NFPA Technical Committee on Cultural Resources NFPA 909 Pre-ROC Meeting Agenda

Size: px
Start display at page:

Download "NFPA Technical Committee on Cultural Resources NFPA 909 Pre-ROC Meeting Agenda"

Transcription

1 NFPA Technical Committee on Cultural Resources NFPA 909 Pre-ROC Meeting Agenda November 8-9, 2011 Hilton Oakland Airport Oakland, California 1. Call to order, 9:00 a.m., Tuesday, November 8, 2011 D. Freeland. 2. Self-introduction of members and guests Page Approval of the June 23-25, 2011 NFPA 909 ROP meeting minutes Page Chair s report D. Freeland. 5. Staff liaison s report G. Harrington. 6. Review schedule for future committee meetings D. Freeland. i) April 24-25, 2012 (NFPA 909 ROC) M. Kilby Smithsonian Institution, Washington, DC. ii) September (20-21 for conference/tours), 2012 (NFPA 914 Pre-ROP) L. Nassi Venice, Italy. iii) July/August 2013 (NFPA 914 ROP) TBD. iv) Fall/Winter 2013 (NFPA 914 Pre-ROC) TBD. 7. Review negatives and affirmative comments on NFPA 909 ROP ballot Page NFPA 909 Task Group report C. Greczek. 9. NFPA 914 Task Group report S. Peterson. 10. Guest Presentation on Water Mist Systems/Background on Submitted Proposals Allan Rhodes & Dan Rose, Marioff Page Protecting Our Heritage Task Group report C. Domnitch. 12. TASK GROUP BREAK OUT SESSION 13. Portable Fire Extinguisher Agent Task Group report M. Kilby/C. Greczek. 14. Committee History D. McDaniel. 15. Automatic sprinkler system issues R. Fleming. 16. E.U. activities update M. Coull. 17. Other business. 18. Adjournment. Page 1 of 41

2 Address List No Phone Cultural Resources 6/1/2011 Gregory E. Harrington Deborah L. Freeland Chair Arthur J. Gallagher & Company 505 North Brand Blvd., Suite 600 Glendale, CA I 1/1/1988 Michael Coull SE 11/2/2006 Secretary Heritage Fire and Safety Ltd. 4 Lochinch Road Cove Bay, Aberdeen, AB12 3SL Scotland, United Kingdom Clare Ray Allshouse City of Shoreline, Washington Planning & Development Services Midvale Avenue North Shoreline, WA E 3/21/2006 Nicholas Artim Fire-Safety Network Box 895 Middlebury, VT SE 1/1/1990 Eileen E. Brady Washington State University Owen Science & Engineering Library Pullman, WA U 11/2/2006 Steve Carter Orr Protection Systems, Inc Interchange Drive Louisville, KY Fire Suppression Systems Association Alternate: Daniel J. Hubert M 7/19/2002 John E. Chartier Rhode Island State Fire Marshal 118 Parade Street Providence, RI National Association of State Fire Marshals E 8/2/2010 Laura E. Doyle US General Services Administration 301 7th Street SW, Room 2080 Washington, DC Alternate: Joseph Dafin U 9/30/2004 Wilbur Faulk Pepperdine University Pacific Coast Highway Malibu, CA U 1/1/1989 Robert F. Fisher FM Global Country Club Blvd., Suite 300 North Olmsted, OH I 7/1/1995 Russell P. Fleming National Fire Sprinkler Association, Inc. 40 Jon Barrett Road Patterson, NY Alternate: Peter W. Thomas M 10/10/1998 Cindy Greczek Colonial Williamsburg Foundation PO Box 1776 Williamsburg, VA Alternate: Danny L. McDaniel U 10/4/2001 Michael Kilby Smithsonian Institution 600 Maryland Avenue SW, Suite 7106 MRC 514, PO Box Washington, DC U 7/22/1999 Wolfgang Kippes Schloss Schoenbrunn Kultur und Betriebsges, m.b.h A-1130 Vienna, Austria U 7/12/2001 Page 2 of 41 1

3 Address List No Phone Cultural Resources 6/1/2011 Gregory E. Harrington George A. Krabbe East Raintree Drive Scottsdale, AZ Halon Alternatives Research Corporation SE 10/1/1994 Fred M. Leber LRI Fire Protection Engineering Yonge Eglinton Center 2300 Yonge Street, Suite 2100 PO Box 2372 Toronto, ON M4P 1E4 Canada SE 10/28/2008 Nancy Lev-Alexander US Library of Congress Conservation Division, LMG Independence Avenue, SE Washington, DC Alternate: Susan M. Peckham U 7/29/2005 Donald C. Moeller The Fire Consultants, Inc Durant Court Walnut Creek, CA California State Historical Building Safety Board E 7/26/2007 Wayne D. Moore Hughes Associates, Inc. 117 Metro Center Boulevard, Suite 1002 Warwick, RI Alternate: Cheryl L. Domnitch SE 1/1/1992 Kevin D. Morin Code Consultants, Inc. 215 West 40th Street, Floor 15 New York, NY Alternate: Michael D. Kirn SE 3/4/2009 Thomas F. Norton Norel Service Company, Inc. 37 Buckmaster Drive Concord, MA Automatic Fire Alarm Association, Inc. Alternate: Shane M. Clary M 1/1/1988 Sheila Palmer Chubb & Son Insurance Company 55 Water Street New York, NY Alternate: Richard P. Luongo I 1/15/2004 Steven M. Peterson US Department of the Interior National Park Service Alaska Support Office 240 West 5th Avenue, Room 114 Anchorage, AK Alternate: Todd J. Neitzel E 1/17/1997 Milosh T. Puchovsky Worcester Polytechnic Institute Department of Fire Protection Engineering 100 Institute Road Worcester, MA SE 10/27/2009 Martin H. Reiss The RJA Group, Inc Worcester Road, Suite 501 Framingham, MA SE 1/17/1997 Steven Rocklin New York State Department of State Division of Code Enforcement 1 Commerce Plaza 99 Washington Avenue Albany, NY E 10/4/2001 Page 3 of 41 2

4 Address List No Phone Cultural Resources 6/1/2011 Gregory E. Harrington John M. Watts, Jr. Fire Safety Institute PO Box 674 Middlebury, VT Alternate: Marilyn E. Kaplan SE 1/1/1977 Robert D. Wilson National Gallery of Art 6th Street & Constitution Ave., NW Washington, DC U 1/10/2002 Shane M. Clary Alternate Bay Alarm Company 60 Berry Drive Pacheco, CA Automatic Fire Alarm Association, Inc. : Thomas F. Norton M 11/2/2006 Joseph Dafin Alternate US General Services Administration 301 7th Street SW, Room 2080 Washington, DC : Laura E. Doyle U 8/5/2009 Cheryl L. Domnitch Alternate Hughes Associates, Inc San Ramon Valley Blvd., Suite 209 San Ramon, CA : Wayne D. Moore SE 10/27/2009 Daniel J. Hubert Alternate Janus Fire Systems 1102 Rupcich Drive, Millennium Park Crown Point, IN Fire Suppression Systems Association : Steve Carter M 3/15/2007 Marilyn E. Kaplan Alternate Preservation Architecture 43 Marion Avenue Albany, NY : John M. Watts, Jr. SE 1/14/2005 Michael D. Kirn Alternate Code Consultants, Inc Woodland Parkway, Suite 300 St. Louis, MO : Kevin D. Morin SE 10/20/2010 Richard P. Luongo Alternate Chubb & Son Insurance Company 202 Hall s Mill Road Whitehouse Station, NJ : Sheila Palmer I 7/26/2007 Danny L. McDaniel Alternate Colonial Williamsburg Foundation PO Box 1776 Williamsburg, VA : Cindy Greczek U 1/1/1980 Todd J. Neitzel Alternate US Department of the Interior National Park Service West Alameda Parkway Lakewood, CO : Steven M. Peterson E 10/20/2010 Susan M. Peckham Alternate US Library of Congress 1600 East Capitol Street, NE Washington, DC : Nancy Lev-Alexander U 3/4/2009 Page 4 of 41 3

5 Address List No Phone Cultural Resources 6/1/2011 Gregory E. Harrington Peter W. Thomas Alternate Tyco Fire Suppression & Building Products 1467 Elmwood Avenue Cranston, RI National Fire Sprinkler Association : Russell P. Fleming M 4/17/1998 Stewart Kidd Nonvoting Member Loss Prevention Consultancy, Ltd. 26 Broadway, Wilburton Ely, Cambridgeshire, CB6 3RT United Kingdom SE 4/1/1993 Stefano Marsella Nonvoting Member Via Orti Gianicolensi, 4 Rome, Italy SE 10/6/2000 Luca Nassi Nonvoting Member Italian National Fire Department Comando P.le VV.F. di Siena V.le Cavour 163 Siena, Italy E 10/27/2005 Stephen E. Bush Member Emeritus 1850 Kershaw Lane Winchester, VA SE 1/1/1974 William Jackson Member Emeritus 55 Albany Drive Lanark, ML11 9AF Scotland SE 1/1/1992 Charles E. Zimmerman Member Emeritus 8058 Carlton Street Norfolk, VA SE 1/1/1985 Gregory E. Harrington Staff Liaison National Fire Protection Association 1 Batterymarch Park Quincy, MA /29/2007 Page 5 of 41 4

6 MEETING MINUTES NFPA TECHNICAL COMMITTEE ON CULTURAL RESOURCES JUNE 23 25, 2011 Schloss Schönbrunn Vienna, Austria MEMBERS PRESENT Deborah Freeland, Chair Michael Coull, Secretary Ray Allshouse, Nicholas Artim, Laura Doyle, Russell Fleming, Cindy Greczek, Wolfgang Kippes, Fred Leber, Don Moeller, Wayne Moore, Kevin Morin, Thomas Norton, Sheila Palmer, Steven Peterson, Milosh Puchovsky, Shane Clary, Alternate Danny McDaniel, Alternate Luca Nassi (Nonvoting) ORGANISATION Arthur J Gallagher & Company Heritage Fire and Safety Ltd. City of Shoreline, Washington Fire-Safety Network US General Services Administration National Fire Sprinkler Association, Inc. Colonial Williamsburg Foundation Schloss Schönbrunn LRI Fire Protection Engineering The Fire Consultants, Inc. Rep. California State Historical Building Safety Board Hughes Associates, Inc. Code Consultants, Inc. Norel Service Company, Inc. Rep. Automatic Fire Alarm Association, Inc. Chubb & Son Insurance Company US Department of the Interior Worcester Polytechnic Institute Bay Alarm Company Rep. Automatic Fire Alarm Association, Inc. Colonial Williamsburg Foundation Italian National Fire Department William Jackson, Member Emeritus Gregory Harrington, Staff Liaison National Fire Protection Association GUESTS Gris Mateja Frank Peter Wolfgang Bachler Slovenian FPA Brandschutz Consulting and Engineering Bachler and Partners 1 Page 6 of 41

7 MEMBERS NOT PRESENT Eileen Brady, Steve Carter, John Chartier, Wilbur Faulk, Robert Fisher, Michael Kilby, George Krabbe, Nancy Lev-Alexander, Martin Reiss, Steven Rocklin, John Watts, Robert Wilson, Joseph Dafin (Alt to L. Doyle) Cheryl Domnitch, (Alt. to W. Moore) Daniel Hubert (Alt. to S. Carter) Marilyn Kaplan, (Alt to J. Watts) Michael Kirn (Alt. to K. Morin) Richard Luongo, (Alt. to S. Palmer) Todd Neitzel (Alt to S. Peterson) Susan Peckham (Alt. to N. Lev-Alexander) Peter Thomas (Alt. to R. Fleming) Stewart Kidd (Nonvoting) Stefano Marsella (Nonvoting) Stephen Bush (Member Emeritus) Charles Zimmerman (Member Emeritus) Washington State University Orr Protection Systems, Inc. Rep. Fire Suppression Systems Association Rhode Island State Fire Marshal Rep. National Association of State Fire Marshals Pepperdine University FM Global Smithsonian Institution Rep. Halon Alternatives Research Corporation US Library of Congress The RJA Group, Inc. New York State Department of State Fire Safety Institute National Gallery of Art US General Services Administration Hughes Associates Janus Fire Systems Rep. Fire Suppression Systems Association Preservation Architecture Code Consultants, Inc Chubb & Son Insurance Company US Department of the Interior US Library of Congress Tyco Fire Suppression & Building Products Rep. National Fire Sprinkler Association Loss Prevention Consultancy, Ltd. Italian National Fire Department 1. CALL TO ORDER/WELCOME Debbie Freeland called the meeting to order at She welcomed the committee to Vienna and thanked Wolfgang Kippes for his work organising the meeting and conference venue. Debbie presented Wolfgang with a gift in recognition of the support he has provided to the committee. 2. SELF INTRODUCTIONS OF MEMBERS AND GENERAL ANNOUNCEMENTS Debbie thanked Mike Coull for assuming the role of committee secretary. 2 Page 7 of 41

8 The committee congratulated Bill Jackson on his appointment to the position of Member Emeritus on the committee, after many years serving as the secretary. Bill was further congratulated on receiving the Special Achievement Award from the NFPA, which was presented to him during the annual NFPA Conference & Expo in Boston. Cards were sent from the committee to Steve Rocklin, who is recovering from hip replacement surgery, and George Krabbe, who has undergone open-heart surgery. 3. APPROVAL OF MEETING MINUTES OF OCTOBER 2010 IN HYDE PARK. The minutes were approved as presented. 4. CHAIR S REPORT Membership Debbie Freeland welcomed new members; Todd Neitzel, National Park Service, who has been appointed alternate to Steve Peterson. Michael Kirn, Code Consultants, Inc., who has been appointed alternate to Kevin Morin. Mickey Reiss, The RJA Group, Inc., moves from voting alternate to principal following Bob Barnes s change of employment. Michael Kilby had previously been moved to principal for the Smithsonian in anticipation of Andy Wilson s retirement. Andy has now retired and is looking to return to the committee in another capacity. The committee is full with a good hold list. Bob Barnes has reapplied to the committee, but he is now employed by Hughes Associates, which already has full representation. Debbie Freeland thanked those members of task groups for the work they have done since our last meeting. She acknowledged that there has been a tremendous amount of activity, based on the s she has been copied on, and looks forward to hearing the task group reports. 5. STAFF LIAISON S REPORT Greg Harrington stated that the e-committee pages of the NFPA website have now been shut down and all committee information is now available through the main NFPA website. Greg gave an overview of navigating the pages on the site and advised the quickest link to the committee s pages is through or Greg Harrington updated the committee on the new NFPA standards development process. One area that will change is that the existing proposal stage will be renamed the public input stage. A significant difference from the existing process is how the committee responds to public input. Under the current regulations, the committee must 3 Page 8 of 41

9 review and vote on each public proposal. The committee actions are then balloted and published. Under the new process, the committee will focus at its meeting on developing a complete draft of the proposed new or revised NFPA standard, and only vote on changes to the document. The public input stage, similar to the current ROP stage, has been recast as a preliminary stage for assisting the committee in developing that draft and for raising new issues for public review and consideration. The committee will still review all public input and provide limited responses, however, the committee will not be required to formally accept or reject public input. The committee s focus, instead, will be on using the advice and input submitted by the public in order to develop a complete and fully integrated draft that will be known as the First Draft, which will be published for public comments (similar to the current ROC stage). The new process will be in effect for standards reporting in the Fall 2013 and subsequent revision cycles, therefore our current revision of NFPA 909 will be completed under the existing regulations and the next revision of NFPA 914 will be completed under the new Regulations. Committee members should start to familiarize themselves with the new Regulations, which can be downloaded at Staff will provide a more detailed review of the new process prior to the NFPA 914 ROP meeting. For an overview of the new process, visit the NFPA website at click on Codes and Standards, and see the Special Notice on NFPA Regulations. 6. REVIEW SCHEDULE FOR FUTURE COMMITTEE MEETINGS 1 Fall 2011 (NFPA 909 Pre ROC) Oakland, CA 8-9 th November. Shane Clary hoped to hold the meeting at the Oakland Museum of Californian History, however if this is not possible the meeting will be held in a nearby hotel with a visit to the museum arranged. 2 Spring 2012 (NFPA 909 ROC), Smithsonian Institution. Week of 23 April 2011, exact dates to be confirmed by host, Michael Kilby. 3 Fall 2102 (NFPA 914 Pre-ROP), Venice, Italy. Luca Nassi will host this meeting and will advise of location and dates in September NFPA 909 Cindy Greczek presented the NFPA 909 task group report with recommended actions on the public proposals for the revision of NFPA 909. The committee then acted on the proposals, which will be subject to a letter ballot. See the Fall 2012 Report on Proposals for the committee actions. 8. NFPA 914 The revision cycle for NFPA 914 commences in January 2013 with a notification of intent to enter cycle, and an issuance date of November 2014 (if no NITMAMs are received) or August 2015 (if NITMAMs are received and certified), pending appeals. 4 Page 9 of 41

10 Steve Peterson informed the committee that the NFPA 914 task group had conferred by conference calls and had held a short meeting in Vienna and have laid out several goals that the task group hope to achieve prior to the Oakland meeting; Security Provide the committee with a detailed outline of Goals and Objectives for the next revision cycle. It is anticipated that security will focus on arson, vandalism and terrorism. The committee will need to define how NFPA 914 will interface with NFPA 730, Guide for Premises Security, and define levels of protection based on the building s historic significance. It was suggested that terrorism should focus on monumental structures. Monumental versus Iconic Structures The goal for the Oakland meeting is to provide a definition and outline for development of this section. Rewrite Historic District Fire Code Chapter There is a need to review the current annex section and synthesize those issues common to the protection of historic districts, then provide a draft outline for development for the next revision cycle. It was suggested that, in order to address historic districts, our annex code should focus on development codes or zoning codes as a better format for organising our efforts. This would enable us to recognise that the protection of Historic Districts is usually one third political, one third economic and one third preservation. Case Studies The committee needs to define the case study goals and recommend a target number of additional case studies for the next revision cycle. Case studies are required for integration of fire protection measures, historic district protection, security measures and performance measures. Electronic Publication Jack Watts is to report on the feasibility of electronic publishing in light of NFPA s recent conversion to a public website and provide the committee with a recommendation to continue or abandon this goal. Performing Arts Centres There is a need to define the pros and cons of pursuing theatres as a new subject area for cultural resources and provide the committee with a recommendation to continue or abandon theatres as a new scope change, new document, or NFPA 914 additions. 9. PRESENTATION BY WOLFGANG BACHLER Wolfgang Bachler, head of security for Schloss Schönbrunn, gave a presentation where he introduced the strategic security concept that is being developed for Schloss Schönbrunn. He talked about Schönbrunn probably being the most important monument in Austria, making it a potential target. 5 Page 10 of 41

11 Wolfgang explained that the concept identified five levels of perpetrator. They have developed an escalation matrix for responding to threats; risk evaluation of various threats and special events, with the level of threat automatically dictating staff response. He also spoke about the importance of good communications and they have a prepared public communication response for specific situations. They have recognised the importance of covering Twitter and Facebook postings with their current goal of communication within thirty minutes of an incident, although they realise that a quicker response is ideal in this time of instant communication via the Internet. The integrated emergency and crisis management system is activated in an emergency through the Board. Wolfgang emphasised the importance of annual simulations to test the plan. 10. PROTECTING OUR HERITAGE Danny McDaniel advised that there had been a conference call to discuss the Protecting our Heritage publication and it would require a complete re-write. Danny does have a means of getting this published through an outside security association; however staff noted that NFPA owns the copyright on the publication and it is unlikely that NFPA would relinquish the copyright. Staff noted that if a revised publication is going to be spearheaded by this committee, NFPA should have the opportunity to support the activity and publish it. The Chair noted that previous requests were rebuffed by NFPA. Staff responded that no proposal or request has been presented to NFPA in the four years he has been staff liaison to the committee, and new product development is a currently a priority at NFPA business at NFPA is no longer business as usual, and thinking outside the box with regard to products is encouraged. The group looking at this publication will have to articulate the goals and objectives for the production of this document, consider who the document is aimed at, consider whether this sits within the scope of this committee, and consider how it would be published. Staff availed himself to provide whatever assistance is needed by the task group to get this initiative off the ground. 11. PORTABLE FIRE EXTINGUISHER AGENT TASK GROUP REPORT The group did not receive a grant from the Fire Protection Research Foundation for phase 2 of this project; however Cindy Greczek advised that Colonial Williamsburg will apply for an IMLS (Institute for Museum and Library Services) grant to proceed with this project. Emily Williams, Conservator of Archaeological Materials for Colonial Williamsburg, will be taking the lead in this project. There are still some issues that need to be addressed in relation to where the tests would be conducted and quantity and size of test samples. A project team is being developed to validate the review process. The group are still trying to secure some in-kind support from extinguisher manufacturers and Cindy would welcome any contacts that could assist in achieving this. 6 Page 11 of 41

12 The research will be carried out on a cross section of samples of material. They will be subjected to two different tests, one where the extinguishing agent is applied to material in fire conditions and one where there is no fire present. There will be an initial assessment of the material followed by a further assessment after six months and a final assessment six months later. The results should provide evidence to recommend types of fire fighting agent for various materials, with evidence of how they will react and recommendations for salvage or restoration. 12. AUTOMATIC SPRINKLER SYSTEMS ANTIFREEZE UPDATE Russ Fleming gave a presentation detailing the history of antifreeze in sprinkler systems and providing a timeline of antifreeze events from 2002 through to the present. In March 2011 the standards council issued new TIA s to NFPA 13, 13D, 13R, and 25 addressing all occupancies. This requires that only pre-mixed antifreeze solutions are to be used. The TIAs and latest antifreeze information can be viewed at: PRESENTATION ON L AQUILA EARTHQUAKE INTERVENTION AND SALVAGE Luca Nassi gave a presentation on the work completed in Italy to develop a national database following the L Aquila earthquake. The database provides public access to view information on properties whilst private areas enable the fire service and the cultural resources agencies to store information in a secure manner. Following the earthquake in L Aquila, there was a need to create documentation that would provide a risk assessment of the vulnerability of the building. A team consisting of an engineer or architect from the fire service, an engineer or architect from the Ministry of Cultural Heritage and a conservation expert completed the assessment of each building to determine the level of intervention that was required in the short-term to stabilise the building. This enabled a process of prioritisation to be developed. Luca also gave a short presentation on the MAP Project at the Villa Della Regina in Turin. Following a fire, the media had reported damage caused to a painting during fire fighting operations. It was established that the fire service did not know the location of artefacts, significance of these, how to rescue the contents, etc. Through this project it has been possible to provide information to the fire service and those involved in the building, the information being available through a hand-held device. 7 Page 12 of 41

13 14. EU ACTIVITIES UPDATE Mike Coull advised that the IFE special interest group are currently working on guidance for thatch, which will be available for homeowners and fire services. In relation to ongoing co-operation between European partners who were involved in the COST action, Historic Scotland and English Heritage are working with colleagues in Norway on a project which hopes to reduce the need for fire door testing of historic doors by producing a standard set of computer fire models. Wolfgang Kippes advised that following the conference on Wednesday, agreement now exists between the heritage agencies in Austria and Scotland for working in partnership on all aspects of heritage including fire and security. 15. OTHER BUSINESS Bill Jackson informed the committee that the IFE had held a meeting within the National Library of Scotland where Lubrizol gave a presentation. During the meeting Bill discussed the problems that the National Library has had. The LPC are recommending that they host a conference next year with 100 major insurers to ensure that the insurance industry is aware of the issues. The LPC are keen to hear of any other examples of problems with CPVC. 16. ADJOURNMENT The meeting was adjourned at 1510 on the 24 th June Minutes prepared by Mike Coull, Secretary 8 Page 13 of 41

14 909-3 Log #29 John F. Bender, Underwriters Laboratories Inc. Add new section and text as follows: UL Publications. Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL ANSI/UL 723 Standard for Test for Surface Burning Characteristics of Building Materials, 2008, Revised Add new Section to reference mandatory use of ANSI/UL 723 as currently referenced in Section Affirmative: 27 1 Chartier, J. ROCKLIN, S.: Editorial- should this be 2.3.3? 3 Page 14 of 41

15 909-4 Log #61 Marcelo M. Hirschler, GBH International Revise text to read as follows: ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA ASTM E 84, 2010b ASTM E 1591, G ASTM Publications. American Society for Testing and Materials, 100 Barr Harbor Drive, West Conshohocken, PA ASTM E 1355,, ASTM E 1472,, G.2.2 ASTM Publications. ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA ASTM E 84,, 2010b [ROC-1] ASTM E 136,, Standards update. Also ASTM E84 is referenced in section and needs to be added to section 2 and it is important to use a much more recent edition than Affirmative: 26 Negative: 1 1 Chartier, J. ROCKLIN, S.: The definition of alteration in NFPA 5000 includes modification, replacement or another physical change, and the 2009 edition continues the use of the term renovation, as well as modification. This change does not clarify the intent of the code. 4 Page 15 of 41

16 909-9 Log #CP19 Technical Committee on Cultural Resources, Revise definition to read as follows: A Building building characteristics and other conditions that are under the control of the design team. [, 2012] The proposal replaces the secondary definition of 'design specification' with the preferred definition from NFPA 5000, Building Construction and Safety Code. Affirmative: 26 Negative: 1 1 Chartier, J. WATTS, JR., J.: 1. The term in the current (2010) edition of 909 should be plural as printed in the 2005 edition. 2. NFPA 909 predominantly uses the plural term. 3. The term in the plural reflects a concept consistent with other terms in NFPA 909 such as collections and occupant characteristics. 4. The singular term definition from NFPA 5000 does not make sense since it uses the plural phrase conditions that are. 10 Page 16 of 41

17 Log #62 Marcelo M. Hirschler, GBH International New text to read as follows: Not capable of supporting combustion. 3.3.xx Noncombustible material. See xx Limited combustible material. See NFPA 909 uses the terms noncombustible material and limited combustible material repeatedly without properly defining them. NFPA 101 and NFPA 5000 have revised the definitions of noncombustible material and limited combustible material so that the definitions don t contain requirements or multiple sentences. The requirements are now contained in the body of the code or standard. This is also a way of dealing with uniformity of references within the NFPA system. For international users of the document I want to point out that ASTM E2652 is identical to ISO Neither ASTM E2652 nor ISO 1182 contain pass/fail criteria. The proposal does not add any requirements. 13 Page 17 of 41

18 1. Revise definitions as follows: Not capable of supporting combustion. See See Add a new and renumber subsequent paragraphs accordingly as follows: A material that complies with any of the following shall be considered a noncombustible material: (1)* A material that, in the form in which it is used and under the conditions anticipated, will not ignite, burn, support combustion, or release flammable vapors, when subjected to fire or heat (2) A material that is reported as passing ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 Degrees C (3) A material that is reported as complying with the pass/ fail criteria of ASTM E 136 when tested in accordance with the test method and procedure in ASTM E 2652, Standard Test Method for Behavior of Materials in a Tube Furnace with a Cone-shaped Airflow Stabilizer, at 750 Degrees C. [ : ] The provisions of do not require inherently noncombustible materials to be tested in order to be classified as noncombustible materials. [ :A ] Examples of such materials include steel, concrete, masonry and glass. [ :A (1)] Where the term limited-combustible is used in this Code, it shall also include the term noncombustible. [ : ] A material shall be considered a limited combustible material where all the conditions of and , and the conditions of either or are met. [ : ] The material shall not comply with the requirements for a noncombustible material, in accordance with [ : ] The material, in the form in which it is used, shall exhibit a potential heat value not exceeding 3500 Btu/lb (8141 kj/kg), when tested in accordance with NFPA 259, Standard Test Method for Potential Heat of Building Materials. [ : ] The material shall have the structural base of a noncombustible material with a surfacing not exceeding a thickness of 1/8 in. (3.2 mm) where the surfacing exhibits a flame spread index not greater than 50 when tested in accordance with ASTM E 84, Standard Test Method for Surface Burning Characteristics of Building Materials or ANSI/UL 723, Standard for Test for Surface Burning Characteristics of Building Materials. [ : ] The material shall be composed of materials that, in the form and thickness used, neither exhibit a flame spread index greater than 25 nor evidence of continued progressive combustion when tested in accordance with ASTM E 84 or ANSI/UL 723, and are of such composition that all surfaces that would be exposed by cutting through the material on any plane would neither exhibit a flame spread index greater than 25 nor exhibit evidence of continued progressive combustion when tested in accordance with ASTM E 84 or ANSI/UL 723. [ : ] Where the term limited-combustible is used in this Code, it shall also include the term noncombustible. [ : ] ***** 3. Add the following references to Chapter 2: NFPA 259, Standard Test Method for Potential Heat of Building Materials, 2013 edition. ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 Degrees C, 2009b. ASTM E 2652, Standard Test Method for Behavior of Materials in a Tube Furnace with a Cone-shaped Airflow Stabilizer, at 750 Degrees C, 2009a. ANSI/UL 723, Standard for Test for Surface Burning Characteristics of Building Materials, 2008, Revised The committee action relocates the proposed text to Chapter 9, New Construction, Addition, Alteration, and Renovation Projects, which is more appropriate than Chapter 4, Goals and Objectives. The action further editorially revises the proposal for consistency with the source document (NFPA 5000). Affirmative: 27 1 Chartier, J. ROCKLIN, S.: The technical aspects as approved by the committee are acceptable; however, chapter 9 prescribes processes and requirements. It would be appropriate to locate this material in chapter Page 18 of 41

19 Log #43 Danny L. McDaniel, Colonial Williamsburg Foundation Revise text to read as follows: Where steel pipe is used in dry pipe and preaction systems, the provisions of NFPA 13,, shall be applied assuming water supplies and environmental conditions that contribute to unusual corrosive properties, and a plan shall be developed to treat the system using one or more of the following methods: (1)* Install a water pipe that is corrosion resistant : Galvanized steel piping is not considered corrosion resistant for purposes of this requirement. As long as water and oxygen are present inside system piping galvanized coatings can corrode. When galvanized coatings fail the uncoated steel that remains corrodes at an accelerated rate. (2) Treat all water that enters the system using an approved corrosion inhibitor Install a preaction system that is charged with water (3) Use a continuous source of dry inert gas for pressure maintenance (34) Test the water supply for corrosivity prior to connection to the sprinkler system; require any source of compressed air used for pressure maintenance to be equipped with an air dryer or nitrogen separator; and implement Implement an approved plan for maintaining and monitoring the interior conditions of the pipe at established intervals and locations, to include (a) Testing water flow devices between the semiannual tests using a means that does not introduce fresh water into the system, (b) Drying system piping before returning systems to service after trip tests or other incidents that introduce water into system piping beyond the riser, (c) Inspecting for obstructions when any of the following conditions are observed: i. Pinhole leaks ii. Frequent operation of the system s air compressor(s) iii. Corrosion on the outside of pipe joints, fittings, or sprinklers iv. Pitting, nodules, tubercles, or carbuncles inside piping or valves v. Foreign material in water during drain tests or plugging of inspector s test connection(s) vi. Plugged sprinklers vii. Plugged piping in sprinkler systems dismantled during building alterations viii. Frequent false tripping of a dry pipe valve(s) with indications of corrosion inside the valve(s) ix. A 50 percent increase in the time required for water to travel to the inspector s test connection after the valve trips during a full flow trip test of a dry pipe sprinkler system when compared to the original system acceptance test The levels of corrosion that are being found in steel dry pipe and preaction sprinkler systems are unacceptable in cultural resource facilities. Corrosion occurs because of the presence of oxygen and water trapped in sprinkler system piping from low-points in the piping, water traps created at rolled groove joints, or moisture in the compressed air used to maintain pressure in the system. It is not feasible or cost effective to treat all water that enters a dry pipe or preaction system with a corrosion inhibitor; therefore, removing the root causes of corrosion from steel dry pipe and preaction systems, limiting the introduction of fresh, oxygen laden, water into the systems, and thorough inspections of the interior of steel sprinkler piping for indications of corrosion minimizes the potential for damage to cultural resource collections from leaking sprinkler piping. Research currently underway by the NFPA 13 Committee and an independent research project just getting underway by Factory Mutual are examining the corrosion issue and may result in other options to limit the effects of corrosion on sprinkler piping; however, in the interim, the methods outlined in the current text of the document, combined with the proposed additions to the section, represent the consensus of opinion on how to protect steel dry pipe and preaction piping based on a series of presentations to the Cultural Resources Committee by experts in the field of corrosion protection. Where the requirements go beyond the current requirements of NFPA 13 and 25, they do so because the nature of cultural resource collections, which often are irreplaceable, requires a higher standard of care, both in the protection of the facilities and collections from the effects of fire and from the effects of accidental exposure to water from leaking sprinkler piping. Accept the proposal revised as follows: Where steel pipe is used in dry pipe and preaction systems, the provisions of NFPA 13,, shall be applied assuming water supplies and environmental conditions that contribute 41 Page 19 of 41

20 to unusual corrosive properties, and a plan shall be developed to treat the system using at least one of the following methods: (1)* Install a water pipe sprinkler piping that is corrosion resistant (2) Treat all water that enters the system using an approved corrosion inhibitor Install a pre-primed preaction system, filled with water under normal conditions (3) Use a continuous source of dry inert gas for pressure maintenance (34) Test the water supply for corrosivity prior to connection to the sprinkler system (5) Equip any source of compressed air used for pressure maintenance with an air dryer or nitrogen separator (6) Implement an approved plan for maintaining and monitoring the interior conditions of the pipe at established intervals and locations, including all of the following: (a) Testing water flow devices between the semiannual tests using a means that does not introduce fresh water into the system (b) Drying system piping before returning systems to service after trip tests or other incidents that introduce water into system piping beyond the riser (c) Inspecting for obstructions when any of the following conditions are observed: i. Pinhole leaks ii. Frequent operation of system air compressor(s) iii. Corrosion on the outside of pipe joints, fittings, or sprinklers iv. Pitting, nodules, tubercles, or carbuncles inside piping or valves v. Foreign material in water during drain tests or plugging of inspector s test connection(s) vi. Plugged sprinklers vii. Plugged piping in sprinkler systems dismantled during building alterations viii. Frequent false tripping of a dry pipe valve(s) with indications of corrosion inside the valve(s) ix. A 50 percent increase in the time required for water to travel to the inspector s test connection after the valve trips during a full flow trip test of a dry pipe sprinkler system when compared to the original system acceptance test : Galvanized steel piping is not considered corrosion resistant for the purposes of this requirement. Where water and oxygen are present inside system piping, galvanized coatings can corrode. When galvanized coatings fail, the remaining uncoated steel corrodes at an accelerated rate. A The wording of is based on NFPA 13, paragraph The special sensitivity of cultural resource properties to water damage that could result from piping corrosion warrants the assumption of water supplies and environmental conditions that contribute to unusual corrosive properties. These options are based on those specified by NFPA 13 for applications where water supplies are known to be corrosive. They are required in this Code for steel dry-pipe and preaction systems because the levels of corrosion found in these systems are unacceptable for cultural resource facilities. Although NFPA 13 also allows the option of treating all water that enters the system with an approved corrosion inhibitor, experience using this option has not been satisfactory in cultural resource facilities due to potential formation of external crystals on piping and potential reduction in the service life of gaskets in mechanical couplings. This Code includes the additional option of using a pre-primed preaction system, in which the piping is normally filled with water. The committee action revises (2) to include the use of a pre-primed preaction sprinkler system, which is a preaction system that is normally filled with water at atmospheric pressure. In the event of a sprinkler or piping failure, only the static water in the piping will discharge due to gravity. The normal presence of water in the piping will inhibit corrsion. The revisions to A expand on the corrosion experiences of some cultural resource properties and explain the concept of the pre-primed preaction system. Other revisions are editorial and should meet the submitter's intent. Affirmative: 27 1 Chartier, J. FLEMING, R.: While the intent to minimize problems with automatic sprinkler system in cultural resource facilities is justified, care must be taken that the requirements intended to supplement NFPA 13 for these facilities do not introduce unexpected problems. Proposals , , , , , , , and should be given additional scrutiny during the public comment period, and the implied definition of a pre-primed preaction system (909-64) needs to be coordinated with the NFPA 13 Committee. 42 Page 20 of 41

21 Log #36 Danny L. McDaniel, Colonial Williamsburg Foundation Revise text to read as follows: During the 5-year inspection and test of the sprinkler system, the interior of portions of the piping near the sprinkler riser shall be physically inspected to determine the extent of corrosion present. An interior corrosion inspection of system piping and valves shall be conducted every 5 years. Where pitting, nodules, tubercles, or carbuncles are present, an obstruction investigation shall be conducted in accordance with the requirements of NFPA 25. Repairs shall be made as necessary. Fontana and Greene defined eight forms of corrosion, which are generally accepted and used (Fontana and Greene 1978, Roberge 2000). The eight main forms of corrosion include: (1) uniform corrosion, (2) pitting, (3) galvanic corrosion, (4) crevice corrosion, (5) selective leaching (parting), (6) erosion corrosion, (7) environmental cracking, and (8) intergranular corrosion (Fontana and Greene 1978). Microbiologically influenced corrosion (MIC) is included herein as a ninth form of corrosion, although it is usually a secondary factor, which accelerates or exacerbates the rate of another form of corrosion. Definitions of the different forms of corrosion are discussed below. a. Uniform (or general) corrosion a regular loss of a small quantity of metal over the entire area or over a large section of the total area, which is evenly distributed within a pipe(s). General thinning of the material persists until failure occurs (Fontana and Greene 1978, Roberge 2000, Borenstein 1994). An example is an exposed (unpainted and uncoated) steel tank with uniform rusting over its entire surface. b. Pitting a localized form of corrosion, results in holes or cavities in the metal. Pitting is considered to be one of the more destructive forms of corrosion and is often difficult to detect. Pits can be covered or open and normally grow in the direction of gravity, e.g., at the bottom of a horizontal surface (Fontana and Greene 1978, Roberge 2000, Borenstein 1994). c. Galvanic corrosion an electric potential exists between dissimilar metals in a conductive (corrosive) solution. The contact between the two materials allows electrons to transfer from one metal to the other. One metal acts as a cathode and the other as an anode. Corrosion usually occurs at the anodic metal only. d. Crevice corrosion a localized form of corrosion, occurs within crevices and other shielded areas on metal surfaces exposed to a stagnant corrosive solution. This form of corrosion usually occurs beneath gaskets, in holes, surface deposits, and in thread and groove joints. Crevice corrosion is also referred to as gasket corrosion, deposit corrosion, and under-deposit corrosion (Fontana and Greene 1978, Roberge 2000). e. Selective leaching the selective removal of one element from an alloy by corrosion. A common example is dezincification (selective removal of zinc) of un-stabilized brass, resulting in a porous copper structure (Fontana and Greene 1978, Roberge 2000). f. Erosion corrosion corrosion resulting from the cumulative damage of electrochemical reactions and mechanical effects. Erosion corrosion is the acceleration or increase in the rate of corrosion created by the relative movement of a corrosive fluid and a metal surface. Erosion corrosion is observed as grooves, gullies, waves, rounded holes, or valleys in a metal surface (Fontana and Greene 1978, Roberge 2000). g. Environmental cracking an acute form of localized corrosion caused by mechanical stresses, embrittlement, or fatigue (Fontana and Greene 1978, Roberge 2000). h. Intergranular corrosion corrosion caused by impurities at grain boundaries, enrichment of one alloying element, or depletion of one of the elements in the grain boundary areas. Weld decay is a form of intergranular corrosion that results from heating of the metal during the welding to within the sensitizing range (Fontana and Greene 1978, Roberge 2000). i. Microbiologically Influenced Corrosion (MIC) corrosion initiated or accelerated by the presence and activities of microorganisms, including bacteria and fungi. Colonies (also called bio-films and slimes) are formed on the surface of pipes among a variety of types or microbes. Microbes deposit iron, manganese, and various salts into the pipe surfaces, forming nodules, tubercles, and carbuncles. The formation of these deposits can obstruct water flow, and if the deposits are dislodged, they can block (plug) system piping, valves, and sprinklers. MIC also normally includes pitting, which can result in pinhole leaks. MIC is rarely the only form of corrosion present in a sprinkler system. MIC normally exacerbates another form of corrosion, such as general corrosion, crevice corrosion, and under-deposit corrosion (Borenstein 1994), +++ The levels of corrosion that are being found in steel dry pipe and preaction sprinkler systems are unacceptable in cultural resource facilities. The proposed language provides guidance to the owner on what to do to evaluate the rest of the sprinkler system if significant amounts of corrosion are present near the sprinkler riser. 43 Page 21 of 41

22 Revise as follows: * During the 5-year inspection and test of the sprinkler system, the interior of portions of the piping near the sprinkler riser shall be physically inspected to determine the extent of corrosion present. Interior corrosion inspections of system piping and valves shall be conducted at intervals not to exceed 5 years. Where pitting, nodules, tubercles, or carbuncles are present, an obstruction investigation shall be conducted in accordance with the requirements of NFPA 25. Repairs shall be made as necessary. The levels of corrosion that are being found in steel dry pipe and preaction sprinkler systems are unacceptable in cultural resource facilities. Fontana and Greene defined eight forms of corrosion, which are generally accepted and used (Fontana and Greene 1978, Roberge 2000). The eight main forms of corrosion include: (1) uniform corrosion, (2) pitting, (3) galvanic corrosion, (4) crevice corrosion, (5) selective leaching (parting), (6) erosion corrosion, (7) environmental cracking, and (8) intergranular corrosion (Fontana and Greene 1978). Microbiologically influenced corrosion (MIC) is included herein as a ninth form of corrosion, although it is usually a secondary factor, which accelerates or exacerbates the rate of another form of corrosion. Definitions of the different forms of corrosion are discussed below. a. Uniform (or general) corrosion a regular loss of a small quantity of metal over the entire area or over a large section of the total area, which is evenly distributed within a pipe(s). General thinning of the material persists until failure occurs (Fontana and Greene 1978, Roberge 2000, Borenstein 1994). An example is an exposed (unpainted and uncoated) steel tank with uniform rusting over its entire surface. b. Pitting a localized form of corrosion, results in holes or cavities in the metal. Pitting is considered to be one of the more destructive forms of corrosion and is often difficult to detect. Pits can be covered or open and normally grow in the direction of gravity, e.g., at the bottom of a horizontal surface (Fontana and Greene 1978, Roberge 2000, Borenstein 1994). c. Galvanic corrosion an electric potential exists between dissimilar metals in a conductive (corrosive) solution. The contact between the two materials allows electrons to transfer from one metal to the other. One metal acts as a cathode and the other as an anode. Corrosion usually occurs at the anodic metal only. d. Crevice corrosion a localized form of corrosion, occurs within crevices and other shielded areas on metal surfaces exposed to a stagnant corrosive solution. This form of corrosion usually occurs beneath gaskets, in holes, surface deposits, and in thread and groove joints. Crevice corrosion is also referred to as gasket corrosion, deposit corrosion, and under-deposit corrosion (Fontana and Greene 1978, Roberge 2000). e. Selective leaching the selective removal of one element from an alloy by corrosion. A common example is dezincification (selective removal of zinc) of un-stabilized brass, resulting in a porous copper structure (Fontana and Greene 1978, Roberge 2000). f. Erosion corrosion corrosion resulting from the cumulative damage of electrochemical reactions and mechanical effects. Erosion corrosion is the acceleration or increase in the rate of corrosion created by the relative movement of a corrosive fluid and a metal surface. Erosion corrosion is observed as grooves, gullies, waves, rounded holes, or valleys in a metal surface (Fontana and Greene 1978, Roberge 2000). g. Environmental cracking an acute form of localized corrosion caused by mechanical stresses, embrittlement, or fatigue (Fontana and Greene 1978, Roberge 2000). h. Intergranular corrosion corrosion caused by impurities at grain boundaries, enrichment of one alloying element, or depletion of one of the elements in the grain boundary areas. Weld decay is a form of intergranular corrosion that results from heating of the metal during the welding to within the sensitizing range (Fontana and Greene 1978, Roberge 2000). i. Microbiologically Influenced Corrosion (MIC) corrosion initiated or accelerated by the presence and activities of microorganisms, including bacteria and fungi. Colonies (also called bio-films and slimes) are formed on the surface of pipes among a variety of types or microbes. Microbes deposit iron, manganese, and various salts into the pipe surfaces, forming nodules, tubercles, and carbuncles. The formation of these deposits can obstruct water flow, and if the deposits are dislodged, they can block (plug) system piping, valves, and sprinklers. MIC also normally includes pitting, which can result in pinhole leaks. MIC is rarely the only form of corrosion present in a sprinkler system. MIC normally exacerbates another form of corrosion, such as general corrosion, crevice corrosion, and under-deposit corrosion (Borenstein 1994). The committee action editorially revises to require corrosion inspections at intervals not to exceed 5 years, rather than prescribe inspections at 5 year intervals. It also adds the first sentence of the 44 Page 22 of 41

The committee completed self-introductions. TECHNICAL COMMITTEE MEMBERS PRESENT REPRESENTING

The committee completed self-introductions. TECHNICAL COMMITTEE MEMBERS PRESENT REPRESENTING 1. CALL TO ORDER/WELCOME MEETING MINUTES NFPA Technical Committee on Cultural Resources NFPA 914 First Draft Meeting APRIL 23-24, 2013 Royal British Columbia Museum Victoria, British Columbia, Canada Don

More information

NFPA Technical Committee on Cultural Resources NFPA 909 ROC Meeting Agenda

NFPA Technical Committee on Cultural Resources NFPA 909 ROC Meeting Agenda NFPA Technical Committee on Cultural Resources NFPA 909 ROC Meeting Agenda April 24-25, 2012 National Museum of the American Indian Smithsonian Institution Washington, DC 1. Call to order, 9:00 AM, Tuesday,

More information

MEETING MINUTES. APRIL 27-29, 2015 Hyatt Regency Buffalo Hotel and Conference Center Buffalo, New York ORGANISATION

MEETING MINUTES. APRIL 27-29, 2015 Hyatt Regency Buffalo Hotel and Conference Center Buffalo, New York ORGANISATION MEETING MINUTES NFPA TECHNICAL COMMITTEE ON CULTURAL RESOURCES NFPA 909 FIRST DRAFT MEETING MINUTES APRIL 27-29, 2015 Hyatt Regency Buffalo Hotel and Conference Center Buffalo, New York MEMBERS PRESENT

More information

NFPA Technical Committee on Cultural Resources NFPA 914 Pre-First Draft Meeting Agenda

NFPA Technical Committee on Cultural Resources NFPA 914 Pre-First Draft Meeting Agenda NFPA Technical Committee on Cultural Resources NFPA 914 Pre-First Draft Meeting Agenda September 18-19, 2012 Scuola Grande di San Giovanni Evangelista Venice, ITALY 1. Call to order, 9:30 AM, Tuesday,

More information

MEETING MINUTES TECHNICAL COMMITTEE ON CULTURAL RESOURCES

MEETING MINUTES TECHNICAL COMMITTEE ON CULTURAL RESOURCES MEETING MINUTES TECHNICAL COMMITTEE ON CULTURAL RESOURCES OCTOBER 12-13, 2010 THE HENRY A. WALLACE CENTRE AT THE FDR PRESIDENTIAL LIBRARY AND HOME Hyde Park, New York MEMBERS PRESENT Deborah Freeland,

More information

NFPA Technical Committee on Cultural Resources (CUL-AAA) Agenda

NFPA Technical Committee on Cultural Resources (CUL-AAA) Agenda NFPA Technical Committee on Cultural Resources () Agenda October 12-13, 2010 The Henry A. Wallace Center at the FDR Presidential Library and Home Hyde Park, New York 1. Call to order, 9:00 AM, Tuesday,

More information

NFPA Technical Committee on Cultural Resources NFPA 909 ROP Meeting Agenda

NFPA Technical Committee on Cultural Resources NFPA 909 ROP Meeting Agenda NFPA Technical Committee on Cultural Resources NFPA 909 ROP Meeting Agenda June 23-25, 2011 Schloss Schönbrunn Vienna, Austria 1. Call to order, 9:00 AM, Thursday, June 23, 2011 D. Freeland. 2. Self-introduction

More information

NFPA Technical Committee on Cultural Resources NFPA 914 SECOND DRAFT MEETING AGENDA

NFPA Technical Committee on Cultural Resources NFPA 914 SECOND DRAFT MEETING AGENDA NFPA Technical Committee on Cultural Resources NFPA 914 SECOND DRAFT MEETING AGENDA April 24-25, 2014 Hilton Waikoloa Village Waikoloa, Hawaii 1. Call to Order. Call meeting to order by Chair Don Moeller,

More information

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved. Public Input No. 1-NFPA 557-2012 [ New Section after 1.5.3 ] 1.6 Approved Qualifications The design shall be prepared by a person with qualifications acceptable to the AHJ. The term designer is used in

More information

NFPA Technical Committee on Cultural Resources NFPA 909 Pre-First Draft Meeting Agenda

NFPA Technical Committee on Cultural Resources NFPA 909 Pre-First Draft Meeting Agenda NFPA Technical Committee on Cultural Resources NFPA 909 Pre-First Draft Meeting Agenda September 30-October 1, 2014 Old Faithful Snow Lodge Yellowstone National Park, Wyoming 1. Call to order, 9:00 AM,

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Cultural Resources

More information

M E M O R A N D U M. NFPA Technical Committee on Cultural Resources. Kelly Carey, Project Administrator. Date: July 9, 2014

M E M O R A N D U M. NFPA Technical Committee on Cultural Resources. Kelly Carey, Project Administrator. Date: July 9, 2014 National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M To: From: NFPA Technical Committee on Cultural Resources

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Merchant Vessels

More information

NFPA Technical Meeting (Tech Session) June 24-25, 2015 Agenda*

NFPA Technical Meeting (Tech Session) June 24-25, 2015 Agenda* NFPA Technical Meeting (Tech Session) June 24-25, 2015 Agenda* NFPA Standards presented for Action Wednesday, June 24, 2015 starting @ 2:00pm: NFPA 33, Standard for Spray Application Using Flammable or

More information

REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS

REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS REPORT OF THE NFPA MOTIONS COMMITTEE* ON FALL 2013 REVISION CYCLE STANDARDS I. Introduction. This is the Motions Committee Report on Standards in the Fall 2013 Revision Cycle. The report identifies Certified

More information

12/21/2015 National Fire Protection Association Report

12/21/2015 National Fire Protection Association Report http://submittals.nfpa.org/terraviewweb/viewerpage.jsp?id=232 2012.ditamap&toc=false&draft=true 1/9 Public Comment No. 1 NFPA 232 2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents

More information

TECHNICAL COMMITTEE ON SAFETY AT MOTORSPORTS VENUES. NFPA 610 First Draft Meeting. October 17-18, 2016

TECHNICAL COMMITTEE ON SAFETY AT MOTORSPORTS VENUES. NFPA 610 First Draft Meeting. October 17-18, 2016 TECHNICAL COMMITTEE ON SAFETY AT MOTORSPORTS VENUES NFPA 610 First Draft Meeting October 17-18, 2016 Westin Kansas City at Crown Center 1 East Pershing Road Kansas City, MO, 64108 Conference Call Access:

More information

TECHNICAL COMMITTEE ON FIRE CODE

TECHNICAL COMMITTEE ON FIRE CODE TECHNICAL COMMITTEE ON FIRE CODE M E M O R A N D U M TO: FROM: Technical Committee on Fire Code (FCC-AAA) Gregory Harrington, P.E., Staff Liaison DATE: February 3, 2011 SUBJECT: NFPA 1124 Amended CP#2

More information

NFPA 550 ROP Meeting Minutes

NFPA 550 ROP Meeting Minutes NFPA 550 ROP Meeting Minutes NFPA Technical Committee on Fire Risk Assessment Methods (FIR-AAA) June 24, 2010 Microsoft Live Meeting 1. Call to order. The meeting was called to order at 1:00 PM on Monday,

More information

NFPA Technical Committee on Hybrid (Water and Inert Gas) Fire Extinguishing Systems

NFPA Technical Committee on Hybrid (Water and Inert Gas) Fire Extinguishing Systems San Antonio, TX October 12-14, 2016 The following are the meeting minutes from the third meeting of the Technical Committee on Hybrid (Water and Inert Gas) Fire Extinguishing Systems held in San Antonio,

More information

Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document

Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] Statement of Problem and Substantiation for Public Input. Related Public Inputs for This Document 1 of 19 10/21/2015 1:20 PM Public Input No. 1-NFPA 99B-2015 [ Section No. 2.3 ] 2.3 Other Publications. 2.3.1 ASME Publications. American Society of Mechanical Engineers, Three ASME International, Two

More information

Second Revision No. 3-NFPA [ Section No. 2.3 ]

Second Revision No. 3-NFPA [ Section No. 2.3 ] Second Revision No. 3-NFPA 804-2014 [ Section No. 2.3 ] 2.3 Other Publications. 2.3.1 ASME Publications. American Society of Mechanical Engineers, Three Park Avenue, New York, NY 10016-5990. ASME Boiler

More information

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item

Public Comment No. 23-NFPA [ Section No ] Statement of Problem and Substantiation for Public Comment Related Item Public Comment No. 23-NFPA 96-2015 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM E84, Standard Test Method

More information

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement

6/9/ :58 PM. First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement First Revision No. 1-NFPA 259-2016 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM D5865, Standard Test Method

More information

National Fire Protection Association M E M O R A N D U M. NFPA Technical Committee on Construction and Demolition

National Fire Protection Association M E M O R A N D U M. NFPA Technical Committee on Construction and Demolition National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Construction

More information

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M To: From: NFPA Technical Committee on Helicopter Facilities

More information

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle)

M E M O R A N D U M. NFPA Technical Committee on Alternative Approaches to Life Safety. SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle) M E M O R A N D U M TO: FROM: NFPA Technical Committee on Alternative Approaches to Life Safety Linda MacKay DATE: December 28, 2010 SUBJECT: NFPA 101A ROP TC Letter Ballot (A2012 Cycle) The ROP letter

More information

FIF AAA (F2014) Second Draft Meeting Web/Teleconference Meeting Agenda March 18, :00 5:00 p.m. ET

FIF AAA (F2014) Second Draft Meeting Web/Teleconference Meeting Agenda March 18, :00 5:00 p.m. ET NFPA 804, Standard for Fire Protection for Advanced Light Water Reactor Electric Generating Plants, NFPA 805, Performance Based Standard for Fire Protection for Light Water Reactor Electric Generating

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Mercantile and

More information

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM

First Revision No. 2-NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of 11 1/18/2016 5:43 PM 1 of 11 1/18/2016 5:43 PM First Revision No. 2-NFPA 51-2015 [ Global Input ] Throughout standard remove references to the following and replace with the following: (1) CGA C-7 Guide to Precautionary Labelling

More information

National Fire Protection Association M E M O R A N D U M. NFPA Technical Committee on Cultural Resources

National Fire Protection Association M E M O R A N D U M. NFPA Technical Committee on Cultural Resources National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Cultural Resources

More information

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input

1/8/ :02 AM. Public Input No. 2-NFPA [ Section No ] Statement of Problem and Substantiation for Public Input Public Input No. 2-NFPA 259-2015 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM D 5865, Standard Test Method

More information

ROP MEETING MINUTES. 2. Introduction of Attendees. The following committee members and guests were in attendance. TECHNICAL COMMITTEE MEMBERS PRESENT

ROP MEETING MINUTES. 2. Introduction of Attendees. The following committee members and guests were in attendance. TECHNICAL COMMITTEE MEMBERS PRESENT BLD/SAF-FIR 24-25 September 2009 ROP Meeting Minutes ROP MEETING MINUTES Building Code Life Safety Technical Committee on Fire Protection Features Thursday-Friday, September 24-25, 2009 Meeting Embassy

More information

Preliminary Agenda Technical Committee on Liquefied Petroleum Gas

Preliminary Agenda Technical Committee on Liquefied Petroleum Gas Preliminary Agenda Technical Committee on Liquefied Petroleum Gas Tuesday, March 10; All Day Wednesday, March 11; All Day DRURY PLAZA HOTEL San Antonio Riverwalk 0. Administrative. A. Meeting Schedule.

More information

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ]

Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ] Public Input No. 1-NFPA 90B-2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be considered

More information

Report on Proposals F2007 Copyright, NFPA NFPA 499 Report of the Committee on

Report on Proposals F2007 Copyright, NFPA NFPA 499 Report of the Committee on Report on Proposals F2007 Copyright, NFPA NFPA 499 Report of the Committee on This list represents the membership at the time the Committee was balloted on the text of this edition. Since that time, changes

More information

SC # /16/17/18/19/23/24 D#03-24

SC # /16/17/18/19/23/24 D#03-24 SC #03-7-15/16/17/18/19/23/24 D#03-24 Casey C. Grant, P.E. Secretary, Standards Council 26 July 2003 To: Interested Parties Subject: Standards Council Decision (Final): D#03-24 Standards Council Agenda

More information

NFPA Technical Committee on Fire Tests FALL 2010 ROC MEETING MINUTES April 15-16, 2010 Southwest Research Institute San Antonio, TX

NFPA Technical Committee on Fire Tests FALL 2010 ROC MEETING MINUTES April 15-16, 2010 Southwest Research Institute San Antonio, TX NFPA Technical Committee on Fire Tests FALL 2010 ROC MEETING MINUTES April 15-16, 2010 Southwest Research Institute San Antonio, TX 1. Call to Order. The meeting of the Technical Committee on Fire Tests

More information

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes

First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] Submitter Information Verification. Committee Statement and Meeting Notes First Revision No. 6-NFPA 90A-2012 [ Chapter NFPA ] 4.3.11.5.5 Materials within a raised floor plenum exposed to the airflow shall be (a) noncombustible or (b) exhibit a maximum flame spread index of 25

More information

MEMORANDUM. NFPA 51 First Draft Technical Committee FINAL Ballot Results (A2017 Cycle)

MEMORANDUM. NFPA 51 First Draft Technical Committee FINAL Ballot Results (A2017 Cycle) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM TO: FROM: Technical Committee on Industrial and Medical Gases

More information

Introductions made by the Chair, committee members, NFPA Staff Liaison, Jacqueline Wilmot and Dan Gorham of the Fire Protection Research Foundation.

Introductions made by the Chair, committee members, NFPA Staff Liaison, Jacqueline Wilmot and Dan Gorham of the Fire Protection Research Foundation. NFPA Technical Committee On Fire Hose NFPA 1961 Minutes Task Group Update Underwriters Laboratory November 15 th - 16 th 2016 Tuesday, November 15 th, 2016 Meeting called to order at 8:07 AM by Chairman

More information

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement

Second Revision No. 1-NFPA 90A-2016 [ Section No ] Submitter Information Verification. Committee Statement Second Revision No. 1-NFPA 90A-2016 [ Section No. 2.3.2 ] 2.3.2 ASTM International Publications. ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959. ASTM C411, Standard

More information

Technical Committee on Water Mist Fire Suppression Systems

Technical Committee on Water Mist Fire Suppression Systems Date: January 29, 2013 1. Call to Order. Meeting was called to order by Chair Larry Owen at 8:00 AM. 2. Building Safety Message. Building safety was discussed and exits identified by Chair Larry Owen.

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Hot Work Operations

More information

TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, :00 AM - 5:00 PM EST Web/Teleconference Meeting

TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, :00 AM - 5:00 PM EST Web/Teleconference Meeting TECHNICAL COMMITTEE ON MANUFACTURE OF ORGANIC COATINGS First Draft Meeting Agenda March 19, 2014 9:00 AM - 5:00 PM EST Web/Teleconference Meeting 1. Welcome. George Seuss, Chair 2. Introductions and Update

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: Technical Committee on Standpipes Elena

More information

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] 1.3 Application. 1.3.1 This standard shall apply to all systems for the movement of environmental air in structures that serve the following, except

More information

1. Call to Order. The meeting was called to order at 1:05 PM. (See Enclosure A [Agenda])

1. Call to Order. The meeting was called to order at 1:05 PM. (See Enclosure A [Agenda]) FINAL MINUTES Healthcare Interpretations Task Force Tuesday, June 15, 2016 Mandalay Bay Convention Center South Convention Center, Level 2 Room Surf F Las Vegas, NV 1. Call to Order. The meeting was called

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Mercantile and

More information

Public Input No. 3-NFPA [ Chapter 2 ]

Public Input No. 3-NFPA [ Chapter 2 ] Public Input No. 3-NFPA 655-2014 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be considered

More information

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax: National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Mercantile and

More information

NFPA Technical Committee on Fire Tests

NFPA Technical Committee on Fire Tests National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Fire Tests Tracy

More information

"Spray area" is the term that is used throughout the document. This change is for consistency.

Spray area is the term that is used throughout the document. This change is for consistency. of 78 5/30/2014 2:08 PM Public Comment No. 39-NFPA 33-2013 [ Global Input ] For Chapter 18, replace "spray paint area" with "spray area". "Spray area" is the term that is used throughout the document.

More information

NFPA Technical Committee on Fire Tests FALL 2011 ROC MEETING MINUTES

NFPA Technical Committee on Fire Tests FALL 2011 ROC MEETING MINUTES National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org NFPA Technical Committee on Fire Tests FALL 2011 ROC MEETING MINUTES 1.

More information

Technical Committee on Record Protection (REA-AAA)

Technical Committee on Record Protection (REA-AAA) Technical Committee on Record Protection (REA-AAA) DATE: September 8, 2015 TO: FROM: M E M O R A N D U M Principal and Alternate Members of the Technical Committee on Record Protection (REA-AAA) Audrey

More information

Quantifying the Impact of Portable Fire Extinguisher Agents on Cultural Resource Materials: Fire and Non- Fire Exposure Tests

Quantifying the Impact of Portable Fire Extinguisher Agents on Cultural Resource Materials: Fire and Non- Fire Exposure Tests Quantifying the Impact of Portable Fire Extinguisher Agents on Cultural Resource Materials: Fire and Non- Fire Exposure Tests Matthew E. Benfer, Joseph L. Scheffey, and Eric W. Forssell (JENSEN HUGHES)

More information

Second Revision No. 1 NFPA [ Chapter 2 ]

Second Revision No. 1 NFPA [ Chapter 2 ] Second Revision No. 1 NFPA 232 2015 [ Chapter 2 ] Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard and shall be

More information

Minutes of the Pre-ROP Meeting of the T/C on Protected Premises Signaling September 22-23, 2010 Indianapolis, IN

Minutes of the Pre-ROP Meeting of the T/C on Protected Premises Signaling September 22-23, 2010 Indianapolis, IN Minutes of the Pre-ROP Meeting of the T/C on Protected Premises Signaling September 22-23, 2010 Indianapolis, IN Mr. Merton Bunker, Committee Chair, called the meeting to order at 8:05 on Wednesday September

More information

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Service and Fire Protection Equipment Gregory Harrington, P.E., Staff Liaison DATE: October 1, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter

More information

MEMORANDUM. NFPA Technical Committee on Fire Code (FCC-AAA) Subject: NFPA 1 Proposed Tentative Interim Amendment (TIA) No.1045

MEMORANDUM. NFPA Technical Committee on Fire Code (FCC-AAA) Subject: NFPA 1 Proposed Tentative Interim Amendment (TIA) No.1045 National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Fire Code (FCC-AAA) Gregory

More information

2016 Annual Revision Cycle Consent Document NFPA 75

2016 Annual Revision Cycle Consent Document NFPA 75 2016 Annual Revision Cycle Consent Document NFPA 75 The Committee on Electronic Computer Systems produced a Technical Committee Report that received at least one Notice of Intent to Make a Motion (NITMAM)

More information

White Paper. Monitoring Corrosion in Water Based Fire Sprinkler Systems (July 2013) By Jeffrey Kochelek V.1.0.0

White Paper. Monitoring Corrosion in Water Based Fire Sprinkler Systems (July 2013) By Jeffrey Kochelek V.1.0.0 White Paper Monitoring Corrosion in Water Based Fire Sprinkler Systems (July 2013) By Jeffrey Kochelek V.1.0.0 Copyright 2013 Engineered Corrosion Solutions, LLC. All rights reserved. This white paper

More information

FINAL* REPORT OF THE MOTIONS COMMITTEE

FINAL* REPORT OF THE MOTIONS COMMITTEE FINAL* REPORT OF THE MOTIONS COMMITTEE ON CERTIFIED AMENDING MOTIONS FOR PRESENTATION AT THE 2012 ASSOCIATION TECHNICAL MEETING JUNE 13-14, 2012 LAS VEGAS, NEVADA I. Introduction. This is the second and

More information

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement 1 of 7 3/4/2016 12:02 PM Second Revision No. 5-NFPA 56-2016 [ Section No. 1.1.2 ] 1.1.2 Nonapplication of Standard. This standard shall not apply to the following items: (1)* Piping systems covered by

More information

NFPA s Standards Development Process

NFPA s Standards Development Process NFPA s Standards Development Process Revision Cycle 104 weeks or 141 weeks Guiding Principles Due process Openness Lack of dominance Seek society s balance between: Acceptable risk Commitment of resources

More information

MEETING AGENDA High Rise Building Safety Advisory Committee

MEETING AGENDA High Rise Building Safety Advisory Committee MEETING AGENDA High Rise Building Safety Advisory Committee Renaissance Blackstone Chicago 636 South Michigan Avenue, Chicago, IL 60605 May 13-14, 2014 Chicago, IL 1. Call to Order. Call the meeting to

More information

Change all instances of "flame resistant (hypobaric)" to "Limited-Combustible (material)" in all instances in the document.

Change all instances of flame resistant (hypobaric) to Limited-Combustible (material) in all instances in the document. 1 of 9 10/21/2015 1:22 PM First Revision No. 3-NFPA 99B-2015 [ Global Input ] Change all instances of "flame resistant (hypobaric)" to "Limited-Combustible (material)" in all instances in the document.

More information

NFPA Technical Committee on Building Systems. NFPA 900 First Draft Teleconference/Web Meeting AGENDA. Thursday, February 13, :00 a.m.

NFPA Technical Committee on Building Systems. NFPA 900 First Draft Teleconference/Web Meeting AGENDA. Thursday, February 13, :00 a.m. 1. Call to Order: NFPA Technical Committee on Building Systems NFPA 900 First Draft Teleconference/Web Meeting AGENDA Thursday, February 13, 2014 11:00 a.m. Noon EDT Online meeting link: http://nfpa.adobeconnect.com/r366m2eaxx6/

More information

MEETING MINUTES NFPA Technical Correlating Committee on Safety to Life January 6, 2011 ROC Meeting The Wyndham Phoenix, Phoenix, AZ

MEETING MINUTES NFPA Technical Correlating Committee on Safety to Life January 6, 2011 ROC Meeting The Wyndham Phoenix, Phoenix, AZ MEETING MINUTES NFPA Technical Correlating Committee on Safety to Life January 6, 2011 ROC Meeting The Wyndham Phoenix, Phoenix, AZ 1. Call to Order. The meeting was called to order by Chair William Koffel

More information

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ]

Public Input No. 52-NFPA [ Section No [Excluding any Sub-Sections] ] 8 of 93 11/6/2015 7:41 AM Public Input No. 52-NFPA 30-2015 [ Section No. 21.2 [Excluding any Sub-Sections] ] For the purpose of this chapter, the term in this section shall have the definitions given.

More information

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM

Committee Input No NFPA [ Global Input ] Submitter Information Verification. Committee Statement. 1 of /20/ :02 AM 1 of 213 10/20/2016 11:02 AM Committee Input No. 2505-NFPA 72-2016 [ Global Input ] Change the term visible to visual where appropriate Submitter Information Verification Submitter Full Name: SIG-NAS Organization:

More information

Committee on NFPA 51A

Committee on NFPA 51A Committee on M E M O R A N D U M TO: FROM: NFPA Technical Committee on Industrial and Medical Gases Patti Mucci, Administrative Assistant DATE: May 6, 2010 SUBJECT: ROC Letter Ballot The ROC letter ballot

More information

Committee on NFPA 85

Committee on NFPA 85 Committee on NFPA 85 M E M O R A N D U M TO: FROM: NFPA Technical Committee on Single Burner Boilers Patti Mucci, Technical Assistant II DATE: August 5, 2009 SUBJECT: NFPA ROP Letter Ballot The ROP letter

More information

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169 7471 Phone: 617 770 3000 Fax: 617 770 0700 www.nfpa.org M E M O R A N D U M TO: FROM: NFPA Technical Committee on Furnishings

More information

MEETING AGENDA High Rise Building Safety Advisory Committee

MEETING AGENDA High Rise Building Safety Advisory Committee MEETING AGENDA High Rise Building Safety Advisory Committee March 4, 2015 Teleconference/Web Meeting 1. Call to Order. Call the meeting to order by Chair, Jim Quiter, at 1:00 pm EST on Wednesday, March

More information

home smoke candles alarms electrical burns smoking medical oxygen cooking FIREFIGHTING MATCHES & LIGHTERS SPRINKLERS

home smoke candles alarms electrical burns smoking medical oxygen cooking FIREFIGHTING MATCHES & LIGHTERS SPRINKLERS FIREFIGHTING home smoke alarms REGULATIONS GOVERNING THE NFPA EDUCATIONAL MESSAGES DESK REFERENCE FOR THE FIRE SERVICE AND FIRE AND LIFE SAFETY EDUCATORS MATCHES & LIGHTERS medical oxygen cooking FIRE

More information

First Revision No. 20-NFPA [ Section No ]

First Revision No. 20-NFPA [ Section No ] of 25 7/15/2015 8:30 AM First Revision No. 20-NFPA 56-2015 [ Section No. 1.1.2 ] 1.1.2 Nonapplication of Standard. This standard shall not apply to the following items: (1)* Piping systems covered by NFPA

More information

Agenda. If you are participating via Microsoft Live Meeting, here is the web address to join the Live Meeting:

Agenda. If you are participating via Microsoft Live Meeting, here is the web address to join the Live Meeting: Agenda NFPA Technical Committee on Manufactured Housing Fall 2012 Report on Comments Tuesday, April 10, 2012 from Noon to 5:00 PM Wednesday, April 11, 2012 from 8:00 AM to 5:00 PM (CDT) Hilton Garden Inn

More information

TECHNICAL COMMITTEE MEMBERS PRESENT

TECHNICAL COMMITTEE MEMBERS PRESENT National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0770 www.nfpa.org MINUTES NFPA Technical on Fire Doors and Windows NFPA 80 and NFPA 105

More information

Technical Committee on Fluidized Bed Boilers

Technical Committee on Fluidized Bed Boilers Technical on Fluidized Bed Boilers AGENDA Web/Teleconference 1. Chair s welcome, call to order, and opening remarks at 1:00 pm EST. 2. Self-Introduction of Members and Guests 3. Approval of Minutes from

More information

TECHNICAL COMMITTEE MEMBERS WHO PARTICIPATED

TECHNICAL COMMITTEE MEMBERS WHO PARTICIPATED MEETING MINUTES NFPA Correlating Committee on Safety to Life (SAF-AAC) November 7, 2013 Second Draft Meeting Embassy Suites Atlanta Hartsfield Airport Hotel Atlanta, GA 1. Call to Order. The meeting was

More information

Correlating Committee on Automatic Sprinkler Systems

Correlating Committee on Automatic Sprinkler Systems Correlating Committee on Automatic Sprinkler Systems M E M O R A N D U M DATE: May 14, 2014 TO: FROM: Principal and Alternate Members of the Correlating Committee on Automatic Sprinkler Systems Matt Klaus,

More information

CHAPTER 6 [CE] REFERENCED STANDARDS

CHAPTER 6 [CE] REFERENCED STANDARDS CHAPTER 6 [CE] REFERENCED STANDARDS User note: About this chapter: Chapter 6 lists the full title, edition year and address of the promulgator for all standards that are referenced in the code. The section

More information

Public Comment No. 2-NFPA [ Section No ]

Public Comment No. 2-NFPA [ Section No ] Page 1 of 13 Public Comment No. 2-NFPA 703-2013 [ Section No. 2.3.1 ] 2.3.1 ASTM Publications. ASTM International, P.O. Box C700, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959. ASTM D 2898, Standard

More information

FINAL* REPORT OF THE MOTIONS COMMITTEE

FINAL* REPORT OF THE MOTIONS COMMITTEE FINAL* REPORT OF THE MOTIONS COMMITTEE ON CERTIFIED AMENDING MOTIONS FOR PRESENTATION AT THE 2014 ASSOCIATION TECHNICAL MEETING JUNE 9-12, 2014 LAS VEGAS, NEVADA I. Introduction This is the second and

More information

PROPOSAL BALLOT DUE BY: Thursday, September 18, 2008

PROPOSAL BALLOT DUE BY: Thursday, September 18, 2008 PROPOSAL BALLOT DUE BY: Thursday, September 18, 2008 NFPA 204 SMO-AAA Standard for Smoke and Heat Venting Staff Liaison: Return Completed Ballot To: Jill McGovern E-Mail to jmcgovern@nfpa.org Fax to 617-984-7110

More information

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016) National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Solvent Extraction Plants

More information

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Public Input No. 1-NFPA [ Global Input ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification Public Input No. 1-NFPA 36-2013 [ Global Input ] Revise the document to eliminate the use of "Exception" text. The use of "Exception" text is inconsistent with the Manual of Style. Exception text should

More information

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference

Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference Matthews, Diane Subject: Location: Start: End: Show Time As: Recurrence: Meeting Status: Organizer: Required Attendees: Adobe Connect - Invitation to NFPA 385 Second Draft Web Conference http://nfpa.adobeconnect.com/rpbmeet/

More information

The Antifreeze Fire Sprinkler System Dilemma Eliminating One Issue has Opened the Door to Another. Jennifer Poynter, Esq. Charles B.

The Antifreeze Fire Sprinkler System Dilemma Eliminating One Issue has Opened the Door to Another. Jennifer Poynter, Esq. Charles B. The Antifreeze Fire Sprinkler System Dilemma Eliminating One Issue has Opened the Door to Another Jennifer Poynter, Esq. Charles B. Sullivan Wide Spread Impact of Code Changes Based on information available

More information

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot. National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org MEMORANDUM To: From: NFPA Technical Committee on Portable Fire Extinguishers

More information

Standards and Safety Update

Standards and Safety Update Standards and Safety Update Presented By: Michael J. Johnston Executive Director Standards and Safety, NECA Update Objectives Update on NFPA 70E and NECA Safety products Update on NECA S National Electrical

More information

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A. International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.800(19) Magnus Arvidson SP Fire Research SP Technical Research Institute

More information

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment M E M O R A N D U M TO: FROM: NFPA Technical Committee on Building Services and Fire Protection Equipment Linda MacKay DATE: November 10, 2009 SUBJECT: NFPA 5000 A2011 ROP Letter Ballot Final Results The

More information

Understanding, Applying and Enforcing NFPA 25. James D. Lake NFSA Director of Training

Understanding, Applying and Enforcing NFPA 25. James D. Lake NFSA Director of Training Understanding, Applying and Enforcing NFPA 25 James D. Lake NFSA Director of Training When Sprinklers Are Ineffective Water did not reach fire 8% 7% 7% 5% 44% Not enough water released Damaged Component

More information

Correlating Committee on Automatic Sprinklers

Correlating Committee on Automatic Sprinklers Correlating Committee on Automatic Sprinklers First Draft Correlating Committee Meeting December 6, 2016 MEETING MINUTES 1. Call to Order. CC Chair Ken Linder called the meeting to order at 8AM. 2. Self-Introductions

More information

NOTTINGHAM CITY HOMES

NOTTINGHAM CITY HOMES APPENDIX 1 NOTTINGHAM CITY HOMES FIRE SAFETY POLICY 2013/14 Draft for Board Uncontrolled when printed Page 1 of 14 DOCUMENT CONTROL Identification and Approval Status Document Title: Nottingham City Homes

More information

Report on First Revision November 2013 NFPA 750

Report on First Revision November 2013 NFPA 750 750 FR1 (Chapter 2) Recommendation: Update the following references: Chapter 2 Referenced Publications 2.1 General. The documents or portions thereof listed in this chapter are referenced within this standard

More information