING IXTURES THAT ARE NOTED TO BE REINSTALLED WHICH ARE NOT REINSTALLED SHALL BE RETURNED TO THE OWNER. 8. PROVIDE AND INSTALL SUPPORTS OR EXISTING CABLES AND CONDUITS ABOVE CEILING THAT ARE CURRENTLY UNSUPPORTED IN ALL AREAS WHERE CEILING IS BEING REMOVED. 9. ALL VOICE/DATA CABLING ASSOCIATED WITH REMOVED WALL OUTLETS SHALL BE REMOVED BACK TO DATA CABINET. : DISCONNECT AND REMOVE LIGHT IXTURE; SAVE OR RE-INSTALLATION. DISCONNECT AND REMOVE IRE ALARM DEVICE. DISCONNECT AND MAKE SAE EXISTING VAV BOX OR REMOVAL BY OTHERS.

FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED. x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. FLUORESCENT STRIP LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. WALL BRACKET FLUORESCENT

More information

FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED. x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. CAPITAL LETTER DENOTES TYPE, LOWER CASE LETTER DENOTES SWITCH LEG. FLUORESCENT STRIP LIGHT FIXTURE,

More information

I.C. Thomasson Associates, Inc. CONSULTING ENGINEERS 2950 KRAFT DRIVE, SUITE 500 NASHVILLE, TN. 37204 PHONE (615) 346-3400 FAX (615) 346-3550 www.icthomasson.com ICT PROJECT # 170647 HODGSON DOUGLAS landscape

More information

DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and

DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and DEMOLITION GENERAL NOTES As-built conditions have been determined from Record Drawings (if they exist), field investigations (accessible areas and equipment), and discussions with maintenance personnel

More information

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings 1 T Consultant: NOTES, SYMBOLS & ABBREVIATIONS - MECHANICAL Number Description M001 Vestibule 117 LAN/IT Coffee 115 116 Mail Room 118 114 113 112 Scanning 119 Open Office 101 FIRST FLOOR PLAN - MECHANICAL

More information

Ho-Chunk Gaming THUNDERBIRD ENGINEERING, INC. MILWAUKEE: (414) MADISON: (608)

Ho-Chunk Gaming THUNDERBIRD ENGINEERING, INC. MILWAUKEE: (414) MADISON: (608) Ho-Chunk Gaming POWER SYMBOLS X ELECTRICAL PANEL - REFER TO DRAWINGS FOR WIDTH AND PANEL SCHEDULES PANEL NAMING: XXP-#X: DENOTES PANEL FUNCTION: L = LIGHTING P = GENERAL POWER E = EMERGENCY S = OPTIONAL

More information

Electrical Design Guidelines Table of Contents

Electrical Design Guidelines Table of Contents C: Compliant Rev. 3 Dated June 13 11 NC: Non-Compliant NA: Not Applicable Page1 16.1 General 16.2 Single Line Diagrams 16.3 Electric Motor Equipment and Controls 16.4 Lighting 16.5 Emergency Lighting 16.6

More information

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods 1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,

More information

CT CABINET AND UTILITY METERING WELL AND BOOSTER PUMP CONTROL 12"x12" WIREWAY 200A MCB 200A, 120/208V, 3Ø, 4W BOARD TVSS CIA ALARM 400A, DOUBLE-THROW SWITCH PORTABLE GENERATOR CONNECTION ENCLOSURE EXISTING

More information

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED SYMBOLS AND ABBREVIATIONS ABBREVIATIONS GENERAL NOTES LINE TYPE LEGEND CIRCUITS TELECOMMUNICATION SYSTEM ING EQUIPMENT POWER DEVICES FIRE ALARM SYSTEM NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

More information

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings. DIVISION 26 ELECTRICAL SECTION 26 27 26 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings. B. Specialty switches and outlets

More information

PRAIRIE VIEW A&M UNIVERSITY AUSTIN GREAUX ENGINEERING BUILDING CHANCELLOR'S RESEARCH INITIATIVE RENOVATION PRAIRIE VIEW, TEXAS 77445

PRAIRIE VIEW A&M UNIVERSITY AUSTIN GREAUX ENGINEERING BUILDING CHANCELLOR'S RESEARCH INITIATIVE RENOVATION PRAIRIE VIEW, TEXAS 77445 C C C PRAIRIE VIEW A&M UNIVERITY GENERAL NOTE: THE INTENT I TO HAVE NO EXPOED WIRING, CONDUIT OR CABLE ON WALL OR IN OPEN CEILING. ARCHITECT I URRING OUT WALL WHERE VERTICAL CONDUIT RUN ARE NEEDED. I THERE

More information

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings. DIVISION 26 ELECTRICAL SECTION 26 51 13 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings. B. Luminaire

More information

Division 26 ELECTRICAL TABLE OF CONTENTS

Division 26 ELECTRICAL TABLE OF CONTENTS Division 26 ELECTRICAL TABLE OF CONTENTS 26 1000 GENERAL... 33 A. CODE... 3 B. RELATED SECTIONS... 3 C. ABBREVIATIONS... 3 D. DEFINITIONS... 3 E. DRAWING REQUIREMENTS... 3 F. EQUIPMENT SERVICE ACCESS AND

More information

Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram

Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram Leviton Combination Switch And Tamper Resistant Outlet Wiring Diagram Leviton SmartLockPro 15 Amp Tamper-Resistant Combination GFCI Duplex Outlet and Switch - White-R02-X7299-00W - The Home Depot. From

More information

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. SECTION 262416 - PANELBOARDS PART 1 - GENERAL 1.1 SUMMARY A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. 1.2 PERFORMANCE REQUIREMENTS A. Seismic Performance:

More information

The following narrative outlines a conceptual electrical Scope of Work for converting the Phase 2 TRW Building to an Exhibition Hall.

The following narrative outlines a conceptual electrical Scope of Work for converting the Phase 2 TRW Building to an Exhibition Hall. The following narrative outlines a conceptual electrical Scope of Work for converting the Phase 2 TRW Building to an Exhibition Hall. Demolition: The area of work shall be a complete gut ; removing all

More information

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm

More information

FACILITIES PLANNING AND CONSTRUCTION

FACILITIES PLANNING AND CONSTRUCTION ACILITIES PLANNING AND CONSTRUCTION Sheet List Table Sheet Number Sheet Title 0.0 CPR COVER E0.1 CPR IRE ALARM SYMBOL LEGEND RISER AND NOTES E1.1 CPR IRST LOOR DEMOLITION PLAN - IRE ALARM E1.2 CPR SECOND

More information

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. SECTION 262416 - PANELBOARDS PART 1 - GENERAL 1.1 SUMMARY A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards. 1.2 PERFORMANCE REQUIREMENTS A. Seismic Performance:

More information

Related Sections: TBD. Effective Date: January 1, 2016

Related Sections: TBD. Effective Date: January 1, 2016 Description: The purpose of the section is to highlight the current applicable UMCP Design Standards for the design, selection and, installation of lighting fixtures within buildings. Related Sections:

More information

SOUTHVIEW MEDICAL CENTER

SOUTHVIEW MEDICAL CENTER PROJECT TITLE: SOUTHVIEW MEDICAL CENTER ENTRANCE VESTIBULE 1997 Miamisburg Centerville Rd. Dayton, Ohio DRAWING INDEX: STRUCTURAL ARCHITECTURAL JUNE 26, 2014 Bulletin #1 - September 12, 2014 AREA OF WORK

More information

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES

DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES 2.07 ELECTRICAL GENERAL DESIGN AND CONSTRUCTION STANDARDS GENERAL DESIGN GUIDELINES - 2.07 It is expected that the electrical design professional will conform to accepted good engineering design practices.

More information

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16 Using XPoint Wireless Devices with Emergency Lighting 1 of 16 Table of Contents Introduction...3 Application Summary...3 UL924 Standard Summary...4 ER Option - Normal Power Sensing Leads...4 ER Intended

More information

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School ELECTRICAL SYSTEMS ASSESSMENT Hanover High School ELECTRICAL DISTRIBUTION SYSTEM:?? The existing electrical service consists of an underground primary service originating at a utility pole on Cedar Street,

More information

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority. Fitness Facility Addition Page 1 1.1 CODES AND STANDARDS.1 Do complete installation in accordance with the latest edition of the CSA C22.1 as amended by the latest editions of the National Building Code

More information

CHAPTER 20 SERVICE EQUIPMENT

CHAPTER 20 SERVICE EQUIPMENT SERVICE EQUIPMENT CHAPTER 20 SERVICE EQUIPMENT Service equipment includes service cabinets and the equipment and materials necessary for installation. 20.1 Signal Service Cabinet For MnDOT traffic control

More information

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT ELECTRICAL POWER AND TRANSMISSION INSTALLERS. Test Code: 5922 Version: 01

CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT ELECTRICAL POWER AND TRANSMISSION INSTALLERS. Test Code: 5922 Version: 01 CUSTOMIZED TEACHER ASSESSMENT BLUEPRINT ELECTRICAL POWER AND TRANSMISSION INSTALLERS Test Code: 5922 Version: 01 Specific competencies and skills tested in this assessment: Basic Safety Identify career

More information

HIGH BAY APPLICATIONS

HIGH BAY APPLICATIONS STAIRWELLS The IIS Inverter can operate multiple fixtures in a building s stairwell and can be wired to bypass dimmers or occupancy sensors...keeping your egress corridors lit without sacrificing your

More information

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

MEDIUM, LOW AND CONTROL VOLTAGE CABLES Related Sections U-M Design Guideline Sections: 260800 - Electrical Acceptance Tests Products Medium Voltage Primary Cables Primary power distribution cable shall be single conductor stranded copper, with

More information

Element D Services Electrical

Element D Services Electrical PART 1 - GENERAL 1.01 OVERVIEW A. This Section includes design standards and requirements for electrical service and distribution. This is a design standard and is not intended to be used as a Specification.

More information

DIVISION 16 BASIC MATERIALS, METHODS, AND REQUIREMENTS SECTION 16A-1

DIVISION 16 BASIC MATERIALS, METHODS, AND REQUIREMENTS SECTION 16A-1 DIVISION 16 BASIC MATERIALS, METHODS, AND REQUIREMENTS SECTION 16A-1 PART 1: GENERAL 1.1 SUMMARY.1 This section covers materials, methods, and requirements common to all electrical work..2 When it becomes

More information

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES

LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES LIGHT LEVEL REQUIREMENTS LOCATION Classrooms and instrumental areas- Study Halls, Lecture Rooms, Art Rooms, Offices, Libraries, Conference Rooms, Work Rooms, Shops, Laboratories and Secondary School Cafeterias.

More information

UBC Technical Guidelines Section Edition Access Control Page 1 of 5

UBC Technical Guidelines Section Edition Access Control Page 1 of 5 Page 1 of 5 1.0 GENERAL 1.1 Related UBC Guidelines.1 Section 28 05 00 Access Services: General Standards.2 Section 08 71 00 Door Hardware 1.2 Coordination Requirements.1 UBC Access Services 1.3 Description.1

More information

Library stacks and records storage 150 LB/SF live load

Library stacks and records storage 150 LB/SF live load SPACE TYPE: LIBRARY Construction Criteria The unit costs for Library space types are based on the construction quality and design features in the following table. This information has been generally organized

More information

A. Shop Drawing submittals shall include, but not be limited to, the following:

A. Shop Drawing submittals shall include, but not be limited to, the following: SECTION 26 05 53 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical

More information

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 Division 28 ELECTRONIC SAFETY AND SECURITY TABLE OF CONTENTS 28 0000 GENERAL... 2 A. DEFINITIONS...2 28 3111 DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 A. DESIGN REQUIREMENTS...2 B. CONSTRUCTION REQUIREMENTS...2

More information

ESTIMATE SET-UP PACKAGE BID SCHEDULE ENTRY AND MAINTENANCE

ESTIMATE SET-UP PACKAGE BID SCHEDULE ENTRY AND MAINTENANCE BIDDING INFORMATION BID DATE: PROJECT NAME: ADDRESS: ESTIMATE SET-UP PACKAGE BID SCHEDULE ENTRY AND MAINTENANCE ESTIMATE NO.: CITY: STATE: ZIP: PRIME: PROJECT MANAGER: PROJECT TYPE: SUB: $ SIZE: BID TIME:

More information

Construction Management at Risk Services. New North East Branch Library Project. August 3, 2018

Construction Management at Risk Services. New North East Branch Library Project. August 3, 2018 Construction Management at Risk Services New North East Branch Library Project ADDENDUM 01 August 3, 2018 1. The attendance sheets (4 pages) from the Pre-Bid Conference are attached. 2. The proposals may

More information

SECTION ADDRESSABLE FIRE ALARM SYSTEM

SECTION ADDRESSABLE FIRE ALARM SYSTEM SECTION 16723 ADDRESSABLE FIRE ALARM SYSTEM 1 PART 1 GENERAL 1.1 DESCRIPTION A. This section outlines the requirements for the installation, programming and configuration of Addressable Fire Alarm System

More information

NYC Department of Education

NYC Department of Education NYC Department of Education Building Assessment Survey 2017-2018 Asset: P.S. 314 - BROOKLYN, 330 59 STREET, New York, 11220 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2018-04-23

More information

Page 1 of General

Page 1 of General Page 1 of 8 16.1 General 1. This section covers items common to sections of CSI s Master Format - Division 16. 2. Dalhousie University is certified by IBEW for new construction and all electrical contractors

More information

Lindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2

Lindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2 Lindsay Frederick Lighting + Electrical Ron Dodson Faculty Advisor Native American Cultural Center Arizona Technical Report 2 Native American Cultural Center Technical Report 2 p. 2 Executive Summary The

More information

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS Building Code compliance is the obligation of design professionals and/or contractors. Plan Review and Inspection Guidelines are intended to be used

More information

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section "Wiring Devices" for wall-box dimmers and manual light switches.

1. Division 26 Section Electrical General Requirements. 2. Division 26 Section Wiring Devices for wall-box dimmers and manual light switches. PART 1 - GENERAL... 1 1.1 RELATED DOCUMENTS... 1 1.2 SUMMARY... 1 1.3 REFERENCES... 2 1.4 DEFINITIONS... 2 1.5 SUBMITTALS... 2 1.6 QUALITY ASSURANCE... 3 1.7 COORDINATION... 3 1.8 DELIVERY, STORAGE, AND

More information

1. Building wires and cables rated 600 V and less. 2. Connectors, splices, and terminations rated 600 V and less.

1. Building wires and cables rated 600 V and less. 2. Connectors, splices, and terminations rated 600 V and less. Copyright 2010 AlA MasterSpec Full Length 09/10 SECTION 260519- LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES PART I-GENERAL 1.1 SUMMARY A. Section Includes: 1. Building wires and cables rated 600

More information

Smart Products. Ingenious Solutions.

Smart Products. Ingenious Solutions. THE FUTURE IS ON Smart Products. Ingenious Solutions. Wiring Devices, Energy Management Solutions and Commercial Data Infrastructure Products L-200 Corporate Information 8 World Headquarters... 8 The Future

More information

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Electrical Program. Electrical Laws & Rules. Electrical RCW WAC B. Permits Inspections Access Description Directions Comments.

Electrical Program. Electrical Laws & Rules. Electrical RCW WAC B. Permits Inspections Access Description Directions Comments. Electrical Laws & Rules Licensing Electrical Work Scope Administrator Duties Certification Supervision RCW 19.28 WAC 296-46B Permits Inspections Access Description Directions Comments Electrical Program

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 27 COMMUNICATIONS SECTION PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 27 COMMUNICATIONS SECTION PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS SECTION 275116 - PUBLIC ADDRESS AND MASS NOTIFICATION SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Preamplifiers. 2. Power amplifiers. 3. Microphones. 4. Control console. 5. Loudspeakers.

More information

ELECTRICAL DESIGN BRIEF

ELECTRICAL DESIGN BRIEF 4211 Yonge Street Suite 500 Toronto Ontario M2P 2A9 416 487 8151 f 416 487 9104 smithandandersen.com ELECTRICAL DESIGN BRIEF FOR 128 HAZLETON AVENUE RESIDENTIAL CONDOMINIUM BUILDING TORONTO, ONTARIO OUR

More information

WINDSOR FOREST HIGH SCHOOL HVAC REPLACEMENT ADDENDUM #2 SAVANNAH CHATHAM COUNTY PUBLIC SCHOOL SYSTEM FEBRUARY 18, 2016

WINDSOR FOREST HIGH SCHOOL HVAC REPLACEMENT ADDENDUM #2 SAVANNAH CHATHAM COUNTY PUBLIC SCHOOL SYSTEM FEBRUARY 18, 2016 SECTION 26 2030 - LIGHTING FIXTURES PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. Drawings and general provisions of the Contract, including General and Special Conditions and Division 1 Specification Sections,

More information

Renovate MCRC Facilities Great Lakes, IL

Renovate MCRC Facilities Great Lakes, IL 6. ENGINEERING SYSTEMS REQUIREMENTS D50 ELECTRICAL SYSTEM DESCRIPTION The electrical repair work includes the design and construction of the electrical distribution system for the B3200 Marine Corps Reserve

More information

HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California ADDENDUM NO. 3

HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California ADDENDUM NO. 3 HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California 95833 September 15, 2016 Woodland Joint Unified School District Spring Lake Area Elementary School HMC No. 3535003.000 DSA Appl.

More information

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10 Belleville, Ontario Page 1 of 10 1 GENERAL 1.1 GENERAL REQUIREMENTS.1 The General Conditions of CCDC2-2008, and the General requirements of Division 1, form part of this Section and must read in conjunction

More information

IDENTIFICATION FOR ELECTRICAL SYSTEMS July Electrical Systems

IDENTIFICATION FOR ELECTRICAL SYSTEMS July Electrical Systems SECTION 26 05 54 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Nameplates. 2. Labels. 3. Wire markers. 4. Conduit markers. 5. Permanent Marking. 6. Underground

More information

ALBUQUERQUE PUBLIC SCHOOLS Facility Design & Construction / Maintenance & Operations ELECTRICAL STANDARDS DESIGN CHECKLIST

ALBUQUERQUE PUBLIC SCHOOLS Facility Design & Construction / Maintenance & Operations ELECTRICAL STANDARDS DESIGN CHECKLIST ALBUQUERQUE PUBLIC SCHOOLS Facility Design & Construction / Maintenance & Operations ELECTRICAL STANDARDS DESIGN CHECKLIST February 01, 2006 2 Project Name: Architect: Electrical Engineer: Completed By:

More information

SECTION INTRUSION DETECTION

SECTION INTRUSION DETECTION (NOTE TO DESIGNER: These Specifications are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer.) SECTION 28 16 00 INTRUSION

More information

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS

RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS RESIDENTIAL ELECTRICAL INSPECTIONS CHECKLISTS Key Questions for Residential Inspections 1. What wiring methods will be used, and are the wiring methods suitable for the conditions? 2. Will multiwire branch

More information

SECTION LIGHTING CONTROLS

SECTION LIGHTING CONTROLS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 09 23 LIGHTING CONTROLS SPEC WRITER NOTE: 1. Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable to

More information

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature DT-300 v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature Specifications Voltage...18-28VDC/VAC, half wave rectified AC Current Consumption...25

More information

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51

TABLE OF CONTENTS CHAPTER 1 GENERAL RULES CHAPTER 2 WIRING AND PROTECTION... 51 TABLE OF CONTENTS About This Textbook...xi How to Use the National Electrical Code... 1 Article 90 Introduction to the National Electrical Code... 7 90.1 Purpose of the NEC... 7 90.2 Scope of the NEC...

More information

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS

SECTION IDENTIFICATION FOR ELECTRICAL SYSTEMS SECTION 260553 IDENTIFICATION FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Nameplates and labels B. Wire and cable markers C. Conduit markers 1.2 REFERENCES A. NFPA 70 - National Electrical

More information

DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM

DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

GARCIA GALUSKA DESOUSA Consulting Engineers

GARCIA GALUSKA DESOUSA Consulting Engineers L#57297 /Page 1/July 21, 2017 ELECTRICAL SYSTEMS NARRATIVE REPORT The following is the Electrical Systems narrative, which defines the scope of work and capacities of the Power and Lighting systems, as

More information

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics. A28.1 Standard of Practice - Fire Alarm Systems NOTE: Significant revisions or additions to the previous standards are highlighted in italics. OBJECTIVE OF STANDARD To provide compliant smart addressable

More information

DIVISION SECTION ELECTRICAL. A. Provisions of General Requirements, Division 1, are a part of this section.

DIVISION SECTION ELECTRICAL. A. Provisions of General Requirements, Division 1, are a part of this section. DIVISION 16000 SECTION 16100 ELECTRICAL PART I - GENERAL 1.01 Related Documents A. Provisions of General Requirements, Division 1, are a part of this section. 1.02 This work shall include, but not necessarily

More information

CHAPTER 8 ELECTRICAL

CHAPTER 8 ELECTRICAL CHAPTER 8 0 8.1 GENERAL... 3 8.2 REQUEST FOR PROPOSAL DEVELOPMENT... 3 8.3 DESIGN DEVELOPMENT... 3 8.3.1 CONCEPT (30%) DESIGN SUBMITTAL REQUIREMENTS... 3 8.3.1.1 Concept Design Analysis... 3 8.3.1.1.1

More information

NOTICE TO ALL FIRMS. Bid RFI Questions and Answers

NOTICE TO ALL FIRMS. Bid RFI Questions and Answers Purchasing Department 227 West 27 th Street New York, NY 10001 Purchasing Dept. Tel. 212-217-3630 Purchasing Dept. Fax 212-217-3631 Purchasing@fitnyc.edu NOTICE TO ALL FIRMS Date: March 8, 2018 To: From:

More information

Appendix B. Facilities Assessment Report

Appendix B. Facilities Assessment Report Mile Lane Army Reserve Center Redevelopment Plan September 2008 Appendix B Facilities Assessment Report RKG Associates, Inc. Mile Lane Army Reserve Base Middletown, CT MEP System Evaluation For RKG Associates

More information

NYC Department of Education

NYC Department of Education NYC Department of Education Building Assessment Survey 2017-2018 Asset: P.S. 135 - QUEENS, 207-11 89TH AVENUE, New York, 11427 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2018-03-20

More information

The following information shall become and form part of the contract documents.

The following information shall become and form part of the contract documents. October 4, 206 To: Attention: Re: All Bidders All Bidders JCBE Gymnasium HVAC Upgrades BC#: 206433 Edmonds Project No.: BHM6090 All bidders, The following information shall become and form part of the

More information

3. Provide revised typed circuit directory in panelboards that have circuits removed.

3. Provide revised typed circuit directory in panelboards that have circuits removed. DIVISION 26 - ELECTRICAL 26 0501 MINOR ELECTRICAL DEMOLITION A. Coordinate utility service outages with the UND Electrical Department. B. Verify the abandoned wiring and equipment serve only abandoned

More information

Please refer to the drawing and notes for each particular plan view. Site Plan S1-1 Site Drawing. Electrical E1-1 Main Electrical Drawing

Please refer to the drawing and notes for each particular plan view. Site Plan S1-1 Site Drawing. Electrical E1-1 Main Electrical Drawing The property that I discuss is an actual property that I helped to build. My position was as the Facility/Project Manager while the building was under construction. I worked very closely with the Senior

More information

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices. SECTION 16470 PANELBOARDS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16120 - Wire and Cable. 3. 16475 - Overcurrent Protective Devices. 1.02 SYSTEM DESCRIPTION A. Performance

More information

2011 and 2014 National Electrical Code Changes Residential Only

2011 and 2014 National Electrical Code Changes Residential Only 2011 and 2014 National Electrical Code Changes Residential Only Sponsored By: and.net Instructor: Fritz Gunther, Chief Electrical Inspector 585-436-4460 www.nyeia.com NEW YORK ELECTRICAL INSPECTION AGENCY

More information

POWER YOUR ENERGY EFFICIENCY PROGRAMS. with proven lighting controls. designed to be better.

POWER YOUR ENERGY EFFICIENCY PROGRAMS. with proven lighting controls. designed to be better. POWER YOUR ENERGY EFFICIENCY PROGRAMS with proven lighting controls designed to be better. CAPTURE ENERGY SAVINGS FOR YOUR CUSTOMERS AND GROW YOUR BUSINESS WITH PROVEN LIGHTING CONTROLS. Legrand s popular

More information

3 2 1 A B D F

3 2 1 A B D F 3 2 1 A B D F A 3 2 1 A B D F 3 2 1 A B D F Mechanical, Electrical & Energy Consultants 7600 East Orchard Road, Suite 250-S Greenwood Village, CO 80111-2518 tel: 303.796.6000 Fax: 303.796.6099

More information

DIVISION 16 ELECTRICAL

DIVISION 16 ELECTRICAL DIVISION 16 ELECTRICAL Saratoga Springs / standards / 02-2004 Page - 0 ELECTRICAL SECTION 16060 GROUNDING AND BONDING PART 1 GENERAL 1.01 SECTION INCLUDES A. Grounding electrodes and conductors, equipment

More information

SECTION (16140) - WIRING DEVICES

SECTION (16140) - WIRING DEVICES SECTION 26 27 26 (16140) - WIRING DEVICES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Receptacles, Connectors, Switches, and Finish Plates. B. Related Sections: 1. Section 00 31 13.43 (00370) -

More information

CLEVELAND HEIGHTS UNIVERSITY HEIGHTS CITY SCHOOL DISTRICT MONTICELLO & ROXBORO MIDDLE SCHOOLS INTERIOR DESIGN

CLEVELAND HEIGHTS UNIVERSITY HEIGHTS CITY SCHOOL DISTRICT MONTICELLO & ROXBORO MIDDLE SCHOOLS INTERIOR DESIGN CLEVELAND HEIGHTS UNIVERSITY HEIGHTS CITY SCHOOL DISTRICT MONTICELLO & ROXBORO MIDDLE SCHOOLS INTERIOR DESIGN 04.13.2017 1 MONTICELLO INTERIOR FINISHES PAINT MOULDING WALLS ACCENT DOORS DOOR TRIM/STAIRS

More information

S AGE E NGINEERING A SSOCIATES, LLP

S AGE E NGINEERING A SSOCIATES, LLP S AGE E NGINEERING A SSOCIATES, LLP 1211 Western Avenue Albany, NY (518) 453 6091 F (518) 453 6092 Kingston Library Mechanical and Electrical Systems Field Report Date of Visits: Mechanical - September

More information

SECTION : FIRE ALARM & DETECTION SYSTEMS

SECTION : FIRE ALARM & DETECTION SYSTEMS SECTION 28 31 10: FIRE ALARM & DETECTION SYSTEMS 1. GENERAL A. This section applies to fire detection/alarm system and carbon monoxide system components and equipment installed during new construction

More information

SECTION FIRE ALARM SYSTEMS

SECTION FIRE ALARM SYSTEMS SECTION 16721 FIRE ALARM SYSTEMS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work

More information

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER PROJECT NO. CWA 2013-04 SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER BIDS RECEIVED: CITY HALL, CITY OF BESSEMER TIME: 2:00pm DATE: October 2, 2014 City of Bessemer --------------------------------------------------------------------------------------------------------------------------------------------

More information

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5 Construction Standards Page 1 of 5.1 General Description.1 The University requires that all new fire alarm system control panel, components, and devices, as required for the project, be Secutron 2900 Series

More information

GENERAL NOTES: E-OHE PRESERVE CONTINUITY OF EXISTING CIRCUIT AFTER REMOVAL OF EXISTING LIGHT POLE. EXISTING POWER UTILITY DIP POLE E-OHE

GENERAL NOTES: E-OHE PRESERVE CONTINUITY OF EXISTING CIRCUIT AFTER REMOVAL OF EXISTING LIGHT POLE. EXISTING POWER UTILITY DIP POLE E-OHE GENERAL 1. MOST UNDERGROUND UTILITIES ARE NOT INDICATED. THE UNDERGROUND UTILITIES INDICATED ARE SCHEMATIC ONLY. THE CONTRACTOR S BE RESPONSIBLE FOR JOBSITE LOCATING AND PROTECTING ALL UNDERGROUND UTILITIES

More information

Connecting Lighting & Controls

Connecting Lighting & Controls Connecting Lighting & Controls The RELOC Advantage The RELOC Savings Pipe & wire and MC cable are antiquated and inefficient. Using such labor intensive methods results in longer projects, higher on-site

More information

DIVISION 16 - ELECTRICAL

DIVISION 16 - ELECTRICAL DIVISION 16 - ELECTRICAL I. GENERAL A. This division contains the following elements: 1. Electrical Distribution System. 2. Power System. 3. Lighting System. 4. Emergency Power System. 5. Fire Alarm Detection

More information

Installation Instructions

Installation Instructions DT-300 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On features Specifications Voltage................18-28VDC/VAC, half wave rectified AC Current Consumption...............................43mA

More information

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information

Applied Lighting Controls

Applied Lighting Controls Applied Lighting Controls Updated for 2011 Better Buildings By Design Burlington, Vermont February 9, 2011 Instructor: Steven Mesh, LC, IESNA 140 Gardenside Drive, #304 San Francisco, CA 94131 415-516-8126

More information

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE The University of Arizona has implemented a Keyless Access and Security System program to provide a cost effective, efficient, and maintainable means

More information

SECTION FIRE DETECTION AND ALARM

SECTION FIRE DETECTION AND ALARM PART 1 - GENERAL 1.1 RELATED SECTIONS: Refer to Section 15300 for requirements regarding fire protection systems. 1.2 SCOPE OF SECTION: This section contains the requirements for equipment and installation

More information

L04 X01 X03 X01 R21A R21A F09 L27 R18 R16A R18 R21A KING 107 F09 F09 L27 D03A Z-38 KING 109 R21A R18 R16A R18 R21A F09 F09 X03 L27 F09 R21A R18 R18

L04 X01 X03 X01 R21A R21A F09 L27 R18 R16A R18 R21A KING 107 F09 F09 L27 D03A Z-38 KING 109 R21A R18 R16A R18 R21A F09 F09 X03 L27 F09 R21A R18 R18 REFERENCE NOTES A. SEE 0 SERIES DRAWINGS FOR CEILING & LIGHTING IN GUESTROOMS. B. SEE 00 SERIES DRAWINGS FOR CEILING & LIGHTING INFORMATION & DETAILS IN PUBLIC SPACE. C. PROVIDE EMERGENCY LIGHTING AND

More information

REPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES

REPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES PREC SION Water Systems REPLACEMENT PARTS MANUAL FOR MODEL: PWS 45-75, AED-2 & APK-4 SERIES 0004 0002 0001 PRECISION WATER SYSTEMS WATER DISTILLER MANUFACTURED BY: PRECISION DESIGN & MANUFACTURING INC.

More information

DIVISION ELECTRICAL Revised June 11, 2014

DIVISION ELECTRICAL Revised June 11, 2014 DIVISION 16 -- ELECTRICAL Revised June 11, 2014 A. GENERAL: 1. Consultants shall explicitly follow all applicable criteria listed. Any variation from these criteria must be approved by the Office of Facility

More information

IEC and NCCER Mapping for Year 1

IEC and NCCER Mapping for Year 1 Craft: 26102-14 Safety IEC and NCCER Mapping for Year 1 Perform a visual inspection on various types of ladders 102.4 STATE GENERAL SAFETY CONSIDERATIONS IN ELECTRICAL INSTALLATIONS (LADDER SAFETY, SLECTION

More information

SECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.

SECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems. SECTION 26 0553 PART 1 GENERAL 1.1 SECTION INCLUDES A. Electrical identification requirements. B. Identification nameplates and labels. C. Wire and cable markers. D. Voltage markers. E. Underground warning

More information

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM OSU PROJECT NO. 30-04-15 PAGE 1 PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment required to provide a complete and operating system of manual and automatic detection devices,

More information