MODEL MP-1S OVERSPEED UNIT
|
|
- Lizbeth Henry
- 5 years ago
- Views:
Transcription
1 MODEL MP-S OVERSPEED UNIT SPEIFIATIONS Model Spec. ode upon delivery/add l Spec. ode( not requested, leave blank ) MP-S Hysteresis Set up Monitor Range Input Signal No. of Input Pulse Trigger Mode (Shaped Waveform circuit) 2 to 2,000 rpm RD, FK Series 0 4 to 20m AD to 255 pulse / no. of revolutions Auto 0.5V 0 Not provided 3 to 4,000 rpm 2 MS Series to 5 VD Ex.) =00 2 Manual 2.0V Provided 4 to 5,000 rpm H5 Series 3 2.0V 3 Note: In case MS is input, Short-circuited Detection is not possible. 5 to 0,000 rpm (AIRPAX o.) In case H5 Series is input, Input Abnormality detection is not possible. 6 to 5,000 rpm 7 to 20,000 rpm Alarm Reset Alarm Reset Alarm Reset START-UP TIMER Function System Group* (TRP) (ALT) (NOT-OK) (TRP) (ALT) (NOT-OK) 0 Not provided 0 Auto-Reset 0 Auto-Reset 0 Auto-Reset 0 Normally De-energized 0 Normally De-energized 0 Normally De-energized A Provided Self-Hold Self-Hold Self-Hold Normally Energized Normally Energized Normally Energized 2 B 3! Warning Note) * hose the same group code on each unit used for a system as This unit should not be used for the purpose of controlling the system, because the response of "2 out of 3" or "2 out of 2" in a same rack. the is slow. should be used for the purpose of data recording.! Danger In case the Overspeed Protection System is designed to be used with this unit, use the redundant system consisting of three units (corresponding to 2 out of 3). For highest reliability, use other meters or machinery protection equipment to design the system. In case the machine protection is performed using a single meter, and that meter is experiencing a problem, it may cause severe injury or damage to the equipment. Input No. of Revolutions In case the Indicated No. of Revolutions differs from the Input Overspeed Set Point 2 points (TRP, ALT) / Indicated No. of No. of Revolutions, fill in the numbers below. Overspeed Set Range an be setup in rpm increments up to 000rpm to 00% of Revolutions When the Input No. of Revolutions is rpm, monitor range. Ratio hange rpm. Overspeed Set Accuracy ± rpm or less (Not Standard In case the magnification is or more, the accuracy resolution ABNOR. Alarm Output point (NOT-OK) Specifications) becomes worse in proportion to the magnification number. Rotation Measured LED Digital meter with 5 digits (7 segments) hangeable Range: 0.00 (Indicated No. of Revolutions / Input No. of Revolutions) Value Overspeed Setup Value TRP : ALT : Trigger Indicator TRG. : (Red LED) However, TRP ALT. If unspecified, 50% of delivered monitor range. Shift Key Select Indicator SHIFT : (Red LED) Overspeed Relay Hysteresis an be setup within the range 0 to 50 rpm ( rpm Increments) TRP : Input RD, FK Series, MS Series, H5 Series (AIRPAX o.) ALT : Input Impedance About 5 kω If unspecified, 0 rpm when delivered. Input Voltage Range 300 Vpk-pk or less an be setup within the range 5 to 50% of F.S.(5% Increments) Min. Input Pulse Width 5 µs Setup value : Min. Indicated frequency 0 Hz Dimension(Model RD,FK) No. of Input Pulses to 255 pulse D B A D A D B External ontact Input ontact Type : Dry contact ontact for External Reset ontact for Lamp Test ontact for START-UP Timer ontact for TRP Alarm BYPASS Note: A should not be flat. Make the curve along a concentric circle. A= mm B= mm = mm D= mm Input RD-05A FK-202F A 6 B (mm) D 6 Dimension of Target Recommended Set Gap Setup Value(mm).0 to.5 Digital Indicated Accuracy onversion Accuracy Pulse Output ±(0.003% of rdg. + digit) at 25 ±(0.03% of rdg. + digit) at 0 to 60 Voltage or current output proportional to monitor range. to 5VD (Output Impedance : 250Ω) 4 to 20mAD (Max. Load Resistance : 600Ω) Number of Output Point : point ±0.5% of F.S. at 25 ±2.0% of F.S. at 0 to 60 Pulse Output : Shaped pulse signal is output via a buffer amplifier. Signal Level : - to +V(P L ), +4 to 6V(P H ) Output Impedance : About 00Ω -24VD±V, 20mA (RD,FK specified) +2VD±V, 50mA (H5 specified) (Provided 9V to 27 VD s from the bass-line in the Alarm ontact Output Output Point : TRP : 2 points Instrument Rack) : ALT : 2 point Temperature Range Operating Temperature : 0 to 60 : NOT-OK : point Storage Temperature : -30 to +85 ontact apacity : Resistance Load : 250VA, 5 A Relative Humidity : 20 to 95%RH (noncondensing) : 30VD, 5A Face Plate Finish Munsell N-.0 (equiv.) ontact Type : ontact, Dry ontact Mass Max. 2.0kg Response Time : 30 ms at 300Hz or more E Marking onform to E requirements when MP-P2 is used for power supply unit. ondition TRP ontact ALT ontact Not-OK ontact Indication After PU Abnormality Detection 0 V (0mA) Input abnormal Detection Input Abnormal Indication 0 V (0mA) TRP Information Sent TRP Indication Measured Value ALT Information Sent ALT Indication Measured Value On-line Test (ontact Output Mode) On-line Test Indication Test Value On-line Test (ontact ontrol Mode) On-line Test Indication Test Value Unit Removal All ontacts Open All ontacts Open All ontacts Open 0 V (0mA) : Information Sent : Output ontrol : No relation ship 39803E.9 Revised : Dec.2009
2 MP- Series Monitor Specifications MODEL MP-Z ZEROSPEED UNIT Model Spec. ode upon delivery / Add l Spec. ode ( not requested, leave blank ) MP-Z- - - Hysteresis Set up Input Signal No. of Input Pulse* (shaped Waveform circuit) RD, FK Series 0 4 to 20mAD to 20 pulse / no. of revolutions 0.5V 0 Not Provided H5 Series to 5VD Ex.)=00 2.0V 3 Periods of Zerospeed setup value 2 (AIRPAX o.) 3 2.0V 2 5 Periods of Zerospeed setup value Note: In case H5Serise is input, Input Abnormality detection is not possible. - - Note) * 20 P/R or more is recommended. *2 hose the same group code on each unit used for a system as "2 out of 3" or "2 out of 2" in a same rack. Alarm Reset Alarm Reset Alarm Reset (Z) (Z2) (NOT-OK) (Z) (Z2) (NOT-OK) System Group*2 0 Auto-Reset 0 Auto-Reset 0 Auto-Reset 0 Normally De-energized 0 Normally De-energized 0 Normally De-energized A Self-Hold Self-Hold Self-Hold Normally Energized Normally Energized Normally Energized 2 B 3! Warning This unit should not be used for the purpose of controlling the system, because the response of the is slow. should be used for the purpose of data recording. In case the Zerospeed system is designed to be used with this unit, for the safety and reliability of the turning gear apparatus, use s redundant system consisting of 3 units (corresponding to 2 out of 3). For the highest reliability, it is recommended to design the system with other fast shut-down conditions. Input No. of Revolutions In case the Indicated No. of Revolutions differs from the Input Zerospeed Set Point 2 points (Z, Z2) / Indicated No. of No. of Revolutions, fill in the numbers below. Zerospeed Set Range an be setup in 0. rpm increments within the range 0.0rpm Revolutions When the Input No. of Revolutions is rpm, to 99.99rpm. Ratio hange rpm. Zerospeed Set Accuracy ± 0.0rpm or less (Not Standard In case the magnification is or more, the accuracy resolution ABNOR. Alarm Output point (NOT-OK) Specifications) becomes worse in proportion to the magnification number. Rotation Measured LED Digital meter with 5 digits (7 segments) hangeable Range: 0.00 (Indicated No. of Revolutions / Input No. of Revolutions) Value Zerospeed Setup Value Z : Z2 : Trigger Indicator TRG. : (Red LED) However, the following conditions must be satisfied. Z Z2 Shift Key Select Indicator SHIFT : (Red LED) 0.0rpm Z,Z rpm 0.6/Nrpm Z,Z2 N: No.of Input Pulses(pulse / revolution) If unspecified, rpm when delivered. Input Input Impedance RD, FK Series, H5 Series (AIRPAX o.) About 5 kω Zerospeed Relay Input Voltage Range 300 Vpk-pk or less Hysteresis an be setup within the range 0 to 50 rpm ( rpm Increments) Min. Input Pulse Width 5 µs Z : Min. Indicated frequency 0.0 Hz Z2 : If unspecified, rpm when delivered. No. of Input Pulses to 20 pulse Trigger Mode Manual Trigger Dimension(Model RD,FK) D B A D A D B External ontact Input ontact Type : Dry contact ontact for External Reset ontact for Lamp Test ontact for Zerospeed BYPASS Digital Indicated Accuracy ±(0.003% of rdg. + digit) at 25 ±(0.03% of rdg. + digit) at 0 to 60 Note: A should not be flat. Make the curve along a concentric circle. Input A= mm B= mm = mm D= mm Dimension of Target Recommended RD-05A FK-202F A 6 B (mm) D 6 Set Gap Setup Value(mm).0 to.5 onversion Accuracy Pulse Output Voltage or current output proportional to the range 0 to 00rpm. to 5VD (Output Impedance : 250Ω) 4 to 20mAD (Max. Load Resistance : 600Ω) Output Point : point ±0.5% of F.S. at 25 ±2.0% of F.S. at 0 to 60 Pulse Output : Shaped pulse signal is output via a buffer amplifier. Signal Level : - to +V(P L ), +4 to 6V(P H ) Output Impedance : About 00Ω -24VD±V, 20mA (RD, FK specified) +2VD±V, 50mA (H5 specified) (Provided 9V to 27 VD from the bass-line in the s Instrument Rack) Zerospeed ontact Output Point : Z : 2 points Temperature Range Operating Temperature : 0 to 60 Output : Z2 : 2 points Storage Temperature : -30 to +85 : NOT-OK : point Relative Humidity : 20 to 95%RH (noncondensing) ontact apacity : Resistance Load : 250VA, 5 A Face Plate Finish Munsell N-.0 (equiv.) : 30VD, 5A Mass max. 2.0kg ontact Type : ontact, Dry ontact E Marking onform to E requierements when MP-P2 is used for power unit. ondition Z ontact Z2 ontact Not-OK ontact Indication After PU Abnormality Detection 0 V (0mA) Input Abnormal Detection Input Abnormal Indication 0 V (0mA) Zerospeed Detection Zerospeed Detection Indication Measured Value On-line Test (ontact Output Mode) On-line Test Indication Test Value On-line Test (ontact ontrol Mode) On-line Test Indication Test Value Unit Removal All ontacts Open All ontacts Open All ontacts Open 0 V (0mA) : Information Sent : Output ontrol : No relation ship 39804E2.0 Revised : Jan. 202
3 MODEL MP-T THRUST UNIT SPEIFIATIONS Model Spec. ode upon delivery/add l Spec. ode ( not requested, leave blank ) MP-T- 0 - Monitor Range Input Signal Frequency Response Polality* -0.5mm to 0 to +0.5mm VK-202A,FK-202F 0 D to 0.5Hz(-3dB) Direct 4 to 20mAD 0 Not Provided 2 -mm to 0 to +mm 2 VK-452A,FK-452F 2 Reverse 2 to 5VD Provided 3-2mm to 0 to +2mm 3 VK-302P Note) * 4-25mils to 0 to +25mils 4 VK-602P 5-40mils to 0 to +40mils 6-80mils to 0 to +80mils Note) When using Monitor Range 2 (-.0 to 0 to +.0mm) or 5 (-40 to 0 to +40mils), combined with input signal and Intrinsically Safe Explosion Proof onstruction, the OK Alarm Setup Point falls within the range. Therefore, use the monitor within 90% of the range /EX Polality Indication and Recorder output Toward sendor Away from sensor Direct Increase Decrease Reverse Decrease Increase Alarm Reset Alarm Reset Alarm Reset Alarm Delay Time Alarm Delay Time Sensitivity System Group*2 (TRP) (ALT) (NOT-OK) (TRP) (ALT) (NOT-OK) (TRP) (ALT) correction 0 Auto-Reset 0 Auto-Reset 0 Auto-Reset Normally 0.sec. 0. sec. A TIIS 0 Self-Hold Self-Hold Self-Hold De-energized 0 Normally De-energized 0 Normally De-energized 2 sec. 2 sec. 2 B 2 FM Normally Normally Normally 3 2 sec. 3 2 sec. 3 4 SA Energized Energized! Danger In case the Machine Protection System is designed to be used with this unit, use the redundant system consisting of three units (corresponding to 2 out of 3). For highest reliability, use other meters or machinery protection equipment to design the system. In case the machine protection is performed using a single meter, and that meter is experiencing a problem, it may cause severe injury or damage to the equipment. Alarm Set Point HH : H : L : LL : If unspecified, H-DANGER : 00% of delivered monitor range. H-ALERT : 90% of delivered monitor range. L-ALERT : 0% of delivered monitor range. L-DANGER : 0% of delivered monitor range. s an be setup within the range 0 to 50% of F.S. (0% Increments) Setup value : Alarm ontact Output Output Point : TRP : 2 points : ALT : 2 points Energized 4 3 sec. 4 3 sec. 5 ATEX 5 5 sec. 5 5 sec. 7 NEPSI Measured Value LED Digital meter with 5 digits (7 segnents) Shift Key Select Indicator SHIFT : (Red LED) Input VK-202A, FK-202F, VK-302P, VK-452A, FK-452F, VK-602P Input Impedance About 50kΩ External contact Input ontact Type : Dry ontac t ontact for External reset ontact for Lamp Test ontact for TRP Alarm BYPASS Zero Shift Adjustable within 0 to 00% of monitor range Digital Meter ±.0% of F.S. at 25 ±0.5% of F.S. at 25 onversion Accuracy ±2.0% of F.S. at 0 to 60 Note) *2 hose the same group code on each unit used for a system as "2 out of 3" or "2 out of 2" in a same rack. Voltage or current output proportional to monitor range. to 5VD (Output Impedance : 250Ω) 4 to 20mAD (Max. Load Resistance : 600Ω) Output Point : point -24VD±V, 20mA : NOT-OK : points (Provided 9V to 27 VD ontact apacity : Resistance Load : 250VA, 5A from the bass-line in the : 30VD, 5A Instrument Rack) ontact Type : ontact Dry ontact Temperature Range Operating Temperature : 0 to 60 Alarm Set Point 4 points (HH, H, L, LL) Storage Temperature : -30 to +85 Alarm Set Range -0 to +0% of monitor range Rslative Humidity : 20 to 95%RH (noncondensing) Alarm Set Accuracy ±.0% of F.S. or less Face Plate Finish Munsell N-.0 (equiv.) Alarm Set Repeatability ±0.% of F.S. or less Mass max.2.0kg Alarm Output point (NOT-OK) E Marking onform to E requirements when MP-P2 is used for power supply unit. ondition TRP ontact ALT ontact Not-OK ontact Indication After PU Abnormality Detection 0 V (0mA) Input abnormal Detection Input Abnormal Indication Measured Value TRP Information Sent TRP Indication Measured Value ALT Information Sent ALT Indication Measured Value On-line Test (ontact Output Mode) On-line Test Indication Test Value On-line Test (ontact ontrol Mode) On-line Test Indication Test Value Unit Removal All ontacts Open All ontacts Open All ontacts Open 0 V (0mA) : Information Sent : Output ontrol : No relation ship E.9 Revised : Dec.2009
4 SPEIFIATIONS MODEL MP-P POWER SUPPLY UNIT Voltage Regular, Backup 85 to 264VA Regular 2 24VD 2 Backup 3 48VD 4 0VD Indicator OK Indicator : Green LED Output Alarm ontact Output ontact Type : P-OK (to supply power to bassline ontact apacity : 250VA, 5A in Instrument Rack) : 30VD, 5A Insulation Resistance ontact Type : contact Dry contact Normally energized Alarm Reset ontact Life Protective onstruction Model Spec. ode upon delivery / Add l Spec. ode ( not requested, leave blank ) Auto-reset 00,000 times or more (rated load) Plastic seal MP-P Regular : 26V± VD Backup : 24V±VD Between power supply & GND : 00M or more at 500VD Between power supply & alarm contact : 00MΩ or more at 500VD Between GND & alarm contact : 00MΩ or more at 500VD Dielectric Strength Between power supply & GND MP-P : 2,000VA, min. MP-P2 : 2,000VA, min. MP-P3 : 2,000VA, min. MP-P4 :,500VA, min. Power onsumption MP-P : 20VA or less MP-P2 : 00W or less MP-P3 : 00W or less MP-P4 : 00W or less Temperature Range Operating Temperature : 0 to 60 Storage Temperature : -30 to +85 Relative Humidity : 20 to 95%RH (non-condensing) Finish Panel : Munsell N-.0 (equiv.) Mass Max. 2.0kg E Marking Only as for MP-P E.3 Revised : Apr.2004
5 SPEIFIATIONS MODEL MP-W INSTRUMENT RAK Model Spec. ode upon delivery/add l Spec. ode( not requested, leave blank ) MP-W - No. of Mounted Units * ombination Max. 3 Units 0 D A 2 Max. 6 Units D D 2 A A * Unit is not included. Input for Operation External Reset (normally open) Lamp Test (normally open) Start-up Timer (short circuit between terminals: START; open between terminals: STOP) TRP / Zerospeed Bypass (normally open) ontact Type : Dry contact Temperature Range Operating Temperature: 0 to 60 Storage Temperature: -30 to +85 Relative Humidity: 20 to 95%RH (non-condensing) Finish Rack: Munsell N-.0 (equiv.) Weight MP-W: max.7kg MP-W2: max.0kg E Marking onform to E requierements when MP-P2 is used for power unit E.4 Revised : Dec.202
VM-702B ABSOLUTE VIBRATION MONITOR MODULE Page 1 of 5
Page 1 of 5 No entry if additional Model Code / Additional Spec. Code ( spec. code is not specified. ) VM-702B /ALY /NB1 /CS1 /CS2 /TRP /TB Analysis Function Non-incendive * 1 Monitor Function Analysis
More informationVM-5 SERIES MONITOR INSTRUCTION MANUAL
MANUAL. 29507E4.0 Published in Jun.1996 Revised in Aug.2009 VM-5 SERIES MONITOR MODEL VM-5T DUAL THRUST MONITOR INSTRUCTION MANUAL SAFETY CONVENTIONS VM-5T For safe operation... Thank you for using our
More informationVM-5 SERIES MONITOR. MODEL VM-5P3 Phase Marker Unit INSTRUCTION MANUAL
MANUAL NO. 20002E2.0 Published in Dec.2000 Revised in Nov. 2012 VM-5 SERIES MONITOR MODEL VM-5P3 Phase Marker Unit INSTRUCTION MANUAL SAFETY CONVENTIONS VM-5P3 For safe operation... Thank you for using
More informationVM-15 SERIES MONITOR. Model VM-15U1 VELOCITY MONITOR INSTRUCTION MANUAL
MANUAL No. 20203E2.4 Published in Jul.2002 Revised in Mar.2012 M-15 SERIES MONITOR Model M-15U1 ELOCITY MONITOR INSTRUCTION MANUAL FOREWORD M-15U1 FOR THE SAFE OPERATION OF THIS UNIT Thank you for using
More informationVM-5 SERIES MONITOR MODEL VM-55 VIBRATION MONITOR INSTRUCTION MANUAL
MANUAL.20501E2.1 Published in Mar.2005 Revised in Jul.2010 VM-5 SERIES MONITOR MODEL VM-55 VIBRATION MONITOR INSTRUCTION MANUAL SAFETY CONVENTIONS VM-55 For safe operation... Thank you for using our VM-5
More informationSA100L. General Description. Features. Temperature Limit Controller SA100L. Simple Mounting on DIN Rail. Over/Under Temperature Protection
SA00 SA00 SA00 SA00 Temperature Limit ontroller SA00L FM APPROVED SA00L General Description The SA00L is a FM approved high limit or low limit controllers. The SA00 is a socket mounting type temperature
More informationVM-15 SERIES MONITOR INSTRUCTION MANUAL
MANUAL No. 20202E2.6 Published in Jul.2002 Revised in Oct.2012 M-15 SERIES MONITOR Model M-15B1 ACCELERATION MONITOR INSTRUCTION MANUAL FOREWORD M-15B1 FOR THE SAFE OPERATION OF THIS UNIT Thank you for
More information4TEMPERATURE CONTROLLER
Universal Input Output and High Accuracy 0.5 class 250ms TEMPERATURE ONTROLLER RAMP function PID Auto-tuning Universal input /, Reverse/Direct action selectable Remote/Local input selectable Model and
More informationSA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting
Temperature Controller General Description The is a high performance 3 nd DI controller that has been specifically designed for applications where panel space is critical. Though small in size, this controller
More informationDTM Distributed Transmitter-Monitor
DTM Distributed Transmitter-Monitor DTM10 Proximity Distributed Transmitter-Monitor (Shaft Vibration, Thrust Position and Speed) The DTM10 distributed vibration transmitter-monitor is ideal for monitoring
More informationSentry G3 Machinery Protection Monitor
TECHNICAL INFORMATION Sentry G3 Machinery Protection Monitor CONDITION MONITORING SOLUTIONS The Sentry G3 Machinery Protection Monitor is a high performance signal conditioning unit; providing a universal
More informationMODEL: 47LPQ. Digital Panel Meters 47 Series. [3] ALARM OUTPUT 0: None 1: N.O. relay contact, 4 points 2: SPDT relay contact, 2 points
Digital Panel Meters 47 Series PULSE INPUT TOTALIZER (6-digit, LED display type) Functions & Features 6-digit digital panel meter 1/8 DIN size Process integration/totalization with scaling factor adjustment
More informationSentry G3 Machinery Protection Monitor
TECHNICAL INFORMATION Sentry G3 Machinery Protection Monitor CONDITION MONITORING SOLUTIONS The Sentry G3 Machinery Protection Monitor is a high performance signal conditioning unit; providing a universal
More informationAUR300C. Advanced Ultraviolet Burner Controller
No. CP-SS-1807E AUR300C Advanced Ultraviolet Burner Controller Overview The AUR300C is a burner controller with a dynamic selfchecking function and is used in combination with the AUD300C or AUD500C Advanced
More informationSHIMADEN DIGITAL INDICATORS
Shimaden, Temperature and Humidity Control Specialists C %RH MICROPROCESSOR-BASED SHIMADEN DIGITAL INDICATORS & NRTL /C approved BASIC FEATURES DIN Size 48 x 96 mm ±.25% High Accuracy Indication User-Selectable
More informationTemperature Controllers
Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65
More information02/11/2015
CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint
More information3. Compatible Sensor Wiring 4. Batch Contact Wiring See section 9 for simple and advanced mode configuration options.
GF SIGNET ontroller Instructions 3.0901 B1/98 ENGLISH AUTION! Refer to this instruction manual for more details. Remove power to unit before wiring input and connections. Follow instructions carefully
More informationAdvanced Ultraviolet Burner Controller
No. CP-SS-7E Advanced Ultraviolet Burner Controller Model AUR300C/AUR30C Overview The AUR300C Advanced Ultraviolet Burner Controller and AUR30C Advanced Ultraviolet Burner Controller with Communication
More informationThermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery
Thermo Scientific Ramsey TM Series 60-200 Sensing Speed Conditions on Rotating Shafts and Machinery The Thermo Scientific Ramsey Series 60-200 monitors under-speed, overspeed and zero-speed conditions
More informationSA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail
Temperature Controller General Description The is a socket mounting type temperature controller and is available for mounting inside the panel or by easily mounting on DI rail. The has features such as
More informationMODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power
Digital Panel Meters 47 Series THERMOCOUPLE INPUT DIGITAL PANEL METER (4-digit, LED display type) Functions & Features 4-digit thermocouple input digital panel meter 1/8 DIN size Moving average function
More informationMODEL: 47LCT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White
Digital Panel Meters 47 Series CT DIGITA PANE METER (4½ digit, ED display type, true RMS sensing) Functions & Features 4 ½ digit CT input digital panel meter 1/8 DIN size Moving average function to suppress
More information02/11/2015
MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS
More informationRamsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery
Ramsey Series 60-200 Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery Ramsey Series 60-200 Motion Monitoring Systems offer versatile and reliable packages
More informationAUR300C, AUR350C. Advanced Ultraviolet Burner Controller
No. CP-SS-7E Overview The AUR300C is a burner controller with a dynamic selfchecking function and is used in combination with the AUD300C or AUD00C Advanced Ultraviolet Flame Detector. This AUR300C controls
More information7EF/7HF/7EC/7ES Temperature Controllers
7EF/7HF/7E/7ES Temperature ontrollers Dual 4 Digit LED Display Universal Input (6 T/, RTD, mv, V, ma) Autotuning NEMA 4X 100 to 240 Vac Switching Power Supply Algorithms for Heat or Heat/ool ontrol 2 Independent
More informationSpeed and Frequency Seite 1 von 7
Speed and Frequency Seite 1 von 7 E16 Systems for High Safety Speed ing, all with Triple Modular Redundancy. A choice of versions to meet various demands. Compliant with SIL3 / IEC 61508 and/or API 670.
More informationTEMPERATURE CONTROLLER
TEMPERATURE CONTROLLER E5CX(-H) DIN-sized super-compact (48 x 48-mm) Temperature Controller Featuring Advanced PID Control Advanced PID control with two degrees of freedom improves stability and response
More informationRamsey Motion Monitoring Systems
Ramsey Motion Monitoring Systems 60-200 Motion Monitoring Accurate Sensing of Underspeed, Overspeed and Zero Speed Conditions on Rotating Shafts and Machinery The Ramsey Series 60-200 Motion Monitoring
More informationINSTALLATION INSTRUCTIONS EA SERIES DOOR PROP/EXIT ALARM
80 Avenida Acaso, amarillo, a. 90 (80) 9-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUTIONS EA SERIES DOOR PROP/EXIT ALARM Model EA-SN Model EA-78 Model EA-708 (cylinder not
More informationAO Annunciator Module
General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,
More informationPS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3
F1! DANGER 44487056 These instructions cover the following parts: PS914 Power Supply Installation Instructions! DANGER: To avoid risk of electric shock, turn off A power before installing or servicing
More information- Data Brochure Boiler Control 274
- Data Brochure Boiler Control 274 274_D 03/17 The Boiler Control 274 operates up to four on/off boilers to provide outdoor reset operation, domestic hot water and setpoint operation with priority. When
More informationTempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications
Instruction Manual Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications Manual PCT30006, Revision 9/20/2016 The PCT30006 control enclosure incorporates
More informationCLEANROOM MONITOR CR3A Network - Installation Instructions
CLEANROOM MONITOR CR3A Network - Installation Instructions INTRODUCTION The CR3 Series Cleanroom Monitor, was developed specifically to allow for monitoring of confined spaces with accuracy and reliability.
More informationDB5 Intrinsically Safe Sounder Type DB-5
Operating Instructions RTK Instruments Limited DB5 Intrinsically Safe Sounder Type DB-5 Description The DB5 Sounder is a strong, lightweight warning sounder, CENELEC certified to Ex II 1G EExia IIC T4
More informationDS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM
DS 96/48 P Digital indicator Short manual 41/33-89 EN Rev. 00 A1 A2 DIM E 1 Safety instructions Correct and safe operation of the apparatus calls for expert installation and meticulous maintenance. This
More informationMICRO CONTROLLER S Z SERIES
Instruction Manual MICRO CONTROLLER S Z SERIES TYPE: PYW 4 5 7 9 Fuji Electric Co.,Ltd. INP-TN1PYWf-E INTRODUCTION You are now the owner of Fuji's digital Temperature Controller. Before using, be sure
More informationInstallation Manual Tracker 221
Installation Manual Tracker 221 KSR KUEBLER AG Im Kohlstatterfeld 17 D-69439 Zwingenberg / Germany www.ksr-kuebler.com Contents About this Installation Manual...4 Description Tracker 220-series...4 Installing
More informationFUNCTIONAL SAFETY MANUAL
FUNCTIONAL SAFETY MANUAL UltraSonic EX-5 Ultrasonic Gas Leak Detector The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent
More informationTAIE. Features. FY600 (96mm X 48mm) Application:Control temperature,humidity, FY Series Digital PID Controller
TAIE FY Series Digital PID Controller FY600 (96mm X 48mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy
More informationDIGITAL METERS Large Display Temperature Meters Instruction Manual
DIGITAL METERS Large Display Temperature Meters PD755 PD756 PD757 Handles Thermocouple & RTD Inputs with Simplicity J, K, T, E, R, & S Thermocouples 100 Ω Platinum RTD (0.00385 or 0.00392 curve) Large
More informationc0094 form 2. Project Identification Year: 2001 Project nº: 910
1. History of processing of this form v1 Jul 19, 2001 by JN RBI 4 Stage Boiler Control. v2 Aug 7, 2001 by JN Packaging of BTC and 071 Sensors, and finalized mounting option, etc. v3 Aug 29, 2001 by JN
More information(Except 12-24VDC) Control output 12-24VDC. Power consumption Max. 8W Max. 4VA Max. 8W Max. 4VA Max. 8W Max. 4VA
TC3YF Freezing/ type DIN W72 H36mm Freezing/ type Features ON/ Control Input specification - Basic specification: NTC(Thermistor), Option: RTD(DPt100Ω) Temperature display range NTC type: -40.0 to 99.9
More informationcondition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers
WP4086 Condition Monitoring System WP4086 Condition Monitor Accelerometer Measuring Points The WP4086 CMS System surveys vibrations with up to 8 external accelerometers Real-time sample, calculation and
More informationGeneral Specifications
General Specifications GS J0H-0E Model MVHK Digital Limit Alarm (DC Type) with Active Color PV Display General This plug-in type Digital Limit Alarm for DC input receives DC current or DC voltage signal.
More informationTAIE. Features. FY900 (96mm X 96mm) Application:Control temperature,humidity, FY Series Digital PID Controller
TAIE FY Series Digital PID Controller FY900 (96mm X 96mm) Application:Control temperature,humidity, FY series controllers are microprocessor based controllers. Which have been Designed with high accuracy
More informationCode 2. A AC/DC 100~240V N None
5 DIGIT MIO-POESS PULSE INPUT FLOW METE with ~ AMS / ANOG OUTPUT / S-85 + FEATUES Accuracy: + - 0.0% F.S. High brightness 0.8" LED display: 0~99999; decimal point selectable! Flow unit selectable: Liter
More informationSAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .
CALIB CONTINUOUS SPEED INDICATOR EVALUATION UNIT ALRM 1 ALRM 2 ALRM 3 PULSE DISPLAY MESSAGES INSTRUMENT START/RESTART OVERSPEED OCCURED > UNDERSPEED OCCURED < SPEED IS
More informationWP4086 Condition Monitoring System
WP4086 Condition Monitoring System WP4086 Condition Monitor The WP4086 CMS System surveys vibrations with up to 8 external accelerometers Real-time sample, calculation and storage of vibration signals,
More informationAL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER
AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER MODEL AL3 7 5 - AL3000 series conforming to CE, UL and CSA are 100mm multi-point type hybrid recorders with a simultaneous display of multi-channel
More informationMicro-controller X C C1 C2 AL1 AL2 AL3. Model: PXR4/5/9. Operation Manual SEL PXR. ECNO:406e
C C1 C2 AL1 AL2 AL3 Micro-controller X Model: PXR4/5/9 PXR SEL Operation Manual ECNO:46e Table of Contents Part Names and Functions... 6 Operations... 7 2-1 Parameter list... 7 2-2 Basic operations...
More informationZ24 Wireless Zone Controller Professional Installation Guide
Pelican Wireless Systems Pelican Wireless Systems Wireless Zone ontroller Professional Installation Guide Pelican Wireless Systems, 2655 ollier anyon Rd. Livermore, A 94551 Phone: 888.512.0490 Email: support@pelicanwireless.com
More informationR Air flows from high pressure side to low pressure side. This principle can be applied to keep clean-air in the room or, alternatively, not to leak p
The first edition contrasted April 2011 Yamamoto Electric Works Co.,Ltd. T H E G E N E R A L C A T A L O G R We appreciate the importance of air. Manostar gage h t t p : / / w w w. m a n o s t a r. c o.
More informationELECTRONIC HUMIDISTAT: H270
ELECTRONIC HUMIDISTAT: H0 ONE OR TWO STAGES HUMIDITY SUPPLY OUTDOOR TEMPERATURE RESET DESCRIPTION The H0 series low voltage, microcomputerbased PI (proportional and integral) humidistats are designed for
More informationPower Controller THV-A1 Series
Power Controller THV- Series (2,3,,,8, type) THV- General Description s the THV- single phase power control unit can be used with control modes selectable from constant, constant and constant power, it
More informationTable of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11
Table of Contents 1. OVERVIEW... 3 2. SYSTEM LAYOUT... 4 3. SPECIFICATIONS... 8 3.1 SYSTEM COMPONENTS...9 3.2 PLC INPUTS AND OUTPUTS...9 3.3 FUNCTION KEYS...10 3.4 DEFAULT SET POINTS AND TIMERS...10 4.
More informationRTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals
Technical Information RTA421 Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals Application Plant and machine construction Panel builders Process monitoring Process
More informationDigital Heater Element Burnout Detector K8AC-H
Digital Heater Element Burnout Detector K8AC-H A high-precision Heater Element Burnout Detector compatible with a wide-range of heater control methods. Push-in terminals reduce the workload. *1 Scaling
More informationELECTRONIC HUMIDISTAT: H200
ELECTRONIC HUMIDISTAT: H00 ONE OR TWO STAGES DESCRIPTION The H00 series low voltage, microcomputerbased PI (proportional and integral) humidistats are designed for accurate humidification and/or dehumidification
More informationI/A Series 716C 1/16 DIN Temperature Controller
Product Specifications I/A Series 716C 1/16 DIN Temperature Controller PSS 2C-1B5 A The Foxboro 716C is a powerful compact, 1/16 DIN, microprocessor-based temperature controller that offers a variety of
More informationSTANDARD. Customer : DC FAN. Description : Customer P/N : rev. : N/A X01. Sample issue date : DEC Quantity :
Delta Electronics, Inc. No.252, Shanying Rd., Guishan Dist., TEL : 886-(0)3-3591968 Taoyuan City 333, Taiwan (R.O.C.) FAX : 886-(0)3-3591991 Specification For Reference Customer : Description : STANDARD
More informationDISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS
WITH INTERCONNECT Data Sheet 60.6 NO CONNECT. I / O LOW-V SET NO CONNECT. LED + SUPPLY TIMING RES. FEEDBACK 3 4 5 6 7 NC NC LOGIC OSC. & TIMING DRIVER 0 6 5 4 3 8 V SS GUARD DETECT. IN GUARD SENSITIVITY
More informationTempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications
Instruction Manual Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications Manual PCT-3000 Revision 9/2014 The PCT-3000 series control console incorporates
More informationM2500 Engine Controller Installation Manual
M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...
More informationDanfoss gas detection unit Type GD Heavy Duty
Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx
More information3500/61E & 3500/67E Temperature Monitor
3500/61E & 3500/67E Temperature Monitor Bently Nevada* Asset Condition Monitoring Description The 3500/61E and 3500/67E modules provide six channels and two channel of temperature monitoring. Both monitors
More informationUniversal controller for panel mounting Models CS6S, CS6H, CS6L
Accessories Universal controller for panel mounting Models CS6S, CS6H, CS6L WIKA data sheet AC 85.08 Applications Plant and industrial furnace construction Process engineering Plastics technology and processing
More informationUser's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT
User's Manual Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput Types) Thank you for purchasing the JUXTA Signal Conditioner. Please read through this
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 50 mm non-flush Technical Data specifications Switching element function NAMUR, NC Rated operating distance s n 50 mm Installation non-flush Output polarity NAMUR
More informationD5100 Industrial Differential Pressure Transducer
FEATURES Heavy Industrial CE Approval (amplified only) As Low As ±0.1% Pressure Non Linearity Rugged Construction: Can Withstand 50g Shock/20g Vibration Up to -40 C to +125 C Operating Temperature Range
More informationSTT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009
STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009 Introduction Honeywell s STT 3000 family of microprocessor based transmitters covers the full
More informationRefrigerant Leak Detector Manual
Refrigerant Leak Detector Manual Document No. 70-PHW-1018-R2.4 No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical,
More informationANEMOMETER 4403-RF-BAT
ANEMO 4403 Radio impulsive output Anemometer - Wireless Robust wind speed sensor,extremely resistant and flexible, Suitable for many different application. Stainless steel bearings and high quality technical
More informationM5800 Pressure Transducer with Rotatable Display
Pressure Transducer with Rotatable Display SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and customized Electrical Configurations FEATURES CE Compliance Reverse Polarity Protection
More informationHigh Reliability Of Fiber Optic Amplifier For Convenient Mounting
Fiber Optic Amplifier Reliability Of Fiber Optic Amplifier For Convenient Mounting Features speed response: Max. 0.5ms Auto sensitivity setting (Button setting)/remote sensitivity setting External synchronization
More informationAH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER
AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER MODEL AH3 7 P - - A AH3000 series conforming to CE, UL and CSA are 180mm pen type hybrid recorders with a simultaneous display of multi-channel data,
More informationDSD-3 DIFFERENTIAL SPEED DETECTOR
DSD-3 DIFFERENTIAL SPEED DETECTOR Instruction Manual PL-207 June 1993 PROCESS MEASUREMENTS 33452070 ABOUT THIS MANUAL This manual covers the installation and operation of the DSD-3. It is essential that
More informationPart 3 Troubleshooting
Part Troubleshooting What is in this part? This part contains the following chapters: Chapter See page Troubleshooting 2 Error Codes: Hydro-box 7 Error Codes: Outdoor Units Error Codes: System Malfunctions
More informationNon-contact voltage (for SSR drive): V DC DC current: 4 to 20mA DC Thermocouple: K, J, E Input. RTD: Pt100, JPt100
INSTRUCTI MANUAL Micro-computer based Temperature Indicating Controller 1 GCS-00 No.GCS1E 200.11 To prevent accidents arising from the use of this controller, please ensure the operator receives this manual.
More informationProcess Alarm Module RTA 421
Technical Information TI 074R/24/ae Process Alarm Module RTA 421 Alarm module and power supply for monitoring current or voltage signals Application Areas Plant and machine construction Panel builders
More informationARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER
ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER AI-208 (V7.6) User Manual I. Model Code Symbol The type of AI-208 is made up of 4 parts: AI-208 A G L2 Part 1 (Series) Part 2 (Size) Part 3 (Oupt) Part 4
More informationM7100 Pressure Transducer
SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces
More informationVERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER
1 VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER 1. INTRODUCTION This manual contains information for the installation and operation and tuning of our Vertex VT10 series self-tuning
More informationLaser Collimated Beam Sensor
SERIES Laser Collimated Beam Sensor Class 1 Laser Beam Sensor Safe for Your Eyes Marked Conforming to EMC Directive (Excluding LA-C1) Safe Laser Beam This laser collimated beam sensor conforms to the Class
More informationAnalog Room Pressure Monitor RPC Series
Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the
More informationAutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.
AutomationDirect 1/16 DIN Series Technical Support We strive to make our manuals the best in the industry. We rely on your feedback to let us know if we are reaching our goal. If you cannot find the solution
More informationTachometer/Hourmeter/Trip. Installation and Operation Manual
3211 Fruitland Ave Los Angeles, CA 90058 MTH-103E Tachometer/Hourmeter/Trip Installation and Operation Manual Rev. G P/N 145F-13048 PCO - 00010525 Copyright 2014-2017, Barksdale Inc. All Rights Reserved
More informationREFRIGERATED BATH CIRCULATOR. Instruction Manual. Covers model : LRBC-13C / LRBC-22C. Please read this manual carefully before using the instrument
REFRIGERATED BATH CIRCULATOR Instruction Manual Covers model : LRBC-13C / LRBC-22C Please read this manual carefully before using the instrument Related Products Model Descriptions Capacity Control Range
More informationNov 08 PRODUCT SPECIFICATION SHEET
Honeywell UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS 51-52-03-35 Nov 08 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC1200 & UDC1700 are microprocessor-based 1/16 DIN and 1/8 DIN
More informationCommunications* None RS-232C RS-422 RS-485 BCD Transmission output** (4 to 20 ma)
TEMPERATURE CONTROLLER DIN-sized (96 x 96-mm) Temperature Controller Featuring Advanced PID Control and Heater Burnout Detection Advanced PID control with two degrees of freedom to improve stability and
More informationMODEL: 47NLVT. Digital Panel Meters 47NL Series. POWER INPUT DC Power R: 24 V DC
Digital Panel Meters 47N Series DC INPUT DIGITA PANE METER (4½ digit, ED display type, with terminal block) Functions & Features 4 ½ digit DC input digital panel meter Moving average function to suppress
More informationGas leak detection system. for heating rooms and similar environments. Description. Sensor for methane gas IP44. Sensor for LPG gas IP44
s 7 603 INTELLIGAS Gas leak detection system for heating rooms and similar environments Electronic control unit for gas leak detection with up to 4 sensors aimed to drive one or two gas flow cut-off 12VD
More informationSENSORS. S8 Series HIGHLIGHTS APPLICATIONS. Phone: Fax: Web: -
The sensor is designed for frequent washdowns with a corrosion-resistant AISI316L stainless steel case IP69K rated, compliant to test environments like indicated by Diversey and Ecolab. However, all models
More informationCommunications None RS-232C RS-422* RS-485* BCD Transmission output*/** (4 to 20 ma) E5AX- E5AX- L(M)A02 L(M)A03
Digital Controller A 96 x 96-mm (DIN) Digital Process Controller Optimum PID control with feed-forward control circuitry. High accuracy (+0.3% FS +1 digit max.). Replaceable Output Units. Models with communications
More informationInstallation & Operation Manual
Boiler Control 275 Installation & Operation Manual Multi-Staging D 275 01/12 Replaces:03/09 The Boiler Control 275 is designed to stage up to four condensing or non-condensing, modulating or on-off boilers
More informationUser s Manual YTA610 and YTA710 NEPSI Certification
User s Manual YTA60 and YTA70 NEPSI Certification [Option code: /NS, /NS5 and /NF] st Edition . INTRODUCTION Thank you for purchasing the YTA60 and YTA70 Temperature transmitters. This manual contains
More informationMX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA
MX1A and MX1B: Laser Displacement Detection MX1A and MX1B: Laser Displacement Detection Built-in math capabilities available (MX1B only) Digital display on amplifier; easy setting and monitoring (MX1B
More informationINSTALLATION/OPERATING INSTRUCTIONS SEQUENCING PANELS
R INSTALLATI/OPERATING INSTRUTIS SEQUENING PANELS SEQ-6, SEQ-6P and SEQ-12 Panels to Sequence up to 12 Individual Stages with Lead-Lag and Manual Override apabilities TENTS SEQ FUNTI HART... 2 DIP SWITH
More information