PRAIRIE VIEW A&M UNIVERSITY AUSTIN GREAUX ENGINEERING BUILDING CHANCELLOR'S RESEARCH INITIATIVE RENOVATION PRAIRIE VIEW, TEXAS 77445

Size: px
Start display at page:

Download "PRAIRIE VIEW A&M UNIVERSITY AUSTIN GREAUX ENGINEERING BUILDING CHANCELLOR'S RESEARCH INITIATIVE RENOVATION PRAIRIE VIEW, TEXAS 77445"

Transcription

1 C C C PRAIRIE VIEW A&M UNIVERITY GENERAL NOTE: THE INTENT I TO HAVE NO EXPOED WIRING, CONDUIT OR CABLE ON WALL OR IN OPEN CEILING. ARCHITECT I URRING OUT WALL WHERE VERTICAL CONDUIT RUN ARE NEEDED. I THERE I LOCATION WHERE EXPOED CONDUIT I REQUIRED, LOCATION MUT BE APPROVED BY ARCHITECT/CONTRUCTION MANAGER PRIOR TO INTALLING THAT CONDUIT. 0 AC AC TECHNOLOGY PLAN - ECOND LEVEL CALE: /" = '-0" TECNOLOGY NOTE:. REER TO HEET E-0 OR ADDITIONAL CONDUIT AND CABLE. GENERAL NOTE BY YMBOL: /" TWO COMPARTMENT RACEWAY YTEM, WIREMOLD ERIE ALD000 TAINLE TEEL. UPPER COMPARTMENT HALL CONTAIN UL HEAVY DUTY PECIICATION GRADE 0 AMPERE, V, WIRE NEMA -0R, DUPLEX RECEPTACLE ON " CENTER MOUNTED ABOVE COUNTER. RECEPTACLE LOCATED WITHIN EET O O A INK HALL BE GROUND AULT CIRCUIT INTERRUPTER TYPE. ALTERNATE CIRCUIT BETWEEN RECEPTACLE ON MULTI-OUTLET RACEWAY ERVED ROM MULTIPLE BRANCH CIRCUIT A INDICATED IN THE DRAWING, MAXIMUM O () RECEPTACLE PER CIRCUIT. LOWER COMPARTMENT HALL CONTAIN PROVIION OR TELE/DATA OUTLET ON " CENTER. EE DETAIL 0/E-0. PROVIDE CABLE OR DATA OUTLET AND TERMINATE ON JACK, EE PECIICATION. WIREMOLD TO BE INTALLED BY CONTRACTOR. PROVIDE () DUPLEX DATAET ON DEDICATED CIRCUIT AND TOTAL O () QUADRAPLEX DATA/TELEPHONE AND CABLE IN THI CHAE. REER TO 0/E-0 OR ADDITIONAL INORMATION. PROVIDE () JUNCTION BOXE OR DATA OUTLET IN WIREMOLD AND AT KNEE PACE, MAKE INAL CONNECTION WITH TELE/DATA OUTLET IN CAEWORK. PROVIDE CABLE OR EACH OUTLET. EE PECIICATION. TV OUTLET MOUNTED AT '-" A..., PROVIDE CABLE TO ID ROOM. CARD READER, REER TO DETAIL 0/E-0, AND DOOR MANUACTURER RECOMMENDATION OR ADDITIONAL INORMATION. ECURITY CAMERA, RUN " CONDUIT WITH CABLE TO ID ROOM. VERIY MOUNTING HEIGHT WITH ARCH. CLOCK, COORDINATE MOUNTING HEIGHT WITH ARCHITECT. EE PECIICATION. (), WIRELE ACCE POINT. copyright 0 c gsr l andrade architects, inc. 0// IUED OR BID AND 0

2 PRAIRIE VIEW A&M UNIVERITY TELEPHONE, DATA IN I"C. TO ID ROOM TI ACP TELEPHONE INTERACE MODULE D 0A. 0V. DEDICATED EMERGENCY CIRCUIT 0 H ER DD T H ER DD T TELEPHONE, DATA IN I"C. TO "MEDIY" YTEM IN MECHANICAL ROOM IRE ALARM YTEM RIER DIAGRAM KEYED NOTE: IRE ALARM INTERACE WIRING TO TELEPHONE LINE OR MONITORING TO OTHER PEAKER/TROBE IN THI AREA. TO OTHER INITIATING DEVICE IN THI AREA. IRE ALARM YTEM RIER DIAGRAM CALE: NONE ND. LOOR T. LOOR GENERAL IRE ALARM YTEM NOTE:. CONDUIT AND WIRE HALL BE A PER MANUACTURER' RECOMMENDATION. PROVIDE HEAT DETECTOR IN MECHANICAL ROOM PACED PER MANUACTURER' RECOMMENDATION.. PROVIDE PEAKER/TROBE IN CORRIDOR, LABORATORIE, MEETING ROOM, RETROOM, OTHER COMMON AREA.. IN CORRIDOR LE THAN 0 T WIDE, PROVIDE HORN/TROBE AT 00 T. MAXIMUM PACING AND A MAXIMUM O T ROM END O CORRIDOR.. PROVIDE MOKE DETECTOR IN ELECTRICAL AND COMMUNICATION ROOM.. MONITOR ALL IRE PROTECTION YTEM TAMPER WITCHE, LOW WITCHE OR PREURE WITCHE.. PROVIDE DUCT MOKE DETECTOR IN MAIN UPPLY AND RETURN AIR DUCT O THE AIR HANDLING UNIT GREATER THAN 000 CM WITH INTEGRAL RELAY OR EMERGENCY HUTDOWN O THE UNIT ALARM. VERIY LOCATION WITH MECHANICAL.. PROVIDE MOKE DETECTOR AT ENTRANCE TO COMMON RETURN AIR HAT COVERING TWO LOOR. 9. ALL DEVICE HALL BE ADDREABLE. ALL MOKE AND HEAT DETECTOR HALL BE INTELLIGENT TYPE. 0. ACTUATION O ANY INITIATING DEVICE HALL CAUE A GENERAL ALARM BOTH AUDIBLE AND VIUAL AND HALL ALO END AN AUDIBLE AND VIUAL ALARM AT THE CENTRAL TATION WHICH IN TURN HALL NOTIY THE IRE DEPARTMENT.. IRE ALARM YTEM PLAN ARE INTENDED A A MINIMUM UGGETED DEIGN BUILD ITERIA AND COPE DOCUMENT. CONTRACTOR HALL PROVIDE COMPLETE DOCUMENT, INCLUDING COMPLETE WIRING DIAGRAM, YTEM CALCULATION, IGNED AND EALED DOCUMENT, A ACCEPTED AND APPROVED BY A.H.J.. THE IRE ALARM RIER DIAGRAM I DIAGRAMMATIC AND CONTAIN GENERAL INORMATION ONLY. OR QUANTITY O DEVICE, WIRE IZE, ADDREE, CANDELA RATING, ETC. REER TO IRE ALARM HOP DRAWING APPROVED BY CHOOL IRE MARHAL/ A.H.J. IRE ALARM ABBREVIATION & YMBOL INGLE IDED EXIT IGN INGLE IDED EXIT IGN W/ARROW DOUBLE IDED EXIT IGN DOUBLE IDED EXIT IGN W/ARROW MOKE DETECTOR H HEAT DETECTOR ER MOKE DETECTOR-ELEVATOR RETURN DD MOKE DETECTOR-DUCT TYPE MOKE DETECTOR-INGLE TATION IRE ALARM HORN-AUDIO ONLY IRE ALARM TROBE-VIUAL ONLY IRE ALARM COMBO-AUDIO/VIUAL PEAKER TROBE - CEILING MOUNTED ACP IRE ALARM PANEL IRE ALARM PULL TATION IREMAN PHONE IRE ALARM PEAKER DH DOOR HOLDER CARD READER LOW WITCH T TAMPER WITCH copyright 0 c gsr l andrade architects, inc. 0// IUED OR BID AND 0

3 PRAIRIE VIEW A&M UNIVERITY GENERAL NOTE: THE INTENT I TO HAVE NO EXPOED WIRING, CONDUIT OR CABLE ON WALL OR IN OPEN CEILING. ARCHITECT I URRING OUT WALL WHERE VERTICAL CONDUIT RUN ARE NEEDED. I THERE I LOCATION WHERE EXPOED CONDUIT I REQUIRED, LOCATION MUT BE APPROVED BY ARCHITECT/CONTRUCTION MANAGER PRIOR TO INTALLING THAT CONDUIT. T IRE ALARM GENERAL NOTE:. THE IRE ALARM YTEM HALL BE DEIGNED AND INTALLED IN ACCORDANCE WITH THE REQUIREMENT O THE NATIONAL ELECTRICAL CODE AND IN COMPLIANCE WITH NPA AND MEET LOCALLY ENORCED CODE AND ADA REQUIREMENT.. ENLIT THE ERVICE O THE IRE MARHALL TO INPECT THE ITE AND DICTATE WHERE ANY IRE ALARM DEVICE AND MOKE DETECTOR HALL BE PLACED.. THE IRE ALARM YTEM HALL ORM A COMPLETE, OPERATIVE, COORDINATED YTEM INCLUDING, BUT NOT LIMITED TO, ALARM INITIATING DEVICE, ALARM NOTIICATION APPLIANCE, CONTROL PANEL, AUXILIARY CONTROL DEVICE, ANNUNCIATOR, POWER UPPLIE AND WIRING A PECIIED.. THE CONTRACTOR HALL OBTAIN AND ENGAGE THE ERVICE O A LICENED IRE ALARM INTALLATION COMPANY TO DEIGN, INTALL AND TET THE IRE ALARM YTEM.. THE IRE ALARM YTEM HALL BE INTALLED IN ACCORDANCE WITH APPLICABLE CODE AND LOCAL AUTHORITY HAVING JURIDICTION WHETHER PECIICALLY INDICATED ON DRAWING OR ADDREED IN PECIICATION.. REER TO PECIICATION/IRE ALARM RIER DIAGRAM ON HEET A-00 OR ADDITIONAL IRE ALARM INORMATION.. ELECTRICAL CONTRACTOR HALL PROVIDE POWER OR IRE ALARM BOOTER I REQUIRED OR THE INTALLATION O ALARM DEVICE. REER TO HEET 0/E0 OR ADDITIONAL IRE ALARM DEVICE IN THI AREA * PROVIDE DOCUMENT TORAGE BOX OR A-BUILT DRAWING. EE ARCHITECTURAL.. DEVICE QUANTITIE MAY VARY AT TIME O INAL ALARM YTEM DEIGN. DEIGN DOCUMENT HALL BE ORWARDED TO CHOOL IRE MARHAL AND A.H.J. OR APPROVAL, PRIOR TO UBMITTING OR ENGINEERING APPROVAL. 9. IRE ALARM DEVICE HOWN ON DRAWING ARE A MINIMUM REQUIREMENT. IRE MARHALL HAVING JURIDICTION HALL DICTATE INAL QUANTITIE AND LOCATION O ALL A DEVICE. MAKE A PROVIION OR ADDITIONAL DEVICE. 0. REER TO IRE ALARM RIER DIAGRAM ON HEET A-00, AND PECIICATION OR MORE INORMATION. ACP ACP PROVIDE KNOX BOX IRE ALARM KEYED NOTE: TYPICAL MAGNETIC DOOR HOLDER HAVE A MINIMUM HOLDING ORCE O LB UNDER NORMAL CONDITION, THE ELECTROMAGNET I ENERGIZE TO HOLD OPEN THE DOOR IN THE EVENT O IRE. THE IRE CONTROL PANEL OR APPROVED PERIPHERAL APPLIANCE WILL AUTOMATICALLY INTERRUPT THE VOLTAGE TO THE DOOR HOLDER RELEAING THE DOOR TO PREVENT THE PREAD O MOKE. THE DOOR MAYBE MANUALLY OPENED WHEN THE DOOR I ENERGIZED. copyright 0 c gsr l andrade architects, inc. WP EGRE LIGHTING NOTE: VERIY LOCATION WITH IRE PROTECTION DEIGNER. ALL LIGHT IN LAB, CORRIDOR, TAIR, LOBBIE, ELEVATOR ARE CONNECTED TO GENERATOR BACK-UP POWER. VERIY LOCATION. ALL EGRE IGNAGE HA CODE REQUIRED BATTERY BACK-UP. ALTERNATE # UPIZE GENERATOR TO CARRY ULL LOAD O BUILDING AND WILL OPERATE ALL LIGHTING AND YTEM. 0// IUED OR BID AND 0 0 IRE ALARM YTEM PLAN - IRT LEVEL CALE: /" = '-0"

4 0 IRE ALARM YTEM PLAN - ECOND LEVEL CALE: /" = '-0" IRE ALARM GENERAL NOTE:. THE IRE ALARM YTEM HALL BE DEIGNED AND INTALLED IN ACCORDANCE WITH THE REQUIREMENT O THE NATIONAL ELECTRICAL CODE AND IN COMPLIANCE WITH NPA AND MEET LOCALLY ENORCED CODE AND ADA REQUIREMENT.. ENLIT THE ERVICE O THE IRE MARHALL TO INPECT THE ITE AND DICTATE WHERE ANY IRE ALARM DEVICE AND MOKE DETECTOR HALL BE PLACED.. THE IRE ALARM YTEM HALL ORM A COMPLETE, OPERATIVE, COORDINATED YTEM INCLUDING, BUT NOT LIMITED TO, ALARM INITIATING DEVICE, ALARM NOTIICATION APPLIANCE, CONTROL PANEL, AUXILIARY CONTROL DEVICE, ANNUNCIATOR, POWER UPPLIE AND WIRING A PECIIED.. THE CONTRACTOR HALL OBTAIN AND ENGAGE THE ERVICE O A LICENED IRE ALARM INTALLATION COMPANY TO DEIGN, INTALL AND TET THE IRE ALARM YTEM.. THE IRE ALARM YTEM HALL BE INTALLED IN ACCORDANCE WITH APPLICABLE CODE AND LOCAL AUTHORITY HAVING JURIDICTION WHETHER PECIICALLY INDICATED ON DRAWING OR ADDREED IN PECIICATION.. REER TO PECIICATION/IRE ALARM RIER DIAGRAM ON HEET A-00 OR ADDITIONAL IRE ALARM INORMATION.. ELECTRICAL CONTRACTOR HALL PROVIDE POWER OR IRE ALARM BOOTER I REQUIRED OR THE INTALLATION O ALARM DEVICE.. DEVICE QUANTITIE MAY VARY AT TIME O INAL ALARM YTEM DEIGN. DEIGN DOCUMENT HALL BE ORWARDED TO CHOOL IRE MARHAL AND A.H.J. OR APPROVAL, PRIOR TO UBMITTING OR ENGINEERING APPROVAL. 9. IRE ALARM DEVICE HOWN ON DRAWING ARE A MINIMUM REQUIREMENT. IRE MARHALL HAVING JURIDICTION HALL DICTATE INAL QUANTITIE AND LOCATION O ALL A DEVICE. MAKE A PROVIION OR ADDITIONAL DEVICE. 0. REER TO IRE ALARM RIER DIAGRAM ON HEET A-00, AND PECIICATION OR MORE INORMATION. IRE ALARM KEYED NOTE: TYPICAL MAGNETIC DOOR HOLDER HAVE A MINIMUM HOLDING ORCE O LB UNDER NORMAL CONDITION, THE ELECTROMAGNET I ENERGIZE TO HOLD OPEN THE DOOR IN THE EVENT O IRE. THE IRE CONTROL PANEL OR APPROVED PERIPHERAL APPLIANCE WILL AUTOMATICALLY INTERRUPT THE VOLTAGE TO THE DOOR HOLDER RELEAING THE DOOR TO PREVENT THE PREAD O MOKE. THE DOOR MAYBE MANUALLY OPENED WHEN THE DOOR I ENERGIZED. EGRE LIGHTING NOTE:. ALL LIGHT IN LAB, CORRIDOR, TAIR, LOBBIE, ELEVATOR ARE CONNECTED TO GENERATOR BACK-UP POWER.. ALL EGRE IGNAGE HA CODE REQUIRED BATTERY BACK-UP. ALTERNATE # UPIZE GENERATOR TO CARRY ULL LOAD O BUILDING AND WILL OPERATE ALL LIGHTING AND YTEM. 0// IUED OR BID AND 0 PRAIRIE VIEW A&M UNIVERITY GENERAL NOTE: THE INTENT I TO HAVE NO EXPOED WIRING, CONDUIT OR CABLE ON WALL OR IN OPEN CEILING. ARCHITECT I URRING OUT WALL WHERE VERTICAL CONDUIT RUN ARE NEEDED. I THERE I LOCATION WHERE EXPOED CONDUIT I REQUIRED, LOCATION MUT BE APPROVED BY ARCHITECT/CONTRUCTION MANAGER PRIOR TO INTALLING THAT CONDUIT. copyright 0 c gsr l andrade architects, inc.

5 PRAIRIE VIEW A&M UNIVERITY VB- VB- VB- VB- VB- VB- NEW " IRE ERVICE. REER TO HEET P-0 NEW " IRE RIER WITH 00 GPM VERTICAL IRE PUMP AND JOCKEY PUMP IRE PROTECTION NOTE:. CONTRACTOR I REPONIBLE OR A COMPLETE AND UNCTIONAL IRE PROTECTION YTEM INTALLATION TO THE HATCHED AREA.. THE IRE PROTECTION INORMATION PROVIDED ON THEE DRAWING AND IN THE PECIICATION I OR AITANCE IN THE BIDDING PROCE ONLY. THE IRE PROTECTION YTEM HALL BE DEIGNED BY A LICENED IRE PROTECTION ENGINEER OR NICET CERTIIED DEIGNER. THE IRE PROTECTION YTEM HALL BE DEIGNED AND INTALLED IN ACCORDANCE WITH ALL REQUIREMENT O APPLICABLE CODE AND THE AUTHORITY HAVING JURIDICTION. THE CONTRACTOR AUME ALL REPONIBILITY OR DEIGN AND INTALLATION O THE IRE PROTECTION YTEM.. ALL AREA TO BE PRINKLED WITHIN THE BUILDING HALL BE RATED OR ORDINARY GROUP HAZARD TWO UNLE OTHERWIE NOTED.. ALL JANITOR CLOET, CUTODIAN CLOET, MECHANICAL ROOM, AND ELECTRICAL ROOM HALL BE PRINKLED OR ORDINARY GROUP HAZARD ONE.. IRE PRINKLER PIPING HALL BE INTALLED ABOVE LAY-IN CEILING WHERE LAY-IN CEILING EXIT OR ARE BEING INTALLED. ROOM WITHOUT LAY-IN CEILING HALL HAVE THE PRINKLER HEAD ROUTE ALONG THE CORRIDOR WALL WITH IDEWALL HEAD. I PRINKLER PIPING HA TO BE EXPOED, PIPING HALL RUN TIGHT TO WALL A HIGH A POIBLE ALONG THE WALL WITH IDEWALL HEAD. ALL PIPING AND CONNECTOR ARE TO BE PAINTED AND PENETRATION THRU WALL ARE TO HAVE ECUTCHEON PLATE. PRINKLER PIPE LOWER THAN '-0" A HALL HAVE '-0" O.C. MAX. OTHERWIE '-0" MAX.. IT WILL BE THE REPONIBILITY O THE IRE PRINKLER CONTRACTOR TO PERORM A WATER LOW TET O THE EXITING WATER UPPLY. copyright 0 c gsr l andrade architects, inc. 0// IUED OR BID AND 0 0 IRE PROTECTION PLAN - IRT LEVEL CALE: /" = '-0"

6 PRAIRIE VIEW A&M UNIVERITY 0 IRE PROTECTION PLAN - ECOND LEVEL CALE: /" = '-0" IRE PROTECTION NOTE:. CONTRACTOR I REPONIBLE OR A COMPLETE AND UNCTIONAL IRE PROTECTION YTEM INTALLATION TO THE HATCHED AREA.. THE IRE PROTECTION INORMATION PROVIDED ON THEE DRAWING AND IN THE PECIICATION I OR AITANCE IN THE BIDDING PROCE ONLY. THE IRE PROTECTION YTEM HALL BE DEIGNED BY A LICENED IRE PROTECTION ENGINEER OR NICET CERTIIED DEIGNER. THE IRE PROTECTION YTEM HALL BE DEIGNED AND INTALLED IN ACCORDANCE WITH ALL REQUIREMENT O APPLICABLE CODE AND THE AUTHORITY HAVING JURIDICTION. THE CONTRACTOR AUME ALL REPONIBILITY OR DEIGN AND INTALLATION O THE IRE PROTECTION YTEM.. ALL AREA TO BE PRINKLED WITHIN THE BUILDING HALL BE RATED OR ORDINARY GROUP HAZARD TWO UNLE OTHERWIE NOTED.. ALL JANITOR CLOET, CUTODIAN CLOET, MECHANICAL ROOM, AND ELECTRICAL ROOM HALL BE PRINKLED OR ORDINARY GROUP HAZARD ONE.. IRE PRINKLER PIPING HALL BE INTALLED ABOVE LAY-IN CEILING WHERE LAY-IN CEILING EXIT OR ARE BEING INTALLED. ROOM WITHOUT LAY-IN CEILING HALL HAVE THE PRINKLER HEAD ROUTE ALONG THE CORRIDOR WALL WITH IDEWALL HEAD. I PRINKLER PIPING HA TO BE EXPOED, PIPING HALL RUN TIGHT TO WALL A HIGH A POIBLE ALONG THE WALL WITH IDEWALL HEAD. ALL PIPING AND CONNECTOR ARE TO BE PAINTED AND PENETRATION THRU WALL ARE TO HAVE ECUTCHEON PLATE. PRINKLER PIPE LOWER THAN '-0" A HALL HAVE '-0" O.C. MAX. OTHERWIE '-0" MAX.. IT WILL BE THE REPONIBILITY O THE IRE PRINKLER CONTRACTOR TO PERORM A WATER LOW TET O THE EXITING WATER UPPLY. copyright 0 c gsr l andrade architects, inc. 0// IUED OR BID AND 0

1/2" [15mm] HANGER ROD SECURED TO STRUCTURE ABOVE (TYP) BOSS FOR HANGER ROD WELDED. [1200mm] CC SPACING (TYP)

1/2 [15mm] HANGER ROD SECURED TO STRUCTURE ABOVE (TYP) BOSS FOR HANGER ROD WELDED. [1200mm] CC SPACING (TYP) 1/2" [15mm] HANGER ROD ECURED TO TRUCTURE ABOVE (TYP) TURNBUCKLE (TYP) PREFAB. CEILING PANEL A PECIFIED BO FOR HANGER ROD WELDED TO CHANNEL. MAX. 4'-0" [1200mm] CC PACING (TYP) 3" [75mm] 5 U CHANNEL LOCATED

More information

1. SYSTEM DESIGN PER NFPA 72 AND LIFE SAFETY SYSTEM SHALL HAVE 24 HR BACKUP BATTERIES

1. SYSTEM DESIGN PER NFPA 72 AND LIFE SAFETY SYSTEM SHALL HAVE 24 HR BACKUP BATTERIES CEILING INPUT ' MAXIMUM CEILING MOUNT 8" A... TO BOTTOM O WALL MOUNT LEN 8" A... TO MIDDLE O IRE PULL,, ACE O WALL PULL TATION IRE MANUAL TATION. YTEM DEIGN PER NPA 7 AND LIE AETY. YTEM ALL E R BACUP BATTERIE

More information

RTU 02 S x14. 16x16. 18x20 RTU x20. 10x14 S-1. MAU 01 12x12

RTU 02 S x14. 16x16. 18x20 RTU x20. 10x14 S-1. MAU 01 12x12 YMBOL & ABBREV. T D Ø DL UC M E ME A/UP RA/RET EA/EH CD/R RR/RG ER/EG FC MVD FD (L) FLE T-TAT T-TAT D DIA. DL UC UPPLY AIR (RIE/DROP) RETURN AIR DUCT (RIE/DROP) EHAUT AIR DUCT (RIE/DROP) CEILING DIFFUER/UPPLY

More information

ADDENDUM No. 1. OPSB Central Office Relocation & Renovation

ADDENDUM No. 1. OPSB Central Office Relocation & Renovation Addendum No. ADDENDUM No. Date August 7, 208 Project: OPB Central Office Relocation & Renovation NOTICE TO CONTRACTOR GENERAL: The following does hereby become a part of the Contract Documents and all

More information

SINGLE CONVENIENCE OUTLET, WALL MOUNTED RECESSED +18" AFF

SINGLE CONVENIENCE OUTLET, WALL MOUNTED RECESSED +18 AFF LUORESCENT STRIP SURACE/PENDANT MOUNTED ' X ' LUORESCENT RECESS MOUNTED LUORESCENT STRIP RECESS MOUNTED LUORESCENT STRIP WALL MOUNTED LUORESCENT STRIP RECESS MOUNTED LUORESCENT EMERGENCY STRIP SURACE/PENDANT

More information

UNDERGROUND FEEDER 120/240V - 1C + G EXISTING STORAGE BARN CONCRETE SLAB AT DOORWAY SLOPE AWAY FROM NEW FOUNDATION REMOVE

UNDERGROUND FEEDER 120/240V - 1C + G EXISTING STORAGE BARN CONCRETE SLAB AT DOORWAY SLOPE AWAY FROM NEW FOUNDATION REMOVE ¾ ¾ ¾ E00 EXITING OFFICE BUNGALOW 6.30 REMOVE FROM NEW FOUNDATION 00mmØ UBDRAIN CONCRETE LAB AT DOORWAY 2.00 00mmØ UBDRAIN GRANULAR APRON 8m - 50mmØ CP EXITING GRAVEL ENTRANCE EXITING TORAGE BARN 25kVA

More information

5383 Cambie Street AL-2 FF Path of Travel Width April 26, 2017 Project Address Title/Descriptor Initial Submission Date

5383 Cambie Street AL-2 FF Path of Travel Width April 26, 2017 Project Address Title/Descriptor Initial Submission Date AL-1 PLANNING AND DEVELOPMENT ERVICE Office of the Chief Building Official BP-2017-01610 X Alternative olution / Minor Relaxation* August 14, 2017 Related Building Permit elect One Last Revision Date APPLICANT

More information

KEY PLAN NOTE: SHADED AREAS INCLUDED IN SET RAMP LEVEL NORTH SOUTH PUMP ROOM PUMP ROOM KEY PLAN NOTE: SHADED AREAS INCLUDED IN SET ARRIVALS LEVEL

KEY PLAN NOTE: SHADED AREAS INCLUDED IN SET RAMP LEVEL NORTH SOUTH PUMP ROOM PUMP ROOM KEY PLAN NOTE: SHADED AREAS INCLUDED IN SET ARRIVALS LEVEL A2 B2 D A TERMINAL B TERMINAL A D2 C2 E2 DALLA FORT WORTH INTERNATIONAL AIRPORT E KEY PLAN NOTE: HADED AREA INCLUDED IN ET RAMP LEVEL CONTRACT NO. : 956 PERMIT NO. : A7-37B IUED FOR BID: OCTOBER, 27 PUMP

More information

THE QPL UFH EXTENSION KIT

THE QPL UFH EXTENSION KIT THE QPL UFH EXTENSION KIT The Qual-PEX underfloor heating ytem i perfectly uited to a ingle area extenion up to 40qm in floor area. It i deigned to link into an exiting radiator heating ytem or alternatively

More information

(N) LONDON PLANE STREE TREE WITH ROOT BARRIER (TYP.).INSTALL PER SMMC ,126 sf landscape (N)JAPANESE MAPLE COURTYARD TREE (TYP.

(N) LONDON PLANE STREE TREE WITH ROOT BARRIER (TYP.).INSTALL PER SMMC ,126 sf landscape (N)JAPANESE MAPLE COURTYARD TREE (TYP. 8 sf 8 sf (N) LONDON PLANE TREE TREE WITH ROOT BARRIER (TYP.).INTALL PER MMC 7.71.150. REVIED 4.1.15 1 1.7.15 CITY PLAN.H. CHECK UBMITTAL.0.15 CITY PLAN.H. CHECK COMMENT 4.1.15 CITY PLAN.H. CHECK COMMENT

More information

Installation Guide. XR5FC and XR5SL

Installation Guide. XR5FC and XR5SL Installation Guide XR5FC and XR5L Commercial Fire Panels MODEL XR5FC/XR5L COMMAND PROCEOR INTALLATION GUIDE FCC NOTICE This equipment generates and uses radio frequency energy and, if not installed and

More information

F890. Relcom Installation Instructions. 8 Segment Redundant Fieldbus Power Supply for use with non-proprietary cabled systems

F890. Relcom   Installation Instructions. 8 Segment Redundant Fieldbus Power Supply for use with non-proprietary cabled systems F890 8 egment Redundant Fieldbu Power upply for ue with nonproprietary cabled ytem F890P Intallation Intruction Relcom www.mtlfieldbu.com CONTENT PAGE 1 OVERVIEW 1 2 DECRIPTION 1 3 COMPONENT AND ACCEORIE

More information

PFC-7500/PFC-7501 Installation Manual

PFC-7500/PFC-7501 Installation Manual PFC-7500/PFC-7501 Installation Manual Fire Alarm Communicator (All specifications subject to revision.) 5757 Phantom Dr. te 125 P.O. Box 42037 t. Louis, MO 63042 (866) 240-1870 (314) 595-6900 FAX (800)

More information

F892. Relcom Installation Instructions. 8 Segment Redundant Fieldbus Power Supply for use with non-proprietary cabled systems

F892. Relcom  Installation Instructions. 8 Segment Redundant Fieldbus Power Supply for use with non-proprietary cabled systems F892 8 egment Redundant Fieldbu Power upply for ue with nonproprietary cabled ytem F892P Intallation Intruction Relcom www.mtlfieldbu.com CONTENT PAGE 1 OVERVIEW 1 2 DECRIPTION 1 3 COMPONENT AND ACCEORIE

More information

Stainless Steel Range

Stainless Steel Range PRODUCT MANUAL TR200009.r2 Stainle Steel Range SSB, SSI, and SST Intallation, Operation, and Maintenance Manual PRACTICAL, EFFICIENT & SUSTAINABLE BUILDING SERVICES SOLUTIONS Warning Thi manual hould be

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual PRODUCT MANUAL TR200009.r1 Stainle Steel Range SSB, SSI and SST Serie Intallation, Operation and Maintenance Manual P R A C T I C A L, E F F I C I E N T & S U S TA I N A B L E BUILDING SERVICES SOLUTIONS

More information

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm

More information

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

InstallatIon GuIde XR2500F addressable FIRe alarm ContRol Panel

InstallatIon GuIde XR2500F addressable FIRe alarm ContRol Panel Installation Guide XR2500F ADDREABLE FIRE ALARM CONTROL Panel MODEL XR2500F COMMAND PROCEOR INTALLATION GUIDE FCC NOTICE This equipment generates and uses radio frequency energy and, if not installed and

More information

DUCT INSTALLATION 2. INSTALL DUCTS ACCORDING TO SMACNA'S "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE" UNLESS OTHERWISE INDICATED.

DUCT INSTALLATION 2. INSTALL DUCTS ACCORDING TO SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE UNLESS OTHERWISE INDICATED. CU, HP- CU, HP- EF- DUCTWORK - AIR TERMINAL " IDEW GRILLE TAP WITH MANUAL VOLUME DAMPER, RND DUCTWORK - EQUIPMENT M BDD D EDH- FIRE DAMPER NOTE: RUNOUT IZE TO ROUND NECK DIFFUER I THE AME IZE A THE DIFFUER

More information

FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED. x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. FLUORESCENT STRIP LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. WALL BRACKET FLUORESCENT

More information

FIRE ALARM: BY OTHERS, IF REQUIRED.

FIRE ALARM: BY OTHERS, IF REQUIRED. x x x x x x OS LIGHTING S FLUORESCENT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE FOR SIZE AND MOUNTING. CAPITAL LETTER DENOTES TYPE, LOWER CASE LETTER DENOTES SWITCH LEG. FLUORESCENT STRIP LIGHT FIXTURE,

More information

NODIA AND COMPANY. Model Test Paper - I GATE Refrigeration and Air Conditioning. Copyright By Publishers

NODIA AND COMPANY. Model Test Paper - I GATE Refrigeration and Air Conditioning. Copyright By Publishers No part of thi publication may be reproduced or ditributed in any form or any mean, electronic, mechanical, photocopying, or otherwie without the prior permiion of the author. Model Tet Paper - I GATE

More information

FIRE ALARM SYSTEM SPECIFICATION A. GENERAL

FIRE ALARM SYSTEM SPECIFICATION A. GENERAL IE ALAM TEM PECIICATION A. GENEAL MBOL 1. TE IE ALAM TEM ALL BE A COMPLETE TEM O ONE O TE OLLOWING MANUACTUE: MICOM NOTIIE IEMEN EDWAD TE COMPLETE TEM ALL BE LITED B AND ALL CONIM TO ALL APPLICABLE EQUIEMENT

More information

b. For Clarification: Added Dimming Zone number next to each fixture in Computer Classroom 102.

b. For Clarification: Added Dimming Zone number next to each fixture in Computer Classroom 102. UNC New East Building D Compliant Elevator DDENDUM NO. CO ID# 6-6-0 Code: 6 Item: Chapel Hill, North Carolina December, 08 Page HUFFMN RCHITECT, P 6 PERHING ROD RLEIGH, NORTH CROLIN 7608 PHONE (99) 70-669

More information

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM DIVISION 26 ELECTRICAL SECTION 26 81 11 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install all equipment and accessories for a complete local, analog addressable, manually and automatically actuated,

More information

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 Division 28 ELECTRONIC SAFETY AND SECURITY TABLE OF CONTENTS 28 0000 GENERAL... 2 A. DEFINITIONS...2 28 3111 DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2 A. DESIGN REQUIREMENTS...2 B. CONSTRUCTION REQUIREMENTS...2

More information

EST2. Life Safety Systems Control Panels. Analog Control Panel. Standard Features. Overview

EST2. Life Safety Systems Control Panels. Analog Control Panel. Standard Features. Overview Life afety ystems Control Panels Overview The ET2 ire Alarm ystem is modular in design allowing systems to be easily configured to match installation requirements. With one ignature Data Circuit (DC) ET2

More information

INSTALLATION GUIDE XR2400F ADDRESSABLE FIRE ALARM CONTROL PANEL

INSTALLATION GUIDE XR2400F ADDRESSABLE FIRE ALARM CONTROL PANEL INTALLATION GUIDE XR2400F ADDREABLE FIRE ALARM CONTROL PANEL MODEL XR2400F Addressable Fire Alarm Control Panel INTALLATION GUIDE FCC NOTICE This equipment generates and uses radio frequency energy and,

More information

HD video and audio camera (720p) Unlimited viewing / recording of live HD video and audio streaming - anytime, anywhere

HD video and audio camera (720p) Unlimited viewing / recording of live HD video and audio streaming - anytime, anywhere Paradox Inight i the firt and only integrated olution of HD video/audio monitoring with uperior ecurity capabilitie that allow uer to ee and hear what i going on and protect their home or buine anytime,

More information

Electrical Inspection Special Electrical

Electrical Inspection Special Electrical 0941 Fire Alarm System Devices, panels, wiring, conduit, etc. Description of the building system The school is equipped with a hard wired fire alarm control panel, and automatic dialer. The fire alarm

More information

TELEPHONE: (215) Addendum No. 01. Edwin Forrest Elementary School Fire Alarm System Replacement SDP Contract No. B-008 (C) of 2017/18

TELEPHONE: (215) Addendum No. 01. Edwin Forrest Elementary School Fire Alarm System Replacement SDP Contract No. B-008 (C) of 2017/18 TE OOL DITRIT O PILADLPIA OOL REORM OMMIION Office of pitl Poms 0 Noth Bod teet, d loo uite Phildelphi, PA 0 TELEPONE: () 00-0 Addedum No. 0 ubject: Edwi oest Elemety chool ie Alm ystem Replcemet DP otct

More information

Vista Underground Distribution Switchgear Outdoor Distribution. Pull Box Specifications for UnderCover Style

Vista Underground Distribution Switchgear Outdoor Distribution. Pull Box Specifications for UnderCover Style Vita Underground Ditribution Outdoor Ditribution Pull Box Specification I. GENERAL 1.1 The pull box for the witchgear hall be deigned, detailed, and fabricated in accordance with the requirement of thi

More information

INSTALLATION GUIDE XR150/XR550 SERIES CANADIAN CONTROL PANEL

INSTALLATION GUIDE XR150/XR550 SERIES CANADIAN CONTROL PANEL INSTALLATION GUIDE XR150/XR550 SERIES CANADIAN CONTROL PANEL MODEL XR150CAN/XR550CAN Serie CANADIAN INSTALLATION GUIDE INDUSTRY CANADA NOTICE Thi Cla A digital apparatu complie with Canadian ICES-003.

More information

SECTION : FIRE ALARM & DETECTION SYSTEMS

SECTION : FIRE ALARM & DETECTION SYSTEMS SECTION 28 31 10: FIRE ALARM & DETECTION SYSTEMS 1. GENERAL A. This section applies to fire detection/alarm system and carbon monoxide system components and equipment installed during new construction

More information

TELEPHONE: (215) Addendum No. 01. Andrew J. Morrison Elementary School Fire Alarm System Replacement SDP Contract No. B-009 (C) of 2017/18

TELEPHONE: (215) Addendum No. 01. Andrew J. Morrison Elementary School Fire Alarm System Replacement SDP Contract No. B-009 (C) of 2017/18 TE OOL DITRIT O PILADLPIA OOL REORM OMMIION Offce of ptl Poms 0 Noth Bod teet, d loo ute Phldelph, PA 0 TELEPONE: () 00-0 Addedum No. 0 ubject: Aw J. Moso Elemety chool e Alm ystem Replcemet DP otct No.

More information

SECTION ADDRESSABLE FIRE ALARM SYSTEM

SECTION ADDRESSABLE FIRE ALARM SYSTEM SECTION 16723 ADDRESSABLE FIRE ALARM SYSTEM 1 PART 1 GENERAL 1.1 DESCRIPTION A. This section outlines the requirements for the installation, programming and configuration of Addressable Fire Alarm System

More information

INT 69 YF Diagnose. Application. Functional description

INT 69 YF Diagnose. Application. Functional description INT 69 YF Diagnoe Application The motor protector INT69 YF Diagnoe i a univeral and veratile protection unit. For the monitoring of electrical component, variou input for temperature, voltage, leakage/reitance

More information

INSTALLATION GUIDE XR500 SERIES CONTROL PANEL

INSTALLATION GUIDE XR500 SERIES CONTROL PANEL INTALLATION GUIDE XR500 ERIE CONTROL PANEL MODEL XR500, XR500N, XR500E ERIE CONTROL PANEL INTALLATION GUIDE FCC NOTICE This equipment generates and uses radio frequency energy and, if not installed and

More information

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

DIVISION 28 ELECTRONIC SAFETY AND SECURITY 281300 - ACCESS CONTROL A. General DIVISION 28 ELECTRONIC SAFETY AND SECURITY At the beginning of the project, schedule a meeting with the Facilities Access/Maintenance Coordinator with questions and concerns.

More information

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods 1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less,

More information

I.C. Thomasson Associates, Inc. CONSULTING ENGINEERS 2950 KRAFT DRIVE, SUITE 500 NASHVILLE, TN. 37204 PHONE (615) 346-3400 FAX (615) 346-3550 www.icthomasson.com ICT PROJECT # 170647 HODGSON DOUGLAS landscape

More information

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline Moreno Valley Fire Department Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: May 8, 2017 Alarm & Signaling Systems PURPOSE Fire alarm and signaling systems are designed to

More information

Memphis Housing Authority High Rise Fire Alarm Upgrades. Questions from Contractors (Through Addendum #2) Communications Systems, Inc.

Memphis Housing Authority High Rise Fire Alarm Upgrades. Questions from Contractors (Through Addendum #2) Communications Systems, Inc. Memphis Housing Authority High Rise Fire Alarm Upgrades Questions from Contractors (Through Addendum #2) Communications Systems, Inc.: Legend 1. DL - Dome light symbol should be on the tenant emergency

More information

XRSuper6/XR20/XR40 Command Processor TM Panels Installation Guide

XRSuper6/XR20/XR40 Command Processor TM Panels Installation Guide XRuper6/XR20/XR40 Command Processor TM Panels Guide 22/26/42 Zone Burglary/Fire/Access Control Panels with Built-in Communicator 2500 N. Partnership Boulevard pringfield, MO 65803 www.dmpnet.com Digital

More information

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings 1 T Consultant: NOTES, SYMBOLS & ABBREVIATIONS - MECHANICAL Number Description M001 Vestibule 117 LAN/IT Coffee 115 116 Mail Room 118 114 113 112 Scanning 119 Open Office 101 FIRST FLOOR PLAN - MECHANICAL

More information

Fibrafort EXCELLENCE IN EVERY DETAIL.

Fibrafort EXCELLENCE IN EVERY DETAIL. EXCELLENCE IN EVERY DETAIL. Excluive product innovation are Fibrafort propriety. The manufacturer reerved itelf the right to make any change on the product without any warning. July/2015. Fibrafort 320

More information

PANIC EXIT HARDWARE DX-200 Serie

PANIC EXIT HARDWARE DX-200 Serie PANIC EXIT HARDWARE DX-200 Serie Explanation of European tandard The tandard EN 1125 and EN 179 were created at the European level with the acceptance and cooperation of the Dutch tandard committee. The

More information

FACILITIES PLANNING AND CONSTRUCTION

FACILITIES PLANNING AND CONSTRUCTION ACILITIES PLANNING AND CONSTRUCTION Sheet List Table Sheet Number Sheet Title 0.0 CPR COVER E0.1 CPR IRE ALARM SYMBOL LEGEND RISER AND NOTES E1.1 CPR IRST LOOR DEMOLITION PLAN - IRE ALARM E1.2 CPR SECOND

More information

GARCIA GALUSKA DESOUSA Consulting Engineers

GARCIA GALUSKA DESOUSA Consulting Engineers L#57297 /Page 1/July 21, 2017 ELECTRICAL SYSTEMS NARRATIVE REPORT The following is the Electrical Systems narrative, which defines the scope of work and capacities of the Power and Lighting systems, as

More information

FREE & FORCED CONVECTION HEAT TRANSFER

FREE & FORCED CONVECTION HEAT TRANSFER FREE & FORCED CONVECION HEA RANSFER Objective he objective of thi experiment are: (1) o demontrate the relationhip between power input and urface temperature in free convection (2) o demontrate the relationhip

More information

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III

COUNTY OF KINGS KINGS COUNTY JAIL EXPANSION PHASE III SECTION 28 3111 - DIGITAL ADDRESSABLE FIRE ALARM SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED SYMBOLS AND ABBREVIATIONS ABBREVIATIONS GENERAL NOTES LINE TYPE LEGEND CIRCUITS TELECOMMUNICATION SYSTEM ING EQUIPMENT POWER DEVICES FIRE ALARM SYSTEM NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

More information

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR SECTION 08734 COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR Display hidden notes to specifier by using Tools / Options / View / Hidden Text. PART 1 GENERAL 1.1 SECTION INCLUDES A. Overhead

More information

INSTALLATION GUIDE XR100 SERIES CONTROL PANEL

INSTALLATION GUIDE XR100 SERIES CONTROL PANEL INTALLATION GUIDE XR100 ERIE CONTROL PANEL MODEL XR100 ERIE CONTROL PANEL INTALLATION GUIDE FCC NOTICE This equipment generates and uses radio frequency energy and, if not installed and used properly in

More information

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM SECTION 28 3111 DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Fire-alarm control unit. 2. Manual fire-alarm boxes. 3. System smoke detectors. 4. Heat detectors.

More information

SHEET 4 OF 12 CONCEPTUAL LANDSCAPE NOTES AND DETAILS LEGEND CANOPY TREE ORNAMENTAL TREE SHRUB BED

SHEET 4 OF 12 CONCEPTUAL LANDSCAPE NOTES AND DETAILS LEGEND CANOPY TREE ORNAMENTAL TREE SHRUB BED Please ensure the pages are numbered correctly. Page 4 of 6 FALLBROOK - 140TH & COLORADO CONCEPTUAL ITE PLAN / ODP A PARCEL OF LAND LOCATED IN THE NORTH ONE-HALF OF ECTION 24, TOWNHIP 1 OUTH, RANGE 68

More information

Bulk Handling of Paraplex and Plasthall Plasticizers

Bulk Handling of Paraplex and Plasthall Plasticizers Bulk Handling of Paraplex and Plathall Platicizer Buying and handling platicizer in bulk i attractive becaue the reulting cot per pound i alway lower than the cot in drum quantitie. Other advantage include

More information

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School ELECTRICAL SYSTEMS ASSESSMENT Hanover High School ELECTRICAL DISTRIBUTION SYSTEM:?? The existing electrical service consists of an underground primary service originating at a utility pole on Cedar Street,

More information

Sinumerik 808D Service Guide

Sinumerik 808D Service Guide Training manual Sinumerik 808D Service Guide Verion 2013-01 Note Service guide 808D Lit For Service cae of hardware Go to page 7 Service cae of For Go to page 23 PLC alarm For Service cae of NC program

More information

NYC Department of Education

NYC Department of Education Asset: P.S. 5 - BROOKLYN, 820 HANCOCK STREET, New York, 11233 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2018-05-25 8:54 AM 2018-06-04 10:18 AM Asset Data Type of Service Does Interactive

More information

NYC Department of Education

NYC Department of Education NYC Department of Education Building Assessment Survey 2017-2018 Asset: P.S. 314 - BROOKLYN, 330 59 STREET, New York, 11220 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2018-04-23

More information

INSTALLATION GUIDE XR ZONE COMMAND PROCESSOR PANEL

INSTALLATION GUIDE XR ZONE COMMAND PROCESSOR PANEL INTALLATION GUIDE XR200 242-ZONE COMMAND PROCEOR PANEL MODEL XR200 COMMAND PROCEOR INTALLATION GUIDE FCC NOTICE This equipment generates and uses radio frequency energy and, if not installed and used properly

More information

General. Mode of operation and application. Input

General. Mode of operation and application. Input Dataheet for SITRANS P DSIII / P410 GAUGE PRESSURE SITRANS P DS III / P410, HART,4-20 ma tranmitter for preure 7MF40331BA101NC6 General Manufacturer Supplier Product deignation Brand name Type deignation

More information

BSD Technical Standard. Division 28: Electronic Safety & Security

BSD Technical Standard. Division 28: Electronic Safety & Security Division 28: Electronic Safety & Security I. PURPOSE This Technical Standard is a narrative describing Beaverton School District s (BSD s) basis of design for electronic safety and security in BSD facilities.

More information

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control

Fire Control Panels. Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control MANUAL RELEAE - IDNET IN + +IDNET IN - R E D N A C + N A C - C O IL U P E R V I IO N MOD U L E ( 2 A MP ) 2 8-9 4 6 IN T A L L A T ION IN T R U C T ION 5 7 4-4 3 7 R E V Y E L MA IN T A IN /4 " E P A R

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 8/10/11 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Is low voltage cable allowed to be run through drilled

More information

The following information shall become and form part of the contract documents.

The following information shall become and form part of the contract documents. October 4, 206 To: Attention: Re: All Bidders All Bidders JCBE Gymnasium HVAC Upgrades BC#: 206433 Edmonds Project No.: BHM6090 All bidders, The following information shall become and form part of the

More information

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings. DIVISION 26 ELECTRICAL SECTION 26 27 26 PART 1 GENERAL 1.01 DESCRIPTION A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings. B. Specialty switches and outlets

More information

Installation Instructions

Installation Instructions Electric Heater Kit For use with GB, GP and GT eries Geothermal Heat Pumps KWAEH0101N05 KWAEH0101N10 KWAEH0101F15 KWAEH0101F20 Installation Instructions NOTE: Read the entire instruction manual before

More information

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics.

Standard of Practice - Fire Alarm Systems. NOTE: Significant revisions or additions to the previous standards are highlighted in italics. A28.1 Standard of Practice - Fire Alarm Systems NOTE: Significant revisions or additions to the previous standards are highlighted in italics. OBJECTIVE OF STANDARD To provide compliant smart addressable

More information

SECTION INTRUSION DETECTION

SECTION INTRUSION DETECTION (NOTE TO DESIGNER: These Specifications are basic minimum criteria to be met in preparing the final specifications for this section, which is the responsibility of the Designer.) SECTION 28 16 00 INTRUSION

More information

SECTION DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM SECTION 283111 DIGITAL, ADDRESSABLE FIRE ALARM PART 1 - GENERAL 1.1 GENERAL A. This Section includes the following: 1. Fire-alarm control panel. 2. Manual fire-alarm boxes. 3. Smoke detectors. 4. Heat

More information

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

DIVISION 28 ELECTRONIC SAFETY AND SECURITY DIVISION 28 ELECTRONIC SAFETY AND SECURITY CENTRALLY MANAGED ELECTRONIC ACCESS CONTROL, VIDEO SURVEILLANCE, AND INTRUSION ALARM SYSTEMS 1. All questions on equipment approvals in this section shall be

More information

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE The University of Arizona has implemented a Keyless Access and Security System program to provide a cost effective, efficient, and maintainable means

More information

Building Technologies Division Infrastructure & Cities Sector

Building Technologies Division Infrastructure & Cities Sector Ditribuitor: FLAE POWER SRL 021-3121727 ; 0744-340566 contact@arzatoare.ro ; www.arzatoare.ro 7 106 Burner control LE39... Burner control for the uperviion of 1- or 2-tage ga or ga / oil burner of mall

More information

El Reno Fire Department Fire Alarm Plan Review Worksheet

El Reno Fire Department Fire Alarm Plan Review Worksheet El Reno Fire Department Fire Alarm Plan Review Worksheet This Fire Alarm Plan Review Checklist is provided as a guide to assist with your Fire Alarm Plan Review Submittal requirements. Please contact us

More information

STUDY AND TEST MATERIAL FOR THE. FA2 and FA4 ASSESSMENTS. (Fire Alarm On-Site and Business Cert. Holder) June 14, 2017

STUDY AND TEST MATERIAL FOR THE. FA2 and FA4 ASSESSMENTS. (Fire Alarm On-Site and Business Cert. Holder) June 14, 2017 STUDY AND TEST MATERIAL FOR THE FA2 and FA4 ASSESSMENTS (Fire Alarm On-Site and Business Cert. Holder) June 14, 2017 This document contains sample questions to help participants study for the FA2 and FA4

More information

CM-800 CM-900 OPERATION, INSTALLATION AND SERVICE MANUAL. Innovations in Communications since 1955 FEATURES

CM-800 CM-900 OPERATION, INSTALLATION AND SERVICE MANUAL. Innovations in Communications since 1955 FEATURES Innovations in Communications since 1955 TM CM-800 CM-900 OERTIO, ITLLTIO ERVICE MUL LICTIO The CM800/CM900 (CM-800, CM-900) Emergency Call ignaling ystem is designed for elderly housing, retirement facilities

More information

Temperature and humidity ranges. Operating the GC within the recommended ranges insures optimum instrument performance and lifetime.

Temperature and humidity ranges. Operating the GC within the recommended ranges insures optimum instrument performance and lifetime. Temperature and humidity range Operating the GC within the recommended range inure optimum intrument performance and lifetime. Recommended temperature range 20 to 27 C 5 to 40 C Temperature range Recommended

More information

NYC Department of Education

NYC Department of Education NYC Department of Education Building Assessment Survey 2017-2018 Asset: PS 152 ANNEX -BROOKLYN, 1087 OCEAN AVENUE, New York, 11210 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2018-03-20

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Alarm System Plan Review 2009 International Fire Code and 2010 NFPA 72 Date of Review // BLD201 - Project Address: Project Name: _ Professional

More information

SI 3080 / SI 3100 / SI 3200

SI 3080 / SI 3100 / SI 3200 SI 3080 / SI 3100 / SI 3200 Mini pump for air conditioner up to 10 kw (SI 3080 & SI 3100) and up to 20 kw (SI 3200) SILENCIEUSES SILENT o Integral quick / connector plug Anti-vibration mount SI 3080 SI

More information

NYC Department of Education

NYC Department of Education Building Assessment Survey 2017-2018 Asset: HS FOR MATH, SCI & ENGINEERING-M, 240 CONVENT AVENUE, New York, 10031 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2017-12-20 11:37 AM 2018-01-09

More information

INSTALLATION OF ACCESS FLOOR SYSTEMS IN GENERAL OFFICE AREA AND COMPUTER ROOM

INSTALLATION OF ACCESS FLOOR SYSTEMS IN GENERAL OFFICE AREA AND COMPUTER ROOM INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: Mech Code 601 Effective: 2-07-79 DOCUMENT NO. P/BC 2002-018 Revised: 9-25-03 Previously Issued As: RGA 2-79, MGD101 INSTALLATION OF ACCESS FLOOR

More information

InstallatIon GuIde XR500FC series Command PRoCessoR Panel

InstallatIon GuIde XR500FC series Command PRoCessoR Panel Installation Guide XR500FC eries Command Processor Panel MODEL XR500FC, XR500NFC COMMAND PROCEOR INTALLATION GUIDE FCC NOTICE This equipment generates and uses radio frequency energy and, if not installed

More information

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016

Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting. Prepared Especially for : OSFM TEC 2016 Fire Alarm Acceptance Testing & On-Going Maintenance with The Joint Comm. Standards / Reporting Prepared Especially for : OSFM TEC 2016 Acceptance Testing 11-2008 Agenda Before you begin Completing the

More information

SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003

SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003 SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003 No. Discipline Sent to Name Item Date Noted Date Resolved How item was resolved SCO # 1Punch listed items were noted below on

More information

F F AFF AC A ANN AA BKR LC CL 2 CF(P OR L) CR(P OR L) CH COPT COND CDT C( ) CC( ) CPT CR( ) I/I I/P CT DP DC D DPDT ET ET EUH EWC EWF FO F FT F FR FR GP G GRD GFI A ABOVE FINIHED FLOOR ALTERNATING CURRENT

More information

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION FIRE ALARM SYSTEM OSU PROJECT NO. 30-04-15 PAGE 1 PART 1 GENERAL 1.1 WORK INCLUDED A. Provide all labor, materials, and equipment required to provide a complete and operating system of manual and automatic detection devices,

More information

NYC Department of Education

NYC Department of Education NYC Department of Education Building Assessment Survey 2017-2018 Asset: P.S. 56 - STATEN ISLAND, 250 KRAMER AVE., New York, 10309 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2017-10-20

More information

Building Technologies Division

Building Technologies Division 7 154 Burner control LMO39... Burner control for the uperviion of 1- or 2-tage oil burner of mall to medium capacity, with or without fan in intermittent operation. The LMO39 and thi Data Sheet are intended

More information

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY

Inspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY FIRE ALARM INSPECTION AND TESTING SUMMARY PAGE PER 2013 NFPA 72 Inspector: Jim Smith Test Date: 5/22/2014 PROPERTY INFORMATION Name of Property: Windsor Tower Owner of Property: Jim Gibbs Properties Address:

More information

NYC Department of Education

NYC Department of Education NYC Department of Education Building Assessment Survey 2017-2018 Asset: P.S. 86 - BROOKLYN, 220 IRVING AVENUE, New York, 11237 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2017-11-14

More information

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

Smoke Detector Activation of any smoke detector shall start the alarm verification mode. Description: The purpose of the section is to provide the UMCP Design Standards for the design and implementation of Fire Alarm Systems at the UMCP campus. Related Sections: TBD Effective Date: July 10,

More information

Port of Portland Conveying Equipment Guidelines

Port of Portland Conveying Equipment Guidelines Role: Consultant for the Port Design Guidelines Port of Portland Conveying Equipment Guidelines ELEVATOR, ESCALATOR, AND MOVING WALK DESIGN OVERVIEW The Division 14 specification sections include appropriate

More information

Electronic Safety and Security

Electronic Safety and Security 28 Electronic Safety and Security NOTE: This is a new section, which includes content from previous sections of the KU Design Standards, along with appropriate revisions and updates. Significant revisions

More information

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices. SECTION 16470 PANELBOARDS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16120 - Wire and Cable. 3. 16475 - Overcurrent Protective Devices. 1.02 SYSTEM DESCRIPTION A. Performance

More information

SOUTHVIEW MEDICAL CENTER

SOUTHVIEW MEDICAL CENTER PROJECT TITLE: SOUTHVIEW MEDICAL CENTER ENTRANCE VESTIBULE 1997 Miamisburg Centerville Rd. Dayton, Ohio DRAWING INDEX: STRUCTURAL ARCHITECTURAL JUNE 26, 2014 Bulletin #1 - September 12, 2014 AREA OF WORK

More information

CM800/CM900 Emergency Call Systems IL514 Installation & Operating Instructions

CM800/CM900 Emergency Call Systems IL514 Installation & Operating Instructions CM800/CM900 Emergency Call ystems IL514 Installation & Operating Instructions CM800/CM900 Emergency Call ystems Rev. 16 06/2016 Contents ystem Installation... 1 Installation rocedure.........................1

More information