Residential Fire Sprinkler Inspection
|
|
- Vincent King
- 5 years ago
- Views:
Transcription
1 Residential Fire Sprinkler Inspection Hickory, NC Charleston, SC Greensboro, NC Columbia, SC Raleigh, NC Greenville, SC Charlotte, NC Atlanta, GA Tampa, FL Date 7/7/6 Annual Quarterly PO Box 9489 Hickory, NC 8603 FED EF0009 FPC-0004 CFC4900 # of wet systems: 7 Company: Oakland Mill Apartments # Antifreeze: Address: 0 Nelson Dr. # of BFPs Fire 8 Dom NC 809 Inspector: Adam Sims Phone: (704) -46 Contact: Cheryl Pate License #: 363 NERAL INFORMATION (GI) No N/A (SI) - CONTINUED No N/A. Are all dwelling units accessible for visual inspection? 0. Hangers & Seismic bracing OK?. Does the building appear to be fully sprinklered?. Antifreeze Systems tested? 3. Systems in service without modification since the last. Relief valves on system OK? inspection? 3. FDC swivels, gaskets, & caps in place and OK? 4. Spare head box with heads and wrench securely monitored? 4. FDC signs in place? 5. FDC equipped with ball drip? 5. Stock/storage a minimum of 8 below sprinkler head & ceiling tiles in place? 6. Sprinkler system main drain test completed? 6. Gauges condition good & less than 5 years old? ALARM INFORMATION (AI) No N/A Last calibration date: 03. Was the WMG or Electric bell tested & OK? 7. Wet system areas adequately heated?. Central Station flow alarm tested & OK? 8. Inspection of common areas only. 3. Central Station tamper tested & OK? VALVE INFORMATION (VI) No N/A 4. Alarm devices free from physical damage & all electrical connections secure?. Are all main control valves open? 5. Alarm trim, and valves OK & set properly?. Main control valves in good condition and identified? 6. Inspectors test connection(s) opened and flowed? 3. Are control valves secure? (Record pg. ) BFP INFORMATION (BI) No N/A 4. Are all control valves accessible & free from leaks?. Backflow devices pressure tested? 5. 5 year Internal check valve inspections due.. Backflow device forward flow tested? 6. Are all control valves provided with the proper controls? Sprinklers 7. All control valves operated through full range & returned to Make: normal position? Model: Globe gl Valves lubricated, as needed? Year: 03 SPRINKLER & PIPING INFORMATION (SI) No N/A Temp: 55/75. Are all sprinklers unobstructed? Finish: White. Sprinklers & escutcheon plates free of corrosion, tape, paint, & physical damage? QR/SR: Qr 3. Are all sprinklers less than 50 years old? K Factor: 4. Are all QR Sprinklers less than 0 years old? Thread: / 5. Are escutcheon plates OK? Esch: Sem rec 6. Riser in good condition & accessible? GB/Sldr: Gb 7. Hydraulic nameplate in place & OK? Antifreeze Systems(s) 8. System ID securely attached & legible? Location Number of Heads Temperature 9. Pipe in good condition, free of damage & obstructions, and leaks? Main Drain & Alarm Test System No: System Size: Static Pressure (psi): Residual Pressure (psi): Static Pressure (psi): Local Alarm OK (Y / N):, Locked, or Sealed No. of s Accessible (Y / N) Location (F=FDC, R=Riser) N F N F N F N F N F N F N F All Systems left in Service Inspections Tags In Place Inspection Results Discussed with Property Representative 7/7/6 Property Representative: Inspector s Signature: Date: 0
2 Hickory, North Carolina 8603 Hickory, NC Greensboro, NC Raleigh, NC Charlotte, NC Charleston, SC FED Columbia, SC FPC-0004 Greenville, SC Atlanta, GA Tampa, FL DATE: NFPA #7 FIRE ALARM INSPECTION/ENGINEERED SYSTEM INSPECTION REPORT EF0009 CFC /07/06 :00am EDT CUSTOMER: Oakland Mill Apartments ADDRESS: 0 Nelson Dr. CITY/STATE: PHONE: (704) -46 JOB #: NC ZIP: 809 Annual Semi Annual Other Monitoring Company ME: Oakland Mill Apartments PHONE: Building # Alarm Mfg. Model Manual Stations Smoke Detectors Heat Detectors Duct Detectors Waterflow Switches Switches Horn/Strobes Horns Only Strobes Only Door Holders Elevator Recall Battery Type Battery Date Panel Keys Pullstation Keys Clubhouse Vs 5 Na Na Na Na 6 V 8Amp 03 Bldg Vs v 8 amp 03 Bldg Vs v 8amp 03 Bldg 3 Vs v 8 amp 03 Notes or Deficiencies: 6- volt 8amp due for replacement X Date: Technician certifies alarm system was inspected. Deficiencies are noted. (If Applicable) /07/06 :00am EDT X Date: Customer has been informed of any deficiencies and accepts responsibility for verifying alarm signals to monitoring Co. (If Applicable)
3 Hickory, North Carolina 8603 Hickory, NC Greensboro, NC Raleigh, NC Charlotte, NC Charleston, SC FED Columbia, SC FPC-0004 Greenville, SC Atlanta, GA Tampa, FL DATE: NFPA #7 FIRE ALARM INSPECTION/ENGINEERED SYSTEM INSPECTION REPORT EF0009 CFC /07/06 :00am EDT CUSTOMER: Oakland Mill Apartments ADDRESS: 0 Nelson Dr. CITY/STATE: PHONE: (704) -46 JOB #: NC ZIP: 809 Annual Semi Annual Other Monitoring Company ME: Oakland Mill Apartments PHONE: Building # Alarm Mfg. Model Manual Stations Smoke Detectors Heat Detectors Duct Detectors Waterflow Switches Switches Horn/Strobes Horns Only Strobes Only Door Holders Elevator Recall Battery Type Battery Date Panel Keys Pullstation Keys Bldg 4 Vs v 8amp 03 Bldg 5 Vs v 8amp 03 Bldg 6 Vs v 8amp 03 Bldg7 Vs v 8amp 03 Notes or Deficiencies: X Date: Technician certifies alarm system was inspected. Deficiencies are noted. (If Applicable) /07/06 :00am EDT X Date: Customer has been informed of any deficiencies and accepts responsibility for verifying alarm signals to monitoring Co. (If Applicable)
4 PO Box 9489 Hickory, NC 8603 FED EF0009 FPC-0004 CFC4900 Fire Sprinkler/Alarm Inspection Hickory, NC Charleston, SC Greensboro, NC Columbia, SC Raleigh, NC Greenville, SC Charlotte, NC Atlanta, GA Tampa, FL Oakland Mill Apartments Company: 07/07/06 :00am Date Annual Quarterly Monthly No hydraulic nameplates installed at risers 7 total. Comments and Recommendations Roger Miller Inspector s Signature Customer Acknowledgment Print Name & Title
5 070 7th St. Ct. SE Phone: Fax: Address of Property: 0 Nelson Dr. Meter Model & Number: NC 809 Type of Service: DOM IRRIG. F.L. Combo (DOM/F.L.) Type of Assembly: RP DC PVB Size of Assembly: Model: 007mqt Serial Number: Location of Assembly: Bldg riser room Containment (at meter) or Isolation (at branch) Line Pressure: PSI: Check Valve # Relief Valve Check Valve # Pressure Vacuum Breaker.0.8 Shut Off # Held Tight Shut Off # Held Tight Assembly: PASSED FAILED NOTE: All repairs must be completed within (0) ten days. Kit: DIFF DUPL ELEC Manufacturer: TESTER: CERT. Adam NO: TIME/DATE: CALIBRATION 05-cm DATE: 5--06
6 070 7th St. Ct. SE Phone: Fax: Address of Property: 0 Nelson Dr. Meter Model & Number: NC 809 Type of Service: DOM IRRIG. F.L. Combo (DOM/F.L.) Type of Assembly: RP DC PVB Size of Assembly: Model: 007mqt Serial Number: Location of Assembly: Bldg riser room Containment (at meter) or Isolation (at branch) Line Pressure: PSI: Check Valve # Relief Valve Check Valve # Pressure Vacuum Breaker.8.0 Shut Off # Held Tight Shut Off # Held Tight Assembly: PASSED FAILED NOTE: All repairs must be completed within (0) ten days. Kit: DIFF DUPL ELEC Manufacturer: TESTER: CERT. Adam Sims NO: TIME/DATE: CALIBRATION 05-cm DATE: 5--06
7 070 7th St. Ct. SE Phone: Fax: Address of Property: 0 Nelson Dr. Meter Model & Number: NC 809 Type of Service: DOM IRRIG. F.L. Combo (DOM/F.L.) Type of Assembly: RP DC PVB Size of Assembly: Model: Serial Number: Location of Assembly: Bldg 3 riser room Containment (at meter) or Isolation (at branch) Line Pressure: PSI: Check Valve # Relief Valve Check Valve # Pressure Vacuum Breaker.0.0 Shut Off # Held Tight Shut Off # Held Tight Assembly: PASSED FAILED NOTE: All repairs must be completed within (0) ten days. Kit: DIFF DUPL ELEC Manufacturer: TESTER: CERT. Adam Sims NO: TIME/DATE: CALIBRATION 05-cm DATE: 5--06
8 070 7th St. Ct. SE Phone: Fax: Address of Property: 0 Nelson Dr. Meter Model & Number: NC 809 Type of Service: DOM IRRIG. F.L. Combo (DOM/F.L.) Type of Assembly: RP DC PVB Size of Assembly: 8" Model: 909 Serial Number: 673 Location of Assembly: In hotbox beside bldg 0 Containment (at meter) or Isolation (at branch) Line Pressure: 45 PSI: Check Valve # Relief Valve Check Valve # Pressure Vacuum Breaker Shut Off # Held Tight Shut Off # Held Tight Assembly: PASSED FAILED NOTE: All repairs must be completed within (0) ten days. Kit: DIFF DUPL ELEC Manufacturer: TESTER: CERT. Adam Sims NO: TIME/DATE: CALIBRATION 05-cm DATE: 5--06
9 070 7th St. Ct. SE Phone: Fax: Address of Property: 0 Nelson Dr. Meter Model & Number: NC 809 Type of Service: DOM IRRIG. F.L. Combo (DOM/F.L.) Type of Assembly: RP DC PVB Size of Assembly: Manufacturer: Wilkins Model: 375 Serial Number: A9754 Location of Assembly: In hotbox left of bldg 4 Containment (at meter) or Isolation (at branch) Line Pressure: 45 PSI: Check Valve # Relief Valve Check Valve # Pressure Vacuum Breaker Shut Off # Held Tight Shut Off # Held Tight Assembly: PASSED FAILED NOTE: All repairs must be completed within (0) ten days. Kit: DIFF DUPL ELEC Manufacturer: TESTER: CERT. Adam Sims NO: TIME/DATE: CALIBRATION 05-cm DATE: 5--06
10 070 7th St. Ct. SE Phone: Fax: Address of Property: 0 Nelson Dr. Meter Model & Number: NC 809 Type of Service: DOM IRRIG. F.L. Combo (DOM/F.L.) Type of Assembly: RP DC PVB Size of Assembly: Model: 007mqt Serial Number: Location of Assembly: Bldg 4 riser room Containment (at meter) or Isolation (at branch) Line Pressure: PSI: Check Valve # Relief Valve Check Valve # Pressure Vacuum Breaker.0.0 Shut Off # Held Tight Shut Off # Held Tight Assembly: PASSED FAILED NOTE: All repairs must be completed within (0) ten days. Kit: DIFF DUPL ELEC Manufacturer: TESTER: CERT. Adam Sims NO: TIME/DATE: CALIBRATION 05-cm DATE: 5--06
11 070 7th St. Ct. SE Phone: Fax: Address of Property: 0 Nelson Dr. Meter Model & Number: Na NC 809 Type of Service: DOM IRRIG. F.L. Combo (DOM/F.L.) Type of Assembly: RP DC PVB Size of Assembly: Model: 007mqt Serial Number: Location of Assembly: Bldg 5 riser room Containment (at meter) or Isolation (at branch) Line Pressure: PSI: Check Valve # Relief Valve Check Valve # Pressure Vacuum Breaker.8.8 Shut Off # Held Tight Shut Off # Held Tight Assembly: PASSED FAILED NOTE: All repairs must be completed within (0) ten days. Kit: DIFF DUPL ELEC Manufacturer: TESTER: CERT. Adam Sims NO: TIME/DATE: CALIBRATION 05-cm DATE: 5--06
SPRINKLER SYSTEM DRY WET
Seattle Fire Department Confidence Test Report (use one form per sys.) 206-386-1448 Confidence Testing Officer 206-615-1068 (fax) 206-233-7219 Red Tag Hotline SPRINKLER SYSTEM DRY WET Status Given CONFIDENCE
More informationAnnual Water-Based Fire Protection Systems Inspection
Annual Water-Based Fire Protection Systems Inspection 2425 Amann Drive Belleville, IL 62220 www.boyerfire.com Phone: 618-222-1500 Fax: 618-222-1502 Inspector: Steve Love Inspection date: 04/03/17 Inspection
More informationAnnual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System
Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System Building/Business Name: Address of Property: Inspector Name: Joe Price THE CORNERSTONE 1425 NE 7TH AVENUE PORTLAND OR Date
More informationFIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT
SANTA MONICA FIRE DEPARTMENT Fire Prevention Division 333 Olympic Drive 2 nd Floor Santa Monica, CA 90401 310-458-8915 / Fax 310-395-3395 FIVE YEAR AUTOMATIC FIRE EXTINGUISHING SYSTEMS CERTIFICATION REPORT
More informationADDENDUM #1 ITB# Fire Protection Maintenance Services Responses to Clarification Questions 10/06/2015
ADDENDUM #1 ITB# 2015-09-002 Fire Protection Maintenance Services Responses to Clarification Questions 10/06/2015 1. Building #222, The UPS Building, has one (1) dry Sprinkler riser, valve. (This is a
More informationNew Construction Fire Inspection Process
New Construction Fire Inspection Process This document is intended to provide the Owner, Designer, and/or Contractor of new construction with an outline of required fire inspections and with the specific
More informationInspection Report Nursing Home Life Safety Code Section 4 - Annual Fire Alarm Testing and Maintenance. For
Inspection Report Nursing Home Life Safety Code Section 4 - Annual Fire Alarm Testing and Maintenance For CarDon & Associates Fall Creek Health & Living Prepared by: L.Thompson/T.Roe 7/31/2014 Report Length:
More information2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7
WET SPRINKLER Monthly Wet Sprinkler 2-SUPPRESSION REQUIREMENTS - CODE REQUIRED INSPECTIONS TEST Page 1 of 7 VISUALS [per NFPA 25-1998 ed] 1. Gauge (Ck for Condition, Normal Pressure) [per 2-2.4.1] 2. Valves
More informationOxnard Fire Department 360 W. Second Street Oxnard, CA (805) Fax (805)
Oxnard Fire Department 360 W. Second Street Oxnard, CA 93030 (805) 385-7722 Fax (805) 385-8009 FIVE YEAR CERTIFICATION REPORT Service and maintenance report for automatic fire extinguishing systems, including
More informationC. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.
SECTION 218800 - FIRE PROTECTION 1. GENERAL A. Provisions of Division 1, GENERAL REQUIREMENTS, and Section 230000, MECHANICAL GENERAL CONDITIONS, and Section 230050, SEISMIC PROTECTION are a part of this
More information109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:
109-B Concord Drive Casselberry, FL 32707 407.830.6500 DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72 Pg 1 of 4 Equity One 11180600 Owner/Representative: WO#: _Customer#: 1550 NE Miami Garden Dr
More informationSkilled Healthcare Documentation Requirements Life Safety and Fire Protection
DATE OF EVALUATION: FACILITY NAME: FACILITY ADDRESS: ADMINISTRATOR: MAINTENANCE DIRECTOR: All required documentation must be written and saved for at least 2 years and some documentation may be required
More informationService Requirements SEMI- ANNUAL ANNUALLY OTHER REF. REQUIREMENT
58 Fire protection equipment requires care and maintenance at scheduled intervals to assure it will operate properly and safely when needed. Only personnel who are trained and qualified to maintain the
More informationQuick Guide for Fire Sprinkler Inspection Requirements Key Deficiencies with NFPA References NFPA & NFPA 13/
Quick Guide for Fire Sprinkler Inspection Requirements Key Deficiencies with NFPA References NFPA 25 2017 & NFPA 13/72 2016 The purpose of this guide is to help you determine if the system will work as
More informationReport of Inspection/Test
Report of Inspection/Test 4616-2 West Howard Lane Suite 4 Austin, Texas 78727 Phone: 512-833-8 Fax: 512-833-7862 Inspection Type: Pump - Annual Inspection Date: 2/24/217 1::2 AM Building Address:88 South
More informationSprinkler Inspection Certificate
Sprinkler Inspection Certificate For New Dimensions High School 4900 Old Pleasant Hilll Road Kissimmee, FL 34746 Tested to NFPA 25 Standards This Inspection was performed in accordance with applicable
More informationInspection of Fire Sprinkler Systems. NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems
Inspection of Fire Sprinkler Systems NFPA 25, Inspection, Testing & Maintenance of Water Based Fire Protection Systems Objective To familiarize Facility Managers with the process of routine inspection
More informationUSAutomatic Sprinkler Corporation
Inspection Report Information For CITY OF WESTFIELD - PUBLIC SAFETY Prepared by: T.Hughes, C.Gibbs a fire protection company Sheet 1 of 2 Phone: (317) 573-8160 Fax: (317) 573-8161 110370 REPORT OF INSPECTION
More informationFIRE SPRINKLER SYSTEMS POLICY
FIRE SPRINKLER SYSTEMS POLICY Revised 1/1/17 DESIGN AND SUBMITTAL REQUIREMENTS All new and existing fire sprinkler systems within the jurisdiction of the City Fire Department shall meet all of the applicable
More informationMAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS
MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS Introduction When properly installed and maintained, automatic fire sprinkler systems have proven to be the most effective means for protecting life and
More informationFIRE SPRINKLER SYSTEMS POLICY
FIRE SPRINKLER SYSTEMS POLICY VERSION 1.012/2015 FIRE SPRINKLER SYSTEMS Design and Submittal requirements All new and existing fire sprinkler systems within the jurisdiction of the City of San Mateo Fire
More informationNFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,
NFPA CODE TESTING & INSPECTION Requirements & Recommendations for Licensed Florida Hospitals, Ambulatory Surgery Centers, ICF/IID Healthcare, & In-patient Hospice Facilities per NFPA Life Safety Code 101
More informationEnvironmental Health & Safety
Environmental Health & Safety Oklahoma State University FIRE SPRINKLER SYSTEM STANDARD Environmental Health and Safety University Health Services Suite 002 Stillwater, OK 74078 (405) 744-7241 www.ehs.okstate.edu
More informationGlobal Property. SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:
Global Property SEMIANNUAL FIRE PROTECTION EQUIPMENT INSPECTION REPORT Plant: Date of Inspection Location: Inspected By: Reviewed By CONTROL VALVES (If Valves are Not Locked Open or Electronically Supervised
More informationMONTECITO FIRE PROTECTION DISTRICT
Section 5a MONTECITO FIRE PROTECTION DISTRICT FIRE PROTECTION PLAN Residential Automatic Fire Sprinkler System Installations I Automatic Fire Sprinkler System Standards 1. Definition and Standard: An automatic
More informationSystem Test Report CLEAN AGENT
City of Black Hawk Fire Department 196 Clear Creek Street PO Box 68 Black Hawk, CO 80422-068 Office 303-582-0426 Fax 303-582-2229 www.cityofblackhawk.org System Test Report CLEAN AGENT Occupancy Information
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS Address: Permit #: Inspector: Date Inspected: Status: Inspector: Date Inspected: Status: A-Approved;
More informationUBC Technical Guidelines Section Edition Fire Protection General Requirements Page 1 of 6
Page 1 of 6 1.0 GENERAL 1.1 Related UBC Guidelines.1 Section 20 00 05 Mechanical - General Requirements.2 Section 22 05 00 Plumbing - General Requirements.3 UBC Standard Fire Hydrant Drawings.4 Section
More informationNFPA Edition Update
NFPA 13 2013 Edition Update Session Agenda A2012 Code Cycle NFPA 13 Code Development Changes to NFPA 13 (NFPA 24) What Didn t Happen Next Steps 2 A2012 Code Cycle 800+ Proposal 500+ Comments TCC Meeting
More informationFIRE ALARM APPLICATION CITY OF MADISON HEIGHTS
FIRE ALARM APPLICATION CITY OF MADISON HEIGHTS www.madison-heights.org COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION 300 W. THIRTEEN MILE RD. MADISON HEIGHTS, MICHIGAN 48071 (248) 583-0831 FAX (248)
More informationSprinkler Permit Applications
REQUIREMENTS FOR NFPA 13 SYSTEM Building Inspections Sprinkler Permit Applications A complete application for a Sprinkler Permit will comply with the requirements of Chapter 8 of NFPA 13. Hydraulic calculations
More informationFinal EC Inspection Report 03/2010
2491 Alluvial Avenue, Suite 59 Clovis, California 93611 Tel: (559)392-2838 - Fax: (559)325-7599 Contractor License #933910 (C-10/C-16) Final EC.02.03.05 Inspection Report 03/2010 This Final Report Covers
More informationFire Alarm and Life Safety System Inspection Certificate
Fire Alarm and Life Safety System Inspection Certificate For City of Rock Hill 757 S. Anderson Rd Rock Hill, AC 29730 Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable
More informationMINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry
MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Fire Alarm Systems Plan Review Checklist Date: Permit Number: Business Name: Address: Fire Alarm System Submittal
More informationFire Sprinkler System Design and Installation Requirements
Fire Sprinkler System Design and Installation Requirements The Park City Fire Service District (PCFD) and Park City Municipal Corporation (PCMC) have made the following amendments to the State of Utah
More informationGlobal Property. QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Date of Inspection Location:
Global Property QUARTERLY FIRE PROTECTION EQUIPMENT INSPECTION REPORT Plant: Date of Inspection Location: Inspected By: Reviewed By CONTROL VALVES (If Valves are Not Locked Open or Electronically Supervised
More informationMINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review
MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Plan Review Minooka Fire Protection District Maintaining Your Fire Safety Systems Fire continues to be a major threat
More informationAUTOMATIC FIRE SPRINKLER SYSTEMS
MCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE AUTOMATIC FIRE SPRINKLER SYSTEMS These guidelines are to be followed when a business, facility or organization installs an automatic fire sprinkler system
More informationMontgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040
Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040 SPRINKLER SHOP DRAWINGS 2007 NFPA 13 and 2007 NFPA 24 Project: Listed items require sprinkler
More informationWest District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8
City of Ottawa Project No. CR006230 Page 1 of 8 PART 1 - GENERAL 1.1 Reference Standards.1 Conform to the following:.1 Provincial and municipal building and fire regulations as approved by Provincial Fire
More informationInspector: PROPERTY INFORMATION Photo Smoke Detector Notification Control Panel Stand Alone Smoke Detector Dialer SUMMARY ONLY
FIRE ALARM INSPECTION AND TESTING SUMMARY PAGE PER 2013 NFPA 72 Inspector: Jim Smith Test Date: 5/22/2014 PROPERTY INFORMATION Name of Property: Windsor Tower Owner of Property: Jim Gibbs Properties Address:
More informationEL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD INSTALLATION OF COMMERCIAL FIRE SPRINKLER SYSTEMS STANDARD #C-001 EFFECTIVE 03-25-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain
More informationEL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD
EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD Installation of Residential Fire Sprinkler Systems STANDARD #C-002 EFFECTIVE 03-19-2009 PURPOSE: To ensure that sprinkler plans submitted for review contain
More informationFire Sprinkler Submittal Requirements and Acceptance Testing
Lubbock Fire Marshal s Office 1601 Mac Davis Lane Lubbock, Texas 79401 806-775-2646 Fax 806-775-3508 fireprevention@mylubbock.us Fire Sprinkler Submittal Requirements and Acceptance Testing To all Registered
More informationSECTION SPRINKLER SYSTEMS
SECTION 15325 SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Wet-pipe sprinkler systems. B. Preaction sprinkler systems. C. System design, installation, and certification. D. Fire department
More informationSECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE
SECTION 21 1313 WET-PIPE SPRINKLER SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. Wet-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.02 RELATED
More informationInternational Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures
International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures Please note this is not an all-inclusive list. The type and complexity of your project
More informationSheetz Inc. Fire Protection Service Guidelines
Sheetz Inc. Fire Protection Service Guidelines Overview The following are guidelines for Sheetz Fire Protection Services for the 2016/2018 contract year. Each key area is listed below with the appropriate
More informationCubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM
SECTION 21 0000 AUTOMATIC FIRE SPRINKLER SYSTEM PART 1 GENERAL 1.1 QUALITY ASSURANCE A. Codes and Standards: 1. FBC (Florida Building Code 2015) 2. FBC (Florida Fire Code 2015) 3. NFPA #13R (Standard for
More informationSECTION WET-PIPE SPRINKLER SYSTEMS
SECTION 21 13 13 PART 1 - GENERAL 1.1 SCOPE OF WORK A. Design, installation and testing shall be in accordance with NFPA 13 except for specified exceptions. B. The design and installation of a hydraulically
More informationFalse Sense of Security???
IS YOUR SPRINKLER SYSTEM GIVING YOU A FALSE SENSE OF SECURITY? Best Practices in Fire Safety An ASSE Virtual Symposium March 1 & 2, 2011 Walter S. Beattie CSP, CFPS, CSHM False Sense of Security??? Fire
More informationBurnsville Fire Department 100 Civic Center Pky, Burnsville, MN Fire Marshal: FAX:
Burnsville Fire Department 100 Civic Center Pky, Burnsville, MN 55337 Fire Marshal: 952-895-4579 FAX: 952-895-4512 2018 FIRE SUPPRESSION PERMIT APPLICATION PERMIT Wet System Dry System Cooking Hood Clean
More informationPlan Review Check List Fire Alarm System
Plan Review Check List Fire Alarm System EXCELSIOR FIRE DISTRICT 241OO SMITHTOWN ROAD SHOREWOOD, MN 55331 Alarm system must be installed according to NFPA 72, 2010 Edition, National Fire Alarm and Signaling
More informationESCONDIDO FIRE DEPT TRAINING MANUAL Section Engine Module Page 1 of 8 Annual Sprinkler System Inspection Revised
Engine Module Page 1 of 8 ANNUAL INSPECTOR S TEST Note: In 2014 the Escondido Fire Department discontinued performing an Inspector s Test on sprinkler systems electing to inspect the system as outlined
More informationFire Alarm Testing and Inspection Report
Fire Alarm Testing and Inspection Report Property Name: Property Address: Property Manager: Contact: Phone Number: Central Station: Phone Number: PELICAN ISLE II 35 DOCKSIDE RD. NAPLES, FLORIDA 3110 BILL
More informationRevised March 2015 Fire Alarm Systems Verification. Schedule I(A) Services. *Manditory Site visit required*
1.0 Description of Services Required: Revised March 2015 Fire Alarm Systems Verification Schedule I(A) Services *Manditory Site visit required* Perform the annual fire alarm system and sprinkler system
More informationDesign & Construction Standards, Revised January
PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of The University of Texas at Austin for the design and construction of standpipe systems to include combination standpipe
More informationDISTRICT OF SECHELT. Inspection and Testing of Fire Protection Equipment Bylaw No. 397, 2002
DISTRICT OF SECHELT Inspection and Testing of Fire Protection Equipment Bylaw No. 397, 2002 WHEREAS Section 653 of the Local Government Act authorizes Council by bylaw to regulate businesses, business
More informationD. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:
PART 1 GENERAL 1.01 Scope of Standard A. This standard provides general requirements of Sam Houston State University for the design and construction of standpipe systems to include combination standpipe
More informationUNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1
GENERAL: 1. All fire protection systems shall be installed in accordance with the International Fire Code and applicable NFPA standards. This guideline provides additional requirements for the design and
More informationEXHIBIT D ATTACHMENT G - UNIT PRICING DMS-14/15-039B - SIMPLEXGRINNELL, LP FIRE SPRINKLER SYSTEM INSPECTIONS YEARS 1-5
UNIT PRICING IS A "NOT TO EXCEED" PRICE EXHIBIT D ATTACHMENT G - UNIT PRICING DMS-14/15-039B - SIMPLEXGRINNELL, LP FIRE SPRINKLER SYSTEM INSPECTIONS YEARS 1-5 Unit Pricing to perform all required Test
More informationCITY OF PASADENA FIRE DEPARTMENT
Page 1 of 8 CITY OF PASADENA FIRE DEPARTMENT INSTALLATION OF COMMERCIAL SPRINKLERS (Revised 12/10/2014) SCOPE: This standard applies to the design and installation of automatic fire sprinkler systems in
More informationAUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)
AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations) This standard applies to the design and installation of automatic fire sprinkler systems in conjunction with
More informationGas Station & C Store SECTION CWM Job No
SECTION 21 1300 - PART 1 - GENERAL 1.1 WORK INCLUDED A. Provide labor, materials, equipment and services to perform operations required for the complete installation and related Work as required in Contract
More informationFacilities Management
Facilities Management Policy Number: 700.4 Title: Fire Protection & Life Safety Inspection Policy Implementation Date: August 1 st, 2008 Last Revised: September 14 th, 2017 Last Audited: August, 2017 Introduction
More informationWALL ESCUTCHEON PIPE SEAL WITH APPROVED FIRE CAULKING (SEE SPECIFICATIONS) NOTE: 12" 12" 24"
SOUTH TEJON ST., SUITE 00 COLORADO SPRINGS, CO. 00 TELE.: FAX: WALL ESCUTCHEON PACK ANNULAR SPACE WITH MINERAL WOOL GENERAL NOTES. THIS PROJECT INCLUDES THE DESIGN AND PROVISION OF A NEW WET SPRINKLER
More informationSECTION DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE
SECTION 21 1316 DRY PIPE SPRINKLER SYSTEMS MODEL G SERIES DRY VALVE PART 1 GENERAL 1.01 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department
More informationSECTION WET-PIPE SPRINKLER SYSTEMS
SECTION 21 13 13 WET-PIPE SPRINKLER SYSTEMS PART 1 - GENERAL 1.1 SCOPE OF WORK A. Design, installation and testing shall be in accordance with NFPA 13 except for specified exceptions. B. The demolition
More informationSECTION DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE
SECTION 21 1316 DRY PIPE SPRINKLER SYSTEMS MODEL F SERIES DRY VALVE PART 1 GENERAL 1.01 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department
More informationPrefunctional Checklist
This should be completed as part of startup and initial checkout of the equipment in preparation for Functional Performance testing. PC: 28 31 76 ITEM: Fire Alarm/Mass Notification System ID: (Use one
More informationFIRE INSPECTION CHECKLIST
Applicable Base Codes FIRE INSPECTION CHECKLIST Florida Fire Prevention Code, 5th Edition NFPA 1, Uniform Fire Code, Florida 2012 Edition NFPA 101, Life Safety Code, Florida 2012 Edition NFPA 13, 2010
More informationChecklist For Life Safety
INSPECTION CHECKLIST Date of Inspection: Location/Address: Weather Condition: Inspector: AFTER COMPLETING YOUR INSPECTION, TRANSFER YOUR CONCERNS/OBSERVATIONS TO THIS AREA Facility: Name: Staff Contact:
More informationCLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau
CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 Permit Type: 105.7.13 Control Number: A.0 Effective Date: 11/15/11 TITLE:
More informationA. This section includes design and performance information for fire protection and suppression systems.
SECTION 21 00 10: FIRE PROTECTION SYSTEM DESIGN 1. SUMMARY A. This section includes design and performance information for fire protection and suppression systems. 2. GENERAL A. All fire protection materials
More information1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.
FIRE PROTECTION GENERAL INFORMATION 1.1 Refer to Section 230000 for General Mechanical Requirements. 1.2 Refer to Section 230529 for Hangers and Supports. 1.3 Refer to Section 230553 for Pipe and Equipment
More informationDivision 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21
Division 21: FIRE SUPRESSION 21 1313 WET-PIPE SPRINKLER PROTECTION SYSTEM Table of Contents 1 Division 21 SECTION 21 1313 WET-PIPE SPRINKLER PROTECTION SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS A.
More informationFIRE SAFETY SYSTEMS MAINTENANCE INFORMATION
FIRE SAFETY SYSTEMS MAINTENANCE INFORMATION To be kept in school administration office Crown Copyright, Province of Nova Scotia 2004 Prepared by Nova Scotia Department of Education No part of this document
More informationUniversity of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL
SECTION 21 13 16 DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section
More informationB. Section Identification for Fire Suppression Piping and Equipment.
SECTION 211300 - FIRE SUPPRESSION SPRINKLERS PART 1 GENERAL 1.1 SECTION INCLUDES A. Dry-pipe sprinkler system. B. System design, installation, and certification. C. Fire department connections. 1.2 RELATED
More informationOther EC and LS documents may be requested by surveyors, as needed, throughout the survey.
Documentation required by the Hospital Accreditation program Life Safety (LS) and selected Environment of Care (EC) standards is presented in the following pages. These documents will be reviewed by the
More informationFIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.
15500 - FIRE PROTECTION PART I DESIGN GUIDELINES A. General 1. Vertical fire pumps shall not be used at the University. 2. coupling piping shall be permitted for sprinkler and standpipe systems only. B.
More informationEstablished /10/2015. Doran Pruisner Dan Wood
Established 1911 Doran Pruisner Dan Wood The International Fire Code, 2009 Edition shall apply to all occupancies except for those that are explicitly excluded by these provisions. 1 Buildings built between
More information2016 CDM Smith All Rights Reserved July 2016 SECTION FIRE PROTECTION - SPRINKLER AND STANDPIPE SYSTEMS
PART 1 GENERAL 1.01 SCOPE OF WORK SECTION 21 13 13 FIRE PROTECTION - SPRINKLER AND STANDPIPE SYSTEMS A. Furnish all labor, materials, equipment services and incidentals required to design and install properly
More information1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:
SECTION 21 10 00 - WATER-BASED FIRE-SUPPRESSION PART I - GENERAL 1.1 SUMMARY A. Inclusion of sprinkler and standpipe systems shall be as determined by NFPA National Fire Code pamphlet 101 and program statement.
More informationUNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY
Revision No.: 3 Page 1 of 6 I. PURPOSE This policy establishes the steps required for performing the monthly fixed systems inspections and the semi-annual systems testing. Fixed systems include; wet chemical
More informationYou are required to READ ALL PAGES. of this application
Fire/Smoke/Heat/CO Application Checklist You are required to READ ALL PAGES of this application NEW ROCHELLE FIRE DEPARTMENT 90 Beaufort Pl, New Rochelle, NY 10801 - (914) 654-2213 APPLICATION FOR FIRE/SMOKE/HEAT/CO
More informationDIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES
DIVISION 21 FIRE SUPPRESSION PART 1 GENERAL 1.01 DESCRIPTION A. Provide UL listed, FM approved listed fire protection specialties or accessories as required by either the equipment manufacturer or the
More informationBuilding Life Safety Systems Testing
Insert Logo Here Service Company Information (Address, Telephone, & Contact Information Building Life Safety Systems Testing Date of Service: Last Service Date: Work Order Number: Contact Person: Phone:
More information1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors)
1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors) 1. What is the minimum diameter for a non-hydraulically calculated Class III fire standpipe that is part of a combined
More informationTECHNICAL DATA EASYPAC COMMERCIAL RISER MANIFOLD ASSEMBLIES 1-1/4-8 (DN32 - DN200)
Page 1 of 6 1. DESCRIPTION Viking EasyPac Commercial Riser Manifold Assemblies are available in sizes 1-1/4, 1-1/2, 2, 2-1/2, 3, 4, 6 and 8 for commercial systems. They are available with an AGF TESTanDRAIN
More informationFire Permit Application
Fire Permit Application FOR STAFF USE ONLY Case Permit Number: Plan Number: Related permits: Project #: Responsibility for information Although designated Department staff members will help you with general
More informationSECTION FIRE-SUPPRESSION STANDPIPES
PART 1 - GENERAL 1.1 DESCRIPTION Fire-suppression wet and manual dry standpipes. 1.2 SCOPE OF WORK SECTION 21 12 00 A. Design, installation and testing shall be in accordance with NFPA 14 except for specified
More informationDIVISION 21 - FIRE SUPPRESSION
DIVISION 21 - FIRE SUPPRESSION DESIGN CRITERIA It is the policy of UC Davis to install fire sprinkler systems in all new construction/facilities. If the building is classified as a pole barn, shed, carport,
More informationFire Alarm and Life Safety System Inspection Certificate
Fire Alarm and Life Safety System Inspection Certificate For Sample Inspection Report 123 Main Street Anywhere, USA 30303 Tested to NFPA 72 Standards This Inspection was performed in accordance with applicable
More informationDESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES
SECTION 21 13 00 - FIRE SUPRESSION SPRINKLER SYSTEMS SCOPE OF WORK This standard provides general guidance concerning the specific preferences of The University of South Alabama for automatic fire sprinkler
More informationPLAN REVIEW CHECKLIST
PLAN REVIEW CHECKLIST Date Documents Submitted: Log No.: File No.: Property Information Building Name: Building Address: Owner s Name: Owner s Address: Owner s Phone: Fax: E-mail: System Designer/Contractor
More informationCITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST
CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST DATE: PROJECT NO.: EXPIRATION DATE: STATUS: INFORMATION PROJECT ADDRESS:
More informationTECHNICAL DATA. 32a. September 18, /4-8 (DN32 - DN200)
September 18, 2009 32a 1. DESCRIPTION Viking EasyPac Floor Control Riser Manifold Assemblies are available in sizes 1-1/4, 1-1/2, 2, 2-1/2, 3, 4, 6 and 8 for commercial use, in high rise buildings requiring
More informationADDENDUM NO. 3 March 19, 2018
ADDENDUM NO. 3 March 19, 2018 PROJECT: MT. VIEW ELEMENTARY CASSIA SCHOOL DISTRICT NO 151 BURLEY, IDAHO The following addenda apply to the Project Manual and / or Drawings for this project and shall be
More information*** Inspection *** Please identify yourself as a Cintas representative when arriving onsite.
Tech Clock-In/Out IVR: 1-877-349-2906 Job #: Tech ID #: 2902 FP Service Instructions Job #: *** Inspection *** You must clock in and out of this job through Cintas's IVR phone system! Call 1-877-349-2906
More information