1 Dynamic Escape Routing system D.E.R. system Sicherheitstechnik GmbH

2 We take new paths INOTEC Sicherheitstechnik GmbH is a mediumsized company that develops innovative and customer-oriented solutions in the area of emergency and safety lighting. A dynamic team of flexible and competent employees ensures reliable support in all matters relating to products, planning and regulations. Modern, high-tech products set new standards around the world, such as emergency lighting systems with JOKER technology and the Dynamic Escape Routing system D.E.R. This catalogue contains the INOTEC Dynamic Escape Routing system D.E.R. and complementary products. Should you require additional functions or components, please do not hesitate to contact our regional technical sales staff directly. Contents Page System description - 5 Copyright: INOTEC Sicherheitstechnik GmbH, Ense Reprinting and reproduction, even in excerpts, is permitted only with approval of the manufacturer. Subject to technical changes. The systems presented in the catalogue are not compatible with monitoring systems of the type INOTEC SVPC, SV central stations or multifunction controllers. Radio shielding acc. to DIN EN 5505 Application example 6-7 Circuit schematic 8-9 Luminaires overview 0 - System components and options - 5 Central monitoring 6-7

3 ollow us Are escape routes always escape routes? Emergency exit luminaires with fixed directional signs are used to mark escape routes and fulfil the task of enabling people to reach safe locations in the event of a power failure or a necessary evacuation. But what happens if fire and smoke are blocking the nearest escape route? What to do when heavy smoke emissions mean it is no longer possible to work out where you are? How do you find the escape route when the escape route sign is no longer visible? Do you have anything against a higher level of safety? INOTEC Sicherheitstechnik GmbH has taken on the problem of smoky escape routes with the aim of complementing fixed, unchangeable escape route signage with dynamic escape route guidance. A dynamic system has to fulfil two key tasks: on one hand, it must prevent anyone from escaping into an area that is already filled with smoke, and on the other, it must ensure that the people already in smoky areas can still find their way to the escape route. The solution is the Dynamic Escape Routing system (D.E.R.). Emergency exit luminaires with integrated LED matrix not only ensure static designation of escape routes, they can also be used for indicating an alternative escape route direction. Smoke-filled areas or escape routes can be visually blocked off in this way with a red, X-shaped pattern of LEDs. Because why should an escape route remain signposted when it is smoky and no longer usable? Luminaires for floor installation or wall installation near the floor are used for orientation in smoke-filled areas. In event of a fire, the running light function of these lights points the direction of the path to the emergency door and safety. The flashing function of the D.E.R. system can be useful for a building evacuation even when there is no fire.

4 We take new paths unctionality of the D.E.R. system The D.E.R. system communicates with the building's existing fire detection system. Potential-free contacts, activated by the fire alarm system, send a signal to the D.E.R. interface. The D.E.R. controller evaluates the defined information of the fire alarm system and activates the escape route direction patterns stored in the controller. This automatically activates the D.E.R. luminaires, which indicate the safe escape route with running lights, for example. The green LED arrows are used to indicate the direction. At the same time, the emergency doors that should no longer be used are visually blocked with red flashing LED X's. lashing lights mounted close to the floor near emergency doors additionally indicate the escape routes so that these remain identifiable even in the presence of smoke. Should the fire or smoke spread farther, the D.E.R. system can respond by activating other escape route plans and rearranging the luminaires accordingly. Even very small systems, starting with individual luminaires, can be implemented with limited functions by activating the luminaires directly via potential-free contacts of the fire alarm system. The high flexibility of the D.E.R. system results not only from its dynamic nature but also the option of connection to INOTEC emergency light systems as well as to any secured mains (AC/DC) with an appropriate voltage level. Regulations As a result of use of the innovative D.E.R. system in airports, hospitals, theatres, train stations etc., there has also been a response in terms of regulations. In January 00, the German ederation of Institutions for Statutory Accident Insurance and Prevention (HVBG) published the regulation BGR 6 "Visual Safety Guidance Systems (Including Safety Guidance Lighting)", which requires the use of nearto-floor safety guidance systems for buildings with increased risk under certain conditions. or example, this includes buildings with more than three storeys, building complexes with multiple interconnecting individual buildings, buildings with a large share of outside

5 ollow us personnel and buildings with a large share of people with reduced mobility (bed-ridden or physically disabled persons). EN 507 lists safety guidance systems that can increase the effectiveness when used along escape routes in addition to typical safety lighting luminaires. In the Technical Rule for Workplaces "Safety Lighting, Visual Safety Guidance Systems" ASR A./ from May 009, the Committee for Workplaces (ASTA) describes in detail the use of visual safety guidance systems for workplaces with reference to ASR A., which in turn regulates the cases in which a visual safety guidance system for escape routes is required. ire Safety Award The D.E.R. system was honoured by fire safety experts as a key development for increasing the safety of people by being awarded the Germany ire Safety Award 00. Apart from the current regulatory situation, additional applications have arisen in practice for dynamic escape route guidance systems. or example, such a system can be used to compensate for some structural fire protection measures. 5

6 D.E.R. system Application example The various D.E.R. components make it possible to realise flexible, dynamic escape route guidance that is adapted to the specific building. In event of smoke or fire, the people present will be guided safely out of the danger zone via the escape routes that are still open. 6

7 D.E.R. system Building with cinema, restaurant and car park D.E.R. in practical use D.E.R. luminaires can be useful for everyday orientation. The LED luminaires of series S000 are used for route designation or as accent lights in parking buildings or rooms intentionally kept dark, such as cinemas/theatres. 7

8 R T INOTEC GND RxD G/ +V InoLan TxD R R T INOTEC GND RxD T INOTEC GND RxD G/ G/ Betrieb Transmit Receive +V InoWeb TxD +V InoWeb TxD luchtweg. Bel. Betrieb Dienstag Muster 7.0 :00 Menue Netz Netz CP xa CP xa CP xa CP xa CP xa CP xa CP xa CP xa CP xa CP xa CP xa CP xa CP xa CP xa CP xa CP xa 6AT Ladeteil 0V/7,5A CP xa 6AT CP xa CP xa Ladeteil 0V/7,5A CP xa CP xa CP xa CP xa CP xa CP xa Betrieb Batt.-Betrieb Störung Lade- Störung Reset R T CP xa CP xa INOTEC CP xa Drucker Centronics Key-Board CP xa Betrieb Betrieb Betrieb Betrieb Betrieb Betrieb Störung Störung Störung Störung Störung Störung Test Test Test Test Test Test Ein CP xa Ein 0AT 0AT CP xa Batterie Batterie CP xa 5 AT 50 D.E.R. system Circuit schematic V signal via pot.-free contacts of the fire alarm control panel LSA 8 reset RTG RS VISU T R InoLan module VISU card Betrieb INOTEC luchtweg. Bel. Netz-Ausfall Betrieb Montag Muster Störung 7.0. :0 Menue Lade Störung Drucker Centronics Key-Board CPS 0 / 6 CPS 0 / 6 reset RTG RS W99 W99 W99 W99 W99 W99 T T T T T T R R R R R R D.E.R. controller with W99 and VISU cards Remote monitoring and floor plan visualisation with SVPCn software Secured network via generator, or battery system, e.g. INOTEC CPS V signal via pot.-free contacts of thefire alarm control panel LSA 8 V plug-in unit for CPS 0/6 SV,5A When using the V plug-in unit, CPUSB or CLS, remote monitoring is only possible via InoWeb-Control software in connection with an InoWeb module! reset RTG RS InoWeb module CPUSB V Remote monitoring by InoWeb-Control software Central battery system CPS 6 SV BUS substation for CPS 0/6 SV InoWeb module CLS V / SV 8

9 D.E.R Power Supply PSU 8 Am Buschgarten 7 D-5969 Ense U E : 0 V ~ 50/60 Hz U E : 8,5-60 V I : 0,8 A ON E U A : 8 V I A : A ϑ : C P/N : Am Buschgarten 7 D-5969 Ense U E : 0 V ~ 50/60 Hz U E : 8,5-60 V I : 0,8 A ON E U A : 8 V I A : A ϑ : C P/N : D.E.R Power Supply PSU SEV D.E.R. system Circuit schematic ire section L series 5 INOTEC Sicherheitstechnik GmbH INPUT OUTPUT N L + - INOTEC SEV module with power supply S series B series INOTEC Sicherheitstechnik GmbH INPUT OUTPUT N L + - SEV INOTEC SEV module with power supply S series ire section 5 S000 module S000 module S000 module ire section Third-party luminaire without monitoring Third-party luminaire without monitoring B series without monitoring L series (5000 range only) ire section L series (5000 range only) ire section L-Serie (nur 5000er) 8 V signal via pot.-free contacts of the ACP ire section 8 V signal via pot.-free contacts of the ACP 8 V signal via pot.-free contacts of the ACP 9

10 We develop for you Extremely durable stainless steel luminaire Green LED arrows for direction indication Running light function Control and automatic function monitoring via segment controller SEV or SEV/A S 000 BE Art. No Art. No lush floor installation Cable inlet from side Cable inlet from below 8 Housing material: Connection terminals: Stainless steel LEDs 8 V DC 6 ma Suitable for wires xx0.8 and pass-through wiring C Perm. temperature Protection category: IP 5 Protection class: III (safety extra-low voltage 8 V DC) S 000 TE Art. No Art. No lush carpet installation Cable inlet from side Cable inlet from below Stainless steel luminaires for wall installation in cavity wall box Green LED arrows for direction indication Running light function Control and automatic function monitoring via segment controller SEV or SEV/A S 000 WE Art. No lush wall installation ø90 ø58 ø7 Housing material: Connection terminals: Stainless steel LEDs 8 V DC 6 ma Suitable for wires xx0.8 and pass-through wiring C Perm. temperature Protection category: IP 0 Protection class: III (safety extra-low voltage 8 V DC) 6,5 0

11 Plan with us Tunnel or corridor luminaire Easily visible even from an extreme angle Green LED arrows for direction indication Running light function Control and automatic function monitoring via segment controller SEV or SEV/A S 7000 Art. No Wall surface installation Housing material: Stainless steel LEDs 8 V DC 6 ma Connection terminals:.5 mm² for pass-through wiring Perm. temperature C Protection category: IP 5 Protection class: III (safety extra-low voltage 8 V DC) Stainless steel luminaire Green LED arrow matrix for direction indication Running light function Control and automatic function monitoring via segment controller SEV or SEV/A Housing material: Stainless steel LEDs 8 V DC 00 ma Connection terminals:.5 mm² for pass-through wiring Perm. temperature C Protection category: IP 5 Protection class: III (safety extra-low voltage 8 V DC) S 000 Art. No Wall surface installation

12 We develop for you Tunnel luminaire Green LED arrow matrix for direction indication Integrated safety luminaire 0W LLp (optional LEDs) Control and automatic function monitoring via D.E.R. controller Electronics with output for a flashing luminaire of the B series L 00 WE Art. No L lush wall installation Housing material: Stainless steel VA powder-coated LEDs, 0W LLp (optional LEDs) 0V ±0% AC / 0V ±0% DC 9 ma SMains:. VA Connection terminals:.5 mm² for pass-through wiring Perm. temperature C Protection category: IP 65 Protection class: I 00 Colours Art. No. Colour code Silver-grey... L0 Special colours... L99 Append the colour code to art. no.: e.g LXX Channel luminaire Modular design reely selectable content: - LED arrow matrix for direction indication - Escape symbol backlit with LEDs - Green Xenon flashing lamp Control and automatic function monitoring via D.E.R. controller Adjustable length, e.g. to door width Electronics with output for a flashing luminaire of the B series L 000 Art. No V 7 je nach Ausführung 75 Wall surface installation Housing material: SMains: Connection terminals: Perm. temperature Protection category: Protection class: Viewing distance: Aluminium LEDs 0V ±0% AC / 0V ±0% DC 75 ma (minimum value depending on design).6 VA (minimum value depending on design).5 mm² for pass-through wiring C IP0 I 0 m Colours Art. No. Colour code Special colours... L99 Append the colour code to art. no.: e.g LXX Special pictograms upon request Please use the corresponding table at www. inotec-licht.de for specifying the luminaire content.

13 Plan with us LED arrow matrix for direction indication Control and automatic function monitoring via D.E.R. controller Electronics with output for a flashing luminaire of the B series L 6000 IP5 Art. No L0 6,5 Wall surface installation Housing material: Sheet steel powder-coated LEDs 0V +/- 0% AC; 0V +/- 0% DC 9 ma SMains: 9. VA Connection terminals:.5 mm² for pass-through wiring Perm. temperature C Protection category: IP 5 Protection class: I 95 Colours Art. No. Colour code Silver-grey... L0 Special colours... L99 Append the colour code to art. no.: e.g LXX LED arrow matrix for direction indication Escape symbol backlit with LEDs Control and automatic function monitoring via D.E.R. controller Electronics with output for a flashing luminaire of the B series L 6000L IP5 Art. No L0 59 6,5 Wall surface installation Housing material: Sheet steel powder-coated LEDs 0V +/- 0% AC; 0V +/- 0% DC 75 ma SMains:.6 VA Connection terminals:.5 mm² for pass-through wiring Perm. temperature C Protection category: IP 5 Protection class: I Viewing distance: 0 m 95 Colours Art. No. Colour code Silver-grey... L0 Special colours... L99 Append the colour code to art. no.: e.g LXX Special pictograms upon request

14 We develop for you Single-sided luminaire with LED arrow matrix for direction indication Escape symbol backlit with LEDs Control and automatic function monitoring via D.E.R. controller Electronics with output for a flashing luminaire of the B series L 600 Art. No L0 8 5 Wall installation 8 Housing material: SMains: Connection terminals: Perm. temperature Protection category: Protection class: Viewing distance: Sheet steel powder-coated LEDs 0V ±0% AC / 0V ±0% DC 75 ma.6 VA.5 mm² for pass-through wiring C IP 0 (IP 5, depending on design) I 0 m L 600 D Art. No L Ceiling installation Colours Art. No. Colour code Silver-grey... L0 Special colours... L99 Append the colour code to art. no.: e.g LXX L 600 P Art. No L0 Suspended installation 8 00 L 600 IP5 Art. No L0 Wall installation 6,5 ca. 85 Special pictograms upon request

15 Plan with us Double-sided luminaire with LED arrow matrix for direction indication Escape symbol backlit with LEDs Control and automatic function monitoring via D.E.R. controller Electronics with output for a flashing luminaire of the B series L 600 D Art. No L Ceiling installation Housing material: SMains: Connection terminals: Perm. temperature Protection category: Protection class: Viewing distance: Sheet steel powder-coated LEDs 0V ±0% AC / 0V ±0% DC ma 5 VA.5 mm² for pass-through wiring C IP 0 (IP 5, depending on design) I 0 m L 600 P Art. No L Suspended installation Colours Art. No. Colour code Silver-grey... L0 Special colours... L99 ca. 85 Append the colour code to art. no.: e.g LXX L 600 D IP5 Art. No L0 Ceiling installation 8 08 L 600 K IP5 Art. No L0 Chain installation 8 06 Special pictograms upon request 5

16 We develop for you Single-sided aluminium profile luminaire with LED arrow matrix for direction indication Escape symbol backlit with LEDs Control and automatic function monitoring via D.E.R. controller Electronics with output for a flashing luminaire of the B series L 786 Art. No Wall installation, 50, 80 Housing material: Aluminium LEDs 0V ±0% AC / 0V ±0% DC 75 ma SMains:.6 VA Connection terminals:.5 mm² for pass-through wiring Perm. temperature C Protection category: IP 0 Protection class: I Viewing distance: 0 m SNP 786 D Art. No Ceiling installation L 786 P Art. No Suspended installation Special pictograms upon request 6

17 Plan with us Double-sided aluminium profile luminaire with LED arrow matrix for direction indication Escape symbol backlit with LEDs Control and automatic function monitoring via D.E.R. controller Electronics with output a flashing luminaire of the B series L 786 D Art. No Ceiling installation 80 Housing material: Aluminium LEDs 0V ±0% AC / 0V ±0% DC 75 ma SMains:.6 VA Connection terminals:.5 mm² for pass-through wiring Perm. temperature C Protection category: IP 0 Protection class: I Viewing distance: 0 m L 786 P Art. No Suspended installation Special pictograms upon request 7

18 We develop for you Single-sided luminaire in modular design ( module) reely selectable content Symbols or templates backlit with LEDs Control and automatic function monitoring via D.E.R. controller or central battery system CPS 0/6 SV with V plug-in unit or V substation ( V version) Monitoring also possible with emergency lighting system CLS SV ( V version). Three additional control inputs for external control commands Energy supply generally possible via V or 8 V outside network. L 50 Art. No V L Wall installation V Can be equipped with: - Escape symbol as pictogram (LEDs white) - Directional arrow as pictogram (LEDs white) - Directional arrow as template (LEDs white or green) - Blocked symbol as template (LEDs red) Housing material: Sheet steel powder-coated LEDs V +/- 0% ( V version) I Bat Emerg. ( V version): 6 ma (white+green LEDs) or 6 ma (red LEDs) Connection terminals:.5 mm² for pass-through wiring Perm. temperature C Protection category: IP 0 Protection class: III ( V version) Viewing distance: 0 m L 50 WE Art. No V L lush wall installation V Colours Art. No. Colour code White textured... L0 Slate grey... L6 Special colours... L99 Append the colour code to art. no: e.g LXX Special pictograms upon request Please use the corresponding table at www. inotec-licht.de for specifying the luminaire content. 8

19 Plan with us Single-sided luminaire in modular design ( modules) reely selectable content Symbols or templates backlit with LEDs Control and automatic function monitoring via D.E.R. controller or central battery system CPS 0/6 SV with V plug-in unit or V substation (only V version) Monitoring also possible with emergency lighting system CLS SV ( V version) and central battery system CPS 0/8/6 (0 V version) Three additional control inputs for external control commands Energy supply generally possible via V, 8 V or 0 V outside network. L 50 Art. No V L6 Art. No V L Wall installation V 0 V Can be equipped with: - Escape symbol as pictogram (LEDs white) - Directional arrow as pictogram (LEDs white) - Directional arrow as template (LEDs white or green) - Blocked symbol as template (LEDs red) Housing material: Sheet steel powder-coated LEDs V +/- 0% ( V version) 0V +/- 0% AC; 0V +/- 0% DC (0 V version) I Bat Emerg. ( V version): Per module 6 ma (white+green LEDs) or 6 ma (red LEDs) I Bat Emerg. (0 V version): Per module 9 ma (white+green LEDs) or 8 ma (red LEDs) SMains (0 V version): Per module VA (white+green LEDs) or VA (red LEDs) Connection terminals:.5 mm² for pass-through wiring Perm. temperature C Protection category: IP 0 Protection class: III ( V version) or I (0 V version) Viewing distance: 0 m L 50 WE Art. No V L0 Art. No V L lush wall installation V 0 V Colours Art. No. Colour code White textured... L0 Slate grey... L6 Special colours... L99 Append the colour code to art. no: e.g LXX Special pictograms upon request Please use the corresponding table at www. inotec-licht.de for specifying luminaire content. 9

20 We develop for you Single-sided luminaire in modular design (5 modules) reely selectable content Symbols or templates backlit with LED Control and automatic function monitoring via D.E.R. controller or central battery system CPS 0/6 SV with V plug-in unit or V substation ( V version) Monitoring also possible with emergency lighting system CLS SV (only V version) and central battery system CPS 0/8/6 (0 V version) Three additional control inputs for external control commands Energy supply generally possible via V, 8 V or 0 V outside network. L 505 Art. No V L0 Art. No V L Wall installation V 0 V Can be equipped with: - Escape symbol as pictogram (LEDs white) - Directional arrow as pictogram (LEDs white) - Directional arrow as template (LEDs white or green) - Blocked symbol as template (LEDs red) Housing material: Sheet steel powder-coated LEDs V +/- 0% ( V version) 0V +/- 0% AC; 0V +/- 0% DC (0 V version) I Bat Emerg. ( V version): Per module 6 ma (white+green LEDs) or 6 ma (red LEDs) I Bat Emerg. (0 V version): Per module 9 ma (white+green LEDs) or 8 ma (red LEDs) SMains (0 V version): Per module VA (white+green LEDs) or VA (red LEDs) Connection terminals:.5 mm² for pass-through wiring Perm. temperature C Protection category: IP 0 Protection class: III ( V version) or I (0 V version) Viewing distance: 0 m L 505 WE Art. No V L6 Art. No V L lush wall installation V 0 V Colours Art. No. Colour code White textured... L0 Slate grey... L6 Special colours... L99 Append the colour code to art. no: e.g LXX Special pictograms upon request Please use the corresponding table at www. inotec-licht.de for specifying luminaire content. 0

21 Plan with us Plastic flashing luminaire (polystyrene) Xenon flashing lamp Control via luminaires of the L series or via S0 module (S0 module only in combination with D.E.R. controller) Housing material: Green plastic cover (polycarbonate) Xenon flashing lamp V DC 7 ma Connection terminals: Up to.5 mm² Perm. temperature C Protection category: IP 67 Protection class: II B 5000 V Art. No ø77 5 Wall / ceiling installation Supply modules for connection to - D.E.R. luminaires of the L series (ET 9/) 5 ø75 - Central battery system CPS 0 (J-ET 9/) - D.E.R. controller and secured network 0 V (S 0) in module housing incl. connection terminal adapter lashing luminaire for wall installation in cavity wall box Green plastic disc Control via luminaires of the L series or via S000 module (S000 module only in combination with D.E.R. controller) Housing material: Stainless steel Xenon flashing lamp 0V ±0% AC / 0V ±0% DC 0 ma SMains: 7. VA Connection terminals: Up to.5 mm² Perm. temperature C Protection category: IP 0 Protection class: I B 5000 WE Art. No ø90 ø58 ø7 50 6,5 lush wall installation Xenon flashing luminaire Green plastic disc Control via luminaires of the L series or via S000 module (S000 module only in combination with D.E.R. controller) B 5005 Art. No L0 00 Wall installation Housing material: Sheet steel powder-coated Xenon flashing lamp 0V ±0% AC / 0V ±0% DC 0 ma SMains: 7. VA Connection terminals: Up to.5 mm² Perm. temperature C Protection category: IP 0 Protection class: I Colours Art. No. Colour code White textured... L0 Special colours... L99 Append the colour code to art. no: e.g LXX

22 We develop for you Regulated power supply With mains and overload display via LED (only PSU and 8-) Output electrically isolated acc. to EN (safety low voltage) Suitable for flush mounting on DIN profile rails Various designs with various output current levels or supplying the segment controller SEV with luminaires of the S series (8 V) and the interface LSA8 ( V) PSU Art. No Supply device (PSU and 8-) Housing material: Thermoplastic 0 V +/- 5% AC, 8-60V DC Output voltage: V (PSU ) or 8 V (PSU 8-) Output current:.5 A (PSU ) and A (PSU 8-) Overload capability: Sustained short-circuit-proof Perm. temperature -0 C C Protection category: IP0 (terminal) Protection class: I PSU 8- Art. No Supply device (PSU 8-.6 and 8-5) PSU 8-.6 Art. No. 6 0 Supply device Housing material: Aluminium 0 V AC 0-70 V DC Output voltage: 8 V DC Output current:.6 A (PSU 8-.6) and 5 A (PSU 8-5) Overload capability: Sustained short-circuit-proof Perm. temperature -0 C C Protection category: IP0 (terminal) Protection class: I 5, 00 55,5 PSU 8-5 Art. No. 6 0 Supply device 5, 00 5,5

23 Plan with us Segment controller for programming, control, management and testing of up to 96 S luminaires. Connection to D.E.R. controller via -wire bus line. Two-line display, buttons for programming and testing, red LED for fault indication. 8 V input voltage via regulated power supply of type PSU 8. SEV Art. No Housing material: Plastic DIN rail housing 8 V Output voltage: 8 V Address SEV 0-99 Luminaires 0-96 Wire connection: Double-use terminal.5 mm² Perm. temperature C Power consumption: Max..7 Protection category: IP 0 Dimensions: 90 mm x 70 mm x 58 mm (HxWxD) Independent segment controller for programming, control, management and testing of up to 96 S luminaires. Two-line display, buttons for programming and testing, red LED for fault indication. Wide voltage input ( to 8 V DC) for pattern creation. Two patterns can be programmed. Automatic function test. Potential-free fault signalling contacts (NO-contacts). 8 V input voltage via regulated power supply of type PSU 8. SEV/A Art. No Housing material: Plastic DIN rail housing 8 V Output voltage: 8 V Address SEV 0-99 Luminaires 0-96 Wire connection: Double-use terminal.5 mm² Perm. temperature C Power consumption: Max..7 Protection category: IP 0 Dimensions: 90 mm x 70 mm x 58 mm (HxWxD)

24 We develop for you V circuit plug-in unit or substation CPUSB with circuits for central battery system CPS 0/6 in combination with TT convenient control unit for supply, control and monitoring of V D.E.R. luminaires (L 5000 series). Mixed operation within one circuit with V INOTEC LED system luminaires. - -pole protection per circuit - Individual luminaire control and monitoring - Max. 0 luminaires per circuit - Control and monitoring without data line - Luminaires can be individually programmed and addressed - output circuits in protection class III (SELV) at.5 A - switching inputs can be freely assigned to each luminaire CPUSB 0/6/-.5/V CP V x.5 A Art. No. 9 6 Art. No Interface for connection to D.E.R. controller (max. units per controller). Escape route patterns programmed in the D.E.R. controller can be activated via 8 switching inputs of the module. The input voltage of the LSA 8. channels may be from 5 to 0 V DC. The input voltage is connected to the inputs via potential-free contacts, such as from a fire alarm system. LSA 8. V Art. No Supply device unction-monitored control module for connection to an W99 card (BUS) and a secured power supply (e.g. CPS 0). Consumers of up to 0 W can be switched via the module. Housing material: Output voltage: Perm. temperature Protection class: Wire connection: Monitoring, supply and control module for to 6 power LEDs for connection to the W99 card of a D.E.R. controller (BUS) and a secured power supply (e.g. CPS 0). lashing function, switching on and off of the connected LEDs -pole socket board for connection of the LEDs Also suitable for supplying and activating the flashing luminaire B 5000 V. Housing material: Output voltage: Perm. temperature Protection class: Wire connection: Polycarbonate UL V0 0V 50/60 Hz, 0V +/- 0% DC 0V 50/60 Hz, 0V +/- 0% DC C I.5 mm² single core or.5 mm² braided with cable end sleeve Polycarbonate UL V0 0V 50/60 Hz, 0V +/- 0% DC V DC C I.5 mm² single core or.5 mm² braided with cable end sleeve S 000 Art. No S 0 Art. No

25 Plan with us ully automatic microprocessor-controlled testing device for monitoring of max. 58 addresses in connection with INOTEC luminaires of the L series, S000 or S0 modules and segment controllers SEV. Suitable for inclusion of max. 6 plug-in cards (W99 and Visu). Serial data bus via -wire, unshielded data line, e.g. YR x 0.8 mm². reely programmable, automatic function test of all connected luminaires, modules and segment controllers. Error messages: - Lamp defective - Transmission error - Device error The following standard functions are included: - All test results of the last two years are automatically saved and can be loaded at any time (up to 000 events) - Printer interface for maintaining the required log book according to standards - Potential-free collective fault contact Options: The controller can also be expanded with expansion modules (max. 6 plug-in units each) (max. 6 plug-in units per controller). D.E.R. controller Art. No Expansion module Art. No D.E.R. controller 0 Housing material: Mains voltage: Protection category: Protection class: Polycarbonate 0 V AC ± 0 %, 50/60 Hz 0 V DC ± 0 % II IP0 EMC protection in acc. with EN W 99 module Art. No Accessories W 99 module Plug-in unit for D.E.R. controller for control, management and testing of max. 99 bus devices such as luminaires of the L series, segment controllers SEV and S 000 or S 0 modules. ViSU module Plug-in unit for D.E.R. controller as interface for data transmission to a PC via SVPCn software in connection with an InoLan module for visualisation of a D.E.R. system. ViSU module InoLan Art. No Art. No InoLan module Converter between Ethernet and serial INOTEC-RTG data bus or RS. 5

26 Central monitoring and data backup Centralised, PC-controlled monitoring is recommended in order to maintain an overview of even complex installations. The INOTEC SVPCn software supports you in commissioning and programming as well as in the testing and logging required during daily operation. Whether the INOTEC-specific RTG-BUS, an existing network or the Internet is used for connection to the PC depends on the specific project requirements. SVPCn Software Logbook Panel : C0 ================================================= I : I Segment failure : Card is installed ailure --> Card : Sum-failure ailure --> Card : Data communication failure I : I Segment failure : Card is installed ailure --> Card : Sum-failure ailure --> Card : Data communication failure I : I Segment failure unctionality: Monitoring of up to D.E.R. or NEA controllers Individual signalling of up to 7,50 addresses for D.E.R. systems Automatic function test Zoomable floor plan display (DX files) Test log can be accessed and printed from the control components Each individual luminaire can be programmed via the interface Transmission via the existing Ethernet Programming can be secured against unauthorised access with a password System requirements: Operating system: Win98/000/XP/Vista/ 7 Business/Vista Enterprise Monitor: VGA (60x80), 56 colours or more Interface: INOLAN module via RJ5 port 6

27 : :0 Betrieb Betrieb Betrieb Betrieb Betrieb Betrieb Störung Störung Störung Störung Störung Störung Test Test Test Test Test Test Betrieb Betrieb Betrieb Betrieb Betrieb Betrieb Störung Störung Störung Störung Störung Störung Test Test Test Test Test Test D.E.R. system Central monitoring and data backup Detailed status information can be accessed for each luminaire. The exact location designation from the control component is also displayed in the interface. Every setting can be programmed on the control component and the luminaire from the PC. InoLan INOTEC Betrieb NE-SV-Überwachung Batt.- Betrieb Betrieb Störung Menue -> INOTEC Betrieb NE-SV-Überwachung Batt.- Betrieb Betrieb Störung Menue -> W99 W99 W99 W99 W99 W99 Ladestörung R T Drucker Cetronics Key-board T T T T T T R R R R R R Ethernet DER InoLan NE99 NE99 NE99 NE99 NE99 NE99 Ladestörung R T Drucker Cetronics Key-board T T T T T T R R R R R R NEA Red = failure By using DX files for representing the floor plan, the plan can be zoomed in and out. The luminaire status is highlighted in colour. Green = normal operation 7

28 /0 INOTEC Sicherheitstechnik GmbH Am Buschgarten 7 D Ense Tel / ax / info@inotec-licht.de 8 Sicherheitstechnik GmbH

Dynamic Escape Routing System. D.E.R.-System. Sicherheitstechnik GmbH

Dynamic Escape Routing System. D.E.R.-System. Sicherheitstechnik GmbH Dynamic Escape Routing System D.E.R.-System Sicherheitstechnik GmbH D.E.R.-System New routes to safety Vision and resulting products Since the start of our company we work to bring ideas and visions regarding

More information

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing AE-CU Adaptive Escape Routing for Emergency Lighting From static to adaptive escape routing We make what matters work.* * At Eaton, we believe that power is a fundamental part of just about everything

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Phone: 040 807-0 Fax: 040 807-259 Alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC display

More information

Remote alarm indicator and test combination MK2430

Remote alarm indicator and test combination MK2430 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 35305 Grünberg Tel.: 040 807-0 Fax: 040 807-259 Remote alarm indicator and test combination MK2430 Remote alarm indicator and test combination with LC

More information

LED Exit-luminaire. Akzent. Superior in function, light output, design life and appearance. Sicherheitstechnik GmbH

LED Exit-luminaire. Akzent. Superior in function, light output, design life and appearance. Sicherheitstechnik GmbH LED Exit-luminaire Akzent Superior in function, light output, design life and appearance Akzent A real highlight on interior design. Perfect safety and functionality in combination with a clear image and

More information

Parameterisable compact fault annunciator with permanent display

Parameterisable compact fault annunciator with permanent display Parameterisable compact fault annunciator with permanent display FSM 10 Drop-flap fault annunciator 31.08.2010 Permanent display even on power failure Compact module for 10 alarms Supply and alarm signal

More information

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10. 2 Device technology XS/S 1.1 2CDC 071 115 F0008 The Interface XS/S 1.1 integrates the Intrusion Alarm Panel L240 into the KNX intelligent installation system. It is connected to the XIB bus of the Intrusion

More information

CATALOGUE Controls/Networks STRACK LIFT AUTOMATION. MULTiBUS -Coupler

CATALOGUE Controls/Networks STRACK LIFT AUTOMATION. MULTiBUS -Coupler CATALOGUE Controls/Networks 2018.1 -Coupler 1.3 Controls/Networks 2018.1 -Coupler -Coupler -Coupler Controls/Networks 2018.1 1.3 Extend (third-party) lift controls with LIFTnet, a dynamic fire control

More information

Safer & quicker evacuation From Emergency Lighting Systems to Adaptive Evacuation Systems

Safer & quicker evacuation From Emergency Lighting Systems to Adaptive Evacuation Systems Safer & quicker evacuation From Emergency Lighting Systems to Adaptive Evacuation Systems Kai Sabla 12.07.2018 Large buildings, housing retail, leisure, hospitality, entertainment and transport facilities

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Bender Incorporated 700 Fox Chase, Coatesville PA 1930 Tel.: (800) 356-466 Fax: (610) 383-7100 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control function

More information

1.7. Insulation fault evaluators EDS460/490 EDS461/491

1.7. Insulation fault evaluators EDS460/490 EDS461/491 Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 06401 807-0 Fax: 06401 807-59 Insulation fault evaluators EDS460/490 EDS461/491 Insulation fault evaluators with display and control

More information

Universal fault annunciator for panel mounting

Universal fault annunciator for panel mounting Universal fault annunciator for panel mounting Communication over Ethernet USM - Universal-fault annunciator for panel mounting Low depth housing for panel mounting Versions with 8, 16, 32 or 48 inputs

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Wed : www.saenchotesei.com WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 920 - Wall, 19 Rack or Panel Mounting Units - 110/230V 50/60Hz AC operation - 250 Addressable

More information

Fire control panels FC726 FC726-XA

Fire control panels FC726 FC726-XA Fire control panels FC726 FC726-XA Modular, pre-confectioned, microprocessor-controlled fire control panel for up to max. 1512 device addresses Integrated, user-friendly operating unit Detection and automatic

More information

NEW RUSIC DYNAMIC - RSV RUHSTRAT STROMVERSORGUNGEN fills the gap. The all purpose safety lighting systems! Emergency lighting.

NEW RUSIC DYNAMIC - RSV RUHSTRAT STROMVERSORGUNGEN fills the gap. The all purpose safety lighting systems! Emergency lighting. RSV RUHSTRAT STROMVERSORGUNGEN fills the gap NEW Fire alarm system Emergency lighting Dynamic safety lighting system with RUSIC DYNAMIC - The all purpose safety lighting systems! RSV Ruhstrat Stromversorgungen

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with 8, 16, 24, 32, 40 and 48 signal inputs Status retention of inputs and sequence in case

More information

Panel Mounted Fault Annunciator Series

Panel Mounted Fault Annunciator Series Panel Mounted Fault Annunciator Series BSM / USM Panel-mounted fault annunciator Annunciators for panel mounting with,,,, 0 and signal inputs Storage of the last state of inputs and sequence in the case

More information

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel Synova Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches, punch cards, etc. unnecessary

More information

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances _D00108_00_D_XXEN/05.2015 ISOSCAN Insulation fault locator for DC IT systems with high system leakage capacitances

More information

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel Synova TM Commissioning in no time thanks to automatic address allocation Auto-addressing makes setting dip switches unnecessary Automatic

More information

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi 50 (P/N 10-071) is a state-of-the-art true intelligent digital peer-to-peer modular suppression control system.

More information

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems) ISOSCAN EDS460/490 EDS461/491 Insulation fault locators with control and display function for EDS systems (insulation fault location systems) EDS460-490_D00085_01_D_XXEN/01.2017 ISOSCAN EDS460/490 EDS461/491

More information

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax: Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 5 505 Grünberg Tel.: 00 807-0 Fax: 00 807-259 Insulation monitoring device for unearthed AC/DC systems (IT systems for the supply of operating theatre

More information

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing AE-CU Adaptive Escape Routing for Emergency Lighting From static to adaptive escape routing WorkSafe Protect your people and property Specify superior escape route management technology in complex buildings

More information

IQ8Control C Fire Alarm Panel

IQ8Control C Fire Alarm Panel IQ8Control C Fire Alarm Panel State-of-the-art processor technology Maximum cable length for esserbus: 3,500 m Graphics supported, high performance programming tool Innovative alarm signalling by means

More information

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION Fike s CyberCat 254 (P/N 10-066) is a state-of-the-art true intelligent digital peer-to-peer modular fire alarm control system.

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems LINETRAXX RCMA420 Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems RCMA420_D00059_01_D_XXEN/06.2016 LINETRAXX RCMA420 Residual current monitor for monitoring AC,

More information

Insulation fault evaluator EDS460-DG

Insulation fault evaluator EDS460-DG Insulation fault evaluator for localising insulation faults in DC IT systems with a number of branch circuits where high system leakage capacitances are involved Preliminary data sheet TDB108021en/09.2008

More information

Fire control panel detect 3004 plus and accessories

Fire control panel detect 3004 plus and accessories Fire control panel detect 3004 and accessories The modular fire alarm panel detect 3004 is the basic version of a broad product portfolio of the system detect 3000. Up to 20 fire control panels can be

More information

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION Fike s Cheetah Xi (P/N 10-068) is a state-of-the-art true intelligent digital peer-topeer modular suppression control system. It is ideal for

More information

Operating Manual RCM420

Operating Manual RCM420 Operating Manual RCM420 Residual current monitor for AC current monitoring in TN and TT systems Software version: D240 V1.2x TGH1410en/03.2012 Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Germany

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in

More information

Fire control panels FC360

Fire control panels FC360 Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses

More information

The Elevator Control System

The Elevator Control System www.liftcore.com v1.0-2017 The Elevator Control System LiFTCORE is part of an international group of companies with locations in Germany, China and USA. Partner companies in Europe, Southeast Asia and

More information

HRX Technical Manual. Version 1.2

HRX Technical Manual. Version 1.2 HRX 5000 Technical Manual Version 1.2 Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire

More information

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL PRODUCT Specification FEATURES Designed To Meet The Requirements Of EN54 Expandable From 1 To 5 Loops As Standard A Variety Of Networking Options

More information

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460) Operating Manual TS400 Test Station for Microtector II Series (G450/G460) GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)2 31 / 5 64 00 0 FAX +49 / (0)2 31 /

More information

Multi-Gas-Controller MGC2

Multi-Gas-Controller MGC2 Page 1 Aug. 2018 Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology for continuous monitoring of the ambient air to detect toxic and combustible gases, refrigerants

More information

Memcom Emergency Telephone

Memcom Emergency Telephone Memcom Emergency Telephone Installation Guide Ref No. 450 900 (GB) Version 2 + + Simple wiring for quick installation + + Integrated LCD display shows you what you have programmed + + All code based programming

More information

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1 Operation Manual Fighter ProVision Software Version: 0.0 Revision: 1 TABLE OF CONTENTS 1. Introduction 5 2. Software Installation 5 3. PC Users 6 3.1 Introduction 6 3.2 Default Code 6 3.3 Edit PC User

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel

More information

FC722 Fire control panel

FC722 Fire control panel FC722 Fire control panel Series FS720 (MPXS) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as

More information

Radio fire warning panel SRC 3000

Radio fire warning panel SRC 3000 Radio fire warning panel SRC 3000 6 zone radio fire warning panel Operating instructions Version 1.2 Art. 32487 detectomat GmbH Headquarter: Phone: +49 (0) 4102-2114-60 An der Strusbek 5 Fax: +49 (0) 4102-2114-670

More information

Product Data Sheet. Remote Terminals. Features:

Product Data Sheet. Remote Terminals. Features: Remote Terminals Product Data Sheet Features: Based around two core products, the Mx- 4010 Remote Display Terminal (RDT) and the fully functional Mx-4020 Remote Control Terminal (RCT). Both remote terminals

More information

Window facia fault annunciators

Window facia fault annunciators Window facia fault annunciators WAP Window Annunciator Panel 15.08.2017 Annunciators for panel mounting with 24 signal inputs Storage of the last state of inputs and sequence in the case of power failure

More information

FC723 Fire control panel

FC723 Fire control panel FC723 Fire control panel FS720 series (IP5) Cerberus PRO Modular, prefabricated, microprocessor-controlled fire control panel with integrated user-friendly operating unit for up to max. 756 addresses Processes

More information

Solution F2. Fire Alarm Control Panels one step ahead.

Solution F2. Fire Alarm Control Panels one step ahead. Solution F2 Fire Alarm Control Panels one step ahead. Sicherheitstechnik Sicherheitstechnik GmbH GmbH The Fire Alarm Control Panel Solution F2 Solution F2 in B2 enclosure (B01090-00) The Concept The Solution

More information

FC700A Fire detection control unit

FC700A Fire detection control unit FC700A Fire detection control unit Synova 4-16 Loop analogue addressable control panel 128 devices per loop (SynoLOOP) and up to 1000 devices per panel Up to 24 collective lines for Synova TM 600 serie

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

APC BC300 Series 40kW 208/450/480V User Guide

APC BC300 Series 40kW 208/450/480V User Guide APC BC300 Series 40kW 208/450/480V User Guide Copyright 2002 APC Denmark ApS This manual is subject to change without notice and does not represent a commitment on the part of the vendor Thank You Thank

More information

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X X testregistrierung Type Web server, also for mobile devices Zone modules Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems X-AIRCONTROL zone

More information

PolyGard 2-channel Gas Controller MGC-03

PolyGard 2-channel Gas Controller MGC-03 PolyGard 2-channel Gas Controller MGC-03 DESCRIPTION Gas measuring and monitoring controller based on state-ofthe-art micro-technology with integrated buzzer for continuous monitoring of the ambient air

More information

PRELIMINARY EDITION

PRELIMINARY EDITION 3 131 PRELIMINARY EDITION 14.01.2003 Synco 700 Heating Controllers Heating controller for medium-size and large buildings. The is used as a heating circuit or primary controller. The controller is supplied

More information

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual

RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C. Operating Manual Operating Manual RCMA423-DM RCMA423-DM1C RCMA423-DM2C RCMA423-DM3C Residual current monitor with one analogue output signal for monitoring AC-, DC- and pulsed DC currents in TN- and TT systems Software

More information

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage

LINETRAXX VME420. Multi-functional relay for overvoltage, undervoltage and frequency monitoring in AC/DC systems with external supply voltage LINETRAXX VME420 Multi-functional monitoring relay for undervoltage, overvoltage and frequency monitoring in AC/DC systems with separate supply voltage VME420_D00026_01_D_XXEN/06.2016 LINETRAXX VME420

More information

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual

Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual Syncro Matrix Analogue Addressable Fire Alarm Mimic Panel Product Manual Australia Issue 01 April 2012 Contents 1 Introduction 3 2 Safety 3 3 Installation 4 3.1 Mounting the Cabinet 4 4 Specifications

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

561-MB256 plus. Intruder alarm control panel. Performance features

561-MB256 plus. Intruder alarm control panel. Performance features 561-MB256 plus Intruder alarm control panel The intruder alarm control panel 561-MB256 plus is designed for use in private and commercial zones and is highly suitable for setting up medium to large-sized

More information

ACP10 & ACP50 Security Systems

ACP10 & ACP50 Security Systems ACP10 & ACP50 Security Systems System Configuration LCD Keypad LCD Keypad LED Keypad LED Keypad 4-wire Bus ACP10 & ACP50 AEX10* AEX10* AEX10* AEX10* * ACP50 Only Control Panels The ACP10 control panel

More information

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min

Heat on. Air heaters. Blowers. from 400 Watt to Watt. from 1,45 m 3 /min to 16,5 m 3 /min Heat on Air heaters from 400 Watt to 17 400 Watt Blowers from 1,45 m 3 /min to 16,5 m 3 /min BAK Thermoplastic Need-to-know Calculation of air heaters 1. Heat requirement calculation Formula: Q = m * c

More information

Product overview. Alarm indicator, operator and display panels

Product overview. Alarm indicator, operator and display panels Product overview Alarm indicator, operator and display panels 1 2 Innovative operating concepts for safe power supply in all medical locations Despite all technology that is necessary in medical locations

More information

with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4)

with internal sensor (channel 1) with an external sensor (channel 2) A-Editor software, Professional AK20 version (not for version AK4) Examples of use Example Creating an SMS-based alarm with confirmation A project file must first be created using the A-Editor software. This project file is then stored in the alarm modem. The alarm modem

More information

Bionics Instrument. Alarm Handling. Gas Alarm Systems

Bionics Instrument. Alarm Handling. Gas Alarm Systems Gas Alarm Systems Controllers and PLC based systems Alarm Handling Complete control at the right time and place Every gas detector consist of a gas sensor and a signal transmitter. In case of a gas leak,

More information

PR / MP I Laboratory / Medicine

PR / MP I Laboratory / Medicine Technology for Life Medical SYSTEMS Technology for Life PR / MP I Laboratory / Medicine / Pharmaceutical Refrigerators (with glass door) +5 C +4 C 292.9707.80 02/2013 BIOMEDICAL REFRIGERATION Innovative

More information

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly Operation Manual GMA200-MT Gas detection controller for mounting rail assembly GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, Germany TEL. +49 / (0)231 / 564 00 0 FAX +49 / (0)231

More information

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG A T L A S - SolarClimatic Test Cabinet SC 2000 MHG A T L A S - SolarClimatic Type Test chamber capacity SC 2000 MHG approx. 3400 l Radiation area approx. 1.36 m 2 TECHNICAL DATA Characteristic values for

More information

HRX3000. Technical Manual

HRX3000. Technical Manual HRX3000 Technical Manual Contents: Specification...2 Connectors...3 Power (J21)...3 RS-485 Network Connectors (J6 and J7)...4 RS-232 to PC (J8)...5 Printer and Fire Alarm Panel (J19)...6 TCP/IP...8 Modem

More information

SCR100 User Manual. Version:1.1 Date:Dec 2009

SCR100 User Manual. Version:1.1 Date:Dec 2009 SCR100 User Manual Version:1.1 Date:Dec 2009 Introduction: This document mainly introduces the installations and connections of SCR100 products, and the brief operations about attendance software. Important

More information

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40 Technical Description Laboratory Climate Test Chamber System Weiss Mat. No.:67592625 Type WKL 34/40 FACTS The test chambers types WTL/WKL with compact exterior dimensions were especially developed for

More information

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

Syncro AS. Analogue Addressable Fire Control Panel. User Manual Syncro AS Analogue Addressable Fire Control Panel User Manual Man-1100 Issue 02 Nov. 2008 Index Section Page 1. Introduction...3 2. Safety...3 3. Panel Controls...4 3.1 Access Level 1...4 3.2 Access Level

More information

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point Medium - Control - System Franke & Haqenest GmbH Borngasse 1a * 04600 Altenburg Tel: 03447-499 313-0 Fax: 03447-499 313-6 email: info@mcs-gaswarnanlagen.de MCS User Guide MCS GasController Microprocessor

More information

Networked Access Control Panel. Installation Guide

Networked Access Control Panel. Installation Guide XP2M Networked Access Control Panel V1.0X Installation Guide X P 2 M A C C E S S C O N T R O L S Y S T E M Installation Guide Document Ref: PLAN XP2M Installation Guide V4(G)2010 Access Control Services

More information

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE General Description This guide provides a summary for installing and configuring the Centaur TM Cube Slave Alarm Signalling Equipment

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET Control Systems Transmitters Sensors Accessories Wall, 19 Rack or Panel Mounting Units 110/230V 50/60Hz AC operation 250 Addressable devices as: Relays, 4-20 Inputs or Gas Detectors

More information

Dew point set DS 400

Dew point set DS 400 set DS 400 Dew point set DS 400 for stationary dew point monitoring of refrigeration or adsorption dryers. The touch screen graphic display enables an intuitive operation and shows the progress of the

More information

GEZE SAFETY TECHNOLOGY. GEZE SecuLogic EMERGENCY EXIT SYSTEMS SAFETY ON ESCAPE AND RESCUE ROUTES BEWEGUNG MIT SYSTEM

GEZE SAFETY TECHNOLOGY. GEZE SecuLogic EMERGENCY EXIT SYSTEMS SAFETY ON ESCAPE AND RESCUE ROUTES BEWEGUNG MIT SYSTEM GEZE SAFETY TECHNOLOGY GEZE SecuLogic EMERGENCY EXIT SYSTEMS SAFETY ON ESCAPE AND RESCUE ROUTES BEWEGUNG MIT SYSTEM Title and cover photo: GEZE GmbH GEZE SecuLogic RWS TABLE OF CONTENTS GEZE emergency

More information

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting Operation Manual GMA200-MW16 Gas detection controller for wall mounting GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 44143 DORTMUND, GERMANY TEL. +49 / (0)231 / 564 00 0 FAX +49 / (0)231 / 516 313

More information

Datasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment. Heat Meter Integrator

Datasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment.  Heat Meter Integrator Datasheet Heat Meter Integrator Technical Overview The range of Heat Meter Integrators uses the latest innovative technology to calculate heat usage from heating and cooling systems. They are for use with

More information

User manual. KNXgal. version

User manual. KNXgal. version User manual version 1.3 gal Management alarm control panels Galaxy from bus powered from bus Communication indication on and with Galaxy control panel DIN rail mount (1 modul) Adjustable address on with

More information

EMERGENCY LIGHTING SYSTEM

EMERGENCY LIGHTING SYSTEM EMERGENCY LIGHTING SYSTEM 1300 INCITE www.incitefire.com.au PRODUCT CATALOGUE EXIT-EMERGENCY LIGHTING AN EXTRA LOW VOLTAGE EXIT & EMERGENCY LIGHTING SYSTEM FIREscape is a revolutionary emergency lighting

More information

Operation Instruction. VARIODYN D1 Comprio HO.GB / AA. Technical changes reserved Honeywell International Inc.

Operation Instruction. VARIODYN D1 Comprio HO.GB / AA. Technical changes reserved Honeywell International Inc. Operation Instruction VARIODYN D1 Comprio 798666.HO.GB0 07.2013 / AA GB Technical changes reserved. 2013 Honeywell International Inc. Intended use This product may only be used for the applications outlined

More information

600 Range Dialer Installation Manual. Version 1.0

600 Range Dialer Installation Manual. Version 1.0 600 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

Contents. 30 References

Contents. 30 References LIMITLESS IP SYSTEM Contents 05 Applications 07 What can Botech offer me 09 Video IP Intercom Systems 11 Doorbell Panel 13 Monitor for Single-Family Home 18 Doorbell Panel Villa Type 19 Integrated Security

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no ) Product definition KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no 2343 00) Art. no 2343 00 Page 1 of 22 Product definition Table of contents 1 Product definition... 3 1.1 Product catalogue...

More information

Turbimax CUE21 / CUE22

Turbimax CUE21 / CUE22 Technical Information Turbimax CUE21 / CUE22 Turbidimeter for on-line measurement Application On-line continuous monitoring of clean water: Drinking water Treated process water Your benefits Versions with

More information

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) T M 1 isopv425 and AGH420 Ground Fault Detector for Ungrounded Solar Arrays < 100 kw And Isolation Tester Prior to Array Startup (Grounded and Ungrounded) Technical Bulletin NAE1012670 / 08.2013 isopv425

More information

Danfoss gas detection units

Danfoss gas detection units Data sheet Danfoss gas detection units Types GD Premium, Premium+, Premium Duplex, Premium Remote, Premium Flex and Premium Uptime The Premium line gas detection units are used for monitoring and warning

More information

Gas Controller Module GC-06

Gas Controller Module GC-06 Page 1 Oct. 2015/2 Measuring, warning and controlling module for toxic, combustible and refrigerant gases and vapours. The gas controller series GC-06 is designed in accordance with the standard EN 50545-1.

More information

Why Hart XL Aspirating Smoke Detection?

Why Hart XL Aspirating Smoke Detection? HART XL Why Hart XL Aspirating Smoke Detection? Earliest detection to enable business continuity Extra time is required for safe evacuation Unnecessary suppression release must be avoided Smoke is difficult

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

FC724 Fire control panel

FC724 Fire control panel FC724 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as

More information

FC722 Fire control panel

FC722 Fire control panel FC722 Fire control panel Series FS720 (IP4) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as

More information

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual Revision 6/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual Revision 4/01.17 Contents 1. Introduction... 6 2. Terminology... 6 3. Function... 8 4. Technical data... 8 4.1. Physical configuration...

More information

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0 E21.X.01.6C-05 Operating Manual EB2000 MC page 1 Operating manual EB2000 MC EASYBUS-display with MIN-/MAX-alarm for up to 9 sensor modules Version 3.0 Pursuant to EN 50 081-1 and EN 50 082-2 for unlimited

More information

Di-440 The Modular Analyser

Di-440 The Modular Analyser Di-440 The Modular Analyser Instrument Concept Single tool for a range of service, maintenance and inspection applications: Condition assessment tool highlights state of machinery today NOT for Predictive

More information

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS

DCA4. Digitally controlled Audio Matrix. Current Thinking. Product Specification March Document Number DDC DCA ACS DCA4 Digitally controlled Audio Matrix Product Specification March 2002 Current Thinking Document Number DDC DCA 7001 01 ACS Introduction Voice Alarm (VA) systems are the quickest way to evacuate the public

More information