TEST REPORT. Junction Box (Dimension 123x78mm) MakelModel No. Raychem /- Serial No. l?qdcg/1641 Quantity/ No. of samples

Size: px
Start display at page:

Download "TEST REPORT. Junction Box (Dimension 123x78mm) MakelModel No. Raychem /- Serial No. l?qdcg/1641 Quantity/ No. of samples"

Transcription

1

2 B 177/178, GIDC Electronics Estate, Sec-25, Gandhinagar (Under STQC Programme, DIT, Ministry ofcomm. & Infonnation Technology, Govt. ofindia) REPORT NO.: EQP/G0204/0304/2012 Page 1 00 TEST REPORT Service Request Form No. SRFDate: Date of Issue: G0204/ /03/ /03/2012 Name & Address ofthe Customer Mis. Raychem RPG Limited, Ceta Mahal Annexe, 463, Dr.Annie Besant Road, Worli, Mumbai. DESCRIPTION/ IDENTIFICATION OF THE ITEM Nomenclature Junction Box (Dimension 123x78mm) MakelModel No. Raychem /- Serial No. l?qdcg/1641 Quantity/ No. of samples 01 Date ofreceipt ofitem 16/03/2012. Date ofcompletion oftest 19/03/2012 Condition ofequipmentlmaterial on receipt. Good Location where test is performed LAB, EQDC- Gandhinagar Test Specification With reference to IS/IEC 60529: 2001 Clause No. 13.4, , , 14.3 Test facilities used: Nomenclature Make/Model Serial Number Calibration Due Date 1J Dust Chamber C.K. Enterprise/- EQDCG/ /12/2012 2] Water Tank EQDC/- EQDCG/WT-01 - Prepared by:.~j---- Form No.: T/2/GEN.,Issue No: 03, Rev-OS, Dated

3 .'''.'''~ - -, ELECTRONICS AND QUALITY DEVELOPMENT CENTRE B 177/178, GillC Electronics Estate, Sec-25, Gandhinagar (Under STQC Progranune, DlT, Ministry ofcomm. & lnfonnation Technology, Govt. oflndia) REPORT NO.: EQP/G0204/0304/2012 Page 2 of3 TEST RESULT Sr. Test No. Parameters 1 IP6X: (Dust-tight Test) Test Method /Requirement Observations Remarks Ensure the degree of protection provided by the enclosure against penetration of dust by using following test. The EDT is supported in its normal operating position inside the test chamber in which talcum powder is maintained in suspension. The duration ofthe test is eight hours. The protection is satisfactory if no deposit of dust is observable inside the enclosure at the end of the test. After the test no dust found inside the EDT. 2 IPX8: (Temporary Immersion in water Test) Ensure the Degree of Protection provided by the enclosure against water by using following test: Method The EDT is completely immersed in the water. The surface ofthe wilier shall be at least 150 mm above the highest poin(ofthe item. The lowest portion of the item shall be at least 1 meter below the surface ofthe water. The duration ofthe test is Ihr. The water temperature shall not differ from that of the item by more than 5 C. After completion of test the item shall be removed from the water and visually examined for the ingress of water inside the item. Requirement Ingress ofwater shall not be sufficient to interfere the satisfactory operation ofthe equipment. No water found inside. the EDT. I Prepared by: &~ Form No.: T/2/GEN.,Issue No: 03, Rev-OS, Dated

4 B 177/178, GIDC Electronics Estate, Sec-25, Gandhinagar (Under STQC Programme, DlT, Ministry ofcomrn. & Infonnation Technology, Govt. ofindia) REPORT NO.: EQPJG0204J0304J2012 Page 3 of3 Remarks: 1) EUT: - Equipment under Test. 2) Holograms having Sr. No to affixed on each page oftest report. NOTE: 1. This report refers only to particular item(s)l equipment(s) submitted for testing. 2. This report shall not be reproduced except in full without the written approval from Director, EQDC (Gandhinagar). 3. The test results reported are valid at the time of and under the stated condition of measurement. 4. Only the test asked for by the party have been carried out. 5. Any anomalies/ discrepancies in this report should be brought to 0 from the date of issue of this re ort. Prepared by: ~ Officer In-CHarge Customer Service Celt

5 B 177/178, GillC Electronics Estate, Sec-25, Gandhinagar (Under STQC Progranune, DIT, Ministry ofcomm. & Infonnation Technology, Govt. ofindia) REPORT NO.: EQP/G0214/0314/2012 Page 1 of3 TEST REPORT Service Request Form No. SRFDate: Date ofissue : G0214/ / /2012 Name & Address ofthe Customer Mis. Raychem RPG Limited, Ceta Mahal Annexe, 463, Dr.Annie Besant Road, Worli, Mumbai. DESCRIPTIONI IDENTIFICATION OF THE ITEM Nomenclature Junction Box (Dimension 123x78mm) MakelModel No. Raychem 1--. Serial No. EQDCGI1642 Quantity/ No. of samples 01 Date ofreceipt ofitem Date ofcompletion oftest ~ 23/03/2012 Condition ofequipmentlmaterial on receipt Good. Location where test is performed LAB, EQDC- Gandhinagar Test Specification With reference to IS/IEC 60529: 2001 Clause No. 13.4, , , 14.3 Test facilities used: Nomenclature MakelModel Serial Number Calibration Due Date 1] Dust Chamber C.K. Enterprise/- EQDCG/ /2012 2] Water Tank EQDCI- EQDCGIWT Prepared by: ~J--- Form No.: T/2/GEN.,Issue No: 03, Rev-OS, Dated

6 B 177/178, GIDC Electronics Estate, Sec-25, Gandhinagar (Under STQC Programme, DIT, Ministry ofcomrn. & Infonnation Technology, Govt. ofindia) REPORT NO.: EQP/G0214/0314/2012 Page 2 of3 Sr. No. Test Parameters IP6X: (Dust-tight Test) (Dimension 123x78mm) 2 IP X8: (Temporary Immersion in water Test) (Dimension 123x78mm) TEST RESULT Test Method /Requirement Observations Remarks Ensure the degree of protection provided by the enclosure against penetration of dust by using following test. The EUT is supported in its nonnal operating position inside the test chamber in which talcum powder is maintained in suspension. The duration of the test is eight hours. The protection is satisfactory if no deposit of dust is observable inside the enclosure at the end of the test. Ensure the Degree of Protection provided by the enclosure against water by using following test: ~ Method water. The EUT is completely immersed in the The surface of the water shall be at least 150 mm above the highest point of the item. The lowest portion of the item shall be at least 1 meter below the surface of the water. The duration of the test is Ihr. The water temperature shall not differ from that ofthe item by more than 5 C.. After completion of test the item shall be r~moved from the water and visually examined for the ingress of water inside the item. Reguirement Ingress of water shall not be sufficient to interfere the satisfactory operation of the equipment. After the test no dust found inside the EUT. No water found inside the EUT. Prepared by: ~ Form No.: T/2/GEN.,Issue No: 03, Rev-OS, Dated

7 ~\\ yd ~~. g' ELECTRONICS AND QUALITY DEVELOPMENT CENTRE B 177/178, GlDC Electronics Estate, Sec-25, Gandhinagar (Under STQC Programme, DlT, Ministry ofcornm. & Information Technology, Govt. ofindia) REPORT NO.: EQP/G0214/0314/2012 Instrument Photographs E(!)<~C.... c,i Page 3 of3 " Remarks: 1) EUT: - Equipment under Test. 2)Holograms having Sr. No to affixed on each page of test report. PrepMedby: ~ NOTE: I. This report refers only to particular item(s)/'equipment(s) submitted for testing. 2. This report shall not be reproduced except in full without the written approval from Director, EQDC (Gandhinagar). 3. The test results reported are valid at the time ofand under the stated condition ofin: urement. 4. Only the test asked for by the party have been carried out. 5. Any anomalies! discrepancies in this report should be brought to our no. date ofissue ofthis re ort. Issued by : Name : N' ii S jl a Desi nation: n Char e C

TEST REPORT Report No.: HN80013/2011 Page: 1 of 7 Date: August 30, 2011

TEST REPORT Report No.: HN80013/2011 Page: 1 of 7 Date: August 30, 2011 Page: 1 of 7 Date: August 30, 2011 GLACIALTECH INC. 9FL, NO. 352, SEC. 2, JUNG SHAN RD., JUNG HE CITY, TAIPEI, TAIWAN The following merchandise was submitted and identified by the vendor as: Product Description:

More information

TEST REPORT Reliability Laboratory Report No.: HCD0203/2008

TEST REPORT Reliability Laboratory Report No.: HCD0203/2008 Reliability Laboratory Page: 1 of 5 Date: December 23, 2008 WINMATE COMMUNICATION INC. 9 F, NO. 111-6, SHING-DE RD., SAN-CHUNG CITY, TAIPEI, TAIWAN, R.O.C. The following merchandise was submitted and identified

More information

TEST REPORT IEC60529 Edition TD990426C02

TEST REPORT IEC60529 Edition TD990426C02 Page 2 of 7 Report Reference No...: Compiled by...: Approved by...: TEST REPORT See cover sheet See cover sheet Date of issue...: May 11, 2010 Testing Laboratory...: Address...: Applicant s name...: Address...:

More information

EN 60529:1991+A1:2000+A2:2013 Measurement and Test Report

EN 60529:1991+A1:2000+A2:2013 Measurement and Test Report EN 60529:1991+A1:2000+A2:2013 Measurement and Test Report For Fujian Juston Electronic Equipment Co.,Ltd No.115,117,119,Yuantai 3rd Road,Jiangnan Hi-tech Park,Licheng District, Quanzhou,Fujian,China 362000

More information

TEMPORARY IMMERSION AND DUST TEST REPORT

TEMPORARY IMMERSION AND DUST TEST REPORT Report No. :HS1007140060A Version:A TEMPORARY IMMERSION AND DUST TEST REPORT Company :Gold Apollo Co., Ltd Address :3F.-1, No.77, Sec. 1, Xintai 5th Rd., Xizhi City, Taipei County 221, Taiwan (R.O.C.)

More information

TEMPORARY IMMERSION AND DUST TEST REPORT

TEMPORARY IMMERSION AND DUST TEST REPORT Report No. :DH1510130042A Version:A TEMPORARY IMMERSION AND DUST TEST REPORT Company Address :GradConn Ltd. :No. 139 Wuhan Rd., Longtan Township, Taoyuan County, Taiwan Sample Name :Refer to see page 2

More information

PURPOSE. 03/08/18 REVISOR SGS/HR RD The purpose ofparts to is to protect public health by establishing

PURPOSE. 03/08/18 REVISOR SGS/HR RD The purpose ofparts to is to protect public health by establishing 1.1 Department of Health 1.2 Proposed Permanent Rules Relating to Radon Licensing u 4620. 7000 PURPOSE. 1.4 The purpose ofparts 4620.7000 to 4620.7950 is to protect public health by establishing 1.5 licensing

More information

Contact person Date Reference Page Henrik Andersson F (4) Electronics

Contact person Date Reference Page Henrik Andersson F (4) Electronics issued by an Accredited Testing Laboratory Contact person Henrik Andersson 2016-05-19 6F009034 1 (4) Electronics +46 10 516 55 74 henrik.andersson@sp.se Accred. No. 1002 Testing ISO/IEC 17025 ENOC SYSTEM

More information

Certificate of Approval

Certificate of Approval Certificate of Approval This is to certify that the Management System of: Raychem RPG Private Limited RPG House, 463, Dr. Annie Besant Road, Worli, Mumbai, 400030, India has been approved by LRQA to the

More information

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 PPE-R/00.017 Version 2 RECOMMENDATION FOR USE Number of pages: 5 Approval stage : Approved on : Origin : Horizontal Committee, C2D Ad hoc group

More information

SECTION Fluorescent Dissolved Oxygen Measuring System

SECTION Fluorescent Dissolved Oxygen Measuring System SECTION 40 75 43 Fluorescent Dissolved Oxygen Measuring System PART 1 General 1.01 SUMMARY A. Requirements for a high-performance, digital fluorescence sensor for measurement of dissolved oxygen in liquid.

More information

EU-Type Examination Certificate

EU-Type Examination Certificate EU-Type Examination Certificate Measuring Instrument Directive Certificate number: 0200-MID-02784 Issued by FORCE Certification A/S, Denmark EU-notified body number 0200 In accordance with the Directive

More information

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS Network(s): Summary: ENGINEERING COMMISSIONING PROCEDURE ECP 11-0009 OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS EPN, LPN, SPN This standard details the requirements for the splicing,

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/XXX Original: English Distribution: General TITLE: Integrated electronic maximum-minimum thermometer, with factory programmed alarms, for vaccine refrigerators

More information

ENVIRONMENTAL TEST REPORT

ENVIRONMENTAL TEST REPORT ENVIRONMENTAL TEST REPORT PO #: 0000025127 Quote #: 090206BH Test #: IDAH-090052 REV000 Idaho Technology February 23, 2009 PROPRIETARY Page 1 of 13 Idaho Technology 11 day Temp/Humidity Test APPROVALS

More information

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming) 02Oct08 Rev A 1. SCOPE 1.1. Content This specification, based on IEC 61753-1 Edition 1.0 tests for Category E (Extreme Environment),

More information

DUST TEST REPORT. :Gold Apollo Co., Ltd. Company Model Name :A27. Date of Received :APR. 19, 2006 Date of Tested :APR. 19, 2006

DUST TEST REPORT. :Gold Apollo Co., Ltd. Company Model Name :A27. Date of Received :APR. 19, 2006 Date of Tested :APR. 19, 2006 Report No.:RA-S9504-0992 Reliability Engineering Division Page: 1 of 5 1F, No.22, Pu-ding Rd., Hsin - chu City, Taiwan, R.O.C. http://www.isti.com.tw Company Model Name :A27 DUST TEST REPORT :Gold Apollo

More information

Lawnmowers (pedestrian controlled, battery powered)

Lawnmowers (pedestrian controlled, battery powered) Compliance Guide Rev.01, Edition 04/2018 Lawnmowers (pedestrian controlled, battery powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org +32 2 206

More information

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - TF N 687rev1 2015-06-02 CONSTRUCTION SECTOR STANDARDIZATION GUIDANCE DOCUMENT Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - 1 I - Drafting

More information

Environment Test Report

Environment Test Report Environment Test Report Product Name: Product Model: Product Type: Power System TP48200A TP48200A-H15A3 TP48200A-H15A5 TP48200A-D15A1 Report Number: SYBH(H) 346052012 Reliability Laboratory of Huawei Technologies

More information

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY Industry standards for electrical enclosures exist to promote safety, encourage design efficiency and define minimum levels of product performance.

More information

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor SECTION 40 75 53 Process and Immersion Turbidity and Total Suspended Solids Sensor PART 1 General 1.01 SUMMARY A. Requirements for a digital sensor for process turbidity or Total Suspended Solids (TSS)

More information

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES, FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. ON FLOW MONITOR, GPE3000 SERIES, REPORT NO. TRA-015825-33-00A ExTR Reference No. TRA-015825-33-00A

More information

Conventional Feeder Pillar Box

Conventional Feeder Pillar Box Vertical Service Fuse Unit Feeder Pillar Box ACB/MCCB/DG Set/ APFC Panels Remote Feeder Monitoring System Conventional Feeder Pillar Box Fully Insulated s Wall Mounted/Retrofit Underground Anti-theft Distribution

More information

Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986

Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986 Ministry of Environment & Forests, New Delhi Central Pollution Control Board, Delhi Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986 Surveillance

More information

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618 Description Duration Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618 Animals:Goats:Herd,Bleat.Calls,Intensity.Increase,Warbling,Baby.Baa,Movements.Rubbing,Barn,Occasional.Dog.Barks,Medium.Close,Interior,BG.Crows.Squawks

More information

C e r t i f i c a t e

C e r t i f i c a t e C e r t i f i c a t e of EC Type-examination (Module B) Certificate Nº: 09212007/AA/01 Product Category: A.1/5.13 With respect to Marine Equipment Directive 96/98/EC and the amending Directive 2008/67/EC,

More information

Shipboard incinerators with capacities up to 4000 kw

Shipboard incinerators with capacities up to 4000 kw STANDARD FOR CERTIFICATION No. 2.9 Approval Programmes Type Approval Programmes for Marine Equipment Directive (MED) No. 431.90 - MED A.1/2.7 Shipboard incinerators with capacities up to 4000 kw JANUARY

More information

Survey of electrical equipment installed in hazardous areas on tankers

Survey of electrical equipment installed in hazardous areas on tankers (June 2015) Survey of electrical equipment installed in hazardous areas on tankers 1. Application The recommendations in this document apply for survey of electrical installation in hazardous areas on

More information

CERTIFICATE of QUALITY TEST

CERTIFICATE of QUALITY TEST Testing laboratory for climatic, mechanical and corrosive environmental stress CERTIFICATE of QUALITY TEST Test report - No. 10142 / 13 Client ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210

More information

CERTIFICATION OF EXPLOSIVES UNDER G.B. STATUTORY INSTRUMENT No. 2714

CERTIFICATION OF EXPLOSIVES UNDER G.B. STATUTORY INSTRUMENT No. 2714 < SK i 91 < United K,n'h""" hs!.uk CERTIFICATION OF EXPLOSIVES UNDER G.B. STATUTORY INSTRUMENT No. 2714 APPROVAL TO AFFIX THE CE MARK AND THE IDENTIFICATION NUMBER OF THE EXPLOSIVES NOTIFIED BODY (0519)

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com CLASSIFICATION CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE

More information

Issued to: Videl S.r.l. Località Ponti di Pievescola Casole d Elsa (SI)

Issued to: Videl S.r.l. Località Ponti di Pievescola Casole d Elsa (SI) TEST REPORT N. TRP_297_12 CETACE Laboratory in collaboration with Electronic and Telecommunication Department of the University of Florence Title: IP23 test Reports consists of no. 16 pages Result: Pass

More information

NATIONAL TECHNICAL SYSTEMS

NATIONAL TECHNICAL SYSTEMS Test Report Number PR034844.CRW Testing of Test Samples PREPARED FOR: PREPARED BY: Crownduit 214 William Street Red Bank, NJ 07701 National Technical Systems 36 Gilbert Street South Tinton Falls, NJ 07701

More information

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer TEST REPORT IEC 61000-4-2-2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test Report Reference No....: SQE13090002 R/C: 60520

More information

CERTIFICATION OF EXPLOSIVES UNDER G.B. STATUTORY INSTRUMENT No. 2714

CERTIFICATION OF EXPLOSIVES UNDER G.B. STATUTORY INSTRUMENT No. 2714 ~~ HSE Health & Safety Executive GB Explosives Notified Body, Health & Safety Laboratory, Harpur Hill, Buxton, Derbyshi re, SK 17 9JN, United Kingdom Tel: +44 (0)1298 218150 Fax: +44 (0)1298 218180 Email:

More information

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax: STANDARD FOR CERTIFICATION No. 2.9 RADAR REFLECTOR JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent Foundation with

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/XXX Original: English Distribution: General TITLE: Wall-mounted pen recording thermometer Product verification protocol: E06/TR04VP Applies to specification ref(s):

More information

Sound Pressure Level Test Report Report No. : PH2_09_ Date : 2009/6/30

Sound Pressure Level Test Report Report No. : PH2_09_ Date : 2009/6/30 聲學測試實驗室 PAL Acoustics Technology Ltd. 4F, No, 388, Sec.1, Nei Hu Rd., Taipei, Taiwan. 114 Tel:886-2-2627-2515 Fax:886-2-2627-2295 www.pal-acoustics.com Sound Pressure Level Test Report Report No. : PH2_09_0227-1

More information

Not to be reproduced without the permission of Last date for receipt of BIS or used as a STANDARD comments is: 15 July 2012

Not to be reproduced without the permission of Last date for receipt of BIS or used as a STANDARD comments is: 15 July 2012 For Comments Only Draft Indian Standard Graphic technology -- Safety systems -- Part 1: General requirements ICS 37.100.10 Not to be reproduced without the permission of Last date for receipt of BIS or

More information

On Electromagnetic Compatibility

On Electromagnetic Compatibility TECHNICAL REGULATION On Electromagnetic Compatibility Approved by Resolution of Cabinet of Ministers of Ukraine No. 785 dd. 2009.07.29 ELMAS LTD Index Index...2 General Provisions...3 Essential Requirements...5

More information

Eligibility Criteria for Participation [Qualification Requirement (QR)]

Eligibility Criteria for Participation [Qualification Requirement (QR)] Eligibility Criteria for Participation [Qualification Requirement (QR)] 1. Only Manufacturers are eligible to Quote: a) Original manufacturers of High Voltage Detector in India will be eligible in the

More information

NF MARK RIGID NON-PLASTICISED PVC PIPES AND FITTINGS

NF MARK RIGID NON-PLASTICISED PVC PIPES AND FITTINGS Mandated by CENTRE SCIENTIFIQUE ET TECHNIQUE DU BATIMENT Certifying Body 84 avenue Jean Jaurès Champs sur Marne F 77442 MARNE-LA-VALLEE Cedex 2 11 rue Francis de Pressensé F 93571 LA PLAINE SAINT DENIS

More information

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures ON THE BUTTON A reference guide to environmental ratings used for push button enclosures A REFERENCE GUIDE TO KEY TOPICS IN PUSH BUTTON SELECTION AND SAFETY CONTENTS I. INTRODUCTION...............................

More information

SIMPLIFIED VOYAGE DATA RECORDER (S-VDR)

SIMPLIFIED VOYAGE DATA RECORDER (S-VDR) STANDARD FOR CERTIFICATION No. 2.9 SIMPLIFIED VOYAGE DATA RECORDER (S-VDR) APRIL 2009 Veritasveien 1, NO-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD (DNV) is an autonomous and

More information

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY ("Official Gazette of RS, issue No. 13/2010) I INTRODUCTION Scope Article 1 This Rulebook stipulates the essential requirements that shall be met with regard to

More information

SECTION Free/Available Chlorine Analysis System

SECTION Free/Available Chlorine Analysis System SECTION 40 75 21 Free/Available Chlorine Analysis System PART 1 General 1.01 SUMMARY A. Requirements for a digital sensor system for free chlorine measurement for disinfection purposes in drinking water,

More information

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X Installation Instructions P/N MMI-20010174, Rev. A June 2007 ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X For ATEX-approved sensor installations

More information

CERTIFICATION OF EXPLOSIVES UNDER G.B. STATUTORY INSTRUMENT 2016 No 315

CERTIFICATION OF EXPLOSIVES UNDER G.B. STATUTORY INSTRUMENT 2016 No 315 Health and Safety Executive, (GB Explosives Notified Body), Health & Safety Laboratory, Harpur Hill, Buxton, Derbyshire, SK 17 9JN, United Kingdom Tel: +44 (0)203 028 22 16 Email: enb@hsl. gsi.gov.uk www.hsl.

More information

ENGROSSED SUBSTITUTE HOUSE BILL State of Washington 60th Legislature 2007 Regular Session

ENGROSSED SUBSTITUTE HOUSE BILL State of Washington 60th Legislature 2007 Regular Session ENGROSSED SUBSTITUTE HOUSE BILL 1968 State of Washington 60th Legislature 2007 Regular Session By House Committee on Commerce & Labor (originally sponsored by Representatives Simpson, Conway and Ormsby)

More information

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3. Rev. 1 03/05/2015 ANNEX A to the Yokogawa Corporation of America Quality Assurance Manual For Additional Requirements selectively applied to ATEX and IECEx certified products CONTENTS 1. Scope 2. Purpose

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61241-1-2 Second edition 1999-06 Electrical apparatus for use in the presence of combustible dust Part 1-2: Electrical apparatus protected by enclosures and surface temperature

More information

GASTEC QA. Approval Requirements 31-2

GASTEC QA. Approval Requirements 31-2 KE 31-2 March 2012 GASTEC QA Approval Requirements 31-2 for the GASTEC QA product certificate for Sealing materials for metallic threaded joints in contact with 2nd and 3rd family gases and hot water Part

More information

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER INSTRUCTIONS FOR SAFE OPERATIONS LM000 EXPLOSION PROOF LASER DISTANCE METER www.cord-ex.com CONTENTS READ THIS FIRST Read This First Liability Trademark Information Product Information Special Conditions

More information

WIO200 Water in oil sensor

WIO200 Water in oil sensor WIO200 Water in oil sensor User manual Rev. 1.15 Dato: 2011-11-03 Page 1 of 24 TABLE OF CONTENTS Table of contents... 2 Introduction... 3 Safety Advice... 4 Function... 6 Normal operation... 7 Failure

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Product types SR853.8.x.x, Rev. 1 SR853 manual page2 The symbols WARNING, CAUTION, NOTE This symbol warns of a serious hazard. Failure to observe this warning may result in death

More information

GASTEC QA. Approval Requirements 31-1

GASTEC QA. Approval Requirements 31-1 KE 31-1 March 2012 GASTEC QA Approval Requirements 31-1 for the GASTEC QA product certificate for Sealing materials for metallic threaded joints in contact with 2nd and 3rd family gases and hot water Part

More information

Test Report to AS/NZS :2015. Report No. T160402_S

Test Report to AS/NZS :2015. Report No. T160402_S Page 1 of 6 EMC Technologies Pty Ltd ABN 82 057 105 549 Unit 3/87 Station Road Seven Hills NSW 2147 Australia Telephone +61 2 9624 2777 Facsimile +61 2 9838 4050 Email sales@emctech.com.au Test Report

More information

IQ/OQ Protocol Installation Qualification/ Operation Qualification SteamScrubber & FlaskScrubber Laboratory Glassware Washers

IQ/OQ Protocol Installation Qualification/ Operation Qualification SteamScrubber & FlaskScrubber Laboratory Glassware Washers IQ/OQ Protocol Installation Qualification/ Operation Qualification SteamScrubber & FlaskScrubber Laboratory Glassware Washers Labconco o: 1058700 Rev. B Purpose and Scope IQ and OQ This Qualification

More information

Test Report. Appliance EMF Testing

Test Report. Appliance EMF Testing Project: 11014506A Date: November 6, 2015 Model: 120V_WWF13NW Test Report On Appliance EMF Testing Copyright 2005 UL LLC UL LLC authorizes the above-named company to reproduce this Report provided it is

More information

Quality Assurance Plan for Conducting Radon Measurements

Quality Assurance Plan for Conducting Radon Measurements Quality Assurance Plan for Conducting Radon Measurements 921 Pheasant Run Lindsborg, Kansas 67456 (785) 510-0000 info@clarityinspect.com getyourinspection.com page 1 of 18 Table of Contents A.1 Approval

More information

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements Test Report issued under the responsibility of: TEST REPORT IEC 60825-1 Safety of laser products - Part 1: Equipment classification and requirements Report Number.... : 102254161MPK-001L Date of issue...

More information

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012 KE 191 - A1 March 2012 GASTEC QA Evaluation Guideline KE 191 Amendment A1 Excess flow valves Foreword and introduction These GASTEC QA Approval requirements amendment have been accepted by the Board of

More information

2. Safety instructions

2. Safety instructions User Guide Rev. 1.0 Contents 1.Introduction...3 2.Safety instructions...3 3.Product code...3 4.Memory size...4 5.Features...4 6.Specifications...4 7.Picture...4 8.Size & Dimensions...4 9.Operation...5

More information

Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch

Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch STANDARD FOR CERTIFICATION No. 2.9 TYPE APPROVAL PROGRAMME NO. 844.40 - MED A1/4.20-4.21-4.22-4.9 Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch FEBRUARY 2012

More information

CNBOP-PIB Standard Fire Protection

CNBOP-PIB Standard Fire Protection Centrum Naukowo Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego Państwowy Instytut Badawczy CNBOP-PIB-BA-01E:2014 Revision 1, February 2014 CNBOP-PIB Standard Fire Protection Laboratory Tests

More information

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002 Efectis Nederland BV Efectis Nederland report 2008-Efectis-R0431[Rev.1](E) Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

More information

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax: STANDARD FOR CERTIFICATION No. 2.9 MARINE GYRO COMPASS JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent Foundation

More information

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION INTERNATIONAL ELECTROTECHNICAL COMMISSION GUIDE 111 Second edition 2004-07 Electrical high-voltage equipment in high-voltage substations Common recommendations for product standards IEC 2004 Copyright

More information

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000 brochure On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000 Advanced Sensors Ltd Oil in Water Analyser System known as the OIW-EX100 or OIW-EX 1000. The system is designed to monitor

More information

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date: LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ALPHA TRACK Method Number: ELAP method number 7035 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: Page 1 of 6 RADON IN AIR

More information

MEASUREMENT AND TEST REPORT

MEASUREMENT AND TEST REPORT MEASUREMENT AND TEST REPORT For United GULF GATE Co. Aladel Tower,F21,Fahad Al Salem St., State of KUWAIT Model: XT-60 IP-PBX This Report Concerns: Original Report Equipment Type: IP PBX Test Engineer:

More information

SOUND RECEPTION SYSTEM

SOUND RECEPTION SYSTEM STANDARD FOR CERTIFICATION No. 2.9 SOUND RECEPTION SYSTEM APRIL 2009 Veritasveien 1, NO-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD (DNV) is an autonomous and independent foundation

More information

Model : LPSA-40A Please read this manual carefully before using the instrument Labnics Equipment

Model : LPSA-40A Please read this manual carefully before using the instrument Labnics Equipment DRY & WET DISPERSION PARTICLE SIZE ANALYZER Instruction Manual Model : LPSA-40A Please read this manual carefully before using the instrument Labnics Equipment Table of Content CHAPTER CONTENT PAGE No.

More information

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification

More information

incubator, the best in its class

incubator, the best in its class 188 188 188 EuroClone incubator, the best in its class More than a new tool: an environment with unique and unmatched features for your cell cultures. ED AN UCED I DESIGNED AND PRODUCED IN ITALY 1 The

More information

Specification for testing to be conducted at periodic surveillance of products and systems

Specification for testing to be conducted at periodic surveillance of products and systems Specification for testing to be conducted at periodic surveillance of products and systems RD_082, Issue 03 This guide describes the specification for testing to be conducted at periodic surveillance of

More information

Cavitator Ultrasonic Cleaner Instruction Manual

Cavitator Ultrasonic Cleaner Instruction Manual Cavitator Ultrasonic Cleaner Instruction Manual Made in China 1333 South Claudina Street Anaheim, CA 92805 Toll Free: (800) 854 9305 Tel: (714) 533 2221 FAX: (714) 635 7539 Web site: www.mettlerelectronics.com

More information

Size and rating wise typical Third Party Inspection certificates for the models of Valves

Size and rating wise typical Third Party Inspection certificates for the models of Valves For Item code star ting w i th 15 & 1 6 Control Valves: Supply references for valves supplies, for last three years, as per format A,B,C available in Annexure XVI (duly notarized/certified by statutory

More information

E/ECE/324/Rev.1/Add.27/Amend.5 E/ECE/TRANS/505/Rev.1/Add.27/Amend.5

E/ECE/324/Rev.1/Add.27/Amend.5 E/ECE/TRANS/505/Rev.1/Add.27/Amend.5 7 February 2018 Agreement Concerning the Adoption of Harmonized Technical United Nations Regulations for Wheeled Vehicles, Equipment and Parts which can be Fitted and/or be Used on Wheeled Vehicles and

More information

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date: LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: ELECTRET by Voltametry Method Number: ELAP method number 7034 SOP Number: Revision Number: SOP Date: Personnel / Data Records observed: General LLD:

More information

EC TYPE EXAMINATION (Module B) CERTIFICATE MARINE EQUIPMENT DIRECTIVE Certificate No.: 0832-MED-1019

EC TYPE EXAMINATION (Module B) CERTIFICATE MARINE EQUIPMENT DIRECTIVE Certificate No.: 0832-MED-1019 MARINE EQUIPMENT DIRECTIVE This is to certify that BRE Global Ltd, as specified as a notified body under the terms of the Statutory Instrument 1999 No. 1957 The Merchant Shipping (Marine Equipment) Regulations

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61514-2 First edition 2004-01 Industrial process control systems Part 2: Methods of evaluating the performance of intelligent valve positioners with pneumatic outputs IEC 2004

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61000-4-8 Edition1.1 2001-03 Edition 1:1993 consolidated with amendment 1:2000 BASIC EMC PUBLICATION Electromagnetic compatibility (EMC) Part 4-8: Testing and measurement techniques

More information

REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO Dean King Dean King November 16, 2012

REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO Dean King Dean King November 16, 2012 AC200032 AGENCY DOCUMENTS, ET1528L Third Edition REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO-12-020164 Dean King Dean King November 16, 2012 DOC #: AC200032 Print

More information

Technical-Report for SL Lamp 5 W

Technical-Report for SL Lamp 5 W Technical-Report for SL Lamp 5 W Technical Report No. 68.184.17.478.01 Dated 2017-06-27 Client: Manufacturing place: Name: PHOCOS China Ltd. Address: 3F 1st Bldg. 4A Chang Yi Road, 266021, Qingdao, PEOPLE'S

More information

EC TYPE EXAMINATION (Module B) CERTIFICATE MARINE EQUIPMENT DIRECTIVE Certificate No.: 0832-MED-1011

EC TYPE EXAMINATION (Module B) CERTIFICATE MARINE EQUIPMENT DIRECTIVE Certificate No.: 0832-MED-1011 MARINE EQUIPMENT DIRECTIVE This is to certify that BRE Global Ltd, as specified as a notified body under the terms of the Statutory Instrument 1999 No. 1957 The Merchant Shipping (Marine Equipment) Regulations

More information

Supplementary Installation and Operating Instructions. Category II2G

Supplementary Installation and Operating Instructions. Category II2G Supplementary Installation and Operating Instructions Flap-type Flow Meter Category II2G 2 Contents 1. General safety directions...3 2. Main safety-relevant characteristics...4 2.1. Category / Zone...4

More information

XB-EFA-8L-BK & XB-EFA-8R-BK

XB-EFA-8L-BK & XB-EFA-8R-BK Supply & Extract Ventilation Unit with Heat Recovery The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU The information contained in this document provides details of installation, operation

More information

MO n : 12JMC rév A

MO n : 12JMC rév A CTT8 MO n : rév A Page 2 / 18 MODIFICATIONS Rev. Description Date Checked by Approuved by Z Creation 2012/02/12 JMC LA A First issue 2012/02/14 JMC LA INDEX Page 3 / 18 GENERALITY 4 INTRODUCTION 4 ACCESSORIES

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

EC TYPE EXAMINATION (MODULE B) CERTIFICATE EC TYPE EXAMINATION (MODULE B) CERTIFICATE This is to certify that: LLOYD'S REGISTER VERIFICATION LIMITED (LRV), specified as a notified body under the terms of The Merchant Shipping (Marine Equipment)

More information

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel December 5th, 2017 Acceptance Requirements Fibre Optic Systems Revised 12/2017 Alexander Kölbel +49 6190 8880-40 alexander.koelbel@datwyler.com Dätwyler Cables GmbH, Auf der Roos 4-12, 65795 Hattersheim,

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual H-IM-LLC February 2018 Part No. 25092501 Replaces H-IM-LLC (01/2014) Lead Lag Control System Table of Contents General Safety Information 2 Inspection 2 Warranty Statement

More information

Refrigerated Incubator Model and Operating Instructions

Refrigerated Incubator Model and Operating Instructions Refrigerated Incubator Model 165000 and 165000-2 Operating Instructions N2400379 - Rev. 1 08May2018 1 Contents 1. SAFETY...3 1.1. EMF INTERFERENCE...4 1. PRODUCT INFORMATION...5 1.1 INTRODUCTION...5 2.

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY Seville, 31.03.2016 Pedro Martin, RadLab Radiation Facility Supervisor TÜV NORD GROUP QUALITY ASSURANCE AND SAFETY «Anything that can go

More information

Additional deviations may possibly be found if a complete type test is carried out on the product.

Additional deviations may possibly be found if a complete type test is carried out on the product. Diary No. 13EV4171 Reference No 1315333 MARKET SURVEILLANCE TEST REPORT - LVD The tests cover parts of the requirements for AC adapter stated in the standard SS-EN 60950: 2006 + A11 + A1 + A12 and EN 50075.

More information

IQ/OQ Protocol Installation Qualification/ Operation Qualification

IQ/OQ Protocol Installation Qualification/ Operation Qualification IQ/OQ Protocol Installation Qualification/ Operation Qualification FlaskScrubber Vantage TM Series Glassware Washer Labconco o: 1058701 Rev. B Available at www.labconco.com or by e-mail in Word 2000 document

More information