Welcome to Unico! The Small Duct High Velocity (SDHV) System
|
|
- Virgil Jeffrey Howard
- 5 years ago
- Views:
Transcription
1 Welcome to Unico! The Small Duct High Velocity (SDHV) System
2 Advantages to SDHV Uses up to one-third the space of a conventional ducted system No need to drop ceilings, build soffits, etc. Preserves architectural integrity of the structure Takes out 30% more humidity No drafts or streaking of dirt
3 Blower Lagged Water and Fridge Connections AC Module with Primary Drain and Trap HW Module with 3 Port Valve Uni-strut and Support Frame (AV mount to be used) Mixing Box Drain Pan
4
5 Galvanised Ducting Start Collar Transitions from Blower to Plenum Sizes: mm mm mm mm Includes 50mm insulation Wrap
6 Galvanised Ducting Plenum Nested - up to 15m per box Locks together with Reeves Interlocking Joint Requires sealant and aluminium tape on all seams Male/female joints must also be secured with screws/rivets
7 Fibreboard Ducting Start Collar 160x160mm Start Collar for the 160mm sq. and the 200mm sq. fibreboard Ducting 240 x 240mm Start Collar for the 240mm Fibreboard Includes Neoprene Self- Adhesive Sealant Tape
8 Fibreboard Plenum 1218: 160 x 160 mm int. 250 x 100 mm int. 2430: 400 x 100 mm int. 200 x 200 mm int. 3642: 400 x 100 mm int. 200 x 200 mm int. 4860: 240 x 240 mm int. 500 x 100 mm int.
9 Small Space for Ductwork
10 Lower Airflow & 6 Row Coil Removes 30% More Moisture
11 122 F (50 C) Discharge Air Temp At 47 Rating Point
12
13 Geothermal HP Coil Module
14 Hot Water Heating
15 Boiler HW module Hot Water Heating Module Vertical Hot Water Heating Module
16 SDHV Typical Registers Conventional 2 inch outlet 4 x 10 Standard Register 3/4 x 8 inch outlet 16
17
18
19 SDHV vs. Conventional Sized the same way as a conventional system s HVAC load SDHV has a colder coil for greater moisture removal The coil uses deeper and more tightly finned coil 1000 to 2000 fpm in the main trunk
20 Aspiration versus Diffusion Gentle Air Movement Throughout the Room Returns MUST be opposite supply. Dead Zone Return can be anywhere Narrow Band of High Velocity Air Dead Zone Drafts
21 Applications Where is SDHV Used? Residential: Historic, Retrofit, Custom Home Commercial: Universities, Churches, Offices Industrial: Spot Cooling
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43 What is iseries? An Inverter Heat Pump Can be used for Air Conditioning, Heating, and Domestic Hot Water (DHW) through use of an optional de-superheater A variety of outdoor and indoor units can be matched to the desired configuration + =
44
45 What is iseries? SINGLE SPLIT: One Outdoor Unit and One Indoor Unit MULTISPLIT: One Outdoor Unit and up to Four Indoor Units SINGLE SPLIT MULTISPLIT One outdoor unit can be both single split and multi-split Easy installation. Every indoor unit is connected to outdoor unit with a simple flare connection.
46
47 Outdoor Operating Conditions -32 C (-25.6 F) -15 C (5 F) +43 C +50 C (109.4 F) (122 F) iseries systems fit every installation, both warm and cold climate
48 Wide modulation range Larger modulation means less electric consumption and more efficiency
49 Rated A++ Efficiency High Energy Efficiency
50 Additional emix port for Domestic Hot Water
51 Intelligent Defrost and Dynamic Cold Draft 1. No Cold Blow = No Cycle Losses 2. More Efficient, You never stop heating in the Defrost Mode 3. A trickle of hot gas directly from the compressor is used to prevent ice from forming 4. Two Electric Heaters: 1. To keep the crankcase warm 2. To Prevent the Condensate Drain Pan from freezing
52 I Series Range IS30G80 IS36G110 8 KW 11 KW
53 Features that the market leaders in ductless air conditioning and heating do NOT have: Auxiliary or Emergency Heat Lower Temperatures for Heating Operation Better defrost system, can operate when the system is in heating mode Same outdoor unit used for both one to one and multi-split applications
54 Features that the market leaders in ductless air conditioning and heating do NOT have: Ability to do zoning with dampers A variety of third party thermostats Ability to cool or heat multiple rooms Ability to provide Domestic Hot Water
55 Herons Wood, Exmouth
56 Julie Veysey: The Rolls Royce of Air Conditioning systems Herons Wood, Exmouth
57 Holland Park, London 12 Apartments: 2.15M - 7.5M
58 Inn on the Park, Jersey
59 Inn on the Park, Jersey
60 Churches
61 Polish Catholic Mission, London
62 Polish Catholic Mission, London
63 Polish Catholic Mission, London
64 Polish Catholic Mission, London
65 SPOT COOLING
66 Halliburton Maintenance Unit, Algeria
67 Oxo Tower, London
68 Jamie Oliver s Fifteen Cornwall Restaurant
69 Free Design Service 1. Provide us with construction type and R values 2. A dimensional drawing 3. See
70 Sizing and Selection Calculations Develop Model Heat Loads- Wrightsoft Specifications / Requirements Type Heating, Cooling and/or Ventilation Controls Zoning Remote/Smart Controls/ BMS System Select Unit Unit Location and Duct Routes
71 Sizing and Selection Calculations Proprietary Software Wrightsoft Where is the Project? Construction Material Windows, Doors, Skylights Sensible Loads Computers, Lights Latent Loads People Ventilation, air changes
72
73
74
75
76 Material List Divided into Categories All prices at List Price and Subject to Discount
77
Unico Training. Welcome to Unico!
Welcome to Unico! UNICO Inc Who are we? Unico Inc. is a family owned and operated manufacturing company. Unico Inc. is the largest manufacturer of SDHV systems in the world. Unico Inc. is manufactured
More informationUnico Presentation. Abridged iseries
Abridged iseries Combines all the efficiencies and performance of inverter technology with all the features and benefits of The Unico System Argoclima Group is a European leader in HVAC technology and
More informationUnico Presentation. Introducing
Introducing Combines all the efficiencies and performance of inverter technology with all the features and benefits of The Unico System Made in conjunction with Argoclima Group is a European leader in
More informationUnico Training. Class for R E Michel Salesmen
Class for R E Michel Salesmen Outlet (UPC-56B) Sound Attenuator (UPC-26C) Elbow Plenum Supply Tubing (UPC-25) Blower Modules (2430,3642, 4860) Heating Module (MH2430, MH3660) Cooling Modules (MC2430, MC3642,
More informationThe Benefits Really Add Up
Unico, Inc. 7401 Alabama Ave. St. Louis, MO 63111 Unico, Inc. manufacturing plant and sub-assembly plant +1 800 527 0896 +1 314 481 9000 www.unicosystem.com Unico, Inc. is the leader in Small Duct High
More informationDecember 2014 Pints with Pete
December 2014 Pints with Pete The Year In Review Busy Year at Unico New Products VAH: 2 2 ½ Ton, 2 ½ to 3 Tons, 3 to 3 ½ Tons I Series Outdoor Units IS24 IS30 IS36 New Products at Unico I Series Indoor
More informationISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS
ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL
More informationService Step by Step Trouble-Shooting Check-List
WARNING: Only Data Aire trained technician or experience technicians should be working on Data Aire Equipment. Protect yourself at all times and work safe. Date: Dates at the job site: From: to Job#: Serial#:
More informationTechnical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer
Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationSECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION
SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More informationIDL20e (2 way discharge) IDS60e (4 way discharge) Inffusers. UDI (vertical discharge) Frequently Asked Questions
IDL20e (2 way discharge) IDS60e ( way discharge) Frequently Asked Questions UDI (vertical discharge) Inffusers INFFUSER FREQUENTLY ASKED QUESTIONS The following are frequently asked questions (FAQ s) on
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS
036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The
More informationGUIDE SPECIFICATIONS AQUARIUS ii
Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water
More informationChilled Beam/Induction Unit
For the energy efficient buildings of today and tomorrow Chilled Beam/Induction Unit All Way Blow Chilled Beam Technical Specifications American Owned and Operated Chilled Beam/Induction Unit A Chilled
More informationCHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS
550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.
More informationEMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons
560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase
More informationSPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED
(491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationThe Unico System for Eichler Homes: Visionary Indoor Comfort System Complements & Preserves Visionary Design
The Unico System for Eichler Homes: Visionary Indoor Comfort System Complements & Preserves Visionary Design The Vision alifornia Modernists and Eichler aficionados are well-acquainted with Joe Eichler
More informationTechnical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)
Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper
More informationGUIDE SPECIFICATIONS AQUARIUS ii
Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Pump, Ground Water Pump
More informationVertical Air Handler Unit
Bulletin 20-019 (September 2016) Vertical Air Handler Unit For cooling, the unit is designed for R-410A refrigerant (both A/C and Heat Pump) or a chilled water coil. For heating, the unit offers an optional
More informationTechnical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307
DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application
More informationPrecision air handling cabinets Ciatronic MICRO/EXPAIR
/ Reducted footprint Double-wall construction Built-in voltage variator PLC control Variable speed condenser fan ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5 to
More informationInffusers. idl20 (2 WAY) ids60 (4 WAY)
Inffusers idl20 (2 WAY) ids60 (4 WAY) built on innovation what is an inffuser? DADANCO s INFFUSERS are quite simply an induction diffuser that uses special nozzles located in the underside of the air plenum
More informationKIC Air Curtains. Technical Guide
TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The
More informationSpecification Data. General:
Specification Data General: Zone Units (ACU s) will be draw through vertical type having double skin construction. All Zone Units will have all necessary components such as control valves and motors to
More informationPCAH SERIES AIR HANDLER
PCAH SERIES AIR HANDLER PCAH2/PCAH3/PCAH4 OPERATING MANUAL 1 2 3 4 5 6 7 8 9 10 TABLE OF CONTENTS GETTING STARTED... 3 ELECTRICAL CONNECTIONS... 3 2.1 POWER CONNECTIONS... 3 2.1.1 PCAH2/PCAH3... 3 2.1.2
More informationCOMcheck Software Version Review Mechanical Compliance Certificate
COMcheck Software Version 4.0.7.2 Review Mechanical Compliance Certificate Section 1: Project Information Energy Code: 2014 Oregon Energy Efficiency Specialty Code Project Title: Benton County Health Project
More information36,000-62,000 BTUH Nominal Capacity
36,000-62,000 BTUH Nominal Capacity STANDARD EQUIPMENT 2TEE3F62A, 4TEE3F62B VARIABLE SPEED AIR HANDLER Ships horizontal - converts to vertical by standing on end. Six-way convertibility-horizontal (left
More informationDIVISION 15 MECHANICAL
DIVISION 15 MECHANICAL A. GENERAL DESIGN CONDITIONS 1. Design occupied spaces to maintain 72 F and a space dew point temperature not to exceed 55 F. 2. Design classroom and office space buildings with
More informationGTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts
GTIP60 ISO GT Series, Inch Pounds 60 Hz GT010070 (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts Rev: 903 Rev 1 Revisions: 31103 Changed HZ dwg to field convertible 5902 changed Unit
More informationDuctless Series Variable Speed Split Systems
P r e se n t s Ductless Series Variable Speed Split Systems Ductless Series Variable Speed Split Systems 2 EMI E-verter Ductless Split Systems are an excellent alternative for cooling and heating indoor
More information15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING
SOUND REFRIGERANT ENVIRONMENTALLY PAN5 Product Specifications 15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT Environmentally sound R--410A refrigerant
More informationHVAC 101. H V A C S y s t e m s
H V A C 1 0 1 S y s t e m s Introduction & Overview Should you care? Mechanical System Types Components & operation Popular Application Key Issues and Design Considerations System Comparisons First Cost
More informationSECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.
SECTION 15650 REFRIGERATION EQUIPMENT PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories. B. Related Section: 1. 11400
More informationTechnical Development Program
Technical Development Program PRESENTED BY: James Parker Insert your logo here AIR HANDLERS Coils: Direct Expansion Chilled Water and Heating Menu Section 1 Introduction Section 2 Typical Coil Applications
More informationProduct Line Introduction. Karl Zhang Technical support engineer
Product Line Introduction Karl Zhang Technical support engineer Air Conditioning Solutions Heating & Hot Water Solutions Control Solutions Air Conditioning Solutions Residential Application Commercial
More informationRosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS
10 Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS 2 INDEX Page Description - Introduction -Application - Data... 2 Typical Installation... 3 Sound performance... 3-6 Dimensional
More informationGEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion
Close Climate Control for IT Environments GEA Ultra-Denco Reliability with low power consumpstion GEA Heat Exchangers / HVAC Systems Numerical Flow simulation Velocity / Pressure field / Turbulence high
More informationINSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER
ASPEN MANUFACTURING 373 ATASCOCITA RD. HUMBLE, TX 77396 TEL (281) 441-6500 FAX (281) 441-6510 > INSTALLATION INSTRUCTIONS FMB/FMC SERIES MULTI-POSITION AIR HANDLER IMPORTANT: "The
More informationAn HVAC Audit of the Canberra Institute of Technology
An HVAC Audit of the Canberra Institute of Technology 30 th November 2016 Amnon Holland amnon.holland@esbsconsult.com.au www.esbsconsult.com.au Agenda Overview CIT and various other sites The sites Type
More informationAdvance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units
Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium
More informationAIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems
233100 AIR DISTRIBUTION PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 230700 HVAC Insulation B. Section 237300 Air Handling C. Section 230900 Building Automation and Control System Guidelines D. Section
More informationElectric Duct Heaters. IDHB & IDHC Series
Electric Duct Heaters IDHB & IDHC Series May 2014 1 Duct Heaters Greenheck has a complete line of configurable electric duct heaters that are perfectly suited to your HVAC application. Our CAPS configuration
More informationWhat is a High Velocity System?
What is a High Velocity System? What s different? Original concept introduced in 1946 for heat in aircraft High Velocity Systems utilize two or three inch outlets and distribution tubes to deliver the
More informationHAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001
This HAP e-help provides a high-level overview of induction beams, how they work and how to model them in HAP 4.8 (and later versions). The first half of the article explains how induction beams work.
More informationFigure 22-1 Evaporator sensible and latent capacity vs. entering air wet bulb
Figure 22-1 Evaporator sensible and latent capacity vs. entering air wet bulb Figure 22-2 Enthalpy change through the evaporator Figure 22-3 Two aluminum domestic refrigeration evaporators Figure 22-4
More informationCabinet Unit Heaters Steam / Hot Water
11-160.4 February, 2005 Cabinet Unit Heaters Steam / Hot Water Model C MODEL IDENTIFICATION Table of Contents I. Model Identification... 3 Page Il. IIl. III. IV. Design Benefits A. Features and Benefits...
More informationVariCool VAV Engineering Guide
Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control
More informationCOMcheck Software Version Mechanical Compliance Certificate
COMcheck Software Version 3.8.2 Mechanical Compliance Certificate 90.1 (2007) Standard Section 1: Project Information Project Type: New Construction Project Title : Rudy's Star Motors Construction Site:
More informationELECTRICAL QUANTITY WEIGHT (LB)
VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø /
More informationTechnical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS
Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWERS 7-1/2 and 10 NOMINAL TONS LA090 & LA120 DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationNew and Emerging HVAC Technologies. Rod Rhoads, GDS Associates Dave McCullaugh, Mitsubishi Electric Trane HVAC US Dave Binz, Cambridge Engineering
New and Emerging HVAC Technologies Rod Rhoads, GDS Associates Dave McCullaugh, Mitsubishi Electric Trane HVAC US Dave Binz, Cambridge Engineering Rod Rhoads, Leidos Custom for non standard projects» Custom
More informationDXair Pool Dehumidifiers
DXair Pool Dehumidifiers LV Series / to 6 Ton G-60 Galvanized The option-rich DXair LV Series pool dehumidifier has one of the smallest cabinets in the industry, making it a great choice for replacement
More informationSequence of Operations (excerpt)
Sequence of Operations (excerpt) Chilled Water System Consists of one (1) 600 cooling ton Trane CVHE 3 stage centrifugal chiller, with associated chilled water pumps, condenser water pumps and one (1)
More informationHRV-IP. Ceiling Type Heat Pump Heat Recovery Unit
HRV-IP Ceiling Type Heat Pump Heat Recovery Unit HRV-IP Ceiling Type Heat Pump Heat Recovery Unit Ceiling type heat pump heat recovery units are energy saving devices thanks to plate type heat exchanger
More informationCapt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!
Capt. Tim s s Duct Design Mythbusters The bitterness of poor quality is remembered long after the sweetness of low price is forgotten! WHY CARE ABOUT THE DUCTS? Human Comfort Zone (After All, it s s only
More information15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON
7D- -A EVOLUTIONr 15 SEER SINGLE-PACKAGED HEAT PUMP SYSTEM WITH PURONr (R-410A) REFRIGERANT SINGLE PHASE 2-5 NOMINAL TONS (SIZES 24-) Fig. 1 - Unit 7D - -A Product Data A09032 Single-Packaged Products
More informationModular Air Cooled Scroll Chillers
Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube
More informationENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory
Overview of Chilled Beam Technology Purpose Chilled beam technology is new to the United States but has been used in Europe since the 1950 s. Chilled beams can reduce energy costs, improve indoor air quality,
More informationMHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH
MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed
More informationCHAPTER IV AIR DISTRIBUTION AND BALANCE
CHAPTER IV AIR DISTRIBUTION AND BALANCE 4.1. INTRODUCTION When projecting an air-conditioning system, the following steps should be followed: 1) Determine the heat gain or loss 2) Establish the air requirements
More informationCOMMERCIAL HVAC PACKAGED EQUIPMENT. Split Systems
COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics. They are
More informationcomfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps
comfort where it counts Variable Speed Ductless Split Systems Single Zone Air Conditioners / Heat Pumps 2 EMI E-verter Ductless Split Systems are an excellent alternative for cooling and heating indoor
More informationATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL
LINE ITEM # ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL LINE ITEM DETAIL Labor Material FURNACE COMPONENTS 1 Furnish & Install Sight-Impaired Thermostat For Heating and Cooling
More information50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT
50HJQ-11SB 50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION
More informationInstallation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier
RXID-AW90A Whole House Dehumidifier with fresh air ventilation Installation Guide Dehumidification Fresh Air Ventilation Compact Size Energy Efficient The whole house dehumidifier integrates highcapacity
More informationTechnical Data Ducted Three Phase Split System Air Conditioner
ENERGY EFFICIENT ISD / OSA 2 Technical Data Ducted Three Phase Split System Air Conditioner EXTRA LONG LIFE EPOXY COATED OUTDOOR COIL Nominal Cooling Capacity 26.5 kw (Total) JUNE 4 ISD / OSA 2 DUCTED
More informationLennox Mini-Split Systems Year-Round Comfort and Performance
Lennox Mini-Split Systems Year-Round Comfort and Performance Single- and Multi-Zone Heat Pump Systems UP TO 24.0 SEER AND 11.0 HSPF The solution that works where others won t. LENNOX MINI-SPLIT AT A GLANCE:
More informationAIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University
AIR-CONDITIONING SYSTEMS AND APPLICATIONS Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS Earliest air conditioning system used only for heating (winter) Provided heated air for comfort
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationInstructors: Contact information. Don Reynolds Doug McGee Factory Tech Support
Contact information Instructors: Don Reynolds 616-560-9903 Doug McGee 517-294-3932 Factory Tech Support 888-593-9988 Product Improvements for 2017 Todays Objectives Job Site Information Sheets Low Ambient
More informationSnohomish County PUD #1 HEAT PUMP SYSTEM INSTALLATION STANDARDS
Snohomish County PUD #1 HEAT PUMP SYSTEM INSTALLATION STANDARDS April 2018 Topic TABLE OF CONTENTS Pages A. INTRODUCTION 5 B. DEFINITIONS 5 1. Shall 5 2. Should 5 C. CUSTOMER ELIGIBILITY 5 1. Single Family
More informationThe Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat
Producing Quality Heating & Cooling Equipment For Over 50 Years DUW/DUX SERIES 1.5 THROUGH 5 TON VERTICAL OR HORIZONTAL FAN COIL UNITS The Premium Quality Fan Coil Units for Vertical, Horizontal (Left
More informationComplete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A
Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels
More informationAppendix 13. Categories of Cooling and Heating systems
EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01
More informationPerformance Climate Changer Next generation air handler from Trane
Performance Climate Changer Next generation air handler from Trane Trane Performance Climate Changer Air Handler Two-inch, R-13 foam-injected panels with mid-span, internal thermal breaks and standard
More informationSeries PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:
RZ PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS Features: Air-cooled condenser, water-cooled condenser, or evaporative-cooled condenser packaged rooftop units from 55-240 tons Water-source
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)
(994) SPLIT-SYSTEM EVAPORATOR BLOWER K5EU090 and K4EU120 50 Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX coil
More informationProduct Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz
Product Data 50HS Single-Package Heat Pump Units 50 Hz Nominal: 7 to 18 kw (2 to 5 Tons) Single-Package Heat Pump for Manufactured Housing/Residential and Light Commercial use. Features/Benefits One-piece
More information2009 IECC Commercial Mechanical Requirements
BUILDING ENERGY CODES UNIVERSITY 2009 IECC Commercial Mechanical Requirements Ken Baker PNNL-SA-66171 Learning(Objec-ves(( ( 1. Find(minimum(equipment(efficiency(requirements( and(recite(at(least(3(common(terms(for(measuring(
More informationCWA4 Chilled & Hot Water Fan Coil
CWA4 Chilled & Hot Water Fan Coil 4-Pipe Heat & Cool Fan Coil 24,000-60,000 BTUH 259 CWA4 NOMENCLATURE BREAKDOWN 4-Pipe Heat & Cool Multiposition Fan Coil Nominal BTUH 24=24,000 36=36,000 48=48,000 60=60,000
More informationTraining Catalogue. The Unico System WITH UNICOSYSTEM.COM (800) Outlets are available in styles and finishes to match any décor.
The Unico System Training Catalogue WITH Outlets are available in styles and finishes to match any décor. UNICOSYSTEM.COM (800) 527-0896 Table of Contents I. Introduction to Unico a. Who we are... Slide
More informationTHE CARRIER COMFORT LINE
SPLIT SYSTEM SPLIT SYSTEM AIR/AIR TECH 2000 38 TUA/38 CKX 38 YCX - FB4 ASX THE CARRIER COMFORT LINE OUTDOOR UNIT THE ROAD TO All the materials used are designed and protected to resist the toughest climates:
More informationCoolSpot Engineering Guide
Engineering Guide Effective December 2017 Air-Cooled, Water-Cooled, Chilled Water or Magna Cool Precision Cooling Package Contents Contents....................................................... 2 Product
More information50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT
-1SB 018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP S W/OPTIONAL ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1997 Carrier
More informationG Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton
G Series ENCASED/UNCASED AIR COILS Geothermal/Water Source Heat Pumps R-410A Refrigerant 2- Ton Dimensional Data G Series Air Coils Installation ti Manual Installation Information Maintenance IM1018AG1
More informationRuud Achiever Series Dedicated Horizontal Package Heat Pump
Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- -SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER
More informationRuud Achiever Series Dedicated Horizontal Package Heat Pump
Package Heat Pump Ruud Achiever Series Dedicated Horizontal Package Heat Pump RQPM- 4-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] RQRM- 5/6-SEER Series Nominal Sizes 2-5 Tons [7-7.6 kw] (5 SEER/2.0 EER
More informationMODELS B1PA024, 030 AND 036
STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat
More informationWebinar: HVAC Claims Repair versus Replace Presenter: Curtis VanNess, General Manager HVAC Forensics Webinar Questions & Answers
Webinar: HVAC Claims Repair versus Replace Presenter: Curtis VanNess, General Manager HVAC Forensics Webinar Questions & Answers Q: Can you explain how a swamp cooler works and/or is different? A swamp
More informationModular Multi-position Air Handler
Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design
More information48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS
48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,
More informationSP-3. Central Air Anywhere. Flexible solutions for cooling and heating your space.
SP-3 Central Air Anywhere Flexible solutions for cooling and heating your space. The flexible alternative to conventional cooling and heating. At the close of the twentieth century, North Americans have
More informationProduct Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps
Product Data OMNIZONE 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps 18 to 60 Nominal Tons omnizonebwlogo 50BVC,E,J,K,Q020-034 SINGLE PIECE OMNIZONE
More informationGeneral HVAC Recommendations
General HVAC Recommendations DESIGN GUIDELINES FOR ENERGY EFFICIENT HVAC SYSTEMS Thank you for your interest in energy efficiency! Energy efficient heating, ventilation, and air conditioning (HVAC) equipment
More informationEHH SERIES DRAW THROUGH FAN COILS CFM
EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE
More informationVERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN
VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-019 TABLE OF CONTENTS DESIGN & SPECIFICATIONS...3 APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL DATA... 5 SPECIFICATIONS...
More information