1 REQUEST FOR QUOTATION [RFQ] No. : POS8120 FOR THE PROVISION OF MAINTENANCE FOR HEATING VENTILATION AND AIR CONDITIONER (HVAC) SYSTEM ISSUE DATE : 2 SEPTEMBER 2014 CLOSING DATE : 16 SEPTEMBER 2014 CLOSING TIME : 12:00 Page 1 of 20

2 Part 1 NOTICE TO TENDERERS Quotations which must be completed as indicated in Part 2 of this RFQ are to be submitted as follows: METHOD: [ ] ADDRESS: nthabisengm@cefgroup.co.za 1 Submissions to RFQ Submissions to this RFQ [Quotations] must not include documents or reference relating to any other quotation or Quotation. Any additional conditions must be embodied in an accompanying letter. 2 Scope of Work The Service Provide will conduct a comprehensive maintenance work on the Airconditioning and ventilation to be carried out on the following equipment listed below: Air Handling Unit (AHU) Fan Coil Unit (FCU) Diffusers Fans MCC Panels Splint Units Wall Mount Controls Water treatment 2.1 Equipment s Ciat Air Cooled Chillers Chilled Water Pumps Air Handling Units Fans (Extract) Page 2 of 20

3 2.1.5 Fan Coil Units Ducting Diffusers Split Units AC distribution boards 2.2 DETAILED SERVICE PROCEDURE 2 x Ciat Air Cooled Chillers LDC 800V Service will include: Check electrical connections and switchgear and inspect contact points Check control set up and set parameters Check gas charges at full running load Check for leaks Check evaporator approach temp and report findings Check condenser approach temp and report finding Check function and operations of chillers Check running pressure and log Check load unload sequence of chillers Check all safeties and water flow interlocks Check oil heaters Check oil filters Check compressor oil levels Taking compressor oil for analysis if necessary (change oil only if tests report indicates that oil is not fit for further use.) Change refrigerant filters if required Clean condenser coils Check condenser approach temp and report findings Mega test motors to earth Log chillers Report any other faults outside the attached report. 2.3 CHILLED WATER PUMPS Page 3 of 20

4 Service of the pumps will include: Checking oil level and toping up if required Assessing vibration of the pump Checking general condition of the pumps Cleaning switchboards and control panels Inspect electrical switchgear and tightening all terminals 2.4 AIR HANDLING UNITS Service General cleaning of the units and clean all washable air filters Clean all panels and check for damages Heat exchange coils will be cleaned All heater elements will be checked All V-belts will be checked for correct tension and alignment Pulleys will be checked and replaced if necessary Switchboards and electrical panels will be cleaned and electrical components Will be checked for defect and replaced if required Vibration and general operation will be checked and recorded All ferrous metal components will be examined and corrosion be treated All fan bearings will be checked and greased 2.5 SPLIT AIR-CONDITIONING UNITS Split type air-conditioning units includes: console units; mid and high wall split; under ceiling split and cassette type split. Service Cooling and heating operation will be checked Fan and Fan Motor operations be checked General cleaning will be carried out Evaporator and Condenser coils must be chemically cleaned Condensate panel be removed and cleaned Refrigerant system be leak tested Page 4 of 20

5 2.5.7 Operation of the unit be checked and any malfunction be reported All ferrous metal components will be checked for rust and treated if necessary 2.6 FAN COIL UNITS Fan coil units include ducted hideaway and cassette type Service All filter media will be removed and washed Condensate panel will be removed and cleaned Heating and cooling operation will be checked Heat exchanger coils will be chemically cleaned All flexible duct be checked for air leaks Electrical and control components be checked General operation of all units be checked and recorded Ferrous metal components will be checked for rust and treated if required 2.7 EXTRACT FANS Service General operation will be checked, fans will be checked for abnormal vibrations and all electrical connections will be checked and tightened 2.8 DUCTING If remedial work is required, this should be addressed with the Logistics and Facilities Manager 2.9 DIFFUSERS Service All diffuser will be cleaned and VAV diffusers service will be carried out as follows: Operation of motor will be checked Heater wiring will be checked and tightened if required Operation of heaters will be checked. Page 5 of 20

6 2.10 AC DISTRIBUTION BOARDS Service Panels will be internally cleaned Terminals will be checked and tightened LED globes be checked and replaced Starters, contactors and relays will be checked to ensure moving bridges slide freely and all contacts are cleaned Excessive burning of contacts must be investigated and rectified Amperage of all equipment must be checked ( refer to report attached) Electrical heater connections will be checked for correct amperage and faulty elements will be recorded Thermal overload setting will be checked and reset if require Insulation resistance be checked Automatic operation sequence will be checked Panel labelling be checked 2.11 WATER TREATMENT The contractor must take water samples and provide test report. If the test shows a need to dose chemicals (for corrosion and scale inhibitors chemicals) this must be communicated to the Logistics and Facilities REPAIRS These shall be reported to the Logistics and Facilities Manager verbally followed by a written quotation to facilitate the necessary repairs. An official order will be required before work is carried out. GENERAL The Service provider will not unduly disturb the occupants in the area/s concerned. The contractor will replace and fix all screws, bolts and nuts if necessary. Page 6 of 20

7 Acknowledgement of service and report will be completed by the service provider and signed by the Logistics and Facilities Manager. Reports will be given on all remedial work undertaken and on any fault found and replacements and repair required. 3 Assessment Report The report will be a guideline of the current challenges, if there are any requirements over and above what has been noted on the report (excluding the chillers as they are not covered in this report) service provider is requested to indicate such to the Logistics and Facility manager. Fresh air unit Fan =ok Heater elements drawing +_22Amps per phase. (Circuit breakers need upgrading as the current ones are 20A) Heaters all switching correctly. Filters need washing M400 cooling valve actuator is faulty and needs replacement. Dirt filter switch faulty needs to be replaced. Supply water temp sensor faulty. Return water temperature sensor faulty Controller logic improved for triac operation. Overall the system is not maintaining a good supply air temperature with the heaters on, a possible contributor to this is the missing heater element. (Cooling is undetermined as chiller is off and we are currently in winter). Atrium unit Fan=ok Heater triac element has been removed. (To be supplied) Heater step 3 interlock wiring error- this has been corrected for safe operation. Filters need to be replaced (To be supplied) Cooling valve actuator stem was found dislodged from stem. (Needs both lock nuts to be installed) Page 7 of 20

8 Mains electrical feeder is to small and needs to be upgraded (Current unit installed =20A) 3 pole Return water temp sensor faulty. Outside air temperature sensor is faulty. Controller logic improved for triac operation. Overall the unit operation is good as we are managing to maintain a good supply air temperature with the heaters on. (Cooling is undetermined as chiller is off and we are currently in winter) Ground Floor Air Handling Units Unit 01 Cooling valve actuator found to be modulating inconsistently and wiring error found and corrected. Run down timer found to be bridged out ( managed to change the electrical wiring to correct the issue) Filters very dirty. Static pressure is very low and air volumes not being achieved due to dirty filters. Pipe sensors = Ok Variable speed drive operation= ok Field diffusers don t appear to be functional as current being drawn is too low.(red phase=4 amps White=6 Blue =0) Return air temperature sensor=ok Supply air temperature sensor=ok Unit 02 Cooling valve actuator =Ok Run down timer = ok Filters very dirty. Static pressure is very low and air volumes not being achieved due to dirty filters. Pipe sensors = Ok Variable speed drive operation= ok Field diffusers don t appear to be partly functional.(red phase=25 amps White=27 Blue =23) Page 8 of 20

9 Return air temperature sensor=ok Supply air temperature sensor=ok First Floor Air Handling Units Unit 01 Cooling valve actuator =Ok Run down timer = ok Filters very dirty. Static pressure is very low and air volumes not being achieved due to dirty filters. Pipe sensors = Ok Variable speed drive operation= ok Field diffusers don t appear to be functional as current being drawn is too low.(red phase=0 amps White=0 Blue =0) Return air temperature sensor=ok Supply air temperature sensor=ok Unit 02 Cooling valve actuator =Ok Run down timer = ok Filters very dirty. Static pressure is very low and air volumes not being achieved due to dirty filters. Pipe sensors = Ok Variable speed drive operation= ok Field diffusers don t appear to be functional as current being drawn is too low.(red phase=0 amps White=2.4 Blue =6.4) Return air temperature sensor=ok Supply air temperature sensor=ok Second Floor Air Handling Units Unit 01 Page 9 of 20

10 Cooling valve actuator =Ok Run down timer = ok Filters very dirty. Static pressure is very low and air volumes not being achieved due to dirty filters. Pipe sensors = Ok Variable speed drive operation= ok Field diffusers don t appear to be functional as current being drawn is too low.(red phase=0 amps White=0 Blue =0) Return air temperature sensor=ok Supply air temperature sensor=ok Unit 02 Cooling valve actuator =Ok Run down timer = ok Filters very dirty. Static pressure is very low and air volumes not being achieved due to dirty filters. Pipe sensors = Ok Variable speed drive operation= ok Field diffusers don t appear to be functional as current being drawn is too low.(red phase=7 amps White=0 Blue =10) Return air temperature sensor=ok Supply air temperature sensor=ok Third Floor Air Handling Units Unit 01 Cooling valve actuator =Ok Run down timer = ok Filters very dirty. Static pressure is very low and air volumes not being achieved due to dirty filters. Pipe sensors = Ok Variable speed drive operation= ok Page 10 of 20

11 Field diffusers don t appear to be functional as current being drawn is too low.(red phase=0 amps White=0 Blue =0) Return air temperature sensor=ok Supply air temperature sensor=ok Unit 02 Cooling valve actuator =Ok Run down timer = ok Filters very dirty. Static pressure is very low and air volumes not being achieved due to dirty filters. Pipe sensors = Ok Variable speed drive operation= ok Field diffusers don t appear to be functional as current being drawn is too low.(red phase=0 amps White=4 Blue =0) Return air temperature sensor=ok Supply air temperature sensor=ok Floor Diffusers (Re-heaters) Within all the floors that were checked, all the areas were very cold. The re-heaters (Diffusers) are not functional and a specified supplier technician needs to investigate the Rikard Diffusers for operation.(please note that programming/ power supplies and heater elements need to be checked for operation.) As I have noted diffusers within certain plant room are lying loose, I would recommend that the air balancing be redone.(please note that this task will need to be done with an Air.conditioning company as the flow meters and instruments used for this task are normally held by them including expertise) The last issue mentioned is of critical importance to maintain the required room temperatures as the floor units do not have heaters within them. Reheat is done purely from the diffusers and these when functional will allow for a more comfortable environment. A realistic temperature set point within the floors needs to be maintained as setting the room thermostats to extremes to not conducive to a stable environment. Page 11 of 20

12 Chiller system Chiller system run request (Logic) has been made to work in line with outside air temperatures. (These were previously only time based) Full maintenance of chillers X 2 4 Broad-Based Black Economic Empowerment [B-BBEE] CEF (SOC) Ltd fully endorses and supports the Government s Broad-Based Black Economic Empowerment Programme and it would therefore prefer to do business with local business enterprises who share these same values. CEF (SOC) Ltd will accordingly allow a preference to companies who provide a valid B-BBEE Verification Certificate. All procurement transactions will be evaluated accordingly. 4.1 B-BBEE Scorecard and Rating As prescribed in terms of the Preferential Procurement Policy Framework Act (PPPFA), Act 5 of 2000 and its Regulations, Tenderers are to note that the following preference point systems are applicable to all Tenders: the 80/20 system for requirements with a Rand value of up to R1,000,000 (all applicable taxes included); and the 90/10 system for requirements with a Rand value above R1,000,000 (all applicable taxes included). Tenderers are to note that if the 80/20 preference point system is stipulated in this RFQ and all Tenders received exceed R1,000,000.00, the RFQ must be cancelled. Similarly, if the 90/10 preference point system is stipulated in this RFQ and all Tenders received are equal to or below R1,000,000.00, the RFQ must be cancelled. The value of this Tender is estimated to be below R1,000,000 (all applicable taxes included) ; and therefore the 80/20 system shall be applicable. When CEF (SOC) Ltd invites prospective suppliers to submit Quotations for its various expenditure plans, it requires Tenderers to have their B-BBEE status verified in compliance with the Codes of Good Practice issued in terms of the Broad Based Black Economic Empowerment Act No. 53 of Page 12 of 20

13 The Department of Trade and Industry recently revised the Codes of Good Practice on 11 October 2013 [Government Gazette No ]. The Revised Codes will replace the Black Economic Empowerment Codes of Good Practice issued on 9 February The Revised Codes provide for a one year transitional period starting 11 October During the transitional period, companies may elect to be measured in terms of the Revised Codes or the 2007 version of the Codes. After the first year of the implementation of the Revised Codes, B-BBEE compliance will be measured in terms of the Revised Codes without any discretion. Companies which are governed by Sector-specific Codes will be measured in terms of those Sector Codes. As such, CEF (SOC) Ltd will accept B-BBEE certificates issued based on the Revised Codes. CEF (SOC) Ltd will also continue to accept B-BBEE certificates issued in terms of the 2007 version of the Codes provided it was issued before 10 October Thereafter, CEF (SOC) Ltd will only accept B-BBEE certificates issued based on the Revised Codes. Tenderers are required to complete Annexure A [the B-BBEE Preference Point Claim Form] and submit it together with proof of their B-BBEE Status as stipulated in the Claim Form in order to obtain preference points for their B-BBEE status. Note: Failure to submit a valid B-BBEE certificate or a certified copy thereof at the Closing Date of this RFQ will result in a score of zero being allocated for B-BBEE. 5 Communication a) Tenderers are warned that a Submission will be liable for disqualification should any attempt be made by a Tenderer either directly or indirectly to canvass any officer(s) or employee of CEF (SOC) Ltd in respect of this RFQ between the closing date and the date of the award of the business. b) A Tenderer may, however, before the closing date and time, direct any written enquiries relating to the RFQ to the following CEF (SOC) Ltd employee: Name: Nthabiseng Mashao nthabisengm@cefgroup.co.za c) Tenderers may also, at any time after the closing date of the RFQ, communicate with the Procurement Department on any matter relating to its RFQ Submission. Page 13 of 20

14 6 Tax Clearance The Tenderer s original and valid Tax Clearance Certificate must accompany the Quotation. Note that no business shall be awarded to any Tenderer whose tax matters have not been declared by SARS to be in order. 7 VAT Registration The valid VAT registration number must be stated here: [if applicable]. 8 Legal Compliance The successful Tenderer shall be in full and complete compliance with any and all applicable national and local laws and regulations. 9 Changes to Quotations Changes by the Tenderer to its submission will not be considered after the closing date and time. 10 Pricing All prices must be quoted in South African Rand on a fixed price basis, including VAT. 11 Prices Subject to Confirmation Prices quoted which are subject to confirmation will not be considered. 12 Negotiations CEF (SOC) Ltd reserves the right to undertake post-tender negotiations with selected Tenderers or any number of short-listed Tenderers. 13 Binding Offer Any Quotation furnished pursuant to this Request shall be deemed to be an offer. Any exceptions to this statement must be clearly and specifically indicated. 14 Repudiations CEF (SOC) Ltd is not committed to any course of action as a result of its issuance of this RFQ and/or its receipt of a Quotation in Submission to it. Please note that CEF (SOC) Ltd reserves the right to: modify the RFQ s goods / service(s) and request Tenderers to re-tender on any changes; Page 14 of 20

15 reject any Quotation which does not conform to instructions and specifications which are detailed herein; disqualify Quotations submitted after the stated submission deadline; not necessarily accept the lowest priced Quotation; reject all Quotations, if it so decides; place an order in connection with this Quotation at any time after the RFQ s closing date; award only a portion of the proposed goods / service/s which are reflected in the scope of this RFQ; split the award of the order/s between more than one Supplier/Service Provider; or make no award at all. CEF (SOC) Ltd reserves the right to award business to the highest scoring Tenderer/s unless objective criteria justify the award to another Tenderer. 15 Evaluation Criteria CEF (SOC) Ltd will utilise the following criteria [not necessarily in this order] in choosing a Supplier/Service Provider, if so required: Criterion/Criteria Explanation Administrative responsiveness Final weighted evaluation based on 80/20 preference point system as indicated in paragraph Error! Reference source not found. Completeness of Submission and returnable documents Pricing and price basis [firm] - whilst not the sole factor for consideration, competitive pricing and overall level of unconditional discounts will be critical B-BBEE status of company - Preference points will be awarded to a Tenderer for attaining the B-BBEE status level of contribution in accordance with the table indicated in Annexure A. 16 Validity Period CEF (SOC) Ltd desires a validity period of 30 [thirty] days from the closing date of this RFQ. Page 15 of 20

16 This RFQ is valid until provide a date. 17 Banking Details BANK: BRANCH NAME / CODE: ACCOUNT HOLDER: ACCOUNT NUMBER: 18 Company Registration Registration number of company / C.C. Registered name of company / C.C. 19 Returnable Documents Returnable Documents means all the documents, Parts and Annexures, as listed in the tables below. a) Tenderers are required to submit with their Quotations the mandatory Returnable Documents, as detailed below. Failure to provide all these Returnable Documents at the Closing Date and time of this RFQ will result in a Tenderer s disqualification. Tenderers are therefore urged to ensure that all these Documents are returned with their Quotations. Please confirm submission of these mandatory Returnable Documents by so indicating [Yes or No] in the table below: Essential Returnable Documents Submitted [Yes or No] Original valid Tax Clearance Certificate [Consortia / Joint Ventures must submit a separate Tax Clearance Certificate for each party] Page 16 of 20

17 Essential Returnable Documents Submitted [Yes or No] ANNEXURE A B-BBEE Preference Points Claim Form ANNEXURE B - Declaration of Interest ANNEXURE C Declaration of Bidder s Past Supply Chain Management Practices ANNEXURE D Certificate of Independent Bid Determination B-BBEE Certificate Page 17 of 20

18 Part 2 QUOTATION FORM DELETE GOODS AND LEAVE SERVICES EVERYWHERE ON THIS PART I/We hereby offer to supply the goods/services at the prices quoted in the Price Schedule below, in accordance with the conditions related thereto. DELETE I/We accept that unless CEF (SOC) Ltd should otherwise decide and so inform me/us, this Quotation [and, if any, its covering letter and any subsequent exchange of correspondence], together with CEF (SOC) Ltd s acceptance thereof shall constitute a binding contract between CEF (SOC) Ltd and me/us. I/We further agree that if, after I/we have been notified of the acceptance of my/our Quotation, I/we fail to deliver the said goods/service/s within the delivery lead-time quoted, CEF (SOC) Ltd may, without prejudice to any other legal remedy which it may have, cancel the order and recover from me/us any expenses incurred by CEF (SOC) Ltd in calling for Quotations afresh and/or having to accept any less favourable offer. Price Schedule I/We quote as follows for the goods required, on a delivered nominated destination basis, including VAT: PROVIDE QUANTITY Item No Description of Goods Unit of Measure Quantity Unit Price (ZAR) Total Price (ZAR) 1 Ciat Air Cooled Chillers 2 2 Chilled Water Pumps 1 3 Air Handling Units 1 4 Fans ( Extract) 1 5 Fan Coil Units 6 Ducting 1 6 Diffusers 1 7 Split Units 1 8 AC Distribution Boards 1 Total Page 18 of 20

19 Delivery Lead-Time from date of purchase order: [days/weeks] Notes to Pricing: a) All Prices must be quoted in South African Rand, inclusive of VAT b) To facilitate like-for-like comparison Tenderers must submit pricing strictly in accordance with this price schedule and not utilise a different format. Deviation from this pricing schedule could result in a Tender being disqualified. c) Please note that should you have offered a discounted price(s), CEF (SOC) Ltd will only consider such price discount(s) in the final evaluation stage if offered on an unconditional basis. SIGNED at on this day of 20 SIGNATURE OF TENDERER S AUTHORISED REPRESENTATIVE NAME: DESIGNATION: REGISTERED NAME OF COMPANY: PHYSICAL ADDRESS: Page 19 of 20

20 Tenderer s contact person: [Please complete] Name : Designation : Telephone : Cell Phone : Facsimile : Website : Page 20 of 20

INVITATION TO BID SUPPLY OF VARIOUS PORTABLE FIRE EXTINGUISHERS

INVITATION TO BID SUPPLY OF VARIOUS PORTABLE FIRE EXTINGUISHERS ASIAN DEVELOPMENT BANK 6 ADB Avenue, Mandaluyong City 550 Metro Manila, Philippines Tel: 632-4298; Fax: 636-2577 or 63-6899 Email: malbano@adb.org and sdiano@adb.org INVITATION TO BID SUPPLY OF VARIOUS

More information

City of Johannesburg Supply Chain Management Unit

City of Johannesburg Supply Chain Management Unit REQUEST FOR QUOTATION FOR GOODS AND SERVICES FOR THE CITY OF JOHANNESBURG Procurement Less than R 00 000 (Including Vat) (For publication on the City of Johannesburg Notice Board/s & Website) The City

More information

"This is only the scope of work for the project. For more information, interested parties should contact Procurement at

This is only the scope of work for the project. For more information, interested parties should contact Procurement at "This is only the scope of work for the project. For more information, interested parties should contact Procurement at purchasing@stpgov.org to ensure receipt of a full bid package, to be listed as a

More information

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S. CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S. NAME OF TENDER: CONSTRUCT, DELIVER AND COMMISSION 3 (THREE) LIFT STATION ELECTRICAL LOCATION OF WORK: 3 Separate work sites in

More information

"This is only the scope of work for the project. For more information, interested parties should contact Procurement at

This is only the scope of work for the project. For more information, interested parties should contact Procurement at "This is only the scope of work for the project. For more information, interested parties should contact Procurement at purchasing@stpgov.org to ensure receipt of a full bid package, to be listed as a

More information

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision...

PART 3-O REQUIREMENTS FOR SPRINKLER SYSTEMS MAINTENANCE AND SUPERVISION. 3-O Introduction O.1 Scope of Maintenance and Supervision... CONTENTS Schedule of amendments for this part of the scheme document Page 1 of 14 3-O Introduction...3 3-O.1 Scope of Maintenance and Supervision...3 3-O.2 Certification conditions...5 3-O.3 LPS 1233 Service

More information

CORRIGENDUM NO: 2 TO REQUEST FOR QUOTATION CRFQ NO E-Tender Ref. No: 9093

CORRIGENDUM NO: 2 TO REQUEST FOR QUOTATION CRFQ NO E-Tender Ref. No: 9093 CPO (REFINERIES) DESIGN, ENGINEERING, SUPPLY, INSTALLATION, TESTING, COMMISSIONING AND POST WARRANTY AMC OF RIM SEAL FIRE PROTECTION SYSTEM FOR BPCL-MUMBAI REFINERY (BPC CL MR) CORRIGENDUM NO: 2 TO REQUEST

More information

Invitation to Bid WATER HEATER HHS & WHH

Invitation to Bid WATER HEATER HHS & WHH Invitation to Bid WATER HEATER HHS & WHH Responses to an Invitation to Bid will be received by the Purchasing Supervisor, Sumner County Board of Education, 1500 Airport Road, Gallatin, TN 37066 for WATER

More information

* To be remitted only through DD/Banker Cheque, in favour of Bank of Baroda, payable at Bhopal.

* To be remitted only through DD/Banker Cheque, in favour of Bank of Baroda, payable at Bhopal. Bank of Baroda, MP & Chattisgarh Zone, Bhopal invites sealed Tenders for Supply of New Fire Extinguishers of ISI Mark only & refilling of existing Fire Extinguishers at the Branches in Madhya Pradesh and

More information

STATEMENT OF WORK ELECTRICAL REPAIR / MAINTENANCE BUILDING PROJECT FDC RACCOON CREEK STATE PARK (BEAVER COUNTY)

STATEMENT OF WORK ELECTRICAL REPAIR / MAINTENANCE BUILDING PROJECT FDC RACCOON CREEK STATE PARK (BEAVER COUNTY) STATEMENT OF WORK ELECTRICAL REPAIR / MAINTENANCE BUILDING PROJECT FDC-213-100797 RACCOON CREEK STATE PARK (BEAVER COUNTY) I. SCOPE OF WORK: The Commonwealth of Pennsylvania, Department of Conservation

More information

Request for quotation (RFQ) for goods/services

Request for quotation (RFQ) for goods/services Request for quotation (RFQ) for goods/services Firefighting equipment s and alarm system for UNICEF Warehouse Khartoum - Soba RFQ No: SDPC/89588/SERVICES/RFQ-135 Request for quotation (RFQ) for (Firefighting

More information

BANK OF BARODA BIHAR REGIONAL OFFICE, 4 TH FLOOR, ANAND VIHAR, West Boring Canal Road, Patna TENDER NOTICE

BANK OF BARODA BIHAR REGIONAL OFFICE, 4 TH FLOOR, ANAND VIHAR, West Boring Canal Road, Patna TENDER NOTICE BANK OF BARODA BIHAR REGIONAL OFFICE, 4 TH FLOOR, ANAND VIHAR, West Boring Canal Road, Patna 800001. TENDER NOTICE NAME OF WORK : Supply of New Fire Extinguishers of ISI Mark (As and when required) & refilling

More information

इ ड यन ओव रस ज ब क Indian Overseas Bank. क ष त र य क य ऱय, Regional Office, Chandigarh

इ ड यन ओव रस ज ब क Indian Overseas Bank. क ष त र य क य ऱय, Regional Office, Chandigarh इ ड यन ओव रस ज ब क स रक ष ववभ ग Security Department क ष त र य क य ऱय, Regional Office, Chandigarh TERMS & CONDITIONS FOR ANNUAL MAINTENANCE SERVICE FOR REFILLING OF ALREADY INSTALLED FIRE EXTINGUISHERS

More information

BID PROPOSAL-REVISED

BID PROPOSAL-REVISED BID PROPOSAL-REVISED PROJECT: B17-13, Bldg 1300 HVAC ( the Work ) CABRILLO COMMUNITY COLLEGE DISTRICT Bidder Name Bidder Representative(s) Bidder Representative(s) Contact Information Bidder Mailing Address

More information

Date of Start and downloading the tender 12 sep 2018

Date of Start and downloading the tender 12 sep 2018 INDRAPRASTHA INSTITUTE OF INFORMATION TECHNOLOGY-DELHI (IIIT-DELHI) Okhla Industrial Estate, Phase III New Delhi 110020 (Tel No 011-26907400, Website: www.iiitd.ac.in) Notice Inviting Tender for Non Comprehensive

More information

BANK OF BARODA ZONAL OFFICE, MP & CG ZONE BHOPAL TENDER NOTICE

BANK OF BARODA ZONAL OFFICE, MP & CG ZONE BHOPAL TENDER NOTICE BANK OF BARODA ZONAL OFFICE, MP & CG ZONE BHOPAL TENDER NOTICE NAME OF WORK : Supply of New Fire Extinguishers of ISI Mark (As and when required) & refilling of existing Fire Extinguishers at the Branches

More information

Terms of Reference for the appointment of a Public Relations Service Provider for events at the Kirstenbosch National Botanical Garden (KNBG),

Terms of Reference for the appointment of a Public Relations Service Provider for events at the Kirstenbosch National Botanical Garden (KNBG), Terms of Reference for the appointment of a Public Relations Service Provider for events at the Kirstenbosch National Botanical Garden (KNBG), Newlands, Cape Town For a period of five (5) years 1 TABLE

More information

ROSWELL INDEPENDENT SCHOOL DISTRICT P.O. Box 1437 Roswell, New Mexico General Bid Conditions

ROSWELL INDEPENDENT SCHOOL DISTRICT P.O. Box 1437 Roswell, New Mexico General Bid Conditions ROSWELL INDEPENDENT SCHOOL DISTRICT P.O. Box 1437 Roswell, New Mexico 88202-1437 General Bid Conditions BID # 19-06 Fire Sprinkler Systems Inspections, Testing and Maintenance SEALED BIDS will be opened

More information

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 GENERAL 1.01 SECTION INCLUDES SECTION 23 0593 TESTING, ADJUSTING, AND A. Testing, adjustment, and balancing of air systems. B. Testing, adjustment, and balancing of hydronic, steam, and refrigerating

More information

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT An ISO 9001 Company Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirapalli 620014, TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT ENQUIRY NOTICE INVITING TENDER Phone:

More information

Relationship beyond banking

Relationship beyond banking Relationship beyond banking Zonal office, Agra Zone Jeevan Prakash, 1st. Floor, LIC Building, Sanjay Place, Agra 282 002 Phone : 0562-2521642 Email: Agra.God@bankofindia.co.in COST OF TENDER : Rs. 500/-

More information

The products covered by the Regulation can be classified as follows:

The products covered by the Regulation can be classified as follows: Table of Contents 1. Purpose of the guidelines and disclaimer... 3 1.1. The Regulation... 3 2. Scope... 3 3. Product environmental impacts... 4 4. State of play of legislation... 4 4.1. History of the

More information

PRE-QUALIFICATION OF FIRE SAFETY AUDITORS

PRE-QUALIFICATION OF FIRE SAFETY AUDITORS STATE BANK OF INDIA LOCAL HEAD OFFICE, BHUBANESWAR PRE-QUALIFICATION OF FIRE SAFETY AUDITORS State Bank of India, Local Head Office, Bhubaneswar invites Expression of Interest (EOI) for conduct of fire

More information

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS SECTION 236200 - PACKAGED COMPRESSOR AND CONDENSER UNITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions apply

More information

Request For Quotations. For The. Fire Sprinkler Retrofit Program For Licensed Small Or Rural Retirement Homes. October 11, 2017

Request For Quotations. For The. Fire Sprinkler Retrofit Program For Licensed Small Or Rural Retirement Homes. October 11, 2017 Request For Quotations For The Fire Sprinkler Retrofit Program For Licensed Small Or Rural Retirement Homes October 11, 2017 1 Table of Contents Introduction... 3 Retirement Home Information... 3 RFQ Overview...

More information

SPECIFICATIONS FOR TENDER # SUPPLY OF DUCTLESS MINI-SPLIT AIR CONDITIONING SYSTEMS FOR WESTERN HEALTH

SPECIFICATIONS FOR TENDER # SUPPLY OF DUCTLESS MINI-SPLIT AIR CONDITIONING SYSTEMS FOR WESTERN HEALTH SPECIFICATIONS FOR TENDER #0171-1250 SUPPLY OF DUCTLESS MINI-SPLIT AIR CONDITIONING SYSTEMS FOR WESTERN HEALTH CLOSING DATE: 29 October 2012 CLOSING TIME: 11:00 AM (Newfoundland Time) Invitation to Tender

More information

Contact Phone Number: (609) Fax: (609)

Contact Phone Number: (609) Fax: (609) Quote Name: Landscaping Description: SEE BELOW FOR FURTHER INFORMATION Township Contact: Andy Baran Contact Phone Number: (609) 361-6672 Fax: (609) 361-7624 Quote Number: Q16-21 Posted Date: April 4, 2016

More information

The following are the terms and conditions for the firms for submission of bids:

The following are the terms and conditions for the firms for submission of bids: To, As per list enclosed, No.D-13011/1/2016-Genl. Government of India Ministry of Textiles ****** Udyog Bhawan, New Delhi, dated March, 2016 Subject: Annual Maintenance Contract for repair/maintenance

More information

Supply & Installation of Fire Protection System at STPI- Nashik. Tender No. STPI/P/PUR/07/14-15 Date Signature of Bidder

Supply & Installation of Fire Protection System at STPI- Nashik. Tender No. STPI/P/PUR/07/14-15 Date Signature of Bidder Software Technology Parks of India - Pune (An Autonomous Society under Govt. of India, Ministry of Communications & Information Technology, Department of Electronics and Information Technology), Plot no.p-1,

More information

Sidney, Ohio 1204 FORMAL ISSUANCE OF CERTIFICATE OF SUBSTANTIAL COMPLETION... ON OR BEFORE JULY 30, 2015.

Sidney, Ohio 1204 FORMAL ISSUANCE OF CERTIFICATE OF SUBSTANTIAL COMPLETION... ON OR BEFORE JULY 30, 2015. SECTION 000050 - INVITATION AND NOTICE TO BIDDERS PROJECT: OWNER: 3003 Cisco Road Sidney, Ohio 45365 Ohio Presbyterian Retirement Services 1001 Kingsmill Parkway Columbus, Ohio 43229 ARCHITECT: 4685 Larwell

More information

Preventative Maintenance Tables

Preventative Maintenance Tables Preventative Maintenance Tables Table of Contents I. Table : Gas Fired Domestic Hot Water Heater II. III. IV. Table : Circulating Pump Table : Convectors Table 4: Grille and Diffusors V. Table 5: Unit

More information

SUWANNEE RIVER WATER MANAGEMENT DISTRICT REQUEST FOR BID NO. 15/16-003AO FIRE ALARM SYSTEM INSTALLATION AND MONITORING.

SUWANNEE RIVER WATER MANAGEMENT DISTRICT REQUEST FOR BID NO. 15/16-003AO FIRE ALARM SYSTEM INSTALLATION AND MONITORING. SUWANNEE RIVER WATER MANAGEMENT DISTRICT REQUEST FOR BID NO. 15/16-003AO FIRE ALARM SYSTEM INSTALLATION AND MONITORING Table of Contents Section Title Page 1 Introduction 2 2 Proposed Schedule 2 3 Instructions

More information

Indian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi , Ph. No.

Indian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi , Ph. No. Indian National Trust for Art and Cultural Heritage (INTACH, 71, KK Birla Lane, Lodhi Estate, New Delhi -110003, Ph. No. 011-49854100 TENDER NOTICE Sealed tender in two separate bids a) Technical bids,

More information

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY ("Official Gazette of RS, issue No. 13/2010) I INTRODUCTION Scope Article 1 This Rulebook stipulates the essential requirements that shall be met with regard to

More information

MUNICIPALITY OF GREENSTONE BOX 70, 1800 Main Street Geraldton, Ontario P0T 1M0 Telephone Facsimile

MUNICIPALITY OF GREENSTONE BOX 70, 1800 Main Street Geraldton, Ontario P0T 1M0 Telephone Facsimile MUNICIPALITY OF GREENSTONE BOX 70, 1800 Main Street Geraldton, Ontario P0T 1M0 Telephone 807-854-1100 Facsimile 807-854-1150 PUBLIC SERVICES DEPARTMENT TENDER NO. PS-2016-2 INSPECTION OF FIRE ALARM SYSTEMS

More information

TESTING, ADJUSTING AND BALANCING

TESTING, ADJUSTING AND BALANCING PART 1 GENERAL 1.01 DESCRIPTION A. Work Included: After completion of the work of installation, owner is responsible for procuring an air balancing and testing agency to test and regulate all components

More information

Surna 25-Ton Chiller Operating & Maintenance Manual

Surna 25-Ton Chiller Operating & Maintenance Manual www.surna.com 303.993.5271 Surna 25-Ton Chiller Operating & Maintenance Manual Models: 300F3-3. 300F4-3, 300FW-3 Revised: July 2015 Table of Contents Warranty Information 4 Limited Warranty 4 Limitation

More information

SUPREME COURT OF INDIA ADMN. MATERIAL BRANCH NOTICE INVITING TENDER FOR COMPREHENSIVE ANNUAL MAINTENANCE CONTRACT FOR RE-FILLING OF FIRE EXTINGUISHERS

SUPREME COURT OF INDIA ADMN. MATERIAL BRANCH NOTICE INVITING TENDER FOR COMPREHENSIVE ANNUAL MAINTENANCE CONTRACT FOR RE-FILLING OF FIRE EXTINGUISHERS SUPREME COURT OF INDIA ADMN. MATERIAL BRANCH LAST DATE OF TENDER : 5 th April, 2018 F.NO. 423/F.E./18/SCI(AM) DATED: 15 th March, 2018 NOTICE INVITING TENDER FOR COMPREHENSIVE ANNUAL MAINTENANCE CONTRACT

More information

CxA to Answer this Section

CxA to Answer this Section EXHIBIT 01 91 13-3, SAMPLE Construction checklist items are to be completed as part of initial checkout and subsequent startup, preparatory to Functional testing. This checklist does not take the place

More information

BANK OF BARODA BARODA CORPORATE CENTRE MUMBAI

BANK OF BARODA BARODA CORPORATE CENTRE MUMBAI BANK OF BARODA BARODA CORPORATE CENTRE MUMBAI TENDER NOTICE FOR ANNUAL MAINTENANCE CONTRACT AND REFILLING OF FIRE EXTINGUISHERS AT BANK OF BARODA CORPORATE OFFICE BUILDINGS IN MUMBAI NAME OF WORK: Bank

More information

DTW Master Specification Section EMCS: Start Up, Verification and Commissioning

DTW Master Specification Section EMCS: Start Up, Verification and Commissioning Page 1 of 6 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Related Sections..1 The contractor is to ensure that all related work is co ordinated among all specification sections, as well as between Division 11,

More information

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR TF N 635 Regulation 574_2014: Annex III CPR and Regulation 568_2014: Annex V CPR 30-05-2014 28.5.2014 L 159/41 REGULATIONS COMMISSION DELEGATED REGULATION (EU) No 574/2014 of 21 February 2014 amending

More information

APPROVED PANEL OF SWITCHBOARD MANUFACTURERS FOR THE SUPPLY OF LOW VOLTAGE SWITCHBOARDS

APPROVED PANEL OF SWITCHBOARD MANUFACTURERS FOR THE SUPPLY OF LOW VOLTAGE SWITCHBOARDS Assets Delivery Group Engineering APPROVED PANEL OF SWITCHBOARD MANUFACTURERS FOR THE SUPPLY OF LOW VOLTAGE SWITCHBOARDS DETAILS SUMMARY VERSION 1 REVISION 5 NOVEMBER 2017 REVISION STATUS The revision

More information

Official Journal of the European Union. (Non-legislative acts) REGULATIONS

Official Journal of the European Union. (Non-legislative acts) REGULATIONS L 146/1 II (Non-legislative acts) REGULATIONS COMMISSION IMPLEMENTING REGULATION (EU) 2016/879 of 2 June 2016 establishing, pursuant to Regulation (EU) No 517/2014 of the European Parliament and of the

More information

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION SECTION 15990 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION The purpose of this guide specification is to assist the Specifier in correctly specifying Mechanical System Testing Adjusting

More information

1.1 DESCRIPTION A. The purpose of this section is to specify Division 23 responsibilities in the commissioning (Cx) process.

1.1 DESCRIPTION A. The purpose of this section is to specify Division 23 responsibilities in the commissioning (Cx) process. SECTION 239950 MECHANICAL COMMISSIONING SYSTEMS PART 1 - GENERAL 1.1 DESCRIPTION A. The purpose of this section is to specify Division 23 responsibilities in the commissioning (Cx) process. B. Commissioning

More information

Variable Speed Drives: Reducing the energy costs of commercial HVAC systems

Variable Speed Drives: Reducing the energy costs of commercial HVAC systems Variable Speed Drives: Reducing the energy costs of commercial HVAC systems Factsheet Using Variable Speed Drives (VSDs) to reduce the cost of heating, ventilation and air conditioning (HVAC) systems in

More information

ALABAMA Propane Gas Association

ALABAMA Propane Gas Association 2018-2019 ALABAMA SAFE APPLIANCE INSTALLATION PROGRAM GUIDELINES This program is available on purchases on or after October 1, 2018 until September 30, 2019 or funds are depleted, whichever comes first.

More information

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE EXTINGUISHERS TABLE OF CONTENTS

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE EXTINGUISHERS TABLE OF CONTENTS RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER 0780-02-14 FIRE EXTINGUISHERS TABLE OF CONTENTS 0780-02-14-.01 Definitions 0780-02-14-.09 Restrictions 0780-02-14-.02 Standards

More information

TENDER NOTICE FOR RATE CONTRACT FOR SUPPLY, INSTALLATION AND REFILLING OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS

TENDER NOTICE FOR RATE CONTRACT FOR SUPPLY, INSTALLATION AND REFILLING OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS TENDER NOTICE FOR RATE CONTRACT FOR SUPPLY, INSTALLATION AND REFILLING OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS Bank of Baroda Zonal Office, Northern Zone, Bank of Baroda

More information

ADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT. February 29, NO CHANGE: March 8, 2012 / NOT LATER THAN 2:00 PM

ADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT. February 29, NO CHANGE: March 8, 2012 / NOT LATER THAN 2:00 PM ADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT February 29, 2012 RFP NO: 17 PROJECT: Josephine County Justice Center HVAC Upgrades BID CLOSING DATE: NO CHANGE: March 8, 2012 / NOT LATER

More information

TENDER NOTICE FOR SUPPLY, INSTALLATION AND MAINTENANCE OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS

TENDER NOTICE FOR SUPPLY, INSTALLATION AND MAINTENANCE OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS TENDER NOTICE FOR SUPPLY, INSTALLATION AND MAINTENANCE OF FIRE EXTINGUISHERS AT BRANCHES / OFFICES IN NCR AND ADJOINING AREAS Bank of Baroda Zonal Office, Northern Zone, Bank of Baroda Building, 6 th Floor,

More information

Installation and Operations Manual

Installation and Operations Manual Installation and Operations Manual H-IM-LLC February 2018 Part No. 25092501 Replaces H-IM-LLC (01/2014) Lead Lag Control System Table of Contents General Safety Information 2 Inspection 2 Warranty Statement

More information

DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID. NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008)

DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID. NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008) STAATSKOERANT, 19 NOVEMBER 2010 No.33763 11 No. R. 1072 DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID 19 November 2010 NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5

More information

INVITATION TO QUOTE. Page 1 of 7. Fire & Emergency Safety Plan Control Number: 2018-CFS-003 Issue Date: March 7, Purpose

INVITATION TO QUOTE. Page 1 of 7. Fire & Emergency Safety Plan Control Number: 2018-CFS-003 Issue Date: March 7, Purpose INVITATION TO QUOTE Title: Fire & Emergency Safety Plan Control Number: 2018-CFS-003 Issue Date: March 7, 2018 Purpose The District of Sparwood (Sparwood) invites interested parties (Respondents) to submit

More information

EMPANELMENT DOCUMENT NOTICE FOR EMPANELMENT OF SUPPLIERS AND SERVICE PROVIDERS.

EMPANELMENT DOCUMENT NOTICE FOR EMPANELMENT OF SUPPLIERS AND SERVICE PROVIDERS. PREMISES AND ESTATE SECTION CIRCLE OFFICE, GUWAHATI, 1 ST FLOOR, DWARKAPURI,SONI RAM BORA ROAD, BORA SERVICE, GUWAHATI-781007 Tel Ph: Direct: 0361-2466820 Fax : 0361-2466816 Email Id: pecoguw@canarabank.com

More information

SPECIFICATIONS FOR TENDER # SUPPLY OF A FIRE ALARM SYSTEMS SERVICE AGREEMENT FOR WESTERN HEALTH

SPECIFICATIONS FOR TENDER # SUPPLY OF A FIRE ALARM SYSTEMS SERVICE AGREEMENT FOR WESTERN HEALTH SPECIFICATIONS FOR TENDER #0371-0739 SUPPLY OF A FIRE ALARM SYSTEMS SERVICE AGREEMENT FOR WESTERN HEALTH CLOSING DATE: 8 June 2007 CLOSING TIME: 11:00 AM (Newfoundland Time) Invitation to Tender for a

More information

FISHER & PAYKEL HEALTHCARE CORPORATION LIMITED

FISHER & PAYKEL HEALTHCARE CORPORATION LIMITED DIVIDEND REINVESTMENT PLAN OFFER DOCUMENT 2015 1. Introduction This document (Offer Document) contains the terms and conditions of the Fisher & Paykel Healthcare Corporation Limited (Fisher & Paykel Healthcare)

More information

SECTION ROTARY-SCREW WATER CHILLERS

SECTION ROTARY-SCREW WATER CHILLERS PART 1 GENERAL 1.01 SECTION INCLUDES A. Factory-assembled packaged chiller. B. Charge of refrigerant and oil. C. Controls and control connections. D. Chilled water connections. E. Electrical power connections.

More information

Florida Department of Transportation

Florida Department of Transportation Page 1 of 7 RICK SCOTT GOVERNOR Florida Department of Transportation 1109 S. Marion Avenue Lake City, Florida 32025 ANANTH PRASAD SECRETARY September 27, 2011 To: Proposal Holders Addendum No: 1, E2Q23,

More information

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance...

Table of Contents. Forward Quality Policy Design Parameters Section A Unit Operation Section B Unit Maintenance... Table of Contents Forward... 3 Quality Policy... 3 Design Parameters... 4 Section A Unit Operation... 5 Section B Unit Maintenance... 6 Trouble Shooting Guide... 6 Wiring Diagram... 7 Section C Unit Installation...

More information

Massachusetts COOL SMART

Massachusetts COOL SMART Massachusetts COOL SMART 2015 RESIDENTIAL DUCTLESS MINI-SPLIT HEAT PUMP Rebate Application Ductless Mini-Split Heat Pump REBATE COOL SMART is offering residential customers of program sponsors up to a

More information

NOTICE INVITING TENDER

NOTICE INVITING TENDER NOTICE INVITING TENDER Ref No.: SCOPEMINAR/MMO/18-19/183 Dated :- 06.12.2018 1. Online e-tenders are invited by Dy.General Manager, SCOPE on behalf of Constituents of SCOPE MINAR, Laxmi Nagar Delhi- 110092

More information

Department of Biochemistry University of Lucknow Lucknow

Department of Biochemistry University of Lucknow Lucknow Department of Biochemistry University of Lucknow Lucknow-226007 TENDER NO.: LU-Biochem COE/001/2017 Dated: September 20, 2017 Short term Tender/Bid invited for Construction/fabrication of an airconditioned

More information

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories. SECTION 238113 - PACKAGED TERMINAL AIR CONDITIONERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Drying Cabinet With Timer

Drying Cabinet With Timer Malmet (Australia) Pty Ltd Head Office & Customer Service 9-11 McKay Avenue PO Box 373 LEETON NSW 2705 Phone: (02) 6953 7677 Email: inquiries@malmet-aus.com.au ABN 95 001 717 791 Operation, Maintenance

More information

TENDER DOCUMENT FOR SUPPLY OF EPOXY MIXING & POURING PLANT

TENDER DOCUMENT FOR SUPPLY OF EPOXY MIXING & POURING PLANT BHARAT HEAVY ELECTRICALS LTD., CORPORATE R&D DIVISION VIKAS NAGAR, HYDERABAD-500093 (INDIA) Enquiry : Date : PURCHASE SECTION TECHNICAL SECTION SPEC.NO. 91 40 2377 8474 PHONE 91 40 2377 4494 Ext.7326 ST:ICH:08:001

More information

ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL

ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL ELECTRIC AIR HEATER INSTALLATION AND SERVICE MANUAL BC(E) SERIES INDOOR / OUTDOOR MANUFACTURED BY GENERAL INFORMATION PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: TELEPHONE: INSTALLATION

More information

Ceiling Sweep Fan Assembly Instructions

Ceiling Sweep Fan Assembly Instructions Ceiling Sweep Fan Assembly Instructions CSF Series Installation Note: This fan must be installed by a licenced electrical contractor Improperly installed ceiling sweep fans can be dangerous and expensive

More information

AHU INSTALLATION & OPERATION MANUAL

AHU INSTALLATION & OPERATION MANUAL AHU INSTALLATION & OPERATION MANUAL VERSION 2 AIR HANDLING UNIT MODELS: AHU 500, AHU 900, AHU 1200, AHU 1700, AHU 2000, AHU 2500, AHU3500, AHU 4500, AHU 5000, AHU 6000, AHU 7000, AHU 8000, AHU 10000, AHU

More information

REQUEST FOR PROPOSALS CLEANING SERVICES

REQUEST FOR PROPOSALS CLEANING SERVICES REQUEST FOR PROPOSALS CLEANING SERVICES Jeffrey Gray City Manager City of Jonesville 265 E. Chicago Street Jonesville, MI 49250 manager@jonesville.org (517) 849-2104 Overview The City of Jonesville is

More information

Purchase: (Fire Fighting) May 26, Sub: Quotation for AMC of Fire Fighting Systems

Purchase: (Fire Fighting) May 26, Sub: Quotation for AMC of Fire Fighting Systems Purchase: 2015-16(Fire Fighting) May 26, 2015 Sub: Quotation for AMC of Fire Fighting Systems Dear Sir, The Institute of Company Secretaries of India is a statutory body set up by an Act of Parliament.

More information

INVITATION FOR QUOTATION. TEQIP-II/2015/RJ1G08/Shopping/25

INVITATION FOR QUOTATION. TEQIP-II/2015/RJ1G08/Shopping/25 INVITATION FOR QUOTATION TEQIP-II/2015/RJ1G08/Shopping/25 04-Aug-2015 To, "firm name and address" Sub: Invitation for Quotations for supply of Goods Dear Sir, 1. You are invited to submit your most competitive

More information

REBATE. Ductless Mini-Split Heat Pump

REBATE. Ductless Mini-Split Heat Pump Ductless REBATE COOL SMART is offering residential customers of program sponsors up to a $500 rebate for purchasing and installing a ductless mini-split heat pump that meets the program s energy efficiency

More information

COMFORT PACK INSTALLATION AND MAINTENANCE INSTRUCTIONS

COMFORT PACK INSTALLATION AND MAINTENANCE INSTRUCTIONS R-410A - C MODELS COMFORT PACK PACKAGED THRU-THE-WALL AIR CONDITIONER WITH ELECTRIC HEAT INSTALLATION AND MAINTENANCE INSTRUCTIONS National Comfort Products 539 Dunksferry Road Bensalem, PA 19020 (215)

More information

Annual Fire Systems and Backflow Preventers Testing

Annual Fire Systems and Backflow Preventers Testing Facilities Management Request for Qualifications Annual Fire Systems and Backflow Preventers Testing At Various Facilities Proposals Due: 2:30 PM, Tuesday May 15, 2018 Deliver to: Attn: Sara Winger, Purchasing

More information

NOTICE TO CONTRACTORS

NOTICE TO CONTRACTORS NOTICE TO CONTRACTORS Notice is hereby given that sealed bids will be received by the City Council of the City of Reedley for furnishing all labor, materials, services, and equipment and performing all

More information

AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND SINGLE-SPLIT

AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND SINGLE-SPLIT SAUDI ARABIAN STANDARD SASO 2663/2017 والجودة الھيئة السعودية للمواصفات والمقاييس Saudi Standards, Metrology and Quality Org (SASO) SASO 2663:2017 (Draft) AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING

More information

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier MANUAL 8/12/05 INSTALLATION, OPERATION & MAINTENANCE Commercial High Efficiency Heat Pipe Dehumidifier Model BKP TM 100 Heat Pipe Technology, Inc. 6904 Parke East Blvd. Tampa FL 33610 Tel: (813) 470-4250

More information

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS TABLE OF CONTENTS I. General Information.................................................. 2 II. Standard Ceiling Plenum

More information

OFFICE OF THE PRINCIPAL GOVERNMENT ENGINEERING COLLEGE JAGDALPUR (C.G.)494005

OFFICE OF THE PRINCIPAL GOVERNMENT ENGINEERING COLLEGE JAGDALPUR (C.G.)494005 OFFICE OF THE PRINCIPAL GOVERNMENT ENGINEERING COLLEGE JAGDALPUR (C.G.) Ph. 07782-229439 Fax-07782-229401, website : www.gecjdp.ac.in Email: principal@gecjdp.ac.in INVITATION FOR QUOTATION TEQIP-II/2014/CG1G02/Shopping/206

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 21 0800 - COMMISSIONING OF FIRE SUPPRESSION SYSTEMS GENERAL 1.1 SUMMARY General 1. Work under this contract shall meet the requirements of Division 01, General Requirements, Conditions of Contract,

More information

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch OPERATION & MAINTENANCE MANUAL IMPORTANT! Read before proceeding! Please read and save these instructions. Read carefully before

More information

Bank of Baroda Zonal Office, Tamil Nadu and Kerala Zone, Baroda Pride, New No.-41, Luz Church Road, Mylapore, Chennai

Bank of Baroda Zonal Office, Tamil Nadu and Kerala Zone, Baroda Pride, New No.-41, Luz Church Road, Mylapore, Chennai TENDER NOTICE FOR SUPPLY, INSTALLATION, REFILLING AND ANNUAL MAINTENANCE OF FIRE EXTINGUISHERS INCLUDING AMC OF EXISTING & OLD SYSTEMS AT DIFFERENT BRANCHES OF BANK OF BARODA OF TAMILNADU & KERALA ZONE

More information

Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety

Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety Protocol between Local Housing Authorities and Fire and Rescue Authorities to improve fire safety Foreword by Communities and Local Government Ministers It is always a priority to ensure safety from the

More information

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS.

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS. THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS. IF YOU RECEIVED A NOTICE BY MAIL AND YOU DO NOT CURRENTLY HAVE A FIRE ALARM INSTALLED IN YOUR BUILDING, YOU MAY DISREGARD THE NOTICE. Dear Building

More information

REQUEST FOR QUOTES (RFQ) # Issue Date: September 21, 2017

REQUEST FOR QUOTES (RFQ) # Issue Date: September 21, 2017 Procurement Division Public Services Building 2051 Kaen Road Oregon City, OR 97045 (503) 742-5444 (Office) REQUEST FOR QUOTES (RFQ) #2017-66 Issue Date: September 21, 2017 Project Name: Quote Due Date/Time:

More information

REQUEST FOR PROPOSALS FOR THE PROVISION OF PREVENTIVE MAINTENANCE ON FACILITY HVAC SYSTEMS FOR SKOKIE PUBLIC LIBRARY

REQUEST FOR PROPOSALS FOR THE PROVISION OF PREVENTIVE MAINTENANCE ON FACILITY HVAC SYSTEMS FOR SKOKIE PUBLIC LIBRARY REQUEST FOR PROPOSALS FOR THE PROVISION OF PREVENTIVE MAINTENANCE ON FACILITY HVAC SYSTEMS FOR SKOKIE PUBLIC LIBRARY Skokie Public Library is requesting proposals for a contract for the provision of preventive

More information

CONTENTS AUTOMATIC TRANSFER SWITCHES

CONTENTS AUTOMATIC TRANSFER SWITCHES CONTENTS AUTOMATIC TRANSFER SWITCHES PART 1 GENERAL 1.1 Related Documents 1.2 Summary 1.3 References 1.4 Quality Assurance 1.5 Submittals 1.6 Delivery, Storage and Handling 1.7 Instructions And Training

More information

Residential Rebate Program Available to NYSEG and RG&E residential natural gas and electric customers.

Residential Rebate Program Available to NYSEG and RG&E residential natural gas and electric customers. Residential Rebate Program Available to NYSEG and RG&E residential natural gas and electric customers. How to Participate: Please use this checklist to mark off each completed step. m Step 1: Equipment

More information

CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT

CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT CONDITIONS OF SERVICE - NBN SERVICES 1. ABOUT These Conditions of Service apply to all NBN Services. These Conditions of Service form part of our Standard Form of Agreement found at www.adam.com.au/legal.

More information

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit January 2008 WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit Installation Operation Maintenance The units are designed for permanent up flow, counter flow, or horizontal left or right airflow

More information

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1 GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per

More information

Time Extension: Tender submission deadline is extended up to 12:00 Hrs. of

Time Extension: Tender submission deadline is extended up to 12:00 Hrs. of ASSAM ELECTRICITY GRID CORPORATION LIMITED OFFICE OF THE MANAGING DIRECTOR Regd. Office: (FIRST FLOOR), BIJULEE BHAWAN, PALTANBAZAR; GUWAHATI - 781001 CIN: U40101AS2003SGC007238 PHONE: 0361-2739520 FAX

More information

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - TF N 530 Rev.2 2012-04-13 CONSTRUCTION SECTOR STANDARDIZATION GUIDANCE DOCUMENT Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - 1 Drafting

More information

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access II User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access Part #2139703 Rev. G II Table of Contents Introduction...3 Elevator Overview...4 Description of Features...5-7

More information

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News VA 23606 Telephone (757) 873-6800 FAX (757) 873-3632 Website: www.ebacusa.com INTRODUCTION

More information

Membership Scanning your card or entering your card number when in store or shopping Online Earning Member Benefits

Membership Scanning your card or entering your card number when in store or shopping Online Earning Member Benefits By registering as a member or claiming any Member Benefit, you agree to be bound by, and your participation in Lowes Rewards will be governed by, these Terms and Conditions. 1. Membership 1. To become

More information

1. Delete BID FORM in its entirety and replace with the BID FORM attached to this Addendum.

1. Delete BID FORM in its entirety and replace with the BID FORM attached to this Addendum. ADDENDUM NO. 2 TO THE BIDDING DOCUMENTS Solicitation Number 2016-13 Fire Alarm, Sprinkler & BFP Inspections and Repairs Saint Clair County MidAmerica Saint Louis Airport DATE: November 30, 2016 BIDS CLOSE:

More information

Operating Performance

Operating Performance INFORMATION SHEET 1 Jackson Engineering Advisers are specialist Building Services Engineers. This information sheet is offered as an aid to Building Owners and Managers as a guide to plant life expectancies.

More information