Center of Competence Refrigeration and Air conditioning

Size: px
Start display at page:

Download "Center of Competence Refrigeration and Air conditioning"

Transcription

1 k Center of Competence Refrigeration and Air conditioning Information sheet air handling unit Basic requirements The unit which should be tested has to be delivered completely with all necessary equipment. An operation manual, an electrical wiring diagram, and sufficient sealing and connection material has to be provided also with the unit. The unit should be mounted on an one-piece basic frame and should have a facility to move the unit with a crane. If this is not possible, the one-piece basic frame should be delivered separate to the unit and the parts of the air handling unit should be provided with a facility to move them with a crane. The maximal height of the air handling unit should not exceed 2,2 m (inclusive the basic-frame and the facility to move the unit with a crane). The unit has to be delivered with a complete electrical connection (repair switch, plug and if necessary with a frequency transformer). WRG Example for a unit with cooler, heater and heat recovery system page 1 of 9 Issue: 07/ 2010

2 Test of the mechanical performance The following mechanical performance has to be tested on the real unit: leakage of the casing - bypass- leakage casing strength Therefore two covers for each air side (e.g. sheet metal) and sealing material has to be provided. These covers should be equipped with a pipe ( o 6 mm, length min. 25mm) for the measuring of the internal pressure of the casing and a pipe ( i 105 mm, length min. 150 mm) in order to connect the unit to our leakage test facility. For units with a heat recovering system please take into account that we need the above mentioned covers for the exhaust side to. pipe ( 6 mm) HRS + - pipe i 105 mm Example for covers Seite 2 von 9 Stand: 07/ 2010

3 Air volume flow rate test The air volume flow rate of the unit will be tested with an orifice plate test stand. From the air volume flow rate test stand Transition piece Example of the test set-up for the air volume flow test For the adjustment of the unit to our air volume flow test stand it is necessary that the manufacturer delivers the following transition pieces with the unit. Supply air inlet: 625 mm 1 Transition piece according to the sketch, fitting to the below described duct 1 Duct with the dimensions of the entrance of the unit (length 1 m) with wall pressure tapping Supply air outlet: 1 Duct with the dimensions of the entrance of the unit (length 1 m) with wall pressure tapping and a downstream connected damper (with the possibility to adjust and lock from the outside). Seite 3 von 9 Stand: 07/ 2010

4 Capacity test (cooler / heater) To carry out the capacity test on a cooler/heater it is necessary that the manufacturer delivers the following transition pieces and additional equipment with the unit: 1 x siphon for a controlled drain of the condensate (only for cooling capacity tests). 2 x Fitting transition pieces for the water connection to the cooler/heater (inlet/outlet) in order to connect the cooler/heater to our test facility. Connection of the coil/ heater) Transition piece with o = 2 and a threat (outside) pipe: length min. 10 x ø Transition pieces for the air side of the unit in order to connect the unit to our test facility(see sketch). Supply air inlet: 620 mm 1Transition piece according to the sketch, fitting to the below described duct 1 Duct with the dimensions of the entrance of the unit (length 1 m) with wall pressure tapping Seite 4 von 9 Stand: 07/ 2010

5 Supply air outlet: 1 Duct with the dimensions of the entrance of the unit (length 1 m) with wall pressure tapping and a downstream connected damper (with the possibility to adjust and lock from the outside) 620 mm 1 Transition piece according to the sketch, fitting to the below described duct (damper) Test of the heat recovery system To carry out the capacity test on the heat recovery system of the unit it is necessary that the manufacturer delivers the following transition pieces and additional equipment with the unit: Transition pieces for the air side of the unit in order to connect the unit to our test facility (see sketch). Seite 5 von 9 Stand: 07/ 2010

6 Supply/ Exhaust air inlet: 620 mm 2 Transition pieces according to the sketch, fitting to the below described duct 2 Ducts with the dimensions of the entrance of the unit (length 1 m) with wall pressure tapping Supply/ Exhaust air outlet: 2 Ducts with the dimensions of the entrance of the unit (length 1 m) with wall pressure tapping and a downstream connected damper (with the possibility to adjust and lock from the outside) 620 mm 2 Transition pieces according to the sketch, fitting to the below described duct (damper) Seite 6 von 9 Stand: 07/ 2010

7 Induct sound power For the determination of the induct sound power the unit will be built into a chamber. The air outlet of the unit is in the level of the door of the chamber. Chinks between the unit and the door of the chamber are sealed with sound reducing material. The air volume flow of the unit will by adjusted be closing the air inlet damper of the unit. The sound power level is determined at an appropriate measuring surface. Only the induct sound power of the supply side is measured. Measuring surface for the determination of the in duct sound power Example for the test set-up of the induct sound power Seite 7 von 9 Stand: 07/ 2010

8 Airborne sound power The unit will be placed in a free field. On the inlet and outlet of the supply side of the unit sound attenuators will be mounted. The attenuators have to be provided by the manufacturer. The connection between the sound attenuators and the air handling unit has to be suitable and easy to install. Necessary additional equipment for the fixing of the attenuators have to be provided by the manufacturer. During the airborne sound power measurement only the supply side is working. Measuring surface for the determination of the airborne sound power Support (delivered by manufacturer Example for the test set-up of the airborne sound power Seite 8 von 9 Stand: 07/ 2010

9 Important: All above mentioned equipment has to be delivered with the air handling unit at the same time to the test house. The missing equipment will be procured by TÜV Süd Industrie Service. The procuring of these equipment (material and working time) and through it caused waiting periods will be separately be charged by TÜV Süd Industrie Service. The hourly laboratory wage come to 129 Euro/h. The units have to be delivered and picked up at the laboratory without costs for TÜV Süd Industrie Service. Eventually necessary costs for customs clearance will be charged separately by TÜV Süd Industrie Service. Delivery address: TÜV SÜD Industrie Service Center of Competence für Kälte- und Klimatechnik Ridlerstraße München Contact person: Dipl.-Ing. (FH) Thomas Bichler phone.: fax.: internet: (search for: air conditioning) Seite 9 von 9 Stand: 07/ 2010

R E P O R T W R G D I N E N

R E P O R T W R G D I N E N R E P O R T W R G 4 4 3 D I N E N 1 3 1 4 1-7 Test laboratory Test object Customer Scope of assignment Date of receipt of test object TÜV SÜD Industrie Service GmbH Center of Competence for Refrigeration

More information

R E P O R T D I N E N

R E P O R T D I N E N R E P O R T W R G 3 9 6 D I N E N 1 3 1 4 1-7 Test laboratory Test object Customer Scope of assignment TÜV SÜD Industrie Service GmbH Center of Competence for Refrigeration and Air Conditioning Air Conditioning

More information

Modular air-handling units

Modular air-handling units Modular air-handling units AHU N 12.10.002 Range AeroMaster XP Cirrus Modular air-handling units Why AeroMaster XP? The latest knowledge from field of projection, production and operation of air-handling

More information

TSEK VHR EC HEAT RECOVERY UNITS

TSEK VHR EC HEAT RECOVERY UNITS TSEK EC HEAT RECOVERY UNITS TS EN ISO 9001:2008 SN: 01 100 901925 General Information TSEK VENCO Heat Recovery Ventilation Units () are designed for saving energy and also improving indoor air quality.

More information

Heat Recovery Units. Heat Recovery 1

Heat Recovery Units. Heat Recovery 1 Heat Recovery Units Heat Recovery 1 Heat Recovery Unit Why? A heat recovery unit (HRU) can help make mechanical ventilation more cost effective by reclaiming energy from exhaust airflows. HRUs use air-to-air

More information

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing Field of application Description Advantages Range Technical details Installation Remote controls Servicing Remote control ErP * ** Conpliance compliance. ErP ready. Advantages Reversible connections. Ventilation

More information

Acoustic Verification Report

Acoustic Verification Report Acoustic Verification Report Invacare XPO 2 Portable Oxygen Concentrator Type XPO100B-EU for Date: 2013-12-10 Our reference: IS-ATC2-MUC/js Document: Report Invacare VR.600010074.002.12 - Revision 2.docx

More information

KN-KWL 110 SE-EC Kontrollierte Wohnraumlüftung KN

KN-KWL 110 SE-EC Kontrollierte Wohnraumlüftung KN KN-KWL 110 SE-EC Kontrollierte Wohnraumlüftung KN 2014-07 Druck-, Satzfehler und techn. Änderungen vorbehalten - Subject to change Seite 1 2014-07 Druck-, Satzfehler und techn. Änderungen vorbehalten -

More information

Climate Control System

Climate Control System Page 1 of 13 SECTION 412-00: Climate Control System General Information DESCRIPTION AND OPERATION 1998 Mark VIII Workshop Manual Climate Control System Cautions and Warnings WARNING: To avoid accidental

More information

COMMERCIAL ENERGY SAVINGS GUIDE

COMMERCIAL ENERGY SAVINGS GUIDE COMMERCIAL ENERGY SAVINGS GUIDE www.touchstoneenergy.com/bea www.touchstoneenergy.com/bea USING ENERGY MORE EFFICIENTLY IMPROVES YOUR BOTTOM LINE. Cooperatives and their commercial members share a common

More information

Instructions for the BASIC Air Handling System, Sizes General 1.1 Description of the System

Instructions for the BASIC Air Handling System, Sizes General 1.1 Description of the System Instructions for the BASIC Air Handling System, Sizes 004 055 1. General 1.1 Description of the System The BASIC System is a complete modular air handling unit. The unit consists of blocks, i.e. a number

More information

A MEMBER OF MUHIBBAH ENGINEERING

A MEMBER OF MUHIBBAH ENGINEERING CiBAS The CiBAS is an innovative and unique WHRU designed by CiTECH, specifically aimed at saving weight and space. With over 70 units in operation, it is an ideal environmentally friendly solution for

More information

Separating Ventilation and Temperature Regulation

Separating Ventilation and Temperature Regulation P r e s s R e l e a s e Separating Ventilation and Temperature Regulation Kampmann GmbH has a new concept for compliance with the 2009 Energy-Saving Directive (EnEV), 15: Users and the environment will

More information

A MEMBER OF MUHIBBAH ENGINEERING

A MEMBER OF MUHIBBAH ENGINEERING CiBAS The CiBAS is an innovative and unique WHRU designed by CiTECH, specifically aimed at saving weight and space. With over 70 units in operation, it is an ideal environmentally friendly solution for

More information

CONTENTS. Page 1. THE DRYPAC SYSTEM - CUSTOM MADE 1 2. PRINCIPLE OF OPERATION 2 3. CONTROLS 4 4. FLEXIBILITY 6 5. DRYPAC OPTIONS 7

CONTENTS. Page 1. THE DRYPAC SYSTEM - CUSTOM MADE 1 2. PRINCIPLE OF OPERATION 2 3. CONTROLS 4 4. FLEXIBILITY 6 5. DRYPAC OPTIONS 7 CONTENTS Page 1. THE DRYPAC SYSTEM - CUSTOM MADE 1 2. PRINCIPLE OF OPERATION 2 3. CONTROLS 4 4. FLEXIBILITY 6 5. DRYPAC OPTIONS 7 6. CONSTRUCTION / MATERIALS 8 7. DIMENSIONS 8 8. LAYOUT 12 9. PRINCIPLE

More information

Gemini EC. Engineered with Excellence, Specified with Confidence All-in-One Renewable Energy Climate Control

Gemini EC. Engineered with Excellence, Specified with Confidence All-in-One Renewable Energy Climate Control Gemini EC 1000-12000 All-in-One Renewable Energy Climate Control - Integral Aerothermal fresh air source heat pump boiler - Integral dual function dehumidifying and expelled room air heat pump - Direct-Contact

More information

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume

COMMERCIAL HVAC PACKAGED EQUIPMENT. Rooftop Units Level 1: Constant Volume COMMERCIAL HVAC PACKAGED EQUIPMENT Rooftop Units Level 1: Constant Volume Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application

More information

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery Datasheet For part no. and prices: see pricelist VITOVENT 300-F Mechanical ventilation system with heat recovery for demanddependent

More information

Air Handling Units. T F E.

Air Handling Units.  T F E. Air Handling Units Extract from BS EN ISO 15138:2007 Petroleum & natural gas industries- Offshore production installations-heating, ventilation & air-conditioning. A.12.1 Function Installations provided

More information

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Trane Performance Climate Changer Air Handlers. An air handler for every need. Trane Performance Climate Changer Air Handlers An air handler for every need. Trane Performance Climate Changer air handlers: designed to optimize your HVAC system. Trane Performance Climate Changer air

More information

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION Ultra high performance Environmentally friendly with heat recovery solutions Optimised performance thanks to the control system Air flowrate: 1500 to 6000 m 3 /hr and a compact 400 mm profile Available

More information

HEAT RECOVERY UNITS TSEK. Mech-Elec, 41, Hawthorn Road, Western Ind. Est., Dublin 12 Tel:

HEAT RECOVERY UNITS TSEK. Mech-Elec, 41, Hawthorn Road, Western Ind. Est., Dublin 12 Tel: HEAT RECOVERY UNITS TSEK Mech-Elec,, Hawthorn Road, Western Ind. Est., Dublin Tel: +-- 88 E-Mail: info@mech-elec.ie Mech-Elec UK, Unit, Bretts Farm, Romford Road, Aveley, Essex, RM XD. Tel: +--879 E-Mail:

More information

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance. 77 Do not install the condensate assembly if a component is lost or missing. Replace the entire assembly. Failure to follow this warning could result in property damage, serious personal injury, or death.

More information

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return Single Zone System One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return Multi Zone System Used in small to medium sized buildings

More information

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1: 4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XRT INSTALLATION AND OPERATION MANUAL BOOK 1 OVERVIEW ABOUT BOOK 1: This

More information

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0 Residential/commercial units selection program: http://salda.lt/en/selection/ahu AmberAir Compact units selection program VentMaster: http://salda.lt/en/pros/category/download_page/ WWW.SALDA.LT Rotor

More information

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section

More information

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001 This HAP e-help provides a high-level overview of induction beams, how they work and how to model them in HAP 4.8 (and later versions). The first half of the article explains how induction beams work.

More information

39G Air Handling Unit

39G Air Handling Unit 39G Air Handling Unit Air flow: 2000 ~ 60000 m³/h The Manufacturer reserves the right to change any produt specifications without prior notices Version: Supersede: Effective Date: CAT_39G_E-1307_02 CAT_39G_E-1205_01

More information

Compact. Efficient. TROX.

Compact. Efficient. TROX. Compact. Efficient. TROX. The art of handling air TROX is the leader in the development, manufacture and sale of components and systems for the ventilation and air conditioning of rooms. With 24 subsidiary

More information

Liquid desiccant dehumidification systems. Product guide

Liquid desiccant dehumidification systems. Product guide Liquid desiccant dehumidification systems Product guide Advanced dehumidification systems Economic value comparison Performance guarantee Leading liquid desiccant technology Alfa Laval Kathabar dehumidification

More information

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available. PART 1: GENERAL 1.01 General Requirements A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the

More information

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units PAGE 1/32 Summary This document (_r2) updates the previous one (_r1) issued on Mar 08. Revised items are identified by using: 2 (1 Location). This Advanced Products News introduces the new line-up of KPI-(502~2002)E1E

More information

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made.

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made. Dryer Section All Paper Grades Press Release How can the efficiency of the T. Bock (Dipl.-Ing.), Manager Application & Technical Service, Heimbach GmbH & Co. KG, thomas.bock@heimbach.com I. Durniok (Dipl.-Ing.),

More information

Certified Passive House Component For cool, temperate climates, valid until 31 December 2017

Certified Passive House Component For cool, temperate climates, valid until 31 December 2017 Certificate Certified Passive House Component For cool, temperate climates, valid until 31 December 2017 Category: Manufacturer: Product name: Heat recovery unit DencoHappel GmbH 44625 Herne, GERMANY Series

More information

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV

ClearFire Economizer Model ECF Integral or External. Addendum to manuals CFH and CFV ClearFire Economizer Model ECF Integral or External Addendum to manuals 750-295 CFH and 750-269 CFV CB-8466 08/2011 1-GENERAL The Model ECF economizer is a stainless steel coil tube arrangement using

More information

Pharmaceutical Facility Design

Pharmaceutical Facility Design PhEn-602 Pharmaceutical Facility Design J. Manfredi Notes 9A PhEn-602 J. Manfredi 1 Primary & Secondary HVAC units Primary Primary air handling unit arrangement: One unit is responsible for all of the

More information

Vallox Oy. manufactures. over LOW POWER EFFICIENCY Specific electrical

Vallox Oy. manufactures. over LOW POWER EFFICIENCY Specific electrical Vallox 150 Effect SE MLV Vallox 150 Effect SE MLV Vallox Oy manufactures Certificate No VTT-C-3514-08 Translation 1 (2) ventilation units Vallox 150 Effect SE MLV (preheating with ground heat) Vallox 150

More information

Compact. Efficient. TROX.

Compact. Efficient. TROX. Compact. Efficient. TROX. The art of handling air TROX understands the art of handling air like no other company. Since its foundation in 1951, TROX has been developing and manufacturing sophisticated

More information

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline ME 414/514 HVAC Systems Overview Equipment Outline 2-1 The Complete System 2-2 The Air-Conditioning and Distribution System 2-3 Mechanical Equipment Air-handling Equipment Heating Equipment Boilers Furnaces

More information

Small Room Heat Recovery Ventilation

Small Room Heat Recovery Ventilation Small Room Heat Recovery Ventilation Ideal for smaller spaces that would benefit from heat recovery, such as staff rooms or offices Version 3.1 2 Breathing Buildings Small Room Heat Recovery 3 Small Room

More information

Sub-Critical Operation of the CO2 Expander/ Compressor

Sub-Critical Operation of the CO2 Expander/ Compressor Purdue University Purdue e-pubs International Compressor Engineering Conference School of Mechanical Engineering 2006 Sub-Critical Operation of the CO2 Expander/ Compressor Josef Riha Technical University

More information

APPLICATION, INSTALLATION, AND MAINTENANCE MANUAL CA2XRT, CA3XRT, CA4XRT

APPLICATION, INSTALLATION, AND MAINTENANCE MANUAL CA2XRT, CA3XRT, CA4XRT 4510 Helgesen Drive, Madison, WI 53718 (608) 221-4499, (800) 627-4499, Fax: (608) 221-2824 support@renewaire.com www.renewaire.com APPLICATION, INSTALLATION, AND MAINTENANCE MANUAL CA2XRT, CA3XRT, CA4XRT

More information

DADANCO E U R O P E. Induction unit. Installation, operation & maintenance manual. Induction Units

DADANCO E U R O P E. Induction unit. Installation, operation & maintenance manual. Induction Units DADANCO Induction unit Installation, operation & maintenance manual Induction Units DADANCO INDUCTION UNIT FLOOR-MOUNTED MODELS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS DESCRIPTION FMLBY floor

More information

Comfort Series. Energy Recovery Ventilator. Why Fresh Air Ventilation is Vital for Today s Energy-Efficient Homes

Comfort Series. Energy Recovery Ventilator. Why Fresh Air Ventilation is Vital for Today s Energy-Efficient Homes Comfort Series Energy Recovery Ventilator Why Fresh Air Ventilation is Vital for Today s Energy-Efficient Homes LEED Certification Points Carrier, the world s leader in high technology heating, air conditioning

More information

GFD. GVD V-shape coil condenser. Güntner Info. 8 additional basic models for container transport!w. V-shape coil drycooler

GFD. GVD V-shape coil condenser. Güntner Info. 8 additional basic models for container transport!w. V-shape coil drycooler Güntner Info GFD V-shape coil drycooler GVD V-shape coil condenser also available with HydroSpray system 75 kw 2 MW 8 additional basic models for container transport!w Customized solutions for every application

More information

HRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series

HRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series AKOR BP HR Series AKOR BP HR Energy recovery ventilation systems for single dwelling houses or multi-dwelling blocks, with crossflow heat exchanger. It guarantees continuous air replacement in single dwelling

More information

GreenMaster HP Exhaust air heat pump for residential properties

GreenMaster HP Exhaust air heat pump for residential properties GreenMaster HP Exhaust air heat pump for residential properties Air-Site We are a Swedish company that likes air and energy recovery. That's why we develop products that use air to heat, cool and provide

More information

Technical Assignment 1

Technical Assignment 1 0 Technical Assignment 1 ASHRAE Standard 62.1 Ventilation and Standard 90.1 Energy Design Evaluations Compliance Analysis David H. Koch Institute for Integrative Cancer Research Massachusetts Institute

More information

Heat recovery unit RDKS

Heat recovery unit RDKS Heat recovery unit RDKS Heat recovery unit RDAS is based on our RDAR unit and develops this further. The unit has a rotary heat exchanger with stepless speed control. This allows for very precise temperature

More information

Trane Performance Climate Changer Air Handlers. An air handler for every need.

Trane Performance Climate Changer Air Handlers. An air handler for every need. Trane Performance Climate Changer Air Handlers An air handler for every need. Trane Performance Climate Changer air handlers: The most comprehensive air-handler portfolio in the industry. The portfolio

More information

Technical documentation Comfort domestic ventilation system

Technical documentation Comfort domestic ventilation system Technical documentation Comfort domestic ventilation system CWL Excellent CWL-T Excellent CWL-F Excellent 2 CWL unit options Type CWL-F-150 Excellent CWL-F-300 Excellent CWL-180 Excellent CWL-300 Excellent

More information

Drying Tumblers Pound Capacity

Drying Tumblers Pound Capacity Drying Tumblers 25-170 Pound Capacity Preventative Maintenance Please refer to your operating manual for detailed maintenance procedures. www.comlaundry.com Part No. 70323301R6 December 2009 Table of

More information

GENERAL CAPABILITIES

GENERAL CAPABILITIES GENERAL CAPABILITIES Reliable Process Heating Solutions HEAT EXCHANGE AND TRANSFER, INC. 500 Superior Street Carnegie, PA 15106 Phone 412-276-3388 Fax 412-276-3397 www.heat-inc.com FROM CONCEPT TO COMPLETION,

More information

Residential Duct Mount Builder s Box Media Air Cleaner

Residential Duct Mount Builder s Box Media Air Cleaner INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Residential Duct Mount Builder s Box Media Air Cleaner Part Numbers: P102-BB14A, P102-BB20 IMPORTANT: Read entire instructions before installing the

More information

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option. Air handling units Aesthetic Not to add significantly to the existing ambient noise levels. Functional requirements If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally

More information

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL

More information

SECTION AIR COILS

SECTION AIR COILS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

AT4 Hygienic Application According to Guideline VDI 6022

AT4 Hygienic Application According to Guideline VDI 6022 Air-handling-units AT4 Hygienic Application According to Guideline VDI 6022 AT4 AHU for hygienic application The VDI guideline 6022, part 1 and 3 defines the hygienic requirements for AHU with regard to:

More information

The Book of AERMEC NRL Sequence of Operation

The Book of AERMEC NRL Sequence of Operation The Book of AERMEC NRL Sequence of Operation Heating and cooling operation. 2 Sequence of operation Aermec air to water chiller/heat pump use Hydronic s in conjunction with refrigerant to provide heating

More information

Assessment Schedule - TS8

Assessment Schedule - TS8 The Assessor shall determine the business s commitment and support to good and safe working practices; also that it has a positive culture in all aspects of its work. In particular, the assessor shall

More information

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance Installation Operation Commissioning Maintenance HOT AIR GENERATOR WITH GAS BURNER GGS NA11.45 A 06-2011 04-2011 CONTENTS 1. DESCRIPTION OF THE UNIT 2. INSTALLATION & CONNECTION 3. COMMISSIONING 4. CARE

More information

Energy Recovery Ventilator

Energy Recovery Ventilator Energy Recovery Ventilator LG Electronics www.lg.com http://partner.lge.com Distributed by Copyright 2015 LG Electronics. All rights reserved. 2015 Eco_V Energy Recovery Ventilator Heat Exchanger Bypass

More information

VEX100 series Air handling units with cross-flow heat exchanger

VEX100 series Air handling units with cross-flow heat exchanger Product information - Version 6 VEX100 series Air handling units with cross-flow heat exchanger VEX140: 400-2200 m 3 /h VEX150: 700-3600 m 3 /h VEX160: 1100-5000 m 3 /h VEX170: 1400-8400 m 3 /h Contents

More information

11.4 Component Assembly Diagrams and Parts Lists Case Assembly

11.4 Component Assembly Diagrams and Parts Lists Case Assembly .4 Component Assembly Diagrams and Parts Lists.4.1 Case Assembly 1 5 4 6 7 8 70 Appendixes # Description Part # Remark 1 Intake Air Duct Assembly 000866B Exhaust Pipe Assembly 000867A Case 00775A 4 Intake

More information

MLM. Multi-Layer Media for Regenerative Thermal Oxidizers. from Lantec Products Installation Manual

MLM. Multi-Layer Media for Regenerative Thermal Oxidizers. from Lantec Products Installation Manual MLM Multi-Layer Media for Regenerative Thermal Oxidizers from Lantec Products Installation Manual 1. Introduction Contents 1. Introduction 2. Safety First 3. Media Inspection on Arrival 4. Proper Handling

More information

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs Custom Units to Meet Your Unique Design Needs Engineered for flexibility and performance Contents Horizontal Configuration....1 Horizontal with Standard Economizer Configuration...2 Stacked Configuration...3

More information

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Topvex SoftCooler TR. Specification data

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Topvex SoftCooler TR. Specification data Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Topvex SoftCooler TR Specification data 2 Topvex SoftCooler TR Comfort cooling, ready from factory

More information

ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU) TECHNICAL DATA RIGHT VIEW TOP VIEW

ErP - COMPLIANT TO EUROPEAN DIRECTIVE VENTILATION UNITS (AHU) TECHNICAL DATA RIGHT VIEW TOP VIEW BSK 1/5 RIGHT VIEW TOP VIEW GENERAL SPECIFICATIONS Supply Air Flow Return Air Flow Frame Dimensions (mm) 6,000 m³/h 6,000 m³/h 25 steel profile A2608 x H2723 x L4789 Supply Air Velocity Return Air Velocity

More information

COMcheck Software Version Mechanical Compliance Certificate

COMcheck Software Version Mechanical Compliance Certificate COMcheck Software Version 3.8.2 Mechanical Compliance Certificate 90.1 (2007) Standard Section 1: Project Information Project Type: New Construction Project Title : Rudy's Star Motors Construction Site:

More information

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements. SECTION 15855 AIR HANDLING UNITS WITH COILS PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Central Station Air Handling Units. B. Related Sections: 1.02 REFERENCES 1. Section 15010 - Basic Mechanical

More information

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1: 4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XIN INSTALLATION AND OPERATION MANUAL BOOK 1 OVERVIEW ABOUT BOOK 1: This

More information

Standard Features. Performance/Capacities

Standard Features. Performance/Capacities TSC-66 Traditional Power/Connections Approximate Total Load AMPS 208V / 60HZ / 3PH 51.8 208V / 60HZ / 1PH 88.3 230V / 60HZ / 3PH 47.8 230V / 60HZ / 1PH 81.5 460V / 60HZ / 3PH 23.9 Booster Heater Options

More information

Air Distribution Fan and Outside Air Damper Recycling Control

Air Distribution Fan and Outside Air Damper Recycling Control building science.com 2008 Building Science Press All rights of reproduction in any form reserved. Air Distribution Fan and Outside Air Damper Recycling Control Research Report - 0991 5-July-1999 Armin

More information

1998 Expedition/Navigator Workshop Manual

1998 Expedition/Navigator Workshop Manual Page 1 of 8 SECTION 412-00: Climate Control System - General Information 1998 Expedition/Navigator Workshop Manual DESCRIPTION AND OPERATION Procedure revision date: 02/11/2000 Climate Control System WARNING:

More information

CERTIFICATE of QUALITY TEST

CERTIFICATE of QUALITY TEST Testing laboratory for climatic, mechanical and corrosive environmental stress CERTIFICATE of QUALITY TEST Test report - No. 10142 / 13 Client ADDI-DATA GmbH Airpark Business Center Airport Boulevard B210

More information

KOMFORT EC DB Suspended heat recovery air handling units

KOMFORT EC DB Suspended heat recovery air handling units 2018 AIR HANDLING UNITS KOMFORT EC DB Suspended heat recovery air handling units Features Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings.

More information

100% Outdoor Air Dehumidification Methods

100% Outdoor Air Dehumidification Methods Technical Bulletin 16 100% Outdoor Air ehumidification Methods I NTROUCTION As consulting engineers and end users implement the ASHRAE 6 ventilation code, they are faced with selecting an appropriate method

More information

Controlled mechanical ventilation GB 03

Controlled mechanical ventilation GB 03 RECUPER SLIM 2018 Controlled mechanical ventilation GB 03 ir conditioning Systems to install Recover... your wellbeing The home is a precious asset where we all spend a major time of your life. So it s

More information

RoofPak Applied Rooftop Systems

RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak applied rooftop systems the ideal solution

More information

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h Comfort air conditioning 76 Comfort air conditioning unit with counterflow plate heat exchanger Automatically selects the most economical operating mode! 76 13 76 01 13 with 01 - Adiabatic simplified Pro

More information

INSTALLATION DO S AND DON TS

INSTALLATION DO S AND DON TS 4.0 NOISE CONTROL Figure 4.1. - Transitions Abrupt transitions immediately adjacent to an attenuator will cause the attenuator pressure drop to increase. Ensure transitions close to attenuators are gradual

More information

Evaporative Cooling products

Evaporative Cooling products user manual Evaporative Cooling products OPERATION - MAINTENANCE Z0582995_A ISSUED 06/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT general information Note Recold

More information

Schedule of Fees Schedule B

Schedule of Fees Schedule B Schedule of Fees Schedule B BUILDING DEPARTMENT 2. Building Permit* $65.00 for value or valuation up to $1,000. After $1,000 of value $8.00 per $1,000. After $1,000,000 of value $6 per $1,000 3. Demolition

More information

HVAC Mandatory Provisions Part II, Page 1

HVAC Mandatory Provisions Part II, Page 1 HVAC Mandatory Provisions Part II, Page 1 Mandatory Equipment Efficiency Worksheet (6.4.1.1) System Equipment Type Size Category (Tables 6.8.1A through K) Sub-Category or Rating Condition Units of Efficiency

More information

Vallox Oy. manufactures ventilation units Vallox TSK Multi 80 MC. over Vallox TSK Multi 80 MC

Vallox Oy. manufactures ventilation units Vallox TSK Multi 80 MC. over Vallox TSK Multi 80 MC Vallox TSK Multi 80 MC Vallox TSK Multi 80 MC Vallox Oy manufactures ventilation units Vallox TSK Multi 80 MC Certificate No VTT-C-11032-14 Translation 1 (2) Vallox TSK Multi 80 MC is intended to be used

More information

Implementation of the Laboratory Air Handling Unit Systems (LAHU)

Implementation of the Laboratory Air Handling Unit Systems (LAHU) University of Nebraska - Lincoln DigitalCommons@University of Nebraska - Lincoln Architectural Engineering -- Faculty Publications Architectural Engineering 2003 Implementation of the Laboratory Air Handling

More information

TURBO HOODS. Product Brochure

TURBO HOODS. Product Brochure TURBO HOODS Product Brochure TABLE OF CONTENTS FUNCTIONING PRINCIPLE... 04 PRODUCT CODE... 0 PRODUCT STRUCTURE... 06 TURBOSWING GREASE FILTER... 07 EXHAUST AIR... 08 SUPPLY AIR... 09 LIGHTS... 0 DIENSIONS...

More information

Natatorium Economizer Vs. Conventional Dehumidifier

Natatorium Economizer Vs. Conventional Dehumidifier Technical Bulletin 18 Natatorium s. Conventional Dehumidifier I NTODCTION This technical bulletin will review how an economizer-type indoor pool dehumidifier functions, and provide details on its control

More information

Museum of Bavarian History Regensburg, Germany

Museum of Bavarian History Regensburg, Germany Museum of Bavarian History Regensburg, Germany Dipl.-Ing. Raphaël Vibert, Herz & Lang GmbH Key Facts Client: Public building authorities of Regensburg Architect: Wörner Traxler Richter Planungsgesellschaft

More information

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking

Smoke Control Ducts and Dampers For Single Compartment Applications. Fulfilling new requirements for EN product standards for CE Marking Smoke Control Ducts and Dampers For Single Compartment Applications Fulfilling new requirements for EN product standards for CE Marking New Smoke Control Product Range Fläkt Woods Smoke Control Ducts and

More information

Insty-Pac Steam Humidifiers

Insty-Pac Steam Humidifiers IP-1 Insty-Pac Steam umidifiers The PURE umidifier Co. Insty-Pac (patent no. 6,065,740) steam injection humidifier is jobengineered to assure highly efficient steam release into the air stream. Each humidifier

More information

Mold/Moisture Control Case Study

Mold/Moisture Control Case Study Mold/Moisture Control Case Study Presented by Boggarm S. Setty, P.E., FASHRAE Setty & Associates, Ltd. www.clima2005.ch Clima 2005 Lausanne Solothurnstrasse 13 CH-3322 Schönbühl Switzerland th 8 REHVA

More information

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S Heat and Energy Recovery Ventilators 2018 AIR HANDLING UNITS 2 CONTENT KOMFORT EC S5B270(-E) 4 KOMFORT EC D5B1(-E) 8 KOMFORT EC S(B)(-E) 12 AIR HANDLING UNITS

More information

CONTENTS DE-HUMIDIFICATION IN INDOOR SWIMMING POOLS 2 DESIGN PROPERTIES OF THE INDOOR POOL DE-HUMIDIFYING UNIT 4 FRAME STRUCTURE 6 PANEL STRUCTURE 6

CONTENTS DE-HUMIDIFICATION IN INDOOR SWIMMING POOLS 2 DESIGN PROPERTIES OF THE INDOOR POOL DE-HUMIDIFYING UNIT 4 FRAME STRUCTURE 6 PANEL STRUCTURE 6 INDOOR POOL INDOOR POOL CONTENTS DE-HUMIDIFICATION IN INDOOR SWIMMING POOLS 2 DESIGN PROPERTIES OF THE INDOOR POOL DE-HUMIDIFYING UNIT 4 FRAME STRUCTURE 6 PANEL STRUCTURE 6 DRAINAGE SYSTEM 7 OUR DISTINCTIONS

More information

ducted / recirculating separately 2.1 WS / 11.8 HS 3-stage Rear Yes (600 CFM options sold separately) 29 3/8" x 31" x 2 3/4" 6" or 8"

ducted / recirculating separately 2.1 WS / 11.8 HS 3-stage Rear Yes (600 CFM options sold separately) 29 3/8 x 31 x 2 3/4 6 or 8 HDD80050UC Stainless Steel Sleek, built-in, and retracts out of sight. Bosch 30" Downdraft's flexible design seamlessly integrates into your kitchen Features & Benefits Beautifully designed to preserve

More information

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit

CLIMACIAT. air HanDLIng UnIT: CLIMaCIaT. Air handling unit AHU for all applications Designed to meet the EN 13053 and EN 1886 standards The effective solution for service sector, industry and healthcare applications air HanDLIng UnIT: CLIMaCIaT represents the

More information

The world s first batch annealing plant with fully automatic crane operation ensures optimal use of energy

The world s first batch annealing plant with fully automatic crane operation ensures optimal use of energy Internet-PDF aus MPT (2015), Heft 3, Seite 136 141. Verlag Stahleisen GmbH, Düsseldorf. The new batch annealing plant at Bilstein comprises twelve bases; any hood fits on any free base The world s first

More information

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS AND APPLICATIONS Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS Earliest air conditioning system used only for heating (winter) Provided heated air for comfort

More information

Compact VERTICAL FLAT. Compact. Condensers GCHC/GCVC for HFCs, NH 3

Compact VERTICAL FLAT. Compact. Condensers GCHC/GCVC for HFCs, NH 3 INFO FLAT Compact VERTICAL Compact Condensers GCHC/GCVC for HFCs, NH 3, Propane Gas coolers GGHC/GGVC for Fluid coolers GFHC/GFVC for water/glycol and other media 4 400 kw Compact design ideal for commercial

More information